ML14129A451
| ML14129A451 | |
| Person / Time | |
|---|---|
| Site: | Aerotest |
| Issue date: | 05/09/2014 |
| From: | NRC/OGC |
| To: | Atomic Safety and Licensing Board Panel |
| SECY RAS | |
| References | |
| 50-228-LT, ASLBP 14-931-01-LT-BD01, RAS 25924 | |
| Download: ML14129A451 (15) | |
Text
Attachment 1 Aerotest Operations, Inc. License Transfer Hearing File and Mandatory Disclosures Hearing File Index Initial Disclosures - May 9, 2014 The hearing file index lists each item in the hearing file that is not otherwise privileged or protected, which includes those materials required by 10 C.F.R. § 2.1303, as well as the Staffs mandatory disclosures produced pursuant to 10 C.F.R. § 2.336(b) and (c). These items may be accessed through the Agencywide Documents Access and Management System (ADAMS).
ADAMS Document ID # Accession Document Title/Description Date Number 00-0001 ML003708596 04/14/2000 Letter discussing progress of Agreement between OEA and Autoliv Inc,a Delaware Corporation headquartered in Stockholm,Sweden.
00-0002 ML003704794 04/14/2000 Letter informing NRC that Aerotest Operations, Inc is holder of facility license and operates Aerotest Radiography and Research Reactor.
00-0003 ML003756928 10/18/2000 Transfer of Ownership 00-0004 ML003755637 10/07/2003 Divestiture Plan Regarding Indirect Transfer of the Aerotest Radiography and Research Reactor (ARRR) to Autoliv ASP, Inc., and Autoliv, Inc. (TAC NO. MB1977).
Page 1 of 15
ADAMS Document ID # Accession Document Title/Description Date Number 00-0005 ML003756103 12/04/2003 AUTOLIV letter on Divestiture Plan Regarding Indirect Transfer of the Aerotest Radiography and Research Reactor to Autoliv ASP, Inc., and Autoliv, Inc.
00-0006 ML040430500 12/22/2003 Extension of Response Time for Divestiture Plan Regarding Indirect Transfer of the Aerotest Radiography and Research Reactor (ARRR) to Autoliv ASP, Inc., and Autoliv, Inc. (TAC NO.
MB1977).
00-0007 ML010040210 01/29/2004 Divestiture Plan regarding Indirect Transfer of Aerotest Radiography & Research Reactor (ARRR).
00-0008 ML011140283 02/20/2004 Divestiture Plan Regarding the Aerotest Radiography and Research Reactor (TAC No. MB1977).
00-0009 ML040570076 03/31/2004 Divestiture Plan Regarding Indirect Transfer of the Aerotest Radiography and Research Reactor (ARRR).
00-0010 ML012210060 06/04/2004 Letter on Divestiture Plan Regarding Indirect Transfer of the Aerotest Radiography and Research Reactor.
00-0011 ML011980287 07/29/2004 Divestiture Plan Regarding Indirect Transfer of the Aerotest Radiography and Research Reactor Docket No. 50-228, License no. R-98 (TAC No. MB13977).
00-0012 ML012270209 10/12/2004 Divestiture Plan Regarding Indirect Transfer of the Aerotest Radiography and Research Reactor (ARRR).
Page 2 of 15
ADAMS Document ID # Accession Document Title/Description Date Number 00-0013 ML012500147 12/22/2004 Divestiture Plan Regarding Indirect Transfer of the Aerotest Radiography and Research Reactor (ARRR).
00-0014 ML012910081 03/03/2005 Divestiture Plan Regardig Indirect Transfer of the Aerotest Radiography and Research Reactor (ARRR).
00-0015 ML023260271 04/26/2005 Divestiture Plan Regarding Indirect Transfer of the Aerotest Radiography and Research Reactor (ARRR).
00-0016 ML023370316 07/21/2005 Autoliv Letter on Divestiture plan regarding indirect transfer of the Aerotest Radiography and Research Reactor.
00-0017 ML031750887 10/05/2005 Autoliv Letter on Divestiture Plan Regarding Indirect Transfer of Aerotest Radiography and Research Reactor.
00-0018 ML032550142 12/05/2005 Divestiture Plan Regarding Indirect Transfer of the Aerotest Radiography and Research Reactor (ARRR).
Page 3 of 15
ADAMS Document ID # Accession Document Title/Description Date Number 00-0019 ML040430495 02/01/2006 Divestiture Plan re Indirect Transfer of the Aerotest Radiography Research Reactor.
00-0020 ML033440246 04/12/2006 Divestiture Plan Regarding Indirect Transfer of Aerotest Radiography and Research Reactor (ARR).
00-0021 ML033510384 01/24/2007 Autoliv Letter on Divesture Plan re Indirect Transfer of Aerotest Research Radiography and Research Reactor.
00-0022 ML040340559 07/09/2009 Aerotest Operations, Inc., Proposed Denial of Renewal of Facility Operating License No. R-98.
00-0023 ML040350790 07/21/2009 G20090422/LTR-09-0372/EDATS: SECY-2009-0363 - Ltr. Jay E. Silberg Re: Aerotest Radiography and Research Reactor, Request for Extension to Demand Hearing.
00-0024 ML041000498 07/24/2009 G20090422/LTR-09-0372/EDATS: SECY-2009-0363 - Aerotest Operations, Inc. - NRC Response to Request for Extension of Time to Request Hearing on Proposed Denial of License Renewal For Facility License No. R-98 (Tac MD8177).
00-0025 ML041680175 09/04/2009 LTR-09-0452 - Robert Haemer Ltr. re: Aerotest Radiography and Research Reactor Docket No. 50-228 - Request for Extension to Consider the Proposed Denial of a Renewal Request.
Page 4 of 15
ADAMS Document ID # Accession Document Title/Description Date Number 00-0026 ML042170244 09/11/2009 Aerotest: NRC Response to Request For Second Extension Of Time To Request, Hearing On Proposed Denial Of License Renewal For Facility Operating License R-98.
00-0027 ML042380162 11/17/2009 Aerotest Operations, Inc., NRC Response To November 2, 2009 Extension Of Time To Request Hearing On Proposed Denial Of License Renewal (Tac ME1887).
00-0028 ML042890301 11/23/2009 Aerotest Operations, Inc., November 18, 2009 Status of Divestiture.
00-0029 ML043580215 01/07/2010 2010/01/07- Letter from Robert B. Haemer, Counsel for Aerotest Operations, Inc. to the Secretary of the Commission requesting an extension to consider the proposed denial of a renewal request.
00-0030 ML13120A327 02/02/2010 Aerotest Operations, Inc. - U. S. Nuclear Regulatory Commission Response To Request For Extension Of Time To Request Hearing On Proposed Denial Of License Renewal For Facility Operating License No. R-98 (TAC ME1887).
00-0031 ML050660109 08/06/2010 08/06/2010 Letter from Sandra Warren, General Manager of Aerotest Operations, Inc.
00-0032 ML050760217 09/03/2010 Request for Extension to Transfer Order.
Page 5 of 15
ADAMS Document ID # Accession Document Title/Description Date Number 00-0033 ML051190028 09/13/2010 Aerotest Operations, Inc. - Letter to Licensee Re: Order Extending The Effectiveness Of The Approval Of The Indirect Transfer Of Facility Operating License For Aerotest Operations, Inc.,
Aerotest Radiography And Research Reactor.
00-0034 ML051380438 09/20/2010 Aerotest Operations, Inc., Report of Progress Made Toward Completion of the License Transfer.
00-0035 ML052150188 09/27/2010 Description of Anticipated Agreements with the U.S. Department of Energy and the U.S. Department of Defense.
00-0036 ML052790058 09/27/2010 Report of Progress Made Toward Completion of the License Transfer.
00-0037 ML053480143 10/04/2010 NRC-2010-0178; Report of Progress Made Toward Completion of the License Transfer.
00-0038 ML060370209 10/13/2010 Aerotest Operations, Inc., Report of Progress Made Toward Completion of License Transfer.
00-0039 ML061070299 10/15/2010 Aerotest Operations Inc. - E-mail Regarding Cease of Operations.
Page 6 of 15
ADAMS Document ID # Accession Document Title/Description Date Number 00-0040 ML070250313 01/07/2011 Aerotest Radiography and Research Reactor Requesting Withdrawal of Letters Dated December 10, 2010 and January 4, 2011, and Further Requests Correspondence be Replaced by This Letter.
00-0041 ML071700653 02/04/2011 Aerotest Radiography and Research Reactor License No. R-98.
00-0042 ML103370137 02/21/2011 Aerotest Operations, Inc., Report of Status of Efforts to Divest Itself of the Aerotest Radiography and Research Reactor (ARRR).
00-0043 ML090300068 03/07/2011 Aerotest Operations, Inc. - Report of the Status of Efforts to Divest itself of the Aerotest Radiography and Research Reactor.
00-0044 ML120900629 03/21/2011 Aerotest Operations, Inc. - Report on Status of Efforts to Divest Itself of the Aerotest Radiography and Research Reactor ("ARRR").
00-0045 ML090710206 06/14/2011 Aerotest Radiography and Research Reactor, Response to NRC Letter of May 24, 2011 re Confirmatory Action Letter.
00-0046 ML091030408 09/14/2011 IR 05000228-11-201, on August 15-17, 2011 at Aerotest Operations, Inc. - NRC Routine Inspection Report No. 50-228/2011-201.
Page 7 of 15
ADAMS Document ID # Accession Document Title/Description Date Number 00-0047 ML091140059 11/29/2011 Aerotest Radiography and Research Reactor, Thirteenth Response to NRC Letters of February 26, 2011 and May 24, 2011.
00-0048 ML091200720 12/12/2011 Aerotest Operations, Inc., Note to File Re: Teleconference on December 9, 2011 Re: Confirmatory Action Letter No. NRR-2011-001 Progress Report.
00-0049 ML091320231 12/12/2011 Aerotest Radiography and Research Reactor - Confirmation of Changes in Decommissioning Plan Submittal Date.
00-0050 ML091280657 12/13/2011 Aerotest Radiography and Research Reactor - Fourteenth Response to NRC Letters of February 26, 2011 and May 24, 2011.
00-0051 ML091660062 12/27/2011 1/18/2012, Forthcoming Category 1 Public Meeting with Aerotest Operations, Inc., to Discuss the Status of Items in the Confirmatory Action Letter No. NRR-2011-001.
00-0052 ML091770065 12/27/2011 Aerotest Operations Inc. - NRC Response to Aerotest RE: Confirmatory Action Letter No. NRR-2011-001.
00-0053 ML090830578 01/11/2012 Aerotest Operations, Inc., Discovery of Four Aluminum TRIGS Elements what was Assumed were Non-Displaced Cracks in the Annual Fuel Inspection from December 5-12, 2011 Report.
00-0054 ML092080163 01/20/2012 01/18/2012 Summary of Public Meeting with Aerotest Operations, Inc., to Discuss the Status of Items in the Confirmatory Action Letter No. NRR-2011-001.
Page 8 of 15
ADAMS Document ID # Accession Document Title/Description Date Number 00-0055 ML092170638 01/20/2012 Aerotest Operations, Inc., Follow-Up Report to 01/11/2011 Report Regarding Cracks in the Elements.
00-0056 ML092040371 01/24/2012 Aerotest Radiography and Research Reactor - Seventeenth Response to NRC Letters of February 26, 2011 and May 24, 2011.
00-0057 ML092090043 02/07/2012 IR 05000228-12-201, on January 17 & 18, 2012 at Aerotest Operations, Inc., Research Reactor -
NRC Non-Routine Inspection Report No. 50-228/2012-201 00-0058 ML092110543 03/12/2012 03/09/2012 - Teleconference Between Aerotest and the NRC RE: Status Since 1/24/2012 Letter Regarding Negotiations.
00-0059 ML092290360 03/20/2012 Twenty-first Response to NRC Letters of February 26, 2011 and May 24, 2011.
00-0060 ML092260128 03/30/2012 Pillsbury, Winthrop, Shaw, Pittman, LLP, Letter Regarding the Sale of Aerotest Radiography and Research Reactor, Docket 50-228.
00-0061 ML092600267 03/31/2012 Aerotest Operations Inc. - Note to File - Minutes from the March 30, 2012 Conference Call between Aerotest and the NRC.
Page 9 of 15
ADAMS Document ID # Accession Document Title/Description Date Number 00-0062 ML092510049 04/04/2012 Letter regarding Nuclear Labyrinth acquiring the Ownership of the Stock and Business of Aerotest Operations.
00-0063 ML092260564 04/24/2012 Aerotest Operations, Inc. - Schedule for Submission of License Transfer Application - Operating License No. R-98.
00-0064 ML092780616 05/30/2012 Application for Consent to Indirect Transfer of Control of Licenses.
00-0065 ML092800054 05/30/2012 Transmittal of Application for Approval of Indirect Transfer of Control of License Pursuant to 10 C.F.R 50.80.
00-0066 ML093290292 07/05/2012 Aerotest Operations, Inc. and Nuclear Labyrinth LLC Request for Supplemental Information(TAC NO.
ME8811).
00-0067 ML093090309 07/05/2012 Aerotest Operations, Inc. and Nuclear Labyrinth LLC Request to Supplement the License Transfer Application (TAC NO. ME8811).
00-0068 ML100140375 07/15/2012 Note to File - Summary of the Informal Conference Call of June 21, 2012, Between Aerotest Operations, Inc./Nuclear Labyrinth, and the NRC.
Page 10 of 15
ADAMS Document ID # Accession Document Title/Description Date Number 00-0069 ML100141716 07/19/2012 Response to Request to Aerotest Operations, Inc. and Nuclear Labyrinth, LLC to Supplement the License Transfer Application.
00-0070 ML100270293 07/31/2012 Annual Summary of Changes, Tests and Experiments at Aerotest Radiography and Research Reactor (ARRR), for the Period of 1 July 2011 to 30 June 2012.
00-0071 ML100490068 08/10/2012 Aerotest Operations, Inc., Reporting that During Follow-up Fuel Inspection from July 16, 2012 - July 25, 2012, an Additional 17 Elements of Non-Displaced Cracks were Discovered.
00-0072 ML100120418 08/14/2012 Aerotest Operations, Inc., Acceptance of Requested Indirect License Transfer Application (TAC No.
ME8811).
00-0073 ML100880295 08/14/2012 IR 05000228/12-204 on July 16-23, 2012 at Aerotest Operations Inc., - NRC Non-Routine Inspection Report No. 50-228/2012-204.
00-0074 ML100500404 09/14/2012 Aerotest Operations Inc., and Nuclear Labyrinth LLC - Enclosure 2 NON-PROP Request for Additional Information Re: Application for Approval of Indirect Transfer of Control of License of Aerotest Radiography and Research Reactor (TAC ME8811).
00-0075 ML100760616 09/14/2012 Aerotest Operations, Inc., and Nuclear Labyrinth LLC - Transmittal Letter for Proprietary and Non-Prop Request for Additional Information Re: Application for Approval of Indirect Transfer of Control of License of ARRR Pursuant to 10 CFR 50.80 (TAC ME8811 00-0076 ML100760618 09/26/2012 IR 05000228/12-205 on September 10-12, 2012 at Aerotest Operations, Inc. - NRC NON-ROUTINE Inspection Report No. 50-228/2012-205.
Page 11 of 15
ADAMS Document ID # Accession Document Title/Description Date Number 00-0077 ML100770354 10/15/2012 Response to Request for Additional Information re: Application for Approval of Indirect Transfer of Control of License of Aerotest Radiography and Research Reactor Pursuant to 10 CFR 50.80 (TAC No. ME8811).
00-0078 ML100880338 11/20/2012 Aerotest Operations, Inc. - Letter to the Licensee Re: Notice of Consideration of Approval of Indirect Transfer and Conforming Amendment, Opportunity for a Hearing, and Order.
00-0079 ML100980153 11/30/2012 Aerotest Operations Inc.- Federal Register Notice of Consideration of Indirect License Transfer and Conforming Amendment, Opportunity for Hearing, and Order Imposing Procedures for Access to SUNSI.
00-0080 ML101120070 12/04/2012 12/19/2012 Forthcoming Public Meeting with Aerotest Operations, Inc., and Nuclear Labyrinth LLC Re: Discuss NRC Request for Additional Information Re: Indirect License Transfer.
00-0081 ML100610407 12/10/2012 Aerotest Operations Inc., & Nuclear Labyrinth LLC - Transmittal Letter for PROP & NON-PROP RAI Re: Application for Approval of Indirect Transfer of Control of License of Aerotest Radiography and Research Reactor Pursuant to 10 CFR 50.80 (TAC ME8811).
00-0082 ML100610411 12/10/2012 Aerotest Operations Inc., and Nuclear Labyrinth LLC - Non-Proprietary Request for Additional Information Re: Indirect License Transfer Application (Tac No. ME8811).
00-0083 ML101380228 01/07/2013 Comment (1) of Mark Sokolow on Notice of Consideration of Indirect Transfer and Conforming Amendment.
Page 12 of 15
ADAMS Document ID # Accession Document Title/Description Date Number 00-0084 ML101380287 01/07/2013 IR 05000228/12-206 on December 10-13, 2012 at Aerotest Operations, Inc. - NRC Non-Routine Inspection Report No. 50-228-2012-206.
00-0085 ML101380218 01/10/2013 Response to Request for Additional Information re: Application for Approval of Indirect Transfer of Control of License of Aerotest Radiography and Research Reactor Pursuant to 10 CFR 50.80.
00-0086 ML101380294 01/18/2013 12/19/2012 - Public Meeting Summary with Aerotest Operations, Inc., and Nuclear Labyrinth, LLC Re: NRC Request for Additional Information on License Transfer Application.
00-0087 ML101200562 04/22/2013 Aerotest Operations, Inc.,Comment Submitted to The NRC on The Federal Register Notice; Aerotest Operations, Inc., Consideration Of Indirect Transfer And Conforming Amendment (Docket No. 50-228; NRC-2012-0286).
00-0088 ML101200366 04/25/2013 Comment (2) of Jay E. Silberg for Aerotest Operations, Inc. and Nuclear Labyrinth, LLC Regarding Notice of Consideration of Indirect Transfer and Conforming Amendment.
00-0089 ML102360012 06/18/2013 Aerotest Operations, Inc. - Response to Comment Re: Federal Register Notice of Consideration of Indirect Transfer and Conforming Amendment (Tac No. ME8811).
00-0090 ML103160131 07/15/2013 Aerotest Operations, Inc., Denial of License Transfer Regarding the Aerotest Radiography and Research Reactor, Facility Operating License No. R-098 (TAC ME8811).
Page 13 of 15
ADAMS Document ID # Accession Document Title/Description Date Number 00-0091 ML102510500 07/16/2013 EN-13-024, Issuance of Enforcement Order to Aerotest Operations, Inc. (EA-13-097).
00-0092 ML102460245 07/24/2013 Aerotest Operations, Inc. - FRN version of the Order Denying License Renewal Application And Prohibiting Operation of Aerotest Radiography And Research Reactor, Facility Operating License No.
R-98.
00-0093 ML102450760 07/24/2013 Aerotest Operations, Inc. and Nuclear Labyrinth, LLC - Non-Proprietary Safety Evaluation Re:
Indirect License Transfer (Tac No. ME8811).
00-0094 ML102510084 07/24/2013 Aerotest Operations, Inc., Denial of License Renewal, Denial of License Transfer, and Issuance of Order to Modify License No. R-098 to Prohibit Operation of Aerotest Radiography & Research Reactor, (TAC ME8811 & MC9596).
00-0095 ML102650174 07/30/2013 Annual Summary of Changes, Tests and Experiments at Aerotest Radiography and Research Reactor (ARRR), for Period of 1 July 2012 to 30 June 2013.
00-0096 ML102720403 08/02/2013 Clarification of Deadline for Requesting Hearing on the Denial of License Transfer of Aerotest Radiography and Research Reactor, Facility Operating License No. R-98.
00-0097 ML102720404 08/15/2013 Aerotest Operations, Inc., Ltr Reporting that during Annual Fuel Inspection from July 24-26, 2013, Two More Aluminum Fuel Elements with Non-displaced Cracks, S/N 612E and 630E Discovered.
Page 14 of 15
ADAMS Document ID # Accession Document Title/Description Date Number 00-0098 ML102810415 10/04/2013 Aerotest Operations, Inc. - Requesting Response To An Unresolved Item Identified in NRC Inspection Report No. 50-228/2012-201.
00-0099 ML103140293 11/01/2013 Response to Apparent Violation in NRC Inspection Report No. 50-228/2012-201; EA-13-108.
00-0100 ML102880066 12/18/2013 IR 05000228-12-201 and Notice of Violation, January 17 and 18, 2012, Aerotest Operations, Inc.
Page 15 of 15