Other: CNL-14-201, Response to Questions Regarding the Unit 1/Unit 2 As-Constructed Fire Protection Report, CNL-15-174, Submittal of Updated Pages for Unit 1/Unit 2 As-Constructed Fire Protection Report & License Condition 2.C(9) Addition Request, CNL-15-214, Updated Pages for As-Constructed Fire Protection Report, ML113500239, ML12207A080, ML13051A045, ML13081A002, ML13081A003, ML14265A449, ML15175A508
|
MONTHYEARML1000800082010-01-11011 January 2010 Notice of Forthcoming Conference Call with Tennessee Valley Authority Sequoyah Nuclear Plant, Units 1 & 2; Watts Bar Unit 1 Project stage: Request ML1001914212010-01-11011 January 2010 Final Safety Analysis Report, Amendment 97 Project stage: Request ML1013701862010-05-14014 May 2010 OL - FW: Call Summary - TVA Clarification Call Project stage: Request ML1015401332010-06-10010 June 2010 Request for Additional Information Regarding Licensees Final Safety Analysis Report Amendment Related to Accident Dose Project stage: RAI ML1019402362010-06-18018 June 2010 Instrumentation and Controls Staff Information Requests Project stage: Request ML1018201562010-06-18018 June 2010 OL - Updated Open Items List Project stage: Request ML1015402502010-06-24024 June 2010 Request for Additional Information Regarding Licensees Final Safety Analysis Report Amendment Related to Nuclear Performance and Code Review, Plant Systems, and Testing (Tac Nos. ME2731 and ME3091) Project stage: RAI ML1016002782010-07-12012 July 2010 Request for Additional Information Regarding Licensees Final Safety Analysis Report Amendment Related to Accident Dose Project stage: RAI ML1019506102010-07-30030 July 2010 Request for Additional Information, Licensees Final Safety Analysis Report Amendment Related to Chapters 3.9.1, 3.9.2, and 3.9.3 Project stage: RAI ML1019404742010-07-30030 July 2010 Request for Additional Information, Licensees Final Safety Analysis Report Amendment Related to Chapter 10.4.7 Project stage: RAI ML1026305982010-09-28028 September 2010 Request for Additional Information, Regarding Final Safety Analysis Report Related to Sections 3.2 and 5.2 Project stage: RAI ML1029901502010-10-26026 October 2010 Cancelled - Notice of Meeting with (Tva), to Discuss Responses to the NRC Requests for Additional Information (Rals) for Generic Letter 2004-02, Potential Impact of Debris Blockage on Emergency Recirculation During Design Basis Project stage: RAI ML1035401772010-12-20020 December 2010 Notice of Meeting with Tennessee Valley Authority to Discuss Watts Bar Nuclear Plant, Unit 2, Final Safety Analysis Report Related to Section 7 Instrumentation and Control Project stage: Request ML1036101142010-12-21021 December 2010 Submittal of Pre-op Test Instruction Project stage: Request ML1101401972011-01-14014 January 2011 Notice of Meeting with Tennessee Valley Authority to Discuss Watts Bar Nuclear Plant, Unit 2, Final Safety Analysis Report Related to Section 7 Instrumentation and Control Project stage: Request ML1102801282011-02-0909 February 2011 Request for Additional Information, Regarding Final Safety Analysis Report Amendment Related to Section 9.5.1 Fire Protection System Project stage: RAI ML1106107452011-03-10010 March 2011 Request for Additional Information, Regarding Final Safety Analysis Report Related to Section 9.5.1 Fire Protection Report - Round 2 Project stage: RAI ML1107705372011-03-16016 March 2011 Instrumentation and Controls Staff Information Requests Project stage: Request ML1109104642011-04-13013 April 2011 Summary of Meeting with Tennessee Valley Authority to Discuss Watts Bar Nuclear Plant, Unit 2, Final Safety Analysis Report Related to Section 9.5.1 Fire Protection Project stage: Meeting ML1109607652011-04-25025 April 2011 Request for Additional Information Regarding Final Safety Analysis Report Related to Section 9.5.1 Fire Protection Round 3 Project stage: RAI ML11129A1582011-05-0606 May 2011 Request for Additional Information Regarding Fire Protection Report, Project stage: Request ML11165A1452011-05-18018 May 2011 OL - Commitments and Sser Open Items Project stage: Request ML1112404832011-05-23023 May 2011 Request for Additional Information Regarding Final Safety Analysis Report Related to Section 9.5.1 Fire Protection Round 4 Project stage: RAI ML1115201192011-05-26026 May 2011 Response to Request for Additional Information Regarding Fire Protection Report Project stage: Response to RAI ML1114506732011-05-26026 May 2011 July 14, 2011 Notice of Forthcoming Meeting with Tennessee Valley Authority (TVA) to Discuss Bellefonte Nuclear Plant, Unit 1, Digital Instrumentation and Control and Human Factors Project stage: Request ML11161A1282011-06-0707 June 2011 Safety Evaluation Report Supplement 22 (Sser 22) - Second Response to NRC Required Action Items Project stage: Request ML1115109792011-06-0808 June 2011 Request for Additional Information Regarding Final Safety Analysis Report Related to Section 9.5.1 Fire Protection Round 5 Project stage: RAI ML11186A8642011-07-0101 July 2011 Submittal of Report in Accordance with 10 CFR 26.719(c)(1) for Drug and Alcohol Testing Errors Project stage: Request ML11200A1092011-07-14014 July 2011 Meeting Slides - TVA Phase 0 Meeting Bln/Nrc Bellefonte Digital I & C Upgrades Project stage: Request ML11200A1152011-07-14014 July 2011 Meeting Slides - TVA Phase 0 Meeting with NRC Bellefonte Units 1 & 2 Main Control Room Modernization Project stage: Request ML1118235802011-07-21021 July 2011 Request for Additional Information Regarding Final Safety Analysis Report Related to Section 9.5.1 Fire Protection Group 6 Project stage: RAI ML1120000992011-07-22022 July 2011 July 14, 2011 Summary of Pre-Application Meeting with Tennessee Valley Authority Regarding Digital Instrumentation and Control and Human Factors for the Potential, Proposed Updated Operating License Application at Bellefonte Nuclear Plant, Project stage: Meeting ML1120303872011-07-27027 July 2011 Request for Additional Information Regarding Incore Instrumentation System Project stage: RAI ML11215A1322011-07-29029 July 2011 Response to Request for Additional Information Regarding June 28, 2011 NRC Audit- Steam Line Break (Slb) and Other Miscellaneous RAIs Project stage: Response to RAI ML11227A2572011-08-0505 August 2011 Request for Additional Information (RAI) Group 6 Regarding Fire Protection Report Project stage: Request ML11230A3852011-08-15015 August 2011 Transmittal of Revised Unit 1 / Unit 2 As-Designed Fire Protection Report Project stage: Request ML1124904742011-09-14014 September 2011 Request for Additional Information Regarding Final Safety Analysis Report Related to Section 9.5.1 Fire Protection Group 7 Project stage: RAI ML11286A0352011-09-30030 September 2011 OL - Additional Draft RAI on Fire Protection - Group 8 Project stage: Request ML11286A0382011-09-30030 September 2011 OL - Draft RAIs on Fire Protection - Group 8 Project stage: Request ML13060A2252011-09-30030 September 2011 Response to Request for Additional Information Group 7 Regarding Fire Protection Report, (TAC No. ME3091) (Public Version) Project stage: Response to RAI ML11306A0902011-10-28028 October 2011 Response to Request for Additional Information Group 8 Regarding Fire Protection Report Project stage: Response to RAI ML11322A1032011-11-30030 November 2011 WCAP-17529-NP, Rev. 0, System Requirements Specification for the Common Q Post Accident Monitoring System Project stage: Request ML1135002392011-12-20020 December 2011 Audit Report of Fire Protection Relating to Final Safety Analysis Report Accident Analyses Project stage: Other ML12054A0622012-03-13013 March 2012 Summary of Public Meeting with Tennessee Valley Authority Regarding Watts Bar Nuclear Plant, Unit 2, Final Safety Analysis Report Related to Fire Protection Project stage: Request ML1207905812012-03-23023 March 2012 Request for Additional Information Regarding Final Safety Analysis Report Related to Section 9.5.1, Fire Protection Group 8 Project stage: RAI ML12142A0262012-05-17017 May 2012 OL - Request for Additional Information Regarding Fire Protection Review Group 10 Project stage: RAI ML12153A3742012-05-30030 May 2012 Watts, Unit 2, Response to Request for Additional Information Project stage: Response to RAI ML12181A5312012-06-27027 June 2012 Resolution of Concerns with Fire Protection Report (FPR) Operator Manual Action (OMA) 732 and Response to Requests for Additional Information Project stage: Response to RAI ML12207A0802012-07-19019 July 2012 Resolution of Concerns with Fire Protection Report Operator Manual Action 732 - Commitment Schedule Update Project stage: Other ML13051A0452013-02-14014 February 2013 Updated Response to NRC Bulletin 2011-01, Mitigation Strategies Project stage: Other 2011-05-23
[Table View] |
Text
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, O.C. 20555-0001 July 27, 2011 Mr. Ashok S. Bhatnagar Senior Vice President Nuclear Generation Development and Construction Tennessee Valley Authority 6A Lookout Place 1101 Market Street Chattanooga, TN 37402-2801
SUBJECT:
WATTS BAR NUCLEAR PLANT, UNIT 2 - REQUEST FOR ADDITIONAL INFORMATION REGARDING INCORE INSTRUMENTATION SYSTEM (TAC NO. ME3091)
Dear Mr. Bhatnagar:
By letters dated May 6, and June 10 and 23, 2011, Tennessee Valley Authority provided additional information related to Section 7.7.1.9, "Incore I nstrumentation System," of the Final Safety Analysis Report for Watts Bar Nuclear Plant, Unit 2. In addition, the U.S. Nuclear Regulatory Commission staff conducted an audit on July 14, 2011, at the Westinghouse Electric Corporation Office in Rockville, Maryland, to evaluate information regarding flow-induced vibration effects on the incore instrumentation thimble assemblies.
The NRC staff has reviewed the information provided and determined that further information is required to complete its assessment of your submittals. The specific questions are discussed in the enclosed Request for Additional Information.
A response is required within 30 days of receipt of this letter.
If you should have any questions, please contact me at 301-415-1457.
Sincerely, rj)-JJ. m~,-
Patrick D. Milano, Senior Project Manager Watts Bar Special Projects Branch Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-391
Enclosure:
Request for Additional Information cc w/encl: Distribution via Listserv
Request for Additional Information (RAn Watts Bar Nuclear Plant, Unit 2 Final Safety Analysis Report Section 7.7.1.9 Tennessee Valley Authority Docket No. 50-391 By letters dated May 6, and June 10 and 23, 2011, Tennessee Valley Authority provided additional information related to Section 7.7.1.9, "Incore Instrumentation System," of the Final Safety Analysis Report for Watts Bar Nuclear Plant (WBN). Unit 2. The Nuclear Regulatory Commission (NRC) staff has reviewed the information provided and has determined that the following information is required to complete its review.
- 1.
EMCB RAI1 The work performed to demonstrate the acceptable behavior of the WBN Unit 2 incore instrument thimble assemblies (IiTAs) against mechanical wear resulting from flow-induced vibration is based on a comparative analysis. With respect to the use of the comparative method for evaluating the vibratory response of a referenced nuclear plant's in-core instrument assemblies and the WBN Unit 2 liTAs, provide a justification that demonstrates that the comparative method is acceptable for use in the analysis of the WBN Unit 2 IITAs. This justification should include, but not be limited to, citation of regulatory precedents involving the use of the comparative method and the results of any benchmarking performed against other methods of analysis involving vibratory excitation resulting from parallel flow across structures similar to the "TAs.
- 2.
EMCB RAI2 As stated in EMCB RAI 1, the comparative analysis performed for the WBN Unit 2 liTAs to determine whether the IITAs exhibit satisfactory vibration amplitudes resulting from parallel flow between the IITAs and the supporting structures and is based on using the comparative method to contrast the calculated amplitudes for the WBN Unit 2 and the referenced plant in-core instrumentation. During an audit at the Westinghouse offices on July 14, 2011, the NRC staff reviewed the documentation of the vibration analysis performed for the WBN Unit 2 I IT As, which indicated that the acceptance criterion used to justify the satisfactory behavior of the WBN Unit 2 IITAs is based on the vibration amplitudes resulting from the WBN Unit 2 IITA analysis being less than 105 percent of the vibration amplitudes calculated for the referenced plant in-core instrumentation. However, no justification was provided for why the referenced plant vibration amplitudes are acceptable. Therefore, provide a technical justification that demonstrates how the referenced plant calculated vibration amplitudes of the in-core instrumentation provide reasonable assurance that unsatisfactory mechanical wear of these components due to flow-induced vibration will not occur. Additionally, provide justification that shows that the calculated peak vibration amplitude for the WBN Unit 2 IITAs is acceptable from a quantitative standpoint. This justification should compare the calculated value to the dimensional details and structural design of the I IT As to demonstrate that vibratory motion of the IITAs would not result in unacceptable mechanical wear.
Enclosure
July 27, 2011 Mr. Ashok S. Bhatnagar Senior Vice President Nuclear Generation Development and Construction Tennessee Valley Authority 6A Lookout Place 1101 Market Street Chattanooga, TN 37402-2801 SUB"IECT:
WATTS BAR NUCLEAR PLANT, UNIT 2 - REQUEST FOR ADDITIONAL INFORMATION REGARDING INCORE INSTRUMENTATION SYSTEM (TAC NO. ME3091)
Dear Mr. Bhatnagar:
By letters dated May 6, and June 10 and 23,2011, Tennessee Valley Authority provided additional information related to Section 7.7.1.9, "Incore Instrumentation System," of the Final Safety Analysis Report for Watts Bar Nuclear Plant, Unit 2. In addition, the U.S. Nuclear Regulatory Commission staff conducted an audit on July 14, 2011, at the Westinghouse Electric Corporation Office in Rockville, Maryland, to evaluate information regarding flow-induced vibration effects on the incore instrumentation thimble assemblies.
The NRC staff has reviewed the information provided and determined that further information is required to complete its assessment of your submittals. The specific questions are discussed in the enclosed Request for Additional Information.
A response is required within 30 days of receipt of this letter.
If you should have any questions, please contact me at 301-415-1457.
Sincerely, IRA!
Patrick D. Milano, Senior Project Manager Watts Bar Special Projects Branch Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-391
Enclosure:
Request for Additional Information cc w/encl: Distribution via Listserv DISTRIBUTION:
PUBLIC RidsNrrPMWattsBar2 Resource RidsRgn2MailCenter Resource LPWB Reading File RidsNrrDeEmcb Resource RidsOgcRp Resource RidsNrrDorlLpwb Resource RidsNrrLABClayton Resource RidsNrrDorlDpr RidsAcrsAcnw_MailCTR Resource ADAMS Accession No. NIL112030387
- OFFICE LPWB/PM LPWB/LA EMCB/BC OGC NLO LPWB/BC I NAME PMilano BClayton MKhanna (ATsirigotis for)
DRoth SCampbell I DATE 07/21/11 07/21/11 07/21/11 07/26/11 07/27/11 OFFICIAL AGENCY RECORD