1995 Annual Radioactive Effluent Release & Waste Disposal Rept
ML18065A609
Person / Time
Site: Palisades 
Issue date: 12/31/1995
From: Grogan M, Smedley R
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
NUDOCS 9604080313
Download: ML18065A609 (173)


Text

consumers Power*

POW ERi Nii MICHlliAN'S PROliRESS Palisades Nuclear Plant: 27780 Blue Star Memorial Highway, Covert, Ml 49043 March 29, 1996 U S Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 DOCKET 50-255 - LICENSE DPR PALISADES PLANT 1995 ANNUAL RADIOACTIVE EFFLUENT RELEASE AND WASTE DISPOSAL REPORT The enclosed 1995 Annual Radioactive Effluent Release and Disposal Report for the Palisades Plant is being submitted in accordance with 1 O CFR 50.36a.

This report provides information relating to radioactive effluent releases and solid radioactive waste processing during the period of January 1, 1995, through December 31, 1995.

SUMMARY

OF COMMITMENTS This letter contains no new commitments and no revisions to existing commitments.

Richard W Smedley Manager, Licensing CC Administrator, Region Ill, USNRC Project Manager, NRR, USNRC NRC Resident Inspector - Palisades Ens;losuc~

960ll*080313 951231 PDR ADOC~ 05000255 R

PDR YO\\J\\,.'lj;~

A CMS" ENER6YCOMPANY

ENCLOSURE CONSUMERS POWER COMPANY PALISADES PLANT DOCKET 50-255 1995 ANNUAL RADIOACTIVE EFFLUENT RELEASE AND WASTE DISPOSAL REPORT 170 Pages

To

~ DJMalone, Palisades From * ~ MLGrogan, Pali sades Date March 14, 1996 Subject PALISADES PLANT -

ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT - JANUARY - DECEMBER 1995 CC CMMathews, Palisades RWSmedley, Palisades DCC: 950/24*03*10/LP 950/22*07*01*01/LP CONSUMERS POWER COMPANY Internal Correspondence MLG96*009 Attached please find the subject report prepared and reviewed in accordance with Palisades Procedure HP 10.5. This report is believed accurate, pertinent and complete to the best of our ability in meeting the requirements of 10CFR50.36a and Technical specification Section 6.9.3.1.A.

The Palisades Radioactive Effluent Release Report was prepared by MLGrogan, RETS/REMP Analyst, with technical review assigned to TPNeal, HP Environmental Supervisor. Administrative review and report approval was performed by.

DJMalone, Radiological Services Manager.

Report prepared by:

Lill-J-~

MLGrogan, RETS/REMP ~

Technical Review performed by:*

3-10-C('(..

TPNeal, HP Environmental Supervisor Date by:

' PALISADES NUCLEAR PLANT ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT January - December 1995 This report provides information relating to radioactive effluent releases and solid radioactive waste processing at the Palisades Nuclear Plant during the period of January 1, 1995 through December 31, 1995.

The report format is detailed in Plant Technical specification 6.9.3.1.A.

Palisades was off-line from May 23, 1995 to August* 21, 1995 for a Refueling outage.

The Plant was taken off-line on September 11, 1995 at 2106 hours0.0244 days <br />0.585 hours <br />0.00348 weeks <br />8.01333e-4 months <br /> due to a broken conductor in the iso-phase bus underneath the generator.

The Plant was returned to service after repairs completed on September 13, 1995 at 0538 hours0.00623 days <br />0.149 hours <br />8.895503e-4 weeks <br />2.04709e-4 months <br />.

The Plant was removed from the grid at 0537 on December 2, 1995 to repair CROM cooling fan, and to replace 24 flex connectors for the main generator.

The Plant was returned to the grid December 3, 1995 at 1335 hours0.0155 days <br />0.371 hours <br />0.00221 weeks <br />5.079675e-4 months <br />.

1.

Supplemental Information A.

B.

Batch Releases Information relating to batch release of gaseous and liquid effluents is provided in Table HP 10.5-1 (Attachment 1).

Abnormal releases

1)

SIRW Tank Activity Limit Exceeded.

Note: No actual release took place The Effluent Concentration (EC) activity limit of 1000 times EC for the SIRW tank was exceeded on two occasions during the Refueling outage of 1995.

On 7/6/95 (@13:50), the SIRW tank (88%) activity concentration was 1610 times the EC value, after the transfer of Reactor Cavity water back to the tank.

Upon discovery of this event, per the ODCM Appendix A,Section III. K (2) all additions of radioactive material were suspended and within 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> reduce the tank contents wo within limits. The tank was immediately placed on fast recirculation through the demineralizer and the activity was reduced to less than 1000 EC on 7/7/95 at 21:49 (32 hours3.703704e-4 days <br />0.00889 hours <br />5.291005e-5 weeks <br />1.2176e-5 months <br />).

On 7/18/95 the SIRW.tank (6%) activity concentration was 1320 times the EC value.

The tank was again placed on fast recirculation through the demi~eralizer and the activity reduced to 526 EC within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

C.

Lower Limits of Detection (LLD's) for gaseous and liquid effluents are provided in Attachment 5.

j

D.

Radioactive Effluent Monitoring Instrumentation:

1.

Waste Gas Decay Tank Vent Flow Indicator (FI-1121)

The Offsite Dose Calculation Manual (ODCM); Appendix A, Table A-1 requires that when a radioactive gaseous effluent monitoring instrument channel becomes inoperable, best efforts must be made to return the instrument to operable status within 30 days and if unsuccessful, report the incident in the next Radioactive Effluent Report.

The Offsite Dose Calculation Manual, Appendix A, Table A-1 further stipulates that radioactive effluent releases may continue to be made with less than the required amount of operable channels providing that the flow rate is estimated at least once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> for continuous releas~s -0r fours for batch releases.

On July 7, 1993, it.was determined that the flow indicator, FI-1121 was inoperable.

As required per Health Physics Procedure HP 6.6, Evaluation and Release of Waste Gas Decay

.Tank, if FI-1121 is inoperable during Waste Gas Decay Tank batch releases, releases may continue provided the flow rate is estimated by the Primary Side Auxiliary Operator at least every four hours during batch releases. These calculations were performed, as necessary, for all gas batch releases in 1995.

The root cause of the flow indicator problem.is the system design and not the flow indicator itself.

Both the valving sequence and the setpoint of PCV-1123 impacts FIT-1121 operation.

PCV-1123 has a maintenance history of sticking due to crud build-up.

In addition, the PCV is required to be set at the minimum pressure setting (2 psig) to support operation of FIT-1121.

Setting the PCV at the minimum setting of the destgn range is not preferred.

FIT-1121 has a maintenance history of oscillating rapidly (not stabilizing),

and giving a low flow reading compared to the calculated flow rate. The fluctuations in the readings were observed to correspond with slight variance in the outlet pressure of PCV-1123.

Trouble shooting in 1995 included revising the valve line-up in the batching procedure SOP-IBA), and setting the outlet pressure of PCV-1123 prior to batching did not result in reliable flow readings from FIT-1121.

Due to the error in flow readings from FIT-1121, the flow indicator remain tagged inopererable throughout 1995.

In early 1996, under SC 95057, PCV-1123 and all supporting piping and equipment will be removed.

FIT-1121 and all

. supporting piping and equipment will be removed, in addition FI-1121 and all associated air lines will be removed.

A flow orifice plate (R0-1131) will be installed (to restrict the maximum effluent flow rate to below the allowable release limits), and FI-1121 will be removed from the ODCM Appendii A Table A-1 requirements.

During the period of inoperability, all of the Offsite Dose Calculation Manual (ODCM) sampling requirements as stated in Table A-1 were met.

2

  • Gaseous Effluents Table HP 10.5-2 (Attachment 2), Palisades Radioactive Effluent Report, lists and summarizes all gaseous radioactive effluents released during the reporting period.

The unidentified beta was 4.82 E-05% of the total release.

Gaseous effluents released during the first two quarters of 1995 were higher than those respective quarters of 1994.

This was simply a function of Plant operation, as the Plant was shut down most of the first two quarters of 1994.

3.

Liquid Effluents

4.
5.

Table HP 10.5-3 (Attachment 3) lists and summarizes all liquid radioactive effluents released during the reporting period.

The unidentified beta was l.40E-04 % of the total release.

Liquid effluents released during 1995 were higher than those of 1994.

Liquid batch releases increased in 1995 due to extensive equipment drain downs to support Containment Cooler replacement during the refueling outage, and additional controls of silica in the Primary Coolant System.

Solid Waste Table HP 10.5-4 (Attachment 4) summarizes all solid radwaste classification, sources, volume shipped, curie and nuclide content.

Al1 radwaste shipments were made to Barnwell Waste Management Facility in Barnwell, South Carolina.

Summary of Radiological Impact on Man Potential doses to individuals and populations were calculated using GASPAR and LADTAP computer program codes.

The quarterly values for curies released were input for each nuclide and summarized as follows; A.

The offsite air doses at the site boundary (0.48 SSE) due to noble gases were 1.99 E-03 millirad beta and 6.57 E-04 millirad gamma for the first quarter; 7.28 E-03 millirad beta and 2.44 E-03 millirad gamma for the second quarter; 5.60 E-04 millirad beta and 1.54 E-04 millirad gamma for the third quarter; and 1.91 E-04 millirad beta and 6.37 E-05 millirad gamma for the fourth quarter.

The maximum noble gas offsite air dose to the nearest residence (0.50 mi S) for beta and gamma occurred during the second quarter, being 4.88 E-03 millirads beta and l.64E-03 millirads for gamma.

B.

The most restrictive organ dose to an individual in an unrestricted area (based on identified critical receptors) from gaseous effluent releases (tritium, particulate and iodine) was the child bone for the first and second quarter, and infant thyroid for the third and fourth quarters. Doses were 6.53 E-03 millirem for the first quarter; 8.97 E-03 millirem for the second quarter; 1.36 E-02 millirem for the third quarter; and 6.54 E-03 millirem for the fourth quarter.

C.

Integrated total body doses to the general population and average doses to individuals within the population from gaseous effluent release pathways to a distance of 50 miles from the site boundary were:

7.96 E-03 person-Rem and 6.86 E-06 millirem for the first quarter; 1.44 E-02 person-Rem and 1.24 E-05 millirem for the second quarter; 1.48 E-02 person-rem and 1.28 E-05 millirem for the third quarter; and 8.89 E-03 person-Rem and 7.66 E-06 mil 1 irem for the fourth quarter.

D.

The maximum total body dose to an individual in unrestricted water-related exposure pathways was 3.62 E-08 millirem (adult) for the first quarter; 1.56 E-03 millirem (adult) for the second quarter; 1.32 E-02 millirem (adult) for the third quarter; and 1.02 E-02 millirem (adult) for the fourth quarter. The maximum organ doses were 3.62 E-08 millirem (adult) for the first quarter; 2.59 E-03 millirem (teenage liver) for the second quarter; 2.07 E-02 millirem (teenage liver) for the third quarter; and 1.64 E-02 (teenage liver) for the fourth quarter.

The calculated organ dose for the first quarter was the same value as whole body for all organs, since the only isotope released in this quarter was tritium.

E~

Integrated fatal body doses to the general population and average doses to individuals within the population from liquid effluent re 1 ease pathways to a di stance of 50-mil es from the site boundary were:

4.15 E~07 person-rem and 3.58 E-10 millirem for the first quarter; 6.23 E-03 person-Rem and 5.37 E-06 millirem for the second quarter; 4.78 E-02 person-Rem and 4.12 E-05 millirem for the third quarter; and 3.60 E-02 person-Rem and 3.10 E-05 millirem for the fourth quarter.

6.

Process Control Program (PCP No changes were made to the Process Control Program in 1995.

7.

Offsite Dose Calculation Manual (ODCM)

There were several changes to the Palisades Offsite Dose Calculation Manual, Revision 9 during this reporting period as a result of use of the 1994 Land Use Survey.

The Land Use Survey is utilized.to ensure that the impact of effluent dose is accurate. These changes (detailed below) will maintain the level of. radioactive effluent control required by 10 CFR 20.1301, 4 CFR 190, 10 CFR 50.36a, and Appendix I to 10 CFR 50 and do not affect any monitor or release setpoint calculations.

1)

Update of Table 1.4, 1994 Palisades Land Use Census;

2)

Update of Table 1.4a; 1994 Palisades Land Use Census - Critical Receptor Items;

3)

Update of Table 1.9; 1995 Palisades Gaseous Design - Objective Annual Quantities;

4)

Added section III L. "Surveillance Requirement Time Intervals" to ODCM Appendix A, to specify maximum allowable surveillance intervals.

5)

Incorporated Technical Specification Amendment 162 requirements into ODCM Appendix A.

6)

No changes to Appendix B - not sent due to volume.

The revised ODCM and Appendix A, rev 3 is enclosed with this report (Atta~hment 6) along with supporting documentation as per the requirements of Technical specification 6.18.

ATTACHMENT 1 Consumers Power Company Palisades Plant RADIOACTIVE EFFLUENT RELEASE REPORT BATCH RELEASES January - December 1995 1 Page

A.

B.

TABLE HP 10.5-l PALISADES PLANT RADIOACTIVE EFFLUENT REPORT BATCH RELEASES January l, 1995 to December 31, 1995 GASEOUS Units 1st Qtr 2nd Qtr Number of Releases 3

6 Total Release Time Minutes 879 1971 Maximum Release Time Minutes 375 400 Average Release Time Minutes 293 3*29 M~nimum Release Time Minutes 167 207 LIQUID Units 1st Qtr 2nd Qtr Number of Releases 0

1 Total Release Time Minutes N/A 531 Maximum Release Time Minutes N/A 531 Average Release Time Minutes N/A 531 Minimum Release Time Minutes N/A 531 3.rd Qtr 4th Qtr 8

1 2638 342 435 342 330 342 185 342 3rd Qtr 4th Qtr 2

2 1101 1138 627 767 551 569 474 371

ATTACHMENT 2 Consumers Power Company Palisades Plant RADIOACTIVE EFFLUENT RELEASE REPORT GASEOUS EFFLUENTS - SUMMATION OF RELEASES January - December 1995 3 Pages

A. FISSION AND ACTIVATION GASES

1. Total release
2. Average release rate for period
3. Percent of annual avg EC B. IODINES
1. Total Iodine
2. Average release rate for period
3. Percent of annual avg EC C. PARTICULATES
1. Particulates with half-life

> 8 days

2. Average release rate for period
3. Percent of annual avg EC
4. Gross alpha radioactivity
1. Total Release
2. Average release rate for period
3. Percent of annual avg EC E.
1. Beta Airdose at Site Boundary Due to Noble Gases COOCH App A III.C)
2. Percent limit
3. Gamma Airdose at Site Boundary Due to Noble Gases COOCH App A III.C)
4. Percent Limit F.
1. Maximum Organ Dose to Public Based on Critical Receptors CODCM App A II I.D)
2. Percent of Limit TABLE HP 10.5-2 PALISADES PLANT RADIOACTIVE EFFLUENT REPORT GASEOUS EFFLUENTS - SUMMATION OF RELEASES Januarv 1. 1995 to December 31. 1995 Units 1st Qtr 2nd Qtr 3rd Qtr Ci 3.32E+01 1.22E+02 8.58E+OO

µCi/sec 4.27E+OO 1.55E+01 1.08E+OO 1.57E*03 5.75E*03 3.86E-04 Ci 1.00E-03 1.32E-03 2.02E-03

µCi/sec 1.29E-04 1.68E-04 2.54E-04 4.B3E-05 1.12E-04 1.93E*04 Ci 1.86E-05 2.65E-05 3.32E-05

µCi/sec 2.40E-06 3.37E-06 4.17E-06 7.0SE-05 8.89E-05 1.18E-04 Ci 1.20E-06 1.63E-06 1.63E-06 Ci 1.61E+OO 2.83E+OO 3.55E+OO

µCi/sec 2.07E-01 3.60E-01 4.46E-01 3.76E-04 6.SSE-04 8.11E-04 mrads 1.99E-03 7.28E-03 5.60E-04 1.99E-02 7.28E-02 5.60E-03 mrads 6.57E-04 2.44E-03 1.54E-04 1.31E-02 4.88E-02 3.0SE-03 mrem 6.53E-03 8.97E-03 1.36E-02 8.71E-02 1.20E-01 1.81E-01

  • NOTE:

Data is reported for I-131 and I-133 only.

Est Total 4tti Qtr Error %

3.19E+OO 4.01E-01 8.45E+OO 1.48E-04 1.81E-03 2.28E-04 6.31E+OO 1.10E-04 1.54E-05 1.94E-06 5.72E-05 2.3E+01 1.54E-06 2.31E+OO 2.91E-01 5.29E-04 1.91E-04 1.91E-03 6.37E-05 1.27E~03 6.54E-03 8.72E-02

1.
2.

TABLE HP 10.5-2 PALISADES PLANT RADIOACTIVE EFFLUENT REPORT GASEOUS EFFLUENTS January l, 1995 to December 31, 1995 FISSION GASES Units 1st Qtr 2nd Qtr Argon-41 Ci

<LLD

<LLD Krypton-85 Ci 3.51E-Ol 2.06E-Ol Krypton-85m Ci

<LLD

<LLD Krypton-87 Ci

<LLD

<LLD Krypton-88 Ci

<LLD

<LLD Xenon-131m Ci

<LLD 2.55E-01 Xenon-133 Ci 3.28E+Ol 1. 21E+02 Xenon-133m Ci

<LLD 2.24E-Ol Xenon-135 Ci

1. 65E-04 9.23E-02 Xenon-135m Ci

<LLD

<LLD Xenon-138 Ci

<LLD

<LLD Total for Period Ci 3.32E+Ol 1.22E+02 IODINES Iodine-131 Ci 2.66E-04 8.79E-04 Iodine-132 Ci 1.84E-04 2.47E-03 Iodine-133 Ci 7.35E-04 4.42E-04 Iodine-134 Ci

<LLD

<LLD Iodine-135 Ci

1. 55E-05

<LLD Total for Period Ci

1. 20E-03 3.79E-03 3rd Qtr 4th Qtr

<L~D

<LLD 9.56E-Ol

1. 74E-02

<LLD

<LLD

<LLD

<LLD

<LLD

<LLD 1.36E-02 6.16E-03 7.61E+OO 3.17E+OO

<LLD

<LLD 6.62E-04

1. 25E-03 2.07E-03

<LLD

<LLD

<LLD 8.58E+OO 3.19E+OO l.60E-03 7.53E-04

<LLD

<LLD 4.24E-04 l.06E-03

<LLD

<LLD

<LLD

<LLD 2.02E-03

1. 81 E-03
3.

PARTICULATES*

Manganese-54 Cobalt-'sa Iron-59 Cobalt-60 Zi'nc-65 Strontium-89 Strontium-90 Molybdenum-99 I

Cesium-134

-Cesium-137 C.eri um-141 Cer-ium-144 TABLE HP 10.5-2 PALISADES PLANT RADIOACTIVE EFFLUENT REPORT Units 1st Qtr 2nd Qtr Ci

<LLD

<LLD Ci

<LLD

<LLD Ci

<LLD

<LLD Ci

<LLD 2.13E-08 Ci

<LLD

<LLD Ci 6.20E-07 7.70E-07 Ci 3.30E-07 3.20E-07 Ci

<LLD

<LLD Ci

<LLD

<LLD Ci

<LLD 2.77E-06 Ci

<LLD

<LLD Ci

<LLD

<LLD Net unidentified beta Ci

1. 77E-05 2.26E-05 Total 1.86E-05 2.65E-05
  • Particulates with half-lives > 8 days.

3rd Qtr 4th Qtr

<LLD

<LLD

<LLD

<LLD

<LLD

<LLD

1. 31E-06

<LLD

<LLD

<LLD 4.65E-07 4.IOE-07 2.70E-07 1. 95E-07

<LLD

<LLD

<LLD

<LLD 7.22E-07

<LLD

<LLD

<LLD

<LLD

<LLD 3.04E-05 1.48E-05 3.32E-05 1.54E-05

    • Particulates with half-lives < 8 days; not reflected in overall isotopic totals.

ATTACHMENT 3 Consumers Power Company Palisades Plant RADIOACTIVE EFFLUENT RELEASE REPORT LIQUID EFFLUENTS - SUMMATION OF RELEASES January - December 1995 2 Pages

A. FISSION AND ACTIVATION PRODUCTS

1. Total release (not including tritiun, gases, alpha)
2. Average release rate for period
3. Percent of EC B. TRITIUM
1. Total Release
2. Average diluted concentration during period
3. Percent of EC C. DISSOLVED AND ENTRAINED GASES

~1. Total Release

2. Average diluted concentration during period
3. Percent of EC D. GROSS ALPHA RADIOACTIVITY (Total Release)

E. VOLUME OF WASTE RELEASED (Prior to Dilution)

F. VOLUME OF DILUTION WATER USED DURING PERIOD G. MAXIMUM DOSE COMMITMENT -

WHOLE BODY Percent of ODCM App A 111.H limit H. MAXIMUM DOSE COMMITMENT -

ORGAN Percent of ODCM App A 111.H limit TABLE HP 10.5-3 PALISADES PLANT RADIOACTIVE EFFLUENT REPORT LIQUID EFFLUENTS *- SUMMATION OF ALL RELEASES Januarv I. 1995 to December 31. 1995 Units 1st Qtr 2nd Qtr 3rd Qtr Ci

<LLD 7.82E-04 6.23E-03

µCi/ml N/A 5.04E-11 4.48E-10 N/A 3.14E-03 2.69E-02 Ci

1. 72E-02 3.17E+01 5.29E+01

µCi/ml

  • 7.02E-10 2.0SE-06 3.81E-06 7.02E-05 2.0SE-01 3.81E-01 Ci

<LLD

<LLD

<LLD N/A N/A N/A

µCi/ml N/A N/A N/A Ci

<LLD 9.69E-07 3.77E-06 Liters 0.00

1. 73E+05 3.64E+05 Liters 2.45E+10 1.55E+10 1.39E+10 mrem 3.62E-08 1.56E-03 1.32E-02 2.41E-06 1.04E-01 8.BOE-01 mrem 3.62E-08 2.59E-03 2.07E-02 7.24E-07 5.18E-02 4.14E-01 LIQUID EFFLUENTS Est Total 4th Qtr Error %

7.51E-03 1.34E+01 2.99E-10 1.98E-02 4.14E+01 4.01E+OO 1.65E-06 1.65E-01 3.40E-04 1.35E-11 1.97E+01 6.77E-06 4.11E-06 3.29E+05 2.51E+10 1.02E-02 6.BOE-01 1.64E-02 3.28E-01

I.

TABLE HP 10.5-3 PALISADES PLANT RADIOACTIVE EFFLUENT REPORT LIQUID EFFLUENTS January I. 1995 to December 31, 1995 NUCLIDES RELEASED Units 1st Qtr 2nd Qtr Manganese-54 Ci

<LLD

<LLD Coba-lt-58 Ci

<LLD

<LLD lron-5.9 Ci

<LLD

<LLD Cobalt-60 Ci

<LLD 2.06E-04 Z-inc,..65 Ci

<LLD

<LLD

/

Strontium-89 Ci

<LLD 2.25E-07 Strontium,..-90 Ci

<LLD 1.. 26[-06 Molybdenum-99 Ci

<LLD

<LLD Iodine-131 Ci

<LLD

<LLD Ces.ium-134 Ci

<LLD 3.57E-05 Cesium-137 Ci

<LLD

3. 71E-04 Cerium-141 Ci

<LLD

<LLD Cerium-144 Ci

<LLD

<LLD N*i obi Uin-95 Ci

<LLD

<LLD Silver-no Ci

<LLD I. 68E-04 Net unidentified beta Ci

<LLD

<LLD Fission & Activation Product Total Ci 0.00 7.82E-04 Tritium Ci I. 72E-02 3.17E+Ol Grand Total Ci

1. 72E-02 3.17E+Ol 3rd Qtr 4th Qtr

<LLD

<LLD

l. 76E-03 l.6.2E-03

<LLD

<LLD 5.40E-04 l.36E-03

<LLD

<LLD

1. 29E-06 4.79E-06 2.68E-06 2.20E-05

<LLD

<LLD

<LLD

<LLD 5.40E-04 8.13E-04 2.49E-03 3.49E-03

<LLD

<LLD

<LLD

<LLD

<LLD 3.99E-05 7.19E-04 l.58E-04 l.76E-04

<LLD 6.23E-03 7.51E-03 5.29E+Ol 4.14E+Ol 5.29E+Ol 4.14E+Ol

ATTACHMENT 4 Consumers Power Company Palisades Plant RADIOACTIVE EFFLUENT RELEASE REPORT SOLID WASTE January - December 1995 1 Page

SOLID WASTE Waste Source of Class ~~=W=as~t=e'--~

AU DAW AU Resin

Resin TABLE HP 10.5-4 PALISADES PLANT RADIOACTIVE EFFLUENT REPORT January l, 1995 to December 31, 1995 Solidification Agent N/A N/A N/A N/A N/A Container Type LSA LSA HIC HIC HIC Volume

  • Total (cu ft)

Curi es 5620.2 2.298 85.2 0.0003 205.8 1.768 289.8 11.258 617.4 171.687 TOTAL 6818.4 187.011

  • NOTE:

Gamma isotopes are measured quantities; all other isotopes are estimated.

ATTACHMENT 5 Consumers Power Company Palisades Plant RADIOACTIVE EFFLUENT RELEASE REPORT LOWER LIMITS OF DETECTION FOR PALISADES EFFLUENTS January - December 1995 1 Page

LOWER LIMITS OF DETECTION (LLDs) FOR PALISADES EFFLUENTS Gaseous Effluents Nuclide LLD (uci/cc)*

Cr-51 l.25E-13 Mn-54 l.30E-14 Co-58 I. 90E-14 Fe-59 5.84E-14 Co-60 5.26E-14 Zn-65 6.59E-14 Stack Gas Analysis Se-75 I. 20E-14

  1. 's: 95-029-St Nb-95 2.24E-14 and 95-030-St Zr-95 3.36E-14 M0-99 l.41E-13 Sb-125 4.98E-14 1-131 2.93E-14 1-133 3.71E-13 Ce-141 I. 97E-14 Ce-144 5.73E-14 Cs-134 l.67E-14 Cs-137 3.90E-14 Liquid Effluents Nuclide LLD (uci/mll**

Mn-54 1.llE-07 Fe-59 l.93E-07 Co-58 5.38E-08 Co-60 I. 49E-07 Zn-65 2.llE-07 Liquid Batch Release Mo-99 8.76E-07

  1. 's: 95-015-R and I-131 2.03E-07 95-020-R Cs-134 5.76E-08 Cs-137 5.13E-08 Ce-141 2.20E-07 Ce-144 9.63E-07 From typical stack and/or Waste Gas Decay Tank release analysis.

From typical liquid release analysis.

ATTACHMENT 6 Consumers Power Company Pa 1 i sades Pl ant RADIOACTIVE EFFLUENT RELEASE ANO WASTE DISPOSAL REPORT OFFSITE DOSE CALCULATION MANUAL March 31, 1995

r-T

\\J\\U1\\e.,.. c., t..

I \\ "C.- u.~-s.4 Procedure Sponsor Date MLGrogan

/10/19/94 Technical Reviewer Date I

I User Reviewer Date Rev#

~ y~~ I

~3/5S-Pla'flt General Manager Date

r

  • I.

\\

I I.

PALISADES NUCLEAR PLANT OFFSITE DOSE CALCULATION MANUAL Revision 9 Table of Contents GASEOUS EFFLUENTS A.

ALARM/TRIP SETPOINT METHOD

1.

Allowable Concentration

2.

Monitor Response.

B.

DOSE RATE CALCULATION C.

DESIGN OBJECTIVE QUANTITY CDBQ) LIMITS ON BATCH AND CONTINUOUS RELEASES.

1.

Batch Releases.

2.

Continuous Releases

3.

Exceeding DBQ Limits.

4.

Releasing Radionuclides Not Listed in Table 1.9 D. OPTIONAL QUARTERLY DOSE CALCULATIONS.

1.

Methodology for Optional Quarterly Dose Calculations E.

GASEOUS RADWASTE TREATMENT SYSTEM OPERATION

1.

System Description.

2.

Determination of Satisfactory Operation F.

RELEASE RATE FOR OFFSITE EC (50 mrem/yr)

G.

PARTICULATE AND IODINE SAMPLING H.

NOBLE GAS SAMPLING I. TRITIUM SAMPLING.

J.

FIGURES AND TABLES LIQUID EFFLUENTS.

A.

CONCENTRATION

1.

Reguirements.

2.

Prerelease Analysis

3.

Effluent Concentration CEC) - Sum of the Ratios B.

INSTRUMENT SETPOINTS.

1.

Setpoint Determination 2.

Composite Samplers..

3.

Post-Release Analysis 1

1 1

2 3

16 16 17 17 17 18 18 20 20 21 21 22 22 22

. 22 59 59 59 59 60 61 61 61 62

III.

C.

D.

E.

F.

DOSE

1.
2.

PALISADES NUCLEAR PLANT OFFSITE DOSE CALCULATION MANUAL Revision 9 Table of Contents RETS Requirement Release Analysis OPERABILITY OF LIQUID RADWASTE EQUIPMENT RELEASE RATE FOR OFFSITE EC (50 mRem/yr)

FIGURES AND TABLES.

URANIUM FUEL CYCLE DOSE A.

SPECIFICATION B.

ASSUMPTIONS C.

DOSE CALCULATION Appendix A. "Relocated Technical Specification" Appendix B. "Request to Retain Soil in Accordance With 10 CFR 20.302" T

  • 62 62 62 66 66 66 88 88 88 88

_)

I.

A.

PALISADES NUCLEAR PLANT OFFSITE DOSE CALCULATION MANUAL GASEOUS EFFLUENTS ALARM/TRIP SETPOINT METHOD Revision 9 Appendix A.Section III.B.1 requires that the dose rate due to radioactive materials released in gaseous effluents from the site to areas at and beyond the SITE BOUNDARY shall be limited to the following:

For noble gases:

Less than or equal to 500 mrems/yr to the total body and less than or equal to 3000 mrems/yr to the skin. and For iodine-131. for iodine-133. for tritium. and for all radionuclides in particulate form with half lives greater than 8 days:

Less than or equal to 1500 mrems/yr to any organ.

Appendix A.Section III.A.1 requires gaseous effluent monitors to have alarm/trip setpoints to ensure that offsite concentrations. when averaged over 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />. will not be greater than Appendix A.Section III.B.1. This section of the ODCM describes the methodology that will be used to determine these setpoints.

The methodology for determining alarm/trip setpoints is divided into two major parts. The first consists of calculating an allowable concentration for the nuclide mixture to be released.

The second consists of determining monitor response to this mixture in order to establish the physical settings on the monitors.

1.

Allowable Concentration The total EC-fraction (Rk) for each release point will be calculated by the relationship defined by Note 4 of Appendix B. 10 CFR 20:

R(kl = ( ~) (F) ~

c.

_l =

10.0 ECi (1.1) where:

=

=

X/Q

=

F =

Actual or measured concentration. at ambient temperature and pressure of nuclide i (µCi/cc)

The EC of nuclide i from 10 CFR 20. Appendix B.

Table 2 = 50 mrem/yr - total body.

The total EC-fraction for release point k Most conservative sector site boundary dispersion Cl. 79E-06 sec/m3)

Release flow rate (83.000 cfm = 39.2 m3/sec) for stack monitor considerations; variable for other monitors.

1

NOTE:

2.

PALISADES NUCLEAR PLANT OFFSITE DOSE CALCULATION MANUAL Revision 9 If a batch release is made while a continuous release or another batch release is in progress. the sum of all values of Rk must be 1 ess than 10. 0.

Monitor Response Normal radioactivity releases consist mainly of well-decayed fission gases. Therefore. monitor response calibrations are performed to fission gas typical of normal releases (mainly Xe-133).

Response of monitors used to define fission product release rates under accident conditions may vary from that of Xe-133. however.

Monitor response for the two categories of monitor is determined as follows:

a.

Normal Release Caged fission gasses)

Total gas concentration (µCi/cc) at the monitor is calculated.

The calibration curve or constant for cpm/µCi/cc) is applied to determine cpm expected.

The setting for monitor alarms is established at some factor Cb) greater than 1 but less than l/Rk (Equation 1.1) times the measured concentration (c):

s = b x c Cl. 2)

b.

Accident Releases Monitors are preset to alarm at or before precalculated offsite dose rates would be achieved under hypothetical accident conditions. These setpoints are established in accordance with Emergency Plan requirements for defining Emergency Action Levels and associated actions.

Emergency Implementing Procedures contain monitor-specific curves or calibration constants for conversion between cpm and µCi/cc (or R/hr and

µCi/cc). depending on monitor type. for fission product mixtures as a function of mixture decay time.

When these monitors are utilized for other than accident conditions. either an appropriately decayed ttaccidenttt conversion curve may be used. or a decayed fission gas calibration factor may be applied.

In these cases. setpoints are established as in l.A above.

Setpoints of accident monitors (if set to monitor normal releases) are reset to the accident alarm settings at the end of normal release. Setpoints of other release monitors are maintained at the level used at the latest release (well below the level which would allow 10 times EC to be exceeded at the site boundary), or are reset to approximately three times background in order to detect leakage or inadvertent releases

~

of low level gases.

2

PALISADES NUCLEAR PLANT OFFSITE DOSE CALCULATION MANUAL Revision 9 B.

DOSE RATE CALCULATION

1.

Dose rates are calculated for (1) noble gases and (2) iodines and particulates.

Dose rates as defined in this section are based on 10 CFR 50 Appendix I limits of mrem per quarter and millirem per year.

All dose pathways of major importance in the Palisades environs are considered.

a.

Equations and assumptions for calculating doses from noble gase~ are as follows:

1)

Assumptions a)

Doses to be calculated are the maximum offsite point in air. total body and skin.

b)

Exposure pathway is submersion within a cloud of noble gases.

c)

Noble gas radionuclide mix is based on the historically observed source term given in Table 1.1.

plus additional nuclides.

d)

Basic radionuclide data are given in Table 1.2.

e)

All releases are treated as ground-level.

f)

Meteorological data expressed as joint-frequency distribution of wind speed. wind direction. and atmospheric stability for the period resulting in X/Q's and D/Q's shown in Table 1.3.

g)

Raw meteorological data consists of wind speed and direction measurements at lOm and temperature measurements at lOm and 60m.

h)

Dose is to be evaluated at the offsite exposure points where maximum concentrations are expected to exist (overland sector site boundaries). and nearest residents.

i)

Potential maximum population (resident) exposure points are identified in Table 1.4.

j)

A semi-infinite cloud model is used.

k)

For person exposures. credit is taken for shielding by residence (factor of 0.7).

1)

Radioactive decay is considered for the plume.

3

PALISADES NUCLEAR PLANT OFFSITE DOSE CALCULATION MANUAL Revision 9 m)

Building wake effects on effluent dispersion are considered.

n)

A sector-average dispersion equation is used.

o)

The wind speed classes that are used are as follows:

Wind Speed Class Number Range (m/s)

Midpoint (m/s) 1 2

3 4

5 6

7 0.0-0.4 0.4-1.5 1.5-3.0 3.0-5.0 5.0-7.5 7.5-10.0

> 10.0 0.2 0.95 2.25 4.0 6.25 8.75 p)

The stability classes that will be used are the standard A through G classifications. The stability classes 1-7 will correspond to A=l. 8=2..... G=7.

q)

Terrain effects are not considered.

2)

Equations To calculate the dose for any one of the exposure points.

the following equations are used.

For determining the air concentration of any radionuclide:

where:

=

=

p

=

t (

2 )112 fj k Qi P

[

_ (A.

x )]

k==l 1t L zkU j (21tx/n) exp l

uj Air concentration of radionuclide i. µCi/m3.

Joint relative frequency of occurrence of winds in wind speed class j, stability class k.

blowing toward this exposure point. expressed as a fraction.

Average release rate of radionuclide i. µCi/s.

Fraction of radionuclide remaining in plume.

Vertical dispersion coefficient for stability class k (m).

Cl. 3)

PALISADES NUCLEAR PLANT OFFSITE DOSE CALCULATION MANUAL u* J

=

x

=

n

=

A;

=

2rrx/n

=

Revision 9 Midpoint value of wind speed class interval j, mis.

Downwind distance. m.

Number of sectors. 16.

Radioactive decay coefficient of radionuclide i.

-1 s.

Sector width at point of interest. m.

For determining the total body dose rate:

(1.4) where:

Ora

=

Total body dose rate. mrem/y.

X;

=

Air concentration of radionuclide i. µCi /m3.

DFB; =

Total body dose factor due to gamma radiation.

mrem/y per µCi/m3 (Table 1.5).

For determining the skin dose rate:

D5 = ~ Xi (DFSi + 1.11 DFYi) where:

o. 5)

=

=

DFS;

=

1.11 =

DFY.

=

l Skin dose rate. mrem/y.

Air concentration of radionuclide i. µCi/m3 Skin dose factor due to beta radiation. mrem/y per µCi/m3 (Table 1.5).

The average ratio of tissue to air energy absorption coefficients. mrem/mrad.

Gamma-to-air dose factor for radionuclide i.

mrad/y per µCi/m3 (Table 1.5).

5

PALISADES NUCLEAR PLANT OFFSITE DOSE CALCULATION MANUAL Revision 9 For determining dose rate to a point in air:

Da = ~ Xi (DFY i OI DFBi)

Cl. 6) where:

Da Air dose rate. mrad/yr DFB; Air dose factor for beta radiation (Table 1.5).

b.

Equations and assumptions for calculating doses from radioiodines and particulates are as follows:

1)

Assumptions a)

Dose is to be calculated for the critical organ.

thyroid. and the critical age groups (adult. teen.

child. infant). infant (milk) and child (green. leafy vegetab 1 es).

b)

Exposure pathways from iodines and particulates are milk ingestion. ground contamination. green leafy vegetables from home gardens. and inhalation.

c)

The radioiodine and particulate mix is based on the historically observed source term given in Table 1.1.

d).

Basic radionuclide data are given in Table 1.2.

e)

All releases are treated as ground-level.

f)

Mean annual average X/Q's are given in Table 1.3.

g)

Raw meteorological data for ground-level releases consist of wind speed and direction measurements at lOm and temperature measurements at lOm and 60m.

h)

Dose is to be evaluated at the potential offsite exposure points where maximum doses to man are expected to exist.

i)

Real cow. goat and garden locations are considered.

j)

Potential maximum exposure points (Table 1.4) considered are the nearest cow. goat. and home garden locations in each sector.

k)

Terrain effects and open terrain recirculation factors are not considered.

6

PALISADES NUCLEAR PLANT OFFSITE DOSE CALCULATION MANUAL Revision 9

2)
1)

Building wake effects on effluent dispersion are considered.

m)

Plume depletion and radioactive decay are considered for air-concentration calculations.

n)

Radioactive decay is considered for ground-concentration calculations.

o)

Deposition is calculated based on the curves given in Figure 1.2.

p)

Milk cows and goats obtain 100% of their food from pasture grass May through October of each year.

Use default values of 0.58 for cows and 0.67 for goats for fraction of year on pasture.

q)

Credit is taken for shielding by residence (factor of O. 7).

Equations To calculate the dose for any one of the potential maximum-exposure points. the following equations in Section 1.2.2 are used.

a)

Inhalation Equation for calculating air concentration. X~ is the same as in the Noble Gas Section (Equation 1.j).

For determining the organ dose rate:

D.

1 x 10 6 ~ Xi DFii BR i

l Cl. 7) where:

D; Organ dose rate due to inhalation. mrem/y.

X;

=

Air concentration of radionuclide

µCi /m3.

i '

DFI 1 Inhalation dose factor. mrem/pCi (Table 1. 7):.

BR

=

Breathing rate 1400 m3/y infant:

3700 m3 /y child: or 8000 m3 /y teen and adult.

lxl06 pCi I µCi conversion factor.

7

PALISADES NUCLEAR PLANT OFFSITE DOSE CALCULATION MANUAL Revision 9 b)

Ground Contamination For determining the ground concentration of any nuclide:

7 Gi = 3. 15 x 107 L k=l where:

k

=

DR

=

x

=

n

=

2rrx/n

=

=

3.15x107 (1. 8)

Ground concentration of radionuclide i.

µCi /m2.

Stability class.

Joint relative frequency of occurrence of winds in stability class k blowing toward this exposure point. expressed as a fraction.

Average release rate of radionuclide i.

µCi/s.

Relative deposition rate. m-1 (Fig 1.2).

Downwind distance. m.

Number of sectors. 16.

Sector width at point of interest. m.

Radioactive decay coefficient of radionuclide i. y-1.

Time for buildup of radionuclides on the ground. 15 y.

sly conversion factor.

8

io-3 10-4 ~

cc w

w

I cc IM w

~

cc

.1 z 1o-6 0

t=

~

IM Q

w >

j:: <

w a:

1o-I 0.1

~

PALISADES NUCLEAR PLANT OFFSITE DOSE CALCULATION MANUAL Revision 9 Figure 1.2

~

~

--~ II

"""lltO:

1.0 10.0

"'It..

PLUME TRAVEL DISTANCE (KILOMETERS)

I I Corrected January 1977 I

I' I

I l 'I i

I I

! ; I 1 i I

I I

I I

I I

I I i

I I

'lo.

l"I I

~,

I I

I 11 i I

' ' I 1

1 l

I 11 i

100.0 200.0 Fi..,. 7. R.. ltive DIPOlition for Ground Level Rel._ tAH Atmospheric Stability Claatll n - --

9

PALISADES NUCLEAR PLANT OFFSITE DOSE CALCULATION MANUAL Revision 9 For determining the total body or organ dose rate from ground contamination:

DG = (8,760) (1X10 6 ) (0.7) ~ Gi DFGi l

where:

=

DFG.

=

1 8.760 =

lxl06 =

0.7

=

Dose rate due to ground contamination.

mrem/y.

Cl. 9)

Ground concentration of radionuclide i.

µCi /m2.

Dose factor for standing on contaminated ground. mrem/h per pCi/m2 (Table 1.8).

Occupation time. h/y.

pCi/µCi conversion factor.

Shielding factor accounting for a distance of 1.0 meter above ordinary ground.

dimensionless.

c)

Milk and Vegetation Ingestion For determining the concentration of any nuclide (except C-14 and H-3) in and on vegetation:

~ fkQ 1 DR (r[l-exp(-lE1t 0 )]

1-exp

)

CV1 = 3,600 L..,,

+ B1v[ pA, 1

(-litb)] ((exp-(lith)Jj k=l (2n:x/n)

Yv lEi Cl.10) where:

cvi

=

Concentration of radionuclide i in and on vegetation. µCi/kg'.

k =

Stability cl ass.

f k

=

Frequency of this stability class and wind direction combination. expressed as a fraction.

Qi

=

Average release rate of radionuclide i.

µCi/s.

DR

=

Relative deposition rate. m-1 (Figure 1.2).

x Downwind distance. m.

10

PALISADES NUCLEAR PLANT OFFSITE DOSE CALCULATION MANUAL Revision 9 n

=

Number of sectors. 16.

2rrx/n r

\\ Ei

=

p =

3.600 =

Sector width at point of interest. m.

Fraction of deposited activity retained on vegetation (1.0 for iodines. 0.2 for particulates).

Effective removal rate constant.

\\Ei = ;\\; + ;\\w* where ;\\; is the radioactive decay coefficient. h-1
  • and ;\\w is a measure of physical loss by weathering (Aw = 0. 0 0 21 h- ).

Period over which deposition occurs. 720 h.

Agricultural yield. 0. 7 kg/m2.

Transfer factor from soil to vegetation of radionuclide i (Table 1.6).

Radioactive decay coefficient of radionuclide i. h-1 Time for buildup of radionuclides on the ground. 1. 3lx10 h (15Y).

Effective surface density of soil.

240 kg/m2.

s/h conversion factor.

Holdup time between harvest and consumption of food (2.160 hours0.00185 days <br />0.0444 hours <br />2.645503e-4 weeks <br />6.088e-5 months <br /> for stored food).

For determining the concentration of C-14 in vegetation:

CV 14 = 1 x 10 3 X14

( 0. 11 I 0. 16 )

0.11) where:

0.11 =

0.16 =

Concentration of C-14 in vegetation.

µCi/kg.

Air concentration of C-14. µCi/m3.

Fraction of total Plant mass that is natural carbon.

Concentration of natural carbon in the atmosphere. g/m3.

11

PALISADES NUCLEAR PLANT OFFSITE DOSE CALCULATION MANUAL Revision 9 lxl03 =

g/kg conversion factor.

For determining the concentration of H-3 in vegetation:

CV T = 1 x 10 3 XT

( 0. 7 5 ) ( 0. 5 I H )

Cl. 12) where:

0.75 =

0.5 =

H =

lxl03 =

Concentration of H-3 in vegetation. µCi/m3.

Air concentration of H-3. µCi/m 3.

Fraction of total Plant mass that is water.

Ratio of tritium concentration in Plant water to tritium concentration in atmospheric water.

Absolute humidity of the atmosphere. g/m3.

g/kg conversion factor.

For determining the concentration of any nuclide in cow's or goat's milk:

CM; = CV; FM; Qf exp C -;\\; tf) where:

(1.13)

CM; Concentration of radionuclide i (including C-14 and H-3) in milk. µCi/¥.

CV;

=

Concentration of radionuclide i in and on vegetation. µCi/kg.

FM; Transfer factor from feed to milk for radionuclide i. dli (Table 1.6).

Qf

=

Amount of feed consumed by the milk animal per day. kg/d (cow. 50 kg/d or goat 6 kg/d).

\\ i Radioactive decay coefficient of radionuclide i. d-1.

tf-Transport time of activity from feed to milk to receptor. 2 days.

12

PALISADES NUCLEAR PLANT OFFSITE DOSE CALCULATION MANUAL Revision 9 For determining the organ dose rate from ingestion of green leafy vegetables and milk:

D = 1 x 10 6 E CM. DF. UM l

l.
l.

0.14) where:

D =

Organ dose rate due to ingestion. mrem/y.

CM;

=

UM

=

lxl06

=

Concentration of radionuclide i in vegetables or milk. µCi/kg (or liters).

Ingestion dose factor. mrem/pCi (Table 2.1).

Ingestion rate for milk. 330 i/y; for vegetables 26 kg/yr (child). no ingestion by infant.

pCi/µCi conversion factor.

d)

Meat Ingestion (Beef)

To calculate the concentration of a nuclide in animal flesh:

Cf; = Ff; CV; Of; exp CA/s) 0.15) where:

CV; Qf

=

ts

=

Concentration of nuclide i in the animal flesh. pCi/kg.

Fraction of animal's daily intake which appears in each kg of flesh. days/kg (Table 1.6).

Concentration of radionuclide i in the animal's feed (Equation 1.10).

Amount of feed consumed by the cow per day.

50 kg/d.

Average time from slaughter to consumption.

20 days.

13

PALISADES NUCLEAR PLANT OFFSITE DOSE CALCULATION MANUAL Revision 9 To determine the organ dose from ingestion of beef:

D f = E cfi Dfi uf 1

where:

=

=

Ingestion dose factor for age group.

mrem/pCi (Table 2.1) for nuclide i.

Ingestion rate of meat for age group.

kg/y (child-41. teen-65. adult-110).

e)

Organ Dose Rates (1.16)

For determining the total body and organ dose rate from iodines and particulates:

D = Dr + DG + OM + Dv + OF (1.17) where:

D

=

Total organ dose rate. mrem/y.

Dr

=

Dose rate due to inhalation, mrem/y.

DG

=

Dose rate due to ground contamination.

mrem/y.

OM

=

Dose rate due to milk ingestion. mrem/y.

Dv

=

Dose rate due to vegetable ingestion.

mrem/y.

OF

=

Dose rate due to beef ingestion. mrem/y.

3)

The maximum organ dose rate. maximum total body dose rate.

and maximum skin dose rate calculated in the previous section (Sec I.B) are used to calculate design basis quantities as described in Section I.B.1.3.

14

PALISADES NUCLEAR PLANT OFFSITE DOSE CALCULATION MANUAL

~

Revision 9

c.

Design Basis Quantities The design basis quantity of a radionuclide emitted to the atmosphere is the amount of that nuclide. when released in one year. which would result in a dose not exceeding any of the following:

1) 15 millirem to any organ of an individual from iodines and particulates with half-life greater than 8 days (Appendix A.Section III.D.1).
2) 15 millirem to skin of an individual from noble gas (Appendix A.Section III.C.1.b).
3) 5 millirem to the total body of an individual from noble gas (Appendix A.Section II I. C.1. a).

Design basis quantity (Ci) is the smallest value for each nuclide. calculated by dividing the dose limits Ca through c above) by the appropriate dose calculated from the amount of radionuclide (Ci) used to conservatively estimate the doses of Section D. as listed in Table 1.1 (or a hypothetical 1 Ci/year): the result is then multiplied by the amount of radionuclide used.

D DBQ==

DAI (Cc) c where:

DAr Appendix I dose limit Cmrem or mrad).

Dc Calculated dose Cmrem or mrad).

=

DBQ

=

Quantity of nuclide resulting in dose Dc (Ci).

Design Basis Quantity (Ci).

The limiting values for Design Basis Quantities for radionuclides released to the atmosphere are given in Table 1.9.

(1.18)

The inverse of the ratio Cc/Dc in the above equation (ie. Dc/Cc) is a useful value. since it represents the most limiting dose per unit quantity of each nuclide released.

Use of the Dc/Cc ratio in quarterly evaluation of offsite dose is discussed in Section D.

Values of Dc/Cc are given in Table 1.9.

15

PALISADES NUCLEAR PLANT OFFSITE DOSE CALCULATION MANUAL Revision 9

d.. Land Use Census and DBO Changes Appendix A. Sections J.3.b and J.3.c describe the requirements for an annual land use census and revision of the ODCM for use in the following calendar year. Areas of the ODCM which will be reviewed. and changed if appropriate. are Table 1.4 (Land Use Census Data by Sector). Table 1.4a (Critical Receptors).

and Table 1.9 (Gaseous Design Basis Objective Annual Quantities). Changes will be effective on January 1 of the year following the year of the survey.

e.

Gaseous Releases From the Steam Generator Blowdown Vent and Atmosphere Release Valves Releases from the steam generator blowdown vent and atmospheric relief valves are difficult to quantify as there are no sampling capabilities on these steam release systems.

However.

neither system is a normal release path.

The steam generator blowdown vent is normally routed to the main condenser and recirculated. Radioactive releases will be calculated by analyzing steam generator blowdown liquid and assuming that 100 percent of Noble Gases. 10 percent of the Iodines and r._

1 percent of the Particulates will be released to the environment in the steam phase.

Volumes will be released to the environment in the steam phase.

Volumes will be calculated using water balances or alternate means as available.

C.

DESIGN OBJECTIVE QUANTITY (DBQ) LIMITS ON BATCH AND CONTINUOUS RELEASES

1.

Batch Releases Prior to each batch release (waste decay tank release or Containment purge). the quantity of each nuclide identified is summed with the quantity of that nuclide released since the first of the current calendar year.

The cumulative total for each nuclide then is divided by the design objective quantity for each nuclide (from Table 1.9). and the resultant fractions are summed in order to assure that the sum fraction of all nuclides does not exceed 1.0:

E l

Ai

(

)

< 1.0 DBQ i 0.19)

The amount in any calendar quarter should not exceed 0.5. This is checked by subtracting the value obtained at the end of the previous quarter from the value obtained from the cumulative total to date.

including the batch to be released.

16

2.
3.
4.

PALISADES NUCLEAR PLANT OFFSITE DOSE CALCULATION MANUAL Revision 9 Continuous Releases Low level continuous releases from the vent gas collection header and other low level sources are totaled on a weekly basis and summed with any batch releases for the week in order to establish the cumulative DBQ fraction from batch plus continuous released for the year-to-date. Calculations are performed in the same manner as for batch releases described in C.1.

Exceeding DBQ Limits As discussed under B.1.3. the DBQ is a very conservative estimate of activity which could give doses at Appendix I limits.

Because different organs are summed together and doses to different people are summed. the DBQ typically overestimates dose by about a factor of five.

Thus. if calculations of DBQ fraction exceed 1.0 for year-to-date or 0.5 for the quarter. technical specifications probably still would not be exceeded.

However. further discretionary releases should be deferred until an accurate assessment of dose is made by use of GASPAR computer code or by analysis of appropriate release data via the segment gaussian dose model used in emergency planning (inhalation dose. total body external dose. and boundary dose in air). See also Section 0.1.2.

It should be noted that Palisades Plant to date (based on review of semiannual effluent data) has never exceeded the annual or quarterly DBQ fraction. despite its conservatism. Thus. it is not expected that an alternate to the DBQ method will be required unless the Plant is in a significantly off-normal condition.

Releasing Radionuclides Not Listed in Table 1.9 Table 1.9 contains all nuclides identified to date as routine constituents of gaseous releases at Palisades Plant. plus those common to PWRs in general. even if not previously detected at Palisades.

From time to time. however. other nuclides may be detected.

If the unlisted nuclide constitutes less than 10% of the EC-fraction for the release. and all unlisted nuclides total less than 25% of the EC-fraction. the nuclide may be considered not present.

. If the unlisted nuclide constitutes greater than 10% of the EC-fraction. or all unlisted nuclides together constitute greater than 25%. then each nuclide should be assigned a DBQ equal to the most conservative value listed for the physical form of the nuclide involved (noble gas. halogen. or particulate).

Should a nuclide not listed in Table 1.9 begin to appear in significant quantities on a routine basis. revision to this ODCM should be made in order to include a design basis quantity specific to that nuclide.

17

PALISADES NUCLEAR PLANT OFFSITE DOSE CALCULATION MANUAL Revision 9 0,

OPTIONAL QUARTERLY DOSE CALCULATIONS

1.

Methodology for Optional Quarterly Dose Calculations This option may be used in place of. or in addition to. the Design Basis Quantity (DBQ) fraction calculation described by Equation 1.19. This optional conservative calculation relates the OBQ fraction to the doses from which it was originally derived.

Use of this method may assist in identification of the critical dose pathway or characteristics of the assumed critical individual (infant. child. teen. and adult). since Table 1.9 indicates these parameters.

a.

Simplified Conservative Approach This method utilizes a limiting dose concept such that the limiting dose for each nuclide is summed with the limiting dose for each other nuclide. regardless if such sum is physically possible.

It also assumes critical pathways, such as milk and vegetables. are in effect even in winter when the pathway is absent.

As such. the method is highly conservative and significantly over-estimates dose.

If limits appear to be exceeded by this method. Section D.1.2 (a concise method. but requiring computer support) will be utilized.

1.

Assumptions a)

All assumptions of Section 1.1 are utilized.

b)

Limiting doses for each gaseous nuclide are summed.

regardless of limiting decay mode (gamma or beta).

c)

Limiting doses for each particulate and iodine nuclide are summed. regardless of dose point location. exposure pathway, or organ affected.

d)

Doses are summed for detected nuclides such that all nuclides which contribute greater than 10%

individually or 25% in aggregate. to the EC of released radioactivity, are included in the dose calculation.

18

PALISADES NUCLEAR PLANT OFFSITE DOSE CALCULATION MANUAL Revision 9

2.

Equations For determining gaseous effluent dose:

l DG = L AiG(Dc/Cc)iG < 5 millirad/quarter, 10 rnrad/

0 where:

DG

=

Cl. 20)

Dose from gaseous effluents (mrad).

Quantity of gaseous nuclide i released (Ci).

Dose per Ci factor for gaseous nuclide (mrad/Ci).

The limit for this mixture is conservatively taken as that for gamma exposure (5 mrem/quarter. 10 mrem/year) although as indicated in Table 1.9. a majority of the gaseous effluents are beta-limiting and on an individual basis have the higher limit of 10 millirem/quarter and 20 millirem/year.

For determining tritium. particulate and iodine dose to organs:

i DTPI = L ATPii (Dc/Cc)TPii < 7. 5 mrem/q, 15 mrem/y Cl. 21) where:

DTP!

=

=

Dose from particulates and iodines (mrem).

Quantity of particulate or iodine nuclide i released (Ci).

Dose per Ci factor for particulate or iodine nuclide i (mrad/Ci).

19

PALISADES NUCLEAR PLANT OFFSITE DOSE CALCULATION MANUAL Revision 9

b.

Realistic Calculation This methodology is to be U$ed if the highly conservative calculations described in C.l or D.l yield values that appear to exceed applicable limits.

Doses for released particulates. iodines and noble gases will be determined by use of the NRC GASPAR computer code.

The computer run will utilize the annual average joint frequency meteorological data based on not less than 3 years of meteorological measurement. and will reflect demographic and land use information from the land use survey generated in the most recent prior year.

Where appropriate. seasonal adjustments will be applied to obtain realistic dose estimates since both recreational and agricultural activities can vary greatly in relation to season of the year.

An alternative to GASPAR for offsite dose calculation is the use of the Palisades Segmented Gaussian Plume Emergency offsite dose calculation program.

This dose model allows evaluation of dose under the actual meteorological conditions present at the time of release.

It is anticipated that the system may be used in major short-term releases such as Containment purges are to be made under conditions which depart significantly from mean annual conditions.

E.

GASEOUS RADWASTE TREATMENT SYSTEM OPERATION The gaseous radwaste treatment system CGRTS) described below shall be maintained and operated to keep releases ALARA.

1.

System Description

A flow diagram for the GRTS is given in Figure 1-1.

The system consists of three waste-gas compressor packages. six gas decay tanks. and the associated piping. valves. and instrumentation.

Gaseous wastes are received from the following:

degassing of the reactor coolant and purging of the volume control tank prior to a cold shutdown. displacing of cover gases caused by liquid accumulation in the tanks connected to the vent header. and boron recycle process operation.

Design of the system precludes hydrogen explosion by means of ignition source elimination (diaphragm valves. low flow diaphragm compressors and system electrical grounding), and minimization of leakage outside the system.

Explosive mixtures of hydrogen and oxygen have been demonstrated compatible with the system by operational experience over the past 13 years.

20

PALISADES NUCLEAR PLANT OFFSITE DOSE CALCULATION MANUAL

~

Revision 9 F.

2.

Determination of Satisfactory Operation Design basis quantity fraction will be calculated for batch and continuous releases as described in Section I.C.

These calculations will be used to ensure that the GRTS is operating as designed.

Because the Plant was designed to collect and hold for decay a vast majority of the high level gases generated within the primary system. and because the 13-year operating history (to date of writing the initial ODCM) of the Plant has demonstrated the system's consistent performance well below Appendix I limits. no additional operability requirements are specified.

RELEASE RATE FOR OFFSITE EC (50 mrem/yr) 10 CFR 20.1302 requires radioactive effluent releases to unrestricted areas be in concentrations less than the limits specified in Appendix B.

Table 2 when averaged over a period not to exceed one year.

(Note:

there are no unrestricted. areas anywhere within the site boundary as defined by Figure 1-1.) Concentrations at this level if present for one year will result in a dose of 50 mrem whole body.

10 CFR 50.36a requires that the release of radioactive materials be kept as low as reasonably achievable.

However. the section further states that the licensee is permitted the flexibility of operation. to assure a dependable source of power even under unusual operating conditions. to release quantities of material higher than a small percentage of 10 CFR 20.1302 limits but still within those limits. Appendix I to 10 CFR 50 provides the numerical guidelines on limiting conditions for operations to meet the as low as reasonably achievable requirement.

The GASPAR code has been run to determine the dose due to external radiation and inhalation. The source term used is listed in Table 1.1.

The meteorology data is given in Table 1.3.

Dose using annual average meteorology, to the most limiting organ of the person assume to be residing at the site boundary with highest X/Q. is 2.15E-02 mrem (for one year).

The release rate which would result in a dose rate equivalent to 50 mrem/year (using the more conservative total body limit) is the curies/year given in Table 1.1 multiplied by 50/2.15E-02 or 0.11 Ci/sec.

21

PALISADES NUCLEAR PLANT OFFSITE DOSE CALCULATION MANUAL Revision 9 G.,

PARTICULATE AND IODINE SAMPLING Particulate an iodine samples are obtained from the continuous sample stream pulled from the Plant stack.

Samples typically are obtained to represent an integrated release from a gas batch (waste gas decay tank or Containment purge. for example). or a series of samples are obtained to follow the course of a release.

In any event. sample intervals are weekly. at a minimum.

Because HEPA filters are present between most source inputs to the stack and the sample point. releases of particulates normally are significantly less than pre-release calculations indicate. This provides for conservatism in establishing setpoints and in estimation of pre-release design basis quantity fraction.

However. for the sake of maintaining accurate release totals. monitor results (for gases) and sample results (for particulates and iodines) utilized rather than the pre-release estimates. for cumulative records.

Gamma analytical results for particulate and halogen filters are combined for determination of total activity of particulates and halogens released.

Beta and alpha counting also is performed on the particulate filters. Beta yields of the gamma isotopes detected on particulate filters are applied to determine "identified" beta. an the "identified" count rate is subtracted from the observed count rate to give "unidentified" beta.

The "unidentified" beta is assumed to be Sr-90 until results on actual Sr-90 (chemically separated from a quarterly composite of filters) are obtained. Sampling and analysis will be performed per Appendix A. Table B-1 requirements.

H.

NOBLE GAS SAMPLING Noble gases will be sampled from Waste Gas Decay Tanks prior to release and the Containment prior to purging. Analysis of these samples will be used for accountability of noble gases. Off gas will be sampled at least weekly and used to calculate monthly noble gas releases.

Nonroutine releases will be quantified from the stack noble gas monitor (RE 2326) which has a LLD of lE-06 µCi/cc.

Sampling and analysis will be performed per Appendix A. Table B-1 requirements.

I.

TRITIUM SAMPLING Tritium has a low dose consequence to the public because of low production rates. The major contributors to tritium effluents are evaporation from the fuel pool and reactor cavity (when flooded).

Because of the low dose impact. gaseous tritium sampling will not be required. Tritium effluents will be estimated using conservative evaporation rate calculations from the fuel pool and reactor cavity.

22

N w PALISAD~S GASEOUS EFFLUENTS WASTE GAS SURGE TANK RE 2320

_,.c::r~~-...--_..(]....._ __

  • ATMOSl'HERE 1

I I

_.J RE 1113 STACK

~. ;c:

LOW""'l

~

GAS COLLECTION--------< Jo--~J STEAM GENERATOR BLOWDOWN TANk VENT HEADER EAST SAFE GUARD I

AUX I

RE 1811 S\\JPPL Y HEPA (NORMAL!

HEPA/CHARCOAL fRHUEltNGI llLDO 1

RAD -

L-......,~==~L_J"~--.

WASTE R

RE tll09*

RE 0831 HEPAICHAROOAL HEPA CONTAIN-MENT BLDG r---------,

RE 1811 1

FUEL Q

AREA J}f--- SlJ,.'LY RE 6712*

ADOIT

  • nE 11119. 5711 AND !1712 TRIP SUPPL y AND ONE OF r *. \\) l:XHAUSTERS.

FLOW IS NOT Tl'RMINATED PALISADES EFFLUENT FLOW PATHS GASEOUS 1-i G>

c:

o rn

(/)

)>

z:

0

);!

OJ r rn

(/)

o

<D Ul 0.,,

(/)

1-i -u

-1)>

rnr 1-i OVJ O)>

VJO rnrn

(/)

CJ

)> :z:

re:

CJ CJ er

~~

-I ;:;o 1-i 0-U

z:~
3: :z:

)>-I

z:

c:

)>

r

PALISADES NUCLEAR PLANT OFFSITE DOSE CALCULATION MANUAL Revision 9 TABLE 1.1 PALISADES GASEOUS AND LIQUID SOURCE TERMS. CURIES/YEAR (1)

Nuclide Gaseous(2)

Liquid(2)

H-3 5.5 159 Kr-85 4.1 NA Kr-85m 0.12 NA Kr-87 8.4E-02 NA Kr-88 2.lE-01 NA Ar-41 3.lE-02 NA Xe-13lm 2.2 NA Xe-133 1493 NA Xe-133m 0.43 NA Xe-135 1.11 NA Xe-135m 0.3 NA I-131 0.025 3.21E-03 I-132 2.91E-03 NA I-133 6.5E-03 4.7E-05 I-134 4.BE-04 NA I-135 l.84E-02 NA Na-24 l.5E-06 NA Cr-51 2.5E-04 3.9E-03 Mn-54 4.lE-04 7.8E-03 Co-57 2.lE-06 3.2E-05 Co-58 8.6E-04 2.9E-02 Fe-59 6.6E-06

4. lE-04 Co-60 l.lE-03 l.24E-02 Se-75 3.7E-06 NA Nb-95 2.4E-05 4.53E-04 Zr-95 4.7E-06 l.79E-04 Mo-99 1.5E-07 NA Ru-103

.3E-07

.lE-05 Sb-127 NA 3.5E-05 Cs-134 4.5E-05 0.7 Cs-136 NA

1. BE-06 Cs~l37 2.6E-04 l.36E-02 Ba-140 2.BE-07 NA La-140 7.5E-07
l. lE-04 Unidentified beta 3.9E-04 3.3E-03 (1)

Data derived from taking the effluents rel~ased during July-December 1978 through January-June 1982 and dividing by 4.

(2)

Nuclide values listed as NA have not been observed at detectable levels in these waste streams.

24

PALISADES NUCLEAR PLANT OFFSITE DOSE CALCULATION MANUAL Revision 9 TABLE 1.2

. BASIC RADIONUCLIDE DATA NUCLIDE HALF-LIFE LAMBDA BETA1 GAMMA1 (davs) ilill (MEV/DIS)

(MEV/DIS) 1 Tritium 4.49E 03

1. 79E-09 5.68E-03 0.0 2

C-14 2.09E 06 3.84E-12 4.95E-02 0.0 3

N-13 6.94E-03 1.16E"'03 4.91E-Ol

1. 02E 00 4

0-19 3.36E-04 2.39E-02

1. 02E 00
1. 05E 00 5

F-18 7.62E-02 l.05E-04 2.50E-Ol

1. 02E 00 6

NA-24 6.33E-Ol l.27E-05 5.55E-Ol 4.12E 00 7

P-32

1. 43E 01 5.61E-07 6.95E-Ol 0.0 8

AR-41 7.63E-02

1. 05E-04 4.64E-Ol
1. 28E 00 9

CR-51 2.78E 01 2.89E-07 3.86E-03 3.28E-02 10 MN-54 3.03E 02 2.. 65E-08 3.80E-03 8.36E-Ol 11 MN-56 l.07E-Ol 7.50E-05 8.29E-Ol

1. 69E 00 12 FE-59 4.50E 01
1. 78E-07 l.18E-Ol l.19E 00 13 C0-58 7.13E 01 1.12E-07 3.41E-02 9.78E-Ol 14 C0-60
1. 92E 03 4.18E-09 9.68E-02 2.50E 00 15 ZN-69m 5.75E-Ol
1. 39E-05 2.21E-02 4.16E-Ol 16 ZN-69 3.96E-02 2.03E-04 3.19E-Ol 0.0 17 BR-84 2.21E-02 3.63E-04
1. 28E 00
1. 77E 00 18 BR-85 2.08E-03 3.86E-03
1. 04E 00 6.60E-02 19 KR-85m l.83E-Ol 4.38E-05 2.53I-Ol
1. 59E-Ol 20 KR-85 3.93E 03 2.04E-09 2.51E-Ol 2.21E-03 21 KR-87 5.28E-02 1.52E-04
1. 32E 00 7.93E-Ol 22 KR-88 1.17E-01 6.86E-05 3.61E-01
1. 96E 00 23 KR-89 2.21E-03 3.63E-03
1. 36E 00
1. 83E 00 24 RB-88 l.24E-02 6.47E-04 2.06E 00 6.26E-Ol 25 RB-89 1.07E-02 7.SOE-04
1. OlE 00 2.05E-OO 26 SR-89 5.20E 01 1.54E-07 5.83E-01 8.45E-05 27 SR-90
1. 03E 04 7.79E-10 l.96E-01 0.0 28 SR-91 4.03E-Ol 1.99E-05 6.50E-01 6.95E-01 29 SR-92 l.13E-01 7.lOE-05 l.95E-01
1. 34E 00 30 SR-93 5.56E-03
1. 44E-03 9.20E-01 2.24E 00 31 Y-90 2.67E 00 3.00E-06 9.36E-01 0.0 32 Y-91m 3.47E-02 2.31E-04 2.73E-02 5.30E-Ol 33 Y-91 5.88E 01
1. 36E-07 6.06E-01 3.61E-03 34 Y-92 1.47E-01 5.46E-05
1. 44E 00 2.50E-01 35 Y-93 4.29E-01
1. 87E-05 l.17E 00 8.94E-02 36 ZR-95 6.50E 01 1.23E-07 l.16E-01 7.35E-01 37 NB-95m 3.75E 00 2.14E-06 l.81E-01 6.06E-02 38 NB-95 3.50E 01 2.29E-07 4.44E-02 7.64E-01 39 M0-99 2.79E 00 2.87E-06 3.96E-01 1.50E-01 40 TC-99m 2.50E-01 3.21E-05 1.56E-02 1.26E-01 41 TC-99 7.74E 07 1.04E-13 8.46E-02 0.0 42 TC-104
1. 25E-02 6.42E-04
1. 60E 00
1. 95E 00 25

PALISADES NUCLEAR PLANT OFFSITE DOSE CALCULATION MANUAL Revision 9 TABLE 1.2 {continued}

BASIC RADIONUCLIDE DATA NUCLIDE HALF-LIFE LAMBDA BETA1 GAMMA1 (days)

.Ll.ill CMEV/DIS)

CMEV/DIS) 43 RU-106 3.67E 02 2.19E-08

1. OlE-02 0.0 44 TE-132 3.24E 00 2.48E-06 l.OOE-01 2.33E-Ol 45 I-129 6.21E 09 l.29E-15 5.43E-02 2.46E-02 46 I-131 8.05E 00 9.96E-07 l.94E-Ol 3.81E-Ol 47 I-132 9.58E-02 8.37E-05 4.89E-Ol 2.24E 00 48 I-133 8.75E-Ol 9.17E-06 4.08E-Ol 6.02E-Ol 49 I-134 3.61E-02 2.22E-04 6.16E-Ol 2.59E 00 50 I-135 2.79E-Ol 2.87E-05 3.68E-Ol
1. 55E 00 51 XE-13lm l.18E 01 6.80E-07
1. 43E-Ol 2.0lE-02 52 XE-133m 2.26E 00 3.55E-06 l.90E-Ol 4.15E-02 53 XE-133 5.27E 00 l.52E-06 l.35E-Ol 4.60E-02 54 XE-135m l.08E-02 7.43E-04 9.58E-02 4.32E-Ol 55 XE-135 3.83E-0l' 2.09E-05 3.17E-Ol 2.47E-Ol 56 XE-137
2. 71E 03 2.96E-03
1. 77E 00 l.88E-Ol 57 XE-138 9.84E-03 8.15E-04 6.65E-Ol
l. lOE 00 58 CS-134 7.48E 02 l.07E-08
1. 63E-Ol
1. 55E 00 59 CS-135
l. lOE 09 7.29E-15 5.63E-02 0.0 60 CS-136
1. 30E 01 6.17E-07 l.37E-Ol 2.15E 00 61 CS-137
l. lOE 04 7.29E-10 l.71E-Ol 5.97E-Ol 62 CS-138 2.24E-02 3.58E-04
1. 20E 00 2.30E 00 63 BA-139 5.76E-02 l.39E-04

-8.96E-Ol 3.53E-02 64 BA-140

1. 28E 01 6.27E-07 3.15E-Ol
1. 71E-Ol 65 LA-140
1. 68E 00 4.77E-06 5.33E-Ol 2.31E 00 66 CE-144 2.84E 02 2.82E-08 9.13E-02 l.93E-02 67 PR-143
1. 36E 01 5.90E-07 3.14E-Ol 0.0 68 PR-144 l.20E-02 6.68E-04
1. 21E 00 3.18E 00 1 *Average energy per disintegration values were obtained from ICRP Publication No 38. Radionuclide Transformations:

Energy and Intensity of Emissions 1983 and NUREG/CR-1413 CORNL/NUREG-70). a Radionuclide Decay Data Base - Index and Summary Table. DC Kocher. May 1980.

26

USNRC COMPUTER CODE - XOQ[)(JQ, VERSION 2.0 RUN.DATE: 931116

            • PAL!SAOES.XOQDOQ82 *****USING 01/01/86 - 12/31/92 MET DATA**~**

GROUND LEVEL RELEASE - TOP OF CONTAINMENT BUILDING ND DECAY, UNDEPLETED ANNUAL AVERAGE CHI/0 (SEC/METER CUBED)

DISTANCE IN MILES FAOH THE SITI SECTOR O.Z50 O.SOO 0.750 i.ooo l.soo z.ooo 2.soo 3.ooo 3.500 4.000

4. !>OD s

SSW SW WSW w

\\INW NW NNW N

NNE NE ENE E

ESE SE SSE 3.673E-06 1.Z05E-06 6.540E-07 4.310E-07 2.395E-07 1.586E-07 1.153[-07 8.895E-08 7.l*SE-08 5.913E-08 5.006f-08 3.006E-06 9.699E-07 5.193E-07 3.431E-07 l.919E-07 l.278E-07 9.340[-0B 7.233E-08 5.B30E-08 4.839E-08 4.107f-08 3.948E-06 1.259[-06 6.682£-07 4.392E-07 2.445E-07 l.634E-07 1.199[-07 9.308£-08 7.522E-08 6.257E-08 5.321E-08 4.031£-06 1.259[-06 6.556E-07 4.287[-07 2.384E-07 1.606[-07 1.187E-07 9.277E-08 7.537£-08 6.298E-08 5.378£-08 4.756E-06 1.492E-06 7.747E-07 5.051E-07 2.798£-07 1.880[-07 1.387E-07 l.083E-07 8.786E-08 7.336£-08 6.259£-08 6.20*E-06 l.951E-06 1.016£-06 6.622£-07 3.665E-07 2.462[-01 l.816E-07 1.417[-07 l.lSOE-07 9.601E-08 8.192E-08 8.165[*06 2.525E-06 1.308[-06 8.529E-07 4.731E-07 3.203E-07 2.375E-07 l.861E-07 1.515£-07 l.269£-07 l.085E-07 1.071E-05 3.285E*06 1.695[-06 l.103E-06 6.121E-07 4.150£-01 3.085E-07 2.423E-D7 l.976£-07 l.657£-07 l.419E-07 1.093[-05 3.365£-06 l.747E-06 l.140£-06 6.340E-07 4.292£-07 3.l86E-07 2.498E-07 2.035£-07 l.705E-07 1.459(-07 S.439E-06 l.724E-06 9.191E-07 6.049£-07 3.376E-07 2.262E-07 l.662[-07 1.293E-07 l.047E-07 8.716£-08 7.420£-08 5.177E-06 l.720E-06 9.375E-07 6.138£-07 3.376E-07 2.214£-07 1.598£-07 l.Z25E-07 9.786£-08 8.063E-08 6.799£-08 3:743E-06 l.218E-06 6.574E-07 4.293E-07 2:363E-07 l.551E-07 l.120E-07 8.590E-08 6.870E-08 5.664E-08 4.780£-06 3.799E-06 1.264£-06 6.866E-07.4.471E-07 2.447Ec07 l.597E-07 l.148E-07 8.770E-08 6.990[-08 5.746£-08 4.836£-08 3.960£-06 l.323E-06 7.133E-07 4.626[-07 2.519£-07 l.640E-07 l.l77E-07 8.983E-08 7.152£-08 5.874E-08 4.94DE-08 4.526£-06 l.SOZE-06 8.075[-07 5.22JE-D7 2.839E-D7 1.847£-07 l.3ZSE-D7 l.OllE-07 8.046E-08 6.607E-06 5.556E-08 5.087E-06 l.682E-06 9.073E-07 5.906£-07 3.233£-07 Z.115£-07 1.5Z3E-07 1.166£-07 9.306£-06 7.663£-06 6.45/E-08 ANNUAL AVERAGE CHl/Q (SEC/~TER CUBED)

DISTANCE IN MILES FROM THE SITE SECTOR 5.DOO 7.500 10,000 15.000 20.000 ZS.ODD 30.000 35.000 40.000 45.000 50.0UO S

4.315£-08 Z.445[*08 l.639f-08 9.379E-09 6.336E*09 4.662E-09 3.661E-09 2.976E-09 Z.488E-D9 2.126E-09 l.848E-09 SSW 3.548E-08 2.027£-08 l.367E-08 7.884E-09 5.355E-09 3.975E-09 3.ll9E-09 2.543£-09 2.132£-09 l.82SE-09 1.589£-09 SW 4.606E-D8 2.65ZE-08 1.798E-08 l.045f-08 7.l40E-09 5.3Z3E*09 4.l9ZE-09 3.429[-09 2.882E-09 2.474£-09 2.159[-09 VSW 4.671E-08 Z.726E-08 l.866E-08 1.099E-08 7.574£-09 5.686E*09 4.503E-09 3.701£-09 3.124[-09 2.691E-09 2.356E-09 W

5.434E-08 3.165E-08 2.164E-08 l.Z73E-08 8.77DE-D9 6.582£-09 5.ZlZE-09 4.283E-09 3.615£-09 3.ll4E-09 2.726£-09 WNW 7.llOE-08 4.139E-D8 2.829E-08 l.663E-08 I. l45E-08 8.594£-09 6.804E-09 5.589E-09 4.717£-09 4.063E-09 3.556£-09 NW 9.44DE-08 5.540E-08 3.607E-08 2.254E-08 l.56DE-06 1.174£-DB 9.321£-09 7.674E-D9 6.488[-09 5.598E-09 4.907E-09 NNV 1.236E-D7 1.285E-D8 5.D21E-08 2.985E-08 2.071E-08 1.562£-08 l.242E-D8 l.024E-D8 8.668f-09 7.486E-09 6.568E-09 N

l.270E-07 7.462E-08 5.132E-08 3.042E-08 2.106£-08 l.586E-08 1.Z59E-08 l.037E-08 8.770£-09 7.567£-09 6.634E-09

  • MNE 6.428£-08 3.712[-08 2.522E-08 l.470E-08 l.OOSE-08 7.503E-D9 S.914E-09 4.840E-09 4.071E-09 3.496[-09 3.052E-09 NE 5.842E-08 3.272£-08 2.176£-08 l.Z32E-08 8.275£-09 6.088E-09 4.743E-09 3.844£-09 3.206E-09 2.734E-09 2.371£-09 ENE 4.llOE-08 2.310E-08 l.540E-08 8.758E-09 5.900[-09 4.351£-09 3.398E-D9 2.759E-09 2.305E-09 l.968E-09 1.710£-09 E

4.148E-08 2.308E-08 l.528E-08 8.597E-09 5.751E-09 4.218E-09 3.Z79E-09 2.653E-09 2.2D9E-D9 1.881E-09 1.630[-09 ESE 4.234E-08 2.351E-08 l.554E-08 6.734£-09 5.839£-09 4.281E-09 3.328E-09 2.692£-09 2.242E-09 l.909£-09 1.654£-09

. SE 4.763£-08 i.646E-08 J.750£-08 9.846E-D9 6.589E-09 4.836£-09 3.762£-09 3.045[-09 2.538£-09 2.162E-09 l.875E-09 SSE 5.546[-08 3.102E-08 2.061£-08 1.166£-08 7.833E-09 5.764E-09 4.493£-09 3.643£-09 3.040E-09 2.592E-09 2.250£-09 VENT AND OUILDIN6 PARAMETERS:

RELEASE HEIGhT (METERS)

DIAMETER (NETERS)

EXIT VELOCITY (METERS)

ALL GROUND LE~EL RELEASES.

56.10 0.00 0.00 REP. WINO HEIGHT BUILDING HEIGHT BLDG.HlN.CRS SEC.AREA HE.AT EMISSION RATE (METERS)

(METERS)

(SQ.HEHRS)

(CAL/SEC) 10.0 SB. I 2000 0.

O.D 0.,.,

(/)

......... -0

--i )>

rn r CJ (/)

0 )>

o

(/) CJ Cl) rn rn

);;!

(/)

("")

o:J VI

)> :z:

r r c::

rn 0

("") ("")

s c:: r

~

rn l..O

)>

w

o 0

-0

z: £:
3:: :z:

)> --i

z:

c::

)>

r

USNRC COMPUTER CODE ~ XOQOOQ, VERSJON 2.0.

RUH DATE: 931116 11*1* PALISADES XOQDOQ82 1**** USING 01/01/88 - 1£/31/92 MET DAlA *****

GROUND LEVEL RELEASE - TOP OF CONTAINMENT BUILDING NO DECAY, UNDEPLETED CHl/Q (SEC/METER CUBED) FOR EACH 5Eli'tENT 0,,,,

SEGMENT BOUNDARIES lN MILES FROM TH£ SITE

(/)

........ -0 DIRECTION

.5*1 1-2 2-3 3-4 4-5 5* lD 10-20 20-30 30-40 40-50

-I )>

rn r FROM SITE CJ (/)

0

)>

4.714E-09

u

(/) CJ s 6.773£-07 2.461E-07 1.163E-07 7.176E-oa 5.019E*08 2.503E-08 9.585E-09 2.986[-09 2.130E-09 m

rn rn

);!

(/)

4.000E-09.

n SSW 5.411E-07

1. 970£-07 9.415£-08 5.853E-08 4.117f-08 2.072£-08 8.046E~09 2.551£-09
1. 829[-09

)> z

  • ..:i ro

(/l r c:

o r

n n SW 6.978E-07 Z.517E-07 1.206E-07 7.550E-08 5.334[-08 2.707£-06 1.065E-08 5.355E-09 3.439£-09 2.47BE~09 rn 0

3 c: r I-'

~

rn WSW 6.889E-07 2.461E-07 1.195E-07

7. 562E-08 5.3B9E-08 2.776E-08
l. ll7E*OB 5.716£-09 3.71DE-09 2.695£-09 l.O

)>

w

u w 8.142E-07 2.891E-07 1.397E-07 a.a11E-oa 6.273E-08 3.224E-08 l.295E-08 6.618E*09 4.294E-09 3.119£-09 0 -0 z ~

WHW l.067E*06 3.787E-07 l.829E-07 l.154E*07 8.209E-08 4.217E-08 1.692£-08 B.640E-09 5.604E-09 4.069E-09

3: z

)> -I NW l.376E*06 4.898[-07 2.390E-07 l.520E*07 l.067E-07 5.636E-08 2.29lE-08

l. lBDE-08 7.693E-09 5.606[-09 z c:

)>

NNW l.185E-06 6J36E-07 3.104E-07 1.982[-07 l.422E*07 7.407E*08 3.031E-OB 1.570£-06

1. 026£ *08 7.496[-09 r

N l.837E-06

6. 554[.. 07 3.206E*07 2.04ZE-07 l.462f*07 7.590E*D8 3.090E*OB 1.594E-06
l. 040E *OB 7.578[-09 NNE 9.584E-07 3.475E-07 1.675[*07
l. OSOE-07 7.437£-08
3. 781£-08 1.497E-OB 7.548E-09 4.854E-09 3.502[-09 HE 9.675E-07 3.473E-07 1.613[*07 9.832[-08 6.Bl9E-08 3.356E-08 1.262£-08 6.133E-09 3.B58E-09
2. 739[-09

. ENE 6.805£-07 2.431E~07 l.130£-07 6.902E-08

4. 794E*08 2.368f-08 8.965E-09 4.383£-09 2.769E-09
1. 912E-09 E 7.085E-07 2.519£-07 1.159[-07 7.025E-08 4.B50E-08 2.370[-08 8.817£-09 4.251E-09 2 '663£-09 l.885[-09 ESE 7.373E-07 2.597[-07 l.189E-07 7.18BE-08 4.955£-08 2.415E-08 8.960£-09 4.315E-09 2.702£-09
1. 913[-09 SE 8,350£-07 2.928E-07 1.336[~07 8.087E-OB 5.574£-08 2.7l8E-08
1. 010[-08 4.874E-09 3' 057t-09 2.1&7[-09 SSE 9.387£-07 3.330E-07 l.538E-07 9.353E-08 6.47H-08 3.182£-08 1.195~-08 5.807E-09 3.656E-09 2.598[-09

USHRC COMPUTER CODE - XOQDOQ, VERSION 2.0 RUN DATE: 931116

  • O-*- PAllSADE.S XOQOOQ82......... USING 01/01/88 - 12/31/92. MET DATA,.,..,...

GROUND LE.~EL RELEASE - lOP OF CONTAINMENT 8UILOING 2.260 DAY DECAY.

UNDEPLETED

. ANNUAL AVERAGE CHl/Q (SEC/METER CUBED)

OISlANCE IN MILES FROM THE SITE SECTOR 0.250 0.500 0.750 1.000 1.500 2.000 2.500 3.000 3.500 4.000 4.~00 s

SSW SW WSW w

WNW NW NNW N

KNE NE ENE f

ESE SE SSE 3.67DE-06 l.203f-06 6.522E-07 4.294E-07 2.382£-07 l.574E-07 l.14JE-07 8.798£-06 7.055[-08 5 828£-08 4 925£-08 3.003E-06 9.680£-07 5.177£-07 3.418£-07 l.907E-07 1.268£-07 9.249E-08 7.148E-08 5.750[-08 4.763£-08 4 035f-08 3.943E-06 1.256£-06 6.658£-07 4.371E-07 2.428E-07 1.6l8E-07 l.l84E-D7 9.174E-08 7.396E-08 6.137E-08 5.207E-08 4.027£-06 1.256[-06 6.536£-07 4.269£-07 2.368£-07 1.592[-07 l.174E-D7 9.160E-08 7.4Z6E-08 6.192£-08 5.277f-08 4.752E-06 l.489E-06 7.7Z4E-07 5.031E-07 2.781£-07 1.865E-07 1.373E-D7 1.070£-07 8.663£-08 7.216E-08 6.147E-08 6.199E-06 l.94BE-D6 l.013E-OS 6.599E-07 J.646E-07 2.445E-07 l.801E-07 1.403[-07 l.1~6E-07 9.469E-06 8.065[-08 8.158E*06 2.521£-06 l.304E-06 8.50DE-07 4.71ZE-07 J.180E-07 2.354£-07 1.842E-07 1.497[-07 l.251E-07 l.068E-07 l.070E-05 3.280E-06 l.690E-06 l.099E-06 6.090E-07 4.lZZE-07 3.060E-07 2.399[-07 l.954E-07 1.636[-07 1.399£-07 l.092E*05 3.359£-06 1.742£-06 1.136E-06 6.307E-07 4.262E-07 3.158E-07 2*.473[-07 2.0llE-07 l.682E-07 1.437E-07 S.434E-06 l.721E-06 9.167E-07 6~028E-07 3.358£-07 2.246£-07 1.648£-07 1.280E-07 l.034E-07 8.597E-08 7.307E-08 5.173E-06 1.717£-06 9.353E-07 6.ll9E-07 3.36DE-07 2.200E-07 l.585E-D7 l.21JE-07 9.677E-08 7.960E-DB 6.702£-08

  • J.740£-06 1.215£-06 6.557E-07 4.278£-07 2.350£-07 1.540£-07 l.llOE-07 6.498E-08 6.784[-08 S.S83E-08 4.703£-08 3.796[-06 1.262(-06 6.848£-07 4.456£-07 Z.434E-07 l.586E-D7 l.IJBE-07 6.679£-08 6.905E-08 5.666£-08 4.760E-OO 3.957£-06 l.321E-06 7.118E-07 4.613E-D7 2.509£-07 l.631E-07 1.169£-07. 8.905£-08 7.080£-08 5.806E-08 4.875E-06 4.523£-06 1.499£-06 8.056£-07 5.207[-07 2.826E-07 1.835£-07 1.315[-07 1.00lE-07 7.958E-08 6.525£-08 5 478E-08 5.082£-06 l.679E-06 9.0SJE-07 5.887£-07 3.Zl7E-07 2.lOOE~07 l.SlOE-07 1.154E-07 9.198[-08 7.559£-06 6.359E-OB ANNUAL AVERAGE CHI/Q (SEC/METER CUBED)

DISTANCE IN MILES FRON THE SITE SECTlll 5.000

7. 500
10. 000 15.000 Z0.000 25.000 30.000 3~.000 40.000 45.000 50.000 S

4.Z38E-08 2.380£-08 l.582E-08 8.696E-09 5.911£-09 4.299£-09 3.310[-09 Z.650E*09 2.183£-09 1.838£-09 1.575E-09 SSW 3.479f-08 1.969£-08 1.315£-08 7.447£-09 4.969£-09 3.625E-09 Z.797E-09 2.243£-09 1.850£-09 1.560£-09 1.337£-09 SW 4.496E-08 2.5S8E-08 1.715£-08 9.751E-09 6.521£-09 4.763E-09 3.679E-09 2.95ZE-09 Z.436E-09 2.055E-09 1.762[-09 WSW 4.574E-08 Z.641£-08 1.789£-08 1.033£-08 6.986£-09 5.147E-09 4.004£-09 3.233E-09 2.682£-09 2.272E-09 l.95/E-09

. W 5.325£-08 3.07lE-08 2.080£-08 1.201£-08 a:125f-09 5.992E-09 4.666E*09 3.771£-09 3.132E-D9 2.656E-09 2.289£-09 WNW 6.988E-08 4.033£-08 2.733[-08 1.561£-08 1.072£-08 7.915[-09 6.172£-09 4.996E-09 4.issE-D9 3.528£-09 3.045[-09 11\\1 9.278£-08 5.399£-08 3.679f-08 2.143£-08 l.459E-08 J.082E-08 8.459E-09 6.86ZE-09 5.71BE-09 4.863E-09 4.204£-09 NNW l.216£-07 7.lllE-08 4.863(-08 2.848E-08 l.947£-08 1.448E-08 l.135E-08 9.233E-09 7.711E-09 6.572£-09 5.692£-09 H

1.248£-07 7.274£-08 4.963£-08 2.8S5E-08 l.973E-08 1.464E-08 1.145£-08 9.294£-09 7.748E-09 6.593E-09 5.70DE-09 NNE 6.319E-08 3.619£-08 2.439£-DB 1.400£-08 9.430£-09 6.934£-09 5.388E-09 4.347E-09 3.606£-09 3.055£-09 2.632£-09 NE 5.749E-08 3.l95E-08 2.108£-08 l.175E-08 7.778E-09 5.641E-09 4.334E-09 3.465E-09 2.852£-09 2.400E-09 Z.OSSE-09 ENE 4.036£-08 2.249£-08 1.486£-08 8.308E-09 5.505E-09 J.996£-09 3.073[-09 2.458E-09 2.023f-09 l.703E-09 1.459[-09 E

4.076E-08 2.248E-08 1.476[-08 8.l68E-09 5.376E-09 J.882E-09 2.972E-D9 2.369£-09 l.944E-09 l.631E-09 l.l94E-09 ESE 4.l7JE-D8 2.JOOE-08 1.SlOE-08 6.361E-09 5.SlOE-09 3.985E-09 J.055E-09 2.438E-09 2.003E-09 1.683£-09 1.440[-09 SE 4.688E-08 2.584[-08 l.697E-08 9.401E-09 6.200E-09 4.486£-09 3.442E-09 2.749E-09 2.261E-09 l.901E-09 l.627f-09 SSE 5.452£-08 3.023E-08 l.992E-08 l.L09E-06 7.331E-09 5.313E-09 4.079£-09 3.259£-09 2.661E-09 2.255£-09 1.930[-09 VENT ANO BUILOl"G PARAMETERS:

RELEASE HEIGHT (METERS)

DIAMETER (METERS)

EXIT VELOCITY (H£TERS)

All GROUKD LEVEL RELEASES.

58.10 0.00 0.00 REP. MIND HEIGHT (HElERS) 10.0 BUILDING HEIGHT (HElERS) 58.1 BLDG.MIN CRS.SEC.AREA (SQ.METERS) 2000.0 HEAT fHISS!ON RATE (CAL/SEC) 0.0 0

'"Tl

'"Tl

(/)

........ -0

-i )>

m r CJ (/)

0

)>

o

(/) CJ CD m m

-i

(/)

)>

n OJ

(/)

)> :z:

r r c m

0 n n

I c r s

m

\\0

)>

w

o 0 -0
z: ~
3: :z:

)> -i

z:

c

)>

r

USNRC COMPUTER CODE - XOQDOQ, VERSION 2.0 RUN DATE: 931116.

          • PALISADES XOQDOQ82 ***** USING 01/01/88 - 12/31/92 MET DATA *****

GROUND LEVEL RELEASE - TOP OF CONTAINMENT BUILDING 2.260 DAY DECAY, UNDEPLETED CHI/Q (SEC/HETER CUBED) FOR EACH SEGMENT 0 -n SEGMENT BOUNDARIES IN MILES FROM THE SITE

-n

(/)

DIRECTION

. 5-1 1-2 2-3 3-4 4-5 5-10 10-20 20-30 30-40 40-50 1-t -0

-I )>

rr1 r FROM SITE 1-t 0

(/)

s 6.755E-07 2.44BE-07 1.153£-07 7.085E-08 4.938£-08 2.438£-08 9.107E-09 4.333E-09.

2.661E-09 l.843E-09 0 )>

o

(/) 0 CD rr1 rr1 SSW 5.396£-07 1.959£-07 9.323£-08

5. 773£-08 4.045£-08 2.014E-08 7.613E-09 3.652£-09 2.251E-09 l.563E-09

-I

(/)

)>

n w

SW 6.954£-07 2.500£-07 1.193£-07 7.424E-08 5.219£-08 2.614£-08 9.960E-09 4.798£-09 2.963[-09 2.059E-09 OJ

(/)

)> :z

=

r r c rr1 0

n n WSW 6.868E-07 2.446E-07 l.183E-07 7.451E-08 5.288E-08 2.692£-08 1.053[-08 5.180£-09 3.243£-09

2. 277E-09
I c r I-'

s rn w 8.118E-07 2.874E-07 1.383[-07 8.693£-08 6.160E-08 3.132[-08 l.224E-08 6.030£-09 3.783£-09 2.661[-09.

l.O

)>

w

o 1-t WNW l.064E-06 3.768E-07 1.813£-07 l.140E-07 8.082E-08 4.112[-08 1.611E-08 7.965E-09 5.012£-09 3.535[-09 0 -0
z ~

NW 1.373£-06 4.873E*07 2.370E-07 1.502£-07 l.070E-07 5.496E-08 2.181£-08 1.088[-08 6.883£-09 4.872£-09

3: :z

)> -I NNW 1.781£-06 6.305[-07 3.079E-07 1.960£-07 1.401E-07 7.234£-08 2.895E-08 l.456E-08 9.259£-09 6.584E-09

z c

N l.832E-06 6.521E-07 3.178E-07 2.018E-07 1.440E-07 7.404E-08 2.945E-08 1.472£-08 9.322f *09

)>

6.604E-09 r

NHE 9.560E-07 3.457E-07 l.660E-07 l.038E-07 7.323E-08 3.695[-08 l.428E-08 6.981£-09 4.362E-09 3.062£-09 HE 9.653E-07 3.458£-07 l.600E-07

9. 723E-08 6.722E-08 3.280[-08 1.206[-08 5.688[-09
3. 480f-09 2.406£-09 ENE 6.788E-07 2.418£-07
l. lZOE-07 6.816E-08 4.717E-08 2.307[-08 8.519E-09 4.029E-09 2.468£-09 1.707£-09 E. 7.067E-07 2.507E-07 l.149E-07 6.940E-08 4.775£-08 2.311[-08 8.392£-09
  • 3.917E-09 2.379E-09
1. 636£-09 ESE 7.358E-07 2.586E-07 l.181E-07 7.116E-08 4.891E-08 2.365E-08 B.591E-09 4.020E-09 2.449E-09
1. 688E-09 SE 8.331E-07 2.915[-07 1.328[-07 7.999E-08 5.496E-08 2.657E-08 9.659E-09
4. 525£-09 2.761[-09
l. 906[-09 SSE 9.365E-07 3.314E-07 l.525E-07 9.243£-08 6.379E-08 3.lOSE-08 l.138E-08 5.358£-09 3.273[-09 2.261E-09

w USNRC. COMPUTER CO.PE.-

~OQDOq.

VERSION 2. 0 RUN DATE: 931116

          • PALISADES XOQDOQ82 ***** USING 01/01/88 - 12/31/92 HET DATA *****

GROUHO LEVEL RELEASE - TOP OF CONTAINMENT BUILDING 8.000 DAY. DECAY, DEPLETED ANNUAL' AVERAGE* CHl/Q ( SEC/MHER CUBED)

DISTANCE IN MILES FROM THE SITE SECTDR' D.2SO"'

0.500 0.750 I.ODO l.500 2.000 2.500 3.000 3.500 4.000

4. 500 s

SSW SW WSW w WllW IN NNW N

NllE llE EllE E

ESE 5£ SS£ 3.476E-06 l.IOOE-06 5.823£-07 3.769(-07 2.031£-07 1.310£-07 9.318E-08 7.04_3E-08 5.555£-08 4.521£-08 3.767£-0B 2.844E-06 8.852£-07 4.623£-07 3.000£-07 1.627£-07 1.056£-07 7.545£-08 5.726E-08 4.531£-08 3.698£-08 3.089E-OB 3.735E-D6 l.149E-06 5.949£-07 J.839[~D7 Z.073E-07 l.349E-07 9.675E-DB 7.363f-08 5.841£~08 4.777£-08 3.998£-08 3.814£-06 1.149E-06 5.837£-07 J.748£-07 2.021£-07 l.327E-07 9.586£-08 7.342f-08 5.856£-08 4.811£-08 4.044£*08 4.500£-06 1.J61E-06 6.898E-07 4.416£-07 2.372E-07 l.553E-07 l.IZOE-07 8.570£-08 6.828£-08 5.605£-08 4.708£-08

  • 5.870E-06 1.781£-06 9.048£-07 S.791£-07 3.108£-07 2.D35E-07 1.468£-07 l.123E-D7 8.943E-08 7.341£-08 6.166[-08 7.7Z6E-08 2.305E-06 1.164[-06 7.459E-07 4.017E-07 2.647E-07 1.919£-07 l.474E-07 1.178£-07 9.700E-08 8.168£-08 l.014E-05 2.999£-06 1.509£-06 9.646£-07 5.191E-07 3.430£-07 2.493E-07 l.919E-07 l.537E-07 1.267£-07 l.069E-07 1.034E-05 3.072E-06 l.555E-06 9.970£-07 5.376E-07 3.547E-07 2.574f-07 l.979E-07 l.583E-07 1.304£-07 1.098[-07 5.146E-06 l.574E-06 8.184E-07*S.29DE-07 2.863E-07 ).869E-07 l.343E-07 1.024£-07 8.138E-08 6.665E-08 5.586£-08 4.899E-08 l.570E-06 8.349E-07 5.368E-07 2.884E-07 1.830E-07 1.291£-07 9.700E-08 7.611E-08 6.167E-08 5.120E-08 3.54ZE-06 l.lllE-06 5.854E-07 3.754f-07 2.004E-07 1.281E-07 9.048E-D8 6.802E-08 5.341£-08 4.330£-08 3.597E-08
  • 3.595E-06 l.1S4f-06 6.114E-07 3.9lOE-D7 2.075E-07 l.lZOE-07 9.275£-08 6.945£-08 5.435£-08 4 393E-08 3.640£-08 3~747£-06 l.208E*06 6.353E-07 4.046£-07 2.137E-07 l,356E-07 9.516£-08 7.118£-08 5.564£-08 4.494£-08 3.72LE-08 4.283£-06 1.371£-06 7.191£-07 4.568£-07 2.408£-07 l.527E-07 1.071£-07 8.007E-08 6.259£-08 5.054f-06 4.184E-08 4.813£-06 1.535£-06 8.DSDE-07 5.165£-07 2.742E-07 1.748E-07 1.231£-07 9.235[-08 7.239[-08 5.859E-08 4.861E-OB ANNUAL AVERAGE CHl/Q (SEC/METER CUBED) 015TAHC£ IH MILES FROM THE SITE SECTOR 5.000.

7.500 10.000 15.000 20.000 25.000 30.000 35.000

. 40.000 45.000 50 000 S

3.ZOOE-06 1.710£-08 l.090E-08 5.742£-09 3.625£-09 2.5Z5E-09 1.873[~09 1.450£-09 l.l59E-09 9.490E-10 7.920[-10 SSW 2.630E-D8 1.417£-08 9.082E-09 4.821[-09 3.059£-09 2.lJSE-09 l.591[-09 l.235E-09 9.896E-IO 8.l18E-IO 6.766[-10 SW 3.410£-08 1.850E-08 L.191£-08 6.366E-09 4.057E-09 2.847E-09 2.123E-09 l.65ZE-09 1.325E-09 l.088E-09 9.109E-IO WSW 3.461E-08 1.904£-08 l.238E-08 6.709£-09 4.318£-09 3.053E-09 2.292E-09 l.792f-09 l.445E-09 1.192£-09 l.OOIE-09 W

4.027E-08 2.212£-08 l.437E-08 7.780£-09 5.007£-09 3.541£-09 2.658E-09 2.079£-09 l.677E-09 l.384E-09 1.163£-09 WNW 5.Z74E-06 Z.696E-08 l.88ZE-08 l.019E-08 6.559f-D9 4.640£-09 3.484£-09 Z.727[-09 2.200E-09 1.816£-09 L.527£-09 NW 7.00ZE-08 3.876E-08 Z.532E-08 l.381E-08 8.931E-09 6.340£-09 4.775E-09 3.745£-09 3.027£-09 Z.503E-09 Z.IDBE-09 HNW 9.171E-08 5.lOOE-08 3.342E-08 1.831[-08 l.L88E-08 8.451E-09 6.377£-09 5.0llE-09 4.057£-09 J.359E-D9 2.832£-09 N

9.420E-08 5.Z2Zf-08 3,4J5E-08 1.864E-08 L.207E-08 8.569E-09 6.456E-09 5.066£-09 4.096E-09 3.388f-09 2.854£-09 HNE 4.768E-08 Z.598E-08 l.678E-08 9.009£-09 5.762E-09 4.056£-09 3.0JJE-09 2.366£-09 l.903E-09 l.S67E-09 l.314E-09 NE 4.335[-08 2.291E-08 1.449£-08 7.557£-09 4.744E-09 3.292E-09 2.434[-09 l.8BOE-09 l.499E-09 L.225£-09 1.021£-09 ENE 3.048£-08 l.616E-08 1.024£-08 5.362E-09 3.375E-D9 2.347E-09 l.738E-D9 1.344[-09 l.OIJE-09 8.783E-10 7.327E-10 E

3.076£-08 1.615£-08 l.016E-08 5.266£-09 3.292[-09 2.277£-09 1.679£-09 l.294E-D9 1.030E-09 8.403£-10 6.992£-10 ESE 3.143E-08 l.647E-08 l.036E-08 5.362[*09 3.352E-D9 2.319£-09 1.711£-09 l.319E-09 1.051£-09 8.581£-10 7.145E-10 SE 3.534E-08 1.853£-08 1.165£-08 6.040£-09 3.779£-09 2.616E-09 1.931E-09 1.490£-09 1.188£-09 9.703E-10 B.083E-10 SSE 4.114E-08 2.171E-08 l.371E-08 7.146£-09 4.485£-09 3.112E-09 2.301(-09 1.777£-09 1.418£-09 l.159E-09 9.660£-10 VENT AND BUILDING PARAMETERS:

RELE~SE HEIGHT (METERS)

DIA14ETER (METERS)

EXlT VELOCITY (METERS)

ALL GROUND LEVEL RELEASES.

56.10 0.00 0.00 REP. WIND HEIGHT BUILDING fiE !GHT BLOG.H!N.CRS.SEC.AREA HEAT EMISSION RATE

  • ... ~ ' :..

(METERS)

(MEHRS)

(SQ.HETERS)

(CAL/SEC) 10.0

!i8. l 2000.0 0.0 0

"Tl "Tl

(/)

...... 1:1

-; )>

rn r.....

CJ (/)

0

)>

o

(/) CJ CD rn rn

(/)

CJ

)>

)> :z:

OJ VI r

r c rn 0

CJ CJ

3 c r

~ ~

'° w

0 1:1

z:~

3': :z:

)>-;

z:

c

)>

r

USHRC COMPUTER CODE - XOQDOQ, VERSION 2.0 RUN DATE: 931116

          • PALlSADfS XOQDOQ82 ***** USlNG 01/01/88
  • 12/31/92 MET DATA *****

GROUND LEVEL RELEASE - TOP OF CONTAINMENT BUlLDING 8.000 DAY DECAY1 DEPLETED CHl/Q (SEC/HETER CUBED) FOR EACH SEfi1ENT 0

"'Tl

"'Tl SEGMENT BOUNDARIES IN MILES FROM THE SITE Ul 1-i -a OlRECTlON

.5-l 1-2 2-3 3-4 4-5 5-10 10-20

. 20-30 30-40 40-50

~

)>

rn r 1-i FROH SITE 0 Ul 0 )>

o Ul 0 s 6.060E*07 2.097E-07 9.418E-08 5.586E-OB 3.780E-08 1.766£-08 5.947E-09 2.557E-09 l.460E-09 9.531[-10 CD rn rn

---i

(/)

n SSW 4.842E~07 1.678E-07 7.621E-08 4.S55E-08 3.099E-D8 l.460E-08 4.985E-09 2.165E-09 l.243E-09 8.151£-10

)>

)> :z w

OJ Ul r c N

r n ("")

SW 6.243E-07 2.144E-07 9.769E-08 5.870E-08 4.0llE-08 1.904£-08 6.573E-09 Z.880E-09 l.662E-09

l. 093E-09 rn 0

c r

l

~

rn WSW 6.165£-07 2.096E*07 9.670E*08 5.883E-08 4.056£-08 1.954£-08 6.907E-09 3.086E-09 l.803E-09 1.196£-09

)>

\\.0 w

o 1-i w 7.287E-07 2.46ZE-07 1.130£*07 6.860£-08 4.72ZE-D8 Z.ZHE-08 6.012E-09 3.578E-09 Z.091E-09 l.389E-09 0 -a
z: ~

WHW

9. 547[-07 3.227E-07 l.481E-07 8.985£-08 6.184[-08 2.974[-08 1.049E-08 4.689E*09 2.743E-09 l.B23E-09 3: :z:

)> ---i NW 1.232E-06 4.173E-07 l.935E-07 1.183£-07 8.190[-08 3.974E-08 1.420£-08 6.405£*09 3.766E-09 2.512E-09

z c

)>

NHW

1. 598E-06 5.398E-07 2.513E-07 1.543E-07 1.07lf*07 5.223E*08 1.881[-08 8.535£-09 5.038E-09 3.371E-09 r

N 1.644£-06 5.584E-07. 2.595E-07 l.59DE-07 l.lOlE-07 5.351E*08 1.916[-08 8.656[-09 5.094E-09 3.400E-09 NHE 8.~71E-07 2.960E-07 l.356E-07 8.178E-08 5.603E-08 2.671E-08 9.293E-09 4.102£-09 2.380E-09 l.573E-09 NE 8.657[-07 2.961E-07 l.306E-07 7.658E-08 5.139[*08 2.371E-08 7.847£-09 3.336E-09 l.B93E-09 l.23lf~09 ENE 6.089E-07 2.072E-07 9.154["'.08 5.373£-08 3.611[-08 1.671£-08 5.563£-09 2.377£-09 l.353E-09 8.822£-10 E 6.340£-07 2.147E-D7 9.389E-08 5.470£-0B 3.654[-08 1.673[-08 5.476E-09 2.JDBE-09 l.303E-09

8. 442£-10 ESE 6.599£-07 2.214E-D7 9.635E-08 5.60DE-08 3.736[-08 l.708E-08 5.579E-09 2.351£-09 1.329£-09
8. 62DE-10 Sf 7.473E-07 2.496E-07 l.084E-07 6.299E-08 4.201[-08 1.921E-08 6.2B2E-09 2.652E-09
l. 501E-09 9.747E-10 SSE 8.400E-07 2.838E-07 l.246E-07 7.284E-08 4.880[-08 2.247[-08 7.423E-09 3.154£-09 L790E-09 l.164E-09

)

w w

USNRC COMPUTER CODE - XOQOOQ, VERSION 2.0 RUN OATE: 931116

          • PALISADES XOQDOQ82 ***** USING 01/01/88 - 12/31/92 MET DATA *****

GROUND LEVEL RELEASE - TOP OF CONTAINMENT BUILDING RELATIVE DEPOSITION PER UNIT AREA (M**-2} AT FIXED POINTS BV DOWNWIND SECTORS

          • "************* 1 DIRECTION DISTANCES IN MILES FRQlol SITE 0.25 0.50 0.75 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 S

2.434E-08 8.23DE-09 4.226£-09 2.595E-09 l.294E-09 7.845E-10 5.304E-10 3.844E*IO 2.923[-10 2.303E-10 1.864£-10 SSW l.655E-08 5.596E-D9 2.873E-09 l.764E-09 8.795E-10 5.334£-10 3.607E-10 2.614E-l0 l.987E-10 1.566E-l0 1.267£-10 SW l.921E-08 6.497£-09 3.336£-09 2.048E-09 l.021E-09 6.193E-l0 4.187E-10 3.034E-10 2.307E-10 l.818E-l0 1.472£-10 WSW

1. 805E-OS. 6. l.05E-:09 3.135£-09 1. 925E-09 9. 596£-10 5.820E-10 3. 935E-10 2. 851E-10 2.168E-10 l. 708E-l0 l.383l -l0 W

2'. 419E~08 8. ieiE-09 4.200E-09 2. 579£-09 1. 286E-09 7. 799E-10 5. 273E-10 3. 821E-10 2.905E~10 2. 289E-l0 l.853E-10 WNW 3.615E-08 1.222E-08 6.277E-09 3.854E-09 1.921E-09 l.165E-09 7.879£-10 5.710E-l0 4.341E-10 3.420E-10 2.769£-10 NW 4.298E-08 l.454E-08 7.463E-09 4.583E-09 2.285E-09 1.386E-09 9.369[-10 6.789£-10 5.l62E-10 4.067£-10 3.292E-10 NNW 5.435E-08 1.838E-08 9.436E-09 5.794E-09 2.889E-09 l.752E-09 1.185E-09 8.584[-10 6.527E-l0 5.l42E-10 4.l63E-10 N

4. 898E-08 l.656E-08 8.504E-09 5.2Z2E-09 2. 603f-09 1. 579[-09 1. 067£-09 7. 735E-IO 5.8B2E-l0 4. 634E-l0 3. 751E-l O NNE*

2.933E*08 9.919E-09 5.093E-09 3.127E-09 1.559f-09 9.456E-10 6.393E-10 4.633£-10 3.523[*10 2.775E-10 Z.247E-10 NE 4.672£-08 l.580E-08 8.llZE-09 4.981£-09 2.483£-09 1.506£-09 l.018£-09 7.379E-l0 5.611E-10 4.420E-10 3.578E-10 ENE 3.456£-08 l.169E-08 6.00DE-09 3.684[*09 1.837£-09 l.114[-09 7.532[-10 5.458[-JD 4.lSOE-10 3.27DE-IO Z.647[-10 E

3.701E-08 l.251E-08 6.425£-09 3.945£-09 l.967E-09 1.193£-09 8.065[-10 5.844E-10 4.444[-10 3.SOlE-10 2.834E*l0 ESE 4.171£-08 l.410E-08 7.242£-09 4.447£-09 2.217E-09 1.345£-09 9.091[-10 6.588E-10 5.009E-IO 3.946E-10 3.I95E-10 SE 5.332£-08 1.803£-08 9.258£-09 5.685£-09 2.634E-09 1.719£-09 l.l6ZE-09 8.421E-10 6.404[-10 5.045[-10 4.084£-10 SSE 5.156£-08 1.743£-08 8.951£-09 5.496£-09 2.740£-09 l.662E-09 l.124E-09 8.l4ZE-l0 6.191£-10 4.878E-10 3.949£-10 DIRECTION FROM SITE s

SSW SW WSW w

WNW NW NNW N

NNE NE ENE E

ESE SE SSE DISTANCES IN MILES 5.00 7.50 10.00 15.00 20.00 25.00 30.00 35.00 40.00 45.00 50.'00 1.542£-10 7.556E-11 4.741£-11 2.396E-ll l.450E-ll 9.725£-12 6.968E-12 5.233E-12 4.068E-12 3.250E-12 2.653E-12 1.048£-10 S.l38E-11 3.224£-11 l.629E-ll 9.862E-12 6.613[-12 4.738E-12 3.558E-12 2.766E-12 Z.210E-12 1.804£-12 1.217E-10 5.96SE-11 3.743E-11 1.892E-ll l.145E-11 7.677E-12 5.SOlE-12 4.131E-12 3.212E-12 2.566E-12 2.094£-12 l.144E-l0 5.6DSE-ll 3.517E-ll l.178E-ll l.075E-ll 7.214£-12 5.l69E-12 3.882E-12 3.018E-12 Z.411E-12 l.968£-12 l.533E-10 7.SllE-11 4.713E-ll 2.38ZE-ll l.442E-ll 9.667E-12 6.927£-12 5.201E-12 4.044E-12 3.231E-12 2.637£-12 2.290E-10 1.122E-10 7.043E-11 3.560£-11 2.155E-11 l.445E-ll l.035E-11 7.773E-12 6.043£-12 4.827E-12 3.940E-12 Z.723E-10 1.335E-10 8.374E-ll 4.Z33E-ll Z.562E-ll l.718E-ll l.231E-11 9.242£-12 7.lBGE-12 5.740£-12 4.685E-l2 3.443E-10 l.687E-10 1.059E-10 5.352E-ll 3.239E-ll 2.172E-ll l.556E-ll l.169E~11 9.086E-12 7.258E-l2 5.924E-12 3.103E-10 l.5ZlE-10 9.542E-ll 4.8Z3E-ll 2.919E-ll l.957E-ll 1.4-02£-11 l.053E-ll 8.168E-12 6.540E-12 5.338E-12 1.858E-10 9.107E-ll 5.714E-11 2.888E-ll l.748E-ll l.172E-ll 8.399£-12 6.306E-12 4.903E-12 3.917E-12 3.197E-12 2.960E-10 l.451E-10 9.102E-11 4.&00E-11 2.784E-11 1.867E-ll l.338E-ll I.004E-ll 7.810E-12 6.239E-12 5.092£-12 2.190E-10 l.073E-10 6.733E-ll 3.403E-ll 2.DGOE-11 l.381E-ll 9.695£-12 7.430E-12 S,.777E-12 4.615E-12 3.767E-12 2.345E-10 l.149E-10 7.209E-ll 3.644E-ll 2.205E-ll 1.479£-11 l.060E-ll 7.956E-l2 6.1B6E-12 4.942E-12 4.033£-12

. 2:&43E-10 l.295E-10 8.126E-ll 4.107[-ll 2.486E-ll l.667E-ll l.194E-1J B.968E-12 6.973E-12 5.5/0E-12 4.546E-1Z 3.378£-10 l.656E-10 l.039E-10 5.251£-11 3.17BE-ll 2.131E-ll l.527E-ll 1.146£-11 B.914E-12 7.l20E-12 5.Bl2[-12 3.266E-10 l.601E-10 l.004E-lD 5.077E-ll 3.073E-ll 2.060E-11 l.476E~ll l.lDBE-11 B.619E-12 ~ 8B5l-12 5.619E-12 0,,,,

(./)

1-t "'O

-i )>

f'T1 r 1-t CJ (./)

0 E;

o

(./)

CD (Tl (Tl

~

(./)

n

)> :z CJ

(/l r

r c:

(Tl 0

n n

~

c: r I-'

~

(Tl l..O

)>

w

o 1-t 0

"'O

z s;;:

3: :z

)> -i

z c:

)>

r

USHRC COHPUTER CODE - XOQOOQ, VERSION 2.0 RUN DATE: 931116

  • tt*t PALISADES XOQDOQ62 ***** USING 01/01/BB - 12/31/92 MET DATA *'*'A GROUND LEVEL RELEASE - TOP OF CONTAINMENT BUILDlNG ttttttttAttttttttttttttt RELATIVE DEPOSITION PER UNIT AREA (H**-2) BY DOWNWIND SECTORS SEGHENT BOUNDARIES IN MILES 01RECTIOK

.5-1 1-2 2-3 3-4 4-5 5-10 10-20 20-30 30**40 40-50 0

FROM SITE s

4.391E-09 1.356[-09 5.398E-10 2.95DE-10

1. 875[-10 8.053E-ll 2.497E*ll 9.897E-12 5.285E-12 3.271E-12 Vl 1-i -u SSW 2.985E-D9 9.223£-10 3.670f-10
2. 006[-10 1.275£-10 5.475E-ll l.698E-ll B.729E-12 3.594E-J2 2.224E-12

-l )>

rn r SW 3.466£-09 1.071E-D9 4.261E-10 2.328£-10

1. 480[-10 6.357E-11 l.971E-11 7.813[-12" 4.172£-12 2.582E-l2 1-i Cl Vl WSW 3.257£-09 1.006[-09 4.004[-10 2.188£-10 l.391E-10 S.974E-11 1.852E-11 7.342E-12 3.921E-12 2.427E-1Z 0

)>

o Vl Cl w

4.364E-D9 1.348£-09 5.366E-10 2.93ZE-10 l.864E-10 8.005E-ll 2.482E-ll 9.838E-12 5.254£-12 3.252E-12 CD rn rn

-l Vl WNW 6.522f-09 2.015£-09 8.018E-10 4.381E-10 2.785E-10 1.196[-10 l.709E-ll l.470E-ll 7.BSlE-12 4.859E-12

)>

n w

co VI

)> :z:

..j:::>.

NW 7.755E-D9 2.396E-09 9.533[-10 5.210E-10 4.410E-ll

l. 748E-ll 9.335£-12 r

r c 3.311£-10

l. 422£-10 5.778E-12 rn 0

n n

I c r NNW 9.805£-09 3.029E-09 1.205£*09 6.587[-10 4.187E-10 l.796E-10
5. 576E-11 2.210£-11 1.180£-11 7.3D5f-12 s

~

l.O N

8.836£-09 2.730E-09 1.086(-09 5.936E-10

3. 773E-10 l.621E-10 5.DZ5E-ll l.992E-ll
1. 064£-11 6.583[-12

(....)

o 1-i NNE 5.Z9ZE-09 1.635E-09 6.505E-10 3.555E*l0 2.259[-10 9.705E-ll 3.0lOE-ll l.193E-ll 6.370£-12 3.943E-12 0 -u z ~

HE 8.428E*09 2.604[*09 1.036£-09 5.662[-10 3.599[-10 l.546E-10 4.794E-ll

1. 900E-ll 1.015[-11 fi.280E-12 3: z ENE 6.Z35E-D9 l.926E-09 7.665£-10 4.188E-10 2.662E-10 1.143£-10 3.546E-ll
1. 405E-ll 7.505E-12 4.645£-12

)> -l z c E

6.676£-09 2.063£-09 8.207E*l0 4.485E-10 2.85IE-l0 1.224£-10 3.797E-ll

1. 505E-11 8.036[-12 4.974E-l2

)>

r ESE 7.525£-09 2.325E-09 9.251E-10 5.055£-10 3.213£-10 1.380E-10 4.Z80E*ll

l. 696E-11 9.058E-1Z 5.606E-lZ SE 9.619E-09 2.97ZE-09 l.163[-09 6.462£-10 4.107[-10
1. 764E-10 5.471£-ll 2.168E-11 l.158E-11 7.167E-12 SSE 9.3DlE*09 2.873f-09 l.143E-09
6. 248E-10 3.971£-10 l.706f-10 5.290£-11 2.097£-11 1.llOE-11 6.930£-12 VENT AND BUILOJN6 PARAMETERS:

RELEASE HEIGHT (METERS) 58.10 REP. WIHD HEIGHT (METERS) 10.0 DIAMETER (METERS) 0.00 BUILDING HEIGHT (METERS) 58.1 EXIT VELOCITY (METERS) 0.00 BLOG.HlN.CRS.SEC.AREA (SQ.METERS) 2000.0 HEAT EMISSION RATE

. (CAL/SEC) 0.0 ALL GROUND LEVEL RELEASES.

  • '*l

PALISADES NUCLEAR PLANT OFFSITE DOSE CALCULATION MANUAL Revision 9 TABLE 1.4 1994 PALISADES LAND USE CENSUS Distance to the nearest residence. garden. dairy/beef cattle. and goat SECTOR RESIDENCE GARDEN BEEF CADLE DAIRY COW N

> 5 mi

> 5 mi

> 5 mi

> 5 mi NNE 1.1 mi

1. 6 mi

> 5 mi

> 5 mi NE

1. 2 mi
1. 2 mi

> 5 mi

> 5 mi ENE 1.3 mi

1. 5 mi
4. 0 mi
4. O mi E

1.0 mi 3.5 mi

3. 5 mi

> 5 mi ESE 1.0 mi 2.3 mi

5. 0 mi
4. 0 mi SE 1.0 mi 1.0 mi

> 5 mi

4. 3 mi SSE 0.7 mi
1. 6 mi
5. 0 mi

> 5 mi s

O.5 mi 1.5 mi

> 5 mi

> 5 mi SSW 0.7 mi

> 5 mi

> 5 mi

> 5 mi 35 in each sector.

GOAT

> 5 mi

> 5 mi 3.2 mi

> 5 mi

> 5 mi

> 5 mi

> 5 mi

5. 0 mi

> 5 mi

> 5 mi

PALISADES NUCLEAR PLANT OFFSITE DOSE CALCULATION MANUAL Revision 9 TABLE l.4a 1994 PALISADES LAND USE CENSUS Critical Receptor Items Distance Sector (Miles)

Location/Description Item

  • X/Q (sec/m3)

SSE 0.48 Site Boundary N/A 1.BOE-06 s

0.50 Residence. Palisades Park; Residence l.29E-06 1/2 mile West of 29th Avenue and Blue Star intersection NE

1. 2 L Swetay. Rt 3. Box 133 Garden 4.69E-07 Blue Star Hwy, East side E

3.5 C Mims. 26200 72nd St Beef 7.49E-08 72nd St and 26th Ave Cattle intersection SE 4.3 72401 36th Ave Dairy 6.09E-08 Cow NE 3.2 C Bernt Goat 1.12E-07 18019 M-140

  • Based on Palisades 5-year composite meteorological data. 1988-1992.

36

PALISADES NUCLEAR PLANT OFFSITE DOSE CALCULATION MANUAL Revision 9 TABLE 1. 5 DOSE FACTORS FOR SUBMERSION IN NOBLE GASES*

DFR1 DFY2 DFS1 DFB2 Kr-85m 1.17(+3) 3 1.23(+3)

1. 46( +3) 1.97(+3)

Kr-85 1.61(+1) 1.72(+1) 1.34(+3) 1.95(+3)

Kr-87 5.92(+3) 6.17(+3) 9.73(+3) 1.03(+4)

Kr-88

1. 47 ( +4)
1. 52( +4) 2.37(+3) 2.93(+3)

Kr-89 1.66(+4)

1. 73( +4)
1. 01( +4) 1.06(+4)

Xe-13lm 9.15(+1) 1.56(+2) 4.76(+2) 1.11(+3)

Xe-133m 2.51(+2) 3.27(+2) 9.94(+2)

1. 48( +3)

Xe-133 2.94(+2) 3.53(+2) 3.06(+2) 1.05(+3)

Xe-135m 3.12(+3) 3.36(+3) 7.11(+2) 7.39(+3)

Xe-135 1.81(+3) 1.92(+3) 1.86(+3) 2.46(+3)

Xe-137 1.42(+3) 1.51(+3)

1. 22( +4)
1. 27 ( +4)

Xe-138 8.83(+3)

9. 21( +3) 4.13(+3) 4.75(+3)

Ar-41 8.84(+3) 9.30(+3) 2.69(+3) 3.28(+3)

1.

mrem/y per µCi/m3

2.

mrad/y per µCi/m3

3.

1.17(+3) = l.17x 03

  • Dose factors for exposure to a semi-infinite cloud of noble gases:

Values were obtained from USNRC Regulatory Guide 1.109. Revision 1 (October 1977).

37

PALISADES NUCLEAR PLANT OFFSITE DOSE CALCULATION MANUAL Revision 9 TABLE 1.6 STABLE ELEMENT TRANSFER DATA Fm - MILK (COW)

Fm - MILK (GOAT)

F - MEAT B.

ELEMENT (OAYS/L)

(OAYS/U CDAYS/KG)

CVEG/~OIU H

l.OE-02

1. 7E-01 1.2E-02.

4.8E-OO c

1.2E-02 1.0E-01 3.lE-02 5.5E-OO Na 4.0E-02 4.0E-02 3.0E-02 5.2E-02 p

2.5E-02 2.5E-01 4.6E-02 1.lE-00 Cr 2.2E-03 2.2E-03 2.4E-03 2.5E-04 Mn 2.5E-04 2.5E-04 8.0E-04 2.9E-02 Fe 1.2E-03 1.3E-04 4.0E-02 6.6E-04 Co l.OE-03

1. OE-03
1. 3E-02 9.4E-03 Ni 6.7E-03 6.7E-03 5.3E-02
1. 9E-02 Cu 1.4E-02 1.3E-02 8.0E-03
1. 2E-Ol Zn 3.9E-02 3.9E-02 3.0E-02 4.0E-01 Rb 3.0E-02 3.0E-02 3.lE-02 1.3E-Ol Sr 8.0E-04 1.4E-02 6.0E-04
1. 7E-02 y
1. OE-05 1.0E-05 4.6E-03 2.6E-03 Zr 5.0E-06 5.0E-06 3.4E-02
1. 7E-04
  • Nb 2.5E-03 2.5E-03 2.8E-Ol 9.4E-03 Mo 7.5E-03 7.5E-03 8.0E-03 l.2E-Ol Tc 2.5E-02 2.5E-02 4.0E-01 2.5E-01 Ru
1. OE-06 1.0E-06 4.0E-01 5.0E-02 Rh 1.0E-02 l.OE-02
1. 5E-03
1. 3E+Ol Ag 5.0E-02 5.0E-02 1.7E-02
1. 5E-01 Te l.OE-03
1. OE-03 7.7E-02 1.3E-OO I

6.0E-03 6.0E-02 2.9E-03 2.0E-02*

Cs 1.2E-02 3.0E-01 4.0E-03

1. OE-02 Ba 4.0E-04 4.0E-04 3.2E-03 5.0E-03 La 5.0E-06 5.0E-06 2.0E-04 2.5E-03 Ce
1. OE-04 l.OE-04 1.2E-03 2.5E-03 Pr 5.0E-06 5.0E-06 4.7E-03 2.5E-03 Nd 5.0E-06 5.0E-06 3.3E-03 2.4E-03 w

5.0E-04 5.0E-04 l.3E-03 l.8E-02 Np 5.0E-06 5.0E-06 2.0E-04 2.5E-03 38

PALISADES NUCLEAR PLANT OFFSITE DOSE CALCULATION MANUAL Revision 9 TABLE 1.7 INFANT INHALATION DOSE COMMITMENT FACTORS CMREM/50Y PER PCI INHALED IN FIRST YR)

ISOTOPE BONE LIVER TOTAL BODY THYROID KIDNEY LUNG GI*LLI H3*

0.

4.62E-07 4.62E-07 4.62E-07 4.62E-07 4.62E-07 4.62E-07 BElO 9.49E-04 l.25E-04 2.65E-05

0.
0.

l.49E-03 l.73E-05 Cl4 l.89E-05 3.79E-06 3.79E-06 3.79E-06 3.79E-06 3.79E-06 3.79E-06 Nl3 4.39E-08 4.39E-08 4.39E-08 4.39E-08 4.39E-08 4.39E-08 4.39E-08 Fl8 3.92E-06 0.

3.33E-07

0.
0.
0.

6.lOE-07 NA22 7.37E-05 7.37E-05 7.37E-05 7.37E-05 7.37E-05 7.37E-05 7.37E-05 NA24 7.54E-06 7.54E-06 7.54E-06 7.54E-06 7.54E-06 7.54E-06 7.54E-06 P32 l.45E-03 8.03E-05 5.53E-05

0.
0.
0.

l.lSE-05 AR39

0.
0.
0.
0.
0.

l.OOE-08 0.

AR41

0.
0.
0.
0.
0.

3.14E-08 0.

CA41 7.48E-05 0.

8.16E-06.

0.
0.

6.94E-02 2.96E-07 SC46 3.75E-04 5.41E-04 l.69E-04

0.

3.56E-04 0.

2.19E-05 CR51

0.
0.

6.39E-08 4.llE-08 9.45E-09 9.17E-06 2.55E-07 MN54

0.

l.81E-05 3.56E-06

0.

3.56E-06 7.14E-04 5.04E-06 MN56

0.

l.lOE-09 l.58E-10

0.

7.86E-10 8.95E-06 5.12E-05 FE55 l.41E-05 8.39E-06 2.38E-06

0.
0.

6.21E-05 7.82E-07 FE59 9.69E-06 l.68E-05 6.77E-06

0.
0.

7.25E-04 l.77E-05 C057

0.

4.65E-07 4.SBE-07

0.
0.

2.71E-04 3.47E-06 C058

0.

8.71E-07 l.30E-06

0.
0.

5.SSE-04 7.95E-06 C060

0.

5.73E-06 8.41E-06

0.
0.

3.22E-03 2.28E-05 NI59 l.BlE-05 5.44E-06 3.lOE-06

0.
0.

5.48E-05 6.34E-07 NI63 2.42E-04 l.46E-05 8.29E-06

0.
0.

l.49E-04 l.73E-06 NI65 l.71E-09 2.03E-10 8.79E-ll

0.
0.

5.BOE-06 3.58E-05 CU64

0.

l.34E-09 5.53E-10

0.

2.84E-09 6.64E-06 l.07E-05 ZN65 l.38E-05 4.47E-05 2.22E-05

0.

2.32E-05 4.62E-04 3.67E-05 ZN69M+D 8.98E-09 l.84E-08 l.67E-09

0.

7.45E-09 l.91E-05 2.92E-05 ZN69 3.85E-ll 6.91E-ll 5.13E-12

0.

2.87E-ll 1.05E-06 9.44E-06 SE79

0.

2.25E-06 4.20E-07

0.

2.47E-06 2.99E-04 3.46E-06 BR82

0.
0.

9.49E-06

0.
0.
0.
0.

BR83+0

0.
0.

2.72E-07

0.
0.
0.
0.

BR84

0.
0.

2.86E-07

0.
0.
0.
0.

BR85

0.
0.

1.46E-08

0.
0.
0.
0.

KR83M

0.
0.
0.
0.
0.

2.50E-09 0.

KR85M

0.
0.
0.
0.
0.

l.31E-08 0.

KR85

0.
0.
0.
0.
0.

1.16E-08 0.

KR87

0.
0.
0.
0.
0.

6.59E-08 0.

KRBB+D

0.
0.
0.
0.
0.

1.38E-07 0.

KR89

0.
0.
0.
0.
0.

8.67E-08 0.

RB86

0.

l.36E-04 6.30E-05

0.
0.
0.

2.17E-06 RB87

0.

7.llE-05 2.64E-05

0.
0.
0.

2.99E-07 RBBB

0.

3.98E-07 2.05E-07

0.
0.
0.

2.42E-07 RB89+0

0.

2.29E-07 l.47E-07

0.
0.
0.

4.87E-08 SR89+0 2.84E-04 0.

8.15E-06

0.
0.

l.45E-03 4.57E-05 SR90+0 2.92E-02 0.

l.85E-03

0.
0.

8.03E-03 9.36E-05 SR91+0 6.83E-08 0.

2.47E-09

0.
0.

3.76E-05 5.24E-05 SR92+D 7.50E-09 0.

2.79E-10

0.
0.

l.70E-05 l.OOE-04 Includes a 50% increase to account for percutaneous transpiration.

39

PALISADES NUCLEAR PLANT OFFSITE DOSE CALCULATION MANUAL Revision 9 TABLE 1.7 (continued)

. INFANT INHALATION DOSE COMMITMENT FACTORS (MREM/50Y PER PCI INHALED IN FIRST YR)

ISOTOPE BONE LIVER TOTAL BODY THYROID KIDNEY LUNG GI*LLI Y90 2.35E-06 0.

6.30E-08

0.
0.

l.92E-04 7.43E-05 Y91M+D 2.91E-10

0.

9.90E-12

0.
0.

1.99E-06 1.68E-06 Y91 4.20E-04 0.

1.12E-05

0.
0.

1.75E-03 5.02E-05 Y92 l.17E-08 0.

3.29E-10

0.
0.

1.75E-05 9.04E-05 Y93 l.07E-07

0.

2.91E-09

0.
0.

5.46E-05 1.19E-04 ZR93+0 2.24E-04 9.51E-05 6.18E-05

0.

3.19E-04 l.37E-03 1.48E-05 ZR95+D 8.24E-05 1.99E-05 1.45E-05

0.

2.22E-05 l.25E-03 1.55E-05 ZR97+0 1.07E-07 l.83E-08 8.36E-09

0.

1.85E-08 7.88E-05 l.OOE-04 NB93M l.38E-04 3.59E-05 l.15E-05

0.

3.68E-05 2.09E-04 2.47E-06 NB95 l.12E~05 4.59E-06 2.70E-06

0.

3.37E-06 3.42E-04 9.05E-06 NB97 2.44E-10 5.21E-ll l.88E-11

0.

4.07E-11 2.37E-06 1.92E-05 M093

0.

6.46E-06 2.22E-07

0.

l.54E-06 3.40E-04 3.76E-06 M099+0

0.

1.18E-07 2.31E-08

0.

l.89E-07 9.63E-05 3.48E-05 TC99M 9.98E-13 2.06E-12 2.66E-ll

0.

2.22E-11 5.79E-07 1.45E-06 TC99 2.09E-07 2.68E-07 8.85E-08

0.

2.49E-06 6.77E-04 7.82E-06 TClOl 4.65E-14 5.88E-14 5.SOE-13

0.

6.99E-13 4.17E-07 6.03E-07 RU103+D l.44E-06 0.

4.85E-07

0.

3.03E-06 3.94E-04 l.15E-05 RU105+0 8.74E-10 0.

2.93E-10

0.

6.42E-10 l.12E-05 3.46E-05 RU106+0 6.20E-05 0.

7.77E-06

0.

7.61E-05 8.26E-03 l.17E-04 RH105 8.26E-09 5.41E-09 3.63E-09

0.

l.50E-08 2.08E-05 l.37E-05 PD107

0.

4.92E-07 4.llE-08

0.

2.75E-06 6.34E-05 7.33E-07 PD109

0.

3.92E-09 l.05E-09

0.

l.28E-08 l.68E-05 2.85E-05 AGllOM+D 7.13E-06 5.16E-06 3.57E-06

0.

7.80E-06 2.62E-03 2.36E-05 AGlll 3.75E-07 l.45E-07 7.75E-08

0.

3.05E-07 2.06E-04 3.02E-05 CD113M

0.

6.67E-04 2.64E-05

0.

5.80E-04 l.40E-03 l.65E-05 CD115M

0.

l.73E-04 6.19E-06

0.

9.41E-05 l.47E-03 5.02E-05 SN123 2.09E-04 4.21E-06 7.28E-06 4.27E-06 0.

2.22E-03 4.0SE-05 SN125+0 1.0lE-05 2.51E-07 6.00E-07 2.47E-07

0.

6.43E-04 7.26E-05 SN126+D 8.30E-04 l.44E-05 3.52E-05 3.84E-06 0.

4.93E-03 l.65E-05 SB124 2.71E-05 3.97E-07 8.56E-06 7.18E-08 0.

l.89E-03 4.22E-05 SB125+D 3.69E-05 3.41E-07 7.78E-06 4.45E-08 0.

l.17E-03 l.05E-05 SB126 3.0SE-06 6.0lE-08 l.llE-06 2.35E-08 0.

6.88E-04 5.33E-05 SB127 2.82E-07 5.04E-09 8.76E-08 3.60E-09 0.

l.54E-04 3.78E-05 TE125M 3.40E-06 l.42E-06 4.70E-07 l.16E-06 0.

3.19E-04 9.22E-06 TE127M+D l.19E-05 4.93E-06 l.48E-06 3.48E-06 2.68E-05 9.37E-04 l.95E-05 TE127 l.59E-09 6.81E-10 3.49E-10 l.32E-09 3.47E-09 7.39E-06 l.74E-05 TE129M+D l.OlE-05 4.35E-06 l.59E-06 3.91E-06 2.27E-05 l.20E-03 4.93E-05 TE129 5.63E-ll 2.48E-11 l.34E-11 4.82E-11 1.25E-10 2.14E-06 l.88E-05 TE131M+D 7.62E-08 3.93E-08 2.59E-08 6.38E-08 1.89E-07 1.42E-04 8.51E-05 TE131+0 1.24E-11 5.87E-12 3.57E-12 1.13E-ll 2.85E-11 1.47E-06 5.87E-06 TE132+D 2.66E-07 1.69E-07 1.26E-07 1.99E-07 7.39E-07 2.43E-04 3.15E-05 TE133M+D 6.13E-11 3.59E-11 2.74E-11 5.52E-ll l.72E-10 3.92E-06 l.59E-05 TE134+0 3.18E-11 2.04E-ll l.68E-ll 2.91E-ll 9.59E-11 2.93E-06 2.53E-06 1129 2.16E-05 l.59E~05 l.16E-05 l.04E-02 1.88E-05 0.

2.12E-07 1130 4.54E-06 9.91E-06 3.98E-06 1.14E-03 1.09E-05 0.

l.42E-06 1131+0 2.71E-05 3.17E-05 l.40E-05 l.06E-02 3.70E-05 0.

7.56E-07

  • 40

PALISADES NUCLEAR PLANT OFFSITE DOSE CALCULATION MANUAL Revision 9 TABLE 1.7 (continued)

INFANT INHALATION DOSE COMMITMENT FACTORS CMREM/50Y PER PCI INHALED IN FIRST YR)

ISOTOPE BONE LIVER TOTAL BODY THYROID KIDNEY LUNG GI-LLI 1132 1.21E-06 2.53E-06 8.99E-07 1.21E-04 2.82E-06 0.

1.36E-06 1133+0 9.46E-06 1.37E-05 4.00E-06 2.54E-03 1.60E-05 0.

1.54E-06 1134 6.58E-07 1.34E-06 4.75E-07 3.18E-05 1.49E-06 0.

9.21E-07 1135+0 2.76E-06 5.43E-06 l.98E-06 4.97E-04 6.05E-06 0.

1.31E-06 XE131M

0.
0.
0.
0.
0.

6.77E-09 0.

XE133M

0.
0.
0.
0.
0.

8.89E-09 0.

XE133

0.
0.
0.
0.
0.

7.41E-09 0.

XE135M

0.
0.
0.
0.
0.

8.05E-09 0.

XE135

0.
0.
0.
0.
0.

1.80E-08 0.

XE137

0.
0.
0.
0.
0.

8.30E-08 0.

XE138+0

0.
0.
0.
0.
0.

9.78E-08 0.

CS134M+O 1.32E-07 2.lOE-07 1.llE-07

0.

8.50E-08 2.00E-08 1.16E-07 CS134 2.83E-04 5.02E-04 5.32E-05

0.

l.36E-04 5.69E-05 9.53E-07 CS135 l.OOE~04 8.66E-05 4.73E-06

0.

2.58E-05 l.OlE-05 2.18E-07 CS136 3.45E-05 9.61E-05 3.78E-05

0.

4.03E-05 8.40E-06 1.02E-06 CS137+0 3.92E-04 4.37E-04 3.25E-05

0.

1.23E-04 5.09E-05 9.53E-07 CS138 3.61E-07 5.58E-07 2.84E-07

0.

2.93E-07 4.67E-08 6.26E-07 CS139+0 2.32E-07 3.03E-07 1.22E-07

0.

1.65E-07 2.53E-08 1.33E-08 BA139 1.06E~09 7.03E-13 3.07E-11

0.

4.23E-13 4.25E-06 3.64E-05 BA140+0 4.00E-05 4.00E-08 2.07E-06

0.

9.59E-09 1.14E-03 2.74E-05 BA141+0 1.12E-10 7.70E-14 3.55E-12

0.

4.64E-14 2.12E-06 3.39E-06 BA142+0 2.84E-11 2.36E-14 1.40E-12

0.

1.36E-14 1.llE-06 4.95E-07 LA140 3.61E-07 1.43E-07 3.68E-08

0.
0.

1.20E-04 6.06E-05 LA141 4.85E-09 1.40E-09 2.45E-10

0.
0.

1.22E-05 5.96E-05 LA142 7.36E-10 2.69E-10 6.46E-11

0.
0.

5.87E-06 4.25E-05 CE141 1.98E-05 1.19E-05 1.42E-06

0.

3.75E-06 3.69E-04 l.54E-05 CE143+0 2.09E-07 1.38E-07 1.58E-08

0.

4.03E-08 8.30E-05 3.55E-05 CE144+0 2.28E-03 8.65E-04 1.26E-04

0.

3.84E-04 7.03E-03 1.06E-04 PR143 1.00E-05 3.74E-06 4.99E-07

0.

1.41E-06 3.09E-04 2.66E-05 PR144 3.42E-11 1.32E-11 1.72E-12

0.

4.80E-12 1.15E-06 3.06E-06 N0147+0 5.67E-06 5.81E-06 3.57E-07

0.

2.25E-06 2.30E-04 2.23E-05 PM147 3.91E-04 3.07E-05 1.56E-05

0.

4.93E-05 4.55E-04 5.75E-06 PM148M+O 5.00E-05 1.24E-05 9.94E-06

0.

1.45E-05 1.22E-03 3.37E-05 PM148 3.34E-06 4.82E-07 2.44E-07

0.

5.76E-07 3.20E-04 6.04E-05 PM149 3.lOE-07 4.08E-08 1.78E-08

0.

4.96E-08 6.50E-05 3.0lE-05 PM151 7.52E-08 1.lOE-08 5.55E-09

0.

1.30E-08 3.25E-05 2.58E-05 SM151 3.38E-04 6.45E-05 1.63E-05

0.

5.24E-05 2.98E-04 3.46E-06 SM153 1.53E-07 1.18E-07 9.06E-09

0.

2.47E-08 3.70E-05 1.93E-05 EU152 7.83E-04 1.77E-04 1.72E-04

0.

5.94E-04 1.48E-03 9.88E-06 EU154 2.96E-03 3.46E-04 2.45E-04

0.

1.14E-03 3.05E-03 2.84E-05 EU155 5.97E-04 5.72E-05 3.46E-05

0.

1.58E-04 5.20E-04 5.19E-05 EU156 1.56E-05 9.59E-06 1.54E-06

0.

4.48E-06 6.12E-04 4.14E-05 TB160 1.12E-04 0.

1.40E-05

0.

3.20E-05 1.llE-03 2.14E-05 H0166M 1.45E-03 3.07E-04 2.51E-04

0.

4.22E-04 2.05E-03 1.65E-05 W181 4.86E-08 l.46E-08 1.67E-09

0.
0.

1.33E-05 2.63E-07 W185 l.57E-06 4.83E-07 5.58E-08

0.
0.

4.48E-04 l.12E-05 W187 9.26E-09 6.44E-09 2.23E-09

0.
0.

2.83E-05 2.54E-05 41

PALISADES NUCLEAR PLANT OFFSITE DOSE CALCULATION MANUAL Revision 9 TABLE 1.7 (continued)

INFANT INHALATION DOSE COMMITMENT FACTORS (MREM/50Y PER PCI INHALED IN FIRST YR)

ISOTOPE BONE LIVER TOTAL BODY THYROID KIDNEY LUNG GI-LLI PB210+D 8.62E-02 2.02E-02 3.43E-03

0.

6.85E-02 1.76E-01 3.79E-05 BI210+D

0.

1.33E-05 1.18E-06

0.

1.03E-04 9.96E-03 3.27E-05 P0210 2.98E-03 5.63E-03 7.12E-04

0.

1.30E-02 2.40E-01 4.36E-05 RN222+D

0.
0.
0.
0.
0.

9.BBE-06 0.

RA223+D 1.56E-03 2.26E-06 3.12E-04

0.

4.16E-05 2.25E-01 3.04E-04 RA224+D 1.77E-04 4.00E-07 3.54E-05

0.

7.30E-06 7.91E-02 3.42E-04 RA225+D 2.57E-03 2.BBE-06 5.13E-04

0.

5.31E-05 2.57E-01 2.87E-04 RA226+D 2.48E-01 1.46E-05 2.05E-01

0.

2.94E-04 7.83E-01 3.05E-04 RA228+D 1.60E-01 7.61E-06 1.BOE-01

0.

1.53E-04 1.09E-OO 5.19E-05 AC225 3.69E-03 4.72E-03 2.48E-04

0.

3.49E-04 1.96E-01 2.71E-04 AC227+D 5.29E+OO 8.76E-01 3.28E-01

0.

1.86E-01 1.62E+OO 5.27E-05 TH227+D 1.82E-03 3.03E-05 5.24E-05

0.

1.13E-04 3.27E-01 3.53E-04 TH228+D 8.46E-01 1.lOE-02 2.86E-02

0.

5.61E-02 4.65E+OO 3.62E-04 TH229 1.34E+Ol 1.82E-01 6.62E-Ol

0.

8.99E-01 1.22E+Ol 3.29E-04 TH230 3.46E+OO 1.79E-01 9.65E-02

0.

8.82E-01 2.18E+OO 3.87E-05 TH232+D 3.86E+OO 1.53E-Ol 2.29E-01

0.

7.54E-01 2.09E+OO 3.29E-05 TH234 1.33E-05 7.17E-07 3.84E-07

0.

2.70E-06 l.62E-03 7.40E-05 PA23l+D 9.lOE+OO 3.00E-01 3.62E-01

0.

1.62E+OO 3.85E-01 4.61E-05 PA233 6.84E-06 1.32E-06 1.19E-06

0.

3.68E-06 2.19E-04 9.04E-06 U232+D 2.57E-01

0.

2.13E-02

0.

2.40E-02 l.49E+OO 4.36E-05 U233+D 5.44E-02 0.

3.83E-03

0.

1.09E-02 3.56E-01 4.03E-05 U234 5.22E-02 0.

3.75E-03

0.

1.07E-02 3.49E-01 3.95E-05 U235+D 5.0lE-02 0.

3.52E-03

0.

1.0lE-02 3.28E-01 5.02E-05 U236 5.0lE-02 0.

3.60E-03

0.

1.03E-02 3.35E-01 3.71E-05 U237 3.25E-07 0.

8.65E-08

0.

8.0BE-07 9.13E-05 1.31E-05 U238+D 4.79E-02 0.

3.29E-03

0.

9.40E-03 3.06E-01 3.54E-05 NP237+D 3.03E+OO 2.32E-01 1.26E-01

0.

7.69E-01 3.49E-01 5.lOE-05 NP238 2.67E-06 6.73E-08 4.16E-08

0.

1.47E-07 9.19E-05 2.58E-05 NP239 2.65E-07 2.37E-08 1.34E-08

0.

4.73E-08 4.25E-05 1.78E-05 PU238 5.02E+OO 6.33E-01 1.27E-01

0.

4.64E-01 9.03E-01 4.69E-05 PU239 5.50E+OO 6.72E-01 1.34E-01

0.

4.95E-01 8.47E-01 4.28E-05 PU240 6.49E+OO 6.71E-01 1.34E-01

0.

4.94E-01 8.47E-01 4.36E-05 PU241+D l.55E-01 6.69E-03 3.llE-03

0.

1.15E-02 7.62E-04 8.97E-07 PU242 5.09E+OO 6.47E-01 1.29E-01

0.

4.77E-01 8.15E-01 4.20E-05 PU244 5.95E+OO 7.40E-01 1.48E-01

0.

5.46E-01 9.33E-01 6.26E-05 AM241 1.84E+OO 8.44E~Ol 1.31E-01

0.

7.94E-Ol 4.06E-01 4.78E-05 AM242M l.90E+OO 8.24E-01 1.35E-01

0.

8.03E-01 1.64E-Ol 6.0lE-05 AM243 1.82E+OO 8.lOE-01 l.27E-01

0.

7.72E-01 3.85E-01 5.60E-05 CM242 8.58E-02 7.44E-02 5.70E-03

0.

1.69E-02 2.97E-01 5.lOE-05 CM243 l.73E+OO 7.94E-01 1.06E-01

0.

3.91E-Ol 4.24E-Ol 5.02E-05 CM244 1.43E+OO 7.04E-01 8.89E-02

0.

3.21E-01 4.08E-01 4.86E-05 CM245 2.26E+OO 8.BOE-01 1.36E-01

0.

5.23E-01 3.92E-01 4.53E-05 CM246 2.24E+OO 8.79E-01 1.36E-01

0.

5.23E-01 3.99E-01 4.45E-05 CM247+D 2.18E+OO 8.64E-01 1.33E-01

0.

5.15E-01 3.92E-01 5.85E-05 CM248 1.82E+Ol 7.12E+OO 1.lOE+OO

0.

4.24E+OO 3.23E+OO 9.43E-04 CF252 4.26E+OO

0.

1.0lE-01

0.
0.

1.37E+OO l.85E-04

  • 42

PALISADES NUCLEAR PLANT OFFSITE DOSE CALCULATION MANUAL Revision 9 TABLE 1.7 (contd)

CHILO. INHALATION DOSE COMMITMENT FACTORS CMREM/50Y PER PC! INHALED IN FIRST YR)

ISOTOPE BONE

- LIVER TOTAL BODY THYROID KIDNEY LUNG GI-LL!

HJ*

0.

3.04E-07 3.04E-07 3.04E-07 3.04E-07 3.04E-07 3.04E-07 BElO 8.43E-04 9.83E-OS 2.12E-OS 0..

0.

7.41E-04 l.72E-OS Cl4 9.?0E-06 l.82E-06 l.82E-06 l.82E-06 l.82E-06 l.82E-06 l.82E-06 Nl3 2.33E-08 2.33E-08 2.33E-08 2.33E-08 2.33E-08 2.33E-08 2.33E-08 Fl8 l.88E-06 0.

l.BSE-07

0.
0.
0.

3.37E-07 NA22 4.41E-OS 4.41E-OS 4.41E-OS 4.41E-OS 4.41E-OS 4.41E-OS 4.41E-OS NA24 4.3SE-06 4.3SE-06 4.3SE-06 4.3SE-06 4.3SE-06 4.3SE-06 4.3SE-06 P32 7.04E-04 3.09E-OS 2.67E-OS

0.
0.
0.

1.14E-OS AR39

0.
0.
0.
0.
0.

4.89E-09 0.

AR41

0.
0.
0.
0.
0.

1.68E-08 0.

CA41 7.06E-OS 0.

7.?0E-06

0.
0.

7.21E-02 2.94E-07 SC46 1.97E-04 2.?0E-04 1.04E-04

0.

2.39E-04 0.

2.4SE-OS CRSl

0.
0.

4.l?E-08 2.31E-08 6.S?E-09 4.S9E-06 2.93E-07 MNS4

0.

1.16E-OS 2.S?E-06

0.

2.71E-06 4.26E-04 6.19E-06 MNS6

0.

4.48E-10 8.43E-11

0.

4.S2E-10 3.SSE-06 3.33E-OS FESS 1.28E-OS 6.BOE-06 2.lOE-06

0.
0.

3.00E-OS 7.?SE-07 FES9 S.S9E-06 9.04E-06 4.SlE-06

0.
0.

3.43E-04 1.91E-OS COS?

0.

2.44E-07 2.88E-07

0.
0.

1.37E-04 3.SSE-06 COS8

0.

4.79E-07 8.SSE-07

0.
0.

2.99E-04 9.29E-06 C060

0.

3.SSE-06 6.12E-06

0.
0.

1.91E-03 2.60E-OS NIS9 1.66E-OS 4.67E-06 2.83E-06

0.
0.

2.73E-OS 6.29E-07 NI63 2.22E-04 1.2SE-OS 7.S6E-06

0.
0.

7.43E-OS 1.71E-06 NI6S 8.08E-10 7.99E-11 4.44E-11

0.
0.

2.21E-06 2.27E-OS CU64

0.

S.39E-10 2.90E-10

0.

1.63E-09 2.S9E-06 9.92E-06 ZN6S 1.lSE-OS 3.06E-OS 1.90E-OS

0.

1.93E-OS 2.69E-04 4.41E-06 ZN69M+D 4.26E-09 7.28E-09 8.S9E-10

0.

4.22E-09 7.36E-06 2.71E-OS ZN69 1.SlE-11 2.61E-11 2.41E-12

0.

1.S8E-11 3.84E-07 2.?SE-06 SE79

0.

1.23E-06 2.60E-07

0.

1.71E-06 1.49E-04 3.43E-06 BR82

0.
0.

S.66E-06

0.
0.
0.
0.

BR83+0

0.
0.

1.28E-07

0.
0.
0.
0.

BR84

0.
0.

1.48E-07

0.
0.
0.
0.

BRBS

0.
0.

6.84E-09

0.
0.
0.
0.

KR83M

0.
0.
0.
0.
0.

1.22E-09 0.

KRBSM

0.
0.
0.
0.
0.

6.S8E-09 0.

KRSS

0.
0.
0.
0.
0.

S.66E-09 0.

KR87

0.
0.
0.
0.
0.

3.38E-08 0.

KR88+0 0.

0.

0.

0.

0.

6. 99E -08 0.

KR89

0.
0.
0.
0.
0.

4.SSE-08 0.

RB86

0.

S.36E-OS 3.09E-OS

0.
0.
0.

2.16E-06 RB87

0.

3.16E-OS 1.37E-OS

0.
0.
0.

2.96E-07 RB88

0.

1.S2E-07 9.90E-08

0.
0.
0.

4.66E-09 RB89+0

0.

9.33E-08 7.83E-08

0.
0.
0.

S.llE-10 SR89+0 1.62E-04 0.

4.66E-06

0.
0.

S.83E-04 4.S2E-OS SR90+0 2.73E-02 0.

1.74E-03

0.
0.

3.99E-03 9.28E-OS SR91+0 3.28E-08 0.

1.24E-09

0.
0.

1.44E-05 4.70E-OS SR92+D 3.54E-09 0.

1.42E-10

0.
0.

6.49E-06 6.SSE-OS

  • Includes a SO% increase to account for percutaneous transpiration.

43

PALISADES NUCLEAR PLANT OFFSITE DOSE CALCULATION MANUAL Revision 9 TABLE 1.7 (contd)

CHILD INHALATION DOSE COMMITMENT FACTORS (MREM/SOY PER PCI INHALED IN FIRST YR)

ISOTOPE BONE LIVER TOTAL BODY THYROID KIDNEY LUNG GI-LL!

Y90 l.llE-06 0.

2.99E-08

0.
0.

7.07E-05 7.24E-05 Y91M+D l.37E-10 0.

4.98E-12

0.
0.

7.60E-07 4.64E-07 Y91 2.47E-04 0.

6.59E-06

0.
0.

7.lOE-04 4.97E-05 Y92 5.50E-09

0.

l.57E-10

0.
0.

6.46E-06 6.46E-05 Y93 5.04E-08 0.

l.38E-09

0.
0.

2.0lE-05 l.05E-04 ZR93+0 2.07E-04 7.80E-05 5.55E-05

0.

3.00E-04 7.lOE-04. l.47E-05 ZR95+0 5.13E-05 l.13E-05 l.OOE-05

0.

1.61E-05 6.03E-04 l.65E-05 ZR97+0 5.07E-08 7.34E-09 4.32E-09

0.

l.05E-08 3.06E-05 9.49E-05 NB93M l.27E-04 3.17E-05 l.04E-05

0.

3.44E-05 l.04E-04 2.45E-06 NB95 6.35E-06 2.48E-06 l.77E-06

0.

2.33E-06 l.66E-04 l.OOE-05 NB97 l.16E-10 2.08E-ll 9.74E-12

0.

2.31E-ll 9.23E-07 7.52E-06 M093

0.

3.76E-06 1.35E-07

0.

l.06E-06 l.70E-04 3.78E-06 M099+0

0.

4.66E-08 l.15E-08

0.

l.06E-07 3.66E-05 3.42E-05 TC99M 4.81E-13 9.41E-13 l.56E-ll

0.

l.37E-11 2.57E-07 l.30E-06 TC99 l.34E-07 l.49E-07 5.35E-08

0.

1.75E-06 3.37E-04 7.75E-06 TClOl 2.19E-14 2.30E-14 2.91E-13

0.

3.92E-13 l.58E-07 4.41E-09 RU103+0 7.55E-07

0.

2.90E-07

0.

l.90E-06 l.79E-04 l.21E-05 RU105+0 4.13E-10

0.

l.50E-10

0.

3.63E-10 4.30E-06 2.69E-05 RU106+0 3.68E-05 0.

4.57E-06

0.

4.97E-05 3.87E-03 l.16E-04 RH105 3.91E-09 2.lOE-09 1.79E-09

0.

8.39E-09 7.82E-06 1.33E-05 PD107

0.

2.65E-07 2.51E-08

0.

l.97E-06 3.16E-05 7.26E-07 P0109

0.

l.48E-09 4.95E-10

0.

7.06E-09 6.16E-06 2.59E-05 AGllOM+D 4.56E-06 3.08E-06 2.47E-06

0.

5.74E-06 1.48E-03 2.71E-05 AGlll l.81E-07 5.68E-08 3.75E-08

0.

l.71E-07 7.73E-05 2.98E-05 CD113M

0.

4.93E-04 2.12E-05

0.

5.13E-04 6.94E-04 l.63E-05 C0115M

0.

7.88E-05 3.39E-06

0.

5.93E-05 5.86E-04 4.97E-05 SN123

. l.29E-04 2.14E-06 4.19E-06 2.27E-06 0.

9.59E-04 4.05E-05 SN125+0 4.95E-06 9.94E-08 2.95E-07 l.03E-07 0.

. 2.43E-04 7.17E-05 SN126+0 6.23E-04 1.04E-05 2.36E-05 2.84E-06 0.

3.02E-03 l.63E-05 SB124 l.55E-05 2.00E-07 5.41E-06 3.41E-08 0.

8.76E-04 4.43E-05 SB125+0 2.66E-05 2.05E-07 5.59E-06 2.46E-08 0.

6.27E-04 1.09E-05 SB126 1.72E-06 2.62E-08 6.16E-07 l.OOE-08 0.

2.86E-04 5.67E-05 SB127 l.36E-07. 2.09E-09 4.70E-08 l.51E-09 0.

6.17E-05 3.82E-05 TE125M 1.82E-06 6.29E-07 2.47E-07 5.20E-07 0.

1.29E-04 9.13E-06 TE127M+O 6.72E-06 2.31E-06 8.16E-07 1.64E-06 1.72E-05 4.00E-04 1.93E-05 TE127 7.49E-10 2.57E-10 1.65E-10 5.30E-10 1.91E-09 2.71E-06 1.52E-05 TE129M+O 5.19E-06 1.85E-06 8.22E~07 1.71E-06 1.36E-05 4.76E-04 4.91E-05 TE129 2.64E-11 9.45E-12 6.44E-12 l.93E-ll 6.94E-ll 7.93E-07 6.89E-06 TE131M+D 3.63E-08 l.60E-08 l.37E-08 2.64E-08 l.08E-07 5.56E-05 8.32E-05 TE131+0 5.87E-12 2.28E-12 1.78E-12 4.59E-12 1.59E-11 5.55E-07 3.60E~07 TE132+0 l.30E-07 7.36E-08 7.12E~08 8.58E-08 4.79E-07 1.02E-04 3.72E-05 TE133M+D 2.93E-11 1.51E-11 1.50E-11 2.32E-11 1.0lE-10 1.60E-06 4.77E-06 TE134+0 l.53E-11 8.81E-12 9.40E-12 1.24E-11 5.71E-11 l.23E-06 4.87E-07 1129 1.05E-05 6.40E-06 5.71E-06 4.28E-03 1.08E-05 0.

2.15E-07 1130 2.21E-06 4.43E-06 2.28E-06 4.99E-04 6.61E-06 0.

1.38E-06 1131+0 1.30E-05 1.30E-05 7.37E-06 4.39E-03 2.13E-05 0.

7.68E-07 44

PALISADES NUCLEAR PLANT OFFSITE DOSE CALCULATION MANUAL Revision 9 TABLE 1.7 (contd)

CHILD INHALATION DOSE 'COMMITMENT FACTORS (MREM/50Y PER PCI INHALED IN FIRST YR)

ISOTOPE BONE LIVER TOTAL BODY THYROID KIDNEY LUNG GI-LLI 1132 5.72E-07 1.lOE-06 5.07E-07 5.23E-05 1.69E-06 0.

8.65E-07 1133+0 4.48E-06 5.49E-06 2.08E-06 1.04E-03 9.13E-06 0.

1.48E-06 1134 3.17E-07 5.84E-07 2.69E-07 1.37E-05 8.92E-07 0.

2.58E-07 1135+0 1.33E-06 2.36E-06 1.12E-06 2.14E-04 3.62E-06 0.

1.20E-06 XE131M

0.
0.
0.
0.
0.

3.30E-09 0.

XE133M

0.
0.
0.
0.
0.

4.36E-09 0.

XE133

0.
0.
0.
0.
0.

3.66E-09 0.

XE135M

0.
0.
0.
0.
0.

4.48E-09 0.

XE135

0.
0.
0.
0.
0.

9.09E-09 0.

XE137

0.
0.
0.
0.
0.

4.07E-08 0.

XE138+0

0.
0.
0.
0.
0.

5.17E-08 0.

CS134M+O 6.33E-08 8.92E-08 6.12E-08

0.

4.94E-08 8.35E-09 7.92E-08 CS134 l.76E-04 2.74E-04 6.07E-05

0.

8.93E-05 3.27E-05 1.04E-06 CS135 6.23E-05 4.13E-05 4.45E-06

0.

l.53E-05 5.22E-06 2.17E-07 CS136 l.76E-05 4.62E-05 3.14E-05

0.

2.58E-05 3.93E-06 l.13E-06 CS137+0 2.45E-04 2.23E-04 3.47E-05

0.

7.63E-05 2.81E-05 9.78E-07 CS138 l.71E-07 2.27E-07 l.50E-07

0.

1.68E-07 l.84E-08 7.29E-08 CS139+0 l.09E-07 l.15E-07 5.SOE-08

0.

9.08E-08 9.36E-09 7.23E-12 BA139 4.98E-10 2.66E-13 l.45E-ll

0.

2.33E-13 l.56E-06 l.56E-05 BA140+0 2.00E-05 l.75E-08 1.17E-06

0.

5.71E-09 4.71E-04 2.75E-05 BA141+0 5.29E-ll 2.95E-14 l.72E-12

0.

2.56E-14 7.89E-07 7.44E-08 BA142+0 l.35E-ll 9.73E-15 7.54E-13

0.

7.87E-15 4.44E-07 7.41E-10 LA140 1.74E-07 6.08E-08 2.04E-08

0.
0.

4.94E-05 6.lOE-05 LA141 2.28E-09 5.31E-10 l.15E-10

0.
0.

4.48E-06 4.37E-05 LA142 3.50E-10 l.llE-10 3.49E-ll

0.
0.

2.35E-06 2.05E-05 CE141 l.06E-05 5.28E-06 7.83E-07

0.

2.31E-06 l.47E-04 l.53E-05 CE143+0 9.89E-08 5.37E-08 7.77E-09

0.

2.26E-08 3.12E-05 3.44E-05 CE144+0 l.83E-03 5.72E-04 9.77E-05

0.

3.17E-04 3.23E-03 l.05E-04 PR143 4.99E-06 l.50E-06 2.47E-07

0.

8.llE-07 l.17E-04 2.63E-05 PR144 l.61E-ll 4.99E-12 8.lOE-13

0.

2.64E-12 4.23E-07 5.32E-08 ND147+0 2.92E-06 2.36E-06 l.84E-07

0.

l.30E-06 8.87E-05 2.22E-05 PM147 3.52E-04 2.52E-05 l.36E-05. 0.

4.45E-05 2.20E-04 5.70E-06 PM148M+O 3.31E-05 6.55E-06 6.55E-06

0.

9.74E-06 5.72E-04 3.58E-05 PM148 l.61E-06 1.94E-07 l.25E-07

0.

3.30E-07 1.24E-04 6.0lE-05 PM149 1.47E-07 1.56E-08 8.45E-09

0.

2.75E-08 2.40E-05 2.92E-05 PM151 3.57E-08 4.33E-09 2.82E-09

0.

7.35E-09 l.24E-05 2.50E-05 SM151 3.14E-04 4.75E-05 1.49E-05

0.

4.89E-05 1.48E-04 3.43E-06 SM153 7.24E-08 4.51E-08 4.35E-09

0.

1.37E-08 1.37E-05.1.87E-05 EU152 7.42E-04 1.37E-04 1.61E-04

0.

5.73E-04 9.00E-04 1.14E-05 EU154 2.74E-03 2.49E-04 2.27E-04

0.

l.09E-03 1.66E-03 2.98E-05 EU155 5.60E-04 4.05E-05 3.18E-05

0.

l.51E-04 2.79E-04 5.39E-05 EU156 7.89E-06 4.23E-06 8.75E-07

0.

2.72E-06 2.54E-04 4.24E-05 TB160 7.79E-05 0.

9.67E-06

0.

2.32E-05 5.34E-04 2.28E-05 H0166M 1.34E-03 2.81E-04 2.37E-04

0.

4.0lE-04 l.13E-03 l.63E-05 Wl81 2.66E-08 6.52E-09 8.99E-10

0.
0.

5.71E-06 2.61E-07 Wl85 8.31E-07 2.08E-07 2.91E-08

0.
0.

l.86E-04 1.llE-05 W187 4.41E-09 2.61E-09 l.17E-09

0.
0.

l.llE-05 2.46E-05 45

PALISADES NUCLEAR PLANT OFFSITE DOSE CALCULATION MANUAL Revision 9 TABLE 1.7 (contd)

CHILD INHALATION DOSE COMMITMENT FACTORS CMREM/50Y PER PC! INHALED IN FIRST YR)

ISOTOPE BONE LIVER TOTAL BODY THYROID KIDNEY LUNG GI*LLI PB210+D 8.03E-02 1.BSE-02 3.lBE-03

0.

6.31E-02 8.74E-02 3.75E-05 BI210+D

0.

5.llE-06 5.65E-07

0.

5.76E-05 3.70E-03 3.21E-05 P0210 1.70E-03 2.76E-03 4.09E-04

0.

8.85E-03 1.05E-Ol 4.32E-05 RN222+D 0.

0.

0.

0.

0.
4. 82E -06 0.

RA223+D 7.69E-04 8.89E-07 1.54E-04

0.

2.36E-05 8.48E-02 3.00E-04 RA224+D 8.44E-05 1.53E-07 1.69E-05

0.

4.06E-06 2.92E-02 3.34E-04 RA225+D 1.28E-03 1.14E-06 2.56E-04

0.

3.02E-05 9.74E-02 2.84E-04 RA226+D 2.34E-Ol 7.66E-06 1.92E-01

0.

2.03E-04 3.90E-01 3.02E-04 RA228+D 1.49E-01 3.94E-06 1.68E-01

0.

1.04E-04 5.37E-01 5.14E-05 AC225 1.81E-03 1.87E-03 1.21E-04

0.

1.99E-04 7.37E-02 2.67E-04 AC227+D 4.96E+OO 8.0SE-01 3.07E-01

0.

1.77E-01 8.04E-01 5.22E-05 TH227+D 9.24E-04 1.26E-05 2.67E-05

0.

6.67E-05 l.26E-01 3.49E-04 TH228+D 8.06E-01 1.04E-02 2.72E-02

0.

5.41E-02 3.34E+OO 3.59E-04 TH229 1.28E+Ol 1.76E-01 6.31E-Ol

0.

8.68E-01 1.04E+Ol 3.27E-04 TH230 3.30E+OO 1.73E-01 9.20E-02

0.

8.52E-Ol l.85E+OO 3.84E-05 TH232+D 3.68E+OO 1.47E-01 1.28E-01

0.

7.28E-01 1.77E+OO 3.27E-05 TH234 6.94E-06 3.07E-07 2.00E-07

0.

1.62E-06 6.31E-04 7.32E-05 PA231+D 8.62E+OO 2.86E-01 3.43E-01

0.

1.56E+OO 1.92E-01 4.57E-05 PA233 4.14E-06 6.48E-07 7.25E-07

0.

2.38E-06 9.77E-05 8.95E-06 U232+0 2.19E-01 0.

1.56E-02

0.

1.67E-02 7.42E-01 4.33E-05 U233+D 4.64E-02 0.

2.82E-03

0.

7.62E-03 1.77E-01 4.00E-05 U234 4.46E-02 0.

2.76E-03

0.

7.47E-03 1.74E-01 3.92E-05 U235+0 4.27E-02 0.

2.59E-03

0.

7.0lE-03 1.63E-01 4.98E-05 U236 4.27E-02 0.

2.65E-03

0.

7.16E-03 1.67E-01 3.67E-05 U237 1.57E-07 0.

4.17E-08

0.

4.53E-07 3.40E-05 1.29E-05 U238+D 4.09E-02 0..

2.42E-03

0.

6.55E-03 1.53E-01 3.51E-05 NP237+D 2.88E+OO 2.21E-01 1.19E-01

0.

7.41E-01 1.74E-01 5.06E-05 NP238 1.26E-06 2.56E-08 1.97E-08

0.

8.16E-08 3.39E-05 2.50E-05 NP239 1.26E-07 9.04E-09 6.35E-09

0.

2.63E-08 1.57E-05 1.73E-05 PU238 4.77E+OO 6.05E-01 1.21E-01

0.

4.47E-01 6.0BE-01 4.65E-05 PU239 5.24E+OO 6.44E-01 1.28E-01

0.

4.78E-01 5.72E-01 4.24E-05 PU240 5.23E+OO 6.43E-01 1.27E-01

0.

4.77E-01 5.71E-01 4.33E-05 PU241+0 1.46E-01 6.33E-03 2.93E-03

0.

1.lOE-02 5.06E-04 8.90E-07 PU242 4.85E+OO 6.20E-01 1.23E-01

0.

4.60E-01 5.50E-01 4.16E-05 PU244 5.67E+OO 7.lOE-01 1.41E-01

0.

5.27E-01 6.30E-01 6.20E-05 AM241 1.74E+OO 7.85E-01 1.24E-01

0.

7.63E-01 2.02E-01 4.73E-05 AM242M 1.79E+OO 7.65E-01 1.27E-01

0.

7.71E-01 8.14E-02 5.96E-05 AM243 1.72E+OO 7.53E-01 1.20E-01

0.

7.42E-01 1.92E-01 5.55E-05 CM242 6.33E-02 4.84E-02 4.20E-03

0.

1.34E-02 1.31E-01 5.06E-05 CM243 1.61E+OO 7.33E-01 9.95E-02

0.

3.74E-01 2.lOE-01 4.98E-05 CM244 1.33E+OO 6.48E-01 8:31E-02

0.

3.06E-01 2.02E-01 4.82E-05 CM245 2.14E+OO 8.16E-01 1.28E-01

0.

5.03E-01 1.95E-01 4.49E-05 CM246 2.13E+OO 8.lSE-01 1.28E-01

0.

5.03E-01 l.99E-Ol 4.41E-05 CM247+0

  • 2.07E+OO 8.02E-Ol 1.26E-01
0.

4.95E-Ol 1.95E-01 5.80E-05 CM248 1.72E+Ol 6.61E+OO 1.04E+OO

0.

4.08E+OO l.61E+OO 9.35E-04 CF252 3.92E+OO 0.

9.33E-02

0.
0.

6.62E-01 1.84E-04 46

PALISADES NUCLEAR PLANT OFFSITE DOSE CALCULATION MANUAL Revision 9 TABLE 1.7 (contd)

TEEN INHALATION DOSE COMMITMENT FACTORS CMREM/SOY PER PCI INHALED IN FIRST YR)

ISOTOPE BONE LIVER TOTAL BODY THYROID KIDNEY LUNG GI-LLI H3*

0.

l.59E-07 l.59E-07 l.59E-07 l.59E-07 l.59E-07 l.59E-07 BElO 2.78E-04 4.33E-05 7.09E-06

0.
0.

3.84E-04 l.77E-05 Cl4 3.25E-06 6.09E-07 6.09E-07 6.09E-07 6.09E-07 6.09E-07 6.09E-07 Nl3 8.65E-09 8.65E-09 8.65E-09 8.65E-09 8.65E-09 8.65E-09 8.65E-09 Fl8 6.52E-07

0.

7.lOE-08

0.
0.
0.

3.89E-08 NA22 l.76E-05 l.76E-05 l.76E-05 l.76E-05 l.76E-05 l.76E-05 l.76E-05 NA24 l.72E-06 l.72E-06 l.72E-06 l.72E-06 l.72E-06 l.72E-06 l.72E-06 P32 2.36E-04 l.37E-05 8.95E-06

0.
0.
0.

l.16E-05 AR39

0.
0.
0.
0.
0.

4.00E-09 0.

AR41

0.
0.
0.
0.
0.

l.44E-08 0.

CA41 4.05E-05

0.

4.38E-06

0.
0.

l.OlE-01 3.03E-07 SC46 7.24E-05 l.41E-04 4.18E-05

0.

l.35E-04 0.

2.98E-05 CRSl

0.
0.

l.69E-08 9.37E-09 3.84E-09 2.62E-06 3.75E-07 MN54

0.

6.39E-06 l.05E-06

0.

l.59E-06 2.48E-04 8.35E-06 MN56

0.

2.12E-10 3.15E-ll

0.

2.24F-10 l.90E-06 7.18E-06 FESS 4.18E-06 2.98E-06 6.93E-07

0.
0.

l.55E-05 7.99E-07 FE59 l.99E-06 4.62E-06 l.79E-06

0.
0.

l.91E-04 2.23E-05 COS?

0.

l.18E-07 l.15E-07

0.
0.

7.33E-OS 3.93E-06 C058

0.

2.59E-07 3.47E-07

0.
0.

l.68E-04 l.19E-05 C060

0.

l.89E-06 2.48E-06

0.
0.

l.09E-03 3.24E-05 NI59 5.44E-06 2.02E-06 9.24E-07

  • 0.
0.

l.41E-05 6.48E-07 NI63 7.25E-05 5.43E-06 2.47E-06

0.
0.

3.84E-05 l.77E-06 NI65 2.73E-10 3.66E-ll l.59E-ll

0.
0.

l.l?E-06 4.S9E-06 CU64

0.

2.54E-10 l.06E-10

0.

8.0lE-10 l.39E-06 7.68E-06 ZN65 4.82E-06 l.67E-05 7.80E-06

0.

l.OBE-05 l.55E-04 5.83E-06 ZN69M+D l.44E-09 3.39E-09 3.llE-10

0.

2.06E-09 3.92E-06 2.14E-OS ZN69 6.04E-12 l.15E-ll 8.0?E-13

0.

7.53E-12 l.98E-07 3.56E-08 SE79

0.

5.43E-07 8.71E-08

0.

8.13E-07 7.71E-05 3.53E-06 BR82

0.
0.

2.28E-06

0.
0.
0.
0.

BR83+0

0.
0.

4.30E-08

0.
0.
0.
0.

BR84

0.
0.

S.41E-08

0.
0.
0.
0.

BR85

0.
0.

2.29E-09

0.
0.
0.
0.

KR83M

0.
0.
0.
0.
0.

9.97E-10 0.

KR8SM

0.
0.
0.
0.
0.

S.46E-09 0.

KR85

0.
0.
0.
0.
0.
4. 63E-09
0.

KR87

0.
0.
0.
0.
0.

2.82E-08 0.

KR88+0

0.
0.
0.
0.
0.

5.BlE-08 0.

KR89

0.
0.
0.
0.
0.
3. 85E-08 0.

RB86

0.

2.38E-OS l.OSE-05

0.
0.
0.

2.21E-06 RB87

0.

l.40E-05 4.58E-06

0.
0.
0.

3.0SE-07 RB88

0.

6.82E-08 3.40E-08

0.
0.
0.

3.6SE-15 RB89+0

0.

4.40E-08 2.91E-08

0.
0.
0.

4.22E-17 SR89+0 5.43E-05 0.

l.56E-06

0.
0.

3.02E-04 4.64E-05 SR90+0 l.35E-02 0.

8.35E-04

0.
0.

2.06E-03 9.56E-05 SR9l+D l.lOE-08 0.

4.39E-10

0.
0.

7.59E-06 3.24E-05 SR92+0 l.19E-09 0.

  • 5.0SE-11
0.
0.

3.43E-06 l.49E-05

  • Includes a 50% increase to account for percutaneous transpiration.

47

PALISADES NUCLEAR PLANT OFFSITE DOSE CALCULATION MANUAL Revision 9 TABLE 1.7 (contd)

TEEN INHALATION DOSE COMMITMENT FACTORS CMREM/50Y PER PCI INHALED IN FIRST YR)

ISOTOPE Y90 Y91M+D Y91 Y92 Y93 ZR93+D ZR95+D ZR97+D N893M N895 N897 M093 M099+D TC99M TC99 TClOl RU103+0 RU105+0 RU106+D RH105 PD107 PD109 AGllOM+D AGlll CD113M CD115M 5Nl23 5Nl25+D 5Nl26+D 58124 58125+0 58126 58127 TE125M TE127M+D TE127 TE129M+D TE129 TE131M+D TE13l+D TE132+D TE133M+D TE134+D 1129 1130 1131 +D BONE LIVER TOTAL BODY THYROID KIDNEY LUNG GI*LLI 3.73E-07 0.

l.OOE-08

0.
0.

3.66E-05 6.99E-05 4.63E-11

0.

1.77E-12

0.
0.

4.00E-07 3.77E-09 8.26E-05 0.

2.21E-06

0.
0.

3.67E-04 5.llE-05 l.84E-09 0.

5.36E-ll

0.
0.

3.35E-06 2.06E-05 l.69E-08 0.

4.65E-10

0.
0.

l.04E-05 7.24E-05 6.83E-05 3.38E-05 l.84E-05

0.

l.16E-04 3.67E-04 l.60E-05 l.82E-05 5.73E-06 3.94E-06

0.

8.42E-06 3.36E-04 l.86E-05 1.72E-08 3.40E-09 1.57E-09

0.

5.15E-09 l.62E-05 7.88E-05 4.14E-05 l.36E-05 3.41E-06

0.

l.59E-05 5.36E-05 2.52E-06 2.32E-06 l.29E-06 7.08E-07

0.

l.25E-06 9.39E-05 l.21E-05 3.92E-ll 9.72E-12 3.55E-12

0.

l.14E-ll 4.91E-07 2.71E-07

0.

l.66E-06 4.52E-08

0.

5.06E-07 8.81E-05 3.99E-06

0.

2.llE-08 4.03E-09

0.

5.14E-08 l.92E-05 3.36E-05 l.73E-13 4.83E-13 6.24E-12

0.

7.20E-12 l.44E-07 7.66E-07 4.48E-08 6.58E-08 l.79E-08

0.

8.35E-07 l.74E-04 7.99E-06 7.40E-15 l.05E-14 l.03E-13

0.

l.90E-13 8.34E-08 l.09E-16 2.63E-07 0.

l.12E-07

0.

9.29E-07 9.79E-05 l.36E-05 l.40E-10 0.

5.42E-ll

0.

l.76E-10 2.27E-06 l.13E-05 l.23E-05 0.

l.55E-06

0.

2.38E-05 2.0lE-03 l.20E-04 l.32E-09 9.48E-10 6.24E-10

0.

4.04E-09 4.09E-06 l.23E-05

0.

l.17E-07 8.39E-09

0.

9.39E-07 l.63E-05 7.49E-07

0.

6.56E-10 l.66E-10

0.

3.36E-09 3.19E-06 l.96E-05 l.73E-06 l.64E-06 9.99E-07

0.

3.13E-06 8.44E-04 3.41E-05 6.07E-08 2.52E-08 l.26E-08

0.

8.17E-08 4.00E-05 3.00E-05

0.

2.17E-04 7.lOE-06

0.

2.43E-04 3.59E-04 l.68E-05

0.

3.48E-05 l.14E-06

0.

2.82E-05 3.03E-04 5.lOE-05 4.31E-05 9.44E-07 l.40E-06 7.55E-07 0.

4.96E-04 4.16E-05 l.66E-06 4.42E-08 9.99E-08 3.45E-08 0.

l.26E-04 7.29E-05 2.18E-04 5.39E-06 8.24E-06 1.42E-06 0.

l.72E-03 l.68E-05 5.38E-06 9.92E-08 2.lOE-06 l.22E-08 0.

4.81E-04 4.98E-05 9.23E-06 l.OlE-07 2.15E-06 8.80E-09 0.

3.42E-04 l.24E-05 6.19E-07 l.27E-08 2.23E-07 3.50E-09 0.

l.55E-04 6.0lE-05 4.64E-08 9.92E-10 l.75E-08 5.21E-10 0.

3.31E-05 3.94E-05 6.lOE-07 2.80E-07 8.34E-08 l.75E-07 0.

6.70E-05 9.38E-06 2.25E-06 l.02E-06 2.73E-07 5.48E-07 8.17E-06 2.07E-04 l.99E-05 2.51E-10 l.14E-10 5.52E-ll l.77E-10 9.lOE-10 l.40E-06 l.OlE-05 l.74E-06 8.23E-07 2.81E-07 5.72E-07 6.49E-06 2.47E-04 5.06E-05 8.87E-12 4.22E-12 2.20E-12 6.48E-12 3.32E-ll 4.12E-07 2.02E-07 l.23E-08 7.51E-09 5.03E-09 9.06E-09 5.49E-08 2.97E-05 7.76E-05 l.97E-12 l.04E-12 6.30E-13 l.55E-12 7.72E-12 2.92E-07 l.89E-09 4.50E-08 3.63E-08 2.74E-08 3.07E-08 2.44E-07 5.61E-05 5.79E-05 l.OlE-11 7.33E-12 5.71E-12 8.18E-12 5.07E-11 8.71E-07 1.23E-07 5.31E-12 4.35E-12 3.64E-12 4.46E-12 2.91E-11 6.75E-07 l.37E-09 3.53E-06 2.94E-06 4.90E-06 3.66E-03 5.26E~06 0.

2.29E-07 7.80E-07 2.24E-06 8.96E-07 l.86E-04 3.44E-06 0.

l.14E-06 4.43E-06 6.14E-06 3.30E-06 l.83E-03 l.05E-05 0.

8.llE-07 48

PALISADES NUCLEAR PLANT OFFSITE DOSE CALCULATION MANUAL Revision 9 TABLE 1.7 (contd)

TEEN INHALATION DOSE COMMITMENT FACTORS CMREM/50Y PER PCI INHALED IN FIRST YR)

ISOTOPE BONE LIVER TOTAL BODY THYROID KIDNEY LUNG GI*LLI 1132 l.99E-07 5.47E-07 l.97E-07 l.89E-05 8.65E-07 0.

l.59E-07 1133+0 l.52E-06 2.56E-06 7.78E-07 3.65E-04 4.49E-06 0.

l.29E-06 1134 l.llE-07 2.90E-07 l.05E-07 4.94E-06 4.58E-07 0.

2.55E-09 1135+0 4.62E-07 l.lBE-06 4.36E-07 7.76E-05 l.86E-06 0.

8.69E-07 XE131M

0.
0.
0.
0.
0.

2.70E-09 0.

XE133M

0.
0.
0.
0.
0.

3.59E-09 0.

XE133

0.
0.
0.
0.
0.

2.99E-09 0.

XE135M

0.
0.
0.
0.
0.

3.BBE-09 0.

XE135

0.
0.
0.
0.
0.

7.55E-09 0.

XE137

0.
0.
0.
0.
0.

3.33E-08 0.

XE138+0

0.
0.
0.
0.
0.

4.38E-08 0.

CS134M+O.

2.20E-08 4.35E-08 2.35E-08

0.

2.54E-08 4.56E-09 2.02E-08 CS134 6.28E-05 l.41E-04 6.86E-05

0.

4.69E-05 l.83E-05 l.22E-06 CS135 2.0BE-05 l.82E-05 4.47E-06

0.

7.30E-06 2.70E-06 2.23E-07 CS136 6.44E-06 2.42E-05 l.71E-05

0.

l.38E-05 2.22E-06 l.36E-06 CS137+0 8.38E-05 l.06E-04 3.89E-05

0.

3.BOE-05 l.51E-05 l.06E-06 CS138 5.82E-08 l.07E-07 5.58E-08

0.

8.28E-08 9.84E-09 3.38E-ll CS139+0 3.65E-08 5.12E-08 l.97E-08

0.

4.34E-08 4.86E-09 l.66E-23 BA139 l.67E-10 l.18E-13 4.87E-12

0.

l.llE-13 8.08E-07 8.06E-07 BA140+D 6.84E-06 8.38E-09 4.40E-07

0.

2.85E-09 2.54E-04 2.86E-05 BA14l+D l.78E-ll l.32E-14 5.93E-13

0.

l.23E-14 4.llE-07 9.33E-14 BA142+D 4.62E-12 4.63E-15 2.84E-13

0.

3.92E-15 2.39E-07 5.99E-20 LA140 5.99E-08 2.95E-08 7.82E-09

0.
0.

2.68E-05 6.09E-05 LA141 7.63E-10 2.35E-10 3.87E-ll

0.
0.

2.31E-06 l.54E-05 LA142 l.20E-10 5.31E-ll l.32E-ll

0.
0.

l.27E-06 l.50E-06 CE141 3.55E-06 2.37E-06 2.71E-07

0.

l.llE-06 7.67E-05 l.58E-05 CE143+D 3.32E-08 2.42E-08 2.70E-09

0.

l.OBE-08 l.63E-05 3.19E-05 CE144+D 6.llE-04 2.53E-04 3.28E-05

0.

l.51E-04 l.67E-03 1.08E-04 PR143 l.67E-06 6.64E-07 8.28E-08

0.

3.86E-07 6.04E-05 2.67E-05 PR144 5.37E-12 2.20E-12 2.72E-13

0.

l.26E-12 2.19E-07 2.94E-14 ND147+0 9.83E-07 l.07E-06 6.41E-08

0.

6.28E-07 4.65E-05 2.28E-05 PM147 l.15E-04 1.lOE-05 4.50E-06

0.

2.lOE-05 l.14E-04 5.87E-06 PM148M+D l.32E-05 3.35E-06 2.62E-06

0.

5.07E-06 3.20E-04 4.lOE-05 PM148 5.44E-07 8.88E-08 4.48E-08

0.

l.60E-07 6.52E-05 6.14E-05 PM149 4.91E-08 6.89E-09 2.84E-09

0.

l.31E-08 l.24E-05 2.79E-05 PM151 1.20E-08 l.99E-09 1.0lE-09

0.

3.57E-09 6.56E-06 2.27E-05 SM151 l.07E-04 2.lOE-05 4.86E-06

0.

2.27E-05 7.68E-05 3.53E-06 SM153 2.43E-08 2.0lE-08 1.47E-09

0.

6.56E-09 7.llE-06 1.77E-05 EU152 2.96E-04 7.19E-05 6.30E-05

0.

3.34E-04 5.0lE-04 1.35E-05 EU154 9.43E-04 1.23E-04 8.60E-05

0.

5.44E-04 9.12E-04 3.34E-05 EU155 2.00E-04

  • 1.96E-05 l.21E-05
0.

7.65E-05 l.51E-03 5.97E-05 EU156 2.70E-06 2.03E-06 3.30E-07

0.

1.36E-06 l.37E-04 4.56E-05 TB160 3.04E-05 0.

3.79E-06

0.

l.20E-05 2.97E-04 2.60E-05 H0166M 4.40E-04 1.36E-04 9.87E-05

0.

2.00E-04 6.24E-04 l.68E-05 Wl81.

8.90E-09 2.BBE-09 3.0lE-10

0.
0.

2.95E-06 2.69E-07 Wl85 2.78E-07 9.17E-08 9.73E-09

0.
0.

9.60E-05 l.14E-05 Wl87 l.50E-09 l.22E-09 4.29E-10

0.
0.

5.92E-06 2.21E-05 49

PALISADES NUCLEAR PLANT OFFSITE DOSE CALCULATION MANUAL Revision 9 TABLE 1.7 (contd)

TEEN INHALATION DOSE COMMITMENT FACTORS CMREM/50Y PER PCI INHALED IN FIRST YR)

ISOTOPE BONE LIVER TOTAL BODY THYROID KIDNEY LUNG GI*LLI PB210+0 3.09E-02 8.28E-03 l.07E-03

0.

2.95E-02 4.52E-02 3.87E-05 BI210+0

0.

2.26E-06 l.89E-07

0.

2.74E-05 l.91E-03 3.19E-05 P0210 5.68E-04 l.22E-03 l.37E-04

0.

4.21E-03 5.41E-02 4.45E-05 RN222+0

0.
0.

0.

0.
0.
3. 94E -06 0.

RA223+0 2.57E-04 3.93E-07 5.14E-05

0.

l.12E-05 4.39E-02 3.04E-04 RA224+0 2.83E-05 6.77E-08 5.65E-06

0.

l.93E-06 l.51E-02 3.29E-04 RA225+0 4.28E-04 5.04E-07 8.56E-05

0.

l.44E-05 5.04E-02 2.89E-04 RA226+0 l.33E-Ol 3.38E~06 9.87E-02

0.

9.67E-05 2.02E-Ol 3.llE-04 RA228+0 5.34E-02 l.74E-06 5.88E-02

0.

4.97E-05 2.78E-Ol 5.30E-05 AC225 6.04E-04 8.25E-04 4.06E-05

0.

9.47E-05 3.SlE-02 2.70E-04 AC227+0 2.49E+OO 3.69E-Ol l.48E-Ol

0.

l.07E-Ol 4.16E-Ol 5.38E-05 TH227+0 3.09E-04 5.56E-06 8.93E-06

0.

3.18E-05 6.50E-02 3.57E-04 TH228+0 2.60E-Ol 4.37E-03 8.78E-03

0.

2.45E-02 l.69E+OO 3.70E-04 TH229 9.06E+OO l.36E-Ol 4.45E-Ol

0.

6.67E-Ol 5.05E+OO 3.36E-04 TH230 2.34E+OO l.34E-Ol 6.49E-02

0.

6.55E-Ol 8.98E-Ol 3.95E-05 TH232+0 2.61E+OO l.14E-Ol 9.21E-02

0.

5.60E-Ol 8.60E-Ol 3.36E-05 TH234 2.32E-06 l.35E-07 6.71E-08

0.

7.73E-07 3.26E-04 7.49E-05 PA231+0 5.32E+OO 2.00E-01 2.0?E-01

0.

l.12E+OO 9.91E-02 4.71E-05 PA233 l.68E-06 3.24E-07 2.89E-07

0.

l.22E-06 5.39E-05 l.OOE-05 U232+0 7.31E-02 0.

5.23E-03

0.

7.94E-03 3.84E-Ol 4.46E-05./

U233+0 l.55E-02 0.

9.42E-04

0.

3.63E-03 9.lSE-02 4.12E-05 U234 l.48E-02 0.

9.23E-04

0.

3.55E-03 8.99E-02 4.04E-05 U235+0 l.42E-02 0.

8.67E-04

0.

3.34E-03 8.44E-02 5.13E-05 U236 l.42E-02 0.

8.86E-04

0.

3.41E-03 8.62E-02 3.79E-05 U237 5.25E-08 0.

l.40E-08

0.

2.16E-07 l.76E-05 l.29E-05 U238+0 l.36E-02 0.

8.lOE-04

0.

3.12E-03 7.89E-02 3.62E-05 NP237+0 l.77E+OO l.54E-Ol 7.21E-02

0.

5.35E-Ol 8.99E-02 5.22E-05 NP238 4.23E-07 l.13E-08 6.59E-09

0.

3.88E-08 l.75E-05 2.38E-05 NP239 4.23E-08 3.99E-09 2.21E-09

0.

l.25E-08 8.llE-06 l.65E-05 PU238 2.86E+OO 4.06E-Ol 7.22E-02

0.

3.lOE-01 3.12E-Ol 4.79E-05 PU239 3.31E+OO 4.50E-Ol 8.05E-02

0.

3.44E-Ol 2.93E-Ol 4.37E-05 PU240 3.31E+OO 4.49E-Ol 8.04E-02

0.

3.43E-Ol 2.93E-Ol 4.46E-05 PU241+0 6.97E-02 3.57E-03 l.40E-03

0.

6.47E-03 2.60E-04 9.17E-07 PU242 3.07E+OO 4.33E-Ol 7.75E-02

0.

3.31E-Ol 2.82E-Ol 4.29E-05 PU244 3.59E+OO 4.96E-Ol 8.88E-02

0.

3.79E-Ol 3.23E-Ol 6.39E-05 AM241 l.06E+OO 4.07E-Ol 7.lOE-02

0.

5.32E-Ol l.05E-Ol 4.88E-05 AM242M l.07E+OO 3.93E-Ol 7.15E-02

0.

5.30E-Ol 4.21E-02 6.14E-05 AM243 l.06E+OO 3.92E-Ol 6.95E-02

0.

5.21E-Ol 9.91E-02 5.72E-05 CM242 2.12E-02 2.14E-02 l.41E-03

0.

6.40E-03 6.76E-02 5.21E-05 CM243 8.45E-Ol 3.50E-Ol 5.00E-02

0.

2.34E-Ol l.09E-Ol 5.13E-05 CM244 6.46E-Ol 3.03E-Ol 3.88E-02

0.

l.81E-Ol l.05E-Ol 4.96E-05 CM245 l.32E+OO 4.llE-01 7.53E-02

0.

3.52E-Ol l.OlE-01 4.63E-05 CM246 l.31E+OO 4.llE-01 7.52E-02

0.

3.51E-Ol l.03E-Ol 4.54E-05 CM247+0 l.28E+OO 4.04E-Ol 7.41E-02

0.

3.46E-Ol l.QlE-01 5.97E-05 CM248 l.06E+Ol 3.33E+OO 6.llE-01

0.

2.85E+OO 8.32E-Ol 9.63E-04 CF252 l.29E+OO 0..

3.07E-02

0.
0.

3.43E-Ol l.89E-04

  • 50

I PALISADES NUCLEAR PLANT OFFSITE DOSE CALCULATION MANUAL Revision 9 TABLE 1.7 (contd)

ADULT. INHALATION DOSE COMMITMENT FACTORS CMREM/50Y PER PCI INHALED IN FIRST YR)

ISOTOPE BONE LIVER TOTAL BODY THYROID KIDNEY LUNG GI-LLI H3*

0.

l.5SE-07 l.SSE-07 l.5SE-07 l.5SE-07 l.5SE-07 l.5SE-07 BElO l.9SE-04 3.06E-05 4.96E-06

0.
0.

2.22E-04 l.67E-05 Cl4 2.27E-06 4.26E-07 4.26E-07 4.26E-07 4.26E-07 4.26E-07 4.26E-07 Nl3 6.27E-09 6.27E-09 6.27E-09 6.27E-09 6.27E-09 6.27E-09 6.27E-09 FlS 4.?lE-07 0.

5.19E-OS

0.
0.
0.

9.24E-09 NA22 l.30E-05 l.30E-05 l.30E-05 l.30E-05 l.30E-05 l.30E-05 l.30E-05 NA24 l.2SE-06 l.2SE-06 l.2SE-06 l.2SE-06 l.2SE-06 l.2SE-06 l.2SE-06 P32 l.65E-04 9.64E-06 6.26E-06

0.
0.
0.

l.OSE-05 AR39

0.
0.
0.
0.
0.

2.0SE-09

0.

AR41

0.
0.
0.
0.
0.

S.06E-09 0.

CA41 3.S3E-05 0.

4.13E-06

0.
0.

3.S3E-06 2.S6E-07 SC46 5.51E-05 l.O?E-04 3.llE-05

0.

9.99E-05 0.

3.23E-05 CR51

0.
0.

1.25E-OS 7.44E-09 2.S5E-09 1.SOE-06 4.15E-07 MN54

0.

4.95E-06 7.S?E-07

0.

1.23E-06 1.75E-04 9.67E-06 MN56

0.

1.55E-10 2.29E-11

0.

1.63E-10 1.lSE-06 2.53E-06 FE55 3.0?E-06 2.12E-06 4.93E-07

0.
0.

9.0lE-06 7.54E-07 FE59 1.47E-06 3.47E-06 l.32E-06

0.
0.

1.27E-04 2.35E-05 C057 O:

S.65E-OS S.39E-OS

0.
0.

4.62E-05 3.93E-06 COSS 0,

1.9SE-07 2.59E-07

0.
0.

l.16E-04 1.33E-05 C060

0.

l.44E-06 l.S5E-06

0.
0.

7.46E-04 3.56E-05 NI59 4.06E-06 1.46E-06 6.77E-07

0.
0.

S.20E-06 6.llE-07 NI63 5.40E-05 3.93E-06 1.SlE-06

0.
0.

2.23E-05 1.67E-06 NI65 l.92E-10 2.62E-11 l.14E-ll

0.
0.

7.00E-07 l.54E-06 CU64

0.

l.S3E-10 7.69E-ll

0.

5.?SE-10 S.4SE-07 6.12E-06 ZN65 4.05E-06 l.29E-05 5.S2E-06

0.

S.62E-06 l.OSE-04 6.6SE-06 ZN69M+D l.02E-09 2.45E-09 2.24E-10

0.

l.48E-09 2.38E-06 l.?lE-05 ZN69 4.23E-12 S.14E-12 5.65E-13

0.

5.27E-12 l.15E-07 2.04E-09 SE79

0.

3.S3E-07 6.09E-OS

0.

5.69E-07 4.47E-05 3.33E-06 BRS2

0.
0.

1.69E-06

0.
0.
0.

l.30E-06 BRS3+0

0.
0.

3.0lE-08

0.
0.
0.

2.90E-OS BRS4

0.
0.

3.91E-OS

0.
0.
0.

2.05E-13 BRS5

0.
0.

l.60E-09

0.
0.
0.
0.

KRS3M

0.
0.
0.
0.
0.

5.19E-10 0.

KRS5M

0.
0.
0.
0.
0.

2.91E-09 0.

KRS5

0.
0.
0.
0.
0.

2.41E-09 0.

KRS?

0.
0.
0.
0.
0.

l.53E-OS

0.

KRSS+O

0.
0.
0.
0.
0.

3.13E-OS 0.

KRS9

0.
0.
0.
0.
0.

2.13E-OS 0.

RBS6

0.

l.69E-05 7.37E-06. 0.

0.
0.

2.0BE-06 RBS?

0.

9.S6E-06 3.21E-06

0.
0.
0.

2.SSE-07 RBSS

0.

4.S4E-OS 2.41E-OS

0.
0.
0.

4.lSE-19 RBS9+0

0.

3.20E-OS 2.12E-OS

0.
0.
0.

l.16E-21 SRS9+0 3.SOE-05 0.

l.09E-06

0.
0.

l.75E-04 4.37E-05 SR90+0 l.24E-02 0.

7.62E-04. 0.

0.

l.20E-03 9.02E-05 SR91+0 7.74E-09 0.

3.13E-10

0.
0.

4.56E-06 2.39E-05 SR92+D S.43E-10 0.

3.64E-ll

0.
0.

2.06E-06 5.3SE-06

  • Includes a 50% increase to account for percutaneous transpiration.

51

PALISADES NUCLEAR PLANT OFFSITE DOSE CALCULATION MANUAL Revision 9 TABLE 1.7 (contd)

ADULT INHALATION DOSE COMMITMENT FACTORS CMREM/50Y PER PCI INHALED IN FIRST YR)

ISOTOPE BONE LIVER TOTAL BODY THYROID KIDNEY LUNG GI-LLI Y90 2.61E-07

0.

7.0lE-09

0.
0.

2.12E-05 6.32E-05 Y91M+D 3.26E-11

0.

l.27E-12

0.
0.

2.40E-07 l.66E~10 Y91 5.78E-05 0.

l.55E-06

0.
0.

2.13E-04 4.BlE-05 Y92 1.29E-09 0.

3.77E-ll

0.
0.

1.96E-06 9.19E-06 Y93 l.lBE-08 0.

3.26E-10

0.
0.

6.06E-06 5.27E-05 ZR93+D 5.22E-05 2.92E-06 l.37E-06

0.

l.llE-05 2.13E-05 l.51E-06 ZR95+0 l.34E-05 4.30E-06 2.91E-06

0.

6.77E-06 2.21E-04 l.BBE-05 ZR97+D l.21E-08 2.45E-09 l.13E-09

0.

3.71E-09 9.84E-06 6.54E-05 NB93M 3.lOE-05 l.OlE-05 2.49E-06

0.

l.16E-05 3.llE-05 2.38E-06 NB95 l.76E-06 9.77E-07 5.26E-07

0.

9.67E-07 6.31E-05 l.30E-05 NB97 2.78E-ll 7.03E-12 2.56E-12

0.

8.lBE-12 3.00E-07 3.02E-08 M093

0.

l.17E-06 3.17E-08

0.

3.55E-07 5.llE-05 3.79E-06 M099+0

0.

1.51E-08 2.87E-09

0.

3.64E-08 l.14E-05 3.lOE-05 TC99M l.29E-13 3.64E-13 4.63E-12

0.

5.52E-12 9.55E-08 5.20E-07 TC99 3.13E-08 4.64E-08 l.25E-08

0.

5.85E-07 l.OlE-04 7.54E-06 TClOl 5.22E-15 7.52E-15 7.38E-14

0.

l.35E-13 4.99E-08 l.36E-21 RU103+D l.91E-07

0.

8.23E-08

0.

7.29E-07 6.31E-05 l.38E-05 RU105+D 9.88E-ll 0.

3.89E-ll

0.

l.27E-10 l.37E-06 6.02E-06 RU106+D 8.64E-06 0.

l.09E-06

0.

l.67E-05 l.17E-03 l.14E-04 RH105 9.24E-10 6.73E-10 4.43E-10

0.

2.86E-09 2.41E-06 l.09E-05 PD107

0.

8.27E-08 5.87E-09

0.

6.57E-07 9.47E-06 7.06E-07 PD109

0.

4.63E-10 l.16E-10

0.

2.35E-09 l.85E-06 l.52E-05 AGllOM+D l.35E-06 l.25E-06 7.43E-07

0.

2.46E-06 5.79E-04 3.78E-05 AGlll 4.25E-08 l.78E-08 8.87E-09

0.

5.74E-08 2.33E-05 2.79E-05 CD113M

0.

l.54E-04 4.97E-06

0.

l.71E-04 2.0BE-04 l.59E-05 CD115M

0.

2.46E-05 7.95E-07

0.

1.98E-05 l.76E-04 4.BOE-05 SN123 3.02E-05 6.67E-07 9.82E-07 5.67E-07 0.

2.88E-04 3.92E-05 SN125+D l.16E-06 3.12E-08 7.03E-08 2.59E-08 0.

7.37E-05 6.BlE-05 SN126+D l.58E-04 4.lBE-06 6.00E-06 l.23E-06 0.

l.17E-03 l.59E-05 SB124 3.90E-06 7.36E-08 l.55E-06 9.44E-09 0.

3.lOE-04 5.0BE-05 SB125+D 6.67E-06 7.44E-08 1:58E-06 6.75E-09 0.

2.18E-04 l.26E-05 SB126 4.50E-07 9.13E-09 l.62E-07 2.75E-09 0.

9.57E-05 6.0lE-05 SB127 3.30E-08 7.22E-10 l.27E-08 3.97E-10 0.

2.05E-05 3.77E-05 TE125M 4.27E-07 l.98E-07 5.84E-08 l.31E-07 l.55E-06 3.92E-05 8.83E-06 TE127M+D l.58E-06 7.21E-07 l.96E-07 4.llE-07 5.72E-06 l.20E-04 l.87E-05 TE127 l.75E-10 8.03E-11 3.87E-ll l.32E-10 6.37E-10 8.14E-07 7.17E-06 TE129M+D l.22E-06 5.84E-07 l.98E-07 4.30E-07 4.57E-06 1.45E-04 4.79E-05 TE129 6.22E-12 2.99E-12 l.55E-12 4.87E-12 2.34E-ll 2.42E-07 l.96E-08 TE131M+D 8.74E-09 5.45E-09 3.63E-09 6.BBE-09 3.86E-08 l.82E-05 6.95E-05 TE13l+D l.39E-12 7.44E-13 4.49E-13 l.17E-12 5.46E-12 l.74E-07 2.30E-09 TE132+D 3.25E-08 2.69E-08 2.02E-08 2.37E-08 l.82E-07 3.60E-05 6.37E-05 TE133M+D 7.24E-12 5.40E-12 4.17E-12 6.27E-12 3.74E-11 5.51E-07 5.49E-08 TE134+D 3.84E-12 3.22E-12 l.57E-12 3.44E-12 2.lBE-11 4.343-07 2.97E-ll 1129 2.48E-06 2.llE-06 6.91E-06 5.54E-03 4.53E-06 0.

2.22E-07 1130 5.72E-07 l.68E-06 6.60E-07 l.42E-04 2.61E-06 0.

9.61E-07 1131+0 3.lSE-06 4.47E-06 2.56E-06 l.49E-03 7.66E-06 0.

7.85E-07 52

PALISADES NUCLEAR PLANT OFFSITE DOSE CALCULATION MANUAL Revision 9 TABLE 1.7 (contd)

ADULT INHALATION DOSE COMMITMENT FACTORS CMREM/50Y PER PCI INHALED IN FIRST YR)

ISOTOPE BONE LIVER TOTAL BODY THYROID KIDNEY LUNG GI-LLI 1132 l.45E-07 4.07E-07 l.45E-07 l.43E-05 6.48E-07 0.

5.08E-08 1133+0 l.08E-06 l.85E-06 5.65E-07 2.69E-04 3.23E-06 0.

l.llE-06 1134 8.05E-08 2.16E-07 7.69E-08 3.73E-06 3.44E-07 0.

l.26E-10 1135+0 3.35E-07 8.73E-07 3.21E-07 5.60E-05 l.39E-06 0.

6.56E-07 XE131M

0.
0.
0.
0.
0.

l.40E-09 0.

XE133M

0.
0.
0.
0.
0.

l.89E-09 0.

XE133

0.
0.
0.
0.
0.

l.57E-09 0.

XE135M

0.
0.
0.
0.
0.

2.22E-09 0.

XE135

0.
0.
0.
0.
0.

4.05E-09 0.

XE137

0.
0.
0.
0.
0.

l.74E-08 0.

XE138+0

0.
0.
0.
0.
0.

2.44E-08 0.

CS134M+O l.59E-08 3.20E-08 l.72E-08

0.

1.83E-08 2.93E-09 7.92E-09 CS134 4.66E-05 l.06E-04 9.lOE-05

0.

3.59E-05 l.22E-05 l.30E-06 CS135 l.46E-05 l.29E-05 5.99E-06

0.

5.llE-06 l.57E-06 2.llE-07 CS136 4.88E-06 l.83E-05 l.38E-05

0.

l.07E-05 l.50E-06 l.46E-06 CS137+0 5.98E-05 7.76E-05 5.35E-05

0.

2.78E-05 9.40E-06 l.05E~06 CS138 4.14E-08 7.76E-08 4.05E-08

0.

6.00E-08 6.07E-09 2.33E-13 CS139+0 2.56E-08 3.63E-08 l.39E-08

0.

3.05E-08 2.84E-09 5.49E-31 BA139 l.17E-10 8.32E-14 3.42E-12

0.

7.78E-14 4.?0E-07 1.12E-07 BA140+0 4.88E-06 6.13E-09 3.21E-07

0.

2.09E-09 l.59E-04 2.73E-05 BA141+0 l.25E-ll 9.41E-15 4.20E-13

0.

8.75E-15 2.42E-07 l.45E-17 BA142+0 3.29E-12 3.38E-15 2.0?E-13

0.

2.86E-15 l.49E-07 l.96E-26 LA140 4.30E-08 2.17E-08 5.73E-09

0.
0.

l.70E-05 5.73E-05 LA141 5.34E-10 l.66E-10 2.71E-11

0.
0.

l.35E-06 7.31E-06 LA142 8.54E-ll 3.88E-ll 9.65E-12

0.
0.

7.91E-07 2.64E-07 CE141 2.49E-06 l.69E-06 l.91E-07

0.

7.83E-07 4.52E-05 l.50E-05 CE143+0 2.33E-08 l.72E-08 1.91E-09

0.

7.60E-09 9.97E-06 2.83E-05 CE144+0 4.29E-04 1.79E-04 2.30E-05

0.

1.06E-04 9.72E-04 l.02E-04 PR143 l.l?E-06 4.69E-07 5.80E-08

0.

2.?0E-07 3.51E-05 2.50E-05 PR144 3.76E-12 l.56E-12 l.91E-13

0.

8.81E-13 l.27E-07 2.69E-18 N0147+0 6.59E-07 7.62E-07 4.56E-08

0.

4.45E-07 2.76E-05 2.16E-05 PM147 8.37E-05 7.87E-06 3.19E-06

0.

1.49E-05 6.60E-05 5.54E-06 PM148M+O 9.82E-06 2.54E-06 l.94E-06

0.

3.85E-06 2.14E-04 4.18E-05 PM148 3.84E-07 6.37E-08 3.20E-08

0.

l.20E-07 3.91E-05 5.80E-05 PM149 3.44E-08 4.87E-09 1.99E-09

0.

9.19E-09 7.21E-06 2.50E-05 PM151 8.50E-09 1.42E-09 7.21E-10

0.

2.55E-09 3.94E-06 2.00E-05 SM151 8.59E-05 1.48E-05 3.55E-06

0.

1.66E-05 4.45E-05 3.25E-06 SM153 l.?OE-08 l.42E-08 l.04E-09

0.

4.59E-09 4.14E-06 l.58E-05 EU152 2.38E-04 5.41E-05 4.76E-05

0.

3.35E-04 3.43E-04 1.59E-05 EU154 7.40E-04 9.lOE-05 6.48E-05

0.

4.36E-04 5.84E-04 3.40E-05 EU155 l.OlE-04 l.43E-05 9.21E-06

0.

6.59E-05 9.46E-05 5.95E-06 EU156 l.93E-06 l.48E-06 2.40E-07

0.

9.95E-07 8.56E-05 4.50E-05 TB160 2.21E-05 0.

2.75E-06

0.

9.lOE-06 l.92E-04 2.68E-05 H0166M 3.37E-04 1.0SE-04 8.00E-05

0.

l.57E-04 3.94E-04 l.59E-05 Wl81 6.23E-09 2.03E-09 2.17E-10

0.
0.

l.71E-06 2.53E-07 Wl85 l.95E-07 6.47E-08 6.81E-09

0.
0.

5.57E-05 l.07E-05 Wl87 l.06E-09 8.85E-10 3.lOE-10

0.
0.

3.63E-06 l.94E-05 53

PALISADES NUCLEAR PLANT OFFSITE DOSE CALCULATION MANUAL Revision 9 TABLE 1.7 (contd)

ADULT INHALATION DOSE COMMITMENT FACTORS CMREM/50Y PER PCI INHALED IN FIRST YR)

ISOTOPE BONE LIVER TOTAL BODY THYROID KIDNEY LUNG GI-LLI PB210+0 2.64E-02 6.73E-03 8.37E-04

0.

2.12E-02 2.62E-02 3.65E-05 81210+0

0.

1.59E-06 1.32E-07

0.

1.92E-05 1.llE-03 2.95E-05 P0210 3.97E-04 8.60E-04 9.58E-05

0.

2.95E-03 3.14E-02 4.19E-05 RN222+0

0.
0.
0.
0.
0.

2.05E-06 0.

RA223+0 l.80E-04 2.77E-07 3.60E-05

0.

7.85E-06 2.55E-02 2.84E-04 RA224+0 l.98E-05 4.78E-08 3.96E-06

0.

1.35E-06 8.77E-03 3.0lE-04 RA225+0 3.00E-04 3.56E-07 5.99E-05

0.

1.0lE-05 2.92E-02 2.71E-04 RA226+0 1.25E-01 2.39E-06 9.14E-02

0.

6.77E-05 1.17E-Ol 2.94E-04 RA228+0 4.41E-02 1.23E-06 4.78E-02

0.

3.48E-05 1.61E-01 5.00E-05 AC225 4.23E-04 5.82E-04 2.84E-05

0.

6.63E~05 2.21E-02 2.52E-04 AC227+0 2.30E+OO 3.05E-01 1.36E-01

0.

9.82E-02 2.41E-01 5.08E-05 TH227+0 2.17E-04 3.92E-06 6.25E-06

0.

2.22E-05 3.77E-02 3.34E-04 TH226+0 2.00E-01 3.39E-03 6.77E-03

0.

1.89E-02 1.0lE+OO 3.49E-04 TH229 8.88E+OO 1.33E-01 4.36E-01

0.

6.52E-01 3.49E+OO 3.17E-04 TH230 2.29E+OO 1.31E-01 6.36E-02

0.

6.40E-01 6.21E-01 3.73E-05 TH232+0 2.56E+OO 1.12E-01 9.04E-02

0.

5.47E-01 5.96E-01 3.l?E-05 TH234 1.63E-06 9.56E-08 4.?0E-08

0.

5.41E-07 1.89E-04 7.03E-05 PA231+0 5.08E+OO 1.91E-01 1.98E-01

0.

1.07E+OO 5.75E-02 4.44E-05 PA233 1.21E-06 2.42E-07 2.09E-07

0.

9.15E-07 3.52E-05 1.02E-05 U232+0 5.14E-02 0.

3.66E-03

0.

5.56E-03 2.22E-01 4.21E-05 U233+0 1.09E-02 0.

6.60E-04

0.

2.54E-03 5.32E-02 3.89E-05 U234 1.04E-02 0.

6.46E-04

0.

2.49E-03 5.22E-02 3.81E-05 U235+0 1.00E-02 0.

6.0?E-04

0.

2.34E-03 4.90E-02 4.84E-05 U236 l.OOE-02 0.

6.20E-04

0.

2.39E-03 5.00E-02 3.57E-05 U237 3.67E-08 0.

9.77E-09

0.

1.51E-07 1.02E-05 1.20E-05 U238+0 9.58E-03 0.

5.67E-04

0.

2.18E-03 4.58E-02 3.41E-05 NP237+0 1.69E+OO 1.47E-01 6.87E-02

0.

5.lOE-01 5.22E-02 4.92E-05 NP238 2.96E-07 8.00E-09 4.61E-09

0.

2.72E-Oa 1.02E-05 2.13E-05 NP239 2.87E-08 2.82E-09 1.55E-09

0.

8.75E-09 4.?0E-06 1.49E-05 PU238 2.74E+OO 3.87E-01 6.90E-02

0.

2.96E-01 1:82E-01 4.52E-05 PU239 3.19E+OO 4.31E-01 7.75E-02

0.

3.30E-01 1.72E-01 4.13E-05 PU240 3.18E+OO 4.30E-01 7.73E-02

0.

-3.29E-01 1.72E-01 4.21E-05 PU241+0 6.41E-02 3.28E-03 1.29E-03

0.

5.93E-03 1.52E-04 8.65E-07 PU242 2.95E+OO 4.15E-01 7.46E-02

0.

3.l?E-01 1.65E-01 4.05E-05 PU244 3.45E+OO 4.76E-Ol 8.54E-02

  • 0.

3.64E-01 1.89E-01 6.03E-05 AM241 1.0lE+OO 3.59E-01 6.71E-02

0.

5.04E-01 6.06E-02 4.60E-05 AM242M 1.02E+OO 3.46E-01 6.73E-02

0.

5.0lE-01 2.44E-02 5.79E-05 AM243 1.0lE+OO 3.47E-Ol 6.57E-02

0.

4.95E-01 5.75E-02 5.40E-05 CM242 1.48E-02 1.51E-02 9.84E-04

0.

4.48E-03 3.92E-02 4.91E-05 CM243 7.86E-01 2.97E-01 4.61E-02

0.

2.15E-01 6.31E-02 4.84E-05 CM244 5.90E-01 2.54E-01 3.51E-02

0.

1.64E-01 6.06E-02 4.68E-05 CM245 l.26E+OO 3.59E-01 7.14E-02

0.

3.33E-01 5.85E-02 4.36E-05 CM246 l.25E+OO 3.59E-Ol 7.13E-02

0.

3.33E-01 5.96E-02 4.29E-05 CM247+0 1.22E+OO 3.53E-01 7.03E-02

0.

3.28E-01 5.85E-02 5.63E-05 CM248 l.OlE+Ol 2.91E+OO 5.79E-01

0.

2.70E+OO 4.82E-01 9.09E-04 CF252 9.78E-01 0.

2.33E-02

0.
0.

1.99E-Ol l.78E-04 54

I PALISADES NUCLEAR PLANT OFFSITE DOSE CALCULATION MANUAL Revision 9 TABLE 1.8 EXTERNAL DOSE FACTORS FOR STANDING ON CONTAMINATION GROUND {DFG1l

{MREM/HR PER PCI/M2)

ELEMENT TOTAL BODY SKIN H-3 0.0 0.0 C-14 0.0 0.0 Na-24 2.50E-08 2.90E-08 P-32 0.0

0. o-Cr-51 2.20E-10 2.60E-10 Mn-54 5.80E-09 6.80E-09 Mn-56
l. lOE-08 l.30E-08 Fe-55 0.0 0.0 Fe-59 8.00E-09 9.40E-09 Co-58 7.00E-09 8.20E-09 Co-60 l.70E-08 2.00E-08 Ni-63 0.0 0.0 Ni-65 3.70E-09 4.30E-09 Cu-64 l.50E-09
1. 70E-09 Zn-65 4.00E-09 4.60E-09 Zn-69 0.0 0.0 Br-83 6.40E-ll 9.30E-ll Br-84 l.20E-08 l.40E-08 Br-85 0.0 0.0 Rb-86 6.30E-10 7.20E-10 Rb-88 3.50E-09 4.00E-09 Rb-89
1. 50E-08 l.80E-08 Sr-89 5.60E-13 6.50E-13 Sr-91 7.lOE-09 8.30E-09 Sr-92 9.00E-09 l.OOE-08 Y-90 2.20E-12 2.60E-12 Y-9lm 3.80E-09 4.40E-09 Y-91 2.40E-ll 2.70E-ll Y-92 l.60E-09 1.90E-09 Y-93 5.70E-10 7.80E-10 Zr-95 5.00E-09 5.80E-09 Zr-97 5.50E-09 6.40E-09 Nb-95 5.lOE-09 6.00E-09 Mo-99 l.90E-09 2.20E-09 Tc-99m 9.60E-10
l. lOE-09 Tc-101 2.70E-09 3.00E-09 Ru-103 3.60E-09 4.20E-09 Ru-105 4.50E-09 5.lOE-09 Ru-106

-1. 50E-09 l.80E-09 Ag-llOm

1. 80E-08 2.lOE-08 Te-125m 3.50E-ll
4. 80E-11 Te-127m
l. lOE-12 l.30E-12 Te-127 l.OOE-11 l.lOE-11 55

PALISADES NUCLEAR PLANT OFFSITE DOSE CALCULATION MANUAL Revision 9 TABLE 1.8 (continued)

EXTERNAL DOSE FACTORS FOR STANDING ON CONTAMINATION GROUND CDFGrl CMREM/HR PER PCI/M2 )

ELEMENT Te-129m Te-129 Te-13lm Te-131 Te-132 I-130 I-131 I-132

. I -133 I-134 I-135 Cs-134 Cs-136 Cs-137 Cs-138 Ba-139 Ba-140 Ba-141 Ba-142 La-140 La-142 Ce-141 Ce-143 Ce:_l44 Pr-143 Pr-144 Nd-147 W-187 Np-239 TOTAL BODY 7.70E-10 7.lOE-10 8.40E-09 2.20E-09

1. 70E-09 l.40E-08 2.80E-09
1. ?OE-08 3.?0E-09 l.60E-08 l.20E-08 l.20E-08 l.50E-08 4.20E-09 2.lOE-08 2.40E-09 2.lOE-09 4.30E-09 7.90E-09 l.50E-08 1.50E-08 5.50E-10 2.20E-09 3.20E-10 0.0 2.00E-10 l.OOE-09 3.lOE-09 9.50E-10 56 SKIN 9.00E-10 8.40E-10 9.90E-09 2.60E-06 2.00E-09
1. 70E-08 3.40E-09 2.00E-08 4.50E-09 l.90E-08 l.40E-08 l.40E-08 l.70E-08 4.90E-09 2.40E-08 2.70E-09 2.40E-09 4.90E-09 9.00E-09 l.70E-08 l.80E-08 6.20E-10 2.50E-09 3.?0E-10 0.0 2.30E-10 l.20E-09 3.60E-09 l.lOE-09

PALISADES NUCLEAR PLANT OFFSITE DOSE CALCULATION MANUAL l

Revision 9 TABLE 1. 9 1995 PALISADES GASEOUS DESIGN

  • OBJECTIVE ANNUAL QUANTITIES Design Objective Dose Factor Annual Quantity Nuclide Organ Mrem/Ci

~en Ag-llOm GI Tract-T

1. llE+OO
1. 35E+Ol Ar-41 Total Body 3.53E-04
1. 42E+04 Ba-139 GI Tract-C 3.02E-03 4.97E+03 Ba-140 Lung-T
1. 06E-01
1. 42E+02 Br-82 Total Body-I
1. 40E-03 3.57E+03 C-14 Bone-C 1.39E-01 1.08E+02 Ce-141 GI Tract-T 1.22E-01 1.23E+02 Ce-144 GI Tract-T 3.25E+OO 4.62E+OO Co-57 GI Tract-T 8.32E-02
1. 80E+02 Co-58 Total Body-C 4.88E-02 1.02E+02 Co-60 Total Body-C 2.91E-01
1. 72E+Ol Cr-51 GI Tract-A.T 2.27E-03 6.61E+03 Cs-134 Liver-C 6.70E+OO 2.24E+OO Cs-136 Total Body-I 7.87E-02 6.35E+Ol Cs-137 Bone-C 6.54E+OO 2.29E+OO Cs-138 Total Body-C 2.90E-05
1. 72E+05 Fe-55 Bone-C 2.00E-01 7.50E+Ol Fe-59 GI Tract-T 2.33E-Ol 6.44E+Ol H-3 Total Body-C l.59E-04 3.14E+04 I-131 Thyroid-I 7.87E+OO
1. 91E+OO I-132 Thyroi d-C
1. 06E-02 1.42E+03 I-133 Thyroid-C 2.lOE-01 7.14E+Ol I-134 Thyroid-C 2.77E-03 5.42E+03 I-135 Thyroid-C 4.33E-02 3.46E+02 Kr-83m Skin 8.56E-07 l.75E+07 Kr-85 Skin 7.72E-05 l.94E+05 Kr-85m Total Body 4.67E-05
1. 07E+05 Kr-87 Skin 8.29E-04 l.81E+04 Kr-88 Total Body 5.87E-04 8.52E+03 Kr-89 Total Body 6.63E-04 7.54E+03 La-140 GI Tract-T 2.55E-02 5.88E+02 Mn-54 GI Tract-T 2.35E-Ol 6.38E+Ol Mn-56 GI Tract-C 6.44E-03 2.33E+03 Mo-99 GI Tract-T l.41E-02 1.06E+03 N-13 Total Body-C 4.SlE-06 1.11E+06 Na-24 Total Body-C 8.42E-04
5. 94E+03.

Nb-95 GI Tract-T l.05E-01

1. 43E+02 Ni-65 GI Tract-C 4.39E-03 3.42E+03 Ng-239 GI Tract-T 6.90E-03 2.17E+03 R -88 Total Body-C 1.92E-05 2.60E+05 Ru-103 GI Tract-T
1. 33E-Ol l.13E+02 Ru-105 GI Tract-C 5.21E-03 2.88E+03 Sb-124 GI Tract-T 7.49E-Ol 2.00E+Ol Sb-125 GI Tract-T 4.23E-Ol 3.55E+Ol 57

PALISADES NUCLEAR PLANT OFFSITE DOSE CALCULATION MANUAL I

J Revision 9 TABLE 1*9 {contd}

1995 PALISADES GASEOUS DESIGN OBJECTIVE ANNUAL QUANTITIES Design Objective Dose Factor Annual Quantity Nuclide Organ Mrem/Ci (Ci )

Sr-89 Bone-C 8.79E+OO

1. 71E+OO Sr-90 Bone-C 3.61E+02 4.16E-02 Sr-91 Bone-I 2.14E+OO 7.0lE+OO Sr-92 GI Tract-C 1.27E-02 1.18E+03 Tc-99m GI Tract-T 3.21E-04 4.67E+04 Tc-101 GI Tract-I 4.42E-05 3.39E+05 Te-127 GI Tract-T 4.23E-03 3.55E+03 Xe-131m Skin 3.41E-05 4.40E+05 Xe-133 Total Body 1.17E-05 4.27E+05 Xe-133m Skin 7.12E-05 2.11E+05 Xe-135 Total Body 7.23E-05 6.92E+04 Xe-135m Total Body
1. 25E-04 4.00E+04 Xe-137 Skin 7.63E-04
1. 97E+04 Xe-138 Total Body 3.53E-04 1.42E+04 Zn-65 Total Body-C 4.42E-01 1.13E+Ol Zr-95 GI Tract-T 3.08E-01 4.87E+Ol 58

l PALISADES NUCLEAR PLANT OFFSITE DOSE CALCULATION MANUAL Revision 9 I I.

A.

LIQUID EFFLUENTS CONCENTRATION

1.

Requirements

2.

Appendix A.Section III.G requires that the concentration of radioactive material released at any time from the site to unrestricted areas shall be limited to ten times the Effluent Concentration (EC) specified in 10 CFR 20. Appendix B. Table 2.

Column 2 for nuclides other than dissolved or entrained noble gases.

For dissolved-or entrained noble gases. the concentration shall be limited to 2E-04 µCi/ml total activity.

To ensure compliance. the following approach will be used for each release.

Prerelease Analysis Most tanks wi 11 be recirculated through two volume changes prior to sampling for release to the environment to ensure that a representative sample is obtained.

The appropriate recirculation time for those tanks too large to provide two volume changes will be the time that the suspended particulate concentration reaches steady state. Either a one-time test. or prior sampling data. may be used to determine appropriate recirculation time.

Prior to release. a grab sample will be analyzed for each release.

and the concentration of each radionuclide determined.

n c =: E Ci i =1 where:

(2.1)

C Total concentration in the liquid effluent at the release point. µCi/ml.

C; Concentration of a single radionuclide i. µCi/ml.

59

PALISADES NUCLEAR PLANT OFFSITE DOSE CALCULATION MANUAL Revision 9


~

3.

Effluent Concentration (EC) - Sum of the Ratios

  • The EC-Fraction (Rj) for each release point will be calculated by the relationship defined by Note 4 of Appendix B. 10 CFR 20:

'°'

Ci R* = L.J

~ 10.0 J

. l ECi (2.2) where:

C; Effluent concentration of radionuclide i. µCi/ml.

The EC of radionuclide i. 10 CFR 20. Appendix B. Table 2.

Column 2 - µCi/ml.

=

Rj The Total EC-Fraction for the release point.

The sum of the ratios at the discharge to the lake must be s 10 due to the releases from any or all concurrent releases.

The following relationship will assure this criterion is met:

f 1 (R1 -l) + f 2 (R2-l) + f 3 (R3 -l)

~ F where:

(2.3)

=

=

F

=

The effluent flow rate (gallons/minute) for the respective releases. determined by Plant personnel.

The Total EC-Fractions for the respective releases as determined by Equation 2.2.

Minimum required dilution flow rate. Normally, a conservatively high dilution flow rate is used. that is. flow rate used= (b;)(F) where b; is a conservative factor greater than 1.0.

60

PALISADES NUCLEAR PLANT i

OFFSITE DOSE CALCULATION MANUAL

~

Revision 9 B.

INSTRUMENT SETPOINTS

1.

Setpoint Determination Appendix A.Section III.F requires alarm setpoints for each liquid effluent monitor will be established using Plant instructions to ensure the requirements of Appendix A.Section III.Gare not exceeded. Concentration. flow rate. dilution. principal gamma emitter. geometry. and detector efficiency are combined to give an equivalent setpoint in counts per minute (cpm).

The identification number for each liquid effluent radiation detector is contained in Figure 2-2.

The respective alarm/trip setpoints at each release point will be set such that the sum of the ratios at each point. as calculated by Equation 2.2. will not be exceeded.

The value of R is directly related to the total concentration calculated by Equation 2.1.

An increase in the concentration would indicate an increase in the value of R.

A large increase would cause the limits specified in Section 2.1.1 to be exceeded.

The minimum alarm/trip setpoint value is equal to the release concentration. but for ease of operation it may be desired that the setpoint (S) be set above the effluent concentration (C) by the same factor (b) utilized in setting dilution flow.

That is:

S=bxC Liquid effluent flow paths and release points are indicated in Figure 2.1.

2.

Composite Samplers (2.4)

Effluent pathways. Turbine Sump and Service Water. are equipped with continuous compositors to meet the requirements of Appendix A.

Table D-1.

These compositors are adjustable and normally set in a time mode and collect three to six samples hourly, 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> a day with a total collection of approximately one gallon per day. A representative sample is collected daily from the compositor and saved for the weekly. monthly analysis requirements of Appendix A.

Table D-1.

In the event that a compositor is not operational.

effluent releases via this pathway may continue provided that grab samples are collected and analyzed for gross beta or gamma radioactivity at least once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> per Appendix A. Table C-1.

Action 3.

61

PALISADES NUCLEAR PLANT OFFSIJE DOSE CALCULATION MANUAL Revision 9

3.

Post-Release Analysis C.

DOSE A post-release analysis will be done using actual release data to ensure that the limits specified in Section 1 were not exceeded.

A composite list on concentrations (C;). by isotope. will be used with the actual liquid radwaste (f) and dilution (F) flow rates (or volumes) during the release.

The data will be substituted into Equation 2.3 to demonstrate compliance with the limits in Section 1.

This data and setpoints will be recorded in auditable records by Plant personnel.

1.

RETS Requirement Appendix A.Section III.H.l requires that the quantity of radionuclides released by limited such that the dose or dose commitment to an individual from radioactive materials in liquid effluents release to unrestricted areas from the reactor (see Figure 2-1) will not exceed:

I *

a.

During any calendar quarter. 1.5 mrem to the total body and

~

5 mrem to any organ. and

b.

During any calendar year. 3 mrem to the total body and 10 mrem to any organ.

To ensure compliance. quantities of activity of each radionuclide released will be summed for each release and accumulated for each quarter as follows in Section 2.

2.

Release Analysis Calculations shall be performed for each batch release. and weekly for continuous releases according to the formula:

~ A./c. ~ 0.5 1

J.

J.

where:

(2.5)

Cumulative quarterly activity of nuclide i identified in liquid release (C;).

Design objective annual quantity of radionuclide i from Table 2.2.

62

J PALISADES NUCLEAR PLANT OFFSITE DOSE CALCULATION MANUAL Revision 9 The design basis quantities are derived in such a conservative manner that doses may be greatly overestimated by this technique.

As a consequence of this conservatism. and in light of historically consistent operations with releases well below annual design basis quantities. the Appendix A. effluent requirements do not require monthly dose projections.

Instead. if at any time. calculations by Equation (2.5) results in values greater than 0.5 for a given quarter or 1.0 for year-to-date. the NRC LADTAP code will be run to ensure that Appendix A.Section III.H.l has been met.

Values for the design basis quantities (Ci). and the dose per Curie CDc/Cc)i for each nuclide i shown in Table 2.2. were calculated as follows in Sections 2.1 and 2.2.

a.

Water Ingestion The dose to an individual from ingestion of radioactivity from any source as described by the following equation:

l DJ. °"'

(DCF).. x I.

~

l.J

l.

i=l where:

=

(2.6)

Dose for the jth organ from radionuclides releases.

mrem.

The organ of interest.

Ingestion dose commitment factor for the jth organ from the ;th radionuclide mrem/pCi. see Table 2.1.

Activity ingested of the ith radionuclide. pCi.

Ii is described by:

I (AJ (V) (365)

(1E06) i (1000) (d)

(2. 7) where:

365 Days per year.

A; Annual activity released of ith radionuclide. µCi.

v d

Average rate of water consumption (2000 ml/d - adult.

1400 ml/d - teen and child. 900 ml/d - infant.

ICRP 23. p 358).

Dilution water flow for year. ml.

63

PALISADES NUCLEAR PLANT OFFSITE DOSE CALCULATION MANUAL Revision 9 1000 =

Dispersion factor from discharge to nearest drinking water supply.

1E06 =

Conversion µCi to pCi.

The dose equation then becomes:

D (3.65E05) (V) j d

b.

Fish Ingestion i

~ (DCF) ij x Ai mrem i=l (2.8)

The dose to an individual from the consumption of fish is described by Equation 2.10.

In this case the activity ingested of the ;th radionuclide CI;) is described by:

AiBiF(lE09)

I. =

= pCi

l.

15d where:

=

Annual released of ;th radionuclide. µCi.

Fish concentration factor of ;th radionuclide (see Table 2.0).

(2.9)

µCi/gm

µCi/ml F

=

Amount of fish eaten per year (21 kg adult. 16 kg teen. 6.9 kg child. none infant).

15

=

Dispersion factor from discharge to fish exposure point.

d

=

1E09 =

Dilution water flow for year. ml.

Conversion of µCi and Kgm to gross.

Substitution of Equation 2.9 into Equation 2.6 gives:

i (6.7E07)F ~

Dj =

d

~ Ai x Bi x DCFi mrem i=l 64 (2.10)

~ - J

(

  • I C.

PALISADES NUCLEAR PLANT OFFSITE DOSE CALCULATION MANUAL Revision 9 Annual Analysis A complete analysis utilizing the NRC computer code LADTAP with the total source release will be done annually in conjunction with the annual environmental report. This analysis will provide estimates of dose to the total body and various organs in addition to the dose limiting organs considered in the method of Section 2.

The following approach is utilized on LADTAP.

The dose to the jth organ from m radionuclides. Dj. is described by:

m Dj = L Dij mrem i=l m

= ~ (DCF) ij x Ij mrem i=l (2.11) where:

Dj j

=

Dose to the j~ organ from the i~ radionuclide. mrem.

The organ of interest (bone. GI tract. thyroid.

liver. kidney, lung, or total body).

(OCF);j

=

Adult ingestion dose commitment factor for the jth organ from the ;th radionuclide. mrem/pCi (see Table 2.1).

=

Activity ingested of the ;th radionuclide. µCi.

I; for water ingestion is described by:

A. Vr I. =

i uCi i

vd r-(2.13) and for fish ingestion I; is described by:

A. B. Fr I. =

i i

µCi

l.

v d where:

v r

v Activity release of jth radionuclide during the year.

µCi.

Average rate of water consumption (2000 ml/d).

Number of days during the year (365 d).

Dispersion factor from point of discharge to point of exposure.

65

PALISADES NUCLEAR PLANT OFFSITE DOSE CALCULATION MANUAL Revision 9 d

Dilution water volume (ml).

I

  • Fish concentration factor of the ;th radionuclide.

µCi/gm

µCi/ml

=

F

=

Amount of fish eaten per day (57.5 gm/d).

D.

OPERABILITY OF LIQUID RADWASTE EQUIPMENT The Palisades liquid radwaste system is designed to reduce the radioactive materials in liquid wastes prior to their discharge (by recycle or shipment for disposal) so that radioactivity in liquid effluent releases to unrestricted areas (see Figure 2-1) will not exceed the limits of Appendix A. III.H.1. Maintaining the cumulative fraction if allowable release for each batch release and weekly for continuous releases assures compliance with this requirement.

In addition. 13 years of operating experience (to the date this ODCM was first adopted) has shown that design basis quantities never have been exceeded.

E.

RELEASE RATE FOR OFFSITE EC (50 mRem/yr) 10 CFR 20.1302 requires radioactive effluent releases to unrestricted areas be less than the limits specified in Appendix B. Table 2 when averaged over a period not to exceed one year. Concentrations at this level. if ingested for one year. will result in a dose of 50 millirem to the total body.

In addition. 10 CFR 50.36a requires that the release of radioactive materials be kept as low as is reasonably achievable.

Appendix I to 10 CFR 50 provides the numerical guidelines on limiting conditions for operations to meet the as low as is reasonably achievable requirement.

The LADTAP code has been run to determine the dose due to drinking water at Plant discharge concentration (1.000 x nearest drinking water intake concentration.) The source term used is given in Table 1.1.

Dose to the most limiting organ of the person hypothetically drinking this water is 3.BBE-03 mrem.

The release rate which would result in a dose rate equivalent to 500 mrem/year (using the more conservative total body limit) is the curies/year given in Table 1.1 (162) times 500/3.BBE-03 or 2.1E07 Ci/yr= 0.661 Ci/sec.

F.

FIGURES AND TABLES 66

\\

I

/

\\

/

13 I

./

s.

n~

\\

/

I

\\

I 8

/

...-t

'lJ I

\\

I

/

n;

~)

\\

\\

I

/

\\

f I

/

I

/

\\

I

/

, I

\\

I

/

/

I

\\

I

/

\\ \\

\\

0

/

I I

/

/

_J

~

I

/

14

<(

NNW NHI

/

J

~ \\

I

z

\\

/

I- <(

HW I

HI

/

z: ::::E

/

s :z:

\\

/

0.... 0 WHW j(

1-1

~ ~ j 181 elev.

CJ'\\

  • ~-

w t::

_J ::J 0

r--..

u u

  • r-

\\.0

J _J VJ
z: <(
  • r-SUflfACE 586 elev.

\\ \\

u I I

\\

(/)

Q)

\\

w w 0:::

WSW I

\\

ISi Cl (/)

<( 0 I

\\

(/) Cl

\\

\\

1-1 I

_J w

\\

~

H

<( I-I 0.... 1-1

\\

\\

(/)

HW.

\\

\\

LL.

5SI LL.

\\

0

~

I

\\

i
I

\\

\\

617

~

'I' I

\\

\\

\\

~

I

~

I

\\

\\

t"* 715 M£TERS

\\

\\

AN I

\\

\\

tlNll(STnlCfEO AAl:A I

SllE BOUNDARY

\\

&19\\

SITE ENVIRONMENT I

\\

18.

TLO STATIONS A20 PALISADES NUCLEAR PLANT SITE BOUNDARY flGllRE l'. I


-**-- ----~-------------

_J

<(

z:

I- <(

z: :E
s :z:

a_ 0 0:::

~ °'

~

<(

w r;::

_J :::>

0 u u

> _J
z: <(

I/)

u

(/)

(!)

w w 0:::

Cl (/)

<( 0

(/) Cl

_J w

<( I-a_........

(/)

LL LL..

0.

PALISADES RADWASTE EFFLUENTS - LIQUID cu J\\I" WI\\~ T(

WSllM rnrAHn Wl\\STf Tl\\NKSli'I PRIMARY SYSTEM STORAGE TANK T!IO TRIP I HOW CONTROL r---.,

I


L-------'---+---,r----1 RE 1049 t--1~--

MISf.fl I ANFOUS WASTE SYSTEM IDIRTV WASTrJ LAtJNOnv SYSTEM riurnrn WASTE TANK UTIUTY WAtER STORAGE TANK T-91 TURBINE BLDG DRAINS

~*~-

TURBINE SUMP STEAM GEN RE lllJJ SERVICE

- WATER ----..

RE52U DILUTION FLOW

  • 1; I

LAKE

  • .f,..

LAKE INLET SERVICE W_ATER -----'-------------w

J t

J I

c NA p

CR MN FE co NI cu ZN BR RB SR y

ZR NB MO TC RU RH TE I

cs BA LA CE PR ND w

NP

.. 69 FRESHWATER FISH 9.0E-01 4.6E 03

1. OE 02
1. OE 05 2.0E 02 4.0E 02
1. OE 02 5.0E 01
1. OE 02 5.0E 01 2.0E 03 4.2E 02 2.0E 03 3.0E 01 2.5E 01 3.3E 00 3.0E 04
1. OE 01
1. 5E 01
1. OE 01
1. OE 01 4.0E 02
1. 5E 01 2.0E 03 4.0E 00 2.5E 01
1. OE 00 2.5E 01 2.5E 01
1. 2E 03
1. OE 01

PALISADES NUCLEAR PLANT OFFSITE DOSE CALCULATION MANUAL Revision 9 TABLE 2.1 I

r I

I

  • INFANT INGESTION DOSE COMMITMENT FACTORS CMREM/SOY PER PCI INGESTED IN FIRST YR)

ISOTOPE H3 BElO Cl4 Nl3 Fl8 NA22 NA24 P32 AR39 AR41 CA41 SC46 CR51 MN54 MN56 FE55 FE59 C057 COSS C060 NI59 NI63 NI65 CU64 ZN65 ZN69M+D ZN69 SE79 BR82 BR83+D BR84 BR85 KR83M KR85M KR85 KR87 KRBB+D KR89 RB86 RB87 RB88 RB89+D SR89+D SR90+D SR91+0 SR92+0 BONE LIVER TOTAL BODY THYROID KIDNEY LUNG GI-LLI

0.

3.0BE-07 3.0BE-07 3.0BE-07 3.0BE-07 3.0BE-07 3.083-07 l.71E-05 2.49E-06 5.16E-07

0.

l.64E-06 0.

2.78E-05 2.37E-05 5.06E-06 5.06E-06 5.06E-06 5.06E-06 5.06E-06 5.06E-06 5.85E-08 5.85E-08 5.85E-08 5.835E-08 5.85E-08 5.85E-08 5.85E-08 5.19E-06 0.

4.43E.07

0.
0.
0.

l.22E-06 9.83E-05 9.83E-05 9.83E-05 9.83E-05 9.83E-05 9.83E-05 9.83E-05 l.OlE-05 l.OlE~os l.OlE-05 1.0lE-05 1.0lE-05 l.OlE-05 l.OlE-05 1.70E-03 1.00E-04 6.59E-05

0.
0.
0.

2.30E-05

0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.

3.74E-04 0.

4.0BE-05

0.
0.
0.

1.91E-07 3.75E-08 5.41E-08 l.69E-08

0.

3.56E-08 0.

3.53E-05

0.
0.

1.41E-08 9.20E-09 2.0lE-09 1.79E-08 4.llE-07

0.

1.99E-05 4.SlE-06

0.

4.41E-06 0.

7.31E-06

0.

8.lBE-07 l.41E-07

0.

7.03E-07

0.

7.43E-05 1.39E-05 8.98E-06 2.40E-06

0.
0.

4.39E-06 l.14E-06 3.0BE-05 5.38E-05 2.12E-05

0.
0.

1.59E-05 2.57E-05

0.

1.lSE-06 1.87E-06

0.
0.
0.

3.92E-06

0.

3.60E-06 8.98E-06

0.
0.
0.

8.97E-06

0.

1.0BE-05 2.55E-05

0.
0.
0.

2.57E-05 4.78E-05 1.45E-05 8.17E-06

0.
0.
0.

7.16E-07 6.34E-04 3.92E-05 2.20E-05

0.
0.
0.

l.95E-06 4.70E-06 5.32E-07 2.42E-07

0.
0.
0.

4.0SE-05

0.

6.09E-07 2.82E-07

0.

1.03E-06 0.

l.25E-05 1.84E-05 6.31E-05 2.91E-05

0.

3.06E-05 0.

5.33E-05 l.50E-06 3.06E-06 2.79E-07

0.

1.24E-06 0.

4.24E-05 9.33E-08 1.68E-07 1.25E-08

0.

6.98E-08 0.

1.37E-05

0.

2.lOE-05 3.90E-06

0.

2.43E-05 0.

5.58E-07

0.
0.

1.27E-05

0.
0.
0.
0.
0.
0.

3.63E-07

0.
0.
0.
0.
0.
0.

3.82E-07

0.
0.
0.
0.
0.
0.

1.94E-08

0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.

1.70E-04 8.40E-05

0.
0.
0.

4.35E-06

0.

8.BBE-05 3.52E-05

0.
0.
0.

5.98E-07

0.

4.98E-07 2.73E-07

0.
0.
0.

4.BSE-07

0.

2.86E-07 l.97E-07

0.
0.
0.

9.74E-08 2.51E-03 0.

7.20E-05

0.
0.
0.

5.16E-05 l.85E-02 0.

4.71E-03

0.
0.
0.

2.31E-04 *.

5.00E-05 0.

l.BlE-06

0.
0.
0.

5.92E-05 l.92E-05 0.

7.13E-07

0.
0.
0.

2.07E-04 70

J.

I I

I PALISADES NUCLEAR PLANT OFFSITE DOSE CALCULATION MANUAL Revision 9 TABLE 2.1 INFANT INGESTION DOSE COMMITMENT FACTORS (MREM/50Y PER PCI INGESTED IN FIRST YR)

ISOTOPE BONE LIVER TOTAL BODY THYROID KIDNEY LUNG GI-LLI Y90 8.69E-08 0.

2.33E-09

0.
0.
0.

1.20E-04 Y91M+D 8.lOE-10 0.

2.76E-11

0.
0.
0.

2.70E-06 Y91 1.13E-06 0.

3.0lE-08

0.
0.
0.

8.lOE-05 Y92 7.65E-09 0.

2.15E-10

0.
0.
0.

l.46E-04 Y93 2.43E-08 0.

6.62E-10

0.
0.
0.

1.92E-04 ZR93+0 1.93E-07 9.18E-08 5.54E-08

0.

2.71E-07

0.

2.39E-05 ZR95+0 2.06E-07 5.02E-08 3.56E-08

0.

5.41E-08 0.

2.50E-05 ZR97+0 l.48E-08 2.54E-09 1.16E-09

0.

2.56E-09 0.

1.62E-04 NB93M 1.23E-07 3.33E-08 l.04E-08

0.

3.25E-08 0.

3.98E-06 NB95 4.20E-08 1.73E-08 1.00E-08

0.

1.24E-08 0.

1.46E-05 NB97 4.59E-10 9.79E-11 3.53E-11

0.

7.65E-11 0.

3.09E-05 M093

0.

5.65E-05 1.82E-06

0.

1.13E-05 0.

1.21E-06 M099+0

0.

3.40E-05 6.63E-06

0.

5.08E-05 0.

1.12E-05 TC99M l.92E-09 3.96E-09 5.lOE-08

0.

4.26E-08 2.07E-09 l.15E-06 TC99 l.08E-06 1.46E-06 4.55E-07

0.

l.23E-05 l.42E-07 6.31E-06 TClOl 2.27E-09 2.86E-09 2.83E-08

0.

3.40E-08 1.56E-09 4.86E-07 RU103+D 1.48E-06 0.

4.95E-07

0.

3.08E-06 0.

l.80E-05 RU105+D 1.36E-07 0.

4.58E-08

0.

1.00E-06 0.

5.41E-05 RU106+D 2.41E-05 0.

3.0lE-06

0.

2.85E-05 0.

l.83E-04 RH105 1.09E-06 7.13E-07 4.79E-07

0.

1.98E-06 0.

1.77E-05 PD107

0.

l.19E-06 8.45E-08

0.

6.79E-06 0.

9.46E-07 PD109

0.

1.50E-06 3.62E-07

0.

5.51E-06 0.

3.68E-05 AGllOM+D 9.96E-07 7.27E-07 4.81E-07

0.

1.04E-06 0.

3.77E-05 AGlll 5.20E-07 2.02E-07 l.07E-07

0.

4.22E-07 0.

4.82E-05 CD113M

0.

l.77E-05 6.52E-07

0.

l.34E-05 0.

2.66E-05 CD115M

0.

1.42E-05 4.93E-07

0.

7.41E-06 0.

8.09E-05 SN123 2.49E-04 3.89E-06 6.50E-06 3.91E-06 0.

0.

6.58E-05 SN125+D 7.41E-05 l.38E-06 3.29E-06 1.36E-06 0.

0.

l.llE-04 SN126+D 5.53E-04 7.26E-06 l.80E-05 1.91E-06 0.

0.

2.52E-05 SB124 2.14E-05 3.15E-07 6.63E-06 5.68E-08 0.

1.34E-05 6.60E-05 SB125+0 l.23E-05 l.19E-07 2.53E-06 1.54E-08 0.

7.72E-06 l.64E-05 SB126 8.06E-06 1.58E-07 2.91E-06 6.19E-08 0.

5.07E-06 8.35E-05 SB127 2.23E-06 3.98E-08 6.90E-07 2.84E-08 0.

l.15E-06 5.91E-05 TE125M 2.33E-05 7.79E-06 3.15E-06 7.84E-06 0.

0.

l.llE-05 TE127M+D 5.85E-05 l.94E-05 7.08E-06 l.69E-05 l.44E-04 0.

2.36E-05 TE127 l.OOE-06 3.35E-07 2.15E-07 8.14E-07 2.44E-06 0.

2.lOE-05 TE129M+D 1.00E-04 3.43E-05 1.54E-05 3.84E-05 2.50E-04 0.

5.97E-05 TE129 2.84E-07 9.79E-08 6.63E-08 2.38E-07 7.07E-07 0.

2.27E-05 TE131M+D l.52E-05 6.12E-06 5.05E-06 1.24E-05 4.21E-05 0.

l.03E-04 TE131+0 l.76E-07 6.50E-08 4.94E-08

  • 1.57E-07 4.50E-07 0.

7.llE-06 TE132+D 2.08E-05 l.03E-05 9.61E-06 l.52E-05 6.44E-05 0.

3.81E-05 TE133M+D 3.91E-07 l.79E-07 l.71E-07 3.45E-07 l.22E-06 0.

l.93E-05 TE134+D 2.67E-07 l.34E-07 l.38E-07 2.39E-07 9.03E-07

0.

3.06E-06 1129 2.86E-05 2.12E-05 l.55E-05 l.36E-02 2.51E-05 0.

4.24E-07 1130 6.00E-06 1.32E-05 5.30E-06 l.48E-03 l.45E-05 0.

2.83E-06 1131+0 3.59E-05 4.23E-05 l.86E-05 l.39E-02 4.94E-05 0.

l.51E-06 71

PALISADES NUCLEAR PLANT OFFSITE DOSE CALCULATION MANUAL I

I I

\\

Revision 9 TABLE 2.1 INFANT INGESTION DOSE COMMITMENT FACTORS (MREM/50Y PER PCI INGESTED IN FIRST YR)

ISOTOPE I132 1133+0 I134 I135+0 XE131M XE133M XE133 XE135M XE135 XE137 XE138+0 CS134M+D CS134 CS135 CS136 CS137+0 CS138 CS139+0 BA139 BA140+0 BA141+0 BA142+0 LA140 LA141 LA142 CE141 CE143+0 CE144+0 PR143 PR144 ND147+0 PM147 PM148M+D PM148 PM149 PM151 SM151 SM153 EU152 EU154 EU155 EU156 TB160 H0166M W181 W185 W187 BONE LIVER TOTAL BODY THYROID KIDNEY LUNG GI*LLI l.66E-06 3.37E-06 1.20E-06 l.58E-04 3.76E-06 0.

2.73E.06 l.25E-05 1.82E-05 5.33E-06 3.31E-03 2.14E-05 0.

3.08E-06 8.69E-07 l.78E-06 6.33E-07 4.15E-05 1.99E-06 0.

1.84E-06 3.64E-06 7.24E-06 2.64E-06 6.49E-04 8.07E-06 0.

2.62E-06

0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.

0..

0.
0.

l.76E-07 2.93E-07 1.48E-07

0.

1.13E-07 2.60E-08 2.32E-07 3.77E-04 7.03E-04 7.lOE-05

0.

l.81E-04 7.42E-05 1.91E-06 l.33E-04 1.21E-04 6.30E-06

0.

3.44E-05 1.31E-05 4.37E-07 4.59E-05 1.35E-04 5.04E-05

0.

5.38E-05 1.lOE-05 2.05E-06 5.22E-04 6.llE-04 4.33E-05

0.

1.64E-04 6.64E-05 1.91E-06 4.81E-07 7.82E-07 3.79E-07

0.

3.90E-07 6.09E-08 1.25E-06 3.lOE-07 4.24E-07 1.62E-07 0..

2.19E-07 3.30E-08 2.66E-08 8.81E-07 5.84E-10 2.55E-08

0.

3.51E-10 3.54E-10 5.58E-05 1.71E-04 1.71E-07 8.81E-06

0.

4.06E-08 1.05E-07 4.20E-05 4.25E-07 2.91E-10 1.34E-08

0.

1.75E-10 1.77E-10 5.19E-06 1.84E-07 l.53E-10 9.06E-09

0.

8.81E-11 9.26E-11 7.59E-07 2.llE-08 8.32E-09 2.14E-09

0.
0.
0.

9.77E-05 2.89E-09 8.38E-10 1.46E-10

0.
0.
0.

9.61E-05 1.lOE-09 4.04E-10 9.67E-11

0.
0.
0.

6.86E-05 7.87E-08 4.80E-08 5.65E-09

0.

1.48E-08 0.

2.48E-05 1.48E-08 9.82E-06 1.12E-09

0.

2.86E-09 0.

5.73E-05 2.98E-06 1.22E-06 1.67E-07

0.

4.93E-07 0.

1.71E-04 8.18E-08 3.04E-08 4.03E-09

0.

1.13E-08 0.

4.29E-05 2.74E-10 1.06E-10 1.38E-11

0.

3.84E-ll 0.

4.93E-06 5.53E-08 5.68E-08 3.48E-09

0.

2.19E-08 0.

3.60E-05 3.88E-07 3.27E-08 1.59E-08

0.

4.88E-08 0.

9.27E-06 1.65E-07 4.18E-08 3.28E-08

0.

4.80E-08 0.

5.443-05 6.32E-08 9.13E-09 4.60E-09

0.

1.09E-08 0.

9.74E-05 1.38E-08 1.81E-09 7.90E-10

0.

2.20E-09 0.

4.86E-05 6.18E-09 9.0lE-10 4.56E-10

0.

1.07E-09 0.

4.17E-05 2.90E-07 6.67E-08 1.44E-08

0.

4.53E-08 0.

5.58E-06 7.72E-09 5.97E-09 4.58E-10

0.

1.25E-09 0.

3.12E-05 6.74E-07 1.79E-07 1.51E-07

0.

5.02E-07 0.

1.59E-05 2.64E-06 3.67E-07 2.20E-07

0.

9.95E-07 0.

4.58E-05 5.42E-07 6.25E-08 3.23E-08

0.

1.40E-07 0.

8.37E-05 1.14E-07 7.06E-08 1.12E-08

0.

3.26E-08 0.

6.67E-05 2.59E-07 0.

3.24E-08

0.

7.37E-08 0.

3.45E-05 1.25E-06 2.69E-07 2.13E-07

0.

3.57E-07 0.

0.

8.85E-08 2.72E-08 3.04E-09

0.
0.
0.

3.82E-07 3.62E-06 1.13E-06 1.29E-07

0.
0.
0.

1.62E-05 9.03E-07 6.28E-07 2.17E-07

0.
0.
0.

3.69E-05 72

PALISADES NUCLEAR PLANT OFFSITE DOSE CALCULATION MANUAL Revision 9 TABLE 2.1 INFANT INGESTION DOSE COMMITMENT FACTORS (MREM/50Y PER PCI INGESTED IN FIRST YR)

ISOTOPE BONE LIVER TOTAL BODY THYROID KIDNEY LUNG GI* LU PB210+0 5.28E-02 1.42E-02 2.38E-03

0.

4.33E-02 0.

5.62E-05 BI210+D 4.16E-06 2.68E-05 3.58E-07

0.

2.08E-04 0.

5.27E-05 P0210 3.lOE-03 5.93E-03 7.41E-04

0.

1.26E-02 0.

6.61E-05 RN222+D

0.
0.
0.
0.
0.
0.
0.

RA223+0 4.41E-02 6.42E-05 8.82E-03

0.

1.17E-03 0.

3.43E-04 RA224+0 1.46E-02 3.29E-05 2.91E-03

0.

6.00E-04 0.

3.86E-04 RA225+0 5.78E-02 6.42E-05

1. lSE-02
0.

1.19E-03 0.

3.24E-04 RA226+0 6.20E-01 4.76E-05 5.14E-01

0.
8. 71E-04 0.

3.44E-04 RA228+0 4.32E-01 2.58E-05 4.86E-01

0.

4.73E-04 0.

5.86E-05 AC225 3.92E-05 5.03E-05 2.63E-06

0.

3.69E-06 0.

4.36E-04 AC227+0 4.49E-03 7.67E-04 2.79E-04

0.

1.56E-04 0.

8.SOE-05 TH227+0 1.20E-04 2.0lE-06 3.45E-06

0.

7.41E-06 0.

5.70E-04 TH228+0 2.47E-03 3.38E-05 8.36E-05

0.
1. 58E-04 0.

5.84E-04 TH229

1. 48E-02 1. 94E-04 7.29E-04
0.

9.29E-04 0.

5.31E-04 TH230 3.80E-03 1.90E-04

1. 06E-04
0.

9.12E-04 0.

6.24E-05 TH232+0 4.24E-03 1.63E-04 1.65E-04

0.

7.79E-04 0.

5.31E-05 TH234 6.92E-07 3.77E-08 2.00E-08

0.

1.39E-07 0.

1.19E-04 PA231+0 7.57E-03 2.SOE-04 3.02E-04

0.
1. 34E-03 0.

7.44E-05 PA233 3.llE-08 6.09E-09 5.43E-09

0.

1.67E-08 0.

1.46E-05 U232+0 2.42E-02

0.

2.16E-03

0.

2.37E-03 0.

7.04E-05 U233+0 5.08E-03 0.

3.87E-04

0.

l.08E-03 0.

6.SlE-05 U234 4.88E-03 0.

3.80E-04

0.

1.06E-03 0.

6.37E-05 U235+0 4.67E-03 0.

3.56E-04

0.

9.93E-04 0.

8.lOE-05 U236 4.67E-03 0.

3.64E-04

0.

1.0lE-03 0.

5.98E-05 U237 4.95E-07 0.

1. 32E-07
0.

1.23E-06 0.

2.llE-05 U238+0 4.47E-03 0.

3.33E-04

0.

9.28E-04 0.

5.71E-05 NP237+0 2.53E-03 1.93E-04 1.0SE-04

0.

6.34E-04 0.

8.23E-05 NP238 1.24E-07 3.12E-09 1.92E-09

0.

6.81E-09 0.

4.17E-05 NP239 1.llE-08 9.93E-10 5.61E-10

0.
1. 98E-09 0.

2.87E-05 PU238

1. 34E-03 1.69E-04 3.40E-05
0.
1. 21E-04 0.

7.57E-05 PU239 1.45E-03 1.77E-04 3.54E-05

0.
1. 28E-04 0.

6.91E-05 PU240

1. 45E-03 1. 77E-04 3.54E-05
0.

1.28E-04 0.

7.04E-05 PU241+0 4.38E-05 1.90E-06 8.82E-07

0.

3.17E-06 0.

1. 45E-06 PU242 1.35E-03 1. ?OE-04 3.41E-05
0.

1.23E-04 0.

6.77E-05 PU244 L57E-03 1:95E-04 3.91E-05

0.
1. 41E-04 0.
1. OlE-04 AM241 1.53E-03 7.18E-04 1.09E-04
0.

6.55E-04 0.

7.70E-05 AM242M 1.58E-03 7.02E-04 1.13E-04

0.

6.64E-04 0.

9.69E-05 AM243 1.SlE-03 6.88E-04 1.06E-04

0.

6.36E-04 0.

9.03E-05 CM242 1.37E-04 1. 24E-04 9.lOE-06

0.

2.62E-05 0.

8.23E-05 CM243 1.45E-03 6.88E-04 8.98E-05

0.

3.27E-04 0.

8.lOE-05 CM244 1.22E-03 6.16E-04 7.59E-05

0.
2. 71E-04 0.

7.84E-05 CM245 l.88E-03 7.49E-04 1.13E-04

0.

4.32E-04 0.

7.30E-05 CM246 1.87E-03 7.49E-04 1.13E-04

0.

4.31E-04 0.

7.17E-05 CM247+0

1. 82E-03 7.36E-04
1. llE-04
0.

4.24E-04 0.

9.43E-05 CM248

1. SlE-02 6.0?E-03 9.16E-04
0.

3.50E-03 0.

1. 52E-03 CF252 1.24E-03 0.

2.95E-05 0

0.
0.

2.99E-04 73

PALISADES NUCLEAR PLANT OFFSITE DOSE CALCULATION MANUAL I

f l

)

Revision 9 TABLE 2.1 CHILD INGESTION DOSE COMMITMENT FACTORS (MREM/50Y PER PCI INGESTED IN FIRST YR)

ISOTOPE BONE LIVER TOTAL BODY THYROID KIDNEY LUNG GI-LLI H3

0.

2.03E-07 2.03E-07 2.03E-07 2.03E-07 2.03E-07 2.03E-07 BElO 1.35E-05 1.57E-06 3.39E-07

0.

1.llE-06 0.

2.75E-05 C14 1.21E-05 2.42E-06 2.42E-06 2.42E-06 2.42E-06 2.42E-06 2.42E-06 N13 3.lOE-08 3.lOE-08 3.lOE-08 3.lOE-08 3.lOE-08 3.lOE-08 3.lOE-08 F18 2.49E-06 0.

2.47E-07

0.
0.
0.

6.74E-07 NA22 5.BBE-05 5.BBE-05 5.BBE-05 5.BBE-05 5.BBE-05 5.BBE-05 5.BBE-05 NA24 5.BOE-06 5.BOE-06 5.BOE-06 5.BOE-06 5.BOE-06 5.BOE-06 5.BOE-06 P32 8.25E-04 3.86E-05 3.lBE-05

0.
0.
0.

2.28E-05 AR39 0.

0.
0.
0.
0.
0.
0.

AR41

0.
0.
0.
0.
0.
0.
0.

CA41 3.47E-04 0.

3.79E-05

0.
0.
0.

1.90E-07 SC46 1.97E-08 2.70E-08 1.04E-08

0.

2.30E-08 0.

3.95E-05 CR51

0.
0.

8.90E-09 4.94E-09 l.35E-09 9.02E-09 4.72E-07 MN54

0.

1.07E-05 2.85E-06

0.

3.00E-06 0.

8.98E-06 MN56

0.

3.34E-07 7.54E-08

0.

4.04E-07

0.

4.84E-05 FE55 l.15E-05 6.lOE-06 l.89E-06

0.
0.

3.45E-06 l.13E-06 FE59 l.65E-05 2.67E-05 l.33E-05

0.
0.

7.74E-06 2.78E-05 C057

0.

4.93E-07 9.98E-07

0.
0.
0.

4.04E-06 COSS

0.

l.BOE-06 5.51E-06

0.
0.
0.

1.0SE-05 C060

0.

5.29E-06 l.56E-05

0.
0.
0.

2.93E-05

  • NI59 4.02E-05 l.07E-05 6.82E-06
0.
0.
0.

7.lOE-07 NI63 5.38E-04 2.BBE-05 l.83E-05

0.
0.
0.

1.94E-06 NI65 2.22E-06 2.09E-07 l.22E-07

0.
0.
0.

2.56E-05 CU64

0.

2.45E-07 l.48E-07

0.

5.92E-07 0.

1.15E-05 ZN65 l.37E-05 3.65E-05 2.27E-05

0.

2.30E-05 0.

6.41E-06 ZN69M+D 7.lOE-07 1.21E-06 l.43E-07

0.

7.03E-07 0.

3.94E-05 ZN69 4.38E-08 6.33E-08 5.85E-09

0.

3.84E-08 0.

3.99E-06 SE79

0.

8.43E-06 l.87E-06

0.

1.37E-05 0.

5.53E-07 BR82

0.
0.

7.55E-06

0.
0.
0.
0.

BR83+D

0.
0.

l.71E-07

0.
0.
0.
0.

BR84

0.
0.
1. 98E-07
0.
0.
0.
0.

BR85 0

0.

9.12E-09

0.
0.
0.
0.

KR83M 0.

0.

0.

0.

0.

0.

0.

KR85M 0.

0.

0.

0.

0.

0.

0.

KR85 0.

0.

0.

0.

0.

0.

0.

KR87

0.
0.
0.
0.
0.
0.
0.

KR88+D 0.

0.

0.

0.

0.

0.

0.

KR89

0.
0.
0.
0.
0.
0.
0.

RB86

0.

6.70E-05 4.12E-05

0.
0.
0.

4.31E-06 RB87

0.

3.95E-05 l.83E-05

0.
0.
0.

5.92E-07 RB88

0.

1.90E-07 l.32E-07

0.
0.
0.

9.32E-09 RB89+D

0.

l.17E-07 l.04E-07

0.
0.
0.

1.02E-09 SR89+D l.32E-03 0.

3.77E-05

0.
0.
0.

5.llE-05 SR90+D l.70E-02 0.

4.31E-03

0.
0.
0.

2.29E-04 SR9l+D 2.40E-05 0.

9.06E-07

0.
0.
0.

5.30E-05 SR92+D 9.03E-06 0.

3.62E-07

0.
0.
0.

1.71E-04

  • 74

t l

J J

ISOTOPE Y90 Y91M+D Y91 Y92 Y93 ZR93+D ZR95+D ZR97+D NB93M NB95 NB97 M093 M099+D TC99M TC99 TClOl RU103+D RU105+D RU106+D RH105 PD107 PD109 AGllOM+D AGlll CD113M CD115M SN123 SN125+D SN126+D SB124 SB125+D SB126 SB127 TE125M TE127M+D TE127 TE129M+D TE129 TE131M+D TE131+D TE132+D TE133M+D TE134+D Il29 Il30 Il31 +D BONE LIVER TOTAL BODY THYROID-KIDNEY LUNG GI-LLI 4.llE-08 0.

1.lOE-09

0.
0.
0.

1.l?E-04 3.82E-10

0.

1.39E-ll

0.
0.
0.

7.48E-07 6.02E-07

0.

1.61E-08

0.
0.
0.

8.02E-05 3.60E-09 0.

1.03E-10

0.
0.
0.

1.04E-04 1.14E-08 0.

3.13E-10

0.
0.
0.

1.70E-04 l.67E-07 6.25E-08 4.45E-08

0.

2.42E-07 0.

2.37E-05 l.16E-07 2.55E-08 2.27E-08

0.

3.65E-08 0.

2.66E-05 6.99E-09 1.0lE-09 5.96E-10

0.

1.45E-09 0.

1.53E-04 1.05E-07 2.62E-08 8.61E-09

0.

2.83E-08 0.

3.95E-06 2.25E-08 8.76E-09 6.26E-09

0.

8.23E-09 0.

1.62E-05 2.17E-10 3.92E-11 1.83E-11

0.

4.35E-ll 0.

1.21E-05

0.

2.41E-05 8.65E-07

0.

6.35E-06 0.

1.22E-06

0.

1.33E-05 3.29E-06

0.

2.84E-05 0.

1.lOE-05 9.23E-10 1.81E-09 3.00E-08

0.

2.63E-08 9.19E-10 1.03E-06 5.35E-07 5.96E-07 2.14E-07

0.

7.02E-06 5.27E-08 6.25E-06 1.07E-09 1.12E-09 1.42E-08

0.

1.91E-08 5.92E-10 3.56E-09 7.31E-07

0.

2.81E-07

0.

1.84E-06 0.

1.89E-05 6.45E-08

0.

2.34E-08

0.

5.67E-07 0.

4.21E-05 1.17E-05 0.

1.46E-06

0.

1.58E-05 0.

1.82E-04 5.14E-07 2.76E-07 2.36E-07

0.

1.lOE-06 0.

1.71E-05

0.

4.72E-07 4.0lE-08

0.

3.95E-06 0.

9.37E-07

0.

5.67E-07 1.70E-07

0.

3.04E-06 0.

3.35E-05 5.39E-07 3.64E-07 2.91E-07

0.

6.78E-07 0.

4.33E-05 2.48E-07 7.76E-08 5.12E-08

0.

2.34E-07 0.

4.75E-05

0.

1.02E-05 4.34E-07

0.

1.05E-05 0.

2.63E-05

0.

5.89E-06 2.51E-07

0.

4.38E-06 0.

8.0lE-05 1.33E-04 1.65E-06 3.24E-06 1.75E-06 0.

0.

6.52E-05 3.55E-05 5.35E-07 1.59E-06 5.55E-07

0.
0.

1.lOE-04 3.33E-04 4.15E-06 9.46E-06 1.14E-06 0.

0.

2.50E-05 1.llE-05 1.44E-07 3.89E-06 2.45E-08 0.

6.16E-06 6.94E-05 7.16E-06 5.52E-08 1.50E-06 6.63E-09 0.

3.99E-06 1.71E-05 4.40E-06 6.73E-08 1.58E-06 2.58E-08

0.

2.lOE-06 8.87E-05 1.06E-06 1.64E-08 3.68E-07 1.18E-08 0.

4.60E-07 5.97E-05 1.14E-05 3.09E-06 1.52E-06 3.20E-06 0.

0.

1.lOE-05 2.89E-05 7.78E-06 3.43E-06 6.91E-06 8.24E-05 0.

2.34E-05 4.71E-07 1.27E-07 1.0lE-07 3.26E-07 1.34E-06 0.

1.84E-05 4.87E-05 1.36E-05 7.56E-06 1.57E-05 1.43E-04 0.

5.94E-05 1.34E-07 3.74E-08 3.18E-08 9.56E-08 3.92E-07 0.

8.34E-06 7.20E-06 2.49E-06 2.65E-06 5.12E-06 2.41E-05 0.

1.0lE-04 8.30E-08 2.53E-08 2.47E-08 6.35E-08 2.51E-07 0.

4.36E-07 1.0lE-05 4.47E-06 5.40E-06 6.51E-06 4.15E-05 0.

4.50E-05 l.87E-07 7.56E-08 9.37E-08 1.45E-07 7.18E-07 0.

5.77E-06 1.29E-07 5.80E-08 7.74E-08 1.02E-07 5.37E-07 0.

5.89E-07 l.39E-05 8.53E-06 7.62E-06 5.58E-03 1.44E-05 0.

4.29E-07 2.92E-06 5.90E-06 3.04E-06 6.50E-04 8.82E-06 0.

2.76E-06 l.72E-05 1.73E-05 9.83E-06 5.72E-03 2.84E-05 0.

l.54E-06 75

PALISADES NUCLEAR PLANT OFFSITE DOSE CALCULATION MANUAL Revision 9 TABLE 2.1 l

I I

}

  • CHILD INGESTION DOSE COMMITMENT FACTORS CMREM/50Y PER PCI INGESTED IN FIRST YR)

ISOTOPE 1132 1133+0 1134 1135+0 XE131M XE133M XE133 XE135M XE135 XE137 XE138+0 CS134M+O CS134 CS135 CS136 CS137+0 CS138 CS139+0 BA139 BA140+0 BA141+0 BA142+0 LA140 LA141 LA142 CE141 CE143+0 CE144+0 PR143 PR144 N0147+0 PM147 PM148M+O PM148 PM149 PM151 SM151 SM153 EU152 EU154 EU155 EU156 TB160 H0166M Wl81 Wl85 Wl87 BONE LIVER TOTAL BODY THYROID KIDNEY LUNG GI-LLI 8.00E-07 l.47E-06 6.76E-07 6.82E-05 2.25E-06 0.

l.73E-06 5.92E-06 7.32E-06 2.77E-06 l.36E-03 l.22E-05 0.

2.95E-06 4.19E-07 7.78E-07 3.58E-07 l.79E-05 l.19E-06 0.

5.16E-07 l.75E-06 3.15E-06 l.49E-06 2.79E-04 4.83E-06 0.

2.40E-06

0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.

8.44E-08 l.25E-07 8.16E-08

0.

6.59E-08 l.09E-08 l.58E-07 2.34E-04 3.84E-04 8.lOE-05

0.

l.19E-04 4.27E-05 2.07E-06 8.30E-05 5.78E-05 5.93E-06

0.

2.04E-05 6.BlE-06 4.33E-07 2.35E-05 6.46E-05 4.lBE-05

0.

3.44E-05 5.13E-06 2.27E-06 3.27E-04 3.13E-04 4.62E-05

0.

l.02E-04 3.67E-05 l.96E-06 2.28E-07 3.17E-07 2.0lE-07

0.

2.23E-07 2.40E-08 l.46E-07 l.45E-07 l.61E-07 7.74E-08

0.

l.21E-07 l.22E-08 l.45E-ll 4.14E-07 2.21E-10 1.20E-08

0.

l.93E-10 l.30E-10 2.39E-05 8.31E-05 7.28E-08 4.85E-06

0.

2.37E-08 4.34E-08 4.21E-05 2.00E-07 l.12E-10 6.SlE-09

0.

9.69E-11 6.58E-10 l.14E-07 8.74E-08 6.29E-ll 4.88E-09

0.

5.09E-ll 3.70E-ll l.14E-09 l.OlE-08 3.53E-09 l.19E-09

0.
0.
0.

9.84E-05 l.35E-09 3.17E-10 6.88E-ll

0.
0.
0.

7.05E-05 5.24E-10 l.67E-10 5.23E-ll

0.
0.
0.

3.31E-05 3.97E-08 l.98E-08 2.94E-09

0.

8.68E-09 0.

2.47E-05 6.99E-09 3.79E-06 5.49E-10

0.

l.59E-09 0.

5.55E-05 2.0BE-06 6.52E-07 l.llE-07

0.

3.61E-07 0.

l.70E-04 3.93E-08 l.18E-08 1.95E-09

0.

6.39E-09 0.

4.24E-05 l.29E-10 3.99E-11 6.49E-12

0.

2.llE-11 0.

8.59E-08 2.79E-08 2.26E-08 1.75E-09

0.

1.24E-08 0.

3.58E-05 3.lBE-07 2.27E-08 1.22E-08

0.

4.0lE-08 0.

9.19E-06 l.03E-07 2.05E-08 2.05E-08

0.

3.04E-08 0.

5.78E-05 3.02E-08 3.63E-09 2.35E-09

0.

6.17E-09 0.

9.70E-05 6.49E-09 6.90E-10 3.74E-10

0.

1.22E-09 0.

4.71E-05 2.92E-09 3.55E-10 2.31E-10

0.

6.02E-10 0.

4.03E-05 2.56E-07 3.81E-08 1.20E-08

0.

3.94E-08 0.

5.53E-06 3.65E-09 2.27E-09 2.19E-10

0.

6.91E-10 0.

3.02E-05 6.15E-07 l.12E-07 l.33E-07

0.

4.73E-07 0.

l.84E-05 2.30E-06 2.07E-07 1.89E-07

0.

9.09E-07 0.

4.81E-05 4.82E-07 3.47E-08 2.72E-08

0.

l.30E-07 0.

8.69E-05 5.62E-08 3.0lE-08 6.23E-09

0.

1.94E-08 0.

6.83E-05 l.66E-07 0.

2.06E-08

0.

4.94E-08 0.

3.68E-05 l.OSE-06 2.26E-07 l.91E-07

0.

3.22E-07 0.

0.

4.23E-06 l.04E-08 1.43E-09

0.
0.
0.

3.79E-07 l.73E-06 4.32E-07 6.0SE-08

0.
0.
0.

l.61E-05 4.29E-07 2.54E-07 l.14E-07

0.
0.
0.

3.57E-05 76

PALISADES NUCLEAR PLANT

(

I I

J OFFSITE DOSE CALCULATION MANUAL Revision 9 TABLE 2.1 CHILD INGESTION DOSE COMMITMENT FACTORS CMREM/50Y PER PC! INGESTED IN FIRST YR)

ISOTOPE BONE LIVER TOTAL BODY THYROID KIDNEY LUNG GI* LU PB210+0 4.75E-02 l.22E-02 2.09E-03

0.

3.67E-02 0.

5.57E-05 BI210+0 l.97E-06 l.02E-05

1. 69E-07
0.

l.15E-04 0.

5.17E-05 P0210 1.52E-03 2.43E-03 3.67E-04

0.

7.56E-03 0.

6.55E-05 RN222+0

0.
0.
0.
0.
0.
0.
0.

RA223+0 2.12E-02 2.45E-05 4.24E-03

0.

6.50E-04 0.

3.38E-04 RA224+0 6.89E-03 l.25E-05 l.38E-03

0.

3.31E-04 0.

3.78E-04 RA225+0 2.BOE-02 2.50E-05 5.59E-03

0.

6.62E-04 0.

3.21E-04 RA226+0 5.75E-Ol

1. 84E-05 4.72E-Ol
0.

4.BBE-04 0.

3.41E-04 RA228+0 3.85E-01 9.99E-06 4.32E-01

0.

2.65E-04 0.

5.BlE-05 AC225 l.BSE-05 1.94E-05

1. 26E-06
0.

2.07E-06 0.

4.31E-04 AC227+0 4.12E-03 6.63E-04 2.55E-04

0.
1. 46E-04 0.

8.43E-05 TH227+0 5.85E-05 7.96E-07 l.69E-06

0.

4.22E-06 0.

5.63E-04 TH228+0 2.07E-03 2.65E-05 7.00E-05

0.

l.38E-04 0.

5.79E-04 TH229 l.38E-02 l.SlE-04 6.BOE-04

0.

8.84E-04 0.

5.27E-04 TH230 3.55E-03 1. 78E-04 9.91E-05

0.

8.67E-04 0.

6.19E-05 TH232+0 3.96E-03 1. 52E-04 3.0lE-04

0.

7.41E-04 0.

5.27E-05 TH234 3.42E-07 l.51E-08 9.88E-09

0.

8.0lE-08 0.

l.18E-04 PA231+0 7.07E-03 2.34E-04 2.81E-04

0.

l.28E-03 0.

7.37E-05 PA233 l.81E-08 2.82E-09 3.16E-09

0.
1. 04E-08 0.

l.44E-05 U232+0

1. 76E-02
0.

l.26E-03

0.

l.34E-03 0.

6.98E-05 U233+0 3.72E-03 0.

2.25E-04

0.

6.lOE-04 0.

6.45E-05 U234 3.57E-03 0.

2.21E-04

0.

5.98E-04 0.

6.32E-05 U235+0 3.42E-03 0.

2.07E-04

0.

5.61E-04 0.

8.03E-05 U236 3.42E-03 0.

2.12E-04

0.

5.73E-04 0.

5.92E-05 U237 2.36E-07

0.

6.27E-08

0.

6.81E-07 0.

2.08E-05 U238+0 3.27E-03 0.

1. 94E-04
0.

5.24E-04 0.

5.66E-05 NP237+0 2.36E-03 l.81E-04 9.79E-05

0.

6.05E-04 0.

8.16E-05 NP238 5.83E-08 l.18E-09 9.08E-10

0.

3.76E-09 0.

4.04E-05 NP239 5.25E-09 3. 77E-10 2.65E-10

0.
1. 09E-09 0.

2.79E-05 PU238 1.25E-03 1. 56E-04 3.16E-05

0.

1.15E-04 0.

7.SOE-05 PU239 1.36E-03 1.65E-04 3.31E-05

0.
1. 22E-04 0.

6.85E-05 PU240

1. 36E-03 1. 65E-04 3.31E-05
0.

l.22E-04 0.

6.98E-05 PU241+0 4.00E-05 1. 72E-06 8.04E-07

0.

2.96E-06 0.

1.44E-06 PU242 l.26E-03 1. 59E-04 3.19E-05

0.

1.17E-04 0.

6.71E-05 PU244 1.47E-03 l.82E-04 3.65E-05

0.
1. 35E-04 0.

1.00E-04 AM241

1. 43E-03 6.40E-04 1.02E-04
0.

6.23E-04 0.

7.64E-05 AM242M

1. 47E-03 6.25E-04
1. 04E-04
0.

6.30E-04 0.

9.61E-05 AM243 1.41E-03 6.14E-04 9.83E-05

0.

6.06E-04 0.

8.95E-05 CM242 8.80E-05 6.73E-05 5.84E-06

0.

1.87E-05 0.

8.16E-05 CM243

1. 33E-03 6.03E-04 8.24E-05
0.

3.08E-04 0.

8.03E-05 CM244 1.llE-03 5.36E-04 6.93E-05

0.

2.54E-04 0.

7.77E-05 CM245 1.76E-03 6.64E-04 1.0SE-04

0.
4. llE-04 0.

7.24E-05 CM246

1. 74E-03 6.64E-04
1. OSE-04
0.

4.lOE-04 0..

7.llE-05 CM247+0 l.70E-03 6.53E-04

1. 03E-04
0.

4.04E-04 0.

9.35E-05 CM248 1.41E-02 5.38E-03 8.52E-04 0.

3.33E-03 0.

1. SlE-03 CF252 1.07E-03 0.

2.54E-05

0.
0.
0.

2.96E-04 77

PALISADES NUCLEAR PLANT OFFSITE DOSE CALCULATION MANUAL Revision 9 TABLE 2.1 I

I

)

  • TEEN INGESTION DOSE COMMITMENT FACTORS (MREM/50Y PER PCI INGESTED IN FIRST YR)

ISOTOPE H3 BElO Cl4 N13 F18 NA22 NA24 P32 AR39 AR41 CA41 SC46 CR51 MN54 MN56 FE55 FE59 C057 C058 C060 NI59 NI63 NI65 CU64

  • ZN65 ZN69M+D ZN69 SE79 BR82 BR83+0 BR84 BR85 KR83M KR85M KR85 KR87 KR88+0 KR89 RB86 RB87 RB88 RB89+D SR89+D SR90+D SR9l+D SR92+D BONE LIVER TOTAL BODY THYROID KIDNEY LUNG GI*LLI
0.

1.06E-07 1.06E-07 l.06E-07 1.06E-07 1.06E-07 1.06E-07 4.48E-06 6.94E-07 1.13E-07

0.

5.30E-07 0.

2.84E-05 4.06E-06 8.12E-07 8.12E-07 8.12E-07 8.12E-07 8.12E-07 8.12E-07 1.15E-08 1.15E-08 1.15E-08 l.15E-08 1.15E-08 l.15E-08 1.15E-08 8.64E-07 0.

9.47E-08

0.
0.
0.

7.78E-08 2.34E-05 2.34E-05 2.34E-05 2.34E-05 2.34E-05 2.34E-05 2.34E-05 2.30E-06 2.30E-06 2.30E-06 2.30E-06 2.30E-06 2.30E-06 2.30E-06 2.76E-04 1.71E-05 1.07E-05

0.
0.
0.

2.32E-05

0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.

1.97E-04 0.

2.13E-05

0.
0.
0.

1.95E-07 7.24E-09 1.41E-08 4.18E-09

0.

1.35E-08 0.

4.80E-05

0.
0.

3.60E-09 2.00E-09 7.89E-10 5.14E-09 6.05E-07

0.

5.90E-06 1.17E-06

0.

1.76E-06 0.

1.21E-05

0.

1.58E-07 2.81E-08

0.

2.00E-07

0.

1.04E-05 3.78E-06 2.68E-06 6.25E-07

0.
0.

1.70E-06 1.16E-06 5.87E-06 1.37E-05 5.29E-06

0.
0.

4.32E-06 3.24E-05

0.

2.38E-07 3.99E-07

0.
0.
0.

4.44E-06

0.

9.72E-07 2.24E-06

0.
0.
0.

1.34E-05 0

2.81E-06 6.33E-06

0.
0.
0.

3.66E-05 1.32E-05 4.66E-06 2.24E-06

0.
0.
0.

7.31E-07 1.77E-04 1.25E-05 6.00E-06

0.
0.
0.

1.99E-06 7.49E-07 9.57E-08 4.36E-08

0.
0.
0.

5.193-06

0.

1.15E-07 5.41E-08

0.

2.91E-07 0.

8.92E-06 5.76E-06 2.00E-05 9.33E-06

0.

1.28E-05 0.

8.47E-06 2.40E-07 5.66E-07 5.19E-08

0.

3.44E-07 0.

3.llE-05 1.47E-08 2.80E-08 1.96E-09

0.

1.83E-08 0.

5.16E-08

0.

3.73E-06 6.27E-07

0.

6.50E-06 0.

5.70E-07

0.
0.

3.04E-06

0.
0.
0.
0.
0.
0.
5. 7 4E-08
0.
0.
0.
0.
0.
0.

7.22E-08

0.
0.
0.
0.
0.
0.

3.0SE-09

0.
0.
  • 0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.

2.98E-05 1.40E-05

0.
0.
0.

4.41E-06

0.

1.75E-05 6.llE-06

0.
0.
0.

6.llE-07

0.

8.52E-08 4.54E-08

0.
0.
0.

7.30E-15

0.

5.50E-08 3.89E-08

0.
0.
0.

8.43E-17 4.40E-04 0.

1.26E-05

0.
0.
0.

5.24E-05 8.30E-03 0.

2.05E-03

0.
0.
0.

2.33E-04 8.07E-06 0.

3.21E-07

0.
0.
0.

3.66E-05 3.0SE-06

0.

1.30E-07

0.
0.
0.

7.77E-05 7P

(

l I

J PALISADES NUCLEAR PLANT OFFSITE DOSE CALCULATION MANUAL Revision 9 TABLE 2.1 TEEN INGESTION DOSE COMMITMENT FACTORS CMREM/50Y PER PCI INGESTED IN FIRST YR)

ISOTOPE BONE LIVER TOTAL BODY THYROID KIDNEY LUNG GI*LLI Y90 l.37E-08 0.

3.69E-10

0.
0.
0.

l.13E-04 Y91M+D l.29E-10 0.

4.93E-12

0.
0.
0.

6.09E-09 Y91 2.0lE-07 0.

5.39E-09

0.
0.
0.

8.24E-05 Y92 l.21E-09 0.

3.50E-ll

0.
0.
0.

3.32E-05 Y93 3.83E-09 0.

l.05E-10

0.
0.
0.

l.17E-04 ZR93+D 5.53E-08 2.73E-08 l.49E-08

0.

9.65E-08 0.

2.58E-05 ZR95+D 4.12E-08 l.30E-08 8.94E-09

0.

l.91E-08 0.

3.00E-05 ZR97+D 2.37E-09 4.69E-10 2.16E-10

0.

7.llE-10 0.

l.27E-04 NB93M 3.44E-08 l.13E-08 2.83E-09

0.

l.32E-08 0.

4.07E-06 NB95 8.22E-09 4.56E-09 2.51E-09

0.

4.42E-09 0.

l.95E-05 NB97 7.37E-ll l.83E-ll 6.68E-12

0.

2.14E-ll 0.

4.37E-07 M093

0.

l.06E-05 2.90E-07

0.

3.04E-06 0.

l.29E-06 M099+D

0.

6.03E-06 l.15E-06

0.

l.38E-05 0.

l.OBE-05 TC99M 3.32E-10 9.26E-10 l.20E-08

0.

l.38E-08 5.14E-10 6.08E-07 TC99 l.79E-07 2.63E-07 7.17E-08

0.

3.34E-06 2.72E-08 6.44E-06 TClOl 3.60E-10 5.12E-10 5.03E-09

0.

9.26E-09 3.12E-10 8.75E-17 RU103+D 2.55E-07 0.

l.09E-07

0.

8.99E-07 0.

2.13E-05 RU105+D 2.18E-08 0.

8.46E-09

0.

2.75E-07 0.

l.76E-05 RU106+D 3.92E-06 0.

4.94E-07

0.

7.56E-06 0.

l.88E-04 RH105 l.73E-07 l.25E-07 8.20E-08

0.

5.31E-07 0.

l.59E-05 PD107

0.

2.08E-07 l.34E-08

0.

l.88E-06 0.

9.66E-07 PD109

0.

2.51E-07 5.70E-08

0.

l.45E-06 0.

2.53E-05 AGllOM+D 2.05E-07 l.94E-07 l.18E-07

0.

3.70E-07 0.

5.45E-05 AGlll 8.29E-08 3.44E-08 l.73E-08

0.

l.12E-07 0.

4.80E-05 CD113M

0.

4.51E-06 l.45E-07

0.

4.99E-06 0.

2.71E-05 CD115M

0.

2.60E-06 8.39E-08

0.

2.0BE-06 0.

8.23E-05 SN123 4.44E-05 7.29E-07 l.08E-Q6 5.84E-07 0.

0.

6.71E-05 SN125+D l.19E-05 2.37E-07 5.37E-07 l.86E-07 0.

0.

l.12E-04 SN126+D l.16E-04 2.16E-06 3.30E-06 5.69E-07 0.

0.

2.58E-05 SB124 3.87E-06 7.13E-08 l.51E-06 8.78E-09 0.

3.38E-06 7.80E-05 SB125+D 2.48E-06 2.71E-08 5.80E-07 2.37E-09 0.

2.18E-06 l.93E-05 SB126 l.59E-06 3.25E-08 5.71E-07 8.99E-09 0.

1.14E-06 9.41E-05 SB127 3.63E-07 7.76E-09 1.37E-07 4.0BE-09 0.

2.47E-07 6.16E-05 TE125M 3.83E-06 1.38E-06 5.12E-07 l.O?E-06 0.

0.

1.13E-05 TE127M+D 9.67E-06 3.43E-06 1.15E-06 2.30E-06 3.92E-05 0.

2.41E-05 TE127 l.58E-07 5.60E-08 3.40E-08

.l.09E-07 6.40E-07 0.

l.22E-05 TE129M+D l.63E-05 6.05E-06 2.58E-06 5.26E-06 6.82E-05 0.

6.12E-05 TE129 4.48E-08 l.67E-08 1.09E-08 3.20E-08 l.88E-07 0.

2.45E-07 TE131M+D 2.44E-06 l.17E-06 9.76E-07 l.76E-06 l.22E-05 0.

9.39E-05 TE13l+D 2.79E-08 l.15E-08 8.72E-09 2.15E-08 l.22E-07 0.

2.29E-09 TE132+D 3.49E-06 2.21E-06 2.0BE-06 2.33E-06 2.12E-05 0.

7.00E-05 TE133M+D 6.44E-08 3.66E-08 3.56E-08 5.llE-08 3.62E-07 0.

l.48E-07 TE134+D 4.47E-08 2.87E-08 3.00E-08 3.67E-08 2.74E-07 0.

l.66E-09 1129 4.66E-06 3.92E-06 6.54E-06 4.77E-03 7.0lE-06 0.

4.57E-07 1130 l.03E-06 2.98E-06 l.19E-06 2.43E-04 4.59E-06 0.

2.29E-06 1131+0 5.85E-06 8.19E-06 4.40E-06 2.39E-03 l.41E-05 0.

l.62E-06 79

PALISADES NUCLEAR PLANT OFFSITE DOSE CALCULATION MANUAL Revision 9 TABLE 2.1 TEEN INGESTION DOSE COMMITMENT FACTORS CMREM/SOY PER PCI INGESTED IN FIRST YR)

ISOTOPE Il32 Il33+D I134 I135+D XE131M XE133M XE133 XE135M XE135 XE137 XE138+D CS134M+D CS134 CS135 CS136 CS137+D CS138 CS139+D BA139 BA140+D BA14l+D BA142+D LA140 LA141 LA142 CE141 CE143+D CE144+D PR143 PR144 ND147+D PM147 PM148M+D PM148 PM149 PM151 SM151 SM153 EU152 EU154 EU155 EU156 TB160 H0166M W181 Wl85 Wl87 BONE LIVER TOTAL BODY THYROID KIDNEY LUNG GI-LLI 2.79E-07 7.30E-07 2.62E-07 2.46E-05 1.lSE-06 0.

3.18E-07 2.0lE-06 3.41E-06 1.04E-06 4.76E-04 5.98E-06 0.

2.58E-06 1.46E-07 3.87E-07 1.39E-07 6.45E-06 6.lOE-07 0.

5.lOE-09 6.lOE-07 1.57E-06 5.82E-07 1.0lE-04 2.48E-06 0.

1.74E-06

0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.

2.94E-08 6.09E-08 3.13E-08

0.

3.39E-08 5.95E-09 4.0SE-08 8.37E-05 1.97E-04 9.14E-05

0.

6.26E-05 2.39E-05 2.45E-06 2.78E-05 2.55E-05 5.96E-06

0.

9.73E-06 3.52E-06 4.46E-07 8.59E-06' 3.38E-05 2.27E-05

0.

1.84E-05 2.90E-06 2.72E-06 l.12E-04 1.49E-04 5.19E-05

0.

5.07E-05 1.97E-05 2.12E-06 7.76E-08 1.49E-07 7.45E-08

0.

1.lOE-07 l.28E-08 6.76E-11 4.87E-08 7.17E-08 2.63E-08

0.

5.79E-08 6.34E-09 3.33E-23 1.39E-07 9.78E-11 4.05E-09

0.

9.22E-11 6.74E-11 1.24E-06 2.84E-05 3.48E-08 1.83E-06

0.

1.18E-08 2.34E-08 4.38E-05 6.71E-08 5.0lE-11 2.24E-09

0.

4.65E-11 3.43E-11 1.43E-13 2.99E-08 2.99E-11 1.84E-09

0.

2.53E-11 1.99E-11 9.18E-20 3.48E-09 1.71E-09 4.SSE-10

0.
0.
0.

9.82E-05 4.55E-10 1.40E-10 2.31E-11

0.
0.
0.

2.48E-05 1.79E-10 7.95E-11 1.98E-11

0.
0.
0.

2.42E-06 1.33E-08 8.88E-09 1.02E-09. 0.

4.18E-09 0.

2.54E-05 2.35E-09 1.71E-06 1.91E-10

0.

7.67E-10 0.

5.14E-05 6.96E-07 2.88E-07 3.74E-08

0.

1.72E-07 0.

1.75E-04 l.31E-08 5.23E-09 6.52E-10

0.

3.04E-09 0.

4.31E-05 4.30E-11 1.76E-11 2.18E-12

0.

1.0lE-11 0.

4.74E-14 9.38E-09 1.02E-08 6.llE-10

0.

5.99E-09 0.

3.68E-05 1.05E-07 9.96E-09 4.06E-09

0.

1.90E-08 0.

9.47E-06 4.14E-08 1.05E-08 8.21E-09

0.

1.59E-08 0.

6.61E-05 l.02E-08 l.66E-09 8.36E-10

0.

3.00E-09 0.

9.90E-05 2.17E-09 3.05E-10 l.25E-10

0.

5.81E-10 0.

4.49E-05 9.87E-10 l.63E-10 8.25E-11

0.

2.93E-10 0.

3.66E-05 8.73E-08 1.68E-08 3.94E-09

0.

l.84E-08 0.

5.70E-06 l.22E-09 l.OlE-09 7.43E-ll

0.

3.30E-10 0.

2.85E-05 2.45E-07 5.90E-08 5.20E-08

0.

2.74E-07 0.

2.17E-05 7.91E-07 l.02E-07 7.19E-08

0.

4.56E-07

0.

5.39E-05 1.74E-07 l.68E-08 l.04E-08

0.

6.57E-08 0.

9.63E-05 l.92E-08 l.44E-08 2.35E-09

0.

9.69E-09 0.

7.36E-05 6.47E-08 0.

8.07E-09

0.

2.56E-08 0.

4.19E-05 3.57E-07 l.lOE-07 7.96E-08

0.

l.61E-07 0.

0.

l.42E-08 4.58E-09 4.79E-10

0.
0.
0.

3.90E-07 5.79E-07 l.91E-07 2.02E-08

0.
0.
0.

1.65E-05 l.46E-07 l.19E-07 4.17E-08

0.
0.
0.

3.22E-05 80

(. '

.J PALISADES NUCLEAR PLANT OFFSITE DOSE CALCULATION MANUAL Revision 9 TABLE 2.1 TEEN INGESTION DOSE COMMITMENT FACTORS (MREM/50Y PER PCI INGESTED IN FIRST YR)

ISOTOPE BONE LIVER TOTAL BODY THYROID KIDNEY LUNG GI* LLI PB210+0

1. SlE-02 5.44E-03 7.0lE-04
0.
1. 72E-02
0.

5.74E-05 81210+0 6.59E-07 4.51E-06 5.66E-08

0.

5.48E-05 0.

5.15E-05 P0210 6.09E-04 l.07E-03 l.23E-04

0.

3.60E-03 0.

6.75E-05 RN222+0

0.
0.
0.
0.
0.
0.
0.

RA223+0

7. llE-03 l.OSE-05 l.42E-03
0.

3.lOE-04 0.

3.43E-04 RA224+0 2.31E-03 5.52E-06 4.61E-04

0.
1. 58E-04 0.
3. 71E-04 RA225+0 9.37E-03 l. lOE-05 l.87E-03
0.

3.15E-04 0.

3.27E-04 RA226+0 3.22E-Ol 8.13E-06 2.39E-Ol

0.

2.32E-04 0.

3.51E-04 RA228+0

1. 37E-Ol 4.41E-06 l.51E-Ol
0.

l.26E-04 0.

5.98E-05 AC225 6.29E-06 8.59E-06 4.22E-07

0.

9.85E-07

0.

4.36E-04 AC227+0 2.05E-03 3.03E-04 l.22E-04

0.

8.SlE-05 0.

8.68E-05 TH227+0 l.96E-05 3.52E-07 5.65E-07

0.

2.0lE-06 0.

5.75E-04 TH228+0 6.SOE-04 l.14E-05 2.30E-05

0.

6.41E-05 0.

5.97E-04 TH229 8.39E-03 1.26E-04

4. llE-04
0.
6. lOE-04 0.

5.43E-04 TH230 2.16E-03 l.23E-04 6.00E-05

0.

5.99E-04 0.

6.38E-05 TH232+0 2.42E-03 l.OSE-04 1.63E-04

0.
5. llE-04 0.

5.43E-05 TH234 1.14E-07 6.68E-09 3.31E-09

0.

3.BlE-08 0.

1.21E-04 PA231+0 4.31E-03 1. 62E-04 L 68E-04

0.

9.lOE-04 0.

7.60E-05 PA233 7.33E-09 1.41E-09 1.26E-09

0.

5.32E-09 0.

1.61E-05 U232+0 5.89E-03 0.

4.21E-04

0.

6.38E-04 0.

7.19E-05 U233+0 1.24E-03 0.

7.543-05

0.

2.90E-04 0.

6.65E-05 U234 l.19E-03 0.

7.39E-05

0.

2.85E-04 0.

6.51E-05 U235+D l.14E-03 0.

6.94E-05

0.

2.67E-04 0.

8.28E-05 U236 l.14E-03 0.

7.09E-05

0.

2.73E-04 0.

6.llE-05 U237 7.89E-08 0.

2.lOE-08

0.

3.24E-07 0.

2.09E-05 U238+D

1. 09E-03 0.

6.49E-05

0.

2.50E-04 0.

5.83E-05 NP237+0 1.44E-03 1.25E-04 5.85E-05

0.

4.33E-04 0.

8.41E-05 NP238

1. 95E-08 5.22E-10 3.04E-10
0.

1.79E-09 0.

3.83E-05 NP239

1. 76E-09 1. 66E-10 9.22E-ll
0.

5.21E-10 0.

2.67E-05 PU238 7.21E-04 1.02E-04 1.82E-05

0.

7.80E-05 0.

7.73E-05 PU239 8.27E-04 1.12E-04 2.0lE-05

0.

8.57E-05 0.

7.06E-05 PU240 8.26E-04 l.12E-04 2.0lE-05

0.

8.56E-05 0.

7.19E-05 PU241+0

1. 84E 9.42E-07 3.69E-07
0.

l.71E-06 0.

1.48E-06 PU242 7.66E-04 1. OBE-04 1.94E-05

0.

8.25E-05 0.

6.92E-05 PU244 8.95E-04 1. 23E-04 2.22E-05

0.

9.45E-05 0.

1.03E-04 AM241 8.62E-04 -3.29E-04 5.75E-05

0.

4.31E-04 0.

7.87E-05 AM242M 8.70E-04 3.19E-04 5.80E-05

0.

4.30E-04 0.

9.90E-05 AM243 8.60E-04 3.17E-04 5.62E-05

0.

4.22E-04 0.

9.23E-05 CM242 2.94E-05 2.97E-05 1.95E-06

0.

8.89E-06 0.

8.40E-05 CM243 6.91E-04 2.86E-04 4.09E-05

0.
1. 91E-04 0.

8.28E-05 CM244 5.32E-04 2.49E-04 3.19E-05

0.

1.49E-04 0.

8.00E-05 CM245 1.07E-03 3.33E-04 6.lOE-05

0.

2.85E-04 0.

7.46E-05 CM246

1. 06E-03 3.32E-04 6.09E-05
0.

2.84E-04 0.

7.33E-05 CM247+0 1.03E-03 3.27E-04 6.00E-05

0.

2.BOE-04 0.

9.63E-05 CM248 8.60E-03 2.69E-03 4.95E-04

0.

2.31E-03 0.

1.55E-03 CR252 3.51E-04 0.

8.37E-06

0.
0.
0.

3.05E-04 81

PALISADES NUCLEAR PLANT OFFSITE DOSE CALCULATION MANUAL Revision 9 TABLE 2.1

(

I I

)

  • ADULT INGESTION DOSE COMMITMENT FACTORS (MREM/50Y PER PCI INGESTED IN FIRST YR)

ISOTOPE H3 BElO C14 N13 Fl8 NA22 NA24 P32 AR39 AR41 CA41 SC46 CR51 MN54 MN56 FE55 FE59 C057 C058 C060 NI59 NI63 NI65 CU64 ZN65 ZN69M+D ZN69 SE79 BR82 BR83+D BR84 BR85 KR83M KR85M KR85 KR87 KR88+D KR89 RB86 RB87 RB88 RB89+D SR89+D SR90+D SR9l+D SR92+D BONE LIVER TOTAL BODY THYROID KIDNEY LUNG GI-LLI

0.

1.0SE-07 1.0SE-07 1.05E-07 1.0SE-07 1.0SE-07 1.05E-07 3.18E-06 4.91E-07 7.94E-08

0.

3.71E-07

0.

2.68E-05 2.84E-06 5.68E-07 5.68E-07 5.68E-07 5.68E-07 5.68E-07 5.68E-07 8.36E-09 8.36E-09 8.36E-09 8.36E-09 8.36E-09 8.36E-09 8.36E-09 6.24E-07

0.

6.92E-08

0.
0.
0.

l.85E-08 1.74E-05 l.74E-05 1.74E-05 1.74E-05 l.74E-05 1.74E-05 1.74E-05 1.70E-06 1.70E-06 l.70E-06 1.70E-06 1.70E-06 1.70E-06 1.70E-06 1.93E-04 l.20E-05 7.46E-06

0.
0.
0.

2.17E-05

0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.

1.83E-05 0.

2.00E-05

0.
0.
0.

l.84E-07 5.51E-09 1.07E-08 3.llE-09

0.

9.99E-09 0.

5.21E-05

0.
0.

2.66E-09 1.59E-09 5.86E-10 3.53E-09 6.69E-07

0.

4.57E-06 8.72E-07

0.

1.36E-06 0.

1.40E-05

0.

l.lSE-07 2.04E-08

0.

1.46E-07 0.

3.67E-06 2.75E-06 1.90E-06 4.43E-07

0.
0.

1.06E-06 1.09E-06 4.34E-06 1.02E-05 3.91E-06

0.
0.

2.85E-06 3.40E-05

0.

1.75E-07 2.91E-07

0.
0.
0.

4.44E-06

0.
7. 45E-07
1. 67E-06
0..
0.
0.
1. 51E-05

_..1

0.

2.14E-06 4.72E-06

0.
0.
0.

4.02E-05 9.76E-06 3.35E-06 1.63E-06

0.
0.
0.

6.90E-07 1.30E-04 9.0lE-06 4.36E-06

0.
0.
0.

1.88E-06 5.28E-07 6.86E-08 3.13E-08

0.
0.
0.

1.74E-06

0.

8.33E-08 3.91E-08

0.

2.lOE-07 0.

7.lOE-06 4.84E-06 1.54E-05 6.96E-06

0.

1.03E-05 0.

9.70E-06 1.70E-07 4.08E-07 3.73E-08

0.

2.47E-07 0.

2.49E-05 1.03E-08 l.97E-08 1.37E-09

0.

l.28E-08 0.

2.96E-09

0.

2.63E-06 4.39E-07

0.

4.55E-06 0.

5.38E-07

0.
0.

2.26E-06

0.
0.
0.

2.59E-06

0.
0.

4.02E-08

0.
0.
0.

5.79E-08

0.
0.

5.21E-08

0.
0.
0.

4.09E-13

0.
0.

2.14E-09

0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.

2.llE-05 9.83E-06

0.
0.
0.

4.16E-06

0.

1.23E-05 4:28E-06

0.
0.
0.

5.76E-07

0.

6.0SE-08 3.21E-08

0.
0.
0.

8.36E-19

0.

4.0lE-08 2.82E-08

0.
0.
0.

2.33E-21 3.0BE-04 0.

8.84E-06

0.
0.
0.

4.94E-05 7.58E-03 0.

l.86E-03

0.
0.
0.

2.19E-04 5.67E-06 0.

2.29E-07

0.
0.
0.

2.70E-05 2.15E-06 0.

9.30E-08

0.
0.
0.

4.26E-05 82

(

I

)

PALISADES NUCLEAR PLANT OFFSITE DOSE CALCULATION MANUAL Revision 9 TABLE 2.1 ADULT INGESTION DOSE COMMITMENT FACTORS CMREM/50Y PER PCI INGESTED IN FIRST YR)

ISOTOPE BONE LIVER TOTAL BODY THYROID KIDNEY LUNG GI-LLI Y90 9.62E-09 0.

2.58E-10

0.
0.
0.

l.02E-04 Y91M+D 9.09E-ll 0.

3.52E-12

0.
0.
0.

2.67E-10 Y91 l.41E-07

0.

3.77E-09

0.
0.
0.

7.76E-05 Y92 8.45E-10

0.

2.47E-ll

0.
0.
0.

l.48E-05 Y93 2.68E-09 0.

7.40E-ll

0.
0.
0.

8.50E-05 ZR93+0 4.18E-08 2.34E-09 l.09E-09

0.

8.87E-09* 0.

2.43E-06 ZR95+0 3.04E-08 9.75E-09 6.60E-09

0.

l.53E-08 0.

3.09E-05 ZR97+0 l.68E-09 3.39E-10 l.55E-10

0.

5.12E-10 0.

l.05E-04 NB93M

  • 2.55E-08 8.32E-09 2.05E-09
0.

9.57E-09 0.

3.84E-06 NB95 6.22E-09 3.46E-09 l.86E-09

0.

3.42E-09 0.

2.lOE-05 NB97 5.22E-ll l.32E-ll 4.82E-12

0.

l.54E-ll 0.

4.87E-08 M093

0.

7.51E-06 2.03E-07

0.

2.13E-06 0.

l.22E-06 M099+0

0.

4.31E-06 8.20E-07

0.

9.76E-06 0.

9.99E-06 TC99M 2.47E-10 6.98E-10 8.89E-09

0.

l.06E-08 3.42E-10 4.13E-07 TC99 l.25E-07 l.86E-07 5.02E-08

0.

2.34E-06 l.58E-08 6.08E-06 TClOl 2.54E-10 3.66E-10 3.59E-09

0.

6.59E-09 l.87E-10 l.lOE-21 RU103+0 l.85E-07

0.

7.97E-08

0.

7.06E-07 0.

2.16E-05 RU105+0 l.54E-08 0.

6.08E-09

0.

l.99E-07 0.

9.42E-06 RU106+0 2.75E-06

0.

3.48E-07

0.

5.31E-06 0.

l.78E-04 RH105 l.21E-07 8.85E-08 5.83E-08

0.

3.76E-07 0.

l.41E-05 PD107

0.

1.47E-07 9.40E-09

0.

1.32E-06 0.

9.llE-07 PD109

0.

l.77E-07 3.99E-08

0.

1.0lE-06 0.

l.96E-05 AGllOM+D l.60E-07 l.48E-07 8.79E-08

0.

2.91E-07 0.

6.04E-05 AGlll 5.81E-08 2.43E-08 1.21E-08

0.

7.84E-08 0.

4.46E-05 CD113M

0.

3.18E-06 l.02E-07

0.

3.50E-06 0.

2.56E-05 CD115M

0.

1.84E-06 5.87E-08

0.

l.46E-06 0.

7.74E-05 SN123 3.llE-05 5.15E-07 7.59E-07 4.38E-07 0.

0.

6.33E-05 SN125+D 8.33E-06 1.68E-07 3.78E-07 l.39E-07 0.

0.

l.04E-04 SN126+D 8.45E-05 1.67E-06 2.40E-06 4.92E-07 0.

0.

2.43E-05 SB124 2.BOE-06 5.29E-08 1.llE-06 6.79E-09 0.

2.18E-06 7.95E-05 SB125+0 1.79E-06 2.00E-08 4.26E-07 l.82E-09 0.

1.38E-06 l.97E-05 SB126 l.15E-06 2.34E-08 4.15E-07 7.04E-09 0.

7.05E-07 9.40E-05 SB127 2.58E-07 5.65E-09 9.90E-08 3.lOE-09 0.

1.53E-07 5.90E-05 TE125M 2.68E-06 9.71E-07 3.59E-07 8.06E-07 l.09E-05 0.

l.07E-05 TE125M+D 6.77E-06 2.42E-06* 8.25E-07 l.73E-06 2.75E-05 0.

2.27E-05 TE127 l.lOE-07 3.95E-08 2.38E-08 8.15E-08 4.48E-07 0.

8.68E-06 TE129M+D l.15E-05 4.29E-06 l.82E-06 3.95E-06 4.BOE-05 0.

5.79E-05 TE129 3.14E-08 1.lBE-08 7.65E-09 2.41E-08 1.32E-07 0.

2.37E-08 TE131M+D l.73E-06 8.46E-07 7.05E-07 l.34E-06 8.57E-06 0.

8.40E-05 TE131+0 l.97E-08 8.23E-09 6.22E-09 l.62E-08 8.63E-08 0.

2.79E-09 TE132+D 2.52E-06 l.63E-06 l.53E-06 l.80E-06 l.57E-05 0.

7.71E-05 TE133M+D 4.62E-08 2.70E-08 2.60E-08 3.91E-08 2.67E-07 0.

6.64E-08 TE134+0 3.24E-08 2.12E-08 l.30E-08 2.83E-08 2.05E-07 0.

3.59E-ll 1129 3.27E-06 2.81E-06 9.21E-06 7.23E-03 6.04E-06 0.

4.44E-07 1130 7.56E-07 2.23E-06 8.BOE-07 l.89E-04 3.48E-06 0.

l.92E-06 1131+0 4.16E-06 5.95E-06 3.41E-06 l.95E-03 1.02E-05 0.

l.57E-06 83

PALISADES NUCLEAR PLANT OFFSITE DOSE CALCULATION MANUAL Revision 9 TABLE 2.1

(

I ADULT INGESTION DOSE COMMITMENT FACTORS (MREM/50Y PER PCI INGESTED IN FIRST YR)

ISOTOPE 1132 1133+0 1134 1135+0 XE131M XE133M XE133 XE135M XE135 XE137 XE138+0 CS134M+O CS134 CS135 CS136 CS137+0 CS138 CS139+0 BA139 BA140+0 BA141+0 BA142+0 LA140 LA141 LA142 CE141 CE143+0 CE144+0 PR143 PR144 N0147+0 PM147 PM148M+O PM148 PM149 PM151 SM151 SM153 EU152 EU154 EU155 EU156 TB160 H0166M Wl81 Wl85 Wl87 BONE LIVER TOTAL BODY THYROID KIDNEY LUNG GI-LLI 2.03E-07 5.43E-07 l.90E-07 l.90E-05 8.65E-07 0.

l.02E-07 l.42E-06 2.47E-06 7.53E-07 3.63E-04 4.31E-06 0.

2.22E-06 l.06E-07 2.88E-07 l.03E-07 4.99E-06 4.58E-07 0.

2.51E-10 4.43E-07 l.16E-06 4.28E-07 7.65E-05 l.86E-06 0.

l.31E-06

0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.

2.13E-08 4.48E-08 2.29E-08

0.

2.43E-08 3.83E-09 1.58E-08 6.22E-05 l.48E-04 l.21E-04

0.

4.79E-05 l.59E-05 2.59E-06 l.95E-05 l.80E-05 7.99E-06

0.

6.81E-06 2.04E-06 4.21E-07 6.51E-06 2.57E-05 1.85E-05

0.

l.43E-05 l.96E-06 2.92E-06 7.97E-05 l.09E-04 7.14E-05

0.

3.70E-05 l.23E-05 2.llE-06 6.52E-08 l.09E-07 5.40E-08

0.

8.0lE-08 7.91E-09 4.65E-13 3.41E-08 5.08E-08 1.85E-08

0.

4.07E-08 3.70E-09 l.lOE-30 9.70E-08 6.91E-ll 2.84E-09

0.

6.46E-11 3.92E-ll l.72E-07 2.03E-05 2.55E-08 1.33E-06

0.

8.67E-09 l.46E-08 4.18E-05 4.71E-08 3.56E-ll l.59E-09

0.

3.31E-ll 2.02E-ll 2.22E-17 2.13E-08 2.19E-ll l.34E-09

0.

l.85E-ll l.24E-ll 3.00E-26 2.50E-09 l.26E-09 3.33E-10

0.
0.
0.

9.25E-05 3.19E-10 9.90E-ll 1.62E-ll

0.
0.
0.

l.18E-05 l.28E-10 5.82E-ll 1.45E-ll

0.
0.
0.

4.25E-07 9.36E-09 6.33E-09 7.18E-10

0.

2.94E-09 0.

2.42E-05 l.65E-09 l.22E-06 1.35E-10

0.

5.37E-10 0.

4.56E-05 4.88E-07 2.04E-07 2.62E-08

0.

l.21E-07 0.

l.65E-04 9.20E-09 3.69E-09 4.56E-10

0.

2.13E-09 0.

4.03E-05 3.0lE-11 l.25E-11 1.53E-12 O.

7.05E-12 0.

4.33E-18 6.29E-09 7.27E-09 4.35E-10

0.

4.25E-09 0.

3.49E-05 7.54E-08 7.09E-09 2.87E-09

0.

1.34E-08 0.

8.93E-06 3.07E-08 7.95E-09 6.08E-09

0.

1.20E-08 0.

6.74E-05 7.17E-09 l.19E-09 5.99E-10

0.

2.25E-09 0.

9.35E-05 1.52E-09 2.15E-10 8.78E-11

0.

4.06E-10 0.

4.03E-05 6.97E-10 1.17E-10 5.91E-11

0.

2.09E-10 0.

3.22E-05 6.90E-08 l.19E-08 2.85E-09

0.

1.33E-08 0.

5.25E-06 8.57E-10 7.15E-10 5.22E-ll

0.

2.31E-10 0.

2.55E-05 1.95E-07 4.44E-08 3.90E-08

0.

2.75E-07 0.

2.56E-05 6.15E-07 7.56E-08 5.38E-08

0.

3.62E-07 0.

5.48E-05 8.60E-08 1.22E-08 7.87E-09

0.

5.63E-08 0.

9.60E-06 1.37E-08 l.06E-08 1.71E-09

0.

7.08E-09 0.

7.26E-05 4.70E-08 0.

5.86E-09

0.

1.94E-08 0.

4.33E-05 2.70E-07 8.43E-08 6.40E-08

0.

1.26E-07

  • 0.
0.

9.91E-09 3.23E-09 3.46E-10

0.
0.
0.

3.68E-07 4.0SE-07 1.35E-07 1.42E-08

0.
0.
0.

1.56E-05 l.03E-07 8.61E-08 3.0lE-08

0.
0.
0.

2.82E-05 84

(.

~

PALISADES NUCLEAR PLANT OFFSITE DOSE CALCULATION MANUAL Revision 9 TABLE 2.1 ADULT INGESTION DOSE COMMITMENT FACTORS (MREM/50Y PER PCI INGESTED IN FIRST YR)

ISOTOPE BONE LIVER TOTAL BODY THYROID KIDNEY LUNG GI -LU PB210+0 l.53E-02 4.37E-03 5.44E-04

0.

l.23E-02 0.

5.42E-05 BI210+0 4.61E-07 3.18E-06 3.96E-08

0.

3.83E-05 0.

4.75E-05 P0210 3.56E-04 7.56E-04 8.59E-05

0.

2.52E-03 0.

6.36E-05 RN222+0

0.
0.
0.
0.
0.
0.
0.

RA223+0 4.97E-03 7.65E-06 9.94E-04

0.

2.17E-04 0.

3.21E-04 RA224+0 1.61E-03 3.90E-06 3.23E-04

0.
l. lOE-04 0.

3.40E-04 RA225+0 6.56E-03 7.78E-06 l.31E-03

0.

2.21E-04 0.

3.06E-04 RA226+0 3.02E-Ol 5.74E-06 2.20E-Ol

0.
1. 63E-04 0.

3.32E-04 RA228+0 1.12E-01 3.12E-06

1. 21E-01
0.

8.83E-05 0.

5.64E-05 AC225 4.40E-06 6.06E-06 2.96E-07

0.

6.90E-07 0.

4.07E-04 AC227+0 l.87E-03 2.48E-04 l.llE-04

0.

8.00E-05 0.

8.19E-05 TH227+0 l.37E-05 2.48E-07 3.95E-07

  • o.

l.41E-06 0.

5.40E-04 TH228+0 4.96E-04 8.40E-06 1.68E-05

0.

4.67E-05 0.

5.63E-04 TH229 7.98E-03 1.19E-04 3.91E-04

0.

5.75E-04 0.

5.12E-04 TH230 2.06E-03 l.17E-04 5.70E-05

0.

5.65E-04 0.

6.02E-05 TH232+0 2.30E-03 1. OOE-04

  • 1.50E-04
0.

4.82E-04 0.

5.12E-05 TH234 8.0lE-08 4. 71E-09 2.31E-09

0.

2.67E-08 0.

1.13E-04 PA231+0 4.lOE-03 1.54E-04

1. 59E-04
0.

8.64E-04 0.

7.17E-05 PA233 5.26E-09 l.06E-09 9.12E-10

0.

3.99E-09 0.

l.64E-05 U232+0 4.13E-03 0.

2.95E-04

0.

4.47E-04 0.

6.78E-05 U233+0

8. 71E-04 0.

5.28E-05

0.

2.03E-04 0.

6.27E-05 U234 8.36E-04 0.

5.17E-05

0.

1.99E-04 0.

6.14E-05 U235+0 8.0lE-04 0.

4.86E-05

0.

l.87E-04 0.

7.81E-05 U236 8.0lE-04 0.

4.96E-05

0.
1. 91E-04 0.

5.76E-05 U237 5.52E-8

0.

l.47E-08

0.

2.27E-07 0.

1.94E-05 U238+0 7.67E-04 0.

4.54E-05

0.
1. 75E-04 0.

5.50E-05 NP237+0

1. 37E-03 l.19E-04 5.54E-05
0.

4.12E-04 0.

7.94E-05 NP238 1.37E-08 3. 69E-10 2.13E-10

0.
1. 25E-09 o:

3.43E-05 NP239 l.19E-09 1.17E-10

6. 45E-11
0.

3.65E-10 0.

2.40E-05 PU238 6.80E-04 9.58E-05 l.71E-05

0.

7.32E-05 0.

7.30E-05 PU239 7.87E-04 l.06E-04 l.91E-05

0.

8.llE-05 0.

6.66E-05 PU240 7.85E-04 1.06E-04 l.91E-05

0.

8.lOE-05 0.

6.78E-05 PU241+0 1.65E-05 8.44E-07 3.32E-07

0.

l.53E-06 0.

l.40E-06 PU242 7.29E-04 l.02E-04

1. 84E-05
0.

7.BlE-05 0.

6.53E-05 PU244 8.52E-04 l.17E-04 2.11E.:05

0.

8.95E-05 0.

9.73E-05 AM241 8.19E-04 2.88E-04 5.41E-05

0.

4.07E-04 0.

7.42E-05 AM242M 8.24E-04 2.78E-04 5.43E-05

0.

4.05E-04 0.

9.34E-05 AM243 8.lBE-04 2.78E-04 5.30E-05

0.

3.99E-04 0.

8.70E-05 CM242 2.06E-05 2.lOE-05 l.37E-06

0.

6.22E-06 0.

7.92E-05 CM243 6.39E-04 2.41E-04 3.75E-05

0.
1. 75E-04 0.

7.81E-05 CM244 4.83E-04 2.07E-04 2.87E-05

0.

l.34E-04 0.

7.55E-05 CM245

1. 02E-03 2.87E-04 5.76E-05
0.

2.69E-04 0.

7.04E-05 CM246 l.OlE-03 2.87E-04 5.75E-05

0.

2.68E-04 0.

6.91E-05 CM247+0 9.84E-04 2.83E-04 5.67E-05

0.

2.64E-04 0.

9.09E-05 CM248 8.18E-03 2.33E-03 4.67E-04

0.

2.lBE-03 0.

l.47E-03 CF252 2.64E-04 0.

6.29E-06

0.
0.
0.

2.88E-04 85

PALISADES NUCLEAR PLANT

)

OFFSITE DOSE CALCULATION MANUAL Revision 9 TABLE 2.2 PALISADES Liquid Effluent Design Objective Annual Quantity Design Objective Dose Conversion Annual Quantity Nuclide Half-Life Factors (mrem/Ci)

Individual/Organ (Curies)

H-3 12.3 yr

1. 75E-06 Adult/TB
1. 71E+06.

Na-24 15 h 5.44E-03 Teen/TB 551.5 Sc-46 83.9 d 2.02E-02 Teen/TB 148.5 Cr-51 27.8 d 1.56E-03 Adult/GI CLLI) 6.410.0 Mn-54 303 d 3.50E-02 Teen/TB 85.7 Fe-55 2.6 yr 4.48E-03 Child/Bone 2.232.0 Mn-56 2.576 h 1.86E-03 Teen/TB 1.612.b Co-57 270 d 4.39E-03 Teen/TB 683.4 Co-58 71.3 d

1. 03E-02 Teen/TB 291.3
  • Fe-59 45.6 d 4.08E-02 Adult/GI (LU) 245.1 Co-60 5.26 yr 4.71E-Ol Teen/TB 6.37 Cu-64 12.8 h 1.32E-03 Teen/GI ( LLI) 7.575.0 Ni-65 2.56 h 5.82E-04 Teen/TB 5.154.0 Zn-65 245 d
1. 83E-01 Teen/TB 16.4 Br-84
31. 8 mo 2.02E-03 Teen/TB 1.485.2 Rb-86
1. 02 mo 3.06E-01 Child/TB 9.80 Rb-88 17.8 mo 6.92E-04 Teen/TB 4.335.3 Sr-89 52.7 d 1.56E-Ol Child/Bone 64.1 Sr-90 27.7 yr 2.71E-OO Adult/Bone 3.69 Sr-91 9.67 h 1.16E-03 Teen/TB 2.586.0 Sr-92
2. 71 h 1.51E-03 Teen/TB
1. 986. 8 Y-92 3.53 h 2.69E-04 Teen/TB 11.150. 0 Nb-95 35 d 7.24E+OO Adult/GI (LLI) 1.38 Zr-95 65.5 d 6.17E-03 Teen/TB 486.2 Nb-97 72 mo 6.95E-04 Teen/TB 4.316.6 Zr-97 17 h 9.28E-04 Teen/TB 3.232.8 Mo-99 66.7 h
1. llE-03 Teen/Kidney 9.009.0 Tc-99m 6.05 h 1.42E-04 Teen/TB 21.126.8 Ru-103 39.5 d 2.74E-03 Teen/TB.

1.094.9 Ag-llOm 255 d 7.75E-02 Teen/TB 38.7

  • 86

87

I l

PALISADES NUCLEAR PLANT OFFSITE DOSE CALCULATION MANUAL I I I.,

URANIUM FUEL CYCLE DOSE A.

SPECIFICATION Revision 9 In accordance with Appendix A.Section III.I.l. if either liquid or gaseous quarterly releases exceed the quantity which would cause offsite doses more than twice the limit of Appendix A. Sections III.C.1. III.0.1, or III.H.1. then the cumulative dose contributions from combined release plus direct radiation sources (from the reactor unit and radwaste storage tanks) shall be calculated.

The dose is to be determined for the member of the public protected to be the most highly exposed to these combined sources.

B.

ASSUMPTIONS

1.

The full time resident determined to be maximally exposed individual (excluding infant) is assumed also to be a fisherman.

This individual is assumed to drink water and ingest local fish at the rates specified in Sections II.C.2.1 and II.C.2.2.

2.

Amount of shore line fishing (at accessible shoreline adjacent to site security fence) is conservatively assumed as 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> per quarter (average of approximately 1/2 hour per day each day of the quarter) for the second and third quarters of the year. 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br /> for the fourth quarter and 16 hours1.851852e-4 days <br />0.00444 hours <br />2.645503e-5 weeks <br />6.088e-6 months <br /> for the first quarter.

C.

DOSE CALCULATION Maximum doses to the total body and internal organs of an individual shall be determined by use of LADTAP and GASPAR computer codes. and doses to like organs and total body summed.

Added to this sum will be a mean dose rate. calculated or measured for the shoreline due to Plant present cur~ng the quarter in question. times the assumed fishing time.

040 = OG + OL + (RT) (T) where:

(2.15) 040 40 CFR 190 dose (mrem).

=

=

T

=

Limiting dose to an individual from gaseous source term (mrem).

Limiting dose to an individual from liquid source term (mrem).

Mean dose rate calculated to be applicable to Lake Michigan shoreline adjacent to Plant site (mrem/hr).

Assumed shoreline fishing time for the quarter in questions (hours).

88

~.....

. ~

. ~

" ) -

~

~I,,

Procedure No ODCM

. **.Appendix A* *

.Revisio*n 3 Issued Date 03/17/95

~-- -_;- -

~----:--

\\,-: :* -

~-

--:"~~~*-*--.-_ -;-*--:-:;-

'.:.. PALISADES.NUCLEAR ~PLAN+ -- " ~-~ -~ ~ -- --- ----- -

. OFFSITE DOSE CALCULATION MANUAL~__

-ftfLE°-:- *

  • REL6CATED TECHNICAL SPECIFICATIONS

_., -::*< * **PER. NRC GENERIC LEITER.

  • --,:* --. --.::-. - :_~_.:

L

./.T ~.:. -

'~..

. -* ' a~~Jij~ ~i~~r 1

.. ~ -'

~.

  • ~*....

2 ~Zi~ q5 _.:... *

.Date

/> ;J--.. ~:{. *: - *--.

,.........,.,:tGV*_, I d- '-' /ff

.Date

iV/4 I

I User Reviewer Date Rev#

I.

INTRODUCTION e

I e

I I

I I

I I

I 1

I I

I 1

Table of Contents II.

DEFINITIONS 1

A.

Channel Calibration l

B.

Channel Check 1

liannel Functional Test l*
  • -.--~ --

D.

Source Check 2

E.

Offsite Dose Calculation Manual 2

F.

Gaseous Radwaste Treatment System 2

G.

Members of the Public 2

H.

Process Control Program (PCP) 2 I.

~ite Boundary 2

J.

Unrestricted Area 2

K.

Ventilation Exhaust Treatment System 3

III.

PROCEDURAL AND SURVEILLANCE REQUIREMENTS AND BASES 3

3 3

A.

Radioactive Gaseous Effluent Monitoring Instrumentation

1.

Requirement

2.

Action 3

3.

Surveillance Requirements 3

4.

Bases...

4

  • B.

Gaseous Effluents Dose Rate 9

1.

Requirement 9

2.

Action 9

3.

Surveillance Requirements 9

4.

Bases 9

C.

Noble Gases Dose 10

1.

Requirement 10

2.

Action 10

3.

Surveillance Requirements 11

4.

Bases.

11 D.

I-131. I-133. Tritium. and Particulates 11

1.

Requirement............

11 i

E.

F.

G.

H.

I.

J.

2.
3.
4.

Action Surveillance Requirements Bases Gaseous Waste Treatment System

1.
2.

3; Requirement Action

4.

Bases

12.

12 12 16 16 16

-* -----~*

=-==='-- l6 16 Radioactive Liquid Effluent Monitoring Instrumentation 17 17 17 17 17 22 22 22

1.

Requirement Action

2.
3.

Surveillance Requirements

4.

Bases Liquid Effluents Concentration

1.

Requirement

2.

Action

3.

Surveillance Requirements

4.

Bases Liquid Effluent Dose

1.

Requirement Action

2.
3.

Surveillance Requirements

4.

Bases Total Dose

1.

Requirement

2.

Action

3.
4.

Surveillance Requirements Bases R&diological Environmental Monitoring

1.

Requirement 2

Action

3.
4.

Surveillance Requirements Bases

a.
b.

Monitoring Program Land Use Census ii 22 22 26 26 26 26 26 27 27 27 28 28 29 29 29 30 31 31 31

IV.

c.

Interlaboratory Comparison Program K.

SIRW or Tem12orary Liguid Storage Tank

1.
  • Requirement
2.

Action

3.

Surveillance Requirement

4.

Bases REPORTING REQUIREMENTS A.

B.

c.

Radiological Effluent Release. Report

1.

Supplemental Information

2.

Gaseous Effluents

3.

Liquid Effluents

4.

Radiological Impact on Man

5.

ODCM Changes Radiological Environmental Operatin~ Renort Nonroutine Reports 32 43 43 43 43 43 45 45 45 46 47 48 49 49 so V.

¥.AJOR MODIFICATIONS TO RADIOACTIVE LIQUID AND GASEOUS WASTE..... 53 TREATMENT SYSTEMS TABLES A-1 A-2 B-1 C-1 A.

B.

Licensee Modifications Definition of Major Radwaste System Modification

1.
2.

Purpose Definition Radioactive Gaseous Effluent Monitoring Instrumentation.

Radioactive Gaseous Effluent Monitoring Instrumentation Surveillance Requirements Radioactive Gaseous Waste Sampling and Analysis Program Radioactive Liquid Effluent Monitoring Instrumentation iii 53 53 53 53 5

7 14 18 I

C-2 D-1 E-1 E-2 E-3

i_.*:..1 Radioactive Liquid Effluent Monitoring Instrumentation

....... 20 Surveillance Requirements Radioactive. Liquid Waste Sampling and Analysis Program 24 Radiological Environmental Monitoring Program..

Reporting Levels for Radioactivity Concentrations in Environmental Samples Detection Capabilities for Environmental Sample Analysis mrv1ronmerital Radiological Monitorin~ l:'rog:i:.au..

~'UlfuJlar:y..

iv 33 39 40 51

I.

Relocated Technical Specifications INTRODUCTION The NRC, through 10CFR50. 36a, requires implementation of Technical Specifications on effluents from nuclear power plants.

NRC Generic Letter 89-01, dated January 31, 1989, allowed relocation of the existing procedural requirements from the Technical Specifications (implemented in Amendment 85, Novernb<>..-

9, J.q84).

The relocated proce!lural requirements related to gaseous and liquid effluents, total dose, environmental monitoring program, and associated procedural reporting requirements follow below.

Programmatic controls are retained in the Administrative Controls section of the Technical Specification to satisfy the regulatory requirements of 10CFR50. 36a. The Technical Specifications programmatic controls include requirements for the establishment, implementation, maintenance, and changes to the Offsite Dose Caiculation Manual (ODCM) as well as record retention and reporting requirements.

II.

DEFINITIONS A.

B.

c.

Channel Calibration a

Channel Calibration shall be the adjustment, as necessary, of the channel output such that it responds with the necessary range and accuracy to known values of the parameter which the channel monitors. The Channel Calibration shall encompass the entire channel including the sensor and alarm and/or trip functions, and shall include the Channel Function Test.

The Channel Calibration may be performed by any series of sequential, overlapping or total channel steps such that the entire channel is calibrated.

Channel Check A Channel Check shall be the qualitative assessment of channel behavior during operation by observation.

This determination shall include, where possible, comparison of the channel indication and/or status with.other indications and/or status derived from independent instrumentation channels measuring the same parameter.

Channel Functional Test - a Channel Functional Test shall be:

1.

Analog channels - the injection of a simulated signal into the channel as close to the sensor as practicable to verify operability including alarm and/or trip functions.

2.

Bistable channels - the injection of a simulated signal into the sensor to verify operability including alarm and/or trip functions.

1 Rev 3 12/05/94

D.

Source Check - a source check shall be the qualitative assessment of channel response when the channel sensor is exposed to a radioactive source.

E.

Offsite Dose Calculation Manual (per Plant Technical Specification) - the Offsite Dose Calculation Manual (ODCM) shall contain the methodology and parameters used in the calculation of offsite doses resulting from radioactive gaseous and liquid effluents, in the calculation of gaseous and liquid effluent monito:r.:i.ng alarm/trip setpoints, and in the conduct of the Radiological Environmental Monitoring Program.

The ODCM shall also contain;

1) the Radioactive Effluent Controls and Radiological Environmental Monitoring Programs required by the Technical Specifications and, 2) descriptions of the information that should be included in the Annual Radiological Environmental Operating and Radioactive Effluent Release Reports required by the Technical Specifications.

F.

Gaseous Radwaste Treatment System -

any system designed and installed to reduce radioactive gaseous effluents by collecting primary coolant system off gases from the primary system and providing for delay* or holdup for the purpose of reducing the total radioactivity prior to release to the environment.

G.

Members of the Public -

all persons who are not occup.ationally associated with the Plant.

This category does not include employees of the utility, its contractors or vendors.

Also excluded from this category are persons who enter the site to service equipment or to make deliveries.

H.

Process Control Program (PCP) - shall contain the current formula, sampling, analyses, tests and determinations to be made to ensure that the processing and packaging of solid radioactive wastes based on demonstrated processing of actual or simulated wet solid wastes will be accomplished in such a way. as to assur*e compliance with 10CFR Part 20, 10CFR Part 71 and Federal and State regulations and other requirements governing the disposal of the radioactive waste.

I.

Site Boundary - that line beyond which the land is neither owned nor otherwise controlled by the licensee.

J.

Unrestricted Area - any area at or beyond the Site Boundary acces.s which is not controlled by the licensee for purposes of protection of individuals from exposure to radiation and radioactive materials or, any area within the Site Boundary used for residential quarters or for industrial, commercial, institutional, and/or recreational purposes.

2 Rev 3 12/05/94

K.

Ventilation Exhaust Treatment System -

any system designed and installed to reduce gaseous radioiodine or radioactive material in particulate form in effluents by passing ventilation or vent exhaust gases through charcoal adsorbers and/or HEPA filters for the purpose of removing iodines or particulates from i.;he gas*:H:>us exhaust stream prior to the release to the environment.

Such a system is not considered to have any effect on noble gas effluents.

Engineered Safety Feature (ESF) atmospheric cleanup systems are not considered to be yentilation exhaust treatment

~y~tem components.

III.

PROCEDURAL AND SURVEILLANCE REQUIREMENTS AND BASES A.

Radioactive Gaseous Effluent Monitoring Instrumentation

1.

Requirement:

2.

The radioactive gaseous effluent monitoring instrumentation channels shown in Table A-1 shall be operable with theii alarm/trip setpoints set to ensure that the limits of requirement Ill.B.l are not exceeded.

The alarm/trip setpoints of these channels shall be determined and adjusted in accordance with the methodology and parameters in the ODCM.

Action:

a.

With a radioactive gaseous effluent monitoring instrumentation channel alarm/trip setpoint less conservative than required by the above requirement, without delay, suspend the release of radioactive gaseous effluents monitored by the affected channel or declare the channel inoperable or change the setpoint so it is acceptably conservative.

b.

With less than the minimum number of radioactive gaseous effluent monitoring instrumentation channels operable, take the action shown in Table A-1.

Exert best efforts to return the instruments to operable status within 30 days

and, if unsuccessful, explain in the next Radioactive Effluent Release Report why the inoperability was not corrected in a timely manner.
3.

Surveillance Requirements:

Each radioactive gaseous effluent monitoring instrumentation channel shall be demonstrated operable by performance of the Channel Check, Source Check, Channel Calibration and Channel Functional Test operations at the 3

Rev 3 12/05/94

4.

frequencies shown in Table A-2.

Bases:

The radioactive gaseous effluent instrumentation is provided to monitor and control, as applicable, the releases of radioactive materials in gaseous effluents during actual or potential releases of gaseous effluents.

The alarm/trip setpoints for these instruments shall be calculated and adjusted in accordance with the methpd9logy and parameters in the ODCM to ensure that the alarm/trip will occur prior to exceeding the limits of 10CFR Part 20.

The operability and use of this instrumentation is consistent with the requirements of General Design Criteria 60, 63, and 64 of Appendix A to 10CFR Part 50.

4 Rev 3 12/05/94

Table A-1 RADIOACTIVE GASEOUS EFFLUENT MONITORING INSTRUMENTATION INSTRUMENT

1.

WASTE GAS HOLDUP SYSTEM

a.

Noble Gas Activity Monitor (RIA 1113).Providing Alarm and Automatic Termination of Release

b.

Effluent System Flow Rate Measuring Device (FI 1121)

MINIMUM,.

( 1)

(1)

2.

CONDENSER EVACUATION SYSTEM (RIA 0631)

a.

Noble Gas Activity Monitor

3.

STACK GAS EFFLUENT SYSTEM

a.

Noble Gas Activity Monitor (RIA 2326)

b.

Iodine/Particulate/Sampler/

Monitor (RIA 2325)

c.

Sampler Flow Rate Monitor

d.

Hi Range Noble Gas (RIA 2327)*

4 *.

STEAM GENERATOR BLOWDOWN VENT SYSTEM

a.

Noble Gas Activity Monitor (RIA 2320) 5.

MAIN STEAM SAFETY AND DUMP VALVE DISCHARGE LINE

a.

Gross Gamma Activity Monitor *

(RIA 2323 and 2324)

6.

ENGINEERED SAFEGUARDS ~!ROOM VENTmfA~!!II~n+Mmrm~uii SYSTEM

a.

Noble Gas Activity Monitor **

(RIA 1810 and 1811)

(1)

(1)

(1)

(1)

(1)

(1) 1 per Main Steam Line 1

per room APPLICABILITY At All Times At All Times Above 210°F At All Times At All Times At All Times Above 210°F Above 210°F Above 325°F Above 210°F ACTION 1

2 3

3 3

2 4

3 4

  • Setpoints for these instruments are exempted from III.B.1 limits, but are governed by Emergency Implementing Procedures or Operating procedures.
    • Setpoints for these instruments are exempted from III.B.1 limits, but are governed by Technical Specification l¥.iff§.fi!@:\\M and Table i:M§@fm!@§fiP.fftj@:f,f.ffilWffii~!!l~KJW~\\ti:!}.tt!@§!~!§!?,~gf#,Mff:AfH!~f:M:f!J;H@}fff.11 5

Rev 3 12/05/94

ACTION 1 -

ACTION 2 ACTION 3 ACTION 4 ACTION 5 Table A-1 (cont'd)

TABLE NOTATION - ACTION STATEMENTS With the number of channels operable less than required by the Minimum Channels Operable requirements, the contents of the tank(s) may be released to the environment provided that prior to initiating the release:

a.

at least two independent samples of the tank's contents are analyzed, and

b.

at least two technically qualified members of the Facility staff independently verify the release rate calculations and discharge valve line up; otherwise, suspend release of radioactive effluents via this pathway.

With the number of channels operable. less than required by the Minimum Channels Operable requirement, effluent releases via this pathway may continue provided the flow rate is estimated at least once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> for continuous releases or four hours for batch releases.

With the number of channels operable less than required by the Minimum Channels Operable requirement, effluent releases via this pathway may continue provided grab samples are taken at least once per 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> and these samples are analyzed for gross activity within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

With the number of operable channels less than requii;ed by the Minimum Channels Operable requirements, initiate the preplanned alternate method of monitoring the appropriate parameter(s), within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br />, and:

a.

either restore the inoperable channel(s) to operable status within 7 days of the event, or

b.

prepare and submit a Special Report to the NRG within 30 days following the event outlining the actions taken, the cause of the inoperability and the plans and schedule for restoring the system to operable status.

If either channel fails low or is otherwise inoperable, the ventilation dampers associated with that channel shall be closed immediately and action shall be taken to have the affected channel repaired.

The dampers associated with the channel shall not be opened until the affected channel has been declared operable.

~11:1~sinsfif:~~$tln1%si:t.]:!~!:1:11~11:F:lin:Ia::IitM::a:t.:tt:~:~1:

6 Rev 3 12/05/94

Table A-2 RADIOACTIVE GASEOUS EFFLUENT MONITORING INSTRUMENTATION SURVEILLANCE REQUIREMENTS INSTRUMENT

1.

WASTE GAS HOLDUP SYSTEM

a.

Noble Gas Activity Monitor-Providing Alarm and Automatic Termination of Release

b.

WGDT Effluent Flow Rate Device

2.

CONDENSER EVACUATION 3YSTEM

a.

Noble Gas Activitj Monitor

3.

STACK GAS EFFLUENT SYSTEM

a.

Noble Gas Activity Monitor

b.

Iodine Particulate Sampler/Monitor

c.

Sampler Flow Rate Monitor

d.

Hi Range Noble Gas

4.

STEAM GENERATOR BLOWDOWN VENT SYSTEM

a.

Noble Gas Activity Monitor CHANNEL CHECK D(4)

D(4)

D D

w D

D D

SOURCE CHEg p

NA M

M M**

NA M

M

  • At all times other than when the line is valved out and locked.
    • Sampler not applicable'.

7 CHANNEL CALIBRATION R(3)

R R(3)

R(3)

R(3)**

R R(3)

R(3)

CHANNEL FUNCTIONAL TEST Q(l)(2)

NA Q(2)

Q(2)

NA NA Q(2)

Q(2)

MODES IN WHICH SURVEILI.ANCE REQUIRED Above 210°F Above 210°F Above 210°F Rev 2 01/05/94

5.
6.

Table A-2 (Cont'd)

RADIOACTIVE GASEOUS EFFLUENT MONITORING INSTRUMENTATION SURVEILLANCE REQUIREMENTS INSTRUMENT MAIN STEAM SAFETY AND DUMP VALVE DISCHARGE LINE

a.

Gross Gamma Activity Monitor ENGINEERED SAFEGUARDS ~

ROOM vENTIJl!w9.B~:::B~~u:::::~+~w;~li SYSTEM

a.

~tl~~iii~tttti@i¥@t~tw:i::tMt~t~Mi,#.HU CHANNEL CHECK D

SOURCE CHANNEL CHECK CALIBRATION M

R(3)

M R(3)

TABLE NOTATION CHANNEL FUNCTIONAL TEST Q(2) i.4(1) (2" I

MODES IN WHICH SURVEILLANCE REQUIRED Above 325°F Above 210°F (1)

The Channel Functional Test shall also demonstrate that automatic isolation of this pat~way occurs if instrument indicates measured levels above the alarm/trip setpoint.

(2)

The Channel Functional Test shall also demonstrate that control room alarm annunciatio~ occurs if either of the following conditions exists.

a.

Instrument indicates measured levels above the alarm setpoint (not *applicable for Item 3.d, Hi Range Noble Gas).

b.

Circuit failure.

(3)

a.

The Channel Calibration shall be performed using one or more of the reference standards traceable to the National Institute of Standards and Technology or using standards that have been obtained from.suppliers that participate in measurement assurance activities with NIST.

These standards shall permit calibrating the system over its intended range of energy and measurement range.

b.

For subsequent Channel Calibration, sources that have been related to the (1) calibration may be used.

  • (4)

Channel Check shall consist of verifying indication of flow during periods of release.

C~annel Check shall be made at least once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> on days on which continuous or batch releases are made.

I!

D M

p TABLE FREQUENCY NOTATION N:l.%W:ii.!11*19:1tll~tW.~If.l§gg1 At least once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> Q

At least once per 31 days R

Prior to radioactive batch release W

At least once per ~2 days At least once per* ~8 months At least once per :.1eek Rev 2. 01/05/94

B.

Gaseous Effluents Dose Rate

1.

Requirement:

The dose rate due to radioactive materials released in gaseous effluents from the site to areas at and beyond the Site Boundary (see Figure 2-1) shall be limited to the foilowing:

a.

~or noble gases:

Less -than or. equ... -_ :

'~

  • w.J:ews/yr to the total body and less than or equal to 3000 mrems/yr to the skin, and
b.

For Iodine-131, for Iodine-133, for tritium and for all radionuclides in particulate form with half-lives greater than 8 days:

Less than or equal to 1500 mrems/yr to any organ.

2.

Action:

With the dose rate(s) averaged over a period of one hour exceeding the above limits, without delay, restore the release rate to within the above limit(s).

3.

Surveillance Requirements:

a.

The dose rate due to noble gases in gaseous effluents shall be determined to be within the limits of B.l.a in accordance with the methodology and parameters in the ODCM.

b.

The dose rate due to Iodine-131, Iodine-133, tritium, and all radionuclides in particulate form with half-lives greater than 8 days in gaseous effluents shall be determined to be within the limits of B.1.b in accordance with the methodology and parameters in the ODCM by obtaining representative samples and performing analyses in accordance 'with the sampling and analysis program specified in Table B-1.

4.

Bases:

This is provided to ensure that the dose at any time at and beyond the Site Boundary from gaseous effluents from all units on the site will be within 10 times the annual dose limits of 10CFR Part 20 to Unrestricted Areas. The annual dose limits are the doses associated with the concentrations of 10 times 10CFR Part 20, Appendix B, Table 2, Column l; These restrictions provide reasonable assurance that radioactive material discharged in gaseous effluents will not result in the exposure of a Member of the Public in an Unrestricted Area, either within or outside the Site Boundary, to annual exposure greater than design objectives of 10CFR 50, Appendix I,

Section II. B. 1.

  • For Members of the Public who may at times be within the Site Boundary, the occupancy of the Member of the Public 9

Rev 2 01/05/94

will usually be sufficiently low to compensate for any increase in the atmospheric diffusion factor above that for the Site Boundary.

Examples of calculations for such Members of the Public, with the appropriate occupancy factors, shall be given in the ODCM.

The specified release rate limits restrict, at all

times, the corresponding dose rate above background to a Member of the Public at or beyond-the Site Boundary to less than or equal to 500 mrems/yr to the total body.

The required detection capabilities for radioactive materials in gaseous waste samples are tabulated in terms of the lower limits of detection (LLD' s).

Detailed discussion of the LLD.and other detection limits can be found in HASL Procedures Manual, HASL-300 (revised annually), Currie, LA, "Limits for Qualitative Detection and Quantitative Determination - Application to Radiochemistry,"

Anal Chem 40, 586-93 (1968), and Hartwell, J K, "Detection Limits for Radioanalytical Counting Techniques," Atlantic Richfield Hanford Company Report ARH-SA-215 (June 1975).

C.

Noble Gases Dose

1.

Requirement:

The air dose due to noble gases released in gaseous effluents to areas at and beyond the Site Boundary (see Figure 2-1) shall be limited to the following:

a.

During any calendar quarter:

Less than or equal to 5 mrads for gamma radiation and less than or equal to 10 mrads for beta radiation, and

b.

During any calendar year:

Less than or equal to 10 mrads for gamma radiation and less than or equal to 20 mrads for beta radiation.

2.

Action:

With the calculated air dose from radioactive noble gases in gaseous effluents exceeding any of the above limits, prepare and submit to the NRC within 30 days a Special Report that identifies the cause(s) for exceeding the limit(s) and defines the corrective actions that have been taken to reduce the releases and the proposed corrective actions to be taken to assure that subsequent releases will be in compliance with the above limits.

10 Rev 2 01/05/94

3.
4.

Surveillance Requirements:

Cumulative dose contributions for the current cal.:;nd.a.r quarter and current calendar year for noble gases shall be determined in accordance with the methodology and parameters in the ODCM at least once per 31 days.

Bases:

This requirement is provided to implement the requirements of Sections II.B, III.A, and IV.A of Appendix I, 10CFR Part 50.

The limiting Condition for Operation implements the guides set forth in Section II. B of Appendix I.

The Action statements provide the required operating flexibility and at the same time implement the guides set forth in Section IV.A of Appendix I to assure that the releases of radioactive material in gaseous effluents to Unrestricted Areas will be kept "as low as is reasonably achievable. n The Surveillance Requirements implement the requirements in Section III.A of Appendix 1 that conformance with the guides of Appendix I be shown by calculational procedures based on models and data such that the actual exposure of a Member of the Public through appropriate pathways is unlikely to be substantially underestimated.

The dose calculation methodology and parameters established in the ODCM for calculating the doses due to the actual release rates of radioactive noble gases in gaseous effluents are consistent with the methodology provided in Regulatory Guide 1.109, "Calculation of Annual Doses to Man from Routine Releases of Reactor Effluents for the Purpose of Evaluating Compliance with 10CFR Part 50, Appendix I,"

Revision 1, October 1977 and Regulator.f Guide 1.111, "Methods for Estimating Atmospheric Transport and Dispersion of Gaseous Effluents in Routine Releases from Light-Water-Cooled Reactors", Revision 1, July 1977. The ODCM equations provided for determining the air doses at and beyond the Site Boundary are based upon the historical average atmospheric conditions.

D.

I-131, I-133. Tritium, and Particulates

1.

Requirement:

The dose to a Member of the Public from Iodine-131, Iodine-133, tritium and all radionuclides in particulate form with half-lives greater than 8 days in gaseous effluents released, from each reactor unit, to areas at and beyond the Site*

Boundary (see Figure 2-1) shall be limited to the following:

a.

During any calendar quarter:

Less than or equal to 7.5 mrems to any organ, and 11 Rev 2 01/05/94

2.
3.
b.

During any calendar year:

mrems to any organ.

Action:

Less than or equal to 15

'With the calculated dose from the release of Iodine-131, Iodlne-133, tritium and radionuclides in particulate form with half-lives greater than 8 days, in gaseous effluents exceeding auy.of the above limits, prepart>.::..... :. ;:_._...,_.:... *-

~o i..he NRC within 30 days a Special Report that identifies the cause(s) for exceeding the limit and define(s) the corrective actions that have been taken to reduce the releases and the proposed corrective actions to be taken to assure that subsequent releases will be in compliance with the above limits.

Surveillance Requirements:

Cumulative dose contributions for the current calendar quarter and current calendar year for Iodine-131, Iodine-133, tritium and radionuclides in particulate form with half-lives greater than 8 days shall be determined in accordance with the methodology and parameters in the ODCM at least once per 31 days.

4.

Bases:

This requirement is provided to implement the requirements of Sections II.C, III.A and IV.A of Appendix I, 10CFR Part 50.

The requirements are the guides set forth in Section II.C of Appendix I.

The Action statements provide the required operating flexibility and at the same time implement the guides set forth in Section IV.A of Appendix I to assure that the releases of radioactive materials in gaseous effluents to Unrestricted Areas will be kept "as low as is reasonably achievable." The ODCM calculational methods specified in the Surveillance Requirements implement the requirements in Section II.A of Appendix I that conformance with the guides of Appendix I be shown by calculational procedures based on models and data, such that the actual exposure of a Member of the Public *through appropriate pathways is unlikely_, to be substantially underestimated.

The ODCM calculational methodology an~ parameters for calculating the doses due to the actual release rates of the subject materials are consistent with the methodology provided in Regulatory Guide 1.109, "Calculation of Annual Doses to Man From Routine Releases of Reactor Effluents for the Purpose of Evaluating Compliance with 10CFR Part 50, Appendix I", Revision 1, October 1977 and Regulatory Guide 1.111, "Methods for Estimating Atmospheric Transport and Dispersion of Gaseous Effluents in Routine Releases From Light-Water-Cooled 12 Rev 2 01/05/94

Reactors", Revision 1, July 1977.

These equations also provide for determining the actual doses based upon the historical average atmospheric conditions.

The n1lf:ase rate requirements for Iodine-131, Iodine-133, tritium and radionuclides in particulat~ form with half-lives greater than 8 days are dependent upon the existing radionuclide pathways to man, in areas at and beyond the Site Boundary.

The pathways that were examined in the development of these calculations were:

T/ * :1.-.i.i:i.v.i..:iual inhalation of airborne radionuclides, 2) deposition of radionuclides onto green leafy vegetation with subsequent consumption by man, 3) deposition onto grassy areas where milk animals and meat producing animals graze with consumption of the milk and meat by man, and 4) deposition on the ground with subsequent exposure of man.

13 Rev 2 01/05/94

GASEOUS RELEASE *TYPE A.

Waste Gas ~torage Tank B.

Containment PURGE

c.

Stack Gas Effluent

'.fable B-J, RADIOACTIVE GASEOUS WASTE SAM~LING AND ANALYSIS PROGRAM SAMPLING FREQUENCY p

Each Tank Grab Sample p

Each PURGE Grab Sample Continuous0 MINIMUM ANALYSIS FREQUENCY p

  • Each Tank p

Each PURGE wd*e Charcoal*

Sample Continuous0 wd*e Continuous0 Continuous0 Particulate Sample Q

Composite Particulate Sample Noble Gas Monitor 14 TYPE OF ACTIVITY ANALYSIS Principal Gamma Emittersb Principal Gamma Emittersb I-13i, I-133 Principal Gamma Emittersb (I-131, Others)

Sr-89, Sr-90 and Gross Alpha Noble Gases Gross Beta or Gamma LOWER LIMIT DETECTION (LLD)a (uCi/mll 1 x 10-4 1 x 10-12 1 x lo-11 1 x 10-11 lE-06 Rev 2 01/05/94

Table B-1 * (Cont'd)

TABLE NOTATION aThe LLD is defined, in Table E-3, note C.

bThe principal gamma emitters for which the LLD specification applies exclusively are the following radionuclides:

Kr-87, Kr-88, Xe-133, Xe; *lJji...,

""e.. 1~5, and Xe-138 for gaseous emissions and Mn-54, Fe-59, Co-58, Co-60, Zn-65, Mo-99*,

Cs-134, Cs-137, Ce-141, and Ce-144* for particulate emissions.

This list does not mean that only these nuclides are to be considered.

Other gamma peaks that are identifiable, together with those of the above nuclides, shall also be analyzed and reported in the Radioactive Effluent Release Report..

  • (LU> lE 10 wru!J&i!~!~ff'IR£\\1lm! because of low gamma yields.

cThe ratio of the sample flow rate to the sample stream flow rate shall be known for the time period covered by each dose or dose rate calculation made in accordance with requirements III.B.l, III.C.l, and III.D.l.

dsamples shall be changed at least once per 7 days and analyses shall be completed within 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> after changing or after removal from sampler.

CW'ith channels operable on iodine monitor RIA 2325 less than required per III. A. l, sampling shall also be performed at least once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> for at least 7 days following each shutdown, start-up or Thermal Power change exceeding 15 percent of Rated Thermal Power in one hour and analyses shall be completed within L~8 hours of changing.

When samples collected for 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> are analyzed, the corresponding LLDs may be increased by a factor of 10. This requirement does not apply if,. 1) analysis shows that the Dose Equivalent I-131 concentration in the primary coolant has not increased more than a factor of 3, and 2) the noble gas monitor shows that effluent activity has not increased more than a factor of 3.

15 Rev 2 01/05/94

E.

Gaseous Waste Treatment System

1.

Requirement:

When gaseous waste exceeds a Xe-133 concentration of lE-05

µCi/cc, the Waste Gas Decay Tank System shall be used to reduce radioactive gaseous effluents by holding gaseous waste collected by the system for a minimum of 15 days up to 60 days.

2.

Action:

a.

If a waste gas decay tank is required to be released with less than 60 days holdup time, the system waste gas tank contents shall be evaluated and the waste gas decay tank with the lowest Xe-133 content shall be released.

b.

Gaseous waste may* be discharged directly from the waste gas surge tank through a high-efficiency filter or from a waste gas. decay tank with less than 15 days of holdup directly to the stack for a period not to exceed 7 days if the holdup system equipment is not available and the release rates meet requirements III.B, C, and D.

3.

Surveillance Requirements:

Not Applicable.

4.

Bases:

The requirement that the appropriate portions of these systems be used, when specified, provides reasonable assurance that the releases of radioactive materials in gaseous effluents will be kept "as low as is reasonably achievable" by meeting the design objectives given in Section II.D of Appendix I to 10CFR50.

It is expected that releases of radioactive materials in effluents shall be kept at small fractions of the limits specified in 20. 1302 of 10CFR20.

At the same time the licensee is permitted the flexibility of operation, compatible with considerations of health and safety, to assure that the public is provided a dependable source of power even under unusual operating conditions which may temporarily result in releases higher than such small fractions, but still within the limits specified in III.B, C, and D.

16 Rev 2 01/05/94

F.

Radioactive Liguid Effluent Monitoring Instrumentation

1.

Requirement:

The radioactive liquid effluent monitoring instrumentation channels shown in Table C-1 shall be operable with their alarm/trip setpoints set to ensure that the limits of III.G are not exceeded.

The alarm/trip setpoints of these channels shall be ~u...:t.ern1.... ned and adjusted in accordance wit~ Li *.:::

methodology and parameters in the Offsite Dose Calculation Manual (ODCM).

2.

Action:

a.

With a

radioactive liquid effluent monitoring instrumentation channel alarm/trip setpoint less conservative than required by the above specification, without delay suspend the release of radioactive liquid effluents monitored by the affected channel or declare the channel inoperable, or change the setpoint so it is acceptably conservative.

b.

With less than the minimum number of radioactive liquid effluent monitoring instrum~ntation channels Operable, take the Action shown in Table C-1.

Exert best efforts to return the instruments to Operable status within 30 days and, Radioactive inoperability if unsuccessful, explain in the next Effluent Release Report why the was not corrected in a timely manner.

3.

Surveillance Requirements:

4.

Each radioactive liquid effluent monitoring instrumentation channel shall be demonstrated Operable by performance of the Channel Check, Source Check, Channel Calibration and Channel Functional Test operations at the frequencies shown in Table C-2.

Bases:

The radioactive liquid effluent instrumentation is provided to monitor and

control, as applicable, the releases of radioactive materials in liquid effluents during actual or potential re leas.es
  • of liquid effluents.

The alarm/trip setpoints for these instruments shall be calculated and adjusted in accordance with the methodology and parameters in the ODCM to ensure that the alarm/trip will occur prior to exceeding the limits of 10CFR Part 20.

The Operability and use of this* instrumentation is consistent with the requirements of General Design Criteria 60, 63, and 64 of Appendix A to 10CFR Part 50.

17 Rev 2 01/05/94

Table C-1 RADIOACTIVE LIQUID EFFLUENT MONITORING INSTRUMENTATIOt-1 INSTRUMENT

1.

GROSS RADIOACTIVITY MONITORS PROVIDING ALARM AND AUTOMATIC TERMINATION OF RELEASE

a.

Liquid Radwaste Effluent Line (RIA 1049)

b.

Steam Generator Blowdown Effluent Line (RIA 0707)

2.

GROSS BETA OR GAMMA RADIOACTIVITY MONITORS PROVIDING ALARM BUT NOT PROVIDING AUTOMATIC TERMINATION OF RELEASE

a.

Service 'Water System Effluent Line (RIA 0833)

b.

Turbine Building (Floor Drains) Sumps Effluent Line (RIA 5211)

3.

FLOW RATE MEASUREMENT DEVICES

a.

Liquid Radwaste Effluent Line (FIC 1051 or 1050)

4.

CONTINUOUS COMPOSITE SAMPLERS (Alarm/Trip Setpoints are not applicable)

a.

Turbine Building Sumps Effluent Line

b.

Service 'Water System Effluent

c.

Steam Generator Blowdown Effluent 18 MINIMUM..

ACTION (1) 1 (1) 2 (1) 3 (1) 3 (1) 4 (1) 3 (1) 3 (1) 3 Rev 2 01/05/94

Table C-1 (Cont'd)

TABLE NOTATION ACTION 1 -

W'ith the number of channels operable less than required by the Minimum Channels Operable requirement, effluent releases may continue provided ti11:1.1. t.i...;.._,, to initiating a release:

a.

At least two independent samples are analyzed in accordance with requirements and

b.

At least two technically qualified members of the Facility Staff independently verify the release rate calculations and discharge line valving; Otherwise, suspend release of radioactive effluents via this pathway.

ACTION 2 -

W'ith the number of channels operable less than required by the Minimum Channels Operable requirement, effluent releases via this pathway ifij continue provided grab samples are analyzed for gEess radioactivity ('eeta eE gamma) at a lower limit of detection ef at

.\\

a;1;;.:~~-!-~i.i~1'-:t !!~~~!1~}:~*!~~!!!i~~i"@~1#faimlfifj ACTION 3 -

With the number of channels operable less than required by the Minimum Channels Operable requirement, effluent releases via this pathway may continue provided.that, at least once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />, grab samples are collected and analyzed for grass radioactivity (ee~a eE gs-a) at a lower limit of detection ef at least 10-7 miene~J;".le/111

  • !1llitlatcc.111~I::11\\~m111111r1@t9:iri£l!stt11i1~1*1;~::r111tJ111T;mrt:!111f:1.

ACTION 4 -

With the number of channels operable less than required by the Minimum Channels Operable requirement, effluent releases via this

- pathway may continue provided the flow rate is estimated at least once per 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> during actual releases. Pump performance curves or tank levels may be used to estimate flow.

19 Rev 2 01/05/94

Table C-2 RADIO,~CTIVE LIQUID EFFLUENT MONITORING INSTRUMENTATION SURVEILLANCE REQUIREMENTS INSTRUMENT

1.

GROSS RADIQACTIVITY MONITORS PROVIDING ALARM AND AUTOMATIC TERMINATION OF RELEASE

a.

Liquid Radwaste Effluent Line (RIA 1049)

b.

Steam Generator Blowdown Effluent Line (RIA 0707)

2.

GROSS BETA OR GAMMA RADIOACTIVITY.MONITORS PROVIDING ALARM BUT NOT PROVIDING AUTOMATIC TERMINATION OF RELEASE

a.

Service Water System Effluent Line (RIA 0833)

b.

Turbine Building (Floor Drains) Sumps Effluent Line (RIA 5211).

3.

FLOW RATE MEASUREMENT DEVICES

a.

Liquid Radw'.iste Effluent Line* (FIC 1051 or 1050)

4.

TURBINE SUMP EFFLUENT COMPOSITER

5.

SERVICE WATER SYSTEM EFFLUENT COMPOSITE SAMPLER

6.

STEAM GENERATOR BLOWDOWN EFFLUENT COMPOSITER 20 CHANNEL

~

p D

D D

D(4)

D(4)

D(4)

D(4)

SOURCE QlliQK p

M M

M NA NA NA NA CHANNEL CALIBRATION R(3)

R(3)

R(3)

R(3)

R NA NA NA Rev 2 CHANNEL FUNCTIONAL TEST Q(1)(2)

Q(1)(2)

Q(2)

Q(2)

NA NA NA NA 01/05/94

Table C-2 (Cont'd)

TABLE NOTATION (1)

The Channel Functional Test shall also demonstrate that automatic isolation of this pathway occurs if instrument indicates measured levels above the alarm/trip setpoint.

(2)

The Channel Functional Test shall also demonstrate that Control Room alarm annunciation occurs if either of the following conditions exists:

a.

Instrument indicates measured levels above the alarm setpoint.

b.

Circuit failure.

(3)

a.

The Channel Calibration shall be performed using one or more of the reference standards traceable to the National Institute of Standards and Technology or using standards that have been obtained from suppliers that participate in measurement assurance activities with NIST.

These standards shall permit calibrating the system. over its intended range. of energy and measurement range.

b.

For subsequent Channel Calibration, sources that have been related to the (a) calibration may be used.

(4)

Channel Check shall consist of verifying indication of flow during periods of releRses.

Channel Check shall be made at least once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> on days on which continuous or batch releases are made.

D M

p TABLE FREQUENCY NOTATION At least once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> At least once per 31 days Prior to radioactive batch release 21 Q

R w

At least once per 92 days At least once per 18 months At least once per week Rev 2 01/05/94

G.

Liquid Effluents Concentration

1.

Requirement:

The concentration of radioactive material released in liquid effluents to Unrestricted Areas shall be limited to 10 times the concentrations specified in 10CFR Part 20, Appendix B, Table 2, Column 2 for radionuclides other than dissolved or entrained *noble gaH~s.

For *dissolved or entrait1ed**'mible

gases, the concentration shall be limited to 2 x 10-4 microcuries/ml total activity.
2.

Action:

With the concentration of radioactive material released in liquid effluents to Unrestricted Areas exceeding the above*

limits, without delay, restore the concentration to within the above limits.

3.

Surveillance Requirements:

a.

Radioactive liquid wastes shall be sampled and analyzed according to the sampling and analysis program of

b.
4.

Bases:

Table D-1.

The results of the radioactivity analysis shall be used in accordance with the methodology and parameters in the ODCM to assure that the concentrations at the point of release are maintained within the limits of G.1 above.

This requirement is provided to ensure that the concentration of radioactive materials released in liquid waste effluents to Unrestricted Areas will be less than 10 times the concentration levels specified in 10CFR Part 20, Appendix B, Table 2, Column 2.

This limitation provides additional assurance that the levels of radioactive materials in bodies of water in Unrestricted Areas will result in exposures within the Section II.A design objectives of Appendix I, 10CFR Part 50, to a Member of the Public.

The concentration limit for dissolved or entrained noble gases is based upon the assumption that Xe-135 is the controlling radioisotope and 10 times the effluent concentration in air (submersion) was c_onverted to an equivalent concentration in water using the methods described in International Commission on Radiological Protection (ICRP) Publication 2.

22 Rev 2 01/05/94

The required detection capabilities for radioactive materials

. in liquid waste samples are tabulated in terms of the lower limits of detection (LLDs).

Detailed discussion of the LLD and other detection limits can be found in HASL Procedures Manual, HASL-300 (revised annually), Currie, LA, "Limits for Qualitative Detection and Quantitative Determination - Application to Radiochemistry", Anal Chem 40, 586-93 (1968),

and Hartwell, J K, "Detection Limits* for

.: --,-.,,...-K"adioancil)'tical

  • Counting Techniques17-a~*1e:t. *.:-.i:;..;.

i.il.~*Zit::ld

  • Hanford Company Report ARH-SA-215 (June 1975).

23 Rev 2 01/05/94

Table D-1 RADIOACTIVE LIQUID WASTE SAMPLING AND ANALYSIS PROGRAM

--I.ii~!~ Release Type A. *-._P.,o_t_c'h_ lJ?.f-t-n Release Tanksb B.

Continuous Releasese (Turbine Sump, Steam Generator Blowdown and Service Water)

Sampling Frequency p

Each Batch p

One *Batch/M p

Each Batch p

Each Batch Continuousf M

Grab Sample Minimum Analysis Frequency p

Each Batch M

M Composited Q

Composited w

Compositef M

M Continuousf Compositef Q

Continuousf Compositef Type of Activity Analysis P'l'."i Tl" i Tl"' 1

(.:<i111m~.

Emittersc I-131 Dissolved and Entrained Gases (Gamma Emitters)

H-3 Gross Alpha Sr-89, Sr-90 Principal Gamma Emittersc I-131 Dissolved and Entrained Gases (Gamma Emitters

. H-3 Gross Alpha Sr-89, Sr-90 FREQUENCY NOTATION P Prior to batch release M *calendar month Q Calendar quarter W Calendar week 24 Rev 2 Lower Limit of Detection (LLD)*

(µCi/ml) 5 x 10-1 1 x 10-6 1 X 10-S 1 x io-s 1 x 10"7 5 x 10-8

5. x 10-1 1 x 10-6 1 X 10-S 1 x 10-s 1 x 10-1 5 X lQ-S 01/05/%

Table D-1 (Cont'd)

TABLE NOTATION 8The LLD is defined, in Table E-3, Note C.

bA batch release is the discharge of liquid wastes of a discrete volume_.

Prior to sampling for analyses, each batch shall be isolated and then thoroughly mixed

"':"-:; essure representative sampU.ng.

c-rhe principal gamma emitters for which the LLD specification applies exclusively are the following radionuclides: *Mn-54, Fe-59, Co-58, Co-60, Zn-65, Mo-99*,

Cs-134, Cs-137, Ce-141, and Ce-144*.

This list does not mean that only these nuclides are to be considered. Other gamma peaks that are identifiable, together with those of the above nuclides, shall also be analyzed and reported in the Radioactive Effluent Release Report.

  • fLLD - 5rn-06 because of low gamma yield~°**

dA composite sample is one in which the quantity of liquid sampled is proportional to the quantity of liquid waste discharged and in which the method of sampling employed results in a specimen that is representative of the liquids released.

cA continuous release is the discharge of liquid wastes of a nondiscrete volume; I

eg, from a volume of a system that has an input flow during the continuous release.

fTo be rept:esentative of the quantities and concentrations of radioactive materials in liquid effluents, samples shall be collected in a series of aliquots of constant volume collected at regular time intervals and combined to form a single sample.

Prior to analyses, all samples taken for the composite shall be thoroughly mixed in order for the composite sample to be representative of the effluent release.

25 Rev 2 01/05/94

--~-

H.

/.

Liquid Effluent Dose

1.

Requirement:

The dose or dose commitment to a Member of the P *blic from radioactive materials in liquid effluents released from each reactor unit to Unrestricted Areas shall be limited:

--a_--;------

  • cf1.1-*i1.tg *c111y* calendar quarter. to less tha11....... -i. **.

mrems to the total body and to less than or equal to 5 mrems to any organ, and

b.

during any calendar year to less than or equal to 3 mrems to the total body and to less than or equal to 10 mrems to any.organ.

2.

Action:

With the calculated dose from the release of radioactive materials in liquid effluents exceeding any of the-_ above limits, prepare and submit to the NRG within 30 days a Special Report that identifies the cause(s) for exceeding the limit(s) and defines* the corrective actions that have been taken to reduce the releases and the proposed corrective actions to be taken to assure that subsequent releases will be in compliance with the above limits. This Special Report shall also include the results of radiological analyses of the dririking water source.

3.

Surveillance Requirements:

4.

Cumulative* dose contributions from liquid effluents for the current calendar quarter and the current calendar year shall be determined in accordance with the methodology and parameters in the ODCM at least once every 31 days.

Bases:

This requirement is provided to implement the requirements of Sections II.A, III.A, and IV.A of Appendix I, 10CFR Part 50.

The Limiting Condition for Operation implements the guides set forth in Section II.A of Appendix I.

The Action statements provide the required operating flexibility and at the same time implement the guides set forth in Section IV.A of Appendix I to assure that the releases of radioactive material in liquid effluents to Unrestricted Areas will be kept "as low as is reasonably achievable." Also, for freshwater sites with drinking water supplies that can be potentially affected by Plant operations, there is reasonable assurance that the operation of the facility will not result in radionuclide 26 Rev 2 01/05/94

concentrations in the finished drinking water that are in

. excess of the requirements of 40CFR Part 141.

The dose calculation methodology and parameters in the ODCM implement the requirements in Section-III.A of Appendix I

that conformance with the guides of Appendix I be shown by calculational procedures based on models and data, such that the actual exposure of a Member of the Public through appropriate pathways is unlikely to be substantially underestimated.

The *equations :.rJS;...i.. ~- ~-**d L.i i.:he.ODCM for calculating the doses due to the actual release rates of radioactive materials in liquid effluents are consistent with the methodology provided in Regulatory Guide 1.109,

°Calculation of Annual Doses to Man From Routine Releases of Reactor Effluents for the Purpose of Evaluating Compliance with 10CFR Part 50, Appendix I," Revision 1, October 1977 and Regulatory Guide 1.113, "Estimating Aquatic Dispersion of Effluents From Accidental and Routine Reactor Releases for the Purpose of Implementing* Appendix I," April 1977.

I.

Total Dose

1.

Requirement:

(

The annual (calendar year) dose or dose commitment to any Member of the Public due to releases of radioactivity and to radiation from uranium fuel cycle sources shall be limited to less than or equal to 25 mrems to the total body or any organ, except the thyroid, which shall be limited to less than or equal to 75 mrems.

2.

Action:

With the calculated doses from the release of radioactive materials in liquid or.gaseous effluents exceeding twice the limits of III.C.1.a, III.C.1.b, III.D.l.a, III.D.1.b, III.H.1.a, or III.H.l.b, calculations should be made including direct radiation contributions from the reactor units and from outside storage tanks to determine whether the above limits of III. I.1 have been exceeded. If such is the case, prepare and submit to the NRC within 30 days a Special Report that defines the corrective' action to be taken to reduce subsequent releases to prevent recurrence of exceeding the above limits and includes the schedule for achieving conformance with the above limits.

This Special Report, as defined in 10CFR Part 20.2203, shall include an analysis that estimates the radiation exposure (dose) to a Member of the Public from uranium fuel cycle sources, including all effluent pathways and direct radiation, for the calendar year that includes the release(s) covered by this report.

It shall also describe levels of radiation and concentrations of radioactive material 27 Rev 2 01/05/94

3.
4.

involved and the cause of the exposure levels or

. concentrations.

If the estimated dose(s) exceeds the above.

limits, and if the release condition resulting in violation of 40CFR Part 190 has not already been corrected, the Special Report shall include a request for a variance in accordance with the provisions of 40CFR Part 190.

Submittal of the report is considered a timely request and a variance is granted until staff action on the request is complete.

Surveillance Requirements:

a.

Cumulative dose contributions from liquid and gaseous effluents shall be determined in accordance with III.C.l, III.D.l and III.H.l and in accordance with the methodology and parameters in the ODCM.

b.

Cumulative dose contributions from direct radiation from the reactor.units* and from radwaste storage tanks shall be determined in accordance with the methodology and parameters in the ODCM.

This requirement is applicable only under conditions set forth in Action I.2 above.

Bases:

This requirement is provided to meet the dose limitations of 40CFR Part 190 that have been incorporated into 10CFR Part 20 by 46 FR 18525.

It also requires the preparation and submittal of a Special Report whenever the calculated doses from Plant generated radioactive effluents and direct radiation exceed 25 mrems to the total body or any organ, except for thyroid, which shall be limited to less than or equal to 75 mrems.

For sites containing up to 4 reactors, it is highly unlikely that the resultant dose to a Member of the Public will exceed* the. dose limits of 40CFR Part 190 if the individual reactors remain within twice the dose design objectives of Appendix I and if direct radiation doses from the reactor units and outside storage tanks are kept small.

The Special Report will describe a course of action that should result in the limitation of the annual dose to a Member of the Public to within the 40CFR Part 190 limi~s.

For the purposes of the Special Report, it may be assumed that the dose commitment to the Member of the Public from other uranium fuel cycle sources is negligible, with the exception that dose contributions from other nuclear fuel cycle facilities at the same site or within a radius of 8 km must be considered. If the dose to any Member of the Public is estimated to exceed the requirements of 40CFR Part 190, the Special Report with a request for a variance (provided the release conditions resulting in violation of 40CFR Part 190 have not already been corrected),

in accordance with the provisions of 28 Rev 2 01/05/94

40CFR Part 190.11 and.10CFR Part 20.2203, is considered to be

. a timely request and fulfills the requirements of 40CFR Part 190 until NRC staff action is completed.

The variance only relates to the limits of 40CFR Par~ 190 and does not apply in any way to the other requirements for dose limitation of 10CFR Part 20.

An individual is not considered a Member of the Public during any period in which he/she is engaged in carrying out any operation that is part of the ntll..:.l.c<C.i "i.J.d*: --11..:l.t:! *.

J.

Radiological Environmental Monitoring

1.

Requirement:

The radiological* environmental monitoring program shall be.

conducted as specified in Table E-1.

2.

Action:

a.

With the radiological environmental monitoring program not being conducted as specified in Table E-1, prepare and submit to the NRC, in the Annual Radiological Environmental Operating Report a description of the reasons for not conducting the program as required and the plans for preventing a recurrence.

b.

With the level of radioactivity as the result of Plant effluents in an environmental sampling medium at a specified location exceeding the reporting levels of Table E-2 when averaged over any calendar quarter, prepare and submit to the NRC within 30 days a Special Report that identifies the cause(s) for exceeding the limit(s) and defines the corrective actions to be taken to reduce radioactive effluents. When more than one of the radionuclides in Table E-2 are detected in the sampling medium, this report shall be submitted if:

Concentration (1)

Reporting Level (1)

+

Concentration (2) +.... ~ 1. 0

,~eporting Level (2)

When radionuclides other than those in Table E-2 are detected and are the result of Plant effluents, this report shall be submitted if the potential annual dose to a Member of the Public is equal to or greater than the calendar year limits of III. C.1, III. D.1, and III.H.l.

This report is not required if the measured level of radioactivity was not the result of Plant effluents; however, in such an event, the condition shall be reported and described in the Annual

  • Radiological Environmental Operating Report.

29 Rev 2 01/05/94

c.

'!'=---

With milk or fresh leafy vegetable samples unavailable from one or more of the sample locations required by Table E-1, identify locations for obtaining replacement samples and add them to the radiological environmental monitoring program within 30. days.

The specific locations from which samples were unavailable may then be deleted from the monitoring.program.

Identify the cause of. the unavailability of samples and identify the

  • uew location(s) for. obtainiiLC, *-. :.,.. * - ~i'::UUflles in the next Annual Radiological*Environmental Report.
3.

Surveillance Requirements:

a.

The radiological environmental monitoring samples shall be collected pursuant to Table E-1 and shall be analyzed pursuant to the requirements of Table E-1 and the detection capabilities required by Table E-3.

b.

A land use census shall be conducted and shall identify within a distance of 8 km (5 miles) the location in each of the 9 overland meteorological sectors of the nearest milk animal, the nearest residence and the nearest garden of greater than 50 ui2- (500 ft2) producing broad leaf vegetation.

Broad leaf vegetation sampling of at least three different kinds of vegetation may be performed at the site boundary in each of two different direction sectors with the highest predicted D/Qs in lieu of the garden census.

For broad leaf vegetation

sampling, Table E-1, item 4c, shall be followed, including analysis of control samples.
c.

The land use census shall be conducted during the growing season at least once per 12 months using that information that will provide the best results, such as by a

door-to-door

survey, aerial
survey, or by consulting local agriculture authorities.

The results of the land use census shall be included in the Annual Radiological Environmental Operating Report and shall be included in a revision of the ODCM for use in the following calendar year.

d.

Analyses shall be performed on radioactive materials supplied as part of an Interlaboratory Comparison Program that has been approved by the NRC.

e.

A summary of the results obtained as part of the above required Interlaboratory Comparison Program shall be included in the Annual Radiological Environmental Operating Report.

30 Rev 2 01/05/94

f.
4.

Bases:

The environmental air samplers shall be operationally checked monthly and airflow verified annually.

a.

Monitoring Program The radiological environmental monitoring program provides representati Vt? measurements of radiation and of radioactive materials in those exposure pathways and for those radionuclides that lead to the highest potential radiation exposures of Members of the Public resulting from the station operation.

This monitoring program implementsSection IV. B. 2 of Appendix I to 10CFR Part SO and thereby supplements the radiological effluent monitoring program by verifying that the measurable concentrations of radioactive materials and levels of radiation are not*higher than expected on the basis of the effluent measurements and the modeling of the environmental exposure pathways.

Guidance for this monitoring program is provided by the Radiological Assessment Branch Technical Position on Environmental Monitoring. The initially specified monitoring program will be effective for at least the first three years of commercial operation.

Following this period, program changes may be initiated based on operational experience.

The required detection capabilities for environmental sample analyses are tabulated in terms of the lower limits of detection (LLDs).

The LLDs required by Table E-3 are considered optimum for routine environmental measur.ements in industrial laboratories.

Detailed discussion of the LLD, and other detection limits, can be found in HASL Procedures Manual, HASL-300 (revised annually), Currie, LA, "Limits for Qualitative Detection and Quantitative Determination - Application to Radiochemistry," Anal Chem 40, 586-92 (1968), and Hartwell, J K, "Detection Limits for Radioanalytical Counting Techniques, " Atlantic Richfield Hanford Company.

Report ARH-SA-215 (June 1975).

b.

Land Use Census:

This requirement is provided to ensure that changes in the use of areas at and beyond the site boundary are identified and that modifications to the radiological environmental moni taring program are made if required by results of this census.

The best information from the 31 Rev.2 01/05/94

~ ------

c.

door-to-door

survey, from aerial survey or from consulting with local agricultural authorities shall be used.

This census satisfies the requirements of Section IV.B.3 of Appendix I

to 10CFR Part

50.

Restricting the census to gardens of greater than 40 m2 provides assurance that significant exposure pathways via leafy vegetables will be identified and monitored since a garden of this size is the minimum required to

-- -iJtoduce the quantity (16 kg/yr)* of led.[j <.eg.. t db:..:;s assumed in Regulatory Guide 1.109 for consumption by a child.

To determine this minimum garden size, the following assumptions were made:

(1) 20% of the garden was used for growing broad leaf vegetation (ie, similar to lettuce and cabbage), and (2) a vegetation yield of 2 kg/m2.

Interlaboratory Comparison Program:

The requirement for participation in an approved Interlaboratory Comparison Program is provided to ensure that independent checks on the precision and accuracy of the measurements of radioactive material in environmental sample matrices are performed as part of the

,quality assurance program for environmental monit.oring in order to demonstrate that the results are valid for the purposes of Section IV.B.2 of Appendix I to 10CFR Part 50.

32 Rev 2 01/05/94

Exposure Pathway and/or Sample

1.

DIRECT RADIATH :lb

'.f Table E-1 Ra,QlOLOGICAL ENVIRONMENTAL MQNlIORING PROGRAM Number of Representative Samples and Sample Locationsa 21 routine monitoring stations either with two or more dosimeters or with one instrument for measuring and recording dose rate continuously, placed as follows:

An inner ring of stations, one in each overland meteorological sector (9) in the general area of the Site Boundary.

An outer ring of stations, one in each overland meteorological sector (9) within the* 12 km range from the site..

The balance of the stations (3) to be placed to serve as control stations.

33 Sampling and Collection Frequency Quarterly Type of Frequency of Analysis Gamma dose quarterly Rev 2 01/05/94

Exposure Pathway and/or Sample

2.

AIRBORNE Radioiodine and Particulates Table E-1 (cont'd)

RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM Number of Representative Samples and Sample Locationsa Samples from 5 locations.

3 samples from within 6 km of the Site Boundary in different sectors (2.4 km-SSW, 5.6 km-ESE, and 1. 6 km-N).

1 sample from the vicinity of a community having the highest calculated annual average ground level D/Q (Covert-5:6 km-SE).

1 sample from a control location in the least prevalent wind direction° (Grand Rapids 89 km-NNE).

34 Sampling and Collection Frequency Continuous sampler operation with sample collection weekly or more frequently if required by dust loading.

Type of Frequency of Analysis Radioiodine Canister:

I-131 analysis weekly for

. each filter change.

Particulate Sampler:

Gross beta radioactivity analysis following filter changed.

Gamma isotopic analysise if gross beta

>l. 0 pCi/m3.

Rev 2 01/05/94

Exposure Pathway and/or Sample 3.

WATERBORNE

a.

Lake (surface)

b.

Well (drinking)

c.

Lake (drink~ng)

d.

Sediment fr.Jrn shoreline Table E-1 (cont'd)

RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM Number of Representative Samples and Sample Locationsa Plant lake water inlet.

Samples from Flant, State Park, and Covert Township park wells..

1 sample of South Haven drinking water supply.

1 sample from between north boundary and Van Buren State Park beach.

35 Sampling and Collection Frequency Composite* sample over 1-month periodr.

Monthly - grab sample.

Composite sample over 1-month periodr.

Semiannually.

Type of Frequency of Analysis Gross beta (>10 pCi/l requires gamma) and tritium monthly.

Gross beta (>10 pci/1 requires gamma) and tritium monthly.

Gross beta (>10 pCi/l requires gamma) and tritium monthly.

Gamma isotopic analysise semiannually.

Rev 2 01/05/94

Exposure Pathway and/or Sample

4.

INGESTION

a.

Milk

. b.

Fish and Invertebrates Table E-1 (cont'd)

RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM Number of Representative Sam es and Sa le Locat ons8 Samples from milking animals in 3 locations between 5-13 km distance.

1 sample from milking animals at a control location, 15-30 km distance.

Sample 2 species of commercially and/or recreationally important species in vicinity of Plant discharge area.

1 sample of same species in areas not influenced by Plant discharge.

36 Sampling and Co Monthly.

Sample in season or semiannually if they are not seasonal.

Type of Frequency 0

s s Gamma isotopice and I-131 analysis monthly.

Gamma -isotopic analysise on edible portions..

Rev 2 01/05/94

'I Exposure Pathway and/or Sample

c.

Food Products Table E-1 (cont'd)

RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM Number of Representative Samples and Sample Locations8 1 sample each of two principal fruit crops (blueberries and apples).

Samples of 3 different kinds of broad leaf vegetation grown nearest each of two different offsite locations of highest

  • predicted annual average ground level D/Q if milk sample is not performed.

(SE or SSE sectors near site).

1 sample of each of the similar broad leaf vegetation grown 15-30 km distance in the least prevalent wind direction if milk sampling is not performed.

(SSW or S sectors).

37 Sampling and Collection Frequency At.time of harvestg.

Monthly when available.

Monthly when available.

Type of Frequency of Analysis Gamma isotopic analysese on edible portion.

Gamma isotopice and I-131 analysis.

Gamma isotopice and I-131 analysis.

Rev 2 01/05/94

4.

INGESTION

a.

Milk

b.

Fish and Invertebrates

' \\

PALISADES NUCLEAR PLANT OFFSITE DOSE CALCULATION MANUAL TITLE: RELOCATED TECHNICAL SPECIFICATIONS PER NRC GENERIC LETTER 89-01 CTAC NO 75060)

Samples from milking animals in 3 locations between 5-13 km distance.

Monthly 1 sample from milking animals at a control location. 15-30 km distance.

Sample 2 species of commercially and/or Sample in season or recreationally important species in vicinity semiannually if they of Plant discharge area. 1 samgle of same are not seasonal.

species in areas not influence y Plant discharge..

At time of harvest9.

1 samgle each of two principal fruit crops (blue erries and apples).

Samples of 3 different kinds of broad leaf Monthly when vegetation grown nearest each of two available.

different offsite locations of highest predicted annual average ground level D/Q if milk sample is not performed.

(SE or SSE sectors near site).

1 sample of each of the similar broad leaf Monthly when vegetation grown 15-30 km distance in the available.

least prevalent wind direction if milk sampling is not performed.

(SSW or S sectors).

Proc No ODCM Appendix A Revision 3 Page 38 of 55 Gamma isotopice and I-131 analysis monthly.

Gamma isotopic analysise on edible portions.

I f '\\

I l f \\I

~ "d Garn a 1i ~o,t pi ce /and*

Icl 1 \\allysi s.\\*./.

.*I i

i Gqn:iTia I~ s. toJ~ ce Jarid \\

I*f31a:nr1y~*1s.

'*-. ~ I

Table E-1 (cont'd)

Table Notation aDeviations are pen1itted from the required sampling schedule if specimens are unobtainable due to hazardous conditions, seasona**. unavailability, malfunction of automatic sampling equipment and other legitimate reasons.

If specimens are unobt ~.nable due to sampling equipment malfunction, every effort shall be made to complete corrective action prior to the end of the next sampling period. All deviations from the sampling schedule shall be documented in the Annual Radio~~ogical Environmental Operating Report. It is recognized that, at times, it may not be possible or practicable to c~ntinue to obtain samples of the media of choice at the most desired location or time.

In these instances, suitabl~ alternative media and locations may be chosen for the particular pathway in question and appropriate substitutions made within 30 days in the radiological environmental monitoring program.

hone or more instruments, such as a pressuriz~d ion chamber, for measuring and recording dose rate continuously may be used in place, or in addition to, integrating dosimeters.

For the purposes of this table, a thermoluminescent dosimeter (TLD) is considered to be one phosphor; two or more phosphors or phosphor readout zones in a packet are considered as two or more dosimeters.

<>fhe purpose of this* sample is to obtain background information.

If it is not practical to establish control locations in accordance with the distance and wind direction criteria, other sites that provide valid background data may be substituted.*

dAirborne particulate sample filters shall be analyzed for gross beta radioactivity 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> or more after sampling to allow for radon and thoron daughter decay. If gross beta activity in air particulate samples is greater than ten times the yearly mean of _control samples, gamma isotopic analysis shall be performed on the individual samples.

eGamma isotopic anc.lysis means the identification and quantification of gamma-emitting radionuclides that may be attributable to the effluents from the facility.

fA composite sample is one in which the quantity (aliquot) of liquid samples is proportional to the quantity of liquid discharged and. in v.*hich the method of sampling employed results in a specimen that ls representative of the liquid released (continuo\\~s composites or daily grab composites which meet this crit~ria are acceptable).

glf harvest occurs more than once a year, sampling shall be performed during each discrete harvest.

38 Rev 2 01/05/94

Table E-2 REPORTING LEVELS FOR RADIOACTIVITY CONCENTRATIONS IN ENVIRONMENTAL SAMPLES Reporting Levels Water Airborne Particulates Fish Milk Food Products Analysis

(:gCiLl) or Gases (:QCiLm3 }

(:gCiLkg, Wet)

(gCiLll (gCiLkg, Wet)

H-3 20,000*

Mn-54 1,000 30,0QO Fe-59 400 10,000 Co-58 1,000 30,000 Co-60 300 10,000 Zn-65 300 20,000 Zr-Nb-95 400 I-131 2

0.9 3

100 Cs-134 30 10 1,000 60 1,000 Cs-137 50 20 2,000.

70 2,000 Ba-La-140 200 300

  • For drinking water samples.

This is 40CFR Part 141 value. If no drinking water pathway exists, a valu~ of 30,000 pCi/l may be used.

39 Rev 2 01/05/94

Water Anal:;i:sis

{yCi£'.ll Gross Beta 4

H-3 2,000*

Mn-54 15 Fe-59 30 Co-58, 60 15 Zn-65 30 Zr-Nb-95 15 I-131 ld Cs-134 **

15 Cs-137 16 Ba-La-140 15 Table E-3 DETECTION CAPABILITIES FOR ENVIRONMENTAL SAMPLE ANALYSIS8 LOWER LIMIT OF DETECTION (LLD)bc Airborne Particulates Fish Milk Food Products or* Gases (I!Ci£'.m3 )

{RCi£'.kg, Wet)

{yC;J.Lll (gCi,/kg, Het) 0.01 130 260 130 260 0.07 1

60 0.05 130 15 60 0.06 150 16 60 15

  • If no drinking water pathway exists, a value of 3,000pCi/l may be used.

40 Rev 2 Sediment

(:QC1£'.kg, Dt::;i:)

150 160 01/05/94

Table E-3 (Cont'd)

TABLE NOTATION a This list does not mean that only these nuclides are'to be considered.

Other peaks that are identifiable, together with those of the above nuclides, shall also be analyzed and reported in the Annual Radiological Environmental Operating Report.

hRequired detection capabilities for thermoluminescent dosimeters used for environmental measurements are given in Regulatory Guide 4.13.

~e LLD is defined as the smallest concentration of radioactive material in a sample that will yield a net count, above system background, that will be detected with 95% probability with only 5% probability of falsely concluding that a blank observation represents a "real" signal.

For a particular measurement system, which ~ay include radiochemical separation:

LLD =

E

  • V
  • 2. 2 2
  • Y
  • Exp ( - >.t:. t)

Where:

LLD is the "a priori" lower limit of detection as defined above, as picocuries per unit mass or volume.

sb is the standard deviation of the background counting rate or of the counting rate of a blank sample as appropriate, as counts per minute.

E is the counting efficiency, as counts per disintegration.

V is the s~ple size in units of mass or volume.

2.22 is the number of disi~tegrations per minute per picocurie.

Y is the fractional radiochemical yield, when applicable.

>. is the radioactive decay constant for the particular radionuclide.

t:.t for environmental samples is the elapsed time between sample collection, or end of the sample collection period, and time of counting.

Typical values of E, V, Y, and t:.t should be used in the calculation.

41 Rev 2 01/05/94

Table E-3 (Cont'd)

TABLE NOTATION It should be recognized that the LLD is defined as an "a priori" (before the fact) limit representing the capability of a measurement system and not as an "a posteriori" (after the fact) limit for a particular measurement. Analyses shall be performed in such a manner that the stated LLDs will be achieved under routine conditions.

Occasionally background fluctuations, unavoidable small sample*

si.~es, thP.

presence of interfering

nuclides, or other uncontrollable circumstances may render these LLDs unachievable.

In such cases, the contributing factors shall be identified and described in the Annual Radiological Environmental Operating Report.

dLLD for drinking water samples.

If no drinking water pathway exists, the LLD of gamma isotopic analysis may be used.

42 Rev 2 01/05/94

  • K.

SIRW or Temporary Liquid Storage Tank

1.

Requirement:

The concentration of radioactive material contained in the SIRW tank or any unprotected outside temporary tank* shall be limited such that the mixture radionuclides do not exceed 1,000 times the effluent concentration (EC) as listed in 10CFR Part 20, Append..L.X. :0, 'fable 2, Column 2.

<1000

2.

Action:

3.
4.

With the quantity of radioactive material in any of the above listed tanks exceeding the above concentration, immediately suspend all additions of radioactive material to the tank, within 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> reduce the tank contents to within the limit, and describe the events leading to this condition in the next Radiological Effluent Release Report.

Surveillance Requirement:

The concentration of radioactive material contained in each of the above listed tanks shall be determined to be within the ab~ve limit by analyzing a representative sample of the tank's contents at least once per 7 days when radioactive materials are being added to the tank.

Bases:

This requirement will provide reasonable assurance that in the event of an uncontrolled release of the tanks' contents, the resulting concentrations would be less than the limits of 10CFR Part 20, Appendix B, Table 2, Column 2, at the nearest potable water supply and the nearest surface water supply in an Unrestricted Area.

(The dilution between Palisades and the South Haven drinking water supply has been established as 1000).

  • Tanks included in this specification are those outdoor tanks that are not surrounded by liners, dikes, or walls capable of holding the tank contents and that do not have tank overflows and surrounding area drains connected to the liquid radwaste treatment system.

43 Rev 2 01/05/94

~~rt&ftlttHl§~::q~~if.~jWti.~::::::;nw~?':ti~~eii irn i!li~1i:;mn11t

.\\

44 Rev 3 1-1-95

  • IV.

REPORTING REQUIREMENTS A.

Radiological Effluent Release Report The Radioactive Effluent Release Report shall be submitted in accordance with 10CFR 50. 36a ~ltM!#:§lW~ilfa'g\\Y.Jm!~§Jf:~!!I*

The report shall include a summary of the quantities of radioactive liquid and gaseous effluents and solid waste released from the unit.

The material provid~d shall be (1)

<..:v11:s~&i.:c11\\:.. with the objectives outlined in the ODCM and Process Control Program and (2) in conformance with 10CFR 50.36a and Section IV.B.l of Appendix I to 10CFR 50.

The report shall include an estimate of the uncertainty associated with the measurement of radioactive effluents.

This error term is included to provide an estimate of the uncertainty and is ~

to be considered the absolute error associated with the measurem~nts or to be used in determining compliance with these requirements.

These estimates will be based on a statistical analysis of a series of sample results (weighed appropriately for counting sta:tistics) taken once a year from a minimum of one typical gaseous waste tank and from a minimum of one typical liquid waste tank.

For noble gases released to the atmosphere from other than the waste gas system the error term will be estimated (and weight-averaged with the waste gas tank error) based on a statistical analysis of a series of sample results taken once a year (or the stack gas monitor counting statistics taken over one release per year) from each source contributing more than 10% of the total annual release.

The error atmosphere gas sample term for iodine and particulates released to the will be based on the counting statistics for one stack taken during the year.

The report shall include an estimate of the lower level of detection (in µCi/ml) if the unidentified portion of the release exceeds 10%

of the total annual releases.

This estimate of the lower level of detection will be made for those gamma emitting isotopes listed in Appendix B of Regulatory Guide 1.21(June1974) and will be provided based on a typical background gamma spectruII!.

The report sball provide the following specific terms:

1.

Supplemental Information

a.

Batch Releases:

The report should provide information relating to batch releases of liquid and gaseous effluents which are discharged to the environment.

This information should 45 Rev 3 1-1-95

include the number of releases, total time period for

.~

batch releases, and the maximum, mean, and minimum time period of release.

b.

Abnormal Releases The number of abnormal releases.of radioactive material to the environment should be reported. The total curies of *r1fdi.oact..L"Ve Wl:lcerials released as a

result; abnormal releases should be included.

2.

Gaseous Effluents

a.

Gases

1)

Total curies of fission and activation gases releases.

2)
3)
4)

Average release rates activation gases for covered by the report.

Percent of limit for activation gases.

(µCi/s) of fission and the quarterly periods releases of fission and Quarterly sums of total curies for each of the radionuclides determined to be released, based on analyses of fission and activation gases.

b.

Iodines

1)

Total curies of each of the isotopes, Iodine-131, Iodine-133 and Iodine-135 determined to be released..

2)

Average release rate (µCi/s) of Iodine-131/133.

3)

Percent of limit for Iodine-131/133.

c.

Particulates

1)

Total curies of radioactive particulate form with half-lives 8 days determined to be released.

material in greater than

2)

Average r~lease rate

(µCi/s) of radioactive material in particulate form with half-lives greater than 8 days.

46 Rev 2 01/05/94 *

3)

Percent of limit for radioactive material in particulate form with half-lives greater *than 8 days.

4)

Total curies for each of the radionuclides in particulate form determined to be released based on analyses performed.

j)

Total curies.. of* gross c..::..t':.~. :.. - **!c<.**"'..-; :-.~l~y determined to be "released.

d.

Tritium

1)

Total curies of tritium determined to be released in gaseous effluents.*

2)

Average release rate (µCi/s) of tritium.

3)

Percent of applicable limits for tritium.

3.

Liquid Effluents

a.

Mixed Fission and Activation Products

1)

Total curies of radioactive material determined to be released in liquid effluents (not including tritium, dissolved and/or entrained gases, and alpha-emitti~g material).

2)

Average concentrations (µCi/ml) of mixed fission and activation products released to unrestricted

areas, averaged over the quarterly periods covered by the report.
3)

Percent of applicable limit of average concentrations released to unrestricted areas.

4)

Quarterly sums of total curies for each of the radionuclides,determined to be released in liquid effluents based on analyses performed.

b.

Tritium

1)

Total curies of tritium determined to be released in liquid effluents.

2)

Average concentrations

(µCi/ml) of tritium released in liquid effluents to unrestricted

areas, averaged over the quarterly periods covered by the report.

47 Rev 2 01/05/94

3)

Percent of applicable limit of average concentrations released to unrestricted areas.

c.

Dissolved and/or Entrained Gases

d.
e.
1)

Total curies of gaseous radioactive material determined to be released. in liquid effluents.

Z)

3)
4)

Alpha Average cpncentJ.:c:i.* ;.-._.

/ *.. ~,

uf d,issolved and/or entrained gaseous radioactive material released to unrestricted areas,. averaged over the quarterly periods covered by the report.

Percent of applicable limit of average concentrations released to unrestricted areas.

Total curies for each of the radionuclides determined to be released as dissolved and/or entrained gases in liquid effluents.

Radioactivity Total curies of gross alpha-emitting material determined to be released in liquid effluents.

Volumes

1)

Total measured volume (liters),

prior dilution, of liquid effluent released.

to

2)

Total determined volume, in liters, of dilution water used during the period of the report.

4.

Radiological Impact on.Man:

The Radioactive Effluent Release Report shall include potential doses to individuals and populations calculated using measured effluent and averaged meteorological data in accordance with the methodologies in the ODCM.

a.

Total body and significant organ doses (greater than 1 millirem to individuals in unrestricted areas from receiving water-related exposure pathways.

b.

The maximum offsite air doses (greater than 1 millirad) due to beta and gamma radiation at locations near ground level from gaseous effluents.

48 Rev 2 01/05/94 e

B.

c.
d.

Organ doses (greater than 1 millirem) to individuals in unrestricted areas from radioactive iodine and radioac~ive material in particulate form from the major pathways of exposure.

Total body doses (greater than 1

manrem) to the population and average doses (greater than 1 millirem) to individuals in the population from receiving wate-r*..:l:'~:;_a.* -~

~~L-~L.. 1:J.j:. co* a distance of SO miles,.f.x,;,.c the site.

e.

Total body doses (greater than 1 manrem) to the population and average doses (greater than 1 millirem) to individuals in the population from gaseous effluents to a distance of SO miles from the site.

S.

ODCM Changes:

The Radiological Effluent Release Report shall include any changes made during the reporting period to the Offsite Dose Calculation Manual (ODCM),

as well as a listing of new locations for dose calculations and/or environmental monitoring identified by the land use census. pursuant to III.J.3.c.

Radiological Environmental Operating Report The Radiological Environmental Operating Report covering the operation of the unit during the previous calendar year shall be submitted before May 1 of each year.

The report shall include summaries, interpretations, and analysis of trends of the results of the Radiological Environmental Monitoring Program for the reporting period.

The material provided shall be consistent with the objectives outlined in; (1)

  • the ODCM, arid (2) Sections IV. B. 2, IV.B.3, and IV.C of Appendix 1 to 10CFRSO.

The Annual Radiological Environmental Operating Reports shall include summaries, interpretation and statistical evaluation of the results of the radiological environmental surveillance activities for the report period,* including a comparison with preoperational

studies, operational controls (as appropriate),

and previous environmental surveillance reports and* an assessment of the observed impacts of the Plant operation on the environment.

The reports shall also include the results of land use census pursuant to III.J:3.c.

49 Rev 2 01/0S/94

The Annual Radiological Environmental Operating Reports shall include summarized and tabulated results in the format of Table F-1 of all radiological environmental samples taken during the report period.

In the event that some results are not available for inclusion with the report, the report shall be submitted noting and explaining the reasons for the missing results.

The missing data shall be submitted as soon as possible in a* supplementary report.

The repo"rts shaJ:.l *also* include the following; a SUIDllliii.iy.-*'..:;;,'.,;.~-'.<'*:.*.'-*~

of the radiological environmental monitoring program, including sampling methods for each sample type, a map of all sampling locations keyed to a table giving distances and directions from the reactor and the results of land use census required by III.J.3.c and results of the Interlaboratory Comparison Program required by III.J.3.e.

C.

Nonroutine Reports A report shall be submitted to the NRG in the event that; 1) the Radiological Environmental Monitoring Programs are not substantially conducted as described in Section III.J, or 2) an unusual or important event occurs from Plant operation that causes a

significant environmental impact or affects a

potential environmental impact.

Reports shall be submitted within 30 days.

50 Rev 2 01/05/94

Medium or Pathway Sampled (Unit of Measure.)

Air Particulates (pCi/m3)

Table F-1 ENVIRONMENTAL RADIOLOGICAL !'DNITORING PROGRAM S~Y Name of Facility--------------

Docket No----------

Location of Facility ------------~Reporting Period--------~

(County, State)

Type/Total Lower Limit All Indicator Number er of Locations Control Locations Analyses Detection*

Hean (f)b Name Hean Cflb Hean(f)b Perform<--i (LLD)

Rangob.

Distance & Direction Rang ob Rangeb Grose fJ H6 0.003 0.08 (200/312)

Middletown 0.10(5/52) 0.08 (8/104)-

(0.05-2.0) 5 miles 340° (0.08-2.0)

(0. OS-1. 40)

,-Spec <2 Cs-137 0.003 0.05 (4/24)

Smithville 0.08 (2/4)

<LLD (0.03-0.13)

2. 5 miles 160° (0.03-0.13)

Ba-140 0.003 0.03 (2/24)

Podunk 0.05 (2/4) 0.02 (1/8)

(0.0l-0.08) 4 miles 210*

(0.01-0.08)

Sr-89 40 0.002

<LLD

<LLD Sr-90 40 0.0003

<LLD

<LLD 51 Number of REPORTABLE OCCURRENCES 1

4 l

0 0

Rev 2 01/05/94

Medium or Pathway SlllDpled (Unit of Hellllure.)

Fish pCi/kg (dry weight)

Type/Total Number of Analy11e11 Performed

-y-Spec 8 Cs-137 Co-60 Lower Limit of Detection*

(LLD) 80 80 80 Table F-1 (Cont'd)

All Indicetor

-Locations Hean (f)b Rangeb

<LLD

<LLD 120 (3/4)

(90-200)

NlllDe Distance & Direction River Hile 35 Podunk River

  • Nominal Lower Limit of Detection (l.LD) es defined in tablEl notation c of Table E-3.

<LLD

<LLD See Column 4 "Hean and range based upon detectab:.e measurements only.

Fraction of detectable measurement11 at specific locations

  • is indicated in parentheses (f).

dNote:

The ex11111Ple.data are provid~d for illustrative purposes only.

52 Control Locations Hean(f)b Rang ab 90 (1/4)

<LLD

<LLD Number of REPORTABLE OCCURRENCES 0

0 0

Rav 2 01/05/94

v.

MAJOR MODIFICATIONS TO RADIOACTIVE LIQUID AND GASEOUS W'ASTE TREATMENT SYSTEMS A.

Licensee Modifications B.

Licensee initiated major modifications to the radioactive liquid and gaseous waste systems.

1. *_. -*-shalJ.. li1:1 i~ported to the NRC pursuant to -lOCr~

.discussion.of each modification shall contain:

a.

A summary of the evaluation that led to the determination that the modification could be made in accordance with 10CFR Part 50.59.

b.

A description of the equipment, components and processes involved, and the interfaces with other Plant systems.

c.

Documentation of the fact that the modification was reviewed and found acceptable by the PRC.

2.

Shall become effective upon review and acceptance by the Plant General Manager.

Definition of Major Radwaste System Modification 1.

Purpose:

The purpose of this definition is to assure that this requirement will be satisfied under clearly identifiable circumstances, and with the objective that current radwaste system capabilities are not jeopardized.

2.

Definition:

A major radwaste system modification is a modification which would remove (either by bypassing for greater than 7 days or physical removal) or replace with less efficient equipment, any components of.the radwaste system:

a.

Letdown filters or demineralizers.

b.

Vacuum degassifier (not applicable when the reactor is in cold shutdown and depressurized).

c.

Miscellaneous or clean waste e~aporators.

d.

The present waste gas compressor/decay tank system.

e.

Fuel Pool filters/demineralizers.

53 Rev 2 01/05/94

f.
g.

-:a.;:

Radwaste polishing demineralizers.

Radwaste Solidification system..

Improvements or additions to improve efficiency will not be considered major modifications unless a complete substitution of equipment or systems is made with equipment of unrelated design.

Examples would be; 1) replacement of mechanical c!~o~#i;i." ~- *: :,_::,",.t;R steam, jet -

degassifier, 2) replacement of waste gas system with cryogenic

system,
3) replacement of asphalt solidification with cement system, and 4) change from deep bead resins to Powdex, etc.

54 Rev 2 01/05/94