05000272/LER-1980-063-01, /01X-1:on 801208,found That Auxiliary Feedwater Pumps 11 & 12 Could Be Stopped from Control Console If Steam Generator Low Low Level Is Received During Safeguards Equipment Control Sys Operation.Caused by Design Error

From kanterella
(Redirected from ML18085B121)
Jump to navigation Jump to search
/01X-1:on 801208,found That Auxiliary Feedwater Pumps 11 & 12 Could Be Stopped from Control Console If Steam Generator Low Low Level Is Received During Safeguards Equipment Control Sys Operation.Caused by Design Error
ML18085B121
Person / Time
Site: Salem 
Issue date: 03/25/1981
From: Steele W
Public Service Enterprise Group
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML18085B120 List:
References
LER-80-063-01X, LER-80-63-1X, NUDOCS 8104020551
Download: ML18085B121 (1)


LER-1980-063, /01X-1:on 801208,found That Auxiliary Feedwater Pumps 11 & 12 Could Be Stopped from Control Console If Steam Generator Low Low Level Is Received During Safeguards Equipment Control Sys Operation.Caused by Design Error
Event date:
Report date:
2721980063R01 - NRC Website

text

NRC FORM 366

..,,,77) L..*

e LICENSEE EVENT REPORT U.S. NUCLEAR REGULATORY COMMISSION I

CONTROL BLOCK: l l I I I l 1 Q (PLEASE PRINT OR TYPE ALL REQUIRED INFORMATION)

,- '1 1

6 1il2J IN IJ Is I GI sl1 l@I ol ol -1 ol ol ol o! ol-1 ol olG)l4I1l 1l 1l 1101 I 10 7

8 9

LICENSEE CODE 14 15 LICENSE NUMBER 25 26 LICENSE TYPE 30 57 CAT 58 CON"T [ITIJ 7

8

~~:~~~ LJJ©I ol s I o Io I o I 2 I 7 I 210)1 1 I 2 I o I 8 I 8 I o l@I o I 3 12 I s I s 11 I G) 60 61 DOCKET NUMBER 68 69 EVENT DATE 74 75 REPORT DATE BO EVENT DESCRIPTION AND PROBABLE CONSEQUENCcs@

[£]2J I During routine surveillance testing, it was found that the Nos. 11 and 12 Auxiliary

!]JI]

Feedwater Pumps could be stopped from the control console if a Steam Generator low [QJ}]

low level signal is received during Safeguards Equipment Control System operation.

[Q))J This is a malfunction of a safety-related system and is a violation of Technical Specification 6.9.1.8.e.

No previous occurrences.

[§]IJ 7

8 9 80

~

7 8

SYSTEM CODE le I HI@

9 10

CAUSE

CAUSE CODE SUBCODE

@J@ w@

11 12 COMPONENT CODE I z I z I z I z I z I z I@

13 18 SEQUENTIAL OCCURRENCE

~

LE R RO CVENT YE.11.R REPORT NO.

CODE v

NRJ~~~~ I 8 l 0 I I l I 0 I 6 l 3 I I/ I I 0 11 I 21 n

23 24 26 21 20 29 COMP.

SUBCODE

~

19 REPORT TYPE w

30 VALVE SUBCODE

~@

20 l=1 31 ACTION FUTURE EFFECT SHUTDOWN

~

ATTACHMENT NPRD-4 PRIME COMP.

SUPPLIER REVISIOfl/

NC.

Ll:...J 32 COMPONEt-.;T MANUFACTURER TAKEN ACTION ON PLANT METHOD HOURS ~ SUBMITTED FORM ~UB.

12:..J@UJ@

~@ ~ I o Io I o Io I W@

l2U(§)

33 34 35 36 3 7 40 41 42

~ I z I 9 I 9 I 9 I@

CAUSE DESCRIPTION AND CORRECTIVE ACTIONS @

43 44 47

~

I Design error.

Design Change Request l-EC-1084 was issued and implemented on December 6, 1980 to preclude manual operation of the Auxiliary Feedwater Pumps during Safeguards Equipment Control System operation for Unit 1.

Design Change IIIIJ I Request 2-EC-1085, implemented on February 24, 1981, will accomplish the same for OJI)

Unit 2.

7 B

9 80 FACILITY STATUS

% POWER OTHER STATUS METHOD OF A

Gm l.£J@ I ol ol ol@I N/A s

9 10 12

._n ___ __. _____

44 DISCOVERY DISCOVERY DESCRIPTION ~

L!J~... l ___ s_u_r_v_e_i_l_l_a_n_c __

e __

T_e_s_t ______________ __,

7 ACTIVITY CONTENT t::;;-..

RELEASED OF RELEASE AMOUNT OF ACTIVITY ~

EEJ L!.J @ W@)l N/A 7

8 9

10 11 PERSONNEL EXPOSURES r:;;;,,

NUMBER

(:;'::;\\TYPE

DESCRIPTION

45 46 44 45 LOCATION OF RELEASE @

N/A 80 80 EEi I ol ol 0J0~@

NA 8

9 11 121

... 3-----=<--=-=----------------------------------80 PERSONNEL INJURIES r;;':;\\

NUMBER DESCRIPTION~

~

I ol o I ol~

NA 7

8 9

111

... 2-------~'-=--------------------------------8-0 LOSS OF OR DAMAGE TO FACILITY '4J\\

TYPE

DESCRIPTION

\\;!;I 8:TI L!J@

NA 7

8 9

1~0~----------_..;;.;;,_.;;.;;._------------------------------......,BO PUBLICITY I'::'\\

ISSUEDt,;:;\\ DESCRIPTION~

ITTIJ w~

N A 1 1 1 1 1 1 1 1 1 1 NRC USE ONLY

"' I I - ~

8 9

1~0---5--5--1-------------=-=-----------------------------------~6B 69

~1"4020 NAME OF PREPARER w. J. Steele PHONE: _____

6_0_9_-_9_3_5_-_0_9_9_8 _____ _

80 ;;