TMI-1 UFSAR CHAPTER 07 7-i REV. 21, APRIL 2012 CHAPTER 7 - INSTRUMENTATION AND CONTROL TABLE OF CONTENTS SECTION TITLE 7.0 INSTRUMENTATION AND CONTROL 7.1 PROTECTION SYSTEMS 7.1.1 DESIGN BASIS 7.1.1.1 SINGLE FAILURE 7.1.1.2 REDUNDANCY 7.1.1.3 INDEPENDENCE 7.1.1.4 SEPARATION 7.1.1.5 MANUAL TRIP 7.1.1.6 TESTING 7.1.1.7 ENVIRONMENT 7.1.1.8 SEISMIC 7.1.2 REACTOR PROTECTION SYSTEM 7.1.2.1 DESIGN BASIS 7.1.2.2 SYSTEM DESIGN 7.1.2.3 SYSTEM EVALUATION 7.1.3 ENGINEERED SAFEGUARDS ACTUATION SYSTEM 7.1.3.1 DESIGN BASIS 7.1.3.2 SYSTEM DESIGN 7.1.3.3 SYSTEM EVALUATION 7.1.4 EMERGENCY FEEDWATER SYSTEM 7.1.4.1 DESIGN BASIS 7.1.4.2 SYSTEM DESIGN 7.1.4.3 SYSTEM EVALUATION 7.1.5 DIVERSE SCRAM SYSTEM 7.1.5.1 DESIGN BASIS OF ATWS 7.1.5.2 DSS DESIGN 7.1.5.3 TTFWPT DESIGN 7.1.5.4 SYSTEM EVALUATION 7.2 REGULATION SYSTEMS 7.2.1 DESIGN BASES 7.2.2 CONTROL ROD DRIVE SYSTEM 7.2.2.1 DESIGN BASIS 7.2.2.2 SYSTEM DESIGN 7.2.2.3 SYSTEM EVALUATION 7.2.3 INTEGRATED CONTROL SYSTEM 7.2.3.1 DESIGN BASIS 7.2.3.2 SYSTEM DESIGN 7.2.3.3 SYSTEM EVALUATION 7.2.3.4 DELETED

TMI-1 UFSAR TABLE OF CONTENTS (cont'd)

SECTION TITLE CHAPTER 07 7-ii REV. 21, APRIL 2012 7.3 INSTRUMENTATION 7.3.1 NUCLEAR INSTRUMENTATION 7.3.1.1 DESIGN BASIS 7.3.1.2 SYSTEM DESIGN 7.3.1.3 SYSTEM EVALUATION 7.3.2 NON-NUCLEAR INSTRUMENTATION 7.3.2.1 DESIGN BASIS 7.3.2.2 SYSTEM DESIGN 7.3.2.3 SYSTEM EVALUATION 7.3.3 INCORE MONITORING SYSTEM 7.3.3.1 DESIGN BASIS 7.3.3.2 SYSTEM DESIGN 7.3.3.3 SYSTEM EVALUATION 7.3.4 SAFETY PARAMETER DISPLAY SYSTEM 7.3.4.1 DESIGN BASIS 7.3.4.2 ELECTRICAL ISOLATION 7.3.4.3 HUMAN FACTORS PROGRAM 7.4 OPERATING CONTROL STATIONS 7.4.1 GENERAL LAYOUT 7.4.1.1 SAFETY FEATURES 7.4.2 INFORMATION DISPLAY AND CONTROL FUNCTION 7.4.2.1 CONSOLE AND PANEL LAYOUT 7.4.2.2 MAN-MACHINE RELATIONSHIP 7.4.3

SUMMARY

OF ALARMS 7.4.4 COMMUNICATION 7.4.5 HABITABILITY 7.4.5.1 PROTECTION AGAINST FIRE 7.4.5.2 PROTECTION AGAINST RADIOLOGICAL RELEASES 7.4.5.3 TOXIC GAS PROTECTION 7.4.5.4 TESTING AND INSPECTION 7.4.6 REMOTE SHUTDOWN SYSTEM 7.4.7 EMERGENCY FACILITIES AND EQUIPMENT

7.5 REFERENCES

TMI-1 UFSAR CHAPTER 07 7-iii REV. 21, APRIL 2012 CHAPTER 7 - INSTRUMENTATION AND CONTROL LIST OF TABLES TABLE TITLE 7.1-1 REACTOR TRIP

SUMMARY

7.1-2 ENGINEERED SAFEGUARDS ACTUATED DEVICES 7.1-3 ENGINEERED SAFEGUARDS ACTUATION SYSTEM SETPOINTS 7.2-1 INTEGRATED CONTROL SYSTEM TRANSIENT LIMITS 7.3-1 SAFETY GRADE PLANT VARIABLES (INDEPENDENT OF ICS/NNI DISPLAYS) 7.3-2 EVALUATION OF TMI-1 COMPLIANCE WITH REGULATORY GUIDE 1.97 REQUIREMENTS 7.3-3 TMI-1 SAFETY PARAMETER DISPLAY SYSTEM PARAMETERS 7.4-1 REMOTE SHUTDOWN SYSTEM CONTROL AND MONITORING FACILITIES

TMI-1 UFSAR CHAPTER 07 7-iv REV. 21, APRIL 2012 CHAPTER 7 - INSTRUMENTATION AND CONTROL LIST OF FIGURES FIGURE TITLE 7.1-1 DELETED 7.1-2 CORE PROTECTION SAFETY LIMITS 7.1-3 PRESSURE TEMPERATURE BOUNDARIES 7.1-4 SAFEGUARDS ACTUATION SYSTEM 7.1-5 LOGIC DIAGRAM FOR MS-V-13A AND EF-P2A ACTUATION 7.1-6 LOGIC DIAGRAM FOR MS-V-13B AND EF-P2B ACTUATION 7.1-7 EFW CONTROLS (TYPICAL FOR EACH EF CONTROL VALVE) 7.1-8 DELETED 7.1-9 DELETED 7.2-1 AUTOMATIC CONTROL ROD GROUPS - TYPICAL WORTH CURVE VS DISTANCE WITHDRAWN 7.2-2 DIGITAL CONTROL ROD DRIVE CONTROL SYSTEM AND REACTOR TRIP BREAKER CONFIGUATION 7.2-3 DELETED 7.2-4 DELETED 7.2-5 DELETED 7.2-6 DELETED 7.2-7 DELETED 7.2-8 REACTOR AND STEAM TEMPERATURES VS REACTOR POWER 7.2-9 DELETED 7.3-1 NUCLEAR INSTRUMENTATION SYSTEM 7.3-2 NUCLEAR INSTRUMENTATION FLUX RANGES

TMI-1 UFSAR LIST OF FIGURES (cont'd)

FIGURE TITLE CHAPTER 07 7-v REV. 21, APRIL 2012 7.3-3 NUCLEAR INSTRUMENTATION DETECTOR LOCATIONS 7.3-4.1.1 DELETED 7.3-5 DELETED 7.3-6 INCORE DETECTOR LOCATIONS 7.3-7 INCORE MONITORING CHANNEL 7.4-1 DELETED 7.4-2 CONTROL BUILDING LAYOUT 7.4-3 CONTROL BUILDING HVAC SYSTEM - EMERGENCY MODE