Letter Sequence RAI |
|---|
|
Results
Other: ML11255A032, ML11258A109, ML11342A205, ML12018A332, ML12115A281, ML12118A540, ML12139A066, ML12139A071, ML12139A074, ML12160A012, ML12164A800, ML12256A929, ML12286A325, ML13053A374, ML13171A064, ML14071A378, ML14073A117, RS-14-319, Cancellation of Parent Company Guarantee
|
MONTHYEARML11179A0962011-06-22022 June 2011 Application for Renewed Operating Licenses Project stage: Request ML11209B7092011-07-22022 July 2011 Submittal of Summary Report for Inservice Inspections (2R11) Project stage: Request ML11255A0322011-09-15015 September 2011 Plan for the Scoping and Screening Regulatory Audit Regarding the Limerick Generating Station, Units 1 and 2 License Renewal Application Review Project stage: Other ML11258A1092011-09-20020 September 2011 Plan for the Aging Management Program Regulatory Audit Regarding the Limerick Generating Station, Units 1 and 2 License Renewal Application Review Project stage: Other ML1134101442011-12-0707 December 2011 Response to NRC Request for Additional Information, Dated November 18, 2011 Project stage: Response to RAI ML11342A2052011-12-0909 December 2011 Scoping and Screening Methodology Audit Report Regarding the Limerick Generating Station, Units 1 and 2 Project stage: Other ML1133402312011-12-12012 December 2011 Request for Additional Information for Limerick Generating Station, Units 1 and 2 License Renewal Application-Scoping and Screening Project stage: RAI ML11343A4382011-12-15015 December 2011 Requests for Additional Information for the Review of the Limerick Generating Station License Renewal Application Project stage: RAI ML11335A3172012-01-0505 January 2012 RAI for the Review of the Limerick Generating Station License Renewal Application Project stage: RAI ML11347A3602012-01-17017 January 2012 Requests for Additional Information for the Review of the Limerick Generating Station License Renewal Application Project stage: RAI ML11361A0832012-01-18018 January 2012 Requests for Additional Information for the Review of the Limerick Generating Station, Units 1 and 2, License Renewal Application Project stage: RAI ML11361A0792012-01-24024 January 2012 Requests for Additional Information for the Review of the Limerick Generating Station, Units 1 and 2, License Renewal Application Project stage: RAI ML12027A2282012-01-27027 January 2012 Response to NRC Request for Information, Dated January 5, 2012, Related to License Renewal Application Project stage: Response to RAI ML11364A0992012-01-30030 January 2012 Requests for Additional Information for the Review of the Limerick Generating Station, Units 1 and 2, License Renewal Application Project stage: RAI ML12163A7532012-01-31031 January 2012 Lr - FW: Request for Additional Information for the Review of the Limerick Generation Station, Units 1 and 2 License Renewal Application Project stage: Request ML12005A2512012-01-31031 January 2012 Request for Additional Information for the Review of the Limerick Generating Station Units 1 and 2 License Renewal Application (TAC Nos. ME6555, ME6556) TLAA 43 and 468 RAIs Project stage: RAI ML12018A0332012-02-14014 February 2012 Request for Additional Information for the Review of the Limerick Generating Station, Units 1 and 2, License Renewal Application (TAC Nos. ME6555, ME6556) Rapb AMR2 RAIs Project stage: RAI ML1204700842012-02-15015 February 2012 Response to NRC RAI Dated Jan. 17, 2012 Re. Limerick Gen. Station LRA Project stage: Request ML12017A1592012-02-16016 February 2012 Request for Additional Information for the Review of the Limerick Generating Station, Units 1 and 2, License Renewal Application Project stage: RAI ML12024A2312012-02-16016 February 2012 Requests for Additional Information for the Review of the Limerick Generating Station, Units 1 and 2, License Renewal Application (TAC Nos. ME6555 and ME6556) OE and Other RAIs Project stage: RAI ML1204703722012-02-16016 February 2012 Response to NRC Request for Additional Information, Dated January 17, 2012 Project stage: Response to RAI ML12019A1562012-02-17017 February 2012 Requests for Additional Information for the Review of the Limerick Generating Station, Units 1 and 2, License Renewal Application Project stage: RAI ML12018A0352012-02-23023 February 2012 Requests for Addtional Information for the Review of the Limerick Generating Station, Units 1 & 2, License Renewal Application Project stage: Approval ML12059A3452012-02-28028 February 2012 Response to NRC Request for Additional Information, Dated January 30, 2012, Related to License Renewal Application Project stage: Response to RAI ML12018A3322012-02-28028 February 2012 Letter Aging Management Programs Audit Report Regarding the Limerick Generating Station, Units 1 and 2 (TAC NO.ME6555 & ME6556) Project stage: Other ML12060A1542012-02-29029 February 2012 Response to NRC Request for Additional Information, Dated January 31, 2012 Related to License Renewal Application Project stage: Response to RAI ML12065A2062012-03-0505 March 2012 Response to NRC Requests for Additional Information, Dated February 16, 2012, and February 17, 2012, Related to Renewal Application Project stage: Response to RAI ML12009A1352012-03-0909 March 2012 Summary of the Telephone Conference Call Held on December 14, 2011, Between the U.S. Nuclear Regulatory Commission and Exelon on Generation Company, LLC, Concerning Requests for Additional Information Pertaining to the Limerick 12-14-11 Tel Project stage: RAI ML12046A8992012-03-0909 March 2012 Request for Additional Information for the Review of the Limerick Generating Station, Units 1 and 2, License Renewal Application (TAC Nos. ME6555 and ME6556) Limerick App J RAIs Project stage: RAI ML1207303612012-03-13013 March 2012 Response to NRC Requests for Additional Information, Dated February 14 and February 16, 2012, Related to the Limerick Generating Station License Renewal Application Project stage: Response to RAI ML12080A1182012-03-20020 March 2012 Response to NRC Requests for Additional Information, Dated February 23 and March 9, 2012, Related to License Renewal Application Project stage: Response to RAI ML12074A0372012-03-22022 March 2012 Letter Request for Additional Information for the Review of the Limerick Generating Station, Units 1 and 2, License Renewal Application (TAC Nos. ME6555, ME6556) Buried Piping and FP Follow Up Project stage: RAI ML12090A4892012-03-30030 March 2012 Response to NRC Request for Additional Information, Dated March 22, 2012 and Information Addressing Minor Errors or Omissions Related to License Renewal Application Project stage: Response to RAI ML12080A1902012-04-0505 April 2012 Request for Additional Information for the Review of the Limerick Generating Station, Units 1 and 2, License Renewal Application (TAC Nos. ME6555 and ME6556) BWR SCC SMP and Ctws Follow Up Project stage: RAI ML12066A0262012-04-0909 April 2012 February 9, 2012, Summary of Telephone Conference Call Held Between the U.S. Nuclear Regulatory Commission and Exelon Generation Company, Llc. Concerning Request for Additional Information Pertaining to the Limerick Project stage: RAI ML12104A1182012-04-13013 April 2012 Response to NRC Requests for Additional Information, Dated April 5, 2012, Related to License Renewal Application Project stage: Response to RAI ML12089A3772012-04-13013 April 2012 Request for Additional Information for the Review of the Limerick Generating Station, Units 1 and 2, License Renewal Application (TAC Nos. ME6556 and ME6555) Fluence and FP Followup RAIs Project stage: RAI ML12082A1552012-04-16016 April 2012 Requests for Additional Information for the Review of the Limerick Generating Station, Units 1 and 2, License Renewal Application Project stage: RAI ML12095A3982012-04-17017 April 2012 Request for Additional Information for the Review of the Limerick Generating Station, Units 1 and 2, License Renewal Application (TAC Nos ME6555 and ME6556)TLAA Follow-up RAIs Project stage: RAI ML12025A0512012-04-20020 April 2012 Summary of Telephone Conference Call Held on January 18, 2012, Between the U.S. Nuclear Regulatory Commission and Exelon Generation Company, LLC, Concerning Request for Additional Information Pertaining to the Limerick Generation 1-18-12 Te Project stage: RAI ML12059A0802012-04-20020 April 2012 February 17, 2012, Summary of Telephone Conference Call Held Between U.S. Nuclear Regulatory Commission and Exelon Generation Company, LLC, Concerning Request for Additional Information Pertaining to the Limerick 2-17-12 Telecon Summary Project stage: RAI ML12018A0232012-04-26026 April 2012 1/12/2012 Telecon Summary Between the U.S. Nuclear Regulatory Commission and Exelon Generation Company, LLC, Concerning Requests for Additional Information Pertaining to the Limerick Generating Station, License Renewal Application Project stage: RAI ML12118A5402012-04-27027 April 2012 Notices of Appearance of Paul M. Bessette and Stephen J. Burdick Project stage: Other ML12111A0342012-04-30030 April 2012 Request for Additional Information for the Review of the Limerick Generating Station, Units 1 and 2, License Renewal Application (TAC Nos. ME6555 and ME6556)SCC RAIs Project stage: RAI ML12047A1242012-05-0101 May 2012 Summary of Telephone Conference Call Held Between NRC and Exelon Generation Co., LLC, Concerning Requests for Additional Information Pertaining to the Limerick, License Renewal Application Project stage: RAI ML12125A3342012-05-0404 May 2012 Responses to NRC Requests for Additional Information, Dated April 17, 2012, Related to the License Renewal Application Project stage: Response to RAI ML12128A4382012-05-0707 May 2012 Responses to NRC Requests for Additional Information, Dated April 30, 2012, Related to the License Renewal Application Project stage: Response to RAI ML12123A0922012-05-18018 May 2012 RAI for Review of the Limerick Generation Station, Units 1 & 2 & License Renewal Application Project stage: RAI ML12136A0362012-05-18018 May 2012 Request for Additional Information for the Review of the Limerick Generating Station, Units 1 and 2, (TAC Nos. ME6555 and ME6556)Scoping Drawings Followup RAI Project stage: RAI ML12115A2812012-05-24024 May 2012 4-17-12 Telecon Summary Project stage: Other 2012-02-28
[Table View] |
Text
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 April 17, 2012 Mr. Michael P. Gallagher Vice President, liCense Renewal Projects Exelon Generation Company, LLC 200 Exelon Way Kennett Square, PA 19348
SUBJECT:
REQUESTS FOR ADDITIONAL INFORMATION FOR THE REVIEW OF THE LIMERICK GENERATING STATION, UNITS 1 AND 2, LICENSE RENEWAL APPLICATION (TAC NOS. ME6555 AND ME6556)
Dear Mr. Gallagher:
By letter dated June 22, 2011, Exelon Generation Company, LLC submitted an application pursuant to Title 10 of the Code of Federal Regulations, Part 54, to renew the operating licenses for Limerick Generating Station, Units 1 and 2, for review by the U.S. Nuclear Regulatory Commission (NRC or the staff). The staff is reviewing the information contained in the license renewal application and has identified, in the enclosure, areas where additional information is needed to complete the review.
These requests for additional information (RAls) were discussed with Christopher Wilson, and a mutually agreeable date for the response is within 30 days from the date of this letter. If you have any questions, please contact me by telephone at 301-415-3733 or bye-mail at Robert. Kuntz@nrc.gov.
Sincerely, ntz, Senior Project Manager Projects Branch 1 Division of License Renewal Office of Nuclear Reactor Regulation Docket Nos. 50-352 and 50-353
Enclosure:
Requests for Additional Information cc w/encl: Listserv
LIMERICK GENERATING STATION LICENSE RENEWAL APPLICATION REQUESTS FOR ADDITIONAL INFORMATION RAI4.1-1.1
Background
Updated Final Safety Analysis Report (UFSAR) Section 3.9.1.1.8 was referenced in the response to RAI 4.1-1. UFSAR Section 3.9.1.1.8 contains a listing of transients in the main steam isolation valve (MSIV) fatigue analysis. One of these transients included in this section is "Preop @ 100 F/hr" with a limit of 150 cycles.
The staff noted that the "Preop @ 100 F/hr" transient was not included in LRA Tables 4.3.1-1 and 4.3.1-2; therefore, it is not clear to the staff whether this transient is monitored, needs to be monitored or will be monitored during the period of extended operation.
Request Clarify if this transient, "Preop @ 100 F/hr," is associated with a transient that is already monitored by the Fatigue Monitoring Program. If not, justify why this transient does not need to be monitored by the Fatigue Monitoring Program.
RAI4.3-S.1
Background
The response to RAI 4.3-6, in letter dated February 29, 2012, discusses the environmental assisted fatigue evaluation for American Society of Mechanical Engineers (ASME) Code Class 1 valves. The applicant's results of the analyzed ASME Code Class 1 valves from this evaluation were also provided as part of the response.
LRA Sections 4.3.3 and A.4.3.3 were not updated to include the results and description of the evaluation of environmentally assisted fatigue for ASME Code Class 1 valves. Therefore, it is not clear whether these environmental assisted fatigue evaluations are included as part of the 10 CFR 54.21 (c)(1 )(iii) disposition and are part of the Fatigue Monitoring Program.
Request Confirm that the environmental assisted fatigue analyses for ASME Code Class I valves are managed by the Fatigue Monitoring program and are included in the disposition in accordance with 10 CFR 54.21 (c)(1)(iii) in LRA Section 4.3.3 and A.4.3.3.
- 2 If not, justify that LRA Sections 4.3.3 and A.4.3.3 do not need to be updated to include information associated with the environmentally assisted fatigue evaluations for ASME Code.
Class 1 valves and that they are also managed by the Fatigue Monitoring Program for environmentally assisted fatigue.
RAI4.3-S.2
Background
Page 15 of 30 in response to RAI4.3-6, in letter dated February 29,2012, it states "[t]he RHR shutdown cooling system valves are exposed to transients associated with shutdown cooling operations that are not experienced by the RHR LPCI and core spray injection valves. The RHR LPCI and core spray injection valves are only exposed to transients that are also experienced by the RHR shutdown cooling return valves."
It is not clear what transients are experienced by the RHR SOC valves and by the RHR LPCI and core spray injection valves.
Request Confirm that statements 1 and 2 are true:
- 1) RHR SOC valves experience: (transients associated with shutdown cooling operations)
+ (transients X, Y, Z... )
- 2) RHR LPCI and core spray injection valves experience: (transients X, Y, Z... )
AND RHR LPCI and core spray injection valves 00 NOT experience: (transients associated with shutdown cooling operations)
If both statements are not true, clarify what transients are experienced by the RHR SOC valves and by the RHR LPCI and core spray injection valves.
RAI4.3-9.1 Background and issue The response to RAI 4.3-9 (Part 1), provided by letter dated February 29, 2012, stated that the revised environmental fatigue analysis evaluates the inside surface location at the clad/base metal interface directly below the limiting outside surface location. This location was selected to represent the wetted internal surface of the forging but takes no credit for the presence of the cladding. Since this location was not originally analyzed for metal fatigue, no ASME Code cumulative usage factor (CUF) value is reported. However, the response revised Table 4.3.3-1 for the ASME Code CUF value for Core Spray Nozzle (Forging) from 0.097 to 0.0016. The response does not explain what the value of 0.0016 represents since the response indicated that no ASME Code CUF value is reported for this location.
- 3 The staff also noted that for the core spray piping in Tables 4.3.3-2, the difference in Fen values between Limerick Generation Station (LGS), Units 1 and 2 is substantial. The staff recognized that different nodes are reported. However, the response did not explain the difference in Fen.
Request
- 1. Explain the ASME Code CUF value of 0.0016 for Core Spray Nozzle (Forging) in Table 4.3.3-1.
- 2. Explain why the Fen values for the core spray piping are different between LGS, Units 1 and
- 2.
RAI4.3-10.1 Background and issue The response to RAI 4.3-10, provided by letter dated February 29, 2012, provided the CUF values for a list of components that have been analyzed for fatigue. The response indicated that the steam dryer, steam dryer support brackets, and control rod guide tube are "exempt."
The response did not explain why these three components are exempted in the fatigue analysis.
Request Clarify why these three components are exempted. As part of the clarification, if applicable, identify the provisions in the ASME Code Section III that allowed the exemption of the required fatigue analysis for these components.
Letter to M. Gallagher from R. Kuntz dated April 17, 2012
SUBJECT:
REQUESTS FOR ADDITIONAL INFORMATION FOR THE REVIEW OF THE LIMERICK GENERATING STATION, UNITS 1 AND 2, LICENSE RENEWAL APPLICATION (TAC NOS. ME6555 AND ME6556)
DISTRIBUTION:
HARDCOPY:
DLRRF E-MAIL:
PUBLIC RidsNrrDlr Resource RidsNrrDlrRpb1 Resource RidsNrrDlrRpb2 Resource RidsNrrDlrRerb Resource RidsNrrDlrRarb Resource RidsNrrDlrRasb Resource RidsNrrDlrRapb Resource RidsNrrDlrRpob Resource RidsNrrPMLimerick Resource RidsOgcMailCenter Resource RKuntz DMorey LPerkins MSmith,OGC RConte, RI MModes, RI GDiPaolo, RI NSieller, RI
'.. ML12095a398 OFFICE LA:RPB1:DLR PM:RPB1 :DLR BC:RPB1 :DLR PM: RPB1 :DLR NAME YEdmonds RKuntz DMorey RKuntz DATE 4/12/12 4/12/12 4/12/12 41 17 112