LER-1980-052, Forwards LER 80-052/03L-0
Event date:
Report date:
2721980052R00 - NRC Website

text

Public Service Electric and Gas Company 80 Park Place Newark, N.J. 07101 Phone 201 :430-7000 Mr. Boyce H. Grier Director of USNRC October 10, 1980 Office of Inspection and Enforcement Region 1 631 Park Avenue King of Prussia, Pennsylvania 19406

Dear Mr. Grier:

LICENSE NO. DPR-70 DOCKET NO. 50-272 REPORTABLE OCCURRENCE 80-52/03L Pursuant to the requirements of Salem Generating Station Unit No. 1 Technical Specifications, Section 6.9.1, we are submitting Licensee Event Report for Reportable Occurrence 80-52/03L.

This report is required within thirty (30) days of the occurrence.

Sincerely yours,

/

{?~(/

fl: t * *';-_ tj;e~ ~e F. P.

11tf'i:'Z Z1 General Manager -

Electric Production CC:

D~rector, Office of Inspection and Enforcement. (30 copies)

Director, Office of Management Information and Program Control (3 copies)

. }leport Number:

Report Date:

8.2/03L 10/10/80

.occurrence Date:

9/10/80 Facility:

Salem Generating Station, Unit 1 Public Service Electric & Gas Company Hancock's Bridge, New Jersey 08038 IDENTIFICATION OF OCCURRENCE:

Missed Surveillance CONDITIONS PRIOR TO OCCURRENCE:

Mode 3 Hot Standby DESCRIPTION OF OCCURRENCE:

During a 'record review of previous surveillances in preparation for a reactor startup, it was determined that the required inservice inspection surveillance of valves per Technical Specification 4.0.S had not been completed as required at the previous reactor shutdown.

DESIGNATION OF APPARENT CAUSE OF OCCURRENCE:

Procedure Inadequacy ANALYSIS OF OCCURRENCE:

The surveillance in question must be performed at least each 92 days

  • when in Mode 3, Hot Standby, but cannot be performed while in Mode l~

power operation.

If a reactor shutdown occurs and the surveillance has not been completed within the previous 92 days, it must be per-formed prior to startup.* At present, however, there is no way that performance of this surveillance is flagged during the period between a reactor shutdown and subsequent startup as the scheduling is done on a calendar basis.

CORRECTIVE ACTION

The required surveillance was completed immediately upon identifying the need.

Operating Instruction I.... 3.3, "Hot Standby to Minimum Load", has been corrected by On-the-Spot Change P-11 and is presently being revised to contain an entry in the appropriate mode change checklist to insure that this surveillance is performed in a timely manner.

FAILURE DATA:

Not Applicable Prepared By J. M. Randolph Manager -

S~lem Generating Station SORC Meeting No.

77-80