- El. (feet) 289.71 288.66 285.42 280.14 272.96 264.12 253.87 242.54 230.46 227.38 224.28 221.15 218.00 215.00 210.00 200.00 190.00
- 180.00 170.00 160.00 150.00 140.00 130.00 120.00 110.00 100.00 92.00 84.00 76.00
- SGS-UFSAR TABLE 3.8-1 STRESSES IN HOOP REINFORCING BAR NO. 1 (KIPS/IN.2) Load Combination Critical A 51.75 46.36 38.80 4.48 55.45 49.58 41.41 4.54 56.46 50.60 42.35 4.13 55.27 49.69 41.52 3.26 56.07 50.72 42.63 4.24 56.19 51.29 43.42 4.27 55.87 51.56 43.94 3.30 55.54 51.87 44.55 3.57 55.38 52.34 45.21 3.82 58.50 56.00 48.51 4.36 57.35 55.65 48.27 4.45 54.42 53.80 46.99 4.47 48.15 49.17 44.28 4.72 37.46 40.20 34.44 3.44 24.04 28.78 24.78 -3.12 12.58 20.30 20.91 -4.62 4.59 10.83 6.05 -3.45 1 of 1 E Case -5.06 A -5.21 A -5.35 A -5.48 A -5.62 A -5.74 A -5.83 A -5.96 A -6.12 A -6.42 A -6.91 A -7.80 A -7.03 B -3.16 B -1.93 B -3.77 c -2.06 B Revision 6 February 15, 1987
- El. (feet) 289.71 288.66 285.42 280.14 272.96 264.12 253.87 242.54 230.46 227.38 224.28 221.15 218.00 215.00 210.00 200.00 190.00
- 180.00 170.00 160.00 150.00 140.00 130.00 120.00 110.00 100.00 92.00 84.00 76.00
- l;GS-UFSAR TABLE 3.8-2 STRESSES IN MERIDIONAL REINFORCING BAR NO. 1 (KIPS/IN.2) Load Combination A B c 54.12 47.53 38.58 56.63 49.10 39.69 49.56 43.25 35.13 55.96 48.80 39.65 50.16 44.15 36.02 52.09 45.89 37.48 52.12 46.02 37.66 52.25 46.35 38.05 52.53 46.83 38.56 52.29 46.80 38.62 52.39 47.02 38.86 48.97 44.02 36.44 42.67 38.40 31.87 43.69 39.47 32.87 43.02 39.26 32.87 42.28 39.24 33.15 41.39 39.24 33.51 40.59 39.41 34.03 39.79 39.63 34.63 38.96 39.89 35.29 38.61 40.64 36.37 38.51 41.67 37.70 37.97 42.34 38.76 37.79 43.39 40.13 34.68 41.78 39.32 26.86 35.52 34.84 14.23 19.96 18.76 18.79 25.71 25.82 19.29 19.49 15.59 1 of 1 D -1.77 -2.67 -2.51 -3.37 -2.80 -3.28 -3.77 -4.34 -4.88 -5.21 -5.42 -5.65 -5.89 -7.02 -7.49 -8.19 -9.08 -10.09 -11.19 -12.46 -13.72 -14.96 -16.19 -17.40 -18.60 -20.03 -13.83 -15.56 -11.99 Critical E Case -4.27 A -4.28 A -4.24 A -4.59 A -4.96 A -4.98 A -4.56 A -4.42 A -4.55 A -4.65 A -4.61 A -4.24 A -3.47 A -3.14 A -3.33 A -3.58 A -3.83 A -4.10 A -4.39 A -4.69 B -5.14 B -5.60 B -5.91 B -6.13 B -5.90 B -5.53 B -3.86 B -4.65 c -3.21 B Revision 6 February 15, 1987
- El. (feet) 289.71 288.66 285.42 280.14 272.96 264.12 253.87 242.54 230.46 227.38 224.28 221.15 218.00 215.00 210.00 200.00 190.00
- 180.00 170.00 160.00 150.00 140.00 130.00 120.00 110.00 100.00 92.00 84.00 76.00
- SGS-UFSAR TABLE 3.8-3 STRESSES IN HOOP REINFORCING BAR NO. 2 (KIPS/IN.2) Load Combination A 54.76 47.56 38.41 -2.25 53.77 46.83 37.94 -2.31 53.24 46.52 37.85 -2.47 53.59 47.00 38.38 2.31 53.89 47.46 38.92 2.81 53.95 47.74 39.37 3.43 53.89 47.98 39.83 4.25 47.61 42.75 35.69 4.00 49.54 44.51 37.26 4.54 50.42 45.32 37.99 4. 72 52.06 46.73 39.16 4.88 53.91 48.32 40.49 4.99 51.75 46.36 38.80 4.48 55.50 49.64 41.49 4.60 56.54 50.67 42.42 4.24 55.34 49.75 41.61 3.40 56.12 50.76 42.68 4.07 56.21 51.31 43.44 4.11 55.87 51.56 43.95 3.44 55.53 51.87 44.55 3.71 55.37 52.34 45.22 3.97 58.49 56.01 48.61 4.55 57.39 55.70 48.50 4.69 54.54 53.93 47.33 4.76 48.38 49.38 44.49 4.92 37.71 40.53 35.59 3.81 24.17 29.01 26.11 -3.49 12.46 20.27 21.30 -4.87 3.82 10.52 8.07 -3.70 1 of 1 Critical Case -4.36 A -4.35 A -4.33 A -4.29 A -4.22 A -4.11 A -3.99 A -3.93 A -4.01 A -4.04 A -4.48 A -4.78 A -5.06 A -5.22 A -5.36 A -5.50 A -5.63 A -5.75 A -5.83 A -5.96 A -6.13 A -6.44 A -6.97 A -7.86 A -7.04 B -3.42 B -2.31 B -3.93 c -2.35 B Revision 6 February 15, 1987
- El. (feet) 289.71 288.66 285.42 280.14 272.96 264. 12 253.87 242.54 230.46 227.38 224.28 221.15 218.00 215.00
- 210.00 200.00 190.00 180.00 170.00 160.00 150.00 140.00 130.00 120.00 110.00 100.00 92.00 84.00 76.00
- SGS-UFSAR TABLE 3.8-4 STRESSES IN MERIDIONAL REINFORCING BAR NO. 2 (KIPS/IN.2) Load Combination Critical 15.70 22.42 22.37 17.44 25.36 25.84 10.97 16.11 16.15 1 of 1 D -15 .OS -16.61 -10.89 E -4.55 -4.99 -2.31 Revision 6 February 15, 1987 Case B c c
- El. (feet) 289.71 288.66 285.42 280.14 272.96 264.12 253.87 242.54 230.46 227.38 224.28 221.15 218.00 215.00 210.00 200.00 190.00
- 180.00 170.00 160.00 150.00 140.00 130.00 120.00 110.00 100.00 92.00 84.00 76.00
- SGS-UFSAR TABLE 3.8-5 STRESSES IN HOOP REINFORCING BAR NO. 4 (KIPS/IN.2) Load Combination A B c D 46.98 42.17 35.21 4.00 48.93 43.95 36.80 4.54 49.78 44.73 37.50 4. 72 51.36 46.09 38.64 4.88 53.15 47.62 39.91 4.99 50.93 45.61 38.19 4.48 55.09 49.37 41.51 5.14 56.41 50.53 42.39 5.11 55.21 49.58 41.79 4.54 55.83 50.49 42.63 2.74 55.70 50.87 43.12 2.87 55.24 51.04 43.58 4.60 54.84 51.29 44.09 4.83 54.65 51.74 44.88 5.12 57.87 55.53 48.93 6.01 57.15 55.63 49.90 6.59 55.09 54.55 49.63 7.03 49.88 50.75 45.91 6.44 39.52 42.91 44.42 6.78 25.09 30.73 36.48 -6.37 11.48 20.02 24.32 -6.84 -2.36 -11.62 -26.43 6.76 1 of 1 Critical E Case 4.64 A 4.79 A 4.83 A 4.86 A 4.79 A 4.63 A 4.65 A 4.60 A 4.67 A 4.79 A 4.96 A 5.18 A 5.37 A 5.55 A 5. 71 A 5.65 A 5.21 A 4.45 c 5.43 c 5.27 c -3.65 B 6.26 c Revision 6 February 15, 1987
- El. (feet) 289.71 288.66 285.42 280.14 272.96 264.12 253.87 242.54 230.46 227.38 224.28 221.15 218.00 215.00 210.00 200.00 190.00
- 180.00 170.00 160.00 150.00 140.00 130.00 120.00 110.00 100.00 92.00 84.00 76.00
- SGS-UFSAR TABLE 3.8-6 STRESSES IN HOOP REINFORCING BAR NO. 5 (KIPS/IN.2) Load Combination D 48.60 41.93 33.75 -2.25 51.25 44.52 36.03 -2.31 51.85 45.25 36.80 -2.47 52.57 46.07 37.62 2.31 53.04 46.68 38.28 2.81 53.19 47.05 38.79 3.43 53.19 47.35 39.30 4.25 46.98 42.17 35.21 4.00 48.93 43.95 36.80 4.54 49.78 44.73 37.50 4.72 51.36 46.09 38.64 4.88 53.15 47.62 39.91 4.99 50.93 45.61 38.19 4.48 55.14 49.42 41.59 5.21 56.48 50.60 42.46 5.22 55.28 49.64 41.88 4.68 55.88 50.53 42.69 2.57 55.72 50.89 43.14 2. 71 55.24 51.05 43.59 4.75 54.83 51.29 44.09 4.97 54.64 51.74 44.90 5.27 57.86 55.54 49.02 6.20 57.19 55.68 50.13 6.83 55.21 54.68 49.97 7.31 50.12 50.96 46.12 6.64 39.77 43.24 45.57 7.16 25.22 30.96 37.81 -6.74 11.36 19.99 24.72 -7.09 -3.13 -12.52 -29.32 7.37 1 of 1 Critical E Case 3.68 A 3.73 A 3.80 A 3.90 A 4.02 A 4.21 A 4.45 A 4.64 A 4.79 A 4.83 A 4.86 A 4.79 A 4.63 A 4.66 A 4.60 A 4.68 A 4.79 A 4.96 A 5.18 A 5.37 A 5.56 A 5.74 A 5.71 A 5.28 A 4.47 B 5.70 c 5.62 c -3.80 c 7.03 c Revision 6 February 15, 1987
- El.(feet) 289.71 288.66 285.42 280.14 272.96 264.12 253.87 242.54 230.46 227.38 224.28 221.15 218.00 215.00 210.00 200.00 190.00
- 180.00 170.00 160.00 150.00 140.00 130.00 120.00 110.00 100.00 92.00 84.00 76.00
- SGS-UFSAR TABLE 3.8-7 STRESSES IN MERIDIONAL REINFORCING BAR NO. 5 (KIPS/IN.2) Load Combination A B c 47.15 41.15 33.31 -1.77 56.19 48.70 39.36 -2.67 49.27 42.99 34.91 -2.51 55.62 48.48 39.39 -3.37 49.83 43.84 35.76 -2.80 52.08 45.88 37.48 -3.28 52.32 46.20 37.80 -3.77 52.36 46.45 38.13 -4.34 53.19 47.43 39.06 -4.88 52.88 47.34 39.07 -5.21 51.51 46.21 38.19 -5.42 46.82 42.05 34.81 -5.65 40.54 36.46 30.26 -5.89 42.17 38.08 31.71 -7.02 41.96 38.29 32.07 -7.49 41.49 38.52 32.55 -8.19 40.63 38.55 32.93 -9.08 39.96 38.83 33.55 -10.09 39.33 39.21 34.28 -11.19 38.74 39.69 35.12 -12.46 38.52 40.56 36.30 -13.72 38.54 41.70 37.72 -14.96 38.12 42.48 38.87 -16.19 37.69 43.29 40.05 -17.40 34.39 41.52 39.10 -18.60 26.80 35.47 34.80 -20.03 15.15 22.35 22.93 -15.52 13.98 22.53 23.62 -17.02 5.90 12.27 13.60 -10.68 1 of 1 Critical E Case 4. 77 A 3.60 A 3.57 A 3.88 A 4.24 A 4.18 A 3.67 A 3.44 A 3.50 A 3.52 A 3.31 A 2.75 A 1.84 A 1.43 A 1.52 A 1.59 A 1.65 A 1. 71 A 1. 79 A 1.90 B 2.12 B 2.39 B 2.57 B 2.73 B -2.47 B 2.65 B -3.41 c -4.99 c -3.71 c Revision 6 February 15, 1987
- *
- TABLE 3.8-8 STRESSES IN DIAGONAL SEISMIC REINFORCING BAR NO. 3 (KIPS/IN.2) Load Combination El. (feet) A B c D 289.71 288.06 285.42 280.14 272.96 264.12 253.87 242.54 29.70 38.30 -21.94 230.46 35.58 45.85 -24.89 227.38 38.83 50.01 -26.03 224.28 41.03 52.83 -26.95 221.15 43.43 55.89 -27.90 218.00 45.97 59.14 -28.85 215.00 31.16 40.06 -18.94 210.00 33.87 43.49 -19.44 200.00 38.08 48.79 -20.24 190.00 42.00 53.67 -21.20 180.00 31.71 40.40 -16.04 170.00 34.01 43.17 -17.29 160.00 36.16 45.72 -20.43 150.00 38.19 48.07 -23.69 140.00 40.10 50.23 -26.98 130.00 41.84 52.25 -30.16 120.00 43.36 54.20 -32.78 110.00 44.50 56.15 -34.11 100.00 36.82 46.63 -27.02 92.00 39.96 51.33 -27.02 84.00 44.26 60.79 -27.02 76.00 31.59 44.44 -27.02 1 of 1 SGS-UFSAR Critical E Case 38.30 C & E 45.85 C & E 50.01 C & E 52.83 C & E 55.89 C & E 59.14 C & E 40.06 C & E 43.49 C & E 48.79 C & E 53.67 C & E 40.40 C & E 43.17 C & E 45.72 C & E 48.07 C & E 50.23 C & E 52.25 C & E 54.20 C & E 56.15 C & E 46.63 C & E 51.33 C & E 60. 79. C & E 44.44 C & E Revision 6 February 15, 1987
- El. (feet) 289.71 288.66 285.42 280.14 272.96 264.12 253.87 242.54 230.46 227.38 224.28 221.15 218.00 215.00 210.00 200.00 190.00 180.00
- 170.00 160.00 150.00 140.00 130.00 120.00 110.00 100.00 92.00 84.00 76.00
- SGS-UFSAR TABLE 3.8-9 MAXIMUM TENSILE STRESSES IN LINEAR PLATE (KIPS/IN.2) Load Combination Test c Pressure 22.8 24.6 20.5 23.2 21.0 21.6 22.3 20.3 20.1 21.6 23.3 25.2 24.2 26.4 27.6 27.6 28.8 28.3 28.3 28.2 28.4 30.8 30.9 30.1 27.3 22.6 26.4 25.6 20.7 22.4 27.5 27.3 13.4 17.2 24.8 26.9 10.9 26.0 24.1 22.6 21.6 1 of 1 Critical Case Test Pressure Test Pressure Test Pressure Test Pressure Test Pressure Test Pressure Test Pressure Test Pressure Test Pressure Test Pressure Test Pressure Test Pressure Test Pressure Test Pressure Test Pressure Test Pressure Test Pressure Test Pressure Test Pressure Test Pressure Test Pressure Test Pressure Test Pressure Test Pressure Test Pressure B B c A Revision 6 February 15, 1987
- *
- TABLE 3.8-10 INTERACTION COEFFICIENT FOR LINER PLATE IN COMPRESSION Load Combination Critical El.(feet) A B c 289.71 .163 .225 .213 288.66 .019 .108 .123 285.42 .128 .194 .190 280.14 .063 .143 .151 272.96 .191 .251 .237 264.12 .153 .223 .216 253.87 .093 .175 .181 242.54 .144 .227 .230 230.46 .127 .223 .237 227.38 .116 .223 .243 224.28 .048 .177 .210 221.15 .038 .170 .210 218.00 .106 .235 .269 215.00 .029 .204 .272 210.00 .055 .245 .318 200.00 .107 .317 .400 190.00 .103 .345 .447 180.00 .101 .372 .492 170.00 .113 .412 .545 160.00 .131 .455 .601 150.00 .158 .507 .662 140.00 .135 .516 .688 130.00 .180 .582 .759 120.00 .325 .732 .902 110.00 .136 .569 .791 100.00 * .059 .419 92.00 * * .186 84.00 * .051 .473 76.00 * * .157 *Liner is in tension 1 of 1 SGS-UFSAR D .026 .029 .023 .018 .010 .005 .000 .009 .015 .023 .025 .027 .035 .048 .054 .074 .095 .117 .139 .172 .208 .247 .292 .339 .381 .415 .276 .293 .344 E Case .282 E .283 E .284 E .285 E .287 E .290 E .297 E .311 E .333 E .346 E .345 E .349 E .358 E .409 E .435 E .475 E .516 E .556 E .595 E .634 E .673 E .715 E . 759 E .814 c .787 c .683 E .517 A .723 E .454 E Revision 6 February 15, 1987 TABLE 3.8-11
SUMMARY
OF FOUNDATIONS
1 of 2 SGS-UFSAR Revision 6 February 15, 1987
TABLE 3.8-11 (Cont.)
2 of 2 SGS-UFSAR Revision 6 February 15, 1987