ML18057B021

From kanterella
Jump to navigation Jump to search
Rev 14 to EM-09-02, Inservice Testing of Plant Valves, Reflecting Periodic Review to Include Mrn E-91-001 & E-91-002,consisting of Complete Rewrite of Procedure to Omit Vertical Lines
ML18057B021
Person / Time
Site: Palisades 
Issue date: 02/01/1991
From: Oroz R, Schrader G, Toner K
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
To:
Shared Package
ML18057B020 List:
References
EM-09-02-01, EM-9-2-1, NUDOCS 9107120201
Download: ML18057B021 (113)


Text

ATTACHMENT 2 Consumers Power Company Palisades Plant Docket 50-255 "INSERVICE TESTING OF PLANT VALVES" Procedure Number EM-09-02 Revision 14 June 28, 1991 110 Pages

~

. --<="-*1 PALISADES NUCLEAR PLANT ENGINEERING MANUAL PROCEDURE Revision and Approval Summary TITLE:

INSERVICE TESTING OF PLANT VALVES

1.

Prepared George E Schrader Responsible Individual

3.

Q-List ~ No Recommended Approval 01/09/91 Date

2.

QA Concurrence N/A per 10.42

4.

PRC Reviewed Proc No EM-09-02 Revision 14 Date Ol/30/91 Date "L

KAT oner 01/16/91 JAMeincke

~1/10/91

. Responsible Department Head Date

5.

Approved RDOroz

6.

Word Processing Incorporated

7.

Periodic Review Georqe::*~~LSchrader 01/16/91 Date 01/30/91 COY Date 02/01/90 Date Date Date Date Date Vertical lines havebeen omitted, this procedure is a complete rewrite.

PSL 90-1583 Date MRN E-91-001 E-91-002

1.0 2.0 3.0 4.0 PALISADES NUCLEAR PLANT

  • ENGINEERING MANUAL PROCEDURE TITLE:

INSERVICE TESTING OF PLANT VALVES PURPOSE SCOPE REFERENCES

  • Table of Contents DEFINITIONS AND RESPONSIBILITIES.

Proc No EM-09-02 Revhion 14 Page i

  • 1 1

1 4

5. 0 PROCEDURE 6

5.1 PROGRAM DESCRIPTION...........

6 5.1.4 Requirements for Relief Requests 6

5.2 VALVE TEST REQUIREMENTS...... *.. *.....

,7 5.2.1 Category A and B Exercise Testing CIWV-3400).

~7 5.2.2 Category C Safety and Relief Valve Testing.. *

ra
5. 2. 3 Category C Check Va 1 ve Testing
, 8 5.2.4 Category A Valve Leak Testing 10 5.2.5 Category D Valves *....... *..

11 5.2.6 Rapid Acting Valves *. *.

11 5.2.7 Motor Operated Valve Testing......

11 5.2.8 Remote Position Indication.. *

  • 11 5.2.9 Valve Testing SU11111ary..
  • 12 5.3 PROGRAM ADMINISTRATION 12
5. 3. 1 Test Procedures......

12 5.3.2 Scheduling.... *...

13 5.3.3 Modified Test Frequencies..

14 5.4 NON-CONFORMANCE/CORRECTIVE ACTIONS/DATA.. *...

14 5.4.6 Trending *...... * *.

16 5. 5 RECORDS. *...

16 6.0 ATTACHMENTS 17 ATTACHMENTS, "Valve Reference List in Alpha numeric Order" / "Valve Reference Fl ow Rates" Attachemnt 3, "Cold Shutdown Testing Basis", "Relief Request Basis"

TITLE:

PALI SADES.NUCLEA~ PLANT ENGINEERING MANUAL PROCEDURE INSERVICE TESTING OF PLANT VALVES Proc No EM-09-02 Revision 14 Page 1 of 17 1.0 PURPOSE I.I This procedure provides general requirements for the performance and administration of the Inservice Testing Program for ASME Class I, 2 and 3 valves.

I.2 This procedure establishes the requirements for the implementing procedures for inservice testing and evaluation of selected valves.

2.0 SCOPE 2.i This procedure complies with all requirements of Reference 3.5, ASME Boiler and Pressure Vessel Code,Section XI, Subsection IWV, I983, Addenda to Summer I983 with exception of the relief requests contained in Attachment 4.

2.2 The Palisades Plant Inservice Valve Testing Program will be in effect through the second I 20 month interval ( 1983 thru I 995) and wi 11 be updated in accordance with IOCFR50.55a (g).

2.3 3.0 3.1 3.2 3.3 3.4 3.5 3.6 3.7 3.8

,. provides a complete listing of those valves included in this program per the requirements of IWV-1100 and IWV-I 200, and specifies the frequency and the procedure to be used for each test.

These valves are those Class 1, 2, and 3 and other valves important to safety (and their actuating and position indicating systems), which are required to perform a specific function in shutting down the reactor to the cold shut down condition or in mitigating the consequence~ of an accident.

REFERENCES.

Technical Specifications Chapter 4-4.1.1, 4.0.2, 4.0.5, 4.3e, 4.3h, 4.3i, 4.3j, Table 4.3.1, 4.5.2, 4.6.3, 4.8 and 4.9 Final Safety Analysis Report 4.3.9, 6.9.2.2 10CFRS0.55(a)(g)(4) 10CFRSO, Appendix J

\\

ASME Boiler and Pressure Vessel Code,Section XI, Subsection IWV, I983 (S83)

NRC letter dated January I3, 1978 NRC Order dated April 20, I98I regarding Event V PIV's Generic Letter No 87-06, "Periodic Verification of Leak Tight Integrity of Pressure Isolation Valves"

    • -PALISADES~ NUCLEAR: PLANT ENGINEERING MANUALPROCEDURE Proc No EM-09-02 Revision 14 TITLE:

INSERVICE TESTING OF PLANT VALVES Page 2 of 17

  • 3.9 USNRC IE Bulletin No. 89-10, "Safety Related Motor Operated Valve Testing and Surveillance" dated 06/28/89 3.10 Generic Letter No 89-04, "Guidance on Developing Acceptable Inservice Testing Programs" (AIR A-NL-89-02A and PW04/03/89D) 3.11 Palisades Administrative Procedure 9.22, "Technical Specifications Surveillance Procedure Scheduling and Issue" 3.12 10CFR50.54(o) 3~13 NRC Information Notice 88-70, Check Valve* Inservice Testing Program deficiencies 3.14 CPCo Letter to NRC, Docket 50-255-License DPR-20, Palisades Plant, Confirmation of Conformance with Generic Letter 89-04, (TAC No. 747~3)

CRl:

"Control Room Log Sheet No. 1 11 3.15 3.16 3.17 EM-28-02:

"Preventative Maintenance Program for Check Valves" GOP-02:

"Plant Heatup (Cold *shutdown to Hot: Shutdown)"

3.18 GOP-13:

"Primary Side Leakage Calculation" 3.19 M0-38:

"Auxiliary Feedwater System

Pumps, Inservice Testing Procedure" 3.20 PPAC CCS028:

"Change Actuator Diaphragm on CV-0951" 3.21 PPAC eve 081:

"Replace Diaphragm on CV-2003, CV-2004, and CV-2005" 3.22 PPAC CVC 107:-."Preventative Maintenance of RV-2006" 3.23 M0-7A-l:

"Emerg~ncy Die$el Generator 1-1 (K-6A)"

3.24 MQ,;;,7A;;.2: "Emergency Diesel Generator 1-2 (K-68)"

--::-;:... -~.

3.25 PPAt.CVC UO:. "Preventative Maintenance of RV-2092"

3. 26 PPAC eve 111: _"Preventive Maintenance* of RV-2098'~r RV-2104"

\\

3.27 PPAC CVC 112: "Preventative Maintenance of RV-2090/2096/2102" 3.28 PPAC ESS133:

"Preventative Maintenance* to. inspect/repair/verify 3.29 3.30 setpoint of RV-3164" PPAC ESS134:

"Preventative Maintenance of RV-3162" PPAC ESS135:

"Preventative Maintenance of RV-3165."

3.31 PPAC ESS136:

"Preventative Maintenance of RV-3264"

TITLE:

PALI-SADES NUCLEAft':PLANT ENGINEERING MANUAL.PROCEDURE INSERVICE TESTING OF PLANT VALVES 3.32 PPAC ESS137:

"Preventative Maintenance of RV-3266" Proc No EM-09-02 Revision 14 Page 3 of 17 3.33 PPAC ESS138:

"Preventative Maintenance of RV-3128/RV-3143/RV-3158" 3.34 PPAC ESS139:

"Preventative Maintenance of RV-3267" 3.35 PPAC ESS141:

"PM of RV-0437 or RV-0438" 3.36 PPAC FWS-095: "Preventive Maintenance to Inspect/Repair/Verify Setpoint of RV-2092 11 3.37 PPAC OPS281:

"Verify Supplying Fire System to Service Water"

3. 38 PPAC OPS282:

"Verify CV-2001, CV-2113, CV-2115, CV-2111 11 3.39 PPAC OPS428:

"Stroke Test CV-0880 and CV-0879" 3.40 PPAC OPS440:

"Verify Manual Operation of Chemical Volume Control System MOV's" 3.41 Q0-01:

"Safety Injection System" 3.42 Q0-02:

"Recirculation Actuation System and Containment Sump Check Valves" 3.43 Q0-05:

"Valve Test Pro~edures (Includes Containment Isolation Valves)"

3.44 Q0-06:

"Cold Shutdown Valve Test Procedure (Includes Containment Isolation Valves)"

3.45 Q0-088:

"ESS Chee~ Valve Operability Test (Cold Shutdown)"

3.46 Q0-08C:

"ESS Check Valve Operability Test (Hot Shutdown)"

3.47 Q0-10:

"Containment Spray and LPSI Check Valve Test" 3.48 QO-ll:.

"Containment Isolation Check Valve Test" 3.49 Q0-13:

"Iodine Removal Valve Stroke Test!'

.~*

\\

3.50 Q0-14:

"Inservice Test Procedure -

S~rvice Wate~,Pumps" 3.51 Q0-15:

"Inservice Test Procedure - Component Cooli~g Water Pumps" 3.52 Q0-16:

"Inservice Test Procedure - Containment Spray Pumps" 3.53 3.54 Q0-17:

"Inservice Test Procedure - Charging Pumps"

\\

Q0-18:

"Inservice Test Procedure - Concentrated Boric Acid Pumps" 3.55 Q0-19: * "Inservice Test Procedure - HPSI Pumps"

i PALUAQES *NUClEAlf:PLANT ENGINEER-ING. MANUAL-~PROCEDURE Proc No EM-09-02 Revision 14 Page 4 of 17 TITLE:

INSERVICE TESTING OF PLANT VALVES 3.56 Q0-20:

"lnservice Test Procedure -

Low Pressure Safety Injection Pump" 3.57 Q0-21:

"Auxiliary Feedwater System Valves Inservice Test Procedure" 3.58 Q0-24:

"Verify Closure of Main Feedwater Check Valves" 3.59 Rl-115:

"Power Operated Relief Valves" 3.60 RM-29:

"Main Steam Safety Valve Setpoint Testing" 3.61 RT-41:

"Pressurizer Safety Valves RV-1039, RV-1040, and RV-1041" 3.62 RM-114:

"Disassembly, Verification of Disc Motion and Assembly of Safety Injection Tank 12 Inch Check Valves" 3.63 R0-32 Series:

"Local Leak Rate Test for Containment Penetrations",

3.64 R0-65:

"HPSl/RHPSI Check Valve Test" 3.65 R0-105:

"Full Flow Test for Safety Injection Bottle Check Valves CK-3102,

~K-3117, CK-3132, and CK-3147" 3.66 RT-88:

"Shutdown Cool ing/ESS Pump Suction Line Test" 3.67 RT-SSA:

"CV-3057 and CV-3031 Leak Test" 3.68 SH0-1:

"Operator's Shift Items" 3.69 S0-9:

"Primary Coolant System Pressure Isolation Check Valves" 3.70 S0-11:

"Verify Containment Purge and Ventilation Isolation Valves Closed"

3. 71 SOP-2A:

"Chemical and Volume Control System Charging and Letdown:

Concentrated Boric Acid" 4.0 DEFJftlTIONS AND RESPONSIBILITIES 4.1 Reference Value - a fixed set of valve operating parameters, (such as stroke time, leakage rate, etc.) whfch reflec:t acceptable valve operating characteristics and are determined froin the results of a baseline preoperational or inservice test.

They* shall be readily duplicated and subsequent inservice testing results shall be compared to these reference values.

4.2*

Safety Classification - The categorization of a valve as dependent upon its related system and safety related function.

The classifications

1983Property "ANSI code" (as page type) with input value "ANSI/ANS 51.1 -</br></br>1983" contains invalid characters or is incomplete and therefore can cause unexpected results during a query or annotation process.; 10CFR50.2V; 10CFR50.55a(g), Footnote 2; Reg. Guide 1.26.

TITLE:

PALISADES NUCLEAR !?LANT ENGlff.EER-ING MANUAL PROCEDURE INSERVICE* TESTING OF PLANT VALVES Proc No EM-09-02 Revision 14 Page 5 of 17 4.3 Valve Exercise Test - A test which exercises a valve to the position required for it to fulfill its necessary safety function.

4.4 Full-stroke - the exercising of a valve from full closed to full open using either an actuating signal or, as in the case of check valves, full system flowrate. Full-stroke flow rates for various check valves are listed in the "Valve Reference Flow Rate Table" maintained by the Inservice Inspection Section.

4.5 Partial Stroke - The exercising of a valve in the open direction just enough to verify disc movement off the seat. This is usually performed with check valves using lower than normal system flowrates.

4.6 Leakage Test - Verification by test of the leak tight integrity of a valve using differential air pressure or system fluid pressure.

4.7 Backflow Test - Verification of a check valve's closure ability upQn revers a 1 of norma 1 system fl ow.

4. 8 Stroke Time - The time interval from initiation of an actuating sign~l for a valve to open or close, to the end of the actuation cycle.

4.9 ISI Coordinator - responsible for the development and administration of the IST program for Plant valves. This person shall also evaluate test results and identify equipment deficiencies to the System Engineer.

4.10 System Engineer - Service manager for the system in question who is responsible for the maintenance and operating aspects of the tested equipment.

4.11 Technical Specifications Surveillance Program Administrator (TSSPA) -

res pons i bl e to oversee scheduling and admi ni strati ve performance of the required Technical Specifications Surveillance Test.

4.12 Relief Requests - Specific documents requesting exemption from code testing requirement, submitted to the U.S.

Nuclear Regulatory Conmt.ssion (NRC).

Upon identification of need, the initial request shall be submitted to the Nuclear Licensing Department who shall review the;r requests, ask appropriate questions, and prepare the request for relief~ for submittal to the NRC within 60 days of the identification of need.

Identification of need is defined as the point in time a Corrective-Action document (DR, ER, AIR, etc~) - is initiated or a revision to this procedure is begun.

4.13 Cold Shutdown Testing Basis -

Specific documents outlining the reason(s) specific equipment cannot be fully tested during power operations and outlining an alternative test program which meets the requirements of ASME Section XI and Generic Letter 89*04.

.~

5.0 5.1

5. I. I
5. I. 2 5.1.3 5.1.4
    • PAbJfSADES'.;.NtJCLEA£;PtANT

.ENGINEERING.MANUAL.PROCEDlfi!E Proc No EM-09-02 Revision 14 Page 6 of 17

~---*TITLE:

INSERVICE TESTIN6 OF PLANT VALVES PROCEDURE PROGRAM DESCRIPTION The Palisades Inservice Valve Test Program is summarized in the Attachment I. The valves were selected in accordance with ASME Boiler and Pressure Vessel Code,Section XI, Subsection IWV, 1983 583, and Generic Letter 89-04, "Guidance on Developing Acceptable Inservice Testing Programs". Each valve was assigned as Category A,B,C, or D, or combinations thereof.

They were also classified as Active or Passive in accordance with the definitions in ASME Section XI 1wv~2100.

Where testing is impractical, pursuant to 10CFR50.55a(g)(iii) and {iv),

and as required by Subsection IWV, specific relief shall be requested to perform a 1 ternate testing in 1 i eu of the* required test., "Relief Request Basis", contains valves meeting this condition.

i IWV-3412 and IWV-3522 requires the owner to specifically identily valves which cannot be full or part stroke tested during. normil operation and are* full-stroked dur'ing cold shutdown.,

"Cold Shutdown Test Basis", provides this information.

', -; i':

,)

Reauirements for Relief Requests

a. Relief Requests shall be submitted to the Nuclear Licensing Department upon identification of need. *-Th~ ~uclear Licensing Department sha 11 review the submittal' requests, *ask/ *'appropriate questions and prepare the requests for submittal t~ the United States Nuclear Regulatory Commission.
b. Relief Requ$st~ shall contain as a minimum the following elements:

I.

Reasons for the impracticality of the required testing.

~.. --

1t: ~~~e~~~~~~~~(~~ t~1 ~~tj~ff:.,rhn1que used and-a sunnnary of

_-;;:~}~~~c-0<" A' de~cription of the method and 'results of' the-program* lo

.. * -_ qualify the alternate techniqu~.for meeting the ASME Code.

/

\\:_,

4.

A.description of the instrumentation used\\and the maintenance and ca 1 i brat ion of the instruments.

    • \\' * * -- ' '
5.

A* description of the basis used to verffy the* 1>asel ine data has been generated when the component* -i-S known -to be in good

6.

work 1 ng order, and A description of the basis for the acceptance criteria for the alternate testing and a description of corrective actions to be taken if the acceptance criteria are not met.

TITLE:

PALfSADES NUCLEAR PLANT ENGINEERING MANUAL PROCEDURE INSERVICE TESTING OF PLANT VALVES 5.2 VALVE TEST REQUIREMENTS 5.2.1 Category A and B Exercise Testing CIWV-3400)

Proc No EM-09-02 Revisfon 14 Page 7 of 17

a.

Category A and B valves shall be exercised at least once every three months to the position required to fulfill their safety function unless such operation is not practical during Plant operation.

If only limited operation is practical during Plant operation, the valve shall be:

1.

Part-stroked during Plant operations, and

2.

Full-stroked during cold shutdowns.

b.

Valves that cannot be exercised during Plant operation shall be:

1.

Specifically identified in Attachment 3, and

2.

Full-stroke tested during cold shutdowns.

c.

Full-stroke exercising during cold shutdown for all valves not full-stroke tested during Plant operation shall be on a frequency determined by the intervals between shutdowns as follows:

1.

For intervals of three months or longer, exercise each cold

shutdown,
2.

For intervals of less than three months, full-stroke testing is not required unless three months have passed since the last shutdown test.

d.

For exercising:category A and B active valves, the necessary valve disk movement shall be determined by:

1.

Exercising the valve while observing an appropriate indicator which signals the required change of disk position, or Observing indirect evidence, such as changes in system pressure, flow rate, level or temperature, which reflect stem or disk position.

\\

\\

e. Stroke-time values for each power operated valve will be specified in the individual test procedure for the valve in question. Stroke times will be measured to the nearest second, for stroke times of 10 seconds or less, or 10% of the specified limiting stroke times for times greater than 10 seconds.
f. Reference stroke times and alert li~iting values for full-stroke times for testing purposes shall be determined as per Step 5.3.1.

PALISADES NUCLEAR-PLANT ENGINEEl{J~G llANUAl. PROCEDU.~E TITLE:

INSERVICE TESTING OF PLANT VALVES r

Proc No EM-09-02 Revision 14

  • Page 8 of 17 5.2.2 Category C Safety and Relief Valve Testing 5.2.3
a. Category C Safety and Relief Valves shall have their setpoints verified every five years as follows:
1.

The Valve tests shall be distributed over a 60 month period, such that (N/60) x Z valves have been tested each refueling outage (where N equals the number of months from the start of the 60 month period and Z is the number of valves in the program).

b.

For safety and relief valve testing, the procedure of PTC25.3 shall be used for setpoint verification.

PTC25.3 shall not be used for administrative purposes. Palisades Administrative procedures shall govern items such as personnel and equipment qualifications, procedure formats and test conduct.

Category C Check Valve Testing

a. Category C Check Valves shall be exercised to the position required to fulfill their safety function at least once every three months unless such operation is not practical during plant operation and then as modified below.
b.

If only limited operation is practical during Plant operation, at least once every three months each valve shall be:

1.

Part stroke exercised during plant operation, and

2.

Full-stroke exercised during cold shutdowns.

c. Valves which c~nnot be exercised during Plant operation shall be:

I.

Specifically identified in the form of a cold shutdown test bash, and 2.,

  • Full~stroke exercised during cold shutdowns.
d. _' E:uU-stroke exercising during cold shutdowns for all valves -not full -stroke exercised during Pl ant/ operation sha 11 be on a frequency determined by the intervals *between s_hutdowns as fo 11 ows:
1.

\\

For1 intervals of three months or longer, 'exercise each cold shutdown.

2.

For intervals less than three months, full-stroke exercise is not required unless three months have passed since the last full-stroke exercise.

  • , '".. *r~

--~*.

-~

PAllSADES\\ NUCLEAR PLANT ENGINEERING MANUA

L. PROCEDURE

TITLE:

INSERVICE TESTING OF PLANT VALVES Proc No EM-09-02 Revision 14 Page 9 of 17

e. Valves which cannot be exercised according to Steps 5.2.3.a-d shall be:
1.

Specifically identified as a part of a relief request included in this procedure,

2.

Grouped with* valves of similar type and service conditions, and

3.

Placed on a disassembly and inspection interval of not greater than six years, unless longer intervals are justified in accordance with Generic Letter 89-04, "Guidance on Developing Acceptable Inservice Testing Programs".

f. Category C normally open valves whose function is to prevent reverse flow shall be tested in a manner which proves the di.~k travels to the seat promptly on cessation or reversal of fl ow.

Confirmation the disk is on the seat shall be by:

~

I.

Vtsual observation.

2.

An electrical signal initiated by a position indicating device.

3.

Observation of appropriate pressure i ndi cations in the system.

4.

By observation of pumps for reverse rotation, or

5.

By any other positive means.

g. Category C normally closed check valves' whose function is to open on rever~al of:pressure differential shall be tested:

I.

By proving the disk moves promptly away from the seat when the closing differential pressure is. removed and flow is initi'ated, or

  • t/

When a mechanical opening force is applied to the disk. _

h.

Confirmation that the disk moves.away- 'from the seat shall be by:

~

I.

Visu:al observation.

2.

By electrical signal initiated by a position indicating device.

3.

By observation of substantially free flow* through the valve as indicated by appropriate pressure indications in the system, or

4.

By any other positive means.

PALISADES NUCLEAl\\'P.LANT ENGlNEERING.-MANUAt PROCEDURE TITLE:

INSERVICE TESTING OF PLANT VALVES Proc No EM-09-02 Revision 14 Page 10 of 17

i. This test may be performed with or without flow through the valve.

If the test is without flow through the valve, the following shall occur:

1.

A mechanical exerciser shall be used to move the disk.

2.

The force or torque delivered to the disk by the exerciser shall be limited to less than ten percent of the equivalent force or torque represented by the minimum emergency condition pressure differential acting on the disk,: or

3.

To 200 percent of the actual observed force or torqtie required to perform the exercise on the valve when the valve is new and in good operating condition, whichever is less,

4.

Except for vacuum breaker valves, the exerciser force or torque delivered to the disk may be equivalent to the desired functional pressure differential force.

z v

~~

j. The disk movement shall be sufficient to prove the disk moves freely off the seat.
1.

For swing and tilting disk valves, if the test is made by use of fluid flow through the valve, the pressure differential for equivalent flow shall be no greater than observed during preoperational test.

2.

For all types of check valves, it shall be shown that disk movement is sufficient to provide the required accident condition flow rate as listed in the -FSAR or Technical Specification.. provides a listing of the full-stroke safety analysis required flows and basis (source) documents for which the valves must be tested.

5.2.4 Category A Valve Leak Testing a._ Category A valves are those for which seat leakage is limited to a

~~speci fie maximum amount.

These valves shall be leakage tested as c-iHf(> 11 ows :

1.-

Category A valves which are part of containment isolation shall be tested in accordance with Federal\\~egulation 10CFRSO, Appendix J, per Relief Request Number 11.

2.

Event V pressure isolation valves shall be leak tested in accordance with the requirements of Technical Specifications Table 4.3.l and IWV-3420.

3.

-leakage tests shall be conducted at least once every two years and shall be performed in accordance with IWV-3423, IWV-3425.

5.2.5 -TITLE

INSERVICE TESTING, Of-P_LANT VALVES-Proc No EM-09-02 Revision 14 Page 11 of 17

4.

Valves which function in the course of other Plant Operations or other testing of the same interval in a manner which demonstrates functionally adequate leak tightness need not be additionally tested.

However, documentation for each valve showing the requirements of IWV are met shall be contained in.

Category D Valves Category D valves are those which are actuated by an energy source capable of only one operation, such as rupture disks or explosively actuated valves.

Palisades has no such valves meeting these characteristics in the Inservice Testing Program.,

5.2.6 Rapid Acting Valves

a. Valves with stroke times less than 2.0 seconds may be:

-~:

1.

Documented via a Relief Request, and

2.

Treated as Rapid Active Valves.

These valves may have a limiting stroke time of two. s'econds applied.

Upon exceeding two seconds, the valve shall be declared inoperable and corrective action taken per Step 5.4.1.

5.2.7 Motor Operated Valve Testing 5.2.8

a. Palisades motor operated valves contained in the IST Program are stroke time tested in accordance with Step 5.2.l of thi:s procedure.
b. Additionally,,motor operated valve actuators may b.e tested in accordance with the requirements of NRC IE Bulletin 85-03, "Motor Operated-Valve Conman Mode Failures During, Plant Transients Due to Improper Switch Settings", dated 11/15/85. The program for testing in, accordance with this bulletin is controlled. by the System
  • _.t:~fngineeri ng Department.
  • -1~~-~~¥;;.-~:._>~"-*'*

ltei!ijd1,-Pqs1t1on Indication

,.~-~*{.. ~~_}": ~-::~--:~-.

a... Valves with: remote position indicato~s 'shall be observed once every two years to, verify valve operation is,accurately indicated.

\\

b.

Valve disc *movement is determined by exercis*ing the valve while observing an appropriate indicator wMch signals the required change of disc position.

..:'.":-~*...

I I

Proc No EM-09-02 Revision 14 Page 12 of 17

.TITLE:

INSERVICE TESTING: OF' PilNJ:*~VALVES

c. Actual valve. movement or observ;ng ;ndfrect ev;dence, such as changes in system pressure, flow rate, level, or temperature, which reflect stem or disc pos;tion will be used* to ver;fy that remote valve position indicators agree with valve travel direction.

5.2.9 Valve Testing SunmarY

a.

In summary, the following table outlines the test requirements for all valves contained in the IST Program.

Valve Category Function A

A B c Active Passive Active (RV's &

PRV's)

Active c

(check Leak Test Procedure 5.2.4 5.2.4 None None.

Exercise Test Procedure 5.* 2.1. :.. _

None 5.2*.1-*

5.2.2 valv.es)"* Active None 5~2'£-3 *.* * *

'. D Not applicable for Palisades****.* :',;;t:*:*2.c...

Special Text None None None None None NOTE:

No test is required for Category B and C passive v_a.lves.*

5.3 PROGRAM ADMINISTRATION

5. 3.1 Test Procedures* -

Each va lv.e'_ test pr;,ocedure in this program stiatl' be performed under:

' j.

~ '

a Technital Specifications Surveillance Procedure an* Operating Procedure

. *-*~* a Maintenance Procedure, or

~~:-}<'a, Periodic Activity, or

~~~r;lf~~~-.. *",*~:Operations Log The'sii*doctiments shall be written to comply, with this procedure and ASME Sectton'Xl~ Subsection IWV as amended by/the Technical Specifications.

A s1ngle* procedure may be used for multiple* P-ieces of equipment, however applicable data, precautions, operating reqli_ire111ents, s~tpoint, etc., shall*be addressed for each piece ofequipment:.

'....... * - *~: *: \\ :: *,

a.

The ISi Coordinator shall establish reference values for each valve in order to trend changes in the valve's operating condition. The reference stroke time shall be the ~xpected stroke time based on the past historical operating data for each valve. The stroke time reference value for each valve shall be mafntained by the ISI Engineer in the Valve Inservice Testing Record.

PALlSADES. NUCLEA1t PLANT ENGINEERING MANUAL PROCEDURE TITLE:

INSERVICE TESTING OF PLANT VALVES Proc No EM-09-02 Revision 14 Page 13 of 17

b.

The ISi Coordinator shall establish alert limits based upon the reference value.

For valves which trend up and exceed these values, the ISi Coordinator shall coordinate with the System Engineer to take corrective action in accordance with Step 5.4.2b.

The Alert Ranges shall be established for each valve as follows:

1.

The reference va 1 ue sha 11 be increased by 25 percent for valves with stroke times greater than ten seconds.

2.

The reference va 1 ue sha 11 be increased by 50 percent for valves with stroke times equal to or less than ten seconds, except for Rapid Acting Valves.

Rapid Acting Valves are addressed in Step 5.2.6.

c. The ISi Coordinator shall establish limiting stroke times for each valve based on the reference values which will be set at a value that will most likely indicate valve degradation. These limiting stroke times shall be established as follows::

(.*

_'t:

I.

For valves with reference value stroke times of 10 *seconds br less, the reference value shall be increased by 75% to obtain the 1 imiting stroke time.

2.

For valves with reference value stroke times of greater than 10 seconds, the reference value shall be increased by 50% to obtain the limiting stroke time.

5.3.2 Scheduling

a.

The basic scheduling mechanism for Technical Specifications Surveillance. Procedures shall be in accordance with Palisades Administrative! Procedure 9.22, "Scheduling of~ Surveillance Procedures".*: These will be administered by the Technical Specification Surveillance Procedure Program Coordinator (TSSPA).

b..Other types of procedures and documents used to obtain the data

. required by this program shall be scheduled in accordance with

  • ,~.epartment procedures.
c. *Unless otherwise specified, each inservice test surveillance requirement *shall be performed within.*the specified time interval with (see Relief Request 23):
1.

A maximum- *allowable extension not. to exceed 25% of the surveillance interval, and

2.

A total maximum combined interval time for any three consecutive surveillance intervals not to exceed 3.25 times the specified surveillance interval.

PALI SADES* NUCtEAif: PLANT ENGINEER;ING MANUAL :PROCEDURE Proc No EM-09-02 Revision 14 Page 14 of 17 TITLE:

INSERVICE TESTING OF PLANT VALVES 5.3.3 Modified Test Frequencies It is the responsibility of the ISi Engineer to notify the TSSPA of any change in the testing frequency for a particular piece of equipment.

This change shall be documented in the test record.

5.4 NON-CONFORMANCE/CORRECTIVE ACTIONS/DATA EVALUATION 5.4.1 If any valve fails to exhibit the required change of stem or disk position, corrective action shall be taken as follows:

a.

The shift Supervisor shall be immediately notified.

b.

The Shift Supervisor shall immediately declare the nonconforming piece of equipment inoperable.

c.

The Shift Supervisor shall review the Technical Specifications f9r applicable Limiting Conditions of Operation and Action Statement~.

d.

Corrective action shall be immediately. initi.ated.

e. Repairs shall be made before power operations for valves tested
  • only during nonoperating conditions and,
f. A retest showing acceptable operation shall be conducted before a nonconforming valve is declared operable.

5.4.2 For Category A & B Exercise Testing, two evaluations are performed on the "As Received" stroke time:

a.

The Shift Supervisor compares the recorded stroke time with the limiting valueL This initial evaluation shall ensure the valves are capable of* performing their function.

If the valve fails to stroke in* the required time or exhibits other unsatisfactory actions, the following actions shall be taken:

3.
4.
5.

The affected valve shall be declared inoperable by the Shift Supervisor.

The Shift Supervisor shall review.the Technical Specifications for applicable Limiting Conditions of Operation and Action Statements.

Corrective action shall be i11111ediately initiated.

The valve operability status and associated corrective action documents sha 11 be noted on the Acceptance Criteria and Operability Sheet of the test procedure, and The test procedure shall continue to be routed according to the Issue and Routing Sheet.

  • PAUSADES NUCLEA~- PLANT ENGINEERING MANUAt PROCEDURE TITLE:

INSERVICE TESTING OF PLANT VALVES Proc No EM-09-02 Revision 14 Page 15 of 17

b.

A second evaluation is performed by the ISI Coordinator

1.

Per Subparagraph IWV-3417, "Corrective Action" if stroke time increases by 25 percent or more of reference value for valves whose stroke time is greater than ten seconds, the test frequency shall be increased to once per 31 days until corrective action is taken.

2.

If stroke t;me increases by 50 percent or more of reference value for valves whose stroke time is ten seconds or less (except Rapid Acting Valves) the test frequency sha 11 be increased to once per 31 days.

3.

Items 1 and 2 are considered to represent valves having degradation requiring increased testing frequency.

This is known as an a 1 ert condition. Va 1 ve reference va 1 ues and alert limits shall be maintained and controlled by the ISI Coordinator as part of the valve test record.

~

4.

Valves shall be returned to normal frequency when correcti~e action is complete and a successful retest is completed justifying continued operation of the valve.~.

5.

If the ISi evaluati~n reveals conditions whic~ cause a valve to be inoperable, the ISI Coord.inator shall* take steps to assure the actions of Step 5.4.1 are performed.

5.4.3 For Category C safety and relief valve testing the following action shall be taken if any valve fails to function properly during a regular test.

a. Additional valves in the system shall be tested such that the total number tested 1s [(N + 12)/60) x z.

Where:

N

  • the total number of months from time zero in the five year test interval and Li:~t~:.

Z

  • the total number of valves in the test group.
b. : If. any of the additional valves fail to function properly, all valves in the system shall 'be test~d:

5.4.4 If a Category C check valve fails to exhibit the required change of disk position by testing the following corrective actions shall be taken.

a.

The valve shall be declared inoperable.

b.

Corrective action shall be taken.

(Prior to;startup for valves only tested during shutdowns).

'PAUSADES* NUCtEA~ PLAN!

~:ENGINEERING -MANUAL PROCEDURE

,-,.. TITLE:

INSERVICE TESTING OF Pl.ANT VALVES Proc No EM-'09-02

  • Revision 14 Page 16 of 17
c. A successful r~test shall be performed prior to declaring the valve operable.
d.

For check valves disasseml>led and inspected in accordance with Step 5.2.3e, any failure of the valve to full-stroke or if there is binding or failure of intervals, the remaining valves in the group shall be disassembled, inspected and manually full-stroked during the same outage.

This requirement is from Generic Letter 89*04, Position #2.

5.4.5 For Category A valve leak testing, the-following criteria shall apply for corrective action.

5.4.6

a.

Leakage rates which reduce the margin between baseline and maximum permissible rate by 50% shall be placed on 31 day testing frequency until corrective action is taken and. a __. successful retest is completed.

b.

For leakage trends which show the maximum permissible leak r~te wi 11 be exceeded by more than 10%

  • at the next scheduled test interval the valve shall be replaced or repaired and a successful retest completed.

~

Trending The ISi coordinator shall be responsible to record and*trend test data in order to pred.fct when valve degradation wi_l l... exceed l i mi ts.

The goal of this *trending is to maintain valve function and-to perform needed repairs during convenient times prioruto~ the valve becoming inoperable.

Trending shall normally be accomplished with the aid of personal comJ>uters and standard data management :software available throughtout the industry.

The ISi Coordinator shall maintain a status summary of all valves tested in t~e-IST program. This status sumary_ shall-be av~ilable for review by auditors and pl ant personnel.

Thi.s summary may al so be distributed as appropriate.

The status sumary format is presently under development.

5

  • 5 RECORDS-;

5.5.1 va.;!i~:records: shall consist of the following documents:

~J~i~!(7-~ *.

a.*c~Y,Tedinical Spedfications Surveillance; Procedures*

/

b. Valve Inservice Testing Trending Records c.- Applicable Work Orders
d. Applicable corrective action documents
e. Valve Status Summary Report (under development) :-'":

These documents shall be maintained as lifetime Plant. reco.rds. These documents should be filed under the Uni form Filing Index numbers 22-22-03.

PALISADES NUCLEAR PLANT ENGINEERING MANUAL PROCEDURE TITLE:

INSERVICE TESTING OF PLANT VALVES 6.0 ATTACHMENTS Proc No EM-09-02 Revision 14 Page 17 of 17 6.1, "Valve Reference List in Alpha Numeric Order" 6.2, "Valve Reference Flow Rates" 6.3, "Cold Shutdown Testing Basis" 6.4, "Relief Request Basis"

PALISADES NUCLEAR PLANT INSERVICE TEST PROGRAM VALVE TEST TABLE Proc No EM-09-02 Revision 14 Page 1 of 1 This table is maintained as an "Engineering Aid" in accordance with Administrative Procedure 10.42. See the ISI Section for details.

PALISADES NUCLEAR PLANT VALVE REFERENCE FLOW RATE Proc No EM-09-02 Revision 14 Page 1 of 1 This table is maintained as an "Engineering Aid" in accordance with Administrative Procedure 10.42. See the ISI Section for details.

CSl:

CS2:

CS3:

CS4:

CSS:

CS6:

CS7:

CSB:

CS9:

CSlO:

CSll:

CS12:

CS13:

CS14:

CSIS:

CS16:

CS17:

CSIS:

COLD SHUTDOWN INDEX RV Cold Shutdown ;xercise Testing Proc No EM-09-02 Revision 14 Page 1 of 34 Cold Shutdown Testing of Containment Isolation Valves for Primary Coolant Pump Deleted Cold Shutdown Exercise Testing of Containment Isolation Valves for Let Down Flow Cold Shutdown Exercise Testing of Volume Control Tank Isolation Valve Cold Shutdown Exercise Testing of Boric Acid Tank Isolation Valves Cold Shutdown Exercise Testing of Primary Coolant Back Flow Check Valves Cold Shutdown Exercise Testing of System Isolation Valves Cold Shutdown Exercise Testing of PCS Backflow Valves Cold Shutdown Exercise Testing of SIRW Minimum Rea.irculation Isolation Valves Cold Shutdown Exercise Testing of LPSI Pumps Backflow Valves Cold Shutdown Exercise Testing of SIRW Backflow Check Valves Cold Shutdown Exercise Testing of SIRW Tank Outlet Valves Cold Shutdown Exercise Testing of Containment Sump Valves Cold Shutdown Exercise Testing of the Main Steam Isolation Valves Cold Shutdown Exercise Testing of Service Water Discharge Valves from Compon~nt Cooling Heat Exchanger Cold Shutdown Exercise Testing of Component Cooling Supply and Containment Valves Cold Shutdown Exercise Testing of Inlet.Flow Valves to Component Cooling Heat Exchanger CS19:

Cold Shutdown Exercise Testing of Containment Purg~ Air Exhaust Valves CS20:

Cold Shutdown Exercise Testing of Isolation Valves for Service Water Supply and Return CS21:

Cold Shutdown Exercise Testing of Air Cooler Isolation Valves for Service Water Supply and Return CS22:

PRV Cold Shutdown Exercise Testing

CS23:

CS24:

CS25:

CS26:

CS27:

CS28:

Proc No EM-09-02 Revision 14 Page 2 of 34 Cold Shutdown Testing of Main Feedwater Regulating and Bypass Valves Cold-Shutdown Testing of Primary Coolant System Block Valves Cold Shutdown Testing of Chemical and Volume Control SIRW Tank Motor Operated Valve Cold Shutdown Testing of Chemical and Volume Control Boric Acid Injection Check Valves Cold Shutdown Testing of LPSI and HPSI Check Valves Cold Shutdown Testing of CCW Heat Exchanger Service Water Flow Control Valves

- 1

/

\\

\\

SYSTEM:

VALVES:

CATEGORY:

FUNCTION:

COLD SHUTDOWN TESTING BASIS NUMBER I Primary Coolant System (M-201-2)

Proc No EM-09-02 Revision 14 Page 3 of 34 PRV-1067, PRV-1068, PRV-1069, PRV-1070, PRV-1071 AND PRV-1072 B

CLASS:

1

1.

Reactor Coolant Pressure Boundary Isolation Valves.

2.

Reactor Vessel vent valves, Primary Coolant System high point vent valves (from Pressurizer}, added per NUREG 0737.

TEST REQUIREMENT:

1.

IWV-3411; Test Frequency - Exercise at least once every three months.

BASIS:

Exercising of these valves during operation breaches the Primary Coolant System and Reactor Coolant Pressure Boundairy.

This creates an inter-system LOCA.

ALTERNATIVE TESTING:

Exercise during cold shutdowns per Surveillance Procedure Q0-6, but not necessarily more frequently than once each quarter.

VERIFICATION METHOD:

The performance of these valves shall be determined by recording and trending stroke time values in the open and close direction per the instructions of QO~s. Valve position is determined by observing the valve position indicating lights located in the Control Room.

CORRECTIVE ACTION:

Should either valve fail to meet the stroke time acceptance criteria, corrective action per procedure EM-09-02 Step 5.4.1 shall be taken.

Proc No EM-09-02

.*_:.,.§

-*.. ~

I COLD SHUTDOWN TESTING BASIS NUMBER 2 Revision 14 Page 4 of 34 SYSTEM:

Chemical and Volum~ Control (M-202-ll VALVES:

CV-2083, CV-2099 CATEGORY:

FUNCTION:

A CLASS: 2 Containment isolation valve for primary coolant pump seal controlled bleedoff line to volume control tank.

TEST REQUIREMENT:

1.

IWV-3411; Test Frequency - Exercise at least once every three months.

COLD SHUTDOWN BASIS:

Shutting this valve during primary coolant pump operation (i.e., any hot plant condition) stops pump seal leakoff flow.

Since thi.s flow:.f provides both seal lubrication and cooling, interrupt.ion~can cause~

seal failure and will cause a relief valve to;-llft;. resulting in the unnecessary loss of primary coolant as radioact.ive* waste **,._

ALTERNATIVE TESTING:

Exercise during. cold shutdowns per Surveillance Procedur~ Q0-06, but not necessarily.more frequently than once each quarter.

VERIFICATION METHOD:

Operability of these va 1 ves sha 11 be determined by-~ observing and recording the stroke* time from the open to closed positi.on*~ Valve position is determined by observing the valve. position and indicating lights located on c~ntrol panel EC-11.

~

CORRECTIVE. ACTION:*

ShJJi~-- either of these valves fail to meet the stroke time or leak ratiF1requirements, corrective action as outlined i-n. Procedure Step 5.* 4.1 sha 11 be taken.

\\

COLD SHUTDOWN TESTING BASIS NUMBER 3 DELETED Proc No EM-09-02 Revision 14 Page 5 of 34

COLD SHUTDOWN TESTING BASIS NUMBER 4 Proc No EM-09-02 Revision 14 Page 6 of 34 SYSTEM:

Chemical and Volume Control (M-202-1)

VALVES:

CV-2009 CATEGORY:

A CLASS: 2 FUNCTION:

Containment isolation valve for letdown flow.

TEST REQUIREMENT:

1.

IWV-3411; Test Frequency - Exercise at least once every three months.

COLD SHUTDOWN BASIS:

Interrupting letdown flow at normal operating temperature is undesiyable because reinitiation of flow can thermally shock the regenerative hj:!at exchanger.

In addition, closing this valve at PCS pressures greater than 600 psia will cause relief valve RV-2006 to lift unless the letdown~line is isolated prior to exercising this valve. The ~olation function can only be verified safely at lower PCS pressures and temperatures.

ALTERNATIVE TESTING:

Exercise during cold shutdown, but not necessarily more often than once each quarter, as allowed by Procedure Step 5.2.1.1. Exercising shall be performed according to procedure Q0-6, "Cold Shutdown Valve Test Procedure (includes Containment Isolation Valves)".

Leak testing shall be performed in accordance with R0-32-36 as stated in Procedure Step 5.2~4.lA and Relief Request 12.

VERIFICATION METHOD:

Operab1lity of this valve shall be determined by observing/recording strok~ time from open to closed position. Valve position is determined by obser.ving the valve position indicating lights located on EC-12.

L~ak testfog shall be performed in accordance with Relief Request 12.

CORRECTIVE ACTION:

Should this valve fail to meet the stroke time or leak rate requirements, corrective action as outlined in Procedure Step 5.4.1. shall be taken.

COLD SHUTDOWN TESTING BASIS NUMBER 5 Proc No EM-09-02 Revision 14 Page 7 of 34,

SYSTEM:

Chemical and Volume Control (M-202-IAl VALVES:

M0-2087 CATEGORY:

FUNCTION:

B CLASS: 2 Volume Control Tank outlet isolation valve.

Valve Closes on safety injection signal so that full charging pump flow comes from the concentrated Boric Acid Tanks or SIRW tank.

TEST REQUIREMENT:

I.

IWV-3411; Test Frequency - Exercise at least once every three months.

COLD SHUTDOWN BASIS:

Exercising this valve requires interruption of charging and letdown~flow.

In this condition with the Primary Coolant System hot, the regenera'tive heat exchanger would be thermally shocked when th&. charging/letdown flow is reestablished.

ALTERNATIVE TESTING:

Exercise during cold shutdowns per Surveillance Procedure Q0-06, but not necessarily more frequently than once each quarter.

VERIFICATION METHOD:

Operability of thi~ valve shall be determined by observing/recording stroke time from open to closed position. Valve position is determined by observing valve position indicating lights located on EC-12.

Leak rate closure capability shall be considered acceptable when the acceptance criterja of Checklist 2.2 are met.

CORRECTIVE ACTION:

  • -:r*
    • c;,

Should this v~lve fail to meet the stroke _time or closure rate requirements, corrective action as outl,j.ned in Procedure Step 5.4.1 shall be taken.

\\

Proc No EM-09-02 COLD SHUTDOWN TESTING BASIS NUMBER 6 Revision 14 Page 8 of 34 SYSTEM:

Chemical and Volume Control (M-202-lAl VALVES:

M0-2169, M0-2170 CATEGORY:

B CLASS: 2 FUNCTION:

1.

Valves open on safety injection signal to provide the concentrated boric acid gravity feed path to the charging pump suctions.

2.

Valves isolate to maintain Boric Acid Tank levels.

TEST REQUIREMENT:

1.

IWV-3411; Test Frequency - Exercise at least once every three months.

BASIS:

Opening these valves during nor~al plant operatiqn would result ini significant reactivity change from the inject. -i~n.o.f c. on.centrated boric

  • acid into the PCS.

The resulting reactor power/PCS.t~~perature excursi could cause a reactor trip. During hot shutdown, since significant PCS boration does not occur, exercising these valves can. result in the unnecessary generation of large quantities of radioactive-waste, especially late in.core life.

ALTERNATIVE TESTING:

Exercise during cold shutdown, but not necessarily mar~ frequently than once each quarter, as allowed by Procedure. Step 5.2.1.1. Exercising shall be performed. accor~ing to procedure Q0-6,.. "Cold Shutdown Valve Test Procedur~ (includes Containment Isolation V~lves)".

VERIFICATION.METHOD:

~-,._.

Op~rability of these valves shall be determined by observing/recording stroke time from close to open position. Valve position is determined by obs**rvir:ig valve position indicating lights,on panel EC-12.

Closure*-

verif.fcation is provided by recording Co,ncent"rated Boric Acid Tank levels per LIA-0206 and LIA-0208 p~r Operat i ans log.

\\.

\\

CORRECTIVE ACTION:

Should these valves fail to meet the stroke time or closure requirements, corrective action as outlined in Procedure Step 5.4.1 shall be taken.

COLD SHUTDOWN TESTING BASIS NUMBER 7 Proc No EM-09-02 Revision 14 Page 9 of 34 SYSTEM:

Engineered Safeguards CM-203-ll VALVES:

CK-ES3101, CK-ES3116, CK-ES3131, CK-ES3146 CATEGORY:

FUNCTION:

A,C CLASS: 1 Prevent backflow of primary coolant into safety injection piping while providing a flow path for safety injection water into the four PCS cold 1 egs.

TEST REQUIREMENT:

1.

IWV-3521; Test Frequency - Exercise at least once every three months.

BASIS:

During hot plant conditions, the LPSI pumps will not develop sufficient head to overcome PCS pressure, so full flow testing can only be performed during cold shutdown conditions. Part stroke exercising using a charging pump can be performed during hot or cold shutdowns.

Part stroke exercising is not practical during normal plant operation, however, because of damage caused by thermal forces as documented in Relief Request 17.

ALTERNATIVE TESTING:

These valves shall be tested as follows:

1.

During normal plant operations, partial stroke testing shall be performed on a quarterly bas~s per Inservice Testing Procedure Q0-19.

2.

During refueling outages with the vessel head removed, full-stroke testing per Inservice Testing Procedure R0-65 shall be performed.

VERIFICATIOff"ETHOD:

  • ~-:,::..

Ver"i.f.ication of valve performance shall occur through the monitoring of degradation via cold shutdown procedure.Q0-88. This test verifies the ability of these valves to pass approximately 1500 gpm flow.

Verification of valve leakage shall occur via the performance of S0-9.

This procedure invokes an acceptance criteria of less than 1 gpm leakage.

CORRECTIVE ACTION:

Should these valves fail to meet their stroke or leak requirements, corrective action as outlined in Procedure Step 5.4.1 shall be taken.

~: -

COLD SHUTDOWN TESTING BASIS NUMBER 8 Proc No EM-09-02 Revision 14 Page 10 of 34 SYSTEM:

Engineered Safeguards CM-203-2)

VALVES:

CV-3001, CV-3002 CATEGORY:

FUNCTION:

B CLASS: 2 Serve as system-isolation valves which open during accident conditions to initiate containment spray.

TEST REQUIREMENT:

1.

IWV-3411; Test Frequency - Exercise at least once per:.every three months.

BASIS:

Exercising these valves during normal operation may result in dra i rl~i ng the containment headers. This result would require a containment entr,iSto restore header levels with the pl ant at power,. -

T~i s is-not consistent with the ALARA, concept.

*'"{' **;

ALTERNATIVE TESTING:..

Exercise duri n-g cold shutdown in accordance ~i th Survefl l a'nce Procedure Q0-10, but not necessarily more frequently than once each quarter.

VERIFICATION METHOD:

Performance of these valves shall be determfoed by measuring and trending stroke times from the closed to open position.

An. acceptance criteria limit of 10. se~~nd~ has been placed on these valves~~ 'This criteria is based on system response time since it is more limiting than component response time.,-- _

CORRECTIVE ACTION:

Shou'ld:.either valve fail to meet the stroke time acceptance criteria, corrective action as outlined in Procedure Step 5.4.1 shall be taken.

/

\\*~

  • l'_J H;.~1 COLD SHUTDOWN TESTING BASIS NUMBER 9 Proc*No EM-09-02 Revision 14 Page 11 of 34 SYSTEM

Engineered Safeguards CM-203-2)

VALVES:

CK-ES3103, CK-ES3118, CK-3133, CK-ES3148 CATEGORY:

FUNCTION:

A, C CLASS: 1 Prevent backflow of PCS/safety injection tank water into the LPSI p1p1ng and pumps piping while providing a flow path for LPSI water into the four loop safety injection lines.

TEST REQUIREMENT:

1.

IWV-3521; Test Frequency - Exercise at least once every three months.

BASIS:

During power operation the LPSI pumps cannot develop sufficient he~d to overcome Primary Coolant System Pressure. Therefore the above check valves cannot be full or partial stroke exercised.a ALTERNATIVE TESTING:

Exercise these valves each cold shutdown per Surveillance Procedure Q0-8B, but not necessarily more frequently than once each quarter.

VERIFICATION METHOD:

Performance of these valves shall be determined by measuring and trending flows and pressures via Q0-88. Acceptable performance is indicated by the ability to pass 1500 gpm fl ow rate.

CORRECTIVE ACTION:

Should any of these valves fail to meet the flow rate requirements of Q0.. 88', corrective action as outlined in Procedure Step 5. 4. 1 sha 11 be taken.~"

  • .~:/f:~*::',: '

COLD SHUTDOWN TESTING BASIS NUMBER 10 Proc No EM-09-02 Revision 14 Page 12 of 34

-.... ~. :.**.. ~ -

SYSTEM:

Engineered Safeguards (M-204-lB)

VALVES:

CV-3027, CV-3056 CATEGORY:

A CLASS: 2 FUNCTION:

SIRW tank minimum recirculation isolation valves.

-TEST REQUIREMENT:

1.

IWV-3411; Test Frequency - Exercise at least once every three months.

BASIS:

  • .r.:

Failure of the above valves during testing would impair operabilit,iof the Safety Injection System by eliminating the minimum flow path for tH~ High and Low Pressure Safety Injection pumps thus reducingthe operatiorj)l readiness of these systems.

~

ALTERNATIVE TESTING:

Exercise each cold shutdown per Surveillance Procedure Q0-2, but not

  • necessarily more frequently than once each quarter.

VERIFICATION METHOD:

The performance of these valves shall be determined by recording and trending stroke time values from the open to the close position per the instructions of-Q0~2. Valve position is determined by observing the valve position indicatin~ lights located in the Control Room~

Leak testing requires performance of a modification.

CORRECTIVE AQ.'JON:-

Sho~{~-ei ther valve fail to meet the stroke time acceptance criteria, corr'ect he action per Procedure Step 5. 4. ~ sha 11 be taken.

COLD SHUTDOWN TESTING BASIS NUMBER 11 Proc No EM-09-02 Revision 14 Page 13 of 34 SYSTEM:

Engineered Safeguards (M-204-ll VALVES:

CK-3201, CK-3192 CATEGORY:

FUNCTION:

c CLASS: 2 LPSI Pump discharge check valves which provide a flowpath for LPSI and Shutdown Cooling Flow and prevent backflow through the individual LPSI pumps.

TEST REQUIREMENT:

1.

IWV-3521; Test Frequency - Exercise at least once every three months.

BASIS:

To verify full-stroke exercise of the above check valves*requires full flow testing with the LPSI Pumps in service. This test is not possible during power operation since the necessary flow path would require the LPSI pumps to inject into the PCS.

The LPSI pumps cannot develop sufficient head to overcome the PCS normal operating pressure. Therefore a full or partial stroke test cannot be performed quarterly.

ALTERNATIVE TESTING:

Full-stroke *exe~cise each cold shutdown per Surveillance Procedure QO-io, but not necessarily more frequently than once each quarter.

VERIFICATION METHOD:

The performance of'these valves shall be determined by observing and recording shutdown cooling flow rates equal to or greater than 3000 gpm per Q0_-10.

CORRECTIVE A~TION:

Shoul:d* either va 1 ve fail to meet fl ow rate requirements, corrective-action per Procedure Step 5.4.l shall be taken.,*

\\

  • i:

COLD SHUTDOWN TESTING BASIS NUMBER 12 Proc No EM-09-02 Revision 14 Page 14 of 34 SYSTEM:

Engineering Safeguards CM-204-lB)

VALVES:

CK-ES3400, CK-ES3401, CK-ES3402, CK-ES3403, CK-3404, CK-3405, CK-3406, CK-3407 CATEGORY:

FUNCTION:

c CLASS: 2 The above check valves provide a flow path from the hydrazine and sodium hydroxide tanks to the safety injection pumps to allow the Iodine Removal System to reduce the post-accident level of fission products in the containment area. These check valves also prevent backflow of SIRW tank water into the hydrazine and sodium hydroxide tanks after a Recirculation Actuation Signal {RAS).

TEST REQUI.REMENT:

I.

IWV-3521; Test Frequency - Exercise at least once every *three months.

~

BASIS:

To verify fu 11-stroke capabi l ity requires forward 0

fl ow: and. reverse fl ow.

testing the subject valves with the iodine removal* tanks' isolated.

Performance of this test during normal power operations places the plant in a Limiting Condition of Operation and reduces the operational readiness of the Iodine Removal System.

Therefore the check valves will be tested during cold shutdowns.

The test method of Q0-13 does not allow quick restoration in the event of an accident during testing~

. ALTERNATIVE TESTING:

Exercise durtng cold shutdowns per Surveillance Procedure.Q0-13, but not more frequently than once per each quarter.

VERIFICATION* METHOD:

  • ':<*~.-=-.

Che'clt: valves.CK-3400, CK-3401 and CK-3403 shall pass a two gallon volume of":water in 1 ess than or equa 1 to 17 seconds. A successful flush--of check valves CK-3404, CK-3405, CK-3406 and.CK-3407 constitutes an acceptable

  • full-stroke test.

\\

CORRECTIVE ACTION:

Should any valve fail to meet full-stroke flow rate for check valves requirements, corrective action per Procedure Step 5.4.1 shall be taken.

COLD SHUTDOWN TESTING BASIS NUMBER 12A Proc No EM-09-02 Revision 14 Page 15 of 34 SYSTEM:

Engineering Safeguards {M-204-181 VALVES:

CV-0437A, CV-04378, CV-0438A, CV-04388 CATEGORY:

FUNCTION:

8 CLASS: 2 Iodine Removal System, hydrazine and sodium hydroxide tank discharge isolation valves.

TEST REQUIREMENT:

1.

IWV-3411; Test Frequency - Exercise at least once every three months.

BASIS:

To full-stroke exercise the above valves requires isolating the Iodine Removal tanks.

Isolating the Hydrazine and Sodium Hydroxide Tanks places the plant in a Limiting Condition of Operation and reduces the operational readiness of the Iodine Removal System.

Therefor~the above valves will be full-stroke exercised during cold shutdowns.

Due to access limitations, the test system cannot be quickly restored in the event of an accident during testing.

ALTERNATIVE TESTING:

Exercise during cold shutdowns per Surveillance Procedure Q0-13, but not more frequently than once each quarter.

VERIFICATION METHOD:

Control Valves CV-0437A, CV-04378, CV-0438A and CV-04388 shall stroke in less than or equal to 30 seconds. This criteria is based on system response requirements.

CORRECTIVE ACTION:

Should any valve fail to meet stroke time limit for control valve requirements, corrective action per Procedure Step 5.4.1 shall be taken.

COLD SHUTDOWN TESTING BASIS NUMBER 13 Proc No EM-09-02 Revision 14 Page 16 of 34 a

SYSTEM:

Engineered Safeguards (M-204-18)

<::)

\\)'

'~. I

~

VALVES:

CV-3031, CV-3057 CATEGORY:

B CLASS: 2

~ FUNCTION:

()

<I SIRW tank outlet isolation valves.

TEST REQUIREMENT:

1.

IWV-3411; Test Frequency - Exercise at least once every three months.

BASIS:

~'f Exercising CV-3031 and CV-3057 eliminates the suction source of mor~ than one high and low pressure safety injection pump.

During*normal pow~r operations this testing. places the plant in an action statement pef'.

Technical Specification 3.3.2, and thus reduces thJ! operational readine.

of these systems. Therefore these valves will be exercised at cold shutdowns.

ALTERNATIVE TESTING:

Exercise each cold shutdown per Surveillance Procedure Q0-2, but not necessarily more frequently than once each quarter.

~I 1.u VERIFICATION METHOD:

t The performance of' these valves shall be determined by recording and trending the stroke time values from the open to the close position per the instructions of Q0-2. *Valve position is determined by observing the valve position indicating lights located in the Control Room.

CORRECTIVE ACTION:

Sho"Uld either valve fail to meet the stroke time acceptance criteria, corrective action per Procedure Step 5.4.. 1 shall be taken.

COLD SHUTDOWN TESTING BASIS NUMBER 14 Proc No EM-09-02 Revision 14 Page 17 of 34 SYSTEM:

Engineered Safeguards CM-204-lAl VALVES:

CV-3029, CV-3030 CATEGORY:

B CLASS: 2 FUNCTION:

Containment Sump Isolation Valves TEST REQUIREMENT:

1.

IWV 3411; Test Frequency - Exercise at least once every three months.

BASIS:

Exercising CV-3029 and 3030 eliminates the suction source of more than one high and low pressure safety injection pumps.

During normal Power i Operations this testing places the plant in an action st~tement per Technical Specification 3.3.2, thus reducing the operational readiness of these systems. Therefore these valves will be exercised at cold shutdowns.

ALTERNATIVE TESTING:

Exercise each cold shutdown per Surveillance Procedure Q0-2, but not necessarily more frequently than once each quarter.

VERIFICATION METHOD:

The performance of these valves shall be determined by recording and trending the stroke time values from the close to the open position per the instructions of Q0-2.

Valve position is determined by observing the valve position indicating lights located in the Control Room.

CORRECTIVE ACTION:

Should either valve fail to meet the stroke time acceptance criteri.a, corrective action per Procedure Step 5.4.1, shall be taken.*

' \\

. **-. *-..... ~ '~ ;;. -

COLD SHUTDOWN TESTING BASIS NUMBER 15 Proc No EM-09-02 Revision 14 Page 18 of 34 SYSTEM:

Main Steam CM-205~1)

VALVES:

CV-0501, CV-0510 CATEGORY:

FUNCTION:

B CLASS: 2 These are the Main Steam Isolation Valves.

They shut on steam generator low pressure from a MSLB to limit the PCS cooldown rate and the resultant reactivity insertion. Technical Specifications specify a maximum closing time of five seconds.

TEST REQUIREMENT:

I.

BASIS:

IWV 3521; Test Frequency - Exercise at least once every three months.

These valves cannot be exercised during normal plant operation sinle a full-stroke exercise results in loss of steam flow..;.to the turbine creat-adverse transients and a resulting reactor trip *. A. partial stroke exercise is not practical during power operations since these valves fu stroke on initiation of a close signal. These valves can be exercised during hot or cold shutdown periods.

ALTERNATIVE TESTING:

Exercise each hot or cold shutdown per GOP-02, but not:necessarily more frequently than once each quarter.

VERIFICATION METHOD:

  • The performance of these valves shall be determined by recording and trendi~g stroke time values from the open to the close position per the instructions of GOP-02.

Valve position is determined by observing the valve posi'tion indicating lights located in the Control Room *

  • ~v_..
  • r CORRECTIVE Aft:~d,t;

/

Should either valve fail to meet the st~oke time'acceptance criteria, corrective-action per Procedure Step 5. 4. I sha 11 be, taken.

COLD SHUTDOWN TESTING BASIS NUMBER 16 Proc No EM-09-02 Revision 14 Page 19 of 34 SYSTEM:

Service Water CM-208-lAl VALVES:

CV-0823, CV-0826 CATEGORY:

FUNCTION:

B CLASS: 3 Service water discharge from Component Cooling Heat Exchanger Isolation Valve.

TEST REQUIREMENT:

BASIS:

IWV-3411; Test Frequency - Exercise at least once every three months.

~

Exercising CV-0823 and 0826 during normal operation requires i~ola~ng the cooling* water (Service Water Supply} from the Component Cooling Heat Exchangers (E54-A and E54-B}.

The resulting loss of cooling water£would cause thermal-shock to the heat exchangers and after repeated tests eventually damage the tube to tube sheet welds *.

These valves can be exercised during cold shutdowns.

The primary coolant pumps are not in service.

ALTERNATIVE TESTING:

Exercise each cold shutdown per Surveillance Procedure Q0-06, but not necessarily more than once each quarter.

VERIFICATION METHOD:

The performance of these valves shall be determined by recording and trendi~g stroke time values in the open and close direction per the ins~ructions of Q0-6.

Valve position is determined by observing the valve posltion indicating lights located in the Control Room.

.::.:.~....

CORRECTIVE *'ACTION:

/

Should either valve fail to meet the stroke time'.acceptance criteria, corrective action per Procedure Step 5.4.1 shall be taken.

COLD SHUTDOWN TESTING BASIS NUMBER 17 Proc No EM-09-02 Revision 14 Page 20 of 34 SYSTEM:

Component Cooling *cM-209-ll VALVES:

CV-0910, CV-0911, CV-0940 CATEGORY:

A CLASS: 2 FUNCTION:

Isolation valves for component cooling supply and return from containment.

TEST REQUIREMENT:

1.

IWV-3411; Test Frequency - Exercise at least once every three months.

BASIS:

Exercising the above valves during normal operation* results in los~of cooling water flow-to the primary coolant pump seals. The interruption of flow would cause* failure of the pump seals.: and* eventual pump beari~g failure. This test is impractical to perform.. while :the*primary coolant pumps are in service. This testing can be*performed'during cold shutdo\\o!l when the primary. co.olant pumps are not in se.rv:tce.

ALTERNATIVE TESTING:

Exercise during cold shutdowns from the open to close position per Surveillance Procedure Q0-6, but not necessarily mo.re frequently than once each quarter.

Leak test each refueling outage per Surveillance Procedure R0-32.

VERIFICATION METHOD:

The performance of these valves shall be determined by recording and trending stroke time values in the close directton per the instructions of Q0-6.* _Valve position is determined by observing the valve* position ind,ic~ting lights. located in the Control Room-.

CORRECTIVE A~TION:

~--

,. \\:

Should any valve fail to meet the stroke/iime ac~eptance criteria, corrective_ a~tion per Procedure Step 5'.4.1 shall* b.e t~ken~:

COLD SHUTDOWN TESTING BASIS NUMBER 18 Proc No EM-09-02 Revision 14 Page 21 of 34 SYSTEM:

Component Coolinq CM-209-3)

VALVES:

CV-0945, CV-0946 CATEGORY:

FUNCTION:

8 CLASS: 3 Component cooling water inlet to component c.oo 1 i ng heat exchanger isolation valve.

. TEST REQUIREMENT:

1.

IWV-3411; Test Frequency - Exercise at least once every three months.

BASIS:

Exercising CV-0945 and CV-0946 requires isolating the component co~ing water from heat exchangers E54A, E548.

During normal operation the) resulting loss of cooling water would cause thermal-shock to the heat exchangers and eventually damage the tube to tube }heet welds. These valves can be exercised at cold shutdowns when the heat exchangers are not in service.

ALTERNATIVE TESTING:

Exercise valves to the -0pen and close position per Surveillance Procedure Q0-6 each cold shutdown, but not necessarily more frequently than once each quarter.

VERIFICATION METHOD:

The performance of'.these valves shall be determined by recording and trending stroke time values in the close direction per the instructions of Q0-6.

Valve position is determined by observing the valve position indi.cating lights located in the Control Room.

CORRECTIVE ACTlON:

.._~.. ~~-* *:

Shola'hfeither; valve fail to meet the strok~ time acceptance criteria, corrective action per Procedure Step 5. 4.. -1 sha 11

~e taken.

\\

\\

COLD SHUTDOWN TESTING BASIS NUMBER 19 Proc No EM-09-02 Revision 14 Page 22 of 34 SYSTEM:

HVAC CM-218-2)

VALVES:

CV-1805, CV-1806, CV-1807, CV-1808 CATEGORY:

A CLASS: 2 FUNCTION:

Containment Purge Air Exhaust Isolation Valves TEST REQUIREMENT:

1.

IWV 3411; Test Frequency - Exercise at least once every three months.

BASIS:

Exercising the above valves during power operation is not practica~ since these valves are normally closed to provide containment integrity. J Although the above valves do not change position to perform their ~

containment isolation function, they may be open during refueling ~nd be required to close to maintain containment (i.e. refuel i'ng accident}.

These valves can be exercised during cold shutdowns whe.n containment integrity is not required.

ALTERNATIVE TESTING:

Exercise valves to position required to fulfill their safety function each cold shutdown per Q0-06, but not necessarily more frequently than once each quarter.

VERIFICATION METHOD:

The performance of these valves shall be determined by recording and trending stroke time values in the close direction per the instructions of Q0-6. _Valve position is determined by observing the valve position inqicating lights located in the Control Room.

CORRECTIVE ACTION:

Should *either valve fail to meet the str6ke time.acceptance criteria, corrective action per Procedure Step s*. 4.1 sha 11 be taken.

COLD SHUTDOWN TESTING BASIS NUMBER 20 Proc No EM-09-02 Revision 14 Page 23 of 34 SYSTEM:

Service Water CM-208-lBl VALVES:

CV-0824 and CV-0847 CATEGORY:

B CLASS: 2 FUNCTION:

Containment Service Water Supply/Return Isolation Valves.

TEST REQUIREMENT:

1.

IWV-3411; Test Frequency - Exercise at least once every three months.

BASIS:

Exercising CV-0824 and CV-0847 during normal power operations isolates cooling water flow to the containment air coolers.

Loss of cooling flow results in an immediate action statement per the Technical Specifications.

These valves can be exercised during cold shutdowns when the containment air coolers are not in service.

ALTERNATIVE TESTING:

Exercise to the close position per Surveillance Procedure Q0-6 each cold shutdown, but not ne~essarily more frequently than once each quarter.

VERIFICATION METHOD:

The performance of these valves shall be determined by recording and trending stroke time values in the close direction per the instructions of Q0-6.

Valve position is determined by observing the valve position indicating lights located in the Control Room.

CORRECTIVE ACTIDN:

Should either valve fail to meet the stroke time acceptance criteria, corrective action per Procedure Step 5.4.1 shall be taken.

  • ~~*~.!. - *. -** :*~*-*-- -.

COLD SHUTDOWN TESTING BASIS NUMBER 21 Proc No EM-09-02 Revision 14 Page 24 of 34 SYSTEM:

Service Water (M-208-lA)

VALVES:

CV-0825 and CV-0878 CATEGORY:

FUNCTION:

B CLASS: 3 Safeguards Air Cooler Isolation valves for service water supply and return.

TEST REQUIREMENT:

1.

IWV-3411; Test Frequency - Exercise at least once every three months.

BASIS:

-1.

~~-.

Exercising CV-0825 and CV-0878 during normal power operations isol~tes cooling water flow to the safeguards air cooler.

Los*s of cooling flow results in an imediate action statement per the Technicarspecifications.

These valves can be exercised during cold shutdowl)S,~h.en t_he safeguard air cooler is not in service.

ALTERNATIVE TESTING:

~:

Exercise to the open position per Surveillance Procedure Q0-6 each cold shutdown, but not necessarily more frequently than once each quarter.

VERIFICATION METHOD:

The performanc;e. -of1 these valves shall be determined. by,recording and trending stroke.ti)ne values in the open and close direction per the instructions *of Q0-6.

Valve position is determined by observing the valve position indic~~ing lights located in the Control Room.

CORRECTIVE ActlbN:

ShGdl~d* either valve fail to meet the stroke time _accep.tance criteria, corr~ctive action per Procedure Step 5.4.1 shall be taken.

\\ -

\\

COLD SHUTDOWN TESTING BASIS NUMBER 22 Proc No EM-09-02 Revision 14 Page 25 of 34 SYSTEM:

Primary Coolant System CM-201-2)

VALVES:

PRV-1042B and PRV-1043B CATEGORY:

FUNCTION:

B CLASS: 1 The power operated relief valves (PORV's) provide primary system overpressure protection from (1) a charging/letdown imbalance, (2) the start of a high pressure safety injection (HPSI) pump and (3) initiation of forced circulation in the PCS when the steam generator temperature is

  • higher than the PCS temperature.

Analysis shows that when three charging pumps are operating and letdown is isolated and a spurious HPSI occurs, the PORV setpoints ensures that 10CFR50, Appendix G pressure limits will not be exceeded.

Above 430° F, the pressurizer safety valves prevent 10CFR50, Appendix G limits from being exceeded by a charging/letdown imbalance.

The requirement that steam generator temperature be less than or equal to PCS temperature when forced circulation is initiated in the PCS ensures that an energy addition caused by heat transferred from a secondary system to the PCS will not occur. This requirement applies only to the initiation of forced circulation (the start of the first primary coolant pump) with one or more of the PCS cold leg temperatures less than 450° F.

Requiring the PORV's to be operable when the shutdown cooling system is not isolated (M0-3015 and M0-3016 open) from the PCS ensures that the shutdown cooling system will not be pressurized above its design limits.

TEST REQUIREMENT:

1.

IWV-3411;. Test Frequency - Exercise at least once every three months.

BASIS:.

Opening these valves during power-operations creates the possibility of the PCS loss of coolant accident (LOCA) w~th a single failure of the associated PORV block valve. Also, per. Technical Specification 3.1.8.1, the PORV's are not required operable while the plant is at power operations.

ALTERNATIVE TESTING:

Exercise to the open position per Surveillance Procedure Q0-6 each c~ld shutdown, but not necessarily more frequently than once each quarter.!

Cold shutdown testing shall be performed by cycling the valve using t:he solenoid actuator.

VERIFICATION METHOD:

COLD SHUTDOWN TESTING BASIS NUMBER 22 (Continued)

Proc No EM-09-02 Revision 14 Page 26 of 34 The performance of these valves shall be determined by recording and trending stroke time values in the open and close direction per the instructions of Q0-6.

Valve position is determined by observing the valve position indicating lights located in the Control Room.

Acceptable operation shall be indicated when the valve successfully moves from the closed to the open position.

No stroke time limit shall be applied (see Relief Request 15).

'CORRECTIVE ACTION:

Should either valve fail to stroke, corrective action per Procedure Step 5.4.1 shall be taken, and an alternative vent path established per the requirements of Technical Specification 3.1.8.1.

\\

COLD SHUTDOWN TESTING BASIS NUMBER 23 Proc No EM-09-02 Revision 14 Page 27 of 34 SYSTEM:

Main Feedwater System CM-207-lAl VALVES:

CV-0701, CV-0703, CV-0734 and CV-0735 CATEGORY:

FUNCTION:

B CLASS: 2 The steam generators are operated in parallel on the feedwater and on the steam sides.

Each generator has a three element controller with inputs of feedwater flow, steam flow (corrected for pressure) and downcomer level.

The Output of each controller when in automatic control is used to provide pneumatic signals to position the respective feedwater regulating control valve.

The larger value of the two signals provides a speed control signal to the main feedwater, turbine driven pumps.

When Plant power is between 5% and 25%, feedwater is automatically controlled by a single element controller monitoring steam generator downcomer level and i positioning the feedwater regulating bypass valves.

Four overrides~~are provided:

~

~

1.

When contacts in the steam dump permissive switch ~re actuated on a main turbine trip, feedwater regulating control valves are maintained in the position whtch existed prior to the switch activatidn. The feedwater pumps are then ramped down in speed to obtain a linear ramp flow decrease to 5% flow in 60 seconds following the trip.

2.

When an abnormally high steam generator level is sensed by an independent downcomer level sensor, a signal is sent to close the associated feedwater regulating contrdl valve and a control room alarm is annunciated.

3.

During low steam generator pressure< 500 psia, the main feedwater control valves and the-bypa,ss valves are closed automatically. The operator can manually take control of the bypass valves by isolating the low steam generator pressure signal using a key switch on the control panel.

4.

In order to limit Containment Pressure during the Main Steam Line Break to less;~h~n 55 psig the MFW regulating valves (CV-0701 and CV-0703) and bypass valves (CV-0734 and CV-0735) also close on containment high. __

prei$.UrJ! *ccHP) > 4 psig. A preliminary peak pressure calculation gfves acceptable results (pressure..s.. 55 psig). _Jhe operator can manually take control-of the bypass valves by isolati~g the Cont~inment High Pressure signal.

-:~-

COLD.SHUTDOWN TESTING BASIS NUMBER 23 (Continued)

Proc No EM-09-02 Revision 14 Page 28 of 34 Manual control of.the feedwater flow may be assumed at anytime to circumvent malfunction of components within the system.

When in manual control, the operator in the control room can:

1.

Position manually each feedwater regulating control valve,.

2.

Control speed of the two main feedwater pumps,

3.

Open or clos~ each feedwater stop valve and

  • 4.

Position manually each feedwater bypass regulating valve.

TEST REQUIREMENT:

BASIS:

Exercise quarterly to the close position per the requirements of ASME Section XI, Paragraph IWV-3412(a) and (b).

-~

~

?

Testing on a quarterly interval.during power operations would resuft in a portion of the feedwater system being out of servi~e for a minimum peri of time in the range of 12 to 32 seconds *.

The.actual time would be lon due to personnel reaction time and time required to perform procedure recordings. Results would be the following:

1.

Decrease in steam generator level possibly resulting in an Auxiliary Feedwater Actuation Signal.

2.

Thermal shock to the steam generator caused by the loss of feedwater and subsequent reinitiation.

3.

Variation i.n ~eact9r power caused by T 11ve* changes as. a resui t of steam generator level and temperature variat1ons.

Industry responses to NOMIS Report Request 90-04-081 and Network Message #3850 indicate all~respondents wMch test their feedwater regulating and bypass valves due so at po*e~ levels less than power operations.

f;~;~:~~~~.:.

'~ -._

\\ \\

  • >1 **

COLD SHUTDOWN TESTING BASIS NUMBER 23 {Continued)

Proc No EM-09-02 Revision 14 Page 29 of 34 ALTERNATIVE TESTING:

Exercise to the close position per Surveillance Procedure Q0-6 each cold shutdown, but not necessarily more frequently than once each quarter.

Cold shutdown testing shall be performed by cycling the valve using the normal actuation circuit.

VERIFICATION METHOD:

Full-stroke testing (open to close) shall be performed on the MFW regulating and bypass valves starting at the Palisades 90REFOUT.

The current design limit stroke time value used is 30 seconds and is conservatively based on operating history experience. A special test was performed in 1984 which indicated a 20 second stroke time. Testing in May 1990 as part of Facility Change package FC-906 indicates the following stroke times for the subject valves:

"'_~

VALVE TIME (OPEN TO CLOSED)

CV-0701 16.13 SEC

~~*

CV-0703 15.99 SEC CV-0734 6.19 SEC CV-0735 7.13 SEC Based on this data there is a 13.87 to 23~81 second margi~ to the design limit of 30 seconds. These valves were added to the IST program in July 1990.

The performance of these valves shall be determined by recording and trending stroke time values in the close direction per the instructions of Q0-6.

Valve position is determined by observing the valve position indicating lights ~ocated in the Control Room.

Acceptable operation shall be indicated when the valve successfully moves to the closed position within the specified stroke time limits.

CORRECTIVE A~TION:

Should any valve fail to stroke, corrective action per Procedure Step-75.4.1 shall be taken.

~ -

--~

COLD SHUTDOWN TESTING BASIS NUMBER 24 Proc No EM-09-02 Revision 14 Page 30 of 34 SYSTEM:

Primary Coolant System (M-201-2)

VALVES:

M0-1042A and M0-1043A CATEGORY:

FUNCTION:

A CLASS: 1 Power Operated Relief Valve (PORV} Block Valves M0-1042A and M0-1043A provide isolation capability for the PORV system.

The block valves provide a flow path for feed and bleed of.the* pressurizer.

TEST REQUIREMENT:

1.

BASIS:

IWV-3411; Test Frequency - Exercise at least once every three months.

  • ..:~.

Exercising M0-1042A or M0-1043A while the Primary Coolant System (P~S} is not depressurized will result in the respectjve PORV being opened by the increased inlet pressure to the PORV.

This:'will oause depressurization the PCS and possible damage to downstream eqyipment frqm.the excessive steam flow past the PORV and Block Valves; This test is impractical to perform during normal operations. These valves will be exercised during cold shutdowns when the P,CS is depressurized.

ALTERNATIVE TESTING:

._ ~-

Exercise to the open position per Surveillance Procedure QQ-06 each cold shutdown, but not necessarily more frequently than once each quarter.

VERIFICATION METHOD:

The.*performance of these valves shall be determined.-..by recording and tr~d;fng stroke time values in the open and close direction per the instructions of Q0-6. *Valve position is.determined by observing the--valve pos;tfon indicating lights located in the,Control Room.

Acceptable operation shall be indicated when the valve succe~sfully moves from the closed to ~he open position.

CORRECTIVE ACTION:

Should either valve fail to stroke, corrective action per Procedure Step 5.4.l shall be taken, and an alternative vent path established per the requirements of Technical Specification 3.1.8.1.

.~ !"';

  • 1 COLD SHUTDOWN TESTING BASIS NUMBER 25 Proc No EM-09-02 Revision 14 Page 31 of 34 SYSTEM:

Chemical and Volume Control {M-202-lAl VALVES:

M0-2160 CATEGORY:

FUNCTION:

B CLASS: 2 M0-2160 is the Safety Injection and Refueling Water {SIRW) tank to charging Pump Suction isolation valve.

M0-2160 opens to provide an alternate source of boration to the charging pumps suction. This flow path is gravity feed.

TEST REQUIREMENT:

IWV-3411; 'Test Frequency - Exercise at 1 east once every three months.

BASIS:

~

~!".:

Exercising M0-2160 open duririg nrirmal plant operation would. result in a significant reactivity change from the injection of concentrated boric acid into the PCS.

The resulting reactor power/PCS temperature excursion could cause a reactor trip. During hot shutdown, since significant PCS boration does not occur, exercising M0-2160 can result in the unnecessary generation of large quantities of radioactive waste, especially late in core life.

ALTERNATIVE TESTING:

Exercise during cold shutdown, but not necessarily more frequently than once each quarter,. as allowed by Procedure Step 5.2.Ll. Exercising shall be performed according to procedure Q0-6, "Cold Shutdown Valve Test Procedure {includes Containment Isolation Valves)".

VERIFICATION MEJHOD:

Ope~~~fl ity.of M0-2160 shall be determined by observing/recording stroke tim~;**;;from close to open *position. Valve position is. verified by obs*rving valve position indicating lights located in* the: c-ontrol-room.

/

CORRECTIVE ACTION:

\\,......

Should M0-2160 fail to meet the specified stroke tii'ne, corrective action as outlined in procedure EM 09-02, Step 5.4 *.1 shall be.taken and an alternate boration flow path established per Technical, Specification requirements 3.2.3.

-. -_-_::.-,. *:- >;.*/,-

    • *.. :~. -:..** -

COLD SHUTDOWN TESTING BASIS NUMBER 26 Proc ~o EM-09-02 Revision 14 Page 32 of 34 SYSTEM:

Chemical and Volume Control (M-202-lAl VALVES:

CK-CVC2141, CK-CVC2161, CK-CVC2171 CATEGORY:

c CLASS: 2 FUNCTION:

1.

To provide a flowpath from boric acid injection to suction of the charging pump.

TEST REQUIREMENT:

1.

IWV-3411; Test Frequency - Exercise at least one every*three months.

BASIS FOR RELIEF:

  • i,

-~~

The test flowpath necessary to exercise these valves invo.lves operating the Concentrated Boric Acid Pumps.

This would result in the injectJon of concentrated Boric Acid in to the suction of the Charging Pumps, ana subsequently into the PCS.

The resulting reactor power/PCS

  • temperature/pressure transient could cause a* reactor trip. During hot shutdown, since significant PCS boration does not occur, exercising thes valves can result in the unnecessary generation of large quantities of radioactive waste, especially late in core life.

ALTERNATIVE TESTING:

Exercise during cold shutdown, but not necessarily more frequently than once each quarter as allowed by Procedure Step 5.2.1.1. Exercising shall be performed according to System Operating Procedure SOP-2A, "Chemical and volume Control System Charging and Letdown; Concentrated Boric Acid".

VERIFICATION METHOD:

Verification of valve performance shall occur through the monitoring of degradation via System Operating Procedure SOP-2A, "Chemical and Volume Contiol System Charging and Letdown:. Concentrated Boric Acid".

Exercising the valves per this procedure wtl l verify the ability of these valves-to pass 68 gpm.

CORRECTIVE ACTION:

Should any valve fail to meet fullstroke flow rate for stroke flow rate for check valve requirements, corrective action per Procedure Step 5.4.1 shall be taken.

"-.-~.......

  • COLD SHUTDOWN TESTING BASIS NUMBER 27 Proc No EM-09-02 Revision 14 Page 33 of 34 SYSTEM:

Safety Injection (M-203-2)

VALVES:

CK-ES3104, CK-ES3119, CK-ES3134, CK-ES3149 CATEGORY:

AC CLASS: 1 FUNCTION:

1.

To provide LPSI and HPSI flowpath to the PCS.

2.

To prevent backflow of PCS, SIT, and HPSI or LPSI.

TEST REQUIREMENT:

1.

IWV-3521; Test Frequency - Exercise at least once every three months to position required to fulfill function (closure test)

BASIS FOR RELIEF:

These valves perform a reverse flow stoppage function to prevent ba~kflow of PCS, SIT, and HPSI or LPSI into the respective £upply headers.

Closure verification can only be performed by isolating and:9raining the header lines immediately upstream of these check valves. This can only be accomplished by making a containment entry to isolate the line and drain it for leakage verification.

ALTERNATIVE TESTING:

Closure verification shall be performed at Hot Shutdown, but not necessarily more frequently than once each quarter, as allowed by system operating procedure S0-9, "Primary Coolant System Pressure Isolation Check Valves".

VERIFICATION METHOD:

Vertfi~ation of valve leakage shall occur via S0-9. This procedure involves an acceptance criteria of less than.75 gpm. leakage.

CORRECTIVE ACTION:

Should these valves fail to meet their minimum leakage requirements, corrective-action as outlined in Procedure Step 5.4.1 shall be taken.

~--.

COLD SHUTDOWN TESTING BASIS NUMBER 28

. ~..., '.. -. ":

Proc No EM-09-02 Revision 14 Page 34 of 34 SYSTEM:

Service Water (M-208-lAl VALVES:

CV-0821, CV-0822 CATEGORY:

B CLASS: 3 FUNCTION:

1.

To provide temperature control of component cooling water by regulating service water flow*out of the CCW heat exchanger.

TEST REQUIREMENT:

1.

IWV-3411; Test Frequency - Exercise at least once every three months.

BASIS FOR RELIEF:

-h These valves are used to throttle the service water flow through thl CCW Heat Exchangers. Stroke Testing these valves to the closed position could cause thermal stress to the CCW heat exchangers, leading to possible failure of the tube to tube sheet welds. ThiS is f>f greater concern during winter months when service water is coldest* and' throttled to a minimum.

ALTERNATIVE TESTING:

Exercise during cold shutdown, but not necessarily more:"frequently than once every three months as allowed by Procedure Step 5.2.1. Exercising shall be performed according to Q0-6, "Cold Shutdown Te.st Procedure (Includes Contai:nment Isolation Valves).

The thermal*loa5J:on the CCW Heat Exchanger is* much 11ower during co 1 d shutdown a l1 owtng service water fl ow to be interrupted with no detrimental effects.

VERIFICATION METHOD:

~

The~;P.erformance' of these valves shall be determined by recording and trending the.stroke times of these valves in the closed direction per the instrucUons of Q0-6.

Valve position is determined by observing th*e valve position indicating 1 ights located in the.. Control room*.*

\\

CORRECTION ACTION: -

_\\

  • '.*.'\\-.*

\\

.* *\\

Should those valves fail to meet their stroke time requirements, corrective action as outlined in Procedure Step 5.4.1 'shall be taken.

Proc No EM-09-02 Revision 14 Page 1 of 57 RELIEF REQUEST INDEX RRl:

Relief for Hot Leg HPSI Check Valves RR2:

Relief for Safety Injection Check Valves for Tanks T-82A, 8, C and D RR3:

Relief for Containment Spray Header Check Valves RR4:

Relief for HPSI System Check Valves RR5:

Relief for Redundant HPSI System Check Valves RR6:

Relief for Containment Sump Check Valves RR7:

Relief for SIRW Tank Check Valves RRS:

Relief for Individual HPSI Pump Check Valves RR9:

Relief for Containment Spray Pumps Check Valves RRlO:

Relief for Emergency Diesel Generator Check Valves RRll:

Relief for All Containment Penetration Valves RR12:

Relief for Component Cooling Isolation Check Valves to and from Radioactive Waste Evaporators RR13:

Relief for Component Cooling Water to East and West Check Valves RR14:

Relief for Various Fast Acting Valves RRlS:

Relief for PRY Valves RR16:

Relief for Check Valves Providing HPSI Flow to Loop #1 Hot Leg Injection Flow Path RR17:

Relief for all Applicable Check Valves Exercising Where Impractical RR18:

Relief for Auxiliary Feedwater Check Valve Closure Test RR19:

Relief for Containment Air Cooler Outlet Check Valves RR20:

Relief for Charging Line to Loop-2A Check Valve RR21:

Relief for Pressurizer Auxiliary Spray Check Valve RR22:

Relief From Corrective Action/Plant Startup per, -IWV-3417b and IWV-3523

s:

'11::,

RR23:

Relief From Test Frequency/Per IWV-3411 and IWV-3422.

~

I Ct-1 RR24:

Relief From Test For Condensate Demineralizer System Check Valve

~

RR25:

RR26:

RR27:

Relief From Stroke Time Testing For Auxiliary Feedwater Flow Control Valves 1

Relief for Chemical and Volume Control System Check Valves Relief for Service Water System Check Valves I

C>

D 0

0

Proc No EM-09-02 Revision 14 RELIEF REQUEST BASIS NUMBER 1 SYSTEM:

Engineering Safeguards (M-201-ll VALVES:

CK-3410 CATEGORY:

c CLASS: 1 FUNCTION:

Page 2 of 57

1.

Prevent PCS back leakage into the Hot Leg High Pressure Safety Injection (HPSI} lines.

2.

To pass flow from the HPSI system to the.Hot Leg Injection.

TEST REQUIREMENT:

I.

IWV-3521; Test Frequency - Exercise at least once every three month.s.

BASIS.FOR RELIEF:

Full-stroke testing during hot plant conditions is.not performed for the following reasons:

1.

A full flow test path is not available during plant conditions greater than cold shutdown (reactor vessel head removed or-equal} due to nozzle thermal shock considerations.

2.

Full flow testing cannot be performed during cold shutdowns (reactor vessel head installed} due to Technical Specification HPSI pump operability 1imitations.

ALTERNATIVE TESTING:

Check CK-3410 shall be tested as follows:

1.

CK-3410 shall-be full-stroke exercised during each refueling outage according to Inservice Test Procedure R0-65, "HPSI/RHPSI Check Valve Test*.

  • System. fl ow and pressure is recorded and.. trended to determine valve performance.

RELIEF REQUEST BASIS NUMBER 1 (Continued)

Proc No EM-09-02 Revision 14-Page 3 of 57

2.

CK-3410 is additionally partial stroke exercised during each cold shutdown in accordance with Surveillance Procedure Q0-8B.

This test partially strokes CK-3410 open using the charging pumps to pass flow to the Primary System Drain tank.

QUALIFICATION PROGRAM:

None INSTRUMENTATION DESCRIPTION:

The instruments used are identified in the test document.

Each instrument used to verify adherence to acceptance criteria is maintained in accordance with Palisades Administrative Procedures.

Each instrument is further identified on the Equipment Data Base as "Q" or "B" in the "X" field of the Q-List lnterpr-etation.

BASELINE DATA:

Baseline data for. CK-3410 was obtained via Preoper.ational Test Procedure 7502-502Q.

This procedure was performed in October and November of 1981 as part of Facility Change FC-502~: Flow was provided by the Low Pressure Safety Injection Pumps and flows of 300 gpm with the PCS depressurized were recorded.

ACCEPTANCE CRITERIA:

Inservice Testing shall be performed during refueling outages with, the Reactor Vessel Head removed.

A test shall be considered acceptable when observed Hot Leg Injection flow for each path is equal to or greater than 250 gpm.

/

Proc No EM-09-02 Revision 14 Page 4 of 57 RELIEF REQUEST BASIS NUMBER 2 SYSTEM:

Engineering Safeguards {Safety lnjection/M-203-1)

VALVES:

CK-3102, CK-ES3117, CK-ES3132, CK-ES3147 CATEGORY:

c CLASS: 1 FUNCTION:

1.

Prevent PCS leakage into Safety Injection Tanks T-82A, B, C and D.

2.

To pass flow from the Safety Injection Tanks to the PCS.

TEST REQUIREMENT: *

. I.

IWV-3521; Test Frequency - Exercise at least once *every *three month_.~~

'ii BASIS FOR RELIEF:

-'.~

.~

The above check valves cannot be full or partial stroke exercised. ti during normal power operations since. exercising the valves-*open requires discharging highly borated water from::the, Safety< Injection Tanks (SIT) to the Primary Coolant System {PCS).-. This="test path is not possible s.ince.the PCS is normally at a pressure* of approximately 2500 psig and the normal pressure of the SIT is *'approximately 200 psig.

ALTERNATIVE TESTING:

I.

2.

Safety Injection Tank Discharge check valves. shall. be~tested as follows:

. = _!l.

During each hot shutdown, these valves shall be part stroke tested according to Inservice Test Procedure QO-SC, "ESS Check Valve OperabjJity Test and High Pressure Safety Injection Flow Indicator Verification {Hot Shutdown).

EaJi~:--~~fueling outage these check valves shall be full-stroke exercised in accordance with Surveil 1 ance Procedure R0-105, "Full Flow Test of Safety Injection Bottle che.c~ valve~", or

RELIEF REQUEST BASIS NUMBER 2 (Continued)

Proc No EM-09-02 Revision 14 Page 5 of 57

3.

During each refueling outage, a minimum of one check valve shall be disassembled and freedom of disc motion verified per Inservice Test Procedure RM-114, "Disassembly, Verification of Disc Motion and Reassembly of Safety Injection Tank 12" Check Valves".

QUALIFICATION PROGRAM:

None

  • INSTRUMENTATION DESCRIPTION:

The instruments used are identified in the test document.

Each instrument used to verify adherence to acceptance criteria is maintained in accordance with Palisades Administrative Procedures.

Each instrument is further identified o~ the Equipment Data Base a$

"Q" or "B" in the "X" field of the Q-List Interpretation.

~

.i BASELINE DATA:

Safety injection check valves were full-stroke tes~ed under full system pressure and level conditions during the performance of Preoperational Test Number 12 (Preop #12). This test verified the ability of the installed system configuration to pass flow.

Full flow verification maybe performed each refueling outage via procedure R0-105 or freedom of disc motion maybe verified by disassembly/inspection per RM-114 and partial stroke testing per QO-SC.

ACCEPTANCE CRITERIA:

For RM-114 the fol:lowing shall occur:

1.

Upon removal of the bonnet the disc will demonstrate freedom of motion_ through its full-stroke range.

Fo~.c.QO-SC the following shall occur:

1.

Indf~ation of positive flows greater than 20 gpm shall constitute an acceptable test.

For RO-lOS-the fol_lowing shall occur:

1.

Indication of positive full flow greater than 3500 gpm constitutes an acceptable test.

.. : '.. :_ ~,

Proc No EM-09-02 Revision 14 Page 6 of 57 RELIEF REQUEST BASIS NUMBER 3 SYSTEM:

Engineering Safeguards (Containment Spray/M-203-2)

VALVES:

CK-ES3216, CK-ES3226 CATEGORY:

c CLASS: 2 FUNCTION:

1.

Prevent back flow from Containment Spray Header.

2.

Provide a containment spray flow path.

TEST REQUIREMENT:

I.

I.

IWV-3521; Test Frequency - Exercise at least once every three month~.

IWV-3522; Exercising Procedure - Exercise to the full open position{

BASIS FOR RELIEF:

To full-stroke exercise the containment spray check valves requires initiating the containment spray system and, spraying down the containment. This test is not practical ~uring.any mode of operation.

ALTERNATIVE TESTING:

These check valves are disassembled and inspected (including a manual full-stroke exercise} fn accordance with Engineering Manual Procedure EM-29-02, "Preventative Maintenance Program for Check Valves" in lieu of full flow testi~g. This method is in compliance with Generic Letter 89-04.

In addition, these valves are partial stroke exercised every three months-in accordance with Procedure Q0 "Containment Spray and LPSI Che'ck:~alve Test.

QUALi FICATIC>N'.'PROGRAM:

None

\\.

. ~ r RELIEF REQUEST BASIS NUMBER 3 (Continued)

Proc No EM-09-02 Revision 14 Page 7 of 57 INSTRUMENTATION DESCRIPTION:

The instruments used are identified in the test document.

Each instrument used to verify adherence to acceptance criteria is maintained in accordance with Palisades Administrative Procedures.

Each instrument is further identified on the Equipment Data Base as "Q" or "B" in the "X" field of the Q-List Interpretation.

BASELINE DATA:

CK-3216 and CK-3226 were initially tested via Preoperational Test Procedure Number 12. Test conditions were approximately 300 gpm flow at 260 psig pressure. These readings are considered the baseline performance parameters obtained when the plant was in new condition.

Inservice testing is performed per Q0-10 under approximately the sa~e conditions. These actions are considered sufficient to monitor forl valve degradation.

J ACCEPTANCE CRITERIA:

For procedure Q0-10, indication of positive*flow*const~tutes an acceptable part stroke test.

At each disassembly the valves will be* manually exercised to verify full-stroke capability. Also the disassembled valve will be inspected to ensure the internals are structurally sound (no loose or corroded parts).

\\

\\

\\

~* -. '

c-

' ~

Proc No EM-09-02 Revision 14 Page 8 of 57 RELIEF REQUEST BASIS NUMBER 4

  • SYSTEM:

Engineering Safeguards CHPSI/M-203-21 VALVES:

CK-ES3104, CK-ES3119, CK-ES3134, CK-ES3149 CATEGORY:

AC CLASS: 1 FUNCTION:

1.

Prevent back leakage of PCS/SI tank water into the HPSI System~

  • 2.

Provide a flow path for HPSI into the PCS.

TEST REQUIREMENT:

1.

IWV-3521; Test Frequency - Exercise at least once every three months.

BASIS FOR RELIEF:

These check valves cannot be full-stroke exercised during normal power operation since the test path required to stroke open the check valves requires injecting highly borated water inte the Primary Coolant System (PCS) which would result in a react-ivity change power reduction and possibly a pressure/temperature transient. This test flowpath is not available during normal operations since the PCS is at a greater pressure than the HPSl/RHPSI pump discharge.

In addition, the* potential for an intersystem LOCA would be created if any check valve-should fail, due to PCS operating pressure being greater than HPSI system design pressure. Testing at any plant

  • condition greater than cold shutdown (reactor vessel head removed or equal) will result in thermal shock to the injection nozzles.

Full-stroke testing is not possible during cold shutdown periods due to Technical Specification 3.3 pump operability limitations below 260.F (Low Temperature Overpressurization - 10 CFR 50 Appendix G).

ALTERNATIVE. T~STING:.

Th~~HPSI check valves shall be tested as follows:

-.~¥'--~.

I.

Duririg*cold shutdowns each valve shall b<<{part stroke tested per Inservice Test Procedure QO-BB, "ESS Check Valve.Operability Test and High Press*ure Safety Injection Flow Indicator Verification (Cold Shutdown)".

. - ~.

RELIEF REQUEST BASIS NUMBER 4 (Continued)

Proc No EM-09-02 Revision 14 Page 9 of 57

2.

During refueling outages (rector vessel head removed or equivalent),

these check valves shall be full-stroke tested per Inservice Test Procedure R0-65, "HPSI/RHPSI Check Valve Test".

QUALIFICATION PROGRAM:

None INSTRUMENTATION DESCRIPTION:

The instruments used are identified in the test document.

Each instrument used to verify adherence to acceptance criteria is maintained in accordance with Palisades Administrative Procedures.

Each instrument is further identified on the Equipment Data Base as "Q" or "B" in the "X" field of the Q-List Interpretation.

-.ii BASELINE DATA:

HPSI check valves were initially tested via Preoperational Test

~

Procedure Number 12. Observed parameters were greeter, than 250 gpm flow rate at pressures of approximately 1000 psig. These values were obtained when the plant was in new condition. Values are reconfirmed during refueling outages via R0-65.

Between refueling outages the check valves are part stroke tested during cold shutd9wns ~er QO-SB.

These actions are sufficient to monitor for degradation in the subject valves.

ACCEPTANCE CRITERIA:

When testing per R0-65, recorded flow rates greater than 250 gpm constitutes an acceptable full-stroke test.

When testing per QO~aB, recorded flow rates greater than 35 gpm constitute an acceptable part stroke test

  • Proc No EM-09-02 Revision 14
  • Page 10 of 57 RELIEF REQUEST BASIS NUMBER 5 SYSTEM:

Engineering Safeguards CHPSI/M-203-2)

VALVES:

CK-ES3250, CK-ES3251, CK-ES3252, CK-ES3253 CATEGORY:

c CLASS: 1 FUNCTION:

1.

Prevent back leakage of PCS/SI tank water into the Redundant HPSI System.

2.

Provide a flow path* for Redundant HPSI into the. PCS.

TEST REQUIREMENT:

1.

IWV-3521; Test Frequency - Exercise at least once every three mont~s.

-*~.:.

BASIS. FOR RELIEF:

~

~-

These check valves cannot be ful 1-stroke ~xercise~ during normal power operation: sjnce the test path required~-to strQke.open the check valves requires injecting highly borated-water into-the Primary Coolant System (PC_S) which would result in a-reactivi,ty' change power reduction* and possibly a pressure/temperature transient-.,. This test flow path is not available during normal operations since the PCS is at a greater pressure than the HPSI/RHPSI pump discharge.

In addition, the potential for an intersystem LOCA would be created in any check valve should fail, due to PCS operating pressure being greater than HPSI system design pressure. Testing at any plant condition* greater thancold shutdown (reactor vessel; head removed or equa 1) will re_sulti -j n therma 1 shock to the inject ion' nozzles.

Full-stroke, testing is not possible during cold shutdown-periods due to Tec~nical Specification 3.3 pump operabilJty 1 imitatoions below 260:!f: (Low Temperature Overpressurization - 10 CFR 50 Appendix G).

-~-

~---;.-

ALTERNATIVE TESTING:

RELIEF REQUEST BASIS NUMBER 5 (Continued)

Proc No EM-09-02 Revision 14 Page 11 of 57 The Redundant HPSI check valves shall be tested as follows:

1.

During cold shutdowns each valve shall be part stroke tested per Inservice Test Procedure Q0-8B, "ESS Check Valve Operability Test and High Pressure Safety Injection Flow Indicator Verification (Cold Shutdown)".

-2.

During refueling outages (rector vessel head removed or equivalent),

these check valves shall be full-stroke tested per Inservice Test Procedure R0-65, "HPSI/RHPSI Check Valve Test".

QUALIFICATION PROGRAM:

None INSTRUMENTATION DESCRIPTION:

The instruments used are identified in the test document.

Each instrument used to verify adherence to acceptance criteria is maintained in accordance with Palisades Administrative Procedures.

Each instrument is further identified on the Equipment Data Base as "Q" or "B" in the "X" field of the Q-List Interpretation. -

BASELINE DATA:

Redundant HPSI check valves were initially tested via Preoperational Test Procedure Number 12. Observed parameters were greater than 250 gpm flow rate at pressures of approximately 1000 psig. These valves were obtained when the plant was in new condition. Values are reconfirmed during refueling outages via R0-65.

Between refueling outages the check valves are part stroke tested during cold shutdowns per Q0-8B.

These actions are sufficient to monitor for degradation in the-subject valves.

ACCEPTANCE CRITERIA:

When testing per R0-65, recorded flow rates greater than 250 gpm constitutes an acceptable full-stroke test.

When testing per Q0-88, recorded flow rates greater than 35 gpm constitute an acceptable part stroke test.

Proc No EM-09-02 Revision 14 RELIEF REQUEST BASIS NUMBER 6 Page 12 of 57 SYSTEM:

Engineering Safeguards CM-204)

VALVES:

CK-3166, CK-3181 CATEGORY:

c CLASS: 2 FUNCTION:

1.

Prevent back flow of water from the SIRW tank into containment sump.

2.

To pass flow from the containment sump to the suction of the Engineering Safeguards pumps.

TEST REQUIREMENT:

1.

IWV-3521; Test Frequency - Exercise at least once every three mont~~*

2.

IWV-3522; Exercising Procedure ~ Exercise to the full open positiori.~

BASIS FOR RELIEF:

To full-stroke exercise the Containment sump discharge check valves requires initiating an ESS pump and pumping containment to the SIRW tank to verify adequate flow is achieved. This testing is.

impractical to perform during any mode of operation due to the amount of radwaste generated and the extensive filtering of the SIRW tank necessary to reestablish water chemistry requirements.

Using any other test path to perform this full-stroke test would require removing from service one of the ESS pump suction headers.

This action would not be permitted per Technical Specifications during power operations.

/

ALTERNATIVE TESTING:

RELIEF REQUEST BASIS NUMBER 6 (Continued)

Proc No EM-09-02 Revision 14 Page 13 of 57 These check valves are disassembled and inspected (including a manual full-stroke exercise) in accordance with Engineering Manual Procedure EM-28-02, "Preventative Maintenance Program For Check Valves" in lieu of full flow testing. This method is in compliance with Generic Letter 89-04.

In addition these valves are partial stroke exercised each cold shutdown in accordance with Inservice Test Procedure Q0-02, "Recirculation Actuation System and Containment Sump Check Valves".

QUALIFICATION PROGRAM:

None INSTRUMENTATION.DESCRIPTION:

The instruments used are identified in the test document.

Each instrument used to verify adherence to acceptance ~riteria is maintained in accordance with Palisades Administrative Procedures.

Each instrument is further identified on the Equipment Data Base as "Q" or "B" in the "X" field of the Q-List Interpretation.

BASELINE DATA:

Due to system configuration these valves have not been full-stroke tested since initial installation. Initial disassembly and inspection is tentatively scheduled for the 93 Refout (CK-ES3181) and 94 Refout (CK-ES3166).

This schedule is based on the priority achieved by apply EPRI NP-5479 "Application Guideli.ne for Check Valves in Nuclear Plants".

ACCEPTANCE CRITERIA:

Ind,;cation of positive flow per Q0-2 constitutes an acceptable part str~k~_test per Q0-2.

At ~~~h dhassembly the valves are manualJy exercised to v~rify full-stroke capability. Also the disassembled valve is inspected to ensure the _internals are structurally sound (no loo~e or corroded parts) *

\\

I

_~_.-. '

-,;*.. t'* *..
*. ~--

Proc No EM-09-02 Revision 14 RELIEF REQUEST BASIS NUMBER 7 Page 14 of 57 SYSTEM:

Engineering Safeguards (M-204-lB)

VALVES:

CK-ES3239, CK-ES3240 CATEGORY:

AC CLASS: 2 FUNCTION:

I.

Prevent back flow of containment sump water fnto the SIRW tank when SIS is in the recirculation mode (containment pressu~ized).

2.

Provide a flow path from the SIRW tank to the ESS pump suctions for safety injection flow.

TEST REQUIREMENT:

I.

2.

IWV-3521; Test Frequency - Exercise at least once every three month).

~

IWV-3522; Exercising Procedure - Exercise to the full open position~

BASIS FOR RELIEF:

Full flow exercising these valves with flow is notpossibl!! during any plant condition, other than during a full core offload_and when fuel pool cooling loads are low, for the following reasons.

Flow paths do not exist.which will pass the flow required'to achieve a full-strok~ test.

Valves cannot*be djsassembled, at times other than *a ful'l core offload wheti fuel pool cooling loads are low, because the.Y.cannot be isolated from the SIRW tank.

ALTERNATIVE TESJING:

Pa~i~:~troke quarterly per Inservice Test Procedures Q0-10, "Containment Spray and LPSI Check Valve Test" or Q0-16,: "Containment Spray.Pumps*. Additionally, part stroke i,s required for acceptable tests per Q0-16, Q0-19 and Q0-20.

1

/

\\.:, *:-

These check valves are disassembled and inspected'*{Jncluding a manual full-stroke exercise) in accordance with Engineering Manual Procedure EM-28-02, "Preventative Maintenance Program for Check Valves". This method is in compliance with Generic Letter 89-04. Disassembly shall occur nominally once per ten years when there is a ful1 core offload and when fuel pool cooling loads are acceptable.

QUALIFICATION PROGRAM:

None

INSTRUMENTATION DESCRIPTION:

RELIEF REQUEST BASIS NUMBER 7 (Continued)

Proc No EM-09-02 Revision 14 Page 15 of 57 The instruments used are identified in the test document.

Each instrument used to verify adherence to acceptance criteria is maintained in accordance with Palisades Administrative Proc~dures.

Each instrument is further identified on the Equipment Data Base as "Q" or "B" in the "X" field of the Q-List Interpretation.

BASELINE DATA:

These valves were initially full-stroke tested at 6000 gpm and

' 190 psig via Preoperational Test Procedure Number 12. Additionally, part stroke tests were performed using Preop #12 at conditions ranging from 300 gpm at 260 psig to 1500 gpm at 205 psig. These test values were obtained when the valves were in new condition.

Presently, part stroke testing is conducted on a quarterly basis a~

1000 gpm and 250 psi g.

Degradation would be shown by a change -in t flow rate or pressure. These test conditions provide adequate

  • ~

assurance of valve disc motion and is sufficient for monitoring for valve degradation.

Part stroke at lower flow rates is achieved**by Q0-16, Q0-19, and Q0-20.

Valves are included in the sample disassembly and inspection program EM-28-02.

ACCEPTANCE CRITERIA:

Observed test flow rates in the acceptable range for the Containment Spray pumps constitutes an acceptable test for the SIRW Tank discharge check valves.

At eac~ disassembly, the valves are manually exercised to verify full-stroke capability. Also, the disassembled valve is inspected to ensure* the internals are structurally sound* (no loose or corroded parts.)

-- --~-----------------------------

  • *-~1*"
  • :, *' -:**A~-- --r"*
  • .- -~ :*

~..

RELIEF REQUEST BASIS NUMBER 8 SYSTEM:

Engineering Safeguards CHPSI/M-204-1. IA. IBl Proc No EM-09-02 Revision 14 Page 16 of 57

~ I VALVES:

CK-3177, CK-3186 and CK-ES3411

~

~

I

~

~

~

CATEGORY:

FUNCTION:

c CLASS: 2 Valves pass flow from the HPSI pumps.

They also restrict back flow through the individual HPSI pumps.

The Technical Specifications do not specify a required maximum leak rate.

TEST REQUIREMENT:

I.

IWV-3521; Test Frequency - Exercise at least once every three months.

--~

- BASIS FOR RELIEF:

~~

To full-stroke exercise these valves requires injecting, SIRW tank

~

water into the Primary Coolant System (PCS). TMs.:test path is not available during normal operations since the PCS is at a greater pressure than the HPSl/RHPSI pump discharge. Alsoithe injection of the highly borated SIRW tank water into the Primary Coolant System (PCS) would result in a reactivity change power reduction and possibly a pressure/temperature transient. Testing at any plant condition greater than Cold Shutdown (Reactor Vessel head' *removed or equivalent) will result in thermal shock to the injection nozzles.

Full-stroke testing is not possible during cold shutdown periods due to Technical Specifications 3.3 pump operability limitations below 260°F (Low Temperature Overpressurization - 10CFR 50 Appendix G).

To full-stroke exercise this valve to the close position requires quanti~atively verifying flow in the reverse direction-when the valve is seated. This test is not possible during any mode of operation siriceno. direct or indirect method of quantitative reverse flow ve~~f-i_cat ion exists.

  • Proc No EM-09-02 Revision 14 Page 17 of 57 ALTERNATIVE TESTING:

RELIEF REQUEST BASIS NUMBER 8 (Continued)

These valves shall be tested as follows:

1.

During normal plant operations, part stroke testing shall be performed on a quarterly basis per Inservice Test Procedure Q0-19, "HPSI Pumps".

2.

During refueling outages with the vessel head removed, full-stroke testing per Inservice Test Procedure R0-65, "HPSI/RHPSI Check Valve Test" shall be performed.

Additionally, these check valves shall be disassembled and inspected (including a manual full-stroke exercise) in accordance with Engineering Manual Procedure EM-28-02, "Preventative Maintenance Program for Check Valves" in lieu of closure testing. This method is in compliance with Generic Letter 89-04.

1 QUALIFICATION PROGRAM:

None INSTRUMENTATION DESCRIPTION:

The instruments used are identified in the test document.

Each instrument used.to verify adherence to acceptance criteria is maintained in accordance with Palisades Administrative Procedures.

Each instrument is further identified on the Equipment Data Base as "Q" or "B" in the "X" field of the Q-List Interpretation.

BASELINE DATA:

These HPSI check valves were tested as follows:

1.

Init:Jal testing was performed per Preoperational Test Procedure Numt>e*r 12. Test valves were 1000 psig at greater than 250 gpm.

  • .1:**.. :
  • if
2.

At.i*~**ch refueling outage with the vessel h_ead removed, l!Jservice Te.st Procedure R0-65, "HPSI/RHPSI Check Valve Test" reconfims the initial test valves.

\\

3.

Additionally, these valves are part stroke tested each quarter by Inservice Test Procedure Q0-19, "HPSI Pumps".

The te$t values per this test are approximately 1270 psig at 175 gpm.

CK-3177, CK-3186 and CK-ES3411 are original plant equipment.

Valves have not been disassembled as part of the sample inspection program of EM-28-02 as of this revision to EM-09-02.

- ~ --*.

~

  • ~

I

~

I

'.u

~

~

RELIEF REQUEST BASIS NUMBER 8 (Continued)

Proc No EM-09-02 Revision 14 Page 18 of 57 ACCEPTANCE CRITERIA:

I.

2.
3.

Record of positive flow constitutes an acceptable part stroke test per Q0-19.

Recorded flow rates greater than 250 gpm constitute an acceptable full-stroke test per R0-65.

At each disassembly the valves are manually exercised to verify full-stroke capability. Also, the disassembled valve is inspected to ensure the internals are structurally sound (no loose or corroded parts.)

\\

\\

RELIEF REQUEST BASIS NUMBER 9 Proc No EM-09-02 Revision 14 Page 19 of 57 SYSTEM:

Engineering Safeguards (Containment Spray/M-204)

VALVES:

CK-3208, CK-ES3220, CK-3230 CATEGORY:

c CLASS: 2 FUNCTION:

1.

Prevent back flow of water through the Containment Spray Pumps.

2.

Pass flow from the Containment Spray pumps to Containment Spray Headers.

TEST REQUIREMENT:

I.

IWV-3521; Test Frequency - Exercise at 1 east once every three months.

2.

IWV-3522; Exercising Procedure - Exercise to the full open positio~~

BASIS FOR RELIEF:

To full-stroke exercise the Containment Spray Pump discharge check valves requires initiating the Containment Spray System and spraying down the containment. This test is not practical during ariy mode of operation.

ALTERNATIVE TESTING:

The Containment Spray Pump discharge check valves shall be tested as follows:

Each valve shall be part stroke tested once per quarter per lnservice Test Procedures Q0-10, "Containment Spray and LPSI Check Valve Test".

QUALIFICATION PROGRAM:

RELIEF REQUEST BASIS NUMBER 9 (Continued)

Proc No EM-09-02 Revision 14 Page 20 of 57 These check valves are disassembled and inspected (including a manual full-stroke exercise) in accordance with Engineering Manual Procedure EM-28-02, "Preventative Maintenance Program for Check Valves" in lieu of full flow testing. This method is in compliance with Generic Letter 89-04.

In addition, these valves are partial stroke exercised every three months in accordance with Procedure Q0-10 "Containment Spray and LPSI Check Valve Test.

INSTRUMENTATION DESCRIPTION:

The instruments used are identified in the test document.

Each instrument used to verify adherence to acceptance criteria is

~

maintained in accordance with Palisades Administrative Procedures.~

Each instrument is further identified on the Equipment Data Base ast "Q" or "B" in the "X" field of the Q-List Interpretation.

~

BASELINE DATA:

The Containment Spray Pump discharge check valves have been tested as follows:.

1.

Initial testing was completed per Preoperational Test Procedure Number 12. Test values ranged from 300 to 350 gpm at 260 psig. This testing was completed when the valves were in new condition.

2.

Subsequent testing has been performed per *Q0-10 and QP-16 at 300 gpm and 260 psig and lQOO gpm at 256 psig.

These testing actions are sufficient to monitor for valve degradjltion.

ACCEPTANCE CRITERIA:

Record of positive flow constitutes an acc_eptable part stroke test per Q0-10.

At each disas*sembly the valves are manually exerched to verify full-stroke capability. Also, the disassembled val~e is inspected to ensure the internals are structurally sound (no loose.or corroded parts).

RELIEF REQUEST BASIS NUMBER 10 Proc No EM-09-02 Revision 14 Page 21 of 57 SYSTEM:

Service Water CM-208-lAl VALVES:

CV-0884, CV-0885 CATEGORY:

B CLASS: 3 FUNCTION:

Provide service water to the Emergency Diesel Generator sets on demand.

TEST REQUIREMENT:

1.

IWV-3413; Power Operated Valves - Full-Stroke Time BASIS FOR RELIEF:

Technical Specifications require the EDGs to be functionally tested:

on a monthly basis. This entails starting, loadin9 and continued operation to verify operability of the EOG and it~support systems.

These valves are normally closed and fail open on a diesel start, they do not have position switches to locally or remotely exercise the valves. Degraded valve operability would be detected through the performance of the EOG Test, therefore relief is requested from the timing requirements of IWV-3413.

ALTERNATIVE TESTING:

Perform monthly EOG operability testing in accordance with Technical Specifications Test Procedure M0-7A-l and M0-7A-2.

QUALIFICATION PROGRAM:

None :

INSTRUMENTATJOll DESCRIPTION:

The instruments used are identified in the test document.

Each instrument used to verify adherence to acceptance criteria is maintained in accordance with Palisades Administrative Procedures.

Each instrument is further identified on the Equipment Data Base as "Q" or "B" in the "X" field of the Q-List Interpretation.

~.

RELIEF REQUEST BASIS NUMBER 10 (Continued)

Proc No EM-09-02 Revision 14 Page 22 of 57 BASELINE DATA:

Performance of M0-7A-l and M0-7A-2 in lieu of quarterly stroke time testing is an acceptable alternative for the following reasons:

1.

M0-7A-l and M0-7A-2 are performed three times per quarter as opposed to a quarterly procedure which would only be performed once.

2.

M0-7A-l and M0-7A-2 monitor jacket water pressure and temperature to determine acceptable subsystem performance.

3.

M0-7A-l and M0-7A-2 apply acceptable, alert and required action ranges to jacket water pressure and temperature. This action is a suitable alternative to stroke time measurements for monitoring valve degradation.

ACCEPTANCE CRITERIA:

Recorded jacket water pressures and temperatures in the acceptable~

range per M0-7A-l and M0-7A-2 constitutes. an acceptable test for the subject valves.

RELIEF REQUEST BASIS NUMBER 11 Proc No EM-09-02 Revision 14 Page 23 of 57 SYSTEM:

As Applicable VALVES:

AH Containment Penetration Valves CATEGORY:

FUNCTION:

A and AC CLASS: 1 and 2 These valves provide the primary containment barrie*r to minimize the consequences of an accident.

TEST REQUIREMENT:

1.

IWV-3427(b}; Corrective Action - For valves nominal pipe size 6 inches and larger, if a leakage rate exceeds the rate determined by the previous test by an amount that reduces the margin between

-~

measured leakage rate and the maximum permissible rate by 50% or 1

greater, the test frequency shall be doubled.

BASIS FOR RELIEF:

Data trending for local leakage rate testing provides no meaningful information that would justify the burden of taking corrective action.

With the increased frequency, operational constraints would be place upon the plant requiring extended shutdowns. Therefore, corrective action per IWV-3427(b} will not be used. This position is supported by Generic Letter 89-04.

The Appendix J, Type C testing is considered more limiting than the ASME Section XI Category A test requirements. Therefore, failure to meet the maximum allowable leakages rates as defined by the Palisades Nuclear Plant-Technical Specifications is more stringent *

. \\.

~: --

          • --- - ~ --. -

RELIEF REQUEST BASIS NUMBER 11 (Continued)

Proc No EM-09-02 Revision 14 Page 24 of 57 ALTERNATIVE TESTING:

1.

Seat leakage testing of Containment Isolation valves is performed per the requirements of 10 CFR 50 Appendix J, or as amended by the Palisades Plant Technical Specifications. Indivtdual leakage tests are performed in accordance with the appropriate Inservice Test Procedure (R0-32).

2.

Seat leakage test results of containment isolation valves are analyzed in accordance with 10 CFR 50 Appendix J, and*Technical Specifications.

3.

Containment isolation valve will be repaired or replaced as required when the leakage rate exceeds the maximum allowable as stated in the Palisades Nuclear Plant Technical Specifications or IWV~3427(a).

)i:

'>c QUALIFICATION PROGRAM:.

~

None a

~.

INSTRUMENTATION DESCRIPTION:

-~~ '-*.

The instruments used are identified in the, test do.cument. _Each instrument used to verify adherence to*acceptance*crtterh _is maintained fn* accordance with Palisades Administratt.ve Procedures.

Each instrument-is further identified on the Equipment Data. Base as "Q" or "B" in the "X" field of the Q-List Interpretation~

BASELINE DATA:

.. *1' Valve leakage rates. are recorded and trended *. Should a *leak rate approach the guideline leak rate of 13,040 cc/min, the.vaJ;ve is scheduled for maintenance according to the requirements of Technical Spec1fjcation*Surveillance Procedure R0-32, "LLRT-Local Leak Rate Te~t:~~.

Thesi.actions are sufficient for monitoring valve degradation.

2:10~*~~-.

'ACCEPTANCE. CRI-TERIA:

\\

The summat-ion of all LLRT results shall be less thta.n or equal to 56~000 cc/min (0.6L8 ). The calculated leak rate shall be less than the "Guideline Leak Rate" of 13,040 cc/min per penetr,ation which is an indication of the possibility of excessive leakage.

RELIEF REQUEST BASIS NUMBER 12 SYSTEM:

Component Cooling (M-209-3)

VALVES:

CV-0944, CV-0977B CATEGORY:

B CLASS: 3 FUNCTION:

Proc No EM-09-02 Revision 14 Page 25 of 57 Component Cooling isolation valves to and from the Rad Waste Evaps.

TEST REQUIREMENT:

1.

IWV-3411; Test Frequency - Exercise at least once every three months.

2.

IWV-3413; Power Operated Valves - Full-stroke time.

= *.

BASIS FOR RELIEF:

CV-0944 and CV-0977B are normally open valves which close on SIS.

There are no position switches to locally or remotely stroke the CV's.

The SIS test is manpower intensive and would be difficult to coordinate accurate stroke timing. Relief.ts requested fr~m the timing requirement of IWV-3414 or CV-0944 and CV-0977B.

ALTERNATIVE TESTING:

CV-0944 and CV-0977B shall be stroke tested during every cold shutdown, but not more frequently than once each quarter, through the performance of the Technical Specification Surveillance Procedure Q0-1, "Safety Inje~tion System", without stroke timing the valves.

QUALIFICATION PROGRAM:

None _

INSTRUMENTAT-ION DESCRIPTION:

Th~-instruments used are identified in the test document.

Each instrument used to verify adherence to ~cceptance criteria is maintained in accordance with Palisades Administrative Procedures.

Each instrument is further identified on the Equipment Data Base as "Q" or "B" in the "X" field of the Q-List Interpretation.

Proc No EM-09-02 Revision 14 Page 26 of 57 BASELINE DATA:

RELIEF REQUEST BASIS NUMBER 12 (Continued)

Testing per Q0-1 verifies the subject valves will travel to the close position. This is considered adequate for the following reasons:

1.

The valves are testing in the mode in which they would be called upon to mitigate an accident.

2.

Should one or both of these valves fail to close during an accident, an increase in flow demand of approximately 200 gpm (per FSAR Table 9.5) would be experienced.

This flow increase represents approximately 3 percent of one pumps flow capacity. Should this type of failure occur, there would remain approximately 1600 gpm of excess capacity available from the Component Cooling Pumps.

Based -0n statements 1 and 2 testing per Q0-1 is sufficient to assure the ability of these valves to close.

ACCEPTANCE CRITERIA:

Verification of closure during the performance of Q0-1 for valves CV-0944 and CV-09778 constitutes an acceptable test.

RELIEF REQUEST BASIS NUMBER 13 Proc No EM-09-02 Revision 14 Page 27 of 57 SYSTEM:

Comoonent Cooling System (M-209-2)

VALVES:- CK-CC401 and CK-CC402 CATEGORY:

FUNCTION:

c CLASS: 3 Component Cooling Water to east and west Engineering Safeguards check valves.

TEST REQUIREMENT:

I.

IWV-3521; Test Frequency - Exercise at least once every three months.

2.

IWV-3522; Exercising Procedure - Exercise to the full open position~

BASIS-FOR RELIEF:

To full-stroke exercise these valves requires quantitatively verifying each valve passes design accident flow.

This-test is not possible during any mode of operation since no direct or indirect method of quantitative fl ow veri fi cation exists.

ALTERNATIVE TESTING:

These check valves are disassembled and inspected (including a manual full-stroke exercise) in accordance with Engineering Manual Procedure EM-28-02, "Preventative Maintenance Program for Check Valves" in lieu of full flow testing. This method is in compliance with Generic Letter 89-04.

In addition, these check valves are partial stroke exercised every three !JIOnths.

QUALIFICATioff PROGRAM:

~-... ~~:.:_*.. -;,..

Nori;j;<-*

INSTRUMENTATION DESCRIPTION:

Th~ in~truments used are identified in the test doctiment.

Each instrument used to verify adherence to acceptance cri~eria is maintained in accordance with Palisades Administrative Procedures.

Each instrument is further identified on the Equipment Data Base as "Q" or "B" in the "X" field of the Q-List Interpretation *

" *,...... '.. ~ *~

BASELINE DATA:

RELIEF REQUEST BASIS NUMBER 13 !Continued)

~.'*

~k~ ;(..

Proc No EM-09-02 Revision 14

  • Page 28 of 57 Should there be a pipe break upstream of these check valves and subsequent failure of the same check valve, an excess flow of approximately 140 gallons (FSAR Table 9.5).

Even under the most limiting conditions an excess capacity of approximately 1500 gpm would be available from the Component Cooling Pumps. Therefore, these valves shall be classified as Category B and part stroke tested at least once per quarter.

ACCEPTANCE CRITERIA:

An acceptable test occurs when these valves meet the flow requirements of lnservice Test Procedures Q0-10, "Containment Spray and LPSI Check Valve Test", Q0-19, "HPSI Pumps" and Q0-20, "LPSI Pumps".

~

At each disassembly the valves are manually exercised to* verify full-stroke capability. Also, the disassembled valve is inspectedfto ensure the internals are structurally sound (no loase or corroded parts).

  • ~:

\\. \\*

\\ :*

~- *: -,

RELIEF REQUEST BASIS NUMBER 14 Proc No EM-09-02 Revision 14 Page 29 of 57 SYSTEM:

As Applicable VALVES:

All Fast-Acting valves with short stroke time less than or equal to 2 seconds.

CATEGORY:

A and B CLASS: I, 2 and 3 FUNCTION:

Various.

TEST REQUIREMENT:

I.

IWV-3417(a); Corrective Action - If the stroke time increases by 50%

or more from the previous test, then the test frequency shall be increased to once each month until corrective action is taken.

BASIS FOR RELIEF:

Fast acting valves have stroke times of such short-durations that comparison of measurements with previous data for specified percentage increases is not indicative of degrading valve performance.

With measurement of stroke times to the nearest second per IWV-3413(b), a very small increase in stroke time results in a large percentage of change.

Verification that these meet a specified maximum stroke time (2 seco~ds) of short duration, is adequate assurance of valve operability.

ALTERNATIVE TESTING:

The specified maximum limiting stroke time for all rapid acting valves is 2 seconds. Once the two second limit is exceeded, the valve shall be declafed inoperable and corrective action taken per IWV-34l7(b).

QUALIFICATIOll PRO&RAM:

~..

Norie.*

RELIEF REQUEST.BASIS NUMBER 14 (Continued)

INSTRUMENTATION DESCRIPTION:

Proc No EM-09-02 Revision 14 Page 30 of 57 The instruments used are identified in the test document.

Each instrument used to verify adherence to acceptance criteria is maintained in accordance with Palisades Administrative Procedures.

Each instrument is further identified on the Equipment Data Base as "Q" or "B" in the "X" field of the Q-List Interpretation.

BASELINE DATA:

None ACCEPTANCE CRITERIA:

Palisades shall apply a limiting stroke time of 2 seconds for these valves.

Once the two second limit is exceeded, the valve shall be~

declared inoperable and corrective action taken per the requirement~

of IWV-3417(b).

RELIEF REQUEST BASIS NUMBER 15 Proc No EM-09-02 Revision 14 Page 31 of 57 SYSTEM:

Primary Coolant System (M-201)

VALVES:

PRV-10428 and PRV-10438 CATEGORY:

FUNCTION:

8 CLASS: 1 The power operated relief valves (PORV's) provide primary system overpressure protection from (1) a charging/letdown imbalance, (2) the start of a high pressure safety injection (HPSI) pump and (3) initiation of forced circulation in the PCS when the steam generator temperature is higher than the PCS temperature.

Analysis shows that when three charging pumps are operating and letdown is isolated and a spurious HPSI occurs, the PORV setpoints,

ensure that 10 CFR 50, Appendix G pressure limits will nqt be exceeded.

Above 430°F, the pressurizer safety valves prevent

~

10 CFR 50, Appendix G limits from being exceeded by a charging/letdown imbalance.

The requirement that steam generator temperature be less than or equal to PCS temperature when forced circulation is initiated in the PCS ensures that an energy addition caused by heat transferred from the secondary system to the PCS will not occur. This requirement applies only to the initiation of forced circulation (the start of the first primary coolant pump) with one or more of the PCS cold leg temperatures less than 450°F.

Requiring the PORV~s to be operable when the shutdown cooling system is not isolated (M0-3015 and M0-3016 open) from the PCS ensures that the shutdown cooling system will not be pressurized above its design limits.

Proc No EM-09-02 Revision 14 Page 32 of 57 TEST REQUIREMENT:

RELIEF REQUEST BASIS NUMBER 15 {Continued}

IWV-1100 requires all class 1, 2 and 3 valves and their actuating and position indicating systems be tested in accordance with subsection IWV.

IWV-3413 requires a limiting value of stroke time of each valve be specified by the owner.

IWV-3417 requires an increased testing frequency and corrective action be taken if a measured stroke time exceeds I.SO times the previous measured value for valves with full-stroke times less than or equal to 10 seconds.

BASIS FOR RELIEF:

Performance of testing which includes the entire PORV actuating circuitry poses an undo hardship for the following reasons:

1.

This testing requires pressurization. with Nitrogen-between the block valves and the PORV.

Radiation exposure is estimated at 300 mR per test of the PORV and actuating circuits.

Therefore, relief from the requirement of IWV-1100 is requested.

When stroked at.zero differential pressure with the solenoid actuator, there are three primary forces which act on the PORV'.

The following force tends to open the valves:

1. Coil force.

The following force tends to close the PORV:

1. Spring force.

Friction force opposes motion in either direction.

RELIEF REQUEST BASIS NUMBER 15 (Continued)

Proc No EM-09-02 Revision 14 Page 33 of 57 Therefore, to have a healthy valve, the solenoid force must be greater than the friction force plus the spring force. This relationship is demonstrated when the valve successfully strokes from the closed to opened position. Because each of these forces is small in comparison to system pressure forces, the ability to stroke (without specification of a limiting value of stroke time) represents acceptable valve degradation and operation. Thus, relief from the requirements of IWV-3413 and IWV-3417 is requested.

ALTERNATIVE TESTING:

The PORV's shall be stroked using the solenoid actuator per Q0-06, "Cold Shutdown Test Procedure (includes Containment Isolation Valves)" at each cold shutdown but not necessarily more often than once per quarter. The ability to move from the full closed to the full open position (without the specification of a limiting value of stroke time) shall-constitute an acceptable test. Each PORV and its actuating circuit shall be exercised each refueling outage per

~

Surveillance Procedure RI-115, "Power Operated Relief V~lves"

~

Guidance of Generic Letter 89-04 position 6 shall be applied and a limiting value of two seconds shall be specified for RI-115-testing (see Relief Request 14).

QUALIFICATION PROGRAM:

MPR Associates, Incorporated analyzed the Target Rock Style 88RR valve for various conditions and concluded that total stroke open -

time at 330 psia/saturated water conditions will be 1.93 seconds (see MPR Study 1150, "Dynamic Analysis of Power Operated Relief Valves -

Palisades Nuclear Power Plant"). This analysis is the basis to show these valves are c~pable of fulfilling their safety function of opening in less than 2.1 seconds per the requirements of EA-FC-809-13, Rev. 1.

INSTRUMENTATION-DESCRIPTION:

The.lfJnstruments used are i dent ifi ed in the test document.

Each instrument used*to verify adherence to acceptance criteria-is maintained i:n accordance with Palisades Administrative Procedures.

Each instrument is further identified ori the Equipment Data Base as "Q" or "B"-irr the "X" field of the Q-List Interpretation.

\\

. ". :*' -:.. * :...... ~ \\.. "'~-*. ::. - -

Proc No EM-09-02 Revision 14 Page 34 of 57 BASELINE DATA:

RELIEF REQUEST BASIS NUMBER 15 (Continued)

Baseline data was obtained during preservice testing per Facility Change Package FC-809.

This data shows the PORV's will open in approximately 1.2 seconds with 200 psia of Nitrogen test system pressure. This value provides the baseline for monitoring, valve degradation at subsequent refueling outages per RI-115.

Baseline data also obtained during preservice testing, shows each valve is capable of stroking in approximately 1.4 seconds when manually stroked with the solenoid actuator.

Even though no limiting value of stroke time is specified for the PORV's when*testedin this mode, this data will be trended for predictive purposes\\

ACCEPTANCE CRITERIA:

Opening stroke times obtained per RI-115 which are less than or equ'll to two seconds shall constitute an acceptable refueling. outage testft

~

The ability to move to the open position per Q0-06.shallconstitute an acceptable cold shutdown test.

.\\ *\\.

"\\:

RELIEF REQUEST BASIS NUMBER 16 Proc No EM-09-02 Revision 14 Page 35 of 57 SYSTEM:

Engineering Safeguards CRHPSI/M-203-2)

VALVES:

CK-ES3408 and CK-ES3409 CATEGORY:

c CLASS: 1 FUNCTION:

1.

Provide HPSI to loop #1 Hot Leg injection Flow path.

2.

Prevent back flow of Primary Coolant System.

TEST REQUIREMENT:

1.

IWV-3521; Test Frequency - Exercise at least once every three months.

BASIS FOR RELIEF:

To full-stroke exercise these valves requires injecting SIRW tank

~,

water into the Primary Coolant System )PCS). This-test path cannot be used during normal power operations since the PCS is at a greater pressure than the HPSI pump discharge. Also the injection of the highly borated SIRW tank water into the Primary Coolant System {PCS) would result in a reactivity change power reduction and po~sibly a pressure/temperature transient. Testing at any plant condition greater than Cold Shutdown {rector vessel head removed or equivalent) would result in thermal shock to the injection nozzles.

Full-stroke testing is not possible during cold shutdown periods due to Technical Specifications 3.3 pump operability limitations below 260°F {Low Temperature Overpressurization - 10 CFR 50 Appendix G).

ALTERNATIVE TESTING:

These valves shall be tested as follows:

1.

Durtilg normal plant operations, partial stroke testing shall be -****

performed on a quarterly basis per Inserv~ce Testing Procedure Q0-19.

2.

During refueling outages with the vessel head removed, full-stroke testing per Inservice Testing Procedure R0-65 shall. be performed

  • Proc No EM-09-02 Revision 14 Page 36 of 57 RELIEF REQUEST BASIS NUMBER 16 (Continued)

QUALIFICATION PROGRAM:

None INSTRUMENTATION DESCRIPTION:

  • The instruments used are identified in the test document.

Each instrument used to verify adherence to acceptance criteria is maintained in accordance with Palisades Administrative Procedures.

Each instrument is further identified on the Equipment Data Base as "Q" or "B" in the "X" field of the Q-List Interpretation.-

BASELINE DATA:

ACCEPTANCE CRITERIA:

1.

Record of positive flow constitutes an acceptable part stroke test [

2.

per Q0-19.

Recorded flow rates greater than 250 gpm constituta an acceptable ful 1-stroke test per R0-65..

,~**

RELIEF REQUEST BASIS NUMBER 17 Pree No EM-09-02 Revision 14 Page 37 of 57 SYSTEM:

As applicable VALVES:

All applicable check valves CATEGORY:

c CLASS: 1, 2 and 3 FUNCTION:.

To provide a flow path and/or prevent back flow.

TEST REQUIREMENT:

1.

IWV-3521; Test Frequency - Exercise at least once every three months.

2.

IWV-3522; Exercising Procedure - Exercise to the full open position.

BASIS FOR RELIEF:

~~

This information is provided for disassembly and inspection of

~

category C check valves for which relief has been requested from ASME Section XI, IWV-3521 and 3522. Specific valve relief requests have been requested for the applicable valves as noted in the IST program document.

1.

Check Valve Exercising ASME Section XI provides an exercise procedure for Category C valves.

When direct or indirect methods of exercising check valves are not available or when it is impractical to exercise a valve using system flow, the check valve will be disassembled and inspected using a sampling technique~

For check valves which cannot be verified operable by standard ASME test procedures, Palisades Nuclear Plant will verify operability by di.sassembly and inspection.

2.

Tesi;;frequency

~\\::.;,.!~~* ~'.

Check_valves will be disassembled and inspected in accordance with a sampling technique on a refueling outage basis on~,Y*

... :~

RELIEF REQUEST BASIS NUMBER 17 (Continued)

Proc No EM-09-02 Revision 14 Page 38 of 57

3.

Sampling Technique

4.
5.
6.

The sampling technique utilized at Palisades requires that one valve from each Group b~ disassembled and inspected each reactor refueling outage.

More than one valve from each grouping may be disassembled and inspected each refueling outage.

More than one valve from each grouping may be disassembled and inspected each refueling outage depending on outage duration.

A different valve in each Group will be disassembled and inspected at subsequent refueling outages.

All valves in each Group will be disassembled and inspected once before any one valve is disassembled and inspected twice.

The scheduling will continue for subsequent inspections.

Check Valve Groupi~gs Valve Groups are defined as each valve in a group having the following identical characteristics:

a

a. Unit
b. Manufacturer
c. Size
d.

Model number

e. Material of construction
f. Service conditions (i.e., process fluid, temperature, pressure, fl ow, etc.)

Disassembly/Inspection (Exercising)

Upon valve dtsassembly, a visual inspection of the valve internals is performed to ensure that all parts are intact and structurally sound (no loose or corroded parts).

. ~~

Dut:111g'. the visual inspection, the valve disk is manually exercised to ensure' the valve is capable of full-stroking.

-'l?:*

Corrective Act fons

/

/

If the disassembled valve's full-stroke capability'..is in question, the remaining valves in that group will be disassembled, inspected and full-stroke exercised during the same refueling autage.

If any valve fails to exhibit full-stroke capability, the valve shall be repaired or replaced in accordance with the corrective actions of IWV-3427(a).

RELIEF REQUEST BASIS NUMBER 18 Proc No EM-09-02 Revision 14 Page 39 of 57 SYSTEM:

Auxiliary Feedwater CM-207-21 VALVES:

CK-FW703, CK-FW704, CK-FW728 and CK-FW729 CATEGORY:

c CLASS: 2 FUNCTION:

Auxiliary Feedwater injection check valves

1.

Provide a flow path from auxiliary feedwater pumps to the steam generators.

2.

Prevent back flow.

TEST REQUIREMENT:

1.

IWV-3521; Test Frequency - Exercise at least once every three mont~~-

2.

IWV-3522; Exercising Procedure - Exercise to the f~ll open position.

BASIS FOR RELIEF:

To verify closing of the above check valves requires rever-se flow testing (with the other aux. feedwater pump) and quantifying the leakage past the valves. This test is impractical to perform and places constraints on normal plant operations due to the large volume of auxiliary feedwater that would be required to be drained between the check valve and upstream isolation valve prior to testing.

Additionally, by i.solating the upstream motor operated valve, the plant is placed in an LCO per Technical Specification 3.5.1.

ALTERNATIVE TESTING:

The~e check valves are verified closed during reactor refueling outages per Engineering Manual Procedure EM-28-02, "Preventative Maf.ntenance Program for Check Valves" which is a disassembly and __

inspection (including a manual full-strok~ exercise).

In addition leakage past the valves is* inonitored'(not quantified) by periodically-recording temperatures upstream of the check valves.

Elevated temperatures would indicate leakage past the valves.

.*.~

QUALIFICATION PROGRAM:

None RELIEF REQUEST BASIS NUMBER 18 (Continued)

INSTRUMENTATION DESCRIPTION:

Proc No EM-09-02 Revision 14 Page 40 of 57 The instruments used are identified in the test document.

Each instrument used to verify adherence to acceptance criteria is maintained in accordance with Palisades Admin.istrative Procedures.

Each instrument is further identified on the Equipment Data Base as "Q" or "B" in the "X" field of the Q-List Interpretation.

BASELINE DATA:

None ACCEPTANCE CRITERIA:

At each disassembly the auxiliary feedwater check valves are manualiy exercised to verify full-stroke capability. Also the disassembled valves are inspected to ensure the internals are structurally sound (no loose or corroded parts).

RELIEF REQUEST BASIS NUMBER 19 Pree No EM-09-02 Revision 14 Page 41 of 57 SYSTEM:

Service Water {M-208-lBl VALVES:

CK-SW407, CK-SW408, CK-SW409 and CK-SW410 CATEGORY:

FUNCTION:

c CLASS: 3 Containment air cooler outlet check valves - Provide a flow path for service water discharge from the air coolers.

TEST REQUIREMENT:

1.

IWV-3521; Test Frequency - Exercise at least once every three months.

2.

IWV-3522; Exercising Procedure - Exercise to the. full open position:.

BASIS.FOR RELIEF:

To verify full-stroke exercise capability requires-quantitatively verifying each of the above valves passes design accident flow rate.

This test is not possible to perform since no direct or indirect method of quantitative flow verification exists.

ALTERNATIVE TESTING:

These check valves are disassembled and inspected (including a manual full-stroke exercise) in accordance with Engineering Manual Procedure EM-28-02, "Preventative Maintenance Program for Check Valves", in lieu of full flow testing. This method is in compliance with Generic Letter 89-04.

In addition, these valves are partial stroke exercised every three months~

QUALIFICATION PROGRAM:

Norie*

Proc No EM-09-02 Revision 14 RELIEF REQUEST BASIS NUMBER 19 {Continued)

INSTRUMENTATION DESCRIPTION:

Page 42 of 57 The instruments used are identified in the test document.

Each instrument used to verify adherence to acceptance criteria is maintained in accordance with Palisades Administrative Procedures.

Each instrument is further identified on the Equipment Data Base as "Q" or "B" in the "X" field of the Q-List Interpretation.

BASELINE DATA:

None ACCEPTANCE CRITERIA:

At each disassembly the valves are manually exercised to verify full-stroke capability. Also, the disassembled valves are inspected to ensure the internals are structurally sound {no loose or corrode4 parts).

~

Proc No EM-09-02 Revision 14 Page 43 of 57 RELIEF REQUEST BASIS NUMBER 20 SYSTEM:

Chemical and Volume Control (M-202-IB}

VALVES:

CK-CVC2116 CATEGORY:

c CLASS: 2 FUNCTION:

Charging line to loop-2A check valve. Provide a flow path from the charging pump header to Primary Coolant System.

TEST REQUIREMENT:

1.

IWV-3521; Test Frequency - Exercise at least once every three months.

2.

IWV-3522;* Exercising Procedure - Exercis~ to the full open position~

BASIS FOR RELIEF:

To full-flow test CK-CVC2116 requires isolating the other charging line (loop - IA) and quantifying the flow past the valve.

To accomplish this test path requires isolating the manual valve (MV-2198) on the other charging line. This test is impractical to perform since a containment entry would be required into a high radiation area to isolate the valve.

This valve is full-stroke exercised during reactor refueling outages.

ALTERNATIVE TESTING:

Check valve CK-CVC2116 is disassembled and inspected (including a manual full-stroke exercise) in accordance with Engineering Manual Procedure EM-28-02, "Preventative Maintenance Program for Check Valves" in lieu of full flow testing. This method is in compliance with-Generic Letter 89-04.

QUALIFICATIOff,pRQGRAM:

None

"~. *. ~-~,- *..

  • RELIEF REQUEST BASIS NUMBER 20 (Continued)

Proc No EM-09-02 Revision 14 Page 44 of 57 INSTRUMENTATION DESCRIPTION:

The instruments used are identified in the test document.

Each instrument used to verify adherence to acceptance criteria is maintained in accordance with Palisades Administrative Procedures.

Each instrument is further *identified on the Equipment Data Base as "Q" or "B" in the "X" field of the Q-List Interpretation.

BASELINE DATA:

None ACCEPTANCE CRITERIA:

At each disassembly the valve is manually exercised to verify full-stroke capability. Also, the disassembled valve is inspe!=ted~o ensure the internals are structurally sound (no loose or corroded

~

parts).

J

,*.j

~..

RELIEF REQUEST BASIS NUMBER 21 Proc No EM-09-02 Revision 14 Page 45 of 57 SYSTEM:

Chemical and Volume Control (M-202-lBl VALVES:

CK-CVC2118 CATEGORY:

FUNCTION:

c CLASS: 2 Pressurizer auxiliary spray check valve. Provide a flow path from the charging line to the pressurizer.

TEST REQUIREMENT:

1.

IWV-3521; Test Frequency - Exercise at least once every three months.

2.

IWV-3522; Exercising* Procedure - Exercise to the full open pos~tio'\\.

BASIS.FOR RELIEF:

To verify full-stroke operability requires isolati~g the charging flow to loop IA and IB and quantifying the flow rate past the valve.

This test is impractical to perform since isolating the charging flow to the Primary Coolant System is not possible per Technical Specifications 3.2.2, and no other direct method of full-flow verification exists.

This valve is full-stroke exercised during reactor refueling outages.

ALTERNATIVE TESTING:

Check valve CK-CVC2116 is disassembled and inspected {including a manual full-stroke exercise} in accordance with Engineering Manual Proced~re EM-28-02, "Preventative Maintenance Program for Check Valves* in lieu of full flow testing. This method is in compliance with Generic Letter 89-04.

'."'::~.--.

QUALIFICATION~PROGRAM:

None

Proc No EM-09-02

: ":: -*,: ~

Revision 14 Page 46 of 57.

RELIEF REQUEST BASIS NUMBER 21 (Continued)

INSTRUMENTATION DESCRIPTION:

The instruments used are identified in the test document.

Each instrument used to verify adherence to acceptance criteria is maintained in accordance with Palisades Administrative Procedures.

Each instrument is further identified on the Equipment Data Base as "Q" or "B" in the "X" field of the Q-List Interpretation.

BASELINE DATA:

None ACCEPTANCE CRITERIA:

At each disassembly the valve is manually exercised to verify full-stroke capability. Also, the disassembled.. valve is. inspected;jto ensure the internals are structurally sound (no loose or corroded

~

parts).

+

'/";

RELIEF REQUEST BASIS NUMBER 22 Proc No EM-09-02 Revision 14 Page 47 of 57 SYSTEM:

Al 1 VALVES:

All CATEGORY:

As Applicable CLASS: All As Applicable FUNCTION:

TEST REQUIREMENT:

ASME Section XI (IWV-3417b and IWV 3523) states that when corrective action is required as a result of testing, the condition must be corrected within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> or the valve shall be declared inoperative.

In the event of testing during cold shutdown, condition shall be corrected prior to start-up.

BASIS FOR RELIEF:

The Palisades Nuclear Plant Technical Specification limiting

~

conditions for operations, and ASME Section XI, prGvide the controls by which valves and systems are declared. inoperative.

Palisades Technical Specifications also control entry into various operational conditions, which is generally more restrictive than the ASME Code,Section XI.

Failure to meet Section XI testing criteria should not, therefore, preclude plant start-up with that particular component inoperative, nor should the declaration of component or system inoperability be extended to 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

Plant safety is assured by adherence to Palisades Nuclear Plant Technical Specifications.

ALTERNATIVE TESTING:

The ability to declare component or system inoperability, and conduct plant start-up, shall be governed by Palisades Nuclear Plant Techni~al Specifications and not by ASME Section XI, IWV-3417b and IWV-3523.

Proc No EM-09-02 Revision 14 Page 48 of 57 RELIEF REQUEST BASIS NUMBER 23 SYSTEM:

All VALVES:

All CATEGORY:

As Applicable CLASS: All As Applicable FUNCTION:

TEST REQUIREMENT:

IWV-3411 "Test Frequency" states, "Category A and B valves shall be exercised at least once every 3 months, except as providing by IWV-3412(a), IWV-34 and IWV-3416."

IWV-3422 "Frequency" states, "test shall be conducted at least once every 2 years."

BASIS*FOR RELIEF:

Specification 4.0.2 establishes the conditions under which the specified time interval for Surveillance Requirements may* be extended.

Item a.-permits an allowable extension of the normal surveillance interval to facilitate surveillance schedulin~ and consideration of plant operating conditions that may not be suitable for conducting the surveillance; e.g., transient conditions or other ongoing surveillance or maintenance activities. Item b. limits the use of the provisions of item a. to ensure that it is not used repeatedly to extend the surveillance interval beyond that specified.

The limits of Specification 4.0.2 are based on engineering judgement and the recognition that the most probable result of any particular surveillance being; performed is the verification of conformance with Surveillance Requirements.

These provisions are sufficient to ensure that the reliability ensured through surveillance activities is not signifjcantly degraded beyond that obtained from the specified surveillance interval.

).

ALTERNATIVE TESTING:

RELIEF REQUEST BASIS NUMBER 23 (Continued)

Proc No EM-09-02 Revision 14 Page 49 of 57 Unless otherwise specified, each surveillance requirement shall be performed within the specified time interval with:

a.

A maximum allowable extension not to exceed 25% of the surveillance interval, and

b.

A total maximum allowable combined interval time for any three consecutive surveillance intervals not to exceed 3.25 times the specified surveillance interval.

QUALIFICATION PROGRAM:

None INSTRUMENTATION DESCRIPTION:

None BASELINE DATA:

None ACCEPTANCE CRITERIA:

None

I "

O' I

'4.1 I

RELIEF REQUEST BASIS NUMBER 24 Proc No EM-09-02 Revision 14 Page 50 of 57 SYSTEM:

Condensate Demineralizer System (M-220-ll VALVES:

CK-CD407 CATEGORY:

FUNCTION:

c CLASS: 2 Prevent inadvertent drainage of the Condensate Storage Tank T-2 in the event of an upstream line break of the non class piping.

TEST REQUIREMENT:

1.

IWV-3521; Test Frequency - Exercise at least once every three months.

2.

IWV-3522; Exercising Procedure - Exercise to the fully closed position.

BASIS FOR RELIEF:

To full-stroke exercise this valve to the close position requires quantitatively verifying flow in the reverse direction when the valve is seated~ This test is not possible during any mode of operation since no direct or indirect method of quantitative reverse flow verification exists.

~ ALTERNATIVE TESTING:

~

This check valve is disassembled and inspected (including a manual full stroke exerci~e) in accordance with Engineering Manual Procedure EM-28-02, "Preventative Maintenance Program for Check Valves" in lieu of full stroke testing. This method is in compliance with Generic Letter 89-04.

QUALIFICATION PROGRAM.:

Nol)~/

INSTRUMENTATION DESCRIPTION:

The instruments used are identified in the test do~ument. Each instrument used to verify adherence to acceptance criteria is maintained in accordance with Palisades Administrative Procedures.

Each instrument is further identified on the Equipment Data Base as "Q" or "B" in the "X" field of the Q-List Interpretation.

BASELINE DATA:

CK-CD407 was installed during the Palisades 90REFOUT via Facility Change Package FC-892-1.

l ACCEPTANCE CRITERIA:

RELIEF REQUEST BASIS NUMBER 24 (Continued)

Proc No EM-09-02 Revision 14 Page 51 of 57 At each disassembly the valves are manually exercised to verify full-stroke capability. Also, the disassembled valve is inspected to ensure the internals are structurally sound (no loose or corroded parts).

RELIEF REQUEST BASIS NUMBER 25 Proc No EM-09-02 Revision 14 Page 52 of 57 SYSTEM:

Auxiliary Feedwater System (M-207, Sheet 2)

VALVES:

CV-0727, CV-0736A, CV-0737A and CV-0749 CATEGORY:

FUNCTION:

B CLASS: 3 Auxiliary Feedwater flow control valves regulate flow to the plant steam generators and are classified as active valves.

TEST REQUIREMENT:

IWV-3400 Category A and B valves shall be exercised at least once every three months to the position required to fulfill their safety function, unless such operation is not practical during Plant operation.

Stroke times for each power operated valve will be specified in tha individual test procedure.

a Valves with remote position indicators shall be observed once every two years to verify valve operation is accurately indicated.

BASIS FOR RELIEF:

The subject valves are required to regulate feedwater flow to the steam generators. They are not required to go to the full open or closed position for Plant safety. Because of this, stroke time testing is not an appropriate indicator of valve performance.

ALTERNATIVE TESTING:

The fl ow regulating capability sha 11 be verified once per quarter per Palisades Technical Specification Surveillance Procedure Q0-21, "Aux11iary Feedwater System Valves, Inservice Test Procedure."

QUALIFICATION PROGRAM:

None INSTRUMENTATION DESCRIPTION:

The instruments used are identified in the test document.

Each instrument used to verify adherence to acceptance criteria is maintained in accordance with Palisades Administrative Procedures.

Each instrument is further identified on the Equipment Data Base as "Q" or "B" in the "X" field of the Q-List Interpretation.

BASELINE DATA:

RELIEF REQUEST BASIS NUMBER 25 (Continued)

Proc No EM-09-02 Revision 14 Page 53 of 57 The October 8, 1981, (Amendment 67) Technical Specification Table 4.1.3, Item 15 contained a monthly flow indication "Check" by "Comparison of Channels." While this testing requirement was deleted with the revision issued January 30, 1986, it is considered prudent to demonstrate flow channel operability on a quarterly basis and is maintained in Q0-21, "Auxiliary Feedwater System Valves, Inservice Test Procedure." This verification extends to Auxiliary Feedwater flow control valves.

ACCEPTANCE CRITERIA:

Original flow control setpoints for FIC-0727, FIC-0749, FIC-0736A and FIC-0737A were established at 150 gpm.

SC-87-156 increased the required "at flow" time for flow from the P-88 to 177 seconds.

To

~

compensate for this change the required flow was increased from 150~

to 155 gpm (each steam generator). During PRC review of.the SC and~

supporting changes in Q0-21, "Auxiliary Feedwater System Valves, Inservice Test Procedure," Revision 3 and R0-97 "Auxiliary Feedwater System Automatic Initiation Inservice Test Procedure," Revision 1, it was decided to add a 10 gpm increment to the setpoint-t~ allow for some setpoint error. This resulted in the established setpoint of 165 gpm for the P-8A/P-8B train.

To avoid confusion, the setpoint for the P-8C train was also increased to 165 gpm.

Therefore, the associated flow control circuitry including valves shall be capable of controlling flow to each steam generator at 165 gpm plus tolerance per Q0-21 "Auxiliary Feedwater System Valves, Inservice Test Procedure" acceptance criteria.

~

RELIEF REQUEST BASIS NUMBER 26 Proc No EM-09-02 Revision 14 Page 54 of 57 SYSTEM:

Chemical and Volume Control System CM-202-18)

VALVES:

CK-CVC2112 and CK-CVC2114 CATEGORY:

FUNCTION:

c CLASS: 1 Valves pass flow from the charging system to primary coolant loops IA and 2A.

Valves function to restrict backflow, but there is no*

leakage limit.

TEST REQUIREMENT:

1.

IWV-3521; Test Frequency - Exercise at least once every three h

~

2.

mont s.

~

~-=-

IWV-3522; Exercising Procedure - Exercise to the fully open and~

closed position.

~

~ BASIS FOR RELIEF:

~

~

I

~

~

To full-strcike ~xercise this valve to the close positto~fequires quantitatively verifying flow in the reverse dfrection*.wtien the valve is seated. This test is not possible during any mode of ciperation since no direct.or indirect method of quantitative reverse-flow verification exists.

ALTERNATIVE TESTING:

This check valve is disassembled and inspected (including a manual full-stroke exercise) in accordance with Engineering Manual Procedure EM-28-02, "Preventative Maintenance Program for Check Valves" in lieu of closure test1ng. This method is in compliance with Generic Letter 89-04 *

. ~/ \\,:

QUALIFICATIGNC-PROGRAM:

None**

INSTRUMENTATION "DESCRIPTION:

The instruments used are i dent i fi ed in the test docum.ent.

Each instrument used to verify adherence to acceptance criteria is maintained in accordance with Palisades Administrative Procedures.

Each instrument is further identified on the Equipment Data Base as "Q" or "B" in the "X" field of the Q-List Interpretation.

BASELINE DATA:

RELIEF REQUEST BASIS NUMBER 26 (Continued)

Proc No EM-09-02 Revision 14 Page 55 of 57 CK-CVC2112 and CK-CVC2114 are original plant equipment.

Neither valve has been disassembled as part of the sample inspection program as of this revision to EM-09-02.

ACCEPTANCE CRITERIA:

At each disasembly the valves are manually exercised to verify full-stroke capability. Also,. the disassembled valve is inspected to ensure the internals are structurally sound (no loose or corroded parts).

Additionally, each valve is tested to the open position on a quarterly basis via performance of Q0-17, "Inservice Test Procedure, Charging Pumps."

~

~ '

' \\.

d t Proc No EM-09-02 Revision 14 RELIEF REQUEST BASIS NUMBER 27 Page 56 of 57 SYSTEM:

Service Water System (M-213)

VALVES:

CK-SW401, CK-SW402, CK-SW403 CATEGORY:

c CLASS: 3 FUNCTION:

1.

Prevent back flow of service water through service water pumps.

2.

Provide a flow path from the service water pumps to the plant.

TEST REQUIREMENT:

1.

IWV-3521; Test Frequency - Exercise* at least once every three month~.

IWV-3522; Exercising Procedure - Exercise to the fully open and closed position.

~ BASIS FOR RELIEF:

~

~

Full flow exercising these check valves to the open position requires knowledge of the individual pump flow rates. Individual pump units do not have installed flow indicators and piping configuration will not allow an installation of_ indicators which meet Code.requirements.

To full-stroke exercise this valve to the close position requires quantitatively verifying flow in the reverse direction when the valve is seated. This test is not possible during any mode of operation since no direct or.indirect method of quantitat~ve reverse flow verification exists.

ALTERNATIVE TESTING:

Part~stroke quarterly per Inservice Test Procedures Q0-14, "Service Wat~r Pumps."

Theia-*eheck valves are disassembled and in.spected (including a manu.~l ful 1-stroke exercise) in accordance with.*fngineef".ing Manual Procedure EM-28-02, "Preventative Maintenance Program for Ch.eek Valves". This method is in compliance with Generic Letter 89-04. *,

QUALIFICATION PROGRAM:

None

RELIEF REQUEST BASIS NUMBER 27 (Continued)

INSTRUMENTATION DESCRIPTION:

Proc No EM-09-02 Revision 14 Page 57 of 57 The instruments used are identified in the test document.

Each instrument used to verify adherence to acceptance criteria is maintained in accordance with Palisades Administrative Procedures.

Each instrument is further identified on the Equipment Data Base as "Q" or "8" in the "X" field of the Q-List Interpretation.

BASELINE DATA:

CK-CVC2112 and CK-CVC2114 are original plant equipment.

Neither valve has been disassembled as part of the sample inspection program as of this revision to EM-09-02.

ACCEPTANCE CRITERIA:

j At each disasembly the valves are manually exercised to verify full-stroke capability. Also, the disassembled valve is inspectedtto ensure the internals are structurally sound {no loose or corroded~

parts).

Additionally, each valve is tested to the open position on a quarterly basis via performance of Q0-17, "Inservice Test Procedure, Charging Pumps."