WSES-FSAR-UNIT-3 9-i Revision 306 (05/12)
CHAPTER 9 AUXILIARY SYSTEMS TABLE OF CONTENTS Section Title Page 9.0 AUXILIARY SYSTEMS 9.1-1 9.1 FUEL STORAGE AND HANDLING 9.1-1 9.1.1 NEW FUEL STORAGE 9.1-1 (EC-14275, R306) 9.1.2 SPENT FUEL STORAGE IN THE FUEL HANDLING AND 9.1-4 CONTAINMENT BUILDINGS (EC-14275, R306) 9.1.3 FUEL POOL SYSTEM (SPENT FUEL POOL COOLING AND 9.1-8 CLEANUP SYSTEM) 9.1.4 FUEL HANDLING SYSTEM 9.1-15 (EC-14275, R306) 9.1.5 SPENT FUEL DRY CASK STORAGE 9.1-40 (EC-14275, R306) 9.2 WATER SYSTEMS 9.2-1 9.2.1 STATION SERVICE WATER SYSTEM 9.2-1 9.2.2 COOLING SYSTEM FOR REACTOR AUXILIARIES 9.2-1 9.2.3 DEMINERALIZED WATER MAKEUP SYSTEM 9.2-6 (DRN 00-691, R11-A) 9.2.4 POTABLE AND SANITARY WATER SYSTEM 9.2-11 9.2.5 ULTIMATE HEAT SINK 9.2-12 9.2.6 CONDENSATE STORAGE FACILITIES 9.2-18 (DRN 00-691, R11-A) 9.2.7 TURBINE CLOSED COOLING WATER SYSTEM 9.2-20 (DRN 00-691, R11-A) 9.2.8 PRIMARY WATER STORAGE FACILITIES 9.2-22 (DRN 00-691, R11-A) 9.2.9 ESSENTIAL SERVICES CHILLED WATER SYSTEM 9.2-24 9.3 PROCESS AUXILIARIES 9.3-1 9.3.1 COMPRESSED AIR SYSTEM 9.3-1 (DRN 00-691, R11-A) 9.3.2 PROCESS SAMPLING SYSTEM 9.3-3 (DRN 00-691, R11-A) 9.3.3 EQUIPMENT AND FLOOR DRAINAGE SYSTEMS 9.3-8 (DRN 00-691, R11-A) 9.3.4 CHEMICAL AND VOLUME CONTROL SYSTEM 9.3-15 9.3.5 STANDBY LIQUID CONTROL SYSTEM (BWRs) 9.3-38 (DRN 00-691, R11-A)
WSES-FSAR-UNIT-3 9-ii Revision 11-A (02/02)
CHAPTER 9 TABLE OF CONTENTS (Cont'd)
Section Title Page (DRN 00-691, R11-A) 9.3.6 SHUTDOWN COOLING SYSTEM (RESIDUAL HEAT REMOVAL 9.3-38 SYSTEM) 9.3.7 HYDROGEN SYSTEM 9.3-50 9.3.8 POST ACCIDENT SAMPLING SYSTEM 9.3-52 9.3.9 NITROGEN SYSTEM 9.3-56
9.3 REFERENCES
9.3-59 (DRN 00-691, R11-A) 9.4 AIR CONDITIONING, HEATING, COOLING AND VENTILATION 9.4-1 SYSTEMS 9.4.1 CONTROL ROOM AIR CONDITIONING SYSTEM 9.4-1 9.4.2 FUEL HANDLING BUILDING VENTILATION SYSTEM 9.4-4 9.4.3 REACTOR AUXILIARY BUILDING VENTILATION SYSTEM 9.4-8 (DRN 00-691, R11-A) 9.4.4 TURBINE BUILDING VENTILATION SYSTEM 9.4-24 9.4.5 REACTOR BUILDING VENTILATION SYSTEM 9.4-25 9.5 OTHER AUXILIARY SYSTEMS 9.5-1 (DRN 00-691, R11-A) 9.5.1 FIRE PROTECTION SYSTEM 9.5-1 9.5.2 COMMUNICATION SYSTEMS 9.5-246 9.5.3 LIGHTING SYSTEMS 9.5-251 9.5.4 DIESEL GENERATOR FUEL OIL STORAGE AND TRANSFER 9.5-252 SYSTEMS 9.5.5 DIESEL GENERATOR JACKET WATER COOLING SYSTEM 9.5-255 9.5.6 DIESEL ENGINE STARTING SYSTEM 9.5-258 9.5.7 DIESEL GENERATOR LUBRICATION SYSTEM 9.5-260 9.5.8 DIESEL GENERATOR COMBUSTION AIR INTAKE AND EXHAUST 9.5-263 SYSTEM
WSES-FSAR-UNIT-3 9-iii Revision 15 (03/07)
CHAPTER 9 AUXILIARY SYSTEMS LIST OF TABLES Table Title 9.1-1 Fuel Pool System Process Flow Data 9.1-2 Refueling and Spent Fuel Pool Water Chemistry 9.1-3 Principal Components Design Data Summary 9.1-4 Failure Mode and Effects Analysis Fuel Pool System 9.1-5 Major Tools and Servicing Equipment Required for Refueling Functions 9.1-6 Reactor Building Crane Data 9.1-7 FHB Building Crane Data (Cask Crane)
(DRN 99-0971) 9.1-8 Fuel Assembly Parameters used in Criticality Analysis (DRN 99-0971) 9.2-1 Design Data for the Component Cooling Water System and Auxiliary Component Cooling Water System Components 9.2-2 CCWS and ACCWS Temperature and Flow Control Description 9.2-3 Heat Removal and Water Requirements for the CCWS 9.2-4 Failure Modes and Effects Analysis for the CCWS and ACCWS Post LOCA 9.2-5 CCWS and ACCWS Instrument Application 9.2-6 Design Data for PWTP Components (DRN 06-873, R15) 9.2-7 DELETED (DRN 06-873, R15) 9.2-8 Principal Cooling Tower Components Dry Cooling Towers (DRN 00-691, R11-A) 9.2-9 Estimated Wet-Dry Cooling Tower Heat Dissipation for all Operations 9.2-10 Water Requirements for Wet Cooling Towers Post LOCA Essential Loads (DRN 00-691, R11-A) 9.2-11 Cooling Tower Instrument Application 9.2-12 Design Data for Condensate Storage System 9.2-13 Design Data for Turbine Closed Cooling Water System Components 9.2-14 Turbine Plant Operating Flow Rates and Calculated Heat Loads
WSES-FSAR-UNIT-3 9-iv Revision 11-A (02/02)
CHAPTER 9 AUXILIARY SYSTEMS LIST OF TABLES (Cont'd)
Table Title 9.2-15 Design Data for Primary Water Storage System 9.2-16 Safety Related and Nonsafety Related Air Handling Units 9.2-17 Essential Services Chilled Water System Failure Mode and Effects Analysis (DRN 00-691, R11-A) 9.3-1a Safety Class Valves with Air Accumulators (DRN 00-691, R11-A) 9.3-1b Safety Class Valves with Nitrogen Accumulators 9.3-2 Design Data for Compressed Air System Components 9.3-3 Primary Sample Points 9.3-4 Secondary Sample Points 9.3-5 Sub-system Construction Materials 9.3-6 Decontamination Areas 9.3-7 Reactor Coolant and Reactor Makeup Water Chemistry 9.3-8 CVCS Design Transients (DRN 00-691, R11-A) 9.3-9 Principal Component Design Data Summary (DRN 00-691, R11-A) 9.3-10 DELETED 9.3-11 Chemical and Volume Control System Process Parameters 9.3-12 Schedule of Waste Generation 9.3-13 Chemical and Volume Control System Process Flow Data 9.3-14 CVCS Component Diesel Loading 9.3-15 Chemical and Volume Control System (Boron Addition Portion) Failure Mode and Effects Analysis 9.3-16 Shutdown Cooling System (SDCS) Failure Mode and Effects Analysis 9.3-17 Shutdown Cooling Heat Exchanger Data 9.3-18 Shutdown Cooling System Valves Design Pressures and Temperatures
WSES-FSAR-UNIT-3 9-v Revision 11-A (02/02)
CHAPTER 9 AUXILIARY SYSTEMS LIST OF TABLES (Cont'd)
Table Title 9.3-19 DELETED 9.3-20 Required Valve Actuations Accomplished from the Main Control Room 9.3-21 Design and Materials Data for Bulk Gas Storage Tubes (DRN 00-703, R11-A) 9.3-21A Design and Materials Data for Essential Air Accumulators (DRN 00-703, R11-A) 9.3-22 Shutdown Cooling System Relief Valve Parameters 9.4-1 Design Space Temperatures and Humidities for Normal Plant Operation 9.4-2 Design Data for Control Room Air Conditioning System Components 9.4-3 Control Room Air Conditioning System Failure Modes and Effects Analysis 9.4-4 Design Data for Fuel Handling Building Ventilation System 9.4-5 F.H.B. Ventilation System Failure Modes and Effects Analysis 9.4-6 Design Data for Reactor Auxiliary Building Normal Ventilation System 9.4-7 Design Data for Personnel Decontamination Area Ventilation System 9.4-8 Design Data for Emergency Diesel Generator Ventilation System 9.4-9 Design Data for RAB H&V Room Ventilation System 9.4-10 Design Data for RAB Cable Vault and Switchgear Areas Ventilation System 9.4-11 RAB Cable Vault and Switchgear Areas Ventilation System Failure Modes and Effects Analysis 9.4-12 Design Data for RAB Hot Machine Shop and Decontamination Area Ventilation System 9.4-13 Design Data for RAB Air Conditioning System 9.4-14 Design Data for Controlled Ventilation Area Systems (CVAS) Fan Coolers 9.4-15 Design Data for Turbine Building Ventilation System
WSES-FSAR-UNIT-3 9-vi Revision 11-A (02/02)
CHAPTER 9 AUXILIARY SYSTEMS LIST OF TABLES (Cont'd)
Table Title 9.4-16 Design Data for Airborne Radioactivity Removal System 9.4-17 Design Data for Containment Atmosphere Purge System 9.4-18 Design Data for Reactor Cavity Cooling System 9.4-19 Design Data for Control Element Drive Mechanism (CEDM) Cooling System 9.4-20 Design Data for Annulus Negative Pressure System (ANPS) 9.4-21 Comparison of Normal Ventilation System Air Cleaning Unit with Regulatory Guide 1.140 (March 1978) 9.5-1 Design Data - Diesel Generator Fuel Oil Storage and Transfer System 9.5-2 Diesel Generator Fuel Oil Storage and Transfer Systems Failure Mode and Effects Analysis 9.5-3 Design Parameters for Diesel Generator Jacket Cooling Water System 9.5-4 Design Data - Diesel Engine Starting System Components (DRN 00-691, R11-A) 9.5-5 Design Parameters for Diesel Generator Lube Oil System Components (DRN 00-691, R11-A) 9.5-6 Summary of Onsite Communication System Capabilities and Noise Consideration During Transients and/or Accidents 9.5.1-1 Tabulation of Doors which are Located Within Fire Walls 9.5.1-2 Fire Protection System Failure Mode and Effects Analysis 9.5.1-3 Fire Areas/Zones (DRN 00-691, R11-A) 9.5.1-4 Minimum Equipment Requirement for Safe Plant Shutdown Following a Cable Vault and Control Room Fire (DRN 00-691, R11-A)
WSES-FSAR-UNIT-3 9-vii Revision 11-A (02/02)
CHAPTER 9 AUXILIARY SYSTEMS LIST OF FIGURES Figure Title (DRN 00-691, R11-A) 9.1-1 New Fuel Storage Racks (DRN 00-691, R11-A) 9.1-2 Spent Fuel Pit Liner (Sheet 1 of 2) 9.1-2 Spent Fuel Pit Liner (Sheet 2 of 2)
(DRN 00-691, R11-A) 9.1-3 Plan Arrangement of Spent Fuel Pool Storage Racks (Sheet 1 of 3)
(DRN 00-691, R11-A) 9.1-3 Rack Assembly - Type 64-1 thru 64-12 (Sheet 2 of 3) 9.1-3 Rack Assembly - Type 80-1 thru 80-4 (Sheet 3 of 3)
(DRN 01-419) 9.1-4 Flow Diagram Fuel Pool System (DRN 01-419) 9.1-5 Fuel Handling Equipment Arrangement (Typical) 9.1-6 Dual-Masted Refueling Machine 9.1-7 Fuel Handling Tools 9.1-8 Reactor Vessel Head Lift Rig 9.1-9 Core Support Barrel Lift Rig 9.1-10 Upper Guide Structure Lift Rig 9.1-11 Spent fuel Handling Machine 9.1-12 New Fuel Elevator 9.1-13 Underwater TV System 9.1-14 Deleted 9.1-15 Deleted 9.1-16 Hydraulic Power Unit 9.1-17 Refueling Pool Seals 9.1-18 Fuel Handling Building Crane Clearance Diagram (Plan) 9.1-19 Fuel Handling Building Cane Clearance Diagram (Section) 9.1-20 Reactor Building - Reactor Bridge Crane Clearance 9.1-21 Spent Fuel Pool Cooling System - Thermal Performance for Maximum Heat Load 9.1.22 Spent Fuel Pool Cooling System - Thermal Performance for Normal Head Load
WSES-FSAR-UNIT-3 9-viii Revision 11 (05/01)
CHAPTER 9 AUXILIARY SYSTEMS LIST OF FIGURES (Cont'd)
Figure Title 9.2-1 Flow Diagram - Component Closed Cooling Water System (Sheet 1 of 6) 9.2-1 Flow Diagram - Component Closed Cooling Water System (Sheet 2 of 6) 9.2-1 Flow Diagram - Component Closed Cooling Water System (Sheet 3 of 6)
(DRN 01-419) 9.2-1 Flow Diagram - Component Closed Cooling Water System (Sheet 4 of 6)
(DRN 01-419) 9.2-1 Flow Diagram - Component Closed Cooling Water System (Sheet 5 of 6)
(DRN 01-419) 9.2-1 Flow Diagram - Component Closed Cooling Water System (Sheet 6 of 6)
(DRN 01-419) 9.2-2 Flow Diagram - Primary Water, Condensate Storage and Makeup Demineralizer (Sheet 1 of 3) 9.2-2 Flow Diagram - Primary Water, Condensate Storage and Makeup Demineralizer (Sheet 2 of 3) 9.2-2 Flow Diagram - Primary Water, Condensate Storage and Makeup Demineralizer (Sheet 3 of 3) 9.2-3 DELETED (3 SHEETS) 9.2-4 Heat Load Dissipation of Ultimate Heat Sink After LOCA 9.2-4a Wet Cooling Tower Integrated Heat Load Curve After LOCA 9.2-5 Heat Removal Capacity of Dry Cooling Tower vs. Dry Bulb Temperature 9.2-5a Ultimate Heat Sink Design Basis Meteorological Conditions 9.2-6 Simplified Flow Diagram of Wet and Dry Cooling Towers 9.2-7 Turbine Building Closed Cooling Water System (Sheet 1 of 2) 9.2-7 Turbine Building Closed Cooling Water System (Sheet 2 of 2) 9.2-8 Essential Services Chilled Water System (Sheet 1 of 3) 9.2-8 Essential Services Chilled Water System (Sheet 2 of 3)
(DRN 01-419) 9.2-8 Essential Services Chilled Water System ( Sheet 3 of 3)
(DRN 01-419) 9.2-9 Flow Diagram - Potable Water System
WSES-FSAR-UNIT-3 9-ix Revision 11-A (02/02)
CHAPTER 9 AUXILIARY SYSTEMS LIST OF FIGURES (Cont'd)
Figure Title 9.3-1 Flow Diagram - Service and Instrument Air Systems (Sheet 1 of 9) 9.3-1 Flow Diagram - Service and Instrument Air Systems (Sheet 2 of 9)
(DRN 01-419) 9.3-1 Flow Diagram - Service and Instrument Air Systems (Sheet 3 of 9) 9.3-1 Flow Diagram - Service and Instrument Air Systems (Sheet 4 of 9)
(DRN 01-419) 9.3-1 Flow Diagram - Service and Instrument Air Systems (Sheet 5 of 9) 9.3-1 Flow Diagram - Service and Instrument Air Systems (Sheet 6 of 9) 9.3-1 Flow Diagram - Service and Instrument Air Systems (Sheet 7 of 9) 9.3-1 Flow Diagram - Service and Instrument Air Systems (Sheet 8 of 9) 9.3-1 Flow Diagram - Service and Instrument Air Systems (Sheet 9 of 9) 9.3-2 Flow Diagram Sampling System (Sheet 1 of 6) 9.3-2 Flow Diagram Sampling System (Sheet 2 of 6)
(DRN 01-419) 9.3-2 Flow Diagram Sampling System (Sheet 3 of 6)
(DRN 00-691, R11-A) 9.3-2 Flow Diagram Post Accident Sampling System (Sheet 4 of 6)
(DRN 00-691, R11-A) 9.3-2 Flow Diagram Waste Gas Analyzer System (Sheet 5 of 6) 9.3-2 Flow Diagram Sampling System (Sheet 6 of 6)
(DRN 01-419) 9.3-3 Flow Diagram - Sump Pump Systems Turbine Building and Yard (Sheet 1 of 3)
(DRN 01-419) 9.3-3 Flow Diagram - Sump Pump Systems Reactor Auxiliary Building (Sheet 2 of 3) 9.3-3 Flow Diagram - Sump Pump Systems Reactor Building, Fuel Handling Building, Cooling Tower Area and Intake Structure (Sheet 3 of 3) 9.3-4 Reactor, Turbine and Fuel Handling Building Drainage Systems 9.3-5 Reactor Auxiliary Building Drainage Systems (DRN 01-419) 9.3-6 Flow Diagram Chemical and Volume Control System (Sheet 1 of 3)
(DRN 01-419) 9.3-6 Flow Diagram Chemical and Volume Control System (Sheet 2 of 3) 9.3-6 Flow Diagram Chemical and Volume Control System (Sheet 3 of 3) 9.3-7 Normal Cooldown All System Components Operating
WSES-FSAR-UNIT-3 9-x Revision 11-B (06/02)
CHAPTER 9 AUXILIARY SYSTEMS LIST OF FIGURES (Cont'd)
Figure Title 9.3-8 Limited Cooldown One LPSI Pump and One SDHX Operating 9.3-8A Cooldown Without A-C Coolant Temperatures In Loop B (Atmospheric Dump Valve And Main Steam Cross-Connect Unavailable)
(DRN 00-691, R11-A) 9.3-8B Cooldown Without A-C Coolant Temperatures In Loop A (Atmospheric Dump Valve Operable)
(DRN 00-691, R11-A) 9.3-9 Hydrogen Storage System 9.3-10 SDCS Relief Valves 9.3-11 Post Accident Sampling System (DRN 01-1335, R11-B 9.4-1 Flow Diagram - Control Room Air Conditioning System (Sheet 1 of 2) 9.4-1 Flow Diagram - Control Room Air Conditioning System (Sheet 2 of 2)
(DRN 01-1335, R11-B) 9.4-2 Fuel Handling Building Ventilation System 9.4-3 Reactor Auxiliary Building Ventilation Systems (Sheet 1 of 9) 9.4-3 Reactor Auxiliary Building Ventilation Systems (Sheet 2 of 9) 9.4-3 Reactor Auxiliary Building Ventilation Systems (Sheet 3 of 9) 9.4-3 Reactor Auxiliary Building Ventilation Systems (Sheet 4 of 9)
(DRN 01-419) 9.4-3 Reactor Auxiliary Building Ventilation Systems (Sheet 5 of 9)
(DRN 01-419) 9.4-3 Reactor Auxiliary Building Ventilation Systems (Sheet 6 of 9) 9.4-3 Reactor Auxiliary Building Ventilation Systems (Sheet 7 of 9) 9.4-3 Reactor Auxiliary Building Ventilation Systems (Sheet 8 of 9) 9.4-3 Reactor Auxiliary Building Ventilation Systems (Sheet 9 of 9) 9.4-4 RAB Cable Vault and Switchgear Areas Ventilation System 9.4-5 RAB Hot Machine Shop and Decontamination Area Ventilation System (DRN 01-419) 9.4-6 Turbine Building Ventilation Systems (DRN 01-419) 9.4-7 Reactor Building Ventilation Systems
WSES-FSAR-UNIT-3 9-xi Revision 11-B (06/02)
CHAPTER 9 AUXILIARY SYSTEMS LIST OF FIGURES (Cont'd)
Figure Title 9.5-1 Telephone Communication System Diagram (Sheet 1 of 4) 9.5-1 Telephone Communication System Diagram (Sheet 2 of 4)
(DRN 01-419) 9.5-1 Telephone Communication System Diagram (Sheet 3 of 4)
(DRN 01-419) 9.5-1 Telephone Communication System Diagram (Sheet 4 of 4) 9.5-2 Paging Communication System Diagram (Sheet 1 of 2) 9.5-2 Paging Communication System Diagram (Sheet 2 of 2) 9.5-3 Diesel Generator Fuel Oil Storage and Transfer System 9.5-3a Emergency Diesel Miscellaneous Piping 9.5-4 Diesel Engine Jacket Water Cooling System Schematic 9.5-5 Diesel Engine Starting System Schematic 9.5-6 Diesel Generator Lubrication System 9.5-7 Diesel Generator Combustion Air Intakes and Exhausts 9.5-8 Emergency Communication System Diagram - (Magneto/Sound Powered System) 9.5.1-1 Flow Diagram - Fire, Makeup and Domestic Water (Sheet 1 of 3) 9.5.1-1 Flow Diagram - Fire, Makeup and Domestic Water (Sheet 2 of 3) 9.5.1-1 Flow Diagram - Fire, Makeup and Domestic Water (Sheet 3 fo 3)
(DRN 01-419) 9.5.1-2 Fire Protection Cooling Towers - Plan (DRN 01-419) 9.5.1-3 Fire Protection Reactor Auxiliary Building Plan EL -35.00' 9.5.1-4 Fire Protection Reactor Auxiliary Building Plan EL -4.00' 9.5.1-5 Fire Protection Reactor Auxiliary Building Plan EL +21.00' 9.5.1-6 Fire Protection Reactor Auxiliary Building Plan EL +46.00' (DRN 00-691, R11-A) 9.5.1-7 Fire Protection Reactor Auxiliary Building Section Sheet 1 (DRN 00-691, R11-A)
WSES-FSAR-UNIT-3 9-xii Revision 11-B (06/02)
CHAPTER 9 AUXILIARY SYSTEMS LIST OF FIGURES (Cont'd)
Figure Title 9.5.1-8 Fire Protection Reactor Auxiliary Building Sections Sheet 2 9.5.1-9 Fire Protection Reactor Auxiliary Building Sections 3 Sheet 3 (DRN 00-691, R11-A) 9.5.1-10 Fire Protection Reactor Auxiliary Building Sections Sheet 4 (DRN 00-691, R11-A) 9.5.1-11 Fire Protection Fuel Handling Building - Plans 9.5.1-12 Fire Protection Fuel Handling Building - Sections 9.5.1-13 Fire Protection Reactor Building - Plan EL -35.00' EL -4.00' (DRN 01-419) 9.5.1-14 Fire Protection Reactor Building - Plan EL +21.00 (DRN 01-419) 9.5.1-15 Fire Protection Reactor Building - Plan EL +46.00' 9.5.1-16 Fire Protection Turbine Building Ground Floor Plan EL 15.00' 9.5.1-17 Fire Protection Turbine Building Mezz. Floor Plan EL +40.00' 9.5.1-18 Fire Protection Turbine Building Operating Floor Plan EL +67.00' 9.5.1-19 Fire Protection Turbine Building Sections B-B and C-C 9.5.1-20 Fire Protection Turbine Building Section A-A 9.5.1-21 Fire Protection Auxiliary Building Plan EL +35.00'
WSES-FSAR-UNIT-3 9-xiii Revision 13 (04/04)
UPDATE REFERENCE LIST Chapter 9 Section Cross References Revision 12-B Section 9.3.3.2.2.4 ER-W3-2002-0663-001/DRN 03-213 Section 9.2.9.3 ER-W3-2000-0563-000/DRN 02-1623 Table 9.3-13 Sh 4 ER-W3-2003-0132-000/DRN 03-275 Table 9.5.1-1 Sh 1 ER-W3-2002-0469-000/DRN 02-1351 Figure 9.5.1-16 Figure 9.5.1-17 Figure 9.5.1-20 Figure 9.4-3 Sh 8 ER-W3-2001-1065-000/DRN 02-1534 Revision 12-C Section 9.5.1.2.2 ER-W3-2003-0220-000/DRN 03-578 Section 9.5.1.3.1 Section 9.5.4.1 ER-W3-2003-0227-000/DRN 03-635 Section 9.5.4.2 Section 9.5.5.3 Section 9.5.6.2 Section 9.5.6.3 Section 9.5.7.2 Section 9.5.7.3 Table 9.5-1 Sht 1 Table 9.5-1 Sht 3 Table 9.5-2 Sht 1 Table 9.5-2 Sht 2 Table 9.5-3 Table 9.5-4 Sht 1 Table 9.5-4 Sht 2 Table 9.5-5 Sht 2 Revision 13 Figure 9.5-1 Sht 2 ER-W3-2000-0147-001/DRN 02-147 Table 9.2-1 Sht 5 ER-W3-2000-1073-000/DRN 02-1197 Section 9.3.4.3.2 ER-W3-2000-0106-002/DRN 03-760 Section 9.5.1.2.2 ER-W3-2001-1024-009/DRN 03-993 Section 9.5.1.3.2 Section 9.1.4.2.2.6 ER-W3-2002-0430-000/DRN 03-1341
WSES-FSAR-UNIT-3 9-xiv Revision 14 (12/05)
UPDATE REFERENCE LIST Chapter 9 Section Cross References Revision 13 Table 9.3-15 Sht 40 ER-W3-2003-0502-001/DRN 03-2021 Table 9.3-15 Sht 42 Figure 9.4.4 ER-W3-2003-0170-000/DRN 04-249 Revision 13-A Figure 9.3-1 Sht 6 ER-W3-2004-128/DRN 04-992 Figure 9.3-1 Sht 9 Revision 13-B Table 9.1-3 Sht. 5 ER-W3-2004-0205/DRN 04-487 Figure 9.1-5 ER-W3-2004-0377/DRN 04-1069 Table 9.2-12 Sht.2 ER-W3-2003-0489-000/DRN 04-92 Figure 9.3-2 Sht. 1 ER-W3-2001-0377-000/DRN 02-1052 Figure 9.5-1 Sht. 2 ER-W3-2003-0769-002/DRN 04-1393 Figure 9.5-2 Sht. 2 Revision 14 Section 9.1.4.2.2.13 ER-W3-2001-0305-001/DRN 02-176 Section 9.1.4.2.3.3 Table 9.1-5 sh 1 Figure 9.1-5 Figure 9.1-17
WSES-FSAR-UNIT-3 9-xv Revision 14-A (03/06)
UPDATE REFERENCE LIST Chapter 9 Section Cross References Revision 14 Contd Section 9.1.3.3 ER-W3-2001-1149-000/DRN 03-2063 Section 9.2.5.2 Section 9.2.5.3.2 Section 9.3-4.22 Section 9.3.6.1.2 Section 9.3.6.2.1 Section 9.3.6.2.2 Section 9.3.6.3.1 Section 9.3.6.3.3 Section 9.3.6.3.4 Table 9.1-3 sh 6-8 Table 9.2-3 sh 1-2 Table 9.2-9 Table 9.2-10 Table 9.3-11 Table 9.3-17 sh 1-2 Figure 9.3-7 Figure 9.3-8 Figure 9.3-8A Figure 9.3-8B Table 9.3-4 shts 1-3 ER-W3-2001-1149-000/DRN 05-251 Section 9.1.3.1 ER-W3-2001-1149-000/DRN 05-968 Section 9.3.8.3 ER-W3-2004-0276-000/DRN 04-977 Section 9.4.1.1 Figure 9.5-3a ER-W3-2004-0324-000/DRN 04-1816 Section 9.2.5.3.3 ER-W3-2004-0615-000/DRN 05-446 Table 9.2.9 Section 9.2.5.3.3 ER-W3-2004-0615-001/DRN 05-1668 Section 9.3.4.2.1.2 ER-W3-2005-0056-000/DRN 05-332 Table 9.4-10 sh 1 ER-W3-2005-0065-000/DRN 05-365 Figure 9.4-3 ER-W3-2005-0070-000/DRN 05-519 Section 9.4.5.8.1 ER-W3-2005-0145-000/DRN 05-787 Revision 14-A Section 9.1 ER-W3-2005-0396-000/DRN 05-1365 Table 9.1-8 sheet 1 Table 9.2-4 sheet 1 ER-W3-2004-0523-000/DRN 05-1663 Table 9.2-4 sheet 2 Figure 9.3-1 sheet 9 ER-W3-2003-0409-000/DRN 05-1434 Section 9.4.5.6.1 ER-W3-2004-0331-000/DRN 05-1480 Table 9.4-1 sheet 2
WSES-FSAR-UNIT-3 9-xvi Revision 15 (03/07)
UPDATE REFERENCE LIST Chapter 9 Section Cross References Revision 14-B Section 9.2.5.3.2 ER-W3-2005-0465-000/DRN 05-1652 Table 9.2-1 sh 1 Table 9.2-1 sh 2 Table 9.2-1 sh 3 Table 9.2-3 sh 1 Table 9.2-3 sh 2 Table 9.2-9 Table 9.2-10 Figure 9.2-4 Figure 9.2-4A Figure 9.2-5A Section 9.5.2.3 ER-W3-2005-0096-000/DRN 06-233 Figure 9.5-1 sh 2 Figure 9.5-2 sh 2 Figure 9.5-4 ER-W3-2005-0442-000/DRN 06-281 Table 9.2-4 sh 1 ER-W3-2006-0178-000/DRN 06-500 Revision 15 Section 9.4.3.5.2.3 ER-W3-2003-0735-000/DRN 03-1988 Table 9.2-5 Sh. 1 Table 9.2-4 ER-W3-2004-0523-000/DRN 05-1663 Section 9.1.4.2.2.15 ER-W3-2006-0223-000/DRN 06-843 Table 9.1-3 Sh. 1 Table 9.1-3 Sh. 2 Table 9.1-3 Sh. 3 Table 9.1-3 Sh. 4 Table 9.1-3 Sh. 7 Table 9.1-6 Sh. 1 Table 9.1-6 Sh. 2 Section 9.2.9.2.4 Table 9.2-1 Sh. 4 Table 9.3-9 Sh. 6 Table 9.3-4 Sh. 1 Table 9.3-4 Sh. 2 Table 9.3-4 Sh. 3 Table 9.3-9 Sh. 1 Section 9.4.1.2.1 Section 9.4.1.3 Table 9.4-9 Sh. 1 Table 9.4-16 Sh. 1 Table 9.5-4 Sh. 1 Table of Contents ER-W3-2006-0281-000/DRN 06-873 Section 9.5.1.3.2 ER-W3-2006-0284-000/DRN 06-874 Table 9.5.1-3 Sh. 3 Table 9.5.1-2 Sh. 1 Section 9.3.6.5 ER-W3-2006-0282-000/DRN 06-886
WSES-FSAR-UNIT-3 9-xvii Revision 302 (12/08)
UPDATE REFERENCE LIST Chapter 9 Section Cross References Revision 15 (Contd)
Table 9.2-3 Sh. 1 ER-W3-2006-0223-000/DRN 06-898 Table 9.2-3 Sh. 2 Section 9.4.1.3 Section 9.4.5.2.2 Section 9.3.6.2.1 Table 9.3-3 ER-W3-2006-0223-000/DRN 06-901 Section 9.2.4.5 ER-W3-2006-0223-000/DRN 06-910 Section 9.3.4.2.1.4 ER-W3-2004-0094-003/DRN 06-1142 Table 9.3-7 Table 9.5-1 Sh. 1 ER-W3-2006-0397-000/DRN 06-1167 Revision 301 Section 9.5.1.2.3 EC-5000081435 Section 9.5.1.3.1 Section 9.5.1.3.2 Table 9.5.1-3 Sh. 1 Figure 9.5.1-8 Section 9.1.4.2.1.1 EC-5000082257 Section 9.1.4.2.1.2 Section 9.5.6.2 EC-5000082405 Table 9.5-4 Sh. 1 Figure 9.5-5 Section 9.1.1.3 EC-5000082411 Section 9.1.2.3 Section 9.1: References Section 9.3.3.2.2.1 EC-2097 Section 9.4.5.2.3 EC-5000082470 Table 9.4-2 Sh. 4 Revision 302 Section 9.3.6.2.1 EC-935 Section 9.3.6.3.1 Table 9.3-1a Table 9.4-2 Sh. 1 EC-2188 Table 9.4-2 Sh. 3 Table 9.4-10 Sh. 1 Table 9.4-10 Sh. 2 Table 9.4-14 Sh. 1 Table 9.4-14 Sh. 2 Table 9.4-14 Sh. 3 Table 9.4-14 Sh. 4 Table 9.4-14 Sh. 5
WSES-FSAR-UNIT-3 9-xviii Revision 304 (06/10)
UPDATE REFERENCE LIST Chapter 9 Section Cross References Revision 302 (Continued)
Table 9.4-14 Sh. 6 Table 9.4-14 Sh. 7 Section 9.5.1.3.1 EC-4606 Section 9.5.1.1.3 EC-9506 Section 9.5.1.3.2 Revision 303 Section 9.2.4.2 EC-530 Section 9.2.5 Section 9.2.5.3.2 Section 9.2.5.3.3 Table 9.2-9 Section 9.1.2.1 EC-8884 Section 9.1: References Section 9.1.4.2.2.16 EC-11204 Section 9.3.4.2.1.2 EC-14241 Section 9.3.4.2.1.5 Revision 304 Section 9.3.4 EC-13560 Table 9.3-9 Sh. 2 Section 9.5.1.3.2 EC-18551 Section 9.5.1.3.2 EC-18667 Figure 9.5.1-8 Figure 9.5.1-9 Section 9.1.1.1 EC-18742 Section 9.1.1.2 Section 9.1.1.3 Section 9.1.2.1 Section 9.1.2.2 Section 9.1.2.3 Section 9.1.2.4.1 Section 9.1.2.4.2 Section 9.1.2.4.3 Section 9.1: References Table 9.1-2 Table 9.1-8 Sh. 1 Table 9.1-8 Sh. 2 Section 9.5.1.3.2 EC-18843 Section 9.1.2.3 EC-22227
WSES-FSAR-UNIT-3 9-xix Revision 305 (11/11)
UPDATE REFERENCE LIST Chapter 9 Section Cross References Revision 305 Section 9.3.4.1.1 EC-4019 Section 9.3.4.2.1.2 Section 9.3.4.2.1.4 Section 9.3.4.2.2 Table 9.3-13 Sheet 3 of 4 Table 9.3-15 Sheet 46 of 60 Table 9.3-7 Section 9.3.6.2.1 EC-14765 Section 9.3.6.2.2 Section 9.3.6.2.3 Table 9.3-20 Sheet 1 of 2 Section 9.1.3.1 EC-8477 Section 9.1.3.2.1 Section 9.1: References Table 9.1-1 Table 9.2-2 Sheet 1 of 3 Table 9.2-3 Sheet 1 of 2 Table 9.2-3 Sheet 2 of 2 Table 9.2-9 Figure 9.1-21 Figure 9.1-22 Section 9.1.4.1.3 EC-14270 Section 9.1.4.2.2.14 Section 9.1.4.2.3.2 Section 9.1.4.3.1 Table 9.1-7 Figure 9.1-18 Figure 9.1-19 Section 9.5.1.3.2 EC-18305 Section 9.5.3.2 EC-23470 Section 9.5.1.3.2 EC-23997 Section 9.5.1.3.1 EC-25884 Section 9.5.1.3.2 Table 9.2-1 Sheet 4 of 5 EC-26241 Table 9.5-1 Sheet 3 of 3 Table 9.5-4 Sheet 2 of 2 Section 9.1.2.2 EC-28458 EC-30504 Section 9.5.6.2 EC-31660
WSES-FSAR-UNIT-3 9-xx Revision 307 (07/13)
UPDATE REFERENCE LIST Chapter 9 Section Cross References Revision 306 Table of Contents EC-14275 Section 9.1.2 Section 9.1.2.1 Section 9.1.2.2 Section 9.1.4.1.3 Section 9.1.4.2.1 Section 9.1.4.2.2.14 Section 9.1.4.2.3.2 Section 9.1.4.3.1 Section 9.1.5 Section 9.1: References Figure 9.1-3 Sheet 1 Figure 9.1-19 Section 9.5.1.3.2 EC-15965 Section 9.4.3.4.1 EC-17580 Section 9.4.3.4.2 Section 9.4.3.4.2.1 Table 9.4-1 Sheet 1 Figure 9.4-5 Section 9.5.1.3.2 EC-19062 Section 9.2.5.2 EC-32877 Section 9.1.4.1.2 EC-35729 Section 9.1.4.4 Revision 307 Figure 9.3-1 Sheet 6 EC-8435 Section 9.3.4.1.1 EC-8458 Section 9.3.4.1.2 Table 9.3-11 Section 9.3.6.1 Section 9.3.6.1.2 Section 9.3.6.3.2 Section 9.3.6.3.3 Section 9.2.5.3.2 EC-8465 Table 9.2-3 Sheet 1 of 2 Table 9.2-3 Sheet 2 of 2 Table 9.2-9 Table 9.2-10 Table 9.3-4 Sheet 1 of 3 thru Table 9.3-4 Sheet 3 of 3 Figure 9.2-4 Figure 9.2-4A Figure 9.2-5a Figure 9.3-8A Figure 9.3-8B
WSES-FSAR-UNIT-3 9-xxi Revision 309 (06/16)
UPDATE REFERENCE LIST Chapter 9 Section Cross References Revision 307 (Continued)
Section 9.2.2.2.1 EC-30976 Table 9.2-2 Sheet 2 of 3 Section 9.3.6.2.1 Section 9.3.6.2.2 Section 9.3.6.3.1 Section 9.3.6.3.2 Table 9.3-16 Sheet 7 of 11 Section 9.4.5.7.1 EC-33471 Section 9.2.5.3.1 EC-38632 Section 9.3.9.2.1 EC-41095 Section 9.3.1.1 EC-41355 Section 9.3.6.3.3 Section 9.3.9.1 Section 9.3.9.3 Table 9.2-4 Sheet 2 of 2 Section 9.5.2.2.1 EC-43424 Section 9.1.4.1.3 EC-44151 Revision 308 Section 9.2.5.3.3 LBDCR 13-018 Section 9.4.3.3.2 LBDCR 14-011 Section 9.5.1.2.2 EC 35260 Section 9.5.1.6.4 LBDCR 13-015 Section 9.5.1.3.2 LBDCR 14-020 Table 9.5-4 Sh. 1 of 2 EC 43474 Revision 308A Section 9.3 LBDCR 15-028 Revision 309 Section 9.5.6.2 LBDCR 14-017 Table 9.1-4 Sheet 10 of 10 LBDCR 16-013 Table 9.1-4 Sheet 3 of 10 LBDCR 15-007 Figure 9.5.1-9 LBDCR 14-002 Figure 9.5.1-16 Figure 9.5.1-17 Figure 9.5.1-19 Figure 9.5-5