e PS~G Public Service Electric and Gas Company 80 Park Place Newark. N.J. 07101 Phone 2011430-7000 Mr. Boyce H. Grier Director of USNRC Office of Inspection.and Enforcement Region 1 631 Park Avenue King of Prussia, Pennsylvania 19406

Dear Mr. Grier:

LICENSE NO. DPR-70 DOCKET NO. 50-272 REPORTABLE OCCURRENCE 80-45/03L September 4, 1980 Pursuant to the requireme~ts of Salem Generating Station Unit No. 1 Technical Specifications, Section 6.9.1, we are submitting. Licensee Event Report for Reportable Occurrence 80-45/03L.

This report is required within thirty (30) days of the occurrence.

Sincerely yours,

~

F. P. Li:~

General Manager -

Electric Production CC:

Director, Office of Inspection and Enforcement (30 copies)

Director, Office of Management Information and Program Control (3 copies) 800912*03?5

.S 95-2001 (200M) 2* 78

.."~*<<*** *-*-**


.-~-~---' **-*'.

Report Number:

80-45/03L Report bate:

9/4/80 Occurrence Date:

8/06/80 Facility:

Salem Generating Station, Unit 1 Public Service Electric & Gas Company Hancock's Bridge, New Jersey 08038 IDENTIFICATION OF OCCURRENCE:

Air Particulate Detector Inoperable CONDITIONS PRIOR TO OCCURRENCE:

Mode 1 Reactor Power 82%

DESCRIPTION OF OCCURRENCE:

During routine maintenance on the Air Particulate Detector (APD), it was determined that the pump had seized.

Action Statement 3.4.6.1 was entered at 1907 hours0.0221 days <br />0.53 hours <br />0.00315 weeks <br />7.256135e-4 months <br /> which requires with only two of the required three leak detection systems operable, operation may con-tinue for up to 30 days provided grab samples of the containment atmosphere are obtained and analyzed at least once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> when the required gaseous and/or particulate radioactivity monitoring system is inoperable; otherwise, be in at least hot standby within the next six hours and in cold shutdown within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.

DESIGNATION OF APPARENT CAUSE OF OCCURRENCE:

Equipment Failure ANALYSIS OF OCCURRENCE:

It was determined the pump had seized, but the motor was tested satisfactorily *.

CORRECTIVE ACTION

The pump was replaced from stock and tested satisfactorily.

FAILURE DATA:

Conde Air Pump Model 65F-CW Prepared By M. J. Murphy SORC Meeting No.

68-80

(~*

,t11e4e'-~

Manager~lem Generating Station