05000272/LER-1980-059-03, /03L-0:on 801028,action Statement 3.9.2 Was Entered Due to Loss of Audio Count Rate.Caused by Broken Card Holder in Count Rate Drawer Due to Cables Catching Edge of Circuit Board.Card Holder Replaced & Warning Issued

From kanterella
(Redirected from ML18085A307)
Jump to navigation Jump to search
/03L-0:on 801028,action Statement 3.9.2 Was Entered Due to Loss of Audio Count Rate.Caused by Broken Card Holder in Count Rate Drawer Due to Cables Catching Edge of Circuit Board.Card Holder Replaced & Warning Issued
ML18085A307
Person / Time
Site: Salem PSEG icon.png
Issue date: 11/26/1980
From: Osuch J
Public Service Enterprise Group
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML18085A306 List:
References
LER-80-059-03L, LER-80-59-3L, NUDOCS 8012020488
Download: ML18085A307 (1)


LER-1980-059, /03L-0:on 801028,action Statement 3.9.2 Was Entered Due to Loss of Audio Count Rate.Caused by Broken Card Holder in Count Rate Drawer Due to Cables Catching Edge of Circuit Board.Card Holder Replaced & Warning Issued
Event date:
Report date:
2721980059R03 - NRC Website

text

7-771 Ll~ENSE~ EV~~T RE~~~~

  • CONTROL BLOCK: I I I 10 CPU.ASE PAINT OR TYPE ALL REQUIRED INFOAMATIONI I

e D--l-d-1-N-J Is l--Gf-sl1 J@ ol ol -I ol ol ol ol ol -1 ol of@l4 I 1l 1l 1l il©I I I@

8 9

LICENSEE CODE I*

15 LICENSE NUMBER

    • 25 ---*21*-:-**

LICENSE*TVttE-~.IO 57--CkT-SS--*---

CON'T ITil-----:~~~! l.2J©I ol sl"olo I ol 2111 2K!)l1lo12 ls ls lo IG)llJl 1216 I BI al@

B 60 61 DOCKET NUMBER iB 19 EVENT DATE 74 75 RE,ORT DATE 110 EVENT DESCRIPTION AND PROBABLE CONSEQUENCES@

m-f Actl~ Statement-3.9.2 was entered at 1930 hours0.0223 days <br />0.536 hours <br />0.00319 weeks <br />7.34365e-4 months <br /> because the audio count rat~-~~~---------*--------

- o--f-3-l+io.s.t---The_audio.. count rate drawer was replaced and the Action Statement terminated

~f..i..l-l-a1;*_~Q.4!l..liQi?-:t's_. ___ The_ loss of the audio count rate removes the capabil~ty _of the Con-.

--0-l..s.+-+t:r.Ql.J~.9_Qlll.. ~m.(i __ con.tainment personnel hearing changes-in the reactivity condition of the I

))!]-+core...... _ S.i.mil.ar... occurrence 79-3 7.

.. 0-.j.7..1-__

  • B!J*

1 B 9 SYSTEM CODE I II El@

9 10

CAUSE

CAUSE COMP.

CODE SUBCOOE COMPONENT CODE SUBCOOE L!J w@

II NI s1 Tt RI u1e ~

11 12 13 18 19 SEQUENTIAL OCCURRENCE REPORT VALVE SUBCOOE L!.J@

20

~

LEI! RO LVENT YE~.R REPORT NO.

CODE TYPE

~

REPORT I a I o I I I.

I o 1 s I 9 I I.....-1 1£ 13 I L!J I I

'\\UMBER 21 22 23 24 26 27 28 29 30 31 ACTION FUTURE EFFECT SHUTDOWN (22\\

ATTACHMENT NPR0-4 PRIME COMP.

REVISION NC.

l...£J 32 COMPONENT MANUFACTURER TAKE'~

ACTION ON PLANT METHOD HOURS ~ SUBMITTED FORM l>UB.

SUPPLIER

~@W@ ~@) ~ I 01 °1 °,

I l!J@ L!Ll ll!J@

33 34 3~

36 37 40

  • 2 43 IW 11 12 JO I CAUSE DESCRIPTION AND CORRECTIVE ACTIONS @
  • 7 IA card holder broke in the audio count rate drawer when the drawer was taken out be-

[))JJ 1cau~e cables that ha~g down in the cabinet caught the edge of a circuit board.

The IIl1J I card holder was replaced and signs are being installed warning people to insure that DJ)) I the cables clear the circuit boards when they are removing the drawers.

lJE) 7 B

9 FACILITY lj()\\

STATUS

~;,POWER OTHER STATUS ~

ETIJ U!J@ I g 0 I 0 l@I N/A I

7 8

9 10 12 11 _________..

ACTIVITY CONTENT

~

RELEASED OF RELEASE AMOUNT OF ACTIVITY ~

ITIIl L.~J@. W@I.

  • n
  • N/A I

7 8

9 10 11

. PERSONNEL EXPOSURES

~

NUMBER t::i\\ TYPE DESCRIPTION ~

IO DISCOVERY DISCOVERY DESCRIPTION 32 METHOD OF L!JGJ}... l ___ 0p...;;;...e_r_a_to_r __

o_b_s_e_r_v_a_t_io_n ____________ I

~

~

~

LOCATION OF RELEASE @

N/A

- 10 Em I 0 I 0 I 0 lL!J@

N A 7 8 9 11 12

,~3---------------~~-~----~--~----~-----.....

'ERSONNEL INJURIES

!':':\\

NUMBER DESCRlnlON~

EE I 0 I 0 I 0 l@~I -- ---"N..__.A ____________________ ~

7 8

9 11 12 LOSS OF OR DAMAGE TO FACILITY 143' TYPE

DESCRIPTION

~

EliJ W@

80 N A 7

8 9

10 PUBLICITY I::\\

ao NRC USE ONLY ISSUEOc,;\\ DESCRIPTION~

IIli] L!Lleil 7

B 9

10 N/A I

llllfllllll!I~

_____..,.. -*.. -... NAME-*0F-9REPARER---J_. _c_. _o_su_c_h ________ _

68. "Ii!>"" *-- -**--. -... -

. *110-- ;**-

PHONE* ___ 6_0_9_-_9_3_S_-_o9_9_s _____ _

0 II.

~-***