.1 02/07/2012 U.S. Nuclear Regulatory Commission Operations Center Event Report Pace I Part 21 (PAR) Event# 47643 Rep Org: CURTISS WRIGHT FLOW CONTROL CO. Notification Date / Time: 02/06/2012 17:56 (EST)

Supplier: CURTISS WRIGHT FLOW CONTROL CO. Event Date / Time: 02/06/2012 (CST)

Last Modification: 02/06/2012 Region: 1 Docket #:

City: HUNTSVILLE Agreement State: Yes County: License #:

State: AL NRC Notified by: TONY GILL Notifications: JONATHAN BARTLEY R2DO HQ Ops Officer: CHARLES TEAL PART 21 GROUP EMAIL Emergency Class: NON EMERGENCY 10 CFR Section:

21.21 UNSPECIFIED PARAGRAPH PART 21 - DEFECTIVE PLUG INSULATORS The following report was received via fax:

"This letter is issued to provide initial notification of a potential defect in Plug Insulators (P/N: GB-1A-1) supplied as part of GRAYBOOT 'A' (GB-1A) Connector Kits. There are two affected lots of Plug Insulators (Lot #: BA59961 and BA6771 1). The potential defect is an out of tolerance dimension that will possibly affect the sealing ability of the Plug Insulator to wire interface.

"The affected Customers and their associated Purchase Orders are listed below. All Customers will be notified today.

Ralph a. Hiller; PO: NUC7505, Item 1, 15 Kits (P/N: GB-1A [16-18], Lot BA59961) supplied 19JAN2012.

Bruce Power, PO: 00168187, Item 1, 20 Kits (P/N: GB-1A [12-14], Lot BA59961) supplied 13DEC2011.

Dominion - Surry, PO: 45886290, Item 1, 22 Kits (P/N: GB-S-1A, Lot BA59961) supplied 19DEC2011.

Dominion - Surry, PO: 45897749, Item 2, 30 Kits (P/N: GB-S-1A, Lot BA67711) supplied 01 FEB2012.

Ringhals AB, PO: 621728-053, Item 10, 30 Kits (P/N: GB-1A [16-18], Lot BA59961) supplied 19DEC2011.

Ringhals, PO: 620625-066, Item 10, 300 parts (P/N: GB-1A-1, Lots BA59961/BA67711) supplied 30JAN2012.

Ringhals, PO: 620996-066, Item 50, 1 Kit (P/N: GB-1A [16-18], Lot BA59961) supplied 29NOV2011.

OKG, PO: 4113847, Item 4, 86 parts (P/N: GB-1A-1, Lot BA59961) supplied 30NOV2011.

"It is requested that all affected parts be returned for replacement to QualTech NP; 330 West Park Loop; Huntsville, AL 35806. Customers can contact Cindy Tidwell at (256) 895-7250 ext. 229 for freight collect shipping instructions.

02/07/2012 U.S. Nuclear Regulatory Commission OperationsCenter Event Report Paze2 Part 21 (PAR) Event# 47643 "Additional details, corrective actions and root causes will be provided once complete. If you require additional information or would like to discuss this further please do not hesitate in contacting:"

Tony Gill Quality Assurance Supervisor QualTech NP, Huntsville A business unit of Curtiss-Wright Flow Control Company Office 256-722-8500 ext. 1 Cell 256-426-4558 tgill@curtisswright.com

02/06/2012 17:56 2567229670 EGS PAGE 01/02 I QualToch NP 125 West Perk Loop CUR T155 Huntsville, AL 35606 Phone: 256.722.8500 - Fax: 256.722.8533 www. qualtechnp.com 4w controlCompany QualTech NP FAX TRANSMITTAL DATE: w-NS; KY TO:

FAX NO.

FROM: Iýý ý\ ~ytY~A st~

COMMENTS/INSTRUCTIONS:

ZX'ýZt- xý &ý Q*?r\c5%5' v%QJ$~9 k&tK TRANSMITTAL INCLUDES COVER SHEET PLUS .A..S)PAGE(S).

02/06/2012 17:56 2567229670 EGS PAGE 02/02 Huntsville Operations ST pr m

125 & 330 West Park Loop Huntsville, AL 35806 QualTech NP 256-722-8500 (File No.: QTHuntsvillelOCFR21-2012-01)

February 06, 2012 To whom it may concern:

This letter is issued to provide initial notification of a potential defect in Plug Insulators (P/N: GB-lA-I) supplied as part of GRAYBOOT "A" (GB-IA) Connector Kits. There are two affected lots of Plug Insulators (Lot #: BA59961 and BA67711)- The potential defect is an out of tolerance dimension that will possibly affect the scaling ability of the Plug Insulator to wire interface.

The affected Customers and their associated Purchase Orders are listed below. All Customers will be notified today.

Ralph a. Hiller; PO: NUC7505, Item.., 15 Kits (P/N: GB-1A [16-18], Lot BA59961) supplied 19JAN2012.

Bruce Power, PO: 00168187, Item 1, 20 Kits (P/N: GB-lA [12-14], Lot BA59961) supplied 13DEC2011.

Dominion - Surry, PO: 45886290, Item 1, 22 Kits (P/N: GB-S-1A. Lot BA59961) supplied 19DEC20i 1.

Dominion - Sutry, PO: 45897749, Item 2, 30 Kits (P/N: GB-S-lA, Lot BA6771 1) supplied O1FEB2012.

Ringhals AB, PO: 621728-053, Item 10, 30 Kits (P/N: GB-lA t.16-18], Lot BA59961) supplied 19DEC201 1.

Ringhals, PO: 620625-066, Item 10, 300 parts (P/N: GB-lA-1, Lots BA59961/BA67711) supplied 30JAN2012.

Ringhals, PO: 620996-066. Item 50, 1 Kit (P/N: GB-lA [16-18], Lot BA59961) supplied 29NOV201 1.

OKG, PO: 4113847, Item 4, 86 parts (P/N: GB-lA-1, Lot BA59961) supplied 30NOV201 1.

It is requested that all affected. parts be returned for replacement to QualTech NP; 330 West Park Loop; Huntsville, AL 35806. Customers can contact Cindy Tidwell at (256) 895-7250 ext. 229 for freight collect shipping instructions.

Additional details, corrective actions and root causes will be provided once complete. If you require additional information or would like to discuss this further please do not hesitate in contacting me.

Sincerely, Tony6ý Quality Assurance Supervisor QualTecb NP, Huntsville a business unit of Curtiss-Wright Flow Control Company Office 256-722-8500 ext. 13 1 Cell 256-426-4.558 tgill@curtisswright.com