ML18120A027

From kanterella
Jump to navigation Jump to search
8 to Fire Hazards Analysis Report (Fhar) Vol. 2. Attachment 3-8
ML18120A027
Person / Time
Site: Crane Constellation icon.png
Issue date: 04/06/2018
From:
Exelon Generation Co
To:
Office of Nuclear Reactor Regulation
Shared Package
ML18117A343 List: ... further results
References
TMI-18-047
Download: ML18120A027 (7)


Text

Attachment 3-8 Page 1 Appendix R Emergency Lights FHAR3-8.doc Rev. 27 Tag No Building Note 1 Elevation Note 2 Fire Zone or Area Note 3 Location Equipment or Area Being Illuminated Note 4 Number of Lamps FHAR Drawing 1-FHA-EL-L-1 AB 281 AB-FZ-4 North Stairway A/E North Stairs 2

026 EL-L-2 FHB 281 FH-FZ-1 South Stairway A/E South Stairs 2

026 EL-L-3 FHB 305 FH-FZ-2 South Stairway A/E South Stairway 2

027 EL-L-4 FHB 331 FH-FZ-2 South Stairway A/E South Stairway 2

028 EL-L-5 DGB 305 DG-FA-1 Diesel Generator 'A' Room EDG A 2

044 EL-L-6 DGB 305 DG-FA-2 Diesel Generator 'B' Room EDG B 2

044 EL-L-7 IB 305 IB-FZ-5 Hallway - North Wall A/E Hallway 2

040 EL-L-8 IB 295 IB-FZ-3 Emergency Feedwater Pump 2A/2B Room

1) A/E EFW Pump Room
2) EF-V-30A, 30D 2

039 EL-L-9 IB 305 IB-FZ-5 West Stairway A/E Stairway 2

040 EL-L-10 IB 295 IB-FZ-4 Hallway - North Wall

1) A/E Hallway
2) CO-V-111B 2

039 EL-L-11 IB 305 IB-FZ-5 Hallway - North Wall Battery Box only 0

040 EL-L-11A IB 322 IB-FZ-6 Center Stairway A/E Stairway 2

041 EL-L-12 CB 306 CB-FA-1 Center Hallway A/E Hallway 2

034 EL-L-13 CB 338 FH-FZ-5 Stairway A/E Stairway 2

035 EL-L-14 CB 322 CB-FA-2B Green Switchgear Room 1E (Green) 4160 Swgr.

2 035 EL-L-15 CB 322 CB-FA-2F Red Battery Room 1A (Red) Battery Room 2

035 EL-L-16 CB 322 CB-FA-2G Green Battery Room 1B (Green) Battery Room 2

035 EL-L-17 CB 355 FH-FZ-5 Stairway A/E Stairway 2

036 EL-L-18 CB 338 CB-FA-3B Green Switchgear Room A/E 1E (Green) 4160 Swgr.

2 035 EL-L-19 CB 338 CB-FA-3D Relay Room A/E Relay Room 2

035

-8 Page 2 Appendix R Emergency Lights FHAR3-8.doc Rev. 27 Tag No Building Note 1 Elevation Note 2 Fire Zone or Area Note 3 Location Equipment or Area Being Illuminated Note 4 Number of Lamps FHAR Drawing 1-FHA-EL-L-20 ISPH 308 ISPH-FZ-1 1R 480V Swgr Room North Wall 1R 480V Swgr.

2 046 EL-L-21 CB 355 CB-FA-4A Shift Manager's Office Battery Box only 0

036 EL-L-21A CB 355 CB-FA-4A Main Hallway A/E Hallway 2

036 EL-L-22 CB 355 CB-FA-4A Shift Manager's Office A/E Shift Manager's Office 2

036 EL-L-23 CB 355 CB-FA-4A Conference Room Outside Control Room A/E Conference Room Outside Control Room 2

036 EL-L-24 CB 306 CB-FA-1 Operations Support Center A/E Operations Support Center 2

034 EL-L-25 CB 322 CB-FA-2C Door to Patio North of Old Alt.

Tech Support Center A/E to Remote Shutdown Panel A/B Room 2

035 EL-L-25A CB 338 CB-FA-3B Green Switchgear Room 1E 4160 Swgr. (All Units) 1 035 EL-L-26 CB 322 CB-FA-2C Door South of Old Alt. Tech Support Center A/E to Remote Shutdown Panel A/B Area 2

035 EL-L-35 ISPH 308 ISPH-FZ-2 1T 480V Swgr Room South Wall 1T 480V Swgr.

2 046 EL-L-36 IB 295 IB-FZ-1 Door South of Center Stairway (North side of door)

A/E Stairway and Door 2

039 EL-L-36A IB 295 IB-FZ-1 Door South of Center Stairway (South side of door)

A/E Toward South Entrance of EF-P-1 Room 1

039 EL-L-68 CB 322 CB-FA-2C Door from Stairway to Remote Shutdown Panel A/B Room

1) RSD XFR SW for 1C ESV MCC
2) A/E Hall to Remote Shutdown Panels 2

035 EL-L-69 CB 322 CB-FA-2C Old Alt. Tech Support Center A/E Remote Shutdown Area 2

035 EL-L-72 TB 322 TB-FA-1 6900V Switchgear Room Battery Box only 0

005 EL-L-72A TB 322 TB-FA-1 6900V Switchgear Above Door T202 1A 6900V Swgr.

1 005 EL-L-72B TB 322 TB-FA-1 6900V Switchgear Above Door T202 1B 6900V Swgr.

1 005 EL-L-72C TB 322 TB-FA-1 1C 480V Swgr.

1C 480V Swgr. Unit 2B for VA-P-1A and Unit 2C for VA-P-1C 1

005 EL-L-72D TB 322 TB-FA-1 1J 480V Swgr.

1J 480V Swgr. Unit 2B for VA-P-1B 1

005

-8 Page 3 Appendix R Emergency Lights FHAR3-8.doc Rev. 27 Tag No Building Note 1 Elevation Note 2 Fire Zone or Area Note 3 Location Equipment or Area Being Illuminated Note 4 Number of Lamps FHAR Drawing 1-FHA-EL-L-74 CB 338 CB-FA-3C RSTSP " A " Area RSTSP "A" 2

035 EL-L-74A CB 338 CB-FA-3C RSTSP " A " Area A/E ESAS Relay Cabinets 1

035 EL-L-75 FHB 305 FH-FZ-2 Near Hot Tool Room

1) A/E East toward Hallway to Hot Tool Room
2) A/E West toward Auxiliary Bldg.

2 027 EL-L-75A CB 306 FH-FZ-2 Near Hot Tool Room A/E North toward Hot Tool Room 1

034 EL-L-76 CB 322 CB-FA-2A Near 1A ES MCC 1A ES MCC 1

035 EL-L-76A CB 322 CB-FA-2A Near 1A ES MCC 1A ES MCC 1

035 EL-L-76B CB 322 CB-FA-2A Near 1P 480V Swgr.

1P 480V Swgr 1

035 EL-L-78 CB 322 CB-FA-2B Near 1B ES MCC RSTSP "B" 1

035 EL-L-78A CB 322 CB-FA-2B Near 1S 480V Swgr.

1) 1S 480V Swgr.
2) 1B ES MCC 2

035 EL-L-79 CB 322 CB-FA-2C Near RSTSP "C" Battery Box only 0

035 EL-L-79A CB 322 CB-FA-2C Near 1M ES DC Pnl.

1M ES DC Pnl.

1 035 EL-L-79B CB 322 CB-FA-2C Near RSP B

1) RSP-B
2) Aux RSP B 1

035 EL-L-79C CB 322 CB-FA-2C Near RSP A RSP-A 1

035 EL-L-79D CB 322 CB-FA-2C Near RSTSP C RSTSP "C" 1

035 EL-L-80 CB 322 CB-FA-2D Near 1A/1C/1E Inverter Room West Door Battery Box only 0

035 EL-L-80A CB 322 CB-FA-2D 1A/1C/1E Inverter Room West Wall

1) A/E 1A Inverter Room
2) 1A DC PNL and 1E ES DC PNL 2

035 EL-L-80B CB 322 CB-FA-2E 1B/1D/1F Inverter Room East Wall 1B DC PNL 1

035 EL-L-82 TB 322 TB-FA-1 Near Press. Htr. Disc. Cabinets

1) Press. Htr. Disc. Cabinets
2) RB H&V MCC 1A
3) RB H&V MCC 1B 3

041

-8 Page 4 Appendix R Emergency Lights FHAR3-8.doc Rev. 27 Tag No Building Note 1 Elevation Note 2 Fire Zone or Area Note 3 Location Equipment or Area Being Illuminated Note 4 Number of Lamps FHAR Drawing 1-FHA-EL-L-83 IB 295 IB-FZ-3 Near EF-V-30B/C

1) EF-V-30B
2) EF-V-30C 2

039 EL-L-84 IB 295 IB-FZ-4 Hallway - South Wall Battery Box only 0

039 EL-L-84A IB 295 IB-FZ-2 EF-P-1 Room

1) MS-V-2A, 4A, 10A
2) MS-V-2B, 4B, 10B 2

039 EL-L-84B IB 295 IB-FZ-2 EF-P-1 Room MS-V-2B, 4B 1

039 EL-L-85 DGB 305 DG-FA-2 DGB B Room East Wall

1) A/E North toward D.G. Room Entrances
2) A/E South toward Service Building Entrance 2

044 EL-L-86 FHB 281 FH-FZ-1 Near 1C ESV MCC Battery Box only 0

026 EL-L-86A FHB 281 FH-FZ-1 Near 1C ESV MCC

1) 1C ESV MCC 7D
2) A/E South toward MU-F-2A/B room 2

026 EL-L-86B FHB 281 FH-FZ-1 Near 1C ESV MCC

1) 1C ESV MCC Unit 8D
2) 1C ESV MCC Unit 10C 2

026 EL-L-87 FHB 281 FH-FZ-5 Near Elevator

1) A/E East toward FH Bldg.
2) A/E West toward Make-Up Pump Hallway 2

026 EL-L-88 AB 281 AB-FZ-5 MU-V-11A/B Cubicle Entrance

1) A/E MU-V-11 Valve Cubicle Entrance
2) A/E South away from Make-Up Pump Cubicles 2

026 EL-L-88A AB 281 AB-FZ-5 MU-V-11A/B Cubicle

1) MU-V-11A
2) MU-V-11B, 110 2

026 EL-L-89 AB 281 AB-FZ-4 MU Valve Alley Entrance A/E Stairway Near MU Valve Alley Entrance 1

026 EL-L-89A AB 281 AB-FZ-3 MU Valve Alley MU-V-4, 5, 17, and 98 2

026 EL-L-89B AB 281 AB-FZ-3 MU Valve Alley MU-V-36, 37, 76A, 76B, 89A, and 90 1

026 EL-L-90 AB 281 AB-FZ-4 Near MU-V-14A

1) MU-V-14A
2) DH-V-5B
3) MU Valve Alley 3

026 EL-L-91 AB 281 AB-FZ-4 Near DH-V-12 on South Wall IC-V-3 Handwheel 1

026 EL-L-91A AB 281 AB-FZ-4 Near DH-V-5A on South Wall

1) DH-V-5A
2) IC-V-3 2

026

-8 Page 5 Appendix R Emergency Lights FHAR3-8.doc Rev. 27 Tag No Building Note 1 Elevation Note 2 Fire Zone or Area Note 3 Location Equipment or Area Being Illuminated Note 4 Number of Lamps FHAR Drawing 1-FHA-EL-L-92 AB 281 AB-FZ-5 Bleed Tank Room - East Wall A/E to RC Bleed Tank room 2

026 EL-L-92C AB 281 AB-FZ-5 Hall Between Main Corridor and Bleed Tank Room

1) A/E East toward Main Corridor
2) A/E West toward Waste Tanks 2

026 EL-L-93 AB 271 AB-FZ-1 Heat Exchanger Vault Southeast Wall

1) NR-V-15A, 15B
2) NR-V-18 2

025 EL-L-94 AB 305 AB-FZ-6 Outside MU-V-6A/B Cubicle

1) MU-V-6A, 6B, 8, 70A
2) A/E South Hallway 2

027 EL-L-95 AB 305 AB-FZ-6 Near 1A ESV VCC 1A ESV MCC 2

027 EL-L-96 AB 305 AB-FZ-6A Near 1A Radwaste MCC 1A RW MCC 2

027 EL-L-96A AB 305 AB-FZ-6A Near 1B ESV VCC 1B ESV MCC 2

027 EL-L-97 AB 305 AB-FZ-9 Near 1B Radwaste MCC Battery Box Only 0

027 EL-L-97A AB 305 AB-FZ-9 Near 1B Radwaste MCC A/E South toward Primary AO Station 1

027 EL-L-97B AB 305 AB-FZ-9 Near 1B Radwaste MCC

1) 1B RW MCC
2) 1B RW MCC 2

027 EL-L-97C AB 305 AB-FZ-9 Near 1B Radwaste MCC A/E North toward Rx. Bldg.

1 027 EL-L-98 FHB 281 FH-FZ-1 Laundry Waste Storage Tank Room

1) A/E South toward Entrance
2) A/E North toward 1C ESV MCC 2

026 EL-L-99 AB 281 AB-FZ-5 Main Corridor

1) A/E North toward North Corridor
2) A/E South toward "B" WECST 2

026 EL-L-100 AB 281 AB-FZ-5 Entrance to Hallway leading to Heat Exchanger Vault

1) A/E East toward Rx. Bldg.
2) A/E West toward Heat Exchanger Vault Entrance 2

026 EL-L-101 AB 271 AB-FZ-1 Stairway Down to Heat Exchanger Vault

1) A/E Heat Exchanger Vault Stairway
2) A/E to Southwest area of Heat Exchanger Vault 2

025 EL-L-102 TB 305 TB-FA-1 Near Rx. Bldg. Personnel Access Hatch

1) A/E Rx. Bldg. Personnel Access Hatch
2) A/E to South though Hallway Next to Hot Tool Room 2

040 EL-L-102A TB 305 TB-FA-1 Near Rx. Bldg. Personnel Access Hatch A/E East toward Rx. Bldg. Personnel Access Hatch 1

040

-8 Page 6 Appendix R Emergency Lights FHAR3-8.doc Rev. 27 Tag No Building Note 1 Elevation Note 2 Fire Zone or Area Note 3 Location Equipment or Area Being Illuminated Note 4 Number of Lamps FHAR Drawing 1-FHA-EL-L-103 TB 305 TB-FA-1 Southwest Quadrant

1) A/E North toward Service Bldg.
2) A/E South toward Control Bldg.
3) A/E to Rx. Bldg. Hatch 3

002 EL-L-104 TB 305 TB-FA-1 Northwest Quadrant

1) A/E to Turb. Bldg. Stairway
2) A/E to Int. Bldg. Entrance
3) A/E South toward Service Bldg.

3 003 EL-L-105 SB 305 N/A Corridor to DGB Battery Box only 0

N/A EL-L-105A SB 305 N/A South Wall of Machine Shop by Door TB-150 A/E East toward Machine Shop 1

N/A EL-L-105B SB 305 N/A Southeast Corner of Machine Shop A/E West toward D.G. Bldg.

1 N/A EL-L-105C SB 305 N/A Machine Shop Hallway to DGB A/E West toward D.G. Bldg.

1 N/A EL-L-105D SB 305 N/A Hallway to DGB by Door SB-157 A/E West toward D.G. Bldg.

1 N/A EL-L-106 AB 305 AB-FZ-6 Near Elevator

1) A/E East toward Spent Fuel Cooler Hallway
2) A/E West toward MCC Hallway 2

027 EL-L-107 AB 305 AB-FZ-9 Near Primary Auxiliary Operator Office Portable Emergency Lighting Enclosure #1, near Primary A.O. Room N/A 027 EL-L-108 CB 322 CB-FA-2C Outside Old Alt. Tech Support Center Portable Emergency Lighting Enclosure #2, North of Old Alt. Tech Support Center N/A 035 EL-L-109 IB 305 TB-FA-1 RB Personnel Hatch Portable Emergency Lighting Enclosure #3, Reactor Building Personnel Access Hatch N/A 040 EL-L-226 SB 305 N/A Machine Shop West Wall

1) A/E North Access
2) A/E South Access 2

N/A EL-L-226A SB 305 N/A Machine Shop Northwest Wall

1) A/E North Access
2) A/E South Access 2

N/A EL-L-226B SB 305 N/A Machine Shop Rollup Door to Outside A/E Roll Up Door to Outside 1

N/A EL-L-271 SB 305 N/A South Wall Machine Shop East of Rollup Door Portable Emergency Lighting Enclosure #4, South Wall Machine Shop N/A N/A EL-L-292 FHB 305 FH-FZ-2 RB Wall Facing MU-V-20

1) MU-V-20, 26
2) A/E to MU Valves
3) MU-V-16C, 16D 3

027 EL-L-293 AB 281 AB-FZ-4 RB Wall Near MU-V-3

1) MU-V-3, 16A
2) MU-V-16B, 18 2

026

-8 Page 7 Appendix R Emergency Lights FHAR3-8.doc Rev. 27 Tag No Building Note 1 Elevation Note 2 Fire Zone or Area Note 3 Location Equipment or Area Being Illuminated Note 4 Number of Lamps FHAR Drawing 1-FHA-EL-L-305 TB 322 TB-FA-1 Near South Door of TB Swgr.

Room A/E TB Swgr. Room South Door 2

005 EL-L-306 TB 322 TB-FA-1 Southwest Quadrant Battery Box only 0

005 EL-L-306A TB 322 TB-FA-1 Southwest Quadrant A/E West Toward Stairs by Elevator 1

005 EL-L-306B TB 322 TB-FA-1 Southwest Quadrant A/E South Toward Switchgear Room 1

005 EL-L-307 AB 305 AB-FZ-7 Near DC-P-1A

1) IC-V-4
2) A/E to IC-V-4 2

027 EL-L-311 FHB 281 FH-FZ-1 Near MU-C-2A/B Seal Return Coolers

1) MU-V-189
2) A/E Hallway toward Stairs by Elevator 2

026 EL-L-312 CB 338 CB-FA-3A Red Switchgear Room 1D (Red) 4160V Swgr. Unit 9 for BS-P-1A 3

035 EL-L-322 CB 355 CB-FA-4B Main Control Room (Front Row Left)

Main Control Room Panels and Consoles NA 036 EL-L-323 CB 355 CB-FA-4B Main Control Room (Front Row Center)

Main Control Room Panels and Consoles NA 036 EL-L-324 CB 355 CB-FA-4B Main Control Room (Front Row Right)

Main Control Room Panels and Consoles NA 036 EL-L-325 CB 355 CB-FA-4B Main Control Room (Back Row Left)

Main Control Room Panels and Consoles NA 036 EL-L-326 CB 355 CB-FA-4B Main Control Room (Back Row Center)

Main Control Room Panels and Consoles NA 036 EL-L-327 CB 355 CB-FA-4B Main Control Room (Back Row Right)

Main Control Room Panels and Consoles NA 036 EL-L-328 TB 322 TB-FA-1 West of Condenser, North TBV area CO-V-8, CO-V-108 1

002 EL-L-328A TB 292 TB-FA-1 West of Condenser, north of VA-P-1A CO-V-8, CO-V-108 1

002 Notes:

1. AB=Auxiliary Building, CB=Control Building, DGB=Emergency Diesel Generator Building, FHB=Fuel Handling Building, IB=Intermediate Building, ISPH=Intake Screen and Pump House RB=Reactor Building, SB=Service Building, TB=Turbine Building
2. Elevations are the approximate floor elevation in feet. The elevations shown are not the actual elevation of the light.
3. The designation "N/A" stands for "not applicable"
4. The designation "A/E" stands for "Access and/or Egress".