ROP-14 2013 Seabrook Station Unit 1 Annual Assessment Letter, Report 05000443/2013001, and Inspection Plan
ML14062A021
Person / Time
Site: Seabrook 
(NPF-086)
Issue date: 03/04/2014
From: Michael Scott
Division Reactor Projects I
To: Walsh K
NextEra Energy Seabrook
DENTEL, GT
References
IR-13-001 IR-13-001
Download: ML14062A021 (5)


Text

March 4, 2014

SUBJECT:

ANNUAL ASSESSMENT LETTER FOR SEABROOK STATION, UNIT NO. 1 (REPORT 05000443/2013001)

Dear Mr. Walsh:

On February 12, 2014, the U.S. Nuclear Regulatory Commission (NRC) completed its end-of-cycle performance review of Seabrook Station, Unit No. 1 (Seabrook). The NRC reviewed the most recent quarterly performance indicators in addition to inspection results and enforcement actions from January 1, 2013 through December 31, 2013. This letter informs you of the NRCs assessment of your facility during this period and its plans for future inspections at your facility.

The NRC determined that overall, Seabrook operated in a manner that preserved public health and safety and met all cornerstone objectives. The NRC determined the performance at Seabrook during the most recent quarter was within the Licensee Response Column of the NRC's Reactor Oversight Process (ROP) Action Matrix because all inspection findings had very low (i.e., green) safety significance, and all Pls indicated that your performance was within the nominal, expected range (i.e., green). On January 24, 2013, the NRC completed a supplemental inspection for a White finding that involved the failure of Seabrook Station personnel to adequately critique the performance of an evaluated emergency preparedness exercise. The NRC determined that Seabrook appropriately addressed the root and contributing causes, extent of condition and corrective actions. The White finding was removed from the assessment process at the end of the first quarter of 2013, resulting in Seabrook transitioning from the Regulatory Response Column to the Licensee Response Column of the NRC's Action Matrix. Therefore, the NRC plans to conduct ROP baseline inspections at your facility.

By letter dated October 9, 2013 (ADAMS Accession No. ML13274A670)1, the NRC closed the Confirmatory Action Letter (CAL) 1-2012-002 issued to you on May 16, 2012 (ADAMS Accession No. ML12125A1721)1 regarding actions taken and planned by NextEra to address the Alkali Silica Reaction (ASR) impacting safety-related reinforced concrete structures at Seabrook. Although NRC review of the CAL is complete, we will maintain a focused oversight

1The NRCs Agencywide Document Access and Management System (ADAMS) accession number for the referenced document. The document is publicly available and retrievable through the ADAMS hyperlink provided at the end of this letter using this number. of NextEras actions to address this non-conforming condition through scheduled six-month inspection activities at Seabrook Station and the Ferguson Structural Engineering Laboratory at the University of Texas at Austin using Inspection Procedure 71152, Problem Identification and Resolution Inspection, annual sampling guidance. These inspection activities have been included in the attachment (Report 22) to this letter.

The enclosed inspection plan lists the inspections scheduled through June 30, 2015. Routine inspections performed by the resident inspectors are not included in the inspection plan. The inspections listed during the last nine months of the inspection plan are tentative and may be revised at the mid-cycle performance review. In addition to baseline inspections, the NRC will perform Temporary Instruction (TI) 182, Review of the Implementation of the Industry Initiative to Control Degradation of Underground Piping and Tanks, and Inspection Procedure (IP) 60855.1, Operation of an Independent Spent Fuel Storage Installation at Operating Plants.

The NRC provides the inspection plan to allow for the resolution of any scheduling conflicts and personnel availability issues. The NRC will contact you as soon as possible to discuss changes to the inspection plan should circumstances warrant any changes. This inspection plan does not include security related inspections, which will be sent via separate, non-publicly available correspondence.

As a result of the Safety Culture Common Language Initiative, the terminology and coding of cross-cutting aspects were revised. All cross-cutting aspects identified during inspections conducted in calendar year (CY) 2014 will reflect this revision to Inspection Manual Chapter (IMC) 0310. The CY 2013 end-of-cycle assessments were conducted using the IMC 0310 guidance in effect in CY 2013 (dated October 28, 2011). Cross-cutting aspects identified in 2013 using the 2013 terminology will be converted to the latest revision in accordance with the cross-reference in IMC 0310 during the mid-cycle assessment review and evaluated for cross-cutting themes and potential substantive cross-cutting issues in accordance with IMC 0305.

In accordance with Title 10 of the Code of Federal Regulations (10 CFR), Part 2.390 of the NRCs Rules of Practice, a copy of this letter will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records component of the NRC's Agencywide Document Access and Management System (ADAMS).

ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room).

Please contact Glenn Dentel at 610-337-5233 with any questions you have regarding this letter.

Sincerely,

/RA Eric J. Benner Acting for/

Michael L. Scott, Acting Director Division of Reactor Projects

Docket No.: 50-443 License No.: NPF-86

Enclosure: Inspection Plan

cc w/encl: Distribution via ListServ

ML14062A021 SUNSI Review

Non-Sensitive Sensitive

Publicly Available Non-Publicly Available

OFFICE RI/DRP RI/DRP RI/DRP

NAME mmt MDraxton/GTD for via email GDentel/ GTD MScott/ EJB for

DATE 02/26/14 02/28/14 02/28/14 Distribution w/encl:

W. Dean, RA D. Lew, DRA M. Scott, DRP E. Benner, DRP R. Lorson, DRS J. Trapp, DRS J. Clifford, DNMS J. Marshall, DNMS Actg G. Dentel, DRP R. Barkley, DRP M. Draxton, DRP B. Reyes, DRP P. Catalso, DRP C. Newport, DRP A. Cass, DRP D. Screnci, PAO N. Sheehan, PAO D. Schroeder, DRP A. Burritt, DRP G. Dentel, DRP F. Bower, DRP R. McKinley, DRP K. Mangan, DRP R. Powell, DRP A. Dimitriadis, DRS J. Noggle, DRS M. Gray, DRS P. Krohn, DRS J. Rogge, DRS D. Jackson, DRS E. Quinones, RI OEDO C. ODaniell, ORA L. Pinkham, DRP K. Heater, DRS T. Haverkamp, DNMS RidsNrrPMSeabrook Resource RidsNrrDorlLpl1-2 Resource ROPReports Resource RidsNrrDirslpab Resource ROPAssessmentResource

Page 1 of 2 02/27/2014 13:55:57 Report 22 Unit Number Planned Dates Start End Inspection Activity Title No. of Staff on Site Seabrook Inspection / Activity Plan 01/01/2014 - 06/30/2015 71124

- RAD HAZARD & ALARA

1 IP Radiological Hazard Assessment and Exposure Controls 71124.01 03/03/2014 03/07/2014

IP Occupational ALARA Planning and Controls 71124.02 03/03/2014 03/07/2014 ASR

- PI&R SAMPLE - ASR MONITORING

1 IP Problem Identification and Resolution 71152 03/10/2014 03/14/2014 TI 182

- DEGRAD UNDERGROUND PIPING - PHASE 2

1 IP Review of the Implementation of the Industry Initiative to Control Degradation of Underground Piping 2515/182 03/17/2014 03/21/2014 7111108P

- INSERVICE INSPECTION

1 IP Inservice Inspection Activities - PWR 7111108P 04/07/2014 04/18/2014 71124

- HP INSPECTION IP 71124.01, 02, 03 & 04

1 IP Radiological Hazard Assessment and Exposure Controls 71124.01 04/14/2014 04/18/2014

IP Occupational ALARA Planning and Controls 71124.02 04/14/2014 04/18/2014

IP In-Plant Airborne Radioactivity Control and Mitigation 71124.03 04/14/2014 04/18/2014

IP Occupational Dose Assessment 71124.04 04/14/2014 04/18/2014 71124

- RAD MONITORING INSTRUMENTATION

1 IP Radiation Monitoring Instrumentation 71124.05 05/19/2014 05/23/2014 TRI FI

- TRIENNIAL FIRE PROTECTION

1 IP Fire Protection [Triennial]

7111105T 06/23/2014 06/27/2014

IP Fire Protection [Triennial]

7111105T 07/07/2014 07/11/2014 71152B

- PI&R BIENNIAL

1 IP Problem Identification and Resolution 71152B 10/06/2014 10/10/2014

IP Problem Identification and Resolution 71152B 10/20/2014 10/24/2014 71124.08

- RADWASTE

1 IP Radioactive Solid Waste Processing and Radioactive Material Handling, Storage, and Transportation 71124.08 08/18/2014 08/22/2014 ASR

- PI&R SAMPLE - ASR MONITORING

1 IP Problem Identification and Resolution 71152 09/15/2014 09/19/2014 EP EXER

- EP EXERCISE INSPECTION

1 IP Exercise Evaluation - Hostile Action (HA) Event 7111407 11/03/2014 11/07/2014 323EXAM

- SEABROOK INITIAL EXAM

1 FY15-SEABROOK INITIAL OPERATOR LICENSING EXAM U01915 02/23/2015 03/27/2015

FY15-SEABROOK INITIAL OPERATOR LICENSING EXAM U01915 03/23/2015 04/04/2015 71151

- 71151PI VERIFY71124.01,.02,.03,.04 CLEAN

1 IP Radiological Hazard Assessment and Exposure Controls 71124.01 12/08/2014 12/12/2014 This report does not include INPO and OUTAGE activities.

This report shows only on-site and announced inspection procedures.

Page 2 of 2 02/27/2014 13:55:57 Report 22 Unit Number Planned Dates Start End Inspection Activity Title No. of Staff on Site Seabrook Inspection / Activity Plan 01/01/2014 - 06/30/2015 71151

- 71151PI VERIFY71124.01,.02,.03,.04 CLEAN

1 IP Occupational ALARA Planning and Controls 71124.02 12/08/2014 12/12/2014

IP In-Plant Airborne Radioactivity Control and Mitigation 71124.03 12/08/2014 12/12/2014

IP Occupational Dose Assessment 71124.04 12/08/2014 12/12/2014

IP Occupational Exposure Control Effectiveness 71151-OR01 12/08/2014 12/12/2014

IP RETS/ODCM Radiological Effluent 71151-PR01 12/08/2014 12/12/2014 ASR

- PI&R SAMPLE - ASR MONITORING

1 IP Problem Identification and Resolution 71152 03/02/2015 03/06/2015 MODS

- PERMANENT PLANT MODIFICATIONS

1 IP Evaluations of Changes, Tests, and Experiments and Permanent Plant Modifications 7111117T 03/02/2015 03/06/2015

IP Evaluations of Changes, Tests, and Experiments and Permanent Plant Modifications 7111117T 03/16/2015 03/20/2015 ISFSI

- ISFSI OPERATION INSPECTION

1 IP Operation Of An ISFSI 60855 04/13/2015 04/17/2015

IP Operation of an Independent Spent Fuel Storage Installation at Operating Plants 60855.1 04/13/2015 04/17/2015 71124

- RAD EFFLUENT CONTROL RETS

1 IP Radioactive Gaseous and Liquid Effluent Treatment 71124.06 04/20/2015 04/23/2015 7111107T

- TRIENNIAL HEAT SINK

1 IP Heat Sink Performance 7111107T 06/01/2015 06/05/2015 This report does not include INPO and OUTAGE activities.

This report shows only on-site and announced inspection procedures.