LR-N23-0050 LAR S23-04 LAR H23-02 Salem PAVAN Output File filename: output SGS 695m and 790m

LR-N23-0050 LAR S23-04 LAR H23-02

LR-N23-0050 LAR S23-04 LAR H23-02 USNRC COMPUTER CODE-PAVAN, VERSION 2.0 RUN DATE: 03-03-2023 PRINTOUT OF INPUT CARDS 1 00010 00010 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 2 SGS EAB 2019-2021 Ground Level 3 10 m 10 m - 46 m 4 A-5-ZZ-MDC-2391 5 695 m and 790 m EAB 6 11 24984 0 7 0.500 2399.000 58.300 10.000 10.000 8 0.000 0.000 0.000 0.000 0.000 0.000 0.000 9 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 9 0.000 2.000 0.000 2.000 1.000 2.000 3.000 2.000 1.000 3.000 0.000 3.000 1.000 0.000 2.000 1.000 9 4.000 4.000 7.000 11.000 3.000 3.000 2.000 5.000 9.000 5.000 2.000 1.000 2.000 5.000 3.000 3.000 9 5.000 7.000 19.000 16.000 11.000 5.000 4.000 9.000 5.000 8.000 5.000 4.000 1.000 9.000 6.000 2.000 9 22.000 24.000 50.000 44.000 37.000 19.000 23.000 21.000 14.000 12.000 26.000 35.000 10.000 18.000 23.000 14.000 9 28.000 39.000 74.000 37.000 27.000 14.000 46.000 33.000 22.000 11.000 35.000 49.000 27.000 21.000 35.000 26.000 9 39.000 34.000 23.000 25.000 18.000 14.000 85.000 43.000 26.000 5.000 26.000 47.000 47.000 34.000 59.000 49.000 9 25.000 23.000 15.000 12.000 7.000 9.000 85.000 38.000 12.000 14.000 5.000 20.000 33.000 40.000102.000 56.000 9 33.000 17.000 6.000 15.000 4.000 11.000 94.000 45.000 10.000 4.000 1.000 4.000 56.000 52.000111.000 69.000 9 6.000 1.000 0.000 0.000 0.000 0.000 12.000 7.000 3.000 1.000 1.000 0.000 17.000 34.000 75.000 25.000 9 0.000 0.000 0.000 0.000 0.000 0.000 12.000 2.000 1.000 1.000 0.000 0.000 5.000 11.000 7.000 0.000 9 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 1.000 0.000 1.000 0.000 9 0.000 0.000 0.000 1.000 0.000 2.000 2.000 0.000 0.000 0.000 1.000 0.000 0.000 1.000 0.000 0.000 9 0.000 2.000 4.000 4.000 3.000 0.000 2.000 0.000 0.000 1.000 0.000 0.000 1.000 1.000 0.000 1.000 9 0.000 0.000 3.000 3.000 3.000 1.000 3.000 0.000 0.000 2.000 3.000 4.000 1.000 2.000 2.000 2.000 9 10.000 8.000 11.000 12.000 8.000 2.000 7.000 16.000 7.000 11.000 8.000 3.000 12.000 7.000 5.000 3.000 9 4.000 10.000 7.000 8.000 3.000 8.000 15.000 10.000 9.000 9.000 7.000 12.000 11.000 7.000 19.000 9.000 9 12.000 15.000 5.000 6.000 0.000 4.000 16.000 5.000 5.000 3.000 5.000 6.000 11.000 7.000 15.000 12.000 9 4.000 11.000 6.000 1.000 0.000 2.000 24.000 7.000 2.000 1.000 1.000 3.000 14.000 11.000 22.000 16.000 9 4.000 8.000 4.000 4.000 0.000 4.000 18.000 5.000 9.000 0.000 1.000 2.000 12.000 26.000 41.000 16.000 9 1.000 0.000 0.000 0.000 0.000 0.000 7.000 0.000 1.000 0.000 0.000 0.000 2.000 11.000 16.000 4.000 9 0.000 0.000 0.000 0.000 0.000 0.000 1.000 0.000 0.000 0.000 0.000 0.000 1.000 4.000 0.000 0.000 9 0.000 1.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 9 0.000 1.000 1.000 0.000 0.000 0.000 0.000 0.000 1.000 2.000 0.000 1.000 1.000 0.000 1.000 0.000 9 3.000 1.000 4.000 1.000 5.000 0.000 0.000 1.000 1.000 3.000 2.000 0.000 1.000 1.000 1.000 0.000 9 2.000 3.000 3.000 7.000 5.000 3.000 1.000 0.000 1.000 3.000 2.000 3.000 2.000 0.000 6.000 1.000 9 16.000 9.000 21.000 20.000 9.000 8.000 8.000 19.000 13.000 22.000 21.000 12.000 13.000 11.000 13.000 8.000 9 9.000 11.000 15.000 14.000 8.000 7.000 15.000 12.000 11.000 6.000 10.000 9.000 14.000 8.000 12.000 20.000

LR-N23-0050 LAR S23-04 LAR H23-02 9 17.000 16.000 11.000 1.000 2.000 6.000 22.000 14.000 9.000 5.000 7.000 9.000 11.000 8.000 29.000 24.000 9 3.000 15.000 2.000 2.000 0.000 1.000 18.000 7.000 10.000 2.000 0.000 3.000 5.000 12.000 25.000 23.000 9 5.000 6.000 2.000 1.000 0.000 2.000 17.000 9.000 16.000 1.000 1.000 4.000 4.000 19.000 28.000 17.000 9 1.000 0.000 0.000 0.000 0.000 0.000 2.000 0.000 1.000 0.000 0.000 0.000 2.000 7.000 8.000 5.000 9 0.000 0.000 0.000 0.000 0.000 0.000 1.000 3.000 0.000 0.000 0.000 0.000 1.000 1.000 0.000 0.000 9 0.000 1.000 1.000 0.000 1.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 1.000 0.000 0.000 1.000 9 8.000 10.000 4.000 9.000 7.000 6.000 6.000 3.000 3.000 4.000 3.000 2.000 5.000 3.000 4.000 7.000 9 13.000 17.000 37.000 28.000 22.000 9.000 7.000 18.000 20.000 22.000 12.000 12.000 9.000 21.000 14.000 12.000 9 33.000 35.000 53.000 47.000 32.000 23.000 16.000 27.000 37.000 36.000 29.000 29.000 30.000 26.000 27.000 16.000 9 85.000104.000153.000 77.000 51.000 45.000 68.000 76.000124.000122.000107.000 77.000 53.000 79.000 76.000115.000 9 80.000 93.000 91.000 40.000 29.000 29.000 86.000 85.000105.000105.000 91.000113.000 59.000 75.000121.000132.000 9 63.000 78.000 64.000 25.000 14.000 20.000109.000102.000114.000 79.000 31.000 57.000 88.000 78.000127.000 91.000 9 43.000 63.000 28.000 9.000 2.000 3.000101.000101.000 99.000 29.000 11.000 38.000 52.000 60.000115.000 94.000 9 26.000 28.000 16.000 2.000 3.000 4.000113.000 84.000 75.000 11.000 7.000 27.000 67.000 91.000178.000102.000 9 2.000 1.000 2.000 0.000 0.000 3.000 19.000 8.000 8.000 0.000 0.000 3.000 22.000 28.000 34.000 14.000 9 0.000 0.000 0.000 0.000 1.000 0.000 21.000 2.000 3.000 0.000 0.000 0.000 8.000 5.000 3.000 1.000 9 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 1.000 1.000 0.000 0.000 0.000 9 21.000 14.000 21.000 27.000 17.000 10.000 6.000 10.000 7.000 13.000 11.000 13.000 11.000 21.000 17.000 18.000 9 44.000 42.000 40.000 45.000 51.000 30.000 15.000 20.000 22.000 36.000 38.000 45.000 39.000 49.000 41.000 40.000 9 64.000 55.000 83.000 77.000 76.000 44.000 37.000 58.000 51.000 81.000 89.000 75.000 60.000 86.000 70.000 72.000 9 143.000162.000146.000 99.000 99.000103.000135.000125.000129.000227.000305.000262.000191.000172.000226.000177.000 9 116.000104.000 69.000 32.000 29.000 83.000170.000121.000 92.000160.000194.000226.000153.000149.000204.000133.000 9 95.000 45.000 37.000 11.000 4.000 20.000167.000105.000 81.000 87.000 60.000 63.000 74.000 90.000194.000112.000 9 24.000 16.000 16.000 6.000 2.000 6.000100.000 63.000 46.000 48.000 29.000 18.000 24.000 28.000114.000 62.000 9 11.000 9.000 1.000 1.000 0.000 0.000 64.000 33.000 28.000 22.000 19.000 5.000 27.000 36.000 92.000 48.000 9 2.000 1.000 0.000 0.000 0.000 0.000 13.000 7.000 7.000 1.000 0.000 2.000 9.000 13.000 12.000 4.000 9 0.000 0.000 0.000 0.000 0.000 0.000 2.000 1.000 2.000 0.000 0.000 0.000 3.000 1.000 0.000 0.000 9 0.000 0.000 0.000 2.000 1.000 0.000 2.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 2.000 0.000 9 10.000 15.000 14.000 12.000 13.000 10.000 4.000 3.000 6.000 3.000 13.000 7.000 9.000 11.000 11.000 9.000 9 27.000 23.000 30.000 46.000 37.000 13.000 14.000 11.000 16.000 16.000 13.000 10.000 16.000 17.000 23.000 24.000 9 35.000 34.000 52.000 33.000 45.000 25.000 20.000 26.000 18.000 19.000 34.000 22.000 32.000 22.000 44.000 34.000 9 147.000114.000 80.000 41.000 32.000 87.000 74.000 60.000 30.000 30.000 93.000 77.000 48.000 42.000175.000105.000 9 65.000 47.000 25.000 4.000 3.000 18.000 78.000 38.000 14.000 20.000 40.000 45.000 27.000 21.000 79.000 48.000 9 16.000 9.000 1.000 2.000 0.000 1.000 49.000 12.000 11.000 14.000 28.000 19.000 7.000 1.000 9.000 9.000 9 21.000 1.000 0.000 0.000 0.000 0.000 33.000 9.000 7.000 16.000 19.000 5.000 0.000 0.000 1.000 4.000 9 2.000 1.000 0.000 0.000 0.000 0.000 38.000 7.000 12.000 20.000 13.000 1.000 1.000 0.000 0.000 0.000 9 0.000 0.000 1.000 0.000 0.000 0.000 6.000 4.000 8.000 6.000 5.000 0.000 0.000 0.000 0.000 0.000 9 0.000 0.000 0.000 0.000 0.000 0.000 6.000 2.000 5.000 2.000 0.000 0.000 0.000 0.000 0.000 0.000 9 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 1.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 9 2.000 4.000 11.000 12.000 7.000 5.000 3.000 4.000 7.000 5.000 2.000 0.000 5.000 1.000 1.000 4.000 9 11.000 21.000 17.000 31.000 34.000 15.000 8.000 15.000 10.000 7.000 4.000 2.000 5.000 4.000 7.000 12.000

LR-N23-0050 LAR S23-04 LAR H23-02 9 15.000 27.000 19.000 19.000 23.000 23.000 19.000 12.000 7.000 7.000 2.000 4.000 5.000 6.000 11.000 10.000 9 58.000 59.000 48.000 18.000 20.000 51.000 64.000 23.000 12.000 13.000 21.000 11.000 3.000 1.000 21.000 36.000 9 52.000 32.000 10.000 3.000 0.000 3.000 56.000 22.000 9.000 9.000 12.000 4.000 0.000 1.000 9.000 22.000 9 9.000 4.000 2.000 0.000 0.000 0.000 45.000 18.000 10.000 15.000 7.000 1.000 0.000 0.000 0.000 1.000 9 1.000 1.000 0.000 0.000 0.000 0.000 45.000 9.000 3.000 10.000 5.000 0.000 0.000 0.000 0.000 0.000 9 0.000 0.000 0.000 0.000 0.000 0.000 35.000 10.000 9.000 8.000 0.000 0.000 0.000 0.000 0.000 0.000 9 0.000 0.000 0.000 0.000 0.000 0.000 2.000 0.000 9.000 8.000 0.000 0.000 0.000 0.000 0.000 0.000 9 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 4.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 10 -1. 0.500 1.050 1.550 2.050 3.050 4.050 5.050 6.050 8.050 10.000 15.000 0.000 0.000 0.000 11 695. 695. 695. 695. 695. 695. 695. 695. 695. 695. 695. 695. 695. 695. 695. 695.

11 790. 790. 790. 790. 790. 790. 790. 790. 790. 790. 790. 790. 790. 790. 790. 790.

12 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 12 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0

LR-N23-0050 LAR S23-04 LAR H23-02 USNRC COMPUTER CODE-PAVAN, VERSION 2.0 RUN DATE: 03-03-2023 PLANT NAME: SGS EAB METEOROLOGICAL INSTRUMENTATION DATA PERIOD: 2019-2021 WIND SENSORS HEIGHT: 10 m TYPE OF RELEASE: Ground Level DELTA-T HEIGHTS: 10 m - 46 m SOURCE OF DATA: A-5-ZZ-MDC-2391 COMMENTS: 695 m and 790 m EAB PROGRAM: PAVAN, 10/76, 8/79 REVISION, IMPLEMENTATION OF REGULATORY GUIDE 1.145 JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION ATMOSPHERIC STABILITY CLASS A WIND SPEED (M/S)

TOWER RELEASE N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL 0.50 0.50 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 1.05 1.05 0.000 0.008 0.000 0.008 0.004 0.008 0.012 0.008 0.004 0.012 0.000 0.012 0.004 0.000 0.008 0.004 0.092 1.55 1.55 0.016 0.016 0.028 0.044 0.012 0.012 0.008 0.020 0.036 0.020 0.008 0.004 0.008 0.020 0.012 0.012 0.276 2.05 2.05 0.020 0.028 0.076 0.064 0.044 0.020 0.016 0.036 0.020 0.032 0.020 0.016 0.004 0.036 0.024 0.008 0.464 3.05 3.05 0.088 0.096 0.200 0.176 0.148 0.076 0.092 0.084 0.056 0.048 0.104 0.140 0.040 0.072 0.092 0.056 1.569 4.05 4.05 0.112 0.156 0.296 0.148 0.108 0.056 0.184 0.132 0.088 0.044 0.140 0.196 0.108 0.084 0.140 0.104 2.097 5.05 5.05 0.156 0.136 0.092 0.100 0.072 0.056 0.340 0.172 0.104 0.020 0.104 0.188 0.188 0.136 0.236 0.196 2.297 6.05 6.05 0.100 0.092 0.060 0.048 0.028 0.036 0.340 0.152 0.048 0.056 0.020 0.080 0.132 0.160 0.408 0.224 1.985 8.05 8.05 0.132 0.068 0.024 0.060 0.016 0.044 0.376 0.180 0.040 0.016 0.004 0.016 0.224 0.208 0.444 0.276 2.129 10.00 10.00 0.024 0.004 0.000 0.000 0.000 0.000 0.048 0.028 0.012 0.004 0.004 0.000 0.068 0.136 0.300 0.100 0.728 15.00 15.00 0.000 0.000 0.000 0.000 0.000 0.000 0.048 0.008 0.004 0.004 0.000 0.000 0.020 0.044 0.028 0.000 0.156 TOTAL 0.648 0.604 0.776 0.648 0.432 0.308 1.465 0.821 0.412 0.256 0.404 0.652 0.797 0.897 1.693 0.981 11.796 JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION ATMOSPHERIC STABILITY CLASS B WIND SPEED (M/S)

LR-N23-0050 LAR S23-04 LAR H23-02 TOWER RELEASE N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL 0.50 0.50 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.004 0.000 0.004 0.000 0.008 1.05 1.05 0.000 0.000 0.000 0.004 0.000 0.008 0.008 0.000 0.000 0.000 0.004 0.000 0.000 0.004 0.000 0.000 0.028 1.55 1.55 0.000 0.008 0.016 0.016 0.012 0.000 0.008 0.000 0.000 0.004 0.000 0.000 0.004 0.004 0.000 0.004 0.076 2.05 2.05 0.000 0.000 0.012 0.012 0.012 0.004 0.012 0.000 0.000 0.008 0.012 0.016 0.004 0.008 0.008 0.008 0.116 3.05 3.05 0.040 0.032 0.044 0.048 0.032 0.008 0.028 0.064 0.028 0.044 0.032 0.012 0.048 0.028 0.020 0.012 0.520 4.05 4.05 0.016 0.040 0.028 0.032 0.012 0.032 0.060 0.040 0.036 0.036 0.028 0.048 0.044 0.028 0.076 0.036 0.592 5.05 5.05 0.048 0.060 0.020 0.024 0.000 0.016 0.064 0.020 0.020 0.012 0.020 0.024 0.044 0.028 0.060 0.048 0.508 6.05 6.05 0.016 0.044 0.024 0.004 0.000 0.008 0.096 0.028 0.008 0.004 0.004 0.012 0.056 0.044 0.088 0.064 0.500 8.05 8.05 0.016 0.032 0.016 0.016 0.000 0.016 0.072 0.020 0.036 0.000 0.004 0.008 0.048 0.104 0.164 0.064 0.616 10.00 10.00 0.004 0.000 0.000 0.000 0.000 0.000 0.028 0.000 0.004 0.000 0.000 0.000 0.008 0.044 0.064 0.016 0.168 15.00 15.00 0.000 0.000 0.000 0.000 0.000 0.000 0.004 0.000 0.000 0.000 0.000 0.000 0.004 0.016 0.000 0.000 0.024 TOTAL 0.140 0.216 0.160 0.156 0.068 0.092 0.380 0.172 0.132 0.108 0.104 0.120 0.264 0.308 0.484 0.252 3.158 JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION ATMOSPHERIC STABILITY CLASS C WIND SPEED (M/S)

TOWER RELEASE N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL 0.50 0.50 0.000 0.004 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.004 1.05 1.05 0.000 0.004 0.004 0.000 0.000 0.000 0.000 0.000 0.004 0.008 0.000 0.004 0.004 0.000 0.004 0.000 0.032 1.55 1.55 0.012 0.004 0.016 0.004 0.020 0.000 0.000 0.004 0.004 0.012 0.008 0.000 0.004 0.004 0.004 0.000 0.096 2.05 2.05 0.008 0.012 0.012 0.028 0.020 0.012 0.004 0.000 0.004 0.012 0.008 0.012 0.008 0.000 0.024 0.004 0.168

LR-N23-0050 LAR S23-04 LAR H23-02 3.05 3.05 0.064 0.036 0.084 0.080 0.036 0.032 0.032 0.076 0.052 0.088 0.084 0.048 0.052 0.044 0.052 0.032 0.893 4.05 4.05 0.036 0.044 0.060 0.056 0.032 0.028 0.060 0.048 0.044 0.024 0.040 0.036 0.056 0.032 0.048 0.080 0.724 5.05 5.05 0.068 0.064 0.044 0.004 0.008 0.024 0.088 0.056 0.036 0.020 0.028 0.036 0.044 0.032 0.116 0.096 0.764 6.05 6.05 0.012 0.060 0.008 0.008 0.000 0.004 0.072 0.028 0.040 0.008 0.000 0.012 0.020 0.048 0.100 0.092 0.512 8.05 8.05 0.020 0.024 0.008 0.004 0.000 0.008 0.068 0.036 0.064 0.004 0.004 0.016 0.016 0.076 0.112 0.068 0.528 10.00 10.00 0.004 0.000 0.000 0.000 0.000 0.000 0.008 0.000 0.004 0.000 0.000 0.000 0.008 0.028 0.032 0.020 0.104 15.00 15.00 0.000 0.000 0.000 0.000 0.000 0.000 0.004 0.012 0.000 0.000 0.000 0.000 0.004 0.004 0.000 0.000 0.024 TOTAL 0.224 0.252 0.236 0.184 0.116 0.108 0.336 0.260 0.252 0.176 0.172 0.164 0.216 0.268 0.492 0.392 3.850 JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION ATMOSPHERIC STABILITY CLASS D WIND SPEED (M/S)

TOWER RELEASE N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL 0.50 0.50 0.000 0.004 0.004 0.000 0.004 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.004 0.000 0.000 0.004 0.020 1.05 1.05 0.032 0.040 0.016 0.036 0.028 0.024 0.024 0.012 0.012 0.016 0.012 0.008 0.020 0.012 0.016 0.028 0.336 1.55 1.55 0.052 0.068 0.148 0.112 0.088 0.036 0.028 0.072 0.080 0.088 0.048 0.048 0.036 0.084 0.056 0.048 1.093 2.05 2.05 0.132 0.140 0.212 0.188 0.128 0.092 0.064 0.108 0.148 0.144 0.116 0.116 0.120 0.104 0.108 0.064 1.985 3.05 3.05 0.340 0.416 0.612 0.308 0.204 0.180 0.272 0.304 0.496 0.488 0.428 0.308 0.212 0.316 0.304 0.460 5.652 4.05 4.05 0.320 0.372 0.364 0.160 0.116 0.116 0.344 0.340 0.420 0.420 0.364 0.452 0.236 0.300 0.484 0.528 5.339 5.05 5.05 0.252 0.312 0.256 0.100 0.056 0.080 0.436 0.408 0.456 0.316 0.124 0.228 0.352 0.312 0.508 0.364 4.563 6.05 6.05 0.172 0.252 0.112 0.036 0.008 0.012 0.404 0.404 0.396 0.116 0.044 0.152 0.208 0.240 0.460 0.376 3.394 8.05 8.05 0.104 0.112 0.064 0.008 0.012 0.016 0.452 0.336 0.300 0.044 0.028 0.108 0.268 0.364 0.712 0.408 3.338

LR-N23-0050 LAR S23-04 LAR H23-02 10.00 10.00 0.008 0.004 0.008 0.000 0.000 0.012 0.076 0.032 0.032 0.000 0.000 0.012 0.088 0.112 0.136 0.056 0.576 15.00 15.00 0.000 0.000 0.000 0.000 0.004 0.000 0.084 0.008 0.012 0.000 0.000 0.000 0.032 0.020 0.012 0.004 0.176 TOTAL 1.413 1.721 1.797 0.949 0.648 0.568 2.185 2.025 2.354 1.633 1.165 1.433 1.577 1.865 2.798 2.341 26.473 JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION ATMOSPHERIC STABILITY CLASS E WIND SPEED (M/S)

TOWER RELEASE N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL 0.50 0.50 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.004 0.004 0.000 0.000 0.000 0.008 1.05 1.05 0.084 0.056 0.084 0.108 0.068 0.040 0.024 0.040 0.028 0.052 0.044 0.052 0.044 0.084 0.068 0.072 0.949 1.55 1.55 0.176 0.168 0.160 0.180 0.204 0.120 0.060 0.080 0.088 0.144 0.152 0.180 0.156 0.196 0.164 0.160 2.390 2.05 2.05 0.256 0.220 0.332 0.308 0.304 0.176 0.148 0.232 0.204 0.324 0.356 0.300 0.240 0.344 0.280 0.288 4.315 3.05 3.05 0.572 0.648 0.584 0.396 0.396 0.412 0.540 0.500 0.516 0.909 1.221 1.049 0.764 0.688 0.905 0.708 10.811 4.05 4.05 0.464 0.416 0.276 0.128 0.116 0.332 0.680 0.484 0.368 0.640 0.776 0.905 0.612 0.596 0.817 0.532 8.145 5.05 5.05 0.380 0.180 0.148 0.044 0.016 0.080 0.668 0.420 0.324 0.348 0.240 0.252 0.296 0.360 0.776 0.448 4.983 6.05 6.05 0.096 0.064 0.064 0.024 0.008 0.024 0.400 0.252 0.184 0.192 0.116 0.072 0.096 0.112 0.456 0.248 2.410 8.05 8.05 0.044 0.036 0.004 0.004 0.000 0.000 0.256 0.132 0.112 0.088 0.076 0.020 0.108 0.144 0.368 0.192 1.585 10.00 10.00 0.008 0.004 0.000 0.000 0.000 0.000 0.052 0.028 0.028 0.004 0.000 0.008 0.036 0.052 0.048 0.016 0.284 15.00 15.00 0.000 0.000 0.000 0.000 0.000 0.000 0.008 0.004 0.008 0.000 0.000 0.000 0.012 0.004 0.000 0.000 0.036 TOTAL 2.081 1.793 1.653 1.193 1.113 1.185 2.838 2.173 1.861 2.702 2.982 2.842 2.370 2.582 3.882 2.666 35.915 JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION ATMOSPHERIC STABILITY CLASS F WIND SPEED (M/S)

LR-N23-0050 LAR S23-04 LAR H23-02 TOWER RELEASE N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL 0.50 0.50 0.000 0.000 0.000 0.008 0.004 0.000 0.008 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.008 0.000 0.028 1.05 1.05 0.040 0.060 0.056 0.048 0.052 0.040 0.016 0.012 0.024 0.012 0.052 0.028 0.036 0.044 0.044 0.036 0.600 1.55 1.55 0.108 0.092 0.120 0.184 0.148 0.052 0.056 0.044 0.064 0.064 0.052 0.040 0.064 0.068 0.092 0.096 1.345 2.05 2.05 0.140 0.136 0.208 0.132 0.180 0.100 0.080 0.104 0.072 0.076 0.136 0.088 0.128 0.088 0.176 0.136 1.981 3.05 3.05 0.588 0.456 0.320 0.164 0.128 0.348 0.296 0.240 0.120 0.120 0.372 0.308 0.192 0.168 0.700 0.420 4.943 4.05 4.05 0.260 0.188 0.100 0.016 0.012 0.072 0.312 0.152 0.056 0.080 0.160 0.180 0.108 0.084 0.316 0.192 2.289 5.05 5.05 0.064 0.036 0.004 0.008 0.000 0.004 0.196 0.048 0.044 0.056 0.112 0.076 0.028 0.004 0.036 0.036 0.752 6.05 6.05 0.084 0.004 0.000 0.000 0.000 0.000 0.132 0.036 0.028 0.064 0.076 0.020 0.000 0.000 0.004 0.016 0.464 8.05 8.05 0.008 0.004 0.000 0.000 0.000 0.000 0.152 0.028 0.048 0.080 0.052 0.004 0.004 0.000 0.000 0.000 0.380 10.00 10.00 0.000 0.000 0.004 0.000 0.000 0.000 0.024 0.016 0.032 0.024 0.020 0.000 0.000 0.000 0.000 0.000 0.120 15.00 15.00 0.000 0.000 0.000 0.000 0.000 0.000 0.024 0.008 0.020 0.008 0.000 0.000 0.000 0.000 0.000 0.000 0.060 TOTAL 1.293 0.977 0.813 0.560 0.524 0.616 1.297 0.688 0.508 0.584 1.033 0.744 0.560 0.456 1.377 0.933 12.964 JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION ATMOSPHERIC STABILITY CLASS G WIND SPEED (M/S)

TOWER RELEASE N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL 0.50 0.50 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.004 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.004 1.05 1.05 0.008 0.016 0.044 0.048 0.028 0.020 0.012 0.016 0.028 0.020 0.008 0.000 0.020 0.004 0.004 0.016 0.292 1.55 1.55 0.044 0.084 0.068 0.124 0.136 0.060 0.032 0.060 0.040 0.028 0.016 0.008 0.020 0.016 0.028 0.048 0.813 2.05 2.05 0.060 0.108 0.076 0.076 0.092 0.092 0.076 0.048 0.028 0.028 0.008 0.016 0.020 0.024 0.044 0.040 0.837

LR-N23-0050 LAR S23-04 LAR H23-02 3.05 3.05 0.232 0.236 0.192 0.072 0.080 0.204 0.256 0.092 0.048 0.052 0.084 0.044 0.012 0.004 0.084 0.144 1.837 4.05 4.05 0.208 0.128 0.040 0.012 0.000 0.012 0.224 0.088 0.036 0.036 0.048 0.016 0.000 0.004 0.036 0.088 0.977 5.05 5.05 0.036 0.016 0.008 0.000 0.000 0.000 0.180 0.072 0.040 0.060 0.028 0.004 0.000 0.000 0.000 0.004 0.448 6.05 6.05 0.004 0.004 0.000 0.000 0.000 0.000 0.180 0.036 0.012 0.040 0.020 0.000 0.000 0.000 0.000 0.000 0.296 8.05 8.05 0.000 0.000 0.000 0.000 0.000 0.000 0.140 0.040 0.036 0.032 0.000 0.000 0.000 0.000 0.000 0.000 0.248 10.00 10.00 0.000 0.000 0.000 0.000 0.000 0.000 0.008 0.000 0.036 0.032 0.000 0.000 0.000 0.000 0.000 0.000 0.076 15.00 15.00 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.016 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.016 TOTAL 0.592 0.592 0.428 0.332 0.336 0.388 1.109 0.452 0.324 0.328 0.212 0.088 0.072 0.052 0.196 0.340 5.844 WIND MEASURED AT 10.0 METERS.

WIND SPEED CORRECTED TO THE RELEASE HEIGHT OF 10.0 METERS.

OVERALL WIND DIRECTION FREQUENCY WIND DIRECTION: N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW FREQUENCY: 6.4 6.2 5.9 4.0 3.2 3.3 9.6 6.6 5.8 5.8 6.1 6.0 5.9 6.4 10.9 7.9 OVERALL WIND SPEED FREQUENCY AS MEASURED ON THE TOWER:

MAX.WIND SPEED (M/S): 0.500 1.050 1.550 2.050 3.050 4.050 5.050 6.050 8.050 10.000 15.000 WIND SPEED FREQUENCY: 0.07 2.33 6.09 9.87 26.22 20.16 14.32 9.56 8.83 2.06 0.49 BUILDING AND RELEASE CHARACTERISTICS:

RELEASE HEIGHT: 10.00 METERS MIXING VOLUME COEFFICIENT: 0.50 BUILDING CROSS-SECTIONAL AREA: 2399.00 SQUARE METERS BOUNDARY DISTANCES (METERS) FROM THE SOURCE FOR EACH DOWNWIND SECTOR:

DOWNWIND SECTOR S SSW SW WSW W WNW NW NNW N NNE NE ENE E ESE SE SSE BOUNDARY 1 695. 695. 695. 695. 695. 695. 695. 695. 695. 695. 695. 695. 695. 695. 695. 695.

BOUNDARY 2 790. 790. 790. 790. 790. 790. 790. 790. 790. 790. 790. 790. 790. 790. 790. 790.

LR-N23-0050 LAR S23-04 LAR H23-02 USNRC COMPUTER CODE-PAVAN, VERSION 2.0 RUN DATE: 03-03-2023 PLANT NAME: SGS EAB METEOROLOGICAL INSTRUMENTATION DATA PERIOD: 2019-2021 WIND SENSORS HEIGHT: 10 m TYPE OF RELEASE: Ground Level DELTA-T HEIGHTS: 10 m - 46 m SOURCE OF DATA: A-5-ZZ-MDC-2391 COMMENTS: 695 m and 790 m EAB PROGRAM: PAVAN, 10/76, 8/79 REVISION, IMPLEMENTATION OF REGULATORY GUIDE 1.145 WINDSPEEDS ADJUSTED TO 10.0 METERS.

PERCENT OF THE TIME A GIVEN WINDSPEED IS LOWER:

WINDSPEED CUMULATIVE FREQUENCY (METER/SEC) (PERCENT) 0.50 0.07 1.05 2.40 1.55 8.49 2.05 18.36 3.05 44.58 4.05 64.75 5.05 79.06 6.05 88.62 8.05 97.45 10.00 99.51 15.00 100.00 LOG-NORMAL INTERPOLATION PERCENTILES WINDSPEED CUMULATIVE FREQUENCY (METER/SEC) (PERCENT) 0.85 1.00 1.12 3.00 1.30 5.00 1.64 10.00 1.89 15.00 2.11 20.00 2.31 25.00 2.49 30.00

LR-N23-0050 LAR S23-04 LAR H23-02 2.68 35.00 2.87 40.00 3.07 45.00 3.29 50.00 3.52 55.00 3.78 60.00 4.07 65.00 4.37 70.00 4.72 75.00 5.13 80.00 5.71 85.00 6.23 90.00

LR-N23-0050 LAR S23-04 LAR H23-02 USNRC COMPUTER CODE-PAVAN, VERSION 2.0 RUN DATE: 03-03-2023 PLANT NAME: SGS EAB METEOROLOGICAL INSTRUMENTATION DATA PERIOD: 2019-2021 WIND SENSORS HEIGHT: 10 m TYPE OF RELEASE: Ground Level DELTA-T HEIGHTS: 10 m - 46 m SOURCE OF DATA: A-5-ZZ-MDC-2391 COMMENTS: 695 m and 790 m EAB PROGRAM: PAVAN, 10/76, 8/79 REVISION, IMPLEMENTATION OF REGULATORY GUIDE 1.145 SITE EXCLUSION BOUNDARY CALCULATIONS:

S SECTOR BOUNDARY DISTANCE = 695.0 METERS LATERAL PLUME MEANDER/BUILDING WAKE CREDIT ALLOWED AS A FUNCTION OF DOWNWIND DISTANCE.

MEANDER CREDIT IS FOR WINDSPEEDS LESS THAN 6 MPS.

BUILDING WAKE CREDIT ALLOWED: C= 0.5 A= 2399. D= 58.3 BELOW ARE PRINTED THE ORDERED VALUES OF CHI/Q AND THE FREQUENCY WITH WHICH THAT VALUE IS REACHED OR EXCEEDED.

THE TOP NUMBER IS THE CHI/Q. THE MIDDLE NUMBER IS THE FREQUENCY NORMALIZED TO THIS SECTOR.

THE THIRD NUMBER IS THE FREQUENCY WITH RESPECT TO ALL TIME.

4.082E-04 2.797E-04 2.765E-04 2.698E-04 2.177E-04 2.116E-04 1.828E-04 1.697E-04 1.585E-04 1.575E-04 0.125 3.757 4.446 5.072 6.011 9.267 10.958 11.522 12.837 22.041 0.00801 0.24015 0.28418 0.32421 0.38425 0.59238 0.70045 0.73647 0.82053 1.40890 1.426E-04 1.417E-04 1.186E-04 1.174E-04 1.074E-04 9.511E-05 8.323E-05 8.323E-05 7.951E-05 7.939E-05 24.233 24.296 28.366 28.867 31.622 32.624 41.578 45.585 46.399 47.714 1.54899 1.55299 1.81316 1.84518 2.02129 2.08533 2.65770 2.91386 2.96590 3.04995 7.711E-05 6.184E-05 6.107E-05 5.967E-05 5.462E-05 5.274E-05 5.162E-05 4.697E-05 4.130E-05 3.880E-05 54.978 60.927 62.993 63.118 63.306 68.629 70.131 75.141 75.266 75.955 3.51425 3.89449 4.02658 4.03458 4.04659 4.38681 4.48287 4.80307 4.81108 4.85511 3.767E-05 3.144E-05 3.123E-05 2.776E-05 2.363E-05 2.090E-05 1.902E-05 1.676E-05 1.399E-05 1.329E-05 79.900 82.592 82.718 83.719 85.348 85.911 86.036 87.101 87.289 87.915 5.10727 5.27938 5.28738 5.35142 5.45549 5.49151 5.49952 5.56756 5.57957 5.61960 1.052E-05 1.001E-05 8.466E-06 8.025E-06 6.698E-06 6.656E-06 5.034E-06 5.033E-06 4.052E-06 3.383E-06 88.228 88.478 88.541 89.292 89.543 89.793 90.044 90.357 90.420 91.797 5.63961 5.65562 5.65962 5.70765 5.72366 5.73967 5.75568 5.77570 5.77970 5.86776

LR-N23-0050 LAR S23-04 LAR H23-02 2.548E-06 2.043E-06 1.705E-06 1.282E-06 1.032E-06 93.550 95.993 97.558 99.624 100.000 5.97983 6.13593 6.23599 6.36808 6.39209 X/Q PERCENTILES (BASED ON THE UPPER ENVELOPE OF THE ORDERED X/Q-FREQUENCY VALUES, AND AS PLOTTED ON A LOG-NORMAL GRAPH.)

PERCENT OF TIME CHI/Q IS EQUALED OR EXCEEDED CHI/Q WITH RESPECT TO WHEN THE WIND BLOWS SEC/CUBIC METER THE TOTAL TIME INTO THIS SECTOR ONLY HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 4)=

1.407 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 5)=

2.911 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 7)=

4.799 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 8)=

5.104 K I XQSAVE(K,I) XQINT(K,I) XQSLOP(K,I) 1 1 -7.80382 -9.26080 -0.38596 1 2 -8.19329 -9.75896 -0.56607 1 3 -8.21777 -10.99743 -1.02095 1 4 -8.75619 -13.40375 -2.11710 1 5 -9.39390 -11.12390 -0.91340 1 6 -9.47021 -15.62358 -3.39876 1 7 -9.96594 -22.32392 -7.42390 1 8 -10.18661 NUMXQ(K)= 8 3.296E-04 0.064 1.000 2.903E-04 0.192 3.000 2.705E-04 0.320 5.000 2.128E-04 0.639 10.000 1.830E-04 0.959 15.000 1.637E-04 1.278 20.000 1.417E-04 1.598 25.000 1.212E-04 1.918 30.000 1.058E-04 2.237 35.000

LR-N23-0050 LAR S23-04 LAR H23-02 9.385E-05 2.557 40.000 8.423E-05 2.876 45.000 8.018E-05 3.196 50.000 7.707E-05 3.516 55.000 6.732E-05 3.835 60.000 5.934E-05 4.155 65.000 5.270E-05 4.474 70.000 4.712E-05 4.794 75.000 2.324E-04 0.5 7.82 ANNUAL AVERAGE = 2.83E-06 K= 1 FIVEXQ(K)= 2.324E-04 FIVEPR(K)= 7.822

LR-N23-0050 LAR S23-04 LAR H23-02 USNRC COMPUTER CODE-PAVAN, VERSION 2.0 RUN DATE: 03-03-2023 PLANT NAME: SGS EAB METEOROLOGICAL INSTRUMENTATION DATA PERIOD: 2019-2021 WIND SENSORS HEIGHT: 10 m TYPE OF RELEASE: Ground Level DELTA-T HEIGHTS: 10 m - 46 m SOURCE OF DATA: A-5-ZZ-MDC-2391 COMMENTS: 695 m and 790 m EAB PROGRAM: PAVAN, 10/76, 8/79 REVISION, IMPLEMENTATION OF REGULATORY GUIDE 1.145 SITE EXCLUSION BOUNDARY CALCULATIONS:

SSW SECTOR BOUNDARY DISTANCE = 695.0 METERS LATERAL PLUME MEANDER/BUILDING WAKE CREDIT ALLOWED AS A FUNCTION OF DOWNWIND DISTANCE.

MEANDER CREDIT IS FOR WINDSPEEDS LESS THAN 6 MPS.

BUILDING WAKE CREDIT ALLOWED: C= 0.5 A= 2399. D= 58.3 BELOW ARE PRINTED THE ORDERED VALUES OF CHI/Q AND THE FREQUENCY WITH WHICH THAT VALUE IS REACHED OR EXCEEDED.

THE TOP NUMBER IS THE CHI/Q. THE MIDDLE NUMBER IS THE FREQUENCY NORMALIZED TO THIS SECTOR.

THE THIRD NUMBER IS THE FREQUENCY WITH RESPECT TO ALL TIME.

4.082E-04 2.797E-04 2.765E-04 2.698E-04 2.465E-04 2.177E-04 2.116E-04 1.828E-04 1.697E-04 1.693E-04 0.260 4.096 5.462 6.437 6.502 8.257 10.338 11.834 12.094 12.159 0.01601 0.25216 0.33622 0.39625 0.40026 0.50833 0.63641 0.72847 0.74448 0.74848 1.585E-04 1.575E-04 1.426E-04 1.417E-04 1.186E-04 1.174E-04 1.074E-04 9.511E-05 8.323E-05 8.323E-05 13.069 20.481 22.692 22.757 25.813 26.463 29.194 29.779 40.312 43.888 0.80451 1.26081 1.39689 1.40090 1.58902 1.62904 1.79715 1.83317 2.48159 2.70173 8.063E-05 7.951E-05 7.939E-05 7.711E-05 6.184E-05 6.107E-05 5.967E-05 5.462E-05 5.274E-05 5.162E-05 43.953 45.059 45.124 51.886 54.811 57.087 57.152 57.217 63.979 65.020 2.70573 2.77378 2.77778 3.19404 3.37416 3.51425 3.51825 3.52225 3.93852 4.00256 4.697E-05 4.130E-05 3.880E-05 3.767E-05 3.144E-05 3.123E-05 2.776E-05 2.614E-05 2.363E-05 2.090E-05 71.066 71.261 71.847 76.918 81.014 81.079 81.664 81.795 83.615 84.330 4.37480 4.38681 4.42283 4.73503 4.98719 4.99119 5.02722 5.03522 5.14729 5.19132 1.902E-05 1.676E-05 1.399E-05 1.329E-05 1.052E-05 1.001E-05 9.826E-06 8.025E-06 6.698E-06 6.656E-06 84.395 85.436 86.411 86.931 87.321 87.971 88.101 89.077 89.792 90.052 5.19532 5.25937 5.31940 5.35142 5.37544 5.41547 5.42347 5.48351 5.52754 5.54355

LR-N23-0050 LAR S23-04 LAR H23-02 5.034E-06 5.033E-06 3.383E-06 2.548E-06 2.043E-06 1.705E-06 1.282E-06 1.032E-06 90.572 91.027 92.588 95.124 97.334 98.830 99.935 100.000 5.57557 5.60359 5.69965 5.85575 5.99183 6.08389 6.15194 6.15594 X/Q PERCENTILES (BASED ON THE UPPER ENVELOPE OF THE ORDERED X/Q-FREQUENCY VALUES, AND AS PLOTTED ON A LOG-NORMAL GRAPH.)

PERCENT OF TIME CHI/Q IS EQUALED OR EXCEEDED CHI/Q WITH RESPECT TO WHEN THE WIND BLOWS SEC/CUBIC METER THE TOTAL TIME INTO THIS SECTOR ONLY HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 4)=

1.259 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 5)=

2.699 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 6)=

3.191 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 7)=

4.371 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 8)=

4.731 K I XQSAVE(K,I) XQINT(K,I) XQSLOP(K,I) 2 1 -7.80382 -9.38219 -0.43861 2 2 -8.19329 -9.40110 -0.44559 2 3 -8.21777 -11.64571 -1.29082 2 4 -8.75619 -13.33841 -2.04699 2 5 -9.39390 -11.39306 -1.03746 2 6 -9.47021 -15.83796 -3.43567 2 7 -9.96594 -19.98021 -5.85926 2 8 -10.18661 NUMXQ(K)= 8 3.475E-04 0.062 1.000 3.009E-04 0.185 3.000 2.801E-04 0.308 5.000 2.217E-04 0.616 10.000 1.834E-04 0.923 15.000 1.594E-04 1.231 20.000 1.342E-04 1.539 25.000

LR-N23-0050 LAR S23-04 LAR H23-02 1.155E-04 1.847 30.000 1.014E-04 2.155 35.000 9.031E-05 2.462 40.000 8.230E-05 2.770 45.000 7.844E-05 3.078 50.000 7.050E-05 3.386 55.000 6.155E-05 3.694 60.000 5.422E-05 4.001 65.000 4.814E-05 4.309 70.000 4.044E-05 4.617 75.000 2.435E-04 0.5 8.12 ANNUAL AVERAGE = 2.83E-06 K= 2 FIVEXQ(K)= 2.435E-04 FIVEPR(K)= 8.122

LR-N23-0050 LAR S23-04 LAR H23-02 USNRC COMPUTER CODE-PAVAN, VERSION 2.0 RUN DATE: 03-03-2023 PLANT NAME: SGS EAB METEOROLOGICAL INSTRUMENTATION DATA PERIOD: 2019-2021 WIND SENSORS HEIGHT: 10 m TYPE OF RELEASE: Ground Level DELTA-T HEIGHTS: 10 m - 46 m SOURCE OF DATA: A-5-ZZ-MDC-2391 COMMENTS: 695 m and 790 m EAB PROGRAM: PAVAN, 10/76, 8/79 REVISION, IMPLEMENTATION OF REGULATORY GUIDE 1.145 SITE EXCLUSION BOUNDARY CALCULATIONS:

SW SECTOR BOUNDARY DISTANCE = 695.0 METERS LATERAL PLUME MEANDER/BUILDING WAKE CREDIT ALLOWED AS A FUNCTION OF DOWNWIND DISTANCE.

MEANDER CREDIT IS FOR WINDSPEEDS LESS THAN 6 MPS.

BUILDING WAKE CREDIT ALLOWED: C= 0.5 A= 2399. D= 58.3 BELOW ARE PRINTED THE ORDERED VALUES OF CHI/Q AND THE FREQUENCY WITH WHICH THAT VALUE IS REACHED OR EXCEEDED.

THE TOP NUMBER IS THE CHI/Q. THE MIDDLE NUMBER IS THE FREQUENCY NORMALIZED TO THIS SECTOR.

THE THIRD NUMBER IS THE FREQUENCY WITH RESPECT TO ALL TIME.

4.082E-04 2.797E-04 2.765E-04 2.698E-04 2.465E-04 2.177E-04 2.116E-04 1.828E-04 1.697E-04 1.585E-04 0.751 4.027 5.188 6.143 6.212 7.509 8.191 10.239 10.375 11.809 0.04403 0.23615 0.30419 0.36023 0.36423 0.44028 0.48031 0.60038 0.60839 0.69244 1.575E-04 1.426E-04 1.186E-04 1.174E-04 1.074E-04 9.511E-05 8.323E-05 8.323E-05 8.063E-05 7.951E-05 17.270 20.819 22.526 22.799 25.529 25.597 35.563 41.229 41.297 43.823 1.01265 1.22078 1.32085 1.33686 1.49696 1.50096 2.08533 2.41755 2.42155 2.56964 7.711E-05 6.184E-05 6.107E-05 5.462E-05 5.274E-05 5.162E-05 4.803E-05 4.697E-05 4.130E-05 3.880E-05 48.532 51.058 54.676 54.949 65.392 66.485 66.553 72.764 72.969 73.038 2.84582 2.99392 3.20605 3.22206 3.83445 3.89849 3.90250 4.26673 4.27874 4.28274 3.767E-05 3.144E-05 2.776E-05 2.614E-05 2.363E-05 2.090E-05 1.977E-05 1.902E-05 1.676E-05 1.399E-05 77.406 79.317 80.751 81.024 82.116 83.140 83.345 83.481 84.232 84.369 4.53890 4.65098 4.73503 4.75104 4.81508 4.87512 4.88713 4.89513 4.93916 4.94717 1.329E-05 1.052E-05 1.001E-05 8.025E-06 6.698E-06 6.656E-06 5.034E-06 5.033E-06 3.383E-06 2.548E-06 85.119 85.256 85.734 86.075 86.485 86.962 87.235 88.532 91.945 96.997 4.99119 4.99920 5.02722 5.04723 5.07125 5.09926 5.11527 5.19132 5.39145 5.68764

LR-N23-0050 LAR S23-04 LAR H23-02 2.043E-06 1.705E-06 1.282E-06 98.567 99.590 100.000 5.77970 5.83974 5.86375 X/Q PERCENTILES (BASED ON THE UPPER ENVELOPE OF THE ORDERED X/Q-FREQUENCY VALUES, AND AS PLOTTED ON A LOG-NORMAL GRAPH.)

PERCENT OF TIME CHI/Q IS EQUALED OR EXCEEDED CHI/Q WITH RESPECT TO WHEN THE WIND BLOWS SEC/CUBIC METER THE TOTAL TIME INTO THIS SECTOR ONLY HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 3)=

1.219 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 4)=

2.843 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 5)=

4.263 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 6)=

4.535 K I XQSAVE(K,I) XQINT(K,I) XQSLOP(K,I) 3 1 -7.80382 -9.95951 -0.64806 3 2 -8.21777 -12.14414 -1.46091 3 3 -8.85568 -12.84680 -1.77307 3 4 -9.47021 -14.61618 -2.70218 3 5 -9.96594 -22.95362 -7.54694 3 6 -10.18661 NUMXQ(K)= 6 3.874E-04 0.059 1.000 3.134E-04 0.176 3.000 2.820E-04 0.293 5.000 2.114E-04 0.586 10.000 1.708E-04 0.880 15.000 1.458E-04 1.173 20.000 1.256E-04 1.466 25.000 1.104E-04 1.759 30.000 9.869E-05 2.052 35.000 8.937E-05 2.346 40.000 8.174E-05 2.639 45.000

LR-N23-0050 LAR S23-04 LAR H23-02 7.444E-05 2.932 50.000 6.642E-05 3.225 55.000 5.975E-05 3.518 60.000 5.413E-05 3.811 65.000 4.933E-05 4.105 70.000 4.218E-05 4.398 75.000 2.293E-04 0.5 8.53 ANNUAL AVERAGE = 2.80E-06 K= 3 FIVEXQ(K)= 2.293E-04 FIVEPR(K)= 8.527

LR-N23-0050 LAR S23-04 LAR H23-02 USNRC COMPUTER CODE-PAVAN, VERSION 2.0 RUN DATE: 03-03-2023 PLANT NAME: SGS EAB METEOROLOGICAL INSTRUMENTATION DATA PERIOD: 2019-2021 WIND SENSORS HEIGHT: 10 m TYPE OF RELEASE: Ground Level DELTA-T HEIGHTS: 10 m - 46 m SOURCE OF DATA: A-5-ZZ-MDC-2391 COMMENTS: 695 m and 790 m EAB PROGRAM: PAVAN, 10/76, 8/79 REVISION, IMPLEMENTATION OF REGULATORY GUIDE 1.145 SITE EXCLUSION BOUNDARY CALCULATIONS:

WSW SECTOR BOUNDARY DISTANCE = 695.0 METERS LATERAL PLUME MEANDER/BUILDING WAKE CREDIT ALLOWED AS A FUNCTION OF DOWNWIND DISTANCE.

MEANDER CREDIT IS FOR WINDSPEEDS LESS THAN 6 MPS.

BUILDING WAKE CREDIT ALLOWED: C= 0.5 A= 2399. D= 58.3 BELOW ARE PRINTED THE ORDERED VALUES OF CHI/Q AND THE FREQUENCY WITH WHICH THAT VALUE IS REACHED OR EXCEEDED.

THE TOP NUMBER IS THE CHI/Q. THE MIDDLE NUMBER IS THE FREQUENCY NORMALIZED TO THIS SECTOR.

THE THIRD NUMBER IS THE FREQUENCY WITH RESPECT TO ALL TIME.

5.666E-04 4.082E-04 2.797E-04 2.765E-04 2.698E-04 2.177E-04 2.116E-04 1.828E-04 1.585E-04 1.575E-04 0.199 1.393 3.184 6.269 7.463 9.353 9.652 14.229 16.915 20.995 0.00801 0.05604 0.12808 0.25216 0.30019 0.37624 0.38825 0.57237 0.68044 0.84454 1.426E-04 1.186E-04 1.174E-04 1.074E-04 9.511E-05 8.323E-05 8.323E-05 7.951E-05 7.711E-05 6.184E-05 24.279 24.677 25.572 30.050 30.249 40.100 47.761 50.547 53.731 54.826 0.97663 0.99264 1.02866 1.20877 1.21678 1.61303 1.92123 2.03330 2.16138 2.20541 6.107E-05 5.462E-05 5.274E-05 5.162E-05 4.697E-05 4.130E-05 3.880E-05 3.859E-05 3.767E-05 3.144E-05 59.502 59.602 67.264 67.861 71.841 72.537 72.637 72.736 75.224 76.119 2.39353 2.39753 2.70573 2.72975 2.88985 2.91787 2.92187 2.92587 3.02594 3.06196 2.776E-05 2.614E-05 2.363E-05 2.090E-05 1.977E-05 1.676E-05 1.399E-05 1.329E-05 1.052E-05 1.001E-05 78.109 78.507 78.706 80.100 80.398 80.498 80.697 81.891 81.990 82.786 3.14201 3.15802 3.16603 3.22206 3.23407 3.23807 3.24608 3.29411 3.29811 3.33013 9.826E-06 8.025E-06 6.698E-06 6.656E-06 5.034E-06 5.033E-06 3.383E-06 2.548E-06 2.043E-06 1.705E-06 82.985 83.582 83.682 84.776 85.174 86.766 91.144 94.826 97.313 98.507 3.33814 3.36215 3.36615 3.41018 3.42619 3.49023 3.66635 3.81444 3.91451 3.96254

LR-N23-0050 LAR S23-04 LAR H23-02 1.282E-06 100.000 4.02258 X/Q PERCENTILES (BASED ON THE UPPER ENVELOPE OF THE ORDERED X/Q-FREQUENCY VALUES, AND AS PLOTTED ON A LOG-NORMAL GRAPH.)

PERCENT OF TIME CHI/Q IS EQUALED OR EXCEEDED CHI/Q WITH RESPECT TO WHEN THE WIND BLOWS SEC/CUBIC METER THE TOTAL TIME INTO THIS SECTOR ONLY HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 4)=

0.844 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 5)=

0.975 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 6)=

2.159 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 7)=

2.703 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 8)=

2.887 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 9)=

3.023 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE(10)=

3.139 K I XQSAVE(K,I) XQINT(K,I) XQSLOP(K,I) 4 1 -7.47583 -9.87360 -0.63518 4 2 -7.80382 -10.44544 -0.81067 4 3 -8.21777 -12.34558 -1.50215 4 4 -8.75619 -13.16984 -1.84709 4 5 -8.85568 -13.43108 -1.95894 4 6 -9.47021 -17.50727 -3.97492 4 7 -9.85020 -17.62192 -4.03444 4 8 -9.96594 -30.65274 -10.90124 4 9 -10.18661 -44.56358 -18.31081 4 10 -10.49200 NUMXQ(K)= 10 4.330E-04 0.040 1.000

LR-N23-0050 LAR S23-04 LAR H23-02 3.403E-04 0.121 3.000 2.995E-04 0.201 5.000 2.331E-04 0.402 10.000 1.889E-04 0.603 15.000 1.617E-04 0.805 20.000 1.395E-04 1.006 25.000 1.218E-04 1.207 30.000 1.083E-04 1.408 35.000 9.768E-05 1.609 40.000 8.899E-05 1.810 45.000 8.177E-05 2.011 50.000 7.418E-05 2.212 55.000 6.409E-05 2.414 60.000 5.593E-05 2.615 65.000 4.917E-05 2.816 70.000 3.822E-05 3.017 75.000 2.085E-04 0.5 12.43 ANNUAL AVERAGE = 2.33E-06 K= 4 FIVEXQ(K)= 2.085E-04 FIVEPR(K)=12.430

LR-N23-0050 LAR S23-04 LAR H23-02 USNRC COMPUTER CODE-PAVAN, VERSION 2.0 RUN DATE: 03-03-2023 PLANT NAME: SGS EAB METEOROLOGICAL INSTRUMENTATION DATA PERIOD: 2019-2021 WIND SENSORS HEIGHT: 10 m TYPE OF RELEASE: Ground Level DELTA-T HEIGHTS: 10 m - 46 m SOURCE OF DATA: A-5-ZZ-MDC-2391 COMMENTS: 695 m and 790 m EAB PROGRAM: PAVAN, 10/76, 8/79 REVISION, IMPLEMENTATION OF REGULATORY GUIDE 1.145 SITE EXCLUSION BOUNDARY CALCULATIONS:

W SECTOR BOUNDARY DISTANCE = 695.0 METERS LATERAL PLUME MEANDER/BUILDING WAKE CREDIT ALLOWED AS A FUNCTION OF DOWNWIND DISTANCE.

MEANDER CREDIT IS FOR WINDSPEEDS LESS THAN 6 MPS.

BUILDING WAKE CREDIT ALLOWED: C= 0.5 A= 2399. D= 58.3 BELOW ARE PRINTED THE ORDERED VALUES OF CHI/Q AND THE FREQUENCY WITH WHICH THAT VALUE IS REACHED OR EXCEEDED.

THE TOP NUMBER IS THE CHI/Q. THE MIDDLE NUMBER IS THE FREQUENCY NORMALIZED TO THIS SECTOR.

THE THIRD NUMBER IS THE FREQUENCY WITH RESPECT TO ALL TIME.

5.666E-04 4.082E-04 2.797E-04 2.765E-04 2.698E-04 2.465E-04 2.177E-04 1.828E-04 1.585E-04 1.575E-04 0.124 0.989 3.461 7.664 9.271 9.394 12.237 16.811 18.912 22.868 0.00400 0.03202 0.11207 0.24816 0.30019 0.30419 0.39625 0.54435 0.61239 0.74047 1.426E-04 1.186E-04 1.174E-04 1.074E-04 8.323E-05 8.323E-05 7.951E-05 7.711E-05 6.184E-05 6.107E-05 28.430 28.801 29.666 35.970 48.208 57.602 60.321 63.906 64.400 68.356 0.92059 0.93260 0.96061 1.16475 1.56100 1.86519 1.95325 2.06932 2.08533 2.21342 5.462E-05 5.274E-05 5.162E-05 4.697E-05 4.130E-05 3.767E-05 3.144E-05 2.776E-05 2.614E-05 2.363E-05 68.974 75.278 75.525 79.110 79.728 81.459 81.706 82.818 83.189 83.560 2.23343 2.43756 2.44556 2.56164 2.58165 2.63769 2.64569 2.68172 2.69372 2.70573 2.090E-05 1.977E-05 1.676E-05 1.329E-05 1.268E-05 1.001E-05 9.826E-06 6.656E-06 5.033E-06 3.383E-06 84.549 84.920 85.167 86.156 86.279 86.650 86.774 87.145 88.504 93.078 2.73775 2.74976 2.75776 2.78978 2.79379 2.80580 2.80980 2.82181 2.86583 3.01393 2.548E-06 2.043E-06 1.705E-06 1.282E-06 96.415 98.640 99.506 100.000 3.12200 3.19404 3.22206 3.23807

LR-N23-0050 LAR S23-04 LAR H23-02 X/Q PERCENTILES (BASED ON THE UPPER ENVELOPE OF THE ORDERED X/Q-FREQUENCY VALUES, AND AS PLOTTED ON A LOG-NORMAL GRAPH.)

PERCENT OF TIME CHI/Q IS EQUALED OR EXCEEDED CHI/Q WITH RESPECT TO WHEN THE WIND BLOWS SEC/CUBIC METER THE TOTAL TIME INTO THIS SECTOR ONLY HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 4)=

0.920 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 5)=

2.067 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 6)=

2.559 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 7)=

2.635 K I XQSAVE(K,I) XQINT(K,I) XQSLOP(K,I) 5 1 -7.47583 -9.91586 -0.61862 5 2 -7.80382 -9.92535 -0.62140 5 3 -8.21777 -12.70930 -1.63450 5 4 -8.85568 -13.41772 -1.93498 5 5 -9.47021 -20.69200 -5.50067 5 6 -9.96594 -44.12946 -17.52016 5 7 -10.18661 NUMXQ(K)= 7 4.074E-04 0.032 1.000 3.356E-04 0.097 3.000 3.049E-04 0.162 5.000 2.590E-04 0.324 10.000 2.071E-04 0.486 15.000 1.757E-04 0.648 20.000 1.540E-04 0.810 25.000 1.372E-04 0.971 30.000 1.225E-04 1.133 35.000 1.110E-04 1.295 40.000 1.015E-04 1.457 45.000 9.359E-05 1.619 50.000 8.688E-05 1.781 55.000 8.110E-05 1.943 60.000

LR-N23-0050 LAR S23-04 LAR H23-02 7.418E-05 2.105 65.000 6.254E-05 2.267 70.000 5.325E-05 2.429 75.000 4.318E-05 2.590 80.000 2.038E-04 0.5 15.44 ANNUAL AVERAGE = 2.08E-06 K= 5 FIVEXQ(K)= 2.038E-04 FIVEPR(K)=15.441

LR-N23-0050 LAR S23-04 LAR H23-02 USNRC COMPUTER CODE-PAVAN, VERSION 2.0 RUN DATE: 03-03-2023 PLANT NAME: SGS EAB METEOROLOGICAL INSTRUMENTATION DATA PERIOD: 2019-2021 WIND SENSORS HEIGHT: 10 m TYPE OF RELEASE: Ground Level DELTA-T HEIGHTS: 10 m - 46 m SOURCE OF DATA: A-5-ZZ-MDC-2391 COMMENTS: 695 m and 790 m EAB PROGRAM: PAVAN, 10/76, 8/79 REVISION, IMPLEMENTATION OF REGULATORY GUIDE 1.145 SITE EXCLUSION BOUNDARY CALCULATIONS:

WNW SECTOR BOUNDARY DISTANCE = 695.0 METERS LATERAL PLUME MEANDER/BUILDING WAKE CREDIT ALLOWED AS A FUNCTION OF DOWNWIND DISTANCE.

MEANDER CREDIT IS FOR WINDSPEEDS LESS THAN 6 MPS.

BUILDING WAKE CREDIT ALLOWED: C= 0.5 A= 2399. D= 58.3 BELOW ARE PRINTED THE ORDERED VALUES OF CHI/Q AND THE FREQUENCY WITH WHICH THAT VALUE IS REACHED OR EXCEEDED.

THE TOP NUMBER IS THE CHI/Q. THE MIDDLE NUMBER IS THE FREQUENCY NORMALIZED TO THIS SECTOR.

THE THIRD NUMBER IS THE FREQUENCY WITH RESPECT TO ALL TIME.

4.082E-04 2.797E-04 2.765E-04 2.698E-04 2.177E-04 2.116E-04 1.828E-04 1.585E-04 1.575E-04 1.426E-04 0.613 6.863 8.701 9.926 12.745 13.113 14.706 15.931 26.593 29.657 0.02001 0.22414 0.28418 0.32421 0.41627 0.42827 0.48031 0.52033 0.86856 0.96862 1.186E-04 1.174E-04 1.074E-04 9.511E-05 8.323E-05 8.323E-05 7.951E-05 7.711E-05 6.184E-05 6.107E-05 31.863 32.598 36.275 36.397 49.020 54.412 55.515 65.686 68.137 70.956 1.04067 1.06468 1.18476 1.18876 1.60102 1.77714 1.81316 2.14537 2.22542 2.31748 5.274E-05 5.162E-05 4.697E-05 4.130E-05 3.859E-05 3.767E-05 3.144E-05 2.776E-05 2.363E-05 2.090E-05 76.471 77.206 80.760 81.127 81.373 83.824 84.191 85.172 85.662 86.520 2.49760 2.52161 2.63769 2.64970 2.65770 2.73775 2.74976 2.78178 2.79779 2.82581 1.977E-05 1.902E-05 1.676E-05 1.399E-05 1.329E-05 1.052E-05 1.001E-05 9.826E-06 8.025E-06 6.698E-06 86.642 87.010 87.745 87.868 88.113 88.358 89.338 89.583 90.074 90.319 2.82981 2.84182 2.86583 2.86984 2.87784 2.88585 2.91787 2.92587 2.94188 2.94989 6.656E-06 5.034E-06 5.033E-06 3.383E-06 2.548E-06 2.043E-06 1.705E-06 1.282E-06 90.686 91.176 91.789 94.118 95.833 97.549 98.652 100.000 2.96189 2.97790 2.99792 3.07397 3.13000 3.18604 3.22206 3.26609

LR-N23-0050 LAR S23-04 LAR H23-02 X/Q PERCENTILES (BASED ON THE UPPER ENVELOPE OF THE ORDERED X/Q-FREQUENCY VALUES, AND AS PLOTTED ON A LOG-NORMAL GRAPH.)

PERCENT OF TIME CHI/Q IS EQUALED OR EXCEEDED CHI/Q WITH RESPECT TO WHEN THE WIND BLOWS SEC/CUBIC METER THE TOTAL TIME INTO THIS SECTOR ONLY HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 4)=

0.868 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 5)=

2.143 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 6)=

2.635 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 7)=

2.735 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 8)=

2.863 K I XQSAVE(K,I) XQINT(K,I) XQSLOP(K,I) 6 1 -7.80382 -9.58465 -0.50305 6 2 -8.19329 -9.75895 -0.56607 6 3 -8.21777 -12.48630 -1.56780 6 4 -8.75619 -13.55309 -2.01619 6 5 -9.47021 -20.91842 -5.65331 6 6 -9.96594 -36.48948 -13.69056 6 7 -10.18661 -88.23505 -40.62398 6 8 -10.99625 NUMXQ(K)= 8 3.821E-04 0.033 1.000 3.266E-04 0.098 3.000 3.021E-04 0.163 5.000 2.688E-04 0.327 10.000 2.169E-04 0.490 15.000 1.852E-04 0.653 20.000 1.632E-04 0.817 25.000 1.439E-04 0.980 30.000 1.279E-04 1.143 35.000 1.153E-04 1.306 40.000 1.051E-04 1.470 45.000

LR-N23-0050 LAR S23-04 LAR H23-02 9.658E-05 1.633 50.000 8.937E-05 1.796 55.000 8.318E-05 1.960 60.000 7.780E-05 2.123 65.000 6.631E-05 2.286 70.000 5.620E-05 2.450 75.000 4.807E-05 2.613 80.000 2.945E-05 2.776 85.000 2.145E-04 0.5 15.31 ANNUAL AVERAGE = 1.79E-06 K= 6 FIVEXQ(K)= 2.145E-04 FIVEPR(K)=15.309

LR-N23-0050 LAR S23-04 LAR H23-02 USNRC COMPUTER CODE-PAVAN, VERSION 2.0 RUN DATE: 03-03-2023 PLANT NAME: SGS EAB METEOROLOGICAL INSTRUMENTATION DATA PERIOD: 2019-2021 WIND SENSORS HEIGHT: 10 m TYPE OF RELEASE: Ground Level DELTA-T HEIGHTS: 10 m - 46 m SOURCE OF DATA: A-5-ZZ-MDC-2391 COMMENTS: 695 m and 790 m EAB PROGRAM: PAVAN, 10/76, 8/79 REVISION, IMPLEMENTATION OF REGULATORY GUIDE 1.145 SITE EXCLUSION BOUNDARY CALCULATIONS:

NW SECTOR BOUNDARY DISTANCE = 695.0 METERS LATERAL PLUME MEANDER/BUILDING WAKE CREDIT ALLOWED AS A FUNCTION OF DOWNWIND DISTANCE.

MEANDER CREDIT IS FOR WINDSPEEDS LESS THAN 6 MPS.

BUILDING WAKE CREDIT ALLOWED: C= 0.5 A= 2399. D= 58.3 BELOW ARE PRINTED THE ORDERED VALUES OF CHI/Q AND THE FREQUENCY WITH WHICH THAT VALUE IS REACHED OR EXCEEDED.

THE TOP NUMBER IS THE CHI/Q. THE MIDDLE NUMBER IS THE FREQUENCY NORMALIZED TO THIS SECTOR.

THE THIRD NUMBER IS THE FREQUENCY WITH RESPECT TO ALL TIME.

5.666E-04 4.082E-04 2.797E-04 2.765E-04 2.698E-04 2.177E-04 2.116E-04 1.828E-04 1.697E-04 1.585E-04 0.083 0.208 2.874 3.207 3.374 4.165 6.497 7.080 8.955 9.204 0.00801 0.02001 0.27618 0.30820 0.32421 0.40026 0.62440 0.68044 0.86055 0.88457 1.575E-04 1.426E-04 1.417E-04 1.186E-04 1.174E-04 1.074E-04 1.065E-04 9.511E-05 8.571E-05 8.323E-05 12.287 13.120 14.994 18.242 18.492 19.117 20.575 22.616 22.699 28.322 1.18076 1.26081 1.44092 1.75312 1.77714 1.83718 1.97727 2.17339 2.18140 2.72174 8.323E-05 7.951E-05 7.939E-05 7.711E-05 6.184E-05 6.107E-05 5.967E-05 5.274E-05 5.162E-05 4.803E-05 29.863 30.154 31.529 38.609 45.564 46.231 47.813 50.646 54.810 55.060 2.86984 2.89785 3.02994 3.71037 4.37880 4.44284 4.59494 4.86711 5.26737 5.29139 4.697E-05 4.130E-05 3.880E-05 3.859E-05 3.767E-05 3.202E-05 3.144E-05 3.123E-05 2.776E-05 2.614E-05 58.642 58.684 61.349 61.433 65.973 66.222 70.429 70.970 71.304 71.387 5.63561 5.63961 5.89577 5.90378 6.34006 6.36407 6.76833 6.82036 6.85238 6.86039 2.363E-05 2.090E-05 2.082E-05 1.977E-05 1.902E-05 1.676E-05 1.399E-05 1.329E-05 1.268E-05 1.052E-05 76.093 76.718 76.801 76.926 77.718 78.634 79.384 79.675 80.550 81.258 7.31268 7.37272 7.38072 7.39273 7.46878 7.55684 7.62888 7.65690 7.74095 7.80900

LR-N23-0050 LAR S23-04 LAR H23-02 1.001E-05 9.826E-06 8.466E-06 8.025E-06 6.698E-06 6.656E-06 5.644E-06 5.034E-06 5.033E-06 4.052E-06 81.883 82.007 82.091 82.757 83.757 83.840 83.882 84.631 84.798 85.090 7.86903 7.88104 7.88905 7.95309 8.04915 8.05715 8.06116 8.13320 8.14921 8.17723 3.383E-06 2.702E-06 2.548E-06 2.043E-06 1.705E-06 1.282E-06 1.032E-06 6.878E-07 86.047 86.089 88.005 91.545 95.085 99.000 99.500 100.000 8.26929 8.27329 8.45741 8.79763 9.13785 9.51409 9.56212 9.61015 X/Q PERCENTILES (BASED ON THE UPPER ENVELOPE OF THE ORDERED X/Q-FREQUENCY VALUES, AND AS PLOTTED ON A LOG-NORMAL GRAPH.)

PERCENT OF TIME CHI/Q IS EQUALED OR EXCEEDED CHI/Q WITH RESPECT TO WHEN THE WIND BLOWS SEC/CUBIC METER THE TOTAL TIME INTO THIS SECTOR ONLY HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 3)=

0.624 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 4)=

1.179 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 5)=

1.439 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 6)=

2.867 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 8)=

5.264 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 9)=

5.632 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE(10)=

6.336 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE(11)=

6.817 K I XQSAVE(K,I) XQINT(K,I) XQSLOP(K,I) 7 1 -7.47583 -10.09099 -0.69277 7 2 -8.19329 -11.23485 -1.11034 7 3 -8.46070 -11.60646 -1.25907 7 4 -8.75619 -11.85323 -1.36808 7 5 -8.86204 -12.93214 -1.86155

LR-N23-0050 LAR S23-04 LAR H23-02 7 6 -9.39390 -10.65559 -0.66381 7 7 -9.47021 -13.78973 -2.41891 7 8 -9.87155 -14.45490 -2.82955 7 9 -9.96594 -15.86897 -3.72089 7 10 -10.18661 -17.81059 -4.99230 7 11 -10.37408 NUMXQ(K)= 11 3.556E-04 0.096 1.000 2.807E-04 0.288 3.000 2.343E-04 0.481 5.000 1.737E-04 0.961 10.000 1.416E-04 1.442 15.000 1.142E-04 1.922 20.000 9.600E-05 2.403 25.000 8.312E-05 2.883 30.000 7.943E-05 3.364 35.000 7.414E-05 3.844 40.000 6.492E-05 4.325 45.000 5.750E-05 4.805 50.000 5.138E-05 5.286 55.000 4.502E-05 5.766 60.000 3.875E-05 6.247 65.000 3.236E-05 6.727 70.000 2.307E-04 0.5 5.20 ANNUAL AVERAGE = 2.99E-06 K= 7 FIVEXQ(K)= 2.307E-04 FIVEPR(K)= 5.203

LR-N23-0050 LAR S23-04 LAR H23-02 USNRC COMPUTER CODE-PAVAN, VERSION 2.0 RUN DATE: 03-03-2023 PLANT NAME: SGS EAB METEOROLOGICAL INSTRUMENTATION DATA PERIOD: 2019-2021 WIND SENSORS HEIGHT: 10 m TYPE OF RELEASE: Ground Level DELTA-T HEIGHTS: 10 m - 46 m SOURCE OF DATA: A-5-ZZ-MDC-2391 COMMENTS: 695 m and 790 m EAB PROGRAM: PAVAN, 10/76, 8/79 REVISION, IMPLEMENTATION OF REGULATORY GUIDE 1.145 SITE EXCLUSION BOUNDARY CALCULATIONS:

NNW SECTOR BOUNDARY DISTANCE = 695.0 METERS LATERAL PLUME MEANDER/BUILDING WAKE CREDIT ALLOWED AS A FUNCTION OF DOWNWIND DISTANCE.

MEANDER CREDIT IS FOR WINDSPEEDS LESS THAN 6 MPS.

BUILDING WAKE CREDIT ALLOWED: C= 0.5 A= 2399. D= 58.3 BELOW ARE PRINTED THE ORDERED VALUES OF CHI/Q AND THE FREQUENCY WITH WHICH THAT VALUE IS REACHED OR EXCEEDED.

THE TOP NUMBER IS THE CHI/Q. THE MIDDLE NUMBER IS THE FREQUENCY NORMALIZED TO THIS SECTOR.

THE THIRD NUMBER IS THE FREQUENCY WITH RESPECT TO ALL TIME.

4.082E-04 2.797E-04 2.765E-04 2.698E-04 2.177E-04 2.116E-04 1.828E-04 1.697E-04 1.585E-04 1.575E-04 0.243 1.639 2.550 2.732 3.461 4.797 5.464 6.557 7.165 10.808 0.01601 0.10807 0.16811 0.18012 0.22815 0.31620 0.36023 0.43228 0.47230 0.71246 1.426E-04 1.417E-04 1.186E-04 1.174E-04 1.074E-04 1.065E-04 9.511E-05 8.323E-05 8.323E-05 7.951E-05 12.386 12.933 15.240 15.422 16.636 17.243 17.972 25.562 29.083 30.176 0.81652 0.85255 1.00464 1.01665 1.09670 1.13673 1.18476 1.68508 1.91723 1.98927 7.939E-05 7.711E-05 6.184E-05 6.107E-05 5.967E-05 5.462E-05 5.274E-05 5.162E-05 4.803E-05 4.697E-05 30.723 38.069 44.444 46.084 46.509 46.570 51.184 55.009 55.252 60.413 2.02530 2.50961 2.92987 3.03794 3.06596 3.06996 3.37416 3.62632 3.64233 3.98255 3.880E-05 3.767E-05 3.202E-05 3.144E-05 3.123E-05 2.776E-05 2.363E-05 2.090E-05 2.082E-05 1.902E-05 62.417 68.610 68.731 74.863 75.288 76.442 81.542 82.271 82.332 82.817 4.11463 4.52289 4.53090 4.93516 4.96318 5.03922 5.37544 5.42347 5.42747 5.45949 1.676E-05 1.399E-05 1.329E-05 1.268E-05 1.052E-05 1.001E-05 9.826E-06 8.025E-06 6.698E-06 6.656E-06 83.667 84.092 85.064 85.185 85.732 86.339 86.460 86.764 87.189 87.492 5.51553 5.54355 5.60759 5.61559 5.65162 5.69164 5.69965 5.71966 5.74768 5.76769

LR-N23-0050 LAR S23-04 LAR H23-02 5.644E-06 5.034E-06 5.033E-06 3.383E-06 2.548E-06 2.043E-06 1.705E-06 1.282E-06 1.032E-06 6.878E-07 87.675 87.978 88.525 89.800 91.803 94.414 96.721 99.454 99.879 100.000 5.77970 5.79971 5.83573 5.91979 6.05187 6.22398 6.37608 6.55620 6.58421 6.59222 X/Q PERCENTILES (BASED ON THE UPPER ENVELOPE OF THE ORDERED X/Q-FREQUENCY VALUES, AND AS PLOTTED ON A LOG-NORMAL GRAPH.)

PERCENT OF TIME CHI/Q IS EQUALED OR EXCEEDED CHI/Q WITH RESPECT TO WHEN THE WIND BLOWS SEC/CUBIC METER THE TOTAL TIME INTO THIS SECTOR ONLY HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 3)=

0.180 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 4)=

0.712 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 5)=

0.852 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 6)=

1.915 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 8)=

3.979 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 9)=

4.519 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE(10)=

4.959 K I XQSAVE(K,I) XQINT(K,I) XQSLOP(K,I) 8 1 -7.80382 -9.90923 -0.58508 8 2 -8.19329 -11.53529 -1.13950 8 3 -8.21777 -11.62530 -1.17042 8 4 -8.75619 -12.72940 -1.62083 8 5 -8.86204 -12.89777 -1.69139 8 6 -9.39390 -10.79498 -0.67633 8 7 -9.47021 -14.19192 -2.41057 8 8 -9.96594 -16.44114 -3.69356 8 9 -10.18661 -17.30962 -4.20643 8 10 -10.37408 NUMXQ(K)= 10 3.256E-04 0.066 1.000

LR-N23-0050 LAR S23-04 LAR H23-02 2.607E-04 0.198 3.000 2.150E-04 0.330 5.000 1.627E-04 0.659 10.000 1.291E-04 0.989 15.000 1.072E-04 1.318 20.000 9.234E-05 1.648 25.000 8.251E-05 1.978 30.000 7.900E-05 2.307 35.000 7.326E-05 2.637 40.000 6.474E-05 2.966 45.000 5.783E-05 3.296 50.000 5.212E-05 3.626 55.000 4.733E-05 3.955 60.000 4.140E-05 4.285 65.000 3.619E-05 4.615 70.000 3.148E-05 4.944 75.000 1.823E-04 0.5 7.58 ANNUAL AVERAGE = 2.22E-06 K= 8 FIVEXQ(K)= 1.823E-04 FIVEPR(K)= 7.585

LR-N23-0050 LAR S23-04 LAR H23-02 USNRC COMPUTER CODE-PAVAN, VERSION 2.0 RUN DATE: 03-03-2023 PLANT NAME: SGS EAB METEOROLOGICAL INSTRUMENTATION DATA PERIOD: 2019-2021 WIND SENSORS HEIGHT: 10 m TYPE OF RELEASE: Ground Level DELTA-T HEIGHTS: 10 m - 46 m SOURCE OF DATA: A-5-ZZ-MDC-2391 COMMENTS: 695 m and 790 m EAB PROGRAM: PAVAN, 10/76, 8/79 REVISION, IMPLEMENTATION OF REGULATORY GUIDE 1.145 SITE EXCLUSION BOUNDARY CALCULATIONS:

N SECTOR BOUNDARY DISTANCE = 695.0 METERS LATERAL PLUME MEANDER/BUILDING WAKE CREDIT ALLOWED AS A FUNCTION OF DOWNWIND DISTANCE.

MEANDER CREDIT IS FOR WINDSPEEDS LESS THAN 6 MPS.

BUILDING WAKE CREDIT ALLOWED: C= 0.5 A= 2399. D= 58.3 BELOW ARE PRINTED THE ORDERED VALUES OF CHI/Q AND THE FREQUENCY WITH WHICH THAT VALUE IS REACHED OR EXCEEDED.

THE TOP NUMBER IS THE CHI/Q. THE MIDDLE NUMBER IS THE FREQUENCY NORMALIZED TO THIS SECTOR.

THE THIRD NUMBER IS THE FREQUENCY WITH RESPECT TO ALL TIME.

8.572E-04 4.082E-04 2.797E-04 2.765E-04 2.698E-04 2.177E-04 2.116E-04 1.828E-04 1.697E-04 1.585E-04 0.068 0.548 1.370 2.055 2.466 2.945 3.562 4.658 5.342 5.822 0.00400 0.03202 0.08005 0.12008 0.14409 0.17211 0.20813 0.27217 0.31220 0.34022 1.575E-04 1.426E-04 1.417E-04 1.186E-04 1.174E-04 1.074E-04 1.065E-04 9.511E-05 8.571E-05 8.323E-05 7.877 9.110 9.315 10.274 10.479 11.986 12.603 13.356 13.973 22.808 0.46029 0.53234 0.54435 0.60038 0.61239 0.70045 0.73647 0.78050 0.81652 1.33285 8.323E-05 8.063E-05 7.951E-05 7.939E-05 7.711E-05 6.184E-05 6.107E-05 5.967E-05 5.714E-05 5.462E-05 26.301 26.370 27.740 28.219 34.521 40.068 42.603 43.425 43.699 43.767 1.53698 1.54099 1.62104 1.64906 2.01729 2.34150 2.48959 2.53762 2.55363 2.55764 5.274E-05 5.162E-05 4.803E-05 4.697E-05 4.130E-05 3.880E-05 3.767E-05 3.202E-05 3.144E-05 3.123E-05 52.260 55.411 55.959 63.151 63.219 65.137 72.945 73.288 80.068 80.548 3.05395 3.23807 3.27009 3.69036 3.69436 3.80644 4.26273 4.28274 4.67899 4.70701 2.776E-05 2.363E-05 2.090E-05 2.082E-05 1.902E-05 1.676E-05 1.399E-05 1.329E-05 1.268E-05 1.052E-05 81.438 86.575 87.329 87.466 88.014 88.630 89.315 89.795 90.000 91.096 4.75905 5.05924 5.10327 5.11127 5.14329 5.17932 5.21934 5.24736 5.25937 5.32341

LR-N23-0050 LAR S23-04 LAR H23-02 1.001E-05 9.826E-06 8.466E-06 8.025E-06 6.698E-06 6.656E-06 5.034E-06 5.033E-06 4.052E-06 3.383E-06 91.712 91.781 91.849 92.192 92.329 92.945 93.562 93.904 93.973 94.932 5.35943 5.36343 5.36744 5.38745 5.39545 5.43148 5.46750 5.48751 5.49152 5.54755 2.548E-06 2.043E-06 1.705E-06 1.282E-06 1.032E-06 6.878E-07 96.438 98.219 99.041 99.726 99.932 100.000 5.63561 5.73968 5.78771 5.82773 5.83974 5.84374 X/Q PERCENTILES (BASED ON THE UPPER ENVELOPE OF THE ORDERED X/Q-FREQUENCY VALUES, AND AS PLOTTED ON A LOG-NORMAL GRAPH.)

PERCENT OF TIME CHI/Q IS EQUALED OR EXCEEDED CHI/Q WITH RESPECT TO WHEN THE WIND BLOWS SEC/CUBIC METER THE TOTAL TIME INTO THIS SECTOR ONLY HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 2)=

0.144 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 3)=

0.460 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 4)=

1.331 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 7)=

3.687 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 8)=

4.259 K I XQSAVE(K,I) XQINT(K,I) XQSLOP(K,I) 9 1 -7.06188 -11.79176 -1.19917 9 2 -8.21777 -12.48935 -1.43323 9 3 -8.75619 -13.03977 -1.64455 9 4 -9.39390 -9.39390 0.00000 9 5 -9.39390 -10.88983 -0.69228 9 6 -9.47021 -13.34392 -1.88903 9 7 -9.96594 -15.86927 -3.30126 9 8 -10.18661 NUMXQ(K)= 8 3.713E-04 0.058 1.000 2.474E-04 0.175 3.000 1.958E-04 0.292 5.000

LR-N23-0050 LAR S23-04 LAR H23-02 1.374E-04 0.584 10.000 1.081E-04 0.877 15.000 9.047E-05 1.169 20.000 8.323E-05 1.461 25.000 8.024E-05 1.753 30.000 7.629E-05 2.045 35.000 6.864E-05 2.337 40.000 6.241E-05 2.630 45.000 5.724E-05 2.922 50.000 5.285E-05 3.214 55.000 4.909E-05 3.506 60.000 4.496E-05 3.798 65.000 4.015E-05 4.091 70.000 1.503E-04 0.5 8.56 ANNUAL AVERAGE = 2.05E-06 K= 9 FIVEXQ(K)= 1.503E-04 FIVEPR(K)= 8.556

LR-N23-0050 LAR S23-04 LAR H23-02 USNRC COMPUTER CODE-PAVAN, VERSION 2.0 RUN DATE: 03-03-2023 PLANT NAME: SGS EAB METEOROLOGICAL INSTRUMENTATION DATA PERIOD: 2019-2021 WIND SENSORS HEIGHT: 10 m TYPE OF RELEASE: Ground Level DELTA-T HEIGHTS: 10 m - 46 m SOURCE OF DATA: A-5-ZZ-MDC-2391 COMMENTS: 695 m and 790 m EAB PROGRAM: PAVAN, 10/76, 8/79 REVISION, IMPLEMENTATION OF REGULATORY GUIDE 1.145 SITE EXCLUSION BOUNDARY CALCULATIONS:

NNE SECTOR BOUNDARY DISTANCE = 695.0 METERS LATERAL PLUME MEANDER/BUILDING WAKE CREDIT ALLOWED AS A FUNCTION OF DOWNWIND DISTANCE.

MEANDER CREDIT IS FOR WINDSPEEDS LESS THAN 6 MPS.

BUILDING WAKE CREDIT ALLOWED: C= 0.5 A= 2399. D= 58.3 BELOW ARE PRINTED THE ORDERED VALUES OF CHI/Q AND THE FREQUENCY WITH WHICH THAT VALUE IS REACHED OR EXCEEDED.

THE TOP NUMBER IS THE CHI/Q. THE MIDDLE NUMBER IS THE FREQUENCY NORMALIZED TO THIS SECTOR.

THE THIRD NUMBER IS THE FREQUENCY WITH RESPECT TO ALL TIME.

4.082E-04 2.797E-04 2.765E-04 2.698E-04 2.177E-04 2.116E-04 1.828E-04 1.697E-04 1.585E-04 1.575E-04 0.346 1.245 1.729 1.936 2.420 3.043 4.149 5.187 6.086 8.160 0.02001 0.07205 0.10006 0.11207 0.14009 0.17611 0.24015 0.30019 0.35223 0.47230 1.426E-04 1.417E-04 1.186E-04 1.174E-04 1.074E-04 1.065E-04 9.511E-05 8.571E-05 8.323E-05 8.323E-05 9.474 10.166 11.549 11.826 14.315 14.869 15.837 16.390 32.089 37.690 0.54835 0.58838 0.66843 0.68444 0.82853 0.86055 0.91659 0.94861 1.85719 2.18140 8.063E-05 7.951E-05 7.939E-05 7.711E-05 6.184E-05 6.107E-05 5.967E-05 5.462E-05 5.274E-05 5.162E-05 37.828 39.350 40.456 51.521 57.538 60.028 61.411 61.618 70.055 73.375 2.18940 2.27746 2.34150 2.98191 3.33013 3.47422 3.55428 3.56628 4.05460 4.24672 4.803E-05 4.697E-05 4.130E-05 3.880E-05 3.767E-05 3.202E-05 3.144E-05 3.123E-05 2.776E-05 2.614E-05 73.790 81.051 81.259 82.780 88.243 88.382 90.387 90.456 91.978 92.047 4.27073 4.69100 4.70301 4.79107 5.10727 5.11527 5.23135 5.23535 5.32341 5.32741 2.363E-05 2.090E-05 1.977E-05 1.676E-05 1.399E-05 1.329E-05 1.052E-05 1.001E-05 9.826E-06 8.025E-06 92.808 93.223 93.361 93.707 93.845 94.606 94.675 95.297 95.505 95.712 5.37144 5.39545 5.40346 5.42347 5.43148 5.47550 5.47951 5.51553 5.52754 5.53955

LR-N23-0050 LAR S23-04 LAR H23-02 6.698E-06 6.656E-06 5.033E-06 3.383E-06 2.548E-06 2.043E-06 1.705E-06 1.282E-06 1.032E-06 6.878E-07 95.781 96.127 96.680 97.510 98.271 98.617 99.585 99.862 99.931 100.000 5.54355 5.56356 5.59558 5.64361 5.68764 5.70765 5.76369 5.77970 5.78370 5.78770 X/Q PERCENTILES (BASED ON THE UPPER ENVELOPE OF THE ORDERED X/Q-FREQUENCY VALUES, AND AS PLOTTED ON A LOG-NORMAL GRAPH.)

PERCENT OF TIME CHI/Q IS EQUALED OR EXCEEDED CHI/Q WITH RESPECT TO WHEN THE WIND BLOWS SEC/CUBIC METER THE TOTAL TIME INTO THIS SECTOR ONLY HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 3)=

0.472 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 4)=

1.855 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 7)=

4.687 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 8)=

5.104 K I XQSAVE(K,I) XQINT(K,I) XQSLOP(K,I) 10 1 -7.80382 -10.83432 -0.85605 10 2 -8.21777 -11.79039 -1.16885 10 3 -8.75619 -11.99409 -1.24732 10 4 -9.39390 -9.39390 0.00000 10 5 -9.39390 -10.54149 -0.56865 10 6 -9.47021 -13.96162 -2.38413 10 7 -9.96594 -18.97402 -5.37491 10 8 -10.18661 NUMXQ(K)= 8 3.183E-04 0.058 1.000 2.308E-04 0.174 3.000 1.908E-04 0.289 5.000 1.442E-04 0.579 10.000 1.202E-04 0.868 15.000 1.051E-04 1.158 20.000 9.430E-05 1.447 25.000 8.612E-05 1.736 30.000 8.323E-05 2.026 35.000

LR-N23-0050 LAR S23-04 LAR H23-02 8.205E-05 2.315 40.000 7.974E-05 2.604 45.000 7.769E-05 2.894 50.000 7.197E-05 3.183 55.000 6.557E-05 3.473 60.000 6.011E-05 3.762 65.000 5.540E-05 4.051 70.000 5.129E-05 4.341 75.000 4.768E-05 4.630 80.000 4.154E-05 4.920 85.000 1.537E-04 0.5 8.64 ANNUAL AVERAGE = 2.27E-06 K= 10 FIVEXQ(K)= 1.537E-04 FIVEPR(K)= 8.639

LR-N23-0050 LAR S23-04 LAR H23-02 USNRC COMPUTER CODE-PAVAN, VERSION 2.0 RUN DATE: 03-03-2023 PLANT NAME: SGS EAB METEOROLOGICAL INSTRUMENTATION DATA PERIOD: 2019-2021 WIND SENSORS HEIGHT: 10 m TYPE OF RELEASE: Ground Level DELTA-T HEIGHTS: 10 m - 46 m SOURCE OF DATA: A-5-ZZ-MDC-2391 COMMENTS: 695 m and 790 m EAB PROGRAM: PAVAN, 10/76, 8/79 REVISION, IMPLEMENTATION OF REGULATORY GUIDE 1.145 SITE EXCLUSION BOUNDARY CALCULATIONS:

NE SECTOR BOUNDARY DISTANCE = 695.0 METERS LATERAL PLUME MEANDER/BUILDING WAKE CREDIT ALLOWED AS A FUNCTION OF DOWNWIND DISTANCE.

MEANDER CREDIT IS FOR WINDSPEEDS LESS THAN 6 MPS.

BUILDING WAKE CREDIT ALLOWED: C= 0.5 A= 2399. D= 58.3 BELOW ARE PRINTED THE ORDERED VALUES OF CHI/Q AND THE FREQUENCY WITH WHICH THAT VALUE IS REACHED OR EXCEEDED.

THE TOP NUMBER IS THE CHI/Q. THE MIDDLE NUMBER IS THE FREQUENCY NORMALIZED TO THIS SECTOR.

THE THIRD NUMBER IS THE FREQUENCY WITH RESPECT TO ALL TIME.

4.082E-04 2.797E-04 2.765E-04 2.698E-04 2.177E-04 2.116E-04 1.828E-04 1.697E-04 1.585E-04 1.575E-04 0.132 1.516 1.780 2.637 2.769 3.560 4.417 4.878 5.603 11.734 0.00801 0.09206 0.10807 0.16010 0.16811 0.21614 0.26817 0.29619 0.34022 0.71246 1.426E-04 1.417E-04 1.186E-04 1.174E-04 1.074E-04 9.511E-05 8.323E-05 8.323E-05 7.951E-05 7.939E-05 13.975 14.305 16.941 17.139 19.644 21.490 41.595 47.462 48.253 49.506 0.84854 0.86856 1.02866 1.04067 1.19276 1.30484 2.52562 2.88184 2.92988 3.00592 7.711E-05 6.184E-05 6.107E-05 5.967E-05 5.462E-05 5.274E-05 5.162E-05 4.803E-05 4.697E-05 4.130E-05 62.294 66.249 68.161 69.018 69.150 76.203 78.115 78.444 84.443 84.575 3.78242 4.02257 4.13865 4.19068 4.19869 4.62696 4.74304 4.76305 5.12728 5.13529 3.880E-05 3.859E-05 3.767E-05 3.144E-05 2.776E-05 2.363E-05 2.090E-05 1.977E-05 1.676E-05 1.329E-05 85.827 85.893 87.937 88.662 90.046 90.508 91.167 91.365 91.826 92.353 5.21134 5.21534 5.33942 5.38345 5.46750 5.49552 5.53554 5.54755 5.57557 5.60759 1.052E-05 1.001E-05 8.025E-06 6.698E-06 6.656E-06 5.034E-06 5.033E-06 3.383E-06 2.548E-06 2.043E-06 92.419 92.881 93.210 93.276 93.408 93.474 93.804 95.517 97.825 99.539 5.61159 5.63961 5.65962 5.66362 5.67163 5.67563 5.69564 5.79971 5.93980 6.04387

LR-N23-0050 LAR S23-04 LAR H23-02 1.705E-06 1.282E-06 1.032E-06 99.868 99.934 100.000 6.06388 6.06788 6.07188 X/Q PERCENTILES (BASED ON THE UPPER ENVELOPE OF THE ORDERED X/Q-FREQUENCY VALUES, AND AS PLOTTED ON A LOG-NORMAL GRAPH.)

PERCENT OF TIME CHI/Q IS EQUALED OR EXCEEDED CHI/Q WITH RESPECT TO WHEN THE WIND BLOWS SEC/CUBIC METER THE TOTAL TIME INTO THIS SECTOR ONLY HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 3)=

0.712 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 4)=

2.879 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 6)=

5.124 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 7)=

5.336 K I XQSAVE(K,I) XQINT(K,I) XQSLOP(K,I) 11 1 -7.80382 -9.69340 -0.50056 11 2 -8.21777 -11.41386 -1.08417 11 3 -8.75619 -11.58570 -1.15427 11 4 -9.39390 -10.58211 -0.62574 11 5 -9.47021 -15.59068 -3.44444 11 6 -9.96594 -28.12471 -11.11996 11 7 -10.18661 NUMXQ(K)= 7 3.116E-04 0.061 1.000 2.583E-04 0.182 3.000 2.163E-04 0.304 5.000 1.675E-04 0.607 10.000 1.420E-04 0.911 15.000 1.253E-04 1.214 20.000 1.133E-04 1.518 25.000 1.041E-04 1.822 30.000 9.672E-05 2.125 35.000 9.064E-05 2.429 40.000

LR-N23-0050 LAR S23-04 LAR H23-02 8.549E-05 2.732 45.000 8.205E-05 3.036 50.000 7.989E-05 3.340 55.000 7.795E-05 3.643 60.000 7.208E-05 3.947 65.000 6.399E-05 4.250 70.000 5.719E-05 4.554 75.000 5.141E-05 4.858 80.000 4.533E-05 5.161 85.000 1.803E-04 0.5 8.23 ANNUAL AVERAGE = 2.51E-06 K= 11 FIVEXQ(K)= 1.803E-04 FIVEPR(K)= 8.235

LR-N23-0050 LAR S23-04 LAR H23-02 USNRC COMPUTER CODE-PAVAN, VERSION 2.0 RUN DATE: 03-03-2023 PLANT NAME: SGS EAB METEOROLOGICAL INSTRUMENTATION DATA PERIOD: 2019-2021 WIND SENSORS HEIGHT: 10 m TYPE OF RELEASE: Ground Level DELTA-T HEIGHTS: 10 m - 46 m SOURCE OF DATA: A-5-ZZ-MDC-2391 COMMENTS: 695 m and 790 m EAB PROGRAM: PAVAN, 10/76, 8/79 REVISION, IMPLEMENTATION OF REGULATORY GUIDE 1.145 SITE EXCLUSION BOUNDARY CALCULATIONS:

ENE SECTOR BOUNDARY DISTANCE = 695.0 METERS LATERAL PLUME MEANDER/BUILDING WAKE CREDIT ALLOWED AS A FUNCTION OF DOWNWIND DISTANCE.

MEANDER CREDIT IS FOR WINDSPEEDS LESS THAN 6 MPS.

BUILDING WAKE CREDIT ALLOWED: C= 0.5 A= 2399. D= 58.3 BELOW ARE PRINTED THE ORDERED VALUES OF CHI/Q AND THE FREQUENCY WITH WHICH THAT VALUE IS REACHED OR EXCEEDED.

THE TOP NUMBER IS THE CHI/Q. THE MIDDLE NUMBER IS THE FREQUENCY NORMALIZED TO THIS SECTOR.

THE THIRD NUMBER IS THE FREQUENCY WITH RESPECT TO ALL TIME.

3.329E-04 2.797E-04 2.765E-04 2.698E-04 2.177E-04 2.116E-04 1.828E-04 1.697E-04 1.585E-04 1.575E-04 0.066 0.795 0.927 1.391 1.656 1.921 2.583 2.649 3.510 8.609 0.00400 0.04803 0.05604 0.08405 0.10006 0.11607 0.15610 0.16010 0.21214 0.52033 1.426E-04 1.186E-04 1.174E-04 1.074E-04 9.511E-05 8.323E-05 8.323E-05 8.063E-05 7.951E-05 7.939E-05 10.066 13.046 13.179 16.159 17.417 34.768 39.735 39.801 40.596 40.927 0.60839 0.78850 0.79651 0.97663 1.05267 2.10134 2.40154 2.40554 2.45357 2.47358 7.711E-05 6.184E-05 6.107E-05 5.967E-05 5.274E-05 5.162E-05 4.697E-05 4.130E-05 3.880E-05 3.767E-05 55.894 60.066 61.987 62.053 67.152 68.344 75.828 76.026 76.358 80.132 3.37816 3.63032 3.74640 3.75040 4.05860 4.13064 4.58293 4.59494 4.61495 4.84310 3.144E-05 3.123E-05 2.776E-05 2.363E-05 2.090E-05 1.977E-05 1.902E-05 1.676E-05 1.399E-05 1.329E-05 82.649 82.781 83.576 85.364 85.960 86.225 86.424 87.020 87.219 87.417 4.99520 5.00320 5.05123 5.15930 5.19532 5.21134 5.22334 5.25937 5.27137 5.28338 1.052E-05 1.001E-05 9.826E-06 8.025E-06 6.698E-06 6.656E-06 5.034E-06 5.033E-06 3.383E-06 2.548E-06 87.682 88.477 88.675 89.073 89.272 89.338 89.470 89.735 92.053 95.298 5.29939 5.34742 5.35943 5.38345 5.39545 5.39946 5.40746 5.42347 5.56356 5.75969

LR-N23-0050 LAR S23-04 LAR H23-02 2.043E-06 1.705E-06 1.282E-06 98.411 99.735 100.000 5.94781 6.02786 6.04387 X/Q PERCENTILES (BASED ON THE UPPER ENVELOPE OF THE ORDERED X/Q-FREQUENCY VALUES, AND AS PLOTTED ON A LOG-NORMAL GRAPH.)

PERCENT OF TIME CHI/Q IS EQUALED OR EXCEEDED CHI/Q WITH RESPECT TO WHEN THE WIND BLOWS SEC/CUBIC METER THE TOTAL TIME INTO THIS SECTOR ONLY HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 4)=

2.399 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 6)=

4.579 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 7)=

4.839 K I XQSAVE(K,I) XQINT(K,I) XQSLOP(K,I) 12 1 -8.00756 -9.04066 -0.26192 12 2 -8.21777 -11.13777 -0.92942 12 3 -8.75619 -11.54996 -1.09028 12 4 -9.39390 -10.40534 -0.51147 12 5 -9.47021 -15.88758 -3.50998 12 6 -9.96594 -24.03577 -8.33973 12 7 -10.18661 NUMXQ(K)= 7 2.766E-04 0.060 1.000 2.174E-04 0.181 3.000 1.867E-04 0.302 5.000 1.487E-04 0.604 10.000 1.268E-04 0.907 15.000 1.126E-04 1.209 20.000 1.024E-04 1.511 25.000 9.454E-05 1.813 30.000 8.822E-05 2.115 35.000 8.311E-05 2.418 40.000 8.099E-05 2.720 45.000 7.910E-05 3.022 50.000

LR-N23-0050 LAR S23-04 LAR H23-02 7.740E-05 3.324 55.000 6.889E-05 3.626 60.000 6.055E-05 3.929 65.000 5.364E-05 4.231 70.000 4.784E-05 4.533 75.000 3.792E-05 4.835 80.000 1.595E-04 0.5 8.27 ANNUAL AVERAGE = 2.21E-06 K= 12 FIVEXQ(K)= 1.595E-04 FIVEPR(K)= 8.273

LR-N23-0050 LAR S23-04 LAR H23-02 USNRC COMPUTER CODE-PAVAN, VERSION 2.0 RUN DATE: 03-03-2023 PLANT NAME: SGS EAB METEOROLOGICAL INSTRUMENTATION DATA PERIOD: 2019-2021 WIND SENSORS HEIGHT: 10 m TYPE OF RELEASE: Ground Level DELTA-T HEIGHTS: 10 m - 46 m SOURCE OF DATA: A-5-ZZ-MDC-2391 COMMENTS: 695 m and 790 m EAB PROGRAM: PAVAN, 10/76, 8/79 REVISION, IMPLEMENTATION OF REGULATORY GUIDE 1.145 SITE EXCLUSION BOUNDARY CALCULATIONS:

E SECTOR BOUNDARY DISTANCE = 695.0 METERS LATERAL PLUME MEANDER/BUILDING WAKE CREDIT ALLOWED AS A FUNCTION OF DOWNWIND DISTANCE.

MEANDER CREDIT IS FOR WINDSPEEDS LESS THAN 6 MPS.

BUILDING WAKE CREDIT ALLOWED: C= 0.5 A= 2399. D= 58.3 BELOW ARE PRINTED THE ORDERED VALUES OF CHI/Q AND THE FREQUENCY WITH WHICH THAT VALUE IS REACHED OR EXCEEDED.

THE TOP NUMBER IS THE CHI/Q. THE MIDDLE NUMBER IS THE FREQUENCY NORMALIZED TO THIS SECTOR.

THE THIRD NUMBER IS THE FREQUENCY WITH RESPECT TO ALL TIME.

4.082E-04 3.329E-04 2.797E-04 2.765E-04 2.698E-04 2.465E-04 2.177E-04 1.828E-04 1.585E-04 1.575E-04 0.342 0.410 0.615 0.957 1.572 1.640 1.982 3.076 3.828 7.109 0.02001 0.02402 0.03602 0.05604 0.09206 0.09606 0.11607 0.18012 0.22414 0.41627 1.426E-04 1.186E-04 1.174E-04 1.074E-04 9.511E-05 8.323E-05 8.323E-05 8.105E-05 8.063E-05 7.951E-05 9.296 11.141 11.483 14.149 14.627 27.683 31.784 31.852 31.921 32.536 0.54435 0.65242 0.67243 0.82853 0.85655 1.62104 1.86119 1.86519 1.86920 1.90522 7.711E-05 6.184E-05 6.107E-05 5.967E-05 5.462E-05 5.274E-05 5.162E-05 4.697E-05 4.130E-05 3.880E-05 42.994 48.052 50.103 50.171 50.239 53.862 55.502 59.535 59.672 61.517 2.51761 2.81380 2.93388 2.93788 2.94188 3.15402 3.25008 3.48623 3.49424 3.60230 3.767E-05 3.144E-05 3.123E-05 2.776E-05 2.614E-05 2.363E-05 2.090E-05 2.082E-05 1.977E-05 1.902E-05 67.532 71.087 71.702 72.591 72.659 77.239 78.195 78.401 78.469 79.973 3.95453 4.16266 4.19869 4.25072 4.25472 4.52289 4.57893 4.59094 4.59494 4.68300 1.676E-05 1.399E-05 1.329E-05 1.268E-05 1.052E-05 1.001E-05 9.826E-06 8.466E-06 8.025E-06 6.698E-06 80.725 81.066 81.887 82.433 82.707 83.459 83.527 83.664 84.416 85.373 4.72702 4.74704 4.79507 4.82709 4.84310 4.88713 4.89113 4.89913 4.94316 4.99920

LR-N23-0050 LAR S23-04 LAR H23-02 6.656E-06 5.644E-06 5.034E-06 5.033E-06 4.052E-06 3.383E-06 2.702E-06 2.548E-06 2.043E-06 1.705E-06 85.509 85.578 86.398 86.466 86.603 87.286 87.355 89.200 92.413 94.668 5.00720 5.01121 5.05924 5.06324 5.07124 5.11127 5.11527 5.22334 5.41146 5.54355 1.282E-06 1.032E-06 6.878E-07 98.496 99.658 100.000 5.76769 5.83573 5.85575 X/Q PERCENTILES (BASED ON THE UPPER ENVELOPE OF THE ORDERED X/Q-FREQUENCY VALUES, AND AS PLOTTED ON A LOG-NORMAL GRAPH.)

PERCENT OF TIME CHI/Q IS EQUALED OR EXCEEDED CHI/Q WITH RESPECT TO WHEN THE WIND BLOWS SEC/CUBIC METER THE TOTAL TIME INTO THIS SECTOR ONLY HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 3)=

0.544 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 4)=

1.859 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 6)=

3.483 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 7)=

3.951 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 8)=

4.195 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 9)=

4.519 K I XQSAVE(K,I) XQINT(K,I) XQSLOP(K,I) 13 1 -7.80382 -11.25127 -0.97383 13 2 -8.21777 -11.71442 -1.12252 13 3 -8.85568 -11.81627 -1.16251 13 4 -9.39390 -10.65248 -0.60400 13 5 -9.47021 -16.24208 -3.45964 13 6 -9.96594 -16.90121 -3.82298 13 7 -10.18661 -21.98237 -6.71595 13 8 -10.37408 -24.10258 -7.94260 13 9 -10.65290 NUMXQ(K)= 9

LR-N23-0050 LAR S23-04 LAR H23-02 3.065E-04 0.059 1.000 2.166E-04 0.176 3.000 1.803E-04 0.293 5.000 1.384E-04 0.586 10.000 1.168E-04 0.878 15.000 1.030E-04 1.171 20.000 9.310E-05 1.464 25.000 8.554E-05 1.757 30.000 8.126E-05 2.050 35.000 7.856E-05 2.342 40.000 7.206E-05 2.635 45.000 6.149E-05 2.928 50.000 5.313E-05 3.221 55.000 4.634E-05 3.513 60.000 4.030E-05 3.806 65.000 3.368E-05 4.099 70.000 2.640E-05 4.392 75.000 1.474E-04 0.5 8.54 ANNUAL AVERAGE = 2.00E-06 K= 13 FIVEXQ(K)= 1.474E-04 FIVEPR(K)= 8.539

LR-N23-0050 LAR S23-04 LAR H23-02 USNRC COMPUTER CODE-PAVAN, VERSION 2.0 RUN DATE: 03-03-2023 PLANT NAME: SGS EAB METEOROLOGICAL INSTRUMENTATION DATA PERIOD: 2019-2021 WIND SENSORS HEIGHT: 10 m TYPE OF RELEASE: Ground Level DELTA-T HEIGHTS: 10 m - 46 m SOURCE OF DATA: A-5-ZZ-MDC-2391 COMMENTS: 695 m and 790 m EAB PROGRAM: PAVAN, 10/76, 8/79 REVISION, IMPLEMENTATION OF REGULATORY GUIDE 1.145 SITE EXCLUSION BOUNDARY CALCULATIONS:

ESE SECTOR BOUNDARY DISTANCE = 695.0 METERS LATERAL PLUME MEANDER/BUILDING WAKE CREDIT ALLOWED AS A FUNCTION OF DOWNWIND DISTANCE.

MEANDER CREDIT IS FOR WINDSPEEDS LESS THAN 6 MPS.

BUILDING WAKE CREDIT ALLOWED: C= 0.5 A= 2399. D= 58.3 BELOW ARE PRINTED THE ORDERED VALUES OF CHI/Q AND THE FREQUENCY WITH WHICH THAT VALUE IS REACHED OR EXCEEDED.

THE TOP NUMBER IS THE CHI/Q. THE MIDDLE NUMBER IS THE FREQUENCY NORMALIZED TO THIS SECTOR.

THE THIRD NUMBER IS THE FREQUENCY WITH RESPECT TO ALL TIME.

4.082E-04 2.797E-04 2.765E-04 2.698E-04 2.177E-04 2.116E-04 1.828E-04 1.585E-04 1.575E-04 1.426E-04 0.062 0.125 0.374 1.059 1.432 1.494 2.553 3.861 6.476 7.846 0.00400 0.00801 0.02402 0.06804 0.09206 0.09606 0.16411 0.24816 0.41627 0.50432 1.186E-04 1.174E-04 1.074E-04 9.511E-05 8.323E-05 8.323E-05 7.951E-05 7.711E-05 6.184E-05 6.107E-05 9.153 9.340 12.391 12.453 23.163 28.518 29.826 39.103 44.707 46.326 0.58838 0.60038 0.79651 0.80051 1.48895 1.83317 1.91723 2.51361 2.87384 2.97791 5.462E-05 5.274E-05 5.162E-05 4.697E-05 3.880E-05 3.859E-05 3.767E-05 3.144E-05 3.123E-05 2.776E-05 46.389 51.308 53.051 57.721 59.963 60.025 64.882 68.618 69.427 70.112 2.98191 3.29811 3.41018 3.71037 3.85447 3.85847 4.17067 4.41082 4.46286 4.50688 2.614E-05 2.363E-05 2.090E-05 2.082E-05 1.977E-05 1.902E-05 1.676E-05 1.399E-05 1.329E-05 1.268E-05 70.174 75.841 76.339 76.401 76.526 78.269 78.767 79.514 79.950 80.262 4.51089 4.87512 4.90714 4.91114 4.91915 5.03122 5.06324 5.11127 5.13929 5.15930 1.052E-05 1.001E-05 8.466E-06 8.025E-06 6.698E-06 6.656E-06 5.644E-06 5.034E-06 5.033E-06 4.052E-06 81.445 81.880 82.316 82.752 83.437 83.748 83.811 85.430 85.990 86.675 5.23535 5.26337 5.29139 5.31940 5.36343 5.38345 5.38745 5.49151 5.52754 5.57157

LR-N23-0050 LAR S23-04 LAR H23-02 3.383E-06 2.702E-06 2.548E-06 2.043E-06 1.705E-06 1.282E-06 1.032E-06 6.878E-07 87.796 88.045 89.352 91.469 93.960 97.198 99.315 100.000 5.64361 5.65962 5.74368 5.87976 6.03987 6.24800 6.38409 6.42811 X/Q PERCENTILES (BASED ON THE UPPER ENVELOPE OF THE ORDERED X/Q-FREQUENCY VALUES, AND AS PLOTTED ON A LOG-NORMAL GRAPH.)

PERCENT OF TIME CHI/Q IS EQUALED OR EXCEEDED CHI/Q WITH RESPECT TO WHEN THE WIND BLOWS SEC/CUBIC METER THE TOTAL TIME INTO THIS SECTOR ONLY HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 4)=

2.511 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 5)=

3.707 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 6)=

4.167 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 7)=

4.459 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 8)=

4.871 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 9)=

5.028 K I XQSAVE(K,I) XQINT(K,I) XQSLOP(K,I) 14 1 -7.80382 -10.00662 -0.55848 14 2 -8.21777 -11.27505 -0.95448 14 3 -8.75619 -11.52350 -1.04863 14 4 -9.47021 -15.10250 -2.87645 14 5 -9.96594 -17.24572 -4.07664 14 6 -10.18661 -20.36440 -5.87768 14 7 -10.37408 -21.58835 -6.59777 14 8 -10.65290 -34.21951 -14.21862 14 9 -10.86981 NUMXQ(K)= 9 2.723E-04 0.064 1.000 2.001E-04 0.193 3.000 1.710E-04 0.321 5.000 1.344E-04 0.643 10.000

LR-N23-0050 LAR S23-04 LAR H23-02 1.152E-04 0.964 15.000 1.027E-04 1.286 20.000 9.363E-05 1.607 25.000 8.665E-05 1.928 30.000 8.101E-05 2.250 35.000 7.499E-05 2.571 40.000 6.473E-05 2.893 45.000 5.661E-05 3.214 50.000 5.004E-05 3.535 55.000 4.369E-05 3.857 60.000 3.748E-05 4.178 65.000 3.044E-05 4.500 70.000 2.448E-05 4.821 75.000 1.475E-04 0.5 7.78 ANNUAL AVERAGE = 2.07E-06 K= 14 FIVEXQ(K)= 1.475E-04 FIVEPR(K)= 7.778

LR-N23-0050 LAR S23-04 LAR H23-02 USNRC COMPUTER CODE-PAVAN, VERSION 2.0 RUN DATE: 03-03-2023 PLANT NAME: SGS EAB METEOROLOGICAL INSTRUMENTATION DATA PERIOD: 2019-2021 WIND SENSORS HEIGHT: 10 m TYPE OF RELEASE: Ground Level DELTA-T HEIGHTS: 10 m - 46 m SOURCE OF DATA: A-5-ZZ-MDC-2391 COMMENTS: 695 m and 790 m EAB PROGRAM: PAVAN, 10/76, 8/79 REVISION, IMPLEMENTATION OF REGULATORY GUIDE 1.145 SITE EXCLUSION BOUNDARY CALCULATIONS:

SE SECTOR BOUNDARY DISTANCE = 695.0 METERS LATERAL PLUME MEANDER/BUILDING WAKE CREDIT ALLOWED AS A FUNCTION OF DOWNWIND DISTANCE.

MEANDER CREDIT IS FOR WINDSPEEDS LESS THAN 6 MPS.

BUILDING WAKE CREDIT ALLOWED: C= 0.5 A= 2399. D= 58.3 BELOW ARE PRINTED THE ORDERED VALUES OF CHI/Q AND THE FREQUENCY WITH WHICH THAT VALUE IS REACHED OR EXCEEDED.

THE TOP NUMBER IS THE CHI/Q. THE MIDDLE NUMBER IS THE FREQUENCY NORMALIZED TO THIS SECTOR.

THE THIRD NUMBER IS THE FREQUENCY WITH RESPECT TO ALL TIME.

5.666E-04 4.082E-04 2.797E-04 2.765E-04 2.698E-04 2.177E-04 2.116E-04 1.828E-04 1.585E-04 1.575E-04 0.073 0.110 0.879 1.136 1.539 1.942 2.272 3.115 3.738 10.150 0.00801 0.01201 0.09606 0.12408 0.16811 0.21214 0.24816 0.34022 0.40826 1.10871 1.426E-04 1.186E-04 1.174E-04 1.074E-04 9.511E-05 8.323E-05 8.323E-05 8.105E-05 8.063E-05 7.951E-05 11.763 14.657 14.804 16.306 16.636 24.918 27.483 27.519 27.556 28.069 1.28482 1.60102 1.61703 1.78114 1.81716 2.72174 3.00192 3.00592 3.00993 3.06596 7.939E-05 7.711E-05 6.184E-05 6.107E-05 5.462E-05 5.274E-05 5.162E-05 4.697E-05 4.130E-05 3.880E-05 28.106 35.581 42.690 43.679 43.716 46.501 50.678 55.112 55.332 58.703 3.06997 3.88649 4.66298 4.77105 4.77506 5.07925 5.53554 6.01985 6.04387 6.41210 3.767E-05 3.144E-05 3.123E-05 2.776E-05 2.363E-05 2.090E-05 1.977E-05 1.902E-05 1.676E-05 1.399E-05 63.357 67.571 68.010 68.487 75.009 75.449 75.522 76.768 77.831 78.747 6.92043 7.38072 7.42875 7.48079 8.19324 8.24127 8.24928 8.38537 8.50144 8.60151 1.329E-05 1.268E-05 1.052E-05 1.001E-05 9.826E-06 8.466E-06 8.025E-06 6.698E-06 6.656E-06 5.034E-06 78.930 79.040 80.066 80.762 80.835 81.129 81.678 82.484 82.594 84.097 8.62152 8.63353 8.74560 8.82165 8.82965 8.86167 8.92171 9.00977 9.02177 9.18588

LR-N23-0050 LAR S23-04 LAR H23-02 5.033E-06 4.052E-06 3.383E-06 2.548E-06 2.043E-06 1.705E-06 1.282E-06 1.032E-06 6.878E-07 84.317 84.903 85.746 87.028 89.190 92.928 96.995 99.743 100.000 9.20990 9.27394 9.36599 9.50608 9.74224 10.15050 10.59478 10.89497 10.92299 X/Q PERCENTILES (BASED ON THE UPPER ENVELOPE OF THE ORDERED X/Q-FREQUENCY VALUES, AND AS PLOTTED ON A LOG-NORMAL GRAPH.)

PERCENT OF TIME CHI/Q IS EQUALED OR EXCEEDED CHI/Q WITH RESPECT TO WHEN THE WIND BLOWS SEC/CUBIC METER THE TOTAL TIME INTO THIS SECTOR ONLY HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 3)=

2.999 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 5)=

6.016 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 6)=

6.917 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 7)=

7.425 K I XQSAVE(K,I) XQINT(K,I) XQSLOP(K,I) 15 1 -7.47583 -10.72591 -0.86096 15 2 -8.75619 -12.34187 -1.56730 15 3 -9.39390 -10.62581 -0.65495 15 4 -9.47021 -13.61602 -2.34969 15 5 -9.96594 -14.76717 -3.09073 15 6 -10.18661 -17.65954 -5.04235 15 7 -10.37408 NUMXQ(K)= 7 3.073E-04 0.109 1.000 2.283E-04 0.328 3.000 1.966E-04 0.546 5.000 1.583E-04 1.092 10.000 1.240E-04 1.638 15.000 1.031E-04 2.185 20.000 8.881E-05 2.731 25.000 8.113E-05 3.277 30.000 7.750E-05 3.823 35.000 6.782E-05 4.369 40.000

LR-N23-0050 LAR S23-04 LAR H23-02 5.942E-05 4.915 45.000 5.265E-05 5.461 50.000 4.709E-05 6.008 55.000 4.109E-05 6.554 60.000 3.522E-05 7.100 65.000 2.019E-04 0.5 4.58 ANNUAL AVERAGE = 3.30E-06 K= 15 FIVEXQ(K)= 2.019E-04 FIVEPR(K)= 4.578

LR-N23-0050 LAR S23-04 LAR H23-02 USNRC COMPUTER CODE-PAVAN, VERSION 2.0 RUN DATE: 03-03-2023 PLANT NAME: SGS EAB METEOROLOGICAL INSTRUMENTATION DATA PERIOD: 2019-2021 WIND SENSORS HEIGHT: 10 m TYPE OF RELEASE: Ground Level DELTA-T HEIGHTS: 10 m - 46 m SOURCE OF DATA: A-5-ZZ-MDC-2391 COMMENTS: 695 m and 790 m EAB PROGRAM: PAVAN, 10/76, 8/79 REVISION, IMPLEMENTATION OF REGULATORY GUIDE 1.145 SITE EXCLUSION BOUNDARY CALCULATIONS:

SSE SECTOR BOUNDARY DISTANCE = 695.0 METERS LATERAL PLUME MEANDER/BUILDING WAKE CREDIT ALLOWED AS A FUNCTION OF DOWNWIND DISTANCE.

MEANDER CREDIT IS FOR WINDSPEEDS LESS THAN 6 MPS.

BUILDING WAKE CREDIT ALLOWED: C= 0.5 A= 2399. D= 58.3 BELOW ARE PRINTED THE ORDERED VALUES OF CHI/Q AND THE FREQUENCY WITH WHICH THAT VALUE IS REACHED OR EXCEEDED.

THE TOP NUMBER IS THE CHI/Q. THE MIDDLE NUMBER IS THE FREQUENCY NORMALIZED TO THIS SECTOR.

THE THIRD NUMBER IS THE FREQUENCY WITH RESPECT TO ALL TIME.

4.082E-04 2.797E-04 2.765E-04 2.698E-04 2.465E-04 2.177E-04 2.116E-04 1.828E-04 1.697E-04 1.585E-04 0.203 2.025 2.633 3.089 3.139 3.646 4.759 5.975 6.025 6.937 0.01601 0.16010 0.20813 0.24416 0.24816 0.28818 0.37624 0.47230 0.47630 0.54835 1.575E-04 1.426E-04 1.186E-04 1.174E-04 1.074E-04 9.511E-05 8.323E-05 8.323E-05 7.951E-05 7.939E-05 12.253 13.975 16.405 16.759 18.785 19.241 28.203 31.848 32.456 32.658 0.96862 1.10471 1.29683 1.32485 1.48495 1.52097 2.22943 2.51761 2.56564 2.58165 7.711E-05 6.184E-05 6.107E-05 5.274E-05 5.162E-05 4.697E-05 4.130E-05 3.880E-05 3.767E-05 3.144E-05 39.392 45.063 45.873 51.696 54.835 61.519 61.570 64.000 68.608 73.367 3.11399 3.56228 3.62632 4.08662 4.33477 4.86311 4.86712 5.05924 5.42347 5.79971 3.123E-05 2.776E-05 2.614E-05 2.363E-05 2.090E-05 1.977E-05 1.902E-05 1.676E-05 1.399E-05 1.329E-05 73.570 73.975 74.025 79.190 80.203 80.304 81.013 82.228 83.392 83.544 5.81572 5.84774 5.85175 6.26001 6.34006 6.34806 6.40410 6.50016 6.59222 6.60423 1.268E-05 1.052E-05 1.001E-05 9.826E-06 8.466E-06 8.025E-06 6.698E-06 6.656E-06 5.034E-06 5.033E-06 83.595 84.456 84.911 84.962 85.215 85.823 86.633 86.785 87.595 87.696 6.60823 6.67627 6.71230 6.71630 6.73631 6.78434 6.84838 6.86039 6.92443 6.93244

LR-N23-0050 LAR S23-04 LAR H23-02 4.052E-06 3.383E-06 2.548E-06 2.043E-06 1.705E-06 1.282E-06 1.032E-06 87.899 88.608 89.924 92.405 95.241 98.734 100.000 6.94845 7.00448 7.10855 7.30468 7.52882 7.80500 7.90506 X/Q PERCENTILES (BASED ON THE UPPER ENVELOPE OF THE ORDERED X/Q-FREQUENCY VALUES, AND AS PLOTTED ON A LOG-NORMAL GRAPH.)

PERCENT OF TIME CHI/Q IS EQUALED OR EXCEEDED CHI/Q WITH RESPECT TO WHEN THE WIND BLOWS SEC/CUBIC METER THE TOTAL TIME INTO THIS SECTOR ONLY HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 3)=

0.967 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 4)=

2.515 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 6)=

4.859 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 7)=

5.420 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 8)=

5.812 K I XQSAVE(K,I) XQINT(K,I) XQSLOP(K,I) 16 1 -7.80382 -9.70498 -0.52832 16 2 -8.21777 -11.40007 -1.13048 16 3 -8.75619 -12.66723 -1.67230 16 4 -9.39390 -11.00577 -0.82348 16 5 -9.47021 -13.95584 -2.40553 16 6 -9.96594 -16.84825 -4.14938 16 7 -10.18661 -18.86222 -5.40384 16 8 -10.37408 NUMXQ(K)= 8 3.237E-04 0.079 1.000 2.712E-04 0.237 3.000 2.256E-04 0.395 5.000 1.714E-04 0.791 10.000 1.386E-04 1.186 15.000 1.148E-04 1.581 20.000 9.867E-05 1.976 25.000

LR-N23-0050 LAR S23-04 LAR H23-02 8.685E-05 2.372 30.000 8.049E-05 2.767 35.000 7.586E-05 3.162 40.000 6.679E-05 3.557 45.000 5.946E-05 3.953 50.000 5.341E-05 4.348 55.000 4.835E-05 4.743 60.000 4.205E-05 5.138 65.000 3.570E-05 5.534 70.000 2.060E-04 0.5 6.33 ANNUAL AVERAGE = 2.77E-06 K= 16 FIVEXQ(K)= 2.060E-04 FIVEPR(K)= 6.325

LR-N23-0050 LAR S23-04 LAR H23-02 USNRC COMPUTER CODE-PAVAN, VERSION 2.0 RUN DATE: 03-03-2023 PLANT NAME: SGS EAB METEOROLOGICAL INSTRUMENTATION DATA PERIOD: 2019-2021 WIND SENSORS HEIGHT: 10 m TYPE OF RELEASE: Ground Level DELTA-T HEIGHTS: 10 m - 46 m SOURCE OF DATA: A-5-ZZ-MDC-2391 COMMENTS: 695 m and 790 m EAB PROGRAM: PAVAN, 10/76, 8/79 REVISION, IMPLEMENTATION OF REGULATORY GUIDE 1.145 SITE EXCLUSION BOUNDARY CALCULATIONS:

DIRECTION-INDEPENDENT (S.R.P 2.3.4) MODEL.

MINIMUM BOUNDARY DISTANCE = 695.0 METERS.

BUILDING WAKE CREDIT ALLOWED: C= 0.5 A= 2399. D= 58.3 BELOW ARE PRINTED THE ORDERED VALUES OF CHI/Q AND THE FREQUENCY WITH WHICH THAT VALUE IS REACHED OR EXCEEDED.

THE TOP NUMBER IS THE CHI/Q. THE MIDDLE NUMBER IS THE FREQUENCY NORMALIZED TO THIS SECTOR.

THE THIRD NUMBER IS THE FREQUENCY WITH RESPECT TO ALL TIME.

1.714E-03 9.606E-04 8.163E-04 6.246E-04 5.530E-04 4.575E-04 4.181E-04 3.805E-04 3.099E-04 2.974E-04 0.004 0.032 0.324 0.332 1.145 1.745 2.582 2.602 3.947 4.895 0.00400 0.03202 0.32421 0.33221 1.14473 1.74512 2.58165 2.60167 3.94653 4.89513 2.810E-04 2.343E-04 2.116E-04 2.015E-04 1.812E-04 1.697E-04 1.693E-04 1.575E-04 1.523E-04 1.417E-04 6.732 8.714 9.690 12.080 12.416 12.864 12.868 17.811 22.126 22.422 6.73231 8.71358 9.69020 12.07973 12.41595 12.86423 12.86824 17.81140 22.12616 22.42235 1.227E-04 1.186E-04 1.065E-04 1.024E-04 9.511E-05 9.280E-05 8.571E-05 8.105E-05 8.063E-05 7.939E-05 23.515 25.805 26.053 36.864 37.616 39.601 39.677 39.685 39.717 40.182 23.51505 25.80452 26.05268 36.86359 37.61608 39.60135 39.67740 39.68540 39.71742 40.18172 7.711E-05 6.237E-05 6.184E-05 5.967E-05 5.714E-05 5.462E-05 5.162E-05 4.803E-05 4.697E-05 4.130E-05 48.327 53.979 58.962 59.342 59.358 59.454 61.864 61.984 67.323 67.491 48.32693 53.97855 58.96174 59.34199 59.35800 59.45406 61.86360 61.98368 67.32310 67.49120 3.880E-05 3.859E-05 3.767E-05 3.202E-05 3.144E-05 3.123E-05 2.776E-05 2.614E-05 2.363E-05 2.090E-05 69.076 69.104 73.667 73.727 77.121 77.406 78.298 78.374 81.712 82.437 69.07622 69.10423 73.66715 73.72719 77.12136 77.40554 78.29811 78.37416 81.71230 82.43676 2.082E-05 1.977E-05 1.902E-05 1.676E-05 1.399E-05 1.329E-05 1.268E-05 1.052E-05 1.001E-05 9.826E-06 82.473 82.589 83.165 83.930 84.442 84.962 85.138 85.667 86.259 86.351 82.47279 82.58886 83.16523 83.92972 84.44205 84.96238 85.13849 85.66682 86.25920 86.35126

LR-N23-0050 LAR S23-04 LAR H23-02 8.466E-06 8.025E-06 6.698E-06 6.656E-06 5.644E-06 5.034E-06 5.033E-06 4.052E-06 3.383E-06 2.702E-06 86.455 86.964 87.464 87.740 87.764 88.381 88.845 89.013 90.582 90.606 86.45532 86.96365 87.46397 87.74014 87.76416 88.38055 88.84485 89.01295 90.58196 90.60598 2.548E-06 2.043E-06 1.705E-06 1.282E-06 1.032E-06 6.878E-07 92.703 95.001 96.986 99.115 99.844 100.000 92.70332 95.00079 96.98606 99.11543 99.84389 99.99999 X/Q PERCENTILES (BASED ON THE UPPER ENVELOPE OF THE ORDERED X/Q-FREQUENCY VALUES, AND AS PLOTTED ON A LOG-NORMAL GRAPH.)

PERCENT OF TIME CHI/Q IS EQUALED OR EXCEEDED CHI/Q WITH RESPECT TO WHEN THE WIND BLOWS SEC/CUBIC METER THE TOTAL TIME INTO THIS SECTOR ONLY 5.803E-04 1.000 1.000 3.946E-04 3.000 3.000 3.205E-04 5.000 5.000 2.346E-04 10.000 10.000 1.909E-04 15.000 15.000 1.621E-04 20.000 20.000 1.398E-04 25.000 25.000 1.218E-04 30.000 30.000 1.072E-04 35.000 35.000 9.512E-05 40.000 40.000 8.482E-05 45.000 45.000 7.578E-05 50.000 50.000 6.771E-05 55.000 55.000 5.983E-05 60.000 60.000 5.082E-05 65.000 65.000 4.291E-05 70.000 70.000 3.205E-04 5.0 5.00 K= 17 FIVEXQ(K)= 3.205E-04 FIVEPR(K)= 5.000

LR-N23-0050 LAR S23-04 LAR H23-02 USNRC COMPUTER CODE-PAVAN, VERSION 2.0 RUN DATE: 03-03-2023 PLANT NAME: SGS EAB METEOROLOGICAL INSTRUMENTATION DATA PERIOD: 2019-2021 WIND SENSORS HEIGHT: 10 m TYPE OF RELEASE: Ground Level DELTA-T HEIGHTS: 10 m - 46 m SOURCE OF DATA: A-5-ZZ-MDC-2391 COMMENTS: 695 m and 790 m EAB PROGRAM: PAVAN, 10/76, 8/79 REVISION, IMPLEMENTATION OF REGULATORY GUIDE 1.145 SITE EXCLUSION BOUNDARY CALCULATIONS:

FIVE PERCENT OVERALL SITE LIMIT BUILDING WAKE CREDIT ALLOWED: C= 0.5 A= 2399. D= 58.3 BELOW ARE PRINTED THE ORDERED VALUES OF CHI/Q AND THE FREQUENCY WITH WHICH THAT VALUE IS REACHED OR EXCEEDED.

THE TOP NUMBER IS THE CHI/Q. THE MIDDLE NUMBER IS THE FREQUENCY NORMALIZED TO THIS SECTOR.

THE THIRD NUMBER IS THE FREQUENCY WITH RESPECT TO ALL TIME.

8.572E-04 5.666E-04 4.082E-04 3.329E-04 2.797E-04 2.765E-04 2.698E-04 2.465E-04 2.177E-04 2.116E-04 0.004 0.032 0.324 0.332 2.169 2.982 3.582 3.602 4.439 5.415 0.00400 0.03202 0.32421 0.33221 2.16939 2.98191 3.58229 3.60231 4.43884 5.41547 1.828E-04 1.697E-04 1.693E-04 1.585E-04 1.575E-04 1.426E-04 1.417E-04 1.186E-04 1.174E-04 1.074E-04 6.760 7.209 7.213 8.161 13.104 15.086 15.382 17.671 18.008 20.397 6.76033 7.20862 7.21262 8.16123 13.10439 15.08567 15.38186 17.67132 18.00753 20.39706 1.065E-04 9.511E-05 8.571E-05 8.323E-05 8.323E-05 8.105E-05 8.063E-05 7.951E-05 7.939E-05 7.711E-05 20.645 21.398 21.474 32.285 36.599 36.607 36.639 37.732 38.196 46.342 20.64522 21.39769 21.47374 32.28466 36.59943 36.60743 36.63944 37.73213 38.19643 46.34165 6.184E-05 6.107E-05 5.967E-05 5.714E-05 5.462E-05 5.274E-05 5.162E-05 4.803E-05 4.697E-05 4.130E-05 51.325 53.310 53.690 53.706 53.802 59.454 61.864 61.984 67.323 67.491 51.32484 53.31011 53.69035 53.70636 53.80241 59.45403 61.86357 61.98364 67.32306 67.49117 3.880E-05 3.859E-05 3.767E-05 3.202E-05 3.144E-05 3.123E-05 2.776E-05 2.614E-05 2.363E-05 2.090E-05 69.076 69.104 73.667 73.727 77.121 77.406 78.298 78.374 81.712 82.437 69.07619 69.10422 73.66714 73.72718 77.12135 77.40553 78.29810 78.37415 81.71227 82.43673 2.082E-05 1.977E-05 1.902E-05 1.676E-05 1.399E-05 1.329E-05 1.268E-05 1.052E-05 1.001E-05 9.826E-06 82.473 82.589 83.165 83.930 84.442 84.962 85.138 85.667 86.259 86.351 82.47276 82.58883 83.16520 83.92970 84.44202 84.96233 85.13845 85.66679 86.25916 86.35123

LR-N23-0050 LAR S23-04 LAR H23-02 8.466E-06 8.025E-06 6.698E-06 6.656E-06 5.644E-06 5.034E-06 5.033E-06 4.052E-06 3.383E-06 2.702E-06 86.455 86.964 87.464 87.740 87.764 88.381 88.845 89.013 90.582 90.606 86.45529 86.96360 87.46393 87.74010 87.76412 88.38050 88.84480 89.01290 90.58189 90.60591 2.548E-06 2.043E-06 1.705E-06 1.282E-06 1.032E-06 6.878E-07 92.703 95.001 96.986 99.115 99.844 100.000 92.70326 95.00072 96.98599 99.11535 99.84383 99.99992 X/Q PERCENTILES (BASED ON THE UPPER ENVELOPE OF THE ORDERED X/Q-FREQUENCY VALUES, AND AS PLOTTED ON A LOG-NORMAL GRAPH.)

PERCENT OF TIME CHI/Q IS EQUALED OR EXCEEDED CHI/Q WITH RESPECT TO WHEN THE WIND BLOWS SEC/CUBIC METER THE TOTAL TIME INTO THIS SECTOR ONLY K I XQSAVE(K,I) XQINT(K,I) XQSLOP(K,I) 18 1 -7.06188 -9.18981 -0.53950 18 2 -8.21777 -9.64393 -0.79153 18 3 -8.75619 -9.83622 -0.96299 18 4 -9.39390 -9.39390 0.00000 18 5 -9.39390 -9.49813 -0.30474 18 6 -9.47021 -9.55431 -0.91796 18 7 -9.96594 -9.42921 -1.19693 18 8 -10.18661 NUMXQ(K)= 8 3.582E-04 1.000 1.000 2.816E-04 3.000 3.000 2.384E-04 5.000 5.000 1.788E-04 10.000 10.000 1.451E-04 15.000 15.000 1.203E-04 20.000 20.000 1.024E-04 25.000 25.000 8.858E-05 30.000 30.000 8.323E-05 35.000 35.000 8.100E-05 40.000 40.000 7.791E-05 45.000 45.000 7.090E-05 50.000 50.000 6.319E-05 55.000 55.000

LR-N23-0050 LAR S23-04 LAR H23-02 5.621E-05 60.000 60.000 4.979E-05 65.000 65.000 4.291E-05 70.000 70.000 2.384E-04 5.0 5.00 K= 18 FIVEXQ(K)= 2.384E-04 FIVEPR(K)= 5.000 K HIGHPR PR GRNDVT(K) 1 -2.62223 0.43679 6.39209 2 -2.57624 0.49941 6.15594 3 -2.61747 0.44293 5.86375 4 -2.67972 0.36843 4.02257 5 -2.68524 0.36239 3.23807 6 -2.65724 0.39392 3.26609 7 -2.62495 0.43331 9.61015 8 -2.82381 0.23729 6.59222 9 -2.90888 0.18137 5.84374 10 -2.96884 0.14947 5.78770 11 -2.85344 0.21625 6.07189 12 -3.03146 0.12169 6.04387 13 -3.02370 0.12486 5.85575 14 -3.09570 0.09818 6.42811 15 -2.79414 0.26019 10.92299 16 -2.72434 0.32216 7.90506 K HOURS(K) TOTHRS 1 38.26263 38.26263 2 43.74870 82.01134 3 38.80074 120.81207 4 32.27436 153.08643 5 31.74568 184.83211 6 34.50709 219.33920 7 37.95816 257.29736 8 20.78678 278.08414 9 15.88821 293.97235 10 13.09371 307.06607 11 18.94369 326.00977 12 10.66034 336.67010 13 10.93763 347.60773 14 8.60059 356.20831

LR-N23-0050 LAR S23-04 LAR H23-02 15 22.79285 379.00116 16 28.22080 407.22195 K FIVEXQ SVANN SLTIME TIMINT I TIME XQT 1 2.324E-04 2.834E-06 -0.5255 -8.0029 1 8.0 -9.09577 2 16.0 -9.46005 3 72.0 -10.25050 4 624.0 -11.38540 2 2.435E-04 2.830E-06 -0.5313 -7.9520 1 8.0 -9.05682 2 16.0 -9.42510 3 72.0 -10.22423 4 624.0 -11.37160 3 2.293E-04 2.802E-06 -0.5253 -8.0164 1 8.0 -9.10873 2 16.0 -9.47285 3 72.0 -10.26296 4 624.0 -11.39737 4 2.085E-04 2.331E-06 -0.5359 -8.1042 1 8.0 -9.21861 2 16.0 -9.59006 3 72.0 -10.39608 4 624.0 -11.55334 5 2.038E-04 2.085E-06 -0.5465 -8.1196 1 8.0 -9.25603 2 16.0 -9.63483 3 72.0 -10.45680 4 624.0 -11.63695 6 2.145E-04 1.790E-06 -0.5708 -8.0516 1 8.0 -9.23851 2 16.0 -9.63414 3 72.0 -10.49261 4 624.0 -11.72517 7 2.307E-04 2.989E-06 -0.5183 -8.0151 1 8.0 -9.09291 2 16.0 -9.45220 3 72.0 -10.23181 4 624.0 -11.35115 8 1.823E-04 2.217E-06 -0.5259 -8.2455 1 8.0 -9.33901

LR-N23-0050 LAR S23-04 LAR H23-02 2 16.0 -9.70351 3 72.0 -10.49444 4 624.0 -11.63002 9 1.503E-04 2.048E-06 -0.5123 -8.4479 1 8.0 -9.51321 2 16.0 -9.86830 3 72.0 -10.63883 4 624.0 -11.74511 10 1.537E-04 2.269E-06 -0.5027 -8.4322 1 8.0 -9.47761 2 16.0 -9.82607 3 72.0 -10.58220 4 624.0 -11.66781 11 1.803E-04 2.507E-06 -0.5099 -8.2673 1 8.0 -9.32768 2 16.0 -9.68112 3 72.0 -10.44807 4 624.0 -11.54922 12 1.595E-04 2.211E-06 -0.5103 -8.3897 1 8.0 -9.45075 2 16.0 -9.80444 3 72.0 -10.57194 4 624.0 -11.67387 13 1.474E-04 2.000E-06 -0.5128 -8.4671 1 8.0 -9.53343 2 16.0 -9.88887 3 72.0 -10.66015 4 624.0 -11.76751 14 1.475E-04 2.066E-06 -0.5090 -8.4692 1 8.0 -9.52757 2 16.0 -9.88036 3 72.0 -10.64589 4 624.0 -11.74500 15 2.019E-04 3.301E-06 -0.4906 -8.1678 1 8.0 -9.18795 2 16.0 -9.52799 3 72.0 -10.26585 4 624.0 -11.32524 16 2.060E-04 2.771E-06 -0.5139 -8.1315 1 8.0 -9.20004 2 16.0 -9.55622

LR-N23-0050 LAR S23-04 LAR H23-02 3 72.0 -10.32910 4 624.0 -11.43876 17 3.205E-04 3.301E-06 -0.5457 -7.6675 1 8.0 -8.80224 2 16.0 -9.18048 3 72.0 -10.00123 4 624.0 -11.17963 18 2.384E-04 3.301E-06 -0.5104 -7.9879 1 8.0 -9.04924 2 16.0 -9.40302 3 72.0 -10.17069 4 624.0 -11.27287

LR-N23-0050 LAR S23-04 LAR H23-02 USNRC COMPUTER CODE-PAVAN, VERSION 2.0 RUN DATE: 03-03-2023 PLANT NAME: SGS EAB METEOROLOGICAL INSTRUMENTATION DATA PERIOD: 2019-2021 WIND SENSORS HEIGHT: 10 m TYPE OF RELEASE: Ground Level DELTA-T HEIGHTS: 10 m - 46 m SOURCE OF DATA: A-5-ZZ-MDC-2391 COMMENTS: 695 m and 790 m EAB PROGRAM: PAVAN, 10/76, 8/79 REVISION, IMPLEMENTATION OF REGULATORY GUIDE 1.145 RELATIVE CONCENTRATION (X/Q) VALUES (SEC/CUBIC METER)

VERSUS HOURS PER YEAR MAX AVERAGING TIME 0-2 HR X/Q IS DOWNWIND DISTANCE EXCEEDED DOWNWIND SECTOR (METERS) 0-2 HOURS 0-8 HOURS 8-24 HOURS 1-4 DAYS 4-30 DAYS ANNUAL AVERAGE IN SECTOR SECTOR S 695. 2.32E-04 1.12E-04 7.79E-05 3.53E-05 1.14E-05 2.83E-06 38.3 S SSW 695. 2.44E-04 1.17E-04 8.07E-05 3.63E-05 1.15E-05 2.83E-06 43.7 SSW SW 695. 2.29E-04 1.11E-04 7.69E-05 3.49E-05 1.12E-05 2.80E-06 38.8 SW WSW 695. 2.08E-04 9.92E-05 6.84E-05 3.06E-05 9.60E-06 2.33E-06 32.3 WSW W 695. 2.04E-04 9.55E-05 6.54E-05 2.88E-05 8.83E-06 2.08E-06 31.7 W WNW 695. 2.14E-04 9.72E-05 6.55E-05 2.77E-05 8.09E-06 1.79E-06 34.5 WNW NW 695. 2.31E-04 1.12E-04 7.85E-05 3.60E-05 1.18E-05 2.99E-06 38.0 NW NNW 695. 1.82E-04 8.79E-05 6.11E-05 2.77E-05 8.89E-06 2.22E-06 20.8 NNW N 695. 1.50E-04 7.39E-05 5.18E-05 2.40E-05 7.93E-06 2.05E-06 15.9 N NNE 695. 1.54E-04 7.65E-05 5.40E-05 2.54E-05 8.57E-06 2.27E-06 13.1 NNE NE 695. 1.80E-04 8.89E-05 6.25E-05 2.90E-05 9.64E-06 2.51E-06 18.9 NE ENE 695. 1.60E-04 7.86E-05 5.52E-05 2.56E-05 8.51E-06 2.21E-06 10.7 ENE E 695. 1.47E-04 7.24E-05 5.07E-05 2.35E-05 7.75E-06 2.00E-06 10.9 E ESE 695. 1.47E-04 7.28E-05 5.12E-05 2.38E-05 7.93E-06 2.07E-06 8.6 ESE SE 695. 2.02E-04 1.02E-04 7.28E-05 3.48E-05 1.21E-05 3.30E-06 22.8 SE SSE 695. 2.06E-04 1.01E-04 7.08E-05 3.27E-05 1.08E-05 2.77E-06 28.2 SSE MAX X/Q 2.44E-04 TOTAL HOURS AROUND SITE: 407.2 SRP 2.3.4 695. 3.20E-04 1.50E-04 1.03E-04 4.53E-05 1.40E-05 3.30E-06 SITE LIMIT 2.38E-04 1.17E-04 8.25E-05 3.83E-05 1.27E-05 3.30E-06 0.5 PERCENT X/Q TO AN INDIVIDUAL IS LIMITING.

    • NOTE**: VALUES ON THIS PAGE ARE APPROXIMATIONS ONLY.

CHECK THE REASONABLENESS OF THE ENVELOPES COMPUTED FOR THE 0-2 HOUR VALUES. FOR ANY FAULTY ENVELOPES, ADJUST THE ABOVE VALUES.

LR-N23-0050 LAR S23-04 LAR H23-02 USNRC COMPUTER CODE-PAVAN, VERSION 2.0 RUN DATE: 03-03-2023 PLANT NAME: SGS EAB METEOROLOGICAL INSTRUMENTATION DATA PERIOD: 2019-2021 WIND SENSORS HEIGHT: 10 m TYPE OF RELEASE: Ground Level DELTA-T HEIGHTS: 10 m - 46 m SOURCE OF DATA: A-5-ZZ-MDC-2391 COMMENTS: 695 m and 790 m EAB PROGRAM: PAVAN, 10/76, 8/79 REVISION, IMPLEMENTATION OF REGULATORY GUIDE 1.145 LOW POPULATION ZONE CALCULATIONS:

S SECTOR BOUNDARY DISTANCE = 790.0 METERS LATERAL PLUME MEANDER/BUILDING WAKE CREDIT ALLOWED AS A FUNCTION OF DOWNWIND DISTANCE.

MEANDER CREDIT IS FOR WINDSPEEDS LESS THAN 6 MPS.

BUILDING WAKE CREDIT ALLOWED: C= 0.5 A= 2399. D= 58.3 BELOW ARE PRINTED THE ORDERED VALUES OF CHI/Q AND THE FREQUENCY WITH WHICH THAT VALUE IS REACHED OR EXCEEDED.

THE TOP NUMBER IS THE CHI/Q. THE MIDDLE NUMBER IS THE FREQUENCY NORMALIZED TO THIS SECTOR.

THE THIRD NUMBER IS THE FREQUENCY WITH RESPECT TO ALL TIME.

3.282E-04 2.249E-04 2.224E-04 2.179E-04 1.750E-04 1.702E-04 1.476E-04 1.365E-04 1.286E-04 1.278E-04 0.125 3.757 4.446 5.072 6.011 9.267 10.958 11.522 12.837 22.041 0.00801 0.24015 0.28418 0.32421 0.38425 0.59238 0.70045 0.73647 0.82053 1.40890 1.152E-04 1.139E-04 1.077E-04 9.468E-05 8.713E-05 8.640E-05 7.212E-05 6.753E-05 6.753E-05 6.732E-05 24.233 24.296 28.366 28.867 31.622 32.624 33.939 42.893 46.900 54.164 1.54899 1.55299 1.81316 1.84518 2.02129 2.08533 2.16939 2.74175 2.99792 3.46222 6.414E-05 5.420E-05 5.399E-05 4.926E-05 4.507E-05 4.422E-05 4.254E-05 3.831E-05 3.387E-05 3.344E-05 54.978 55.103 61.052 63.118 64.621 64.809 70.131 75.141 75.830 75.955 3.51425 3.52225 3.90250 4.03458 4.13064 4.14265 4.48287 4.80307 4.84710 4.85511 3.179E-05 2.727E-05 2.653E-05 2.247E-05 1.994E-05 1.693E-05 1.605E-05 1.357E-05 1.133E-05 1.039E-05 79.900 80.025 82.718 83.719 85.348 85.911 86.036 87.101 87.289 87.915 5.10727 5.11527 5.28738 5.35142 5.45549 5.49151 5.49952 5.56756 5.57957 5.61960 8.515E-06 7.826E-06 6.855E-06 6.277E-06 5.239E-06 4.683E-06 3.937E-06 3.541E-06 3.170E-06 2.380E-06 88.228 88.478 88.541 89.292 89.543 89.793 90.044 90.357 90.420 91.797 5.63961 5.65562 5.65962 5.70765 5.72366 5.73967 5.75568 5.77570 5.77970 5.86776

LR-N23-0050 LAR S23-04 LAR H23-02 1.792E-06 1.437E-06 1.200E-06 9.017E-07 7.259E-07 93.550 95.993 97.558 99.624 100.000 5.97983 6.13593 6.23599 6.36808 6.39209 X/Q PERCENTILES (BASED ON THE UPPER ENVELOPE OF THE ORDERED X/Q-FREQUENCY VALUES, AND AS PLOTTED ON A LOG-NORMAL GRAPH.)

PERCENT OF TIME CHI/Q IS EQUALED OR EXCEEDED CHI/Q WITH RESPECT TO WHEN THE WIND BLOWS SEC/CUBIC METER THE TOTAL TIME INTO THIS SECTOR ONLY HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 4)=

1.407 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 5)=

1.811 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 6)=

3.459 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 7)=

4.799 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 8)=

5.104 K I XQSAVE(K,I) XQINT(K,I) XQSLOP(K,I) 1 1 -8.02175 -9.47873 -0.38596 1 2 -8.41121 -9.69444 -0.46395 1 3 -8.43128 -11.18738 -1.01230 1 4 -8.96514 -12.68228 -1.69327 1 5 -9.13588 -12.68819 -1.69609 1 6 -9.60600 -16.31927 -3.69423 1 7 -10.16978 -20.62025 -6.27800 1 8 -10.35639 NUMXQ(K)= 8 2.651E-04 0.064 1.000 2.334E-04 0.192 3.000 2.184E-04 0.320 5.000 1.722E-04 0.639 10.000 1.483E-04 0.959 15.000 1.328E-04 1.278 20.000 1.174E-04 1.598 25.000

LR-N23-0050 LAR S23-04 LAR H23-02 1.036E-04 1.918 30.000 9.296E-05 2.237 35.000 8.444E-05 2.557 40.000 7.743E-05 2.876 45.000 7.155E-05 3.196 50.000 6.562E-05 3.516 55.000 5.666E-05 3.835 60.000 4.939E-05 4.155 65.000 4.341E-05 4.474 70.000 3.844E-05 4.794 75.000 1.879E-04 0.5 7.82 ANNUAL AVERAGE = 2.32E-06 K= 1 FIVEXQ(K)= 1.879E-04 FIVEPR(K)= 7.822

LR-N23-0050 LAR S23-04 LAR H23-02 USNRC COMPUTER CODE-PAVAN, VERSION 2.0 RUN DATE: 03-03-2023 PLANT NAME: SGS EAB METEOROLOGICAL INSTRUMENTATION DATA PERIOD: 2019-2021 WIND SENSORS HEIGHT: 10 m TYPE OF RELEASE: Ground Level DELTA-T HEIGHTS: 10 m - 46 m SOURCE OF DATA: A-5-ZZ-MDC-2391 COMMENTS: 695 m and 790 m EAB PROGRAM: PAVAN, 10/76, 8/79 REVISION, IMPLEMENTATION OF REGULATORY GUIDE 1.145 LOW POPULATION ZONE CALCULATIONS:

SSW SECTOR BOUNDARY DISTANCE = 790.0 METERS LATERAL PLUME MEANDER/BUILDING WAKE CREDIT ALLOWED AS A FUNCTION OF DOWNWIND DISTANCE.

MEANDER CREDIT IS FOR WINDSPEEDS LESS THAN 6 MPS.

BUILDING WAKE CREDIT ALLOWED: C= 0.5 A= 2399. D= 58.3 BELOW ARE PRINTED THE ORDERED VALUES OF CHI/Q AND THE FREQUENCY WITH WHICH THAT VALUE IS REACHED OR EXCEEDED.

THE TOP NUMBER IS THE CHI/Q. THE MIDDLE NUMBER IS THE FREQUENCY NORMALIZED TO THIS SECTOR.

THE THIRD NUMBER IS THE FREQUENCY WITH RESPECT TO ALL TIME.

3.282E-04 2.249E-04 2.224E-04 2.179E-04 1.988E-04 1.750E-04 1.702E-04 1.476E-04 1.371E-04 1.365E-04 0.260 4.096 5.462 6.437 6.502 8.257 10.338 11.834 11.899 12.159 0.01601 0.25216 0.33622 0.39625 0.40026 0.50833 0.63641 0.72847 0.73247 0.74848 1.286E-04 1.278E-04 1.152E-04 1.139E-04 1.077E-04 9.468E-05 8.713E-05 8.640E-05 7.212E-05 6.753E-05 13.069 20.481 22.692 22.757 25.813 26.463 29.194 29.779 29.844 40.377 0.80451 1.26081 1.39689 1.40090 1.58902 1.62904 1.79715 1.83317 1.83718 2.48559 6.753E-05 6.732E-05 6.528E-05 6.414E-05 5.420E-05 5.399E-05 4.926E-05 4.507E-05 4.422E-05 4.254E-05 43.953 50.715 50.780 51.886 51.951 54.876 57.152 58.192 58.257 65.020 2.70573 3.12200 3.12600 3.19404 3.19805 3.37816 3.51825 3.58229 3.58629 4.00256 3.831E-05 3.387E-05 3.344E-05 3.179E-05 2.727E-05 2.653E-05 2.247E-05 2.045E-05 1.994E-05 1.693E-05 71.066 71.651 71.847 76.918 76.983 81.079 81.664 81.795 83.615 84.330 4.37480 4.41082 4.42283 4.73503 4.73903 4.99119 5.02722 5.03522 5.14729 5.19132 1.605E-05 1.357E-05 1.133E-05 1.039E-05 8.515E-06 7.826E-06 6.913E-06 6.277E-06 5.239E-06 4.683E-06 84.395 85.436 86.411 86.931 87.321 87.971 88.101 89.077 89.792 90.052 5.19532 5.25937 5.31940 5.35142 5.37544 5.41547 5.42347 5.48351 5.52754 5.54355

LR-N23-0050 LAR S23-04 LAR H23-02 3.937E-06 3.541E-06 2.380E-06 1.792E-06 1.437E-06 1.200E-06 9.017E-07 7.259E-07 90.572 91.027 92.588 95.124 97.334 98.830 99.935 100.000 5.57557 5.60359 5.69965 5.85575 5.99183 6.08389 6.15194 6.15594 X/Q PERCENTILES (BASED ON THE UPPER ENVELOPE OF THE ORDERED X/Q-FREQUENCY VALUES, AND AS PLOTTED ON A LOG-NORMAL GRAPH.)

PERCENT OF TIME CHI/Q IS EQUALED OR EXCEEDED CHI/Q WITH RESPECT TO WHEN THE WIND BLOWS SEC/CUBIC METER THE TOTAL TIME INTO THIS SECTOR ONLY HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 3)=

1.259 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 4)=

1.587 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 5)=

3.119 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 6)=

4.371 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 7)=

4.731 K I XQSAVE(K,I) XQINT(K,I) XQSLOP(K,I) 2 1 -8.02175 -9.58472 -0.43434 2 2 -8.43128 -11.83016 -1.27987 2 3 -8.96514 -13.16934 -1.87812 2 4 -9.13588 -12.69052 -1.65516 2 5 -9.60600 -16.40892 -3.65047 2 6 -10.16978 -18.63831 -4.95486 2 7 -10.35639 NUMXQ(K)= 7 2.799E-04 0.062 1.000 2.427E-04 0.185 3.000 2.260E-04 0.308 5.000 1.794E-04 0.616 10.000 1.486E-04 0.923 15.000 1.293E-04 1.231 20.000 1.103E-04 1.539 25.000 9.743E-05 1.847 30.000

LR-N23-0050 LAR S23-04 LAR H23-02 8.769E-05 2.155 35.000 7.988E-05 2.462 40.000 7.344E-05 2.770 45.000 6.803E-05 3.078 50.000 5.897E-05 3.386 55.000 5.106E-05 3.694 60.000 4.462E-05 4.001 65.000 3.932E-05 4.309 70.000 3.375E-05 4.617 75.000 1.969E-04 0.5 8.12 ANNUAL AVERAGE = 2.31E-06 K= 2 FIVEXQ(K)= 1.969E-04 FIVEPR(K)= 8.122

LR-N23-0050 LAR S23-04 LAR H23-02 USNRC COMPUTER CODE-PAVAN, VERSION 2.0 RUN DATE: 03-03-2023 PLANT NAME: SGS EAB METEOROLOGICAL INSTRUMENTATION DATA PERIOD: 2019-2021 WIND SENSORS HEIGHT: 10 m TYPE OF RELEASE: Ground Level DELTA-T HEIGHTS: 10 m - 46 m SOURCE OF DATA: A-5-ZZ-MDC-2391 COMMENTS: 695 m and 790 m EAB PROGRAM: PAVAN, 10/76, 8/79 REVISION, IMPLEMENTATION OF REGULATORY GUIDE 1.145 LOW POPULATION ZONE CALCULATIONS:

SW SECTOR BOUNDARY DISTANCE = 790.0 METERS LATERAL PLUME MEANDER/BUILDING WAKE CREDIT ALLOWED AS A FUNCTION OF DOWNWIND DISTANCE.

MEANDER CREDIT IS FOR WINDSPEEDS LESS THAN 6 MPS.

BUILDING WAKE CREDIT ALLOWED: C= 0.5 A= 2399. D= 58.3 BELOW ARE PRINTED THE ORDERED VALUES OF CHI/Q AND THE FREQUENCY WITH WHICH THAT VALUE IS REACHED OR EXCEEDED.

THE TOP NUMBER IS THE CHI/Q. THE MIDDLE NUMBER IS THE FREQUENCY NORMALIZED TO THIS SECTOR.

THE THIRD NUMBER IS THE FREQUENCY WITH RESPECT TO ALL TIME.

3.282E-04 2.249E-04 2.224E-04 2.179E-04 1.988E-04 1.750E-04 1.702E-04 1.476E-04 1.365E-04 1.286E-04 0.751 4.027 5.188 6.143 6.212 7.509 8.191 10.239 10.375 11.809 0.04403 0.23615 0.30419 0.36023 0.36423 0.44028 0.48031 0.60038 0.60839 0.69244 1.278E-04 1.152E-04 1.077E-04 9.468E-05 8.713E-05 8.640E-05 6.753E-05 6.753E-05 6.732E-05 6.528E-05 17.270 20.819 22.526 22.799 25.529 25.597 35.563 41.229 45.939 46.007 1.01265 1.22078 1.32085 1.33686 1.49696 1.50096 2.08533 2.41755 2.69372 2.69773 6.414E-05 5.399E-05 4.926E-05 4.507E-05 4.422E-05 4.363E-05 4.254E-05 3.831E-05 3.387E-05 3.344E-05 48.532 51.058 54.676 55.768 56.041 56.109 66.553 72.765 72.833 73.038 2.84582 2.99392 3.20605 3.27009 3.28610 3.29011 3.90250 4.26673 4.27073 4.28274 3.179E-05 2.653E-05 2.247E-05 2.045E-05 1.994E-05 1.693E-05 1.605E-05 1.546E-05 1.357E-05 1.133E-05 77.406 79.317 80.751 81.024 82.116 83.140 83.276 83.481 84.232 84.369 4.53890 4.65098 4.73503 4.75104 4.81508 4.87512 4.88312 4.89513 4.93916 4.94717 1.039E-05 8.515E-06 7.826E-06 6.277E-06 5.239E-06 4.683E-06 3.937E-06 3.541E-06 2.380E-06 1.792E-06 85.119 85.256 85.734 86.075 86.485 86.962 87.235 88.532 91.945 96.997 4.99119 4.99920 5.02722 5.04723 5.07125 5.09926 5.11527 5.19132 5.39145 5.68764

LR-N23-0050 LAR S23-04 LAR H23-02 1.437E-06 1.200E-06 9.017E-07 98.567 99.590 100.000 5.77970 5.83974 5.86375 X/Q PERCENTILES (BASED ON THE UPPER ENVELOPE OF THE ORDERED X/Q-FREQUENCY VALUES, AND AS PLOTTED ON A LOG-NORMAL GRAPH.)

PERCENT OF TIME CHI/Q IS EQUALED OR EXCEEDED CHI/Q WITH RESPECT TO WHEN THE WIND BLOWS SEC/CUBIC METER THE TOTAL TIME INTO THIS SECTOR ONLY HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 3)=

1.011 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 4)=

1.219 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 5)=

2.691 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 6)=

2.843 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 7)=

4.263 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 8)=

4.535 K I XQSAVE(K,I) XQINT(K,I) XQSLOP(K,I) 3 1 -8.02175 -10.15445 -0.64115 3 2 -8.43128 -12.35630 -1.46041 3 3 -8.96514 -12.36349 -1.46350 3 4 -9.06919 -12.81369 -1.66351 3 5 -9.60600 -13.52055 -2.03008 3 6 -9.65451 -15.00328 -2.80868 3 7 -10.16978 -21.15276 -6.38204 3 8 -10.35639 NUMXQ(K)= 8 3.117E-04 0.059 1.000 2.528E-04 0.176 3.000 2.277E-04 0.293 5.000 1.708E-04 0.586 10.000 1.380E-04 0.880 15.000

LR-N23-0050 LAR S23-04 LAR H23-02 1.178E-04 1.173 20.000 1.023E-04 1.466 25.000 9.059E-05 1.759 30.000 8.155E-05 2.052 35.000 7.430E-05 2.346 40.000 6.833E-05 2.639 45.000 6.183E-05 2.932 50.000 5.491E-05 3.225 55.000 4.920E-05 3.518 60.000 4.439E-05 3.811 65.000 4.031E-05 4.105 70.000 3.498E-05 4.398 75.000 1.852E-04 0.5 8.53 ANNUAL AVERAGE = 2.29E-06 K= 3 FIVEXQ(K)= 1.852E-04 FIVEPR(K)= 8.527

LR-N23-0050 LAR S23-04 LAR H23-02 USNRC COMPUTER CODE-PAVAN, VERSION 2.0 RUN DATE: 03-03-2023 PLANT NAME: SGS EAB METEOROLOGICAL INSTRUMENTATION DATA PERIOD: 2019-2021 WIND SENSORS HEIGHT: 10 m TYPE OF RELEASE: Ground Level DELTA-T HEIGHTS: 10 m - 46 m SOURCE OF DATA: A-5-ZZ-MDC-2391 COMMENTS: 695 m and 790 m EAB PROGRAM: PAVAN, 10/76, 8/79 REVISION, IMPLEMENTATION OF REGULATORY GUIDE 1.145 LOW POPULATION ZONE CALCULATIONS:

WSW SECTOR BOUNDARY DISTANCE = 790.0 METERS LATERAL PLUME MEANDER/BUILDING WAKE CREDIT ALLOWED AS A FUNCTION OF DOWNWIND DISTANCE.

MEANDER CREDIT IS FOR WINDSPEEDS LESS THAN 6 MPS.

BUILDING WAKE CREDIT ALLOWED: C= 0.5 A= 2399. D= 58.3 BELOW ARE PRINTED THE ORDERED VALUES OF CHI/Q AND THE FREQUENCY WITH WHICH THAT VALUE IS REACHED OR EXCEEDED.

THE TOP NUMBER IS THE CHI/Q. THE MIDDLE NUMBER IS THE FREQUENCY NORMALIZED TO THIS SECTOR.

THE THIRD NUMBER IS THE FREQUENCY WITH RESPECT TO ALL TIME.

4.577E-04 3.282E-04 2.249E-04 2.224E-04 2.179E-04 1.750E-04 1.702E-04 1.476E-04 1.286E-04 1.278E-04 0.199 1.393 3.184 6.269 7.463 9.353 9.652 14.229 16.915 20.995 0.00801 0.05604 0.12808 0.25216 0.30019 0.37624 0.38825 0.57237 0.68044 0.84454 1.152E-04 1.077E-04 9.468E-05 8.713E-05 8.640E-05 6.753E-05 6.753E-05 6.732E-05 6.414E-05 5.399E-05 24.279 24.677 25.572 30.050 30.249 40.100 47.761 50.945 53.731 54.826 0.97663 0.99264 1.02866 1.20877 1.21678 1.61303 1.92123 2.04931 2.16138 2.20541 4.926E-05 4.507E-05 4.422E-05 4.254E-05 3.831E-05 3.387E-05 3.344E-05 3.179E-05 3.019E-05 2.653E-05 59.502 60.099 60.199 67.861 71.841 71.940 72.637 75.124 75.224 76.119 2.39353 2.41755 2.42155 2.72975 2.88985 2.89385 2.92187 3.02193 3.02594 3.06196 2.247E-05 2.045E-05 1.994E-05 1.693E-05 1.546E-05 1.357E-05 1.133E-05 1.039E-05 8.515E-06 7.826E-06 78.109 78.507 78.706 80.100 80.398 80.498 80.697 81.891 81.990 82.786 3.14201 3.15802 3.16603 3.22206 3.23407 3.23807 3.24608 3.29411 3.29811 3.33013 6.913E-06 6.277E-06 5.239E-06 4.683E-06 3.937E-06 3.541E-06 2.380E-06 1.792E-06 1.437E-06 1.200E-06 82.985 83.582 83.682 84.776 85.174 86.766 91.144 94.826 97.313 98.507 3.33814 3.36215 3.36615 3.41018 3.42619 3.49023 3.66635 3.81444 3.91451 3.96254

LR-N23-0050 LAR S23-04 LAR H23-02 9.017E-07 100.000 4.02258 X/Q PERCENTILES (BASED ON THE UPPER ENVELOPE OF THE ORDERED X/Q-FREQUENCY VALUES, AND AS PLOTTED ON A LOG-NORMAL GRAPH.)

PERCENT OF TIME CHI/Q IS EQUALED OR EXCEEDED CHI/Q WITH RESPECT TO WHEN THE WIND BLOWS SEC/CUBIC METER THE TOTAL TIME INTO THIS SECTOR ONLY HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 4)=

0.844 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 5)=

2.047 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 6)=

2.159 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 7)=

2.727 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 8)=

2.887 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 9)=

3.019 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE(10)=

3.139 K I XQSAVE(K,I) XQINT(K,I) XQSLOP(K,I) 4 1 -7.68934 -10.11939 -0.64373 4 2 -8.02175 -10.63519 -0.80202 4 3 -8.43128 -12.52410 -1.48941 4 4 -8.96514 -13.39867 -1.85542 4 5 -9.60600 -14.07931 -2.18839 4 6 -9.65451 -18.00420 -4.12954 4 7 -10.06511 -18.16101 -4.21111 4 8 -10.16978 -28.18362 -9.49268 4 9 -10.35639 -48.07991 -20.08709 4 10 -10.70314 NUMXQ(K)= 10 3.485E-04 0.040 1.000

LR-N23-0050 LAR S23-04 LAR H23-02 2.742E-04 0.121 3.000 2.417E-04 0.201 5.000 1.885E-04 0.402 10.000 1.530E-04 0.603 15.000 1.312E-04 0.805 20.000 1.133E-04 1.006 25.000 9.964E-05 1.207 30.000 8.916E-05 1.408 35.000 8.082E-05 1.609 40.000 7.400E-05 1.810 45.000 6.830E-05 2.011 50.000 6.160E-05 2.212 55.000 5.292E-05 2.414 60.000 4.594E-05 2.615 65.000 4.019E-05 2.816 70.000 3.201E-05 3.017 75.000 1.688E-04 0.5 12.43 ANNUAL AVERAGE = 1.90E-06 K= 4 FIVEXQ(K)= 1.688E-04 FIVEPR(K)=12.430

LR-N23-0050 LAR S23-04 LAR H23-02 USNRC COMPUTER CODE-PAVAN, VERSION 2.0 RUN DATE: 03-03-2023 PLANT NAME: SGS EAB METEOROLOGICAL INSTRUMENTATION DATA PERIOD: 2019-2021 WIND SENSORS HEIGHT: 10 m TYPE OF RELEASE: Ground Level DELTA-T HEIGHTS: 10 m - 46 m SOURCE OF DATA: A-5-ZZ-MDC-2391 COMMENTS: 695 m and 790 m EAB PROGRAM: PAVAN, 10/76, 8/79 REVISION, IMPLEMENTATION OF REGULATORY GUIDE 1.145 LOW POPULATION ZONE CALCULATIONS:

W SECTOR BOUNDARY DISTANCE = 790.0 METERS LATERAL PLUME MEANDER/BUILDING WAKE CREDIT ALLOWED AS A FUNCTION OF DOWNWIND DISTANCE.

MEANDER CREDIT IS FOR WINDSPEEDS LESS THAN 6 MPS.

BUILDING WAKE CREDIT ALLOWED: C= 0.5 A= 2399. D= 58.3 BELOW ARE PRINTED THE ORDERED VALUES OF CHI/Q AND THE FREQUENCY WITH WHICH THAT VALUE IS REACHED OR EXCEEDED.

THE TOP NUMBER IS THE CHI/Q. THE MIDDLE NUMBER IS THE FREQUENCY NORMALIZED TO THIS SECTOR.

THE THIRD NUMBER IS THE FREQUENCY WITH RESPECT TO ALL TIME.

4.577E-04 3.282E-04 2.249E-04 2.224E-04 2.179E-04 1.988E-04 1.750E-04 1.476E-04 1.286E-04 1.278E-04 0.124 0.989 3.461 7.664 9.271 9.394 12.237 16.811 18.912 22.868 0.00400 0.03202 0.11207 0.24816 0.30019 0.30419 0.39625 0.54435 0.61239 0.74047 1.152E-04 1.077E-04 9.468E-05 8.713E-05 6.753E-05 6.753E-05 6.732E-05 6.414E-05 5.399E-05 4.926E-05 28.430 28.801 29.666 35.970 48.208 57.602 61.187 63.906 64.400 68.356 0.92059 0.93260 0.96061 1.16475 1.56100 1.86519 1.98127 2.06932 2.08533 2.21342 4.507E-05 4.422E-05 4.254E-05 3.831E-05 3.344E-05 3.179E-05 2.653E-05 2.247E-05 2.045E-05 1.994E-05 68.603 69.221 75.525 79.110 79.728 81.459 81.706 82.818 83.189 83.560 2.22142 2.24143 2.44556 2.56164 2.58165 2.63769 2.64569 2.68172 2.69372 2.70573 1.693E-05 1.546E-05 1.357E-05 1.070E-05 1.039E-05 7.826E-06 6.913E-06 4.683E-06 3.541E-06 2.380E-06 84.549 84.920 85.167 85.290 86.279 86.650 86.774 87.145 88.504 93.078 2.73775 2.74976 2.75776 2.76177 2.79379 2.80580 2.80980 2.82181 2.86583 3.01393 1.792E-06 1.437E-06 1.200E-06 9.017E-07 96.415 98.640 99.506 100.000 3.12200 3.19404 3.22206 3.23807

LR-N23-0050 LAR S23-04 LAR H23-02 X/Q PERCENTILES (BASED ON THE UPPER ENVELOPE OF THE ORDERED X/Q-FREQUENCY VALUES, AND AS PLOTTED ON A LOG-NORMAL GRAPH.)

PERCENT OF TIME CHI/Q IS EQUALED OR EXCEEDED CHI/Q WITH RESPECT TO WHEN THE WIND BLOWS SEC/CUBIC METER THE TOTAL TIME INTO THIS SECTOR ONLY HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 3)=

0.920 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 4)=

1.979 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 5)=

2.067 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 6)=

2.559 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 7)=

2.635 K I XQSAVE(K,I) XQINT(K,I) XQSLOP(K,I) 5 1 -7.68934 -10.13548 -0.62017 5 2 -8.43128 -12.92281 -1.63450 5 3 -9.06919 -13.29363 -1.79179 5 4 -9.60600 -15.15334 -2.69540 5 5 -9.65451 -21.31856 -5.71746 5 6 -10.16978 -39.06004 -14.81587 5 7 -10.35639 NUMXQ(K)= 7 3.288E-04 0.032 1.000 2.710E-04 0.097 3.000 2.462E-04 0.162 5.000 2.092E-04 0.324 10.000 1.673E-04 0.486 15.000 1.419E-04 0.648 20.000 1.244E-04 0.810 25.000 1.111E-04 0.971 30.000 1.001E-04 1.133 35.000 9.130E-05 1.295 40.000 8.406E-05 1.457 45.000 7.799E-05 1.619 50.000

LR-N23-0050 LAR S23-04 LAR H23-02 7.280E-05 1.781 55.000 6.830E-05 1.943 60.000 6.160E-05 2.105 65.000 5.158E-05 2.267 70.000 4.365E-05 2.429 75.000 3.568E-05 2.590 80.000 1.646E-04 0.5 15.44 ANNUAL AVERAGE = 1.70E-06 K= 5 FIVEXQ(K)= 1.646E-04 FIVEPR(K)=15.441

LR-N23-0050 LAR S23-04 LAR H23-02 USNRC COMPUTER CODE-PAVAN, VERSION 2.0 RUN DATE: 03-03-2023 PLANT NAME: SGS EAB METEOROLOGICAL INSTRUMENTATION DATA PERIOD: 2019-2021 WIND SENSORS HEIGHT: 10 m TYPE OF RELEASE: Ground Level DELTA-T HEIGHTS: 10 m - 46 m SOURCE OF DATA: A-5-ZZ-MDC-2391 COMMENTS: 695 m and 790 m EAB PROGRAM: PAVAN, 10/76, 8/79 REVISION, IMPLEMENTATION OF REGULATORY GUIDE 1.145 LOW POPULATION ZONE CALCULATIONS:

WNW SECTOR BOUNDARY DISTANCE = 790.0 METERS LATERAL PLUME MEANDER/BUILDING WAKE CREDIT ALLOWED AS A FUNCTION OF DOWNWIND DISTANCE.

MEANDER CREDIT IS FOR WINDSPEEDS LESS THAN 6 MPS.

BUILDING WAKE CREDIT ALLOWED: C= 0.5 A= 2399. D= 58.3 BELOW ARE PRINTED THE ORDERED VALUES OF CHI/Q AND THE FREQUENCY WITH WHICH THAT VALUE IS REACHED OR EXCEEDED.

THE TOP NUMBER IS THE CHI/Q. THE MIDDLE NUMBER IS THE FREQUENCY NORMALIZED TO THIS SECTOR.

THE THIRD NUMBER IS THE FREQUENCY WITH RESPECT TO ALL TIME.

3.282E-04 2.249E-04 2.224E-04 2.179E-04 1.750E-04 1.702E-04 1.476E-04 1.286E-04 1.278E-04 1.152E-04 0.613 6.863 8.701 9.926 12.745 13.113 14.706 15.931 26.593 29.657 0.02001 0.22414 0.28418 0.32421 0.41627 0.42827 0.48031 0.52033 0.86856 0.96862 1.077E-04 9.468E-05 8.713E-05 8.640E-05 6.753E-05 6.753E-05 6.732E-05 6.414E-05 5.399E-05 4.926E-05 31.863 32.598 36.275 36.397 49.020 54.412 64.583 65.686 68.137 70.956 1.04067 1.06468 1.18476 1.18876 1.60102 1.77714 2.10935 2.14537 2.22542 2.31748 4.507E-05 4.254E-05 3.831E-05 3.344E-05 3.179E-05 3.019E-05 2.653E-05 2.247E-05 1.994E-05 1.693E-05 71.691 77.206 80.760 81.127 83.578 83.824 84.191 85.172 85.662 86.520 2.34150 2.52161 2.63769 2.64970 2.72975 2.73775 2.74976 2.78178 2.79779 2.82581 1.605E-05 1.546E-05 1.357E-05 1.133E-05 1.039E-05 8.515E-06 7.826E-06 6.913E-06 6.277E-06 5.239E-06 86.887 87.010 87.745 87.868 88.113 88.358 89.338 89.583 90.074 90.319 2.83782 2.84182 2.86583 2.86984 2.87784 2.88585 2.91787 2.92587 2.94188 2.94989 4.683E-06 3.937E-06 3.541E-06 2.380E-06 1.792E-06 1.437E-06 1.200E-06 9.017E-07 90.686 91.176 91.789 94.118 95.833 97.549 98.652 100.000 2.96189 2.97791 2.99792 3.07397 3.13000 3.18604 3.22206 3.26609

LR-N23-0050 LAR S23-04 LAR H23-02 X/Q PERCENTILES (BASED ON THE UPPER ENVELOPE OF THE ORDERED X/Q-FREQUENCY VALUES, AND AS PLOTTED ON A LOG-NORMAL GRAPH.)

PERCENT OF TIME CHI/Q IS EQUALED OR EXCEEDED CHI/Q WITH RESPECT TO WHEN THE WIND BLOWS SEC/CUBIC METER THE TOTAL TIME INTO THIS SECTOR ONLY HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 3)=

0.868 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 4)=

2.107 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 5)=

2.635 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 6)=

2.727 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 7)=

2.863 K I XQSAVE(K,I) XQINT(K,I) XQSLOP(K,I) 6 1 -8.02175 -9.79526 -0.50098 6 2 -8.43128 -12.66362 -1.55451 6 3 -8.96514 -13.35814 -1.84643 6 4 -9.60600 -21.69734 -5.95014 6 5 -10.16978 -34.51957 -12.56855 6 6 -10.35639 -87.52495 -40.13945 6 7 -11.20739 NUMXQ(K)= 7 3.073E-04 0.033 1.000 2.628E-04 0.098 3.000 2.432E-04 0.163 5.000 2.171E-04 0.327 10.000 1.755E-04 0.490 15.000 1.500E-04 0.653 20.000 1.324E-04 0.817 25.000 1.176E-04 0.980 30.000 1.057E-04 1.143 35.000 9.608E-05 1.306 40.000 8.823E-05 1.470 45.000 8.166E-05 1.633 50.000

LR-N23-0050 LAR S23-04 LAR H23-02 7.606E-05 1.796 55.000 7.122E-05 1.960 60.000 6.626E-05 2.123 65.000 5.507E-05 2.286 70.000 4.627E-05 2.450 75.000 3.925E-05 2.613 80.000 2.369E-05 2.776 85.000 1.736E-04 0.5 15.31 ANNUAL AVERAGE = 1.46E-06 K= 6 FIVEXQ(K)= 1.736E-04 FIVEPR(K)=15.309

LR-N23-0050 LAR S23-04 LAR H23-02 USNRC COMPUTER CODE-PAVAN, VERSION 2.0 RUN DATE: 03-03-2023 PLANT NAME: SGS EAB METEOROLOGICAL INSTRUMENTATION DATA PERIOD: 2019-2021 WIND SENSORS HEIGHT: 10 m TYPE OF RELEASE: Ground Level DELTA-T HEIGHTS: 10 m - 46 m SOURCE OF DATA: A-5-ZZ-MDC-2391 COMMENTS: 695 m and 790 m EAB PROGRAM: PAVAN, 10/76, 8/79 REVISION, IMPLEMENTATION OF REGULATORY GUIDE 1.145 LOW POPULATION ZONE CALCULATIONS:

NW SECTOR BOUNDARY DISTANCE = 790.0 METERS LATERAL PLUME MEANDER/BUILDING WAKE CREDIT ALLOWED AS A FUNCTION OF DOWNWIND DISTANCE.

MEANDER CREDIT IS FOR WINDSPEEDS LESS THAN 6 MPS.

BUILDING WAKE CREDIT ALLOWED: C= 0.5 A= 2399. D= 58.3 BELOW ARE PRINTED THE ORDERED VALUES OF CHI/Q AND THE FREQUENCY WITH WHICH THAT VALUE IS REACHED OR EXCEEDED.

THE TOP NUMBER IS THE CHI/Q. THE MIDDLE NUMBER IS THE FREQUENCY NORMALIZED TO THIS SECTOR.

THE THIRD NUMBER IS THE FREQUENCY WITH RESPECT TO ALL TIME.

4.577E-04 3.282E-04 2.249E-04 2.224E-04 2.179E-04 1.750E-04 1.702E-04 1.476E-04 1.365E-04 1.286E-04 0.083 0.208 2.874 3.207 3.374 4.165 6.497 7.080 8.955 9.204 0.00801 0.02001 0.27618 0.30820 0.32421 0.40026 0.62440 0.68044 0.86055 0.88457 1.278E-04 1.152E-04 1.139E-04 1.077E-04 9.468E-05 8.713E-05 8.640E-05 8.562E-05 7.212E-05 6.892E-05 12.287 13.120 14.994 18.242 18.492 19.117 21.158 22.616 23.990 24.073 1.18076 1.26081 1.44092 1.75312 1.77714 1.83718 2.03330 2.17339 2.30548 2.31348 6.753E-05 6.753E-05 6.732E-05 6.414E-05 5.420E-05 5.399E-05 4.926E-05 4.507E-05 4.363E-05 4.254E-05 29.696 31.237 38.317 38.609 40.192 47.147 47.813 51.978 52.228 55.060 2.85383 3.00192 3.68236 3.71037 3.86247 4.53090 4.59494 4.99520 5.01921 5.29139 3.831E-05 3.387E-05 3.344E-05 3.179E-05 3.019E-05 2.909E-05 2.727E-05 2.653E-05 2.247E-05 2.045E-05 58.642 61.308 61.349 65.889 65.973 66.222 66.764 70.970 71.304 71.387 5.63561 5.89177 5.89577 6.33205 6.34006 6.36407 6.41611 6.82036 6.85238 6.86039 1.994E-05 1.818E-05 1.693E-05 1.605E-05 1.546E-05 1.357E-05 1.133E-05 1.070E-05 1.039E-05 8.515E-06 76.093 76.177 76.801 77.593 77.718 78.634 79.384 80.258 80.550 81.258 7.31268 7.32068 7.38072 7.45677 7.46878 7.55684 7.62888 7.71293 7.74095 7.80900

LR-N23-0050 LAR S23-04 LAR H23-02 7.826E-06 6.913E-06 6.855E-06 6.277E-06 5.239E-06 4.683E-06 4.570E-06 3.937E-06 3.541E-06 3.170E-06 81.883 82.007 82.091 82.757 83.757 83.840 83.882 84.631 84.798 85.090 7.86903 7.88104 7.88905 7.95309 8.04915 8.05715 8.06116 8.13320 8.14921 8.17723 2.380E-06 2.113E-06 1.792E-06 1.437E-06 1.200E-06 9.017E-07 7.259E-07 4.839E-07 86.047 86.089 88.005 91.545 95.085 99.000 99.500 100.000 8.26929 8.27329 8.45741 8.79763 9.13785 9.51409 9.56212 9.61015 X/Q PERCENTILES (BASED ON THE UPPER ENVELOPE OF THE ORDERED X/Q-FREQUENCY VALUES, AND AS PLOTTED ON A LOG-NORMAL GRAPH.)

PERCENT OF TIME CHI/Q IS EQUALED OR EXCEEDED CHI/Q WITH RESPECT TO WHEN THE WIND BLOWS SEC/CUBIC METER THE TOTAL TIME INTO THIS SECTOR ONLY HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 3)=

0.624 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 4)=

1.751 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 5)=

3.679 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 6)=

4.527 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 7)=

5.288 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 8)=

6.328 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 9)=

6.817 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE(10)=

7.309 K I XQSAVE(K,I) XQINT(K,I) XQSLOP(K,I) 7 1 -7.68934 -10.32060 -0.69703 7 2 -8.41121 -11.45277 -1.11034 7 3 -8.67863 -11.60505 -1.17129 7 4 -9.13588 -12.24378 -1.47428 7 5 -9.60600 -13.68986 -2.28250

LR-N23-0050 LAR S23-04 LAR H23-02 7 6 -9.82667 -15.21191 -3.18179 7 7 -10.06511 -15.31262 -3.24405 7 8 -10.35639 -17.58298 -4.73008 7 9 -10.53706 -22.21581 -7.84020 7 10 -10.82267 NUMXQ(K)= 10 2.864E-04 0.096 1.000 2.258E-04 0.288 3.000 1.884E-04 0.481 5.000 1.416E-04 0.961 10.000 1.181E-04 1.442 15.000 1.019E-04 1.922 20.000 8.885E-05 2.403 25.000 7.912E-05 2.883 30.000 7.153E-05 3.364 35.000 6.436E-05 3.844 40.000 5.678E-05 4.325 45.000 4.937E-05 4.805 50.000 4.261E-05 5.286 55.000 3.706E-05 5.766 60.000 3.251E-05 6.247 65.000 2.744E-05 6.727 70.000 2.117E-05 7.208 75.000 1.855E-04 0.5 5.20 ANNUAL AVERAGE = 2.44E-06 K= 7 FIVEXQ(K)= 1.855E-04 FIVEPR(K)= 5.203

LR-N23-0050 LAR S23-04 LAR H23-02 USNRC COMPUTER CODE-PAVAN, VERSION 2.0 RUN DATE: 03-03-2023 PLANT NAME: SGS EAB METEOROLOGICAL INSTRUMENTATION DATA PERIOD: 2019-2021 WIND SENSORS HEIGHT: 10 m TYPE OF RELEASE: Ground Level DELTA-T HEIGHTS: 10 m - 46 m SOURCE OF DATA: A-5-ZZ-MDC-2391 COMMENTS: 695 m and 790 m EAB PROGRAM: PAVAN, 10/76, 8/79 REVISION, IMPLEMENTATION OF REGULATORY GUIDE 1.145 LOW POPULATION ZONE CALCULATIONS:

NNW SECTOR BOUNDARY DISTANCE = 790.0 METERS LATERAL PLUME MEANDER/BUILDING WAKE CREDIT ALLOWED AS A FUNCTION OF DOWNWIND DISTANCE.

MEANDER CREDIT IS FOR WINDSPEEDS LESS THAN 6 MPS.

BUILDING WAKE CREDIT ALLOWED: C= 0.5 A= 2399. D= 58.3 BELOW ARE PRINTED THE ORDERED VALUES OF CHI/Q AND THE FREQUENCY WITH WHICH THAT VALUE IS REACHED OR EXCEEDED.

THE TOP NUMBER IS THE CHI/Q. THE MIDDLE NUMBER IS THE FREQUENCY NORMALIZED TO THIS SECTOR.

THE THIRD NUMBER IS THE FREQUENCY WITH RESPECT TO ALL TIME.

3.282E-04 2.249E-04 2.224E-04 2.179E-04 1.750E-04 1.702E-04 1.476E-04 1.365E-04 1.286E-04 1.278E-04 0.243 1.639 2.550 2.732 3.461 4.797 5.464 6.557 7.165 10.808 0.01601 0.10807 0.16811 0.18012 0.22815 0.31620 0.36023 0.43228 0.47230 0.71246 1.152E-04 1.139E-04 1.077E-04 9.468E-05 8.713E-05 8.640E-05 8.562E-05 7.212E-05 6.753E-05 6.753E-05 12.386 12.933 15.240 15.422 16.636 17.365 17.972 18.519 26.108 29.630 0.81652 0.85255 1.00464 1.01665 1.09670 1.14473 1.18476 1.22078 1.72110 1.95325 6.732E-05 6.414E-05 5.420E-05 5.399E-05 4.926E-05 4.507E-05 4.422E-05 4.363E-05 4.254E-05 3.831E-05 36.976 38.069 38.494 44.869 46.509 50.334 50.395 50.638 55.252 60.413 2.43756 2.50961 2.53762 2.95789 3.06596 3.31812 3.32213 3.33814 3.64233 3.98255 3.387E-05 3.179E-05 2.909E-05 2.727E-05 2.653E-05 2.247E-05 1.994E-05 1.818E-05 1.693E-05 1.605E-05 62.417 68.610 68.731 69.156 75.288 76.442 81.542 81.603 82.332 82.817 4.11463 4.52289 4.53090 4.55892 4.96318 5.03922 5.37544 5.37944 5.42747 5.45949 1.357E-05 1.133E-05 1.070E-05 1.039E-05 8.515E-06 7.826E-06 6.913E-06 6.277E-06 5.239E-06 4.683E-06 83.667 84.092 84.214 85.185 85.732 86.339 86.460 86.764 87.189 87.492 5.51553 5.54355 5.55155 5.61559 5.65162 5.69164 5.69965 5.71966 5.74768 5.76769

LR-N23-0050 LAR S23-04 LAR H23-02 4.570E-06 3.937E-06 3.541E-06 2.380E-06 1.792E-06 1.437E-06 1.200E-06 9.017E-07 7.259E-07 4.839E-07 87.675 87.978 88.525 89.800 91.803 94.414 96.721 99.454 99.879 100.000 5.77970 5.79971 5.83573 5.91979 6.05187 6.22398 6.37608 6.55620 6.58421 6.59222 X/Q PERCENTILES (BASED ON THE UPPER ENVELOPE OF THE ORDERED X/Q-FREQUENCY VALUES, AND AS PLOTTED ON A LOG-NORMAL GRAPH.)

PERCENT OF TIME CHI/Q IS EQUALED OR EXCEEDED CHI/Q WITH RESPECT TO WHEN THE WIND BLOWS SEC/CUBIC METER THE TOTAL TIME INTO THIS SECTOR ONLY HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 4)=

0.712 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 5)=

1.003 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 6)=

2.435 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 7)=

3.979 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 8)=

4.519 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 9)=

4.959 K I XQSAVE(K,I) XQINT(K,I) XQSLOP(K,I) 8 1 -8.02175 -10.12716 -0.58508 8 2 -8.41121 -11.15032 -0.93394 8 3 -8.43128 -11.80992 -1.16050 8 4 -8.96514 -12.27910 -1.35189 8 5 -9.13588 -12.22486 -1.32857 8 6 -9.60600 -14.70171 -2.58509 8 7 -10.16978 -15.64551 -3.12345 8 8 -10.35639 -17.22107 -4.05388 8 9 -10.53706 NUMXQ(K)= 9 2.618E-04 0.066 1.000 2.106E-04 0.198 3.000 1.740E-04 0.330 5.000 1.320E-04 0.659 10.000

LR-N23-0050 LAR S23-04 LAR H23-02 1.086E-04 0.989 15.000 9.384E-05 1.318 20.000 8.347E-05 1.648 25.000 7.564E-05 1.978 30.000 6.944E-05 2.307 35.000 6.171E-05 2.637 40.000 5.404E-05 2.966 45.000 4.788E-05 3.296 50.000 4.283E-05 3.626 55.000 3.863E-05 3.955 60.000 3.443E-05 4.285 65.000 3.058E-05 4.615 70.000 2.674E-05 4.944 75.000 1.477E-04 0.5 7.58 ANNUAL AVERAGE = 1.82E-06 K= 8 FIVEXQ(K)= 1.477E-04 FIVEPR(K)= 7.585

LR-N23-0050 LAR S23-04 LAR H23-02 USNRC COMPUTER CODE-PAVAN, VERSION 2.0 RUN DATE: 03-03-2023 PLANT NAME: SGS EAB METEOROLOGICAL INSTRUMENTATION DATA PERIOD: 2019-2021 WIND SENSORS HEIGHT: 10 m TYPE OF RELEASE: Ground Level DELTA-T HEIGHTS: 10 m - 46 m SOURCE OF DATA: A-5-ZZ-MDC-2391 COMMENTS: 695 m and 790 m EAB PROGRAM: PAVAN, 10/76, 8/79 REVISION, IMPLEMENTATION OF REGULATORY GUIDE 1.145 LOW POPULATION ZONE CALCULATIONS:

N SECTOR BOUNDARY DISTANCE = 790.0 METERS LATERAL PLUME MEANDER/BUILDING WAKE CREDIT ALLOWED AS A FUNCTION OF DOWNWIND DISTANCE.

MEANDER CREDIT IS FOR WINDSPEEDS LESS THAN 6 MPS.

BUILDING WAKE CREDIT ALLOWED: C= 0.5 A= 2399. D= 58.3 BELOW ARE PRINTED THE ORDERED VALUES OF CHI/Q AND THE FREQUENCY WITH WHICH THAT VALUE IS REACHED OR EXCEEDED.

THE TOP NUMBER IS THE CHI/Q. THE MIDDLE NUMBER IS THE FREQUENCY NORMALIZED TO THIS SECTOR.

THE THIRD NUMBER IS THE FREQUENCY WITH RESPECT TO ALL TIME.

6.893E-04 3.282E-04 2.249E-04 2.224E-04 2.179E-04 1.750E-04 1.702E-04 1.476E-04 1.365E-04 1.286E-04 0.068 0.548 1.370 2.055 2.466 2.945 3.562 4.658 5.342 5.822 0.00400 0.03202 0.08005 0.12008 0.14409 0.17211 0.20813 0.27217 0.31220 0.34022 1.278E-04 1.152E-04 1.139E-04 1.077E-04 9.468E-05 8.713E-05 8.640E-05 8.562E-05 7.212E-05 6.892E-05 7.877 9.110 9.315 10.274 10.479 11.986 12.740 13.356 13.836 14.452 0.46029 0.53234 0.54435 0.60038 0.61239 0.70045 0.74448 0.78050 0.80852 0.84454 6.753E-05 6.753E-05 6.732E-05 6.528E-05 6.414E-05 5.420E-05 5.399E-05 4.926E-05 4.595E-05 4.507E-05 23.288 26.781 33.082 33.151 34.521 35.342 40.890 43.425 43.699 46.849 1.36087 1.56500 1.93324 1.93724 2.01729 2.06532 2.38953 2.53762 2.55363 2.73775 4.422E-05 4.363E-05 4.254E-05 3.831E-05 3.387E-05 3.344E-05 3.179E-05 2.909E-05 2.727E-05 2.653E-05 46.918 47.466 55.959 63.151 65.068 65.137 72.945 73.288 73.767 80.548 2.74175 2.77378 3.27009 3.69036 3.80243 3.80644 4.26273 4.28274 4.31076 4.70701 2.247E-05 1.994E-05 1.818E-05 1.693E-05 1.605E-05 1.357E-05 1.133E-05 1.070E-05 1.039E-05 8.515E-06 81.438 86.575 86.712 87.466 88.014 88.630 89.315 89.521 90.000 91.096 4.75905 5.05924 5.06724 5.11127 5.14329 5.17932 5.21934 5.23135 5.25937 5.32341

LR-N23-0050 LAR S23-04 LAR H23-02 7.826E-06 6.913E-06 6.855E-06 6.277E-06 5.239E-06 4.683E-06 3.937E-06 3.541E-06 3.170E-06 2.380E-06 91.712 91.781 91.849 92.192 92.329 92.945 93.562 93.904 93.973 94.932 5.35943 5.36343 5.36744 5.38745 5.39545 5.43148 5.46750 5.48751 5.49152 5.54755 1.792E-06 1.437E-06 1.200E-06 9.017E-07 7.259E-07 4.839E-07 96.438 98.219 99.041 99.726 99.932 100.000 5.63561 5.73968 5.78771 5.82773 5.83974 5.84374 X/Q PERCENTILES (BASED ON THE UPPER ENVELOPE OF THE ORDERED X/Q-FREQUENCY VALUES, AND AS PLOTTED ON A LOG-NORMAL GRAPH.)

PERCENT OF TIME CHI/Q IS EQUALED OR EXCEEDED CHI/Q WITH RESPECT TO WHEN THE WIND BLOWS SEC/CUBIC METER THE TOTAL TIME INTO THIS SECTOR ONLY HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 2)=

0.144 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 3)=

0.460 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 4)=

0.600 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 5)=

1.931 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 6)=

2.387 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 7)=

3.267 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 8)=

3.687 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 9)=

4.259 K I XQSAVE(K,I) XQINT(K,I) XQSLOP(K,I) 9 1 -7.27981 -11.99162 -1.19459 9 2 -8.43128 -12.66664 -1.42108 9 3 -8.96514 -13.77942 -1.84830 9 4 -9.13588 -11.79506 -1.05845 9 5 -9.60600 -14.76181 -2.49292

LR-N23-0050 LAR S23-04 LAR H23-02 9 6 -9.82667 -13.27850 -1.74365 9 7 -10.06511 -13.59106 -1.91325 9 8 -10.16978 -15.16191 -2.79170 9 9 -10.35639 NUMXQ(K)= 9 2.996E-04 0.058 1.000 2.000E-04 0.175 3.000 1.586E-04 0.292 5.000 1.096E-04 0.584 10.000 9.323E-05 0.877 15.000 8.315E-05 1.169 20.000 7.586E-05 1.461 25.000 7.023E-05 1.753 30.000 6.353E-05 2.045 35.000 5.526E-05 2.337 40.000 5.027E-05 2.630 45.000 4.641E-05 2.922 50.000 4.312E-05 3.214 55.000 4.006E-05 3.506 60.000 3.692E-05 3.798 65.000 3.355E-05 4.091 70.000 1.212E-04 0.5 8.56 ANNUAL AVERAGE = 1.69E-06 K= 9 FIVEXQ(K)= 1.212E-04 FIVEPR(K)= 8.556

LR-N23-0050 LAR S23-04 LAR H23-02 USNRC COMPUTER CODE-PAVAN, VERSION 2.0 RUN DATE: 03-03-2023 PLANT NAME: SGS EAB METEOROLOGICAL INSTRUMENTATION DATA PERIOD: 2019-2021 WIND SENSORS HEIGHT: 10 m TYPE OF RELEASE: Ground Level DELTA-T HEIGHTS: 10 m - 46 m SOURCE OF DATA: A-5-ZZ-MDC-2391 COMMENTS: 695 m and 790 m EAB PROGRAM: PAVAN, 10/76, 8/79 REVISION, IMPLEMENTATION OF REGULATORY GUIDE 1.145 LOW POPULATION ZONE CALCULATIONS:

NNE SECTOR BOUNDARY DISTANCE = 790.0 METERS LATERAL PLUME MEANDER/BUILDING WAKE CREDIT ALLOWED AS A FUNCTION OF DOWNWIND DISTANCE.

MEANDER CREDIT IS FOR WINDSPEEDS LESS THAN 6 MPS.

BUILDING WAKE CREDIT ALLOWED: C= 0.5 A= 2399. D= 58.3 BELOW ARE PRINTED THE ORDERED VALUES OF CHI/Q AND THE FREQUENCY WITH WHICH THAT VALUE IS REACHED OR EXCEEDED.

THE TOP NUMBER IS THE CHI/Q. THE MIDDLE NUMBER IS THE FREQUENCY NORMALIZED TO THIS SECTOR.

THE THIRD NUMBER IS THE FREQUENCY WITH RESPECT TO ALL TIME.

3.282E-04 2.249E-04 2.224E-04 2.179E-04 1.750E-04 1.702E-04 1.476E-04 1.365E-04 1.286E-04 1.278E-04 0.346 1.245 1.729 1.936 2.420 3.043 4.149 5.187 6.086 8.160 0.02001 0.07205 0.10006 0.11207 0.14009 0.17611 0.24015 0.30019 0.35223 0.47230 1.152E-04 1.139E-04 1.077E-04 9.468E-05 8.713E-05 8.640E-05 8.562E-05 7.212E-05 6.892E-05 6.753E-05 9.474 10.166 11.549 11.826 14.315 15.284 15.837 16.943 17.497 33.195 0.54835 0.58838 0.66843 0.68444 0.82853 0.88457 0.91659 0.98063 1.01265 1.92123 6.753E-05 6.732E-05 6.528E-05 6.414E-05 5.420E-05 5.399E-05 4.926E-05 4.507E-05 4.422E-05 4.363E-05 38.797 49.862 50.000 51.521 52.905 58.921 61.411 64.730 64.938 65.353 2.24544 2.88585 2.89385 2.98191 3.06196 3.41018 3.55428 3.74640 3.75841 3.78242 4.254E-05 3.831E-05 3.387E-05 3.344E-05 3.179E-05 2.909E-05 2.727E-05 2.653E-05 2.247E-05 2.045E-05 73.790 81.051 82.573 82.780 88.243 88.382 88.451 90.456 91.978 92.047 4.27073 4.69100 4.77906 4.79107 5.10727 5.11527 5.11928 5.23535 5.32341 5.32741 1.994E-05 1.693E-05 1.546E-05 1.357E-05 1.133E-05 1.039E-05 8.515E-06 7.826E-06 6.913E-06 6.277E-06 92.808 93.223 93.361 93.707 93.845 94.606 94.675 95.297 95.505 95.712 5.37144 5.39545 5.40346 5.42347 5.43148 5.47550 5.47951 5.51553 5.52754 5.53954

LR-N23-0050 LAR S23-04 LAR H23-02 5.239E-06 4.683E-06 3.541E-06 2.380E-06 1.792E-06 1.437E-06 1.200E-06 9.017E-07 7.259E-07 4.839E-07 95.781 96.127 96.680 97.510 98.271 98.617 99.585 99.862 99.931 100.000 5.54355 5.56356 5.59558 5.64361 5.68764 5.70765 5.76369 5.77970 5.78370 5.78770 X/Q PERCENTILES (BASED ON THE UPPER ENVELOPE OF THE ORDERED X/Q-FREQUENCY VALUES, AND AS PLOTTED ON A LOG-NORMAL GRAPH.)

PERCENT OF TIME CHI/Q IS EQUALED OR EXCEEDED CHI/Q WITH RESPECT TO WHEN THE WIND BLOWS SEC/CUBIC METER THE TOTAL TIME INTO THIS SECTOR ONLY HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 3)=

0.472 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 4)=

0.668 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 6)=

4.267 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 7)=

4.687 K I XQSAVE(K,I) XQINT(K,I) XQSLOP(K,I) 10 1 -8.02175 -11.01992 -0.84692 10 2 -8.43128 -11.97361 -1.15894 10 3 -8.96514 -12.60835 -1.40346 10 4 -9.13588 -11.15544 -0.81624 10 5 -9.60600 -14.50805 -2.58239 10 6 -10.06511 -14.10916 -2.35054 10 7 -10.16978 NUMXQ(K)= 7 2.566E-04 0.058 1.000 1.867E-04 0.174 3.000 1.545E-04 0.289 5.000 1.157E-04 0.579 10.000 9.970E-05 0.868 15.000 9.129E-05 1.158 20.000 8.506E-05 1.447 25.000 8.015E-05 1.736 30.000 7.613E-05 2.026 35.000 7.274E-05 2.315 40.000

LR-N23-0050 LAR S23-04 LAR H23-02 6.982E-05 2.604 45.000 6.711E-05 2.894 50.000 6.020E-05 3.183 55.000 5.442E-05 3.473 60.000 4.953E-05 3.762 65.000 4.534E-05 4.051 70.000 4.178E-05 4.341 75.000 3.888E-05 4.630 80.000 1.243E-04 0.5 8.64 ANNUAL AVERAGE = 1.88E-06 K= 10 FIVEXQ(K)= 1.243E-04 FIVEPR(K)= 8.639

LR-N23-0050 LAR S23-04 LAR H23-02

- 100 -

USNRC COMPUTER CODE-PAVAN, VERSION 2.0 RUN DATE: 03-03-2023 PLANT NAME: SGS EAB METEOROLOGICAL INSTRUMENTATION DATA PERIOD: 2019-2021 WIND SENSORS HEIGHT: 10 m TYPE OF RELEASE: Ground Level DELTA-T HEIGHTS: 10 m - 46 m SOURCE OF DATA: A-5-ZZ-MDC-2391 COMMENTS: 695 m and 790 m EAB PROGRAM: PAVAN, 10/76, 8/79 REVISION, IMPLEMENTATION OF REGULATORY GUIDE 1.145 LOW POPULATION ZONE CALCULATIONS:

NE SECTOR BOUNDARY DISTANCE = 790.0 METERS LATERAL PLUME MEANDER/BUILDING WAKE CREDIT ALLOWED AS A FUNCTION OF DOWNWIND DISTANCE.

MEANDER CREDIT IS FOR WINDSPEEDS LESS THAN 6 MPS.

BUILDING WAKE CREDIT ALLOWED: C= 0.5 A= 2399. D= 58.3 BELOW ARE PRINTED THE ORDERED VALUES OF CHI/Q AND THE FREQUENCY WITH WHICH THAT VALUE IS REACHED OR EXCEEDED.

THE TOP NUMBER IS THE CHI/Q. THE MIDDLE NUMBER IS THE FREQUENCY NORMALIZED TO THIS SECTOR.

THE THIRD NUMBER IS THE FREQUENCY WITH RESPECT TO ALL TIME.

3.282E-04 2.249E-04 2.224E-04 2.179E-04 1.750E-04 1.702E-04 1.476E-04 1.365E-04 1.286E-04 1.278E-04 0.132 1.516 1.780 2.637 2.769 3.560 4.417 4.878 5.603 11.734 0.00801 0.09206 0.10807 0.16010 0.16811 0.21614 0.26817 0.29619 0.34022 0.71246 1.152E-04 1.139E-04 1.077E-04 9.468E-05 8.713E-05 8.640E-05 7.212E-05 6.753E-05 6.753E-05 6.732E-05 13.975 14.305 16.941 17.139 19.644 21.490 22.742 42.848 48.715 61.503 0.84854 0.86856 1.02866 1.04067 1.19276 1.30484 1.38088 2.60167 2.95789 3.73439 6.414E-05 5.420E-05 5.399E-05 4.926E-05 4.507E-05 4.422E-05 4.363E-05 4.254E-05 3.831E-05 3.387E-05 62.294 63.151 67.106 69.018 70.929 71.061 71.391 78.444 84.443 85.695 3.78242 3.83445 4.07461 4.19068 4.30676 4.31476 4.33477 4.76305 5.12728 5.20333 3.344E-05 3.179E-05 3.019E-05 2.653E-05 2.247E-05 1.994E-05 1.693E-05 1.546E-05 1.357E-05 1.039E-05 85.827 87.871 87.937 88.662 90.046 90.508 91.167 91.365 91.826 92.353 5.21134 5.33541 5.33942 5.38345 5.46750 5.49552 5.53554 5.54755 5.57557 5.60759 8.515E-06 7.826E-06 6.277E-06 5.239E-06 4.683E-06 3.937E-06 3.541E-06 2.380E-06 1.792E-06 1.437E-06 92.419 92.881 93.210 93.276 93.408 93.474 93.804 95.517 97.825 99.539 5.61159 5.63961 5.65962 5.66362 5.67163 5.67563 5.69564 5.79971 5.93980 6.04387

LR-N23-0050 LAR S23-04 LAR H23-02

- 101 -

1.200E-06 9.017E-07 7.259E-07 99.868 99.934 100.000 6.06388 6.06788 6.07188 X/Q PERCENTILES (BASED ON THE UPPER ENVELOPE OF THE ORDERED X/Q-FREQUENCY VALUES, AND AS PLOTTED ON A LOG-NORMAL GRAPH.)

PERCENT OF TIME CHI/Q IS EQUALED OR EXCEEDED CHI/Q WITH RESPECT TO WHEN THE WIND BLOWS SEC/CUBIC METER THE TOTAL TIME INTO THIS SECTOR ONLY HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 3)=

0.712 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 4)=

2.955 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 6)=

5.124 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 7)=

5.332 K I XQSAVE(K,I) XQINT(K,I) XQSLOP(K,I) 11 1 -8.02175 -9.89117 -0.49522 11 2 -8.43128 -11.60028 -1.07497 11 3 -8.96514 -11.73792 -1.13113 11 4 -9.60299 -9.65728 -0.02877 11 5 -9.60600 -16.31613 -3.76386 11 6 -10.16978 -25.81620 -9.58146 11 7 -10.35639 NUMXQ(K)= 7 2.513E-04 0.061 1.000 2.087E-04 0.182 3.000 1.751E-04 0.304 5.000 1.359E-04 0.607 10.000 1.155E-04 0.911 15.000 1.021E-04 1.214 20.000 9.252E-05 1.518 25.000 8.516E-05 1.822 30.000 7.925E-05 2.125 35.000 7.437E-05 2.429 40.000

LR-N23-0050 LAR S23-04 LAR H23-02

- 102 -

7.023E-05 2.732 45.000 6.750E-05 3.036 50.000 6.742E-05 3.340 55.000 6.735E-05 3.643 60.000 6.117E-05 3.947 65.000 5.371E-05 4.250 70.000 4.750E-05 4.554 75.000 4.228E-05 4.858 80.000 3.715E-05 5.161 85.000 1.461E-04 0.5 8.23 ANNUAL AVERAGE = 2.07E-06 K= 11 FIVEXQ(K)= 1.461E-04 FIVEPR(K)= 8.235

LR-N23-0050 LAR S23-04 LAR H23-02

- 103 -

USNRC COMPUTER CODE-PAVAN, VERSION 2.0 RUN DATE: 03-03-2023 PLANT NAME: SGS EAB METEOROLOGICAL INSTRUMENTATION DATA PERIOD: 2019-2021 WIND SENSORS HEIGHT: 10 m TYPE OF RELEASE: Ground Level DELTA-T HEIGHTS: 10 m - 46 m SOURCE OF DATA: A-5-ZZ-MDC-2391 COMMENTS: 695 m and 790 m EAB PROGRAM: PAVAN, 10/76, 8/79 REVISION, IMPLEMENTATION OF REGULATORY GUIDE 1.145 LOW POPULATION ZONE CALCULATIONS:

ENE SECTOR BOUNDARY DISTANCE = 790.0 METERS LATERAL PLUME MEANDER/BUILDING WAKE CREDIT ALLOWED AS A FUNCTION OF DOWNWIND DISTANCE.

MEANDER CREDIT IS FOR WINDSPEEDS LESS THAN 6 MPS.

BUILDING WAKE CREDIT ALLOWED: C= 0.5 A= 2399. D= 58.3 BELOW ARE PRINTED THE ORDERED VALUES OF CHI/Q AND THE FREQUENCY WITH WHICH THAT VALUE IS REACHED OR EXCEEDED.

THE TOP NUMBER IS THE CHI/Q. THE MIDDLE NUMBER IS THE FREQUENCY NORMALIZED TO THIS SECTOR.

THE THIRD NUMBER IS THE FREQUENCY WITH RESPECT TO ALL TIME.

2.701E-04 2.249E-04 2.224E-04 2.179E-04 1.750E-04 1.702E-04 1.476E-04 1.365E-04 1.286E-04 1.278E-04 0.066 0.795 0.927 1.391 1.656 1.921 2.583 2.649 3.510 8.609 0.00400 0.04803 0.05604 0.08405 0.10006 0.11607 0.15610 0.16010 0.21214 0.52033 1.152E-04 1.077E-04 9.468E-05 8.713E-05 8.640E-05 7.212E-05 6.753E-05 6.753E-05 6.732E-05 6.528E-05 10.066 13.046 13.179 16.159 17.417 17.748 35.099 40.066 55.033 55.099 0.60839 0.78850 0.79651 0.97663 1.05267 1.07269 2.12136 2.42155 3.32613 3.33013 6.414E-05 5.420E-05 5.399E-05 4.926E-05 4.507E-05 4.254E-05 3.831E-05 3.387E-05 3.344E-05 3.179E-05 55.894 55.960 60.132 62.053 63.245 68.344 75.828 76.159 76.358 80.132 3.37816 3.38216 3.63433 3.75040 3.82245 4.13064 4.58293 4.60295 4.61495 4.84310 2.727E-05 2.653E-05 2.247E-05 1.994E-05 1.693E-05 1.605E-05 1.546E-05 1.357E-05 1.133E-05 1.039E-05 80.265 82.781 83.576 85.364 85.960 86.159 86.424 87.020 87.219 87.417 4.85110 5.00320 5.05123 5.15930 5.19532 5.20733 5.22334 5.25937 5.27137 5.28338 8.515E-06 7.826E-06 6.913E-06 6.277E-06 5.239E-06 4.683E-06 3.937E-06 3.541E-06 2.380E-06 1.792E-06 87.682 88.477 88.675 89.073 89.272 89.338 89.470 89.735 92.053 95.298 5.29939 5.34742 5.35943 5.38344 5.39545 5.39946 5.40746 5.42347 5.56356 5.75969

LR-N23-0050 LAR S23-04 LAR H23-02

- 104 -

1.437E-06 1.200E-06 9.017E-07 98.411 99.735 100.000 5.94781 6.02786 6.04387 X/Q PERCENTILES (BASED ON THE UPPER ENVELOPE OF THE ORDERED X/Q-FREQUENCY VALUES, AND AS PLOTTED ON A LOG-NORMAL GRAPH.)

PERCENT OF TIME CHI/Q IS EQUALED OR EXCEEDED CHI/Q WITH RESPECT TO WHEN THE WIND BLOWS SEC/CUBIC METER THE TOTAL TIME INTO THIS SECTOR ONLY HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 5)=

4.579 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 6)=

4.839 K I XQSAVE(K,I) XQINT(K,I) XQSLOP(K,I) 12 1 -8.21666 -9.27147 -0.26743 12 2 -8.43128 -11.32652 -0.92154 12 3 -8.96514 -11.22355 -0.88136 12 4 -9.60600 -16.58717 -3.80384 12 5 -10.16978 -22.06787 -7.05246 12 6 -10.35639 NUMXQ(K)= 6 2.236E-04 0.060 1.000 1.759E-04 0.181 3.000 1.513E-04 0.302 5.000 1.220E-04 0.604 10.000 1.072E-04 0.907 15.000 9.744E-05 1.209 20.000 9.024E-05 1.511 25.000 8.460E-05 1.813 30.000 7.999E-05 2.115 35.000 7.613E-05 2.418 40.000 7.280E-05 2.720 45.000 6.991E-05 3.022 50.000 6.734E-05 3.324 55.000 5.802E-05 3.626 60.000 5.045E-05 3.929 65.000

LR-N23-0050 LAR S23-04 LAR H23-02

- 105 -

4.424E-05 4.231 70.000 3.908E-05 4.533 75.000 3.197E-05 4.835 80.000 1.294E-04 0.5 8.27 ANNUAL AVERAGE = 1.84E-06 K= 12 FIVEXQ(K)= 1.294E-04 FIVEPR(K)= 8.273

LR-N23-0050 LAR S23-04 LAR H23-02

- 106 -

USNRC COMPUTER CODE-PAVAN, VERSION 2.0 RUN DATE: 03-03-2023 PLANT NAME: SGS EAB METEOROLOGICAL INSTRUMENTATION DATA PERIOD: 2019-2021 WIND SENSORS HEIGHT: 10 m TYPE OF RELEASE: Ground Level DELTA-T HEIGHTS: 10 m - 46 m SOURCE OF DATA: A-5-ZZ-MDC-2391 COMMENTS: 695 m and 790 m EAB PROGRAM: PAVAN, 10/76, 8/79 REVISION, IMPLEMENTATION OF REGULATORY GUIDE 1.145 LOW POPULATION ZONE CALCULATIONS:

E SECTOR BOUNDARY DISTANCE = 790.0 METERS LATERAL PLUME MEANDER/BUILDING WAKE CREDIT ALLOWED AS A FUNCTION OF DOWNWIND DISTANCE.

MEANDER CREDIT IS FOR WINDSPEEDS LESS THAN 6 MPS.

BUILDING WAKE CREDIT ALLOWED: C= 0.5 A= 2399. D= 58.3 BELOW ARE PRINTED THE ORDERED VALUES OF CHI/Q AND THE FREQUENCY WITH WHICH THAT VALUE IS REACHED OR EXCEEDED.

THE TOP NUMBER IS THE CHI/Q. THE MIDDLE NUMBER IS THE FREQUENCY NORMALIZED TO THIS SECTOR.

THE THIRD NUMBER IS THE FREQUENCY WITH RESPECT TO ALL TIME.

3.282E-04 2.701E-04 2.249E-04 2.224E-04 2.179E-04 1.988E-04 1.750E-04 1.476E-04 1.286E-04 1.278E-04 0.342 0.410 0.615 0.957 1.572 1.640 1.982 3.076 3.828 7.109 0.02001 0.02402 0.03602 0.05604 0.09206 0.09606 0.11607 0.18012 0.22414 0.41627 1.152E-04 1.077E-04 9.468E-05 8.713E-05 8.640E-05 6.753E-05 6.753E-05 6.732E-05 6.528E-05 6.414E-05 9.296 11.141 11.483 14.149 14.627 27.683 31.784 42.242 42.310 42.925 0.54435 0.65242 0.67243 0.82853 0.85655 1.62104 1.86119 2.47358 2.47759 2.51361 6.339E-05 5.420E-05 5.399E-05 4.926E-05 4.507E-05 4.422E-05 4.254E-05 3.831E-05 3.387E-05 3.344E-05 42.994 43.062 48.120 50.171 51.811 51.880 55.502 59.535 61.381 61.517 2.51761 2.52161 2.81780 2.93788 3.03394 3.03794 3.25008 3.48623 3.59430 3.60231 3.179E-05 2.727E-05 2.653E-05 2.247E-05 2.045E-05 1.994E-05 1.818E-05 1.693E-05 1.605E-05 1.546E-05 67.532 68.148 71.702 72.591 72.659 77.239 77.444 78.401 79.904 79.973 3.95453 3.99055 4.19869 4.25072 4.25472 4.52289 4.53490 4.59094 4.67899 4.68300 1.357E-05 1.133E-05 1.070E-05 1.039E-05 8.515E-06 7.826E-06 6.913E-06 6.855E-06 6.277E-06 5.239E-06 80.725 81.066 81.613 82.433 82.707 83.459 83.527 83.664 84.416 85.373 4.72703 4.74704 4.77906 4.82709 4.84310 4.88713 4.89113 4.89914 4.94316 4.99920

LR-N23-0050 LAR S23-04 LAR H23-02

- 107 -

4.683E-06 4.570E-06 3.937E-06 3.541E-06 3.170E-06 2.380E-06 2.113E-06 1.792E-06 1.437E-06 1.200E-06 85.509 85.578 86.398 86.466 86.603 87.286 87.355 89.200 92.413 94.668 5.00720 5.01121 5.05924 5.06324 5.07125 5.11127 5.11527 5.22334 5.41146 5.54355 9.017E-07 7.259E-07 4.839E-07 98.496 99.658 100.000 5.76769 5.83573 5.85575 X/Q PERCENTILES (BASED ON THE UPPER ENVELOPE OF THE ORDERED X/Q-FREQUENCY VALUES, AND AS PLOTTED ON A LOG-NORMAL GRAPH.)

PERCENT OF TIME CHI/Q IS EQUALED OR EXCEEDED CHI/Q WITH RESPECT TO WHEN THE WIND BLOWS SEC/CUBIC METER THE TOTAL TIME INTO THIS SECTOR ONLY HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 3)=

0.652 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 5)=

3.247 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 6)=

3.951 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 7)=

4.195 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 8)=

4.519 K I XQSAVE(K,I) XQINT(K,I) XQSLOP(K,I) 13 1 -8.02175 -11.43242 -0.96344 13 2 -8.43128 -11.90337 -1.11463 13 3 -9.13588 -11.38954 -0.90768 13 4 -9.60600 -17.16928 -3.84912 13 5 -10.06511 -16.08656 -3.26249 13 6 -10.35639 -21.72437 -6.47239 13 7 -10.53706 -24.60022 -8.13622 13 8 -10.82267 NUMXQ(K)= 8 2.473E-04 0.059 1.000 1.752E-04 0.176 3.000 1.461E-04 0.293 5.000

LR-N23-0050 LAR S23-04 LAR H23-02

- 108 -

1.124E-04 0.586 10.000 9.769E-05 0.878 15.000 8.855E-05 1.171 20.000 8.185E-05 1.464 25.000 7.661E-05 1.757 30.000 7.234E-05 2.050 35.000 6.876E-05 2.342 40.000 6.064E-05 2.635 45.000 5.083E-05 2.928 50.000 4.321E-05 3.221 55.000 3.794E-05 3.513 60.000 3.367E-05 3.806 65.000 2.854E-05 4.099 70.000 2.234E-05 4.392 75.000 1.195E-04 0.5 8.54 ANNUAL AVERAGE = 1.66E-06 K= 13 FIVEXQ(K)= 1.195E-04 FIVEPR(K)= 8.539

LR-N23-0050 LAR S23-04 LAR H23-02

- 109 -

USNRC COMPUTER CODE-PAVAN, VERSION 2.0 RUN DATE: 03-03-2023 PLANT NAME: SGS EAB METEOROLOGICAL INSTRUMENTATION DATA PERIOD: 2019-2021 WIND SENSORS HEIGHT: 10 m TYPE OF RELEASE: Ground Level DELTA-T HEIGHTS: 10 m - 46 m SOURCE OF DATA: A-5-ZZ-MDC-2391 COMMENTS: 695 m and 790 m EAB PROGRAM: PAVAN, 10/76, 8/79 REVISION, IMPLEMENTATION OF REGULATORY GUIDE 1.145 LOW POPULATION ZONE CALCULATIONS:

ESE SECTOR BOUNDARY DISTANCE = 790.0 METERS LATERAL PLUME MEANDER/BUILDING WAKE CREDIT ALLOWED AS A FUNCTION OF DOWNWIND DISTANCE.

MEANDER CREDIT IS FOR WINDSPEEDS LESS THAN 6 MPS.

BUILDING WAKE CREDIT ALLOWED: C= 0.5 A= 2399. D= 58.3 BELOW ARE PRINTED THE ORDERED VALUES OF CHI/Q AND THE FREQUENCY WITH WHICH THAT VALUE IS REACHED OR EXCEEDED.

THE TOP NUMBER IS THE CHI/Q. THE MIDDLE NUMBER IS THE FREQUENCY NORMALIZED TO THIS SECTOR.

THE THIRD NUMBER IS THE FREQUENCY WITH RESPECT TO ALL TIME.

3.282E-04 2.249E-04 2.224E-04 2.179E-04 1.750E-04 1.702E-04 1.476E-04 1.286E-04 1.278E-04 1.152E-04 0.062 0.125 0.374 1.059 1.432 1.494 2.553 3.861 6.476 7.846 0.00400 0.00801 0.02402 0.06804 0.09206 0.09606 0.16411 0.24816 0.41627 0.50432 1.077E-04 9.468E-05 8.713E-05 8.640E-05 6.753E-05 6.753E-05 6.732E-05 6.414E-05 5.399E-05 4.926E-05 9.153 9.340 12.391 12.453 23.163 28.518 37.796 39.103 44.707 46.326 0.58838 0.60038 0.79651 0.80051 1.48895 1.83317 2.42955 2.51361 2.87384 2.97791 4.507E-05 4.422E-05 4.254E-05 3.831E-05 3.387E-05 3.179E-05 3.019E-05 2.727E-05 2.653E-05 2.247E-05 48.070 48.132 53.051 57.721 59.963 64.819 64.882 65.691 69.427 70.112 3.08998 3.09398 3.41018 3.71037 3.85447 4.16667 4.17067 4.22270 4.46286 4.50688 2.045E-05 1.994E-05 1.818E-05 1.693E-05 1.605E-05 1.546E-05 1.357E-05 1.133E-05 1.070E-05 1.039E-05 70.174 75.841 75.903 76.401 78.144 78.269 78.767 79.514 79.826 80.262 4.51089 4.87512 4.87912 4.91114 5.02321 5.03122 5.06324 5.11127 5.13128 5.15930 8.515E-06 7.826E-06 6.855E-06 6.277E-06 5.239E-06 4.683E-06 4.570E-06 3.937E-06 3.541E-06 3.170E-06 81.445 81.880 82.316 82.752 83.437 83.748 83.811 85.430 85.990 86.675 5.23535 5.26337 5.29139 5.31940 5.36343 5.38345 5.38745 5.49151 5.52754 5.57157

LR-N23-0050 LAR S23-04 LAR H23-02

- 110 -

2.380E-06 2.113E-06 1.792E-06 1.437E-06 1.200E-06 9.017E-07 7.259E-07 4.839E-07 87.796 88.045 89.352 91.469 93.960 97.198 99.315 100.000 5.64361 5.65962 5.74368 5.87976 6.03987 6.24800 6.38409 6.42811 X/Q PERCENTILES (BASED ON THE UPPER ENVELOPE OF THE ORDERED X/Q-FREQUENCY VALUES, AND AS PLOTTED ON A LOG-NORMAL GRAPH.)

PERCENT OF TIME CHI/Q IS EQUALED OR EXCEEDED CHI/Q WITH RESPECT TO WHEN THE WIND BLOWS SEC/CUBIC METER THE TOTAL TIME INTO THIS SECTOR ONLY HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 5)=

3.707 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 6)=

4.163 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 7)=

4.459 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 8)=

4.871 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 9)=

5.020 K I XQSAVE(K,I) XQINT(K,I) XQSLOP(K,I) 14 1 -8.02175 -10.20104 -0.55252 14 2 -8.43128 -11.46263 -0.94639 14 3 -8.96514 -11.50304 -0.96170 14 4 -9.60600 -15.55741 -3.01705 14 5 -10.16978 -16.37741 -3.47624 14 6 -10.35639 -20.03136 -5.58585 14 7 -10.53706 -22.02478 -6.75866 14 8 -10.82267 -35.64726 -14.97761 14 9 -11.03958 NUMXQ(K)= 9 2.199E-04 0.064 1.000 1.621E-04 0.193 3.000 1.387E-04 0.321 5.000 1.105E-04 0.643 10.000 9.589E-05 0.964 15.000 8.631E-05 1.286 20.000

LR-N23-0050 LAR S23-04 LAR H23-02

- 111 -

7.932E-05 1.607 25.000 7.388E-05 1.928 30.000 6.946E-05 2.250 35.000 6.257E-05 2.571 40.000 5.363E-05 2.893 45.000 4.660E-05 3.214 50.000 4.094E-05 3.535 55.000 3.601E-05 3.857 60.000 3.156E-05 4.178 65.000 2.584E-05 4.500 70.000 2.068E-05 4.821 75.000 1.203E-04 0.5 7.78 ANNUAL AVERAGE = 1.72E-06 K= 14 FIVEXQ(K)= 1.203E-04 FIVEPR(K)= 7.778

LR-N23-0050 LAR S23-04 LAR H23-02

- 112 -

USNRC COMPUTER CODE-PAVAN, VERSION 2.0 RUN DATE: 03-03-2023 PLANT NAME: SGS EAB METEOROLOGICAL INSTRUMENTATION DATA PERIOD: 2019-2021 WIND SENSORS HEIGHT: 10 m TYPE OF RELEASE: Ground Level DELTA-T HEIGHTS: 10 m - 46 m SOURCE OF DATA: A-5-ZZ-MDC-2391 COMMENTS: 695 m and 790 m EAB PROGRAM: PAVAN, 10/76, 8/79 REVISION, IMPLEMENTATION OF REGULATORY GUIDE 1.145 LOW POPULATION ZONE CALCULATIONS:

SE SECTOR BOUNDARY DISTANCE = 790.0 METERS LATERAL PLUME MEANDER/BUILDING WAKE CREDIT ALLOWED AS A FUNCTION OF DOWNWIND DISTANCE.

MEANDER CREDIT IS FOR WINDSPEEDS LESS THAN 6 MPS.

BUILDING WAKE CREDIT ALLOWED: C= 0.5 A= 2399. D= 58.3 BELOW ARE PRINTED THE ORDERED VALUES OF CHI/Q AND THE FREQUENCY WITH WHICH THAT VALUE IS REACHED OR EXCEEDED.

THE TOP NUMBER IS THE CHI/Q. THE MIDDLE NUMBER IS THE FREQUENCY NORMALIZED TO THIS SECTOR.

THE THIRD NUMBER IS THE FREQUENCY WITH RESPECT TO ALL TIME.

4.577E-04 3.282E-04 2.249E-04 2.224E-04 2.179E-04 1.750E-04 1.702E-04 1.476E-04 1.286E-04 1.278E-04 0.073 0.110 0.879 1.136 1.539 1.942 2.272 3.115 3.738 10.150 0.00801 0.01201 0.09606 0.12408 0.16811 0.21214 0.24816 0.34022 0.40826 1.10871 1.152E-04 1.077E-04 9.468E-05 8.713E-05 8.640E-05 7.212E-05 6.753E-05 6.753E-05 6.732E-05 6.528E-05 11.763 14.657 14.804 16.306 16.636 16.673 24.954 27.519 34.995 35.031 1.28482 1.60102 1.61703 1.78114 1.81716 1.82117 2.72574 3.00592 3.82245 3.82645 6.414E-05 6.339E-05 5.399E-05 4.926E-05 4.507E-05 4.422E-05 4.254E-05 3.831E-05 3.387E-05 3.344E-05 35.544 35.581 42.690 43.679 47.856 47.893 50.678 55.112 58.483 58.703 3.88249 3.88649 4.66298 4.77105 5.22735 5.23135 5.53554 6.01985 6.38809 6.41210 3.179E-05 2.727E-05 2.653E-05 2.247E-05 1.994E-05 1.693E-05 1.605E-05 1.546E-05 1.357E-05 1.133E-05 63.357 63.796 68.010 68.487 75.009 75.449 76.695 76.768 77.831 78.747 6.92043 6.96846 7.42875 7.48079 8.19324 8.24127 8.37736 8.38537 8.50144 8.60151 1.070E-05 1.039E-05 8.515E-06 7.826E-06 6.913E-06 6.855E-06 6.277E-06 5.239E-06 4.683E-06 3.937E-06 78.857 79.040 80.066 80.762 80.835 81.129 81.678 82.484 82.594 84.097 8.61351 8.63353 8.74560 8.82165 8.82965 8.86167 8.92171 9.00977 9.02177 9.18588

LR-N23-0050 LAR S23-04 LAR H23-02

- 113 -

3.541E-06 3.170E-06 2.380E-06 1.792E-06 1.437E-06 1.200E-06 9.017E-07 7.259E-07 4.839E-07 84.317 84.903 85.746 87.028 89.190 92.928 96.995 99.743 100.000 9.20990 9.27394 9.36599 9.50608 9.74224 10.15050 10.59478 10.89497 10.92299 X/Q PERCENTILES (BASED ON THE UPPER ENVELOPE OF THE ORDERED X/Q-FREQUENCY VALUES, AND AS PLOTTED ON A LOG-NORMAL GRAPH.)

PERCENT OF TIME CHI/Q IS EQUALED OR EXCEEDED CHI/Q WITH RESPECT TO WHEN THE WIND BLOWS SEC/CUBIC METER THE TOTAL TIME INTO THIS SECTOR ONLY HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 3)=

1.599 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 4)=

3.819 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 5)=

4.659 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 6)=

6.917 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 7)=

7.425 K I XQSAVE(K,I) XQINT(K,I) XQSLOP(K,I) 15 1 -7.68934 -10.92783 -0.85789 15 2 -8.96514 -11.69274 -1.19223 15 3 -9.13588 -11.84228 -1.26196 15 4 -9.60600 -13.79943 -2.36640 15 5 -9.82667 -14.34582 -2.69187 15 6 -10.35639 -17.55830 -4.85948 15 7 -10.53706 NUMXQ(K)= 7 2.487E-04 0.109 1.000 1.850E-04 0.328 3.000 1.594E-04 0.546 5.000 1.284E-04 1.092 10.000 1.065E-04 1.638 15.000 9.176E-05 2.185 20.000 8.138E-05 2.731 25.000 7.353E-05 3.277 30.000

LR-N23-0050 LAR S23-04 LAR H23-02

- 114 -

6.731E-05 3.823 35.000 5.809E-05 4.369 40.000 5.043E-05 4.915 45.000 4.391E-05 5.461 50.000 3.863E-05 6.008 55.000 3.429E-05 6.554 60.000 2.979E-05 7.100 65.000 1.637E-04 0.5 4.58 ANNUAL AVERAGE = 2.72E-06 K= 15 FIVEXQ(K)= 1.637E-04 FIVEPR(K)= 4.578

LR-N23-0050 LAR S23-04 LAR H23-02

- 115 -

USNRC COMPUTER CODE-PAVAN, VERSION 2.0 RUN DATE: 03-03-2023 PLANT NAME: SGS EAB METEOROLOGICAL INSTRUMENTATION DATA PERIOD: 2019-2021 WIND SENSORS HEIGHT: 10 m TYPE OF RELEASE: Ground Level DELTA-T HEIGHTS: 10 m - 46 m SOURCE OF DATA: A-5-ZZ-MDC-2391 COMMENTS: 695 m and 790 m EAB PROGRAM: PAVAN, 10/76, 8/79 REVISION, IMPLEMENTATION OF REGULATORY GUIDE 1.145 LOW POPULATION ZONE CALCULATIONS:

SSE SECTOR BOUNDARY DISTANCE = 790.0 METERS LATERAL PLUME MEANDER/BUILDING WAKE CREDIT ALLOWED AS A FUNCTION OF DOWNWIND DISTANCE.

MEANDER CREDIT IS FOR WINDSPEEDS LESS THAN 6 MPS.

BUILDING WAKE CREDIT ALLOWED: C= 0.5 A= 2399. D= 58.3 BELOW ARE PRINTED THE ORDERED VALUES OF CHI/Q AND THE FREQUENCY WITH WHICH THAT VALUE IS REACHED OR EXCEEDED.

THE TOP NUMBER IS THE CHI/Q. THE MIDDLE NUMBER IS THE FREQUENCY NORMALIZED TO THIS SECTOR.

THE THIRD NUMBER IS THE FREQUENCY WITH RESPECT TO ALL TIME.

3.282E-04 2.249E-04 2.224E-04 2.179E-04 1.988E-04 1.750E-04 1.702E-04 1.476E-04 1.365E-04 1.286E-04 0.203 2.025 2.633 3.089 3.139 3.646 4.759 5.975 6.025 6.937 0.01601 0.16010 0.20813 0.24416 0.24816 0.28818 0.37624 0.47230 0.47630 0.54835 1.278E-04 1.152E-04 1.077E-04 9.468E-05 8.713E-05 8.640E-05 7.212E-05 6.753E-05 6.753E-05 6.732E-05 12.253 13.975 16.405 16.759 18.785 19.241 19.443 28.405 32.051 38.785 0.96862 1.10471 1.29683 1.32485 1.48495 1.52097 1.53698 2.24544 2.53362 3.06596 6.414E-05 5.399E-05 4.926E-05 4.507E-05 4.254E-05 3.831E-05 3.387E-05 3.344E-05 3.179E-05 2.727E-05 39.392 45.063 45.873 49.013 54.835 61.519 63.949 64.000 68.608 68.810 3.11399 3.56228 3.62632 3.87448 4.33477 4.86311 5.05523 5.05924 5.42347 5.43948 2.653E-05 2.247E-05 2.045E-05 1.994E-05 1.693E-05 1.605E-05 1.546E-05 1.357E-05 1.133E-05 1.070E-05 73.570 73.975 74.025 79.190 80.203 80.911 81.013 82.228 83.392 83.443 5.81572 5.84774 5.85174 6.26001 6.34006 6.39609 6.40410 6.50016 6.59222 6.59622 1.039E-05 8.515E-06 7.826E-06 6.913E-06 6.855E-06 6.277E-06 5.239E-06 4.683E-06 3.937E-06 3.541E-06 83.595 84.456 84.911 84.962 85.215 85.823 86.633 86.785 87.595 87.696 6.60823 6.67627 6.71230 6.71630 6.73631 6.78434 6.84838 6.86039 6.92443 6.93244

LR-N23-0050 LAR S23-04 LAR H23-02

- 116 -

3.170E-06 2.380E-06 1.792E-06 1.437E-06 1.200E-06 9.017E-07 7.259E-07 87.899 88.608 89.924 92.405 95.241 98.734 100.000 6.94845 7.00448 7.10855 7.30467 7.52882 7.80499 7.90506 X/Q PERCENTILES (BASED ON THE UPPER ENVELOPE OF THE ORDERED X/Q-FREQUENCY VALUES, AND AS PLOTTED ON A LOG-NORMAL GRAPH.)

PERCENT OF TIME CHI/Q IS EQUALED OR EXCEEDED CHI/Q WITH RESPECT TO WHEN THE WIND BLOWS SEC/CUBIC METER THE TOTAL TIME INTO THIS SECTOR ONLY HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 3)=

0.967 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 4)=

3.063 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 5)=

4.859 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 6)=

5.420 HANDCHECK GRAPH: SLOPE LT -1.0 FOR LOW PERCENTAGES. XSAVE( 7)=

5.812 K I XQSAVE(K,I) XQINT(K,I) XQSLOP(K,I) 16 1 -8.02175 -9.90263 -0.52268 16 2 -8.43128 -11.58660 -1.12089 16 3 -8.96514 -12.17374 -1.37194 16 4 -9.60600 -14.56057 -2.64723 16 5 -10.16978 -15.98977 -3.50891 16 6 -10.35639 -18.71745 -5.20791 16 7 -10.53706 NUMXQ(K)= 7 2.610E-04 0.079 1.000 2.190E-04 0.237 3.000 1.825E-04 0.395 5.000 1.390E-04 0.791 10.000 1.150E-04 1.186 15.000 9.859E-05 1.581 20.000 8.707E-05 1.976 25.000 7.843E-05 2.372 30.000

LR-N23-0050 LAR S23-04 LAR H23-02

- 117 -

7.162E-05 2.767 35.000 6.493E-05 3.162 40.000 5.643E-05 3.557 45.000 4.966E-05 3.953 50.000 4.413E-05 4.348 55.000 3.955E-05 4.743 60.000 3.489E-05 5.138 65.000 3.019E-05 5.534 70.000 1.668E-04 0.5 6.33 ANNUAL AVERAGE = 2.28E-06 K= 16 FIVEXQ(K)= 1.668E-04 FIVEPR(K)= 6.325

LR-N23-0050 LAR S23-04 LAR H23-02

- 118 -

USNRC COMPUTER CODE-PAVAN, VERSION 2.0 RUN DATE: 03-03-2023 PLANT NAME: SGS EAB METEOROLOGICAL INSTRUMENTATION DATA PERIOD: 2019-2021 WIND SENSORS HEIGHT: 10 m TYPE OF RELEASE: Ground Level DELTA-T HEIGHTS: 10 m - 46 m SOURCE OF DATA: A-5-ZZ-MDC-2391 COMMENTS: 695 m and 790 m EAB PROGRAM: PAVAN, 10/76, 8/79 REVISION, IMPLEMENTATION OF REGULATORY GUIDE 1.145 LOW POPULATION ZONE CALCULATIONS:

DIRECTION-INDEPENDENT (S.R.P 2.3.4) MODEL.

MINIMUM BOUNDARY DISTANCE = 790.0 METERS.

BUILDING WAKE CREDIT ALLOWED: C= 0.5 A= 2399. D= 58.3 BELOW ARE PRINTED THE ORDERED VALUES OF CHI/Q AND THE FREQUENCY WITH WHICH THAT VALUE IS REACHED OR EXCEEDED.

THE TOP NUMBER IS THE CHI/Q. THE MIDDLE NUMBER IS THE FREQUENCY NORMALIZED TO THIS SECTOR.

THE THIRD NUMBER IS THE FREQUENCY WITH RESPECT TO ALL TIME.

1.378E-03 8.726E-04 6.564E-04 5.453E-04 4.447E-04 4.155E-04 3.362E-04 3.211E-04 2.815E-04 2.597E-04 0.004 0.032 0.324 0.332 1.145 1.745 2.582 2.602 3.947 4.895 0.00400 0.03202 0.32421 0.33221 1.14473 1.74512 2.58165 2.60167 3.94653 4.89513 2.260E-04 2.128E-04 1.759E-04 1.702E-04 1.529E-04 1.431E-04 1.371E-04 1.365E-04 1.330E-04 1.139E-04 6.732 8.714 11.103 12.080 12.416 17.359 17.363 17.811 22.126 22.422 6.73231 8.71358 11.10311 12.07973 12.41595 17.35911 17.36311 17.81140 22.12616 22.42235 1.077E-04 1.036E-04 8.940E-05 8.640E-05 8.562E-05 7.831E-05 7.212E-05 6.892E-05 6.732E-05 6.528E-05 24.712 25.805 36.615 37.368 37.616 39.601 40.066 40.142 48.287 48.319 24.71181 25.80451 36.61543 37.36792 37.61607 39.60135 40.06564 40.14169 48.28691 48.31893 6.339E-05 5.420E-05 5.399E-05 5.263E-05 4.595E-05 4.507E-05 4.422E-05 4.363E-05 3.964E-05 3.387E-05 48.327 48.707 53.690 59.342 59.358 61.768 61.864 61.984 67.323 68.908 48.32693 48.70718 53.69036 59.34198 59.35799 61.76753 61.86359 61.98367 67.32309 68.90810 3.344E-05 3.179E-05 3.019E-05 2.909E-05 2.727E-05 2.653E-05 2.247E-05 2.045E-05 1.994E-05 1.818E-05 69.076 73.639 73.667 73.727 74.011 77.406 78.298 78.374 81.712 81.748 69.07621 73.63913 73.66714 73.72718 74.01136 77.40553 78.29810 78.37415 81.71229 81.74831 1.693E-05 1.605E-05 1.546E-05 1.357E-05 1.133E-05 1.070E-05 1.039E-05 8.515E-06 7.826E-06 6.913E-06 82.473 83.049 83.165 83.930 84.442 84.618 85.138 85.667 86.259 86.351 82.47278 83.04915 83.16522 83.92971 84.44204 84.61815 85.13848 85.66682 86.25919 86.35125

LR-N23-0050 LAR S23-04 LAR H23-02

- 119 -

6.855E-06 6.277E-06 5.239E-06 4.683E-06 4.570E-06 3.937E-06 3.541E-06 3.170E-06 2.380E-06 2.113E-06 86.455 86.964 87.464 87.740 87.764 88.381 88.845 89.013 90.582 90.606 86.45531 86.96364 87.46396 87.74014 87.76415 88.38055 88.84484 89.01295 90.58195 90.60597 1.792E-06 1.437E-06 1.200E-06 9.017E-07 7.259E-07 4.839E-07 92.703 95.001 96.986 99.115 99.844 100.000 92.70332 95.00079 96.98605 99.11542 99.84389 99.99998 X/Q PERCENTILES (BASED ON THE UPPER ENVELOPE OF THE ORDERED X/Q-FREQUENCY VALUES, AND AS PLOTTED ON A LOG-NORMAL GRAPH.)

PERCENT OF TIME CHI/Q IS EQUALED OR EXCEEDED CHI/Q WITH RESPECT TO WHEN THE WIND BLOWS SEC/CUBIC METER THE TOTAL TIME INTO THIS SECTOR ONLY 4.885E-04 1.000 1.000 3.389E-04 3.000 3.000 2.747E-04 5.000 5.000 2.002E-04 10.000 10.000 1.647E-04 15.000 15.000 1.410E-04 20.000 20.000 1.219E-04 25.000 25.000 1.060E-04 30.000 30.000 9.308E-05 35.000 35.000 8.218E-05 40.000 40.000 7.281E-05 45.000 45.000 6.482E-05 50.000 50.000 5.803E-05 55.000 55.000 5.151E-05 60.000 60.000 4.354E-05 65.000 65.000 3.647E-05 70.000 70.000 2.983E-05 75.000 75.000 2.747E-04 5.0 5.00 K= 17 FIVEXQ(K)= 2.747E-04 FIVEPR(K)= 5.000

LR-N23-0050 LAR S23-04 LAR H23-02

- 120 -

USNRC COMPUTER CODE-PAVAN, VERSION 2.0 RUN DATE: 03-03-2023 PLANT NAME: SGS EAB METEOROLOGICAL INSTRUMENTATION DATA PERIOD: 2019-2021 WIND SENSORS HEIGHT: 10 m TYPE OF RELEASE: Ground Level DELTA-T HEIGHTS: 10 m - 46 m SOURCE OF DATA: A-5-ZZ-MDC-2391 COMMENTS: 695 m and 790 m EAB PROGRAM: PAVAN, 10/76, 8/79 REVISION, IMPLEMENTATION OF REGULATORY GUIDE 1.145 LOW POPULATION ZONE CALCULATIONS:

FIVE PERCENT OVERALL SITE LIMIT BUILDING WAKE CREDIT ALLOWED: C= 0.5 A= 2399. D= 58.3 BELOW ARE PRINTED THE ORDERED VALUES OF CHI/Q AND THE FREQUENCY WITH WHICH THAT VALUE IS REACHED OR EXCEEDED.

THE TOP NUMBER IS THE CHI/Q. THE MIDDLE NUMBER IS THE FREQUENCY NORMALIZED TO THIS SECTOR.

THE THIRD NUMBER IS THE FREQUENCY WITH RESPECT TO ALL TIME.

6.893E-04 4.577E-04 3.282E-04 2.701E-04 2.249E-04 2.224E-04 2.179E-04 1.988E-04 1.750E-04 1.702E-04 0.004 0.032 0.324 0.332 2.169 2.982 3.582 3.602 4.439 5.415 0.00400 0.03202 0.32421 0.33221 2.16939 2.98191 3.58229 3.60231 4.43884 5.41547 1.476E-04 1.371E-04 1.365E-04 1.286E-04 1.278E-04 1.152E-04 1.139E-04 1.077E-04 9.468E-05 8.713E-05 6.760 6.764 7.213 8.161 13.104 15.086 15.382 17.671 18.008 20.397 6.76033 6.76433 7.21262 8.16123 13.10439 15.08567 15.38186 17.67132 18.00753 20.39706 8.640E-05 8.562E-05 7.212E-05 6.892E-05 6.753E-05 6.753E-05 6.732E-05 6.528E-05 6.414E-05 6.339E-05 21.150 21.398 21.862 21.938 32.749 37.064 45.209 45.241 46.334 46.342 21.14953 21.39769 21.86198 21.93803 32.74895 37.06372 45.20894 45.24095 46.33364 46.34164 5.420E-05 5.399E-05 4.926E-05 4.595E-05 4.507E-05 4.422E-05 4.363E-05 4.254E-05 3.831E-05 3.387E-05 46.722 51.705 53.690 53.706 56.116 56.212 56.332 61.984 67.323 68.908 46.72188 51.70507 53.69035 53.70636 56.11589 56.21194 56.33202 61.98363 67.32306 68.90808 3.344E-05 3.179E-05 3.019E-05 2.909E-05 2.727E-05 2.653E-05 2.247E-05 2.045E-05 1.994E-05 1.818E-05 69.076 73.639 73.667 73.727 74.011 77.406 78.298 78.374 81.712 81.748 69.07619 73.63912 73.66714 73.72718 74.01135 77.40553 78.29810 78.37415 81.71227 81.74830 1.693E-05 1.605E-05 1.546E-05 1.357E-05 1.133E-05 1.070E-05 1.039E-05 8.515E-06 7.826E-06 6.913E-06 82.473 83.049 83.165 83.930 84.442 84.618 85.138 85.667 86.259 86.351 82.47276 83.04913 83.16520 83.92970 84.44202 84.61813 85.13845 85.66679 86.25916 86.35123

LR-N23-0050 LAR S23-04 LAR H23-02

- 121 -

6.855E-06 6.277E-06 5.239E-06 4.683E-06 4.570E-06 3.937E-06 3.541E-06 3.170E-06 2.380E-06 2.113E-06 86.455 86.964 87.464 87.740 87.764 88.381 88.845 89.013 90.582 90.606 86.45529 86.96360 87.46393 87.74010 87.76412 88.38050 88.84480 89.01290 90.58189 90.60591 1.792E-06 1.437E-06 1.200E-06 9.017E-07 7.259E-07 4.839E-07 92.703 95.001 96.986 99.115 99.844 100.000 92.70326 95.00072 96.98599 99.11535 99.84383 99.99992 X/Q PERCENTILES (BASED ON THE UPPER ENVELOPE OF THE ORDERED X/Q-FREQUENCY VALUES, AND AS PLOTTED ON A LOG-NORMAL GRAPH.)

PERCENT OF TIME CHI/Q IS EQUALED OR EXCEEDED CHI/Q WITH RESPECT TO WHEN THE WIND BLOWS SEC/CUBIC METER THE TOTAL TIME INTO THIS SECTOR ONLY K I XQSAVE(K,I) XQINT(K,I) XQSLOP(K,I) 18 1 -7.27981 -9.39961 -0.53743 18 2 -8.43128 -9.84535 -0.78482 18 3 -8.96514 -9.95395 -0.88165 18 4 -9.13588 -9.67591 -0.58200 18 5 -9.60600 -9.76886 -1.35589 18 6 -9.82667 -9.79062 -0.84554 18 7 -10.16978 -9.71377 -1.01691 18 8 -10.35639 NUMXQ(K)= 8 2.890E-04 1.000 1.000 2.274E-04 3.000 3.000 1.927E-04 5.000 5.000 1.449E-04 10.000 10.000 1.186E-04 15.000 15.000 1.024E-04 20.000 20.000 9.294E-05 25.000 25.000 8.516E-05 30.000 30.000 7.854E-05 35.000 35.000 7.273E-05 40.000 40.000 6.753E-05 45.000 45.000 5.721E-05 50.000 50.000 5.034E-05 55.000 55.000

LR-N23-0050 LAR S23-04 LAR H23-02

- 122 -

4.520E-05 60.000 60.000 4.043E-05 65.000 65.000 3.548E-05 70.000 70.000 1.927E-04 5.0 5.00 K= 18 FIVEXQ(K)= 1.927E-04 FIVEPR(K)= 5.000 K HIGHPR PR GRNDVT(K) 1 -2.62223 0.43679 6.39209 2 -2.57624 0.49942 6.15594 3 -2.61804 0.44219 5.86375 4 -2.67971 0.36843 4.02257 5 -2.68577 0.36182 3.23807 6 -2.65724 0.39392 3.26609 7 -2.62971 0.42729 9.61015 8 -2.82380 0.23729 6.59222 9 -2.90887 0.18137 5.84374 10 -2.96884 0.14947 5.78770 11 -2.85344 0.21625 6.07189 12 -3.03146 0.12169 6.04387 13 -3.02383 0.12480 5.85575 14 -3.09570 0.09818 6.42811 15 -2.79165 0.26221 10.92299 16 -2.72434 0.32216 7.90506 K HOURS(K) TOTHRS 1 38.26282 38.26282 2 43.74876 82.01158 3 38.73595 120.74754 4 32.27448 153.02200 5 31.69528 184.71729 6 34.50716 219.22446 7 37.43090 256.65536 8 20.78687 277.44223 9 15.88827 293.33051 10 13.09373 306.42422 11 18.94376 325.36798 12 10.66039 336.02838 13 10.93283 346.96121 14 8.60064 355.56186

LR-N23-0050 LAR S23-04 LAR H23-02

- 123 -

15 22.96951 378.53137 16 28.22090 406.75226 K FIVEXQ SVANN SLTIME TIMINT I TIME XQT 1 1.879E-04 2.318E-06 -0.5242 -8.2161 1 8.0 -9.30615 2 16.0 -9.66949 3 72.0 -10.45793 4 624.0 -11.58992 2 1.969E-04 2.312E-06 -0.5300 -8.1655 1 8.0 -9.26769 2 16.0 -9.63508 3 72.0 -10.43230 4 624.0 -11.57690 3 1.852E-04 2.293E-06 -0.5237 -8.2309 1 8.0 -9.32000 2 16.0 -9.68303 3 72.0 -10.47077 4 624.0 -11.60178 4 1.688E-04 1.904E-06 -0.5348 -8.3163 1 8.0 -9.42848 2 16.0 -9.79921 3 72.0 -10.60366 4 624.0 -11.75866 5 1.646E-04 1.702E-06 -0.5452 -8.3340 1 8.0 -9.46776 2 16.0 -9.84566 3 72.0 -10.66570 4 624.0 -11.84306 6 1.736E-04 1.461E-06 -0.5698 -8.2639 1 8.0 -9.44874 2 16.0 -9.84370 3 72.0 -10.70072 4 624.0 -11.93120 7 1.855E-04 2.439E-06 -0.5166 -8.2342 1 8.0 -9.30845 2 16.0 -9.66654 3 72.0 -10.44356 4 624.0 -11.55917 8 1.477E-04 1.822E-06 -0.5242 -8.4569 1 8.0 -9.54690

LR-N23-0050 LAR S23-04 LAR H23-02

- 124 -

2 16.0 -9.91025 3 72.0 -10.69870 4 624.0 -11.83070 9 1.212E-04 1.688E-06 -0.5097 -8.6645 1 8.0 -9.72442 2 16.0 -10.07774 3 72.0 -10.84443 4 624.0 -11.94520 10 1.243E-04 1.882E-06 -0.4998 -8.6463 1 8.0 -9.68554 2 16.0 -10.03196 3 72.0 -10.78366 4 624.0 -11.86292 11 1.461E-04 2.074E-06 -0.5075 -8.4791 1 8.0 -9.53440 2 16.0 -9.88616 3 72.0 -10.64944 4 624.0 -11.74534 12 1.294E-04 1.837E-06 -0.5075 -8.6007 1 8.0 -9.65592 2 16.0 -10.00767 3 72.0 -10.77095 4 624.0 -11.86683 13 1.195E-04 1.656E-06 -0.5104 -8.6781 1 8.0 -9.73933 2 16.0 -10.09309 3 72.0 -10.86072 4 624.0 -11.96285 14 1.203E-04 1.717E-06 -0.5068 -8.6742 1 8.0 -9.72803 2 16.0 -10.07931 3 72.0 -10.84155 4 624.0 -11.93594 15 1.637E-04 2.718E-06 -0.4887 -8.3790 1 8.0 -9.39520 2 16.0 -9.73395 3 72.0 -10.46900 4 624.0 -11.52436 16 1.668E-04 2.280E-06 -0.5119 -8.3441 1 8.0 -9.40855 2 16.0 -9.76336

LR-N23-0050 LAR S23-04 LAR H23-02

- 125 -

3 72.0 -10.53329 4 624.0 -11.63872 17 2.747E-04 2.718E-06 -0.5505 -7.8184 1 8.0 -8.96301 2 16.0 -9.34456 3 72.0 -10.17250 4 624.0 -11.36121 18 1.927E-04 2.718E-06 -0.5082 -8.2019 1 8.0 -9.25868 2 16.0 -9.61095 3 72.0 -10.37535 4 624.0 -11.47283

LR-N23-0050 LAR S23-04 LAR H23-02

- 126 -

USNRC COMPUTER CODE-PAVAN, VERSION 2.0 RUN DATE: 03-03-2023 PLANT NAME: SGS EAB METEOROLOGICAL INSTRUMENTATION DATA PERIOD: 2019-2021 WIND SENSORS HEIGHT: 10 m TYPE OF RELEASE: Ground Level DELTA-T HEIGHTS: 10 m - 46 m SOURCE OF DATA: A-5-ZZ-MDC-2391 COMMENTS: 695 m and 790 m EAB PROGRAM: PAVAN, 10/76, 8/79 REVISION, IMPLEMENTATION OF REGULATORY GUIDE 1.145 RELATIVE CONCENTRATION (X/Q) VALUES (SEC/CUBIC METER)

VERSUS HOURS PER YEAR MAX AVERAGING TIME 0-2 HR X/Q IS DOWNWIND DISTANCE EXCEEDED DOWNWIND SECTOR (METERS) 0-2 HOURS 0-8 HOURS 8-24 HOURS 1-4 DAYS 4-30 DAYS ANNUAL AVERAGE IN SECTOR SECTOR S 790. 1.88E-04 9.09E-05 6.32E-05 2.87E-05 9.26E-06 2.32E-06 38.3 S SSW 790. 1.97E-04 9.44E-05 6.54E-05 2.95E-05 9.38E-06 2.31E-06 43.7 SSW SW 790. 1.85E-04 8.96E-05 6.23E-05 2.84E-05 9.15E-06 2.29E-06 38.7 SW WSW 790. 1.69E-04 8.04E-05 5.55E-05 2.48E-05 7.82E-06 1.90E-06 32.3 WSW W 790. 1.65E-04 7.73E-05 5.30E-05 2.33E-05 7.19E-06 1.70E-06 31.7 W WNW 790. 1.74E-04 7.88E-05 5.31E-05 2.25E-05 6.58E-06 1.46E-06 34.5 WNW NW 790. 1.86E-04 9.07E-05 6.34E-05 2.91E-05 9.55E-06 2.44E-06 37.4 NW NNW 790. 1.48E-04 7.14E-05 4.97E-05 2.26E-05 7.28E-06 1.82E-06 20.8 NNW N 790. 1.21E-04 5.98E-05 4.20E-05 1.95E-05 6.49E-06 1.69E-06 15.9 N NNE 790. 1.24E-04 6.22E-05 4.40E-05 2.07E-05 7.05E-06 1.88E-06 13.1 NNE NE 790. 1.46E-04 7.23E-05 5.09E-05 2.37E-05 7.93E-06 2.07E-06 18.9 NE ENE 790. 1.29E-04 6.40E-05 4.51E-05 2.10E-05 7.02E-06 1.84E-06 10.7 ENE E 790. 1.20E-04 5.89E-05 4.14E-05 1.92E-05 6.38E-06 1.66E-06 10.9 E ESE 790. 1.20E-04 5.96E-05 4.19E-05 1.96E-05 6.55E-06 1.72E-06 8.6 ESE SE 790. 1.64E-04 8.31E-05 5.92E-05 2.84E-05 9.89E-06 2.72E-06 23.0 SE SSE 790. 1.67E-04 8.20E-05 5.75E-05 2.66E-05 8.82E-06 2.28E-06 28.2 SSE MAX X/Q 1.97E-04 TOTAL HOURS AROUND SITE: 406.8 SRP 2.3.4 790. 2.75E-04 1.28E-04 8.74E-05 3.82E-05 1.16E-05 2.72E-06 SITE LIMIT 1.93E-04 9.53E-05 6.70E-05 3.12E-05 1.04E-05 2.72E-06 0.5 PERCENT X/Q TO AN INDIVIDUAL IS LIMITING.

    • NOTE**: VALUES ON THIS PAGE ARE APPROXIMATIONS ONLY.

CHECK THE REASONABLENESS OF THE ENVELOPES COMPUTED FOR THE 0-2 HOUR VALUES. FOR ANY FAULTY ENVELOPES, ADJUST THE ABOVE VALUES.