MONTHYEARML23349A0272023-12-15015 December 2023 Acceptance of Requested Licensing Action License Amendment Request to Revise Technical Specification 5.5.2 ML23284A3322023-10-11011 October 2023 Request for Additional Information Alternative Request (RA-22-0174) (L-2022-LLR-0060) ML23270B8362023-09-26026 September 2023 Code Case N-752 Audit September 26, 2023, E-mail Providing Additional Information Regarding the Use of Owner'S Requirements and Engineering Judgment in Lieu of Code and Standards ML23267A0032023-09-21021 September 2023 RP Inspection Document Request ML23269A0412023-08-22022 August 2023 Code Case N-752 Audit; August 22, 2023, E-mail Providing Additional Information Regarding Design and Quality Program Requirements ML23172A0132023-06-20020 June 2023 Duke Fleet - Correction to June 2, 2023, Request for Additional Information Proposed License Amendment Request to Revise Restrictive Surveillance Requirement Frequencies ML23153A1892023-06-0202 June 2023 Duke Fleet - Request for Additional Information Proposed License Amendment Request to Revise Restrictive Surveillance Requirement Frequencies ML23151A3482023-05-30030 May 2023 Duke Fleet - Request for Additional Information Proposed Alternative for Pressurizer Welds in Accordance with 10 CFR 50.55a(z)(1) ML23144A0862023-05-24024 May 2023 Acceptance of Requested Licensing Action Proposed Relief Request (RA-23-0018) to Use ASME Code Case 853 ML23142A2732023-05-22022 May 2023 Duke Fleet - Request for Additional Information Proposed Alternative for Steam Generator Welds in Accordance with 10 CFR 50.55a(z)(1) ML23125A1452023-05-0505 May 2023 Change in Estimated Review Schedule and Level of Effort for Proposed Alternative to Use Code Case N-752 ML23124A1212023-05-0404 May 2023 Acceptance of Requested Licensing Action Duke Fleet Proposed Alternative for Pressurizer Welds in Accordance with 10 CFR 50.55a(z)(1) ML23095A0052023-04-0404 April 2023 002 Radiation Safety Baseline Inspection Information Request ML23086C0362023-03-27027 March 2023 Request for Additional Information Steam Generator Tube Inspection Report (03R31) ML23073A2282023-03-13013 March 2023 Duke Fleet- Adoption of TSTF-554, Revision 1, Revise Reactor Coolant Leakage Requirements - Acceptance Review ML23058A0562023-02-27027 February 2023 Acceptance of Amendment to Revise Surveillance Frequencies for RCS Pressure Isolation Valve Operational Leakage Testing and Reactor Trip System Instrumentation ML23048A1512023-02-16016 February 2023 Acceptance Review - Proposed Alternative for Steam Generator Welds (L-2023-LLR-0003) ML23038A1832023-02-0707 February 2023 Request for Additional Information Alternative Request (RA-22-0174) to Use ASME Code Case N-752 ML23031A1552023-01-17017 January 2023 1/17/2023 Email from John Moses, Deputy Director, Division of Rulemaking, Environmental, and Financial Support, to Diane Curran, Counsel to Beyond Nuclear and the Sierra Club, Request for Extension of Scoping Comment Period for Oconee EIS ML22294A0812022-10-21021 October 2022 Nrc/Duke Steam Generator Inspection Call for November 8, 2022 NRC-2100-2022, EN 55999 Valcor Coil Shell Assemblies Final Notification (004)2022-09-12012 September 2022 EN 55999 Valcor Coil Shell Assemblies Final Notification (004) ML22251A2902022-09-0808 September 2022 Request for Additional Information Additional Mode Change Limitations Applicable to the Adoption of Technical Specifications Tasks Force Traveler (TSTF) No. 359, Revision 9 ML22235A6552022-08-23023 August 2022 Acceptance of Requested Licensing Action Proposed Alternative to Use ASME Code Case N-752 NRC 2110-2022, EN 55999 - Valcor Engineering Corporation (009)2022-07-18018 July 2022 EN 55999 - Valcor Engineering Corporation (009) ML22234A1262022-07-0808 July 2022 Email from NRC to Duke - Feedback on Trp 76 RAI Responses - July 8, 2022 ML22234A1272022-06-14014 June 2022 Email from NRC to Duke - Feedback on Trp 76 RAI Responses - June 14, 2022 ML22154A2142022-06-0101 June 2022 Email from NRC (Angela Wu) to Duke (Paul Guill) - Oconee SLRA - 2nd Round RAI B2.1.7-4b ML22157A0012022-06-0101 June 2022 Email from NRC (Angela Wu) to Duke (Paul Guill) - Oconee SLRA - Additional NRC Comments on RAI 4.6.1-1a ML22124A2052022-05-0404 May 2022 Summary of May 4, 2022, Clarification Call with Duke Energy Carolinas, LLC, Application to Revise TS 3.7.7, Low Pressure Service Water (LPSW) System ML22124A1612022-05-0303 May 2022 Email from Angela Wu (NRC) to Steve Snider (Duke) - Oconee SLRA - 2nd Round RAI B2.1.7-4a ML22122A0192022-04-28028 April 2022 Email from Angela Wu (NRC) to Steve Snider (Duke) - Oconee SLRA - 2nd Round RAI B2.1.9-2a ML22122A1322022-04-27027 April 2022 Email from Angela Wu (NRC) to Steve Snider (Duke) - Oconee SLRA - 2nd Round Requests for Additional Information (FE 3.5.2.2.2.6 - Irradiation Structural) ML22115A1412022-04-25025 April 2022 NRR E-mail Capture - Duke Common EOF Relocation - Request for Addition Information ML22130A0112022-04-25025 April 2022 Email: Oconee SLRA - RAI 4.6.1-1a - NRC Staff Comments ML22112A1892022-04-22022 April 2022 Acceptance Review for Additional Mode Change Limitations Applicable to the Adoption of TSTF- 359, Revision 9 ML22112A0072022-04-20020 April 2022 Email from Marieliz Johnson (NRC) to Steve Snider (Duke) - Oconee SLRA - Request for Confirmation of Information 3.5.2.2.2.6-L ML22113A0082022-04-20020 April 2022 Email from Marieliz Johnson (NRC) to Steve Snider (Duke) - Oconee SLRA - Request for Additional Information 3.1.2-1 ML22088A0452022-03-28028 March 2022 Radiation Safety Baseline Inspection Initial Information Request Inspection Report 2022002 ML22081A0052022-03-21021 March 2022 Email from Angela Wu (NRC) to Steve Snider (Duke) - Oconee SLRA - 2nd Round RAI B4.1-3 ML22080A0792022-03-16016 March 2022 Email from Angela Wu (NRC) to Steve Snider (Duke) - Oconee SLRA - Requests for Additional Information - Set 4 (2nd Round Rais) ML22075A2032022-03-11011 March 2022 Email from Duke to NRC - Follow-Up Items from March 7, 2022 Public Meeting ML22074A0022022-03-11011 March 2022 Email from Duke to NRC - Follow-up Item from March 7, 2022 Public Meeting - SSW Tendon AMP ML22069A0022022-03-0808 March 2022 Email from Angela Wu (NRC) to Steve Snider (Duke) - Oconee SLRA - Requests for Confirmation of Information - Set 4 ML22063A4502022-03-0404 March 2022 Request for Additional Information Application to Revise TS 3.7.7, Low Pressure Service Water (LPSW) System, to Extend the Completion Time for One Required Inoperable LPSW Pump ML22063A1152022-02-23023 February 2022 Email from Duke to NRC - Follow Up Item from February 17, 2022 Public Meeting ML22038A1572022-02-0707 February 2022 NRR E-mail Capture - Duke Energy Fleet - Acceptance of License Amendment Request Regarding Adoption of TSTF-541, Revision 2 ML22035A1892022-01-31031 January 2022 Email from NRC (Angela Wu) to Duke (Paul Guill) - Oconee SLRA - Request for Public Meeting ML22018A0272022-01-18018 January 2022 2022 All RFI Responses - Exercise and Program Inspections - Revl ML22019A1032022-01-18018 January 2022 Email from Angela Wu (NRC) to Steve Snider (Duke) - Oconee SLRA - Requests for Additional Information - Set 3 ML22012A0432022-01-11011 January 2022 SLRA - Requests for Additional Information - Set 2 2023-09-26
[Table view] |
Text
Mitman, Jeffrey From: Mitman, Jeffrey I IJ *'
Sent: Tuesday, November 09, 2010,9:04 PM To: Ferrante, Fernando * ,
Subject:
Jocassee inflow calc Attachments: Reservoir Volumes (2).xlsx Fernando, attached is my revised spreadsheet.
With the additional data at the elevations of interest (1106 to 1125) I've re-plotted just this portion of the basin curve. According to Excel the curve is linear in this region. Let me know what you think.
I've also plotted the surface area based on the available data.
I've tried to reproduce the max inflow (inflow + rain water) equal to 522,000 using the HECI detailed output.
But I cannot get the 378,282 cfs plus the 0.53 in./hr. near the known total of 522,000. Ifyou've got time to kill, you can look at "Sheet2" of the spreadsheet to see my attempts.
However, looking through the output, I have found the composite parts. The HECI flood routing output shows a max total inflow of 522,734 (at time 40.33) with a max total routing of 378,282 (at time 40.50) and a max direct (rain) of 157,680 (at time 40.17), or: 378,282 + 157,680 = 535,962. This is close enough for me to the stated value of 522,734. I attribute the discrepancy to the difference in the times of the various maximums.
Jeff 1
se sa sq se Computed surface total elevation Storage discharge area discharge (ft. MSL) Volume (acre from spillway (acre) (SCFM) ft) 70,000 1 760 0 0 1080 60,000 2 780 180 1,200 0 1105.99 3 820 650 16,827 26,600 1106 0 50,000 4 860 1500 58,660 26,600 1110.99 0 40,000 5 900 2450 136,887 67,475 1111 40,875 30,000 6 940 3450 254,318 69,074 1112 42,474 7 980 4350 409,970 72,295 1114 45,695 20,000 8 1020 5300 602,658 75,539 1116 48,939 10,000 9 1060 6250 833,397 78,801 1118 52,201 10 1100 7250 1,103,150 82,076 1120 55,476 11 1123 7500 1,272,767 85,359 1122 58,759 12 1123.5 1,276,518 87,822 1123.5 61,222 isannon1 I -F surface area (acre) torage Capacit 8000 1,340,000 7000 Y= 11 1,320,000 6000 1,300,000 1,280,000 5000 1,260,000 4000 surface area (acre) 1,240,000 3000 1,220,000 -
2000 1,200,000 1000 1,180,000 950 1,160,000 --
0 750 850 950 1050 1,140,000 --
1,120,000
Spillway Discharge Curve Elevation Storage Capacity 760 780 1,200 820 16,827 860 58,660 900 136,887 Y= 1628.5x - 2E+06 940 254,318 D2- i 980 409,970 1020 602,658 1060 833,397 1100 1,103,150 L110 1112 1114 1116 1118 1120 1122 1124 1126 1128 1106 1,146,702 1107. 1,154,51 118 ,161,495 1113.8 1204254 1106.2 1,222,252 1120.17 1,250,912.
V1121.1 71,258,243 1123 1,272,767 1123.5 1,276,518 1125 [ ,8 788"i 1130 1125.5 1126
Excel Mitman Fernando (152,147) 9,863 13,240 (161,305) 705 2,460 105.00%
(152,073) 9,937 8,860 -47.35%
(106,111) 55,899 52,540 -10.43%
(23,420) 138,590 133,500 -2.47%
96,001 258,011 251,740 -1.01%
252,151 414,161 407,260 -0.66%
445,031 607,041 600,060 -0.43%
674,641 836,651 830,140 -0.39%
940,980 1,102,990 1,097,500 -0.51%
984,099 1,146,109 1,140,819 -0.51%
991,366 1,153,376 1,148,121 -0.53%
998,655 1,160,665 1,155,446 -0.52%
1,013,304 1,175,314 1,170,165 -0.46%
1,030,263 1,192,273 1,187,208 -0.51%
1,041,389 1,203,399 1,198,389 -0.49%
1,059,297 1,221,307 1,216,387 -0.48%
1,074,322 1,236,332 1,231,489 -0.44%
1,088,681 1,250,691 1,245,922 -0.40%
1,096,271 1,258,281 1,253,552 -0.37%
1,103,123 1,265,133 1,260,439 -0.38%
1,110,757 1,272,767 1,268,113 -0.37%
1,114,582 1,276,592 1,271,959 -0.36%
1,126,094 1,288,104 1,283,531 -0.33%
1,164,838 1,326,848 1,322,485 1,129,942 1,291,952 1,287,400 1,133,797 1,295,807 1,291,275