MONTHYEARML11277A2402011-09-21021 September 2011 TAC ME7250 - Public - 7 Pages - Kewaunee Power Station License Amendment Request 250: Adoption of NFPA-805 Performance-based Standard for Fire Protection for Light Water Reactor Electric Generating Plants (2001 Edition) Project stage: Request ML11277A2652011-09-21021 September 2011 TAC ME7250 - Public - 405 Pages - Kewaunee Power Station, Transition to 10 CFR 50.48(c) - NFPA 805 Performance-based Standard for Fire Protection for Light Water Reactor Electric Generating Plants, 2001 Edition Project stage: Other ML1132025922011-12-0101 December 2011 National Fire Protection Association Standard 805 License Amendment Application Online Reference Portal Project stage: Other ML11341A1762011-12-0606 December 2011 NRR E-mail Capture - ME7250 - FW: Call from Kewaunee NFPA 805 Suspension Project stage: Other ML11363A0312011-12-16016 December 2011 Request to Postpone Review of License Amendment Request 250 Adoption of NFPA 805 Performance-Based Standard for Fire Protection for Light Water Reactor Electric Generating Plants (2001 Edition). Project stage: Request ML11355A0742011-12-19019 December 2011 NRR E-mail Capture - ME7250 Kewaunee NFPA-805 LIC-109 Acceptance Review Results Project stage: Acceptance Review ML11353A4122011-12-19019 December 2011 NRR E-mail Capture - ME7250 - Kewaunee NFPA-805 Adoption - Postponement Letter from Licensee Project stage: Other ML1135501612011-12-22022 December 2011 Acceptance Review Associated with Proposed License Amendment Request to Adopt National Fire Protection Standard 805 Project stage: Acceptance Review ML12018A4492012-01-13013 January 2012 NRR E-mail Capture - Kewaunee NFPA-805 Withdraw Letter Project stage: Other ML1202400072012-02-14014 February 2012 Withdrawal of License Amendment Request Project stage: Withdrawal ML12058A5712012-02-24024 February 2012 NRR E-mail Capture - ME7250 - Kewaunee NFPA-805 Withdrawal Acknowledgement Letter - Courtesy Call of 2/16/2012 - Record Project stage: Other 2011-12-06
[Table View] |
|
---|
Category:E-Mail
MONTHYEARML23109A1862023-04-19019 April 2023 and Turkey Point Acceptance of Requested Licensing Action Proposed Alternative to Asme Section XI Authorizing Implementation of Asme Code Case N-752-1 ML22067A0922022-03-0303 March 2022 State Consultation - Duane Arnold ISFSI-Only EP License Amendment ML22040A1162022-02-0808 February 2022 Email to G. Van Noordennen Zion and La Crosse Review Schedule Changes ML22027A3582022-01-26026 January 2022 DAEC: CY2022 Inspection Plan, Docket No: 05000331, License No: DPR-49 ML22007A3102022-01-0505 January 2022 State Consultation - Draft No Significant Hazards Determination Regarding a LAR for NextEra Energy Duane Arnold, LLC, Duane Arnold Energy Center ISFSI in Palo, Iowa ML22005A0862022-01-0404 January 2022 1-4-2022 Email Communication to Duane Arnold Regarding Its ISFSI Related Exemption Request on Supplemental Information Needed ML22005A0992022-01-0404 January 2022 Email from a Snyder to a Leek Re State Consultation - Draft No Significant Hazards Determination - License Amend. Req. for NextEra Energy, LLC, DAEC ISFSI in Palo, Iowa ML22005A1012022-01-0404 January 2022 Email from a Leek to a Snyder Re State Consultation - Draft No Significant Hazards Determination - License Amend. Req. for NextEra Energy, LLC, DAEC ISFSI in Palo Iowa ML22004A0122022-01-0303 January 2022 E-mail from M. Davis, NextEra, to A. Snyder, NRC, - Duane Arnold Energy Center - Supplement Information to Technical Specification Amendment Application ML21354A6722021-12-17017 December 2021 Email to State of Iowa - Draft EA on Duane Arnold Exemption ML21214A0482021-08-0101 August 2021 Acceptance of License Amendment Request to Adopt an ISFSI-Only Emergency Plan ML21214A0502021-08-0101 August 2021 Acceptance of License Amendment Request to Adopt an ISFSI-Only Physical Security Plan ML21165A1212021-06-10010 June 2021 E-mail from M. Davis, Duane Arnold, to M. Doell and R. Edwards, NRC - Duane Arnold Defueled Emergency Plan Implementation Confirmation ML21117A2752021-04-26026 April 2021 Acceptance of Updated Spent Fuel Management Plan ML21089A2092021-03-19019 March 2021 Spent Fuel Pattern Procedure ML21068A3352021-03-0707 March 2021 Acceptance of License Amendment Request to Adopt ISFSI-Only Technical Specifications ML21056A2172021-02-17017 February 2021 Acceptance of License Amendment Request to Revise the Physical Security Plan Requirements ML21032A1852021-02-0101 February 2021 Daec_ CY2021 Inspection Plan ML21006A4052021-01-0606 January 2021 NRR E-mail Capture - Final RAI - Duane Arnold - Post-Shutdown Decommissioning Activities Report ML20338A0032020-12-0101 December 2020 Letter from EPRI to Mr. Scott Wall, BWRVIP 2020-100, 288 Surveillance Capsule Test Results Report ML20316A0212020-11-10010 November 2020 NRR E-mail Capture - Final RAI - Duane Arnold - Duane Arnold Amendment for Proposed Defueled EP and EAL Scheme ML20289A3522020-10-14014 October 2020 NRR E-mail Capture - Duane Arnold Energy Center -Acceptance of Requested Licensing Action, One-Time Exemption from 10 CFR 50, Appendix E, Biennial Emergency Preparedness Exercise Requirements Due to COVID-19 Pandemic (EPID No. L-2020-LLE-01 ML20153A3772020-05-28028 May 2020 NRR E-mail Capture - Request for Additional Information - Duane Arnold Energy Center Quality Assurance Topical Report (FPL-3) - EPID L-2020-LLQ-0002) ML20154K6202020-05-27027 May 2020 COVID-19 Preparedness Assessments for FEMA Region VII Duane Arnold Energy Center (DAEC) and Quad Cities Generating Station (Qcgs) ML20141L8132020-05-19019 May 2020 NRR E-mail Capture - Request for Additional Information - Duane Arnold Energy Center (DAEC) - Exemption Request for Security Training Requirements Due to COVID-19 Pandemic - EPID L-2020-LLE-0042 to 45, L-2020-LLE-0051 ML20129J8282020-05-0606 May 2020 NRR E-mail Capture - LIC-109 Acceptance Review of Duane Arnold Request for Exemption from Portions of 10 CFR 50.47 and Appendix E - EPID L-2020-LLE-0023 ML20127H8662020-05-0505 May 2020 NRR E-mail Capture - Duane Arnold Energy Center (DAEC) - Request for Additional Information (RAI) - Request for Exemptions from 10 CFR 50.82(a)(8)(i)(A) and 1O CFR 50.75(h)(1)(iv) - EPID L-2020-LLE-0011 ML20122A1152020-04-30030 April 2020 NRR E-mail Capture - Duane Arnold Energy Center -Acceptance of Post-Shutdown Decommissioning Activities Report ML20087F2872020-03-26026 March 2020 NRR E-mail Capture - LIC-109 Acceptance Review of Duane Arnold Request for Exemption from 10 CFR 50.82(a)(8)(i)(A) and 1O CFR 50.75(h)(1)(iv) - EPID L-2020-LLE-0011 ML20129J8322020-03-19019 March 2020 NRR E-mail Capture - (External_Sender) Teleconference with Nextra Energy - Duane Arnold Physical Security Plan LIC-109 Review Status ML20022A3602020-01-22022 January 2020 NRR E-mail Capture - Duane Arnold Energy Center - Acceptance of Requested Licensing Action, Proposed Partial Exemption from Record Retention Requirements ML19352G6872019-12-11011 December 2019 12-11-19 Email to FEMA: Response to FEMA Questions on Proposed DAEC Emergency Plan ML19302G3212019-10-29029 October 2019 LIC-109 Acceptance of Duane Arnold Energy Center (DAEC) - License Amendment Request (TSCR- 186) - Removal of License Condition 2.C.(3), Fire Protection Program - EPID L-2019-LLA-0211 ML19302G9732019-10-29029 October 2019 NRR E-mail Capture - LIC-109 Acceptance of Duane Arnold Energy Center (DAEC) - License Amendment Request (TSCR- 186): Removal of License Condition 2.C.(3), Fire Protection Program - EPID L-2019-LLA-0211 ML19280A0352019-10-0404 October 2019 NRR E-mail Capture - Final - RAI Related to License Amendment Request (TSCR-182) for Proposed Changes to the Emergency Plan for Permanently Defueled Conditions at Duane Arnold Energy Center (DAEC) - L-2019-LLA-0075 ML19206A2182019-07-25025 July 2019 NRR E-mail Capture - LIC-109 Acceptance of Duane Arnold Energy Center (DAEC) - License Amendment Request (TSCR-183) - Application to Revise Operating License and TS for Permanently Defueled Condition - EPID L-2019-LLA-0130 ML19183A0172019-06-26026 June 2019 NRR E-mail Capture - LIC-109 Acceptance of Request for Change in the BWRVIP Integrated Surveillance Program Test Schedule to Accommodate Early Closure of the Duane Arnold Energy Center - EPID L-2019-LRO-0042 ML19122A4882019-04-29029 April 2019 NRR E-mail Capture - LIC-109 Acceptance of License Amendment Request (TSCR-182) for Duane Arnold Energy Center (DAEC) - Proposed Changes to the Emergency Plan for Permanently Defueled Condition - EPID L-2019-LLA-0075 ML19086A3502019-03-27027 March 2019 NRR E-mail Capture - LIC-109 Acceptance of the Request for Exemption from 10 CFR 73.55(p)(1)(I) and 10 CFR 73.55(p)(1)(ii) for Duane Arnold Energy Center - EPID L-2019-LLE-0003 ML19064A2032019-03-0404 March 2019 NRR E-mail Capture - Results of LIC-109 Acceptance Review - Duane Arnold Energy Center - Request for Approval of Certified Fuel Handler Training Program, EPID L-2019-LLL-0003 ML18283B0522018-10-0909 October 2018 NRR E-mail Capture - Final Second Round - Request for Additional Information (RAI) - Duane Arnold Energy Center (DAEC) - LAR TSCR-166, Adoption of EAL Scheme Pursuant to NEI 99-01 - EPID L-2017-LLA-0420 ML18255A2922018-09-11011 September 2018 NRR E-mail Capture - Draft Second Round - Request for Additional Information (RAI) - Duane Arnold Energy Center (DAEC) - LAR TSCR-166, Adoption of EAL Scheme Pursuant to NEI 99-01 - EPID L-2017-LLA-0420 ML18166A2982018-06-15015 June 2018 NRR E-mail Capture - Draft Request for Additional Information (RAI) - Duane Arnold Energy Center (DAEC) - LAR TSCR-166, Adoption of EAL Scheme Pursuant to NEI 99-01 - EPID L-2017-LLA-0420 ML18108A3102018-04-12012 April 2018 NRR E-mail Capture - Audit at NextEra Headquarters, Juno Beach, Florida - April 24, 2018 Through April 26, 2018 - 50.69 LARs for Duane Arnold Energy Center (Daec), and Point Beach Nuclear Plant (Pbnp), Units 1 and 2 - EPIDs L-2017-LLA-0283/ ML18088A0102018-03-28028 March 2018 NRR E-mail Capture - Final RAI for Duane Arnold (DAEC) 5th-10 Year ISI (RR-05) ML18037B0032018-02-0606 February 2018 NRR E-mail Capture - Draft Request for Additional Information - Duane Arnold Energy Center (DAEC) - License Amendment Request (TSCR-170), Revision to Technical Specification 3.5.1, ECCS-Operating - EPID L-2017-LLA-0288 ML18025A2362018-01-24024 January 2018 NRR E-mail Capture - Resent - LIC-109 Acceptance - Duane Arnold LAR (TSCR-166) - Adoption of Emergency Action Level (EAL) Scheme Pursuant to NEI 99-01, Revision 6, Development of EALs for Non-Passive Reactors ML18023A0752018-01-22022 January 2018 NRR E-mail Capture - LIC-109 Acceptance - Duane Arnold License Amendment Request (LAR) (TSCR-179) - Application to Add Technical Specification 3.2.3, Linear Heat Generation Rate - EPID: L-2017-LLA-0436 ML18019A0732018-01-18018 January 2018 NRR E-mail Capture - LIC-109 Acceptance - Duane Arnold License Amend Request (LAR)(TSCR-178) - Application to Reduce the Required Number of Operable Suppression Chamber-to-Drywell Vacuum Breakers ML17355A0132017-12-20020 December 2017 NRR E-mail Capture - LIC-109 Acceptance of Duane Arnold LAR TSCR-177, Application to Revise Tech Spec to Adopt TSTF-551, Revise Secondary Containment Surveillance Requirements - EPID: L-2017-LLA-0385 2023-04-19
[Table view] |
Text
NRR-PMDAPEm Resource From: Feintuch, Karl Sent: Friday, February 24, 2012 5:31 PM To: Feintuch, Karl Cc: Feintuch, Karl; Lain, Paul; Fields, Leslie
Subject:
ME7250 - Kewaunee NFPA-805 Withdrawal Acknowledgement Letter - courtesy call of 2/16/2012 - record The meeting convened at 12:00 PM ET and concluded at 12:30 PM ET.
NRC staff attending were:
NRC Headquarters: Paul Lain (AFPB), Daniel Frumkin (AFPB), Leslie Fields (AFPB), Shawn Williams (DORL), Allen Howe (Chairing and DORL), Karl Feintuch (DORL), Gerry Gulla (OE)
NRC Region III: Steven Orth (Region III Enforcement/Investigations Officer), Ronald Langstaff (Inspector, DRS), Kenneth Riemer (Branch Chief, DRP)
SRI (at Kewaunee site): Robert Krsek NRC Legend AFPB = Fire Protection Branch DORL = Division of Reactor Licensing OE = Office of Enforcement DRS = Division of Reactor Safety DRP = Division of Reactor Projects SRI = Senior Resident Inspector Dominion Energy Kewaunee (DEK):
T. Breene DEK J. Gadzala DEK T. Huber DEK B. Koehler DEK J. Martin DEK T. Olson DEK J. Pak DEK R. Repshas DEK C. Sly DEK J. Stafford DEK S. Yuen DEK Summary of discussion:
On February 16, 2012, the Nuclear Regulatory Commission (NRC) staff held a meeting by telephone with Dominion Energy Kewaunee, Inc. (the licensee). The purpose of the meeting was to discuss the licensees withdrawal, by letter dated January 13, 2012, of License Amendment Request (LAR) 250, which would have adopted National Fire Protection Association (NFPA) Standard 805, "Performance-Based Standard for Fire Protection for Light Water Reactor Electric Generating Plants," 2001 Edition, in accordance with Section 50.48(c) of Title 10 of the Code of Federal Regulations (10 CFR 50.48(c)).
NRC staff opened the meeting by summarizing the staffs February 14, 2012 letter (ADAMS Accession No. ML120240007), which advised the licensee that the above-cited application was being treated as a withdrawal from NFPA 805 transition. NRC staff members stated that enforcement discretion associated with NFPA-805 transition no longer applies. They also stated that enforcement discretion discussed in Enforcement Guidance Memorandum EGM-09-002, "Enforcement Discretion for Fire Induced Circuit Faults" (ADAMS Accession No. ML090300446) may apply to certain non-conformances.
1
Dominion staff acknowledged the staff comments and inquired into the timeliness criteria discussed in EGM-09-002. The NRC staff stated that the time criteria for enforcement discretion stated in EGM-09-002 were fixed based on issuance of Regulatory Guide 1.189, Rev 2, Fire Protection for Nuclear Power Plants (i.e.,
enforcement discretion will end for all unresolved noncompliances, regardless of any compensatory measures that are still in place, by November 2012).
NRC staff affirmed, as stated in its letter of February 14, 2012, that since DEK withdrew its amendment request, enforcement discretion, as described in Section 9.1 of the NRC Enforcement Policy (ADAMS Accession No. ML093480037), may continue to apply for noncompliances that DEK has corrected or intends to correct, if reasonable and timely corrective actions are in progress.
2
Hearing Identifier: NRR_PMDA Email Number: 275 Mail Envelope Properties (Karl.Feintuch@nrc.gov20120224173000)
Subject:
ME7250 - Kewaunee NFPA-805 Withdrawal Acknowledgement Letter - courtesy call of 2/16/2012 - record Sent Date: 2/24/2012 5:30:30 PM Received Date: 2/24/2012 5:30:00 PM From: Feintuch, Karl Created By: Karl.Feintuch@nrc.gov Recipients:
"Feintuch, Karl" <Karl.Feintuch@nrc.gov>
Tracking Status: None "Lain, Paul" <Paul.Lain@nrc.gov>
Tracking Status: None "Fields, Leslie" <Leslie.Fields@nrc.gov>
Tracking Status: None "Feintuch, Karl" <Karl.Feintuch@nrc.gov>
Tracking Status: None Post Office:
Files Size Date & Time MESSAGE 3372 2/24/2012 5:30:00 PM Options Priority: Standard Return Notification: No Reply Requested: No Sensitivity: Normal Expiration Date:
Recipients Received: