Enclosures 1-3, Description of AMP Changes for Callaway Plant Unit 1 License Renewal Application Amendment No. 1
ML121170323
Person / Time
Site: Callaway 
Issue date: 04/25/2012
From:
Ameren Missouri, Union Electric Co
To:
Office of Nuclear Reactor Regulation
Shared Package
ML121170324 List:
References
ULNRC-05856
Download: ML121170323 (122)


Text

ENCLOSURE 1 Description of AMP Changes for Callaway Plant Unit 1 License Renewal Application Amendment No. 1 Callaway LRA Amendment 1 Changes Related to Aging Management Programs (AMPs)

AMP XI.M2 (B2.1.2) Water Chemistry Affected LRA Sections A1.2, Water Chemistry Reason for Change Remove EPRI guideline revision references from LRA Appendix A.

AMP XI.M11B (B2.1.5) Cracking of Nickel-Alloy Components and Loss of Material Due to Boric Acid-Induced Corrosion in Reactor Coolant Pressure Boundary Components Affected LRA Section B2.1.5, Cracking of Nickel-Alloy Components and Loss of Material Due to Boric Acid-Induced Corrosion in Reactor Coolant Pressure Boundary Components Reason for Change Revise operating experience (OE) item 1.

AMP XI.M16A (B2.1.6) PWR Vessel Internals Affected LRA Section Table 2.3.1-1 Section 3.1.2.2.9 Section 3.1.2.2.10 Table 3.1.2-1 A1.6, PWR Vessel Internals B2.1.6, PWR Vessel Internals Reason for Change Incorporate EPRI 1022863 ( MRP-227-A) and MRP-227 Safety Evaluation Callaway LRA Amendment 1 AMP XI.M18 (B2.1.8) Bolting Integrity Affected LRA Section A1.8, Bolting Integrity Table A4-1 item 5 B2.1.8 Bolting Integrity Reason for Change Correct typo in Appendix A: EPRI NP 403213 should be EPRI TR 403213 The enhancement to reference NUREG-1339 and EPRI NP-5769 to be consistent with NUREG-1801 in the Bolting Integrity program has been completed AMP XI.M19 (B2.1.9) Steam Generators Affected LRA Section B2.1.9, Steam Generators Reason for Change Revise operating experience (OE) item 1.

AMP XI.M23 (B2.1.12) Inspection of Overhead Heavy Load and Light Load (Related to Refueling) Handling Systems Affected LRA Section 2.3.3.3, system description for Cranes, Hoist and Elevators Reason for Change A recent plant modification has been competed to install a hoist and trolley for the north head of the component cooling water heat exchanger AMP XI.M26 (B2.1.13) Fire Protection Affected LRA Section Table 2.3.3-15, Miscellaneous Buildings HVAC System Section 3.3.2.1.11, Control Building HVAC System Section 3.3.2.1.13, Auxiliary Building HVAC System Section 3.3.2.1.14, Fuel Building HVAC System Section 3.3.2.1.15, Miscellaneous Buildings HVAC System Section 3.3.2.1.17, Radwaste Building HVAC System Section 3.3.2.1.18, Turbine Building HVAC System Table 3.3-1 item 90 Table 3.3.2-11 Callaway LRA Amendment 1 Table 3.3.2-13 Table 3.3.2-14 Table 3.3.2-15 Table 3.3.2-17 Table 3.3.2-18 Table A4-1 item 9 B2.1.13, Fire Protection Reason for Change Fire dampers were added to the scope of the Fire Protection program.

The enhancement for trending of Halon system testing was removed since trending is accomplished by the corrective action process and operating experience.

AMP XI.M27 (B2.1.14) Fire Water System Affected LRA Section A1.14, Fire Water System Table A4-1 item 10 B2.1.14, Fire Water System Reason for Change Added new operating experience (OE) item 5.

Clarified that pipe wall thickness measurements are performed by non-intrusive techniques.

AMP XI.M29 (B2.1.15) Aboveground Metallic Tanks Affected LRA Section A1.15, Aboveground Metallic Tanks B2.1.15, Aboveground Metallic Tanks Reason for Change Revised operating experience (OE) item 1 to include 2011 experience.

Added preventative measures to LRA Appendix A.

AMP XI.M38 (B2.1.23) Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components Affected LRA Section B2.1.23, Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components Reason for Change Revise operating experience (OE) item 2.

Callaway LRA Amendment 1 AMP XI.E2 (B2.1.35) Insulation Material for Electrical Cables and Connections Not Subject to 10 CFR 50.49 Environmental Qualification Requirements Used in Instrumentation Circuits Affected LRA Section A1.35, Insulation Material for Electrical Cables and Connections Not Subject to 10 CFR 50.49 Environmental Qualification Requirements Used in Instrumentation Circuits Table A4-1 item 26 B2.1.35, Insulation Material for Electrical Cables and Connections Not Subject to 10 CFR 50.49 Environmental Qualification Requirements Used in Instrumentation Circuits Reason for Change Consistently describe testing as surveillances The enhancement was revised to include a separate enhancement for element 7 corrective actions.

AMP XI.E3 (B2.1.36) Inaccessible Power Cables Not Subject to 10CFR50.49 Environmental Qualification Requirements Affected LRA Section A1.36, Inaccessible Power Cables Not Subject to 10CFR50.49 Environmental Qualification Requirements Table A4-1 item 27 B2.1.36, Inaccessible Power Cables Not Subject to 10CFR50.49 Environmental Qualification Requirements Reason for Change Revise AMP to reflect use of recently installed sump pump modification on some of the in-scope manholes AMP XI.E4 (B2.1.39) Metal Enclosed Bus Affected LRA Section A1.39, Metal Enclosed Bus B2.1.39, Metal Enclosed Bus Reason for Change Revise operating experience (OE) item 1.

Revise the AMP to indicate that a sample of the accessible bolted connections will be inspected by a visual inspection of the insulating material

ENCLOSURE 2 Callaway Plant Unit 1 License Renewal Application Amendment No. 1 AMP Changes

Callaway LRA Amendment 1 Affected Pages LRA Section AMP Page Nos Table 2.3.1-1 XIM16A 2.3-5 2.3.3.3 XI.M23 2.3-31 Table 2.3.3-15 XI.M26 2.3-56 3.1.2.2.9 XI.M16A 3.1-11 3.1.2.2.10 XI.M16A 3.1-12 Table 3.1.2-1 XI.M16A 3.1-74, 75, 81, 83, 85 3.3.2.1.11 XI.M26 3.3-16 3.3.2.1.13 XI.M26 3.3-18 3.3.2.1.14 XI.M26 3.3-19 3.3.2.1.15 XI.M26 3.3-20 3.3.2.1.17 XI.M26 3.3-22 3.3.2.1.18 XI.M26 3.3-23 Table 3.3-1 XI.M26 3.3-66 Table 3.3.2-11 XI.M26 3.3-149 Table 3.3.2-13 XI.M26 3.3-164 Table 3.3.2-14 XI.M26 3.3-173 Table 3.3.2-15 XI.M26 3.3-183 Table 3.3.2-17 XI.M26 3.3-193 Table 3.3.2-18 XI.M26 3.3-195 A1.2 XI.M2 A-2 A1.6 XI.M16A A-4 A1.8 XI.M18 A-5 A1.14 XI.M27 A-8 A1.15 XI.M29 A-8 A1.35 XI.E2 A-18 A1.36 XI.E3 A1-18 to A1-19 A1.39 XI.E4 A1-20 Table A4-1 XI.M18 A-37

LRA Section AMP Page Nos Table A4-1 XI.M26 A-38 Table A4-1 XI.M27 A-38 Table A4-1 XI.E2 A-44 Table A4-1 XI.E3 A-45 B2.1.5 XI.M11B B-25 to B-27 B2.1.6 XI.M16A B-28 to B-30 B2.1.8 XI.M18 B-34 to B-37 B2.1.9 XI.M19 B-38 to B-40 B2.1.13 XI.M26 B-50 to B-52 B2.1.14 XI.M27 B-53 to B-56 B2.1.15 XI.M29 B-57 to B-59 B2.1.23 XI.M38 B-81 to B83 B2.1.35 XI.E2 B116-B117 B2.1.36 XI.E3 B118-B120 B2.1.39 XI.E4 B125-B126

Callaway Plant License Renewal Application Amendment 1 Revision to add RVI Core Barrel Girth Welds and RVI Core Barrel Axial Welds/Outlet Nozzle Welds.

Table 2.3.1-1 (page 2.3-5) is revised as follows (new text shown underlined):

Table 2.3.1-1 Reactor Vessel and Internals (Continued)

Component Type Intended Function RVI Core Barrel Girth Welds and Flange Welds Direct Flow Shielding Structural Support RVI Core Barrel Axial Welds/Outlet Nozzle Welds Direct Flow Shielding Structural Support

Callaway Plant License Renewal Application Amendment 1 Revision to system description to add the hoist and trolley for the north head of the component cooling water heat exchanger Section 2.3.3.3 (page 2.3-31) is revised as follows (new text shown underlined):

2.3.3.3 Cranes, Hoists, and Elevators

System Description

The purpose of the cranes, hoists and elevators system is to provide lifting and maneuvering capacity in Category I structures and various nonsafety-related buildings about the site. The cranes, hoists and elevators system is nonsafety and performs no safety-related functions.

The cranes, hoists and elevators system consists of multiple cranes, doors, elevators, hoists and trolleys. The following cranes, hoists and monorails are within the scope of license renewal:

Containment jib cranes Containment pressurizer enclosure wall jib crane Hoist and trolley for the south head on component cooling water heat exchanger Trolley for the north head on component cooling water heat exchanger Diesel generator under-hung monorails and bridge crane Fuel pool cooling pumps monorails and hoists Auxiliary building filter room monorail and hoist Auxiliary feedwater pump monorails and hoists Component cooling water pump monorails and hoists Component cooling water surge tank area monorails and hoists Centrifugal charging pump monorails and hoists Safety injection pump monorails and hoists RHR pump monorails and hoists Containment spray pump monorails and hoist Normal charging pump monorail and hoists Auxiliary building HVAC monorail and hoist Main steam relief and isolation valve monorails and hoists Resin charging tank area monorail and hoist Reactor building elevator auxiliary monorail and hoist Boric acid batch tank monorail and hoist Containment equipment hatch radiation and missile shield hand trolley Feed regulating valve rigging trolley Trolley beams for miscellaneous equipment Crane rail supports are evaluated with their appropriate structure in Section 2.4, Scoping and Screening Results: Structures.

Callaway Plant License Renewal Application Amendment 1 Revision to add the Fire Barrier as an intended function for component type Damper Table 2.3.3-15 (page 2.3-56) is revised as follows (new text shown underlined):

Table 2.3.3-15 Miscellaneous Buildings HVAC System Component Type Intended Function Damper Fire Barrier Pressure Boundary

Callaway Plant License Renewal Application Amendment 1 Revision to further evaluation to add MRP-227-A safety evaluation requirements.

Further evaluation 3.1.2.2.9 (page 3.1-11) is revised as follows (deleted text shown in strikethrough and new text shown underlined):

3.1.2.2.9 Cracking due to Stress Corrosion Cracking and Irradiation-Assisted Stress Corrosion Cracking PWR Vessel Internals (B2.1.6) examines one hundred percent of the accessible volume/area of each component for the Primary and Expansion components inspection category components. The minimum examination coverage for primary and expansion inspection categories is 75 percent of the component's total (accessible plus inaccessible) inspection area/volume be examined. When addressing a set of like components (e.g. bolting), the minimum examination coverage for primary and expansion inspection categories is 75 percent of the component's total population of like components (accessible plus inaccessible).

If defects are discovered during the examination, Callaway will enter the information into the corrective action program and evaluate whether the results of the examination ensure that the component (or set of components) will continue to meet its intended function under all licensing basis conditions of operation until the next scheduled examination. Engineering evaluations that demonstrate the acceptability of a detected condition will be performed consistent with WCAP-17096-NP.one hundred percent of the volume/area of each accessible stainless steel and nickel alloy reactor vessel internals primary and expansion inspection category component that is subject to cracking. The minimum examination coverage for primary and expansion inspection categories is 75 percent of the component's total (accessible plus inaccessible) inspection area/volume be examined or, when addressing a set of like components (e.g., bolting), that the inspection examine a minimum sample size of 75 percent of the total population of like components.

If defects are discovered in the 75 percent sample size, the information will be entered into corrective action program to evaluate the results of the examination to ensure the intended functions are maintained until the next scheduled examination.

Callaway Plant License Renewal Application Amendment 1 Revision to further evaluation to add MRP-227-A safety evaluation requirements.

Further evaluation 3.1.2.2.10 (page 3.1-12) is revised as follows (deleted text shown in strikethrough and new shown text underlined):

3.1.2.2.10 Loss of Fracture Toughness due to Neutron Irradiation Embrittlement; Change in Dimension due to Void Swelling; Loss of Preload due to Stress Relaxation; or Loss of Material due to Wear PWR Vessel Internals (B2.1.6) examines one hundred percent of the accessible volume/area of each component for the Primary and Expansion components inspection category components. The minimum examination coverage for primary and expansion inspection categories is 75 percent of the component's total (accessible plus inaccessible) inspection area/volume be examined. When addressing a set of like components (e.g. bolting), the minimum examination coverage for primary and expansion inspection categories is 75 percent of the component's total population of like components (accessible plus inaccessible).

If defects are discovered during the examination, Callaway will enter the information into the corrective action program and evaluate whether the results of the examination ensure that the component (or set of components) will continue to meet its intended function under all licensing basis conditions of operation until the next scheduled examination. Engineering evaluations that demonstrate the acceptability of a detected condition will be performed consistent with WCAP-17096-NP.one hundred percent of the volume/area of each accessible stainless steel and nickel alloy reactor vessel internals primary and expansion inspection category component that is subject to loss of fracture toughness, changes in dimension, loss of preload, or loss of material. The minimum examination coverage for primary and expansion inspection categories is 75 percent of the component's total (accessible plus inaccessible) inspection area/volume be examined or, when addressing a set of like components (e.g., bolting), that the inspection examine a minimum sample size of 75 percent of the total population of like components.

If defects are discovered in the 75 percent sample size, the information will be entered into corrective action program to evaluate the results of the examination to ensure the intended functions are maintained until the next scheduled examination.

Callaway Plant License Renewal Application Amendment 1 Revision to Table 3.1.2-1 to add MRP-227-A safety evaluation requirements.

Table 3.1.2-1 (pages 3.1-74, 75, 81, 83 and 85) are revised as follows (deleted text shown in strikethrough and new text shown underlined):

Table 3.1.2-1 Reactor Vessel, Internals, and Reactor Coolant System - Summary of Aging Management Evaluation - Reactor Vessel and Internals (Continued)

Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Program NUREG-1801 Item Table 1 Item Notes RVI Core Barrel Axial Welds/Outlet Nozzle Welds DF, SLD, SS Stainless Steel Reactor Coolant (Ext)

Loss of material Water Chemistry (B2.1.2)

IV.B2.RP-24 3.1.1.087 A

RVI Core Barrel Axial Welds/Outlet Nozzle Welds DF, SLD, SS Stainless Steel Reactor Coolant (Ext)

Cracking Water Chemistry (B2.1.2) and PWR Vessel Internals (B2.1.6) (Expansion Components)

IV.B2.RP-278 3.1.1.053 A

RVI Core Barrel Axial Welds/Outlet Nozzle Welds DF, SLD, SS Stainless Steel Reactor Coolant (Ext)

Cracking Water Chemistry (B2.1.2) and PWR Vessel Internals (B2.1.6) (Expansion Components)

IV.B2.RP-387 3.1.1.053 A

RVI Core Barrel Axial Welds/Outlet Nozzle Welds DF, SLD, SS Stainless Steel Reactor Coolant (Ext)

Loss of fracture toughness PWR Vessel Internals (B2.1.6) (Expansion Components)

IV.B2.RP-388 3.1.1.059 A

Table 3.1.2-1 Reactor Vessel, Internals, and Reactor Coolant System - Summary of Aging Management Evaluation - Reactor Vessel and Internals (Continued)

Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Program NUREG-1801 Item Table 1 Item Notes RVI Core Barrel Flanges DF, SLD, SS Stainless Steel Reactor Coolant (Ext)

Cracking Water Chemistry (B2.1.2) and PWR Vessel Internals (B2.1.6) (Expansion Components)ASME Section XI Inservice Inspection, Subsections IWB, IWC, and IWD (B2.1.1)

IV.B2.RP-282 IV.B2.RP-382 3.1.1.053 3.1.1.032 A

RVI Core Barrel Girth Welds and Flange Welds RVI Core Barrel Welds and Flange Welds DF, SLD, SS Stainless Steel Reactor Coolant (Ext)

Loss of material Water Chemistry (B2.1.2)

IV.B2.RP-24 3.1.1.087 A

RVI Core Barrel Girth Welds and Flange Welds RVI Core Barrel Welds and Flange Welds DF, SLD, SS Stainless Steel Reactor Coolant (Ext)

Cracking Water Chemistry (B2.1.2) and PWR Vessel Internals (B2.1.6) (Primary Components - Requires Expansion Components)

IV.B2.RP-276 3.1.1.053 C, 3

Table 3.1.2-1 Reactor Vessel, Internals, and Reactor Coolant System - Summary of Aging Management Evaluation - Reactor Vessel and Internals (Continued)

Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Program NUREG-1801 Item Table 1 Item Notes RVI Core Barrel Girth Welds and Flange Welds RVI Core Barrel Welds and Flange Welds DF, SLD, SS Stainless Steel Reactor Coolant (Ext)

Loss of fracture toughness PWR Vessel Internals (B2.1.6) (Primary Components - Requires Expansion Components)

IV.B2.RP-297 3.1.1.059 C, 3 RVI Lower Core Support-Core Support Forging SS Stainless Steel Reactor Coolant (Ext)

Loss of fracture toughness PWR Vessel Internals (B2.1.6) (Expansion Components)

IV.B2.RP-292 3.1.1.059 C, 4 RVI Upper Core Support-Upper Core Plate SS Stainless Steel Reactor Coolant (Ext)

Loss of fracture toughness PWR Vessel Internals (B2.1.6) (Expansion Components)

IV.B2.RP-292 3.1.1.059 C, 4 RVI Upper Core Support-Upper Core Plate SS Stainless Steel Reactor Coolant (Ext)

Loss of material PWR Vessel Internals (B2.1.6) (Expansion Components)

IV.B2.RP-386 3.1.1.059 C, 4 Notes for Table 3.1.2-1:

Standard Notes:

A Consistent with NUREG-1801 item for component, material, environment, and aging effect. AMP is consistent with NUREG-1801 AMP.

C Component is different, but consistent with NUREG-1801 item for material, environment, and aging effect. AMP is consistent with NUREG-1801 AMP.

E Consistent with NUREG-1801 for material, environment, and aging effect, but a different aging management program is credited or NUREG-1801 identifies a plant-specific aging management program.

F Material not in NUREG-1801 for this component.

Plant Specific Notes:

1 NUREG-1801 does not address cracking of the nickel-alloy reactor vessel flange leak monitoring tube with an internal environment of reactor coolant leakage. The ASME Section XI Inservice Inspection, Subsections IWB, IWC, and IWD program (B2.1.1) manages the cracking of the nickel-alloy reactor vessel flange leak monitoring tube with an internal environment of reactor coolant leakage.

2 The plant-specific aging management programs used to manage the cracking for stainless steel BMI guide tubes are ASME Section XI Inservice Inspection, Subsections IWB, IWC, and IWD (B2.1.1) for Class 1 components and Water Chemistry (B2.1.2).

3 The MRP-227 Safety Evaluation section 4.1, Limitations and Conditions specifies that the core barrel flange welds need to be assigned as primary components for aging management of IASCC and neutron embrittlement. The core barrel cylinder girth (circumferential) welds component is managed as a primary component consistent with MRP-227-A, Table 4-3.The MRP-227 Safety Evaluation specifies that the upper and lower core barrel welds and lower core barrel flange welds need to be made primary components for IASCC and neutron embrittlement. The reactor vessel internal core barrel welds & flange welds component includes all core barrel welds (upper core barrel flange weld, lower core barrel flange weld, and upper and lower core barrel welds). The reactor vessel internal core barrel welds and flange welds component is managed as an MRP-227 primary component and linked to reactor vessel internal lower core support column bodies as an expansion component.

4 This reactor vessel internal expansion component is linked to the MRP-227-A primary component of CRGT lower flange weld, as specified in MRP-227 Safety Evaluation section 4.1, Limitations and Conditions. This reactor vessel internal expansion component is linked to the MRP-227 primary component of control rod guide tube lower flange weld, as specified in MRP-227 Safety Evaluation section 4.1, Limitations and Conditions.

Callaway Plant License Renewal Application Amendment 1 Addition of the Fire Protection AMP in the systems noted below.

The following systems are revised as follows (new text shown underlined):

  • Section 3.3.2.1.11, Control Building HVAC System, (Page 3.3-16)
  • Section 3.3.2.1.13, Auxiliary Building HVAC System, (Page 3.3-18)
  • Section 3.3.2.1.14, Fuel Building HVAC System, (Page 3.3-19)
  • Section 3.3.2.1.15, Miscellaneous Buildings HVAC System, (Page 3.3-20)
  • Section 3.3.2.1.17, Radwaste Building HVAC System, (Page 3.3-22)
  • Section 3.3.2.1.18, Turbine Building HVAC System, (Page 3.3-23) 3.3.2.1.11 Control Building HVAC System Aging Management Programs The following aging management programs manage the aging effects for the control building HVAC system component types:

Bolting Integrity (B2.1.8)

Closed Treated Water Systems (B2.1.11)

External Surfaces Monitoring of Mechanical Components (B2.1.21)

Fire Protection (B2.1.13)

Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components (B2.1.23)

Open-Cycle Cooling Water System (B2.1.10) 3.3.2.1.13 Auxiliary Building HVAC System Aging Management Programs The following aging management programs manage the aging effects for the auxiliary building HVAC system component types:

Bolting Integrity (B2.1.8)

Closed Treated Water Systems (B2.1.11)

External Surfaces Monitoring of Mechanical Components (B2.1.21)

Fire Protection (B2.1.13)

Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components (B2.1.23)

Open-Cycle Cooling Water System (B2.1.10)

Selective Leaching (B2.1.19)

3.3.2.1.14 Fuel Building HVAC System Aging Management Programs The following aging management programs manage the aging effects for the fuel building HVAC system component types:

Bolting Integrity (B2.1.8)

Closed Treated Water Systems (B2.1.11)

External Surfaces Monitoring of Mechanical Components (B2.1.21)

Fire Protection (B2.1.13)

Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components (B2.1.23)

Open-Cycle Cooling Water System (B2.1.10)

Selective Leaching (B2.1.19) 3.3.2.1.15 Miscellaneous Buildings HVAC System Aging Management Programs The following aging management programs manage the aging effects for the miscellaneous buildings HVAC system component types:

Bolting Integrity (B2.1.8)

Closed Treated Water Systems (B2.1.11)

External Surfaces Monitoring of Mechanical Components (B2.1.21)

Fire Protection (B2.1.13)

Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components (B2.1.23)

Open-Cycle Cooling Water System (B2.1.10) 3.3.2.1.17 Radwaste Building HVAC System Aging Management Programs The following aging management programs manage the aging effects for the radwaste building HVAC system component types:

External Surfaces Monitoring of Mechanical Components (B2.1.21)

Fire Protection (B2.1.13)

Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components (B2.1.23)

3.3.2.1.18 Turbine Building HVAC System Aging Management Programs The following aging management programs manage the aging effects for the turbine building HVAC system component types:

Bolting Integrity (B2.1.8)

External Surfaces Monitoring of Mechanical Components (B2.1.21)

Fire Protection (B2.1.13)

Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components (B2.1.23)

Section 3.3 AGING MANAGEMENT OF AUXILIARY SYSTEMS Callaway Plant Unit 1 License Renewal Application Callaway Plant License Renewal Application Amendment 1 Revised to state that fire dampers are managed by the Fire Protection AMP.

Table 3.3-1, Summary of Aging Management Programs in Chapter VII of NUREG-1801 for Auxiliary Systems, (Page 3.3-66) is revised as follows (deleted text shown in strikethrough and new text underlined):

Table 3.3-1 Summary of Aging Management Programs in Chapter VII of NUREG-1801 for Auxiliary Systems Item Number Component Type Aging Effect / Mechanism Aging Management Program Further Evaluation Recommended Discussion 3.3.1.090 Steel Ducting and components (Internal surfaces) exposed to Condensation (Internal)

Loss of material due to general, pitting, crevice, and (for drip pans and drain lines) microbiologically-influenced corrosion Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components (B2.1.23)

No Consistent with NUREG-1801 with aging management program exceptions.

The aging management program(s) with exceptions to NUREG-1801 include:

Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components (B2.1.23). Aging management of dampers with a fire barrier intended function are managed by the Fire Protection program (B2.1.13).

Section 3.3 AGING MANAGEMENT OF AUXILIARY SYSTEMS Callaway Plant Unit 1 License Renewal Application Callaway Plant License Renewal Application Amendment 1 Revised Aging Management Program and Notes for the internal environment of Dampers; no new lines were added. New Plant Note added.

Table 3.3.2-11, Control Building HVAC System, (Page 3.3-149) is revised as follows (deleted text shown in strikethrough and new text underlined):

Table 3.3.2-11 Auxiliary Systems - Summary of Aging Management Evaluation -Control Building HVAC System Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Program NUREG-1801 Item Table 1 Item Notes Damper FB, PB Carbon Steel (Galvanized)

Ventilation Atmosphere (Int)

Loss of material Fire Protection (B2.1.13)

Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components (B2.1.23)

VII.F1.A-08 3.3.1.090 BE, 4 Notes for Table 3.3.2-11:

Standard Notes:

A Consistent with NUREG-1801 item for component, material, environment, and aging effect. AMP is consistent with NUREG-1801 AMP.

B Consistent with NUREG-1801 item for component, material, environment, and aging effect. AMP takes some exceptions to NUREG-1801 AMP.

C Component is different, but consistent with NUREG-1801 item for material, environment, and aging effect. AMP is consistent with NUREG-1801 AMP.

D Component is different, but consistent with NUREG-1801 item for material, environment, and aging effect. AMP takes some exceptions to NUREG-1801 AMP.

E Consistent with NUREG-1801 for material, environment, and aging effect, but a different aging management program is credited or NUREG-1801 identifies a plant-specific aging management program.

Section 3.3 AGING MANAGEMENT OF AUXILIARY SYSTEMS Callaway Plant Unit 1 License Renewal Application Plant Specific Notes:

1 The subject component is enclosed within another component. Loss of material on the external surface of the subject component is managed by the Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components program (B2.1.23).

2 Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components program (B2.1.23) is used instead of the Open-Cycle Cooling Water program since these components are nonsafety-related drains.

3 Component is refrigeration piping which is expected to experience condensation during times of elevated humidity on the external surface.

4 Fire Protection (B2.1.13) manages the aging effects associated with this fire damper material and environment combination.

Section 3.3 AGING MANAGEMENT OF AUXILIARY SYSTEMS Callaway Plant Unit 1 License Renewal Application Callaway Plant License Renewal Application Amendment 1 Revised Aging Management Program and Notes for the internal environment of Dampers; no new lines were added. New Plant Note added.

Table 3.3.2-13, Auxiliary Building HVAC System, (Page 3.3-164) is revised as follows (deleted text shown in strikethrough and new text underlined):

Table 3.3.2-13 Auxiliary Systems - Summary of Aging Management Evaluation - Auxiliary Building HVAC System Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Program NUREG-1801 Item Table 1 Item Notes Damper FB, PB Carbon Steel (Galvanized)

Ventilation Atmosphere (Int)

Loss of material Fire Protection (B2.1.13)

Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components (B2.1.23)

VII.F2.A-08 3.3.1.090 BE, 5

Section 3.3 AGING MANAGEMENT OF AUXILIARY SYSTEMS Callaway Plant Unit 1 License Renewal Application Notes for Table 3.3.2-13:

Standard Notes:

A Consistent with NUREG-1801 item for component, material, environment, and aging effect. AMP is consistent with NUREG-1801 AMP.

B Consistent with NUREG-1801 item for component, material, environment, and aging effect. AMP takes some exceptions to NUREG-1801 AMP.

C Component is different, but consistent with NUREG-1801 item for material, environment, and aging effect. AMP is consistent with NUREG-1801 AMP.

D Component is different, but consistent with NUREG-1801 item for material, environment, and aging effect. AMP takes some exceptions to NUREG-1801 AMP.

E Consistent with NUREG-1801 for material, environment, and aging effect, but a different aging management program is credited or NUREG-1801 identifies a plant-specific aging management program.

Plant Specific Notes:

1 The subject component is enclosed within another component. Loss of material on the external surface of the subject component will be managed by the Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components program (B2.1.23).

2 Ventilation air internal is a condensation environment and therefore is used interchangeably as the condensation - external environment.

3 Component internal environment is condensation from cooling coil drains that is evaluated as waste water per NUREG-1801,Section IX.

This waste water environment is managed by Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components program (B2.1.23) and not by Open-Cycle Cooling Water program (B2.1.10).

4 For discussion of concrete attributes and operating experience, see further evaluation in Section 3.5.2.2.2.1.4.

5 Fire Protection (B2.1.13) manages the aging effects associated with this fire damper material and environment combination.

Section 3.3 AGING MANAGEMENT OF AUXILIARY SYSTEMS Callaway Plant Unit 1 License Renewal Application Callaway Plant License Renewal Application Amendment 1 Revised Aging Management Program and Notes for the internal environment of Dampers; no new lines were added. New Plant Note added.

Table 3.3.2-14, Fuel Building HVAC System, (Page 3.3-173) is revised as follows (deleted text shown in strikethrough and new text underlined):

Table 3.3.2-14 Auxiliary Systems - Summary of Aging Management Evaluation - Fuel Building HVAC System Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Program NUREG-1801 Item Table 1 Item Notes Damper FB, PB Carbon Steel (Galvanized)

Ventilation Atmosphere (Int)

Loss of material Fire Protection (B2.1.13)

Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components (B2.1.23)

VII.F2.A-08 3.3.1.090 BE, 3 Notes for Table 3.3.2-14:

Standard Notes:

A Consistent with NUREG-1801 item for component, material, environment, and aging effect. AMP is consistent with NUREG-1801 AMP.

B Consistent with NUREG-1801 item for component, material, environment, and aging effect. AMP takes some exceptions to NUREG-1801 AMP.

C Component is different, but consistent with NUREG-1801 item for material, environment, and aging effect. AMP is consistent with NUREG-1801 AMP.

D Component is different, but consistent with NUREG-1801 item for material, environment, and aging effect. AMP takes some exceptions to NUREG-1801 AMP.

E Consistent with NUREG-1801 for material, environment, and aging effect, but a different aging management program is credited or NUREG-1801 identifies a plant-specific aging management program.

Section 3.3 AGING MANAGEMENT OF AUXILIARY SYSTEMS Callaway Plant Unit 1 License Renewal Application Plant Specific Notes:

1 The subject component is enclosed within another component. Loss of material on the external surface of the subject component is managed by the Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components program (B2.1.23).

2 Ventilation air internal is a condensation environment and therefore is used interchangeably as the condensation -external environment.

3 Fire Protection (B2.1.13) manages the aging effects associated with this fire damper material and environment combination.

Section 3.3 AGING MANAGEMENT OF AUXILIARY SYSTEMS Callaway Plant Unit 1 License Renewal Application Callaway Plant License Renewal Application Amendment 1 Revised to add Fire Barrier intended function to component type Damper. New Plant Note added.

Table 3.3.2-15, Miscellaneous Buildings HVAC System, (Page 3.3-183) is revised as follows (deleted text shown in strikethrough and new text underlined):

Table 3.3.2-15 Auxiliary Systems - Summary of Aging Management Evaluation - Miscellaneous Buildings HVAC System Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Program NUREG-1801 Item Table 1 Item Notes Damper FB, PB Carbon Steel (Galvanized)

Plant Indoor Air (Ext)

None None VII.J.AP-13 3.3.1.116 C

Damper FB Carbon Steel (Galvanized)

Ventilation Atmosphere (Int)

Loss of material Fire Protection (B2.1.13)

VII.F2.A-08 3.3.1.090 E, 2 Notes for Table 3.3.2-15:

Plant Specific Notes:

1 The subject component is enclosed within another component. Loss of material on the external surface of the subject component is managed by the Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components program (B2.1.23).

2 Fire Protection (B2.1.13) manages the aging effects associated with this fire damper material and environment combination.

Section 3.3 AGING MANAGEMENT OF AUXILIARY SYSTEMS Callaway Plant Unit 1 License Renewal Application Callaway Plant License Renewal Application Amendment 1 Revised Aging Management Program and Notes for the internal environment of Dampers; no new lines were added. New Plant Note added.

Table 3.3.2-17, Radwaste Building HVAC System, (Page 3.3-193) is revised as follows (deleted text shown in strikethrough and new text underlined):

Table 3.3.2-17 Auxiliary Systems - Summary of Aging Management Evaluation - Radwaste Building HVAC System Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Program NUREG-1801 Item Table 1 Item Notes Damper FB Carbon Steel (Galvanized)

Ventilation Atmosphere (Int)

Loss of material Fire Protection (B2.1.13)

Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components (B2.1.23)

VII.F2.A-08 3.3.1.090 BE, 2 Notes for Table 3.3.2-17:

Standard Notes:

A Consistent with NUREG-1801 item for component, material, environment, and aging effect. AMP is consistent with NUREG-1801 AMP.

B Consistent with NUREG-1801 item for component, material, environment, and aging effect. AMP takes some exceptions to NUREG-1801 AMP.

C Component is different, but consistent with NUREG-1801 item for material, environment, and aging effect. AMP is consistent with NUREG-1801 AMP.

D Component is different, but consistent with NUREG-1801 item for material, environment, and aging effect. AMP takes some exceptions to NUREG-1801 AMP.

E Consistent with NUREG-1801 for material, environment, and aging effect, but a different aging management program is credited or NUREG-1801 identifies a plant-specific aging management program.

Section 3.3 AGING MANAGEMENT OF AUXILIARY SYSTEMS Callaway Plant Unit 1 License Renewal Application Plant Specific Notes:

1 The subject component is enclosed within another component. Loss of material on the external surface of the subject component is managed by the Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components program (B2.1.23).

2 Fire Protection (B2.1.13) manages the aging effects associated with this fire damper material and environment combination.

Section 3.3 AGING MANAGEMENT OF AUXILIARY SYSTEMS Callaway Plant Unit 1 License Renewal Application Callaway Plant License Renewal Application Amendment 1 Revised Aging Management Program and Notes for the internal environment of Dampers; no new lines were added. New Plant Note added.

Table 3.3.2-18, Turbine Building HVAC System, (Page 3.3-195) is revised as follows (deleted text shown in strikethrough and new text underlined):

Table 3.3.2-18 Auxiliary Systems - Summary of Aging Management Evaluation - Turbine Building HVAC System Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Program NUREG-1801 Item Table 1 Item Notes Damper FB, PB Carbon Steel (Galvanized)

Ventilation Atmosphere (Int)

Loss of material Fire Protection (B2.1.13)

Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components (B2.1.23)

VII.F2.A-08 3.3.1.090 BE, 3 Notes for Table 3.3.2-18:

Standard Notes:

A Consistent with NUREG-1801 item for component, material, environment, and aging effect. AMP is consistent with NUREG-1801 AMP.

B Consistent with NUREG-1801 item for component, material, environment, and aging effect. AMP takes some exceptions to NUREG-1801 AMP.

C Component is different, but consistent with NUREG-1801 item for material, environment, and aging effect. AMP is consistent with NUREG-1801 AMP.

D Component is different, but consistent with NUREG-1801 item for material, environment, and aging effect. AMP takes some exceptions to NUREG-1801 AMP.

E Consistent with NUREG-1801 for material, environment, and aging effect, but a different aging management program is credited or NUREG-1801 identifies a plant-specific aging management program.

Plant Specific Notes:

Section 3.3 AGING MANAGEMENT OF AUXILIARY SYSTEMS Callaway Plant Unit 1 License Renewal Application 1

The subject component is enclosed within another component. Loss of material on the external surface of the subject component is managed by the Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components program (B2.1.23).

2 Ventilation air internal is a condensation environment and therefore is used interchangeably as the condensation -external environment.

3 Fire Protection (B2.1.13) manages the aging effects associated with this fire damper material and environment combination.

Appendix A Final Safety Analysis Report Supplement Callaway Plant Unit 1 Page A-2 License Renewal Application Amendment 1 A1.2 WATER CHEMISTRY The Water Chemistry program manages loss of material, cracking, reduction of heat transfer, and wall thinning in components exposed to a treated water environment. The Water Chemistry program is used to control water chemistry for impurities that accelerate corrosion. The program is a mitigation program that relies on monitoring and control of primary and secondary water chemistry to keep peak levels of various contaminants below system-specific limits based on EPRI guidelines. The Water Chemistry program is based on EPRI primary and secondary water chemistry guidelines. 1014986, PWR Primary Water Chemistry Guidelines, Revision 6 and EPRI 1016555, PWR Secondary Water Chemistry Guidelines, Revision 7.

The One-Time Inspection program (A1.18) verifies the effectiveness of the Water Chemistry program.

Appendix A Final Safety Analysis Report Supplement Callaway Plant Unit 1 Page A-4 License Renewal Application Amendment 1 A1.6 PWR VESSEL INTERNALS The PWR Vessel Internals program relies on implementation of the guidance included in Electric Power Research Institute (EPRI) 10165961022863 (MRP-227MRP-227-A),

PWR Internals Inspection and Evaluation Guideline and EPRI 1016609 (MRP-228),

Inspection Standard for PWR Internals (MRP-228) to manage the aging effects of reactor vessel internal (RVI) components.

This program is used to manage (a) various forms of cracking, including stress corrosion cracking (SCC), primary water stress corrosion cracking (PWSCC), irradiation assisted stress corrosion cracking (IASCC), or cracking due to fatigue/cyclical loading; (b) loss of material induced by wear; (c) loss of fracture toughness due to either thermal aging or neutron irradiation embrittlement; (d) changes in dimension due to void swelling and irradiation growth; and (e) loss of preload due to thermal and irradiation-enhanced stress relaxation or creep.

The PWR Vessel Internals program is a new program and will be implemented within 24 months after the issuance of MRP-227-A, PWR Internals Inspection and Evaluation Guideline.

Industry and plant-specific operating experience will be evaluated in the development and implementation of this program.

Appendix A Final Safety Analysis Report Supplement Callaway Plant Unit 1 Page A-4 License Renewal Application Amendment 1 A1.8 BOLTING INTEGRITY The Bolting Integrity program manages cracking, loss of material and loss of preload for pressure retaining bolting. The program includes periodic inspection of closure bolting for pressure-retaining components consistent with recommendations as delineated in NUREG-1339, Resolution of Generic Safety Issue 29: Bolting Degradation or Failure in Nuclear Power Plants and EPRI NP-5769, Degradation and Failure of Bolting in Nuclear Power Plants, Volume 1 and 2 with the exceptions noted in NUREG-1339. The Bolting Integrity program also includes activities for preload control, material selection and control, and use of lubricants/sealants as delineated in EPRI NPTR-104213, Bolted Joint Maintenance and Application Guide.

The ASME Section XI Inservice Inspection, Subsections IWB, IWC and IWD program supplements the Bolting Integrity program by providing the requirements for inservice inspection of ASME Class 1, 2, and 3 safety-related pressure retaining bolting. The integrity of non-ASME Class 1, 2, 3 system and component bolted joints is evaluated by detection of visible leakage during maintenance or routine observation such as system walkdowns.

Safety-related and nonsafety-related structural bolting is managed by the following programs:

(a) ASME Section XI, Subsection IWE program (A1.26) provides the requirements for inspection of structural bolting.

(b) ASME Section XI, Subsection IWF program (A1.28) provides the requirements for inservice inspection of safety-related component support bolting.

(c) Structures Monitoring program (A1.31) monitors the condition of structures and structural supports that are within the scope of license renewal.

(d) RG 1.127, Inspection of Water-Control Structures Associated with Nuclear Power Plants program (A1.32) provides the requirements for inspection of water control structures associated with emergency cooling water systems.

(e) Inspection of Overhead Heavy Load and Light Load (Related to Refueling) Handling Systems program (A1.12) provides the requirements for inspection of handling systems within the scope of license renewal.

Reactor pressure vessel head closure studs are managed by the Reactor Head Closure Stud Bolting program (A1.3).

Appendix A Final Safety Analysis Report Supplement Callaway Plant Unit 1 Page A-8 License Renewal Application Amendment 1 A1.14 FIRE WATER SYSTEM The Fire Water System program manages loss of material for water-based fire protection systems. Consistent with National Fire Protection Association commitments, the program consists of periodic full-flow flush tests, system performance tests to prevent corrosion from biofouling in the fire protection system, and testing or replacement of sprinklers that have been in place for 50 years. The fire protection system is normally maintained at required operating pressure and is monitored such that loss of system pressure is immediately detected and corrective actions initiated.

The Fire Water System program conducts flow tests through each open head spray/sprinkler nozzle to verify water flow is unobstructed. Non-intrusive Wall wall thickness evaluations examinations are performed on fire protection water piping to identify loss of material. As an alternative, visual internal inspections are used when the internal surface of the piping is exposed during plant maintenance. These inspections evaluate (a) wall thickness to ensure against catastrophic failure and (b) the inner diameter of the piping as it applies to the design flow of the fire protection system.

Appendix A Final Safety Analysis Report Supplement Callaway Plant Unit 1 Page A-8 License Renewal Application Amendment 1 A1.15 ABOVEGROUND METALLIC TANKS The Aboveground Metallic Tanks program manages loss of material and cracking on the external surfaces of aboveground metallic tanks within the scope of license renewal that are supported on concrete or soil. The program also manages cracking, blistering, and change in color of the acrylic/urethane insulation on the condensate storage tank. The program applies to the condensate storage tank, refueling water storage tank, and the two fire water storage tanks.

For the carbon steel fire water storage tanks, the program relies on application of paint, coating, or tank bottom edge grout as corrosion preventive measures.

This program performs visual inspections to monitor for aging of the tank external surface paint or damage of the insulation covering. Removal of the tank insulation is on an opportunistic basis to permit inspection of the tank external surface for aging.

Insulated tank exterior surfaces that have not been opportunistically inspected will be examined with thickness measurements from the internal surface, to determine the tank wall thickness.

Thickness measurements are taken from inside the emptied tanks to determine the thickness of the tank bottom, or insulated tank exterior surfaces that have not had an opportunistic inspection. The thickness measurements ensure significant loss of material is not occurring, so that the intended function of each tank is maintained during the period of extended operation.

The Aboveground Metallic Tanks program is a new program that will be implemented prior to the period of extended operation.

Industry and plant-specific operating experience will be evaluated in the development and implementation of this program.

Appendix A Final Safety Analysis Report Supplement Callaway Plant Unit 1 Page A-18 License Renewal Application Amendment 1 A1.35 INSULATION MATERIAL FOR ELECTRICAL CABLES AND CONNECTIONS NOT SUBJECT TO 10 CFR 50.49 ENVIRONMENTAL QUALIFICATION REQUIREMENTS USED IN INSTRUMENTATION CIRCUITS The Insulation Material for Electrical Cables and Connections Not Subject to 10 CFR 50.49 Environmental Qualification Requirements Used in Instrumentation Circuits program manages reduced insulation resistance to ensure that cables and connections used in sensitive instrumentation circuits with high voltage low-level current signals within the ex-core neutron monitoring system are capable of performing their intended functions. All high voltage cable to radiation monitors within the scope of license renewal are managed by the Environmental Qualification (EQ) of Electric Components program (A2.2).

This program provides reasonable assurance that the intended function of cables and connections used in instrumentation circuits with sensitive, low-level current signals that are not subject to the environmental qualification requirements of 10 CFR 50.49 and are exposed to adverse localized environments caused by temperature, radiation, or moisture are maintained consistent with the current licensing basis through the period of extended operation. In most areas, the actual ambient environments (e.g., temperature, radiation, or moisture) are less severe than the plant design environment for those areas.

Calibration or surveillance testsSurveillances are used to manage the aging of the cable insulation and connections for ex-core neutron monitors so that instrumentation circuits perform their intended functions. When an instrumentation channel is found to be out of calibration during routine calibration or surveillance testingsurveillances, troubleshooting is performed on the loop, including the instrumentation cable and connections. A review of calibrationsurveillance results will be completed prior to the period of extended operation and every 10 years thereafter.

Appendix A Final Safety Analysis Report Supplement Callaway Plant Unit 1 Page A-18 License Renewal Application Amendment 1 A1.36 INACCESSIBLE POWER CABLES NOT SUBJECT TO 10 CFR 50.49 ENVIRONMENTAL QUALIFICATION REQUIREMENTS The Inaccessible Power Cables Not Subject to 10 CFR 50.49 Environmental Qualification Requirements program manages reduced insulation resistance leading to electrical failure of in-scope non-EQ inaccessible power cables exposed to wetting or submergence caused by significant moisture. Significant moisture is defined as periodic exposures to moisture that last more than a few days.

Manholes, pits, and the ends of duct banks that contain in-scope non-EQ inaccessible power cables will be inspected for water collection andto confirm that cables are not submerged or immersed in water, cables/splices and cable support structures are intact, and dewatering/drainage systems (i.e., sump pumps) and associated alarms operate properly. Collected water will be removed as required. This inspection and water removal will be performed based on actual plant experience with inspection frequency being at least annually and after event driven occurrences (such as heavy rain or flooding). Dewatering devices will be inspected and operation verified prior to any known or predicted heavy rain or flooding events. The first inspection for license renewal is to be completed prior to the period of extended operation.

All inIn-scope non-EQ inaccessible power cables routed through manholes, pits, and duct banks are tested to provide an indication of the conductor insulation condition.

Testing that is appropriate to the application at the time of the testing will be performed to detect deterioration of the insulation system due to wetting. Cable testing may be a mix of proven testing methods (such as dielectric loss [dissipation factor/power factor],

AC voltage withstand, partial discharge, step voltage, low frequency dissipation factor, time domain reflectometry, insulation resistance and polarization index, or line resonance analysis) that are state-of-the-art at the time of testing. The first test for license renewal will be completed prior to the period of extended operation and every 6 years thereafter.

Appendix A Final Safety Analysis Report Supplement Callaway Plant Unit 1 Page A-20 License Renewal Application Amendment 1 A1.39 METAL ENCLOSED BUS The Metal Enclosed Bus program manages aging of in-scope non-segregated phase metal enclosed bus buses including bus, and connections, enclosures, and insulation and insulators. The internal surfaces of bus enclosure assemblies are inspected for cracks, corrosion, foreign debris, excessive dust buildup, and evidence of water moisture intrusion. Bus insulation is inspected for signs of reduced insulation resistance due to thermal/thermoxidative degradation of organics/thermoplastics, radiation-induced oxidation, moisture/debris intrusion, or ohmic heating, as indicated by embrittlement, cracking, chipping, melting, discoloration, or swelling, which may indicate overheating or aging degradation. The internal bus insulating supports are inspected for structural integrity and signs of cracks. The external portions of the MEB a bus, including gaskets and sealants, are inspected for surface cracking, crazing, scuffing, dimensional change (e.g., ballooning and necking), shrinkage, discoloration, hardening and loss of strength due to elastomer degradation. The external surfaces are inspected for loss of material due to general, pitting, and crevice corrosion. A sample of the accessible bolted connections will be inspected for increased resistance of connection due to loosening of bolts using thermography or by measuring connection resistance. For accessible bolted connections that are covered with heat shrink tape, sleeving, insulating boots, etc.,by a visual inspection of insulating material will be conducted.

The first inspection of the metal enclosed bus buses, including a sample of bolted connections, will be completed prior to the period of extended operation and every 10five years thereafter. Where visual inspection of insulating material is conducted, the inspection interval of bolted connections will be every five years thereafter.

Industry and plant-specific operating experience will be evaluated in the development and implementation of this program.

Appendix A Final Safety Analysis Report Supplement Callaway Plant Unit 1 License Renewal Application Amendment 1 Table A4-1 License Renewal Commitments Item #

Commitment LRA Section Implementation Schedule 5

Enhance the Bolting Integrity program procedures to:

reference NUREG-1339 and EPRI NP-5769 to meet the NUREG-1801 recommendations (Completed LRA Amendment 1) include bolting in the list of items to be inspected during walkdowns.

B2.1.8 Prior to the period of extended operation 9

Enhance the Fire Protection program procedures to:

include visual inspections of the external surfaces of Halon fire suppression system components for excessive loss of material due to corrosion.

include trending of the performance of the Halon system during testing. (Completed LRA Amendment 1)

B2.1.13 Prior to the period of extended operation 10 Enhance the Fire Water System program procedures to:

include non-intrusive pipe wall thickness examinations on fire water piping. As an alternative to wall thickness examinations, internal inspections will be performed on accessible exposed portions of fire water piping during plant maintenance activities.

Pipe wall thickness examinations and/or internal inspections will be performed prior to the period of extended operation and at 10-year frequencies throughout the period of extended operation.

replace sprinkler heads prior to 50 years in service or test a representative sample and test every 10 years thereafter to ensure signs of degradation are detected in a timely manner.

review and evaluate trends in flow parameters recorded during the NFPA 25 fire water flow tests B2.1.14 Prior to the period of extended operation 26 Enhance the Insulation Material for Electrical Cables and Connections Not Subject to 10 CFR 50.49 Environmental Qualification Requirements Used in Instrumentation Circuits program procedures to:

identify the scope of cables requiring aging management.

require engineering review of calibrationsurveillance results every 10 years B2.1.35 Prior to the period of extended operation

Appendix A Final Safety Analysis Report Supplement Callaway Plant Unit 1 License Renewal Application Amendment 1 Table A4-1 License Renewal Commitments Item #

Commitment LRA Section Implementation Schedule Initiate corrective actions when surveillance results do not meet acceptance criteria, and to require an engineering evaluation be performed. When an unacceptable condition or situation is identified, a determination is also made as to whether the review of surveillance results or the cable testing frequency needs to be increased.

27 Enhance the Inaccessible Power Cables Not Subject to 10 CFR 50.49 Environmental Qualification Requirements program procedures to:

identify the power cables, manholes, pits and duct banks that are within the scope of the Inaccessible Power Cables Not Subject to 10 CFR 50.49 Environmental Qualification Requirements program.

include periodic inspection of manholes, pits and duct banks, to ensure powerconfirm cables are not submerged or immersed in water, cables/splices and support structures are not submerged or immersed in water, and to ensure that cable support structures are intact, and dewatering/drainage systems (i.e, sump pumps) and associated alarms operate properly.

Identify that inspections will be performed at least annually based on water accumulation over time and after event driven occurrences (e.g., heavy rain or flooding).

In addition, operation of dewatering devices will be inspected and operation verified prior to any known or predicted heavy rain or flooding events. Power cables subject to significant moisture are tested periodically.

ensure in-scope power cables are tested at least once every six years.

compare test results to previous test results to evaluate for additional information on the rate of cable degradation.

Ensureconfirm cables are not submerged or immersed in water, cables/splices and cable support structures are not submerged or immersed in standing waterintact, and dewatering/drainage systems (i.e., sump pumps) and associated alarms operate properly. Acceptance criteria for cable testing will be defined prior to each test.

require an engineering evaluation when the test or inspection acceptance criteria are not met.

B2.1.36 Prior to the period of extended operation

Appendix B AGING MANAGEMENT PROGRAMS Callaway Plant Unit 1 Page B-25 License Renewal Application Amendment 1 B2.1.5 Cracking of Nickel-Alloy Components and Loss of Material Due to Boric Acid-Induced Corrosion in Reactor Coolant Pressure Boundary Components Program Description The Cracking of Nickel-Alloy Components and Loss of Material Due to Boric Acid-Induced Corrosion in Reactor Coolant Pressure Boundary Components program manages cracking of nickel-alloy components and associated welds as well as loss of material due to boric acid-induced corrosion in susceptible components in the vicinity of nickel-alloy reactor coolant pressure boundary components.

Detection of aging is accomplished through examinations consistent with ASME Section XI Subsection IWB Code Case N-722-1, subject to the conditions listed in 10 CFR 50.55a(g)(6)(ii)(E), Code Case N-729-1, subject to the conditions specified in 10 CFR 50.55a(g)(6)(ii)(D), and Code Case N-770-1, subject to the conditions listed in 10 CFR 50.55a(g)(6)(ii)(F).

Code Case N-729-1 establishes the examination requirements and acceptance standards for the reactor pressure vessel (RPV) upper head and its penetration nozzles. Code Case N-722-1 establishes examination requirements and acceptance standards for nickel-alloy reactor coolant pressure boundary welds in RPV bottom-mounted instrument penetrations, RPV nozzles, pressurizer penetrations/nozzles, reactor coolant system instrument connections, and steam generator primary side components. Code Case N-770-1 establishes examination requirements and acceptance standards for Class 1 butt weld locations requiring inspections.

This program provides for bare-metal visual, surface, and volumetric examinations of nickel-alloy components, and components whose leakage may affect the reactor vessel head, for pressure boundary leakage and signs of boric acid leakage on adjacent ferritic steel components. Repair and replacement activities are performed to remove or overlay nickel-alloy material or as a corrective action in response to an unacceptable flaw.

The impacts of all boric acid leakage from non-nickel-alloy reactor coolant pressure boundary components, provisions for identifying and evaluating leakage, and initiating corrective actions for boric acid leakage are managed by the Boric Acid Corrosion program (B2.1.4).

The Water Chemistry program (B2.1.2) monitors and controls water environments in accordance with industry guidelines; thereby ensuring water environments are favorable for mitigation of primary water stress corrosion cracking (PWSCC) and related mechanisms in nickel-alloy components.

NUREG-1801 Consistency The Cracking of Nickel-Alloy Components and Loss of Material Due to Boric Acid-Induced Corrosion in Reactor Coolant Pressure Boundary Components program is an existing program that is consistent with NUREG-1801,Section XI.M11B, Cracking of Nickel-Alloy

Appendix B AGING MANAGEMENT PROGRAMS Callaway Plant Unit 1 Page B-26 License Renewal Application Amendment 1 Components and Loss of Material Due to Boric Acid-Induced Corrosion in Reactor Coolant Pressure Boundary Components.

Exceptions to NUREG-1801 None Enhancements None Operating Experience The following discussion of operating experience provides objective evidence that the Cracking of Nickel-Alloy Components and Loss of Material Due to Boric Acid-Induced Corrosion in Reactor Coolant Pressure Boundary Components program will be effective in ensuring that intended functions are maintained consistent with the current licensing basis for the period of extended operation:

1. During Refuel 14 (Fall 2005), the steam generators were replaced. The only location of alloy-600 type material in the replacement steam generators is the Alloy 182 tubesheet cladding, which is not under tensile loads, and therefore is not considered susceptible to PWSCC. The tube sheet cladding is under extremely low tensile loads, and therefore is considered to have an extremely low susceptibility to PWSCC.
2. During Refuel 15 (Spring 2007), the RPV head penetrations were examined using volumetric and surface techniques. No evidence of cracking or leak path was identified with the volumetric and surface examinations. No evidence of leakage from the penetration nozzles or indications of wastage was identified during bare metal visual examinations. An indication was visually detected in the RPV lower head cladding in 2007, during the remote VT-3 examination of the vessel interior. The indication was evaluated and additional volumetric and surface examinations were performed for better characterization. The indication was determined to be acceptable as is. During Refuel 17 (Spring 2010), a VT-2 exam of the RPV head and penetration nozzles identified indications of leakage on the control rod drive mechanism housings. No indications of leakage were found on the carbon steel RPV head. An evaluation determined the stains are from a prior vent line valve leak from above the RPV head insulation. Leaking reactor coolant had dripped down on the stainless steel control rod drive mechanism housings and was determined not to be a significant issue.
3. During Refuel 15 (Spring 2007), the Callaway RPV hot leg and cold leg nozzles were volumetrically examined. No evidence of cracking or leak path was identified in the nozzle to pipe dissimilar metal welds. During Refuel 17 (Spring 2010), the Callaway RPV hot-leg and cold-leg nozzle to pipe welds were examined visually. No evidence of leakage from any of the eight nozzle welds was identified.

Appendix B AGING MANAGEMENT PROGRAMS Callaway Plant Unit 1 Page B-27 License Renewal Application Amendment 1

4. During Refuel 15 (Spring 2007), a full structural weld overlay using Alloy 52M was performed on six pressurizer nozzles, including the surge nozzle, spray nozzle, and the four safety and relief nozzles. The overlays mitigate Alloy 82/182 safe-end welds with application of the PWSCC highly resistant Alloy 52M weld overlay. Before the overlays were applied, no crack-like indications were identified in the pressurizer nozzle dissimilar metal welds. During Refuel 16 (Fall 2008), UT examination of the pressurizer weld overlays were performed, the welds of each weld overlay were examined, and no recordable indications were identified
5. During Refuel 17(Spring 2010), the 12 hot-leg thermowells and the four cold-leg thermowells were visually examined. No evidence of leakage was indentified.
6. During Refuel 17 (Spring 2010), the 58 Callaway RPV bottom-mounted instrumentation nozzle penetrations and the dissimilar metal welds were visually examined. No evidence of leakage from the nozzle penetrations and dissimilar metal welds was identified.

Examination methods implemented by the Cracking of Nickel-Alloy Components and Loss of Material Due to Boric Acid-Induced Corrosion in Reactor Coolant Pressure Boundary Components program have been effective in detection of cracking and loss of material.

Occurrences that would be identified under the Cracking of Nickel-Alloy Components and Loss of Material Due to Boric Acid-Induced Corrosion in Reactor Coolant Pressure Boundary Components program will be evaluated to assure there is no significant impact to safe operation of the plant and corrective actions will be taken to prevent recurrence.

Guidance for re-evaluation, repair, or replacement is provided for locations where aging is found. There is confidence that the continued implementation of the Cracking of Nickel-Alloy Components and Loss of Material Due to Boric Acid-Induced Corrosion in Reactor Coolant Pressure Boundary Components program will effectively identify aging prior to loss of intended function.

Conclusion The continued implementation of the Cracking of Nickel-Alloy Components and Loss of Material Due to Boric Acid-Induced Corrosion in Reactor Coolant Pressure Boundary Components program provides reasonable assurance that aging effects will be managed such that the systems and components within the scope of this program will continue to perform their intended functions consistent with the current licensing basis for the period of extended operation.

Appendix B AGING MANAGEMENT PROGRAMS Callaway Plant Unit 1 Page B-28 License Renewal Application Amendment 1 B2.1.6 PWR Vessel Internals Program Description The PWR Vessel Internals program manages cracking, loss of material, loss of fracture toughness, change in dimension, and loss of preload for reactor vessel internal components intended to provide core structural support. The program implements the guidance of EPRI 10165961022863 (MRP-227-A), PWR Internals Inspection and Evaluation Guideline (MRP-227, Revision 0) and EPRI 1016609 (MRP-228), Inspection Standard for PWR Internals (MRP-228, Revision 0). Applicable aging management program plant-specific action items, conditions and limitations identified in NRC Safety Evaluation for MRP-227 have been addressed in this aging management program.

The program is designed to identify cracking, loss of material induced by wear, loss of fracture toughness due to either thermal aging or neutron irradiation embrittlement, change in dimension due to void swelling and irradiation growth, distortion, or deflection, and loss of preload due to thermal and irradiation-enhanced stress relaxation or creep. The cracking mechanisms managed by this program include stress corrosion cracking (SCC), primary water stress corrosion cracking (PWSCC), irradiation-assisted stress corrosion cracking (IASCC), and cracking due to fatigue/cyclical loading.

The reactor vessel internal components are chosen for one of four inspection sample groups based on the guidance of MRP-227MRP-227-A. The primary group inspections manage aging consistent with the inspection guidance of Table 4-3 (Westinghouse components) of MRP-227MRP-227-A and are expected to show the leading indications of aging effects.

The expansion group inspections manage aging consistent with Table 4-6 (Westinghouse components) of MRP-227MRP-227-A after inspections find aging effects to be more severe than anticipated in the primary group inspections. Components in the existing program group inspections, consistent with the inspection guidance in Table 4-9 of MRP-227-A, are adequately managed by existing programs, such as ASME Code,Section XI, Examination Category B-N-3 examinations of core support structures. The fourth group consists of components for which aging effects were determined to be negligible, relative to other internals components, and no additional measures for aging management are specified.

Program examination methods include visual examination (VT-3), enhanced visual examination (EVT-1), volumetric examination, and physical measurements. Visual examinations are performed consistent with the guidance of MRP-227MRP-227-A. The MRP-227MRP-227-A guidance is consistent with the ASME Code Section XI rules, and includes additional guidance and methods of detecting relevant conditions. Volumetric examinations of reactor vessel internals, such as bolting, pins, and fasteners, are performed in accordance with the guidance of MRP-228 and MRP-227MRP-227-A. This guidance includes requirements for the ultrasonic testing techniques used to detect loss of integrity of reactor vessel internals bolts, pins and fasteners.

Integral attachments to the internal surface of the reactor vessel are managed by the ASME Section XI Inservice Inspection, Subsections IWB, IWC, and IWD program (B2.1.1)

Examination Category B-N-2. Bottom mounted instrumentation flux thimble tubes are managed by the Flux Thimble Tube Inspection program (B2.1.22).

Appendix B AGING MANAGEMENT PROGRAMS Callaway Plant Unit 1 Page B-29 License Renewal Application Amendment 1 The PWR Vessel Internals program is a new program that will be implemented within 24 months after the issuance of MRP-227-A, PWR Internals Inspection and Evaluation Guideline. The program will include future industry operating experience, as it is incorporated into future revisions of MRP-227MRP-227-A, to provide reasonable assurance for the long-term integrity of the reactor vessel internals.

NUREG-1801 Consistency The PWR Vessel Internals program is a new program that, when implemented, will be consistent with NUREG-1801,Section XI.M16A, PWR Vessel Internals.

Exceptions to NUREG-1801 None Enhancements None Operating Experience The following discussion of operating experience provides objective evidence that the PWR Vessel Internals program will be effective in ensuring that intended functions are maintained consistent with the current licensing basis for the period of extended operation:

1. Based on industry operating experience, Callaway replaced the Alloy-750 guide tube support pins (split pins) with strained hardened (cold worked) 316 stainless steel pins during Refuel 13 (Spring 2004) to reduce the susceptibility for stress corrosion cracking in the split pins. There were no cracked Alloy X-750 pins discovered during the replacement process.
2. The ASME Code,Section XI, Examination Category B-N-3 examinations of core support structures conducted during the Refuel 13 (Spring 2004), did not identify any conditions that required repair or replacement.
3. With exception of the existing program components managed by ASME Section XI ISI, the Callaway PWR Vessel Internals program will be a new program. A key element of the program defined in MRP-227MRP-227-A is the requirement to report aging effects of reactor vessel internal components. Callaway, through its participation in PWR Owners Group and EPRI-MRP activities, will continue to benefit from the industry-wide collaboration of results from internals inspections.

The operating experience of the ASME Code,Section XI, Examination Category B-N-3 examinations of core support structures did not identify any significant age-related deficiencies. Occurrences that would be identified under the PWR Vessel Internals program will be evaluated to ensure there is no significant impact to safe operation of the plant and corrective actions will be taken to prevent recurrence. Guidance for re-evaluation, repair, or replacement is provided for locations where aging is found. Therefore, there is confidence that implementation of the PWR Vessel Internals program will effectively identify aging prior to loss of intended function.

Appendix B AGING MANAGEMENT PROGRAMS Callaway Plant Unit 1 Page B-30 License Renewal Application Amendment 1 Industry and plant-specific operating experience will be evaluated in the development and implementation of this program.

Conclusion The implementation of the PWR Vessel Internals program will provide reasonable assurance that aging effects will be managed such that the systems and components within the scope of this program will continue to perform their intended functions consistent with the current licensing basis for the period of extended operation.

Appendix B AGING MANAGEMENT PROGRAMS Callaway Plant Unit 1 Page B-34 License Renewal Application Amendment 1 B2.1.8 Bolting Integrity Program Description The Bolting Integrity program manages cracking, loss of material and loss of preload for pressure retaining bolting. The program includes preload control, selection of bolting material, use of lubricants/sealants, and performance of periodic inspections for indication of aging effects.

The general practices that are established in this program are consistent with the recommendations, as delineated in NUREG-1339, Resolution of Generic Safety Issue 29:

Bolting Degradation or Failure in Nuclear Power Plants, and EPRI NP-5769, Degradation and Failure of Bolting in Nuclear Power Plants, Volume 1 and 2 with the exception noted in NUREG-1339 for safety-related bolting. In addition to the inspection activities noted above, the Bolting Integrity program includes activities for preload control, material selection and control, and use of lubricants/sealants as delineated in EPRI TR-104213, Bolted Joint Maintenance and Applications Guide.

ASME Section XI Inservice Inspection, Subsections IWB, IWC and IWD program (B2.1.1) supplements the Bolting Integrity program to manage cracking, loss of preload, and loss of material by providing the requirements for inservice inspection of ASME Class 1, 2, and 3 safety-related pressure retaining bolting. Examinations are currently performed in accordance with the ASME Section XI, 1998 Edition with the 2000 Addenda, per the ISI program plan. As required by 10 CFR 50.55a(g)(4)(ii), the Callaway ISI Program is updated during each successive 120-month inspection interval to comply with the requirements of the latest edition of the Code specified twelve months before the start of the inspection interval. Callaway will use the ASME Code Edition consistent with the provisions of 10 CFR 50.55a during the period of extended operation. The extent and schedule of the inspections is in accordance with IWB-2500-1, IWC-2500-1 and IWD-2500-1 and assures that detection of leakage or fastener degradation occurs prior to loss of system or component intended functions. Bolting associated with Class 1 vessel, valve and pump flanged joints receive visual (VT-1) inspection. For other pressure retaining bolting, routine observations identify any leakage before the leakage becomes excessive.

Inspection activities for bolting in a submerged environment are performed in conjunction with associated component maintenance activities. Inspection activities for bolting in buried and underground applications is performed in conjunction with inspection activities for the Buried and Underground Piping and Tanks (B2.1.25) program due to the restricted accessibility to these locations.

The integrity of non-ASME Class 1, 2, 3 system and component bolted joints is evaluated by detection of visible leakage during maintenance or routine observation such as system walkdowns. Inspection activities for non-ASME Class 1, 2, or 3 bolting in a submerged environment are performed in conjunction with associated component maintenance activities.

Appendix B AGING MANAGEMENT PROGRAMS Callaway Plant Unit 1 Page B-35 License Renewal Application Amendment 1 The Corrective Action Program is used to document and manage those locations where leakage was identified during routine observations including engineering walkdowns and equipment maintenance activities. Based on the severity of the leak and the potential to impact plant operations, nuclear or industrial safety, a leak may be repaired immediately, scheduled for repair, or monitored for change. If the leak rate changes (increases, decreases or stops), the monitoring frequency is re-evaluated and may be revised.

High strength bolts (actual yield strength 150 ksi) are not used on pressure retaining bolted joints within the scope of the Bolting Integrity program.

Procurement controls and installation practices, defined in plant procedures, include preventive measures to ensure that only approved lubricants, sealants, and proper torque are applied.

Safety-related and nonsafety-related structural bolting is managed by the following programs:

(a) ASME Section XI, Subsection IWE program (B2.1.26) provides the requirements for inspection of structural bolting.

(b) ASME Section XI, Subsection IWF program (B2.1.28) provides the requirements for inservice inspection of safety-related component support bolting.

(c) Structures Monitoring program (B2.1.31) monitors the condition of structures and structural supports that are within the scope of license renewal.

(d) RG 1.127, Inspection of Water-Control Structures Associated with Nuclear Power Plants program (B2.1.32) provides the requirements for inspection of water control structures associated with emergency cooling water systems.

(e) Inspection of Overhead Heavy Load and Light Load (Related to Refueling) Handling Systems program (B2.1.12) provides the requirements for inspection of handling systems within the scope of license renewal.

Reactor pressure vessel head closure studs are not included in the Bolting Integrity program. The Reactor Head Closure Stud Bolting program (B2.1.3) provides the requirements for inspection of the reactor vessel head closure studs.

NUREG-1801 Consistency The Bolting Integrity program is an existing program that, following enhancement, will be consistent with NUREG-1801,Section XI.M18, Bolting Integrity.

Exceptions to NUREG-1801 None

Appendix B AGING MANAGEMENT PROGRAMS Callaway Plant Unit 1 Page B-36 License Renewal Application Amendment 1 Enhancements Prior to the period of extended operation, the following enhancements will be implemented in the following program elements:

Scope of the Program (Element 1), Preventive Actions (Element 2,) Detection of Aging Effects (Element 4), and Corrective Action (Element 7)

Procedures will be enhanced to reference NUREG-1339 and EPRI NP-5769 to meet the NUREG-1801 recommendations.

Scope of the Program (Element 1), Parameters Monitored or Inspected (Element 3),and Detection of Aging Effects (Element 4)

Procedures will be enhanced to include bolting in the list of items to be inspected during walkdowns.

Operating Experience The following discussion of operating experience provides objective evidence that the Bolting Integrity program will be effective in ensuring that intended functions are maintained consistent with the current licensing basis for the period of extended operation.

1. The Bolting Integrity program incorporates the applicable industry experience on bolting issues into the program. Actions taken include confirmatory testing/analysis or inspections. Also included are the addition of procedures of inspection, material procurement and verification processes.
2. A review of plant operating experience identified issues with corrosion, missing or loose bolts, inadequate thread engagement, and improper bolt applications. Identified concerns were corrected or evaluated to be accepted as-is. No generic bolting failure issues or trends have been identified. There is no documented case of cracking of pressure containing retaining bolting due to stress corrosion cracking..

The operating experience of the Bolting Integrity program shows that the program effectively monitors and trends the aging effects of cracking, loss of material, and loss of preload on pressure retaining bolting and takes appropriate corrective action prior to loss of intended function. Occurrences that would be identified under the Bolting Integrity program will be evaluated to ensure there is no significant impact to safe operation of the plant and corrective actions will be taken to prevent recurrence. Guidance for re-evaluation, repair, or replacement is provided for locations where aging is found. There is confidence that the continued implementation of the Bolting Integrity program will effectively identify aging prior to loss of intended function.

Appendix B AGING MANAGEMENT PROGRAMS Callaway Plant Unit 1 Page B-37 License Renewal Application Amendment 1 Conclusion The continued implementation of the Bolting Integrity program, following enhancement, provides reasonable assurance that aging effects will be managed such that the systems and components within the scope of this program will continue to perform their intended functions consistent with the current licensing basis for the period of extended operation.

Appendix B AGING MANAGEMENT PROGRAMS Callaway Plant Unit 1 Page B-38 License Renewal Application Amendment 1 B2.1.9 Steam Generators Program Description The Steam Generators program manages cracking, loss of material, and wall thinning of the steam generators. This program is applicable to the steam generator tubes, plugs, sleeves, and secondary side steam generator internal components. Aging is managed through assessment of potential degradation mechanisms, inspections, tube integrity assessments, plugging and repairs, primary to secondary leakage monitoring, maintenance of secondary side component integrity, primary side and secondary side water chemistry, and foreign material exclusion. Callaway procedural guidance implements the performance criteria for tube integrity, condition monitoring requirements, inspection scope and frequency, acceptance criteria for the plugging or repair of flawed tubes, acceptable tube repair methods, leakage monitoring requirements, operational leakage and accident induced leakage requirements of Callaway technical specifications.

The program reporting criteria, inspection scope and frequency, assessments, plugging criteria, and primary to secondary leak rate monitoring, and monitoring/controlling primary and secondary side water chemistry are consistent with the requirements of Callaway technical specifications, the Maintenance Rule (10 CFR 50.65), EPRI 1019038, Steam Generator Integrity Assessment Guidelines, EPRI 1013706, PWR Steam Generator Examination Guidelines, EPRI 1008219, PWR Primary-to-Secondary Leak Guidelines, EPRI 1014983, Steam Generator In-Situ Pressure Test Guidelines, EPRI 1014986, PWR Primary Water Chemistry Guidelines, and EPRI 1016555, PWR Secondary Water Chemistry Guidelines. The EPRI guidelines provide a generic industry program to implement the NEI 97-06, Steam Generator Program Guidelines, Revision 3.

The Steam Generators program includes preventive measures to mitigate aging related to corrosion phenomena through foreign material exclusion as a means to inhibit wear degradation. The Callaway Water Chemistry program (B2.1.2) also monitors and controls reactor water chemistry and secondary water chemistry for the steam generators consistent with EPRI guidelines applicable to reactor water chemistry and secondary water chemistry as a preventive measure.

The Steam Generators program detects flaws in tubing, plugs, and tube supports needed to maintain tube integrity. Nondestructive examination (NDE) techniques are used to inspect all tubing materials to identify tubes that may need to be removed from service or repaired in accordance with plant technical specifications. The program provides criteria for the qualification of personnel, specific techniques, and the associated acquisition and analysis of data, including procedures, probe selection, analysis protocols, and reporting criteria. Assessment of tube integrity and plugging or repair criteria of flawed tubes is in accordance with plant technical specifications and the program implementing procedures. Tube structural integrity limits consistent with Regulatory Guide 1.121, Bases for Plugging Degraded PWR Steam Generator Tubes, are applied as detailed in Callaway Technical Specifications, Section 5.5.9. Plugs and

Appendix B AGING MANAGEMENT PROGRAMS Callaway Plant Unit 1 Page B-39 License Renewal Application Amendment 1 tube supports with aging are evaluated for corrective actions in accordance with the Callaway Corrective Action Program and the Callaway Steam Generators program.

Condition monitoring assessments are performed to determine whether structural and accident leakage criteria have been satisfied. Operational assessments are performed after inspections to verify that structural and leakage integrity will be maintained for the operating interval between inspections, which is selected in accordance with the technical specifications and NEI 97-06 guidelines. Comparison of the results of the condition monitoring assessment with the predictions of the previous operational assessment provides feedback for evaluation of the adequacy of the operational assessment and additional insights that can be incorporated into the next operational assessment.

The original Callaway steam generators were replaced in 2005. The replacement steam generators incorporate features designed to improve reliability and minimize aging.

Industry experience and laboratory testing have shown the materials used in fabricating the new steam generators to be more resistant to aging effects than those in the original steam generators.

NUREG-1801 Consistency The Steam Generators program is an existing program that is consistent with NUREG-1801,Section XI.M19, Steam Generators.

Exceptions to NUREG-1801 None Enhancements None Operating Experience The following discussion of operating experience provides objective evidence that the Steam Generators program will be effective in ensuring that intended functions are maintained consistent with the current licensing basis for the period of extended operation.

1. During Refuel 14 (Fall 2005), steam generators were replaced with AREVA designed steam generators with alloy 690 thermally treated tubes. Pre-service eddy current inspections found 77 small dings, four tubes with signals similar to outside diameter axial cracking, and 33 tubes with a spiral signal pattern. After analyzing the signals and the tubes containing indications, the tubes were found to have no detectable degradation. Two tubes wereOne tube was plugged due to manufacturing defects.

Visual inspections of the SG secondary side were performed to identify any foreign objects that may have been left behind after uprighting and installation of the steam generators. Several foreign objects were found during these inspections and removed prior to placing the steam generators in service.

Appendix B AGING MANAGEMENT PROGRAMS Callaway Plant Unit 1 Page B-40 License Renewal Application Amendment 1

2. During Refuel 15 (Spring 2007), the first in-service inspection of the new steam generators identified a total of 92 anti-vibration bar (AVB) wear indications, with the largest indication being a 14 percent through-wall flaw. As discussed in the Refuel 15 operational assessment, Callaway does not expect to exceed the structural integrity performance criteria for AVB wear prior to the next scheduled steam generator inspection in Refuel 18 (Fall 2011).
3. In the degradation assessment for Refuel 17 (Spring 2010), Callaway monitored other plants with AREVA RSGs, both domestically and internationally. Specifically, Doel 4, Tihange 3, Prairie Island 1, and Salem 2 have Westinghouse-style steam generators manufactured by AREVA in the same time period as the Callaway RSGs.

All four plants are experiencing various amounts of AVB wear in the same general location as Callaway.

4. Plant chemistry has been good and corrosion transport has been significantly reduced since the replacement of the main condenser in Refuel 13 (Spring 2004).

Sludge lancing for all four replacement steam generators was performed for the first time in Refuel 18 (Fall 2011).

The operating experience of the Steam Generators program did not show any adverse trend in inspection results. Occurrences that would be identified under the Steam Generator program will be evaluated to ensure there is no significant impact to the safe operation of the plant and adequate corrective actions will be taken to prevent recurrence. Appropriate guidance for re-evaluation, repair, or replacement will be provided for locations where aging is found. There is confidence that the continued implementation of the Steam Generators program will effectively identify aging prior to loss of intended function.

Conclusion The continued implementation of the Steam Generators program provides reasonable assurance that aging effects will be managed such that the systems and components within the scope of this program will continue to perform their intended functions consistent with the current licensing basis for the period of extended operation.

Appendix B AGING MANAGEMENT PROGRAMS Callaway Plant Unit 1 Page B-50 License Renewal Application Amendment 1 B2.1.13 Fire Protection Program Description The Fire Protection program manages loss of material of fire rated doors, fire dampers, and the Halon system, concrete cracking, spalling, and loss of material of fire barrier walls, ceilings, and floors, and increased hardness, shrinkage, and loss of strength of fire barrier penetration seals. The Fire Protection program is a condition and performance monitoring program comprised of tests and inspections that follow the applicable National Fire Protection Association (NFPA) recommendations.

The program requires visual inspections of not less than 10 percent of each type of penetration seal at least once per refueling cycle (18 months). The program specifies visual inspections of the fire barrier walls, ceilings and floors in structures within the scope of license renewal at a frequency of at least once per 18 months. Inspections of fire barriers include coatings and wraps. Periodic visual and functional tests are used to manage the aging effects of fire doors. The visual inspection frequency for fire doors is at least once per 18 months, and functional tests of closing mechanisms and latches for required doors is at least once per 18 months. Not less than 10 percent of the fire dampers are visually inspected at least once per 18 months.

Visual inspections of the Halon system will be performed to identify conditions of corrosion. A functional test of the Halon system is performed every 18 months, which is in accordance with Callaway's NRC-approved fire protection program (FSAR Table 9.5.1-2, Item 4 SP).

NUREG-1801 Consistency The Fire Protection program is an existing program that, following enhancement, will be consistent with NUREG-1801,Section XI.M26, Fire Protection.

Exceptions to NUREG-1801 None Enhancements Prior to the period of extended operation, the following enhancements will be implemented in the following program elements:

Parameters Monitored or Inspected (Element 3), Detection of Aging Effects (Element 4),

Monitoring and Trending (Element 5), and Acceptance Criteria (Element 6)

Procedures will be enhanced to include visual inspections of the external surfaces of Halon fire suppression system components for excessive loss of material due to corrosion.

Appendix B AGING MANAGEMENT PROGRAMS Callaway Plant Unit 1 Page B-51 License Renewal Application Amendment 1 Monitoring and Trending (Element 5)

Procedures will be enhanced to include trending of the performance of the Halon system during testing.

Operating Experience The following discussion of operating experience provides objective evidence that the Fire Protection program will be effective in ensuring that intended functions are maintained consistent with the current licensing basis for the period of extended operation.

1. Fire Barrier Penetration Seals In 2004, Callaway was notified by Wolf Creek of a concern with the seismic gap isolation seal between the auxiliary building and containment. At Callaway, 11 of the 23 seals were found to be incorrectly installed such that they did not meet a three-hour rated fire barrier. The deficient seals were repaired and a plant procedure was revised to clearly state the requirements for a three-hour rated fire barrier.

In 2009, a degraded fire barrier penetration seal was discovered, consisting of a void between the penetration seal and sleeve. The seal appeared to be loose from the sleeve, however, no leaks were identified and the seal was repaired.

2. Fire Doors Between 2002 and 2011, multiple fire door deficiencies were identified through regular inspections and preventive maintenance, including failure of door to fully close, sticky door latches and door locks, broken door latches, broken door, tight fit and rubbing between double doors, passive door unable to open, panic bar and latch not working, degraded bottom sweep, loose, missing and stripped hinge screws and doors dragging on the floor. The degraded fire doors were repaired and parts were replaced, as necessary to restore proper function of the fire doors.
3. Halon System A review of the most recent 10 years of Callaway operating experience was performed and confirmed that the operating experience discussed in NUREG-1801,Section XI.M26 for the halon Halon system is bounding, i.e., that there is no unique plant specific operating experience in addition to that described in NUREG-1801.
4. Fireproofing In 2005, during a fire barrier inspection, a small section of structural steel fireproofing (approximately 1 ft long) was degraded at the ceiling level of Room 3404 (Switchboard Room 4 on 2016 ft elevation of the control building). The affected area was repaired.

Appendix B AGING MANAGEMENT PROGRAMS Callaway Plant Unit 1 Page B-52 License Renewal Application Amendment 1 The above examples provide objective evidence that the fire protection Fire Protection program is capable of detecting and correcting aging effects associated with fire rated doors, fire dampers, fire barrier penetration seals, structural fire barriers, and halon Halon systems within the scope of license renewal. Occurrences that would be identified under the Fire Protection program will be evaluated to ensure there is no significant impact to safe operation of the plant and corrective actions will be taken to prevent recurrence. Guidance for re-evaluation, repair, or replacement is provided for locations where aging is found. There is confidence that the continued implementation of the Fire Protection program will effectively identify aging prior to loss of intended function.

Conclusion The continued implementation of the Fire Protection program, following enhancement, provides reasonable assurance that aging effects will be managed such that the systems and components within the scope of this program will continue to perform their intended functions consistent with the current licensing basis for the period of extended operation.

Appendix B AGING MANAGEMENT PROGRAMS Callaway Plant Unit 1 Page B-53 License Renewal Application Amendment 1 B2.1.14 Fire Water System Program Description The Fire Water System program manages loss of material for water-based fire protection systems consisting of aboveground, buried and underground piping, fittings, valves, fire pump casings, sprinklers, nozzles, hydrants, hose stations, standpipes and water storage tanks. Periodic fire main and hydrant inspections and flushing, sprinkler inspections, functional test, and flow tests in accordance with National Fire Protection Association (NFPA) codes and standards ensure that the water-based fire protection systems are capable of performing their intended function. The fire protection water system is maintained at the required normal operating pressure and monitored such that a loss of system pressure is immediately detected and corrective actions initiated.

The Fire Water System program performs a flow test of the system at least once every three years in accordance with plant procedures meeting the requirements of NFPA 25, including a yard fire loop flush and a flush of associated hydrants. A visual inspection of yard fire hydrants is performed annually.

The Fire Water System program conducts flow tests through each open head spray/sprinkler nozzle in accordance with NFPA 25, to verify water flow is unobstructed.

The Fire Water System program requires replacement of sprinklers prior to 50 years in service, or the program tests a representative sample of the sprinklers and tests another representative sample every 10 years thereafter during the period of extended operation to ensure signs of aging are detected in a timely manner.

Pipe wall thickness examinations are performed on fire water piping using non-intrusive techniques. As an alternative to wall thickness evaluations examinations, internal inspections are performed on accessible exposed portions of fire water piping during plant maintenance activities. The inspections evaluate wall thickness measurements to ensure against catastrophic failure and the inner diameter of the piping as it applies to the design flow of the fire protection system. If a representative number of inspections have not been completed prior to the period of extended operation, Callaway will determine what additional inspections or examinations are required. The representative sample will be selected, based on system susceptibility to corrosion or fouling and evidence of performance degradation during system flow testing or periodic flushes. If material and environment conditions for above grade and below grade piping are similar, the results of the inspections of the internal surfaces of the above grade fire protection water piping can be extrapolated to evaluate the condition of the internal surfaces of the below grade fire protection water piping. If not, additional inspection activities will be performed to ensure that the intended function of below grade fire protection water piping will be maintained consistent with the current licensing basis. Pipe wall thickness examinations and/or internal inspections will be performed prior to the period of extended operation and at 10-year frequencies throughout the period of extended operation.

Appendix B AGING MANAGEMENT PROGRAMS Callaway Plant Unit 1 Page B-54 License Renewal Application Amendment 1 Functional tests are periodically performed on fire detectors to ensure that they are operable.

The fire water storage tank external surfaces are inspected and volumetric examinations of the tank bottom are performed as described in the Aboveground Metallic Tanks program (B2.1.15). External surfaces of buried fire main piping are evaluated as described in the Buried and Underground Piping and Tanks program (B2.1.25).

NUREG-1801 Consistency The Fire Water System program is an existing program that, following enhancement, will be consistent, with exception to NUREG-1801,Section XI.M27, Fire Water System.

Exceptions to NUREG-1801 Program Element Affected:

Detection of Aging Effects (Element 4)

NUREG-1801 requires inspection of fire protection systems in accordance with the guidance of NFPA-25. Callaway performs power block hose station gasket inspections at least once every 18 months. The inspection interval is in accordance with the approved fire protection program, as described in FSAR Table 9.5.1 SP, Section 5.4, rather than annually as specified by NFPA-25.

NUREG-1801 requires annual testing of fire hydrant hose. Callaway hydrostatically tests fire hoses at fire hose stations that are older than five years at least every three years. The testing interval is in accordance with the approved fire protection program, as described in FSAR Table 9.5.1 SP, Section 5.6.

NUREG-1801 requires fire hydrant flow tests to be performed annually. Callaway performs a yard loop and hydrant flush at least once every three years, and a flow test of the system at least once every three years. The testing interval is in accordance with the approved fire protection program, as described in FSAR Table 9.5.1 SP, Sections 2.4 and 2.7.

Enhancements Prior to the period of extended operation, the following enhancements will be implemented in the following program elements:

Parameters Monitored or Inspected (Element 3), and Detection of Aging Effects (Element 4), and Acceptance Criteria (Element 6)

The Fire Water System program will be enhanced to include non-intrusive pipe wall thickness examinations on fire water piping. As an alternative to wall thickness examinations, internal inspections will be performed on accessible exposed portions of fire water piping during plant maintenance activities. Pipe wall thickness examinations

Appendix B AGING MANAGEMENT PROGRAMS Callaway Plant Unit 1 Page B-55 License Renewal Application Amendment 1 and/or internal inspections will be performed prior to the period of extended operation and at 10-year frequencies throughout the period of extended operation.

Detection of Aging Effects (Element 4)

The Fire Water System program will be enhanced to replace sprinkler heads prior to 50 years in service or test a representative sample and test every 10 years thereafter to ensure signs of degradation are detected in a timely manner.

Monitoring and Trending (Element 5)

The Fire Water System program will be enhanced to review and evaluate trends in flow parameters recorded during the NFPA 25 fire water flow tests.

Operating Experience The following discussion of operating experience provides objective evidence that the Fire Water System program will be effective in ensuring that intended functions are maintained consistent with the current licensing basis for the period of extended operation.

1. In 2005, during a surveillance test, 10 sprinkler heads had signs of corrosion or mechanical damage. Two of the sprinkler heads were replaced, and the other eight were cleaned. There have been no additional issues with the sprinkler heads since then.
2. In 2005, an alarm was triggered for fire protection loop jockey pump excessive run time and an investigation was initiated to identify the leak. The location of the leak was determined and promptly isolated from the main fire water loop. The isolation of the leak did not affect any required suppression systems. The leak was promptly repaired and the fire water piping was returned to service.
3. In 2006, a low C-factor lead to the fire water system being chemically cleaned, resulting in removal of approximately 8900 pounds of corrosion products. The cleaning was successful in keeping the system C-factor above 91.5 as required by plant procedure. During the chemical cleaning, five leaks developed, all of which were repaired. Since that time, two additional leaks have occurred. One was due to a cracked valve, and the cause of the other is still under investigation.
4. In 2008, during microbiological sampling of the fire water system, elevated levels of microbiologically influenced corrosion (MIC) were detected in stagnant portions of fire water pipe supplying fire water to hose stations. As a result, a new preventive maintenance task has been created to flush hose stations with a biocide.
5. In 2011, C-factor testing was performed on the main fire loop piping to check for restrictions due to corrosion and or biofouling. The testing results did not meet the acceptance criteria, indicating excessive pressure drop leading to reduced fire water flow. The testing results were called into question so with more accurate digital crystal gauges, the system was reevaluated and the results improved by 6% to 89.5, still less than the required acceptance criteria of 91.5. A functionality determination

Appendix B AGING MANAGEMENT PROGRAMS Callaway Plant Unit 1 Page B-56 License Renewal Application Amendment 1 concluded that provided compensatory measures were taken, the reduced cleanliness could be fully offset so the required fire water flow rate could be achieved and maintained. As a corrective action, the acceptance criteria in Calculation KC-005 Addendum 2 have been modified, and the test procedure updated accordingly.

These revisions provide significant margin and consider the cleanliness trends, ensuring the fire water system is capable of performing its intended function.

The above examples provide objective evidence that the existing Fire Water System program includes activities that are capable of detecting aging effects, evaluating system leakage, and initiating corrective actions. Occurrences that would be identified under the Fire Water System program will be evaluated to ensure there is no significant impact to safe operation of the plant and corrective actions will be taken to prevent recurrence.

Guidance for re-evaluation, repair, or replacement is provided for locations where aging is found. There is confidence that the continued implementation of the Fire Water System program will effectively identify aging prior to loss of intended function.

Conclusion The continued implementation of the Fire Water System program, following enhancement, provides reasonable assurance that aging effects will be managed such that the systems and components within the scope of this program will continue to perform their intended functions consistent with the current licensing basis for the period of extended operation.

Appendix B AGING MANAGEMENT PROGRAMS Callaway Plant Unit 1 Page B-58 License Renewal Application Amendment 1 B2.1.15 Aboveground Metallic Tanks Program Description The Aboveground Metallic Tanks program manages cracking and loss of material on the external surfaces of outdoor, aboveground metallic tanks within the scope of license renewal that are supported on concrete or soil. The program also manages cracking, blistering, and change in color of the acrylic/urethane insulation on the condensate storage tank (CST). The program applies to the CST, refueling water storage tank (RWST), and the two fire water storage tanks (FWSTs). Tanks inside plant structures and protected from the outdoor environment are managed by the External Surfaces Monitoring of Mechanical Components program (B2.1.21).

The Aboveground Metallic Tanks program is a condition monitoring program that performs periodic inspections to monitor for aging effects on the external surfaces of the tank. For the carbon steel FWSTs, the program relies on the application of paint, coatings, or tank bottom edge grout as corrosion preventive measures. For the stainless steel CST and RWST, jacketed insulation with overlapping seams that prevent moisture intrusion or spray-on polyurethane foam insulation that adheres to tank surfaces are used as a corrosion preventive measure. There are no sealants or caulkings applied at the external interfaces between the FWST, CST, and RWST and their concrete or soil foundations.

This program performs visual inspections to monitor for aging of the tank external surface paint or damage of the insulation covering. Removal of the tank insulation is on an opportunistic basis, to permit inspection of the tank external surface for aging.

Insulation is removed for inspection of the tank surface if insulation damage is detected that would permit water ingress to the tank metallic surface. Painted exterior tank metallic surfaces are inspected for signs of degradation such as flaking, cracking, and peeling, to manage loss of material of the metallic surfaces.

Insulated tank exterior surfaces that have not been opportunistically inspected will be examined with ultrasonic test (UT) thickness measurements from the internal surface, to determine the tank wall thickness. Tank wall thickness measurements for insulated tank exterior surfaces that have not had an opportunistic inspection will be performed on a sampling basis when the tank is drained and within five years of entering the period of extended operation.

This program also performs UT thickness measurements of the bottom of the tank from the internal surface, to determine the thickness of the tank bottom. With exception of the FWSTs, tank bottom UT thickness measurements will be performed when the tank is drained and within five years of entering the period of extended operation. Tank bottom UT thickness measurements of each FWST will be performed at least once every 10 years.

The Aboveground Metallic Tanks program is a new program that will be implemented prior to the period of extended operation.

Appendix B AGING MANAGEMENT PROGRAMS Callaway Plant Unit 1 Page B-59 License Renewal Application Amendment 1 NUREG-1801 Consistency The Aboveground Metallic Tanks program is new program that, when implemented, will be consistent with exception to NUREG-1801,Section XI.M29, Aboveground Metallic Tanks.

Exceptions to NUREG-1801 Program Element Affected Detection of Aging Effects (Element 4)

NUREG-1801 requires UT thickness measurements of the tank bottoms whenever the tank is drained and at least once within five years of entering the period of extended operation. UT thickness measurements of the bottom of each FWST from the internal surface, to determine the thickness of the tank bottom will be performed at least once every ten years. Currently the internal surface of each FWST tank bottom will be visually inspected on an alternating refueling outage frequency. UT thickness measurements may be performed sooner if required by further evaluation of the tank bottom visual inspection results. Ten year periodic UT thickness measurements, supplemented when appropriate based on internal visual examinations, will be effective in managing loss of material of the tank bottoms.

Enhancements None Operating Experience The following discussion of operating experience provides objective evidence that the Aboveground Metallic Tanks program will be effective in ensuring that intended functions are maintained consistent with the current licensing basis for the period of extended operation:

1. In 2007, an inspection of the train B fire water storage tank, performed in accordance with the Callaway fire water storage tank inspection procedure, identified small amounts of corrosion and mineral deposits, generally at the weld seams. An evaluation determined another application of the tank coating would be planned. In 2009, an inspection of the train B fire water storage tank identified several areas of blistering in the coating, mainly near the welds, and calcium deposits. No major delaminations were identified, and the anodes were in good shape. Minor corrosion was identified on bare metal surfaces, with no pitting. An evaluation determined that the tank internal surfaces were satisfactory. In 2011, an inspection of the train B fire water storage tank was performed. Little to no damage or degradation was found to the internal metallic surface of the tank. There was some surface roughness/pitting when compared to clean bare metal. General blistering and some local delamination of the coating was found. The blistering on the wall and most of the floor is intact, while there was heavy blistering near the welds with smaller blistering on general plate areas. Since the fire water storage tanks are cathodically protected and most

Appendix B AGING MANAGEMENT PROGRAMS Callaway Plant Unit 1 Page B-60 License Renewal Application Amendment 1 of the blisters were intact, the substrate is not expected to degrade significantly by the next inspection or re-coating, and no repair to the exposed metal is necessary.

2. In 2008, an inspection of the train A fire water storage tank identified minor blistering and limestone deposits. No corrosion was found on the tank internal surface, and the tank cathodic protection was found in satisfactory condition. The internal surface of the tank was determined to be in satisfactory condition. In 2010, an inspection of the train A fire water tank identified discontinuities and delaminations of the coating.

The weld at the floor to wall interface had the most pitting, and weld locations contained heavy blistering. The adjustments on the rectifier of the cathodic protection system were found to be adequate. An evaluation determined that, since the cathodic protection system was determined to be effective, through voltage and current measurements, the substrate would not degrade excessively before the next planned inspection.

The above examples provide objective evidence that the new Aboveground Metallic Tanks program will be capable of detecting the aging effects associated with this program. Occurrences that would be identified under the Aboveground Metallic Tanks program will be evaluated to ensure there is no significant impact to the safe operation of the plant and corrective actions will be taken to prevent recurrence. Guidance for re-evaluation, repair, or replacement is provided for locations where aging is found. There is confidence that the implementation of the Aboveground Metallic Tanks program will effectively identify aging prior to loss of intended function.

Industry and plant-specific operating experience will be evaluated in the development and implementation of this program.

Conclusion The implementation of the Aboveground Metallic Tanks program will provide reasonable assurance that aging effects will be managed such that the systems and components within the scope of this program will continue to perform their intended functions consistent with the current licensing basis for the period of extended operation.

Appendix B AGING MANAGEMENT PROGRAMS Callaway Plant Unit 1 Page B-81 License Renewal Application Amendment 1 B2.1.23 Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components Program Description The Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components program manages cracking, loss of material, hardening and loss of strength. The program inspects internal surfaces exposed to plant indoor air, ventilation atmosphere, atmosphere/weather, condensation, borated water leakage, diesel exhaust, lubricating oil, and any water system environment not managed by Open-Cycle Cooling Water System (B2.1.10), Closed Treated Water System (B2.1.11), Fire Water System (B2.1.14), and Water Chemistry (B2.1.2) programs.

Internal inspections are performed opportunistically whenever the internal surfaces are made accessible, such as periodic system and component surveillance activities or maintenance activities. Visual inspections of internal surfaces of plant components are performed by qualified personnel. For certain materials, such as polymers, visual inspections will be augmented by physical manipulation of at least 10 percent of the accessible surface area or pressurization to detect hardening, loss of strength, and cracking. Volumetric evaluations are performed when appropriate for the component environment and material. Volumetric evaluations such as ultrasonic examinations are used to detect stress corrosion cracking of internal surfaces such as stainless steel components exposed to diesel exhaust.

Identified aging deficiencies are documented and evaluated by the Corrective Action Program. Acceptance criteria are established in the maintenance and surveillance procedures or are established during engineering evaluation of the degraded condition.

If the inspection results are not acceptable, the condition is evaluated to determine whether the component intended function is affected, and a corrective action is implemented.

Components with repetitive failures due to loss of material from corrosion, and all similar component-material-environment combinations, require a plant-specific program, unless the component material has been replaced by a material of more corrosion resistance for the environment of interest.

The Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components program is a new program that will be implemented prior to entering the period of extended operation.

NUREG-1801 Consistency The Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components program is a new program that, when implemented, will be consistent with exception to NUREG-1801,Section XI.M38, Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components.

Appendix B AGING MANAGEMENT PROGRAMS Callaway Plant Unit 1 Page B-82 License Renewal Application Amendment 1 Exceptions to NUREG-1801 Program Elements Affected:

Scope of Program (Element 1), Parameters Monitored or Inspected (Element 3),

Detection of Aging Effects (Element 4), and Monitoring and Trending (Element 5)

NUREG-1801 requires a visual examination of the internal surface of components within the scope of this program. The diesel exhaust is not available for internal surface inspection, so a volumetric examination will be performed for this component. The volumetric examination is adequate for detecting loss of material (wall thinning) and cracking of piping and tubing.

Enhancements None Operating Experience The following discussion of operating experience provides objective evidence that the Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components program will be effective in ensuring that intended functions are maintained consistent with the current licensing basis for the period of extended operation.

1. The Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components program will be a new program at Callaway. Internal surface monitoring through visual inspections conducted during maintenance activities and surveillance testing are already in effect in Callaway. The results of the inspections provide data for performance trending, are an input to work planning and prioritization process, and are communicated in the System Health Reports and System Performance Monitoring Indicators. Plant-specific operating experience since 2000 was reviewed to ensure that the operating experience discussed in the corresponding NUREG-1801 aging management program is bounding, i.e., that there is no unique plant-specific operating experience in addition to that described in NUREG-1801. The review also showed that the Plant Health and Performance Monitoring Program had been effective in maintaining the condition of component internal surfaces.
2. In 2007, during maintenance activities, the threaded tube end plugs on the component cooling B centrifugal charging water pump room cooler were found to have a loss of material due to corrosion as introduced by wear and deformation to the plugs from the repeated assembly/disassembly and cleanings. None of the plugs were leaking. An evaluation determined that 125 plugs would be replaced, future inspections of the room cooler coils would include inspection of tube plugs for loss of material due to corrosion, and results of future plug inspections would be documented on a specified form by engineering replacements would be determined on a case-by-case basis. Later in 2007, the other cooler was inspected and the results were used to create a recommended replacement frequency of 15 years for the plugs the 'A' containment spray pump room cooler was inspected. There was no

Appendix B AGING MANAGEMENT PROGRAMS Callaway Plant Unit 1 Page B-83 License Renewal Application Amendment 1 noticeable damage to the plugs in this cooler. An additional corrective action was to ensure a continuous on-site availability of enough plugs to replace all the plugs in each one room cooler.

Internal inspections conducted during maintenance activities and surveillance testing and the Plant Health and Performance Monitoring Program have been effective in maintaining the condition of component internal surfaces. Occurrences that would be identified under the Internal Surfaces in Miscellaneous Piping and Ducting Components program will be evaluated to ensure there is no significant impact to safe operation of the plant and corrective actions will be taken to prevent recurrence. Guidance for re-evaluation, repair, or replacement is provided for locations where aging is found. There is confidence that the implementation of the Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components program will effectively identify aging prior to loss of intended function.

Industry and plant-specific operating experience will be evaluated in the development and implementation of this program.

Conclusion The implementation of the Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components program will provide reasonable assurance that aging effects will be managed such that the systems and components within the scope of this program will continue to perform their intended functions consistent with the current licensing basis for the period of extended operation.

Appendix B AGING MANAGEMENT PROGRAMS Callaway Plant Unit 1 Page B-116 License Renewal Application Amendment 1 B2.1.35 Insulation Material for Electrical Cables and Connections Not Subject to 10 CFR 50.49 Environmental Qualification Requirements Used in Instrumentation Circuits Program Description The Insulation Material for Electrical Cables and Connections Not Subject to 10 CFR 50.49 Environmental Qualification Requirements Used in Instrumentation Circuits program manages reduced insulation resistance to ensure that cables and connections used in sensitive instrumentation circuits with high voltage low-level current signals within the ex-core neutron monitoring system are capable of performing their intended functions. All high voltage cables to radiation monitors within the scope of license renewal are managed by the Environmental Qualification (EQ) of Electric Components program (B3.2).

The purpose of this program is to provide reasonable assurance that the intended function of cables and connections used in instrumentation circuits with sensitive, low-level current signals that are not subject to the environmental qualification requirements of 10 CFR 50.49 and are exposed to adverse localized environments caused by temperature, radiation, or moisture are maintained consistent with the current licensing basis through the period of extended operation. In most areas, the actual ambient environments (e.g., temperature, radiation, or moisture) are less severe than the plant design environment for those areas.

Calibration or surveillance testsSurveillances are used to manage the aging of the cable insulation and connections for non-EQ ex-core monitors so that the instrumentation circuits perform their intended functions. When an instrumentation channel is found to be out of calibration during routine surveillance testingsurveillances, troubleshooting is performed on the loop, including the instrumentation cable and connections. A review of the calibrationsurveillance results will be completed before the period of extended operation and every 10 years thereafter.

NUREG-1801 Consistency The Insulation Material for Electrical Cables and Connections Not Subject to 10 CFR 50.49 Environmental Qualification Requirements Used in Instrumentation Circuits program is an existing program that, following enhancement, will be consistent with NUREG-1801,Section XI.E2, Insulation Material for Electrical Cables and Connections Not Subject to 10 CFR 50.49 Environmental Qualification Requirements Used in Instrumentation Circuits.

Exceptions to NUREG-1801 None

Appendix B AGING MANAGEMENT PROGRAMS Callaway Plant Unit 1 Page B-117 License Renewal Application Amendment 1 Enhancements Prior to the period of extended operation, the following enhancement will be implemented in the following program elements:

Scope of the Program (Element 1) and Acceptance Criteria (Element 6)

Procedures will be enhanced to identify the scope of cables requiring aging management.

Parameters Monitored or Inspected (Element 3), and Detection of Aging Effects (Element 4), and Corrective Actions (Element 7).

Procedures will be enhanced to require engineering review of calibration testsurveillance results every 10 years.

Corrective Actions (Element 7)

Procedures will be enhanced to ensure corrective actions are initiated when surveillance results do not meet acceptance criteria, and to require an engineering evaluation be performed. When an unacceptable condition or situation is identified, a determination is also made as to whether the review of surveillance results or the cable testing frequency needs to be increased.

Operating Experience The following discussion of operating experience provides objective evidence that the Insulation Material for Electrical Cables and Connections Not Subject to 10 CFR 50.49 Environmental Qualification Requirements Used in Instrumentation Circuits program will be effective in ensuring that intended functions are maintained consistent with the current licensing basis for the period of extended operation.

1. Callaway has had no plant-specific operating experience indicating age-related failures of cables and connections used in sensitive instrumentation circuits with high voltage low-level current signals.

Operating experience with the Insulation Material for Electrical Cables and Connections Not Subject to 10 CFR 50.49 Environmental Qualification Requirements Used in Instrumentation Circuits program have shown Callaway is effective in correcting conditions identified in industry operating experience. Occurrences that would be identified under the Insulation Material for Electrical Cables and Connections Not Subject to 10 CFR 50.49 Environmental Qualification Requirements Used in Instrumentation Circuits program will be evaluated to ensure there is no significant impact to safe operation of the plant and corrective actions will be taken to prevent recurrence. Guidance for re-evaluation, repair, or replacement is provided for locations where aging is found. Therefore, there is confidence that the continued implementation of the Insulation Material for Electrical Cables and Connections Not Subject to 10 CFR 50.49 Environmental Qualification Requirements Used in Instrumentation Circuits program will effectively identify aging prior to loss of intended function.

Appendix B AGING MANAGEMENT PROGRAMS Callaway Plant Unit 1 Page B-118 License Renewal Application Amendment 1 Conclusion The continued implementation of the Insulation Material for Electrical Cables and Connections Not Subject to 10 CFR 50.49 Environmental Qualification Requirements Used in Instrumentation Circuits program, following enhancement, provides reasonable assurance that aging effects will be managed such that the systems and components within the scope of this program will continue to perform their intended functions consistent with the current licensing basis for the period of extended operation.

Appendix B AGING MANAGEMENT PROGRAMS Callaway Plant Unit 1 Page B-118 License Renewal Application Amendment 1 B2.1.36 Inaccessible Power Cables Not Subject to 10 CFR 50.49 Environmental Qualification Requirements Program Description The Inaccessible Power Cables Not Subject to 10 CFR 50.49 Environmental Qualification Requirements program manages reduced insulation resistance of power cables (greater than or equal to 400 V) to minimize aging effects which could potentially lead to failure of the cable's insulation system. The program provides reasonable assurance that the intended functions of inaccessible or underground power cables (greater than or equal to 400 V) that are not subject to the environmental qualification requirements of 10 CFR 50.49 and are exposed to wetting or submergence are maintained consistent with the current licensing basis through the period of extended operation.

Manholes, pits, and the ends of duct banks that contain in-scope non-EQ inaccessible power cables will be inspected for water collection to identify significant moisture.

Significant moisture is defined as periodic exposures to moisture that last more than a few days (e.g., cable wetting or submergence in water). Any collected water is removed.

The inspection includes direct observation that cables are not submerged or immersed in water, cables/splices and cable support structures are intact, and dewatering/drainage systems (i.e., sump pumps) and associated alarms operate properly. This inspection and water removal is performed based on actual plant experience with the inspection frequency being at least annually and after event driven occurrences (such as heavy rain or flooding). In addition, operation of dewatering devices will be inspected prior to any known or predicted heavy rain or flooding events. The first inspection for license renewal is to be completed prior to the period of extended operation.

All inIn-scope non-EQ inaccessible power cables (greater than or equal to 400V) routed through manholes, pits, or duct banks are tested to provide an indication of the conductor insulation condition. Testing that is a proven test and appropriate to the application at the time of the testing will be performed to detect deterioration of the insulation system due to wetting. Cable testing may be a mix of proven testing methods such as dielectric loss (dissipation factor/power factor), AC voltage withstand, partial discharge, step voltage, time domain reflectometry, insulation resistance and polarization index, line resonance analysis, or other testing that is state-of-the-art at the time the tests are performed. The first test for license renewal will be completed prior to the period of extended operation and every six years thereafter.

NUREG-1801 Consistency The Inaccessible Power Cables Not Subject to 10 CFR 50.49 Environmental Qualification Requirements program is an existing program that, following enhancement, will be consistent with NUREG-1801,Section XI.E3, Inaccessible Power Cables Not Subject to 10 CFR 50.49 Environmental Qualification Requirements.

Appendix B AGING MANAGEMENT PROGRAMS Callaway Plant Unit 1 Page B-119 License Renewal Application Amendment 1 Exceptions to NUREG-1801 None Enhancements Prior to the period of extended operation, the following enhancements will be implemented in the program elements:

Scope of the Program (Element 1).

Procedures will be enhanced to identify the power cables, manholes, pits and duct banks that are within the scope of the Inaccessible Power Cables Not Subject to 10 CFR 50.49 Environmental Qualification Requirements program.

Preventive Actions (Element 2), Parameters Monitored or Inspected (Element 3)

Procedures will be enhanced to include periodic inspection of manholes, pits, and duct banks, to ensure powerconfirm cables are not submerged or immersed in water, cables/splices and support structures are not submerged or immersed in water, and to ensure that cable support structures are intact, and dewatering/drainage systems (i.e.,

sump pumps) and associated alarms operate properly. Inspections will be performed at least annually based on water accumulation over time and after event driven occurrences (e.g., heavy rain or flooding). In addition, operation of dewatering devices will be inspected and operation verified prior to any known or predicted heavy rain or flooding events. Power cable subject to significant moisture are tested periodically.

Parameters Monitored or Inspected (Element 3)

Procedures will be enhanced to confirm cables are not submerged or immersed in water, cables/splices and cable support structures are intact, dewatering/drainage systems (i.e., sump pumps) and associated alarms operate properly, and that power cable subject to significant moisture are tested periodically.

Detection of Aging Effects (Element 4)

Procedures will be enhanced to ensure in-scope power cables are tested at least once every six years.

Monitoring and Trending (Element 5)

Procedures will be enhanced to require comparing test results to previous test results to evaluate for additional information on the rate of cable degradation.

Acceptance Criteria (Element 6)

Procedures will be enhanced to ensure confirm cables are not submerged or immersed in water, cables/splices and cable support structures are not submerged or immersed in standing waterintact, and dewatering/drainage systems (i.e., sump pumps) and

Appendix B AGING MANAGEMENT PROGRAMS Callaway Plant Unit 1 Page B-120 License Renewal Application Amendment 1 associated alarms operate properly. Acceptance criteria for cable testing will be defined prior to each test.

Corrective Actions (Element 7)

Procedures will be enhanced to require an engineering evaluation when the test or inspection acceptance criteria are not met.

Operating Experience The following discussion of operating experience provides objective evidence that the Inaccessible Power Cables Not Subject to 10 CFR 50.49 Environmental Qualification Requirements program will be effective in ensuring that intended functions are maintained consistent with the current licensing basis for the period of extended operation.

1. Callaway has beenis performing an inspection of safety related manhole MH01 on a 36 month frequency. Water was found in the manhole in 2003, 2006, and 2009 below medium-voltage safety-related cables, in 2006 all cable was found immersed in water. The evaluation indicates the manhole cover seals were degraded and, since 2009, new seals for the manhole covers have been installed at each inspection of MH01. Inspection frequency was changed from 36 to 6 months. Foundation sealant, drain pipes, and flashing have been installed around MH01 in 2010. PMs were generated to increase inspection frequency to 18 months in 2011The as-found water level in MH01A has dropped from 30 to 15 inches and MH01B from 24 to 2 inches.
2. Cable testing is done periodically with cable insulation resistance testers and megger testing. No degradation of safety related cables has been noted. A new tan delta test for XNB01ESF and plant service transformer feeder cables has been developed and implemented.
3. A new PM has been written and implemented in 2011 to inspect for water level and pump out all in-scope manholes on a weekly basis.
4. A modification to install sump pumps in all in-scope manholes is in progress, five manholes are complete as of March 12, 2012.

Operating experience with the Inaccessible Power Cables Not Subject to 10 CFR 50.49 Environmental Qualification Requirements program has not identified any cable failures as a result of submergence and the water management in manholes has been enhanced. Occurrences that would be identified under the Inaccessible Power Cables Not Subject to 10 CFR 50.49 Environmental Qualification Requirements program will be evaluated to ensure there is no significant impact to safe operation of the plant and corrective actions will be taken to prevent recurrence. Guidance for re-evaluation, repair, or replacement is provided for locations where aging is found. Therefore, there is confidence that the continued implementation of the Inaccessible Power Cables Not Subject to 10 CFR50.49 Environmental Qualification Requirements program will effectively identify aging prior to loss of intended function.

Appendix B AGING MANAGEMENT PROGRAMS Callaway Plant Unit 1 Page B-121 License Renewal Application Amendment 1 Conclusion The continued implementation of the Inaccessible Power Cables Not Subject to 10 CFR 50.49 Environmental Qualification Requirements

program, following enhancements, provides reasonable assurance that aging effects will be managed such that the systems and components within the scope of this program will continue to perform their intended functions consistent with the current licensing basis for the period of extended operation.

Appendix B AGING MANAGEMENT PROGRAMS Callaway Plant Unit 1 Page B-125 License Renewal Application Amendment 1 B2.1.39 Metal Enclosed Bus Program Description The program manages age-related degradation of in-scope non-segregated phase metal enclosed buses. Bus enclosure assemblies (internal and external), bus bar insulation, bus bar insulating supports, and bus bar bolted connections are included. The metal enclosed buses (MEBs) within the scope of this program are the MEBs that provide power to the service water pumps. The service water pumps provide service water to fire protection hose stations in the essential service water pump house via essential service water piping.

The internal portions of bus enclosure assemblies are inspected for cracks, corrosion, foreign debris, excessive dust buildup, and evidence of watermoisture intrusion. Bus insulation is inspected for signs of reduced insulation resistance due to thermal/thermoxidative degradation of organics/thermoplastics, radiation-induced oxidation, moisture/debris intrusion, or ohmic heating, as indicated by embrittlement, cracking, chipping, melting, discoloration, or swelling, which may indicate overheating or aging degradation. The internal bus insulating supports are inspected for structural integrity and signs of cracks. The external portions of the MEBa bus, including gaskets and sealants, are inspected for surface cracking, crazing, scuffing, dimensional change (e.g., ballooning and necking), shrinkage, discoloration, hardening and loss of strength due to elastomer degradation. The external surfaces are inspected for loss of material due to general, pitting, and crevice corrosion. A sample (20 percent of the population with a maximum of 25) of the accessible bolted connections will be inspected for increased resistance of connection due to loosening of bolts using thermography or by measuring connection resistance. For accessible bolted connections that are covered with heat shrink tape, sleeving, insulating boots, etc.,by a visual inspection of the insulating material will be conducted.

The first inspection of the metal enclosed buses, including a sample of bolted connections, will be completed prior to the period of extended operation and every 10five years thereafter. Where visual inspection of insulating material is conducted, the inspection interval of bolted connections will be every five years thereafter.

NUREG-1801 Consistency The Metal Enclosed Bus program is a new program that, when implemented, will be consistent with NUREG-1801,Section XI.E4, Metal Enclosed Bus.

Exceptions to NUREG-1801 None Enhancements None

Appendix B AGING MANAGEMENT PROGRAMS Callaway Plant Unit 1 Page B-126 License Renewal Application Amendment 1 Operating Experience The following discussion of operating experience provides objective evidence that the Metal Enclosed Bus program will be effective in ensuring that intended functions are maintained consistent with the current licensing basis for the period of extended operation.

1. The Metal Enclosed Bus program is a new program for Callaway. Industry operating experience that forms the basis for this program is included in the operating experience element of the corresponding NUREG-1801 aging management program. Plant-specific operating experience was reviewed to ensure that the operating experience discussed in the corresponding NUREG-1801 aging management program is bounding, i.e., that there is no unique plant-specific operating experience in addition to that described in NUREG-1801.
1. The Callaway Corrective Action Program was searched to determine if MEB failures have occurred. Callaway operating experience with the Metal Enclosed Bus program has not identified any corrective actions related to the MEBsbuses within the scope of license renewal. An inspection conducted in the summer of 2010 found no evidence of aging.

Occurrences that would be identified under the Metal Enclosed Bus program will be evaluated to ensure there is no significant impact to safe operation of the plant and corrective actions will be taken to prevent recurrence. Guidance for re-evaluation, repair, or replacement is provided for locations where aging is found. There is confidence that the implementation of the Metal Enclosed Bus program will effectively identify aging prior to loss of intended function.

Industry and plant-specific operating experience will be evaluated in the development and implementation of this program.

Conclusion The implementation of Metal Enclosed Bus program will provide reasonable assurance that aging effects will be managed such that the systems and components within the scope of this program will continue to perform their intended functions consistent with the current licensing basis for the period of extended operation.

ENCLOSURE 3 Callaway Plant Unit 1 License Renewal Application Amendment No. 1 Borated Water Leakage Changes

  • Engineered Safety Features Systems
  • Auxiliary Systems
  • Steam and Power Conversion Systems

Callaway LRA Amendment 1 Borated Water Leakage Changes Affected Pages LRA Section Page Nos LRA Section Page Nos Section 2.3.1.4 2.3-10 Section 3.3.2.1.28 3.3-33 Table 2.3.4-2 2.3-90 Table 3.3-1 3.3-77 Table 3.1.2-2 3.1-86 Table 3.3.2-1 3.3-82 Table 3.1.2-4 3.1-110 Table 3.3.2-2 3.3-86 Section 3.2.2.1.1 3.2-2 Table 3.3.2-4 3.3-94 Section 3.2.2.1.2 3.2-3 Table 3.3.2-5 3.3-100 Section 3.2.2.1.3 3.2-4 Table 3.3.2-6 3.3-105 Section 3.2.2.1.4 3.2-4 Table 3.3.2-7 3.3-107 Table 3.2-1 3.2-11 Table 3.3.2-8 3.3-113 Table 3.2.2-1 3.2-34 Table 3.3.2-9 3.3-117 Table 3.2.2-2 3.2-38 Table 3.3.2-10 3.3-122 Table 3.2.2-3 3.2-40 Table 3.3.2-13 3.3-164 Table 3.2.2-4 3.2-45 Table 3.3.2-19 3.3-199 Table 3.2.2-5 3.2-54 Table 3.3.2-20 3.3-204 Table 3.2.2-6 3.2-67 Table 3.3.2-24 3.3-246 Section 3.3.2.1.1 3.3-4 Table 3.3.2-25 3.3-255 Section 3.3.2.1.4 3.3-7 Table 3.3.2-26 3.3-258 Section 3.3.2.1.5 3.3-8 Table 3.3.2-27 3.3-263 Section 3.3.2.1.6 3.3-9 Table 3.3.2-28 3.3-271 Section 3.3.2.1.7 3.3-10 Section 3.4.2.1.2 3.4-3 Section 3.3.2.1.8 3.3-11 Section 3.4.2.1.3 3.4-4 Section 3.3.2.1.9 3.3-12 Section 3.4.2.1.4 3.4-5 Section 3.3.2.1.10 3.3-13 Section 3.4.2.1.5 3.4-6 Section 3.3.2.1.13 3.3-17 Section 3.4.2.1.6 3.4-8 Section 3.3.2.1.19 3.3-23 Table 3.4-1 3.4-12 Section 3.3.2.1.20 3.3-24 Table 3.4.2-2 3.4-34 Section 3.3.2.1.24 3.3-29 Table 3.4.2-3 3.4-41 Section 3.3.2.1.25 3.3-30 Table 3.4.2-4 3.4-47 Section 3.3.2.1.26 3.3-31 Table 3.4.2-5 3.4-51 Section 3.3.2.1.27 3.3-32 Table 3.4.2-6 3.4-61

Callaway License Renewal Application Amendment 1 Reactor Vessel, Internals, and Reactor Coolant System Revise to add Borated Water Leakage (Ext) to applicable component types and materials that are in the vicinity of components containing borated water.

Section 2.3.1.4, Steam Generators (page 2.3-10), is revised as follows (deleted text with strikethrough and new text is underlined).

System Description

The purpose of the steam generators is to provide heat removal from the reactor coolant system through the generation of steam and also to act as an assured source of steam to the steam driven auxiliary feedwater pump. Feedwater enters the steam generator and is distributed circumferentially around the steam generator by means of a feedwater ring and then flows downward through an annulus between the tube wrapper and shell.

Steam is generated on the shell side and flows upward through the moisture separation to the outlet nozzle at the top of the vessel.

The steam generators consists of the primary and secondary pressure boundaries of the steam generators including all pieces and parts within the pressure boundary and all penetrations out to the safe ends of the penetration nozzles. The primary inlet and outlet nozzles are connected to the reactor coolant system hot and cold legs respectively. The reactor coolant flows through the inverted U-tubes. The secondary inlet nozzle is connected to the main feedwater system and the secondary outlet nozzle is connected to the main steam system.

System Intended Functions The steam generators support the function of inventory and pressure control, heat removal and indirect radioactive release in post accident conditions. The primary channel head and tubes form part of the reactor coolant pressure boundary. The steam generators also provide an assured source of steam to the turbine driven auxiliary feedwater pump. Therefore the steam generators is are within the scope of license renewal based on the criteria of 10 CFR 54.4(a)(1).

Portions of the steam generators are within the scope of license renewal as nonsafety-related affecting safety-related components based on the criterion of 10 CFR 54.4(a)(2).

Failure of nonsafety-related internal components may generate loose parts that prevent accomplishment of the intended function of steam generator tubes.

Portions of the steam generators are within the scope of license renewal to support fire protection and station blackout requirements based upon the criteria of 10 CFR 54.4(a)(3).

Table 3.1.2-2, Reactor Vessel, Internals, and Reactor Coolant System - Summary of Aging Management Evaluation - Reactor Coolant System (page 3.1-86), is revised as follows (deleted text shown with strikethrough and new text is underlined).

Table 3.1.2-2 Reactor Vessel, Internals, and Reactor Coolant System - Summary of Aging Management Evaluation - Reactor Coolant System Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Program NUREG-1801 Item Table 1 Item Notes Piping LBS, PB Carbon Steel Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

IV.C2.R-17 3.1.1.049 A

Table 3.1.2-4, Reactor Vessel, Internals, and Reactor Coolant System - Summary of Aging Management Evaluation - Steam Generators, (page 3.1-110) is revised as follows (deleted text shown with strikethrough and new text is underlined).

Table 3.1.2-4 Reactor Vessel, Internals, and Reactor Coolant System - Summary of Aging Management Evaluation - Steam Generators Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Program NUREG-1801 Item Table 1 Item Notes SG Closure Bolting PB Carbon Steel Plant Indoor Air (Ext)

Cumulative fatigue damage Time-Limited Aging Analysis evaluated for the period of extended operation IV.C2.R-18 3.1.1.005 A

SG Secondary Nozzles PB Carbon Steel Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

IV.D1.R-17 3.1.1.049 A

SG Secondary Shell PB Carbon Steel Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

IV.D1.R-17 3.1.1.049 A

SG Secondary Side Access Covers PB Carbon Steel Plant Indoor Air (Ext) Borated Water Leakage (Ext)

Cumulative fatigue damage Time-Limited Aging Analysis evaluated for the period of extended operation IV.C2.R-18 3.1.1.005 A

SG Secondary Side Access Covers PB Carbon Steel Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

IV.D1.R-17 3.1.1.049 A

Callaway License Renewal Application Amendment 1 Engineered Safety Features Revise to add Borated Water Leakage (Ext) to applicable component types and materials that are in the vicinity of components containing borated water.

Section 3.2.2.1.1, Containment Spray System (page 3.2-2), is revised as follows (deleted text with strikethrough and new text is underlined).

Aging Management Programs The following aging management programs manage the aging effects for the containment spray system component types:

Bolting Integrity (B2.1.8)

Boric Acid Corrosion (B2.1.4)

External Surfaces Monitoring of Mechanical Components (B2.1.21)

Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components (B2.1.23)

One-Time Inspection (B2.1.18)

Water Chemistry (B2.1.2)

Section 3.2.2.1.2, Containment Integrated Leak Rate Testing System (page 3.2-3), is revised as follows (deleted text with strikethrough and new text is underlined).

Environment The containment integrated leak rate testing system components are exposed to the following environments:

Borated Water Leakage Closed Cycle Cooling Water Condensation Plant Indoor Air Aging Management Programs The following aging management programs manage the aging effects for the containment integrated leak rate testing system component types:

Bolting Integrity (B2.1.8)

Boric Acid Corrosion (B2.1.4)

Closed Treated Water Systems (B2.1.11)

External Surfaces Monitoring of Mechanical Components (B2.1.21)

Inspection of Internal Surfaces In Miscellaneous Piping And Ducting Components (B2.1.23)

Section 3.2.2.1.3, Containment Hydrogen Control System (page 3.2-4), is revised as follows (deleted text with strikethrough and new text is underlined).

Environment The containment hydrogen control system component types are exposed to the following environments:

Borated Water Leakage Condensation Dry Gas Plant Indoor Air Aging Management Programs The following aging management programs manage the aging effects for the containment hydrogen control system component types:

Bolting Integrity (B2.1.8)

Boric Acid Corrosion (B2.1.4)

External Surfaces Monitoring of Mechanical Components (B2.1.21)

Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components (B2.1.23)

Section 3.2.2.1.4, Containment Purge System (page 3.2-4), is revised as follows (deleted text with strikethrough and new text is underlined).

Environment The containment purge system component types are exposed to the following environments:

Borated Water Leakage Closed Cycle Cooling Water Condensation Plant Indoor Air

Ventilation Atmosphere Waste Water Aging Management Programs The following aging management programs manage the aging effects for the containment purge system component types:

Bolting Integrity (B2.1.8)

Boric Acid Corrosion (B2.1.4)

Closed Treated Water Systems (B2.1.11)

External Surfaces Monitoring of Mechanical Components (B2.1.21)

Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components (B2.1.23)

Selective Leaching (B2.1.19)

Table 3.2-1, Summary of Aging Management Programs in Chapter V of NUREG-1801 for Engineered Safety Features (page 3.2-11), is revised as follows (deleted text shown with strikethrough and new text is underlined).

Table 3.2-1 Summary of Aging Management Programs in Chapter V of NUREG-1801 for Engineered Safety Features Item Number Component Type Aging Effect / Mechanism Aging Management Program Further Evaluation Recommended Discussion 3.2.1.008 Aluminum, Copper alloy (>15% Zn or

>8% Al) Piping, piping components, and piping elements exposed to Air with borated water leakage Loss of material due to boric acid corrosion Boric Acid Corrosion (B2.1.4)

No Not applicable. Callaway has no in-scope aluminum, copper alloy piping, piping components, or piping elements that are exposed to the environment of air with borated water for aging evaluations in the emergency core cooling system, so the applicable NUREG-1801 line was not used.

Consistent with NUREG-1801.

Table 3.2.2-1, Engineered Safety Features - Summary of Aging Management Evaluation - Containment Spray System (page 3.2-34), is revised as follows (deleted text shown with strikethrough and new text is underlined).

Table 3.2.2-1 Engineered Safety Features - Summary of Aging Management Evaluation - Containment Spray System Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Program NUREG-1801 Item Table 1 Item Notes Piping PB Carbon Steel Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

V.A.E-28 3.2.1.009 A

Table 3.2.2-2, Engineered Safety Features - Summary of Aging Management Evaluation - Containment Integrated Leak Rate Testing System (page 3.2-38), is revised as follows (deleted text shown with strikethrough and new text is underlined).

Table 3.2.2-2 Engineered Safety Features - Summary of Aging Management Evaluation - Containment Integrated Leak Rate Testing System Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Program NUREG-1801 Item Table 1 Item Notes Closure Bolting PB Carbon Steel Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

V.E.E-41 3.2.1.009 A

Piping LBS, PB Carbon Steel Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

V.E.E-28 3.2.1.009 A

Table 3.2.2-3, Engineered Safety Features - Summary of Aging Management Evaluation - Containment Hydrogen Control System (page 3.2-40), is revised as follows (deleted text shown with strikethrough and new text is underlined).

Table 3.2.2-3 Engineered Safety Features - Summary of Aging Management Evaluation - Containment Hydrogen Control System Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Program NUREG-1801 Item Table 1 Item Notes Closure Bolting LBS, PB Carbon Steel Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

V.E.E-41 3.2.1.009 A

Piping LBS, PB, SIA Carbon Steel Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

V.E.E-28 3.2.1.009 A

Table 3.2.2-4, Engineered Safety Features - Summary of Aging Management Evaluation - Containment Purge System (page 3.2-45), is revised as follows (deleted text shown with strikethrough and new text is underlined).

Table 3.2.2-4 Engineered Safety Features - Summary of Aging Management Evaluation - Containment Purge System Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Program NUREG-1801 Item Table 1 Item Notes Closure Bolting LBS, PB, SIA Carbon Steel Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

V.E.E-41 3.2.1.009 A

Ductwork PB Carbon Steel (Galvanized)

Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

V.E.E-28 3.2.1.009 A

Piping LBS, PB, SIA Carbon Steel Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

V.E.E-28 3.2.1.009 A

Pump PB Aluminum Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

V.D1.EP-101 3.2.1.008 A

Table 3.2.2-5, Engineered Safety Features - Summary of Aging Management Evaluation - High Pressure Coolant Injection System (page 3.2-54), is revised as follows (deleted text shown with strikethrough and new text is underlined).

Table 3.2.2-5 Engineered Safety Features - Summary of Aging Management Evaluation - High Pressure Coolant Injection System Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Program NUREG-1801 Item Table 1 Item Notes Closure Bolting LBS, PB, SIA Carbon Steel Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

V.E.E-41 3.2.1.009 A Piping LBS, PB, SIA Carbon Steel Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

V.D1.E-28 3.2.1.009 A Tank PB Carbon Steel Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

V.D1.E-28 3.2.1.009 A

Table 3.2.2-6, Engineered Safety Features - Summary of Aging Management Evaluation - Residual Heat Removal System (page 3.2-67), is revised as follows (deleted text shown with strikethrough and new text is underlined).

Table 3.2.2-6 Engineered Safety Features - Summary of Aging Management Evaluation - Residual Heat Removal System Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Program NUREG-1801 Item Table 1 Item Notes Expansion Joint PB Carbon Steel Plant Indoor Air (Ext)

Loss of material External Surfaces Monitoring of Mechanical Components (B2.1.21)

V.E.E-44 3.2.1.040 A

Heat Exchanger (Residual Heat Removal)

PB Carbon Steel Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

V.D1.E-28 3.2.1.009 A

Heat Exchanger (RHR Pump Seal Water Cooler)

PB Carbon Steel Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

V.D1.E-28 3.2.1.009 A

Insulation INS Aluminum Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

V.D1.EP-101 3.2.1.008 C

Piping LBS, PB, SIA Carbon Steel Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

V.D1.E-28 3.2.1.009 A

Piping LBS, SIA Carbon Steel Condensation (Int)

Loss of material Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components (B2.1.23)

V.A.E-29 3.2.1.044 B

Callaway License Renewal Application Amendment 1 Auxiliary Systems Revise to add Borated Water Leakage (Ext) to applicable component types and materials that are in the vicinity of components containing borated water.

Section 3.3.2.1.1, Fuel Storage and Handling System (page 3.3-4), is revised as follows (deleted text with strikethrough and new text is underlined).

Environment The fuel storage and handling system components are exposed to the following environments:

Borated Water Leakage Plant Indoor Air Treated Borated Water Aging Management Programs The following aging management programs manage the aging effects for the fuel storage and handling system component types:

Boric Acid Corrosion (B2.1.4)

External Surfaces Monitoring of Mechanical Components (B2.1.21)

Inspection of Overhead Heavy Load and Light Load (Related to Refueling) Handling Systems (B2.1.12)

Monitoring of Neutron-Absorbing Materials Other than Boraflex (B2.1.38)

One-Time Inspection (B2.1.18)

Structures Monitoring (B2.1.31)

Water Chemistry (B2.1.2)

Section 3.3.2.1.4, Essential Service Water System (page 3.3-7), is revised as follows (deleted text with strikethrough and new text is underlined).

Environment The essential service water system components are exposed to the following environments:

Atmosphere/ Weather

Borated Water Leakage Buried Concrete Condensation Plant Indoor Air Raw Water Underground Aging Management Programs The following aging management programs manage the aging effects for the essential service water system component types:

Bolting Integrity (B2.1.8)

Boric Acid Corrosion (B2.1.4)

Buried and Underground Piping and Tanks (B2.1.25)

External Surfaces Monitoring of Mechanical Components (B2.1.21)

Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components (B2.1.23)

Open-Cycle Cooling Water System (B2.1.10)

Selective Leaching (B2.1.19)

Section 3.3.2.1.5, Service Water System (page 3.3-8), is revised as follows (deleted text with strikethrough and new text is underlined).

Environment The service water system components are exposed to the following environments:

Borated Water Leakage Buried Plant Indoor Air Raw Water Aging Management Programs The following aging management programs manage the aging effects for the service water system component types:

Bolting Integrity (B2.1.8)

Boric Acid Corrosion (B2.1.4)

Buried and Underground Piping and Tanks (B2.1.25)

External Surfaces Monitoring of Mechanical Components (B2.1.21)

Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components (B2.1.23)

Selective Leaching (B2.1.19)

Section 3.3.2.1.6, Reactor Makeup Water System (page 3.3-9), is revised as follows (deleted text with strikethrough and new text is underlined).

Environment The reactor makeup water system components are exposed to the following environments:

Borated Water Leakage Condensation Demineralized Water Plant Indoor Air Aging Management Programs The following aging management programs manage the aging effects for the reactor makeup water system component types:

Bolting Integrity (B2.1.8)

Boric Acid Corrosion (B2.1.4)

Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components (B2.1.23)

One-Time Inspection (B2.1.18)

Water Chemistry (B2.1.2)

Section 3.3.2.1.7, Component Cooling Water System (page 3.3-10), is revised as follows (deleted text with strikethrough and new text is underlined).

Environment The component cooling water system component types are exposed to the following environments:

Borated Water Leakage Closed-Cycle Cooling Water Condensation Plant Indoor Air Raw Water

Aging Management Programs The following aging management programs manage the aging effects for the component cooling water system component types:

Bolting Integrity (B2.1.8)

Boric Acid Corrosion (B2.1.4)

Closed Treated Water Systems (B2.1.11)

External Surfaces Monitoring of Mechanical Components (B2.1.21)

Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components (B2.1.23)

Open-Cycle Cooling Water System (B2.1.10)

Section 3.3.2.1.8, Compressed Air System (page 3.3-11), is revised as follows (deleted text with strikethrough and new text is underlined).

Environment The compressed air system component types are exposed to the following environments:

Borated Water Leakage Condensation Dry Gas Plant Indoor Air Aging Management Programs The following aging management programs manage the aging effects for the compressed air system component types:

Bolting Integrity (B2.1.8)

Boric Acid Corrosion (B2.1.4)

External Surfaces Monitoring of Mechanical Components (B2.1.21)

Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components (B2.1.23)

Section 3.3.2.1.9, Nuclear Sampling System (page 3.3-12), is revised as follows (deleted text with strikethrough and new text is underlined).

Aging Management Programs The following aging management programs manage the aging effects for the nuclear sampling system component types:

Bolting Integrity (B2.1.8)

Boric Acid Corrosion (B2.1.4)

Closed Treated Water Systems (B2.1.11)

External Surfaces Monitoring of Mechanical Components (B2.1.21)

Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components (B2.1.23)

One-Time Inspection (B2.1.18)

Water Chemistry (B2.1.2)

Section 3.3.2.1.10, Chemical and Volume Control System (page 3.3-13), is revised as follows (deleted text with strikethrough and new text is underlined).

Aging Management Programs The following aging management programs manage the aging effects for the chemical and volume control system component types:

ASME Section XI Inservice Inspection, Subsections IWB, IWC, and IWD (B2.1.1)

Bolting Integrity (B2.1.8)

Boric Acid Corrosion (B2.1.4)

Closed Treated Water Systems (B2.1.11)

External Surfaces Monitoring of Mechanical Components (B2.1.21)

Flow-Accelerated Corrosion (B2.1.7)

Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components (B2.1.23)

Lubricating Oil Analysis (B2.1.24)

One-Time Inspection (B2.1.18)

One-Time Inspection of ASME Code Class 1 Small-Bore Piping (B2.1.20)

Selective Leaching (B2.1.19)

Water Chemistry (B2.1.2)

Section 3.3.2.1.13, Auxiliary Building HVAC System (page 3.3-17), is revised as follows (deleted text with strikethrough and new text is underlined).

Environment The auxiliary building HVAC system component types are exposed to the following environments:

Borated Water Leakage Closed-Cycle Cooling Water Concrete

Condensation Plant Indoor Air Raw Water Ventilation Atmosphere Waste Water Aging Management Programs The following aging management programs manage the aging effects for the auxiliary building HVAC system component types:

Bolting Integrity (B2.1.8)

Boric Acid Corrosion (B2.1.4)

Closed Treated Water Systems (B2.1.11)

External Surfaces Monitoring of Mechanical Components (B2.1.21)

Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components (B2.1.23)

Open-Cycle Cooling Water System (B2.1.10)

Selective Leaching (B2.1.19)

Section 3.3.2.1.19, Containment Cooling System (page 3.3-23), is revised as follows (deleted text with strikethrough and new text is underlined).

Environment The containment cooling system component types are exposed to the following environments:

Borated Water Leakage Plant Indoor Air Raw Water Ventilation Atmosphere Waste Water Aging Management Programs The following aging management programs manage the aging effects for the containment cooling system component types:

Bolting Integrity (B2.1.8)

Boric Acid Corrosion (B2.1.4)

External Surfaces Monitoring of Mechanical Components (B2.1.21)

Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components (B2.1.23)

Open-Cycle Cooling Water System (B2.1.10)

Section 3.3.2.1.20, Fire Protection System (page 3.3-24), is revised as follows (deleted text with strikethrough and new text is underlined).

Environment The fire protection system component types are exposed to the following environments:

Atmosphere/ Weather Borated Water Leakage Buried Closed-Cycle Cooling Water Condensation Diesel Exhaust Dry Gas Fuel Oil Plant Indoor Air Raw Water Waste Water Aging Management Programs The following aging management programs manage the aging effects for the fire protection system component types:

Aboveground Metallic Tanks (B2.1.15)

Bolting Integrity (B2.1.8)

Boric Acid Corrosion (B2.1.4)

Buried and Underground Piping and Tanks (B2.1.25)

Closed Treated Water Systems (B2.1.11)

External Surfaces Monitoring of Mechanical Components (B2.1.21)

Fire Protection (B2.1.13)

Fire Water System (B2.1.14)

Fuel Oil Chemistry (B2.1.16)

Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components (B2.1.23)

One-Time Inspection (B2.1.18)

Selective Leaching (B2.1.19)

Section 3.3.2.1.24, Liquid Radwaste System (page 3.3-29), is revised as follows (deleted text with strikethrough and new text is underlined).

Aging Management Programs The following aging management programs manage the aging effects for the liquid radwaste system component types:

Bolting Integrity (B2.1.8)

Boric Acid Corrosion (B2.1.4)

Closed Treated Water Systems (B2.1.11)

External Surfaces Monitoring of Mechanical Components (B2.1.21)

Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components (B2.1.23)

One-Time Inspection (B2.1.18)

Water Chemistry (B2.1.2)

Section 3.3.2.1.25, Decontamination System (page 3.3-30), is revised as follows (deleted text with strikethrough and new text is underlined).

Environment The decontamination system component types are exposed to the following environments:

Borated Water Leakage Condensation Demineralized Water Plant Indoor Air Steam Aging Management Programs The following aging management programs manage the aging effects for the decontamination system component types:

Bolting Integrity (B2.1.8)

Boric Acid Corrosion (B2.1.4)

External Surfaces Monitoring of Mechanical Components (B2.1.21)

Flow-Accelerated Corrosion (B2.1.7)

Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components (B2.1.23)

One-Time Inspection (B2.1.18)

Water Chemistry (B2.1.2)

Section 3.3.2.1.26, Oily Waste System (page 3.3-31), is revised as follows (deleted text with strikethrough and new text is underlined).

Environment The oily waste system component types are exposed to the following environments:

Borated Water Leakage Concrete Condensation Plant Indoor Air Waste Water Aging Management Programs The following aging management programs manage the aging effects for the oily waste system component types:

Bolting Integrity (B2.1.8)

Boric Acid Corrosion (B2.1.4)

External Surfaces Monitoring of Mechanical Components (B2.1.21)

Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components (B2.1.23)

Selective Leaching (B2.1.19)

Section 3.3.2.1.27, Floor and Equipment Drainage System (page 3.3-32), is revised as follows (deleted text with strikethrough and new text is underlined).

Aging Management Programs The following aging management programs manage the aging effects for the floor and equipment drainage system component types:

Bolting Integrity (B2.1.8)

Boric Acid Corrosion (B2.1.4)

External Surfaces Monitoring of Mechanical Components (B2.1.21)

Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components (B2.1.23)

Section 3.3.2.1.28, Miscellaneous Systems In-Scope ONLY based on Criterion 10 CFR 54.4(a)(2) (page 3.3-33), is revised as follows (deleted text with strikethrough and new text is underlined).

Materials The materials of construction for the miscellaneous systems in scope ONLY based on Criterion 10 CFR 54.4(a)(2) component types are:

Carbon Steel Carbon Steel (Galvanized)

Cast Iron Cast Iron (Gray Cast Iron)

Copper Alloy Elastomer Glass Stainless Steel Stainless Steel Cast Austenitic Aging Management Programs The following aging management programs manage the aging effects for the miscellaneous systems in scope ONLY based on Criterion 10 CFR 54.4(a)(2) component types:

Bolting Integrity (B2.1.8)

Boric Acid Corrosion (B2.1.4)

Closed Treated Water Systems (B2.1.11)

External Surfaces Monitoring of Mechanical Components (B2.1.21)

Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components (B2.1.23)

One-Time Inspection (B2.1.18)

Selective Leaching (B2.1.19)

Water Chemistry (B2.1.2)

Table 3.3-1, Summary of Aging Management Programs in Chapter VII of NUREG-1801 for Auxiliary Systems (page 3.3-77), is revised as follows (deleted text shown with strikethrough and new text is underlined).

Table 3.3-1 Summary of Aging Management Programs in Chapter VII of NUREG-1801 for Auxiliary Systems Item Number Component Type Aging Effect / Mechanism Aging Management Program Further Evaluation Recommended Discussion 3.3.1.115 Copper alloy (15%

Zn and 8% Al)

Piping, piping components, and piping elements exposed to Air with borated water leakage None None NA - No AEM or AMP Not applicable. Callaway has no in-scope copper alloy piping, piping components or piping elements exposed to air with borated water leakage in the auxiliary systems, so the applicable NUREG-1801 line was not used.

Consistent with NUREG-1801.

Table 3.3.2-1, Auxiliary Systems - Summary of Aging Management Evaluation - Fuel Storage and Handling System (page 3.3-82), is revised as follows (deleted text shown with strikethrough and new text is underlined).

Table 3.3.2-1 Auxiliary Systems - Summary of Aging Management Evaluation - Fuel Storage and Handling System Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Program NUREG-1801 Item Table 1 Item Notes Bolting (Structural)

SS Carbon Steel Borated Water Leakage (Ext)

Loss of preload Inspection of Overhead Heavy Load and Light Load (Related to Refueling) Handling Systems (B2.1.12)

III.B4.TP-261 3.5.1.088 E, 4 Bolting (Structural)

SS Carbon Steel Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

VII.I.A-102 3.3.1.009 A

Fuel Handling Equip SS Carbon Steel Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

VII.I.A-79 3.3.1.009 A

Table 3.3.2-2, Auxiliary Systems - Summary of Aging Management Evaluation - Fuel Pool Cooling and Cleanup System (page 3.3-86), is revised as follows (deleted text shown with strikethrough and new text is underlined).

Table 3.3.2-2 Auxiliary Systems - Summary of Aging Management Evaluation - Fuel Pool Cooling and Cleanup System Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Program NUREG-1801 Item Table 1 Item Notes Piping LBS, PB, SIA Carbon Steel Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

VII.A3.A-79 3.3.1.009 A

Table 3.3.2-4, Auxiliary Systems - Summary of Aging Management Evaluation - Essential Service Water System (page 3.3-94), is revised as follows (deleted text shown with strikethrough and new text is underlined).

Table 3.3.2-4 Auxiliary Systems - Summary of Aging Management Evaluation - Essential Service Water System Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Program NUREG-1801 Item Table 1 Item Notes Closure Bolting LBS, PB, SIA Carbon Steel Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

VII.I.A-102 3.3.1.009 A

Piping LBS, PB, SIA Carbon Steel Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

VII.I.A-79 3.3.1.009 A

Table 3.3.2-5, Auxiliary Systems - Summary of Aging Management Evaluation - Service Water System (page 3.3-100), is revised as follows (deleted text shown with strikethrough and new text is underlined).

Table 3.3.2-5 Auxiliary Systems - Summary of Aging Management Evaluation - Service Water System Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Program NUREG-1801 Item Table 1 Item Notes Closure Bolting LBS, SIA Carbon Steel Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

VII.I.A-102 3.3.1.009 A

Piping LBS, PB, SIA Carbon Steel Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

VII.I.A-79 3.3.1.009 A

Table 3.3.2-6, Auxiliary Systems - Summary of Aging Management Evaluation - Reactor Makeup Water System (page 3.3-105), is revised as follows (deleted text shown with strikethrough and new text is underlined).

Table 3.3.2-6 Auxiliary Systems - Summary of Aging Management Evaluation - Reactor Makeup Water System Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Program NUREG-1801 Item Table 1 Item Notes Closure Bolting LBS, PB, SIA Carbon Steel Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

VII.I.A-102 3.3.1.009 A

Table 3.3.2-7, Auxiliary Systems - Summary of Aging Management Evaluation - Component Cooling Water System (page 3.3-107), is revised as follows (deleted text shown with strikethrough and new text is underlined).

Table 3.3.2-7 Auxiliary Systems - Summary of Aging Management Evaluation - Component Cooling Water System Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Program NUREG-1801 Item Table 1 Item Notes Closure Bolting LBS, PB, SIA Carbon Steel Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

VII.I.A-102 3.3.1.009 A

Heat Exchanger (CCW Heat Exchanger)

PB Carbon Steel Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

VII.I.A-79 3.3.1.009 A

Piping LBS, PB, SIA Carbon Steel Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

VII.I.A-79 3.3.1.009 A

Piping LBS, PB Carbon Steel Raw Water (Int) Loss of material Open-Cycle Cooling Water System (B2.1.10)

VII.C1.AP-183 3.3.1.038 C

Pump PB Carbon Steel Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

VII.I.A-79 3.3.1.009 A

Tank LBS, PB, SIA Carbon Steel Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

VII.I.A-79 3.3.1.009 A

Table 3.3.2-7 Auxiliary Systems - Summary of Aging Management Evaluation - Component Cooling Water System Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Program NUREG-1801 Item Table 1 Item Notes Tank LBS, PB, SIA Carbon Steel Condensation (Int)

Loss of material Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components (B2.1.23)

VII.G.A-23 3.3.1.089 D

Table 3.3.2-8, Auxiliary Systems - Summary of Aging Management Evaluation - Compressed Air System (page 3.3-113), is revised as follows (deleted text shown with strikethrough and new text is underlined).

Table 3.3.2-8 Auxiliary Systems - Summary of Aging Management Evaluation - Compressed Air System Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Program NUREG-1801 Item Table 1 Item Notes Closure Bolting PB, SIA Carbon Steel Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

VII.I.A-102 3.3.1.009 A

Closure Bolting PB, SIA Copper Alloy Borated Water Leakage (Ext)

Loss of preload Bolting Integrity (B2.1.8)

VII.I.AP-261 3.3.1.015 A

Piping LBS, PB, SIA Carbon Steel Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

VII.I.A-79 3.3.1.009 A

Piping PB, SIA Copper Alloy Borated Water Leakage (Ext)

None None VII.J.AP-11 3.3.1.115 A

Piping LBS, PB, SIA Copper Alloy Condensation (Int) Loss of material Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components (B2.1.23)

VII.D.AP-240 3.3.1.054 E, 1

Table 3.3.2-9, Auxiliary Systems - Summary of Aging Management Evaluation - Nuclear Sampling System (page 3.3-117), is revised as follows (deleted text shown with strikethrough and new text is underlined).

Table 3.3.2-9 Auxiliary Systems - Summary of Aging Management Evaluation - Nuclear Sampling System Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Program NUREG-1801 Item Table 1 Item Notes Piping LBS, SIA Carbon Steel Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

VII.I.A-79 3.3.1.009 A

Table 3.3.2-10, Auxiliary Systems - Summary of Aging Management Evaluation - Chemical and Volume Control System (page 3.3-122), is revised as follows (deleted text shown with strikethrough and new text is underlined).

Table 3.3.2-10 Auxiliary Systems - Summary of Aging Management Evaluation - Chemical and Volume Control System Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Program NUREG-1801 Item Table 1 Item Notes Chiller LBS Cast Iron Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

VII.E1.A-79 3.3.1.009 A

Closure Bolting LBS, PB, SIA Carbon Steel Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

VII.I.A-102 3.3.1.009 A

Condenser SIA Carbon Steel Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

VII.E1.A-79 3.3.1.009 A

Filter LBS Copper Alloy Borated Water Leakage (Ext)

None None VII.J.AP-11 3.3.1.115 A

Heat Exchanger (CVCS BTRS Letdown Chiller)

LBS Carbon Steel Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

VII.E1.A-79 3.3.1.009 A

Heat Exchanger (CVCS Excess Letdown)

PB Carbon Steel Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

VII.E1.A-79 3.3.1.009 A

Table 3.3.2-10 Auxiliary Systems - Summary of Aging Management Evaluation - Chemical and Volume Control System Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Program NUREG-1801 Item Table 1 Item Notes Heat Exchanger (CVCS Letdown)

PB Carbon Steel Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

VII.E1.A-79 3.3.1.009 A

Heat Exchanger (CVCS Seal Water Return)

PB Carbon Steel Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

VII.E1.A-79 3.3.1.009 A

Insulation INS Aluminum Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

VII.E1.AP-1 3.3.1.009 C

Piping LBS, PB, SIA Carbon Steel Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

VII.E1.AP-79 3.3.1.009 A

Piping PB, SIA Carbon Steel Dry Gas (Int)

None None VII.J.AP-6 3.3.1.121 A

Piping LBS, PB Carbon Steel Lubricating Oil (Int)

Loss of material Lubricating Oil Analysis (B2.1.24) and One-Time Inspection (B2.1.18)

VII.E1.AP-127 3.3.1.097 A

Pump LBS Carbon Steel Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

VII.E1.AP-79 3.3.1.009 A

Pump LBS Cast Iron Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

VII.E1.AP-79 3.3.1.009 A

Tank LBS Carbon Steel Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

VII.E1.AP-79 3.3.1.009 A

Solenoid Valve LBS Copper Alloy (>15%

Zinc)

Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

VII.I.AP-66 3.3.1.009 A

Strainer LBS Copper Alloy Borated Water Leakage (Ext)

None None VII.J.AP-11 3.3.1.115 A

Valve LBS Copper Alloy (>15%

Zinc)

Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

VII.I.AP-66 3.3.1.009 A

Table 3.3.2-13, Auxiliary Systems - Summary of Aging Management Evaluation - Auxiliary Building HVAC System (page 3.3-164), is revised as follows (deleted text shown with strikethrough and new text is underlined).

Table 3.3.2-13 Auxiliary Systems - Summary of Aging Management Evaluation - Auxiliary Building HVAC System Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Program NUREG-1801 Item Table 1 Item Notes Closure Bolting PB Carbon Steel Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

VII.I.A-102 3.3.1.009 A

Ductwork PB Carbon Steel (Galvanized)

Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

VII.I.A-79 3.3.1.009 A

Piping LBS, PB, SIA Carbon Steel Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

VII.I.A-79 3.3.1.009 A

Piping LBS, SIA Carbon Steel Closed Cycle Cooling Water (Int)

Loss of material Closed Treated Water Systems (B2.1.11)

VII.F2.AP-202 3.3.1.045 A

Piping LBS, PB, SIA Carbon Steel Ventilation Atmosphere (Int)

Loss of material Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components (B2.1.23)

VII.F2.A-08 3.3.1.090 D

Piping LBS, PB, SIA Carbon Steel Waste Water (Int)

Loss of material Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components (B2.1.23)

VII.E5.AP-281 3.3.1.091 B, 3 Pump LBS Cast Iron (Gray Cast Iron)

Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

VII.I.A-79 3.3.1.009 A

Table 3.3.2-19, Auxiliary Systems - Summary of Aging Management Evaluation - Containment Cooling System (page 3.3-199), is revised as follows (deleted text shown with strikethrough and new text is underlined).

Table 3.3.2-19 Auxiliary Systems - Summary of Aging Management Evaluation - Containment Cooling System Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Program NUREG-1801 Item Table 1 Item Notes Closure Bolting LBS, PB Carbon Steel Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

VII.I.A-102 3.3.1.009 A

Fan PB Carbon Steel Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

VII.I.A-79 3.3.1.009 A

Heat Exchanger Housing PB Carbon Steel (Galvanized)

Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

VII.I.A-79 3.3.1.009 A

Piping LBS, PB Carbon Steel Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

VII.I.A-79 3.3.1.009 A

Table 3.3.2-20, Auxiliary Systems - Summary of Aging Management Evaluation - Fire Protection System (page 3.3-204), is revised as follows (deleted text shown with strikethrough and new text is underlined).

Table 3.3.2-20 Auxiliary Systems - Summary of Aging Management Evaluation - Fire Protection System Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Program NUREG-1801 Item Table 1 Item Notes Closure Bolting PB Carbon Steel Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

VII.I.A-102 3.3.1.009 A

Closure Bolting PB Copper Alloy Borated Water Leakage (Ext)

Loss of preload Bolting Integrity (B2.1.8)

VII.I.AP-261 3.3.1.015 A

Hose Station PB Copper Alloy Borated Water Leakage (Ext)

None None VII.J.AP-11 3.3.1.115 C

Piping PB, SIA Carbon Steel Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

VII.I.A-79 3.3.1.009 A

Table 3.3.2-20 Auxiliary Systems - Summary of Aging Management Evaluation - Fire Protection System Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Program NUREG-1801 Item Table 1 Item Notes Piping PB, SIA, SP Copper Alloy Borated Water Leakage (Ext)

None None VII.J.AP-11 3.3.1.115 A

Piping PB, SP Copper Alloy Condensation (Int)

Loss of material Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components (B2.1.23)

VII.G.AP-143 3.3.1.089 B

Piping PB, SIA Copper Alloy Raw Water (Int) Loss of material Fire Water System (B2.1.14)

VII.G.AP-197 3.3.1.064 B

Piping (Halon) PB Carbon Steel Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

VII.I.A-79 3.3.1.009 A

Tank PB Carbon Steel Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

VII.I.A-79 3.3.1.009 A

Tank PB Cast Iron (Gray Cast Iron)

Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

VII.I.A-79 3.3.1.009 A

Tank (Halon)

PB Carbon Steel Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

VII.I.A-79 3.3.1.009 A

Valve (Halon)

PB Copper Alloy Borated Water Leakage (Ext)

None None VII.J.AP-11 3.3.1.115 A

Table 3.3.2-24, Auxiliary Systems - Summary of Aging Management Evaluation - Liquid Radwaste System (page 3.3-246), is revised as follows (deleted text shown with strikethrough and new text is underlined).

Table 3.3.2-24 Auxiliary Systems - Summary of Aging Management Evaluation - Liquid Radwaste System Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Program NUREG-1801 Item Table 1 Item Notes Closure Bolting PB, SIA Carbon Steel Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

VII.I.A-102 3.3.1.009 A

Heat Exchanger (RCDT Heat Exchanger)

PB Carbon Steel Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

VII.I.A-79 3.3.1.009 A

Piping LBS, PB, SIA Carbon Steel Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

VII.I.A-79 3.3.1.009 A

Table 3.3.2-25, Auxiliary Systems - Summary of Aging Management Evaluation - Decontamination System (page 3.3-255), is revised as follows (deleted text shown with strikethrough and new text is underlined).

Table 3.3.2-25 Auxiliary Systems - Summary of Aging Management Evaluation - Decontamination System Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Program NUREG-1801 Item Table 1 Item Notes Closure Bolting LBS, SIA Carbon Steel Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

VII.I.A-102 3.3.1.009 A

Piping LBS, PB, SIA Carbon Steel Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

VII.I.A-79 3.3.1.009 A

Table 3.3.2-26, Auxiliary Systems - Summary of Aging Management Evaluation - Oily Waste System (page 3.3-258), is revised as follows (deleted text shown with strikethrough and new text is underlined).

Table 3.3.2-26 Auxiliary Systems - Summary of Aging Management Evaluation - Oily Waste System Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Program NUREG-1801 Item Table 1 Item Notes Closure Bolting LBS Carbon Steel Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

VII.I.A-102 3.3.1.009 A

Piping LBS, PB Carbon Steel Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

VII.I.A-79 3.3.1.009 A

Piping LBS, PB Carbon Steel Waste Water (Int)

Loss of material Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components (B2.1.23)

VII.E5.AP-281 3.3.1.091 B

Table 3.3.2-27, Auxiliary Systems - Summary of Aging Management Evaluation - Floor and Equipment Drainage System (page 3.3-263), is revised as follows (deleted text shown with strikethrough and new text is underlined).

Table 3.3.2-27 Auxiliary Systems - Summary of Aging Management Evaluation - Floor and Equipment Drainage System Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Program NUREG-1801 Item Table 1 Item Notes Closure Bolting LBS, PB, SIA Carbon Steel Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

VII.I.A-102 3.3.1.009 A

Piping LBS, PB, SIA Carbon Steel Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

VII.I.A-79 3.3.1.009 A

Piping LBS, PB, SIA Carbon Steel Waste Water (Int)

Loss of material Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components (B2.1.23)

VII.E5.AP-281 3.3.1.091 B

Splash Guard DF Carbon Steel Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

VII.I.A-79 3.3.1.009 A

Table 3.3.2-28, Auxiliary Systems - Summary of Aging Management Evaluation - Miscellaneous Systems in scope ONLY for Criterion 10 CFR 54.4(a)(2) (page 3.3-271), is revised as follows (deleted text shown with strikethrough and new text is underlined).

Table 3.3.2-28 Auxiliary Systems - Summary of Aging Management Evaluation - Miscellaneous Systems in scope ONLY for Criterion 10 CFR 54.4(a)(2)

Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Program NUREG-1801 Item Table 1 Item Notes Closure Bolting LBS Carbon Steel Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

VII.I.A-102 3.3.1.009 A

Closure Bolting LBS Carbon Steel Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

VIII.H.S-40 3.4.1.004 A

Closure Bolting LBS Copper Alloy Borated Water Leakage (Ext)

Loss of preload Bolting Integrity (B2.1.8) VII.I.AP-261 3.3.1.015 A

Eyewash Station LBS Copper Alloy Borated Water Leakage (Ext)

None None VII.J.AP-11 3.3.1.115 C

Piping LBS, SIA Carbon Steel Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

VII.I.A-79 3.3.1.009 A

Piping LBS, SIA Carbon Steel Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

VIII.H.S-30 3.4.1.004 A

Piping LBS, SIA Carbon Steel Condensation (Int)

Loss of material Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components (B2.1.23)

VII.E5.AP-280 3.3.1.095 B

Piping SIA Carbon Steel Dry Gas (Int)

None None VII.J.AP-6 3.3.1.121 A

Piping LBS Copper Alloy Borated Water Leakage (Ext)

None None VII.J.AP-11 3.3.1.115 A

Pump LBS Cast Iron (Gray Cast Iron)

Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

VII.I.A-79 3.3.1.009 A

Table 3.3.2-28 Auxiliary Systems - Summary of Aging Management Evaluation - Miscellaneous Systems in scope ONLY for Criterion 10 CFR 54.4(a)(2)

Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Program NUREG-1801 Item Table 1 Item Notes Sight Gauge LBS Carbon Steel Plant Indoor Air (Ext)

Loss of material External Surfaces Monitoring of Mechanical Components (B2.1.21)

VII.I.A-77 3.3.1.078 A

Sight Gauge LBS Carbon Steel Waste Water (Int)

Loss of material Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components (B2.1.23)

VII.E5.AP-281 3.3.1.091 B

Callaway License Renewal Application Amendment 1 Main Steam Supply System Revise to add Borated Water Leakage (Ext) to applicable component types and materials that are in the vicinity of components containing borated water.

Table 2.3.4-2, Main Steam Supply System (page 2.3-90), is revised as follows (deleted text with strikethrough and new text is underlined).

Table 2.3.4-2 Main Steam Supply System Component Type Intended Function Closure Bolting Leakage Boundary (spatial)

Pressure Boundary Structural Integrity (attached)

Flow Orifice Leakage Boundary (spatial)

Insulation Insulate (Mechanical)

Piping Leakage Boundary (spatial)

Pressure Boundary Structural Integrity (attached)

Pump Leakage Boundary (spatial)

Silencer Leakage Boundary (spatial)

Structural Integrity (attached)

Strainer Leakage Boundary (spatial)

Tank Leakage Boundary (spatial)

Structural Integrity (attached)

Trap Leakage Boundary (spatial)

Structural Integrity (attached)

Tubing Leakage Boundary (spatial)

Pressure Boundary Valve Filter, Leakage Boundary (spatial)

Pressure Boundary Pressure Relief Structural Integrity (attached)

Section 3.4.2.1.2, Main Steam Supply System (page 3.4-3), is revised as follows (deleted text with strikethrough and new text is underlined).

Environment The main steam supply system components are exposed to the following environments:

Atmosphere/ Weather Borated Water Leakage Condensation Demineralized Water Dry Gas Plant Indoor Air Secondary Water Steam Aging Management Programs The following aging management programs manage the aging effects for the main steam supply system component types:

Bolting Integrity (B2.1.8)

Boric Acid Corrosion (B2.1.4)

External Surfaces Monitoring of Mechanical Components (B2.1.21)

Flow-Accelerated Corrosion (B2.1.7)

Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components (B2.1.23)

One-Time Inspection (B2.1.18)

Water Chemistry (B2.1.2)

Section 3.4.2.1.3, Main Feedwater System (page 3.4-4), is revised as follows (deleted text with strikethrough and new text is underlined).

Environment The main feedwater system components are exposed to the following environments:

Borated Water Leakage Condensation Plant Indoor Air Secondary Water

Aging Management Programs The following aging management programs manage the aging effects for the main feedwater system component types:

Bolting Integrity (B2.1.8)

Boric Acid Corrosion (B2.1.4)

External Surfaces Monitoring of Mechanical Components (B2.1.21)

Flow-Accelerated Corrosion (B2.1.7)

Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components (B2.1.23)

One-Time Inspection (B2.1.18)

Water Chemistry (B2.1.2)

Section 3.4.2.1.4, Steam Generator Blowdown System (page 3.4-5), is revised as follows (deleted text with strikethrough and new text is underlined).

Environment The steam generator blowdown system components are exposed to the following environments:

Borated Water Leakage Condensation Dry Gas Plant Indoor Air Secondary Water Steam Aging Management Programs The following aging management programs manage the aging effects for the steam generator blowdown system component types:

Bolting Integrity (B2.1.8)

Boric Acid Corrosion (B2.1.4)

External Surfaces Monitoring of Mechanical Components (B2.1.21)

Flow-Accelerated Corrosion (B2.1.7)

Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components (B2.1.23)

One-Time Inspection (B2.1.18)

Water Chemistry (B2.1.2)

Section 3.4.2.1.5, Auxiliary Feedwater System (page 3.4-6), is revised as follows (deleted text with strikethrough and new text is underlined).

Environment The auxiliary feedwater system components are exposed to the following environments:

Atmosphere/ Weather Borated Water Leakage Buried Condensation Lubricating Oil Plant Indoor Air Secondary Water Steam Aging Management Programs The following aging management programs manage the aging effects for the auxiliary feedwater system component types:

Bolting Integrity (B2.1.8)

Boric Acid Corrosion (B2.1.4)

Buried and Underground Piping and Tanks (B2.1.25)

External Surfaces Monitoring of Mechanical Components (B2.1.21)

Flow-Accelerated Corrosion (B2.1.7)

Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components (B2.1.23)

Lubricating Oil Analysis (B2.1.24)

One-Time Inspection (B2.1.18)

Water Chemistry (B2.1.2)

Section 3.4.2.1.6, Condensate Storage and Transfer System (page 3.4-8), is revised as follows (deleted text with strikethrough and new text is underlined).

Environment The condensate storage and transfer system components are exposed to the following environments:

Atmosphere/ Weather Borated Water Leakage Concrete

Condensation Dry Gas Plant Indoor Air Secondary Water Aging Management Programs The following aging management programs manage the aging effects for the condensate storage and transfer system component types:

Aboveground Metallic Tanks (B2.1.15)

Bolting Integrity (B2.1.8)

Boric Acid Corrosion (B2.1.4)

External Surfaces Monitoring of Mechanical Components (B2.1.21)

Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components (B2.1.23)

One-Time Inspection (B2.1.18)

Water Chemistry (B2.1.2)

Table 3.4-1, Summary of Aging Management Programs in Chapter VIII of NUREG-1801 for Steam and Power Conversion System (page 3.4-12), is revised as follows (deleted text shown with strikethrough and new text is underlined).

Table 3.4-1 Summary of Aging Management Programs in Chapter VIII of NUREG-1801 for Steam and Power Conversion System Item Number Component Type Aging Effect / Mechanism Aging Management Program Further Evaluation Recommended Discussion 3.4.1.004 Steel External surfaces, Bolting exposed to Air with borated water leakage Loss of material due to boric acid corrosion Boric Acid Corrosion (B2.1.4)

No Not applicable. Callaway has no in-scope components exposed to borated water leakage in the steam and power conversion systems, so the applicable NUREG-1801 lines were not used.

Consistent with NUREG-1801.

Table 3.4.2-2, Steam and Power Conversion System - Summary of Aging Management Evaluation - Main Steam Supply System (page 3.4-34), is revised as follows (deleted text shown with strikethrough and new text is underlined).

Table 3.4.2-2 Steam and Power Conversion System - Summary of Aging Management Evaluation - Main Steam Supply System Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Program NUREG-1801 Item Table 1 Item Notes Closure Bolting LBS, PB, SIA Carbon Steel Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

VIII.H.S-40 3.4.1.004 A

Insulation INS Aluminum Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

VII.E1.AP-1 3.3.1.009 C

Piping LBS, PB, SIA Carbon Steel Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

VIII.H.S-30 3.4.1.004 A

Piping LBS Carbon Steel Demineralized Water (Int)

Loss of material Water Chemistry (B2.1.2) and One-Time Inspection (B2.1.18)

VIII.B1.SP-74 3.4.1.013 A

Table 3.4.2-2 Steam and Power Conversion System - Summary of Aging Management Evaluation - Main Steam Supply System Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Program NUREG-1801 Item Table 1 Item Notes Piping PB Carbon Steel Dry Gas (Int)

None None VIII.I.SP-4 3.4.1.059 A

Pump LBS Carbon Steel Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

VIII.H.S-30 3.4.1.004 A

Tank LBS Carbon Steel Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

VIII.H.S-30 3.4.1.004 A

Tank LBS, SIA Carbon Steel Condensation (Int)

Loss of material Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components (B2.1.23)

VIII.B1.SP-60 3.4.1.037 D

Tank SIA Carbon Steel Plant Indoor Air (Ext)

Loss of material External Surfaces Monitoring of Mechanical Components (B2.1.21)

VIII.H.S-29 3.4.1.034 C

Table 3.4.2-3, Steam and Power Conversion System - Summary of Aging Management Evaluation - Main Feedwater System (page 3.4-41), is revised as follows (deleted text shown with strikethrough and new text is underlined).

Table 3.4.2-3 Steam and Power Conversion System - Summary of Aging Management Evaluation - Main Feedwater System Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Program NUREG-1801 Item Table 1 Item Notes Closure Bolting LBS, PB, SIA Carbon Steel Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

VIII.H.S-40 3.4.1.004 A

Insulation INS Aluminum Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

VII.E1.AP-1 3.3.1.009 C

Piping LBS, PB, SIA Carbon Steel Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

VIII.H.S-30 3.4.1.004 A

Table 3.4.2-4, Steam and Power Conversion System - Summary of Aging Management Evaluation - Steam Generator Blowdown System (page 3.4-47), is revised as follows (deleted text shown with strikethrough and new text is underlined).

Table 3.4.2-4 Steam and Power Conversion System - Summary of Aging Management Evaluation - Steam Generator Blowdown System Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Program NUREG-1801 Item Table 1 Item Notes Closure Bolting LBS, PB Carbon Steel Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

VIII.H.S-40 3.4.1.004 A

Piping LBS, PB, SIA Carbon Steel Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

VIII.H.S-30 3.4.1.004 A

Piping PB Carbon Steel Dry Gas (Int)

None None VIII.I.SP-4 3.4.1.059 A

Table 3.4.2-5, Steam and Power Conversion System - Summary of Aging Management Evaluation - Auxiliary Feedwater System (page 3.4-51), is revised as follows (deleted text shown with strikethrough and new text is underlined).

Table 3.4.2-5 Steam and Power Conversion System - Summary of Aging Management Evaluation - Auxiliary Feedwater System Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Program NUREG-1801 Item Table 1 Item Notes Closure Bolting LBS, PB, SIA Carbon Steel Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

VIII.H.S-40 3.4.1.004 A

Insulation INS Aluminum Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

VII.E1.AP-1 3.4.1.009 C

Piping LBS, PB, SIA Carbon Steel Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

VIII.H.S-30 3.4.1.004 A

Table 3.4.2-5 Steam and Power Conversion System - Summary of Aging Management Evaluation - Auxiliary Feedwater System Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Program NUREG-1801 Item Table 1 Item Notes Piping PB, LBS, SIA Carbon Steel Condensation (Int)

Loss of material Inspection of Internal Surfaces in Miscellaneous Piping and Ducting Components (B2.1.23)

VIII.G.SP-60 3.4.1.037 B

Table 3.4.2-6, Steam and Power Conversion System - Summary of Aging Management Evaluation - Condensate Storage and Transfer System (page 3.4-61), is revised as follows (deleted text shown with strikethrough and new text is underlined).

Table 3.4.2-6 Steam and Power Conversion System - Summary of Aging Management Evaluation - Condensate Storage and Transfer System Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Program NUREG-1801 Item Table 1 Item Notes Closure Bolting PB Carbon Steel Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

VIII.H.S-40 3.4.1.004 A

Piping LBS, PB, SIA Carbon Steel Borated Water Leakage (Ext)

Loss of material Boric Acid Corrosion (B2.1.4)

VIII.H.S-30 3.4.1.004 A