Public Service Electric and Gas Company Stanley LaBruna Public Service Electric and Gas Company P.O. Box 236, Hancocks Bridge, NJ 08038 609-339-1200 Vice President - Nuclear Operations APR 2 4 1991 NLR-N91067 United States Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 1990 ANNUAL RADIOLOGICAL ENVIRONMENTAL OPERATING REPORT SALEM AND HOPE CREEK GENERATING STATIONS DOCKET NOS. 50-272, 50-311 AND 50-354 As required by Section 6.9.1.10 of Appendix A to Facility Operating Licenses DPR-70 and DPR-75 for Salem Generating Station, Units No. 1 and 2, and Section 6.9.1.6 of Appendix A to Facility Operating License NPF-57 for Hope Creek Generating Station, Public-service Electric and Gas hereby transmits one copy of the 1990 Annual Radiological Environmental Operating Report.

This report summarizes the results of the radiological environmental surveillance program for 1990 in the vicinity of the Salem and Hope Creek Generating Stations.

The result of this program for 1990 were specifically compared to the result of the preoperational program.

Should you have any questions or comments regarding this submittal, please do not hesitate to contact us.

Enclosure

~-- --9:to5c>~'.t122:::: *~012::::r-----\\

PDR ADOCK 05000272 R

PDR Sincerely,

,~

AP y,\\1

L Document Control Desk NLR-N91067 c

Mr. J. c. Stone 2

Licensing Project Manager -

Salem Mr. Stephen Dembek Licensing Project Manager -

Hope Creek Mr. T. Johnson Senior Resident Inspector Mr. T. Martin, Administrator Region I Mr. Kent Tosch, Chief New Jersey Department of Environmental Protection Division of Environmental Quality Bureau of Nuclear Engineering CN 415 Trenton, NJ 08625 APR 2 4 1991

~---.

~

!~

I RTL-ENV-91-01 ARTIFICIAL ISLAND RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM For Salem Generating Station, Unit 1: Docket No. 50-272 Salem Generating Station, Unit 2: Docket No. 50-311 Hope Creek Generating Station: Docket No. 50-354 1990 ANNUAL RADIOLOGICAL ENVIRONMENTAL OPERATING REPORT JANUARY 1 TO DECEMBER 31, 1990 Prepared By PUBLIC SERVICE ELECTRIC AND GAS COMPANY RESEARCH AND TESTING LABORATORY APRIL 1991

ARTIFICIAL ISLAND RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM GENERATING STATIONS 1990 ANNUAL RADIOLOGICAL ENVIRONMENTAL OPERATING REPORT JANUARY 1 TO DECEMBER 31, 1990

TABLE OF CONTENTS PAGE S~Y.

1 INTRODUCTION...... *.. * *... *. *. * *........ *......... *.........

3 Radiation Characteristics...............................

3 Radiation Effects.......................................

4 Sources of Radiation Exposure...........................

4 Nuclear Power Reactors..................................

7 Containment of Radioactivity ***......**....*.....*......

13 Sources of Radioactive Liquid and Gaseous Effluents.....

16 Radioactivity Removal from Liquid and Gaseous Wastes..*.

16 THE RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM **..**.*...

18 Objectives...............................................

19 Data Interpretation.....................................

2 o Quality Assurance Program..***.....*.*.........*. ~......

21 Results and Discussion *....**.*.*....*...*..*.....*.....

21 Atmospheric.........................................

22 Direct Radiation... ~................................

25 Terrestrial.........................................

25 Aquatic.............................................

32 Program Deviati_ons................................. -:-....

3 9 Conclusions.............................................

4 o REFERENCES * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *. * * * * * * * * * * * * * * * *

  • 5 5 APPENDIX A -

PROGRAM

SUMMARY

57 APPENDIX B -

SAMPLE DESIGNATION AND LOCATIONS *.***.*****..*.

71 APPENDIX C -

DATA TABLES ***.*******.******.*.*******.******.

79 APPENDIX D -

SYNOPSIS OF ANALYTICAL PROCEDURES.******.*****. 123 APPENDIX E -

SUMMARY

OF USEPA ENVIRONMENTAL RADIOACTIVITY LABORATORY INTERCOMPARISON STUDIES PROGRAM RESULTS. *. * *. *. * *. * * * * *.. * *. *... *.............. 16 3

~

APPENDIX F -

SYNOPSIS OF LAND USE CENSUS ****.***.*...***..** 171 i

TABLE NUMBER

1.
2.

FIGURE LIST OF TABLES TABLE DESCRIPTION Common Sources of Radiation **........*.*......*.*..

1990 Artificial Island Radiological Environmental Monitoring Program (Program Overview) *.*.***...*..*

LIST OF FIGURES PAGE 6

41 NUMBER FIGURE DESCRIPTION PAGE

1.

BWR Vessel and Core*............................. *..

9

2.

Schematic of BWR Power Plant *.****...*...**.....**.

3.

Schematic of PWR Power Plant *..***...*.*.......**..

12

4.

Primary PWR Containment Cross-Section (Salem Units 1 & 2)........... *............. ID.......

14

5.

BWR Mark 1 Primary Containment Cross-Section (Hope Creek)....................*. *........ o 15

6.

Beta in Precipitation and Air Particulate 1973 through 1990 (Quarterly)....*.........*.......

45 GA.

Beta in Precipitation and Air Particulate 1986 through 1990 (Monthly) ***.........*......*.*..

46 ii

LIST OF FIGURES (cont'd.)

FIGURE NUMBER FIGURE DESCRIPTION PAGE

7.

Ambient Radiation - Offsite Vs Control Station 1973 through 1990 (Quarterly)......................

47 7A.

Ambient Radiation - Offsite Vs Control Station 1986 through 1990 (Monthly)........................

48

8.

Iodine-131 Activity in Milk 1973 through 1990 (Quarterly)......................

49 8A.

Iodine-131 Activity in Milk 1986 through 1990 (Monthly).......... *.............

50 _.,,

9.

Gross Beta and Potassium-40 Activity in Surface Water 1973 through 1990 (Quarterly)......................

51 9A.

Gross Beta and Potassium-40 Activity in Surface Water 1986 through 1990 (Monthly)........................

52

10.

Tritium Activity in Surface Water 1973 through 1990 (Quarterly)......................

53 lOA.

Tritium1Activity in Surface Water 1986 through 1990 (Quarterly)......................

54 iii

SUMMARY

During normal operations of a nuclear power generating station

  • there are releases of small amounts of radioactive material to the environment.

To monitor and determine the effects of these releases a radiological environmental monitoring program (REMP) has been established for the environment around Artificial Island where the Salem Units 1 and 2 (SGS) and Hope Creek (HCGS)

Generating stations are located.

The results of the REMP are published annually, providing a summary and interpretation of*

the data collected.

Additional data relating to the releases of radioactive materials to the environment can be obtained in the Radiological Effluent Release Report (RERR) which is published and submitted to the Nuclear Regulatory Commission on a semi-annual frequency.

The PSE&G Research and Testing Laboratory (RTL) has been responsible for the collection and analysis of environmental samples during the period of January 1, 1990, through December 31, 1990, and the results are discussed in this report.

The radioactive liquid and gaseous effluents due to the operation of SGS and HCGS during 1990 did not adversely affect the environment around Artificial Island.

Most of the radioactive materials noted in this report are normally present in the environment, either naturally, such as potassium-40, or as a result of non-nuclear generating station activity such as nuclear bomb testing.

Measurements made in the vicinity of Artificial Island were compared to background or control measurements and the preoperational REMP study performed before Salem Unit 1 became operational.

Samples of air particu-lates, air iodine, precipitation, milk, surface, ground and drinking water, vegetables, beef, game, fodder crops, fish, crabs, and sediment were collected and analyzed.

External radiation dose measurements were also made in the vicinity of Artificial Island using thermoluminescent dosimeters.

To demonstrate compliance with Technical Specifications (Section 3/4.12.1), most samples were analyzed for gamma emitting isotopes, tritium (H-3), strontium-89 (Sr-89) and 90 (Sr-90),

iodine-131 (I-131), gross beta and gross alpha.

The results of these analyses were used to assess the environmental impact of SGS and HCGS operations, thereby demonstrating compliance with Technical Specifications (Section 3/4.11) and applicable Federal and State regulations, and to verify the adequacy of radioactive effluent control systems.

The results provided in this report are summarized below:

  • There were a total of 2173 analyses on 1321 environmental samples during 1990.

Direct radiation dose measurements were also made using 448 thermoluminescent dosimeters (TLDs).

1

In addition to the detection of natural-occurring isotopes (i.e. Be-7, K-40, Ra-226 and Th-232), low levels of Mn-54, Co-58, Co-60, Sr-89, Sr-90, and Cs-137 were also detected in various media.

The detection of these radionuclides can be attributed to atmospheric weapons fallout, statistically positive results (within the lower limit of detection (LLD) range of the isotope but with a large margin of error) or coincident sampling at the time a effluent release was in progress.

All of these radionuclides were at concentrations well below Technical Specification reporting levels.

  • Dose measurements made with TLDs at 41 locations around Artificial Island averaged 59 millirads for 1990.

This was comparable to the preoperational phase of the program*

which had an average of 55 millirads for 1973 to 1976.

L _____

2 ______

INTRODUCTION This section gives a brief description of the characteristics, effects, and sources of radiation and the operation of a nuclear generating station, both a boiling water reactor and a pressurized water reactor.

It is hoped that this will provide the reader with a better understanding of this report.

RADIATION CHARACTERISTICS The word "radioactive" describes the state of the nucleus of an atom containing an excess of energy.

The excessive energy is usually due to an imbalance in the number of electrons, protons, and/or neutrons which make up the atom.

To release this excess energy the atom emits electromagnetic or particulate radiation to become stable (non-radioactive).

This process is called radioactive decay.

Part of the electromagnetic spectrum consists of gamma-rays and x-rays, which are similar in nature to light and microwaves.

Particulate radiation may be in the form of electrically charged particles such as alpha (2 protons plus 2 neutrons) and beta (1 electron) particles, or have no charge at all (neutron).

Radioactive decay is measured in terms of "half-life".

The half-life may be defined as the amount of time it takes for a radio-active material to decay to half of its original activity.

The half-life of a radionuclide depends on the radionuclide and can range anywhere from a fraction of a second to as long as several million years.

Each radionuclide also has a unique decay characteristic, both in terms of the energy of its radiation and the types of its radiation.

Radionuclides may decay directly into a stable element or go through a series of decays (becoming several different radioisotopes) before eventually becoming a stable element.

Radioactivity is measured by the number of nuclear disintegra-tions (decays) of the source of radiation per unit of time.

The unit of this measurement is called the curie.

One curie equates to 2.2 trillion disintegrations per minute. For the purpose of quantifying the effluents of a nuclear power reactor this unit is broken down into a microcurie and a picocurie.

The microcurie is one millionth of a curie and represents 2.2 million decays per minute, while the picocurie is one millionth of a microcurie and represents 2.2 decays per minute.

3

~----------------------

RADIATION EFFECTS Radiation effects are measured in terms of the amount of biological damage produced.

Biological damage from electro-magnetic and particulate radiation is produced by ionizing an atom, breaking a chemical bond, or altering the chemistry of living cell.

To assess biological damage, the type, energy, amount of radiation must be considered.

a and There are essentially two types of exposure to radiation:

external and internal.

External exposure can involve the total body, thereby implying exposure to all organs, or parts of the body, such as the arm, foot, or head.

Internal exposure, meaning the uptake of radioactive elements by inhalation, ingestion, or by means of a cut, can involve a single selective organ or several organs.

An example of the selectivity of internal exposure is the uptake of a radioiodine which concentrates in the thyroid gland, versus the uptake of a radiocesium which will collect in the muscle and liver.

The quantity of the radionuclide and duration of time a radionuclide remains in the body directly influences the total exposure or dose to an organ.

The duration of time depends on the amount of radioactive decay and the length of time it takes to remove the radionuclide from the body (biological decay). It should be noted that the biological effect of radiation is independent of the source (internal or external) and dependent on the dose.

The measurement of dose to man is typically expressed in terms of a unit called the rem.

As a better unit of dose, the millirem (mrem; 1 mrem =1/1000 rem) is most often used because the typical dose is usually on the order of thousandths of a rem.

Another term used is the collective dose to a population, called a person-rem.

A person-rem is calculated by adding up each individual dose to a population (e.g. 0.0001 rem to each person of a population of 10,000 persons= 1 person-rem).

SOURCES OF RADIATION EXPOSURE Radioactive elements have existed on our planet (and on every-thing that has emerged from it) since its formation, including our own bodies.

Every second over 7000 atoms undergo radioactive decay in the body of the average adult (or roughly 420,000 disintegrations per minute) from natural background.

4

Many sources of radiation exist today and, of them, the most universal and least controllable is background radiation from terrestrial radioactivity and cosmic rays.

Terrestrial radioactivity originates from such radionuclides as potassium-40 (K-40), uranium-238 (U-238), thorium-232 (Th-232), radium-226 (Ra-226), and radon-222 (Rn-222).

Some of these radionuclides have half-lives of millions of years and are introduced into the water, soil, and air by such means as volcanoes, weathering, erosion, diffusion, and radioactive decay.

One naturally-occurring terrestrial radionuclide is a significant source of radiation exposure to the general public---radon gas.

Radon gas (Rn-222) is an inert gas produced in the ground from the radioactive decay of radium (from the decay of uranium and thorium) and emitted into the air.

Because of the use of lime and gypsum (which would contain radium) in its production, building materials such as cinder block, sheet rock, and concrete are also radon gas sources.

Concentrations of radon gas are dependent on the concentrations of radium (uranium and thorium) in the soil, altitude, soil permeability, temperature, pressure, soil moisture, rainfall, snow cover, atmospheric conditions, and season.

The gas can move through cracks and openings into base-ments of buildings, become trapped in a small air volume indoors and result in higher concentrations than found outdoors.

Radon can also be dissolved in well water and contribute to airborne radon in houses when released through showers or washing.

Since radon gas is radioactive, it, too, continues to produce, by decay, other radioactive materials referred to as radon daughters.

These daughters are solid particles which can stick to surfaces such as dust particles in the air.

The dust containing the radon daughter particles can be inhaled and deposited in the lungs.

Radon daughters emit high energy alpha particles which results in an average dose to the lungs of 300 mrem (0.3 rem to a 10 year old) in the United States.

In areas such as New Jersey and Pennsylvania, over a geological formation known as the Reading Prong, doses much higher than 300 rem/yr have been recorded due to natural deposits of uranium.

Doses due to radon gas and its daughters are the highest dose contributor to individuals from all natural sources.

Cosmic rays are high energy electromagnetic rays which originate from outer space.

About 300 cosmic rays pass through each person every second.

Cosmic rays also interact with atoms in the earth's atmosphere and produce radioactive substances such as carbon-14 (C-14), sodium-22 (Na-22), beryllium-7 (Be-7), and tritium (H-3).

Some of these radionuclides become deposited on land and water while the rest remain suspended in the atmosphere.

Other naturally-occurring sources of radiation which contribute to doses to the human body are trace amounts of uranium and radium in drinking water and radioactive potassium in milk.

Sources of naturally-occurring radiation and their average dose contribution are summarized in Table 1.

5

TABLE 1 COMMON SOURCES OF RADIATION*

Natural sources Approximate Dose Cmrem/yearl Manmade Sources Approximate Dose (mrem/year)

Cosmic Rays Building Materials Internal Ground APPROXIMATE TOTAL 42 35 28 11 100 Medical radiation Television and consumer products Weapons Fallout Nuclear Power Plants

Reference:

NUREG-0558 and EPA Report ORP/SID 72-1 90 1-5 2-5 1

100 The average individual in the United States receives approxi-mately 100 mrem per year from natural sources.

In some areas the dose from natural radiation is significantly higher.

Residents of Colorado receive an additional 80 mrem per year due to the increase in cosmic (higher elevation) and terrestrial radiation levels.

Transcontinental and intercontinental airline pilots receive 1000 mrem/yr due to the high elevation and length of these flights and resultant higher cosmic radiation levels.

In several locations around the world high concentrations of mineral deposits give natural background radiation levels of several thousand mrem per year.

The average individual is also exposed to radiation from a number of man-made sources.

The single largest of these sources comes from medical diagnostic tools such as X-rays, CAT-scans, fluoroscopic examinations and radio-pharmaceuticals.

Approximately 160 million people in the United States are exposed to medical or dental X-rays in any given year.

The annual dose to an individual from such medical irradiation averages 90 mrem which is approximately equal to the annual sum of natural radiation.

Smaller doses from man-made sources come from consumer products (television, smoke detectors, fertilizer), fallout from prior nuclear weapons tests, and production of nuclear power and its associated fuel cycle.

There are approximately 200 radionuclides produced in the nuclear weapons detonation process; a number of these are detected in fallout.

Fallout commonly refers to the radioactive debris that s~ttles to the surface of the earth following the detonation of nuclear weapons.

Fallout can be washed down to the earth's surface by rain or snow and is dispersed throughout the environ-ment.

The radionuclides found in fallout which produce most of the fallout radiation exposures to man are I-131, Sr-89, Sr-90, and cs-137.

There have been no atmospheric weapons tests in this country since 1964.

~--------6---------~-

NUCLEAR POWER REACTORS After World War II and during the development of atomic weapons, an understanding of the great energy potential from atomic chain reactions was realized and put to peaceful use.

Among the most successfully developed peaceful uses were nuclear power reactors.

It was known that the fission reactions in an atomic weapon detonation generated large amounts of energy and heat.

If that energy and heat could be harnessed, electricity could be produced.

As a comparison, one pound of uranium-235 (the fuel of a nuclear reactor) could produce the heat of 1,500 tons of coal.

So, at the University of Chicago, under the direction of Enrico Fermi, the world's first nuclear reactor began operation (went critical) on December 2, 1942.

It wasn't until 1957 that the nuclear reactor was first used to commercially produce electricity in Shippingport, Pennsylvania.

Today there are over 100 reactors for public power generation of electricity in this country and 300 in the world.

The function of a nuclear reactor is to generate heat to produce electricity.

The generation of heat is accomplished by permitting self-sustaining, controlled nuclear fissions.

Nuclear fission is the splitting of an atom when hit by a neutron, which, in turn, produces two entirely different atoms, as well as generating a lot of heat.

When one fission occurs more neutrons are given off which leads to more atoms to fission, producing more neutrons etc., thus giving rise to a chain.reaction.

The atom bomb, using large masses of fissionable material, is a chain reaction uncontrolled.

Nuclear reactors, on the other hand, use small masses of fissionable material (thus making it impossible for a nuclear explosion), and are therefore able to sustain a controlled chain reaction.

The best known and most widely used material for the fission reaction is uranium-235.

Most uranium exists in the form U-238 (238 refers to the atomic mass, i.e., the number of protons and neutrons combined).

However, it also exists in the form of uranium-235 which is in a proportion of one atom per 140 atoms of U-238.

Uranium-235 becomes very unstable when its nucleus is struck by a neutron.

To overcome the instability, the uranium atoms split (fission) and become two fission products (e.g.

Iodine 131 and Xenon 133).

When the fission occurs, some neutrons are released to initiate another fission and start a chain reaction.

There are several different ways to control the rate of a chain reaction.

Some of these means are the use of moderators, varying the.size of a reactor vessel, and using neutron absorbing materials (such as cadmium) as control rods.

7

There are three major types of nuclear reactors in operation in the world:

the pressurized light-water reactor (PWR), boiling light-water reactor (BWR), and the gas-cooled reactor.

The nuclear reactors built and operating on Artificial Island are the BWR (Hope Creek) and.the PWR (Salem Units 1 and 2).

Of the two types of light-water reactors (LWR), the BWR has a simpler design.

In a BWR the steam desired to generate electricity is produced in the core itself.

Here, step by step, is how the BWR works (refer to Figures 1 and 2):

1.

Water enters the reactor vessel through the reactor core which consists of 764 fuel assemblies.

Each assembly consists of 64 zirconium alloy fuel rods about 13 feet long. Sixty-two of these rods contain uranium fuel pellets.

The fuel pellets have been enriched so that the U-235-to-U-238 ratio is now one atom of U-235 to every 20 to 40 atoms of U-238.

The core is contained in a 6 11 thick steam reactor vessel about 75 feet high and weighing 624 tons.

2.

The water flows along the fuel rods.

Then, when the 185 control rods (containing cadmium) are withdrawn, the fissioning process in the fuel rods generates heat that causes the water passing through the core to boil into steam in the reactor vessel.

3.

The steam flows through the steam lines at the top of the reactor directly into a turbine generator (see Figure 2).

4.

In the turbine, the force of the steam striking the blades attached to a shaft causes the shaft to spin.

5.

The shaft spins inside a generator, causing a magnetic field to move through coils of wire to produce electricity.

6.

A second separate water system, carrying cooling water from an outside source (e.g. the cooling tower located on Artificial Island), condenses the steam back to water.

7.

The condensed water is then pumped back into the reactor vessel to start the entire cycle again.

The fission chain reaction is controlled by the 185 control rods located between the fuel assemblies.

These control rods contain material which absorbs neutrons and controls the rate of fissioning.

By moving the control rods up or down, tlie reactor can sustain a chain reaction at desired power levels.

By inserting them all the way into the reactor core, fissioning can be completely stopped.

8

FIGURE 1 FEEDWATER (FROM CONDENSER)

RECIRCUl_ATION PUMP JET PUMP BWR VESSEL & CORE FEEDWATER L<....L.J..._~ (FROM CONDENSER)

RECIRCULATION PUMP

1-1 0

FIGURE 2 SCHEMATIC OF BWR POWER PLANT DRYWELL (PRIMARY CONTAINMENT) 1

~

SHIELD BUILDING ST EA M --------!>

REACTOR ~--.-r----,-,------~

VESSEL PRESSURE SUPPRESSION POOL (TORUS)

TURBINE 1-WATER GENERATOR COOLING TOWER

~

~~====!J

~*===~

~

COOLING WATER (RIVER)

A PWR differs from a BWR in that water inside the reactor vessel system is pressurized to prevent boiling (steam) when heated.

This pressurized hot water is used to heat a second source of water, at a lower pressure, which will produce steam to turn the turbines.

The following step-by-step outline indicates how the PWR works (see Figure 3):

1.

Within the 424-ton reactor vessel at SGS, water flows across 193 fuel assemblies in the reactor core.

Each assembly consists of 264 fuel rods, each about 15 feet long.

2.

The water flows along the fuel rods.

When the 53 control rods are raised, the fissioning process begins and the water is heated to about 600°F by the nuclear fission process.

This water is referred to as the primary coolant.

The primary coolant is maintained at about 2000 psi of pressure to keep the water from boiling, hence a pressurized water system.

3.

The primary coolant flows from the reactor as a hot liquid to tubes in the steam generators where the water gives up its heat (cooled) to the water in the steam generator.

The water in the steam generator is called secondary coolant.

The primary water, after giving up its heat, is returned to the reactor core to start the process over.

4.

The secondary coolant in the steam generator is not under high pressure and turns to steam because of the primary coolant heat-up.

This steam is sent through steam lines to the turbine generator to generate electricity in the same method as outlined in the BWR description above.

5.

The exhausted steam from the turbine is channeled into the condenser below the turbine, cooled back into water and returned to the steam generators.

The cooling action of the condenser is provided by a third (tertiary coolant) system of circulating water drawn from a river, ocean, or lake (at SGS, this is the Delaware River).

About 65 percent of the nuclear power plants in the United states are PWRs and 35 percent are BWRs.

The PWR is also used in nuclear submarines and other navel vessels.

11

FIGURE 3 STEEL (SHELL) LINER REACTOR

.. *.*.).*.*

  • REACTOR PRIMARY
  • .. COOLANT SYSTEM

.**. REACTOR

. ****COOLANT PUMP STEAM GENER-ATOR SCHEMATlC OF PWR POWER PLANT OUTER CONCRETE (CONTAINMENT SHIELD)

PRIMARY SYSTEM SECONDARY SYSTEM TURBINE CONDENSER WATER (CONDENSATE)

GENERATOR COOLING WATER (RIVER)

CONTAINMENT OF RADIOACTIVITY The radioactivity present in a nuclear reactor is not just derived from U-235 fuel and the fission products generated from the chain reaction.

Other radioactive substances are generated by means of activation.

Activation products are corrosion materials, from component and structural surfaces in the coolant water, that become radioactive.

The materials become radioactive or activated when hit by neutrons from the fission reaction.

There are a series of several barriers to contain the radio-activity present in a light water reactor.

The first of these is the nuclear fuel itself.

The fission products are trapped inside the ceramic fuel pellets that are designed to retain them.

The fission products that are gaseous or volatile migrate out of the fuel.

Encasing the fuel pellets are metal f~el rods (known as fuel cladding) designed to retain the fuel pellets.

The small fraction of fission products that might leave the fuel pellets' (such as the gaseous products) are collected here in small gaps between the fuel pellets and cladding.

The next barrier level is the cooling water which is circulated around the fuel rods.

The fission and activation products (such as radioiodines, strontiums, and cesiums) are soluble and are retained in the coolant.

These materials can be removed by filter and purification systems used for the coolant.

The next level is the reactor vessel.

The reactor vessel is a steel structure (6 to 8 inches thick) which contains the fuel rods and coolant.

The vessel and its coolant systems provide containment for all radionuclides in the coolant.

From here the PWR and BWR differ in structure.

The next barrier around a PWR reactor vessel is the containment building which is a four-foot thick, steel-reinforced (Salem Units 1 and 2 also include a steel liner) concrete structure (see Figure 4).

It is designed to contain water and gases which may accidentally escape the above barriers.

The containment is also designed to with-stand tornadoes, floods, and earthquakes.

In a BWR, the reactor vessel is contained in a drywell and pressure suppression chamber (see Figure 5).

This system is designed to reduce the pressure and water build-up that may occur during a break in the steam piping.

The walls of the drywell (which are two feet thick) consist of concrete with a steel containment shield over the reactor vessel top.

The reactor vessel and drywell system is surrounded by a steel reinforced reactor building structure (see Figure 2).


~13

FIGURE 4 PRIMARY PWR CONTAINMENT CROSS-SECTION (SALEM UNITS 1 & 2) 191' 6" GROUND LEVEL

_f FAN COIL UNIT POLAR GANTRY CRANE 156'6" 14 STEAM GENERATOR ACCUMULATOR FAN COIL UNIT CONCRETE 4'-6' GROUND LEVEL

DRY WELL FIGURE 5 BWR MARK I PRIMARY CONTAINMENT CROSS-SECTION (HOPE CREEK)

-~

REC I RC PUMP PRESSURE SUPPRESSION POOL 15

SOURCES OF RADIOACTIVE LIQUID AND GASEOUS EFFLUENTS Under normal operating conditions for nuclear power plants most of the fission products are retained within the fuel and fuel cladding.

However, small amounts of radioactive fission products are able to diffuse or migrate through the fuel cladding and into the primary coolant.

Trace quantities of the component and structure surfaces, which have been activated, also get into the primary coolant water.

Many of the soluble fission and activation prodqcts, such as radioactive iodines, strontiums, cobalts, and cesiums are removed by demineralizers. in the purification system of the primary coolant.

The noble gas fission products have a very low solubility in the primary coolant and therefore cannot be removed by the demineralizers.

Instead, they are released as a gas when the primary coolant is depressurized and are collected by a system designed for gas collection and decay.

This represents the principal source of gaseous effluents.

Small releases of radioactive liquids from valves, piping, or equipment associated with the primary coolant system may occur in the reactor, auxiliary, and fuel handling buildings.

The noble gases become part of the gaseous wastes, while the remain-ing radioactive liquids are collected in floor and equipment drains and sumps and are processed prior to release.

Processed primary coolant water that does meet chemical specifications for reuse may also become waste water.

These represent the principal sources of liquid effluents.

RADIOACTIVITY REMOVAL FROM LIQUID AND GASEOUS WASTES In a nuclear power plant, radioactive liquid and gaseous wastes are collected, stored, and processed through processing systems to remove or reduce most of the radioactivity (exclusive of tritium) prior to reuse within the plant or discharge to the environment.

These primary systems are required by Technical Specifications to be installed and operable and help to ensure that all releases of radioactive liquid and gaseous effluents are as-low-as-reasonably-achievable (ALARA).

At both SGS and HCGS, liquid waste is routed through demineral-izers and filters which clean the water for recycling.

If the demineralized water does not meet the requirements for reuse, the water is stored in tanks for sampling and then analyzed for radioactivity and chemical content before being discharged to the Delaware River.

If the water does not meet the requirements for release to the environment, then the liquid wastes are processed through the appropriate portions of the liquid waste treatment 16

system to provide assurance that the releases of radioactive liquid effluents will be kept ALARA.

All concentrates produced from the demineralizers are packaged as solid waste for shipment and burial at an offsite burial facility.

At Salem, the circulating water system provides an additional minimum of 185,000 gallons per minute dilution flow for liquid releases.

At Hope Creek, the cooling tower provides an additional 19,000 gallons per minute dilution flow prior to discharge to the Delaware River.

The average flow rate of the Delaware River is five million gallons per minute and provides additional dilution.

In SGS, the waste gases collected by the vent header system are first routed to the gas compressors which compress the gases into waste gas decay tanks.

After a waste gas decay tank is filled, the tank contents may be stored for a period up to 90 days (generally) to allow for decay of the shorter-lived radio-nuclides.

In HCGS, the waste gases from the main condenser air ejectors are collected and delayed from release in the offgas system.

The discharge of all waste gases at HCGS and SGS is made through high efficiency particulate air (HEPA) filters and charcoal filters prior to release.

The filters are rated to be 95% efficient for iodines and greater than 99% efficient for removal of particulates.

Noble gases, however, cannot be removed by these filters.

Gaseous effluents are discharged through elevated vents which enhances atmospheric dispersion and dilution.

Radioactive effluent releases are limited and controlled by release concentrations and dose limits, per Technical Specifica-tions and the U.S. Nuclear Regulatory Commission's regulation in Title 10 of the Code of Federal Regulations, Part 20 (10 CFR 20).

These regulations are based on recommendations of the Inter-national Commission on Radiological Protection (ICRP), the National Council on Radiation Protection and Measurements (NCRP) and the Federal Radiation Council (FRC) for basic radiation protection standards and guidance.

The operations of the Hope Creek and Salem Generating Stations (Units 1 and 2), and their associated effluent releases, were well within the 10 CFR 20 limits and maintained ALARA.

17

THE RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM Artificial Island is the site of Salem and Hope Creek Generating Stations.

The Salem Generating Station (SGS) consists of two operating pressurized water nuclear power reactors.

Salem Unit One has a net rating of 1090 MWe (3338 MWt), and Salem Unit Two is rated at 1115 MWe (3411 MWt).

The Hope Creek Generating station (HCGS) is a boiling water nuclear power reactor which has a net rating of 1067 MWe (3293 MWt).

Artificial Island is a man-made peninsula on the east bank of the Delaware River and was created by the deposition of hydraulic fill from dredging operations.

It is located in Lower Alloways Creek Township, Salem County, New Jersey.

The environment surrounding Artificial Island is characterized mainly by the Delaware River and Bay, extensive tidal marsh-lands, and low-lying meadowlands.

These land types make up approximately 85% of the land area within five miles of the site.

Most of the remaining land is used for agriculture [5,6].

More specific information on the demography, hydrology, meteorology, and land use of the area may be found in the Environmental Reports [5,6], Environmental statements [7,8], and the Updated Final Safety Analysis Report for SGS [9] and the Final Safety Analysis Report for HCGS [10].

Since 1968, an off-site Radiological Environmental Monitoring Program (REMP) has been conducted at the Artificial Island Site.

Starting in December, 1972, more extensive radiological monitoring programs were initiated.

The operational REMP was initiated in December, 1976, when Salem Unit 1 achieved criticality.

The PSE&G Research and Testing Laboratory (RTL),

has been involved in the REMP since its inception.

The RTL is responsible for the collection of all radiological environmental samples, and, from 1973, through June, 1983, conducted a quality assurance program in which duplicates of a portion of those samples analyzed by the primary laboratory were also analyzed by the RTL.

From January, 1973, through June, 1983, Radiation Management Corporation (RMC) had primary responsibility for the analysis of all samples under the Artificial Island REMP and the annual reporting of results.

RMC reports for the the preoperational and operational phase of the program are referenced in this report [1-3].

On July 1, 1983, the RTL assumed primary responsibility for the analysis of all samples (except TLDs) and the reporting of results.

Teledyne Isotopes (TI), Westwood, NJ, at that time was made responsible for third-party QA analyses and TLDs.

An additional vendor, Controls for Environmental Pollution Inc. has been retained to provide third-party QA analyses and certain non-routine analyses.

RTL reports for the operational phase from 1983 to 1989 are referenced in this report [4].

18

An overview of the 1990 Program is provided in Table 2.

Radio-analytical data from samples collected under this program were compared with results from the preoperational phase.

Differ-ences between these periods were examined statistically, where applicable, to determine the effects, if any, of station operations.

This report summarizes the results from January 1 through December 31, 1990, for the Artificial Island Radiological Environmental Monitoring Program.

OBJECTIVES The objectives of the Operational Radiological Environmental Monitoring Program are:

To fulfill the obligations of the Radiological surveil-lance sections of the Technical Specifications for the Salem Generating Station (SGS) and the Hope Creek Generating Station (HCGS).

To determine whether any significant increase occurs in the concentration of radionuclides in critical pathways.

To determine if SGS or HCGS has caused an increase in the radioactive inventory of long-lived radionuclides.

To detect any change in ambient gamma radiation levels.

To verify that SGS and HCGS operations have no detrimental effects on the health and safety of the public or on the environment.

This report, as required by Section 6.9.1.10 of the Salem Technical Specifications, and Section 6.9.1.7 of the Hope Creek Technical Specifications, summarizes the findings of the 1990 REMP.

Results of the four-year preoperational program which was conducted prior to the operation of any reactors on the Artif i-cial Island have been summarized for purposes of comparison with subsequent operational reports [2].

In order to meet the stated objectives, an appropriate oper-ational REMP was developed.

Samples of various media were selected to obtain data for the evaluation of the radiation dose to man and other organisms.

The selection of sample types was based on: (1), established critical pathways for the transfer of radionuclides through the environment to man, and, (2), experi-ence gained during the preoperational phase.

Sampling locations were determined from site meteorology, Delaware estuarine hydrology, local demography, and land uses.

19

Sampling locations were divided into two classes, indicator and control.

Indicator stations are those which are expected to manifest station effects, if any exist; control samples are collected at locations which are believed to be unaffected by station operations.

Fluctuations in the levels of radionuclides and direct radiation at indicator stations are evaluated with respect to analogous fluctuations at control stations.

Indica-tor and control station data are also evaluated relative to preoperational data.

Appendix A describes and summarizes, in accordance with Section 6.9.1.10 of the Salem TS and Section 6.9.1.7 of the Hope Creek TS, the entire operational program as performed in 1990.

Appendix B describes the coding system which identifies sample type and location.

Table B-1 lists the sampling stations and the types of samples collected at each station.

These sampling stations are indicated on maps B-1 and B-2.

DATA INTERPRETATION Results of all analyses were grouped according to the analysis performed for each type of sample and are presented in the data tables in Appendix c.

All results above the lower limit of detection (LLD) are at a confidence level of 2 sigma.

This represents the range of values into which 95% of repeated analyses of the same sample should fall.

As defined in Regula-tory Guide 4.8, LLD is the smallest concentration of radioactive material in a sample that will yield a net count (above system background) that will be detected with 95% probability, with only 5% probability of falsely concluding that a blank observa-tion represents a "real signal".

LLD is normally calculated as 4.66 times one standard deviation of the background count, or of the blank sample count, as appropriate.

The grouped data were averaged and standard deviations calcu-lated in accordance with Appendix B of Reference 16.

Thus, the 2 sigma deviations of the averaged data represent sample and not analytical variability.

For reporting and calculation of averages, any result occurring at or below the lower limit of detection is considered to be at that limit.

When a group of data was composed of 50% or m9re LLD values, averages were not calculated.

Grab sampling is a useful and acceptable procedure for taking environmental samples of a medium in which the concentration of radionuclides is expected to vary slowly with time or where intermittent sampling is deemed sufficient to establish the radiological characteristics of the medium.

This method, however, is only representative of the sampled medium for that specific location and instant of time.

20

As a result, variation in the radionuclide concentrations of the samples will normally occur.

Since these variations will tend to counterbalance one another, the extraction of averages based upon repetitive grab samples is considered valid.

QUALITY ASSURANCE PROGRAM The PSE&G Research and Testing Laboratory (RTL), has a quality assurance program designed to maximize confidence in the analytical procedures used.

Approximately 20% of the total analytical effort is spent on quality control, including process quality control, instrument quality control, interlaboratory cross-check analyses, and data review.

The analytical methods utilized in this program are summarized in Appendix D.

The quality of the results obtained by the RTL is insured by the implementation of the Quality Assurance Program as described in the Environmental Division Quality Assurance Plan [17] and the Chemical/ Environmental Division Procedures Manual [18].

The internal quality control activity of the Laboratory includes the quality control of instrumentation, equipment and reagents; the use of reference standards in calibration, documentation of established procedures and computer programs, and analysis of duplicate and spiked samples.

The external quality control activity is implemented through participation in the USEPA Laboratory Intercomparison Studies Program.

These results are listed in Tables E-1 through E-5 in Appendix E.

RESULTS AND DISCUSSION The analytical results of the 1990 REMP samples are divided into categories based on exposure pathways: atmospheric, direct, terrestrial, and aquatic.

The analytical results for the 1990 REMP are summarized in Appendix A.

The data for individual samples are presented in Appendix c.

The data collected demonstrates that SGS Units 1 and 2 and HCGS were operated in compliance with Technical Specifications.

The REMP for the Artificial Island Site includes additional samples and analyses not specifically required by the Salem and Hope Creek Generating Stations Technical Specifications.

The*

summary tables in this report include these additional samples and analyses

  • 21

ATMOSPHERIC Air particulates were collected on Schleicher-Schuell No. 25 glass fiber filters with low-volume air samplers.

Iodine was collected from air by adsorption on triethylenediamine (TEDA) impregnated charcoal cartridges connected in series after the air particulate filters.

Air sample volumes were measured with calibrated dry-gas meters and were corrected to standard temperature and pressure.

Precipitation was collected in a Wong Laboratory Automatic Precipitation Collector having a 95 square inch collection area.

The collector is automatically covered during periods of no precipitation to exclude fallout resulting from dry deposition.

Samples were collected monthly and transferred to new poly-ethylene containers.

The collector was rinsed with distilled water to include residual particulates in the precipitation samples.

Tritium results were corrected for the tritium content of the distilled water.

Air Particulates (Tables C-1, C-2, C-3)

Air particulate samples were collected at six locations.

Each of the 318 weekly samples collected were analyzed for gross alpha (management audit analysis) and gross beta.

Quarterly composites of the weekly samples from each station were analyzed for specific gamma emitters and a single quarterly composite sample was analyzed for Sr-89 and Sr-90 as a management audit analysis.

Total data recovery for the six sampling stations during 1990 was 99.2 percent.

Gross alpha activity was detected in 198 of the indicator station samples at concentrations ranging from 0.8 x 10-3 to 5.0 x 10-3 pCi/m3.

Analysis of the 47 control station samples detected gross alpha activity levels ranging from 0.8 x 10-3 to 4.3 x 10-3 pCi/m3.

LLD sensitivities for the remaining 73 indicator and control station samples ranged from <0.7 x 10-3 to <5.0 x 10-3 pCi/m3.

Two indicator station samples analyzed by PSE&G did not meet the desired sensitivity of 2 x 10-3 pCi/m3 due to low sample volumes caused by an air sampler mal-function.

The LLD sensitivity for the samples analyzed by PSE&G were <2.7 x 10-3 and <9.8 x 10-3 pCi/m3.

One control station sample was not included in any averages since the sampling duration was too short.

Samples analyzed by Controls for Environmental Pollution Inc., as part of the interlaboratory comparison program, were all

<5.0 x 10-3 pCi/m3 and are not included in the calcula-tions for determining the yearly mean.

The maximum preoperational level detected was 7.8 x 10-3 pCi/m3

  • 22

Gross beta activity was detected in 263 of the indicator station samples at concentrations ranging from 7 x 10-3 to 48 x 10-3 pCi/m3 and in 52 control station samples from 10 x 10-3 to 46 x 10-3 pCi/m3.

The results from two indicator and one control station samples were not included in any.averages since the sampling duration was abbreviated.

The average for both indicator and control station samples was 23 x 10-3 pCi/m3.

The maximum preoperational level detected was 920 x 10-3 pCi/m3, with an average of 74 x 10-3 pCi/m3.

Gamma spectrometric analysis performed on each of the 23 quarterly composite samples indicated the presence of the naturally-occurring radionuclides Be-7 and K-40.

All other gamma emitters searched for were below LLD.

o Beryllium-7, attributed to cosmic ray activity in the atmosphere, was detected in 18 of the 19 indicator station composites at concentrations ranging from 50 x 10-3 to 120 x 10-3 pCi/m3 and in the four control station composites from 52 x 10-3 to 61 x 10-3 pCi/m3

  • The maximum preoperational level detected was 330 x 10-3 pCi/m3, with an average of 109 x 10-3 pCi/m3.

o Potassium-40, a naturally occurring radionuclide, was not detected in any of the indicator stations' composites however it was detected in one control composite sample at a concentration of 13 x 10-3 pCi/m3.

This value is within the LLD sensitivities for the remaining samples, both indicator and control, which ranged from <4.0 x 10-3 to <14 x 10-3 pCi/m3.

No preoperation data is available for comparison.

Strontium-89 and strontium-90 analyses were performed on five indicator station composites and one control station composite from the first quarter composites as management audit analyses.

o Strontium-89 was not detected in any of the six composites analyzed.

LLD sensitivities for the seven indicator station samples ranged from <0.3 x 10-3 to

<1.0 x 10-3 pCi/m3 and for the control station at

<0.3 x 10-3 pCi/m3.

The maximum preoperational level detected was 4.7 x 10-3 pCi/m3.

o Strontium-90 was detected in one of the indicator station composites analyzed in a concentration of 0.8 x 10-3 pCi/m3.

LLD sensitivities for the remaining five stations, indicator and control were

<0.2 x 10-3 pCi/m3.

The maximum preoperational level detected was 3.0 x 10-3 pCi/m3.

23

Air Iodine. (Table C-4)

Iodine in filtered air samples was collected at six locations.

Each of the 318 weekly samples was analyzed for I-131.

Iodine-131 was not detected in any of the 318 weekly samples analyzed.

LLD sensitivities for the 265 indicator station samples ranged from <3.6 x 10-3 to <24 x 10-3 pCi/m3 and for the 53 control station samples from <3.6 x 10-3 to <13 x 10-3 pCi/m3.

The maximum preopera-tional level detected was 42 x 10-3 pCi/m3.

Precipitation (Tables C-6)

Although not required by the SGS or HCGS Technical Specifi-cations, monthly precipitation samples were collected at a location in the town of Salem as management audit samples.

Each of the twelve monthly samples collected were analyzed for gross alpha, gross beta, tritium and gamma emitters.

Gross alpha activity was detected in three of the twelve samples at concentrations ranging from 1.2 to 2.1 pCi/L.

LLD sensitivities for the remaining eight samples ranged from <0.5 to <1.8 pCi/L.

The maximum preoperational level det~cted was 4.7 pCi/L.

Gross beta activity was detected in eleven of the twelve samples at concentrations ranging from 1.4 to 21 pCi/L, with an average of 4.5 pCi/L.

The maximum preoperational level detected was 71 pCi/L, with an average of 19 pCi/L.

Tritium activity was* detected in one of the twelve samples at a concentration of 150 pCi/L.

LLD sensitivities for the samples ranged from <130 to <160 pCi/L.

The maximum preoperational level detected was 610 pCi/L, with an average of 216 pCi/L.

Gamma spectrometric analysis performed on each of the monthly samples indicated the presence of the naturally-occurring radionuclide Be-7.

All other gamma emitters searched for were below LLD.

o Beryllium-7, attributed to cosmic ray activity, was detected in six samples at concentrations ranging from 33 to 160 pCi/L, with an average of 63 pCi/L.

The maximum preoperational level detected was 79 pCi/L, with an average of 29 pCi/L.

The increase in the naturally-occurring Be-7 activity over preoperational levels is most likely due to spallation reactions in the upper atmosphere and is not attributable to the operations of SGS or HCGS.

24

DIRECT RADIATION Ambient radiation levels in the environs were measured with energy-compensated caso4 (Dy) thermoluminescent dosimeters (TLDs) supplied and read by Teledyne Isotopes.

Packets for monthly and quarterly exposure were placed on and around the Artificial Island Site at various distances.

Direct Radiation (Tables C-7, C-8)

A total of 41 locations were monitored for direct radiation during 1990, including 6 on-site locations, 29 off-site locations within the 10 mile zone, and 6 control locations beyond 10 miles. Monthly and quarterly measurements were made at the 6 on-site stations, 15 off-site indicator stations and 3 control stations.

An additional 14 quarterly measurements were taken at schools and population centers, with 3 additional controls beyond the 10 mile zone in Delaware.

Four readings for each TLD at each location were taken in order to obtain a more statistically valid result.

For these measurements, the rad is considered equivalent to the rem, in accordance with 10CFR20.4.

o The average dose rate for the 15 monthly off-site indicator TLDs was 5.6 millirads per standard month, and the corresponding average control dose rate was 6.1 millirads per standard month.

The preoperational average monthly TLD readings was 4.6 millirads per standard month.

o The average dose rate for the 26 quarterly off-site indicator TLDs was 4.7 millirads per standard month, and the average control rate was 5.1 millirads per standard month.

The preoperational average quarterly TLD readings was 4.4 millirads per standard month.

In Figure 7, the average radiation levels are plotted for the year period through 1990.

Figure 7A shows the monthly averages of the off-site indicator stations and the control stations for 1982 through 1990.

Ambient radiation levels during 1990 were comparable to those obtained during 1989.

TERRESTRIAL Milk samples were taken semi-monthly when cows were on pasture and monthly when cows were not grazing on open pasture.

Samples were collected in new polyethylene containers and transported in ice chests with no preservatives added.

25

Well water samples were collected monthly by PSE&G personnel.

Separate raw and treated potable water samples were composited daily by personnel of the City of Salem water treatment plant.

All samples were collected in new polyethylene containers.

Locally grown vegetable and fodder crops are collected once a year at time of harvest.

Such samples are weighed in the field at time of pickup and then packed in plastic bags.

Grass or green chop is collected from grazing areas, where possible.

Beef is collected semi-annually, when possible, from farm animals at time of slaughter.

The meat is weighed, then packed in plastic bags and kept chilled in ice chests during transport.

Game (muskrat) is collected annually (time of year dependent on weather conditions, which affect pelt thickness) from local farms after being trapped, stripped of their pelts and gutted.

  • The carcasses are packed in plastic bags and kept chilled in ice chests during transport.

Milk (Tables C-9, C~10)

Milk samples were collected at four local dairy farms.

Samples were collected semi-monthly when cows were on pasture and monthly when cows were not on pasture.

Animals are considered on pasture from April to November of each year.

Each sample was analyzed for I-131 and gamma emitters. In addition, although not specifically required by the SGS and HCGS Technical Specif i-cations, one sample from each location was analyzed for Sr-89 and Sr-90 in order to maintain the data base developed in prior years.

Iodine-131 was not detected in any of the 80 samples analyzed.

LLD sensitivities for the 60 indicator station samples ranged from <0.1 to <0.5 pCi/L and for the 20 control station samples from <0.1 to <0.5 pCi/L.

The maximum preoperational level detected was 65 pCi/L which occurred following a period of atmospheric nuclear weapons tests.

Gamma spectrometric analysis performed on each of the 80 samples indicated the presence of the naturally-occurring radionuclides K-40 and Ra-226.

All other gamma emitters searched for were below LLD.

o Potassium-40 was detected in all 80 samples.

Concentra-tions for the 60 indicator station samples ranged from 1100 to 1800 pCi/L.

The 20 control station sample concentrations ranged from 1200 to 1800 pCi/L.

The average for all the stations, indicator and control, was 1400 pCi/L.

The maximum preoperational level detected was 2000 pCi/L, with an average of 1437 pCi/L.

26

o Radium-226 was detected in only one sample, from an indicator station at a concentration of 20 pCi/L.

LLD sensitivities for the remaining 79 samples ranged from

<2.9 to <12 pCi/L.

The maximum preoperational level detected was <30 pCi/L.

strontium-89 and strontium-90 analyses were performed on three indicator station samples and one control station sample from the second sampling period in June as management audit samples.

o Strontium-89 was not detected in any of the three indicator samples analyzed nor in the control station sample.

LLD sensitivities for the indicator samples ranged from <1.0 to <1.3 pCi/L and for the control station at <1.2 pCi/L.

The maximum preoperational level detected was 14 pCi/L.

o Strontium-90 was detected in all of the three indicator samples analyzed.

Average concentrations for the indicator station samples was 2.8 pCi/L and for the control station sample at 3.0 pCi/L.

The average concentration for all samples was 2.8 pCi/L.

The maximum preoperational level detected was 12 pCi/L, with an average of 3.5 pCi/L.

The presence of Sr-90 in the samples can be attributed to fallout from nuclear weapons testing.

Well Water

{Tables C-11, C-12, C-13)

Although wells in the vicinity of the Salem and Hope Creek Generating Station are not directly affected by plant operations, water samples were collected monthly from one indicator well and one control well during January through December of the year.

Each sample was analyzed for gross alpha, gross beta, potassium-40, tritium, I-131 and gamma emitters.

Quarterly composites were analyzed for Sr-89 and Sr-90.

Gross alpha activity was detected in one of the indicator station samples at a concentration of 0.6 pCi/L and in one of the control station samples at 0.8 pCi./L.

These values are within the variations of the LLD sensitivities for the remaining 22 samples which ranged from <0.7 to <1.8 pCi/L.

The maximum preoperational level detected was 9.6 pCi/L.

Gross beta activity was detected in all 24 samples.

Concentrations for the 12 indicator station samples ranged from 2.5 to 9.9 pCi/L and for the 12 control station samples from 7.7 to 11 pci/L.

The average concentration detected for all samples was 6~9 pCi/L.

The maximum preoperational level detected was 38 pCi/L, with an average of 9 pCi/L.

27

Potassium-40 activity (determined by atomic absorption) was detected in all 24 samples.

Concentrations for the 12 indicator station samples ranged from 2.6 to 7 pCi/L and for the 12 control station samples from 8.1 to 12 pCi/L.

The average concentration detected for all samples was 6.7 pCi/L.

The maximum preoperational level detected was 19 pCi/L, with an average of 7.8 pCi/L.

Tritium activity was not detected in any of the indicator station samples nor in any of the control station samples.

The LLD sensitivities for the 24 samples ranged from <130 to <160 pCi/L.

The maximum preoperational level detected was 380 pCi/L.

Gamma spectrometric analysis performed on each of the 12 indicator station and 12 control station water samples indicated the presence of the naturally-occurring radio-nuclides K-40 and Ra-226.

All other gamma emitters searched for were below LLD.

o Potassium-40 was detected in one sample from the indicator station with a concentration of 53 pCi/L, and in four control station samples with a concentration between 52 to 88 pCi/L.

The maximum preoperational level detected was 30 pCi/L.

o Radium-226 was detected in four of the indicator station samples at concentrations ranging from 7.6 to 9.8 pCi/L and in all twelve control station samples from 19 to 220 pCi/L.

LLD sensitivities for the remaining indicator station samples ranged from <2.5 to <7.5 pCi/L. The maximum preoperational level detected was 2.0 pCi/L.

These values are similar to those found last year.

However, as with the 1989 results, they are higher values than found in the preoperational program.

We believe that results are higher due to a procedural change in which the samples are no longer boiled down to a 100 ml standard geometry.

This change results in less removal of radon (and its daughters) from the sample.

since Ra-226 is an alpha emitter, its identification by gamma isotopic analysis is obtained by counting the gamma rays from Pb-214, one of its daughter products.

We believe that values currently being observed are typical for this geographical area.

Strontium-89 and strontium-90 analyses were performed on quarterly composites of the monthly well water samples.

o strontium-89 was not detected in any of the four indicator station or four control station composites.

LLD sensitivities for the indicator samples ranged from 28

0

<0.6 to <1.4 pCi/L and for the control samples from <0.5 to <0.8 pCi/L.

The maximum preoperational level detected was <2.1 pCi/L.

Strontium-90 was not detected in any of the four indicator station or four control station composites.

LLD sensitivities for indicator samples ranged from <0.5 to <1.0 pCi/L and for the control samples from <0.4 to

<0.6 pCi/L.

The maximum preoperational level detected was 0.87 pCi/L.

I-131 was not detected in any of the twelve indicator station samples or control station samples.

LLD sensi-tivities for all the stations, indicator and control samples, ranged from <0.1 to <0.4 pCi/L.

Potable Water (Tables C-14, C-15, C-16)

Both raw and treated potable water samples were collected from the Salem water treatment plant.

Each consisted of daily aliquots composited into a monthly sample.

The raw water source for this plant is Laurel Lake and adjacent wells.

Each of the 24 individual samples was analyzed for gross alpha, gross beta, K-40, tritium, iodine-131 and gamma emitters.

Quarterly composites of monthly raw and treated water samples were analyzed for Sr-89 and Sr-90.

Gross alpha activity was detected in three raw water samples at concentrations ranging from 1.1 to 1.7 pCi/L and in two treated water samples both 1.1 pCi/L.

These values are within the variations of the LLD sensitivities for the remaining 19 samples which ranged from <0.8 to <2.1 pci/L.

The maximum preoperational level detected was 2.7 pCi/L.

Gross beta activity was detected in all 24 samples at concentrations ranging from 2.4 to 6.4 pCi/L for the raw water and from 2.2 to 3.9 pCi/L for treated water.

The average concentration for both raw and treated was 3.2 pCi/L.

The maximum preoperational level detected was 9.0 pCi/L, with an average of 4.2 pCi/L.

Potassium-40 activity (determined by atomic absorption) was detected in all 24 samples at concentrations ranging from 1.4 to 2.7 pCi/L for the raw water and from 1.4 to 3.0 pCi/L for treated water.

The average concentration for both raw and treated was 2.2 pCi/L.

The maximum preopera-tional level detected was 10 pCi/L, with an average of 1.7 pCi/L

  • 29

Tritium activity was only detected in two raw water samples at concentrations of 140 to 160 pCi/L.

LLD sensitivities for the remaining 22 samples ranged from <130 to <170 pCi/L.

The maximum preoperational level detected was 350 pCi/L, with an average of 179 pCi/L.

Iodine-131 measurements to a sensitivity of 1.0 pCi/L were performed.

Since the receiving water body is brackish, the water is not used for human consumption.

Drinking water supplies are not affected by discharges from the site.

Iodine-131 measurements were below the LLD sensitivities.

The LLD sensi ti vi tes ranged from <O. 1 to <O. 8..

Gamma spectrometric analysis performed on each of the 24 monthly raw and treated potable water samples indicated the presence of the naturally-occurring radionuclides, K-40 and Ra-226.

All other gamma emitters searched for were below LLD.

o Although not as sensitive as atomic absorption, K-40 was detected in one sample at a concentration of 54 pCi/L.

All other results were below LLD.

The LLD sensitivities ranged from <13 to <47 pCi/L.

No preoperation data is available for comparison.

Since the gross beta result and K-40 determination by AA does not corroborate the above result, it is postulated that the sample container may have become contaminated with a trace level of potassium.

o Radium-226 was not detected in any of the raw water samples and at a concentration of 24 pCi/L in one treated water sample.

LLD sensitivities measured throughout the year for the remaining 21 raw and treated samples ranged from <2.0 to <6.3 pCi/L.

The maximum preoperational level detected was 1.4 pCi/L.

Strontium-89 and strontium-90 analyses were performed on quarterly composites of the daily raw and treated water samples.

o Strontium-89 was not detected in any of the four raw or treated water composites.

LLD sensitivities for the raw water sample composites ranged from <0.8 to <l.O pCi/L and for the ~reated water sample composites from <0.6 to

<0.9 pCi/L.

The maximum preoperational level detected was L 1 pCi/L.

o strontium-90 was not detected in any of the four raw or treated water sample composites.

LLD sensitivities for the four treated water sample composites ranged from

<0.6 to <0.9 pCi/L and for the raw water sample composites from <0.7 to <l.O pCi/L.

The maximum preoperational level detected was 2.1 pCi/L.

30

Vegetables (Table C-17)

Although vegetables in the region are not irrigated with water into which liquid plant effluents have been discharged, a variety of food products grown in the area for human consumption were sampled at seven indicator stations (10 samples) and three control stations (7 samples).

The vegetables collected as management audit samples are analyzed for gamma emitters and included asparagus, cabbage, sweet corn, peppers and tomatoes.

Gamma spectrometric analysis performed on each of the seventeen samples indicated the presence of the naturally-occurring radionuclide K-40.

All other gamma emitters searched for were below LLD.

o Potassium-40 was detected in all seventeen samples.

Concentrations for the ten indicator station samples ranged from 1600 to 3100 pCi/kg-wet and for the seven control station samples from 1800 to 2500 pCi/kg-wet.

The average concentration detected for all samples was 2100 pCi/kg-wet.

The maximum preoperational level detected was 4800 pCi/kg-wet, with an average of 2140 pCi/kg-wet.

Game (Table C-18)

Although not required by the SGS or HCGS Technical Specifi-cations, samples of muskrats inhabiting the marshlands surrounding the site are collected. This game is consumed by local residents.

The samples, when available, are collected from two locations once a year as management audit samples and analyzed for gamma emitters.

Samples from two locations were collected during the end of January and beginning of February to satisfy this requirement.

Gamma spectrometric analysis of the flesh indicated the presence of the naturally-occurring radionuclide K-40.

All other gamma emitters searched for were below LLD.

o Potassium-40 was detected in the indicator station sample at a concentration of 2700 pCi/kg-wet and the control station sample at 2300 pCi/kg-wet.

The average for both muskrat samples was 2500 pCi/kg-wet.

The maximum preoperational level detected was 27000 pCi/kg-wet, with an average of 4400 pCi/kg-wet.

Fodder Crops (Table C-19)

Although not required by the SGS or HCGS Technical Specifi-cations, eight samples of crops normally used as cattle feed 31

were collected from four indicator stations (6 samples) and one control station (2 samples). It was determined that these products may be a significant element in the food-chain pathway.

Fodder crops are collected as management audit samples and analyzed for gamma emitters.

Four of the locations from which samples were collected are milk sampling stations.

Samples collected for wet gamma analysis included corn silage,green chop, and soybeans.

Gamma spectrometric analysis performed on each of the eight samples indicated the presence of the naturally-occurring radionuclides Be-7 and K-40.

All other gamma emitters searched for were below LLD.

o Beryllium-7, attributed to cosmic ray activity in the atmosphere, was detected in the one green chop sample at a concentration of 650 pCi/kg-wet.

The three corn silage samples from the indicator stations were at concentrations ranging from 460 to 540 pCi/kg-wet and in the control station silage sample at 600 pCi/kg-wet.

LLD sensitivities for the remaining two indicator soybean samples ranged from <30 to <60 pCi/kg-wet.

The control station soybean sample was <70 pCi/kg-wet.

The maximum preoperational level detected was 4700 pCi/kg-wet, with an average of 2000 pCi/kg-wet.

o Potassium-40 was detected in all eight samples.

AQUATIC Concentrations for the six indicator station samples ranged from 3000 to 14000 pCi/kg-wet and for the two control station samples at 3200 to 14000 pCi/kg-wet.

The average concentration detected for all samples was 13000 pCi/kg-wet.

These levels are comparable to preoperational results, which also detected a maximum level of 16000 pCi/kg-wet with an average of 7000 pci/kg-wet.

All aquatic samples were collected by Environmental Consulting Services, Inc. and delivered by PSE&G personnel.

Surface water samples were collected in new polyethylene containers which were rinsed twice with the sample medium prior to collection.

Edible fish and crabs were taken by net and frozen in sealed poly-ethylene containers before being transported in ice chests.

Sediment samples were taken with a bottom grab sampler and frozen in sealed polyethylene containers before being transported in ice chests.

32

Surface Water (Tables C-20, C-21, C-22, C-23)

Surface water samples were collected monthly at four indicator stations and one control station in the Delaware estuary.

One location is at the outfall area (which is the area where liquid effluents from the Salem Station are discharged into the Delaware River), another is downstream from the outfall area, and another is directly west of the outfall area at the mouth of the Appoquinimink River.

Two upstream locations are in the Delaware River and at the mouth of the Chesapeake and Delaware Canal, the latter being sampled when the flow is from the canal into the river.

Station 12C1, at the mouth of the Appoquinimink River, serves as the operational control.

All surface water samples were analyzed monthly for gross alpha, gross beta, I-131 and gamma emitters.

Quarterly composites were analyzed for tritium.

Gross alpha activity was detected in nine samples from the 48 indicator stations at concentrations ranging from 1.2 to 2.1 pCi/L and in four control station samples ranging from 1.0 to 2.3 pCi/L.

These values are within the variations of the LLD sensitivities for the remaining samples which ranged from <1.0 to <4.1 pCi/L.

The maximum preoperational level detected was 27 pCi/L.

Gross beta activity was detected in all of the 60 samples.

Concentrations for the 48 indicator station samples ranged from 5.4 to 110 pCi/L and for the 12 control station samples from 15 to 79 pCi/L.

The average concentration detected for all samples, indicator and control, was 44 pCi/L.

The maximum preoperational level detected was 110 pCi/L, with an average of 32 pCi/L.

Tritium activity was detected in four samples from the four indicator station composites at concentrations ranging from 150 to 230 pCi/L.

Concentrations were detected in two of the control station composites at 160 pCi/L.

LLD sensi-tivities for the remaining composites ranged from <140, to

<170 pCi/L.

The maximum preoperational level detected was 600 pCi/L, with an average of 210 pCi/L.

Iodine-131 was not detected in any of the 48 indicator station or 12 control station surface water samples.

LLD concentrations ranged from <0.1 to <0.8 pCi/L for the indicator stations and <0.2 to <0.9 pCi/L for the control station samples.

No preoperational data is available for comparison.

Gamma spectrometric analysis performed on each of the 48 indicator station and 12 control station surf ace water samples indicated the presence of the naturally-occurring radionuclides K-40 and Th-232.

All other gamma emitters searched for were below LLD.

33

o Potassium-40 was detected in 33 samples from the indicator station samples at concentrations ranging from 31 to 170 pCi/L and in eight of the control station samples ranging from 52 to 140 pCi/L.

The averages for all the locations was 66 pCi/L.

LLD sensitivities measured throughout the year for the remaining samples ranged from <18 to <55 pCi/L.

The maximum preoperational level detected was 200 pCi/L, with an average of 48 pCi/L.

o Thorium-232 was detected in one sample out of the 48 indicator stations at a concentration of 4.7 pCi/L.

This value is within the variations of the LLD sensitivities for all remaining samples measured throughout the year which ranged from <2.6 to <6.2 pCi/L.

No preoperational data is available for comparison.

However, the presence of Th-232 is not attributable to the operations of SGS or HCGS.

Fish (Table C-24)

Edible species of fish were collected semi-annually at three locations and analyzed for tritium (aqueous), gamma emitters (flesh), and for Sr-89 and Sr-90 (bones & flesh).

Samples included bluefish, channel catfish, weakfish and white perch.

Tritium analysis was performed on the aqueous fraction of the flesh portions of each of the two indicator station and one control station samples as management audit analysis.

No tritium activity was detected in any of the six samples analyzed; LLD sensitivity was <200 to <1000 pCi/kg-wet.

The maximum required LLD sensitivity value is 2000 pCi/kg-wet.

Gamma spectrometric analysis performed on each of the four indicator station samples and two control station samples indicated the presence of the naturally-occurring radio-nuclides K-40 and Ra-226.

All other gamma emitters searched for were below LLD.

o Potassium-40 was detected in all tour samples from the two indicator stations at concentrations ranging from 3100 to 3600 pCi/kg-wet and in both of the control station samples at 3000 and 3100 pCi/kg-wet.

The average for both the indicator and control station samples was 3200 pCi/kg-wet.

The maximum preoperational level detected was 13000 pCi/kg-wet, with an average of 2900 pCi/kg-wet.

o Radium-226 was detected in one of the indicator station samples at a concentration of 32 pCi/kg-wet and not in either control station.

The LLD sensitivities for the remaining samples, both indicator and control, ranged 34

from <7.9 to <20 pCi/kg-wet.

No preoperational data is available for comparison.

However, the presence of Ra-226 is not attributable to the operations of SGS or HCGS.

Strontium-89 and strontium-90 analyses were performed on each of the four indicator station and two control station samples.

These are management audit analyses analyzed in recognition of the high bioaccumulation factor of strontium in bone.

o Strontium-89 of the bone was not detected in any of the six indicator and control station samples.

LLD sensi-tivities for the six samples, indicator and control, ranged from <29 to <73 pCi/kg-dry.

The maximum preoper-ational level detected was 100 pCi/kg-dry.

o Strontium-90 of the bone was detected in three of the four indicator station samples and in both control station samples.

Concentrations in the four indicator samples ranged from 45 to 280 pCi/kg-dry, with an average of 192 pCi/kg-dry.

Concentrations in the two control samples were 25 and 320 pCi/kg-dry, with an average of 173 pCi/kg-dry.

The average for all samples was 1*60 pCi/kg-dry.

The maximum preoperational level detected was 940 pCi/kg-dry, with an average of 335 pCi/kg-dry.

The presence of Sr-90 in the samples can be attributed to fallout from nuclear weapons testing.

o Strontium-89 of the flesh was not detected in any of the six indicator and control station samples.

LLD sensi-tivities for the six samples, indicator and control, ranged from <25 to <34 pCi/kg-wet.

The preoperational level ranged from <4.1 to <100 pCi/kg-wet.

o Strontium-90 of the flesh was not detected in any of the six indicator and control station samples.

LLD sensi-tivities for the six samples, indicator and control, ranged from <19 to <26 pCi/kg-wet.

The maximum preoperational level detected was 67 pCi/kg-wet.

Blue Crab (Table C-25)

Blue crab samples were collected semi-annually at two locations, one indicator and one control, and the edible portions were analyzed for gamma emitters, Sr-89 and Sr-90, and tritium in the aqueous fraction. The shells were also analyzed for Sr-89 and Sr-90.

Tritium analysis was performed on the aqueou~ fraction of the flesh portions of each of the two indicator samples and

two control samples as management audit analysis.

Tritium activity was detected in one of the indicator station samples with a concentration of 700 pCi/kg-wet and in none of the control station samples.

LLD sensitivities for the four samples, indicator and control, were <1000 pCi/kg-wet.

The maximum required LLD sensitivity value is 2000 pCi/kg-wet.

The maximum preoperational level detected was 320 pCi/kg-wet.

o Gamma spectrometric analysis on the flesh of each of the two indicator station samples and two control station samples indicated the presence of the naturally-occurring radionuclide K-40.

All other gamma emitters searched for were below LLD.

o Potassium-40 was detected in both indicator station samples at concentrations of 2300 and 2800 pCi/kg-wet and in both of the control station samples at 2000 and 2700 pCi/kg-wet.

The average for both the indicator and control station samples was 2400 pCi/kg-wet.

The maximum preoperational level detected was 12000 pCi/kg-wet, with an average of 2835 pCi/kg-wet.

Strontium-89 and strontium-90 analyses were performed on the flesh and shell of each of the indicator station and control station samples, as management audit analyses.

Strontium analysis of the shell is performed because of the reconcentration factor of strontium in crab shells.

o Strontium-89 of the flesh was detected in one of the four samples, indicator and control, at 32 pCi/kg-wet.

LLD sensitivities for the remaining samples ranged from

<21 to <28 pCi/kg-wet.

The maximum preoperational level detected was <51 pCi/kg-wet.

o strontium-89 of the shell was not detected in any of the indicator or control station samples.

The LLD sensitivity for the samples, indicator and control, ranged from <36 to <52 pCi/kg-dry.

The maximum required LLD sensitivity value is 500 pCi/kg-dry.

The maximum preoperational level detected was 210 pCi/kg-dry.

o Strontium-90 of the flesh was not detected in any of the four, indicator or control samples.

LLD sensitivities ranged from <18 to <20 pCi/kg-wet.

The maximum preoperational level detected was <150 pCi/kg-wet.

o Strontium-90 of the shell was detected in both indicator station samples at 220 and 230 pCi/kg-dry and in both control station samples at 340 and 670 pCi/kg-dry.

The average for both indicator and control station samples was 360 pCi/kg-dry.

The maximum preoperational level 36

detected was 990 pCi/kg-dry, with an average of 614 pCi/kg-dry.

The presence of Sr-90 can be attributed to fallout from weapons testing or fallout from the Chernobyl accident.

Sediment (Table C-26)

Sediment samples were collected semi-annually from six locations, five indicator stations and one control station.

Each of the twelve samples was analyzed for Sr-90 (management audit analysis) and gamma emitters.

Although trace levels of man-made nuclides were detected in some sediment samples, these levels were well within the acceptable levels specified in section 3/14.12.1 of the Technical Specifications.

Strontium-90 was not detected in any of the twelve indi-cator and control station samples.

LLD sensitivities for these samples ranged from <19 to <25 pCi/kg-dry.

The maximum preoperational level detected was 320 pCi/kg-dry.

Gamma spectrometric analysis was performed on each of the ten indicator station samples and two control station samples.

In addition to the detection of the naturally-occurring radionuclides K-40, Ra-226 and Th-232, low levels of Mn-54, Co-58, Co-60, and Cs-137 were also detected.

All other gamma emitters searched for were <LLD.

o Cobalt-60 was detected in four of the ten indicator stations at concentrations ranging from 42 to 87 pCi/kg-dry.

It was not detected at either of the two control stations.

LLD sensitivities for the other six samples, indicator and control, ranged from <10 to <54 pCi/kg-dry.

No preoperational data is available for comparison.

o Manganese-54 was detected in three of the ten indicator stations at concentrations ranging from 28 and 48 pCi/kg-dry.

These values are within the variations of the LLD sensitivities for the other nine samples, indicator and control, which ranged from <6 to <21 pCi/kg-dry.

No preoperational data is available for comparison.

o Cobalt 58 was detected in three indicator station samples at concentrations ranging from 28 to 230 pCi/kg-dry.

The LLD sensitivities for the other nine samples, indicator and control, ranged from <11 to <35 pCi/kg-dry.

No preoperational data is available for comparison

  • 37

o Cesium-137 was detected in six indicator station samples at a concentration ranging from 27 to 74 pCi/kg-dry.

The LLD sensitivities for the other six samples, indi-cator and control, ranged from <5.5 to <18 pCi/kg-dry.

The maximum preoperational level detected was 400 pCi/kg-dry.

o Potassium-40 was detected in all indicator station samples at concentrations ranging from 2700 to 16000 pCi/kg-dry, with an average of 8600 pCi/kg-dry.

Concen-trations detected in both of the control station samples were at 17000 pCi/kg-dry.

The average for both the indicator and control station samples was 10000 pCi/kg-dry.

The maximum preoperational level detected was 21000 pCi/kg-dry, with an average of 15000 pCi/kg-dry.

0 0

Radium-226 was detected in all indicator station samples at concentrations ranging from 120 to 1300 pCi/kg-dry, with an average of 570 pCi/kg-dry.

Concentrations detected in both of the control station samples were at 560 and 640 pCi/kg-dry, with an average of 600 pCi/kg-dry.

The average for both the indicator and control station samples was 580 pCi/kg-dry.

The maximum preoperational level detected was 1200 pCi/kg-dry, with an average of 760 pCi/kg-dry.

Thorium-232 was detected in all indicator station samples at concentrations ranging from 120 to 890 pCi/kg-dry, with an average of 650 pCi/kg-dry.

Concentrations detected in both of the control station samples were at 940 and 990 pCi/kg-dry, with an average of 965 pCi/kg-dry.

The average for both the indicator and control station samples was 700 pCi/kg-dry.

The maximum preoperational level detected was 1300 pCi/kg-dry, with an average of 840 pCi/kg-dry.

38

PROGRAM DEVIATIONS Air particulate and iodine filter from location 2F2 became separated beginning week of January 29.

Results were invalid for the air particulate filter as it was only attached for 1 day out of a 7 day sampling period.

Air particulate and iodine sampler location 1F1 for the week beginning February 13, was operational for only 6 days out a 7 day sampling period due to an instrument malfunction.

Air particulate and iodine sampler location 1F1 for the week beginning February 20, was operational for only 2 days out of a 6 day sampling period due to an instrument malfunction.

Air particulate and iodine sampler location 3H3 for the week beginning October 1, was operational for only 6 1/4 days out of an 8 day sampling period due to an instrument malfunction.

Air particulate and iodine sampler location 2F2 for the week beginning October 22, was operational for only 5 days out of a 7 day sampling period due to an instrument malfunction.

Air particulate and iodine filter from location 3H3 became separated the week beginning December' 3. Results were invalid for the air particulate filter as it was only attached for 1 day out of a 7 day sampling period.

Although not required by Technical Specifications, beef samples are normally collected twice each year.

However, due to uncertain availability of the sample, no beef samples were obtained in 1990.

The results from four quarterly TLDs collected and delivered to the vendor laboratory during the second quarter of 1990 are missing.

The TLDs from these stations were presumed lost.

A discussion of this matter has resulted in a change to the packing list to incorporate a verification of the TLD number plus a notification of any discrepancies within two working days of sample receipt.

Gamma isotopic analysis was not performed on the composite air filters from location 501 during the second quarter of 1990 by the vendor laboratory.

A letter restating that gamma isotopic analysis is to be performed on all quarterly composited air filters as required by Technical Specifications, was sent to the vendor laboratory

  • 39

CONCLUSIONS The Radiological Environmental Monitoring Program for Artificial Island was conducted during 1990 in accordance with the SGS and HCGS Technical Specifications.

The objectives of the program wer~ met during this period.

The data collected assists in demonstrating that SGS Units One and Two and HCGS were operated in compliance with Technical Speci_fications.

From the results obtained, it can be concluded that the levels and fluctuations of radioactivity in environmental samples were as expected for an estuarine environment.

These results were comparable to the results obtained during the preoperational phase of the program.

Ambient radiation levels, as determined by TLDs collected monthly were relatively low, averaging 5.9 mrad/std. month.

No unusual radiological characteristics were observed in the environs of Artificial Island.

The operation of SGS Units One and Two and HCGS had no significant impact on the radiological characteristics of the environs of Artificial Island.

40

TABLE 2 1989 ARTIFICIAL ISLAND RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM MEDIUM I.

ATMOSPHERIC ENVIRONMENT

a.

Air Particulate

b.

Air Iodine

c.

Precipitation II.

DIRECT RADIATION

a.

Thermoluminescent Dosimeters SSl SSl 2S2 SSl 6S2 781 lOSl llSl STATION CODE INDICATOR CONTROL SDl 16El lFl 2F2 SDl 16El lFl 2F2 2F2 SDl 2El lFl lODl 3El 2F2 14Dl 13El 2F6 16El SFl 6Fl 7F2 llFl 13F4 3H3 3H3 3Gl 3Hl 3H3 COLLECTION FREQUENCY Weekly Weekly Monthly Monthly &

Quarterly TYPE/FREQUENCY* OF ANALYSIS Gross alpha/weekly Gross beta/weekly Sr-89 & sr-90/first quarter**

Gamma scan/quarterly Iodine-131/weekly Gross alpha/monthly Gross beta/monthly Tritium/monthly Gamma scan/monthly Gamma dose/monthly Gamma dose/quarterly

TABLE 2 (cont'd) 1989 ARTIFICIAL ISLAND RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM STATION CODE COLLECTION MEDIUM INDICATOR CONTROL FREQUENCY TYPE/FREQUENCY* OF ANALYSIS

a.

Thermoluminescent 4D2 9El 2F5 1G3 Quarterly Gamma dose/quarterly Dosimeters (cont'd) 11E2 3F2 lOGl 12El 3F3 16Gl 10F2 12Fl 13F2 13F3 14F2 15F3 16F2 ii=>-

N III.

TERRESTRIAL ENVIRONMENT

a.

Milk 2F7 3Gl Monthly Iodine-131/monthly (when animals Gamma scan/monthly 11F3 are not on pasture) 14Fl Semi-monthly Iodine-131/semi-monthly (when animals Gamma scan/semi-monthly are on Sr-89 & Sr-90/July, first pasture) collection **

b.

Well Water 2S3 3El Monthly Gross alpha/monthly Gross beta/monthly Potassium-40/monthly Tritium/monthly Gamma scan/monthly Sr-89 & Sr-90/quarterly

  • TABLE 2 (cont'd) 1989 ARTIFICIAL ISLAND RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM STATION CODE COLLECTION MEDIUM INDICATOR CONTROL FREQUENCY TYPE/FREQUENCY* OF ANALYSIS
c.

Potable Water 2F3 Monthly Gross alpha/monthly (Raw & Treated)

(composited Gross beta/monthly daily)

Potassium-40/monthly Tritium/monthly Gamma scan/monthly sr-89 & sr-90/quarterly

d.

Vegetables 2F4

-lGl 3H5 Annually Gamma scan/on collection 3E2 4F2 2Gl (at harvest)

.i:.

w 11E3 SFl 14F3

e.

Beef 3El Semi-Gamma scan/on collection annually

f.

Game 3El llDl Semi-Gamma scan/on collection (Muskrat) annually

g.

Fodder Crops 4D2 3El 2F7 3Gl Annually Gamma scan/on collection 11F3 14Fl

h.

Soil 6Sl lODl 16El lFl 3Gl Collect Sr-90/on collection 2F4 from each Gamma scan/on collection 2F7 location SFl once every 11F3 three years 14Fl

TABLE 2 (cont'd) 1989 ARTIFICIAL ISLAND RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM STATION CODE COLLECTION MEDIUM INDICATOR CONTROL FREQUENCY IV.

AQUATIC ENVIRONMENT

a.
b.
c.
d.

Surface Water llAl 7El 1F2 12Cl Monthly 16Fl Edible Fish llAl 7El 12Cl Semi-annually Blue Crabs llAl 12Cl Semi-annually Sediment llAl 7El 16Fl 12Cl semi-lSAl annually 16Al

  • Except for TLDs, the quarterly analysis is performed on a composite of individual samples collected during the quarter.
    • Management audit analyses, not required by Technical Specifications or by specific commitments to local officials *
  • TYPE/FREQUENCY* OF ANALYSIS Gross alpha/monthly Gross beta/monthly Gamma scan/monthly Tritium/quarterly Tritium (flesh)

Aqueous fraction/on collection **

Sr-89 & Sr-90 (bones)/on collection sr-89 & Sr-90 (flesh)/on collection Gamma scan (fl.esh)/on collection Tritium (flesh)

Aqueous fraction/on collection **

sr-89 & sr-90 (flesh)/on collection Sr-89 & Sr-90 (shell)/on collection Gamma scan (flesh)/on collection sr-90/on collection Gamma scan/on collection

1000 -*****

100 FIGURE 6 BETA IN PRECIPITATION AND AIR PARTICULATE 1973 through 1990

          • t******/*************

I

\\

, I I

I I

LEGEND

____ AIR (fcl/m3)


PRECIPITATION PCl/L I

I

...,.~ ******;'* ~--.........................

                          • '-~***............................................................... ~\\*****************

\\

I

\\

I -

1, I

  • II,-',

,'11 I

11 ',_,'

'-,I\\ I\\

I

\\I

\\

I

\\

\\

1""', II I

I Ii

\\I

\\J

\\I I

I -

',I

\\f I I 1

1-z

<C 0 (I)

I-

!!: z Zw CJ >

(I) w 1973 fl)

G>...

fl.I c 0

D.

as G>

3:

1975 1977 fl)

Cl>

I-fn N ~ C I

0 E ~ a.

-a>:+: as

e 'ii 'i:

G>

l-U>03:

1979 1981 1983 1985 1987 1989 1991

1000 100 10 FIGURE 6A BETA IN. PRECIPITATION AND AIR PARTICULATE 1986 through 1990 LEGEND AIR (f Cl/m 3)

PRECIPITATION PCl/L

................................................................................................................. **********************************************************************-----------------~

r*

....*..... r..1..... 1\\............. 1\\..... ************************.................................................

I\\

1, 1,

I I

I

\\

I I

, \\

f\\

I II I

\\ -'

I

\\

1 1

\\

11 \\.,,.\\

I

\\

'\\

I

~ :

~

II,,

', "'\\

I

\\ I

}'.'

\\

\\

I If I I

\\

I 11

\\

I

\\

I I

\\ -

I 1

'- - , I I

I I

11 11

\\

II

'I

\\I

\\I

-.................. ********;....,.........,,.......................................... ;\\:...... '".............

1

\\

I

\\

1

\\

I \\

I

\\\\ I

\\

1

\\

I

\\

I\\

,-1

\\

If I I

\\

I I

\\\\

I

\\I

\\I

\\

I"' t I

\\

4 I

\\I

\\1 f'

I f

f I

1 ****************************************************....................................................................................................................................................................................................................................................................................

z c(

o en I-

!:!: z Zw

£! >

en w

~

~~~

o o ca E CD

()

  • a. :e

.c 0 0 :c 0 1986 1987 1988 1989 1990 1991

.c

+'

10 c

8 0

E

'a

+'

tn

......... E

~ 6 E

4 I-z

<(

o en I-

!!: z z Ill

~>

en 111 FIGURE 7 AMBIENT RADIATION - OFFSITE vs CONTROL ST A TION 1973 through 1990

+'

+'

+' +'

+'

fl) fl) tn tn fl)

G>

G>

G>

G>

Cll I-I-

I-I-I-

fl) fl)

>- tn fl) fl) c C1"'":!::CC N

c 0

01-;oo.-

0

a.

a.eua.a.

E ~ a.

('IS

('IS G> *-

('IS

('IS Cl> *-

('IS Cl>

Cl> -

Cl>

Cl>

+'

Cl>

3:

3:~03:3:

?: -; 'i:: 3:

I- (I) 0 1973 1976 1977 1979 1981 1983 1986 LEGEND

-- OFFSITE STATIONS


CONTROL STATIONS

~

Gt >-

G> +'

.a... *-

oo-c

('IS G>.!:!

  • a. :!:::::

.c 0 0 :::c 0 1987 1989 1991

.c

.... c 0 E

'O

.i:-.

al

())

E.,... E 10 t-z cs:

8 6

4 u en t-

!!: z Zw S! >

en w FIGURE 7A AMBIENT RADIATION - OFFSITE vs CONTROL STATION 1986 through 1990 1986 1987 1988 1989 LEGEND

-- OFFSITE STATIONS

- - - - - CONTROL STATIONS 1990 1991

~-----------------------------~-

6v SIGNIFICANT pCi/L EVENTS N

0 en 0

Ch 0

I I

co c.>

-a.

Weapons Test co Ch Weapons Test co

,_ Salem-1 0

Criticality ~

c Weapons Test Weapons Test z

co

..... m

'° I

co TMI Salem-2 w w Criticality

'Tl CD

r CD -

Weapons Test

""I J> G>

0 0 c:

c

-I :a ca -

m

r <

CD Q)

CD

..... -I c.>

'° -

0 z CD CD -

s:

en Chernobyl I~

r-Hope Creek I

CD -

Criticality CD co CD co CD -

co

01 0

..J ' 0 D.

FIGURE SA IODINE-131 ACTIVITY IN MILK 1986 THROUGH 1990 20..--~~~~---~~~~~~~~~~~~~~~~~~-----.,

19 -

18 -

17 -

16 ~

15 -

14 ~

13 -

12 '-

11 '-

10 -

9 -

8 -

7 -

6 -

5 -

4 -

3 '-

2 -

1 - ___ =-::-=---~====::::::::==========================:::=:::=::::::===~-_J o~

1-z c:(

() (I)

!!: z Zw

~>

(I) w 19 188 19 190

i PCi/L SIGNIFICANT 0

EVENTS 0

0 0

0 0

Q Jl 0

co en

(,.)

en Weapons Test m

co m

-I en l>

Weapons Test

$20 co Salem-1 Criticality U)

I Weapons Test

~

Weapons Test CA> 0 co....

-I l> 'Tl co TMI Salem-2

c o-

-I Q

  • Criticality Jl co 0 - c:

m Weapons Test

< :D c: -m

~ -I

c -

U) co CD

(,.)

U) z U) en 0 c:

co CD Jl en

'Tl Chernobyl l>

Hope Creek 0

co CD Criticality m

I

e r-l>

co CD "G> m

-I I

lJ G) co

~om m

0 (I) z

JJ

"°"::..;

(I) c co m

co m

-t l>

..J ' u

a.

100 FIGURE 9A GROSS BETA & K-40 ACTIVITIY IN SURFACE WATER 1986 THROUGH 1990 LEGEND GROSS BETA

...... K-40


--------- -----* ~-*-*-**---. --------- -.. ------------ -. ---- ---- --------- -- ------------- --. ---- -- ------ --. ----- -----** -------**-*.......... -----------

I I

I I

10

.... z ct u U)

!!:: z Zw

~>

U) w 1986 Jill:

>i

>i.....

.a... *-

0 '" -

c -

  • a. :!::

.c 0 u :c u 1987 1988 1990 1989 1991


~~

co en co co m

co m

en co m

co co (o)

SIGNIFICANT EVENTS Weapons Test Weapons Test Salem-1 Criticality Weapons Test C:

Weapons Test co TMI co CD (o)

Salem-2 Criticality Weapons Test Chernobyl co Hope Creek

~ Criticality co co Q

Q PCi/L Q

Q Q

Q Q

Q Q

-I

D --I -c:

s:

..... l>

~o

(.,) :::!

-I ~,,

c -I '5
D -< c:
  • 0 -

lJ c: z m Q

U>.....

c § 0

..... '11

<D l>

<D 0 Om

c l>

-I m

a

1000 FIGURE 10A TRITIUM ACTIVITY IN SURFACE WATER 1986 THROUGH 1990

...I

........ 0 100 Q.

1-z U>

"' I-

~ z IL Ill z Ill CJ -

U>

10

                                              • i******************l******** ********************************************************************************************************************************************************************.........................................................................

.a 0 c.. *

.c 0

1986 1987 1988 1990 1989 1991

[ 1]

[ 2]

[3]

REFERENCES Radiation Management Corporation.

"Artificial Island Radiological Environmental Monitoring Program - Annual Reports 1973 through 1982".

Radiation Management Corporation.

Environmental Monitoring Program -

1976".

RMC-TR-77-03, 1978.

Radiation Management Corporation.

Environmental Monitoring Program -

RMC-TR-77-02, 1977.

"Artificial Island Radiological Preoperation Summary -

1973 through "Artificial Island Radiological December 11 to December 31, 1976".

[4]

PSE&G Research Corporation, Research and Testing Laboratory.

"Artificial Island Radiological Environmental Monitoring Program -

Annual Reports 1983 through 1989".

[5]

Public Service Electric and Gas Company.

"Environmental Report, Operating License Stage -

Salem Nuclear Generating Station Units 1 and 2".

1971.

[6]

Public Service Electric and Gas Company.

"Environmental Report, Operating License Stage -

Hope Creek Generating Station".

1983.

[7]

United States Atomic Energy Commission.

"Final Environmental Statement -

Salem Nuclear Generating Station, Units 1 and 2".

Docket No. 50-272 and 50-311. 1973.

[8]

United States Atomic Energy Commission.

"Final Environmental Statement -

Hope Creek Generating Station, Docket No. 50-354. 1983.

[9]

Public Service Electric and Gas Company.

"Updated Final Safety Analysis Report -

Salem Nuclear Generating Station, Units 1 and 2".

1982.

[10]

Public Service Electric and Gas Company.

"Final Safety Analysis Report -

Hope Creek Generating Station. 1984.

[11]

Public Service Electric and Gas Company.

"Salem Nuclear Generating Station Unit 1 -

Technical Specifications", Appendix A to Operating License No. DPR-70, 1976, Sections 3/4.12 and 6.9.1.10 (Amendment 59 et seq).

[12]

Public Service Electric and Gas Company.

"Salem Nuclear Generating Station Unit 2 -

Technical Specifications", Appendix A to Operating License No. DPR-75, 1981, Sections 3/4.12 and 6.9.1.10 (Amendment 28 et seq)

  • 55

~-------------------------

REFERENCES (cont'd)

[13]

Public Service Electric and Gas Company.

"Hope Creek Generating Station Unit 1 - Technical Specifications", Appendix A to Facility Operating License No. NPF-57, 1986, Sections 3/4.12 and 6.9.1.10.

[14]

Public Service Electric and Gas Company.

"Offsite Dose Calculation Manual" -

Salem Generating Station.

[15]

Public Service Electric and Gas Company.

"Offsite Dose Calculation Manual" -

Hope Creek Generating Station.

[16]

u. s. Environmental Protection Agency.

"Prescribed Procedures for Measurement of Radioactivity in Drinking Water."

EPA-600/4-80-032, August, 1980.

[17]

PSE&G Research and Testing Laboratory.

"Environmental Division Quality Assurance Plan."

November, 1986.

[18]

PSE&G Research and Testing Laboratory.

"Chemical/ Environmental Division Procedures Manual."

February, 1981.

[19]

Public Service Electric and Gas Company.

"Radioactive Effluent Release Reports, SGS RERR-28 and RERR Salem Generating Station. 1990.

[20]

Public Service Electric and Gas Company.

"Radioactive Effluent Release Reports, HCGS RERR-9 and RERR Hope Creek Generating Station. 1990.

[21]

Anthony V. Nero Jr., "A Guidebook to. Nuclear Reactors", University of California Press, 1979.

[22]

Eric J. Hall, "Radiation & Life", Pergamon Press, 1976.

[23]

NCRP Report No. 93, "Ionizing Radiation Exposure of the Population of the United States", 1987.

56

(Jl l.O ARTIFICIAL ISLAND RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM

SUMMARY

SALEM GENERATING STATION HOPE CREEK GENERATING STATION SALEM COUNTY, NEW JERSEY ANALYSIS AND LOWER DOCKET NOS. 50-272/-311 DOCKET NO.

50-354 JANUARY 1, 1990 to DECEMBER 31, 1990 MEDIUM OR PATHWAY TOTAL NUMBER LIMIT OF ALL INDICATOR LOCATIONS LOCATION WITH HIGHEST MEAN SAMPLED OF ANALYSES DETECTION (UNIT OF MEASUREMENT)

PERFORMED (LLD)*

AIRBORNE Air Particulates cio-3 pCi/m3 >

Alpha Beta Sr-89 Sr-90 Gamma Be-7 K-40 318 318 6

6 23 23 1.0 6.0 0.2 0.2 30 8.0 MEAN**

(RANGE) 2.3 (198/265)

(0.8-5.0) 23 (263/265)

(7-48)

<LLD 0.8 (1/5)

(0.8) 63 (18/19)

(50-120)

<LLD NAME

. DISTANCE AND DIRECTION 5S1 1.0 mi E 5S1 1.0 mi E 5D1 3.5 mi E 5D1 3.5 mi E MEAN (RANGE) 2.2 (50/53)

(0.8-5.0) 24 (53/53)

(9-48)

<LLD 0.8 (1/3)

(0.8) 105 (2/3)

(90-120)

<LLD NUMBER OF CONTROL LOCATION NONROUTINE MEAN (RANGE) 2.2 (47/53)

(0.8-4.3) 23 (52/53)

(10-46)

<LLD

<LLD 56 (4/4)

(52-61) 13 (1/4)

(13)

REPORTED MEASUREMENTS 0

0 0

0 0

0 0

ARTIFICIAL ISLAND RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM

SUMMARY

SALEM GENERATING STATION DOCKET NOS. 50-272/-311 HOPE CREEK GENERATING STATION DOCKET NO.

50-354 SALEM COUNTY, NEW JERSEY JANUARY 1, 1990 to DECEMBER 31, 1990 ANALYSIS AND LOWER NUMBER OF MEDIUM OR PATHWAY TOTAL NUMBER LIMIT OF ALL INDICATOR LOCATIONS LOCATION WITH HIGHEST MEAN CONTROL LOCATION NON ROUTINE SAMPLED OF ANALYSES DETECTION MEAN**

NAME MEAN MEAN REPORTED (UNIT OF MEASUREMENT)

PERFORMED (LLD)*

(RANGE)

DISTANCE AND DIRECTION (RANGE)

CRANGE)

MEASUREMENTS AIRBORNE (Cont'd)

Air Iodine I-131 318 30

<LLD

<LLD

<LLD 0

(10-3 pCi/m3)

°'

Precipitation Alpha 12

1. 5
1. 7 (3/12) 2F2 8.7 mi NNE
1. 7 (3/12)

No Control 0

0 (pCi/L)

(1.2-2.1)

(1.2-2.1)

Location Beta 12 2.0***

4.7 (11/12) 2F2 8.7 mi NNE 4.7 (11/12)

No Control 0

(1.4-21)

(1.4-21)

Location H-3 12 150 150 (1/12) 2F2 8.7 mi NNE 150 (1/12)

No Control 0

(150)

(150)

Location Gamma Be-7 12 15 82 (6/12) 2F2 8.7 mi NNE 82 (6/12)

No Control 0

(33-160)

(33-160)

Location 11 DIRECT Direct Radiation Gamma 288 6.0 (252/252) 11S1 0.09 mi SW 8.7 (12/12) 6.0 (36/36) 0 Cmrad/std. month)

Dose (monthly)

(4-12)

(5-12)

(5-8)

Gamma 160 5.0 (137/137) 11S1 0.09 mi SW 7.6 (4/4) 5.0 (23/23) 0 Dose (qtrly.)

(3-10)

(4-10)

(4-6)

ARTIFICIAL ISLAND RADIOLOGICAL ENVIRONMENTAL MONiTORING PROGRAM

SUMMARY

SALEM GENERATING STATION DOCKET NOS. 50-272/-311 HOPE CREEK GENERATING STATION DOCKET NO.

50-354 SALEM COUNTY, NEW JERSEY JANUARY 1, 1990 to DECEMBER 31, 1990 ANALYSIS AND LOWER NUMBER OF MEDIUM OR PATHWAY TOTAL NUMBER LIMIT OF ALL INDICATOR LOCATIONS LOCATION WITH HIGHEST MEAN CONTROL LOCATION NONROUTINE SAMPLED OF ANALYSES DETECTION MEAN**

NAME MEAN MEAN REPORTED (UNIT OF MEASUREMENT)

PERFORMED (LLD)*

(RANGE)

DISTANCE AND DIRECTION (RANGE)

(RANGE)

MEASUREMENTS II I TERRESTRIAL Milk 1-131 80 0.3

<LLD

<LLD

<LLD 0

(pCi/L)

Sr-89 4

1

  • 1

<LLD

<LLD

<LLD 0

O'I Sr-90 4

0.9 2.8 (3/3) 2F7 5.7 mi NNE 4.6 (1/1) 3.0 (1/1) 0 (1.7-4.6)

(4.6)

(3.0)

Gamma K-40 80 120 1400 (60/60) 14F1 5.5 mi WNW 1400 (20/20) 1400 (20/20) 0 (1100-1800)

(1200-1800)

(1200-1800)

Ra-226 80 5.1 20 (1/80) 2F75.7mi NNE 20 (1/80)

<LLD 0

(20)

(20)

Well \\.later Alpha 24

1. 2 0.6 (1/12) 2s3 700 ft NNE 0.6 (1/12) 0.8 (1/12) 0 (pCi/L)

(0.6)

(0.6)

(0.8)

Beta 24 1.0***

4.1 (12/12) 3E1 4.1 mi NE

9. 8 c 12/12) 9.8 (12/12) 0 (2.5-9.9)

(7.7-11)

(7.7-11)

-~ - - -------------~

ARTIFICIAL ISLAND RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM

SUMMARY

SALEM GENERATING STATION DOCKET NOS. 50-272/-311 HOPE CREEK GENERATING STATION DOCKET NO.

50-354 SALEM COUNTY, NEW JERSEY JANUARY 1, 1990 to DECEMBER 31, 1990 ANALYSIS AND LOWER NUMBER OF MEDIUM OR PATHWAY TOTAL NUMBER LIMIT OF ALL INDICATOR LOCATIONS LOCATION WITH HIGHEST MEAN CONTROL LOCATION NON ROUTINE SAMPLED OF ANALYSES DETECTION MEAN**

NAME MEAN MEAN REPORTED (UNIT OF MEASUREMENT)

PERFORMED (LLD)*

(RANGE)

DISTANCE AND DIRECTION (RANGE)

(RANGE)

MEASUREMENTS 111 TERRESTRIAL (Cont'd)

Well Water K-40 24 3.8 (12/12) 3E1 4.1 mi NE 9.6 (12/12) 9.6 (12/12) 0 (pCi/L)

(2.6-7)

(8.1-12)

(8.1-12)

°'

I\\.)

H-3 24 160

<LLD

<LLD

<LLD 0

Sr-89 8

1.0

<LLD

<LLD

<LLD 0

Sr-90 8

0.6

<LLD

<LLD

<LLD 0

Gamma K-40 24 24 53 (1/12) 3E1 4.1 mi NE 71 (4/12) 71 (4/12) 0 (53)

(52-88)

(52-88)

I-131 24 0.8

<LLD

<LLD

<LLD 0

Ra-226 24 3.9 9.0 (4/12) 3E1 4.1 mi NE 136 ( 12/ 12) 136 (12/12) 0 (8-10)

(19-220)

(19-220)

°'

w MEDIUM OR PATHWAY SAMPLED (UNIT OF MEASUREMENT)

ARTIFICIAL ISLAND RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM

SUMMARY

SALEM GENERATING STATION HOPE CREEK GENERATING STATION DOCKET NOS. 50-272/-311 DOCKET NO.

50-354 SALEM COUNTY, NEW JERSEY JANUARY 1, 1990 to DECEMBER 31, 1990 ANALYSIS AND TOTAL NUMBER OF ANALYSES PERFORMED LOWER LIMIT OF DETECTION (LLD)*

ALL INDICATOR LOCATIONS MEAN**

(RANGE)

LOCATION WITH HIGHEST MEAN NAME MEAN DISTANCE AND DIRECTION (RANGE)

Ill TERRESTRIAL (Cont'd)

Potable Water Alpha 24 1.0 1.3 (5/24) 2F3 8.0 mi NNE 1.3 (5/24)

Raw-Treated (1.1-1.7)

(1.1-1.7)

(pCi/L)

Beta 24 1.0***

3.2 (24/24) 2F3 8.0 mi NNE 3.2 (24/24)

(2.2-6.4)

(2.2-6.4)

K-40 24 2.2 (24/24) 2F3 8.0 mi NNE 2.2 (24/24)

(1.4-3.0)

(1.4-3.0)

H-3 24 150 150 (2/24) 2F3 8.0 mi NNE 150 (2/24)

(140-160)

(140-160)

Sr-89 8

1.0

<LLD

<LLD Sr-90 8

0.8

<LLD

<LLD NUMBER OF CONTROL LOCATION NONROUTINE MEAN REPORTED (RANGE)

MEASUREMENTS No Control 0

Location No Control 0

Location No Control 0

Location No Control 0

Location No Control 0

Location No Control 0

Location

ARTIFICIAL ISLAND RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM

SUMMARY

SALEM GENERATING STATION.

DOCKET NOS. 50-272/-311 HOPE CREEK GENERATING STATION DOCKET NO.

50-354 SALEM COUNTY, NEW JERSEY JANUARY 1, 1990 to DECEMBER 31, 1990 ANALYSIS AND LOWER NUMBER OF MEDIUM OR PATHWAY TOTAL NUMBER LIMIT OF ALL INDICATOR LOCATIONS LOCATION WITH HIGHEST MEAN CONTROL LOCATION NONROUTINE SAMPLED OF ANALYSES DETECTION MEAN**

NAME MEAN MEAN REPORTED (UNIT OF MEASUREMENT)

PERFORMED (LLD)*

(RANGE)

DISTANCE AND DIRECTION (RANGE)

CRAN GE)

MEASUREMENTS III TERRESTRIAL (Cont'd)

Potable Water 1-131 24

<0.8

<LLD

<LLD No Control 0

Raw-Treated Location (j\\

Gamma

~

K-40 24 20 54 (1/24) 2F3 8.0 mi NNE 54 (1/24)

No Control 0

(54)

(54)

Location Ra-226 24 3.4 24 (1/24) 2F3 8.0 mi NNE 24 ( 1/24)

No Control 0

(24)

(24)

Location Fruits &

Gamma Vegetables K-40 17 2200 (17/17) 5F3 6.4 mi E 3100 (1/1) 2100 (7/7) 0 (pCi/kg-wet)

(1600-3100)

(3100)

(1800-2500)

Game Gamma (pCi/kg-wet)

K-40 2

2700 ( 1/1) 3E 1 4. 1 mi NE 2700 (1/1)

.2300 (1/1) 0 (2700)

(2700)

(2300)

ARTIFICIAL ISLAND RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM

SUMMARY

SALEM GENERATING STATION DOCKET NOS. 50-272/-311 HOPE CREEK GENERATING STATION DOCKET NO.

50-354 SALEM COUNTY, NEW JERSEY JANUARY 1, 1990 to DECEMBER 31, 1990 ANALYSIS AND LOWER NUMBER OF MEDIUM OR PATHWAY TOTAL NUMBER LIMIT OF ALL INDICATOR LOCATIONS LOCATION WITH HIGHEST MEAN CONTROL LOCATION NONROUTINE SAMPLED OF ANALYSES DETECTION MEAN*"'

NAME MEAN MEAN REPORTED (UNIT OF MEASUREMENT)

PERFORMED (LLD)*

(RANGE)

DISTANCE AND DIRECTION (RANGE)

(RANGE)

MEASUREMENTS I II TERRESTRIAL (Cont'd)

Fodder Crops Gamma CpCi/kg-wet)

Be-7 8

170 530 (4/6) 11F3 5. 3 mi SW 560 (2/2) 600 (1/2) 0 (460-650)

(460-650)

(600)

°'

01 K-40 8

7100 (6/6) 3E1 4.1 mi NE 14000 (1/1) 8600 (2/2) 0 (3000-14000)

(14000)

(3200-1400) 3G1 17 mi NE 8600 (2/2)

(3200-14000)

IV AQUATIC Surf ace Water Alpha 60 2.0

1. 7 (9/48) 11A1 0.2 mi SW 1.9 (3/12) 1.6 (4/12) 0 CpCi/L)

(1.2-2.1)

(1.4-2.1)

(1.0-2.3) 1F2 7.1 mi N 1.7(3/12)

(1.4-2.1)

Beta 60 3.8***

46 (48/48) 7E1 4.5 mi SE 71 (12/12) 38 ( 12/12) 0 (5.4-110)

(43-110)

(15-79)

ARTIFICIAL ISLAND RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM

SUMMARY

SALEM GENERATING STATION DOCKET NOS. 50-272/-311 HOPE CREEK GENERATING STATION DOCKET NO.

50-354 SALEM COUNTY, NEIJ JERSEY JANUARY 1, 1990 to DECEMBER 31, 1990 ANALYSIS AND LOWER NUMBER OF MEDIUM OR PATHIJAY TOTAL NUMBER LIMIT OF ALL INDICATOR LOCATIONS LOCATION IJITH HIGHEST MEAN CONTROL LOCATION NONROUTINE SAMPLED OF ANALYSES DETECTION MEAN**

NAME MEAN MEAN REPORTED (UNIT OF MEASUREMENT)

PERFORMED (LLD)*

(RANGE)

DISTANCE AND DIRECTION (RANGE)

(RANGE)

MEASUREMENTS IV AQUATIC (Cont'd)

Surface Water H-3 20 150 180 (4/16) 11A1 0.2 mi SIJ 190 (2/4) 160 (2/4)

(pCi/L)

(150-230)

(150-230)

( 160) 0 0\\

I-131 60 0.9

<LLD

<LLD

<LLD 0

0\\

Gamma K-40 60 24 86 (33/48) 7E1 4.5 mi SE 103 (11/12) 87 (8/12) 0 (31-170)

(31-170)

(52-140)

Th-232 60 5.0 4.7 (1/48) 16F1 6.9 mi NNIJ 4.7 (1/12)

<LLD 0

(4. 7)

(4. 7)

Blue Crabs Sr-89 4

60

<LLD

<LLD

<LLD 0

(pCi/kg-dry)

(shells)

Sr-90 4

225 (2/2) 12C1 2.5 mi IJSIJ 505 (2/2) 505 (2/2) 0 Cshel ls)

(220-230)

(340-670)

(340-670)

CpCi/kg-wet)

H-3 4

1000 700 (1/2) 11A1 0.2 mi SIJ 700 (1/2)

<LLD 0

(aqueous)

(700)

(700)

Sr-89 4

100 32 (1/2) 11A1 0.2 mi SIJ 32 (1/2)

<LLD 0

(flesh)

(32)

(32)

ARTIFICIAL ISLAND RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM

SUMMARY

SALEM GENERATING STATION DOCKET NOS. 50-272/-311 HOPE CREEK GENERATING STATION DOCKET NO.

50-354 SALEM COUNTY, NEW JERSEY JANUARY 1, 1990 to DECEMBER 31, 1990 ANALYSIS AND LOWER NUMBER OF MEDIUM OR PATHWAY TOTAL NUMBER LIMIT OF ALL INDICATOR LOCATIONS LOCATION WITH HIGHEST MEAN CONTROL LOCATION NONROUTINE SAMPLED OF ANALYSES DETECTION MEAN**

NAME MEAN MEAN REPORTED (UNIT OF MEASUREMENT)

PERFORMED (LLD)*

(RANGE)

DISTANCE AND DIRECTION (RANGE)

(RANGE)

MEASUREMENTS IV AQUATIC (Cont'd)

Blue Crabs Sr-90.

4 40

<LLD

<LLD

<LLD 0

CpCi/kg-wet)

Cflesh)

°'

Gamma

-...J K-40 4

2600 (2/2) 11A1 0.2 mi SW 2600 (2/2) 2400 (2/2) 0 (2300-2800)

(2300-2800)

(2000-2700)

Edible Fish Sr-89 6

75

<LLD

<LLD

<LLD 0

CpCi/kg-dry)

(bones)

Sr-90 6

25 192 (3/4) 12C1 2.5 mi WSW 173 (2/2) 173 (2/2) 0 (bones)

(45-280)

(25-320)

(25-320)

(pCi/kg-wet)

H-3 6

1000

<LLD

<LLD

<LLD 0

(aqueous)

Sr-89 6

100

<LLD

<LLD

<LLD 0

(flesh)

ART! FICIAL ISLAND RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM

SUMMARY

SALEM GENERATING STATION DOCKET NOS. 50-272/-311 HOPE CREEK GENERATING STATION DOCKET NO.

50-354 SALEM COUNTY, NEW JER.SEY JANUARY 1, 1990 to DECEMBER 31, 1990 ANALYSIS AND LOWER NUMBER OF MEDIUM OR PATHWAY TOTAL NUMBER LIMIT OF ALL INDICATOR LOCATIONS LOCATION WITH HIGHEST MEAN CONTROL LOCATION NONROUTIME SAMPLED OF ANALYSES DETECTION MEAN**

NAME MEAN MEAN REPORTED (UNIT OF MEASUREMENT)

PERFORMED (LLD)*

(RANGE)

DISTANCE AND DIRECTION (RANGE)

(RANGE)

MEASUREMEMTS IV AQUATIC (Cont'd)

Edible Fish Sr-90 6

40

<LLD

<LLD

<LLD 0

(pCi/kg-dry)

(flesh)

°'

Gamma 00 K-40 6

3200 (4/4) 7E1 4.5 mi SE 3400 (2/2) 3100 (2/2) 0 (3100-3600)

(3100-3600)

(3000-3100)

Ra-226 6

22 32 (1/4) 11A1 0.2 mi SW 32 (1/4)

<LLD 0

(32)

(32)

Sediment Sr-90 12 25

<LLD

<LLD

<LLD 0

(pCi/kg-dry)

Gamma K-40 12 8600 ( 10/10) 12C1 2.5 mi WSW 17000 (2/2) 17000 (2/2) 0 (2700-16000)

( 17000)

( 17000)

Mn-54 12 21 37 (3/10) 16A1 0. 7 mi NNW 42 (2/2)

<LLD 0

(28-48)

(36-48)

Co-58 12 35 101 (3/10) 11A1 0.2 mi SW 129 ( 2/2)

<LLD 0

(28-230)

(28-230)

°'

\\0 MEDIUM OR PATHWAY SAMPLED (UNIT OF MEASUREMENT)

IV AQUATIC (Cont'd)

Sediment CpCi/kg-dry)

ARTIFICIAL ISLAND RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM

SUMMARY

SALEM GENERATING STATION HOPE CREEK GENERATING STATION SALEM COUNTY, NEW JERSEY LOWER DOCKET NOS. 50-272/-311 DOCKET NO.

50-354 JANUARY 1, 1990 to DECEMBER 31, 1990 ANALYSIS AND TOTAL NUMBER OF ANALYSES LIMIT OF ALL INDICATOR LOCATIONS LOCATION WITH HIGHEST MEAN DETECTION MEAN**

PERFORMED (LLD)*

CRAN GE)

Co-60 12 54 56 (4/10)

(42-87)

Cs-137 12 18 53 (6/10)

(27-74)

Ra-226 12 574 (10/10)

(120-1300)

Th-232 12 650 (10/10)

(120-890)

NAME DISTANCE AND DIRECTION 15A1 0.3 mi NW 7E1 4.5 mi SE 16A1 0. 7 mi NNW 12C1 2.5 mi WSW MEAN (RANGE) 87 (1/2)

(87) 58 (2/2)

(41-74) 835 (2/2)

(370-1300) 965 (2/2)

(940-990)

  • LLD listed is the lower limit of detection which was generally achieved during this reporting period.
    • Mean calculated using values above LLD only.

Fraction of measurements above LLD are in parentheses.

      • Typical LLD value.

CONTROL LOCATION MEAN (RANGE)

<LLD

<LLD 600 (2/2)

(560-640) 965 (2/2)

(940-990)

NUMBER OF NONROUTINE REPORTED MEASUREMENTS 0

0 0

0

APPENDIX B SAMPLE DESIGNATION AND LOCATIONS 71

APPENDIX B SAMPLE DESIGNATION The PSE&G Research And Testing Laboratory identifies samples by a three part code.

The first two letters are the power station identification code, in this case "SA".

The next three letters are for the media sampled.

AIO

=

Air Iodine IDM Immersion Dose (TLD)

APT Air Particulates MLK Milk ECH

=

Hard Shell Blue Crab PWR

=

Potable Water. (Raw)

ESF Edible Fish PWT

=

Potable Water (Treated)

ESS Sediment RWA

=

Rain Water (Precipitation)

FPB Beef SOL

=

Soil FPL Green Leafy Vegetables SWA Surface Water FPV Vegetables (Various)

VGT Fodder Crops (Various)

GAM Game (Muskrat)

WWA

=

Well Water The last four symbols are a location code based on direction and distance from the site.

Of these, the first two represent each of the sixteen angular sectors of 22.5 degrees centered about the reactor site.

Sector one is divided evenly by the north axis and other sectors are numbered in a clock-wise direction; i.e., 2=NNE, 3=NE, 4=ENE, etc.

The next digit is a letter which represents the radial distance from the plant:

s

=

On-site location E

=

4-5 miles off-site A

0-1 miles off-site F

5-10 miles off-site B

1-2 miles off-site G

=

10-20 miles off-site c

2-3 miles off-site H

>20 miles off-site D

3-4 miles off-site The last number is the station numerical designation within each sector and zone; e.g., 1,2,3, *.*

For example, the designation SA-WWA-3El would indicate a sample in the SGS program (SA), consisting of well water (WWA), which had been collected in sector number 3, centered at 45° (north east) with respect to the reactor site at a radial distance of 4 to 5 miles off-site, (therefore, radial distance E).

The number 1 indicates that this is sampling station #1 in that particular sector.

73

SAMPLING LOCATIONS All of the sampling locations and specific information about the individual locations are given in Table B-1.

Maps B-1 and B-2 show the locations of sampling stations with respect to the site.

STATION CODE 2S2 2S3 5Sl 6S2 7Sl lOSl llSl llAl 15Al 16Al 12Cl 4D2 5Dl lODl llDl 14Dl 2El 3El 3E2 TABLE B-1 STATION LOCATION 0.4 mi. NNE of vent 700 ft. NNE of vent; fresh water holding tank 1.0 mi. E of vent; site access road 0.2 mi. ESE of vent; observation building 0.12 mi. SE of vent; station personnel gate 0.14 mi. SSW of vent; site shoreline 0.09 mi. SW of vent; site shoreline 0.2 mi. SW of vent; outfall area 0.3 mi. NW of vent; cooling tower blowdown discharge line outfall 0.7 mi. NNW of vent; south storm drain discharge line 2.5 mi. WSW of vent; west bank of Delaware River 3.7 mi. ENE of vent; Alloway Creek Neck Road 3.5 mi. E of vent; local farm 3.9 mi. SSW of vent; Taylor's Bridge Spur 3.5 mi. SW of vent 3.4 mi. WNW of vent; Bay View, Delaware 4.4 mi. NNE of vent; local farm 4.1 mi. NE of vent; local farm 5.7 mi. NE of vent; local farm 74 SAMPLE TYPES IDM WWA AIO,APT,IDM IDM,SOL IDM IDM IDM ECH,ESF,ESS,SWA ESS ESS ECH,ESF,ESS,SWA IDM,VGT AIO,APT,IDM IDM,SOL GAM IDM IDM FPB,GAM,IDM,VGT WWA FPV

TABLE B-1 (cont'd)

STATION CODE STATION LOCATION SAMPLE TYPES 3E3 5.6 mi. NE of vent; local farm FPV 7El 4.5 mi. SE of vent; 1 mi. W of Mad Horse Creek ESF,ESS,SWA 9El 4.2 mi. s of vent IDM 11E2 5.0 mi. SW of vent IDM 12El 4.4 mi. WSW of vent; Thomas Landing IDM 13El 4.2 mi. W of vent; Diehl House Lab IDM 16El 4.1 mi. NNW of vent; Port Penn AIO,APT,IDM,SOL lFl 5.8 mi. N of vent; Fort Elf sborg AIO,APT,IDM,SOL 1F2 7.1 mi. N of vent; midpoint of Delaware River SWA 2F2 8.7 mi. NNE of vent; Salem Substation AIO,APT,IDM,RWA 2F3 8.0 mi. NNE of vent; Salem Water Company PWR,PWT 2F4 6.3 mi. NNE of vent; local farm FPV,FPL,SOL 2F5 7.4 mi. NNE of vent; Salem High School IDM 2F6 7.3 mi. NNE of vent; Southern Training Center IDM 2F7 5.7 mi. NNE of vent; local farm MLK,VGT,SOL 3F2 5.1 mi. NE of vent; Hancocks Bridge Municipal IDM Building 3F3 8.6 mi. NE of vent; Quinton Township School IDM 5Fl 6.5 mi. E of vent FPV I IDM, SOL 5F3 6.4 mi. E of vent; local farm FPL 6Fl 6.4 mi. ESE of vent; Stow Neck Road IDM 7F2 9.1 mi. SE of vent; Bayside, New Jersey IDM 75

TABLE B-1 (cont'd)

STATION CODE STATION LOCATION SAMPLE TYPES 10F2 5.8 mi. SSW of vent IDM

'llFl 6.2 mi. SW of vent; Taylor's Bridge Delaware IDM 11F3 5.3 mi. SW of vent; Townsend, Delaware MLK,VGT,SOL 12Fl 9.4 mi. WSW of vent; Townsend Elementary School IDM 13F2 6.5 mi. w of vent; Odessa, Delaware IDM 13F3 9.3 mi. w of vent; Redding Middle School,*

IDM Middletown, Delaware 13F4 9.8 mi. W of vent; Middletown, Delaware IDM 14Fl 5.5 mi. WNW of vent; local farm MLK,VGT,SOL 14F2 6.6 mi. WNW of vent; Boyds Corner IDM 14F3 5.4 mi. WNW of vent; local farm FPV 15F3 5.4 mi. NW of vent IDM 16Fl 6.9 mi. NNW of vent; C&D Canal ESS,SWA 16F2 8.1 mi. NNW of vent; Delaware City Public School IDM lGl 10.3 mi. N of vent; local farm FPV 1G3 19 mi. N of vent; Wilmington, Delaware IDM 2Gl 12 mi. NNE of vent; Mannington Township, NJ FPV 3Gl 17 mi. NE of vent; local farm IDM,MLK,VGT,SOL lOGl 12 mi. SSW of vent; Smyrna, Delaware IDM 16Gl 15 mi. NNW of vent; Greater Wilmington Airport IDM 3Hl 32 mi. NE of vent; National Park, New Jersey IDM 3H3 110 mi. NE of vent; Research and Testing AIO,APT,IDM Laboratory 3HS 25 mi. NE of vent; local farm FPL,FPV

  • 76

15 3

MAP B-i ON-SITE SAMPLING LOCATIONS ARTIFICIAL ISLAND 1

9 77 5

N

/

H*b I IC&U MAP B-2 OFF-SITE SAMPLING LOCATIONS ARTIFICIAL ISLAND

\\

\\

\\

\\

\\

\\

\\

78

\\

\\

\\

\\ \\

\\

\\

\\

\\

APPENDIX C DATA TABIES 79

APPENDIX C DATA TABLES Appendix C presents the analytical results of the 1990 Artificial Island Radiological Environmental Monitoring Program for the period of January 1 to December 31, 1990.

TABLE NO.

C-1 C-2 c-3 c-4 c-s C-6 C-7 C-8 TABLE OF CONTENTS TABLE DESCRIPTION PAGE ATMOSPHERIC ENVIRONMENT AIR PARTICULATES 1990 Concentrations of Gross Alpha Emitters ******************.*

84 1990 Concentrations of Gross Beta Emitters *********************

86 1990 Concentrations of Strontium-89 and Strontium-90 and Gamma Emitters in Quarterly Composites ********************

88 AIR IODINE 1990 Concentrations of Iodine-131 ******************************

89 DATES 1990 Sampling Dates for Air Samples ****************************

91 PRECIPITATION 1990 Concentrations of Gross Alpha and Gross Beta Emitters and Tritium and Gamma Emitters ***********************.**.*****.

96 DIRECT RADIATION THERMOLUMINESCENT DOSIMETERS 1990 Quarterly TLD Results ******************..********..****.**

97 1990 Monthly TLD Results.********...***.***...**..*****.****...

98 81

~~~------------------

TABLE NO.

C-9 C-10 C-11 c-12 C-13 C-14 C-15 C-16 C-17 C-18 C-19 DATA TABLES (cont'd.)

TABLE DESCRIPTION TERRESTRIAL ENVIRONMENT MILK 1990 Concentrations of Iodine-131 and Gamma Emitters *******.***

1990 Concentrations of Strontium-89 and Strontium-90 *.*********

WELL WATER 1990 Concentrations of Gross Alpha and Gross Beta Emitters; Potassium-40 and Tri ti um **********************************

1990 Concentrations of Iodine 131 and Gamma Emitters ***********

1990 Concentrations of Strontium-89 and Strontium-90 in Quarterly Composites......................................

POTABLE WATER 1990 Concentrations of Gross Alpha and Gross Beta Emitters; Potassiurn-40 and Tritium..................................

1990 Concentrations of Iodine 131 and Gamma Emitters ***********

1990 Concentrations of Strontium-89 and Strontium-90 in Quarterly Composites......................................

FOOD PRODUCTS 1990 Concentrations of Gamma Emitters in Vegetables ************

1990 Concentrations of Gamma Emitters in Beef and Game *********

FODDER CROPS 1990 Concentrations of Gamma Emitters **************************

82 PAGE 100 102 103 104 105

  • 106 107 108 109 110 111

TABLE NO.

C-20 C-21 C-22 C-23 C-24 C-25 C-26 C-27 DATA TABLES (cont'd.)

TABLE DESCRIPTION PAGE AQUATIC ENVIRONMENT SURFACE WATER 1990 Concentrations of Gross Alpha Emitters ********************

112 1990 Concentrations of Gross Beta Emitters ********************.

113 1990 Concentrations of Iodine 131 and Gamma Emitters ***********

114 1990 Concentrations of Tritium in Quarterly Composites *********

116 EDIBLE FISH 1990 Concentrations of Strontium-89 and Strontium-90 and Tritium and Gamma Emitters *******************.******.*...*

117 BLUE CRABS 1990 Concentrations of Strontium-89 and Strontium-90 and Tritium and Gamma Emitters *******************************

118 SEDIMENT 1990 Concentrations of Strontium-90 and Gamma Emitters *******.*

119 SPECIAL TABLES LLDs 1990 PSE&G Research and Testing Laboratory LLDs for Gamma Spectrometry. * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *.. * *

  • 12 O 83

TABLE C-1 1990 CONCENTRATIONS OF GROSS ALPHA EMITTERS IN AIR PARTICULATES Results in Units of 10- 3 pCi/m3 +/- 2 sigma

<--------------------------------- STATION ID --------------------------------->

MONTH SA-APT-5Sl SA-APT-501 SA-APT-16El SA-APT-lFl SA-APT-2F2 SA-APT-3H3 AVERAGE (Control)

JANUARY 3.6+/-0.9

<5.0 3.2+/-1.0 3.9+/-1.0 3.6+/-1.0 3.1+/-0. 9 3.5+/-0.6

<1.1

<5.0 2.2+/-0.9 2.2+/-1.0 2.1+/-1.1 2.4+/-1.1 2.0+/-0.9

1. 8+/-0. 7

<5.0

1. 5+/-0. 8 1.8+/-0.8 1.9+/-0.8 1.5+/-0.7 1.7+/-0.3 2.4+/-0.9

<5.0 2.5+/-0.9 2.7+/-0.9 2.5+/-0.9

2. 8+/-1.0 2.6+/-0.3
1. 9+/-0. 8 0<5. 0 1.2+/-0.7
1. 4+/-0. 7 2.5+/-0.8 2.3+/-0.9
1. 9+/-1. 0 FEBRUARY

<1.1

<5.0

<1.3

<1.1

<9.8 (1)

1. 4+/-0. 8
1. 9+/-0. 8

<5.0 2.0+/-0.9 2.0+/-0.8 2.2+/-0.7 2.6+/-0.8 2.1+/-0.5 3.0+/-0.9

<5.0 2.6+/-0.9 2.5+/-1.1 ( 2) 2.8+/-0.9 2.1+/-0.8 2.6+/-0.6

1. 9+/-0. 8

<5.0 1.7+/-0.8

<2.7

( 1) 2.4+/-0.9 2.5+/-0.9 2.1+/-0.7 MARCH 2.1+/-0.7

<5.0 2.4+/-0.8 2.0+/-0.8 2.2+/-0.7 2.3+/-0.7 2.2+/-0.3 2.8+/-0.8

<5.0 2.3+/-0.9 3.0+/-0.9 2.8+/-0.9 2.5+/-0.9 2.7+/-0.5 00 2.0+/-0.8.

<5.0 1.8+/-0.8 1.7+/-0.7 2.4+/-0.8

1. 6+/-0. 7
1. 9+/-0. 6

~

2.4+/-0.8

<5.0

1. 8+/-0. 7 2.1+/-0. 8 2.1+/-0.8 2.5+/-0.8 2.2+/-0.5 APRIL
1. 2+/-0. 7

<5.0

1. 0+/-0. 6 1.5+/-0.7 1.3+/-0.7
1. 6+/-0. 7 1.3+/-0.4
1. 7+/-0. 7

<5.0

1. 0+/-0. 7 2.1+/-0. 8
1. 8+/-0. 7
1. 9+/-0. 8 1.7+/-0.8

<1.1

<5.0

<1.1

<1.1

<1.1

1. 5+/-0. 8 2.5+/-0.8

<5.0 2.2+/-0.8 2.8+/-0.9 2.9+/-0.8 3.1+/-0.9 2.7+/-0.6 2.3+/-0.8

<5.0 2.1+/-0.7 2.4+/-0,8 3.0+/-0.8 2.5+/-0.8 2.5+/-0.6 MAY 2.8+/-0.8

<5.0 3.3+/-0.9 3.1+/-0.9 2.2+/-0.7

1. 7+/-0. 7 2.6+/-1.2 1.9+/-0.9

<5.0

2. 5+/-1.0
1. 6+/-0. 8 1.6+/-0.8 2.0+/-0.8 1.9+/-0. 7
1. 4+/-0. 8

<5.0

1. 2+/-0. 7 2.4+/-0.9 1.9+/-0.8

<1.0

1. 6+/-1. 0 0.8+/-0.6

<5.0 0.8+/-0.6

<0.7 0.8+/-0.6 0.8+/-0.5 0.8+/-0.1 JUNE 1.6+/-0.8

<5.0 1.1+/-0. 8

1. 9+/-0. 9
1. 7+/-0. 7
1. 6+/-0. 9
1. 6+/-0. 5
1. 7+/-0. 6

<5.0

1. 7+/-0. 7
1. 9+/-0. 7 1.5+/-0.6
1. 0+/-0. 5 1.6+/-0. 6
1. 5+/-0. 7

<5.0 1.3+/-0.8

1. 2+/-0. 8
1. 0+/-0. 7

<0.9 1.2+/-0.4 2.1+/-0. 9

<5.0

4. 7+/-1. 2 3.9+/-1.2 2.5+/-1.0
1. 2+/-0. 7 2.9+/-2.6

00 U1 TABLE c--nt'd) 1990 CONCENTRATIONS OF GROSS ALPHA EMITTERS IN AIR PARTICULATES Results in Units of 10-3 pCi/m3 +/- 2 sigma

<--------------------------------- STATION ID --------------------------------->

MONTH JULY AUGUST SEPTEMBER OCTOBER NOVEMBER DECEMBER AVERAGE SA-APT-5Sl

1. 3+/-0. 7 1.0+/-0.7 1.9+/-0.7 2.4+/-0.8 1.4+/-0.7
1. 8+/-0. 8 2.0+/-0.7 1.4+/-0.6 2.7+/-0.9
2. 6+/-1. 0
2. 5+/-1. 0 2.1+/-0.8
1. 7+/-0. 7 3.0+/-1.l 1.8+/-0.8 3.4+/-1.l 2.3+/-0.8 2.5+/-0.9 5.0+/-1.2 2.8+/-0.8 4.5+/-1.2
1. 9+/-0. 9 3.4+/-0.9 2.4+/-0.8
1. 5+/-0. 8 1.1+/-0. 7 2.2+/-0.8 2.1+/-1.7 SA-APT-5Dl SA-APT-16El

<5.0

1. 5+/-0. 8

<5.0

<0.8

<5.0 2.0+/-0.8

<5.0 2.2+/-0.9

<5.0

1. 4+/-0. 7

<5.0

1. 9+/-0. 8

<5.0

1. 7+/-0.8

<5.0

1. 9+/-0. 7

<5.0 2.3+/-0.8

<5.0 2.2+/-1.0

<5.0 1.8+/-1.0

<5.0 2.9+/-0.9

<5.0

<0.9

<5.0 2.8+/-1.0

<5.0 1.5+/-0.7

<5.0

1. 5+/-0. 8

<5.0 2.4+/-0.8

<5.0 3.8+/-1.0

<5.0

4. 3+/-1.2

<5.0 3.4+/-0.9

<5.0 2.4+/-1.0

<5.0 2.2+/-0.8

<5.0 4.5+/-1.1

<5.0 3.0+/-0.9

<5.0 1.7+/-0.8

<5.0 1.0+/-0.8

<5.0 2.2+/-0.8 2.1+/-1.8 SA-APT-lFl SA-APT-2F2 SA-APT-3H3 (Control) 2.8+/-1.0

1. 4+/-0. 7
1. 3+/-0. 7 1.6+/-0.8
1. 2+/-0. 7 1.1+/-0. 6 2.4+/-0.8
1. 6+/-0. 7 1.4+/-0. 7
1. 6+/-0. 7 2.1+/-0.8 2.3+/-0.8 2.0+/-0.8
1. 5+/-0. 7 0.8+/-0.6 1.9+/-0.8 2.6+/-0.9 2.3+/-0.7
1. 6+/-0. 7 2.5+/-0.8
1. 5+/-0. 8 1.7+/-0.7 1.2+/-0.6 2.7+/-0.8 2.9+/-0.9 2.8+/-0.9

<0.7 2.4+/-0.9 2.7+/-1.0 1.9+/-0~7

1. 8+/-1. 0
1. 5+/-0. 9
2. 6+/-1. 0 2.2+/-0.8 2.1+/-0.8 2.3+/-0.8
1. 6+/-0. 7
1. 4+/-0. 7 1.3+/-0.7 1.5+/-0.8 3.2+/-1.0 2.4+/-0.8 2.0+/-0.8 1.8+/-0. 7 2.0+/-0.9 ( 2) 2.8+/-1.0 3.2+/-1.0 3.0+/-1.1 2.7+/-0.9 2.5+/-0.8 2.0+/-0.8 2.0+/-0.8 2.5+/-1.2 (2)
1. 8+/-0. 8
3. 8+/-1. l 4.8+/-1.2
4. 3+/-1.1 3.0+/-0.8 3.3+/-0.9 2.5+/-0.7 3.8+/-1.2 3.8+/-1. 2
3. 5+/-1.1 2.8+/-1.0 2.8+/-1.0 2.0+/-0.8 3.8+/-0.9 3.8+/-0.9 3.6+/-0.9 3.1+/-0.9 3.6+/-0.9
2. 3+/-1.0 (3)
1. 2+/-0. 8

<1.1 1.9+/-0.9 1.5+/-0.9 2.0+/-1.0 3.0+/-1.0 2.6+/-0.9 2.2+/-0.8 2.0+/-0.8 2.2+/-1.6 2.3+/-1.7 2.1+/-1.5 GRAND AVERAGE

  • Sampling dates can be found in Table C-5.
    • Results by Controls for Environmental Pollution, Inc.

(1) High LLD due to low sample volume.(Result not included in any averages)

(2) Reduced samplin~ period due to air sampler malfunction.

(3) Shorter collection period for air filter due to component separation on sampler inlet to air iodine filter.

(Result not included in any averages)

AVERAGE

1. 7+/-1. 2 1.1+/-0. 5 1.9+/-0.7 2.1+/-0. 6 1.4+/-0.8 2.1+/-0.6
1. 9+/-0. 7
1. 8+/-1.1
2. 3+/-1. 7 2.4+/-0.6 2.0+/-0.9 2.3+/-0.6
1. 4+/-0. 6
2. 6+/-1. 2 1.8+/-0.4 2.8+/-1.4 2.4+/-0.5
2. 5+/-1. 4 4.4+/-0.9 3.0+/-0.7
3. 6+/-1. 4 2.3+/-0.8 3.8+/-0.8 3.0+/-0.9
1. 5+/-0. 6
1. 7+/-1. 5 2.2+/-0.4 2.2+/-1.7

TABLE C-2 1990 CONCENTRATIONS OF GROSS BETA EMITTERS IN AIR PARTICULATES Results in Units of 10*3 pCi/m3 +/- 2 sigma

<--------------------------------- STATION ID --------------------------------->

MONTH SA-APT-5Sl SA-APT-501 SA-APT-16El SA-APT-lFl SA-APT-2F2 SA-APT-3H3 AVERAGE (Control)

JANUARY 32+/-3 26+/-2 30+/-3 29+/-3 32+/-3 29+/-3 30+/-4 30+/-3 31+/-2 35+/-3 34+/-3 34+/-4 34+/-4 33+/-4 24+/-3 23+/-2 21+/-3 20+/-3 26+/-3 28+/-3 24+/-6 25+/-3 19+/-2 23+/-3 26+/-3 25+/-3 26+/-3 24+/-5 26+/-3 26+/-2 20+/-2 24+/-3 28+/-3 25+/-3 25+/-5 FEBRUARY 15+/-2 18+/-2 17+/-3 16+/-2

<25 ( 1) 15+/-2 16+/-2 22+/-3 22+/-2 23+/-3 21+/-2 22+/-2 26+/-2 23+/-3 24+/-3 25+/-2 26+/-3 25+/-3 (2) 26+/-3 23+/-2 25+/-2 23+/-2 20+/-2 21+/-2 27+/-6 ( 1) 20+/-2 20+/-2 21+/-2 MARCH 29+/-3 27+/-2 28+/-3 26+/-3 28+/-3 29+/-3 28+/-2 28+/-3 20+/-2 27+/-3 28+/-3 28+/-3 26+/-3 26+/-6 00 16+/-2 25+/-2 14+/-2 15+/-2 14+/-2 14+/-2 16+/-8

°'

24+/-2 20+/-2 24+/-3 24+/-3 24+/-3 23+/-3 23+/-3 APRIL 14+/-2 9.0+/-2.0 13+/-2 12+/-2 13+/-2 15+/-2 13+/-4 15+/-2 12+/-2 16+/-2 15+/-2 16+/-2 15+/-2 15+/-3 21+/-3 20+/-2 17+/-2 18+/-2 20+/-2 22+/-2 20+/-3 26+/-3 23+/-2 26+/-3 24+/-3 28+/-3 34+/-3 27+/-7 28+/-3 26+/-2 26+/-3 32+/-3 28+/-3 26+/-3 28+/-4 MAY 22+/-2 16+/-2 25+/-3 21+/-3 23+/-2 16+/-2 20+/-7 20+/-3 16+/-2 20+/-3 23+/-3 22+/-2 21+/-2 20+/-4 19+/-2.

20+/-2 19+/-2 19+/-3 18+/-2 11+/-2 18+/-6 9.0+/-2.0 7.0+/-1.0 9.7+/-2.0 10+/-2

8. 5+/-1. 9 10+/-2 9.0+/-2.0 JUNE 17+/-2 12+/-2 15+/-2 17+/-2 13+/-2 16+/-2 15+/-4 17+/-3 20+/-2 13+/-2 16+/-2 16+/-2 13+/-2 16+/-5 16+/-2 9.0+/-2.0 14+/-2 15+/-3 15+/-2 10+/-2 13+/-5 18+/-3 14+/-2 22+/-3 22+/-3 21+/-3 18+/-2 19+/-6

00

'1 TABLE 1990 CONCENTRATIONS OF GROSS BETA EMITTERS IN AIR PARTICULATES Results in Units of 10*3 pCi/m3 +/- 2 sigma

<--------------------------------- STATION ID --------------------------------->

MONTH SA-APT-5Sl SA-APT-5Dl SA-APT-16El SA-APT-lFl SA-APT-2F2 SA-APT-3H3 (Control)

JULY 28+/-3 23+/-2 27+/-3 32+/-3 27+/-3 19+/-3 21+/-2 18+/-2 18+/-2 19+/-2 18+/-2 19+/-2 17+/-2 15+/-2 17+/-2 18+/-2 15+/-2 13+/-2 25+/-3 19+/-2 26+/-3 25+/-3 24+/-3 31+/-3 13+/-2 11+/-1 12+/-2 16+/-2 14+/-2 12+/-2 AUGUST 18+/-3 18+/-2 16+/-3 19+/-3 17+/-3 17+/-2 27+/-2 23+/-2 25+/-2 24+/-2 25+/-2 20+/-2 21+/-3 19+/-2 23+/-3 21+/-2 22+/-3 33+/-3 19+/-2 25+/-2 20+/-2 19+/-2 17+/-2 13+/-2 SEPTEMBER 30+/-3 28+/-2 26+/-3 29+/-3 31+/-3 26+/-2 27+/-3 27+/-2 22+/-3 24+/-3 23+/-3 20+/-3 26+/-3 24+/-2 28+/-3 26+/-3 27+/-3 33+/-3 20+/-2 18+/-2 20+/-3 19+/-2 19+/-2 15+/-2 28+/-3 28+/-2 31+/-3 30+/-3 33+/-3 28+/-2 OCTOBER 29+/-3 20+/-2 24+/-2 26+/-3 26+/-2 24+/-3 ( 2) 17+/-3 18+/-2 18+/-3 17+/-3 18+/-3 18+/-3 28+/-3 26+/-2 26+/-3 24+/-3 25+/-2 27+/-3 24+/-3 18+/-2 24+/-2 24+/-2 27+/-3 (2) 24+/-2 NOVEMBER 48+/-3 43+/-2 47+/-4 42+/-3 46+/-3 46+/-3 26+/-2 21+/-2 24+/-2 24+/-2 24+/-2 20+/-2 35+/-3 37+/-2 32+/-3 36+/-3 33+/-3 32+/-3 33+/-3 30+/-2 36+/-3 35+/-3 35+/-3 36+/-3 DECEMBER 34+/-3 28+/-2 34+/-3 34+/-3 36+/-3 30+/-3 28+/-3 33+/-2 26+/-3 29+/-3 28+/-3 29+/-4 (3) 26+/-3 24+/-2 27+/-3 22+/-3 26+/-3 28+/-3 14+/-2 17+/-2 17+/-2 21+/-3 19+/-3 20+/-2 26+/-3 26+/-2 27+/-3 30+/-3 26+/-3 28+/-3 AVERAGE 24+/-14 22+/-14 23+/-14 23+/-13 24+/-14 23+/-16 GRAND AVERAGE

  • Sampling dates can be found in Table C-5.
    • Results by Controls for Environmental Pollution, Inc.

AVERAGE 26+/-8 19+/-2 16+/-3 25+/-7 13+/-3 18+/-2 24+/-4 23+/-9 19+/-7 28+/-4 24+/-5 27+/-6 18+/-4 30+/-4 25+/-6 18+/-1 26+/-3 24+/-6 45+/-4 23+/-4 34+/-4 34+/-4 33+/-6 29+/-4 26+/-4 18+/-5 27+/-3 23+/-14 (1) High LLD due to low sample volume (air sampler malfunction).

Result not included in any averages.

(2) Reduced sampling period due to air sampler malfunction.

(3) Shorter collection period for air filter due to component iodine filter.

(Result not included in any averages) separation on sampler inlet to air

TABLE C-3 1990 CONCENTRATIONS OF STRONTIUM-89* AND STRONTIUM-90 AND GAMMA EMITTERS**

IN QUARTERLY COMPOSITES OF AIR PARTICULATES Results in Units of 10-3 pCi/m3 +/- 2 sigma *

<-- STRONTIUM -->

<-- GAMMA EMITTERS -->

STATION ID SAMPLING PERIOD Sr-89 Sr-90 Be-7 SA-APT-5S1 12-26-89 to 03-26-90

<0.4

<0.2 60+/-5 SA-APT-5D1 (1) 12*26-89 to 03-26-90

<1.0 0.8+/-0.4

<LLD SA-APT-16E1 12-26*89 to 03-26-90

<0.4

<0.2 62+/-5 SA-APT-1F1 12-26*89 to 03-26-90

<0.4

<0.2 54+/-5 SA-APT-2F2 12-26-89 to 03-26-90

<0.3

<0.2 56+/-5 SA-APT-3H3 (C) 12-26-89 to 03-26-90

<0.3

<0.2 61+/-5 SA-APT-5S1 03-26-90 to 06-26-90 62+/-6 SA-APT-5D1 ( 1) 03-26-90 to 06-26-90 (2)

SA-APT-16E1 03-26-90 to 06-26-90 56+/-5 SA-APT-1F1 03-26*90 to 06-26-90 61+/-6 SA-APT-2F2 03-26-90 to 06-26-90 58+/-6 SA-APT-3H3 (C) 03-26-90 to 06-26-90 58:!:5 SA-APT-5S1 06-26*90 to 10-01-90 57+/-4 SA-APT-5D1 (1) 06-26*90 to 10-01-90 120+/-32 SA-APT-16E1 06-26*90 to 10-01-90 59+/-5 SA-APT-1F1 06-26-90 to 10-01-90 55+/-4 SA-APT-2F2 06-26-90 to 10-01-90 52+/-4 SA-APT-3H3 (C) 06-25*90 to 10-01-90 52:!:4 SA-APT-5S1 10-01-90 to 12-31-90 50+/-4 SA-APT-5D1 (1) 10*01-90 to 12-31-90 90+/-50 SA*APT-16E1 10-01-90 to 12-31-90 58+/-5 SA-APT-1F1 10-01*90 to 12-31-90 59+/-5.

SA-APT-2F2 10-01-90 to 12-31-90 56+/-5 SA-APT-3H3 (C) 10*01-90 to 12-31-90 53+/-5 AVERAGE 61+/-30

  • Sr-90 results are corrected for decay to sample stop date.
    • All other gamma emitters searched for were <LLD; typical LLDs are given in Table C-27.
      • Management audit analyses, not required by Technical Specifications or by specific commitments to local officials.

(C) Control Station (1) Results by Controls for Environmental Pollution, Inc.

Undetected gamma emitters are reported as <LLD.

(2) Results not reported by C.E.P.

88 K-40

<5.3

<LLD

<4.7

<5.6

<4.7

<8.4

<4.3 (2)

<4.7

<14

<5.1

<4.5

<4.5

<LLD

<5.5

<4.6

<4.8

<4.8

<4.0

<130

<4.5

<4.5

<5.1 13+/-4

~----------------------------~~

TABLE C-4 1990 CONCENTRATIONS OF IODINE-131* IN FILTERED AIR Results in Units of 10-3 pCi/m3

<-------------------------------------- STATION ID -------------------------------------->

MONTH SA-AI0-5Sl SA-AI0-501 SA-AI0-16El SA-AIO-lFl SA-AI0-2F2 SA-AI0-3H3 (Control)

JANUARY

<7.0

<13

<8.9

<13

<4.0

<8.6

<16

<13

<17

<16

<8.8

<8.2

<4.7

<13

<11

<14

<7.2

<10

<4.4

<13

<16

<11

<15

<7.0

<7.7

<13

<12

<12

<7.6

<12 FEBRUARY

<12

<13

<14

<14

<13

<7.5

<4.6

<13

<13

<8.0

<8.0

<3.6

<13

<13

<13

<12 ( 1)

<4.1

<4.7

<15

<13

<9.5

<24 ( 1)

<5.1

<13 00

<4.7

<13

<14

<10

<8.4

<11

~

MARCH

<13

<13

<13

<12

<4.5

<8.5

<7.4

<13

<14

<8.0

<13

<5.2

<9.8

<13

<6.0

<8.8

<7.0

<7.5

<13

<13

<10

<14

<12

<4.1 APRIL

<6.2

<13

<6.4

<7.5

<5.9

<8.4

<6. 7

<13

<14

<5.1

<7.2

<5.2

<5.6

<13

<10

<6.3

<8.6

<5.7

<6.5

<13

<8.4

<11

<6.3

<4.3 MAY

<7.9

<13

<6.7

<6.7

<4.6

<4.6

<12

<13

<8.8

<7.9

<3.9

<5.0

<5.9

<13

<4.4

<9.4

<5.4

<10

<13

<13

<12

<6.3

<12

<6.5 JUNE

<13

<13

<14

<6.0

<5.0

<6.2

<12

<13

<9.8

<6.0

<5.7

<8.7

<9.4

<13

<13

<6.5

<7.4

<7.7

<14

<13

<13

<9.1

<12

<5.2

TABLE C-4 (Cont'd) 1990 CONCENTRATIONS OF IODINE-131* IN Results in Units of 10-3

<-------------------------------------- STATION MONTH SA-AI0-551 SA-AI0-501 SA-AI0-16El JULY

<8.5

<13

<6.9

<6.8

<13

<11

<11

<13

<12

<11

<13

<6.2

<6.0

<13

<7.1 AUGUST

<5.8

<13

<12

<7.7

<13

<5.4

<8.5

<13

<4.6

<9.8

<13

<7.4

\\0 o

SEPTEMBER

<3.6

<13

<7.3

<5.4

<13

<11

<3.9

<13

<4.8

<8.2

<13

<11

<6.6

<13

<4.7 OCTOBER

<4.7

<13

<6.4

<7.8

<13

<6.2

<4.6

<13

<5.3

<8.0

<13

<10 NOVEMBER

<5.2

<13

<7.2

<8.0

<13

<4.2

<7.4

<13

<5.6

<13

<13

<5.2 DECEMBER

<6.1

<13

<7.1

<5.5

<13

<6.3

<5.7

<13

<5.1

<6.0

<13

<6.7

<5.1

<13

<7.3

  • I-131 results are corrected for decay to sample stop date.
    • Sampling dates can be found in Table C-5.

sults by Controls for Environmental Pollution, Inc.

uced sampling period due to air sampler malfunc~

(1 FILTERED AIR pCi/m3 ID -------------------------------------->

SA-AIO-lFl SA-AI0-2F2 SA-AI0-3H3 (Control)

<5.5

<8.4

<8.0

<11

<9.8

<4.6

<5.3

<8.6

<8.7

<8.8

<7.9

<7.8

<7.0

<7.1

<5.1

<11

<9.6

<10

<5.2

<4.5

<4.1

<6.1

<14

<12

<5.4

<7.1

<6.7

<12

<8.5

<4.2

<6.6

<12

<5.4

<12

<13

<6.6

<10

<3.9

<8.9

<8.5

<3.8

<6.4

<6.8

<4.6

<5.7 ( 1)

<3.5

<5.9

<11

<8.7

<6.0

<6.9

<4.1

<18 ( 1)

<5.9

<4.9

<9.1

<6.8

<5.7

<4.5

<7.8

<6.7

<10

<9.9

<7.1

<11

<4.2

<3.9

<5.5

<6.0

<11

<4.3

<4.4

<5.4

<19

<6.4

<17

<8.0

<3.8

<14

<8.5

<5.3

TABLE C-5 1990 SAMPLING DATES FOR AIR SAMPLES

<------------------------------------ STATION CODE ------------------------------~----->

MONTH 5Sl 5Dl 16El lFl 2F2 3H3 (Control)

JANUARY 12-26-89 12-26-89 12-26-89 12-26-89 12-26-89 12-26-89 to to to to to to 01-02-90 01-02-90 01-02-90 01-02-90 01-02-90 01-02-90 01-02-90 01-02-90 01-02-90 01-02-90 01-02-90 01-02-90 to to to to to to 01-08-90 01-08-90 01-09-90 01-08-90 01-08-90 01-08-90 01-08-90 01-08-90 01-09-90 01-08-90 01-08-90 01-08-90 to to to to to to 01-15-90 01-15-90 01-15-90 Ol-15-90 01-15-90 01-15-90 01-15-90 01-15-90 01-15-90 01-15-90 01-15-90 01-15-90 to to to to to to 01-22-90 01-22-90 01-22-90 01-22-90 01-22-90 01-22-90 I.()

01-22-90 01-22-90 01-22-90 01-22-90 01-22-90 01-22-90 to to to to to to 01-29-90 01-29-90 01-30-90 01-29-90 01-29-90 01-29-90 FEBRUARY 01-29-90 01-29-90 01-30-90 01-29-90 01-29-90 01-29-90 to to to to to to 02-05-90 02-05-90 02-05-90 02-05-90 02-05-90 02-05-90 02-05-90 02-05-90 02-05-90 02-05-90 02-05-90 02-05-90 to to to to to to 02-13-90 02-13-90 02-13-90 02-13-90 02-13-90 02-13-90 02-13-90 02-13-90 02-13-90 02-13-90 02-13-90 02-13-90 to to to to to to 02-20-90 02-20-90 02-20-90 02-19-90 ( 1) 02-20-90 02-20-90 02-20-90 02-20-90 02-20-90 02-20-90 02-20-90 02-20-90

/

to to to to to to 02-26-90 02-26-90 02-27-90 02-22-90 (1) 02-26-90 02-26-90

-MARCH 02-26-90 02-26-90 02-27-90 02-26-90 02-26-90 02-26-90 to to to to to to 03-05-90 03-05-90 03-05-90 03-05-90 03-05-90 03-05-90 03-05-90 03-05-90 03-05-90 03-05-90 03-05-90 03-05-90 to to to to to to 03-12-90 03-12-90 03-12-90 03-12-90 03-12-90 03-12-90

TABLE C-5 (Cont'd) 1990 SAMPLING DATES FOR AIR SAMPLES

<------------------------------------ STATION CODE ------------------------------------>

MONTH 5Sl 5Dl 16El lFl 2F2 3H3 (Control)

MARCH 03-12-90 03-12-90 03-12-90 03-12-90 03-12-90 03-12-90 to to to to to to 03-19-90 03-19-90 03-19-90 03-19-90 03-19-90 03-19-90 03-19-90 03-19-90 03-19-90 03-19-90 03-19-90 03-19-90 to to to to to to 03-26-90 03-26-90 03-26-90 03-26-90 03-26-90 03-26-90 APRIL 03-26-90 03-26-90 03-26-90 03-26-90 03-26-90 03-26-90 to to to to to to 04-02-90 04-02-90 04-02-90 04-02-90 04-02-90 04-02-90 04-02-90 04-02-90 04-02-90 04-02-90 04-02-90 04-02-90 to to to to to to 04-09-90 04-09-90 04-09-90 04-09-90 04-09-90 04-09-90 U) t\\)

04-09-90 04-09-90 04-09-90 04-09-90 04-09-90

.04-09-90 to to to to to to 04-16-90 04-16-90 04... 16-90 04-16-90 04-16-90 04-16-90 04-16-90 04-16-90 04-16-90 04-16-90 04-16-90 04-16-90 to to to to to to 04-23-90 04-23-90 04-23-90 04-23-90 04-23-90 04-23-90 04-23-90 04-23-90 04-23-90 04-23-90 04....:23-90 04-23-90 to to to to to to 04-30-90 04-30-90 04-30-90 04-30-90 04-30-90 04-30-90 MAY 04-30-90 04-30-90 04-30-90 04-30-90 04-30-90 04-30-90 to to to to to to 05-07-90 05-07-90 05-07-90 05-07-90 05-07-90 05-07-90 05-07-90 05-07-90 05-07-90 05-07-90 05-07-90 05-07-90 to to to to to to 05-14-90 05-14-90 05-14-90 05-14-90 05-14-90 05-14-90 05-14-90 05-14-90 05-14-90 05-14-90 05-14-90 05-14-90 to to to to to to 05-21-90 05-21-90 05-21-90 05-21-90 05-21-90 05-21-90 05-21-90 05-21-90 05-21-90 05-21-90 05-21-90 05-21-90 to to to to to to 05-29-90 05-29-90 05-29-90 05-29-90 05-29-90 05-29-90

TABLE C-5 (Cont'd) 1990 SAMPLING DATES FOR AIR ~AMPLES

<------------------------------------ STATION CODE ------------------------------------>

MONTH 5Sl 5Dl 16El lFl 2F2 3H3 (Control)

JUNE 05-29-90 05-29-90 05-29-90 05-29-90 05-29-90 05-29-90 to to to to to to 06-05-90 06-05-90 06-05-90 06-05-90 06-05-90 06-04-90 06-05-90 06-05-90 06-05-90 06-05-90 06-05-90 06-04-90 to to to to to to 06-12-90 06-12-90 06-12-90 06-12-90 06-12-90 06-11-90 06-12-90 06-12-90 06-12-90 06-12-90 06-12-90 06-11-90 to to to to to to 06-19-90 06-19-90 06-19-90 06-19-90 06-19-90 06-18-90 06-19-90 06-19-90 06-19-90 06-19-90 06-19-90 06-18-90 to to to to to to 06-26-90 06-26-90 06-26-90 06-26-90 06-26-90 06-25-90

\\0 w

JULY 06-26-90 06-26-90 06-26-90 06-26-90 06-26-90 06-25-90 to to to to to to 07-02-90 07-02-90 07-02-90 07-02-90 07-02-90 07-02-90 07-02-90 07-02-90 07-02-90 07-02-90 07-02-90 07-02-90 to to to to to to 07-10-90 07-10-90 07-10-90 07-10-90 07-10-90 07-09-90 07-10-90 07-10-90 07-10-90 07-10-90 07-10-90 07-09-90 to to to to to to 07-17-90 07-17-90 07-17-90 07-17-90 07-17-90 07-16-90 07-17-90 07-17-90 07-17-90 07-17-90 07-17-90 07-16-90 to to to to to to 07-24-90 07-24-90 07-24-90 07-24-90 07-24-90 07-23-90 07-24-90 07-24-90 07-24-90 07-24-90 07-24-90 07-23-90 to to to to to to 07-31-90 07-31-90 07-31-90 07-31-90 07-31-90 07-30-90 AUGUST 07-31-90 07-31-90 07-31-90 07-31-90 07-31-90 07-30-90 to to to to to to 08-06-90 08-06-90 08-06-90 08-06-90 08-06-90 08-06-90 08-06-90 08-06-90 08-06-90 08-06-90 08-06-90 08-06-90 to to to to to to 08-14-90 08-14-90 08-14-90 08-14-90 08-14-90 08-13-90

TABLE C-5 (Cont'd) 1990 SAMPLING DATES FOR AIR SAMPLES

<------------------------------------ STATION CODE ------------------------------------>

MONTH 5Sl 5Dl 16El lFl 2F2 3H3 (Control)

AUGUST 08-14-90 08-14-90 08-14-90 08-14-90 08-14-90 08-13-90 to to to to to to 08-21-90 08-21-90 08-21-90 08-21-90 08-21-90 08-20-90 08-21-90 08-21-90 08-21-90 08-21-90 08-21-90 08-20-90 to to to to to to 08-28-90 08-28-90 08-28-90 08-28-90 08-28-90 08-27-90 SEPTEMBER 08-28-90 08-28-90 08-28-90 08-28-90 08-28-90 08-27-90 to to to to to to 09-04-90 09-04-90 09-04-90 09-04-90 09-04-90 09-04-90 09-04-90 09-04-90 09-04-90 09-04-90 09-04-90 09-04-90 to to to to to to 09-10-90 09-10-90 09-10-90 09-10-90 09-10-90 09-10-90

\\0

~

09-10-90 09-10-90 09-10-90 09-10-90 09-10-90 09-10-90 to to to to to to 09-17-90 09-17-90 09-17-90 09-17-90 09-17-90 09-17-90 09-17-90 09-17-90 09-17-90 09-17-90 09-17-90 09-17-90 to to to to to to 09-24-90 09-24-90 09-24-90 09-24-90 09-24-90 09-24-90 09-24-90 09-24-90 09-24-90 09-24-90 09-24-90 09-24-90 to to to to to to 10-01-90 10-01-90 10-01-90 10-01-90 10-01-90 10-01-90 OCTOBER 10-01-90 10-01-90 10-01-90 10-01-90 10-01-90 10-01-90 to to to to to to 10-09-90 10-09-90 10-09-90 10-09-90 10-09-90 10-07-90 (1) 10-09-90 10-09-90 10-09-90 10-09-90 10-09-90 10-09-90 to to to to to to 10-15-90 10-15-90 10-15-90 10-15-90 10-15-90 10-15-90 10-15-90 10-15-90 10-15-90 10-15-90 10-15-90 10-15-90 to to to to to to 10-22-90 10-22-90 10-22-90 10-22-90 10-22-90 10-22-90 10-22-90 10-22-90 10-22-90 10-22-90 10-22-90 to to to to to 10-29-90 10-29-90 10-29-90 10-27-90 (1) 10-29-90

\\!)

U1 TABLE C-5 (Cont'd) 1990 SAMPLING DATES FOR AIR SAMPLES

<------------------------------------ STATION CODE ------------------------------------>

MONTH 551 5Dl 16El lFl 2F2 3H3 (Control)

NOVEMBER 10-29-90 10-29-90 10-30-90 10-29-90 10-29-90 10-29-90 to to to to to to 11-05-90 11-05-90 11-05-90 11-05-90 11-05-90 11-05-90 11-05-90 11-05-90 11-05-90 11-05-90 11-05-90 11-05-90 to to to to to to 11-13-90 11-13-90 11-13-90 11-13-90 11-13-90 11-13-90 11-13-90 11-13-90 11-13-90 11-13-90 11-13-90 11-13-90 to to to to to to 11-19-90 11-19-90 11-19-90 11-19-90 11-19-90 11-19-90 11-19-90 11-19-90 11-19-90 11-19-90 11-19-90 11-19-90 to to to to to to 11-26-90 11-26-90 11-27-90 11-26-90 11-26-90 11-26-90 DECEMBER 11-26-90 11-26-90 11-27-90 11-26-90 11-26-90 11-26-90 to to to to to to 12-03-90 12-03-90 12-03-90 12-03-90 12-03-90 12-03-90 12-03-90 12-03-90 12-03-90 12-03-90 12-03-90 12-03-90 to to to to to to 12-10-90 12-10-90 12-10-90 12-10-90 12-10-90 12-10-90 12-10-90 12-10-90 12-10-90 12-10-90 12-10-90 12-10-90 to to to to to to 12-17-90.

12-17-90 12-17-90 12-17-90 12-17-90 12-17-90 12-17-90 12-17-90 12-17-90 12-17-90 12-17-90 12-17-90 to to to to to to 12-24-90 12-24-90 12-24-90 12-24-90 12-24-90 12-24-90 12-24-90 12-24-90 12-24-90 12-24-90 12-24-90 12-24-90 to to to to to to 12-31-90 12-31-90 12-31-90 12-31-90 12-31-90 12-31-90 (1) Reduced sampling period due_~d an air sampler malfunction.

(2) Shorter collection period for air filter due to component separation on sampler inlet to air iodine filter.

(2)

TABLE C-6 1990 CONCENTRATIONS OF GROSS ALPHA AND GROSS BETA EMITTERS, TRITIUM AND GAMMA EMITTERS* IN PRECIPITATION Results in Units of pCi/L +/- 2 sigma STATION ID:

SA-RWA-2F2 GROSS GROSS

<- GAMMA EMITTERS ->

SAMPLING PERIOD ALPHA BETA TRITIUM Be-7 12-26-89 to 01-29-90

<0.9

3. 7+/-1.3

<130 44+/-8 01-29-90 to 02-27-90

<1.6

4. 5+/-1. 5

<140 79+/-17 02-27-90 to 03-26-90

<1.2

<1.8

<140

<49 03-26-90 to 04-30-90 2.1+/-1.1 2.2+/-0.7

<140 76+/-34 04-30-90 to 05-30-90

<1.6 2.6+/-0.8

<140

<54 05-30-90 to 06-26-90

<1.8 1.4+/-0. 7

<140

<58 06-26-90 to 07-31-90

<1.2 3.7+/-0.9 150+/-80

<32 07-31-90 to 08-28-90

<1.5 3.5+/-0.9

<140 33+/-12 08-28-90 to 10-01-90 1.2+/-0.9 21+/-4

<150 160+/-45 10-01-90 to 10".'"29-90 1.8+/-1.0 5.5+/-2.6

<150 100+/-47 10-29-90 to 11-26-90

<0.5

1. 5+/-0. 8

<160

<66 11-26-90 to 12-31-90

<1.1 2.5+/-0.7

<150

<10 AVERAGE 4.5+/-11 63+/-78

  • All other ganuna emitters searched for were <LLD; typical LLDs are given in Table C-27.

96

TABLE C-7 1990 DIRECT RADIATION MEASUREMENTS -

QUARTERLY TLD RESULTS Results in mrad/standard month* +/- 2 (Results by Teledyne Isotopes)

JANUARY APRIL STATION ID to to MARCH JUNE SA-IDM-2S2 4.7+/-0.6 4.4+/-0.3 SA-IDM-551 4.2+/-0.2 3.9+/-0.3 SA-IDM-652 4.6+/-0.4 4.5+/-0.3 SA-IDM-7Sl 5.3+/-0.8 5.7+/-0.5 SA-IDM-lOSl 5.4+/-0.4 5.9+/-0.8 SA-IDM-llSl 4.0+/-0.5 8.1+/-2.0 SA-IDM-4D2 5.1+/-0.5 4.6+/-0.5 SA-IDM-5Dl 4.6+/-0.5 3.7+/-0.9 SA-IOM-1001 5.1+/-0.2 4.9+/-0.4 SA-IDM-1401 4.6+/-0.3 4.3+/-0.3 SA-IDM-2El 4.2+/-0.5 4.2+/-0.3 SA-IDM-3El 4.4+/-0.3 4.1+/-0.3 SA-IOM-:9El 5.5+/-0.5 5.1+/-0.5 SA-IOM-llE2 5.5+/-0.3 (1)

SA-IDM-12El 5.3+/-0.3 (1)

SA-IDM-13El 4.5+/-0.3 3.9+/-0.2 SA-IOM-16El 5.0+/-0.3 4.6+/-0.3 SA-IOM-lFl 4.7+/-0.3 4.3+/-0.2 SA-IDM-2F2 3.9+/-0.1 3.4+/-0.1 SA-IDM-2F5 4.9+/-0.2 3.9+/-0.6 SA-IDM-2F6 4.4+/-0.8 4.3+/-0.5 SA-IDM-3F2 4.4+/-0.4 3.8+/-0.1 SA-IDM-3F3 4.5+/-0.4 4.1+/-0.1 SA-IDM-5Fl 4.3+/-0.2 3.9+/-0.2 SA-IDM-6Fl 4.1+/-0.2 3.6+/-0.1 SA-I-DM-7F2 3.8+/-0.2 3.4+/-0.3 SA-IDM-10F2 5.1+/-0.5 (1)

SA-IDM-llFl 5.2+/-0.4 4.5+/-0.4 SA-IDM-12Fl 5.2+/-0.4 4.5+/-0.3 SA-IOM-13F2 4.8+/-0.5 4.4+/-0.2 SA-IOM-13F3 5.1+/-0.3 4.4+/-0.4 SA-IDM-13F4 4.8+/-0.3 4.5+/-0.3 SA-IDM-14F2 5.7+/-0.4 5.2+/-0.3 SA-IDM-15F3 5.3+/-0.6 5.0+/-0.4 SA-IOM-16F2 4.6+/-0.4 4.2+/-0.4 SA-IDM-1G3 (C) 5.7+/-0.5 (1)

SA-IDM-3Gl (C) 4.6+/-0.8 4.5+/-0.3 SA-IDM-lOGl (C) 5.3+/-0.3 4.5+/-0.3 SA-IOM-16Gl (C) 5.3+/-0.6 5.0+/-0.4 SA-IOM-3Hl (C) 5.0+/-0.2 4.7+/-0.2 SA-IDM-3H3 (C) 5.0+/-0.5 4.6+/-0.3 AVERAGE 4.8+/-1.0 4.5+/-1.6

  • The standard month = 30.4 days *

(C) Control Station (1) Results not reported by T.I.

97 JULY to SEPTEMBER 5.2+/-0.3 4.5+/-0.5 5.2+/-0.3 6.1+/-1. 6

7. 0+/-1. 0 10+/-3 5.6+/-0.4
4. 9+/-1. 0 5.4+/-0.2 5.2+/-0.5 4.9+/-0.6 4.5+/-0.9 5.8+/-0.6 6.0+/-0.6 5.5+/-0.8 4.8+/-0.4 5.3+/-0.6 5.4+/-0.7 4.1+/-0.8 5.5+/-0.4 5.4+/-0.2 4.7+/-0.7 5.0+/-0.1 5.0+/-0.6 5.1+/-0.5 4.2+/-0.3 6.2+/-0.5 5.8+/-0.4 5.6+/-0.3 5.5+/-0.2 5.7+/-0.4 5.4+/-0.3 6.3+/-0.4 6.2+/-0.3 5.1+/-0.2 5.9+/-0.9 5.6+/-0.6 5.5+/-0.9 5.6+/-0.8 4.8+/-0.2 5.6+/-0.3
5. 5+/-1. 9 sigma OCTOBER to DECEMBER 4.6+/-0.7 3.8+/-0.3 4.6+/-0.4 5.7+/-0.8 6.0+/-0.8 8.1+/-2.5 4.8+/-0.5 4.1+/-0.5 5.0+/-0.8 4.3+/-0.2 4.4+/-0.9 4.1+/-0.3 5.1+/-0.3 5.2+/-0.5 4.7+/-0.7 3.6+/-0.8 4.9+/-0.4 4.5+/-0.3 3.5£0.2 4.4+/-0.7 4.3+/-0.2 4.0+/-0.4 3.8+/-0.2 4.3+/-0.3 3.6+/-0.3 3.5+/-0.1 5.0+/-0.4 4.8+/-0.4 4.5+/-0.6 4.4+/-0.4 4.6+/-0.3 4.5+/-0.6 5.2+/-0.4 5.0+/-0.5 4.3+/-0.3 5.3+/-0.1

. 4. 7+/-0.4 4.9+/-0.6 5.1+/-0. 5 4.2+/-0.1 4.8+/-0.3

4. 6+/-1. 6 GRAND AVERAGE AVERAGE 4.7+/-0.7 4.1+/-0.6 4.7+/-0.6 5.7+/-0.7 6.1+/-1. 3 7.6+/-5.1 5.0+/-0.9 4.3+/-1.1 5.1+/-0.4 4.6+/-0.8 4.4+/-0.7 4.3+/-0.4 5.4+/-0.7 5.6+/-0.8 5.2+/-0.8 4.2+/-1.l 5.0+/-0.6 4.7+/-1.0 3.7+/-0.7 4.7+/-1.4
4. 6+/-1.1 4.2+/-0.8 4.4+/-1.0 4.4+/-0.9 4.1+/-1. 4
3. 7+/-0. 7 5.4+/-1.3 5.1+/-1.1
5. 0+/-1.1 4.8+/-1.0 5.0+/-1.2 4.8+/-0.8
5. 6+/-1. 0
5. 4+/-1.1 4.6+/-0.8 5.6+/-0.6 4.9+/-1.0 5.1+/-0. 9 5.3+/-0.5 4.7+/-0.7 5.0+/-0.9
4. 9+/-1. 7

TABLE C-8 1990 DIRECT RADIATION MEASUREMENTS -

MONTHLY TLD RESULTS Results in mrad/standard month* +/- 2 sigma (Results by Teledyne Isotopes)

STATION ID JANUARY FEBRUARY MARCH APRIL MAY JUNE SA-IDM-2S2 5.1+/-0.4 6.4+/-0.7 5.3+/-0.6 7.0+/-0.4 5.8+/-0.3

5. 5+/-1.0 SA-IDM-5Sl 4.4+/-0.3 5.9+/-0.2 3.5+/-1.8 5.8+/-0.5 5.4+/-0.4 5.0+/-0.5 SA-IDM-6S2 4.9+/-0.6 6.3+/-0.6 5.2+/-1.6 6.4+/-1.3 6.0+/-0.3 5.8+/-0.4 SA-IDM-7Sl 6.0+/-0.7 7.3+/-0.5 6.7+/-0.6 7.9+/-1.4 7.0+/-0.6 6.9+/-0.9 SA-IDM-10Sl 5.2+/-0.6 7.2+/-0.3 6.7+/-0.6 7.8+/-1.3
7. 3+/-1.1 7.9+/-1.2 SA-IDM-llSl 4.7+/-0.5 6.0+/-0.6 5,6+/-0.5 8.1+/-1.1 9.2+/-2.0 11+/-3 SA-IDM-5Dl 5.0+/-0.5 6.3+/-0.5 5.5+/-0.6 6.5+/-0.6 5.3+/-0.6 5.6+/-0.3 SA-IDM-10Dl 5.3+/-0.4 6.8+/-0.6 5.9+/-1.6 7.0+/-0.8 6.2+/-0.4 6.2+/-0.6 SA-IDM-14Dl 5.1+/-0.3 6.5+/-0.5 5.6+/-1.0 6.6+/-1.0 6.1+/-0.2 6.0+/-0.2 SA-IDM-2El 5.1+/-0. 5 6.3+/-0,5 5.5+/-0.2 6.5+/-0.3 5.7+/-0.4 5.6+/-0.4 SA-IDM-3El 4.6+/-0.4 6.1+/-0.5 5.1+/-1.1 6.4+/-0.5 5.4+/-0.7 5.4+/-0.3

\\0 SA-IDM-13El 4.7+/-0.7 6.0+/-0.5 5.5+/-0.5 5.9+/-0.4 5.6+/-0.6 5.8+/-0.5

())

SA-IDM-16El 5.0+/-0.1 6.5+/-0,6 5.8+/-0.8 7.0+/-0.8 5.7+/-0.6 5.8+/-0.2 SA-IDM-lFl 4.9+/-0.5 6.8+/-0.5 5.4+/-1.7 6.8+/-0.5 4.8+/-0.6 5.8+/-0.3 SA-IDM-2F2 4.2+/-0.2 5.5+/-0.4 4.8+/-0.4 5.7+/-0.3 5.2+/-0.4 5.1+/-0.3 SA-IDM-2F6 4.8+/-0.4 6.5+/-0.5 5.9+/-0.4 6.7+/-0.5 6.1+/-0. 5 5.6+/-0.3 SA-IDM-5Fl 4.7+/-0.5 6.3+/-0.3 5.5+/-0.6 6.3+/-1.0 5.7+/-0.3 5.5+/-0.4 SA-IDM-6Fl 4.2+/-0.3 5.6+/-0.3 5.1+/-0.4 5.8+/-0.4 5.1+/-1. 0 5.1+/-0.1 SA-IDM-7F2 3.8+/-0.2 5.4+/-0.3 4.6+/-0.3 5.6+/-0.3 4.9+/-0.1 4.9+/-0.2 SA-IDM-llFl 5.3+/-0.6 6.9+/-0.6 6.3+/-0.5 7.3+/-0.6 6.5+/-0.5 6.2+/-0.5 SA-IDM-13F4 5.0+/-0.5 6.5+/-0.5 6.1+/-0.4 6.9+/-0.3 6.3+/-0.7 6.2+/-0.8 SA-IDM-3Gl ( C) 5.4+/-0.4 6.7+/-0.5 5.9+/-0.5 7.0+/-0.6 6.3+/-0.6 6.1+/-0.2 SA-IDM-3Hl ( C) 5.2+/-0.2 6.8+/-0.5 5.9+/-0.4 7.0+/-0.2 6.3+/-0.6 6.0+/-0.2 SA-IDM-3H3 (C) 5.7+/-0.7 6.9+/-0.5 6.2+/-0.6 7.5+/-0.7 6.7+/-0.7 6.3+/-0.6 AVERAGE 4.9+/-1.0 6.4+/-1.0 5.6+/-1.4 6.7+/-1.4 6.0+/-1.9 6.1+/-2.5

TABLE C-8 (Cont'd) 1990 DIRECT RADIATION MEASUREMENTS -

MONTHLY TLD RESULTS Results in mrad/standard month* +/- 2 sigma (Results by Teledyne Isotopes)

STATION ID JULY AUGUST SEPTEMBER OCTOBER NOVEMBER DECEMBER AVERAGE SA-IDM-2S2 4.9+/-0.9 6.0+/-0.6 4.9+/-0.8

4. 9+/-1. 0 6.0+/-0.4 6.1+/-0.6 5.7+/-1.3 SA-IDM-5Sl 4.5+/-0.3 5.4+/-0.5 4.9+/-0.3 5.6+/-2.8 5.8+/-1.0 5.7+/-1.2
5. 2+/-1. 4 SA-IDM-6S2 5.1+/-0.6 5.8+/-0.5 5.3+/-0.7 5.4+/-0.8 6.3+/-0.7 6.1+/-0.3 5.7+/-1.0 SA-IDM-7Sl 6.2+/-0.8 7.3+/-0.8 7.0+/-0.6 6.5+/-2.8 7.1+/-2.6 7.7+/-0.'6 7.0+/-1.1 SA-IDM-lOSl
7. 0+/-1. 4 8.0+/-1.4
7. 5+/-1.2 7.4+/-2.3
7. 7+/-1. 2
7. 9+/-1.2 7.3+/-1.5 SA-IDM-llSl 9.5+/-3.1 12+/-4 10+/-4 9.7+/-3.3 8.8+/-0.5 9.8+/-2.6 8.7+/-4.3 SA-IDM-5Dl 4.8+/-0.3 5.8+/-0.5 5.6+/-0.6 5.7+/-0.5 6.0+/-0.6 5.9+/-0.3 5.7+/-0.9 SA-IDM-lODl 5.5+/-0.3 6.4+/-0.5 5.6+/-0.4
6. 3+/-1. 0 6.6+/-0.4 6.7+/-0.6 6.2+/-1.0 SA-IDM-14Dl 4.9+/-0.4 6.0+/-0.1 5.5+/-0.4 6.0+/-0.1 6.1+/-1.3 6.3+/-0.5 5.9+/-1.0 SA-IDM-2El 4.8+/-0.5 5.8+/-0.4 5.1+/-1. 6 5.7+/-1.3 6.1+/-0. 6 6.0+/-0.5
5. 7+/-1.0 SA-IDM-3El 4.7+/-0.3 5.4+/-0.2 4.1+/-0.5 5.7+/-1.0 6.1+/-0.3 5.7+/-0.4 5.4+/-1.3

~

SA-IDM-13El 4.7+/-0.5 5.6+/-0.3 5.4+/-0.4 5.8+/-1.7 6.0+/-0.7 5.8+/-0.3 5.6+/-0.9

~

SA-IDM-16El 5.3+/-0.4 5.9+/-0.4 5.7+/-0.4

5. 6+/-1. 8
6. 2+/-1. 9 6.5+/-0.4
5. 9+/-1.1 SA-IDM-lFl 5.1+/-0.6 6.0+/-0.4 5.4+/-0.3 6.2+/-0.3 6.2+/-1.4 6.2+/-0.3 5.8+/-1.3 SA-IDM-2F2 4.2+/-0.3 5.1+/-0.2 4.5+/-0.3 5.1+/-0.2 5.9+/-0.9 5.1+/-0.2 5.0+/-1.0 SA-IDM-2F6 5.0+/-0.5 5.7+/-0.4 5.3+/-0.7 5.1+/-1.5 5.9+/-1.2 5.8+/-0.4
5. 7+/-1.1 SA-IDM-5Fl 4.8+/-0.4 5.5+/-0.1 5.3+/-0.4 5.6+/-0.6 6.4+/-0.4 5.6+/-0.3
5. 6+/-1.0 SA-IDM-6Fl 4.2+/-0.1 5.3+/-0.5 4.6+/-0.3 5.2+/-0.7 4.6+/-0.9 5.0+/-0.4 5.0+/-1. 0 SA-IDM-7F2 4.0+/-0.1 4.7+/-0.2 4.4+/-0.3 4.8+/-2.0 4.7+/-1.4 4.8+/-0.2 4.7+/-1.0 SA-IDM-11Fl 5.5+/-0.5 6.2+/-0.5 6.1+/-0.5 6.2+/-0.6
6. 9+/-1. 4 6.6+/-0.5 6.3+/-1.1 SA-IDM-13F4 5.1+/-0. 3 5.9+/-0.4 5.5+/-0.4 5.9+/-1.5 6.2+/-1.4 6.2+/-0.4 6.0+/-1.1 SA-IDM-3Gl (C) 5.3+/-0.6 6.0+/-0.3 5.9+/-0.6 6.1+/-0.6 6.7+/-1.3 6.2+/-0.3 6.1+/-1.0 SA-IDM-3Hl (C) 5.0+/-0.3 5.9+/-0.3 5.3+/-0.3 5.2+/-2.4 6.1+/-0.8 6.1+/-0.3 5.9+/-1.2 SA-IDM-3H3 (C) 5.2+/-0.3 6.5+/-0.2 6.0+/-0.5 6.8+/-0.2 6.5+/-0.8 6.4+/-0.3
6. 4+/-1.1 AVERAGE 5.2+/-2.2 6.2+/-2.8 5.6+/-2.4 5.9+/-2.0
6. 3+/-1. 7 6.3+/-2.1 GRAND AVERAGE 5.9+/-2.1
  • The standard month 30.4 days (C) Control Station

TABLE C-9 1990 CONCENTRATIONS OF IODINE-131* AND GAMMA EMITTERS** IN MILK Results in Units of pCi/L +/- 2 sigma SAMPLING

<----- GAMMA EMITTERS ----->

STATION ID PERIOD I-131 K-40 Ra-226 SA-MLK-2F7 01/02-03/90

<0.3 1500+/-89

<3.4 SA-MLK-11F3 01/01-02/90

<0.2 1400+/-90

<4.2 SA-MLK-14Fl 01/02-03/90

<0.5 1400+/-100

<5.8 SA-MLK-3Gl (C) 01/02-03/90

<0.3 1400+/-99

<4.8 SA-MLK-2F7 02/05-06/90

<0.4 1300+/-98

<4.6 SA-MLK-11F3 02/04-05/90

<0.3 1400+/-72

<6.1 SA-MLK-14Fl 02/05-06/90

<0.5 1300+/-85

<3.8 SA-MLK-3Gl (C) 02/05-06/90

<0.2 1400+/-88

<4.8 SA-MLK-2F7 03/04-05/90

<0.3 1400+/-87

<3.9 SA-MLK-11F3 03/04-05/90

<0.3 1400+/-85

<4.1 SA-MLK-14Fl 03/05-06/90

<0.4 1400+/-71

<6.1 SA-MLK-3Gl (C) 03/05-06/90

<0.5 1400+/-100

<4.2 SA-MLK-2F7 04/01-02/90

<0.3 1300+/-88

<5.1 SA-MLK-11F3 04/01-02/90

<0.3 1300+/-82

<6.7 SA-MLK-14Fl 04/02-03/90

<0.4 1400+/-72

<7.5 SA-MLK-3Gl ( c) 04/02-03/90

<0.3 1400+/-99

<5.4 SA-MLK-2F7 04/16-17/90

<0.2 1400+/-85

<3.0 SA-MLK-11F3 04/16-17/90

<0.3 1300+/-82

<4.3 SA-MLK-14Fl 04/16-17/90

<0.2 1400+/-110

<12 SA-MLK-3Gl (C) 04/16-17/90

<0.3 1800+/-110

<3.4 SA-MLK-2F7 05/06-07/90

<0.3 1300+/-95

<5.1 SA-MLK-11F3 05/07-08/90

<0.2 1400+/-99

<3.4 SA-MLK-14Fl 05/06-07/90

<0.4 1200+/-85

<4.4 SA-MLK-3Gl (C) 05/06-07/90

<0.5 1400+/-88

<4.4 SA-MLK-2F7 05/20-21/90

<0.3 1400+/-89

<3.6 SA-MLK-11F3 05/21-22/90

<0.3 1300+/-100

<9.8 SA-MLK-14Fl 05/20-21/90

<0.3 1300+/-97

<9.4 SA-MLK-3Gl (C) 05/20-21/90

<0.4 1200+/-82

<4.0 SA-MLK-2F7 06/05-06/90

<0.2 1400+/-92

<3.4 SA-MLK-11F3 06/04-05/90

<0.2 1400+/-100

<5.1 SA-MLK-14Fl 06/04-05/90

<0.3 1300+/-87

<3.9 SA-MLK-3Gl (C) 06/05-06/90

<0.4 1200+/-80

<4.5 SA-MLK-2F7 06/19-20/90

<0.3 1300+/-90

<4.0 SA-MLK-11F3 06/18-19/90

<0.4 1300+/-98

<6.2 SA-MLK-14Fl 06/18-19/90

<0.3 1300+/-84

<3.8 SA-MLK-3Gl (C) 06/19-20/90

<0.3 1300+/-79

<3.8 SA-MLK-2F7 07/01-02/90

<0.2 1400+/-90

<3.5 SA-MLK-11F3 07/01-02/90

<0.5 1400+/-84

<2.9 SA-MLK-14Fl 07/01-02/90

<0.2 1400+/-100

<4.4 SA-MLK-3Gl (C) 07/01-02/90

<0.1 1400+/-92

<3.4 SA-MLK-2F7 07/17-18/90

<0.4 1500+/-99

<4.4 SA-MLK-11F3 07/17-18/90

<0.3 1300+/-86

<4.2 SA-MLK-14Fl 07/17-18/90

<0.4 1800+/-110

<4.7 SA-MLK-3Gl (C) 07/16-17/90

<0.4 1300+/-80

<4.2 100

TABLE C-9 (Cont'd) 1990 CONCENTRATIONS OF IODINE-131* AND GAMMA EMITTERS** IN MILK STATION ID SA-MLK-2F7 SA-MLK-11F3 SA-MLK-14Fl SA-MLK-3Gl (C)

SA-MLK-2F7 SA-MLK-11F3 SA-MLK-14Fl SA-MLK-3Gl (C)

SA-MLK-2F7 SA-MLK-llF3 SA-MLK-14Fl SA-MLK-3Gl (C)

SA-MLK-2F7 SA-MLK-11F3 SA-MLK-14Fl SA-MLK-3Gl (C)

SA-MLK-2F7 SA-MLK-11F3 SA-MLK-14Fl SA-MLK-3Gl (C)

SA-MLK-2F7 SA-MLK-11F3 SA-MLK-14Fl SA-MLK-3Gl (C)

SA-MLK-2F7 SA-MLK-11F3 SA-MLK-14Fl SA-MLK-3Gl (C)

SA-MLK-2F7 SA-MLK-11F3 SA-MLK-14Fl SA-MLK-3Gl (C)

SA-MLK-2F7 SA-MLK-11F3 SA-MLK-14Fl SA-MLK-3Gl (C)

AVERAGE Results in Units of pCi/L +/- 2 sigma SAMPLING PERIOD 08/06-07/90 08/05-05/90 08/06-07/90 08/06-07/90 08/20-21/90 08/20-21/90 08/20-21/90 08/20-21/90 09/03-04/90 09/03-04/90 09/03-04/90 09/03-04/90 09/17-18/90 09/17-18/90 09/17-18/90 09/16-17/90 10/08-09/90 10/08-09/90 10/08-09/90 10/08-09/90 10/21-22/90 10/21-22/90 10/21-22/90 10/21-22/90 11/04-05/90 11/04-05/90 11/04-05/90 11/04-05/90 11/18-19/90 11/18-19/90 11/18-19/90 11/18-19/90 12/02-03/90 12/02-03/90 12/02-03/90 12/02-03/90 I-131

<0.2

<0.4

<0.3

<0.4

<0.2

<0.3

<0.2

<0.2

<0.3

<0.5

<0.3

<0.4

<0.2

<0.2

<0.2

<0.3

<0.2

<0.2

<0.2

<0.2

<0.2

<0.1

<0.2

<0.4

<0.2

<0.3

<0.4

<0.3

<0.3

<0.2

<0.3

<0.3

<0.2

<0.2

<0.3

<0.1

<----- GAMMA EMITTERS ----->

K-40 Ra-226 1400+/-92 1400+/-89 1300+/-80 1300+/-92 1400+/-92 1300+/-98 1400+/-89 1200+/-81 1400+/-86 1500+/-95 1400+/-99 1300+/-89 1500+/-81 1400+/-91 1400+/-95 1300+/-83 1200+/-75 1400+/-90 1200+/-82 1400+/-97 1300+/-80 1600+/-100 1200+/-79 1300+/-87 1400+/-79 1400+/-110 1300+/-81 1400+/-88 1100+/-76 1400+/-96 1300+/-85 1400+/-88 1300+/-67 1400+/-98 1300+/-87 1700+/-110 1400+/-230

<4.1

<3.9

<12

<4.2

<4.0

<3.8

<6.4

<3.9

<3.9

<4.8

<9.8

<4.9

<3.8

<4.5

<12

<4.1 20+/-5

<4.5

<4.9

<5.0

<3.3

<4.2

<4.8

<4.3

<3.0

<4.0

<5.0

<4.7

<4.6

<4.9

<6.0

<7.8

<3.2

<5.1

<9.1

<4.2

  • Iodine-131 results are corrected for decay to midpoint of collection period.

Iodine-131 analyzed to a sensitivity of 1.0 pCi/liter.

    • All other gamma emitters searched for were <LLD; typical LLDs are given in Table C-27.
      • Monthly sample collected during Jan., Feb., March and Dec., when animals are not on pasture.

(C) Control Station 101

STATION ID SA-MLK-2F7 SA-MLK-11F3 SA-MLK-14Fl SA-MLK-3Gl (Control)

AVERAGE TABLE C-10 1990 CONCENTRATIONS OF STRONTIUM-89* AND STRONTIUM-90 IN MILK**

Results in Units of pCi/L +/- 2 sigma SAMPLING PERIOD

<--- STRONTIUM --->

Sr-89 Sr-90 06/19-20/90 06/18-19/90 06/18-19/90 06/19-20/90

<1.3

<1.0

<1.0

<1.2 4.6+/-0.6 1.8+/-0.4 1.7+/-0.4 3.0+/-0.5 2.8+/-2.7

  • Sr-89 results are corrected for decay to midpoint of collection period.
    • Management audit analyses, not required by Technical Specifications or by specific commitments to local officials.

TABLE C-11 1990 CONCENTRATIONS OF GROSS ALPHA AND GROSS BETA EMITTERS, POTASSIUM-40 AND TRITIUM IN WELL WATER Results in Units of pCi/L +/- 2 sigma SAMPLING GROSS GROSS STATION ID DATE ALPHA BETA K-40 TRITIUM SA-WWA-283 01-08-90

<1.5 4.0+/-0.9 3.7+/-0.4

<130 SA-WWA-3El (C) 01-08-90

<1.6 9.9+/-1. 2 9.9+/-1.0

<130 SA-WWA-2S3 02-13-90

<1.1 3.8+/-0.9 3.2+/-0.3

<130 SA-WWA-3El (C) 02-13-90

<1.2 10+/-1 8.8+/-0.9

<140 8A-WWA-2S3 03-12-90

<1.8 4.0+/-0.9 3.4+/-0.3

<140 8A-WWA-3El (C) 03-12-90

<1.6 10+/-1 8.6+/-0.9

<140 SA-WWA-283 04-09-90

<1.0 4.7+/-0.9 3.7+/-0.4

<140 8A-WWA-3El (C) 04-09-90

<1.2.

11+/-1 9.4+/-0.9

<140 SA-WWA-283 05-14-90

<1.3

9. 9+/-1. 2 7.0+/-0.7

<140 8A-WWA-3El (C) 05-14-90

<1.3

7. 7+/-1. l 8.1+/-0.8

<150 SA-WWA-283 06-26-90

<1.8 3.2+/-0.9 3.3+/-0.3

<140 SA-WWA-3El (C) 06-26-90

<1. 7 11+/-1

9. 9+/-1. 0

<140 8A-WWA-2S3 07-31-90

<1.2 2.5+/-0.8 3.1+/-0.3

<140 8A-WWA-3El (C) 07-31-90

<1.3

8. 7+/-1. 2 9.9+/-1.0

<140 SA-WWA-283 08-28-90

<1.6 3.0+/-0.8 4.0+/-0.4

<140 8A-WWA-3El (C) 08-28-90

<1.6

9. 8+/-1. 3 12+/-1

<140 SA-WWA-2S3 09-24-90

<0.8 3.0+/-0.8 3.2+/-0.3

<140 8A-WWA-3El (C) 09-24-90

<1.0 10+/-1 9.1+/-0.9

<140 8A-WWA-283 10-29-90

<0.7 3.0+/-0.8 4.0+/-0.4

<150 8A-WWA-3El (C) 10-29-90

<0.8 10+/-1 11+/-1

<150 8A-WWA-283 11-26-90 0.6+/-0.6 3.4+/-0.9 2.6+/-0.3

<160 8A-WWA-3El (C) 11-26-90 0.8+/-0.6

9. 3+/-1. 2 9.3+/-0.9

<150 8A-WWA-2S3 12-24-90

<1.2 4.6+/-0.9 4.4+/-0.4

<160 SA-WWA-3El (C) 12-24-90

<1.2 10+/-1 9.2+/-0.9

<160 AVERAGE SA-WWA-283 4.1+/-3.9 3.8+/-2.2 SA-WWA-3El (C) 9.8+/-1.8 9.6+/-2.1 GRAND AVERAGE 6.9+/-6.5 6.7+/-6.3 (C) Control Station 103

TABLE C-12 1990 CONCENTRATIONS OF IODINE-131* AND GAMMA EMITTERS** IN WELL WATER Results in Units of pCi/L +/- 2 sigma SAMPLING

<---- GAMMA EMITTERS ---->

STATION ID DATE I-131 K-40 Ra-226 SA-WWA-2S3 01-08-90

<0.3

<8.1

<4.7 SA-WWA-3El (C) 01-08-90

<0.2

<23 200+/-10 SA-WWA-2S3 02-13-90

<0.3 53+/-13 9.5+/-2.2 SA-WWA-3El (C) 02-13-90

<0.1 85+/-35 220+/-9 SA-WWA-2S3 03-12-90

<0.4

<18

<5.8 SA-WWA-3El (C) 03-12-90

<0.2 57+/-28 60+/-6 SA-WWA-2S3 04-09-90

<0.2

<19 7.6+/-3.2 SA-WWA-3El (C) 04-09-90

<0.2 52+/-16 19+/-4 SA-WWA-2S3 05-14-90

<0.4

<19 9.1+/-4.3 SA-WWA-3El (C) 05-14-90

<0.4

<24 55+/-6 SA-WWA-2S3 06-26-90

<0.2

<23

<3.2 SA-WWA-3El (C) 06-26-90

<0.3

<23 100+/-6 SA-WWA-2S3 07-31-90

<0.3

<42

<2.7 SA-WWA-3El (C) 07-31-90

<0.3

<42 120+/-8 SA-WWA-2S3 08-28-90

<0.3

<17

<2.8 SA-WWA-3El ( C) 08-28-90

<0.1

<23 100+/-7 SA-WWA-2S3 09-24-90

<0.1

<20

<7.5 SA-WWA-3El (C) 09-24-90

<0.2

<47 180+/-9 SA-WWA-2S3 10-29-90

<0.2

<18

<2.5 SA-WWA-3El (C) 10-29-90

<0.3

<20 170+/-8 SA-WWA-2S3 11-26-90

<0.3

<20

<2.7 SA-WWA-3El (C) 11-26-90

<0.3

<28 190+/-8 SA-WWA-253 12-24-90

<0.3

<17 9.8+/-5.4 SA-WWA-3El (C) 12-24-90

<0.1 88+/-34 220+/-10 AVERAGE SA-WWA-2S3 SA-WWA-3El (C) 140+/-140 GRAND AVERAGE 140+/-140

  • Iodine-131 analyzed to a sensitivity of 1.0 pCi/liter.
    • All other gamma emitters searched for were <LLD; typical LLDs are given in Table C-27.

(C) Control Station 104

TABLE C-13 1990 CONCENTRATIONS OF STRONTIUM-89* AND STRONTIUM-90 IN QUARTERLY COMPOSITES OF WELL WATER Results in Units of pCi/L

<-- STRONTIUM -->

STATION ID SAMPLING PERIOD Sr-89 SA-WWA-2S3 01-08-90 to 03-12-90

<1.4 SA-WWA-3El (C) 01-08-90 to 03-12-90

<0.7 SA-WWA-2S3 04-09-90 to 06-26-90

<0.6 SA-WWA-:-3El (C) 04-09-90 to 06-26-90

<0.5 SA-WWA-283 07-31-90 to 09-24-90

<1.0 SA-WWA-3El (C) 07-31-90 to 09-24-90

<0.6 SA-WWA-283 10-29-90 to 12-24-90

<1.1 SA-WWA-3El (C) 10-29-90 to 12-24-90

<0.8

  • Sr-90 results are corrected for decay to stop date of collection period.

(C) Control Station 105 Sr-90

<0.9

<0.5

<0.5

<0.4

<1. 0

<0.5

<0.8

<0.6

TABLE C-14 1990 CONCENTRATIONS OF GROSS ALPHA AND GROSS BETA EMITTERS, POTASSIUM-40 AND TRITIUM IN RAW AND TREATED POTABLE WATER Results in Units of pCi/L +/- 2 sigma STATION ID: SA-PWR/T-2F3 SAMPLING GROSS GROSS TYPE PERIOD ALPHA BETA K-40 TRITIUM Raw 01/01-31/90

<1.0 4.7+/-0.9 2.6+/-0.3

<140 Treated 01/01-31/90

<1.3 3.9+/-0.9 2.6+/-0.3

<150 Raw 02/01-28/90

<1.6 3.7+/-0.8 1.8+/-0.2

<170 Treated 02/01-28/90

<1.6 3.1+/-0.8

1. 7+/-0. 2

<140 Raw 03/01-31/90 1.3+/-1. 0 2.9+/-0.8

1. 7+/-0. 2

<140 Treated 03/01-~1/90

<1.0 2.3+/-0.7

1. 6+/-0. 2

<130 Raw 04/01-30/90

<1.3

6. 4+/-1. 0 1.4+/-0.1 140+/-90 Treated 04/01-30/90

<1.2 2.4+/-0.7 1.4+/-0. l

<140 Raw 05/01-31/90

<2.1 2.4+/-0.8 2.7+/-0.3

<140 Treated 05/01-31/90

<1.8 2.2+/-0.8

1. 6+/-0. 2

<140 Raw 06/01-30/90

<2.1 2.4+/-0.8 2.7+/-0.3

<140 Treated 06/01-30/90

<1.8 3.2+/-0.8 3.0+/-0.3

<140 Raw 07/01-31/90

<2.1 3.3+/-0.8 2.5+/-0.2

<140 Treated 07/01-31/90

<1. 5 2.9+/-0.8 2.0+/-0.2

<140 Raw 08/01-31/90

<1. 7 3.4+/-0.8 2.7+/-0.3

<140 Treated 08/01-31/90

<1.6 2.5+/-0.8 2.7+/-0.3

<140 Raw 09/01-30/90

<0.9 3.7+/-0.8 2.3+/-0.2

<150 Treated 09/01-30/90

<0.8 3.4+/-0.8 2.3+/-0.2

<150 Raw 10/01-31/90

1. 7+/-1.0 3.4+/-0.8 2.2+/-0.2

<150 Treated 10/01-31/90 1.1+/-0.8 3.0+/-0.7 2.2+/-0.2

<150 Raw 11/01-30/90 1.1+/-0. 7 2.6+/-0.8

1. 7+/-0. 2

<150 Treated 11/01-30/90 1.1+/-0. 7 3.3+/-0.9

1. 9+/-0. 2

<150 Raw 12/01-31/90

<1.3 2.8+/-0.7 2.0+/-0.2 160+/-90 Treated 12/01-31/90

<1.2 2.9+/-0.7 2.8+/-0.3

<150 AVERAGE Raw 3.5+/-2.3 2.2+/-0.9 Treated 2.9+/-1.0 2.2+/-1.1 GRAND AVERAGE 3.2+/-1. 8 2.2+/-1. 0 106

TABLE C-15 1990 CONCENTRATIONS OF IODINE-131* AND GAMMA EMITTERS**

IN RAW AND TREATED POTABLE WATER Results in Units of pCi/L +/- 2 sigma STATION ID: SA-PWR/T-2F3 SAMPLING

<------ GAMMA EMITTERS ----->

TYPE PERIOD I-131 K-40 Ra-226 Raw 01/01-31/90

<0.5

<40

<2.0 Treated 01/01-31/90

<0.8

<13

<3.0 Raw 02/01-28/90

<0.3

<20

<3.1 Treated 02/01-28/90

. <0.3 54+/-16

<2.5 Raw 03/01-31/90

<0.4

<33

<4.9 Treated 03/01-31/90

<0.2

<18

<2.7 Raw 04/01-30/90

<0.3

<22

<3.1 Treated 04/01-30/90

<0.4

<47

<2.2 Raw 05/01-31/90

<0.6

<19

<2.2 Treated 05/01-31/90

<0.2

<22

<3.1 Raw 06/01-30/90

<0.3

<18

<2.8 Treated 06/01-30/90

<0.2

<23

<3.3 Raw 07/01-31/90

<0.3

<44

<2.8 Treated 07/01-31/90

<0.4

<17

<3.5 Raw 08/01-31/90

<0.4

<36

<3.0 Treated 08/01-31/90

<0.5

<19

<2.9 Raw 09/01-30/90

<0.2

<47

<3.1 Treated 09/01-30/90

<0.2

<20

<6.3 Raw 10/01-31/90

<0.2

<20

<2.9 Treated 10/01-31/90

<0.1

<17 24+/-4.3 Raw 11/01-30/90

<0.2

<18

<3.2 Treated 11/01-30/90

<0.2

<21

<3.2 Raw 12/01-31/90

<0.2

<19

<2.8 Treated 12/01-31/90

<0.2

<19

<3.1

  • Iodine-131 analyzed to a sensitivity of 1.0 pCi/liter.
    • All other gamma emitters searched for were <LLD; typical LLDs are given in Table C-27.

107

TABLE C-16 1990 CQNCENTRATIONS OF STRONTIUM-89* AND STRONTIUM-90 IN QUARTERLY COMPOSITES OF RAW AND TREATED POTABLE WATER Results in Units of pCi/L +/- 2 sigma STATION ID: SA-PWR/T-2F3

<-- STRONTIUM -->

TYPE SAMPLING PERIOD Sr-89 Raw 01-01-90 to 03-31-90

<0.8 Treated 01-01-90 to 03-31-90

<0.9 Raw 04-01-90 to 06-30-90

<1.0 Treated 04-01-90 to 06-30-90

<0.8 Raw 07-01-90 to 09-30-90

<1.0 Treated 07-01-90 to 09-30-90

<0.6 Raw 10-01-90 to 12-31-90

<0.8 Treated 10-01-90 to 12-31-90

<0.7

  • Sr-90 results are corrected for decay to stop date of collection period.

108 Sr-90

<0.7

<0.9

<1. 0

<0.7

<0.8

<0.6

<0.8

<0.6

TABLE C-17 1990 CONCENTRATIONS OF GAMMA EMITTERS* IN VEGETABLES Results in Units of pCi/kg (wet) +/- 2 sigma SAMPLING

<- GAMMA EMITTERS ->

STATION ID DATE SAMPLE TYPE K-40

  • SA-FPV-3E2 06-13-90 Asparagus 2500+/-230 SA-FPV-2Gl (C) 05-01-90 Asparagus 2300+/-240 AVERAGE 2400+/-200 SA-FPL-3H5 (C) 07-25-90 Cabbage 1800+/-230 SA-FPL-5F3 07-31-90 Cabbage 3100+/-350 AVERAGE 2400+/-1300 SA-FPV-2F4 07-25-90 Corn 1900+/-180 SA-FPV-14F3 08-06-90 Corn 2600+/-250 SA-FPV-lGl (C) 07-24-90 Corn 2100+/-200 SA-FPV-3H5 (C) 07-25-90 Corn 2500+/-240 SA-FPV-3El 08-06-90 Corn 2700+/-220 AVERAGE 2400+/-610 SA-FPV-3E3 07-25-90 Peppers 1600+/-200 SA-FPV-14F3 08-06-90 Peppers 1700+/-180 SA-FPV-3H5 (C) 07-25-90 Peppers 2000+/-240 SA-FPV-lGl 08-01-90 Peppers 1700+/-210 AVERAGE 1800+/-300 SA-FPV-2F4 07-25-90 Tomatoes 2200+/-190 SA-FPV-14F3 08-06-90 Tomatoes 1900+/-180 SA-FPV-lGl (C) 08-01-90 Tomatoes 1900+/-160 SA-FPV-3H5 (C) 07-25-90 Tomatoes 1800+/-200 AVERAGE 2000+/-350 GRAND AVERAGE 2100+/-840
  • All other gamma emitters searched for were <LLD; typical LLDs are given in Table C-27.

109

TABLE C-18 1990 CONCENTRATIONS OF GAMMA EMITTERS* IN BEEF AND GAME Results in Units of pCi/kg (wet) +/- 2 sigma SAMPLING

<- GAMMA EMITTERS ->

STATION ID DATE SAMPLE TYPE K-40 SA-FPB-(1)

Beef (1)

SA-GAM-1101 02-03-90 Muskrat 2300+/-220 (Control)

SA-GAM-3El 01-26-90 Muskrat 2700+/-210 AVERAGE Muskrat 2500+/-600

  • All other gamma emitters searched for were <LLD; typical LLDs are given in Table C-27.

(1) No beef samples were available from any of our previous locations during the annual year.

110

TABLE C-19 1990 CONCENTRATIONS OF GAMMA EMITTERS* IN FODDER CROPS Results in Units of pCi/kg (wet) +/- 2 sigma SAMPLING

<---- GAMMA EMITTERS ---->

STATION ID DATE SAMPLE TYPE Be-7 K-40 SA-VGT-11F3 08-28-90 Green Chop 650+/-210 5400+/-590 SA-VGT-2F7 09-26-90 Corn Silage 460+/-120 3000+/-330 SA-VGT-11F3 08-28-90 corn Silage 460+/-200 5100+/-560 SA-VGT-14Fl 08-28-90 Corn Silage 540+/-170 3000+/-420 SA-VGT-3Gl ( c) 09-27-90 Corn Silage 600+/-160 3200+/-410 AVERAGE 520+/-140 3600+/-2000 SA-VGT-3El 11-03-90 Soybeans

<30 14000+/-530 SA-VGT-2F7 11-03-90 Soybeans

<60 12000+/-470 SA-VGT-3Gl ( c) 11-04-90 Soybeans

<70 14000+/-600 AVERAGE 13000+/-2300

  • All other gamma emitters searched for were <LLD; typical LLDs are given in Table C-27.

(C) Control Station 111

TABLE C-20 1990 CONCENTRATIONS OF GROSS ALPHA EMITTERS IN SURFACE WATER Results in Units of pCi/L +/- 2 sigma

<----------------------------------- STATION ID -------------------------->

SAMPLING SA-SWA-llAl SA-SWA-12Cl SA-SWA-7El SA-SWA-1F2 SA-SWA-16Fl AVERAGE DATE (Control) 01-15-90

<1.2 1.4+/-1.0

<1. 7

<1.6

<1.6 02-05-90

<2.0

<2.1

<2.0

<1. 8

<1. 7 03-05-90 2.1+/-1. 3

<1.5

<1.5

<1. 7

<1.4 I-'

04-06-90

<2.2

<1.7

<1.8

<1.8

<1.9 I-'

!\\.)

05-12-90

<2.2

<2.0

<2.2

<1. 7

<2.0 06-09-90

<2.1

<2.1

<2.1

<1.8

<1.9 07-06-90

<2.1

<2.2

<4.1

<1.9

<2.0 08-10-90 1.4+/-1.0

1. 0+/-0. 8 1.2+/-0.9 1.4+/-0.9
1. 7+/-1.0
1. 3+/-0. 5 09-10-90

<1.5

<1.6

<1.6 2.1+/-1.2

<1.4 10-12-90

<1.0 2.3+/-1.l

<1.1

1. 5+/-0. 9

<2.1 11-09-90 2.1+/-1. 2

1. 7+/-1.2

<1.5

<1.2

1. 5+/-1.1
1. 6+/-0. 7 12-07-90

<1.4

<1.4

<1.4

<1.2

<1.4

I-'

I-'

w SAMPLING DATE 01-15-90 02-05-90 03-05-90 04-06-90 05-12-90 06-09-90 07-06-90 08-10-90 09-10-90 10-12-90 11-09-90 12-07-90 AVERAGE TABLE C-21 1990 CONCENTRATIONS OF GROSS BETA EMITTERS IN SURFACE WATER Results in Units of pci/L +/- 2 sigma

<----------------------------------- STATION ID -------------------------->

SA-SWA-llAl SA-SWA-12Cl SA-SWA-7El SA-SWA-1F2 SA-SWA-16Fl AVERAGE (Control) 81+/-8 49+/-6 98+/-10 30+/-5 40+/-5 60+/-58 31+/-5 17+/-4 43+/-6 5.4+/-2.4 8.5+/-2.7 21+/-32 47+/-6 26+/-5 64+/-8 7.0+/-2.8 12+/-3 31+/-48 59+/-7 15+/-4 57+/-7 15+/-4 16+/-4 32+/-47 31+/-5 19+/-4 57+/-7 12+/-3 12+/-3 26+/-38 48+/-6 42+/-5 48+/-6 31+/-4 30+/-4 40+/-18 50+/-7 26+/-5 62+/-8 17+/-4 18+/-4 35+/-41 96+/-11 47+/-6 79+/-10 48+/-6 40+/-6 62+/-48 86+/-10 79+/-9 110+/-12 44+/-6 64+/-8 77+/-50 66+/-8 53+/-6 80+/-9 46+/-6 45+/-6 58+/-30 90+/-10 60+/-7 96+/-10 31+/-5 39+/-6 63+/-58 26+/-4 17+/-4 61+/-7 12+/-3 14+/-3 26+/-41 59+/-49 38+/-41 71+/-42 25+/-31 28+/-35 GRAND AVERAGE 44+/-53

TABLE C-22 1990 CONCENTRATIONS OF IODINE-131* AND GAMMA EMITTERS**

IN SURFACE WATER Results in Units of 10-3 pCi/L +/- 2 sigma SAMPLING

<---- GAMMA EMITTERS ---->

STATION ID DATE I-131 K-40 Th-232 SA-SWA-llAl 01/15/90

<0.6 68+/-23

<5.2 SA-SWA-12Cl (C) 01/15/90

<0.3 94+/-33

<5.9 SA-SWA-7El 01/15/90

<0.4 140+/-41

<5.8 SA-SWA-1F2 01/15/90

<0.5 67+/-14

<4.5 SA-SWA-16Fl 01/15/90

<0.5

<20

<4.7 SA-SWA-llAl 02/05/90

<0.5

<22

<5.9 SA-SWA-12Cl (C) 02/05/90

<0.9 62+/-19

<5.1 SA-SWA-7El 02/05/90

<0.5

<55

<5.1 SA-SWA-1F2 02/05/90

<0.6

<19

<5.0 SA-SWA-16Fl 02/05/90

<0.4

<18

<2.8 SA-SWA-llAl 03/05/90

<0.1 97+/-23

<4.4 SA-SWA-12Cl (C) 03/05/90

<0.4 74+/-27

<4.6 SA-SWA-7El 03/05/90

<0.4 110+/-15

<4.8 SA-SWA-1F2 03/05/90

<0.4

<19

<3.9 SA-SWA-16Fl 03/05/90

<0.4 61+/-13 4.7+/-2.8 SA-SWA-llAl 04/06/90

<0.3 65+/-20

<2.4 SA-SWA-12Cl (C) 04/06/90

<0.4

<19

<4.0 SA-SWA-7El 04/06/90

<0.4 110+/-26

<5.6 SA-SWA-1F2 04/06/90

<0.8 63+/-19

<3.6 SA-SWA-16Fl 04/06/90

<0.4

<22

<5.6 SA-SWA-llAl 05/12/90

<0.2 62+/-22

<4.3 SA-SWA-12Cl (C) 05/12/90

<0.4

<22

<5.4 SA-SWA-7El 05/12/90

<0.3 80+/-30

<4.6 SA-SWA-1F2 05/12/90

<0.5

<27

<4.2 SA-SWA-16Fl 05/12/90

<0.2

<24

<4.9 SA-SWA-llAl 06/09/90

<0.3 56+/-22

<4.6 SA-SWA-12Cl (C) 06/09/90

<0.2

<24

<6.2 SA-SWA-7El 06/09/90

<0.4 31+/-25

<4.9 SA-SWA-1F2 06/09/90

<0.4

<19

<4.8 SA-SWA-16Fl 06/09/90

<0.4

<20

<3.6 SA-SWA-llAl 07/06/90

<0.4 120+/-21

<4.7 SA-SWA-12Cl (C) 07/06/90

<0.3 140+/-30

<5.4 SA-SWA-7El 07/06/90

<0.3 140+/-28

<4.5 SA-SWA-1F2 07/06/90

<0.3 34+/-20

<5.6 SA-SWA-16Fl 07/06/90

<0.4 45+/-23

<5.3 114

TABLE C-22 (Cont'd) 1990 CONCENTRATIONS OF IODINE-131* AND GAMMA EMITTERS**

IN SURFACE WATER Results in Units of 10-3 pCi/L +/- 2 sigma SAMPLING

<---- GAMMA EMITTERS ---->

STATION ID DATE I-131 K-40 Th-232 SA-SWA-llAl 08/10/90

<0.5 140+/-24

<5.4 SA-SWA-12Cl (C) 08/10/90

<0.4 110+/-27

<5.4 SA-SWA-7El 08/10/90

<0.2 170+/-26

<4.4 SA-SWA-1F2 08/10/90

<0.2

<26

<4.6 SA-SWA-16Fl 08/10/90

<0.5 74+/-18

<3.6 SA-SWA-llAl 09/10/90

<0.2 98+/-26

<5.4 SA-SWA-12Cl (C) 09/10/90

<0.3 110+/-21

<4.6 SA-SWA-7El 09/10/90

<0.2 110+/-23

<3.2 SA-SWA-1F2 09/10/90

<0.3 110+/-30

<4.6 SA-SWA-16Fl 09/10/90

<0.3 100+/-21

<2.6 SA-SWA-llAl 10/12/90

<0.3 130+/-29

<5.2 SA-SWA-12Cl (C) 10/12/90

<0.5 54+/-23

<4.6 SA-SWA-7El 10/12/90

<0.3 97+/-25

<4.6 SA-SWA-1F2 10/12/90

<0.3 92+/-16

<2.9 SA-SWA-16Fl 10/12/90

<0.2 45+/-26

<4.1 SA-SWA-llAl 11/09/90

<0.5 84+/-27

<5.6 SA-SWA-12Cl (C) 11/09/90

<0.4 52+/-21

<4.8 SA-SWA-7El 11/09/90

<0.5 87+/-26

<4.6 SA-SWA-1F2 11/09/90

<0.3

<24

<5.9 SA-SWA-16Fl 11/09/90

<0.6 36+/-20

<4.6 SA-SWA-llAl 12/07/90

<0.3 62+/-18

<6.1 SA-SWA-12Cl (C) 12/07/90

<0.3

<20

<4.0 SA-SWA-7El 12/07/90

<0.3 62+/-24

<6.2 SA-SWA-1F2 12/07/90

<0.4

<19

<4.4 SA-SWA-16Fl 12/07/90

<0.5

<22

<5.3 AVERAGE 66+/-82

  • Iodine-131 results are corrected for decay to endpoint of collection period.
    • All other gamma emitters searched for were <LLD; typical LLDs are given in Table C-27.

(C) Control Station 115

Table C-23 1990 CONCENTRATIONS OF TRITIUM IN QUARTERLY COMPOSITES OF SURFACE WATER Results in Units of pCi/L +/- 2 sigma

<----------------------------------- STATION ID -------------------------->

SAMPLING SA-SWA-llAl SA-SWA-12Cl SA-SWA-7El SA-SWA-1F2 SA-SWA-16Fl AVERAGE PERIOD (Control) 01-15-90 to

<140

<140

<140

<140

<170 03-05-90 04-06-90 to 150+/-90 160+/-90 180+/-80

<150 150+/-90 160+/-30 06-09-90 O'I 07-06-90 to 230+/-90 160+/-90

<150

<150

<140 09-10-90 10-12-90 to

<150

<150

<160

<150

<150 12-07-90 AVERAGE 170+/-80 150+/-20 GRAND AVERAGE 160+/-50

I-'

I-'

.....i TABLE C-24 1990 CONCENTRATIONS OF STRONTIUM-89* AND STRONTIUM-90, TRITIUM AND GAMMA EMITTERS** IN EDIBLE FISH Results in Units of pCi/kg (wet) +/- 2 sigma (Except for strontium in bone analyses which are reported in pCi/kg (dry))

STRONTIUM SAMPLING PERIOD

<-- BONES --->

sr-89 sr-90

<---- FLESH--->

TRITIUM (FLESH)

AQUEOUS FRACTION

<-GAMMA EMITTERS (FLESH)->

STATION ID Sr-89 sr-90 SA-ESF-llAl 05/03-05/90

<63 280+/-16

<32

<24

<200 SA-ESF-12Cl (C) 05/03-05/90

<73 320+/-19

<34

<26

<200 SA-ESF-7El 05/03-05/90

<63 250+/-16

<31

<23

<200 AVERAGE 280+/-70 SA-ESF-llAl 10/02-06/90

<29 45+/-10

<25

<19

<1000 SA-ESF-12Cl (C) 10/02-06/90

<29 25+/-10

<27

<20

<1000 SA-ESF-7El 10/02-06/90

<30

<22

<26

<19

<1000 AVERAGE 30+/-25 GRAND AVERAGE 160+/-280

  • Sr-89 results are corrected for decay to sample stop date.
    • All other gamma emitters searched for were <LLD; typical LLDs are given in Table C-27.
      • Tritium results by Controls for Environmental Pollution, Inc.

(C) Control Station K-40 Ra-226 3200+/-220

<12 3000+/-200

<8.5 3100+/-240

<7.9 3100+/-200 3100+/-240 32+/-14 3100+/-220

<12 3600+/-230

<20 3300+/-580 3200+/-430

I-'

I-'

():)

TABLE C-25 1990 CONCENTRATIONS OF STRONTIUM-89* AND STRONTIUM-90, TRITIUM AND GAMMA EMITTERS** IN BLUE CRABS Results in Units of pCi/kg (wet) +/- 2 sigma (Except for strontium in shell analyses which are reported in pCi/kg (dry))

SAMPLING.

STATION ID DATE SA-ECH-llAl 06/20-21/90 SA-ECH-12Cl ( c) 06/20-21/90 AVERAGE SA-ECH-llAl 10/11-12/90 SA-ECH-12Cl ( c) 10/15-16/90 AVERAGE GRAND AVERAGE

<----------- STRONTIUM ---------->

<--- FLESH --->

Sr-89 Sr-90 32+/-13

<28 30+/-4

<24

<21

<18

<18

<20

<18

<--- SHELL --->

sr-89 sr-90

<41

<52

<36

<50 220+/-14 340+/-19 280+/-120 230+/-15 670+/-24 450+/-440 360+/-360

  • Sr-89 results are corrected for decay to sample stop date.

TRITIUM (FLESH)

AQUEOUS FRACTION 700+/-400

<1000 850+/-300

<1000

<1000

    • All other gamma emitters searched for were <LLD; typical LLDs are given in Table C-27.
      • Tritium results by Controls for Environmental Pollution, Inc.

(C) Control Station GAMMA EMITTER K-40 2800+/-210 2000+/-190 2400+/-800 2300+/-180 2700+/-190 2500+/-400 2400+/-640

I-'

I-'

\\0 TABLE C-26 1990 CONCENTRATIONS OF STRONTIUM-90 AND GAMMA EMITTERS* IN SEDIMENT Results in Units of pCi/kg (dry) +/- 2 sigma SAMPLING

<--------------------------- GAMMA EMITTERS --------------------------->

STATION ID DATE Sr-90 K-40 Mn-54 Co-58 Co-60 Cs-137 SA-ESS-llAl 05-28-90

<21 2700+/-190 28+/-9 230+/-18 45+/-14

<18 SA-ESS-15Al 05-28-90

<20 8500+/-380

<21

<35

<25 68+/-16 SA-ESS-16Al 05-28-90

<23 5200+/-260 48+/-13

<13 50+/-18 27+/-14 SA-ESS-12Cl (C) 05-28-90

<23 17000+/-560

<11

<12

<17

<8.8 SA-ESS-7El 05-28-90

<19 11000+/-390

<9.9

<12

<42 41+/-14 SA-ESS-16Fl 05-28-90

<25 14000+/-440

<12

<13

<10

<9.4 AVERAGE 9700+/-11000 29+/-45 lA-ESS-llAl 11-01-90

<20 5200+/-230

<6.0 28+/-9

<20

<5.5 SA-ESS-15Al 11-01-90

<21 6500+/-310

<9.4

<13 87+/-20 43+/-21 SA-ESS-16Al 11-01-90

<22 3600+/-200 36+/-10 45+/-13 42+/-20

<7.2 SA-ESS-12Cl (C) 11-01-90

<22 17000+/-570

<12

<11

<21

<9.1 SA-ESS-7El 11-01-90

<20 13000+/-400

<10

<26

<54 74+/-16 SA-ESS-16Fl 11-01-90

<22 16000+/-470

<11

<23

<14 62+/-22 AVERAGE 10000+/-12000 34+/-61 GRAND AVERAGE 10000+/-11000 31+/-51

  • All other gamma emitters searched for were <LLD; typical LLDs are given in Table C-27.

(C) Control Station Ra-226 Th-232 120+/-18 120+/-41 500+/-35 680+/-82 1300+/-42 890+/-70 640+/-45 990+/-95 660+/-39 660+/-65 590+/-39 860+/-88 640+/-760 700+/-620 360+/-24 430+/-43 470+/-33 650+/-60 370+/-26 510+/-47 560+/-39 940+/-88 800+/-40 860+/-81 570+/-38 840+/-86 520+/-330 700+/-400 580+/-570 700+/-500

TABLE C-27 1990 PSE&G RESEARCH & TESTING LABORATORY LLDs FOR GAMMA SPECTROMETRY SAMPLE TYPE:

<------------AIR------------>

<-------~ATER------->

IODINE PARTICULATES GAMMA SCAN IODINE ACTIVITY:

10-3 pCi/m3 10-3 pCi/M3 pCi/L pCi/L GEOMETRY:

100 ML 13 FILTERS 3_5 LITER 100 ML COUNT TIME:

120 MINS 1000 MINS 100 MINS 1000 MINS DELAY TO COUNT:

2 DAYS 5 DAYS 7 DAYS 3 DAYS NUCLIDES BE-7 6.8 15 NA-22 0.45 11 K-40 7.1 35 CR-51 2.9 16 MN-54 0.32

1. 7 C0-58 0.33 1.6 FE-59 0.79 3.7 C0-60 0.36 2.1 ZN-65 0.69 3.9 NB-95 0.49 ZR-95 0.44 ZRNB-95 3

M0-99 550 200 RU-103 0.33 1.6 RU-106 2.9 14 AG-100m 0.55 2.0 SB-125 0.77 4.0 TE-129m 120 62 I-131 13.0 0.98 3.8 0.60 TE-132 41 13 BA-133 3.7 CS-134 0_39 1.8 CS-136 0.56 2.9 CS-137 0.28 1.6 BA-140 2.2 LA-140 BALA-140 15 CE-141 0.31 2.3 CE-144 1

<--------MILK------->

GAMMA SCAN IODINE pCi/L pCi/L 3.5 LITER 100 ML 500 MINS 1000 MINS 2 DAYS 2 DAYS 22 4.5 120 22 3.4 2.9 7.2 4.0 8.6

3. 1 5.7 41 2.5 28 3.4 8.2 99 3.2 0.42 3.9 3.0 3.3 3.2 15 3.9 17 6.6 12

SAMPLE TYPE:

ACTIVITY GEOMETRY:

COUNT TIME:

DELAY TO COUNT:

NUCLIDES BE-7 NA-22 K-40 CR-51 MN-54 C0-58 FE-59 C0-60 ZN-65 NB-95 ZR-95 ZRND-95 M0-99 RU-103 RU-106 AG-110m SB-125 TE-129m I-131 TE-132 BA-133 CS-134 CS-136 CS-137 BA-140 LA-140 BALA-140 CE-141 CE-144 RA-226 TH-232 TABLE C-27 (cont'd) 1990 PSE&G RESEARCH & TESTING LABORATORY LLDs FOR GAMMA SPECTROMETRY

<------FOOD PRODUCTS------->

FODDER &

BEEF GREEN CHOP

& GAME pCi/KG WET pCi/kg WET pCi/kg WET 100 ml 400 ml 400 ml 400 ml 1000 MINS 1000 MINS 1000 MINS 1000 MINS 10 DAYS 3 DAYS 3 DAYS 10 DAYS 0.99 96 96 84 2.1 14 14 13 32 84 84 84 9.2 83 83 78

1. 2 13 13 11
1. 8 12 12 11 3.6 26 26 24 2.3 16 16 15 3.6 30 30 26 2.0 12 12 11 2.2 24 24 19 96 320 320 540
1. 0 9.4 9.4 9.2 12 100 100 82 2.2 22 22 9.5 2.8 26 26 22 4.7 460 460 400 2

15 15 19 4.4 22 22 55 0.96 10 10 8.3

1. 5 16 16 16 1.4 22 22 15 6.0 49 49 50 2.2 19 19 20 1.0 13 13 11 4.2 46 46 49 2.3 27 27 25 6.1 53 53 41 121 FISH SEO IMENT SHELLFISH

& SOIL pCi/kg WET pCi/kg DRY 400 ml 100 ml 1000 MINS 1000 MINS 10 DAYS 30 DAYS 84 200 13 27 84 640 78 220 11 20 11 23 24 51 15 30 26 42 11 36 19 43 540 290000 9.2 22 82 180 9.5 32 22 43 400 920 19 220 55 11000 8.3 14 16 86 15 22 50 270 20 97 11 39 49 88 25 46 41 122

APPENDIX D SYNOPSIS OF ANALYTICAL PROCEDURES 123

APPENDIX D SYNOPSIS OF ANALYTICAL.PROCEDURES Appendix D presents a synopsis of the analytical procedures utilized by the PSE&G Research and Testing Laboratory and contract laboratories for analyzing the 1990 Artificial Island Radiological Environmental Monitoring Program samples.

LAB*

PSE&G PSE&G PSE&G PSE&G PSE&G PSE&G CEP PSE&G PSE&G PSE&G PSE&G PSE&G PSE&G PSE&G PSE&G PSE&G TABLE OF CONTENTS PROCEDURE DESCRIPTION GROSS ALPHA Analysis of Air Particulates *.*....***.*..*..*..

Analysis of Water...............................

GROSS BETA Analysis of Air Particulates **..*...*..******.*.

Analysis of Water...............................

POTASSIUM-40 Analysis of Water...............................

TRITIUM Analysis of Water...............................

Analysis of Aqueous Fraction of Fish and Crab.**

IODINE-131 Analysis of Filtered Air ****.*******..*.***.**..

Analysis of Raw Milk *.*****.*..***..*..*........

STRONTIUM-89 AND STRONTIUM-90 Analysis of Air Particulates **.*****.....****.**

Analysis of Raw Milk............................

Analysis of Water...............................

Analysis of Vegetation, Meat and Aquatic Samples Analysis of Bone and Shell **..******...*********

Analysis of Soil and Sediment **********.***.*.**

Analysis of Samples for Stable Strontium *.*.*...

125 PAGE 127 129 130 132 133 134 135 136 137 138 141 144 147 150 153 156

SYNOPSIS OF ANALYTICAL PROCEDURES (cont'd)

TABLE OF CONTENTS

  • LAB*

PROCEDURE DESCRIPTION PAGE GAMMA SPECTROMETRY PSE&G Analysis of Air Particulates....................

158 PSE&G Analysis of Raw Milk............................

159 PSE&G Analysis of water...............................

160 PSE&G Analysis of Solids (combined procedures)........

161 ENVIRONMENTAL DOSIMETRY TI Analysis of Thermoluminescent Dosimeters..*.....

162

  • PSE&G -

PSE&G Research and Testing Laboratory CEP

- Controls for Environmental Pollution, Inc.

TI

- Teledyne Isotopes 126

SYNOPSIS OF PSE&G RESEARCH AND TESTING LABORATORY PROCEDURE GROSS ALPHA ANALYSIS OF AIR PARTICULATE SAMPLES After allowing at least a three-day (extending from the sample stop date to the sample count time) period for the short-lived radionuclides to decay out, air particulate samples are counted for gross alpha activity on a low back-ground gas proportional counter.

Along with a set of air particulate samples, a clean air filter is included as a blank with an Am-241 air filter geometry alpha counting standard.

The specific alpha activity is computed on the basis of total corrected air flow sampled during the collection period.

This corrected air flow takes into account the air pressure correction due to the vacuum being drawn, the correction factor of the temperature-corrected gas meter as well as the gas meter efficiency itself~

Calculation of Gross Alpha Activity:

Air flow is corrected first by using the following equations:

P = (B-V)/29.92 v

F*P*0.946*0.0283 E

p B

v 29.92 F

0.946 0.0283 E

v p

=

=

=

=

Pressure correction factor Time-averaged barometric pressure during sampling period, "Hg Time-averaged vacuum during sampling period, "Hg Standard atmospheric pressure at 32°F, "Hg Uncorrected air flow, ft3 Temperature correction factor from 60°F to 32°F Cubic meters per cubic foot Gas meter efficiency (= %

efficiency/100)

Corrected air flow, m3 Pressure correction factor Using these corrected air flows, the gross alpha activity is computed as follows:

Result (pCi/m3)

(G-B)/T (2.22)*(E)*(V)

G = Sample gross counts B

Background counts (from blank filter)

T Count time of sample and blank, mins.

E = Fractional Am-241 counting efficiency v

Corrected air flow of sample, m3 2.22 No. of dpm per pCi 127

2-sigrna error (pCi/m3)

(l.96*(G+B)1/2)*A (G-B)

Calculation of lower limit of detection:

A Gross alpha activity, pCi/m+3 G

Sample gross counts B

Background counts (from blank filter)

A sample activity is assumed to be LLD if the sample net count is less than 4.66 times the standard deviation of the count on the blank.

LLD(pCi/m3) =

4.66 * (B)1/2 (2.22)*(E)*(V)*(T) 128 B

Background counts (from blank filter)

E v

T Fractional Am-241 counting efficiency Corrected air flow of sample, m3 Count time of blank, mins.

SYNOPSIS OF PSE&G RESEARCH AND TESTING LABORATORY PROCEDURE GROSS ALPHA ANALYSIS OF WATER SAMPLES Water samples require pretreatment of all suspended material for the purpose of keeping the final sample thickness to a minimum.

This is accomplished by filtering a measured aliquot of the sample (while the filtrate is set aside) and ashing the collected residue in a crucible. A blank of the same volume is handled in the same manner. Whatever leftover sample residue remains,after the ashing,is dissolved in concentrated nitric acid and passed through a hardened fast filter paper and combined with the sample filtrate.

The combined sample is then neutralized with dilute ammonium hydroxide.

From this point, both sample and blank are acidified with dilute sulfuric acid.

Barium carrier is added and the sample is heated to 50°C in order to help precipitate barium sulfate.

Maintaining the same temperature for the remainder of the procedure, iron carrier is then introduced.

After a 30 minute equilibration period, the sample is neutralized with dilute ammonium hydroxide to precipitate ferric hydroxide.

The mixed precipitates are then filtered onto a membrane filter, dried under an infrared heat lamp, weighed and mounted on a stainless steel planchet.

The sample is then alpha-counted for the appropriate time on a low background gas proportional counter, along with a U-238 source of the same geometry.

The blank is treated in the same manner as the sample.

ca~.culation of Gross Alpha Activity:

Result (pCi/L) =

(G-B)/T (2.22)*(E)*(V)*(S)

G Sample gross counts B = Background counts (from blank sample)

T = Count time of sample and blank E

Fractional counting efficiency from U-238 source V = Sample volume, liters S = Normalized efficiency regression equation as a function of thick-ness 2.22 = No. of dpm per pCi 2-sigma error (pCi/L) = (1.96*(G+B)1/2)*A (G-B)

A = Gross alpha activity, pCi/L G = Sample gross counts B

Background counts (from blank sample)

SYNOPSIS OF PSE&G RESEARCH AND TESTING LABORATORY PROCEDURE GROSS BETA ANALYSIS OF AIR PARTICULATE SAMPLES After allowing at least a three-day (extending from the sample stop date to the sample count time) period for the short-lived radionuclides to decay out, air particulate samples are counted for gross beta activity on a low back-ground gas proportional counter.

Along with a set of air particulate samples, a clean air filter is included as a blank with an Sr-90 air filter geometry beta counting standard *

. The gross beta activity is computed on the basis of total corrected air flow sampled during the collection period.

This corrected air flow takes into account the air pressure correction due to the vacuum being drawn, the correction factor of the temperature-corrected gas meter as well as the gas meter efficiency itself.

Calculation of Gross Beta Activity:

Air flow is corrected first by using the following equations:

P = (B-V)/29.92 V

F*P*0.946*0.0283 E

P = Pressure correction factor B = Time-averaged barometric pressure during sampling period, "Hg V = Time-averaged vacuum during sampling period, "Hg 29.92 = Standard atmospheric pressure at 32°F, "Hg F = Uncorrected air flow, ft3 0.946 = Temperature correction factor from 60°F to 32°F 0.0283 = Cubic meters per cubic foot E = Gas meter efficiency (= %

efficiency/100)

V Corrected air flow, m3 P = Pressure correction factor Using these corrected air flows, the gross beta activity is computed as follows:

Result (pCi/m3) =

(G-B)/T (2.22)*(E)*(V)

G Sample gross counts B = Background counts (from blank filter)

T Count time of sample and blank, mins.

E = Fractional Sr-90 counting efficiency v

Corrected air flow of sample, m3 2.22 No. of dpm per pCi 130

2-sigma error (pCi/m3)

(l.96*(G+B)1/2)*A (G-B)

Calculation of lower limit of detection:

A = Gross beta activity, pCi/m3 G = Sample gross counts B

Background counts (from blank filter)

A sample ac~ivity is assumed to be LLD-if the sample net count is less than 4.66 times the standard deviation of the count on the blank.

LLD(pCi/m3) =

4.66 * (B)1/2 (2.22)*(E)*(V)*(T) 131 B

E v

T

=

=

=

=

Background counts (from blank filter)

Fractional Sr-90 counting efficiency Corrected air flow of sample, m3 Count time of blank, mins.

SYNOPSIS OF PSE&G RESEARCH AND TESTING LABORATORY PROCEDURE GROSS BETA ANALYSIS OF WATER SAMPLES The sample is mixed thoroughly.

Then, a 1.0 liter portion is removed from the potable, rain or well water container and 250ml taken from each surface water.

A deionized water blank is prepared for each different volume of sample (e.g.

1.0 liter blank for 1.0 liter samples and 250ml for 250ml samples).

All samples and blanks are then evaporated on a hotplate until the volume approaches 20 to 25ml.

At that point, the samples and blanks are transferred to tared stainless steel ribbed planchets and evaporated to dryness under an infrared heat lamp.

They are subsequently cooled in a desiccator, weighed and counted on a low background gas proportional counter along with an sr-90 source of the same geometry.

Calculation of Gross Beta Activity:

Result (pCi/L) =

(G-B)/T (2.22)*(E)*V)*(S)

G Sample gross counts B = Background counts (from blank sample)

T = Count time of sample and blank E

Fractional counting efficiency from sr-90 source V = Sample volume, liters s

Normalized efficiency regression equation as a function of thick-ness 2.22 = No. of dpm per pCi 2-sigma error (pCi/L) = (l.96*(G+B)1/2)*A (G-B) 132 A

Gross beta activity, pCi/L G = Sample gross counts B = Background counts (from blank sample)

SYNOPSIS OF PSE&G RESEARCH AND TESTING LABORATORY PROCEDURE ANALYSIS OF WATER FOR POTASSIUM 40 A 60 ml aliquot of water is acidified to pH <2 with concentrated nitric acid and then analyzed for potassium by the following Atomic Absorption Spectrophotometry method: potassium standards of known concentration (similar to that of the unknowns) are first prepared. An aliquot of each sample and standard is pipetted into stoppered flasks. In addition, a duplicate sample, ERA standard and blank water sample are likewise pipetted into their respective flasks. A solution consisting of 4% sodium is diluted 1:1 with water and then added to all the flasks.

Depending on the AA instrument used, a calibration curve is prepared from the standards after which the samples are then run.

If the absorbance of any sample is higher than the upper standard used, the sample is then either diluted and re-run, tpe burner head turned 90°, a more concentrated standard added to the calibration curve or a less sensitive wavelength used.

The results, reported in parts per million (ppm), are converted to pCi/L by means of a computer program.

Calculation of K-40 Activity:

K-40 Activity (pCi/L) = 0.8S*C 0.85 Proportionality constant for converting ppm to pCi/L C = Potassium concentration, ppm 133

SYNOPSIS OF PSE&G RESEARCH AND TESTING LABORATORY PROCEDURE ANALYSIS OF RAW MILK FOR IODINE-131 Stable iodine carrier is equilibrated in a 4-liter volume of raw milk before two separate 50ml batches of anion exchange resin are introduced to extract iodine.

After each batch has been stirred in the milk for an appropriate time, both are then transferred to an aluminum sample can where the resins are rinsed with demineralized water several times and any leftover rinsewater removed with an aspirator stick.

The can is hermetically sealed and then counted on a gamma detector.

Calculation of I-131 Activity:

I-131 Results (pCi/L) = (G-B)/T*(l.05)*(H)

(2.22)*(E)*(V)*(Y)

G = Sample gross counts B = Background counts (from blank sample)

T = Count time of sample and blank E =

Eo*EXP(-A*M) = efficiency equation where E0 = counting efficiency at zero sample thickness A = Self-absorption coefficient M

Sample thickness, mg/cm2 V = Sample volume, liters Y

Chemical recovery =

R Rl+R2 where R mg of r-recovered Rl = mg of r-carrier added R2 = mg of intrinsic stable r-measured in sample 1.05 = Correction factor for protein-bound iodine H

J/(1-K)*EXP(L) = correction factor for I-131 decay during counting period J

(0.693/8.05)*(R/1440)

R 1440

= Count time, minutes No. of minutes per day Half-life of I-131, days EXP(-J) 8.05 K

L = (0.693/8.05)*N N

134 Elapsed time (days) from mid-point of collection period to beginning of count time.

SYNOPSIS OF PSE&G RESEARCH AND TESTING LABORATORY PROCEDURE ANALYSIS OF WATER FOR TRITIUM Approximately SOml of raw sample is mixed with sodium hydroxide and potassium permanganate and is distilled under vacuum.

Eight ml of distilled sample is mixed with lOml of Instagel liquid scintillation solution, and placed in the liquid scintillation spectrometer for counting.

An internal standard is prepared by mixing Bml of sample, lOrnl of Instagel, and O.lml-0.2ml of a standard with known activity.

The efficiency is determined from this.

Also prepared is a blank consisting of Bml of distilled low-tritiated water and lOml of Instagel, to be used for a background determination.

This is done for each pair of samples to be counted.

Activity is computed as follows:

A (pCi/L) =

(G-B)*(lOOO) 2.22*(E)*(V)*(T)

Efficiency (E) is computed as follows:

E = (N)*(D)

A' N is determined as follows:

N = C-(G/T)

A = Activity B

Background count of sample G = Gross count of sample E

Counting Efficiency v = Aliquot volume (ml)

T = Count time (min) 2.22 DPM/pCi 1000 = Number of ml per L N = Net CPM of spiked sample D = Decay factor of spike A' = DPM of spike c

CPM of spiked sample G = Gross counts of sample T

Count time (min)

The associated error is expressed at 95% confidence limit, as follows:

l.96*(G/T2+B/T2)1/2*(1000) 2.22*(V)*(E)

Samples are designated LLD if the activity is less than the following value:

LLD (pCi/L)

(4.66)*(B)1/2*(1000) 2.22*(V)*(E)*(T) 135

SYNOPSIS OF CONTROLS FOR ENVIRONMENTAL POLLUTION, INC., PROCEDURE TRITIUM ANALYSIS OF AQUEOUS FRACTION OF BIOLOGICAL MATERIALS An aliquot of fish or crab flesh is placed in a round bottom flask, along with 200ml of benzene, and the water removed via azeotropic distillation.

Three milliliters of the extracted water is then mixed with aquasol cocktail (NEF-934 Aquasol cocktail, manufactured by New England Nuclear Corporation).

The resultant mixture is comprised of 19 percent sample in a clear gel-type aquasol and provides a tritium counting efficiency of approximately 30 percent, *when counted on a Beckman LS-100 Liquid Scintillation Spectrometer.

The efficiency of the counting system is determined by placing 6 tritium standards (certified by NBS) before each set of water samples to be counted.

The counting efficiency is determined from these standards which are equal in activity but vary in the amount of quenching.

All samples are counted for 500 minutes each.

136

SYNOPSIS OF PSE&G RESEARCH AND TESTING LABORATORY PROCEDURE GAMMA ANALYSIS OF AIR IODINE Approximately 300m3 of air is drawn through a SOml bed of triethylenediamine (TEDA)-impregnated charcoal granules at a rate which closely corresponds to the breathing rate of an adult male.

The contents of the exposed air iodine cartridge are emptied into an aluminum sample can containing SOml of fresh TEDA-impregnated charcoal.

The can is hermetically sealed and then counted on a gamma detector.

Calculation of Gamma Activity:

The following are the calculations performed for the gamma activity, 2-sigma error and LLD:

Result (pCi/m3)

N*D (2.22)*(E)*(A)*(T)*(V)

R N = Net counts under photopeak

  • D =Decay correction factor

.Atl*EXP(.At2) 1-EXP(-.Atl) tl Acquisition live time t2 = Elapsed time from sample

.A E

A T

v

=

=

=

collection to start of acquisition 0.693/nuclide half life Detector efficiency Gamma abundance factor (no. of photons per disintegration)

Acquisition live time, mins.

Sample volume, m3 2.22 No. of dpm per pCi 2-sigma error (pCi/m3) 1.96*(GC+BC)1/2*R N

GC Gross counts BC Background counts All other variables are as defined earlier.

The LLD (pCi/m3) =

4.66*(BC)1/2*D (2.22)*(E)*(A)*(T)*(V) 137

SYNOPSIS OF PSE&G RESEARCH AND TESTING LABORATORY PROCEDURE RADIOSTRONTIUM ANALYSIS OF AIR FILTERS The air filters are placed in a small beaker and just enough fuming nitric acid is added to cover the filters.

A blank, composed of the same number of clean air filters, is prepared in the same way.

Stable strontium carrier is then introduced into each sample and several fuming nitric acid leachings are carried out to remove the radiostrontium from the filter media.

Once this is done, the resultant nitrates are dissolved in distilled water and the filter residue is filtered out.

Radioactive interferences are stripped out by coprecipitation on ferric hydroxide (yttrium strip) followed by a barium chromate strip.

The strontium is precipitated as a carbonate, which is dried and weighed.

The samples and blank are then counted on a low background gas proportional counter and, again, at least 14 days later.

The basis for this two count method is that Sr-90 and sr-89 are both unknown quantities requiring two simultaneous equations to solve for them.

Calculation of Sr-90 Activity:

Sr-90 Results (pCi/m3) =

N4/R where S6 M

(2.22)*(E)*(E(l5)/E')*(S6)*(V)*(U)

= W2 A + B*M + C*M2 (This is the general form of the normalized Sr-90 efficiency regression equation for one particular gas proportional counter, where A, Band Care regression coefficients.)

Thickness density of strontium carbonate precipitate, mg/cm2 E(l5)/E' = Ratio of Sr-90 efficiency at thickness value of 15mg/cm2 to Sr-90 counting standard efficiency run at the time of instrument calibration (This standard is run with each group of environmental strontium samples)

E = Sr-90 counting standard efficiency V =Sample quantity (m3)

U Chemical yield N4 = (N2 - Fl*Nl)/Wl net counts due to Sr-90 only Wl = ((1 + Rl*I2) -

(1 + Rl*Il)*Fl)

Il 1 -

EXP ((-0.693/2.667)*tl)

I2 = 1 -

EXP ((-0.693/2.667)*t2) tl Elapsed time from Y-90 strip to first count 138

t2 = Elapsed time from Y-90 strip to second count 2.667 Half-life of Y-90, days Rl = D + E*M + F*M2 (This is the general form of the regression equation for Y-90 eff'y/Sr-90 eff'y ratio for one particular gas proportional counter, where D, E and F are regression coefficients.)

N2 = x*- Y, where X and Y are recount gross counts and background counts, respectively Nl = Xl - Yl, where Xl and Yl are initial gross counts and background counts, respectively 2.22 = No. of dpm per pCi Fl= EXP ((-0.693/2.667)*t2)

R = Count time of sample and blank Using the same variable definitions as above, the 2-sigma error for Sr-90 (pCi/m3) =

r;* (X+Y) +

L-w12 (Xl+Yl) *Fl211/2 w12 J (Wl*W2)

(N2-Fl*Nl)

Again, keeping the same variable definitions, the LLD for Sr-90 (pCi/m3) =

[

4.66* (X+Y) +

Wl2

( Xl+Yl) *Fl 21112 w12 -,

Calculation of Sr-89 Activity:

Sr-89 Results (pCi/m3) =

N6/R (2.22)*(E)*(E(15)/E')*(S7)*(V)*(U)*(F9)

= W3 S7 = G + H*M + I*M2 (This is the general form of the normalized Sr-89 efficiency regression equation for one particular gas proportional counter where G, Hand I are regression coefficients.)

N6 = Nl -

N7*(1 + Rl*Il)

N7 = (N2 -

Fl*Nl)/Wl (This represents counts due to Sr-90) 139

I I

E(l5)/E' = Ratio of Sr-89 efficiency at thickness value of 15mg/cm2 to Sr-90 counting standard efficiency run at the time of instrument calibration (This standard is run with each group of environmental strontium samples)

F9 =EXP ((-0.693/50.5)*t) t = Elapsed time from midpoint of collection period to time of recount for milk samples only.

For all other samples, this represents the elapsed time from sample stop date to time of recount.

50.5 = Half-life of Sr-89, days All other quantities are as previously defined.

The 2-sigma error for Sr-89 (pCi/m3) = 2

  • csa2+s92 >2
  • w3 (Nl - N7*(l+Rl*Il))

SS =UX+Y) + (Xl+Yl)*Flil1/2

[ w12 w12 J S9 = (Xl+Yl) 112

.All other variables are as previously defined.

Keeping the same variable definitions, the LLD for Sr-89 (pCi/m3) 4.66*(S82+s92)1/2 140

SYNOPSIS OF PSE&G RESEARCH AND TESTING LABORATORY PROCEDURE RADIOSTRONTIUM ANALYSIS OF RAW MILK Stable strontium carrier is first introduced into a milk sample and into a distilled water sample of equal volume to be used as a blank.

The sample(s) and blank are passed through cation resin columns which adsorb strontium, calcium, magnesium and other cations.

These cations are then eluted off with a TRIS-buffered 4N sodium chloride solution into a beaker and precipitated as carbonates.

The carbonates are converted to nitrates with 6N nitric acid and, by acidifying further to an overall concentration of 70% nitric acid, strontium is forced out of solution somewhat ahead of calcium.

Barium chromate precipitation is then performed to remove any traces of radium and radiobarium.

Strontium recrystallization is carried out, to remove residual calcium which may have been coprecipitated with the initial strontium precip-itation.

Another recrystallization removes ingrown Y-90, marking the time of the yttrium strip.

The strontium is precipitated as its carbonate, filtered, dried and weighed to determine strontium recovery.

The samples and blank are then counted on a low background gas proportional counter and, again, at least 14 days later.

The basis for this two-count method is that Sr-90 and sr-89 are both unknown quantities requiring two simultaneous equations to solve for them.

Calculation of Sr-90 Activity:

Sr-90 Results (pCi/L) =

N4/R (2.22)*(E)*(E(lS)fE')*(S6)*(V)*(U)

= W2 where S6 = A + B*M + C*M2 (This is the general form of the normalized Sr-90 efficiency regression equation for one particular gas proportional counter, where A, Band Care regression coefficients.)

M = Thickness density of strontium carbonate precipitate, mg/cm2 E(lS)/E' = Ratio of Sr-90 efficiency at thickness value of 15mg/cm2 to Sr-90 counting standard efficiency run at the time of instrument calibration (This standard is run with each group of environmental strontium samples)

E = Sr-90 counting standard efficiency V = Sample quantity (liters)

U = Chemical yield N4 (N2 -

Fl*Nl)/Wl = net counts due to Sr-90 only Wl = ((1 + Rl*I2) -

(1 + Rl*Il)*Fl)

Il = 1 -

EXP ((-0.693/2.667)*tl) i41

I2 1 -

EXP ((-0.693/2.667)*t2) tl Elapsed time from Y-90 strip to first count t2 = Elapsed time from Y-90 strip to second count 2.667 Half-life of Y-90, days Rl = D + E*M + F*M2 (This is the general form of the regression equation for Y-90 eff'y/Sr-90 eff'y ratio for one particular gas proportional counter, where D, E and F are regression coefficients.)

N2 = X -

Y, where X and Y are recount gross counts and background counts, respectively Nl = Xl - Yl, where Xl and Yl are initial gross counts and background counts, respectively 2.22 = No. of dpm per pCi Fl EXP ((-0.693/2.667)*t2)

R Count time of sample and blank Using the same variable definitions as above, the 2-sigma error for Sr-90 (pCi/L) =

~* (X+Y) +

L w12 (Xl+Yl) *Fl~ 1 /2 w12 J

  • (Wl*W2)

(N2-Fl*Nl)

Again, keeping the same variable definitions, the LLD for Sr-90 (pCi/L) =

[

4.66* (X+Y) + (Xl+Yl)*Fl2]112 w12 w12 J Calculation of Sr-89 Activity:

Sr-89 Results (pCi/L) =

N6/R (2.22)*(E)*(E(15)/E')*(S7)*(V)*(U)*(F9)

= W3 S7 G + H*M + I*M2 (This is the general form of the normalized Sr-89 efficiency regression equation for one particular gas proportional counter where G, Hand I are regression coefficients.)

N6 = Nl -

N7*(1 + Rl*Il)

N7 (N2 - Fl*Nl)/Wl (This represents counts due to Sr-90) 142

E(l5)/E' = Ratio of Sr-89 efficiency at thickness value of 15mg/cm2 to Sr-90 counting standard efficiency run at the time of instrument calibration (This standard is run with each group of environmental strontium samples)

F9 =EXP ((-0.693/50.5)*t) t = Elapsed time from midpoint of collection period to time of recount for milk samples only.

For all other samples, this represents the elapsed time from sample stop date to time of recount.

50.5 = Half-life of Sr-89, days All other quantities are as previously defined.

The 2-sigma error for Sr-89 (pCi/L) = 2* (S82+s92)1/2

  • W3 (Nl - N7*(l+Rl*Il))

SS =liX+Y) + (Xl+Yl)*Fl21/2 1=w12 w12 S9 = (Xl+Yl)1/2 All other variables are as previously defined.

Keeping the same variable definitions, the LLD for sr-89 (pCi/L) 4.66*(S82+s92)1/2 143

SYNOPSIS OF PSE&G RESEARCH AND TESTING LABORATORY PROCEDURE RADIOSTRONTIUM ANALYSIS OF WATER Stable strontium carrier is introduced into a water sample and into a distilled water sample of the same volume which is used as a blank.

The sample(s) and blank are then made alkaline and heated to near boiling before precipitating the carbonates.

The carbonates are converted to nitrates by fuming nitric acid recrystallization which acts to purify the sample of most of the calcium.

Radioactive interferences are stripped out by coprecipita-tion on ferric hydroxide (yttrium strip) followed by a barium chromate strip.

The strontium is precipitated as a carbonate before being dried and weighed.

The samples and blank are then counted on a low background gas proportional counter and, again, at least 14 days later.

The basis for this two count method is that Sr-90 and Sr-89 are both unknown quantities requiring two simultaneous equations to solve for them.

Since surface waters, as well as some drinking water samples, have been found to contain significant amounts of stable strontium, a separate aliquot from each sample is analyzed for stable strontium.

These results are used in correcting the chemical recovery of strontium to its.true value.

Calculation of Sr-90 Activity:

Sr-90 Results (pCi/L) =

N4/R (2.22)*(E)*(E(lS)fE')*(S6)*(V)*(U)

W2 where S6 = A + B*M + C*M2 (This is the general form of the normalized Sr-90 efficiency regression equation for one particular gas proportional counter, where A, Band Care regression coefficients.)

M = Thickness density of strontium carbonate precipitate, mg/cm2 E(lS)/E' = Ratio of Sr-90 efficiency at thickness value of 15mg/cm2 to Sr-90 counting standard efficiency run at the time of instrument calibration (This standard is run with each group of environmental strontium samples)

E Sr-90 counting standard efficiency V

Sample quantity (liters)

U = Chemical yield N4 = (N2 - Fl*Nl)/Wl = net counts due to sr-90 only Wl

((1 + Rl*I2) -

(1 + Rl*Il)*Fl)

Il = 1 - EXP ((-0.693/2.667)*tl) 144

/

I2 = 1 -

EXP ((-0.693/2.667)*t2) tl = Elapsed time from Y-90 strip to first count t2 = Elapsed time from Y-90 strip to second count 2.667 Half-life of Y-90, days Rl = D + E*M + F*M2 (This is the general form of the regression equation for Y-90 eff'y/Sr-90 eff 'y ratio for one particular gas proportional counter, where D, E and F are regression coefficients.)

N2 = X -

Y, where X and Y are recount gross counts and background counts, respectively Nl = Xl - Yl, where Xl and Yl are initial gross counts and background counts, respectively 2.22 = No. of dpm per pCi Fl EXP ((-0.693/2.667)*t2)

R = Count time of sample and blank Using the same variable definitions as above, the 2-sigma error for Sr-90 (pCi/L) =

[2* (X+Y) +

[

w12 (Xl+Yl)*Fl~ 1/2

  • w12 J (Wl*W2)

(N2-Fl*Nl)

Again, keeping the same variable definitions, the LLD for Sr-90 (pCi/L) =

~* 66* (X+Y) + (Xl+Yl) *Fl~ 1 /2 L w12 w12 J Calculation of sr-89 Act_ivity:

Sr-89 Results (pCi/L) =

N6/R (2.22)*(E)*(E(lS)fE')*(S7)*(V)*(U)*(F9)

= W3 S7 = G + H*M + I*M2 (This is the general form of the normalized Sr-89 efficiency regression equation for one particular gas proportional counter where G, Hand I are regression coefficients.)

N6 = Nl -

N7*(1 + Rl*Il)

N7 = (N2 - Fl*Nl)/Wl (This represents counts due to Sr-90) 145

E(lS)/E' = Ratio of Sr-89 efficiency at thickness value of 15mg/cm~+2~- to Sr-90 counting standard efficiency run at the time of instrument calibration (This standard is run with each group of environmental strontium samples)

F9 =EXP ((-0.693/50.S)*t) t = Elapsed time from midpoint of collection period to time of recount for milk samples only.

For all other samples, this represents the elapsed time from sample stop date to time of recount.

50.5 = Half-life of sr-89, days All other quantities are as previously defined.

The 2-sigma error for Sr-89 (pCi/L)

SS = lix+Y) + (Xl+Yl) *Fl~ 1 /2

[ w12 w12 J S9 = (Xl+Yl)1/2 2* (S82+s92)1/2

  • W3 (Nl - N7*(l+Rl*Il))

All other variables are as previously defined.

Keeping the same variable definitions, the LLD for sr-89 (pCi/L) =

4.66*(S82+s92)1/2 146

SYNOPSIS OF PSE&G RESEARCH AND TESTING LABORATORY PROCEDURE RADIOSTRONTIUM ANALYSIS OF VEGETATION, MEAT, CRAB SHELL AND AQUATIC SAMPLES The samples are weighed (recorded as "wet" weight) as received, before being placed in an oven to dry at 100°C.

At the completion of the drying period, samples are again weighed (recorded as "dry" weight) and then pulverized.

A measured amount (quantity dependent on desired sensitivity) of the pulverized sample is first charred over a Bunsen burner and then ashed in a muffle furnace.

The ash is fused with 40g sodium carbonate, along with 20mg strontium carrier, at 900°C for 1/2 hour.

After removal from the furnace, the melt is cooled, pulverized and added to SOOml distilled water and heated to near boiling for 30 minutes, with stirring.

The sample is filtered (filtrate discarded) and the carbonates on the filter dissolved with 1:1 nitric acid (HNo3).

The resultant nitrates are heated to dryness and are dissolved in 20ml distilled water before adding 60ml fuming HNo3.

After calcium removal with anhydrous acetone, radioactive interferences are stripped out by coprecipitation on ferric hydroxide followed by coprecipitation on barium chromate.

The strontium is precipitated as its carbonate, which is dried and weighed.

The samples are then counted on a low background gas proportional counter and, again, at least 14 days later.

The basis for this two-count method is that sr-90 and Sr-89 are both unknown quantities requiring two simultaneous equations to solve for them.

Calculation of sr-90 Activity:

Sr-90 Results (pCi/kg wet) =

N4/R (2.22)*(E)*(E(l5)/E')*(S6)*(V)*(U)

= W2 where SG = A + B*M + C*M2 (This is the general form of the normalized sr-90 efficiency regression equation for one particular gas proportional counter, where A, Band Care regression coefficients.)

M = Thickness density of strontium carbonate precipitate, mg/cm2 E(lS)/E' = Ratio of Sr-90 efficiency at thickness value of 15mg/cm2 to Sr-90 counting standard efficiency run at the time of instrument calibration (This standard is run with each group of environmental strontium samples)

E = Sr-90 counting standard efficiency V = Sample quantity (kg wet)

U = Chemical yield N4 = (N2 - Fl*Nl)/Wl = net counts due to Sr-90 only Wl = ((1 + Rl*I2) -

(1 + Rl*Il)*Fl) 147

I1 = 1 - EXP ((-0.693/2.667)*tl)

I2 = 1 - EXP ((-0.693/2.667)*t2) tl = Elapsed time from Y-90 strip to first count t2 Elapsed time from Y-90 strip to second count 2.667 = Half-life of Y-90, days Rl D + E*M + F*M2 (This is the general form of the regression equation for Y-90 eff'y/Sr-90 eff'y ratio for one particular gas proportional counter, where D, E and F are regression coefficients.)

N2 = X - Y, where X and Y are recount gross counts and background counts, respectively Nl = Xl - Yl, where Xl and Yl are initial gross counts and background counts, respectively 2.22 = No. of dpm per pCi Fl EXP ((-0.693/2.667)*t2)

R = Count time of sample and blank Using the same variable definitions as above, the 2-sigma error for Sr-90 (pCi/kg wet) =

~* (X+Y) +

[

w12 (Xl+Yl)*Fl~1/2 * (Wl*W2)

W12 J (N2-Fl*Nl)

Again, keeping the same variable definitions, the LLD for Sr-90 (pCi/kg wet) =

'-4.66* (X+Y) + (Xl+Yl)*Fl~1/2 L

w12 w12 J Calculation of Sr-89 Activity:

Sr-89 Results (pCi/kg wet) =

N6/R (2.22)*(E)*(E(lS)fE')*(S7)*(V)*(U)*(F9)

= W3 57 = G + H*M + I*M2 (This is the general form of the normalized sr-89 efficiency regression equation for one particular gas proportional counter where G, Hand I are regression coefficients.)

N6 = Nl - N7*(1 + Rl*Il) 148

N7 = (N2 -

Fl*Nl)/Wl (This represents counts due to Sr-90)

E(lS)/E' Ratio of Sr-89 efficiency at thickness value of 15mg/cm2 to Sr-90 counting standard efficiency run at the time of instrument calibration (This standard is run with each group of environmental strontium samples)

F9 EXP ((-0.693/50.S)*t) t Elapsed time from midpoint of collection period to time of recount for milk samples only.

For all other samples, this represents the elapsed time from sample stop date to time of recount.

50.5 =Half-life of Sr-89, days All other quantities are as previously defined.

The 2-sigma error for Sr-89 (pCi/kg wet) = 2* (S82+s92) 1/2

N7*(l+Rl*Il))

S8 =[cx+Y) + (Xl+Yl)*Fl;i112

[w12 w12

~I S9 = (Xl+Yl)1/2 All other variables are as previously defined.

Keeping the same variable definitions, the LLD for Sr-89 (pCi/kg wet) =

4.66*(S82+s92)1/2 149

SYNOPSIS OF PSE&G RESEARCH AND TESTING LABORATORY PROCEDURE RADIOSTRONTIUM ANALYSIS OF BONE The bone or shell is first physically separated from the rest of the sample before being broken up and boiled in 6N sodium hydroxide (NaOH) solution for a brief time to digest remaining flesh/collagen material adhering to the sample.

After multiple rinses with distilled water, the bone/shell is then oven dried and pulverized.

An aliquot of the sample is removed, weighed and ashed in a muffle furnace.

Then, in the presence of strontium carrier and cesium holdback carrier, the radiostrontium is leached out of the ash by boiling in diluted nitric acid, after which the sample is filtered.

The sample is then treated with concentrated (70%) nitric acid and boiled until strontium nitrate crystallizes out.

The strontium nitrate is freed of calcium by repeated fuming nitric acid recrystallizations.

From this point on, any radiological impurities are removed by coprecipitation with ferric hydroxide followed by coprecipitation with barium chromate.

The strontium is precipitated as strontium carbonate, which is dried, weighed, then beta-counted on a low background gas proportional counter.

A second count is performed at least 14 days later.

The basis for this two-count method is that Sr-90 and Sr-89 are both unknown quantities requiring two simultaneous equations to solve for them.

Calculation of Sr-90 Activity:

Sr-90 Results (pCi/kg dry) =

N4/R (2.22)*(E)*(E(l5)/E')*(S6)*(V)*(U)

= W2 where S6 = A + B*M + C*M2 (This is the general form of the normalized Sr-90 efficiency regression equation for one particular gas proportional counter, where A, Band care regression coefficients.)

M = Thickness density of strontium carbonate precipitate, mg/cm2 E(lS)/E' = Ratio of Sr-90 efficiency at thickness value of 15mg/cm2 to Sr-90 counting standard efficiency run at the time of instrument calibration (This standard is run with each group of environmental strontium samples)

E = sr-90 counting standard efficiency V

Sample quantity (kg dry)

U Chemical yield N4 = (N2 - Fl*Nl)/Wl = net counts due to Sr-90 only 150

Wl = ((1 + Rl*I2) - (1 + Rl*Il)*Fl)

Il 1 -

EXP ((-0.693/2.667)*tl)

I2 = 1 -

EXP ((-0.693/2.667)*t2) tl = Elapsed time from Y-90 strip to first count t2 Elapsed time from Y-90 strip to second count 2.667 = Half-life of Y-90, days Rl = D + E*M + F*M2 (This is the general form of the regression equation for Y-90 eff'y/sr-90 eff'y ratio for one particular gas proportional counter, where D, E and F are regression coefficients.)

N2 = X -

Y, where X and Y are recount gross counts and background counts, respectively Nl = Xl - Yl, where Xl and Yl are initial gross counts and background counts, respectively 2.22 = No. of dpm per pCi Fl= EXP ((-0.693/2.667)*t2)

R = Count time of sample and blank Using the same variable definitions as above, the 2-sigma error for Sr-90 (pCi/kg dry) =

[

2* (X+Y) +

w12 (Xl+Yl)*Fl~ 1 /2

  • w12 J (Wl*W2)

(N2-Fl*N1)

Again, keeping the same variable definitions, the LLD for Sr-90 (pCi/kg dry) =

~.66* (X+Y) +

[

w12 (Xl+Yl) *Flil 1 /2 w12 J Calculation of Sr-89 Activity:

Sr-89 Results (pCi/kg dry) =

N6/R (2.22)*(E)*(E(l5)fE')*(S7)*(V)*(U)*(F9)

W3 S7 = G + H*M + I*M2 (This is the general form of the normalized Sr-89 efficiency regression equation for one particular gas proportional counter where G, Hand I are regression coefficients.)

151

NG = Nl -

N7*(1 + Rl*Il)

N7 = (N2 -

Fl*Nl)/Wl (This represents counts due to Sr-90)

E(l5)/E' Ratio of Sr-89 efficiency at thickness value of 15mg/cm~+2~- to sr-90 counting standard efficiency run at the time of instrument calibration (This standard is run with each group of environmental strontium samples)

F9 =EXP ((-0.693/50.5)*t) t = Elapsed time from midpoint of collection period to time of recount for milk samples only.

For all other samples, this represents the elapsed time from sample stop date to time of recount.

50.5 = Half-life of Sr-89, days All other quantities are as previously defined.

The 2-sigma error for Sr-89 (pCi/kg dry) = 2* (S82+s92)1/2

N7*(l+Rl*Il))

SB =lcX+Y) + (Xl+Yl)*Fl~1/2 t.=w12 w12

=1 59 = (Xl+Y1) 1/2 All other variables are as previously defined.

Keeping the same variable definitions, the LLD for Sr-89 (pCi/kg dry) =

4.66*(S82+s92) 11 2 152

SYNOPSIS OF PSE&G RESEARCH AND TESTING LABORATORY PROCEDURE RADIOSTRONTIUM ANALYSIS OF SOIL AND SEDIMENT After the soil or sediment sample has been dried and pulverized, a SOgm aliquot is added to approximately 1/3 - liter concentrated hydrochloric acid (HCl), containing Sml of strontium carrier (lOmg sr++/ml).

A blank con-taining only 1/3 - liter concentrated HCl and Sml strontium carrier is run in parallel with the sample.

The samples are stirred vigorously for at least 30 minutes and then filtered.

The filtrate is then diluted to a known volume and aliquots removed for stable strontium.

The remaining sample is alkalinized with ammonium hydroxide to precipitate all the transitional elements.

After filtering out these interferences, the filtrate is heated and sodium carbonate added to precipitate strontium and calcium carbonate.

These carbonates are first filtered and then digested with 6N HNo3.

Two fuming (90%) HNo3 recrystallizations are then performed to remove calcium.

Subsequently, radioactive impurities are removed by two precipitation steps, using ferric hydroxide and barium chromate as carriers.

The strontium is precipitated as strontium carbonate before being dried and weighed.

The samples are counted for beta activity in a low background gas proportional counter (Count time will vary, depending on th~ desired sensitivity.).

There is a second count at least 14 days later.

The basis for this two-count method is that sr-90 and Sr-89 are both unknown quantities requiring two simultaneous equations to solve for them.

Calculation of sr-90 Activity:

Sr-90 Results (pCi/kg dry) =

N4/R (2.22)*(E)*(E(l5)/E')*(S6)*(V)*(U)

= W2 where S6 = A + B*M + C*M2 (This is the general.form of the normalized Sr-90 efficiency regression equation for one particular gas proportional counter, where A, Band care regression coefficients.)

M = Thickness density of strontium carbonate precipitate, mg/cm2 E(lS)/E' =Ratio of Sr-90 efficiency at thickness value of 15mg/cm2 to Sr-90 counting standard efficiency run at the time of instrument calibration (This standard is run with each group of environmental strontium samples)

E = Sr-90 counting standard efficiency v

Sample quantity (kg dry) u = Chemical yield N4 = (N2 - Fl*Nl)/Wl = net counts due to Sr-90 only Wl = ((1 + Rl*I2) - (1 + Rl*Il)*Fl) 153

Il = 1 - EXP ((-0.693/2.667)*tl)

I2 = 1 -

EXP ((-0.693/2.667)*t2) tl Elapsed time from Y-90 strip to first count t2 Elapsed time from Y-90 strip to second count 2.667 = Half-life of Y-90, days Rl D + E*M + F*M2 (This is the general form of the regression equation for Y-90 eff'y/Sr-90 eff'y ratio for one particular gas proportional counter, where D, E and F are regression coefficients.)

N2 X -

Y, where X and Y are recount gross counts and background counts, respectively Nl = Xl - Yl, where Xl and Yl are initial gross counts and background counts, respectively 2.22 = No. of dpm per pCi Fl EXP ((-0.693/2.667)*t2)

R = Count time of sample and blank Using the same variable definitions as above, the 2-sigma error for sr-90 (pCi/kg dry) l.2* (X+Y) +

L w12 (Xl+Yl') *Fl~ 1 /2

  • w12 J (Wl*W2)

(N2-Fl*Nl)

Again, keeping the same variable definitions, the LLD for Sr-90 (pCi/kg dry) =

~.66* (X+Y)

[

w12

+ (Xl+Yl)*Fl~1/2 w12 J Calculation of Sr-89 Activity:

Sr-89 Results (pCi/kg dry) =

N6/R (2.22)*(E)*(E(l5)/E')*(S7)*(V)*(U)*(F9)

W3 57 G + H*M + I*M2 (This is the general form of the normalized Sr-89 efficiency regression equation for one particular gas proportional counter where G, Hand I are regression coefficients.)

N6 = Nl -

N7*(1 + Rl*Il) 154

N7 = (N2 -

Fl*Nl)/Wl (This represents counts due to Sr-90)

E(l5)/E' = Ratio of Sr-89 efficiency at thickness value of 15mg/cm2 to Sr-90 counting standard efficiency run at the time of instrument calibration (This standard is run with each group of environmental strontium samples)

F9 =EXP ((-0.693/50.5)*t) t = Elapsed time from midpoint of collection period to time of recount for milk samples only.

For all other samples, this represents the elapsed time from sample stop date to time of recount.

50.5 = Half-life of sr-89, days All other quantities are as previously defined.

The 2-sigma error for Sr-89 (pCi/kg dry) = 2* (S82+s92)1/2

N7*(l+Rl*Il))

SS = lix+Y) + (Xl+Yl) *Fl~ 1 /2 L

w12 w12 J S9 = (Xl+Yl) 1 /2 All other variables are as previously defined.

Keeping the same variable definitions, the LLD for Sr-89 (pCi/kg dry) =

4.66*(S82+s92)1/2 155

SYNOPSIS OF PSE&G RESEARCH AND TESTING LABORATORY PROCEDURE ANALYSIS OF ENVIRONMENTAL SAMPLES FOR STABLE STRONTIUM It has been the practice of the Chemical/Environmental Division to perform a stable strontium determination on any samples to be analyzed for strontium 90 and 89, if they are likely to contain significant amounts of the stable isotopes.

In the case of mineral (soil or sediment) or biological (bone and shell) media, an ashing and/or acid leaching is performed to extract the element of interest.

The removal of the aliquot is done early in the course of the radiostrontium analysis and involves the withdraw! of 25 ml of diluted leachate (soil and sediment only) from the regular sample, transferring it to a flask.

Bone and shell are prepared by ashing 2 g of sample, digesting in 6N HCl, filtering out insoluble residues and then transferring to a flask.

All the above samples are analyzed by the method of Standard Additions, whereby each sample leachate is spiked with known concentrations of stable strontium. The sample, spiked samples and blank are determined by Atomic Absorption Spectroscopy (AAS) or Atomic Emission Spect~oscopy (AES) and are plotted graphically.

The true concentration is then extrapolated.

Chemical and ionization interferences are controlled by adding 1% or more of lanthanum as chloride to all samples to be analyzed.

For analysis of water, a 60-ml aliquot of sample is removed, acidified to pH

<2 with hydrochloric or Nitric acid and analyzed by AAS or AES as follows: A group of strontium standards (of similar concentration to the unknowns) is prepared.

Then, to 9 ml of each prepared sample, blank and standard, is added 1 ml of lanthanum oxide solution.

All results (calculated as milligrams of strontium per liter) are then used to find the true chemical recovery of strontium based on both the amount of carrier added (only in the case of soil and sediment) and the quantity of strontium intrinsic to the sample.

Sample Calculation of Corrected Chemical Recovery of Strontium in Soil and Sediment:

Reported concentration of stable strontium (mg/L):l19 Volume of specimen (ml):25 (removed from lOOOml of diluted leachate)

Proportion of sample used for aliquot: 0.025 Milligrams strontium in 25ml flask (119mg/L) x (.025L/25ml) x (25ml)

2.98mg Sr Since 2.98mg Sr represents the quantity of stable strontium in 2 1/2 percent of the sample, total strontium (stable + carrier) in the full sample

2.98mg Sr

= 119 mg 0.025 156

  • Net weight of srco3 precipitate (mg): 125 Percent of Sr in precipitate: 59.35 Quantity of strontium recovered= (125mg) x (.5935) = 74.2 Corrected chemical recovery of strontium =

74.2 = 0.623 119.0 The calculations follow the same sequence for bone and shell samples.

Sample Calculation of Corrected Chemical Recovery of Strontium in Water:

Reported concentrations of stable strontium (mg/L): 1.65 Volume of radiochemical water sample (liters): 2.0 Stable strontium in 2 liter sample (l.65mg/L) x (2.0L) 3.30mg Quantity of strontium carrier added to sample (mg): 20.0 Total amount of strontium in sample (mg): 20.0 + 3.30 = 23.3mg Net weight of Srco3 precipitate (mg): 28.9 Percent of Sr in precipitate: 59.35 Quantity of strontium recovered= (28.9mg) x (.5935) = 17.2mg Corrected chemical recovery of strontium= 17.2mg =.738 23.3mg 157

SYNOPSIS OF PSE&G RESEARCH AND TESTING LABORATORY PROCEDURE GAMMA ANALYSIS OF AIR PARTICULATE COMPOSITES At the end of each calendar quarter, 13 weekly air filters from a given location are stacked in a two inch diameter Petri dish in chronological order, with the oldest filter at the bottom, nearest the detector, and the newest one on top.

The Petri dish is closed and the sample counted on a gamma detector.

The following are the calculations performed for the gamma activity, 2-sigma error and LLD:

Result (pCi/m3) =

N*D

= R (2.22)*(E)*(A)*(T)*(V) 2-sigma error (pCi/m3)

N = Net counts under photopeak D = Decay correction factor Atl*EXP(At2) 1-EXP(-Atl) tl = Acquisition live time t2 Elapsed time from sample collection to start of acquisition A

0.693/nuclide half life E

Detector efficiency A

Gamma abundance factor (no. of photons per disintegration)

T = Acquisition live time, mins.

V = Sample volume, m3 2.22 = No. of dpm per pCi l.96*(GC+BC)1/2*R N

GC = Gross counts BC Background counts All other variables are as defined earlier.

The LLD (pCi/m3) =

4.66*(BC)1/2*D (2.22)*(E)*(A)*(T)*(V) 158

SYNOPSIS OF PSE&G RESEARCH AND TESTING LABORATORY PROCEDURE GAMMA ANALYSIS OF RAW MILK A well mixed 3.~-liter sample of raw milk is poured into a calibrated Marinelli beaker along with 20ml of 37% formaldehyde solution (used as a preservative).

After stirring, the sample is brought to ambient temperature and then counted on a gamma detector.

Calculation of Gamma Activity:

The following are the calculations performed for the gamma activity, 2-sigma error and LLD:

Result (pCi/L) =

N*D

= R (2.22)*(E)*(A)*(T)*(V)

N = Net counts under photopeak D = Decay correction factor tl =

t2 =

A =

E =

A =

A tl*EXP(At2) 1-EXP(-Atl)

Acquisition live time Elapsed time from sample collec-tion to start of acquisition 0.693/nuclide half life Detector efficiency Gamma abundance factor (no. of photons per disintegration)

T = Acquisition live time, mins.

V = Sample volume, liters 2.22 = No. of dpm per pCi 2-sigma error (pCi/L) = 1.96*(GC+BC)1/2*R N

GC = Gross counts BC = Background counts All other variables are as defined earlier.

The LLD (pCi/L) =

4.66*(BC)1/2*D (2.22)*(E)*(A)*(T)*(V) 159

SYNOPSIS OF PSE&G RESEARCH AND TESTING LABORATORY PROCEDURE GAMMA ANALYSIS OF WATER After thoroughly agitating the sample container, 3.5 liters of water sample is poured into a calibrated Marinelli beaker and then counted on a gamma detector.

Calculation of Gamma Activity:

The following are the calculations performed for the gamma activity, 2-sigma error and LLD:

Result (pCi/L) =

N*D

= R (2.22)*(E)*(A)*(T)*(V)

N = Net counts under photopeak D = Decay correction factor tl =

t2 =

A =

E A =

Atl*EXP(At2) 1-EXP(-Atl)

Acquisition live time Elapsed time from sample collec-tion to start of acquisition 0.693/nuclide half life Detector efficiency Gamma abundance factor (no. of photons per disintegration)

T Acquisition live time, mins.

V = Sample volume, liters 2.22 = No. of dpm per pCi 2-sigma error (pCi/L) = 1.96*(GC+BC)1/2*R N

GC = Gross counts BC = Background counts All other variables are as defined earlier.

The LLD (pCi/L) =

4.66*(BC)1/2*D (2.22)*(E)*(A)*(T)*(V) 160

SYNOPSIS OF PSE&G RESEARCH AND TESTING LABORATORY PROCEDURE GAMMA ANALYSIS OF SOLIDS Several methods are employed in preparing solids for gamma analysis, depending on the type of sample or sensitivity required.

For high sensitivity analysis of vegetation, meat and seafood, the sample is first weighed,.then oven-dried to a constant weight.

A ratio of wet-to-dry weight is computed before the sample is ground and compressed to unit density (lg/cm3), when possible, in a tared aluminum can.

The can is weighed, hermetically sealed and counted.

In most cases, a wet sample is prepared (when a lower sensitivity is acceptable) by either grinding/chopping the wet sample or.by using a food processor to puree it.

The sample is poured into a calibrated, tared clear plastic container, aluminum can, or marinelli beaker until a standard volume is reached for that container.

The sample is weighed, sealed, and counted.

Soil and sediment samples are first oven dried until a constant weight is achieved and then pulverized.

The sample is added to a tared aluminum can, compacted to a standard volume and weighed.

It is hermetically sealed, cured for 30 days to allow for ingrowth, and counted.

Calculation of Gamma Activity:

The following are the calculations performed for the gamma activity, 2-sigma error and LLD:

Result (pCi/kg)

N*D R

(2.22)*(E)*(A)*(T)*(V)

N = Net counts under photopeak D = Decay correction factor Atl*EXP(At2) 1-EXP(-Atl) tl = Acquisition live time t2 = Elapsed time from sample collec-tion to start of acquisition A = 0.693/nuclide half life E = Detector efficiency A = Gamma abundance factor (no. of photons per disintegration)

T = Acquisition live time, mins.

= Sample volume, kilograms v

2.22 No. of dpm per pCi 2-sigma error (pCi/kg) = 1.96*(GC+BC)1/2*R N

GC = Gross counts BC = Background counts All other variables are as defined earlier.

The LLD (pCi/kg) =

4.66*(BC)1/2*D (2.22)*(E)*(A)*(T)*(V) 161

SYNOPSIS OF TELEDYNE ISOTOPES PROCEDURE ANALYSIS OF TELEDYNE ISOTOPES THERMOLUMINESCENT DOSIMETERS I

These devices are rectangular Teflon wafers impregnated with 25% caso4 :Dy phosphor.

They are first annealed in a 2S0°c oven prior to exposure in the field.

Following field exposure (for a 1-month or 3-month period) four separate areas of the dosimeter are read in a Teledyne Isotopes model 8300 TLD reader.

The dosimeter is then re-irradiated by a standardized Cs-137 source and the four areas are read again.

Calculation of the environmental exposure is performed by computer, using the re-irradiation readings to determine the sensitivity of each area of the dosimeter.

The readings of control dosimeters are subtracted to allow for transit dose and system back-ground.

The results are computed as follows:

For any given area of the dosimeter, the dose in mR is calculated by the following formula:

DOSE = R * (REDOSE/RR)-AVC R = Initial reading of the area RR = Second reading of the area (after re-irradiation)

REDO SE = Re-irradiation dose, mR AVC = Average of control values, 4N where AVC =

~CDOSE/4N i=l mR N = Total number of control dosi-meters CDOSE = CR*(CREDOSE/CRR)

CDOSE = Control area dose, mR CR = Initial reading of control area CRR = Second reading of the control area (after re-irradiation)

CREDOSE = Re-irradiation dose of the control dosimeter, mR 162

APPENDIX E

SUMMARY

OF USEPA ENVIRONrdENTAL RADIOACTIVITY LABORATORY INTERCOI\\.'.IPARISON STUDIES PROGRAM RESULTS 163

APPENDIX E

SUMMARY

OF USEPA INTERCOMPARISON STUDIES PROGRAM Appendix E presents a summary of the analytical results for the 1990 USEPA Environmental Radioactivity Laboratory Intercomparison Studies Program.

TABLE NO.

E-1 TABLE OF CONTENTS TABLE DESCRIPTION Gross Alpha and Gross Beta Emitters in Water and Air Particulates.................................

E-2 Gamma Emitters in Milk, Water, Air Particulates PAGE 166 and Food Products................................

16 7 E-3 E-4 E-5 Tritium in Water.................................

Iodine in Water.................................

  • Strontium-89 and Strontium-90 in Air Particulates, Milk, Water and Food Products *.*****....*.**.....

165 168 169 170

TABLE E-1 USEPA ENVIRONMENTAL RADIOACTIVITY LABORATORY INTERCOMPARISON STUDY PROGRAM DATE MM-YY 01-90 03-90 04-90 05-90 08-90 09-90 10-90 Gross Alpha and Gross Beta Analysis of Water (pCi/L) and Air Particulate (pCi/filter)

PSE&G ENV SAMPLE CODE MEDIUM ANALYSIS Mean +/- s.d.

EPA-WAT-AB299 Water Alpha 13+/-1.5 Beta 15+/-0.4 EPA-APT-GABS303 APT Alpha 7+/-1.0 Beta 30+/-0.8 EPA-WAT-P304 Water Alpha 99+/-4.2 Beta 56+/-1. 4 EPA-WAT-AB307 Water Alpha 21+/-1.9 Beta 17+/-0.9 EPA-APT-GABS311 APT Alpha 14+/-0.3 Beta 62+/-1.2 EPA-WAT-AB313 Water Alpha 14+/-1.2 Beta 12+/-1.0 EPA-WAT-P317 Water Alpha 82+/-3.7 Beta 56+/-0.8

  • s.d. -

one standard deviation of three individual analytical results

    • known value with control limits, indicating whether results are in agreement or disagreement 166 EPA Known 12+/-5 12+/-5 5+/-5 31+/-5 90+/-23 52+/-5 22+/-6 15+/-5 10+/-5 62+/-5 10+/-5 10+/-5 62+/-16 53+/-5

TABLE E-2 USEPA ENVIRONMENTAL RADIOACTIVITY LABORATORY INTERCOMPARISON STUDY PROGRAM DATE MM-YY 02-90 03-90 04-90 04-90 08-90 09-90 10-90 10-90 Gamma Analysis of Milk, Water (pCi/L), Air Particulate (pCi/filter) and Food Products (pei/kg)

ENV SAMPLE CODE MEDIUM EPA-WAT-G300 Water EPA-APT-GABS303 APT EPA-WAT-P304 Water EPA-MLK-GS305 Milk EPA-WAT-G308 water EPA-APT-GABS311 APT EPA-MLK-GS314 MLK EPA-WAT-G315 water EPA-WAT-P317 water ANALYSIS Ba-133 Co-60 Zn-65 Ru-106 Cs-134 Cs-137 Cs-137 Cs-134 cs-137 Cs-137 K(l)

I-131 Co-60

Ba-133 Co-60 Zn-65 Ru-106 Cs-134 Cs-137 Cs-134 cs-137 PSE&G Mean +/- s.d.

79+/-5.7 16+/-0.5 142+/-6.2 141+/-7. 8 20+/-0.9 20+/-1. 7 10+/-0.5 16+/-1.9 16+/-0.9 26+/-0.6 1560+/-52 101+/-1.2 27+/-2.9 153+/-5.8 204+/-1.2 26+/-2.9 27+/-1.2 99+/-3.4 23+/-1.1 60+/-1.2 21+/-0.5 1750+/-29 121+/-4.8 22+/-1.6 117+/-0.9 153+/-8.2 13+/-0.5 13+/-1.0 8+/-0.8 7+/-1.0 (1) Reported as mg/l of Potassium EPA Known 74+/-7 15+/-5 139+/-14 139+/-14 18+/-5 18+/-5 10+/-5 15+/-5 15+/-5 24+/-5 1550+/-78 99+/-10 24+/-5 148+/-15 210+/-21 24+/-5 25+/-5 99+/-10 20+/-5 58+/-6 20+/-5 1700+/-85 110+/-11 20+/-5 115+/-12 151+/-15 12+/-5 12+/-5 7+/-5 5+/-5

  • s.d. -

one standard deviation of three individual analytical results

    • known value with control limits, indicating whether results are in agreement or disagreement 167

TABLE E-3 USEPA ENVIRONMENTAL RADIOACTIVITY LABORATORY INTERCOMPARISON STUDY PROGRAM DATE MM-YY 02-90 06-90 10-90 Tritium Analysis of Water (pCi/L)

ENV SAMPLE CODE MEDIUM ANALYSIS EPA-WAT-H302 Water H-3 EPA-WAT-H309 water H-3 EPA-WAT-H316 Water H-3 PSE&G Mean +/- s.d.

5130+/-59 3250+/-76 8330+/-190 EPA Known 4980+/-500 2930+/-360 7200+/-720

  • s.d. - one standard deviation of three individual analytical results
    • known value with control limits, indicating whether results are in agreement or disagreement 168

TABLE E-4 USEPA ENVIRONMENTAL RADIOACTIVITY LABORATORY INTERCOMPARISON STUDY PROGRAM Iodine Analysis of Water (pCi/L)

DATE MM-YY 02-90 08-90 ENV SAMPLE CODE EPA-WAT-I301 EPA-WAT-I310 (1) Analysis cancelled by EPA MEDIUM ANALYSIS Water I-131 Water I-131 PSE&G Mean +/- s.d.

( 1) 37+/-1.4

  • s.d. - one standard deviation of three individual analytical results
    • known value with control limits, indicating whether results are in agreement or disagreement 169 EPA Known (1) 39+/-6

TABLE E-5 USEPA ENVIRONMENTAL RADIOACTIVITY LABORATORY INTERCOMPARISON STUDY PROGRAM Strontium-89 and strontium-90 Analysis of Air Particulates (pCi/filter),

Milk, Water (pCi/L) and Food Products (pCi/kg)

DATE PSE&G EPA MM-YY ENV SAMPLE CODE MEDIUM ANALYSIS Mean +/- s.d.

Known 01-90 EPA-WAT-S298 Water Sr-89 23+/-1.6 25+/-5 Sr-90 19+/-0.6 20+/-1. 5 03-90 EPA-APT-GABS303 APT Sr-90 11+/-0.5 10+/-1.5 04-90 EPA-WAT-P304

. Water Sr-89 9+/-1.4 10+/-5 Sr-90 10+/-1.2 10+/-1.5 04-90 EPA-MLK-GS305 Milk Sr-89 23+/-2 23+/-5 sr-90 26+/-0.7 23+/-5 05-90 EPA-WAT-S306 Water Sr-89 8+/-1.1 7+/-5 Sr-90 7+/-0.8 7+/-5 08-90 EPA-WAT-GABS311 APT Sr-90 19+/-0.6 20+/-5 09-90 EPA-WAT-5312 Water Sr-89 9+/-1.2 10+/-5 Sr-90 10+/-1.2 9+/-5 09-90 EPA-MLK-GS314 Milk Sr-89 16+/-1.2 16+/-5 Sr-90 19+/-0.9 20+/-5 10-90 EPA-WAT-P317 Water Sr-89 20+/-1.0 20+/-5 Sr-90 15+/-1.0 15+/-5

  • s.d. -

one standard deviation of three individual analytical results

    • known value with control limits, indicating whether results are in agreement or disagreement 170

tlt sns~ ~sn CINV'1 ao SIScIONXS

\\

.)

APPENDIX F SYNOPSIS OF 1990 LAND USE CENSUS A land use census was conducted to identify, within a distance of 8 km (5 miles), the location of the nearest milk animal, the nearest residence and the nearest garden of greater than 50m2 (500ft2) producing broad leaf vegetation in each of the 16 meteorological sectors.

Tabulated below are the results of these surveys:

Milk Nearest Vegetable Animal Residence Garden Meteorological Sept., 1990 Sept/Oct 1990 Sept/Oct 1990 Sector km (miles) km (miles) km (miles)

N None None None NNE None 6.9 (4.3)

None NE None 6.4 ( 4. 0)

None ENE None 5.8 (3. 6)

None E

None 5.4 ( 3. 4)

None ESE None None None SE None None None SSE None None None s

None 6.6 ( 4.1)

None SSW None 5.5 (3.4)

None SW None 6.9 (4.3)

None WSW None 7.1 (4.4)

None w

7.8 ( 4. 9) 6.5 ( 4. 0)

None WNW None 5.5 (3.4)

None NW None 5.9 (3.7)

None NNW None 6.8 (4.2)

None 173