ML18054B562
| ML18054B562 | |
| Person / Time | |
|---|---|
| Site: | Palisades |
| Issue date: | 04/17/1990 |
| From: | De Agazio A Office of Nuclear Reactor Regulation |
| To: | Berry K CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.) |
| Shared Package | |
| ML18054B563 | List: |
| References | |
| PAL-90-023, PAL-90-23, TAC-69344, NUDOCS 9004240151 | |
| Download: ML18054B562 (3) | |
Text
..
Docket No. 50-255 Serial No. PAL-90-023 Mr. Kenneth W. Berry Director, Nuclear Licensing Consumers Power Company 1945 West Parnall Road Jackson, Michigan 49201
Dear Mr. Berry:
April 17, 1990 ~
DISTRIBUTION DOCKET FILE NRC & LOCAL PDRs PD31 READING JZWOLINSKI PS HUTTLHJORTH OGC EJORDAN ACRS(lO)
CC HENG KWICHMAN EMURPHY
SUBJECT:
EDDY CURRENT METHODOLOGY - TEST QUALIFICATION PROGRAM (TAC 69344)
On April 13, 1989, a meeting was held at aackson, Michigan between the staff and Consumers Power Company (CPCo) to discuss the status of the MIZ-18 eddy current system qualification program.
The meeting was attended also by Mr. C.
Dodd of Oak Ridge National Laboratory.
Mr. Dodd is a consultant to the staff on eddy current test technology.
Mr. Dodd's report of this meeting is enclosed.
At the time the meeting was held, the CPCo program was not yet completed; however, based upon the April 13, 1989, discussions the staff and Mr. Dodd concluded that the CPCo qualification program was addressing the appropriate issues satisfactorily.
By letter dated August 30, 1989, CPCo documented completion of the MIZ-18 qualification program and provided a description of the results.
In view of our findings from the April 13, 1989, meeting and the successful application of MIZ-18 during the fall 1989 steam generator inspections, we do not plan any further review of the August 30, 1989, submittal. Therefore, all review actions under TAC 69344 are completed.
Enclosure:
Meeting Summary cc w/enclosure:
See next page PM/PD31:~*
ADEAGAZIO 04f;J'/90 Sincerely, Albert W. De Agazio, Sr.Project Manager Project Directorate III-1 Division of Reactor Projects - III, IV, V & Special Projects Office of Nuclear Reactor Regulation Q~<t; (A)DD~D31:DRSP DDIIANNI 04//) /90
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D. C. 20555 Docket No. 50-255 Serial No. PAL-90-023 Mr. Kenneth W. Berry Director, Nuclear Licensing Consumers Power Company 1945 West Parnall Road Jackson, Michigan 49201
Dear Mr. Berry:
April 17, 1990
SUBJECT:
EDDY CURRENT METHODOLOGY - TEST QUJl.LIFICATION PROGRAM (TAC 69344)
On April 13, 1989, a meeting was held at Jackson, Michigan between the staff and Consumers Power Company (CPCo) to discuss the status of the MIZ-18 eddy current systerr qualification program.
The meeting was attended also by Mr. C.
Dadd of Oak Ridge National Laborator~.
~r. Dodd is a consultant tc tht staff on eddy c.urn;r1t test te.chnology.
Mr. Dodd's report of this meetir:£ is enclosed.
At the time the meeting was held, the CPCo program was net yet completed; howevEr~ based upon the April 13, 1989, discussions the staff and Mr. Dcdd concluded that the CPCo qualification program was addressing th~ appropriate issuH satisfactorily.
By letter dated August 30, 1989, CPCo documented completion of the MIZ-18 qualification program and provided a descriptior1 of the results. In view of our findings from th~ April 13, 1989, meeting and the successful applicatio~ of MIZ-18 during the fall 1989 steam generator inspections, we do not plan any further review of the August 30, 1989, submittal. Therefore, all review actions under TAC 69344 are completed.
Enclosure:
Meeting Summary cc w/enclosure:
See next page Sincerely,
~~~nager Project Directorate III-1 Division of Reactor Projects - III, IV, V & Special Projects Office of Nuclear Reactor Regulation
\\.
Mr. Kenneth W. Berry Consumers Power Company cc:
M. I. Miller, Esquire Sidley & Austin 54th Floor One First National Plaza Chicago, Illinois 60603 Mr. Thomas A. McNish, Secretary Consumers Power Company 212 West Michigan Avenue Jackson, Michigan 49201 Judd L. Bacon, Esquire Consumers Power Company 212 West Michigan Avenue Jackson, Michigan 49201 Regional Administrator, Region III U.S. Nuclear Regulatory Contnissfon 799 Roosevelt Road Glen Ellyn, Illinois 60137 Jerry Sarno Townsh;'p Supervisor Covert Township 36197 M-140 Highway Covert, Michigan 49043 Office of the Governor Room 1 - Capitol Building Lansing, Michigan 48913 Mr. Gerald B. Slade Plant General Manager Pa 1i sades Pl ant 27780 Blue Star Memorial Hwy.
Covert, Michigan 49043 Resident Inspector c/o U.S. Nuclear Regulatory Conmission Pali sades Pl ant 27782 Blue Star Memorial Hwy.
Covert, Michigan 49043 Palisades Plant Nuclear Facilities and Envirorvnental Monitoring Section Office Division of Radiological Health
- P.O. Box 30035 Lansing, Michigan 48909