  • . t consumers Power POW ERIN&

MICHlliAN'S PRO&RESS General Offices: 1945 West Parnall Road, Jackson, Ml 49201 * (517) 788-0453 July 31, 1989 Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 DOCKET 50-255 - LICENSE DPR PALISADES PLANT -

OCTOBER 1989 OUTAGE EDDY CURRENT INSPECTION PLANS AND MIZ-18 QUALIFICATION STATUS (TAC NO 69344)

, David P Hoffman Vice President Nuclear Operations By letter dated May 11, 1989, Consumers Power Company committed to provide the NRC with steam generator eddy current inspection plans for the upcoming October 1989 outage by July 31, 1989.

Also, by letter dated February 24, 1989, Consumers committed to complete qualification of the MIZ-18 eddy current inspection program by July 31, 1989.

The status of each of these commitments follows.

October 1989 Outage Eddy Current Inspection Scope Consumers Power Company contracted MPR Associates to perform a steam generator tube flaw size/vibration analysis to assess the ability for continued operation of the Palisades steam generators for the current operating cycle..

This analysis concluded continued operation does not present a significant risk.

The results of this report were submitted for NRC review by our letter dated May 22, 1989.

In addition, MPR was also contracted to provide longer term recommendations for ope~ation, assuming the current steam generators would not be replaced before 1993.

MPR has completed their recommendations.

The basis for these recommendations is a support plate stress evaluation to identify tubes within the Palisades steam generators that may be susceptible to circumferential stress corrosion cracking.

The evaluation considered stress and deflection analyses of tube support plates, the location of tube support plate flow circulation boles and recent Palisades history with respect to tube leaks and tube cracking.

The analysis indicates that the recent B steam generator tube cracking at support plate 13 is in a region of very high plate stress.

Consequently, tli~se -~ub_e:~_a_!:~_ con_~~~e~ed __ ~o-be particularly susceptible to stress corrosion 8908090105 890731 PDR ADOCK 05000255 Q

PDC

-OC0789-001 l-NL02 A CMS' ENERGY COMPANY

)

'Nuclear Regulatory Commission Palisades Plant 1989 Outage Eddy Current Inspection Plans July 31, 1989 cracking.

On the other hand, the most recent B steam generator leaking tube at support plate 3 is not in a region of high plate stress or high relative plate deflection.

Other regions of this plate are at significantly higher stress and other tubes supported at this plate are calculated to be at higher relative stress and deflections.

Consequently the stress and deflection analysis of the tube support plates does not indicate the leaking tube in support plate 3 is more susceptible to cracking than many of the other tubes in this plate.

MPR identified 1006 tubes to be tested in A steam generator with the 4C4F 2

probe at all tube support elevations.

Of these, 239 tubes were also identified for inspection using the MRPC probe.

The tubes were further prioritized to permit selection of those most susceptible to the hypothetical failure mechanism.

In B steam generator 783 tubes were identified for inspection with the 4C4F probe at all tube support elevations and, of these, 94 tubes were identified for inspection with the MRPC probe.

The MRPC probe inspections were recommended only at support plates 13 and 3, near the regions of recent tube leaks.

All of the tube sampling is recommended on the hot leg side of the steam generators and most of these inspections are limited to Quadrant 2 because all the recent leakers have been in this quadrant.

contains a tubesheet map for each steam generator showing the tubes recommended for inspection. contains the corresponding tube inspection listing for each steam generator.

Subsequent to the MPR initiation of their analysis and development of their long term recommendations, Consumers Power Company has initiated planning for replacement of both Palisades steam generators.

We are currently developing a plan for a fall 1990 steam generator replacement.

Requests for proposal have been generated and contractor bids are being prepared.

Shipment of the new steam generators is scheduled for completion this fall.

The decision process is planned for completion by early September 1989.

Because of the uncertainty of the engineering effort required, licensing review cycle and material availability, the replacement decision has a potential for being delayed one operating cycle.

If the decision to replace steam generators is delayed, Consumers Power Company is planning to inspect all of the tubes recommended in the MPR stress evaluation.

The 4C4F (or equivalent probe to be determined by the MIZ-18 qualification project) and the MRPC probes will be used as MPR has recommended.

If the decision is to replace steam generators in the fall of 1990, steam generator tube inspections may be reduced in scope.

The reduced scope inspection plan has not been finalized.

MPR Associates has been consulted for their input on a potentially reduced scope inspection.

Consumers Power Company will inform the NRC of the final inspection scope prior to the start of the outage.

OC0789-0011-NL02

-'\\

..Nuclear Regulatory Commission Falisades Plant 1989 Outage Eddy Current Inspection Plans July 31, 1989 MIZ-18 Qualification Project Status 3

Consumers Power Company has collected and analyzed wastage, IGA, and circum-ferential slit data for the 540 bobbin, 580 bobbin, 4C4F, 8Xl, MRPC and the axial wound rotation~l techniques.

A total of 311 defects were evaluated with each of these probes.

Data collection for a given device involved testing each defect with four different probes.

Each probe was run through a given standard four times and four different interpreters analyzed the data collected.

Defects ranged from 0% to 100% throughwall and contained dents between 0 and 30 mils radial.

Once the data analysis phase was completed, the ECT data was merged with the actual defect depth and dent information for each flaw.

Metallurgical exam-ination of the IGA defects resulted in depth morphology measurements which reflected average IGA depth, maximum average IGA depth, maximum IGA penetration, average stringer depth and maximum average stringer depth.

Statistical analysis of the data base is currently in progress.

The original objectives are as follows:

A.

Determine the detection limits and detection accuracy of each probe in relation to IGA, wastage ~md circumferential slits with and without the influence of radial dents.

B.

Determine the ability to size defects for each probe in relation to IGA, wastage and circumferential slits with and without the influence of radial dents.

Special consideration will be given to the IGA defects in order to determine what defect morphology each probe is responding to, ie., average IGA depth, maximum average IGA depth, maximum IGA penetration, average stringer depth or maximum average stringer depth.

The sizability accuracy over ranges of defect depths will be determined.

C.

Qualify the motorized axial wound rotational probe for sleeve examina-tions.

Determine the detection and sizing accuracy of the axial rotational probe on sleeve defect standards.

With respect to a steam generator replacement decision, the original objectives are prioritized as follows:

A.

Verify the flaw characterization capabilities of the probes currently being used by Consumers Power Company (ie., bobbin and 4C4F), in conjunction with the MIZ-18 tester, are equivalent or superior to the capabilities of the MIZ-12 tester.

B.

Determine if the bobbin probe provides improved flaw characterization capabilities over the 4C4F probe in areas of IGA.

C.

Determine if the 8Xl probe provides improved flaw characterization capabilities over the 4C4F probe.

OC0789-0011-NL02

\\

'*Nuclear Regulatory Commission Palisades Plant 1989 Outage Eddy Current Inspection Plans July 31, 1989 D.

Complete the sleeve qualification using the axial wound rotational probe.

E.

Perform remainder of statistical analysis per the original objectives.

Consumers Power Company originally committed to submit the results of the qualification to the NRC by July 31, 1989.

We will be unable to meet this 4

date due to th~ tremendous quantity of data that must be statistically evaluated and documented.

This delay has been compounded by delays in earlier phases of the qualification (ie., data collection and analysis) which required additional time due to the large amount of data.

In order to implement the 4C4F inspection technique with the MIZ-18 tester in the October 1989 outage, item A above must be completed.

Consumers Power Company will therefore, as a minimum, submit the results of the item A evaluations to the NRC by August 31, 1989.

Any part of the qualification that is not completed prior to the October 1989 outage will be r~assessed given Consumers Power Company's steam generator replacement decision.

We will info~m the NRC of the status on the qualification in our August 31, 1989 submittal.

David P Hoffman Vice President Nuclear Operations CC Administrator, Region III, USNRC NRC Resident Inspector - Palisades Plant Attachments OC0789-0011-NL02

OC0789-0011-NL02 ATTACHMENT 1 Consumers Power Company Palisades Plant Docket 50-255 A AND B STEAM GENERATOR TUBESHEET INSPECTION MAPS July 31, 1989 2 Pages

.. "6 L.nc*

~':!il!!l~l'P

=~~::.,,,

~ s s i

~ * : ; s s 1 s i '~ill I.

  • .. >~

Ri::d ssr:s :t!, l'J,111;..

11 i1:!llO~:i:l,~Si'1',Ff;*I::;

Shaded areas represent tubes recommended for inspection in B Steam Generator hot leg per MFR analysis

~}

U1 ::

u

~

llS IH lz.J '"

~ JJO 111,,.

II "!

llJ ui

~~:,

IC1 JOI.

~:: IM

"" =

.. n*..

OC0789-0011-NL02 ATTACHMENT 2 Consumers Power Company Palisades Plant Docket 50-255 A AND B STEAM GENERATOR TUBE INSPECTION LISTINGS July 31, 1989 42 Pages

TABLE A-1 PALISADES STEAM GENERATOR A INSPECTION TABLE PLATE QUAD LINE ROW ELEVATION 2

84 13 9

2 84 15 2,9 2

83 12 9

2 83 14 9

2 83 16 2,9 2

83 18 2,4,9 2

83 24 2,4,9 2

82 13 9

2 82 15 2,9 2

82 17 2,9 2

82 19 2,4,9 2

82 21 2,4,9 2

82 23 2,4,9 2

82 25 2,4,9,10 2

82 27 2,4, 10 2

82 29 2,4,10 2

82 31 2,4,10 2

81 12 9

2 81 14 9

2 81 16 2,9 2

81 18 2,4,9 2

81 20 2,4,9 2

81 22 2,4,9 2

81 24 2,4,9,10 2

81 26 2,4,9,10 2

81 28 2,4,10 2

81 30 2,4,10 2

81 32 2,4,10 2

81 34 2,4,10 2

81 36 10 2

81 38 10 2

80 17 9

2 80 19 2,4,9 2

80 21 2,4,9 2

80 23 2,4,9 2

80 25 2,4,9,10 2

80 27 2,4,10 A.1-1

t.

TABLE A-1 (Cont'd)

PALISADES STEAM GENERATOR A INSPECTION TABLE PLATE QUAD LINE ROW ELEVATION 2

80 29 2,4,10 2

80 31 2,4,10 2

80 33 2,4,10 2

80 35 2,4,10 2

80 37 10 2

80 39 10 2

80 41 10 2

80 43 2

79 26 2,4,9 2

79 28 2,4 2

79 30 2,4 2

79 32 2,4 2

79 34 2,4 2

79 36 2

79 38 2

79 40 2

79 42 2

79 44 2

79 46 11 2

79 48 11 2

78 33 2,4 2

78 35 2,4 2

78 37 2

78 39 2

78 41 2

78 43 2

78 45 2

78 47 11 2

78 49 11 2

78 51 11 2

78-53 4, 11 2

77 40 2

7.7 42 2

77 44 2

77 46 2

77 48 11 2

77 50 11 2

. 77 52 4, 11 2

77 54 4, 11 2

77 56 4, 11 2

76 45 2

76.

47 2

76 49 11 2

76:

51 11 A.1-2

(

TABLE A-1 (Cont'd)

PALISADES STEAM GENERATOR A INSPECTION TABLE PLATE QUAD LINE ROW ELEVATION 2

76 53 4, 11 2

76 55 4, 11 2

76 57 4, 11 2

76 59 4, 11 2

75 18 4

2 75 50 11 2

75 52 4, 11 2

75 54 4, 11 2

75 56 4,11 2

75 58 4, 11 2

75 60

.4, 11 2

74 55 4, 11 2

74 57 4,11 2

74 59 4, 11 4

2 74 61 4, 11 2

74 65 4, 11 2

74 67 4, 11 2

73 18 4

2 73 58 11 2

73 60 4, 11 2

73 64 4,11 2

73 66 4, 11 2

73 68 3,4,11 2

72 59 11 2

72 61 4, 11 2

72 63 4, 11 2

72 65 4, 11 2

72 67 4, 11 2

72 69 3,4,11 2

72 71 3, 11 2

72 73 3, 11 2

71 14 4

2 71 16 4

2 71 18 4

2 71 60 11 2

71 64 4, 11 2

71 66 4, 11 2

71 68 3,4,11 2

71 70 3,4,11 2

71 72 3, 11 2

71 74 3, 11 2

70 59 11 2

70 61 11 2

70 63 11 A.1-3

QUAD 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 LINE 70 70 70 70 70 70 70 69 69 69 69 69 69 69 69 69 69 69 68 68 68 68 68 68 68 67 67 67 67 67 67 67 66 66 66 66 66 66 66 65 65 65 65 65 TABLE A-1 (Cont'd)

PALISADES STEAM GENERATOR A INSPECTION TABLE PLATE ROW ELEVATION 65 11 67 11 69 3,4,11 71 3, 11 73 3, 11 75 3, 11 77 3, 11 18 4

60 11 64 11 66

.11 68 11 70 3, 11 72 3' 11 74 3, 11 76 3, 11 78 3, 11 80 3, 11 59 11 61 11 75 3, 11 77 3, 11 79 3, 11 81 3, 11 83 3, 11 18 4

60 11 76 3, 11 78 3, 11 80 3, 11 82 3, 11 84 3, 11 59 11 61 11 79 3, 11 81 3, 11 83 3, 11 85 3, 11 87 12 60 11 82.

3, 11 84 3, 11 86 12 88 12 A.1-4

(

TABLE A-1 (Cont'd}

PALISADES STEAM GENERATOR A INSPECTION TABLE PLATE QUAD LINE ROW ELEVATION 2

64 59 11 2

64 61 11 2

64 85 11 2

64 87 12 2

64 89 12 2

64 91 2,12 2

63 60 11 2

63 86 12 2

63 88 12 2

63 90 2,12 2

. 63 92

.2, 12 2

62 61 11 2

62 89 12 2

62 93 2,12 2

62 95 2' 12 2

61 60 11 2

61 90 12 2

61 92 2,12 2

61 94 2,10,12 2

61 96 2,10,12 2

60 61 11 2

60 93 2,12 2

60 95 2,10,12 2

60 97 2,10,12 2

60 99 2,10,12 2

59 96 2,10,12 2

59 98 2,10,12 2

59 100 2,10,12 2

58 61 11 2

58 95 10 2

58 97 2,10,12 2

58 99 2,10,12 2

58 101 2,10,12 2

57 94 10 2

57 96 10 2

57 98 2,10,12 2

57 100 2,10,12 2

57 102 2,3,10 2

57 104 2,3,10 2

56 59 11 2

56 61 11 2

56 95 10 2

56 97 10 2

56 99 10 A.1-5

TABLE A-1 (Cont'd)

PALISADES STEAM GENERATOR A INSPECTION TABLE PLATE QUAD LINE ROW ELEVATION 2

56 101 2,10 2

56 105 2,3,10 2

55 60 11 2

55 94 10 2

55 96 10 2

55 98 10 2

55 100 10 2

55 102 2,10 2

55 104 2,3,10 2

55 106 2,3, 10 2

54 59

.11 2

54 61 11 2

54 103 2

2 54 105 2,3,10 2

54 107 3,10,12 2

53 60 11 2

53 106 3,10,12 2

53 108 3,10,12 2

52 59 11 2

52 61 11 2

52 107 3,10,12 2

52 109 3,10,12 2

51 52 3

2 51 54 3

2 51 56 3

2 51 58 3.

2 51 60 3, 11 2

51 62 3

2 51 64 3

2 51 66 3

2 51 108 3,12 2

51 110 3,10,12 2

51 112 3,10,12 2

50 59 11 2

50 61 11 2

50 85 11 2

50 109 3,12 2

50 111 3,10,12 2

50 113

.. 3,10,12 2

49 60 11 2

49 108 12 2

49 110 3,12 2

49 112 3,10,12 2

49 114 3,4,10,11,12 A.1-6

~

TABLE A-1 (Cont'd)

PALISADES STEAM GENERATOR A INSPECTION TABLE PLATE QUAD LINE ROW ELEVATION 2

40 85 11 2

40 115 11 2

40 117 11 2

40 119 11, 13 2

40 121 4,11,13 2

40 123 4,11,13 2

39 18 4

2 39 70 4

2 39 108 12 2

39 114 4

2 39 118

.13 2

39 120 13 2

39 122 4,11,13 2

39 124 4,11,13 2

38 85 11 2

38 119 13 2

38 121 13 2

38 123 4,11,13 2

38 125 4' 11, 13 2

37 14 4

2 37 16 4

2 37 18 4

2 37 70 4

2 37 72 4

2 37 74 4

2 37 110 4

2 37 112 4

2 37 114 4

2 37 118 13 2

37 120 13 2

37 122 13 2

37 124 11, 13 2

37 126 11, 13 2

36 59 11 2

36 85 11 2

36 119 13 2

36 121 13 2

36 123 13 2

36 125 11, 13 2

  • 36 127 11, 13 2

35 18 4

2 35 60 11 2

35 70 4

2 35 108 12 A.1-8

TABLE A-1 (Cont'd)

PALISADES STEAM GENERATOR A INSPECTION TABLE PLATE QUAD LINE ROW ELEVATION 2

35 114 4

2 35 118 13 2

35 120 13-2 35 122 13 2

35 124 13

- 2 35 126 11, 13 2

35 128 11, 13 2

34 61 11 2

34 85 11 2

34 119 13 2

34 121

.13 2

34 123 13 2

34 125 13 2

34 127 11, 13 2

34 129 11,13,14 2

33 18 4

2 33 60 11 2

33 70 4

2 33 86 11, 12 2

33 108 12 2

33 114 4

2 33 118 13 2

33 120 13 2

33 122 13 2

33 124 13 2

33 126 13 2

33 128 11,13 2

33 130 11, 13 2

32 59 11 2

32 61 11 2

32 119 13 2

32 121 13 2

32 123 13 2

32 125 13 2

32 127 13 2

32 129 11,13,14 2

31 60 11 2

31 86 11, 12 2

31 108 12 2

31 118 13 2

31 120.

13 2

31 122 13 2

31 124_

13 2

31 126 13 A.1-9

TABLE A-1 (Cont'd)

PALISADES STEAM GENERATOR A INSPECTION TABLE PLATE QUAD LINE ROW ELEVATION 2

31 128 13 2

31 130 13 2

30 59 11 2

30 61 11 2

30 119 13 2

30 121 13 2

30 123 13 2

30 125 13 2

30 127 13 2

30 129 13,14 2

30 131

.13 2

29 60 11 2

29 86 11, 12 2

29 108 12 4

2 29 118 13 2

29 120 13 2

29 124 13 2

29 126 13 2

29 128 13 2

29 130 13 2

29 132 13 2

28 59 11 2

28 61 11 2

28 85 11, 12 2

28 131 13,14 2

28 133 2,11,13,14 2

27 86 11, 12 2

27 108 12 2

27 132 13, 14 2

27 134 13,14 2

26 25 9,10 2

26 61 11 2

26 85 11, 12 2

26 131 13,14 2

26 133 13,14 2

25 60 11 2

25 86 11, 12 2

25 108 12 2

25 132 13,14.

2 24 25 9, 10 2

24 61 11 2

24 119 12 2

23 86 11, 12 2

23 108 12 A.1-10

TABLE A-1 (Cont'd)

PALISADES STEAM GENERATOR A INSPECTION TABLE PLATE QUAD LINE ROW ELEVATION 2

22 25 9,10 2

22 59 11 2

22 85 11, 12 2

22 119 12 2

22 133 2,4,11,13,14 2

21 20 3

2 21 22 3

2 21 24 3

2 21 26 3

2 21 28 3

2 21 30 3

2 21 32 3

2 21 34 3

2 21 36 3

2 21 38 3

2 21 108 12 2

20 25 9,10 2

20 59 11 2

20 61 11 2

20 119 12 2

19 60 11 2

19 86 11, 12 2

19 108 12 2

18 25 9, 10 2

18 59 11 2

18 61 11 2

18 85 11, 12 2

18 115 3

2 18 119 12 2

17 60 11 2

17 108 12 2

17 114 3

2 17 116 3

2 17 138 2, 11, 13 2

16 59 11 2

16 61 11 2

16 115 3

2 16 119 12 2

16 135 2,4,11,13 2

16 137 2,4,11,13 2

15 60 11 2

15 68 3,4 2

15 70 3,4 2

15 114 3,11,12 A.1-11

t TABLE A-1 (Cont'd)

PALISADES STEAM GENERATOR A INSPECTION TABLE PLATE QUAD LINE ROW ELEVATION 2

15 118 3,11,12 2

15 120 3,11,12 2

15 122 3,11,12 2

15 124 3,11,12 2

15 126 3,11,12 2

15 128 3,11,12 2

15 130 3,11,12,13 2

15 132 3,11,12,13 2

15 134 3,11,12,13 2

15 136 2,3,4,11,12,13 2

15 138

.2' 3 '4' 11, 12' 13 2

14 47 10, 11 2

14 59 11 2

14 69 3,4 2

14 85 11, 12 2

14 115 3,11,12 2

14 117 3,11,12 2

14 119 3,11,12 2

14 121 3,11,12 2

14 123 3,11,12 2

14 125 3,11,12 2

14 127 3,11,12 2

14 129 3,11,12 2

14 131 3,11,12,13 2

14 133 3,11,12,13 2

14 135 2,3,4,11,12,13 2

14 137 2,3,4,ll,12,13 2

13 60 11 2

13 68 3,4 2

13 70 3,4 2

13 86 11, 12 2

13 114 3,4,11,12 2

13 116 3,4,11,12 2

13 118 3,4,11,12 2

13 120 3,11,12 2

13 122 3,11,12 2

13 124 3,11,12 2

13 126 3,11,12 2

13 128 3,11,12,13 2

13 130 3,11,12,13 2

13 132 3,11,12,13 2

13.

134 3,11,12,13 2

13 136 2,3,4,11,12,13 2

12.

47 9, 10 A.1-12

TABLE A-1 (Cont'd)

PALISADES STEAM GENERATOR A INSPECTION TABLE PLATE QUAD LINE ROW ELEVATION 2

12 59 11 2

12 61 11 2

12 69 3,4 2

12 85 11, 12 2

12 115 3,4,11,12 2

12 117 2,3,4,11,12 2

12 119 3,12 2

12 121 3

2 12 123 3

2 12 125 3

2 12 127 3

2 12 129

  • 3, 13 2

12 131 3

2 12 133 3

2 12 135 3

2 12 137 3,12 2

12 139 3,12 2

11 60 11 2

11 68 3,4 2

11 70 3,4 2

11 86 11, 12 2

11 114 3,4,11,12 2

11 116 3,4,11,12 2

11 118 3,4,11,12 2

11 120 12 2

11 136 12 2

11 138 12 2

10 47 9, 10 2

10 59 11 2

10 61 11 2

10 69 3,4 2

10 115 3,4,11,12 2

10 119 11, 12 2

10 129 13 2

10 137 12 2

10 139 12 2

9 60 11 2

9 68 3,4 2

9 70 3,4 2

.9 86 11, 12 2

9 108 12 2

9 114 3,4,11,12 2

9 116 3,4,11,12 2

9 118 3,4,11,12 A.1-13

TABLE A-1 (Cont'd)

PALISADES STEAM GENERATOR A INSPECTION TABLE QUAD LINE ROW PLATE ELEVATION 2

9 120 12 2

9 138 12 2

8 47 10, 11 2

8 59 11 2

8 61 11 2

8 69 3,4 2

8 115 3,4,11,12 2

8 117 2,3,4,11,12 2

8 119 12 2

8 129 13 2

8 137 12 2

7 60 11 2

7 68 3,4 2

7 70 3,4 2

7 86 11, 12 2

7 108 12 2

7 114 3,4,11,12 2

7 116 3,4,11,12 2

7 118 3,4,11,12 2

7 120 12 2

7 138 12 2

6 47 10, 11 2

6 59 11 2

6 61 11 2

6 69 3,4 2

6 115 3,4,11,12 2

6 119 12 2

6 129 13 2

6 137 3,12,14 2

6 139 3,12,14 2

5 60 11 2

5 68 3,4 2

5 70 3,4 2

5 108 12 2

5 120 12 2

5 138 3,12,14 2

5 140 3,12,14 2

4 47 10, 11 2

4 59 11 2

4 61 11 2

4 69.

3,4 2

4 85 11, 12 2

4 115 3,4,11,12 2

4 117 2,3,4,11,12 A.1-14

TABLE A-1 (Cont'd)

PALISADES STEAM GENERATCJR A INSPECTION TABLE PLATE QUAD LINE ROW ELEVATION 2

4 119 12 2

4 129 13 2

4 137 3,12,14 2

4 139 3,12,14 2

3 60 11 2

3 68 3,4 2

3 70 3,4 2

3 86 11, 12 2

3 114 3,4,11,12 2

3 116 3,4,11,12 2

3 118 3,4,11,12 2

3 138 3,14 2

2 47 10, 11 2

2 59 11 2

2 61 11 2

2 69 3,4 2

2 85 11, 12 2

2 115 3,4,11,12 2

2 119 12 2

2 129 13 2

2 137 3,14 2

2 139 3,14 3

1 60 11 3

1 68 3,4 3

1 70 3,4 3

1 118 3,4,11,12 3

1 120 12 3

1 138 3, 14 3

1 140 3,14 3

2 137 3,14 3

2 139 3, 14 3

3 138 3, 14 3

3 140 3,14 3

4 137 3,12,14 3

4 139 3,12,14 3

5 138 3,12,14 3

5 140 3,12,14 3

-6 137 3,12,14 3

7 138 12 3

7 140 12 3

8 137 12 3

9 138 12 3

9 140 12 3

10 137 12 A.1-15

TABLE A-1 (Cont'd)

PALISADES STEAM GENERATOR A INSPECTION TABLE PLATE QUAD LINE ROW ELEVATION 3

11 136 12 3

11 138 12 3

12 117 3

3 12 119 3

3 12 121 3

3 12 123 3

3

.12 125 3

3 12 127 3

3 12 129 3

3 12 133 3

3 12 135 3

3 12 137 3,12 3

12 139 3,12 3

13 116 3

3 13 120 3

3 13 122 3

3 13 124 3

3 13 126 3

3 13 128 3

3 13 130 3

3 13 132 3

3 13 134 3

3 13 136 2,3,4,11,12 3

14 117 3

3 14 119 3

3 14 121 3

3 14 123 3

3 14 125 3

3 14 127 3

3 14 129 3

3 14 131 3

3 14 133 3

3 14 135 2,3,4,11,12,13 3

14 137 2,3,4,11,12,13 3

15 116 3

3 15 118 3

3 15 122 3

3 15 124 3

3 15 126 3

3 15 128 3

3 15 130 3

3 15 132 3

3 15 134 3

3 15 136 2,3,4,11,13 A.1-16

TABLE A-I (Cont'd)

PALISADES STEAM GENERATOR A INSPECTION TABLE PLATE QUAD LINE ROW ELEVATION 3

15 138 2,3,4,11,l3 3

16 135 2,4,11,13 3

16 137 2,4,11,13 3

17 136 2,4,11,13 3

17 138 2,4,11,13 3

18 135 2,4,11,13,14 3

18 137 2,4,11,13,14 3

19 134 2,4,11,13,14 3

19 136 2,4,11,13,14 3

20 137 2,4,11,13,14 3

21 134 2,4,11,13,14 3

21 136 2,4,11,13,14 3

22 133 2,4,11,13,14 3

22 135 2,4,11,13,14 3

23 134 2,4,11,13,14 3

23 136 2,4,11,13,14 3

24 133 4,11,13,14 3

24 135 4,11,13,14 3

25 132 13,14 3

25 134 13,14 3

26 131 14 3

26 133 14 3

27 132 14 3

27 134 14 3

28 131 14 3

28 133 14 3

29 118 13 3

29 120 13 3

29 122 13 3

29 124 13 3

29 126 13 3

29 128 13 3

29 130 13 3

30 119 13 3

30 121 13 3

30*

123 13 3

30 125 13 3

30 127 13 3

30

.129 13 3

30 131 13 3

31 118 13 3

31.

120 13 3

31 122 13 3

31 124 13 A.1-17

~

TABLE A-1 (Cont'd)

PALISADES STEAM GENERATOR A INSPECTION TABLE PLATE QUAD LINE ROW ELEVATION 3

31 126 13 3

31 128 13 3

31 130 13 3

32 119 13 3

32 121 13 3

32 123 13 3*

32 125 13 3

32 127 13 3

32 129 11,13 3

33 118 13 3

33 120 13 3

33 122 13 3

33 124 13 3

33 126 13 3

33 128 11, 13 3

33 130 11, 13 3

34 119 13 3

34 121 13 3

34 123 13 3

34 125 13 3

34 127 11,13 3

34 129 11, 13 3

35 118 13 3

35 120 13 3

35 122 13 3

35 124 13 3

35 126 11, 13 3

35 128 11, 13 3

36 119 13 3

36 121 13 3

36 123 13 3

36 125 11, 13 3

36 127 11, 13 3

37 118 13 3

37 120 13 3

37 122 13 3

37 124 11, 13 3

37 126 11, 13 3

38 119 13 3

  • 39 121 13 3

38 123 4,11,13 3

38 125 4,11,13 3

39 118 13 3

39 120 13 A.1-18

TABLE A-1 (Cont'd)

PALISADES STEAM GENERATOR A INSPECTION TABLE PLATE QUAD LINE ROW ELEVATION 3

39 122 4,11,13 3

39 124 4,11,13 3

40 119 13 3

40 121 4,11,13 3

40 123 4,11,13 3

41 118 13 3

41 120 4,11,13 3

41 122 4,11,13 3

42 119 4' 11, 13 3

42 121 4,11,13 3

43 118 4,12,13 3

43 120 4, 11, 13 3

44 117 4,12 3

44 119 4,12,13 3

45 116 4,12 3

46 115 4,12 3

47 114 4,12 3

47 116 4,12 3

48 111 3

3 48 113 3,12 3

48 115 3,4,12 3

49 110 3,12 3

49 112 3,10,12 3

49 114 3,4,10,12 3

50 109 3,12 3

50 Ill 3,10,12 3

50 113 3,10,12 3

51 108 3,12 3

51 110 3,10,12 3

51 112 3,10,12 3

52 107 3,10,12 3

52 109 3,10,12 3

53 106 3,10,12 3

53 108 3,10,12 3

54 103 2

3 54 105 2,3,10 3

54 107 3,10,12 3

55 102 2

3 55 104 2,3,10.

3 55 106 2,3,10 3

56 101.

2 3

56 103 2,3,10 3

56 105 2,3,10 3

57 98 2,12 A.1-19

TABLE A-1 (Cont'd)

PALISADES STEAM GENERATOR A INSPECTION TABLE PLATE QUAD LINE ROW ELEVATION 3

57 100 2,12 3

57 102 2,3,10 3

57 104 2,3,10 3

58 97 2,12 3

58 99 2,10,12 3

58 101 2,10,12 3

59 94 2,12 3

59 96 2,12 3

59 98 2,12 3

59 100 2,12 3

60 93 2,12 3

60 95 2,12 3

60 97 2,12 3

60 99 2,12 4

3 61 90 12 3

61 92 2' 12 3

61 94

. 2, 12 3

61 96 2,12 3

62 89 12 3

62 91 2,12 3

62 93 2,12 3

62 95 2,12 3

63 86 12 3

63 88 12 3

63 90 2,12 3

63 92 2,12 3

64 85 11 3

64 87 12 3

64 89 12 3

64 91 2,12 3

65 82 3, 11 3

65 84 3, 11 3

65 86 12 3

65 88 12 3

66 79 3, 11 3

66 81 3, 11 3

66 83 3, 11 3

66 85 3, 11 3

66 87 12 3

67 76 3, 11 3

67 78 3, 11 3

67 80 3, 11 3

67 82 3,11 3

67 84 3,11 A.1-20

TABLE A-1 (Cont'd)

PALISADES STEAM GENERATOR A INSPECTION TABLE PLATE QUAD LINE ROW ELEVATION 3

68 75 3, 11 3

68 77 3, 11 3

68 79 3, 11 3

68 81 3, 11 3

68 83 3, 11 3

69 70 3, 11 3

69 72 3, 11 3

69 74 3, 11 3

69 76 3, 11 3

69 78 3, 11 3

69 80 3, 11 3

70 69 3,4,11 3

70 71 3, 11 3

70 73 3, 11 4

3 70 75 3, 11 3

70 77 3, 11 3

71 64 4, 11 3

71 66 4, 11 3

71 68 3,4,11 3

71 70 3,4,11 3

71 72 3, 11 3

71 74 3, 11 3.

72 61 4

3 72 63 4, 11 3

72 65 4, 11 3

72 67 4, 11 3

72 69 3,4,11 3

72 71 3, 11 3

72 73 3, 11 3

73 58 11 3

73 60 4, 11 3

73 62 4, 11 3

73 64 4, 11 3

73 66 4, 11 3

73 68 3,4, 11 3

74 55 4, 11 3

74 57 4, 11 3

74 59 4,11 3

74 61 4, 11 3

74 63 4, 11 3

74 65 4, 11 3

74 67 4, 11 3

75 50 11 3

75 52 4, 11 A.1-21

TABLE A-1 (Cont'd)

PALISADES STEAM GENERATOR A INSPECTION TABLE PLATE QUAD LINE ROW ELEVATION 3

75 54 4, 11 3

75 56 4, 11 3

75 58 4, 11 3

75 60 4, 11 3

75 62 4, 11 3

76 45 3

76 47 3

76 49 11 3

76 51 11 3

76 53 4, 11 3

76 55 4, 11 3

75 57 4, 11 3

76 59 4, 11 3*

77 40 3

77 42 3

77 44 3

77 46 3

77 48 11 3

77 50 11 3

77 52 4, 11 3

77 54 4, 11 3

77 56 4, 11 3

78 33 2,4 3

78 35 2,4 3

78 37 3

78 39 3

78 41 3

78 43 3

78 45 3

78 47 11 3

78 51 11 3

78 53 4, 11 3

79 26 2,4,9 3

79 28 2,4 3

79 30 2,4 3

79 32 2,4 3

79 34 2,4 3

79 36 3

79 38 3

79 40 3

79 42 3

79*

44 3

79 46 11 3

79*

48 11 A.1-22

TABLE A-1 (Cont'd)

PALISADES STEAM GENERATOR A INSPECTION TABLE PLATE QUAD LINE ROW ELEVATION 3

80 17 9

3 80 19 2,4,9 3

80 21 2,4,9 3

80 23 2,4,9 3

80 25 2,4,9,10 3

80 27 2,4,10 3

80 29 2,4,10 3

80 31 2,4,10 3

80 33 2,4,10 3

80 35 2,4,10 3

80 37 10 3

80 39 10 3

80 41 10 3

80 43 3

81 12 9

3 81 14 9

3 81 16 2,9 3

81 18 2,4,9 3

81 20 2,4,9 3

81 22 2,4,9 3

81 24 2,4,9,10 3

81 26 2,4,9,10 3

81 28 2,4,10 3

81 30 2,4,10 3

81 32 2,4,10 3

81 34 2,4,10 3

81 36 10 3

81 38 10 3

82 13 9

3 82 15 2,9 3

82 17 2,9 3

82 19 2,4,9 3

82 21 2,4,9 3

82 25 2,4,9,10 3

82 27 2,4,10 3

82 31 2,4,10 3

83 12 9

3 83 14 9

3 83 16 2,9 3

  • 83 18 2,4,9 A.1-23

QUAD 3

3 3

3 3

LINE 83 83 83 84

. 84 TABLE A-1 (Cont'd)

PALISADES STEAM GENERATOR A INSPECTION TABLE ROW 20 22 24 13 15 A.1-24 PLATE ELEVATION 2,4,9 2,4,9 2,4,9 9

2,9

TABLE A-2 PALISADES STEAM GENERATOR B INSPECTION TABLE PLATE QUAD LINE ROW ELEVATION 2

84 13 9

2 84 15 2,9 2

83 12 9

2 83 14 9

2 83 16 2,9 2

83 18 2,4,9 2

83 20 2,4,9 2

83 22 2,4,9 2

83 24 2,4,9 2

82 13 9

2 82 15 2,9 2

82 17 2,9 2

82 19 2,4,9 2

82 21 2,4,9 2

82 23 2,4,9 2

82 25 2,4,9,10 2

82 27 2,4,10 2

82 29 2,4,10 2

82 31 2,4,10 2

81 12 9

2 81 14 9

2 81 16 2,9 2

81 18 2,4,9 2

81 20 2,4,9 2

81 22 2,4,9 2

81 24 2,4,9,10 2

81 26 2,4,9,10 2

81 28 2,4,10 2

81 30 2,4,10 2

81 32 2,4,10 2

81 34 2,4,10 2

81 36 10 2

81 38 10 2

80 17 9

2 80 19 2,4,9 2

80 21 2,4,9 2

80 23 2,4,9 A.2-1

QUAD 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

LINE 80 80 80 80 80 80 80 80 80 80 79 79 79 79 79 79 79 79 79 79 79 78 78 78 78 78 78 78 78 78 78 78 77 77 77 77 77 77 77 77 77 76 76 76 76 TABLE A-2 (Cont'd)

PALISADES STEAM GENERATOR B INSPECTION TABLE PLATE ROW ELEVATION 25 2,4,9,10 27 2,4,10 29 2,4,10 31 2,4,10 33 2,4,10 35 2,4,10 37 10 39 10 41 10 43 26 2,4,9 28 2,4 30 2,4 32 2,4 34 2,4 36 38 40 42 46 11 48 11 33 2,4 35 2,4 37 39 41 43 45 47 11 49 11 51 11 53 4, 11 40 42 44 46 48 11 50 11 52 4, 11 54

. 4, 11 56 4, 11 45 47 49 11 51 11 A.2-2

TABLE A-2 (Cont'd)

PALISADES STEAM GENERATOR B INSPECTION TABLE PLATE QUAD LINE ROW ELEVATION 2

76 53 4, 11 2

76 55 4, 11 2

76 57 4, 11 2

76 59 4, 11 2

75 18 4

2 75 50 4, 11 2

75 52 4, 11 2

75 54 4,11 2

75 56 4, 11 2

75 58 4, 11 2

75 60 4,11 2

74 55 4, 11 2

74 57 4,11 2

74 59 4,11

2.

74 61 4,11 2

74 63 4, 11 2

74 65 4,11 2

74 67 4, 11 2

73 18 4

2 73 58 11 2

73 60 4, 11 2

73 62 4, 11 2

73 64 4, 11 2

73 66 4,11 2

73 68 3,4, 11 2

72 59 11 2

72 61 4, 11 2

72 63 4,ll 2

72 65 4, 11 2

72 67 4,11 2

72 71 3,11 2

72 73 3, 11 2

71 14 4

2 71 16 4

2 71 18 4

2 71 60 11 2

71 64 4, 11 2

71 66 4, 11 2

71 72 3, 11 2

71 74 3, 11 2

70 59 11 2

70 61 11 2

70.

63 11 2

70 65 11 2

70 67 11 A.2-3

TABLE A-2 (Cont'd)

PALISADES STEAM GENERATOR B INSPECTION TABLE PLATE QUAD LINE ROW ELEVATION 2

70 69 3,4, 11 2

70 71 3,11 2

70 73 3, 11 2

70 75 3, 11 2

70 77 3,11 2

69 18 4

2 69 60 11 2

69 64 11 2

69 66 11 2

69 68 11 2

69 70 3,11 2

69 72 3,11 2

69 74 3,11 2

69 76 3,11 2

69 78

. 3, 11 4

2 69 80 3,11 2

68 59 11 2

68 61 11 2

68 75 3, 11 2

68 77 3,11 2

68 79 3, 11 2

68 81 3,11 2

68 83 3, 11 2

67 18 4

2 67 60 11 2

67 76 3, 11 2

67 78 3, 11 2

67 80 3, 11 2

67 82 3, 11 2

67 84 3, 11 2

66 59 11 2

66 61 11 2

66 79 3, 11 2

66 81 3, 11 2

66 83 3, 11 2

66 85 3,11 2

65 60 11 2

65 82 3, 11 2

65 86 12 2

64 59 11 2

  • 64 61 11 2

64 85 11 2

63 60 11 2

63 86 12 2

63 90 2,12 A.2-4

-~------

TABLE A-2 (Cont'd)

PALISADES STEAM GENERATOR B INSPECTION TABLE PLATE QUAD LINE ROW ELEVATION 2

62 59 11 2

62 61 11 2

61 60 11 2

61 90 12 2

61 94 2,10,12 2

60 59 11 2

60 61 11 2

60 93 2, 12 2

60 95 2,10,12 2

60 99 2,10,12 2

59 60 11 2

59 94 2,10,12 2

59 96 2,10,12 2

59 100 2,10,12 2

58 59 11 2

58 61 11 2

58 95 10 2

58 101 2,10,12 2

57 60 11 2

57 94 10 2

57 96 10 2

57 98 2,10,12 2

57 100 2,10,12 2

57 102 2,3,10 2

57 104 2,3,10 2

56 59 11 2

56 61 11 2

56 95 10 2

56 97 10 2

56 99 10 2

56 105 2,3,10 2

55 60 11 2

55 94 10 2

55 96 10 2

55 98 10 2

55 100 10 2

55 102 2,10 2

55 104 2,3,10 2

55 106 2,3,10 2

54 59 11 2

54 105 2,3,10 2

54 101 3,10,12 2

53 60 11 2

53 108 3,10,12 2

52 59 11 A.2-5

TABLE A-2 (Cont'd)

PALISADES STEAM GENERATOR B INSPECTION TABLE PLATE QUAD LINE ROW ELEVATION 2

52 107 3,10,12 2

52 109 3,10,12 2

51 52 3

2 51 54 3

2 51 56 3

2 51 58 3

2 51 60 3, 11 2

51 66 3

2 51 108 3,12 2

51 112 3,10,12 2

50 59 11 2

50 85 11 2

50 109 3,12 2

50 111 3,10,12 2

50 113 3,10,12 2

49 108 12 2

49 112 3,10,12 2

49 114 3,4,10,11,12 2

48 59 11 2

48 113 3,12 2

. 48 115 3,4,11,12 2

47 108 12 2

47 114 4,11,12 2

47 116 4,11,12 2

46 61 11 2

46 115 4,11,12 2

46 117 4,11,12 2

45 60 11 2

45 108 12 2

45 114 11 2

45 116 4,11,12 2

44 47 10 2

44 61 11 2

44 85 11 2

44 115 11 2

43 60 11 2

43 108 12 2

43 114 11 2

43 116 11 2

42 59 11 2.

42 61 11 2

42 85 11 2

42 115 11 2

42 117 11 2

41 18 4

A.2-6

TABLE A-2 (Cont'd}

PALISADES STEAM GENERATOR B INSPECTION TABLE PLATE QUAD LINE ROW ELEVATION 2

41 60 11 2

41 70 4

2 41 108 12 2

41 114 4,11 2

41 116 11 2

40 59 11 2

40 61 11 2

40 115 11 2

40 117 11 2

39 18 4

2 39 60 11 2

39 70 4

2 39 108 12 2

39 114 4

2 38 59 11 2

38 61 11 2

37 14 4

2 37 16 4

2 37 18 4

2 37 60 11 2

37' 70 4

2 37 72 4

2 37 74 4

2 37 108 12 2

37 110

4.

2 37 112 4

2 37 114 4

2 36 59 11 2

36 61 11 2

36 85 11 2

35 18 4

2 35 60 11 2

35 70 4

2 35 108 12 2

35 114 4

2 34 59 11 2

34 61 11 2

34 85 11 2

33 18 4

2 33 60

. 11 2

33 70 4

2 33 86 11, 12 2

33 108

. 12 2

33 114 4

2 32 59 11 A.2-7

TABLE A-2 (Cont'd)

PALISADES STEAM GENERATOR B INSPECTION TABLE PLATE QUAD LINE ROW ELEVATION 2

32 61 11 2

32 85 11, 12 2

31 60 11 2

31 86 11, 12 2

31 108 12 2

30 59 11 2

30 61 11 2

30 85 11 2

29 60 11 2

29 86 11, 12 2

29 108 12 2

28 61 11 2

28 85 11, 12 2

27 60 11 2

27 86 11, 12 2

27 108 12 2

26 25 9,10 2

26 61 11 2

26 85 11, 12 2

25 60 11 2

25 86 11, 12 2

25 108 12 2

24 25 9, 10 2

24 61 11 2

24 85 11, 12 2

24 119 12,13 2

24 121 13 2

24 123 13 2

23 108 12 2

23 124 13 2

22 25 9,10 2

22 59 11 2

22 61 11 2

22 85 11, 12 2

22 119 12 2

22 125 13 2

21 20 3

2 21 22 3

2 21 24 3

2 21 26 3

2 21 30 3

2 21 32 3

2

21.

34 3

2 21 36 3

2 21 38 3

A.2-8

TABLE A-2 (Cont'd)

PALISADES STEAM GENERATOR B INSPECTION TABLE PLATE QUAD LINE ROW ELEVATION 2

21 60 11 2

21 86 11, 12 2

21 108 12 2

21 126 13 2

20 25 9,10 2

20 59 11 2

20 85 11, 12 2

20 119 12 2

20 127 13 2

19 60 11 2

19 86 11, 12 2

19 108 12 2

19 126 13 2

18 25 9, 10 2

18 59 11 4

2 18 61 11 2

18 85 11, 12 2

18 115 3

2 18 119 12 2

18 127 13 2

18 129 13 2

17 60 11 2

17 86 11, 12 2

17 108 12 2

17 116 3

2 17 130 13 2

16 47 10, 11 2

16 59 11 2

16 61 11 2

16 85 11, 12 2

16 115 3

2 15 60 11 2

15 68 3,4 2

15 70 3,4 2

15 86 3,4,11,12 2

15 108 12 2

15 114 3,11,12 2

15 116 3,11,12 2

15 120 3,11,12 2

15 122 3,11,12 2

  • 15 124 3,11,12 2

15 126 3,11,12 2

15 128 3,11,12 2

15 130 3,11,12,13 2

14 47 10, 11 A.2-9

.I

'. ~

TABLE A-2 (Cont'd)

PALISADES STEAM GENERATOR B INSPECTION TABLE PLATE QUAD LINE ROW ELEVATION 2

14 59 11 2

14 61 11 2

14 69 3,4 2

14 115 3,11,12 2

14 117 3,11,12 2

14 119

. 3,11,12 2

14 121 3,11,12 2

14 123 3,11,12 2

14 125 3,11,12 2

14 127 3,11,12 2

14 129 3,11,12 2

13 68 3,4 2

13 70 3,4 2

13 108 12 2

13 116 3,4,11,12 2

13 118 3,4,11,12 2

13 120 3,11,12 2

13 122 3,11,12 2

13 124 3,11,12 2

13 126 3,11,12 2

13 128 3,11,12 2

13 130 3,11,12,13 2

12 47 10, 11 2

12 59 11 2

12 61 11 2

12 69 3,4 2

12 85 11, 12 2

12 119 3,12 2

12 121 3

2 12 123 3

2 12 125 3

2 12 127 3

2 12 129 3,13 2

12 131 3

2 12 133 3

2 12 135 3

2 12 137 3,12 2

12 139 3,12 2

11 60 11 2

11 70 3,4 2

11 86 11, 12 2

11 114 3~4,11,12 2

11 116 3,4,11,12 2

11 118 3,4,11,12 2

11 1~6 12 A.2-10

TABLE A-2 (Cont'd)

PALISADES STEAM GENERATOR B INSPECTION TABLE PLATE QUAD LINE ROW ELEVATION 2

11 138 12 2

10 59 11 2

10 61 11 2

10 85 11, 12 2

10 115 3,4,11,12 2

10 117 2,3,4, 11, 12 2

10 119 11, 12 2

10 129 13 2

10 137 12 2

10 139 12 2

9 60 11 2

9 68 3,4 2

9 70 3,4 2

9 86 11, 12 2

9 108 12 4

2 9

114 3,4,11,12 2

9 118 3,4,11,12 2

9 120 12 2

9 138 12 2

9 140 12 2

8 47 10, 11 2

8 59 11 2

8 61 11 2

8 69 3,4 2

8 85 11, 12 2

8 115 3,4,11,12 2

8 117 2,3,4,11,12 2

8 119 12 2

8 129 13 2

8 137 12 2

8 139" 12 2

7 60 11 2

7 68 3,4 2

7 70 3,4 2

7 86 11, 12 2

7 114 3,4,11,12 2

7 116 3,4,11,12 2

7 118 3,4,11,12 2

7 120 12 2

7 138 12 2.

7 140 12 2

6 47 10, 11 2

6 59 11 2

6 69 3,4 2

6 85 11, 12 A.2-11

TABLE A-2 (Cont'd)

PALISADES STEAM GENERATOR B INSPECTION TABLE PLATE QUAD LINE ROW ELEVATION 2

6 ll5 3,4,11,12 2

6 119 12 2

6 129 13 2

6 137 3,12,14 2

6 139 3,12,14 2

5 60 11 2

5 68 3,4 2

5 70 3,4 2

5 86 11, 12 2

5 114 3,4,11,12 2

5 118 3,4,11,12 2

5 120 12 2

5 138 3,12,14 2

5 140 3,12,14 2

4 59 11 2

4 61 11 2

4 69 3,4 2

4 85 11, 12 2

4 117 2,3,4, 11, 12 2

4 119 12 2

4 129 13 2

4 137 3,12,14 2

4 139 3,12,14 2

3 60 11 2

3 68 3,4 2

3 114 3,4,11,12 2

3 120 12 2

3 138 3,14 2

2 47 10, 11 2

2 59 11 2

2 61 11 2

2 69 3,4 2

2 115 3,4,11,12 2

2 119 12 2

2 129 13 2

2 137 3, 14 2

2 139 3,14 3

1 60 11 3

1 68 3,4 3

1 70

' 3,4 3

1 114 3,4,11,12 3

1 120 12 3

1 138

. 3, 14 3

2 137 3, 14 3

  • 2 139 3, 14 A.2-12

~**

TABLE A-2 (Cont'd)

PALISADES STEAM GENERATOR B INSPECTION TABLE PLATE QUAD LINE ROW ELEVATION 3

3 138 3, 14 3

3 140 3' 14 3

4 137 3,12,14 3

4 139 3,12,14 3

5 138 3,12,14 3

5 140 3,12,14 3

6 137 3,12,14 3

6 139 3,12,14 3

7 138 12 3

7 140 12 3

8 137 12 3

8 139 3,12,14 3

9 138 12 3

9 140 12

3.

10 137 12 3

10 139 12 4

3 11 136 12 3

11 138 12 3

12 121 3

3 12 123 3

3 12 125 3

3 12 127 3

3 12 129 3

3 12 131 3

3 12 133 3

3 12 135 3

3 13 116 3

3 13 118 3

3 13 120 3

3 13 122 3

3 13 124 3

3 13 126 3

3 13 128 3

3 13 130 3

3 13 132 3

3 13 134 3

3 14 117 3

3 14 119 3

3 14 121 3

3 14 123 3

3 14 125 3

3 14 127 3

3

14.

129 3

3 14 131 3

3 14 133 3

A.2-13

~*,

TABLE A-2 (Cont'd)

PALISADES STEAM GENERATOR B INSPECTION TABLE PLATE QUAD LINE ROW ELEVATION 3

15 116 3

3 15 118 3

3 15 120 3

3 15 122 3

3 15 124 3

3 15 126 3

3 15 128 3

3 15 130 3

3 15 132 3

3 15 134 3

3 16 135 2,4,11,13 3

17 134 13 3

18 133 13 3

19 132 13 3

20 131 13 3

21 130 13 3

22 129 13 3

23 128 13 3

24 127 13 3

25 126 13 3

26 119 13 3

26 121 13 3

26 123 13 3

26 125 13 3

44 117 4,12 3

45 116 4,12 3

46 115 4,12 3

46 117 4,12 3

47 114 4,12 3

47 116 4,12 3

48 113 3,12 3

48 115 3,4,12 3

49 112 3,10,12 3

49 114 3,4,10,12 3

50 109 3,12 3

50 111 3,10,12 3

50 113 3,10,12 3

51 108 3,12 3

51 112 3,10,12 3

52 107 3,10,12 3

. 53 108 3,10,12 3

54 105 2,3,10 3

54 107 3,10,12 3

55 102 2

3 55 104 2,3,10 A.2-14

t

-~

~*

TABLE A-2 (Cont'd)

PALISADES STEAM GENERATOR B INSPECTION TABLE PLATE QUAD LINE ROW ELEVATION 3

55 106 2,3,10 3

56 101 2

3 56 103 2,3,10 3

56 105 2,3,10 3

57 100 2,12 3

57 102 2,3,10 3

57 104 2,3,10 3

58 97 2,12 3

58 99 2,10,12 3

58 101 2,10,12 3

59 94 2,12 3

59 96 2,12 3

59 98 2,12 3

59 100 2,12 3

60 95 2,12 3

61 90 12 4

3 61 92 2,12 3

61 94 2,12 3

62 89 12 3

62 91 2,12 3

63 86 12 3

63 88 12 3

65 82 3, 11 3

65 86 12 3

66 81 3, 11 3

66 83 3,11 3

66 85 3,11 3

67 76 3, 11 3

67 78 3, 11 3

67 80 3, 11 3

67 82 3,11 3

67 84 3, 11 3

68 75 3,11 3

68 77 3, 11 3

68 79 3, 11 3

68 81 3,11 3

68 83 3, 11 3

69 70 3, 11 3

69 72 3, 11 3

69 74 3,11 3

69 76 3, 11 3

69 78 3, 11 3

69 80 3~ 11 3

70 69 3,4,11 3

70 71 3,11 A.2-15

1

--1

7' I

TABLE A-2 (Cont'd)

PALISADES STEAM GENERATOR B INSPECTION TABLE PLATE QUAD LINE ROW ELEVATION 3

70 73 3, 11 3

70 75 3, 11 3

70 77 3, 11 3

71 64 4, 11 3

71 66 4,11 3

71 68 3,4,11 3

71 70 3,4, 11 3

71 72 3, 11 3

71 74 3, 11 3

72 61 4

3 72 63 4, 11 3

72 65 4, 11 3

72 67 4, 11 3

72 69 3,4,11 3

72 71 3, 11 4

3 72 73 3, 11 3

73 58 11 3

73 60 4,11 3

73 62 4, 11 3

73 64 4, 11 3

73 66 4, 11 3

73 68 3,4,11 3

74 55 4, 11 3

74 57 4, 11 3

74 59 4, 11 3

74 61 4, 11 3

74 65 4, 11 3

74 67 4, 11 3

75 50 11 3

75 52 4, 11 3

75 54 4, 11 3

75 56 4, 11 3

75 58 4, 11 3

76 45 3

76 47 3

76 49 11 3

76 51 11 3

76 53 4, 11 3

76 55 4, 11 3

76 57 4, 11 3*

76 59 4,11 3

77 46 3

77 48.

11 3

77 50 11 3

77 52 4, 11 A.2-16

1

~

,J TABLE A-2 (Cont'd)

PALISADES STEAM GENERATOR B INSPECTION TABLE PLATE QUAD LINE ROW ELEVATION 3

77 54 4, 11 3

77 56 4, 11 3

78 33 2,4 3

78 35 2,4 3

78 37 3

78 39 3

78 41 3

78 43 3

78 45 3

78 47 11 3

78 49 11 3

78 51 11 3

78 53 4, 11 3

79 26 2,4,9 3

79 28 2,4 3

79 30 2,4 3

79 32 2,4 3

79 34 2,4 3

79 36 3

79 38 3

79 40 3

79 42 3

79 46 11 3

79 48 11 3

80 17 9

3 80 19 2,4,9 3

80 21 2,4,9 3

80 23 2,4,9 3

80 25 2,4,9,10 3

80 27 2,4,10 3

80 29 2,4,10 3

80 31 2,4,10 3

80 33 2,4,10 3

80 35 2,4,10 3

80 37 10 3

80 39 10 3

80 41 10 3

80 43 3

81 12 9

3 81 14

,9 3

81 16 2,9 3

81 18 2,4,9 3

81 20

. 2,4,9 3

81 22 2,4,9 3

81 24 2,4,9,10 A.2-17

J

  • ~~

'f

-= : -ll

'I.

~

  • )
  • TABLE A-2 (Cont'd)

PALISADES STEAM GENERATOR B INSPECTION TABLE PLATE QUAD LINE ROW ELEVATION 3

81 26 2,4,9,10 3

81 28 2,4,10 3

81 30 2,4,10 3

81 32 2,4,10 3

81 34 2,4,10 3

81 36 10 3

81 38 10 3

82 13 9

3 82 15 2,9 3

82 17 2,9 3

82 19 2,4,9 3

82 21 2,4,9 3

82 23 2,4,9 3

82 25 2,4,9,10 3

82 27 2,4,10 3

82 29 2,4,10 3

82 31 2,4,10 3

83 12 9

3 83 14 9

3 83 16 2,9 3

83 18 2,4,9 3

83 20 2,4,9 3

83 22 2,4,9 3

83 24 2,4,9 3

84 13 9

3 84 15 2,9 A.2-18