302081, Sheet Na, Rev 058, Feedwater Flow Diagram
ML16130A282
Person / Time
Site: Three Mile Island Constellation icon.png
Issue date: 04/11/2016
From:
Exelon Generation Co
To:
Office of Nuclear Reactor Regulation
Shared Package
ML16127A520 List: ... further results
References
TMI-16-035
Download: ML16130A282 (1)


Text

H IG I I I I I !F I I I 'E I I I I jo I I I I I I c B IA 8 o-o

(.) 0 V> <D 6 di w >o-o g :10" " -U> 0 :::. °' I< LL .,,-1 > I 6 u 5 en :::!: O I< o:::C\I* 7 12" F.W. PUMP BYPASS 1" 1" VENT 20" THIS DWG (C-2 41 THIS DWG (C-2) 6" 1" 2" SEE DWG CE 1" TO YA-V71A 301-181 (A-6 MAIN FEED WATER PUMP 18 FW*P1B 302-182 37 TO VA-V71B {H-3) 301-181 (A-8) NOTES: 1. VALVE POSJTIONS SHOWN FOR REFERENCE ONLY. ACTUAL POSITIONS CONTROLLED BY PROCEDURES.

2. ALL INSTRUMENT TAG NUMBERS ARE PREFIXED BY SYSTEM DESIGNATOR UNLESS OTHERWISE NOTED. 3. SET POINT VALUES FOR RELIEF VALVES TO BE FOUND IN THE APPLICABLE ENGINEERING SET POINT DATA BASE. 4. FOR STEAM GENERATOR AND FEEDWATER INSTRUMENTATION, SEE B&W DWG. 27556F. 5. FOR TI-HS MciDIFICATION LM-13: SEISMIC CLASS S-1 PIPING CLASS S-1 QUALITY CLASS l.T.S. CLEANLINESS CLASS -CLASS B PER GPUSC, SPECIFICATION 30508-001 SYSTEM DESIGN BASIS; SEISMIC CLASS Ill, UNLESS OTHERWISE NOTED. 6. INSTRUMENTS MARKED
  • ARE PREFIXED BY "CO" SYSTEM DESIGNATOR.
7. PT-60, 61 AND Pl-60A, 61A ARE 0 EX" SYSTEM. 8. REDUCER CHANGED TO STAINLESS STEEL PER EER 90-76M. 9. INLET ELBOW CHANGED TO 2 1/4 CHROME-MOLY PER ECR-04-00268.

8 7 FW-V85A 1" FW-VSOA '? 1" DRAIN FW-V12A 6 12* 20" 1/2" FW-V108 5 6" FW-V9A FW-V21A FIJ-V23A FW-V22A t I f W-V24A 1" DtAIN oXAIN STRAIGHTENING VANE FW-Y-3 I 20" STRAIGHTENING VANE FW-Y-2 18 RECIRC. FW-V1B 6" 20* 4 3 2 REVISIONS DESCRIPllON 58 !VARIES I REVISED TO INCORPORATE ECR-12-00110 REV. 5 r --4\7 l 1A RECIRC. FW-V10A H 1/2"1 11/2" FW-V67A FW-V6BA '? '? G 6" 1DVENT FW-V25 FW-V26 FW-V57B 4--f:i'.1---11---0-l..4 o FW-V97A '? 6" 20* FW-1/228 '? 1 DRAIN 1" VENT FW-V42 FW-V41 1" 20" FW-V92A)ff'M 6 ,, FW-V16A -1 1* FW-V53A FW-V54A '? 1" DRAIN 6 FW-V23B FW-V248 '? 1" DRAIN FW-V114A VENT ..... 3/4" FW-V113A H.P. HEATER ----4THSTAGEA FW..J2A VENT ..... 0'-... H.P. HEATER 2NOSTAGEA FW..J1A FW-V62 FW-V100A @

  • I lb I....
  • 10 302-182 (G-8 3" FROM MAIN & AUX. CONDENSER SAMPLE PUMPS c 3ROSTAGE (HOT) HIGH PRESSURE B 2NOSTAGE @ © © @ f7' r.'I "' ID tol t 8 '? r... r.-. 6" CO-V1068 6" CO-V106A CO-V167A 1" '? A 1STSTAGE (COLD) LOW PRESSURE HOTWELL F E I D 4J7--CLEAN UP RECYCLE SEE DWG. 302-181 {H-7) SEE DWG 302-182 20" SEE DWG. 302-181 {H-7) 2 y c.s. FW-V43 CR. MOLY FW-V44 c.s.

R. B. R. B.

1" VENT FW-V56A FW-V55A 1" l" FW-V58A STEAM GENERATOR A RC*H1A MAIN F.W.HEADER 14" STEAM GENERATOR B RC-H1B FW-V578 FW-VSBB 1" VENT FW-V568 /W-V55B 11" 20* 1" l!" FW-V538 FW-V54B '? '? '? 1" DRAIN 1" DRAINS R.B. R.B. 5 4 1" VENT FW-V46 6" LOW LOAD t--CONTROL T VALVE Ul F.A.I. _ J, 3 302-003 302-002 302-001 DWG. NO. TEMP. HOT FUNCTIONAL TEST CONN. 1/2" 6" 1" V1688 2" I

__lcE\ (H-3 4) 6"11 6 co-V168A 2* c ©I Y J. '? 1/4" FW-V128 1" VENT 1., FW-V51 FW-V52 COh.IPOi'IENT

&: SYS ID INOEX S'r'MBOLS INS1RUMENTA110N SYMBOLS FLOW DIAGRAM TI1\.E REFERENCES 1" 2 U> z1 9 1 R58 Exelon. 00 L---=::::-1-::---;-----------, /'I I THIS IS A COMPUTER GENERATED DRAWING DO NOT REVISE IT MANUALLY Nuclear FEEDWATER FLOW DIAGRAM TMl-1 I 302..()81 I 58 I NONE IBA NO. A H IG I I I I I !F I I I 'E I I I I jo I I I I I I c B IA 8 o-o

(.) 0 V> <D 6 di w >o-o g :10" " -U> 0 :::. °' I< LL .,,-1 > I 6 u 5 en :::!: O I< o:::C\I* 7 12" F.W. PUMP BYPASS 1" 1" VENT 20" THIS DWG (C-2 41 THIS DWG (C-2) 6" 1" 2" SEE DWG CE 1" TO YA-V71A 301-181 (A-6 MAIN FEED WATER PUMP 18 FW*P1B 302-182 37 TO VA-V71B {H-3) 301-181 (A-8) NOTES: 1. VALVE POSJTIONS SHOWN FOR REFERENCE ONLY. ACTUAL POSITIONS CONTROLLED BY PROCEDURES.

2. ALL INSTRUMENT TAG NUMBERS ARE PREFIXED BY SYSTEM DESIGNATOR UNLESS OTHERWISE NOTED. 3. SET POINT VALUES FOR RELIEF VALVES TO BE FOUND IN THE APPLICABLE ENGINEERING SET POINT DATA BASE. 4. FOR STEAM GENERATOR AND FEEDWATER INSTRUMENTATION, SEE B&W DWG. 27556F. 5. FOR TI-HS MciDIFICATION LM-13: SEISMIC CLASS S-1 PIPING CLASS S-1 QUALITY CLASS l.T.S. CLEANLINESS CLASS -CLASS B PER GPUSC, SPECIFICATION 30508-001 SYSTEM DESIGN BASIS; SEISMIC CLASS Ill, UNLESS OTHERWISE NOTED. 6. INSTRUMENTS MARKED
  • ARE PREFIXED BY "CO" SYSTEM DESIGNATOR.
7. PT-60, 61 AND Pl-60A, 61A ARE 0 EX" SYSTEM. 8. REDUCER CHANGED TO STAINLESS STEEL PER EER 90-76M. 9. INLET ELBOW CHANGED TO 2 1/4 CHROME-MOLY PER ECR-04-00268.

8 7 FW-V85A 1" FW-VSOA '? 1" DRAIN FW-V12A 6 12* 20" 1/2" FW-V108 5 6" FW-V9A FW-V21A FIJ-V23A FW-V22A t I f W-V24A 1" DtAIN oXAIN STRAIGHTENING VANE FW-Y-3 I 20" STRAIGHTENING VANE FW-Y-2 18 RECIRC. FW-V1B 6" 20* 4 3 2 REVISIONS DESCRIPllON 58 !VARIES I REVISED TO INCORPORATE ECR-12-00110 REV. 5 r --4\7 l 1A RECIRC. FW-V10A H 1/2"1 11/2" FW-V67A FW-V6BA '? '? G 6" 1DVENT FW-V25 FW-V26 FW-V57B 4--f:i'.1---11---0-l..4 o FW-V97A '? 6" 20* FW-1/228 '? 1 DRAIN 1" VENT FW-V42 FW-V41 1" 20" FW-V92A)ff'M 6 ,, FW-V16A -1 1* FW-V53A FW-V54A '? 1" DRAIN 6 FW-V23B FW-V248 '? 1" DRAIN FW-V114A VENT ..... 3/4" FW-V113A H.P. HEATER ----4THSTAGEA FW..J2A VENT ..... 0'-... H.P. HEATER 2NOSTAGEA FW..J1A FW-V62 FW-V100A @

  • I lb I....
  • 10 302-182 (G-8 3" FROM MAIN & AUX. CONDENSER SAMPLE PUMPS c 3ROSTAGE (HOT) HIGH PRESSURE B 2NOSTAGE @ © © @ f7' r.'I "' ID tol t 8 '? r... r.-. 6" CO-V1068 6" CO-V106A CO-V167A 1" '? A 1STSTAGE (COLD) LOW PRESSURE HOTWELL F E I D 4J7--CLEAN UP RECYCLE SEE DWG. 302-181 {H-7) SEE DWG 302-182 20" SEE DWG. 302-181 {H-7) 2 y c.s. FW-V43 CR. MOLY FW-V44 c.s.

R. B. R. B.

1" VENT FW-V56A FW-V55A 1" l" FW-V58A STEAM GENERATOR A RC*H1A MAIN F.W.HEADER 14" STEAM GENERATOR B RC-H1B FW-V578 FW-VSBB 1" VENT FW-V568 /W-V55B 11" 20* 1" l!" FW-V538 FW-V54B '? '? '? 1" DRAIN 1" DRAINS R.B. R.B. 5 4 1" VENT FW-V46 6" LOW LOAD t--CONTROL T VALVE Ul F.A.I. _ J, 3 302-003 302-002 302-001 DWG. NO. TEMP. HOT FUNCTIONAL TEST CONN. 1/2" 6" 1" V1688 2" I

__lcE\ (H-3 4) 6"11 6 co-V168A 2* c ©I Y J. '? 1/4" FW-V128 1" VENT 1., FW-V51 FW-V52 COh.IPOi'IENT

&: SYS ID INOEX S'r'MBOLS INS1RUMENTA110N SYMBOLS FLOW DIAGRAM TI1\.E REFERENCES 1" 2 U> z1 9 1 R58 Exelon. 00 L---=::::-1-::---;-----------, /'I I THIS IS A COMPUTER GENERATED DRAWING DO NOT REVISE IT MANUALLY Nuclear FEEDWATER FLOW DIAGRAM TMl-1 I 302..()81 I 58 I NONE IBA NO. A