UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 June 12, 2012 Mr. Michael P. Gallagher Vice President, License Renewal Projects Exelon Generation Company, LLC 200 Exelon Way Kennett Square, PA 19348

SUBJECT:

REQUESTS FOR ADDITIONAL INFORMATION FOR THE REVIEW OF THE LIMERICK GENERATING STATION, UNITS 1 AND 2, LICENSE RENEWAL APPLICATION (TAC NOS. ME6555 AND ME6556)

Dear Mr. Gallagher:

By letter dated June 22, 2011, Exelon Generation Company, LLC submitted an application pursuant to Title 10 of the Code ofFederal Regulations Part 54, to renew the operating licenses for Limerick Generating Station, Units 1 and 2, for review by the U.S. Nuclear Regulatory Commission (NRC or the staff). The staff is reviewing the information contained in the license renewal application and has identified, in the enclosure, areas where additional information is needed to complete the review.

These requests for additional information (RAls) were discussed with Christopher Wilson, and a mutually agreeable date for the response is within 30 days from the date of this letter. If you have any questions, please contact me by telephone at 301-415-3733 or bye-mail at Robert. Kuntz@nrc.gov.

Sincerely, Rob F. KU~ior Project Manager Projects Branch 1 Division of License Renewal Office of Nuclear Reactor Regulation Docket Nos. 50-352 and 50-353

Enclosure:

Requests for Additional Information cc w/encl: Listserv

LIMERICK GENERATING STATION LICENSE RENEWAL APPLICATION REQUESTS FOR ADDITIONAL INFORMATION RAI 3.1.1.38-1.2

Background

RAI 3.1.1.38-1.1 requested justification as to why opportunistic inspections and the planned inspection method would be adequate to manage loss of fracture toughness due to thermal aging embrittlement of the ASME Code Class 3 cast austenitic stainless steel (CASS) pump casings in the reactor water cleanup system (RWCU).

Issue:

The response to RAI 3.1.1.38-1.1, provided by letter dated May 31, 2012, does not address the history and results of the previous VT-3 examinations conducted on the CASS pump casings.

Therefore, the staff needs the following information to further evaluate the adequacy of the opportunistic inspections for managing aging: (1) when the previous VT-3 examinations were conducted on the CASS pump casings, and (2) the results of the inspections.

Request:

1. If any inspections have been performed on the ASME Code Class 3 CASS pump casings, provide the inspection results including when the inspection(s) were completed.
2. Based on the history and results of the previous inspections using the VT-3 examination, justify why the aging management would not need to ensure the following inspections of the RWCU pump casings: (1) an inspection of the representative pump casing of each unit prior to the period of extended operation and (2) at least, an inspection of the representative pump casing of each unit during the period of extended operation.

ENCLOSURE

Letter to M. Gallqgher from R Kuntz dated June 12, 2012

SUBJECT:

REQUESTS FOR ADDITIONAL INFORMATION FOR THE REVIEW OF THE.

LIMERICK GENERATING STATION LICENSE RENEWAL APPLICATION (TAC NOS. ME6555, ME6556)

DISTRIBUTION:

HARDCOPY:

DLR RF E-MAIL:

PUBLIC RidsNrrDlr Resource RidsNrrDlrRpb1 Resource RidsNrrDlrRpb2 Resource RidsNrrDlrRerb Resource RidsNrrDlrRarb Resource RidsNrrDlrRasb Resource RidsNrrDlrRapb Resource RidsNrrDlrRpob Resource RidsNrrPNILimerick Resource RidsOgcMailCenter Resource RKuntz DMorey LPerkins MSmith,OGC RConte, RI MModes, RI GDiPaolo, RI NSielier, RI

'1VIL12160A012 OFFICE LARPB1 :DLR PM:RPB1 :DLR BC:RPB1:DLR PM: RPB1 :DLR I

NAME YEdmonds RKuntz DMorey RKuntz 06/12/12 06/12/12 06/12/12 06/12/12 I