I 7.. *'"form APF-05-003-01, Rev. O in i,:)

i*l C.1.

ASSIGNED DISCIPLINE:

MECHANICAL DESIGN DOCUMENT CHANGE NOTICE DOCUMENT NUMBER 10466-A-1701 OTHER DOCUMENTS AFFECTED BY THIS CHANGE:

10466-A-1702 OTHER DDCN'S REQUIRED TO IMPLEMENT CHANGE:

10466-A-1702-05-01 REASON FOR CHANGE:

Correct Radiation Monitor location discrepancies found in PIR 2003-2830.

DESCRIPTION OF CHANGE:

INITIATING DOC.

TYPE: PIR NO. 2003-2830 DCP/CCP NO NIA REV.

REV.

05 SEQ.NO.

01 PAGE I OF I Drawing 10466-A-1701 shall be revised to remove the incorrectly located S030 area radiation monitor as shown in th1 attached mark.up. Per J-14SD99 and field walkdowns, area radiation monitor S030 is located in the Hot Instrument Shop and should be shown on drawing 10466-A-1702.

RELEASE AS DDCN FOR REVISION PREPARED BY:

DESIGN VERIFIED BY:

APPROVED BY:

DOCUMENT CONTROL RELEASE:

DA TE:

1 1/06/03 DATE: (l*/f-OJ DATE:~

DATE: //7/0'{-

L' 0

D

\\

~+-

Q[jLN fi. I O"l (.L - A - r:10{ -o~ -ol ArrA:UHY\\ENi.1.

Pf\\fs-t l c~ I

USAR FIG.-12.3-2-01 ESSENTIAL DRAWING

H

\\

0

\\.fa Form APF-05-003-01, Rev. 0 ASSIGNED DISCIPLINE:

MECHANICAL DESIGN DOCUMENT CHANGE NOTICE DOCUMENT NUMBER 10466-A-1702 OTHER DOCUMENTS AFFECTED BY THIS CHANGE:

I 0466-A-l 701 OTHER DDCN'S REQUIRED TO IMPLEMENT CHANGE:

l 0466-A-I701-05-0 I REASON FOR CHANGE:

Correct Radiation Monitor location discrepancies found in PIR 2003-2830.

DESCRIPTION OF CHANGE:

INITIATING DOC.

TYPE: PIR NO. 2003-2830 DCP/CCP NO NIA REV.

REV.

SEQ. NO.

05 01 PAGE 1 OF I Drawing 10466-A-1702 shall be revised to correctly locate area radiation monitors SD30 & S04 7 as shown in the attached markups.

Drawing J-14SD99, Sh. 6, indicates that SD30 is located on the 2000' elevation in room 1334, Hot Instrument Shop.

This corresponds to its description in NPIS, MPAC, Spec J-362, and the TPSD. According to the same source, J-14SD99, SD47 is located on the 2000' elevation at 8' east of column line AN and 1' north of column line A5. This puts it in the PASS sampling room. This also corresponds to the descriptions in NPIS, MPAC, Spec J-362, and the TPSD.

Both area radiation monitors, SD30 & S047, should be shown on drawing 10466-A-1702.

RELEASE AS DOCN FOR REVISION PREPARED BY:

DATE:

11/06/03 DESIGN VERIFIED BY:

DATE: ll: 'l"°'l APPROVED BY:

DATE: Jt/1)~

DOCUMENT CONTROL RELEASE:

lX 3(

DATE:

1/7/otj

AHo.c.h~-t.i nDc.N IO'tG,<..-A-1~1.- OS'-01 P~e..

I <*2

l D

[11 rru

Ji 0

+*

\\

D A-~a.ch ""4.,J j_

fl OlN I 04C.<.-A-- 17-02 -OS"- OJ Pa..9t. 2 ~ 2

L Rlfl RMWJIIN IWIIIIBOl.l.I IENEKAL NME&. IEE D"6 NO.A-01DI.

t. NEA wtLL. IE Hl6Jffft :DIM: ONLY IF IENlflDMT Pftl'MARY TO SEOONMR\\' trrEAM tiENERATal I.EAKMlf J. JHE flWST a £IPECJED TU HAVE A MAJUMlld ~ACT DOBE llf I..E8S 'DWI ID IIREM#HOOII WHEII THE WMER B PETURNED FRCM THI: REFUElJN& PUDL. THUi IIILL IE RAPIDLY REDUCED BY Pf1DDE861N& 1HJ1D16H lHE HNI' fllfl. RX1. PllbACmON FILTElt la'IINERAUZat.

H E

D C

B;

!e

!~

,8

! ~

USAR FIG. 12.3-2-02

, ~

~---E-S_S_E_N_T_I_A_L_D_R_A_W_I_N_G ___ -+-,!]

!~

![l 1.9

!]

e----Wl/-*----CRILCCCACCIFDCCl'-'ei'e'Tl/f.cc_lO"'ll:;"-CNl!:;~IKCCZ~O~N~E=s-'1,_'~_;,_~_~L_,c----j A : I NORMAL OPERATION I 8 EL.2000'-0"

!s i]

!~

,~

10466-A-1702 06

NOTES I.

FOR RADIATION 6YM80UI I 61!'NERAl NIJl'ES, SEE DW6 NO. A-G701,

2. AREi\\ WILL BE A. Hll!RER ?Q,IE; WHEN SPENT FUEL 15 BflNS TIWIIFERRED IN 1llE SPENT Ra F'ODL CL08E TO 'TlllS AREA 6 FROM FUEL SHll'f'INB QMH OllfllN8 WASHOIWN.

9, ACTUAL D06E9 BISTINS INSIDE CONTAINMBn' AT EL 20281.on MAY Bf LOWEft ~

ZDNE E. n!E ACTUAL. LEVELB COULO SE DETERMINED FROM A RAD1AT10NSU~.

RADIATION ZONES-NORMAL OPERATION EL. 2026'-0" Y,o"-1'-0" 10466-A-1703 04 H

F D

USAR FIG. 12.3-2-04 ESSENTIAL DRAWING

Contmllod-llmllod o_.,..,40ht/wl<

C.ntroll..t....,s.llm1ml o..,._oybatwHn6-40ht/wk C."""llod-llmilod i.e'i;.,..:'"",,_.ponad,;

ur-ttallodAcnnAnlu*Arwnlrmdothoplant*tN-ln;na

,nd-byplonl......,_*lldlri1i1Gn.. n<Jlund*tfMldl"""

--:*~::::"m=' =:: :; ;::,.-;:si:;; :::::=

c.,....,llod-A-*Tholo-*v,rilhln1ho-buundwyof

=~~1::::::;::r~l~.:::

o111,op1-,.m.1......i.buoll,,_..,..,.,--,.1.....,

..=.*~~':~.' d.....,,upom-,,nd a,lllor-an by O"""""""'*Th*fuw.,..ntl,f..,lnfulduallna_...,Jo,-.F.,..

ZonmC.Eooou-i,n,bo"-mlnodon,n.,.byatN.ond lndlvulwllbyindlVldualballlbylhopl.,.h*llll~vlicsmll'.

THEsrEAM CONDENSATE

-TO-USAR FIG. 12.3-2-05 ESSENTIAL DRAWING IE>ISll>INJTU, 1SSUEDPERAP05*0IO,SECTION610,TAl3LE'"A'".TYPE8

8 7

6 5

2 1

N USAR FIG. 12.3-2-06 ESSENTIAL DRAWING

© REVISED INCORPORATED CHANGE 09883 CHG. DOC.

Q ISSUED fH[S OWG. SI.IPERSEOED BY RH.

TH[5 OIi~. SUPERSEDES REVISION NOTES, REVISED TO REFLECT AS BUil T INFORMATION

~* [L~ ©lRi~~~

~JUCLEAR OPERA TING CORPORATION PKG. ~JO.

REV.

ELECTRONIC APPROVAL RADIATION ZONES FOR NORMAL OPERATION TURBINE BUILDING EL.2033'-0" & EL.2065'-0" SCALE DRAWING NUMBER SHEET 11 "1'0"

/ 16

=

10466-A-1706 05 34X44 [ SIZ[

H G

F E

D C

B A

PS(- ________ _

00 0

i=:::

0

REACTOR MAl<E -

UP WATER L

M-12BL01 >7------~::~

( C-2>

BLV0059 BL-053-HCD-2 001 -HC0-2 001-HC0-2 002-HCO-2 ---i---[:}-------,~t--] I C 01 u

0 N

Z V0048

~

~

/,r,-' 1

/

7

/ 7

/ 7 j,,' ~¥ff?

008-HC0-1

~

~

/

/

/

/

/:

I W

I

/, // / / '

I

/

/

/"A h1Ai,/ // // 003-, D 1,,/ I)(

I// '}l_

STE~

/

,!_ ~8_1 _ ><_B_EJ~'.:,, /

/'... \\,.{ \\

- __.:M.:,-c::..::2:.._F B::0;L..../ /

/

  • , /

lcH-l"

/

I

, /IV0001

'V

/'

/

/

I

/

/

/

/

/

/

1/

/

""*-~--*--, /

/1

/

'""'~R*.A"I~,. ~. '(

1*.....

/:

/

r r

1V1 I'" r 1\\.1 1 1

/

J,-,-.- OF -C'['="'/I c~- 1

~ w; II 1....-

1"'{

/

SEE NOTE 9,

' '- /

/

M "

u N

I W

+/- -

I/\\

A,UXI LI ARY BLOG.

VENT! LATI ON M-12GL03 C F - 51

~--------"

2 NPT V0052. I 035-HC0-2 -~

BL! NO

~

z

':1'

~

Sz D-W <C a:

a, D a:

0 0 -'

~

' ' ' ' ' ' v ORW 041-HCO-l 020-HBD-l/2 \\

0 m I_\\

l~

D >-

w _J N

CJ) CL.

(S) rfl CL.

<I w :)

'Y I'-

ll: U)

(\\J 1

~

w Lee 0

~~

E u"

I\\

3/4 X 1/2 OVERFLOW DRAIN NORMAL DRAIN WCNOC 00 SPRAY BOOTH

! SHD04 !


~

VENDOR 3/4( Vl n

HVAC INLET

<ATMOS.>

007-HCD 004-HCD-2 V0004 005-HCD-2

. ~

V0005 NOTE 5 (TYPICAL 4 PLP1CESl (HI5j

  • 0009

'-,-/

M 0012

'-,-/

M-1 2H001 021 -HC0-2 C 0- 6)

HEATER

~--------:

_(His'\\ *


0----- ~

WC NOC VENDOR NOTE 2

,- ---------------,l_._._,J_f----------------~------:()+:---------------.

1

~

V01 02

[-

I I

I

  • I

( HI s '

  • r- - - - r -

- - - ~

ULTRA ~

~

--i-,--


i---.

TRANS.

00098:

YS

  • 11 I

I

'-._./

1 I

I L __ L 0004

'1-----+

L __ L '._ __ __.

TANK : __ N9~E- ! _____... :

/:

314 FILTERS FHD0r::] *

~I _F_H_D_0_8~I

  • F F

FAN

~

'-I _Cc.....H-=0_01~1 ~

u I

6b 0010 THD02A !

---+,-<->'+-,-----i--~

\\I PUMP PHD02A !

r,*

I X l/4---/1_j 1, 1*1 J

_/ V0024 L

I NOTE 4

--=~

@+*--.. ---

! SHD05 ]

ULTRASONIC GENERATOR SHD02A !

: SMALL DECON.

TANK A

-~ -

Q~

1 1 /2 VENDOR V0010 WCNOC 022-HC0-1 009-HCD-1 1 /2

'--.-H*.i*'-]

023-HC0-1 _Jy~;25 WCNOC ----r VENDOR 006-HC0-2 V0006

....- 001 - HCD-2 WCNOC V0008

[ -

~ -

-I l--------------------<ll--------,:()1:f--------------,

1

.----------r---i~AA'.A'Jv' V0J08 M*

FILTERS I_ - - - - - - - - - - _:

ULTRA ~

YS

  • 0003

~-----~

TRANS.

000gA, 0001 I FHDI~
  • I FHD02 I*

L _ _ I

'-._./

I TANK THD01 B !

L -

- I I

,~---

NOTE 3

! SHD01 B !

LARGE DECON.

TANK B HEATER

! EHD01 A ! H~

1 1 /2 NOTE 8

\\..

PUMP

---l-'...:...-1-'-3_1_4 ____ -+--~

I y'

/

F F

I

\\ I or**-- I X 1/4

-/ \\

I.I ]

T ::,

V0030 02g-HC0-1 _/ V0031 PHD01 B !

VENDOR V001 3 WCNOC 028-HCD 012-HCD-1 1 /2 J

SEE NOTE 11

[ -------------l---+----,'---------------------1:,():1-------------,

,~,

~ ' -

V0009 M-I 2H001 YS 0002

~*

0001

'-,-/

V0106 FILTERS D u I

FLANGE~

1~

TL _____ _JIL->--'0:..:3:..:sc...-c...H.:.c.:.o-_J:_ _____ D- ____ L~~B_J~~H~~--z_ ~1_2 _ ___________ -)ul :M~~:F~:*1; CRW C H-3)

'--- 021-HC0-2 TANK I F HDI~

  • F H_0_0_4----,I *

~--+'-+-+'--'3::/...:4 ___ --+f--b F

F c E-31 THD01 A !

! SHD01 A !

LARGE DECON.

TANK A AUXILIARY BUILDING HOT MACHINE SHOP 1 1 12

'y' V0012 VENDOR WCNOC

-- 034-HC0-2

\\..

I PUMP

\\I PHD01 A !

026-HC0-1 011-HCD-1 1 /2 040-HCD-1

(\\

Tr---1 x 114 -~-1~-1 i,---,114*~11--J c,1-..ii,.:.,+-:J V0028 027-HC0 V002g 021-HCO-~ ~

032-HCD-2 N

0 u I

N EQUIPMENT DRAIN e---'0'--4_7_-_HCccDc..--=2 ________ - - - - - - - - > M-I 2L F 06 >

CRW f-~-=::J "-._

c E - 31 f-~-=::J~SEE NOTE 10 3/8' NOTES

1.

THE ONLY PORTIONS OF THIS SYSTEM WHICH ARE 0-LISTED ARE THE PIPING AND VALVES THAT ARE ASSOCIATED WITH THE CONTAINMENT PENETRATION.

2.

18 KW ELECTRIC I MIVERSI ON HEATER ( 316Ll WI TH BUILT - IN THERMOSTAT.

3.

THREE IMMERSIBLE ULTRASONIC TRANSDUCERS WITH SUPPORT RACK ( 316Ll, LOW LEVEL SENSOR, ANO 50 CABLE.

4.

AIR -

COOLED ULTRASONIC GENERATOR WITH REMOTE CONTROL.

5.

HOSE CONNECT! ON.

6.
DELETED,
7.

DELETED.

8.

36 KW ELECTRIC IMIVERSION HEATER ( 316L) WITH BUILT - IN THERMOSTAT.

g, REFERENCE CCP 111 46

10. 3/8' Pl PE CONNECT! ON TO ACCOMMODATE TEST EOUI PMENT.

FT.

11. VALVE HD-V009 LEFT IN SYSTEM TO UTILIZE PIPE SUPPORT a:

0 D z w

1 0 z u a:

0 D z

1 0 z ',

a:

0 D z

~I 0 z ',

L0-068-HX0-2 BURIED HOT MACHINE SHOP PIPE TRENCH CHEMICAL DRAIN TANK


L) __ M_-_1_2_L0_0_1_>

ARW

< E-3>

HCO HXO I

- FR f'v1..'-. ~I~ ~IT;_ '(
JL;~

~~ S[~\\/J SEE NOTE 9.

~---1>----- ( JgJ SPRAY NOZZLES PER HEADER ( TYP.)

\\

\\

\\\\

HBO s>

HBB s

HBB HBO

__ ~ __. -017-H~~-,2

/"7-J

'\\

./

A'cl'.<ILI~

I

r.

\\

P-43

/

SfEAM _)'YSTE0J;l,..

/:

OUTS! OE

,1 I NS! OE 015-HBB-2

---(

REACTOR VESSEL 2FBe\\t '-,./.fl'- -(o .,..;\\J--,-------l~.... ~;_;,::;:;~-,-------+... --'--r-*--;M HEAD OECONTAMI NATI ON

/*"--~<--+-~.. /

I

'I

/

c H-)!1

/'

FBV01 261 V001 6 V001 7 V0020 NOTE 5

/

/

/

I J

oo oo

\\/ FB_;$BB-Hji{l-2 7

)

<jl

'z I/ <'/--t,,,__.,/1 LJ ~

j

~

S

~ ~

/.c'\\

I TEST I

TEST I '

CONN, LJ CONN.

016-HB0-2 1 TEST

& DRAIN CONN.

REACTCJR BUILDING DEMI N.

WATER 1

031 -HC0-1 M; ~~:~01

- --1--~~V~~ i;l -------~~~:;"3-0--------,

AN-110-HCD-1 CASK WASHDOWN Pl T CASK WA,SHDOWN Pl T BOTTOM HEADER TOP HEADER REACTOR N

N.,

MAKE -

UP WATER 033-HC0-2

> M-1 2BL 01 > __ §~ --0~'!_-_HS'?,- ~ ____._.,_~01!.:8!_:-_!:H~c!!.0-:.:2'--~"'-f--_JL_-,,---.!:0:!..1 ~8-:,:H::acaao::.-:;.z __________..1. ____________._.

~--, -A--3-,--

V0039 V001 5 V00'36 01g-Hco-2 N " "

DRAIN &

HOSE CONN.

FUEL BUILDING 018-HCD-2

\\,1111,,,

,, co G L,,,

D" "t II d

,,,,...!'....... :... 01<,

1g1 a y s1gne

," 0.*. ENSi;'**. Q ",

<;i_ ** -:.,,c O *-..

~ by Donald Gene

~j\\ >12.:., ~
i 10021--~ = Long

~~;*-.

_./$} Date: 2013.08.07

"'O *.

k:

~.,.ff"...

  • ,,"'.sss*-..~N~~~;i.<>,,'

16:16:37 -05'00'

', IONA\\."',,

,,,,,1111

(ID REVISED Q ISSUED USAl'l FIG. 12.3-4-00 ESSE:NTIAL DRAWING INCORPORATED CR* 00058142*01*01 CHG. DOC.

THIS DWG. SUPERSEDED BY REV.

IHJS OWG. SUPERSEDES REVISION l()TES1 CHANGE PKG. NO.

REV.

014518 ELECTRONIC APPROVAL PIPING AIND INSTRUMENTATION DIAGRAM DECONl-AMINATION SYSTEM SCALE DRAWING NUMBER SHEET NONE M-12HD01 10 1111 11111111111111 11 111111 34X44 E SIZE M*12HD01*1*10 H

G F

E D

C B

A