05000272/LER-1980-055-01, /01T-0:on 801029,unfused Area Found in Root Portion of Butt Weld on Steam Generator 13.Caused by Weld Defect in 1979 Repair.Nondestructive Testing Base Line Data Will Be Completed Before Unit Returned to Svc

From kanterella
(Redirected from ML18085A263)
Jump to navigation Jump to search
/01T-0:on 801029,unfused Area Found in Root Portion of Butt Weld on Steam Generator 13.Caused by Weld Defect in 1979 Repair.Nondestructive Testing Base Line Data Will Be Completed Before Unit Returned to Svc
ML18085A263
Person / Time
Site: Salem 
Issue date: 11/14/1980
From: Randolph J
Public Service Enterprise Group
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML18085A262 List:
References
LER-80-055-01T, LER-80-55-1T, NUDOCS 8011200296
Download: ML18085A263 (1)


LER-1980-055, /01T-0:on 801029,unfused Area Found in Root Portion of Butt Weld on Steam Generator 13.Caused by Weld Defect in 1979 Repair.Nondestructive Testing Base Line Data Will Be Completed Before Unit Returned to Svc
Event date:
Report date:
2721980055R01 - NRC Website

text

.. *:..CGN1ROL BLOCK: I I I I I.

10 (PLEASE PRINT OR TYPE ALL REQUIRED INFORMATION) 1 6

[il!J IN !J Is I GI sl1 l(DI ol ol -I ol ol ol ol ol -1 ol olG)l41!1l!l 1l 1l 1l©I I IG) 7 8

9 LICENSEE CODE 14 15 LICENSE NUMBER 25 26 LICENSE TYPE 30 57 CAT 58 CON'T GITTl 7

8

~~~~~~ L!J© I o I s I o Io I o I 2 I 1 I 2 101 1 I o I 2 I 9 I a I o I© I 1 I l I 1 I 4 I a I o 10 60 61 DOCKET NUMBER 68 69 EVENT DATE

.74

75.

REPORT DATE 80 EVENT DESCRIPTION AND PROBABLE CONSEQUENCES@

I During the Refueling Outage as a follow-up action to repairs, made in 1979 in I)))) I response to NRC Bulletin 79-13, a complete RT and UT examination was performed on Nos. 11, 12, 13 and 14 Steam Generator Feedwater Nozzle to pipe welds.

This examination revealed a linear indication appearing to be an unfused area in the root portion of a butt weld on No. 13. Steam Generator.

LER 79-46 was a related

(£I2J I occurrence.

[))))

7 8 9 80 [ill]

7 8

SYSTEM CODE le I HI@

9 10

~

LER RO CVENT YEP..R

~

J~~~~ I a I o I 21 22

CAUSE

CAUSE CODE SUBCODE COMPONENT CODE W@ W@ Ix I xi xi x1 xix I@

11 12 13 18 SEQUENTIAL OCCURRENCE REPORT NO.

CODE I 0 1 s I 5 I I/I

  • ' 01 l I 24 26 27 28 29 l=J 23 COMP.

SUB CODE

~

19 REPORT TYPE L.'.:.J 30 VALVE SUB CODE

~@

20 l.=l 31 ACTION FUTURE EFFECT SHUTDOWN

{22)

ATTACHMENT NPRD-4 PRIME C.OMP.

SUPPLIER REVISION NC.

UJ 32 COMPO!liEl\\iT MANUFACTURER TAKE"!

ACTION ON PLANT METHOD HOURS l"'O SUBMITTED FORM ::.uB.

W@~@ ~@ ~@) 1°1°1°1 I ~@ L.::1@)

33 34 35 36 3 7 40 41 42 IX 19 19 19 I@

~@

CAUSE DESCRIPTION AND CORRECTIVE ACTIONS @

43 44 47 [I))] I The indication was attributed to a wel~ defect in the 1979 r~pair and was OJI]

subsequently ground out and repaired in accordance with the applicable codes and OJ)) I standards.

Non-destructive testing base line data will be completed prior

((IJ] I to the unit's return to service.

o::m 7

8 9

FACILITY f,;";:;..30.

STATUS

% POWER OTHER STATUS ~

ITE W@ I 0 I 0 I 0 l@)_I ______ N...._/A __

80 METHOD OF DISCOVERY DESCRIPTION DISCOVERY W@I_

Radiograph 8

9 10 12 1'3 ACTIVITY CONTENT

~

. RELEASED OF RELEASE AMOUNT OF ACTIVITY ~

[QI] ~

@ W@I.

N/A 7

8 9

10 11 7

44 45 46 80 LOCATION OF RELEASE @

N/A 44 45 80 PERSONNEL EXPOSURES

~

NUMBER t:::;.. TYPE

DESCRIPTION

[IT2J I 01* 0 I 0 J0UJ@....._,__.... _.-N.... A _________________________

...,.........._~

7 8

9 11 12 13 80 PERSONNEL INJURIES f,;":;\\

NUMBER DESCRIPTION~

EI;] I 0 I 0 I 0 I@

N A 7

8 9

111

~2~~~~~~~.=t.-=~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~-'80 LOSS OF OR DAMAGE TO FACILITY '4J\\

TYPE

DESCRIPTION

\\::.::)

~

~@)~-----....--___.:;N~A:.:.-___________ ~~~----------_,_J 7

8 9

10 80 PUBLICiTY Q\\

ISSUED@DESCRIPTION ~

NRC USE ONLY

~

111.11 IOI

~

12!..J44 NA I I I I I I I I I I I I ;

7 8 91

~0----------~~~~~-=:;..;.;~~~~~~~~~~~--~~..-~~~~-'68 69 80 ;

J. M. Randolph NAMEOFPREPARER....,..,...,,,;.-,,_-~~~~~~~~~~..-..-~..-

80112@0 29, PHONE: ____

6_0_9_-_9_3_s-_o..,.9_9_s ___ _

0 a.