ES-301 Administrative Topics Outline Form ES-301-1 Facility: _________Perry______________________

Date of Examination: ___06/14/1010_

Examination Level: RO ; SRO Operating Test Number: __2010-301 Administrative Topic (see Note)

Type Code*

Describe activity to be performed Conduct of Operations D, S Perform a Valve and System Lineup on RCIC Conduct of Operations D, R Determine Requirements to Reactivate a License Equipment Control M, R Determine Drywell Floor and Equipment Drain Leakage Radiation Control D, R Evaluate an RWP and Survey Map Emergency Procedures/Plan n/a NOTE: All items (5 total) are required for SROs. RO applicants require only 4 items unless they are retaking only the administrative topics, when all 5 are required.

  • Type Codes & Criteria:

(C)ontrol room, (S)imulator, or Class(R)oom (D)irect from bank ( 3 for ROs; 4 for SROs & RO retakes)

(N)ew or (M)odified from bank ( 1)

(P)revious 2 exams ( 1; randomly selected)

ES-301 Administrative Topics Outline Form ES-301-1 Facility: _________Perry______________________

Date of Examination: ___06/14/1010_

Examination Level: RO SRO ;

Operating Test Number: __2010-301 Administrative Topic (see Note)

Type Code*

Describe activity to be performed Conduct of Operations D, S Perform a Valve and System Lineup on RCIC Conduct of Operations D, R Determine Requirements to Reactivate a License Equipment Control M, R Determine Drywell Floor and Equipment Drain Leakage Radiation Control D, R Evaluate an RWP and Survey Map Emergency Procedures/Plan D, R Classify an Event and Determine a PAR NOTE: All items (5 total) are required for SROs. RO applicants require only 4 items unless they are retaking only the administrative topics, when all 5 are required.

  • Type Codes & Criteria:

(C)ontrol room, (S)imulator, or Class(R)oom (D)irect from bank ( 3 for ROs; 4 for SROs & RO retakes)

(N)ew or (M)odified from bank ( 1)

(P)revious 2 exams ( 1; randomly selected)

ES-301 Control Room/In-Plant Systems Outline Form ES-301-2 Facility: _____Perry________________________

Date of Examination: ___06/14/2010_

Exam Level: RO ; SRO-I SRO-U Operating Test No.: ____2010-301___

Control Room Systems@ (8 for RO); (7 for SRO-I); (2 or 3 for SRO-U, including 1 ESF)

System / JPM Title Type Code*

Safety Function

a. Bypass and Reset Scram/ARI Signals During an ATWS C, M 1
b. Bypass HPCS and MFP Level 8 Trip for RPV Flooding C, D 2
c. Start Vacuum Pumps following a Loss of Condenser Vacuum A, S, L, M 3
d. Establish Shutdown Cooling, Head Spray then Trip Pump Due to Loss of Suction Pressure A, S, L, M 4
e. Initiate Suppression Pool Makeup (SPMU)

C, D 5

f. Restore Off-Site Power D, L, C 6
g. Control Rod Bypassed in RACCS C, D 7
h. Bypass Instrument Air Isolation and Start an Air Compressor A, M, S 8

In-Plant Systems@ (3 for RO); (3 for SRO-I); (3 or 2 for SRO-U)

i. Perform Alternate Boron Injection D, E, P, R 1
j. Isolate an Instrument Air Receiver A, M, E 8
k. LPCI B Shutdown at Division 2 Remote Shutdown Panel D, E, L 7

All RO and SRO-I control room (and in-plant) systems must be different and serve different safety functions; all 5 SRO-U systems must serve different safety functions; in-plant systems and functions may overlap those tested in the control room.

  • Type Codes Criteria for RO / SRO-I / SRO-U (A)lternate path (C)ontrol room (D)irect from bank (E)mergency or abnormal in-plant (EN)gineered safety feature (L)ow-Power / Shutdown (N)ew or (M)odified from bank including 1(A)

(P)revious 2 exams (R)CA (S)imulator 4-6 / 4-6 / 2-3 9 / 8 / 4 1 / 1 / 1

- / - / 1 (control room system) 1 / 1 / 1 2 / 2 / 1 3 / 3 / 2 (randomly selected) 1 / 1 / 1

ES-301 Control Room/In-Plant Systems Outline Form ES-301-2 Facility: _____Perry________________________

Date of Examination: ___06/14/2010_

Exam Level: RO SRO-I ; SRO-U Operating Test No.: ____2010-301____

Control Room Systems@ (8 for RO); (7 for SRO-I); (2 or 3 for SRO-U, including 1 ESF)

System / JPM Title Type Code*

Safety Function

a. Bypass and Reset Scram/ARI Signals During an ATWS C, M 1
b. Bypass HPCS and MFP Level 8 Trip for RPV Flooding C, D 2
c. Start Vacuum Pumps following a Loss of Condenser Vacuum A, S, L, M 3
d. Establish Shutdown Cooling, Head Spray then Trip Pump Due to Loss of Suction Pressure A, S, L, M 4
e. Initiate Suppression Pool Makeup (SPMU)

C, D 5

f. Restore Off-Site Power D, L, C 6
g. n/a n/a n/a
h. Bypass Instrument Air Isolation and Start an Air Compressor A, M, S 8

In-Plant Systems@ (3 for RO); (3 for SRO-I); (3 or 2 for SRO-U)

i. Perform Alternate Boron Injection D, E, P, R 1
j. Isolate an Instrument Air Receiver A, M, E 8
k. LPCI B Shutdown at Division 2 Remote Shutdown Panel D, E, L 7

All RO and SRO-I control room (and in-plant) systems must be different and serve different safety functions; all 5 SRO-U systems must serve different safety functions; in-plant systems and functions may overlap those tested in the control room.

  • Type Codes Criteria for RO / SRO-I / SRO-U (A)lternate path (C)ontrol room (D)irect from bank (E)mergency or abnormal in-plant (EN)gineered safety feature (L)ow-Power / Shutdown (N)ew or (M)odified from bank including 1(A)

(P)revious 2 exams (R)CA (S)imulator 4-6 / 4-6 / 2-3 9 / 8 / 4 1 / 1 / 1

- / - / 1 (control room system) 1 / 1 / 1 2 / 2 / 1 3 / 3 / 2 (randomly selected) 1 / 1 / 1

ES-301 Control Room/In-Plant Systems Outline Form ES-301-2 Facility: _____Perry________________________

Date of Examination: ___06/14/2010_

Exam Level: RO SRO-I SRO-U ;

Operating Test No.: ____2010-301___

Control Room Systems@ (8 for RO); (7 for SRO-I); (2 or 3 for SRO-U, including 1 ESF)

System / JPM Title Type Code*

Safety Function

a.
b.
c.
d. Establish Shutdown Cooling, Head Spray then Trip Pump Due to Loss of Suction Pressure A, S, L, M 4

e Initiate Suppression Pool Makeup (SPMU)

C, D, EN 5

f. Restore Off-Site Power D, L, C 6
g.
h.

In-Plant Systems@ (3 for RO); (3 for SRO-I); (3 or 2 for SRO-U)

i. Perform Alternate Boron Injection D, E, P, R 1
j. Isolate an Instrument Air Receiver A, M, E 8
k.

All RO and SRO-I control room (and in-plant) systems must be different and serve different safety functions; all 5 SRO-U systems must serve different safety functions; in-plant systems and functions may overlap those tested in the control room.

  • Type Codes Criteria for RO / SRO-I / SRO-U (A)lternate path (C)ontrol room (D)irect from bank (E)mergency or abnormal in-plant (EN)gineered safety feature (L)ow-Power / Shutdown (N)ew or (M)odified from bank including 1(A)

(P)revious 2 exams (R)CA (S)imulator 4-6 / 4-6 / 2-3 9 / 8 / 4 1 / 1 / 1

- / - / 1 (control room system) 1 / 1 / 1 2 / 2 / 1 3 / 3 / 2 (randomly selected) 1 / 1 / 1

NUREG-1021, Revision 9 Supplement 1 Page 1 of 4 FENOC Facsimile Rev. 0 ES-301 Transient and Event Checklist Form ES-301-5 Facility Perry Date of Exam 6/14/2010 Operating Test No 2010-01 A

P P

L I

C A

N T

E V

E N

T T

Y P

E Scenarios 1

6 3

4 Backup T

O T

A L

M I

N I

M U

M(*)

CREW POSITION CREW POSITION CREW POSITION CREW POSITION S

R O

A T

C B

O P

S R

O A

T C

B O

P S

R O

A T

C B

O P

S R

O A

T C

B O

P R

I U

M A

S T

E R

RX 2

1 3

1 1

1 0

NOR 1,2 1

1,2 2

1,3 1

1 1

1 1

I/C 3,4,5,7, 8,9 8,9 3,4,5,7 3,4,6,7 3,4 3,6,7 2,4,5,7, 9

4,9 2,5,7 2,4,6,8, 9,11 2,8 4,6,9, 11 4

4 2

MAJ 6,10 6,10 6,10 5

5 5

6,8 6,8 6,8 7,10 7,10 7,10 2

2 1

TS 3,4,5 3,4 4,5 3,4 0

2 2

SRO-I-1 RX 1

1 1

1 0

NOR 1,2 1

3 1

1 1

I/C 3,4,5,7, 8,9 3,4 2,5,7 11 4

4 2

MAJ 6,10 5

6,8 5

2 2

1 TS 3,4,5 3

0 2

2 SRO-I-2 RX 2

1 1

1 0

NOR 2

1,3 3

1 1

1 I/C 8,9 3,6,7 2,4,5,7, 9

10 4

4 2

MAJ 6,10 5

6,8 5

2 2

1 TS 4,5 2

0 2

2 SRO-I-3 RX 3

1 1

1 0

NOR 1

1,2 3

1 1

1 I/C 3,4,5,7 3,4,6,7 4,9 10 4

4 2

MAJ 6,10 5

6,8 5

2 2

1 TS 3,4 2

0 2

2 Instructions:

1.

Check the applicant level and enter the operating test number and Form ES-D-1 event numbers for each event type; TS are not applicable for RO applicants. ROs must serve in both the at-the-controls (ATC) and balance-of-plant (BOP) positions; Instant SROs must serve in both the SRO and the ATC positions, including at least two instrument or component (I/C) malfunctions and one major transient, in the ATC position. If an Instant SRO additionally serves in the BOP position, one I/C malfunction can be credited toward the two I/C malfunctions required for the ATC position.

2.

Reactivity manipulations may be conducted under normal or controlled abnormal conditions (refer to Section D.5.d) but must be significant per section C.2.a of Appendix D. (*) Reactivity and normal evolutions may be replaced with additional instrument or component malfunctions on a 1-for-1 basis.

3.

Whenever practical, both instrument and component malfunctions should be included; only those that require verifiable actions that provide insight to the applicants competence count toward the minimum requirements specified for the applicants license level in the right hand columns.

NUREG-1021, Revision 9 Supplement 1 Page 2 of 4 FENOC Facsimile Rev. 0 ES-301 Transient and Event Checklist Form ES-301-5 Facility Perry Date of Exam 6/14/2010 Operating Test No 2010-01 A

P P

L I

C A

N T

E V

E N

T T

Y P

E Scenarios 1

6 3

4 Backup T

O T

A L

M I

N I

M U

M(*)

CREW POSITION CREW POSITION CREW POSITION CREW POSITION S

R O

A T

C B

O P

S R

O A

T C

B O

P S

R O

A T

C B

O P

S R

O A

T C

B O

P R

I U

M A

S T

E R

RX 2

1 3

1 1

1 0

NOR 1,2 1

1,2 2

1,3 1

1 1

1 1

I/C 3,4,5,7, 8,9 8,9 3,4,5,7 3,4,6,7 3,4 3,6,7 2,4,5,7, 9

4,9 2,5,7 2,4,6,8, 9, 11 2,8 4,6,9, 11 4

4 2

MAJ 6,10 6,10 6,10 5

5 5

6,8 6,8 6,8 7,10 7,10 7,10 2

2 1

TS 3,4,5 3,4 4,5 3,4 0

2 2

SRO-I-4 RX 1

1 1

1 0

NOR 1,2 1

3 1

1 1

I/C 3,4,5,7, 8,9 3,4 2,5,7 11 4

4 2

MAJ 6,10 5

6,8 5

2 2

1 TS 3,4,5 3

0 2

2 SRO-I-5 RX 2

1 1

1 0

NOR 2

1,3 3

1 1

1 I/C 8,9 3,6,7 2,4,5,7, 9

10 4

4 2

MAJ 6,10 5

6,8 5

2 2

1 TS 4,5 2

0 2

2 SRO-I-6 RX 3

1 1

1 0

NOR 1

1,2 3

1 1

1 I/C 3,4,5,7 3,4,6,7 4,9 10 4

4 2

MAJ 6,10 5

6,8 5

2 2

1 TS 3,4 2

0 2

2 Instructions:

1.

Check the applicant level and enter the operating test number and Form ES-D-1 event numbers for each event type; TS are not applicable for RO applicants. ROs must serve in both the at-the-controls (ATC) and balance-of-plant (BOP) positions; Instant SROs must serve in both the SRO and the ATC positions, including at least two instrument or component (I/C) malfunctions and one major transient, in the ATC position. If an Instant SRO additionally serves in the BOP position, one I/C malfunction can be credited toward the two I/C malfunctions required for the ATC position.

2.

Reactivity manipulations may be conducted under normal or controlled abnormal conditions (refer to Section D.5.d) but must be significant per section C.2.a of Appendix D. (*) Reactivity and normal evolutions may be replaced with additional instrument or component malfunctions on a 1-for-1 basis.

3.

Whenever practical, both instrument and component malfunctions should be included; only those that require verifiable actions that provide insight to the applicants competence count toward the minimum requirements specified for the applicants license level in the right hand columns.

NUREG-1021, Revision 9 Supplement 1 Page 3 of 4 FENOC Facsimile Rev. 0 ES-301 Transient and Event Checklist Form ES-301-5 Facility Perry Date of Exam 6/14/2010 Operating Test No 2010-01 A

P P

L I

C A

N T

E V

E N

T T

Y P

E Scenarios 1

6 3

4 Backup T

O T

A L

M I

N I

M U

M(*)

CREW POSITION CREW POSITION CREW POSITION CREW POSITION S

R O

A T

C B

O P

S R

O A

T C

B O

P S

R O

A T

C B

O P

S R

O A

T C

B O

P R

I U

M A

S T

E R

RX 2

1 3

1 1

1 0

NOR 1,2 1

1,2 2

1,3 1

1 1

1 1

I/C 3,4,5,7, 8,9 8,9 3,4,5,7 3,4,6,7 3,4 3,6,7 2,4,5,7, 9

4,9 2,5,7 2,4,6,8, 9,11 2,8 4,6,9, 11 4

4 2

MAJ 6,10 6,10 6,10 5

5 5

6,8 6,8 6,8 7,10 7,10 7,10 2

2 1

TS 3,4,5 3,4 4,5 3,4 0

2 2

SRO-I-7 RX 1

1 1

1 0

NOR 1,2 1

3 1

1 1

I/C 3,4,5,7, 8,9 3,4 2,5,7 11 4

4 2

MAJ 6,10 5

6,8 5

2 2

1 TS 3,4,5 3

0 2

2 SRO-I-8 RX 2

1 1

1 0

NOR 2

1,3 3

1 1

1 I/C 8,9 3,6,7 2,4,5,7, 9

10 4

4 2

MAJ 6,10 5

6,8 5

2 2

1 TS 4,5 2

0 2

2 SRO-I-9 RX 3

1 1

1 0

NOR 1

1,2 3

1 1

1 I/C 3,4,5,7 3,4,6,7 4,9 10 4

4 2

MAJ 6,10 5

6,8 5

2 2

1 TS 3,4 2

0 2

2 Instructions:

1.

Check the applicant level and enter the operating test number and Form ES-D-1 event numbers for each event type; TS are not applicable for RO applicants. ROs must serve in both the at-the-controls (ATC) and balance-of-plant (BOP) positions; Instant SROs must serve in both the SRO and the ATC positions, including at least two instrument or component (I/C) malfunctions and one major transient, in the ATC position. If an Instant SRO additionally serves in the BOP position, one I/C malfunction can be credited toward the two I/C malfunctions required for the ATC position.

2.

Reactivity manipulations may be conducted under normal or controlled abnormal conditions (refer to Section D.5.d) but must be significant per section C.2.a of Appendix D. (*) Reactivity and normal evolutions may be replaced with additional instrument or component malfunctions on a 1-for-1 basis.

3.

Whenever practical, both instrument and component malfunctions should be included; only those that require verifiable actions that provide insight to the applicants competence count toward the minimum requirements specified for the applicants license level in the right hand columns.

NUREG-1021, Revision 9 Supplement 1 Page 4 of 4 FENOC Facsimile Rev. 0 ES-301 Transient and Event Checklist Form ES-301-5 Facility Perry Date of Exam 6/14/2010 Operating Test No 2010-01 A

P P

L I

C A

N T

E V

E N

T T

Y P

E Scenarios 5

2 N/A N/A T

O T

A L

M I

N I

M U

M(*)

CREW POSITION CREW POSITION CREW POSITION CREW POSITION S

R O

A T

C B

O P

S R

O A

T C

B O

P S

R O

A T

C B

O P

S R

O A

T C

B O

P R

I U

M A

S T

E R

RX 2

3 1

1 0

NOR 1,2 1

1,3 1

1 1

1 I/C 3,4,5,6, 8

3,5,6,8 4,6 2,4,5,9 2,4 5,9 4

4 2

MAJ 7,9,10 7,9,10 7,9,10 6,7,8 6,7,8 6,7,8, 2

2 1

TS 3

1,2,4 0

2 2

SRO-U-1 RX 0

1 1

0 NOR 1,2 1,3 4

1 1

1 I/C 3,4,5,6, 8

2,4,5,9 9

4 4

2 MAJ 7,9,10 6,7,8 6

2 2

1 TS 3

1,2,4 4

0 2

2 RO-1 RX 2

1 1

1 0

NOR 1

1 1

1 1

I/C 3,5,6,8 5,9 6

4 4

2 MAJ 7,9,10 6,7,8, 6

2 2

1 TS 0

0 2

2 RX 1

1 0

NOR 1

1 1

I/C 4

4 2

MAJ 2

2 1

TS 0

2 2

Instructions:

1.

Check the applicant level and enter the operating test number and Form ES-D-1 event numbers for each event type; TS are not applicable for RO applicants. ROs must serve in both the at-the-controls (ATC) and balance-of-plant (BOP) positions; Instant SROs must serve in both the SRO and the ATC positions, including at least two instrument or component (I/C) malfunctions and one major transient, in the ATC position. If an Instant SRO additionally serves in the BOP position, one I/C malfunction can be credited toward the two I/C malfunctions required for the ATC position.

2.

Reactivity manipulations may be conducted under normal or controlled abnormal conditions (refer to Section D.5.d) but must be significant per section C.2.a of Appendix D. (*) Reactivity and normal evolutions may be replaced with additional instrument or component malfunctions on a 1-for-1 basis.

3.

Whenever practical, both instrument and component malfunctions should be included; only those that require verifiable actions that provide insight to the applicants competence count toward the minimum requirements specified for the applicants license level in the right hand columns.

ES-301 Competencies Checklist Form ES-301-6 Facility: Perry Date of Examination:

6/14/2010 Operating Test No.: 2010-01 APPLICANTS SRO-I ;

ATC ;

BOP ;

SRO-U ;

Competencies SCENARIO SCENARIO SCENARIO SCENARIO 1

2 3

4 1

2 3

4 1

2 3

4 1

2 3

4 Interpret/Diagnosis Events and Conditions 1,2 3,4 5,6 7,8 9,

10 1,2 3,4 5,6 7,8 9

1,2 3,4 5,6 7,8 9

1,2 3,4 5,6 7,8 9,

10 11 6,8 9,

10 2,3 4,6 7,8 3,4 6,8 9

1,2 7,8 10 3,4 5,6 7,

10 1,5 6,7 8,9 1,2 5,6 7,8 4,6 7,9 10 11 1,2 3,4 5,6 7,8 9,

10 1,2 3,4 5,6 7,8 9

1,2 3,4 5,6 7,8 9

1,2 3,4 5,6 7,8 9,

10 11 Comply With and Use Procedures (1) 1,2 3,4 5,6 7,8 9,

10 1,2 3,4 5,6 7,8 9

1,2 3,4 5,6 7,8 9

1,2 3,4 5,6 7,8 9,

10 11 2,6 8,9 10 2,3 4,6 7,8 3,4 6,8 9

1,2 7,8 10 1,3 4,5 6,7 10 1,5 6,7 8,9 1,2 5,6 7,8 4,6 7,9 10 11 1,2 3,4 5,6 7,8 9,

10 1,2 3,4 5,6 7,8 9

1,2 3,4 5,6 7,8 9

1,2 3,4 5,6 7,8 9,

10 11 Operate Control Boards (2)

NA NA NA NA 2,6 8,9 10 2,3 4,6 7,8 3,4 6,8 9

1,2 7,8 10 3,6 10 1,5 6,7 8,9 1,2 5,6 7,8 4,6 7,9 10 11 NA NA NA NA Communicate and Interact 1,2 3,4 5,6 7,8 9,

10 1,2 3,4 5,6 7,8 9

1,2 3,4 5,6 7,8 9

1,2 3,4 5,6 7,8 9,

10 11 2,6 8,9 10 2,3 4,6 7,8 3,4 6,8 9

1,2 7,8 10 3,4 5,6 7,

10 1,5 6,7 8,9 1,2 5,6 7,8 4,6 7,9 10 11 1,2 3,4 5,6 7,8 9,

10 1,2 3,4 5,6 7,8 9

1,2 3,4 5,6 7,8 9

1,2 3,4 5,6 7,8 9,

10 11 Demonstrate Supervisory Ability (3) 1,2 3,4 5,6 7,8 9,

10 1,2 3,4 5,6 7,8 9

1,2 3,4 5,6 7,8 9

1,2 3,4 5,6 7,8 9,

10 11 NA NA NA NA NA NA NA NA 1,2 3,4 5,6 7,8 9,

10 1,2 3,4 5,6 7,8 9

1,2 3,4 5,6 7,8 9

1,2 3,4 5,6 7,8 9,

10 11 Comply With and Use Tech. Specs. (3) 3,4 5

1,2 4

4,5 3,4 NA NA NA NA NA NA NA NA 3,4 5

1,2 4

4,5 3,4 Notes:

(1) Includes Technical Specification compliance for an RO.

(2) Optional for an SRO-U.

(3) Only applicable to SROs.

Instructions:

Check the applicant's license type and enter one or more event numbers that will allow the examiners to evaluate every applicable competency for every applicant.

NUREG-1021, Revision 9 Supplement 1 FENOC Facsimile Rev.0

NUREG-1021, Revision 9 Supplement 1 FENOC Facsimile Rev.0 ES-301 Competencies Checklist Form ES-301-6 Facility: Perry Date of Examination:

6/14/2010 Operating Test No.: 2010-01 APPLICANTS SRO-I ;

ATC ;

BOP ;

SRO-U ;

Competencies SCENARIO SCENARIO SCENARIO SCENARIO 5

6 N/A N/A 5

6 N/A N/A 5

6 N/A N/A 5

6 N/A N/A Interpret/Diagnosis Events and Conditions 1,2 3,4 5,6 7,8 9,

10 1,2 3,4 5,6 7

2,3 5,6 7,8 9

10 1,3 4,5 1,4 6,7 9

10 2,3 5,6 7

1,2 3,4 5,6 7,8 9,

10 1,2 3,4 5,6 7

Comply With and Use Procedures (1) 1,2 3,4 5,6 7,8 9,

10 1,2 3,4 5,6 7

2,3 5,6 7,8 9

10 1,3 4,5 1,4 6,7 9

10 2,3 5,6 7

1,2 3,4 5,6 7,8 9,

10 1,2 3,4 5,6 7

Operate Control Boards (2)

NA NA 2,3 5,6 7,8 9

10 1,3 4,5 1,4 6,7 9

10 2,3 5,6 7

NA NA Communicate and Interact 1,2 3,4 5,6 7,8 9,

10 1,2 3,4 5,6 7

2,3 5,6 7,8 9

10 1,3 4,5 1,4 6,7 9

10 2,3 5,6 7

1,2 3,4 5,6 7,8 9,

10 1,2 3,4 5,6 7

Demonstrate Supervisory Ability (3) 1,2 3,4 5,6 7,8 9,

10 1,2 3,4 5,6 7

NA NA NA NA 1,2 3,4 5,6 7,8 9,

10 1,2 3,4 5,6 7

Comply With and Use Tech. Specs. (3) 3 3,4 NA NA NA NA 3

3,4 Notes:

(1) Includes Technical Specification compliance for an RO.

(2) Optional for an SRO-U.

(3) Only applicable to SROs.

Instructions:

Check the applicant's license type and enter one or more event numbers that will allow the examiners to evaluate every applicable competency for every applicant.

ES-401, Rev. 9 BWR Examination Outline Form ES-401-1 Facility: Perry Date of Exam: 06/14/2010 Tier Group RO K/A Category Points SRO-Only Points K

1 K

2 K

3 K

4 K

5 K

6 A

1 A

2 A

3 A

4 G

Total A2 G*

Total

1.

Emergency &

Abnormal Plant Evolutions 1

3 4

3 N/A 4

3 N/A 3

20 4

3 7

2 1

1 1

1 2

1 7

1 2

3 Tier Totals 4

5 4

5 5

4 27 5

5 10

2.

Plant Systems 1

4 3

2 3

2 3

2 2

2 1

2 26 3

2 5

2 1

0 0

1 2

1 2

1 1

2 1

12 0

1 2

3 Tier Totals 5

3 2

4 4

4 4

3 3

3 3

38 4

4 8

3. Generic Knowledge and Abilities Categories 1

2 3

4 1

2 3

4 2

3 2

3 10 2

2 2

1 7

Note: 1. Ensure that at least two topics from every applicable K/A category are sampled within each tier of the RO and SRO-only outlines (i.e., except for one category in Tier 3 of the SRO-only outline, the Tier Totals in each K/A category shall not be less than two).

2. The point total for each group and tier in the proposed outline must match that specified in the table.

The final point total for each group and tier may deviate by +/-1 from that specified in the table based on NRC revisions.

The final RO exam must total 75 points and the SRO-only exam must total 25 points.

3. Systems/evolutions within each group are identified on the associated outline; systems or evolutions that do not apply at the facility should be deleted and justified; operationally important, site-specific systems that are not included on the outline should be added. Refer to Section D.1.b of ES-401 for guidance regarding the elimination of inappropriate K/A statements.
4. Select topics from as many systems and evolutions as possible; sample every system or evolution in the group before selecting a second topic for any system or evolution.
5. Absent a plant-specific priority, only those K/As having an importance rating (IR) of 2.5 or higher shall be selected. Use the RO and SRO ratings for the RO and SRO-only portions, respectively.
6. Select SRO topics for Tiers 1 and 2 from the shaded systems and K/A categories.

7.* The generic (G) K/As in Tiers 1 and 2 shall be selected from Section 2 of the K/A Catalog, but the topics must be relevant to the applicable evolution or system. Refer to Section D.1.b of ES-401 for the appropriate K/As.

8. On the following pages, enter the K/A numbers, a brief description of each topic, the topics importance ratings (IRs) for the applicable license level, and the point totals (#) for each system and category. Enter the group and tier totals for each category in the table above; if fuel handling equipment is sampled in other than Category A2 or G* on the SRO-only exam, enter it on the left side of Column A2 for Tier 2, Group 2 (Note #1 does not apply). Use duplicate pages for RO and SRO-only exams.
9. For Tier 3, select topics from Section 2 of the K/A catalog, and enter the K/A numbers, descriptions, IRs, and point totals (#) on Form ES-401-3. Limit SRO selections to K/As that are linked to 10 CFR 55.43.

ES-401, Rev. 9 BWR Examination Outline Form ES-401-1 S-401 BWR Examination Outline Form ES-401-1 Emergency and Abnormal Plant Evolutions - Tier 1/Group 1 RO E/APE # / Name / Safety Function K

1 K

2 K

3 A

1 A

2 G

K/A Topic(s)

IR 295001 Partial or Complete Loss of Forced Core Flow Circulation / 1 & 4 x

AK1.04 Knowledge of the operational implications of the following concepts as they apply to PARTIAL OR COMPLETE LOSS OF FORCED CORE FLOW CIRCULATION: Limiting cycle oscillation: Plant-Specific 2.5 1

295003 Partial or Complete Loss of AC / 6 x

AK2.01 Knowledge of the interrelations between PARTIAL OR COMPLETE LOSS OF A.C. POWER and the following: Station batteries 3.2 1

295004 Partial or Total Loss of DC Pwr / 6 x

AK3.03 Knowledge of the reasons for the following responses as they apply to PARTIAL OR COMPLETE LOSS OF D.C. POWER: Reactor SCRAM:

3.1 1

295005 Main Turbine Generator Trip / 3 x

AA1.01 Ability to operate and/or monitor the following as they apply to MAIN TURBINE GENERATOR TRIP:

Recirculation system:

3.1 1

295006 SCRAM / 1 295016 Control Room Abandonment / 7 x

AA2.04 Ability to determine and/or interpret the following as they apply to CONTROL ROOM ABANDONMENT:

Suppression pool temperature 3.9 1

295018 Partial or Total Loss of CCW / 8 x

2.4.8 Knowledge of how abnormal operating procedures are used in conjunction with EOPs.

3.8 1

295019 Partial or Total Loss of Inst. Air / 8 x

AA1.04 Ability to operate and/or monitor the following as they apply to PARTIAL OR COMPLETE LOSS OF INSTRUMENT AIR: Service air isolations valves:

3.3 1

295021 Loss of Shutdown Cooling / 4 x

AK2.05 Knowledge of the interrelations between LOSS OF SHUTDOWN COOLING and the following: Fuel pool cooling and cleanup system 2.7 1

295023 Refueling Acc / 8 x

AK3.01 Knowledge of the reasons for the following responses as they apply to REFUELING ACCIDENTS:

Refueling floor evacuation 3.6 1

295024 High Drywell Pressure / 5 x

EA1.10 Ability to operate and/or monitor the following as they apply to HIGH DRYWELL PRESSURE: A.C.

distribution 3.4 1

295025 High Reactor Pressure / 3 x

EA2.03 Ability to determine and/or interpret the following as they apply to HIGH REACTOR PRESSURE:

Suppression pool temperature 3.9 1

295026 Suppression Pool High Water Temp.

/ 5 x

2.2.22 Knowledge of limiting conditions for operations and safety limits.

4.0 1

295027 High Containment Temperature / 5 x

EK1.03 Knowledge of the operational implications of the following concepts as they apply to HIGH CONTAINMENT TEMPERATURE (MARK III CONTAINMENT ONLY):

Containment integrity 3.8 1

295028 High Drywell Temperature / 5 x

EK2.04 Knowledge of the interrelations between HIGH DRYWELL TEMPERATURE and the following: Drywell ventilation 3.6 1

295030 Low Suppression Pool Wtr Lvl / 5 x

EK3.03 Knowledge of the reasons for the following responses as they apply to LOW SUPPRESSION POOL WATER LEVEL: RCIC operation 3.6 1

295031 Reactor Low Water Level / 2 x

EA1.06 Ability to operate and/or monitor the following as they apply to REACTOR LOW WATER LEVEL: Automatic depressurization system 4.4 1

ES-401, Rev. 9 BWR Examination Outline Form ES-401-1 295037 SCRAM Condition Present and Power Above APRM Downscale or Unknown / 1 x

EA2.05 Ability to determine and/or interpret the following as they apply to SCRAM CONDITION PRESENT AND REACTOR POWER ABOVE APRM DOWNSCALE OR UNKNOWN: Control rod position 4.2 1

295038 High Off-site Release Rate / 9 x

2.4.31 Knowledge of annunciator alarms, indications, or response procedures 4.2 1

600000 Plant Fire On Site / 8 x

AK1.02 Knowledge of the operation applications of the following concepts as they apply to Plant Fire On Site:Fire Fighting 2.9 1

700000 Generator Voltage and Electric Grid Disturbances / 6 x

AK2.01 Knowledge of the interrelations between GENERATOR VOLTAGE AND ELECTRIC GRID DISTURBANCES and the following: Motors 3.1 1

K/A Category Totals:

3 4

3 4

3 3

Group Point Total:

20

ES-401, Rev. 9 BWR Examination Outline Form ES-401-1 ES-401 BWR Examination Outline Form ES-401-1 Emergency and Abnormal Plant Evolutions - Tier 1/Group 2 RO E/APE # / Name / Safety Function K

1 K

2 K

3 A

1 A

2 G

K/A Topic(s)

IR 295002 Loss of Main Condenser Vac / 3 295007 High Reactor Pressure / 3 x

AA2.02 Ability to determine and/or interpret the following as they apply to HIGH REACTOR PRESSURE: Reactor power 4.1 1

295008 High Reactor Water Level / 2 295009 Low Reactor Water Level / 2 x

2.4.2 Knowledge of system set points, interlocks and automatic actions associated with EOP entry conditions.

4.5 1

295010 High Drywell Pressure / 5 295011 High Containment Temp / 5 x

AK1.01 Knowledge of the operational implications of the following concepts as they apply to HIGH CONTAINMENT TEMPERATURE (MARK III CONTAINMENT ONLY): Containment pressure: Mark-III 4.0 1

295012 High Drywell Temperature / 5 295013 High Suppression Pool Temp. / 5 295014 Inadvertent Reactivity Addition / 1 x

AK2.01 Knowledge of the interrelations between INADVERTENT REACTIVITY ADDITION and the following: RPS 3.9 1

295015 Incomplete SCRAM / 1 295017 High Off-site Release Rate / 9 295020 Inadvertent Cont. Isolation / 5 & 7 x

AK3.01 Knowledge of the reasons for the following responses as they apply to INADVERTENT CONTAINMENT ISOLATION: Reactor SCRAM 3.8 1

295022 Loss of CRD Pumps / 1 295029 High Suppression Pool Wtr Lvl / 5 x

EA1.02 Ability to operate and/or monitor the following as they apply to HIGH SUPPRESSION POOL WATER LEVEL: HPCS 3.1 1

295032 High Secondary Containment Area Temperature / 5 295033 High Secondary Containment Area Radiation Levels / 9 x

EA2.01 Ability to determine and/or interpret the following as they apply to HIGH SECONDARY CONTAINMENT AREA RADIATION LEVELS: Area radiation levels 3.8 1

295034 Secondary Containment Ventilation High Radiation / 9 295035 Secondary Containment High Differential Pressure / 5 Not Applicable to Perry 295036 Secondary Containment High Sump/Area Water Level / 5 500000 High CTMT Hydrogen Conc. / 5 K/A Category Point Totals:

1 1

1 1

2 1

Group Point Total:

7

ES-401, Rev. 9 BWR Examination Outline Form ES-401-1 ES-401 BWR Examination Outline Form ES-401-1 Plant Systems - Tier 2/Group 1 RO System # / Name K

1 K

2 K

3 K

4 K

5 K

6 A

1 A

2 A

3 A

4 G

K/A Topic(s)

IR 203000 RHR/LPCI: Injection Mode x

K4.09 Knowledge of RHR/LPCI: INJECTION MODE (PLANT SPECIFIC)design feature(s) and/or interlocks which provide for the following:

Surveillance for all operable components 3.1 1

205000 Shutdown Cooling x

K5.03 Knowledge of the operational implications of the following concepts as they apply to SHUTDOWN COOLING SYSTEM (RHR SHUTDOWN COOLING MODE): Heat removal mechanisms 2.8 1

206000 HPCI ot Applicable to Perry 207000 Isolation (Emergency)

Condenser ot Applicable to Perry 215005 OPRM x

K6.04 Knowledge of the effect that a loss or malfunction of the following will have on the OSCILATING POWER RANGE MONITOR/LOCAL POWER RANGE MONITOR SYSTEM: Trip units 3.1 1

209001 LPCS x

A1.03 Ability to predict and/or monitor changes in parameters associated with operating the LOW PRESSURE CORE SPRAY SYSTEM controls including: Reactor water level 3.8 1

209002 HPCS x

A2.10 Ability to (a) predict the impacts of the following on the HIGH PRESSURE CORE SPRAY SYSTEM (HPCS) ; and (b) based on those predictions, use procedures to correct, control, or mitigate the consequences of those abnormal conditions or operations: Valve openings: BWR-5,6 2.7 1

211000 SLC x

x A3.01 Ability to monitor automatic operations of the STANDBY LIQUID CONTROL SYSTEM including: Pump discharge pressure K2.01 Knowledge of electrical power supplies to the following: SBLC pumps 3.5 2.9 2

212000 RPS x

x 2.4.11 Knowledge of abnormal condition procedures.

K1.04 Knowledge of the physical connections and/or cause/effect relationships between REACTOR PROTECTION SYSTEM and the following: A.C. electrical distribution 4.0 3.4 2

215003 IRM x

K2.01 Knowledge of electrical power supplies to the following: IRM channels/detectors 2.5 1

215004 Source Range Monitor x

K3.04 Knowledge of the effect that a loss or malfunction of the SOURCE RANGE MONITOR (SRM) SYSTEM will have on following: Reactor power and indication 3.7 1

215005 APRM / LPRM x

K4.06 Knowledge of AVERAGE POWER RANGE MONITOR/LOCAL POWER RANGE MONITOR SYSTEM design feature(s) and/or interlocks which provide for the following: Effects of detector aging on LPRM/APRM readings 2.6 1

217000 RCIC x

K5.07 Knowledge of the operational implications of the following concepts as they apply to REACTOR CORE ISOLATION COOLING SYSTEM (RCIC): Assist core cooling 3.1 1

218000 ADS x

K6.06 Knowledge of the effect that a loss or malfunction of the following will have on the AUTOMATIC DEPRESSURIZATION SYSTEM:

D.C. power:

3.4 1

ES-401, Rev. 9 BWR Examination Outline Form ES-401-1 223002 PCIS/Nuclear Steam Supply Shutoff x

A1.01 Ability to predict and/or monitor changes in parameters associated with operating the PRIMARY CONTAINMENT ISOLATION SYSTEM/NUCLEAR STEAM SUPPLY SHUT-OFF controls including: System indicating lights and alarms 3.5 1

239002 SRVs x

A2.03 Ability to (a) predict the impacts of the following on the RELIEF/SAFETY VALVES ; and (b) based on those predictions, use procedures to correct, control, or mitigate the consequences of those abnormal conditions or operations:

Stuck open SRV 4.1 1

259002 Reactor Water Level Control x

A3.06 Ability to monitor automatic operations of the REACTOR WATER LEVEL CONTROL SYSTEM including: Reactor water level setpoint setdown following a reactor scram: Plant-Specific 3.0 1

261000 SGTS x

A4.01 Ability to manually operate and/or monitor in the control room: Off-site release levels 3.2 1

262001 AC Electrical Distribution x

2.4.45 Ability to prioritize and interpret the significance of each annunciator or alarm.

4.1 1

262002 UPS (AC/DC) x K1.19 Knowledge of the physical connections and/or cause/effect relationships between UNINTERRUPTABLE POWER SUPPLY (A.C./D.C.) and the following: Power range neutron monitoring system: Plant-Specific 2.9 1

263000 DC Electrical Distribution x

K2.01 Knowledge of electrical power supplies to the following: Major D.C. loads 3.1 1

264000 EDGs x

K3.02 Knowledge of the effect that a loss or malfunction of the EMERGENCY GENERATORS (DIESEL/JET) will have on following: A.C.

electrical distribution 3.9 1

300000 Instrument Air x

x K4.03 Knowledge of (INSTRUMENT AIR SYSTEM) design feature(s) and or interlocks which provide for the following: Securing of IAS upon loss of cooling water K1.05 Knowledge of the connections and / or cause effect relationships between INSTRUMENT AIR SYSTEM and the following:

Main Steam Isolation Valve air 2.8 3.1 2

400000 Component Cooling Water x

x K2.01 Knowledge of electrical power supplies to the following: CCW pumps A1.02 Ability to predict and / or monitor changes in parameters associated with operating the CCWS controls including: CCW temperature 2.9 2.8 2

K/A Category Point Totals:

4 3

2 3

2 3

2 2

2 1

2 Group Point Total:

26

ES-401, Rev. 9 BWR Examination Outline Form ES-401-1 ES-401 BWR Examination Outline Form ES-401-1 Plant Systems - Tier 2/Group 2 RO System # / Name K

1 K

2 K

3 K

4 K

5 K

6 A

1 A

2 A

3 A

4 G

K/A Topic(s)

IR 201001 CRD Hydraulic 201002 RMCS Not Applicable to Perry 201003 Control Rod and Drive Mechanism x

K1.02 Knowledge of the physical connections and/or cause/effect relationships between CONTROL ROD AND DRIVE MECHANISM and the following: Reactor water 2.9 1

201004 RSCS Not Applicable to Perry 201005 RCIS x

K5.09 Knowledge of the operational implications of the following concepts as they apply to ROD CONTROL AND INFORMATION SYSTEM (RCIS): High power setpoints 3.5 1

201006 RWM Not Applicable to Perry 202001 Recirculation 202002 Recirculation Flow Control x

A3.01 Ability to monitor automatic operations of the RECIRCULATION FLOW CONTROL SYSTEM including: Flow control valve operation: BWR-5,6 3.6 1

204000 RWCU 214000 RPIS Not Applicable to Perry 215001 Traversing In-core Probe 215002 RBM Not Applicable to Perry 216000 Nuclear Boiler Inst.

x K4.01 Knowledge of NUCLEAR BOILER INSTRUMENTATION design feature(s) and/or interlocks which provide for the following:

Reading of nuclear boiler parameters outside the control room 3.6 1

219000 RHR/LPCI: Torus/Pool Cooling Mode 223001 Primary CTMT and Aux.

226001 RHR/LPCI: CTMT Spray Mode x

A1.07 Ability to predict and/or monitor changes in parameters associated with operating the RHR/LPCI: CONTAINMENT SPRAY SYSTEM MODE controls including: System pressure 3.1 1

230000 RHR/LPCI: Torus/Pool Spray Mode Not Applicable to Perry 233000 Fuel Pool Cooling/Cleanup x

A4.04 Ability to manually operate and/or monitor in the control room: Pool level 2.9 1

234000 Fuel Handling Equipment 239001 Main and Reheat Steam x

K5.09 Knowledge of the operational implications of the following concepts as they apply to MAIN AND REHEAT STEAM SYSTEM: Decay heat removal 3.4 1

239003 MSIV Leakage Control Not Applicable to Perry 241000 Reactor/Turbine Pressure Regulator x

A1.13 Ability to predict and/or monitor changes in parameters associated with operating the REACTOR/TURBINE PRESSURE REGULATING SYSTEM controls including:

Main turbine speed 2.7 1

245000 Main Turbine Gen. / Aux.

ES-401, Rev. 9 BWR Examination Outline Form ES-401-1 256000 Reactor Condensate 259001 Reactor Feedwater x

A2.05 Ability to (a) predict the impacts of the following on the REACTOR FEEDWATER SYSTEM ; and (b) based on those predictions, use procedures to correct, control, or mitigate the consequences of those abnormal conditions or operations: Loss of applicable plant air systems 3.0 1

268000 Radwaste 271000 Offgas x

A4.02 Ability to manually operate and/or monitor in the control room: System flows 2.9 1

272000 Radiation Monitoring 286000 Fire Protection 288000 Plant Ventilation 290001 Secondary CTMT 290003 Control Room HVAC x

K6.01 Knowledge of the effect that a loss or malfunction of the following will have on the CONTROL ROOM HVAC: Electrical power 2.7 1

290002 Reactor Vessel Internals x

2.2.12 Knowledge of surveillance procedures.

3.7 1

K/A Category Point Totals:

1 0

0 1

2 1

2 1

1 2

1 Group Point Total:

12

ES-401, Rev. 9 BWR Examination Outline Form ES-401-1 cility: Perry Date of Exam: January 2009 Category K/A #

Topic RO SRO-Only IR IR

1. Conduct of Operations 2.1.43 Ability to use procedures to determine the effects on reactivity of plant changes, such as reactor coolant system temperature, secondary plant, fuel depletion, etc.

4.1 1

2.1.44 Knowledge of RO duties in the control room during fuel handling such as responding to alarms from the fuel handling area, communication with the fuel storage facility, systems operated from the control room in support of fueling operations, and supporting instrumentation.

3.9 1

2.1.1 Knowledge of conduct of operations requirements.

4.2 1

2.1.36 Knowledge of procedures and limitations involved in core alterations.

4.1 1

Subtotal 2

2

2. Equipment Control 2.2.37 Ability to determine operability and/or availability of safety related equipment.

3.6 1

2.2.39 Knowledge of less than or equal to one hour Technical Specification action statements for systems.

3.9 1

2.2.42 Ability to recognize system parameters that are entry-level conditions for Technical Specifications.

3.9 1

2.2.23 Ability to track Technical Specifications limiting conditions for operations.

4.6 1

2.2.36 Ability to analyze the effect of maintenance activities, such as degraded power sources, on the status of limiting conditions for operations.

4.2 1

Subtotal 3

2

3. Radiation Control 2.3.13 Knowledge of radiological safety procedures pertaining to licensed operator duties, such as response to radiation monitor alarms, containment entry requirements, fuel handling responsibilities, access to locked high-radiation areas, aligning filters, etc.

3.4 1

2.3.15 Knowledge of radiation monitoring systems, such as fixed radiation monitors and alarms, portable survey instruments, personnel monitoring equipment, etc.

2.9 1

2.3.4 Knowledge of radiation exposure limits under normal or emergency conditions.

3.7 1

2.3.15 Knowledge of radiation monitoring systems, such as fixed radiation monitors and alarms, portable survey instruments, personnel monitoring equipment, etc.

3.1 1

Subtotal 2

2

4. Emergency Procedures / Plan 2.4.14 Knowledge of general guidelines for EOP usage.

3.8 1

2.4.32 Knowledge of operator response to loss of all annunciators.

3.6 1

2.4.43 Knowledge of emergency communications systems and techniques.

3.2 1

2.4.40 Knowledge of SRO responsibilities in emergency plan implementation.

4.5 1

Subtotal 3

1 Tier 3 Point Total 10 7

ES-401, Rev. 9 BWR Examination Outline Form ES-401-1 Facility: Perry Date of Exam: 06/14/2010 Tier Group RO K/A Category Points SRO-Only Points K

1 K

2 K

3 K

4 K

5 K

6 A

1 A

2 A

3 A

4 G

Total A2 G*

Total

1.

Emergency &

Abnormal Plant Evolutions 1

3 4

3 N/A 4

3 N/A 3

20 4

3 7

2 1

1 1

1 2

1 7

1 2

3 Tier Totals 4

5 4

5 5

4 27 5

5 10

2.

Plant Systems 1

4 3

2 3

2 3

2 2

2 1

2 26 3

2 5

2 1

0 0

1 2

1 2

1 1

2 1

12 0

1 2

3 Tier Totals 5

3 2

4 4

4 4

3 3

3 3

38 4

4 8

3. Generic Knowledge and Abilities Categories 1

2 3

4 1

2 3

4 2

3 2

3 10 2

2 2

1 7

Note: 1. Ensure that at least two topics from every applicable K/A category are sampled within each tier of the RO and SRO-only outlines (i.e., except for one category in Tier 3 of the SRO-only outline, the Tier Totals in each K/A category shall not be less than two).

2. The point total for each group and tier in the proposed outline must match that specified in the table. The final point total for each group and tier may deviate by +/-1 from that specified in the table based on NRC revisions. The final RO exam must total 75 points and the SRO-only exam must total 25 points.
3. Systems/evolutions within each group are identified on the associated outline; systems or evolutions that do not apply at the facility should be deleted and justified; operationally important, site-specific systems that are not included on the outline should be added. Refer to Section D.1.b of ES-401 for guidance regarding the elimination of inappropriate K/A statements.
4. Select topics from as many systems and evolutions as possible; sample every system or evolution in the group before selecting a second topic for any system or evolution.
5. Absent a plant-specific priority, only those K/As having an importance rating (IR) of 2.5 or higher shall be selected. Use the RO and SRO ratings for the RO and SRO-only portions, respectively.
6. Select SRO topics for Tiers 1 and 2 from the shaded systems and K/A categories.

7.* The generic (G) K/As in Tiers 1 and 2 shall be selected from Section 2 of the K/A Catalog, but the topics must be relevant to the applicable evolution or system. Refer to Section D.1.b of ES-401 for the appropriate K/As.

8. On the following pages, enter the K/A numbers, a brief description of each topic, the topics importance ratings (IRs) for the applicable license level, and the point totals (#) for each system and category. Enter the group and tier totals for each category in the table above; if fuel handling equipment is sampled in other than Category A2 or G* on the SRO-only exam, enter it on the left side of Column A2 for Tier 2, Group 2 (Note #1 does not apply). Use duplicate pages for RO and SRO-only exams.
9. For Tier 3, select topics from Section 2 of the K/A catalog, and enter the K/A numbers, descriptions, IRs, and point totals

(#) on Form ES-401-3. Limit SRO selections to K/As that are linked to 10 CFR 55.43.

ES-401, Rev. 9 BWR Examination Outline Form ES-401-1 ES-401 BWR Examination Outline Form ES-401-1 Emergency and Abnormal Plant Evolutions - Tier 1/Group 1 SRO E/APE # / Name / Safety Function K

1 K

2 K

3 A

1 A

2 G

K/A Topic(s)

IR 295001 Partial or Complete Loss of Forced Core Flow Circulation / 1 & 4 295003 Partial or Complete Loss of AC / 6 x

AA2.05 Ability to determine and/or interpret the following as they apply to PARTIAL OR COMPLETE LOSS OF A.C. POWER: Whether a partial or complete loss of A.C. power has occurred 4.2 1

295004 Partial or Total Loss of DC Pwr / 6 x

2.4.11 Knowledge of abnormal condition procedures.

4.2 1

295005 Main Turbine Generator Trip / 3 x

AA2.03 Ability to determine and/or interpret the following as they apply to MAIN TURBINE GENERATOR TRIP: Turbine valve position 3.1 1

295006 SCRAM / 1 x

2.4.41 Knowledge of the emergency action level thresholds and classifications.

4.6 1

295016 Control Room Abandonment / 7 295018 Partial or Total Loss of CCW / 8 295019 Partial or Total Loss of Inst. Air / 8 295021 Loss of Shutdown Cooling / 4 295023 Refueling Acc / 8 x

AA2.02 Ability to determine and/or interpret the following as they apply to REFUELING ACCIDENTS:

Fuel pool level 3.7 1

295024 High Drywell Pressure / 5 295025 High Reactor Pressure / 3 295026 Suppression Pool High Water Temp. /

5 x

2.1.19 Ability to use plant computers to evaluate system or component status.

3.8 1

295027 High Containment Temperature / 5 295028 High Drywell Temperature / 5 295030 Low Suppression Pool Wtr Lvl / 5 x

EA2.02 Ability to determine and/or interpret the following as they apply to LOW SUPPRESSION POOL WATER LEVEL: Suppression pool temperature.

3.9 1

295031 Reactor Low Water Level / 2 295037 SCRAM Condition Present and Power Above APRM Downscale or Unknown / 1 295038 High Off-site Release Rate / 9 600000 Plant Fire On Site / 8 700000 Generator Voltage and Electric Disturbances / 6 K/A Category Totals:

4 3

Group Point Total:

7

ES-401, Rev. 9 BWR Examination Outline Form ES-401-1 S-401 BWR Examination Outline Form ES-401-1 Emergency and Abnormal Plant Evolutions - Tier 1/Group 2 SRO E/APE # / Name / Safety Function K

1 K

2 K

3 A

1 A

2 G

K/A Topic(s)

IR 295002 Loss of Main Condenser Vac / 3 295007 High Reactor Pressure / 3 295008 High Reactor Water Level / 2 295009 Low Reactor Water Level / 2 295010 High Drywell Pressure / 5 x

2.4.18 Knowledge of the specific bases for EOPs.

4.0 1

295011 High Containment Temp / 5 295012 High Drywell Temperature / 5 x

AA2.01 Ability to determine and/or interpret the following as they apply to HIGH DRYWELL TEMPERATURE:

Drywell temperature.

3.9 1

295013 High Suppression Pool Temp. / 5 295014 Inadvertent Reactivity Addition / 1 295015 Incomplete SCRAM / 1 295017 High Off-site Release Rate / 9 295020 Inadvertent Cont. Isolation / 5 & 7 295022 Loss of CRD Pumps / 1 295029 High Suppression Pool Wtr Lvl / 5 x

2.1.32 Ability to explain and apply system limits and precautions.

4.0 1

295032 High Secondary Containment Area Temperature / 5 295033 High Secondary Containment Area Radiation Levels / 9 295034 Secondary Containment Ventilation High Radiation / 9 295035 Secondary Containment High Differential Pressure / 5 ot Applicable to Perry 295036 Secondary Containment High Sump/Area Water Level / 5 500000 High Containment Hydrogen Conc. /

5 K/A Category Point Totals:

1 2

Group Point Total:

3

ES-401, Rev. 9 BWR Examination Outline Form ES-401-1 ES-401 BWR Examination Outline Form ES-401-1 Plant Systems - Tier 2/Group 1 SRO System # / Name K

1 K

2 K

3 K

4 K

5 K

6 A

1 A

2 A

3 A

4 G

K/A Topic(s)

IR 203000 RHR/LPCI: Injection Mode 205000 Shutdown Cooling 206000 HPCI Not Applicable to Perry 207000 Isolation (Emergency)

Condenser Not Applicable to Perry 209001 LPCS 209002 HPCS 211000 SLC 212000 RPS 215003 IRM x

A2.05 Faulty or erratic operation of detectors/system 3.5 1

215004 Source Range Monitor 215005 APRM / LPRM 215005 OPRM 217000 RCIC x

2.1.27 Knowledge of system purpose and/or function.

4.0 1

218000 ADS 223002 PCIS/Nuclear Steam Supply Shutoff x

A2.08 Ability to (a) predict the impacts of the following on the PRIMARY CONTAINMENT ISOLATION SYSTEM/NUCLEAR STEAM SUPPLY SHUT-OFF ; and (b) based on those predictions, use procedures to correct, control, or mitigate the consequences of those abnormal conditions or operations: Surveillance testing 3.1 1

239002 SRVs x

2.4.46 Ability to verify that the alarms are consistent with the plant conditions.

4.2 1

259002 Reactor Water Level Control 261000 SGTS x

A2.07 Ability to (a) predict the impacts of the following on the STANDBY GAS TREATMENT SYSTEM ; and (b) based on those predictions, use procedures to correct, control, or mitigate the consequences of those abnormal conditions or operations: A.C. electrical failure 2.8 1

262001 AC Electrical Distribution 262002 UPS (AC/DC) 263000 DC Electrical Distribution 264000 EDGs 300000 Instrument Air 400000 Component Cooling Water K/A Category Point Totals:

3 2

Group Point Total:

5

ES-401, Rev. 9 BWR Examination Outline Form ES-401-1

-401 BWR Examination Outline Form ES-401-1 Plant Systems - Tier 2/Group 2 SRO System # / Name K

1 K

2 K

3 K

4 K

5 K

6 A

1 A

2 A

3 A

4 G

K/A Topic(s)

IR 201001 CRD Hydraulic 201002 RMCS Not Applicable to Perry 201003 Control Rod and Drive Mechanism 201004 RSCS Not Applicable to Perry 201005 RCIS 201006 RWM Not Applicable to Perry 202001 Recirculation 202002 Recirculation Flow Control x

2.1.32 Ability to explain and apply system limits and precautions.

4.0 1

204000 RWCU x

A2.12 Ability to (a) predict the impacts of the following on the REACTOR WATER CLEANUP SYSTEM ; and (b) based on those predictions, use procedures to correct, control, or mitigate the consequences of those abnormal conditions or operations: Excessive drain flow rates 2.8 1

214000 RPIS Not Applicable to Perry 215001 Traversing In-core Probe 215002 RBM Not Applicable to Perry 216000 Nuclear Boiler Inst.

x 2.1.9 Ability to direct personnel activities inside the control room.

4.5 1

219000 RHR/LPCI: Torus/Pool Cooling Mode 223001 Primary CTMT and Aux.

226001 RHR/LPCI: CTMT Spray Mode 230000 RHR/LPCI: Torus/Pool Spray Mode Not Applicable to Perry 233000 Fuel Pool Cooling/Cleanup 234000 Fuel Handling Equipment 239001 Main and Reheat Steam 239003 MSIV Leakage Control Not Applicable to Perry 241000 Reactor/Turbine Pressure Regulator 245000 Main Turbine Gen. / Aux.

256000 Reactor Condensate 259001 Reactor Feedwater 268000 Radwaste 271000 Offgas 272000 Radiation Monitoring 286000 Fire Protection

ES-401, Rev. 9 BWR Examination Outline Form ES-401-1 288000 Plant Ventilation 290001 Secondary CTMT 290003 Control Room HVAC 290002 Reactor Vessel Internals K/A Category Point Totals:

1 2

Group Point Total:

3

ES-401, Rev. 9 Generic Knowledge and Abilities Outline (Tier 3)

Form ES-401-3 NUREG 1021, Rev. 9 Page 1 of 1 FENOC Facsimile Facility: Perry Date of Exam: January 2009 Category K/A #

Topic RO SRO-Only IR IR

1. Conduct of Operations 2.1.43 Ability to use procedures to determine the effects on reactivity of plant changes, such as reactor coolant system temperature, secondary plant, fuel depletion, etc.

4.1 1

2.1.44 Knowledge of RO duties in the control room during fuel handling such as responding to alarms from the fuel handling area, communication with the fuel storage facility, systems operated from the control room in support of fueling operations, and supporting instrumentation.

3.9 1

2.1.1 Knowledge of conduct of operations requirements.

4.2 1

2.1.36 Knowledge of procedures and limitations involved in core alterations.

4.1 1

Subtotal 2

2

2. Equipment Control 2.2.37 Ability to determine operability and/or availability of safety related equipment.

3.6 1

2.2.39 Knowledge of less than or equal to one hour Technical Specification action statements for systems.

3.9 1

2.2.42 Ability to recognize system parameters that are entry-level conditions for Technical Specifications.

3.9 1

2.2.23 Ability to track Technical Specifications limiting conditions for operations.

4.6 1

2.2.36 Ability to analyze the effect of maintenance activities, such as degraded power sources, on the status of limiting conditions for operations.

4.2 1

Subtotal 3

2

3. Radiation Control 2.3.13 Knowledge of radiological safety procedures pertaining to licensed operator duties, such as response to radiation monitor alarms, containment entry requirements, fuel handling responsibilities, access to locked high-radiation areas, aligning filters, etc.

3.4 1

2.3.15 Knowledge of radiation monitoring systems, such as fixed radiation monitors and alarms, portable survey instruments, personnel monitoring equipment, etc.

2.9 1

2.3.4 Knowledge of radiation exposure limits under normal or emergency conditions.

3.7 1

2.3.15 Knowledge of radiation monitoring systems, such as fixed radiation monitors and alarms, portable survey instruments, personnel monitoring equipment, etc.

3.1 1

Subtotal 2

2

4. Emergency Procedures / Plan 2.4.14 Knowledge of general guidelines for EOP usage.

3.8 1

2.4.32 Knowledge of operator response to loss of all annunciators.

3.6 1

2.4.43 Knowledge of emergency communications systems and techniques.

3.2 1

2.4.40 Knowledge of SRO responsibilities in emergency plan implementation.

4.5 1

Subtotal 3

1 Tier 3 Point Total 10 7

ES-401, Rev. 9 Record of Rejected K/As Form ES-401-4 Tier / Group Randomly Selected K/A Reason for Rejection 1/1 RO 295038 2.2.38 Was unable to write a question for selected K/A (2.2.38 Knowledge of conditions and limitations in the facility license). Randomly selected 295038 2.4.31.

1/1/RO 700000 AK2.06 Was unable to write a discriminating question for selected K/A (700000 AK2.06 Reactor power). Randomly selected K/A 700000 AK2.01 Motors 2/1/RO 207000 K2.06 Selected K/A was on Isolation Condenser system, not applicable to Perry. Randomly selected K/A 215005 (OPRM) K6.04 Trip units 2/1/RO 215004 K3.01 Was unable to write a discriminating question for selected K/A (K3.01 RPS). Randomly selected K/A K3.04 (Reactor power and indication) 2/1 RO 218000 K6.05 Selected K/A was covered under 295031 EA1.06 (question 26). Randomly selected K/A 218000 K6.06 2/1/RO 259002 A3.08 Selected K/A was on FWCI system, not applicable to Perry. Randomly selected K/A 259002 A3.06 (Reactor water level setpoint setdown following a reactor scram) 2/1/RO 262002 K1.15 Selected K/A was on Stack gas monitors powered from a UPS system, not applicable to Perry. Randomly selected K/A 262002 K1.19 (Power range neutron monitoring system) 2/1/RO 300000 K5.13 Was unable to write a discriminating question for selected K/A (K5.13 Filters). Randomly selected K/A 300000 K1.05 (Main Steam Isolation Valve air) 2/1/RO 400000 A1.04 Selected K/A was covered under Audit Exam (question 53). Randomly selected K/A 400000 A1.02 2/2/RO 201002 2.2.40 Selected K/A was on RMCS system, not applicable to Perry. Randomly selected K/A 233000 A4.04 (Ability to... in the control room: Pool level) 2/2/RO 215001 2.4.31 Selected K/A was on Alarms and indications for the Traversing In-Core Probe, Alarms and indications not applicable to Perry. Randomly selected K/A 226001 A1.07 (CONTAINMENT SPRAY: System pressure) 2/2/RO 239001 K5.07 Selected K/A was on Hydraulic operated MSIV's, not applicable to Perry. Randomly selected K/A 239001 K5.09 (Decay heat removal) 2/2/RO 239003 K6.01 Selected K/A was on MSIV Leakage Control system, not applicable to Perry. Randomly selected K/A 202002 A3.01 (Flow control valve operation) 2/2/RO 241000 A1.24 Was unable to write a discriminating question for selected K/A. Randomly selected K/A 241000 A1.13 (Main turbine speed) 2/2/RO 268000 A1.01 Was unable to write a discriminating question for selected K/A (Radwaste). Randomly selected K/A 290003 K6.01 (CONTROL ROOM HVAC: Electrical power) 3/SRO 2.2.1 Was unable to write a question for selected K/A (SROs operating controls). Randomly selected K/A 2.2.23 1/1/SRO 295004 2.1.19 Was unable to write a SRO level question for selected K/A. Randomly selected K/A 295004 2.4.11 (Knowledge of abnormal condition procedures) (Dell McNeil concurred) 1/1SRO 295030 EA2.04 Selected K/A was on Drywell/ suppression chamber, not applicable to Perry. Randomly selected K/A 295030 EA2.02 (Suppression pool temperature) 1/2/SRO 500000 2.4.4 Was unable to write a SRO level question for selected K/A. Keith Walton (USNRC) concurred with rejecting K/A. Randomly selected K/A 295029 2.1.32 2/1/SRO 207000A2.03 Selected K/A was on Isolation Condenser system, not applicable to Perry. Randomly selected K/A 215003 A2.05 (Faulty or erratic operation of detectors/system) 2/2/SRO 201002 2.4.50 Selected K/A was on RMCS system, not applicable to Perry. Randomly selected K/A 202002 2.1.32 2/2/SRO 204000 A2.02 Selected K/A was Pressure control valve failure: LP-RWCU - not applicable to Perry.

Randomly selected A2.12

Appendix D, Rev. 9 Scenario Outline Form ES-D-1 Facility: Perry Scenario No.: 1 - 100%

Op-Test No.: 2010-01 Examiners:

Operators:

Initial Conditions:

Reactor Power 100%. BOL Pull Sheets, Rods @ Step 64.

IOI-3 Step 4.5 is complete.

ESW B is running to support vibration testing. HPCS ESW running to support HPCS run.

RFBP A is OOS for motor replacement. Control Rod 34-55 is inserted.

A severe thunderstorm watch has been issued for Lake, Geauga, & Ashtabula counties.

Green Risk.

Turnover:

Start HPCS in CST to CST for SVI. Personnel have been briefed and are on station to support field activities. When SCC request lower power to 95% per IOI-3 Power Maneuvering.

Event No.

Malf. No.

Event Type*

Event Description 1

N-BOP/SRO Start HPCS for SVI (CST CST) 2 R-ATC N-SRO Lower power with flow 3

cp02_1e22c0001 C-BOP/SRO HPCS pump trips on over-current SRO Tech Spec 3.5.1 4

cb01_1p45c0001b C-BOP/SRO ESW B pump trips - discharge valve fails to auto close SRO Tech Spec 3.7.1 & 3.8.1 5

pt01_1c34n0004c I-BOP/SRO C34N004C fails high SRO ORM 6.2.13 6

pt01_1c34n0004b M-All Loss of feedwater EOP-1 RPV Control & EOP-1A (ATWS) 7 mv06_1e51f0013 C-BOP/SRO RCIC Injection valve fails closed (loss of all HP injection)

Trip RCIC on min flow due to injection valve failure 8

cb03_1b33s101b cb03_1b33s105b cb03_1b33s106b C-ATC/SRO Reactor Recirc pump B fails to trip from fast speed 9

TC04A C-ATC/SRO Bypass valve #1 fails open 10 M-All Emergency Depressurize EOP-4-2 on inability to maintain > -25 (N)ormal, (R)eactivity, (I)nstrument, (C)omponent, (M)ajor

Appendix D, Rev. 9 Scenario Outline Form ES-D-1 Facility:

Perry Scenario No.: 2 - 11%

Op-Test No.: 2010-01 Examiners:

Operators:

Initial Conditions:

Reactor Power 11%. BOL Pull Sheets, Rods @ Step 31, Gang 32 at Position 28.

Power ascension is in progress. IOI-3 Step 4.1, step 1.

Main Turbine is at 1800 RPM Hotwell Pump C is tagged out for oil leak. IRM D is INOP and bypassed due to drawer failure during startup.

Green Risk.

Turnover: Shift AEGTS fans from A to B for run time. Continue with power ascension and synchronize the generator top the grid.

Event No.

Malf. No.

Event Type*

Event Description 1

N-BOP/SRO Shift AEGTS fans from A to B SRO Tech Specs 3.6.4.3 2

NM04H I-ATC/SRO APRM H fails downscale - rod block - Bypass APRM H SRO Tech Spec 3.3.1.1 3

R-ATC N-SRO Pull Control rods to get 2 1/2 bypass valves open 4

RD01R2635 C-ATC/SRO Control Rod 26-35 stuck @ position 12 - will move to position 20 then stick again. ONI-C11-1 SRO Tech Spec 3.1.3 for Stuck Withdrawn Control Rod 5

cp02_1p44c0001b C-BOP/SRO Loss of TBCC B pump 6

1B21N00678A M-All Both Reactor Recirc pumps trip 7

RD15 M-All ATWS, ONI-C71-1 Reactor Scram 8

RD16 M-All Scram discharge Volume leak in containment - press 9

mv06_1e12f0537a C-BOP/SRO Containment Spray A will not initiate, transition to Containment Spray B or Emergency Depressurize (N)ormal, (R)eactivity, (I)nstrument, (C)omponent, (M)ajor

Appendix D, Rev. 9 Scenario Outline Form ES-D-1 Facility:

Perry Scenario No.: 3 - 3%

Op-Test No.: 2010-01 Examiners:

Operators:

Initial Conditions: Reactor Power 3%, BOL Pull Sheets, Rods @ Step 24 Gang 37 at Position 12.

Power ascension in progress to make Mode change. HW Pump B is in Standby & HW Pump C is Emergency Start pump. IOI-2 Hot Startup Section 4.7.

RFBP B and NCC Pump C are Out of Service.

APRM A is bypassed for I&C SVI-C51-T0027A.

Due to a problem with resetting the main turbine, warming the turbine has not yet commenced.

Reactor Engineer is available in the Control Room.

Turnover:

Continue Power Ascension per IOI-2 Hot Startup. Place Circulating Water Pump C in service per SOI-N71 Circulating Water System. Hot Water Inlet MOVs 5 and 10 are closed. NLO has been briefed for Circ Water Pump start and is on station. Rx Engineer concurs with Gang Mode and Continuous Rod Withdrawal Event No.

Malf. No.

Event Type*

Event Description 1

R ATC N/SRO Pull Control Rods per IOI-2 for Transfer to Run 2

N-BOP/SRO Place Circulating Water Pump C in service 3

RP01A C-All RPS Bus A EPA Failure, Loss of RPS Bus A SRO ONI-C71-2 Loss of RPS Bus, ORM 6.3.1.5 4

NM02G I-ATC IRM G Fails upscale, Bypass IRM G, Range IRMs and Reset 1/2 Scram SRO Tech Spec 3.3.1.1(IRM G) and ORM 6.2.3 5

PC04 M-All Suppression Pool Leak, EOP-3 Secondary Containment Control and EOP-2 Containment Control 6

ZD1E22F0004 C (BOP)

HPCS Injection valve fails open. Override HPCS Pump to off 7

cb04_1p42c0001a C (BOP)

ECC A pump fails to auto start - manually start ECC pump 8

M-All Emergency Depressurize EOP-4-2, on lowering Pool Level (N)ormal, (R)eactivity, (I)nstrument, (C)omponent, (M)ajor