Letter Sequence Request |
|---|
|
Results
Other: ML11255A032, ML11258A109, ML11342A205, ML12018A332, ML12115A281, ML12118A540, ML12139A066, ML12139A071, ML12139A074, ML12160A012, ML12164A800, ML12256A929, ML12286A325, ML13053A374, ML13171A064, ML14071A378, ML14073A117, RS-14-319, Cancellation of Parent Company Guarantee
|
MONTHYEARML11179A0962011-06-22022 June 2011 Application for Renewed Operating Licenses Project stage: Request ML11209B7092011-07-22022 July 2011 Submittal of Summary Report for Inservice Inspections (2R11) Project stage: Request ML11255A0322011-09-15015 September 2011 Plan for the Scoping and Screening Regulatory Audit Regarding the Limerick Generating Station, Units 1 and 2 License Renewal Application Review Project stage: Other ML11258A1092011-09-20020 September 2011 Plan for the Aging Management Program Regulatory Audit Regarding the Limerick Generating Station, Units 1 and 2 License Renewal Application Review Project stage: Other ML1134101442011-12-0707 December 2011 Response to NRC Request for Additional Information, Dated November 18, 2011 Project stage: Response to RAI ML11342A2052011-12-0909 December 2011 Scoping and Screening Methodology Audit Report Regarding the Limerick Generating Station, Units 1 and 2 Project stage: Other ML1133402312011-12-12012 December 2011 Request for Additional Information for Limerick Generating Station, Units 1 and 2 License Renewal Application-Scoping and Screening Project stage: RAI ML11343A4382011-12-15015 December 2011 Requests for Additional Information for the Review of the Limerick Generating Station License Renewal Application Project stage: RAI ML11335A3172012-01-0505 January 2012 RAI for the Review of the Limerick Generating Station License Renewal Application Project stage: RAI ML11347A3602012-01-17017 January 2012 Requests for Additional Information for the Review of the Limerick Generating Station License Renewal Application Project stage: RAI ML11361A0832012-01-18018 January 2012 Requests for Additional Information for the Review of the Limerick Generating Station, Units 1 and 2, License Renewal Application Project stage: RAI ML11361A0792012-01-24024 January 2012 Requests for Additional Information for the Review of the Limerick Generating Station, Units 1 and 2, License Renewal Application Project stage: RAI ML12027A2282012-01-27027 January 2012 Response to NRC Request for Information, Dated January 5, 2012, Related to License Renewal Application Project stage: Response to RAI ML11364A0992012-01-30030 January 2012 Requests for Additional Information for the Review of the Limerick Generating Station, Units 1 and 2, License Renewal Application Project stage: RAI ML12163A7532012-01-31031 January 2012 Lr - FW: Request for Additional Information for the Review of the Limerick Generation Station, Units 1 and 2 License Renewal Application Project stage: Request ML12005A2512012-01-31031 January 2012 Request for Additional Information for the Review of the Limerick Generating Station Units 1 and 2 License Renewal Application (TAC Nos. ME6555, ME6556) TLAA 43 and 468 RAIs Project stage: RAI ML12018A0332012-02-14014 February 2012 Request for Additional Information for the Review of the Limerick Generating Station, Units 1 and 2, License Renewal Application (TAC Nos. ME6555, ME6556) Rapb AMR2 RAIs Project stage: RAI ML1204700842012-02-15015 February 2012 Response to NRC RAI Dated Jan. 17, 2012 Re. Limerick Gen. Station LRA Project stage: Request ML12017A1592012-02-16016 February 2012 Request for Additional Information for the Review of the Limerick Generating Station, Units 1 and 2, License Renewal Application Project stage: RAI ML12024A2312012-02-16016 February 2012 Requests for Additional Information for the Review of the Limerick Generating Station, Units 1 and 2, License Renewal Application (TAC Nos. ME6555 and ME6556) OE and Other RAIs Project stage: RAI ML1204703722012-02-16016 February 2012 Response to NRC Request for Additional Information, Dated January 17, 2012 Project stage: Response to RAI ML12019A1562012-02-17017 February 2012 Requests for Additional Information for the Review of the Limerick Generating Station, Units 1 and 2, License Renewal Application Project stage: RAI ML12018A0352012-02-23023 February 2012 Requests for Addtional Information for the Review of the Limerick Generating Station, Units 1 & 2, License Renewal Application Project stage: Approval ML12059A3452012-02-28028 February 2012 Response to NRC Request for Additional Information, Dated January 30, 2012, Related to License Renewal Application Project stage: Response to RAI ML12018A3322012-02-28028 February 2012 Letter Aging Management Programs Audit Report Regarding the Limerick Generating Station, Units 1 and 2 (TAC NO.ME6555 & ME6556) Project stage: Other ML12060A1542012-02-29029 February 2012 Response to NRC Request for Additional Information, Dated January 31, 2012 Related to License Renewal Application Project stage: Response to RAI ML12065A2062012-03-0505 March 2012 Response to NRC Requests for Additional Information, Dated February 16, 2012, and February 17, 2012, Related to Renewal Application Project stage: Response to RAI ML12009A1352012-03-0909 March 2012 Summary of the Telephone Conference Call Held on December 14, 2011, Between the U.S. Nuclear Regulatory Commission and Exelon on Generation Company, LLC, Concerning Requests for Additional Information Pertaining to the Limerick 12-14-11 Tel Project stage: RAI ML12046A8992012-03-0909 March 2012 Request for Additional Information for the Review of the Limerick Generating Station, Units 1 and 2, License Renewal Application (TAC Nos. ME6555 and ME6556) Limerick App J RAIs Project stage: RAI ML1207303612012-03-13013 March 2012 Response to NRC Requests for Additional Information, Dated February 14 and February 16, 2012, Related to the Limerick Generating Station License Renewal Application Project stage: Response to RAI ML12080A1182012-03-20020 March 2012 Response to NRC Requests for Additional Information, Dated February 23 and March 9, 2012, Related to License Renewal Application Project stage: Response to RAI ML12074A0372012-03-22022 March 2012 Letter Request for Additional Information for the Review of the Limerick Generating Station, Units 1 and 2, License Renewal Application (TAC Nos. ME6555, ME6556) Buried Piping and FP Follow Up Project stage: RAI ML12090A4892012-03-30030 March 2012 Response to NRC Request for Additional Information, Dated March 22, 2012 and Information Addressing Minor Errors or Omissions Related to License Renewal Application Project stage: Response to RAI ML12080A1902012-04-0505 April 2012 Request for Additional Information for the Review of the Limerick Generating Station, Units 1 and 2, License Renewal Application (TAC Nos. ME6555 and ME6556) BWR SCC SMP and Ctws Follow Up Project stage: RAI ML12066A0262012-04-0909 April 2012 February 9, 2012, Summary of Telephone Conference Call Held Between the U.S. Nuclear Regulatory Commission and Exelon Generation Company, Llc. Concerning Request for Additional Information Pertaining to the Limerick Project stage: RAI ML12104A1182012-04-13013 April 2012 Response to NRC Requests for Additional Information, Dated April 5, 2012, Related to License Renewal Application Project stage: Response to RAI ML12089A3772012-04-13013 April 2012 Request for Additional Information for the Review of the Limerick Generating Station, Units 1 and 2, License Renewal Application (TAC Nos. ME6556 and ME6555) Fluence and FP Followup RAIs Project stage: RAI ML12082A1552012-04-16016 April 2012 Requests for Additional Information for the Review of the Limerick Generating Station, Units 1 and 2, License Renewal Application Project stage: RAI ML12095A3982012-04-17017 April 2012 Request for Additional Information for the Review of the Limerick Generating Station, Units 1 and 2, License Renewal Application (TAC Nos ME6555 and ME6556)TLAA Follow-up RAIs Project stage: RAI ML12025A0512012-04-20020 April 2012 Summary of Telephone Conference Call Held on January 18, 2012, Between the U.S. Nuclear Regulatory Commission and Exelon Generation Company, LLC, Concerning Request for Additional Information Pertaining to the Limerick Generation 1-18-12 Te Project stage: RAI ML12059A0802012-04-20020 April 2012 February 17, 2012, Summary of Telephone Conference Call Held Between U.S. Nuclear Regulatory Commission and Exelon Generation Company, LLC, Concerning Request for Additional Information Pertaining to the Limerick 2-17-12 Telecon Summary Project stage: RAI ML12018A0232012-04-26026 April 2012 1/12/2012 Telecon Summary Between the U.S. Nuclear Regulatory Commission and Exelon Generation Company, LLC, Concerning Requests for Additional Information Pertaining to the Limerick Generating Station, License Renewal Application Project stage: RAI ML12118A5402012-04-27027 April 2012 Notices of Appearance of Paul M. Bessette and Stephen J. Burdick Project stage: Other ML12111A0342012-04-30030 April 2012 Request for Additional Information for the Review of the Limerick Generating Station, Units 1 and 2, License Renewal Application (TAC Nos. ME6555 and ME6556)SCC RAIs Project stage: RAI ML12047A1242012-05-0101 May 2012 Summary of Telephone Conference Call Held Between NRC and Exelon Generation Co., LLC, Concerning Requests for Additional Information Pertaining to the Limerick, License Renewal Application Project stage: RAI ML12125A3342012-05-0404 May 2012 Responses to NRC Requests for Additional Information, Dated April 17, 2012, Related to the License Renewal Application Project stage: Response to RAI ML12128A4382012-05-0707 May 2012 Responses to NRC Requests for Additional Information, Dated April 30, 2012, Related to the License Renewal Application Project stage: Response to RAI ML12123A0922012-05-18018 May 2012 RAI for Review of the Limerick Generation Station, Units 1 & 2 & License Renewal Application Project stage: RAI ML12136A0362012-05-18018 May 2012 Request for Additional Information for the Review of the Limerick Generating Station, Units 1 and 2, (TAC Nos. ME6555 and ME6556)Scoping Drawings Followup RAI Project stage: RAI ML12115A2812012-05-24024 May 2012 4-17-12 Telecon Summary Project stage: Other 2012-02-28
[Table View] |
Text
1 LimerickNPEm Resource From:
Christopher.Wilson2@exeloncorp.com Sent:
Tuesday, July 10, 2012 4:19 PM To:
Kuntz, Robert
Subject:
FW: LIMERICK: Request for Additional information for the Review of the Limerick Generating Station, Units 1 and 2, License Renewal Application (TAC Nos. ME6555 and ME6566)
Attachments:
ML12181A441.pdf Robthe first RAI is titled DRAFT RAI 4.1-3 From: NRC_MAIL_DLR Resource [1]
Sent: Tuesday, July 10, 2012 4:14 PM To: Wilson, Christopher D:(GenCo-Nuc)
Subject:
LIMERICK: Request for Additional information for the Review of the Limerick Generating Station, Units 1 and 2, License Renewal Application (TAC Nos. ME6555 and ME6566)
LIMERICK: Request for Additional information for the Review of the Limerick Generating Station, Units 1 and 2, License Renewal Application (TAC Nos. ME6555 and ME6566)
ADAMS Accession No. ML12181A441 The attached document is being sent to you per your request to receive electronic mailings, if you wish to be removed follow the instructions below. The document is publicly available and will be accessible via the public web site Electronic Reading Room in the Agency Document Access and Management System (ADAMS),
http://www.nrc.gov/reading-rm/adams.html, generally within six days. To access this document use the ADAMS number provided in this email.
Documents containing proprietary or safeguards information are not publicly available and will not be sent using the electronic mailing system.
You are currently subscribed to limerick as: christopher.wilson2@exeloncorp.com.
To unsubscribe: Please go to the NRC's public website http://www.nrc.gov/public-involve/listserver/plants-by-region.html Once at the site, type in your e-mail address in the space provided and check the box(es) that correspond to the list(s) you would like to unsubscribe from. Then click the Unsubscribe button.
or send an email to lyris@nrc.gov with the following information in the subject line unsubscribe limerick christopher.wilson2@exeloncorp.com
- This e-mail and any of its attachments may contain Exelon Corporation proprietary information, which is privileged, confidential, or subject to copyright belonging to the Exelon Corporation family of Companies. This e-mail is intended solely for the use of the individual or entity to which it is addressed. If you are not the intended recipient of this e-mail, you are hereby notified that any dissemination, distribution, copying, or action taken in relation to the contents of and
2 attachments to this e-mail is strictly prohibited and may be unlawful. If you have received this e-mail in error, please notify the sender immediately and permanently delete the original and any copy of this e-mail and any printout. Thank You. **************************************************
Hearing Identifier:
Limerick_LR_NonPublic Email Number:
1319 Mail Envelope Properties (9A15F707EB47A04D882D9FEB352EDDF80408D829)
Subject:
FW: LIMERICK: Request for Additional information for the Review of the Limerick Generating Station, Units 1 and 2, License Renewal Application (TAC Nos. ME6555 and ME6566)
Sent Date:
7/10/2012 4:19:07 PM Received Date:
7/10/2012 4:19:16 PM From:
Christopher.Wilson2@exeloncorp.com Created By:
Christopher.Wilson2@exeloncorp.com Recipients:
"Kuntz, Robert" <Robert.Kuntz@nrc.gov>
Tracking Status: None Post Office:
cccmsxch12.energy.power.corp Files Size Date & Time MESSAGE 2716 7/10/2012 4:19:16 PM ML12181A441.pdf 193124 Options Priority:
Standard Return Notification:
No Reply Requested:
No Sensitivity:
Normal Expiration Date:
Recipients Received: