LER 1977-251-07 for Turkey Point, Unit 4 - Pressurizer Heatup Rate
ML18227A510
Person / Time
Site: Turkey Point  NextEra Energy icon.png
Issue date: 09/06/1977
From: Schmidt A
Florida Power & Light Co
To: O'Reilly J
NRC/IE, NRC/RGN-II
References
LER 1977-251-07
Download: ML18227A510 (2)


Text

P. O. BOX 013100, MIAMI, FL 33101 FLORIDA POWER & LIGHT COMPANY

/0 g5/

Mr. James P. O'Reilly, Director, Region Office of Inspection and Enforcement II U. S. Nuclear Regulatory Commission 230 Peachtree Street, N.W., Suite 1217 Atlanta, Georgia 30303

Dear Mr. O'Reilly:

REPORTABLE OCCURRENCE: 251-77-7 TURKEY POINT UNIT 4 DATE OF OCCURRENCE: AUGUST 22, 1977 PRESSURIZER HEATUP RATE The attached Licensee Event Report is being submitted in accordance with Technical Specification 6.9.2 to provide prompt notification of the subject occurrence.

Very truly yours, A. D. Schmidt Vice President Power Resources MAS/ms Attachment cc: Robert Lowenstein, Esquire Director, Office of Inspection and, Enforcement (40)

Director, Office of Management Information and Program Control gP (3)

I ILL I '0'4JL Le I V I I '4 I I 1I I LJVl I CONTROL BLOCK: SE PRINT ALL REQUIRED INFORMATIOM7 1

UCENSEE LCENSE EVENT NAME LICENSE NUMBER TYPE TYPE 31 F L T P S 4 0 0 0 00, 00 0 4 1 1 1 1 ~01 89 14 15 25 26 30 31 32 REPORT REPORT CATEGORY TYPE SOURCE ~

DOCKET NUMSER ~ EVENT DATE REPORT DATE

)+100M'T~ ~2 L 0 5 0 0 5 1 0 2 2 2 7 7 0 9 0 6 7 7 8 57 58 59 60 61 68 69 74 75 80 EVENT DESCRIPTION lg Westin house notified FPL that the correct maximum allowable heatu rate for the res-8 9 80 l3 DI surizer is 100' hr instead of the currentl allowed 200' hr Tech S ec 3.1.2.d 80 0

8 9 80 ig heatup rate and can not do so in any normal evolution. Corrective action was discussed 80 2

8 9 (251-77-7) 80 SYSTEM CAUSE COMPONENT CODE CODE COMPONENT CODE MANUFACIUfKA Q7 ~CB ~C V E S S E L W 1 2 0 N 8 8 10 11 12 17 44 47 CAUSE OESCRIPTION

~QS NA 8 9 80 8 9 80 89 METHOD OF 80 STATUS X POWER OTHER STATUS DISCOVERY OSCOVERY DESCRIPTION l7~ ~E ~10 o NA D Westinghouse letter FPL-77-62 (8/18/7 )

'8 9 FORM OF 10 12 13 44 45 46 80 ACTIVITY COATENT l~

RELEASEO OF RELEASE AMOUNT OF ACTIVITY LOCATION OF RELEASE Qs ~z ~z NA NA

0 9 10 11 44 45 80 PERSONNEL EXPOSURES NUMBER TYPE DESCRIPTION NA 89 11 12 13 80 PERS'ONNEL INJURIES NA t 80 PROBABLE CONSEQUENCES NA 89 80 LOSS OR OAMAGE TO FACIUTY TYPE DESCRIPTION 6Q Z NA EE 89 10 80 PUBLICf!Y NA 89 80 AOOITIONAL FACTORS NA 80 89 80 A K OS/552-3820