ES-401 Site-Specific RO Written Examination Cover Sheet Form ES-401-7 U.S. Nuclear Regulatory Commission Site-Specific RO Written Examination Applicant Information Name:

Date: 12/

/09 Facility/Unit: St. Lucie Plant Region:

I o II [g] III 0 IV D Reactor Type: W D CE [g] BW 0 GE 0 Start Time:

Finish Time:

Instructions Use the answer sheets provided to document your answers. Staple this cover sheet on top of the answer sheets. To pass the examination, you must achieve a final grade of at least 80.00 percent. Examination papers will be collected 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> after the examination begins.

Applicant Certification All work done on this examination is my own. I have neither given nor received aid.

AppJicant's Signature Results Examination Value Points Applicant's Score Points Applicant's Grade Percent

PSL HLC 19 NRC EXAM Question 1 Which ONE of the following Safety Function(s) in 1/2-EOP-01, "SPTAs", can be FULLY evaluated by using the Qualified System Parameter Display System (QSPDS)?

A. ONLY RCS Pressure Control B. ONLY Core Heat Removal C. Core Heat Removal & RCS Heat Removal D. RCS Pressure Control & RCS Heat Removal 1

PSL HLC 19 NRC EXAM Question 2 Given the following conditions on Unit 1:

1-EOP-03, "LOCAl! is being implemented Pressurizer Pressure 900 psia and slowly lowering.

T HOT is 508°F and slowly lowering.

Pressurizer Level is 70% and slowly rising.

Rep. CET 515°F and slowly lowering.

Both Steam Generators are 25% Narrow Range and rising with total AFW flow of 350 gpm.

Both Steam Generator pressures are 660 psia slowly lowering.

ECCS flow is 650 gpm.

Containment Temperature is 185°F and slowly lowering.

Which ONE of the following states the strategy that should be implemented?

Cool down and ____ _

A. throttle ECCS flow to allow Pressurizer level to lower to meet the Inventory Control Safety Function.

B. ensure 1-EOP-99, Figure 2 is being maintained. Subcooling requirements take precedence over Pressurizer level.

C. depressurize to maximize ECCS flow. Maximizing ECCS flow takes precedence over Pressurizer level and subcooling.

D. throttle ECCS flow as Pressurizer level approaches 100%. Preventing Pressurizer level from going solid takes precedence over subcooling requirements.

2

PSL HLC 19 NRC EXAM Question 3 A Loss of Coolant Accident has occurred on Unit 1 with the following conditions:

ReS T-hot is 512°F.

Pressurizer Pressure is 1120 psia.

Which ONE of the following describes the RCP operating strategy and the reason for such?

Trip:

A. ALL Rep's to enhance RCS heat removal.

B. ALL RCP's due to loss of RCP NPSH.

C. ONE RCP in each loop to enhance RCS heat removal.

D. ONE Rep due to loss of ReS NPSH.

3

PSL HLC 19 NRC EXAM Question 4 Unit 1 is operating at 100% power when the following events occur:

ONE of the CCW radiation monitors has just gone into alarm.

CCW Surge Tank level is 80% and rising.

DCS Computer point 33x194_A 181 RCP CL Tube Lk Vlv Cis I Pwr FA is in alarm.

RCP 181 lower seal temperature is increasing.

HCV-14-11 81, "Seal Cooler Isolation Valve", indicates closed.

1) Which ONE of the following has closed HCV-14-11 81?
2) What actions should the crew take?

A. 1) High radiation in the CCW system.

2) Make preparations to shut down the unit and trip the 181 RCP.
8. 1) High radiation in the CCW system.
2) Override open HCV-14-1181. THEN perform a down power. Trip the 181 RCP when the Unit is shut down.

C. 1) High seal cooler outlet temperature.

2) Make preparations to shut down the unit and trip the 181 RCP.

D. 1) High seal cooler outlet temperature.

2) Override open HCV-14-1181. THEN perform a down power. Trip the 181 RCP when the Unit is shut down.

4

PSL HLC 19 NRC EXAM Question 5 A RCS leak is in progress on Unit 1. Given the following at time 12:30:

50% power steady state.

V2504, RWT to Charging pumps, is closed and racked out.

Pressurizer Level is 58% and steady.

Letdown Flow is 29 gpm.

ALL Charging Pumps are running.

VCT Level is 40% and lowering.

RCP 1A1 CBO: 1.4 gpm RCP 1 B1 CBO: 1.4 gpm RCP 1 A2 CBO: 1.4 gpm RCP 1 B2 CBO:. 1.3 gpm Which ONE of the following would be the expected time that a loss of Charging would occur?

(Assume NO Operator actions are taken.)

A. 12:37 - 12:38 B. 12:39 - 12:40 C.12:41 - 12:42 D. 12:53 - 12:54 5

PSL HLC 19 NRC EXAM Question 6 Unit 2 is in 2-NOP-01.04, "RCS Reduced Inventory and Mid-Loop Operation" with the following:

RCS Level is at 29 feet 10 inches.

Reactor Vessel Head is installed.

Nozzle dams are being installed.

1) Which SOC Loop will be operating and:
2) If loss of SOC were to occur, which of the following conditions could result in RCS pressurization and loss of inventory?

A. 1) 2A SOC Loop

2) Hot leg nozzle dams installed prior to cold leg nozzle dams being installed.

B. 1) 2B SOC Loop

2) Hot leg nozzle dams installed prior to cold leg nozzle dams being installed.

C. 1) 2A SOC Loop

2) Cold leg nozzle dams installed prior to hot leg nozzle dams being installed.

O. 1) 2B SOC Loop

2) Cold leg nozzle dams installed prior to hot leg nozzle dams being installed.

6

PSL HLC 19 NRC EXAM Question 7 ONLY on _(1) __ will MV-14-18, CCW Header A Supply to Fuel Pool HX, receive a SIAS close signal to ensure (2) __.

A. 1) Unit 1;

2) adequate CCW Flow is available to essential ESF components during a Design Basis Accident (DBA)..

B. 1) Unit 1;

2) train separation in the event of a Design Basis Accident (DBA).

C. 1) Unit 2;

2) adequate CCW Flow is available to essential ESF components during a Design Basis Accident (DBA)..

D. 1) Unit 2;

2) train separation in the event of a Design Basis Accident (DBA).

7

PSL HLC 19 NRC EXAM Question 8 Unit 1 is operating at 100% power when the selected channel L T -111 OX, "Pressurizer Level Transmitter" fails LOW.

What will be the FIRST effect this failure has on the following Actual Pressurizer Parameters?

(Assume NO operator actions are taken.)

Pressurizer Pressure Saturation Temperature A. Rising Rising B. Lowering Lowering C. Lowering Rising D. Rising Lowering 8

PSL HLC 19 NRC EXAM Question 9 Unit 2 is in 2-EOP-04, "Steam Generator Tube Rupture", with a Loss Of Offsite Power (LOOP).

The 2B S/G has been isolated and the "close" fuses for RCPs 2B1 & 2B2 have been removed.

Which ONE of the following states the reason for removal of the "close" fuses?

To prevent an inadvertent RCP start, upon power restoration, that could result in:

A. RCP seal failure.

B. a positive reactivity event.

C. operating RCP's outside of NPSH requirements.

D. a pressure spike that could lift the secondary safeties.

9

PSL HLC 19 NRC EXAM Question 10 Unit 1 was operating at 100% power when it experienced a Station Blackout (SBO).

Given the following events and conditions:

Unit 2 has had a Loss Of Offsite Power (LOOP).

2B EDG failed to start and can NOT be started.

2A EDG is supplying the 2A3 4.16 KVAC bus.

2AB 4.16 KVAC bus is lined up from 2A3 4.16 KVAC bus.

BOTH Unit 1 & 2 SBO Cross Tie Breakers are open.

ALL associated Normal/Isolate Switches are in Normal.

Based on these plant events and conditions:

1) Which of the following are the expected indications of the SBO Crosstie Breaker Permissive Lights in BOTH Control Rooms?
2) Which of the following are the manipulations needed to restore power to the 1 AB 4.16 KVAC bus?

A. 1) Unit 1 ON Unit 2 OFF

2) Close Unit 1 SBO Cross Tie Breaker prior to closing Unit 2 SBO Cross Tie Breaker.

B. 1) Unit 1 ON Unit 2 OFF

2) Close Unit 2 SBO Cross Tie Breaker prior to closing Unit 1 SBO Cross Tie Breaker.

C. 1) Unit 1 OFF Unit 2 ON

2) Close Unit 1 SBO Cross Tie Breaker prior to closing Unit 2 SBO Cross Tie Breaker.

D. 1) Unit 1 OFF Unit 2 ON

2) Close Unit 2 SBO Cross Tie Breaker prior to closing Unit 1 SBO Cross Tie Breaker.

10

PSL HLC 19 NRC EXAM Question 11 While performing 2-GOP-305, "Reactor Plant Cooldown - Hot Standby To Cold Shutdown", with SIAS blocked a Loss Of Offsite Power (LOOP) occurred with the failure of BOTH Diesel Generators to start.

Plant conditions indicate:

Pressurizer pressure is 1520 psia and lowering.

T-hot is 548°F and steady.

T-cold is 542°F and steady.

Rep-Cet is 552°F and steady.

A and B ADV's are 40% open Pressurizer Level is 32% and lowering.

BOTH SfG Levels are 24% Narrow Range and constant with 2C AFW flow rate of 150 gpm per SfG.

RVLMS sensors 1-8 are covered.

Based on the present plant conditions, which ONE of the following:

1) Procedures will be FULLY implemented?
2) Is the current method of heat removal and which parameter, if increased, would have the GREATEST impact on enhancing natural circulation?

A. 1) 2-0120039, "NATURAL CIRCULATION COOLDOWN".

2) Single Phase Natural Circulation. Increasing both ADV's output to 80%.

B. 1) 2-0120039, "NATURAL CIRCULATION COOLDOWN".

2) Two Phase Natural Circulation. Increasing AFW flow to 200 gpm per SfG C. 1) 2-0NP-01.01, "PLANT CONDITION 1 S/G HEAT REMOVAL L TOP NOT IN EFFECT".
2) Single Phase Natural Circulation. Increasing both ADV's output to 80%.

D. 1) 2-0NP-01.01, "PLANT CONDITION 1 S/G HEAT REMOVAL L TOP NOT IN EFFECT".

2) Two Phase Natural Circulation. Increasing AFW flow to 200 gpm per S/G.

11

PSL HLC 19 NRC EXAM Question 12 Unit 1 is operating at 100% when a loss of the 120 VAC Instrument Bus 1 MA occurs.

Which ONE of the following Control Room alarms would NOT be expected?

A. Q-191B S/G PRESS MSIS CHANNEL TRIP B. Q-16 CNTMT RAD HIGH CIS CHANNEL TRIP C. R-10 ENGINEERED SAFEGUARDS ATI FAULT D. R-11 CNTMT PRESS HIGH CSAS CHANNEL TRIP 12

PSL HLC 19 NRC EXAM Question 13 The 1A Emergency Diesel Generator (EDG) is running fully loaded during a surveillance. A loss of DC control power to the 1 A EDG occurs.

Which ONE of the following is the method to manually trip the EDG for the above conditions?

A. Depressing the engine mounted emergency trip pushbutton.

B. Depressing the emergency trip pushbutton on the Control Room RTGB.

C. Manually actuating the overspeed trip (OST) mechanism.

D. Manually actuating the Lockout Relay.

13

PSL HLC 19 NRC EXAM Question 14 Unit 2 is at 100% power with 2C ICW pump on an Equipment Clearance.

The following alarm is received:

2AICW PUMP OVLD/TRIP E6 2-0640030, "Intake Cooling Water System", is being implemented. ALL attempts to restart 2A ICW pump are unsuccessful.

Prior to reducing turbine load which ONE of the following will have the GREATEST impact in maintaining available heat removal capacity?

A. Reduce Main Generator MVARs.

B. Place BOTH Lube Oil Coolers in service.

C. Ensure the Open Blowdown Heat Exchanger is aligned to the unaffected header.

D. Close the "TCW Heat Exchanger cross-tie", SB13139, and open the 'A' "TCW Heat Exchanger shell side isolation valve", SB13147, to maximize TCW Cooling.

14

PSL HLC 19 NRC EXAM Question 15 Unit 2 Control Room is performing an up power per 2-GOP-201, "Reactor Plant Startup", from 70% to 100% power with the following plant conditions:

Dilution flow: 20gpm Turbine Load rate: 2.5 MW/min 2A & 2B Charging Pumps are running.

The following alarm is received in the Unit 2 Control Room:

INSTR AIR PRESSURE HIGH/LOW F5 If Instrument Air continues to lower which ONE of the following responses (assuming NO Operator actions are taken) are expected?

T-avg VeT Level A.

Lowering Rising B.

Rising Lowering C.

Rising Rising D.

Lowering Lowering 15

PSL HLC 19 NRC EXAM Question 16 Unit 1 is operating with the following plant conditions:

Main Generator is 60 MVARS in the Lag.

Main Generator Gross MWs are 895.

The Unit is only able to maintain 45 psig Hydrogen pressure.

1) What would the equipment concern be if an electrical grid disturbance resulted in adding 290 Leading MVARs?
2) What actions could the Control Board operator take to reduce the equipment concern?

A. 1) rotor overheating

2) Coordinate with Unit 2 and Raise output of Voltage Regulator.

B. 1) stator overheating

2) Coordinate with Unit 2 and Raise output of Voltage Regulator.

C. 1) rotor overheating

2) Coordinate with Unit 2 and Lower output on the Voltage Regulator.

D. 1) stator overheating

2) Coordinate with Unit 2 and Lower output on Voltage Regulator.

16

PSL HLC 19 NRC EXAM Question 17 Unit 2 was at 100% power when a Loss Of Offsite Power (LOOP) has occurred. Following the Reactor trip a steam leak occurs inside the Containment on the 2A S/G. The following conditions now exist:

2A S/G is 590 psia.

2B S/G is 615 psia.

Containment pressure is 3.1 psig.

"Main Steam Isolation Valve", HCV-08-1A, is CLOSED.

"Main Steam Isolation Valve", HCV-08-1 B, is OPEN.

Which ONE of the following identifies the status of Main Steam Isolation Signal (MSIS) and the Main Steam Isolation Valves?

1) MSIS Channel 'A' has actuated on:
2) HCV-08-1 B:

A. 1) low 2A S/G pressure and has closed HCV-08-1A.

2) will NOT close until 2B S/G pressure reaches MSIS Channel 'B' setpoint.

B. 1) low 2A S/G pressure and has closed HCV-08-1A.

2) should have also closed.

C. 1) high Containment pressure AND low 2A S/G pressure closing HCV-08-1 A.

2) should have also closed.

D. 1) high Containment pressure AND low 2A S/G pressure closing HCV-08-1A.

2) is open due to failure of MSIS Channel 'B' to actuate.

17

PSL HLC 19 NRC EXAM Question 18 Unit 1 is 60% power with BOTH 1 A & 1 B MFW Pumps running when an inadvertent Channel 'A' Main Steam Isolation Signal (MSIS) occurs resulting in a Reactor trip.

Which ONE of the following describes restoration of S/G Levels following the Reactor trip?

A. Manual AF AS 1 & 2 is required to restore BOTH 1 A & 1 B S/G Levels.

B. MFW Pump 1 B will restore 1 B S/G Level.

Auxiliary Feedwater will automatically restore 1 A S/G level.

C. Auxiliary Feedwater will automatically restore 1 B S/G Level.

Manual AFAS-1 is required to restore 1A S/G Level.

D. Auxiliary Feedwater will automatically restore BOTH 1A & 1 B S/G Levels.

18

PSL HLC 19 NRC EXAM Question 19 Given the following on Unit 2:

  • 100% power steady state, MOC
  • Control Element Assembly (CEA) # 2 of Shutdown Group A drops to the bottom of the core.
  • ALL required IMMEDIATE operator actions of 2-0110030, "CEA Off-Normal Operation and Re-alignment", have been taken.

The interlock that is required to be bypassed to withdraw CEA # 2 is ____ and the design basis for the interlock is _____ _

A. 1) CEA Motion Inhibit.

2) to prevent CEA withdrawal or insertion when abnormal CEA alignment is detected.

B. 1) Shutdown Group Interlock Bypass.

2) to prevent CEA withdrawal or insertion when abnormal CEA alignment is detected.

C. 1) CEA Motion Inhibit.

2) to prevent Shutdown CEA withdrawal when Reg Group CEA's are NOT at the Lower Electrical Limit.

D. 1) Shutdown Group Interlock Bypass.

2) to prevent Shutdown CEA withdrawal when Reg Group CEA's are NOT at the Lower Electrical Limit.

19

PSL HLC 19 NRC EXAM Question 20 Unit 2 is 45% power steady state. A leak on the reference leg tap associated with selected "Pressurizer (pzr.) Level Controller", LT1110X occurs.

Assuming NO Operator actions what will be the response of the Pressurizer Pressure Level Control System (PPLCS)?

Indicated Pzr Level Actual Pzr Level A. decreases increases B. increases increases C. increases decreases D. decreases decreases 20

PSL HLC 19 NRC EXAM Question 21 During a Nuclear Instrument (NI) surveillance by I&C a check on detector input power supply voltage was found to be HIGH by 100 VDC.

Which ONE of the following Nls is MOST affected by this condition?

A. Unit 2 Logarithmic Startup B. Unit 1 Wide Range Log Safety C. Unit 1 Linear Power Range Safety D. Unit 2 Excore Neutron Wide Range 21

PSL HLC 19 NRC EXAM Question 22 On Unit 2 a spent fuel bundle has been dropped while being transported across the Spent Fuel Pool by the Spent Fuel Handling Machine. The status of the Fuel Handling Radiation Monitors as indicated on PC-11 are:

SA GAG-~O?

GAG-~Og GAG-011 Red Amber Amber SB GAG-O~S Red GAG-010 Amber GAG-012 Red If at the same time Unit 2 dropped their fuel assembly and had a spurious CIAS actuation and has NOT been reset, which ONE of the following correctly describes the status of the Fuel Handling Building Ventilation System?

A. It remains in its normal configuration.

B. Normal ventilation isolates but Spent Fuel Pool exhaust does NOT transfer to the Shield Building Ventilation exhaust system.

C. Normal ventilation isolates and Spent Fuel Pool exhaust transfers to BOTH trains of the Shield Building Ventilation exhaust system.

D. Normal ventilation isolates and Spent Fuel Pool exhaust transfers to ONLY one train of the Shield Building Ventilation exhaust system.

22

PSL HLC 19 NRC EXAM Question 23 A Steam Generator Tube Rupture has occurred on 1 B S/G with the following plant conditions:

  • 1 RCP in each loop is running.
  • T-avg is 475°F.
  • 1 B S/G isolation is complete.
  • 1 B S/G pressure is 840 psia.

RCS depressurization is to be performed In accordance with 1-EOP-04, "Steam Generator Tube Rupture".

The RCS pressure band should be _( 1)_ to: _{2}_.

A. 1} 790 - 890 psia; 2} meet RCP seal requirements AND to minimize RCS leakage into the S/G.

B. 1} 790 - 890 psia; 2} allow control of ruptured S/G level while minimizing dilution AND to minimize RCS leakage into the S/G.

C. 1) 840 - 890 psia;

2) meet RCP seal requirements AND to prevent lifting a secondary safety valve.

D. 1) 840 - 890 psia;

2) allow control of ruptured S/G level while minimizing dilution AND to prevent lifting a secondary safety valve.

23

PSL HLC 19 NRC EXAM Question 24 Unit 1 is performing a startup and is attempting to draw a vacuum in the Main Condenser. The Control Room has directed the NPO to place the 1 B Hogging Ejector in service.

The NPO throttles V16203 "Aux. Stm. To 1 B Hogging Ejector Isol." open to approximately 200 psig steam pressure and then opens V12576, "1B Hogging Ejector Inletfrom Cndsrs Isol".

Little to no steam flow from the Hogging ejector exhaust is observed.

Which ONE of the following is the most probable cause of little to NO steam flow from the Hogging ejector exhaust and the Operator response?

A. Steam pressure is too low.

Open V16203 to approximately 400 psig steam pressure.

B. Steam pressure is too low.

Verify proper operation of PCV-12-29 "Steam pressure control valve to SJAEs".

C. The Hogging ejector exhaust exhibits indication of Ejector stalling.

Request permission from the Control Room to place the 1A Hogging Ejector in service.

D. The Hogging ejector exhaust exhibits indication of Ejector stalling.

Close V12576, 1 B Hogging Ejector Inlet from Cndsrs Isol.

24

PSL HLC 19 NRC EXAM Question 25 Unit 1 is in Mode 1, 100% power with the following conditions:

Waste Gas Decay Tank (WGDT) 1A was recently filled << 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> ago) and is currently isolated.

Waste Gas Decay Tank 1 B is in service.

Waste Gas Decay Tank 1C has been isolated for 6 months. V6565 "Waste Gas Stop valve".has been opened and the release has just commenced.

Prior to commencing the gas release, WGDT pressures were locally verified to be:

o 1 A WGDT pressure is 155 psig o

1 B WGDT pressure is 15 psig o

1 C WGDT pressure is 150 psig 15 minutes after the release is started the following is noted by the crew:

Annunciator N-38, WASTE GAS DISCH RAD HIGH alarms.

Channel 42 (Waste Gas Radiation Monitor) blue FAIL light is energized.

The SNPO reports WGDT pressures are as follows:

o 1 A WGDT pressure is 115 psig and stable o

1 B WGDT pressure is 20 psig and very slowly rising o

1 C WGDT pressure is 120 psig and stable

1) Which ONE of the following is the cause of annunciator N-38?
2) the status of the Waste Gas Radiation Monitor is:

A. 1) WGDT 1A is cross connected to WGDT 1C.

2) failed and V6565 is open.

B. 1) WGDT 1 C is cross connected to WGDT 1 B.

2). functioning as expected and V6565 is closed C. 1) WGDT 1 C is cross connected to WGDT 1 B.

2) failed and V6565 is open..

D. 1) WGDT 1A is cross connected to WGDT 1C 2). functioning as expected and V6565 is closed 25

PSL HLC 19 NRC EXAM Question 26 Which ONE of the following will Automatically actuate the Unit 1 Containment Evacuation alarm?

A. Channel A High Range Rad Monitor in Alert B. Channel B CIS Rad monitor in Pre-Trip C. Channel A High Range Rad Monitor in High Alarm D. Channel B CIS Rad monitor in Trip 26

PSL HLC 19 NRC EXAM Question 27 Given the following:

Unit 1 has entered 1-EOP-15, "Functional Recovery Procedure".

The RO has been directed by the Unit Supervisor to establish Hot and Cold Leg Injection per 1-EOP-99 "Appendix 0", "Simultaneous Hot and Cold Leg Injection" using the most preferred method.

The most preferred method will be to align:

A. Either 1A or 1 B HPSI Pump directly to the Hot Legs.

B. Either 1 A or 1 B LPSI Pump through the Hot Leg Injection.

C. 1 A HPSI pump thru the Pressurizer Auxiliary Spray line to the Hot Legs.

D. 1A Containment Spray Pump through the Pressurizer Auxiliary Spray line to the Hot Legs.

27

PSL HLC 19 NRC EXAM Question 28 Which ONE of the following describes the RCP Motor Cooling air flow path and what affect will loss of CCW to the motor coolers have?

1 ) Air flows:

2) A Loss of CCW to the RCP Motor will result in:

A. 1) into motor via louvers and shaft rotor blowers, passed thru two air coolers, and then exhausted to Containment.

2) Containment air heating up prior to the RCP motor.

B. 1) into motor via louvers and shaft rotor blowers, passed thru two air coolers, and then exhausted to Containment.

2) the RCP motor heating up prior to the Containment.

C. 1) thru two air coolers via louvers and shaft rotor blowers, into the motor, and then exhausted to Containment.

2) the RCP motor heating up prior to the Containment.

D. 1) thru two air coolers via louvers and shaft rotor blowers, into the motor, and then exhausted to Containment.

2) Containment air heating up prior to the RCP motor.

28

PSL HLC 19 NRC EXAM Question 29 In accordance with 1-NOP-01.02, "RCP Operation", which ONE of the following states the use of RCP Seal Injection?

Seal Injection should __ (1) __ in service to an uncoupled pump __ (2) __.

A 1) NOT be placed;

2) because seal damage may occur.

B. 1) NOT be placed;

2) due to potential leakage from the seal surfaces not mating.

C. 1) be placed;

2) to keep contaminants on the surface of the Reactor Vessel water from entering the seals.

D. 1) be placed;

2) to lubricate the seal surfaces as the pump is rotated for aligning and coupling.

29

PSL HLC 19 NRC EXAM Question 30 Given the following:

  • BOTH LCV-2210 P and Q are in service and in MANUAL.
  • BOTH PCV-2201 P and Q are in service and in AUTO.
  • A system malfunction has caused ReS pressure to RISE.

Which ONE of the following describes the system malfunction?

A. Letdown pressure transmitter PT-2201 failed HIGH B. Selected Pressurizer pressure transmitter PT-11 OOX failed HIGH C. Letdown pressure transmitter PT-2201 failed LOW D. Selected Pressurizer pressure transmitter PT-11 OOX failed LOW 30

PSL HLC 19 NRC EXAM Question 31 Unit 1 is at 100% power when the following alarm is received:

Regenerative Heat Exchanger Outlet Temp High M-28 If the temperature continues to rise which ONE of the following AUTOMATIC system responses would you expect to see and what are the required Operator actions?

A. "Letdown isolation valve" V2516 closed. Start additional Charging pumps to clear alarm then re-establish letdown flow.

B. "Letdown isolation valve" V2515 closed. Start additional Charging pumps to clear alarm then re-establish letdown flow.

C. "Letdown isolation valve" V2516 closed. Stop ALL running Charging Pumps.

D. "Letdown isolation valve" V2515 closed. Stop ALL running Charging Pumps.

31

PSL HLC 19 NRC EXAM Question 32 The valve stroke test of Loop "2A SDC Suction Valve", V3480 has been conducted per OP 0010125A, "Surveillance Data Sheets", with the following results:

Open 40.1 sec Closed 42.3 sec Below are the Data Sheet 10 Criteria.

2A Stroke Dir.

Min Allowed Max Allowed Limit Time V3480 Shutdown Open 31.0 41.9 45.5 Cooling Suction Closed 29.8 40.2 43.8 Which ONE of the following states the required action, if any, and the status of the valve?

A. The stroke times are less than the Limit Time, NO action required.

B. Declare the valve inoperable and initiate a 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> Condition Report.

C. Retest the valve. If the retest meets the allowable time NO further action required.

D. Retest the valve or declare the valve inoperable. If retested and outside the allowable time, initiate a Condition Report and analyze the data verifying that the new stroke time is acceptable within 96 hours0.00111 days <br />0.0267 hours <br />1.587302e-4 weeks <br />3.6528e-5 months <br />.

32

PSL HLC 19 NRC EXAM Question 33 Unit 2 is operating at 100% power when the feeder breaker to MCC-2B5 (2-40520) trips open.

How many HPSI and LPSI Cold Leg Safety Injection valves have been deenergized?

HPSI Valves A. 1 B. 1 C.2 D.2 LPSI Valves 1

2 1

2 33

PSL HLC 19 NRC EXAM Question 34 Unit 1 is at 100% power. "Pressurizer Safety valve" V1200 discharge temperature has increased from 150°F to 220°F over the last 10 minutes.

Which ONE of the following could have caused this temperature increase?

A. Placing the Pressurizer on Recirc.

B. Removing the Pressurizer from Recirc.

C. Lowering the Quench Tank pressure from 3 psig to 0.5 psig.

D. Raising the Quench Tank pressure from 3 psig to 6 psig.

34

PSL HLC 19 NRC EXAM Question 35 Unit 2 is in Mode 4 cooling down for a refueling outage. As the Unit transitions from Mode 4 to Mode 6, which ONE of the following states the required CCW equipment OPERABLE /

AVAILABLE during this transition?

(Assume Mode 6, refueling cavity level is 19 feet above the Reactor Vessel Flange and Mode 6 equipment status requirements in accordance with 0010145, "Shutdown Cooling Controls".)

Mode 4 Mode 6 A. Two independent CCW Two CCW pumps OPERABLE loops OPERABLE Two CCW HX's AVAILABLE B. Two independent CCW Two CCW pumps AVAILABLE Loops OPERABLE One CCW HX AVAILABLE C. One CCW pump and HX OPERABLE One CCW pump OPERABLE and one CCW pump and HX One CCW HX OPERABLE AVAILABLE D. One CCW pump and One CCW HX One CCW pump AVAILABLE Operable One CCW HX AVAILABLE 35

PSL HLC 19 NRC EXAM Question 36 Unit 2 is operating at 100% power with the following:

2A and 2B CCW pumps running.

ALL AB buses are aligned to the B side.

The 2C CCW pump is aligned and started to replace the 2B CCW pump. The 2B CCW pump is stopped in preparation to remove it from service for PM. The 2B CCW pump is yet to be placed in 'Pull to Lock' when the following occurs:

At time 0220 a Loss Of Offsite Power (LOOP) occurs and BOTH Diesel Generators start and load.

At time 0225 a LOCA with subsequent SIAS occurs.

Which ONE of the following identifies the status of the CCW pumps?

At time 0221 :

At time 0226:

A. ALL three CCW pumps are running.

ALL three CCW pumps are running.

B. ALL three CCW pumps are running.

2A and 2C CCW pumps are running C. 2A and 2C CCW pumps are running.

ALL three CCW pumps are running.

D. 2A and 2C CCW pumps are running.

2A and 2C CCW pumps are running.

36

PSL HLC 19 NRC EXAM Question 37 Unit 2 is operating at 90% power with the following conditions:

H-17 PZR CHANNEL X LEVEL HIGH/LOW, is in alarm.

H-9 PZR CHANNEL X PRESS HIGH/LOW, is in alarm.

Pressurizer (PZR) level is slowly rising.

Letdown flow is dropping slowly.

ALL PZR heaters are ON.

BOTH Spray Valves indications are RED and GREEN.

Which ONE of the following would cause the observed conditions?

(assuming NO OPERATOR actions)

A. LCV-2110P, "Level Control Valve" is drifting CLOSED.

B. PCV-2201 P, "Pressure Control Valve" is drifting OPEN.

C. The controlling PZR level channel has failed LOW.

D. The controlling PZR level channel has failed HIGH.

37

PSL HLC 19 NRC EXAM Question 38 Unit 1 is at 100% power with the following:

Pressurizer Pressure control channel X is selected for control.

HIC-1100, "Pressurizer Spray Valve Controller" indicates '0' (minimum) controller output.

Based on these plant conditions:

1) PT-1100X has failed:
2) assuming NO OPERATOR action, the plant will:

A. 1) LOW.

2) trip on TMLP.

B. 1) LOW.

2) trip on High Pressurizer pressure.

C. 1) HIGH.

2) trip on TMLP.

D. 1) HIGH.

2) trip on High Pressurizer pressure.

38

PSL HLC 19 NRC EXAM Question 39 Unit 1 is in Mode 1. A loss of the MA 120 VAC Instrument Bus occurs.

Which ONE of the following identifies the response of the Reactor Protective System as a result of the loss of the Instrument Bus?

A. Two (2) Trip Circuit Breakers open due to a loss of power to one (1) "K" Relay.

B. Two (2) Trip Circuit Breakers open due to a loss of power to two (2) "K" Relays.

C. Four (4) Trip Circuit Breakers open due to a loss of power to one (1) "K" Relay.

D. Four (4) Trip Circuit Breakers open due to a loss of power to two (2) "K" Relays.

39

PSL HLC 19 NRC EXAM Question 40 Unit 2 is performing a cooldown per 2-GOP-305, "Reactor Plant Cooldown - Hot Standby To Cold Shutdown", for a refueling outage with the following conditions:

Time: 11:30 RCS pressure is 1750 psia.

RCS temperature is 504°F.

2A & 2B S/Gs are 720 psia.

Time: 11 :31 2A Steam Line ruptures outside Containment and just upstream of the MSIV.

RCS pressure is 1640 psia and rapidly lowering.

S/G pressures are 580 psia and rapidly lowering.

1) What automatic ESFAS actuation(s) are expected?
2) Which procedure will be implemented to mitigate the event?

A. 1) BOTH MSIS, and SIAS

2) 2-EOP-05, Excess Steam Demand B. 1) ONLY MSIS
2) 2-EOP-05, Excess Steam Demand C. 1) BOTH MSIS, and SIAS
2) 2-0NP-01.01 Plant Condition 1 Steam Generator Heat Removal L TOP Not in Effect 0.1) ONLY MSIS
2) 2-0NP-01.01 Plant Condition 1 Steam Generator Heat Removal L TOP Not in Effect) 40

PSL HLC 19 NRC EXAM Question 41 Unit 2 is at full power when the following conditions occur:

Normal Charging flow was lost due to a rupture in Containment downstream of V2429, "Charging Pump Disch" at Penetration #27 Isolation.

The alternate Charging flowpath to the RCS through the HPSI header is being aligned.

Which ONE of the following Limiting Conditions for Operation (LCO) will require the FIRST Technical Specification action during this alignment and why?

A.

LCO 3.0.3, Limiting Conditions for Operation, due to ALL Charging pumps placed in STOP.

B.

LCO 3.5 2, Emergency Core Cooling Systems, due to the A HPSI header being inoperable.

C.

LCO 3.1.2.2, Reactivity Control Systems, due to loss of a Boron injection flowpath.

D.

LCO 3.4.3, Pressurizer, due to the reduction in Pressurizer level from RCP Controlled Bleed-Off flow with NO charging flow.

41

PSL HLC 19 NRC EXAM Question 42 Unit 1 is at 100% power when a rupture in the 1A CCW header occurs. The crew has entered 1-0310030, "Component Cooling Water Off Normal Operation".

As a result of the actions carried out in the above procedure,

1) how has Containment Cooling been compromised?
2) what actions must be taken within 45 minutes if Containment temperature can not be reduced to less than or equal t0120°F?

A.

1) Partial loss of CCW flow to the A and B Containment Coolers.
2) Initiate a Reactor trip and carry out EOP-01, "Standard Post Trip Actions".

B.

1) Partial loss of CCW flow to the A and B Containment Coolers.
2) Perform a down power lAW 2-0NP-22.01, "Rapid Down Power".

C.

1) Total loss of CCW flow to the A and B Containment Coolers.
2) Initiate a Reactor trip and carry out EOP-01, "Standard Post Trip Actions".

D.

1) Total loss of CCW flow to the A and B Containment Coolers.
2) Perform a down power lAW 2-0NP-22.01, "Rapid Down Power".

42

PSL HLC 19 NRC EXAM Question 43 Unit 1 is in 1-EOP-15, "Functional Recovery".

As Containment pressure increases which ONE of the following states the MINIMUM Containment Cooling equipment that will meet the Containment Temperature and Pressure Control safety function for the specific Containment Pressure / Temp?

Containment pressure I Temp.

A.

B.

C.

D.

43 Containment cooling equip.

One Cont. Cooling Fan Two Cont. Cooling Fans 1 A CS pp with 2800 gpm flow AND ONE Cont. Cooling Fan 1 A CS pp with 2800 gpm flow AND TWO Cont. Cooling Fans

PSL HLC 19 NRC EXAM Question 44 Which ONE of the following is performed during EOP-01, "Standard Post Trip Actions" on Unit 2 but NOT on Unit 1 for a Reactor trip from 100% power?

(assume uncomplicated Reactor trip)

A. Closing the Spillover Bypass valve MV-08-814.

B. Placing the ADV's in AUTOMATIC.

C. Closing the MSR block valves.

D. Depressing the 15% Main Feedwater bypass valves reset pushbutton.

44

PSL HLC 19 NRC EXAM Question 45 Unit 1 has implemented 1-EOP-15, "Functional Recovery" due to a total loss offeedwater. Once Through Cooling (OTC) has been established 15 minutes ago. The 1A Auxiliary Feedwater pump is now available as a feedwater source. BOTH Steam Generator levels indicate '0' Wide Range level.

Which ONE of the following indicates the Auxiliary Feedwater flow rate that should be initiated to the Steam Generator( s) and the bases for the flow?

A.

Feed BOTH Steam Generators with flow as low as possible for the first 5 minutes due to water hammer and thermal shock concerns of the feed ring.

B.

Feed ONE Steam Generator with flow less than 150 gpm for the first 5 minutes due to water hammer and thermal shock concerns of the feed ring.

C.

Feed BOTH Steam Generators with flow as low as possible for the first 5 minutes due to thermal shock concerns of the Steam Generator tubes.

D.

Feed ONE Steam Generator with flow less than 150 gpm for the first 5 minutes due to thermal shock concerns of the Steam Generator tubes.

45

PSL HLC 19 NRC EXAM Question 46 Unit 2 is at 48% power steady state conditions with the following:

2A and 2B Condensate pumps are running.

2A Main Feedwater pump is running.

Which ONE of the following will result in the automatic trip of the 2A Main Feedwater pump?

A. Main Feedwater suction pressure indicates 270 psig.

B. MSIS occurs.

C. 2A Main Feedwater pump suction valve indication changes from OPEN to CLOSED. (indication only)

D. Main Feedwater pump lube oil pressure indicates 5 psig.

46

PSL HLC 19 NRC EXAM Question 47 Given the following:

Unit 2 has evacuated the Control Room due to a fire and has implemented 2-0NP-100.02, "Control Room Inaccessibility".

The Unit was tripped four (4) hours ago and is currently in Hot Standby (532°F).

Condensate Storage Tank (CST) level is 40 feet.

Steam Generator levels are being maintained constant at 63% Narrow Range using 2A and 2B Auxiliary Feedwater pumps (AFW).

Steam Generator pressures are 900 psi a using the ADV's.

It is desired to be on SDC entry conditions in 16 hours1.851852e-4 days <br />0.00444 hours <br />2.645503e-5 weeks <br />6.088e-6 months <br />.

Which ONE of the following is the approximate Auxiliary Feedwater flow rate (Per Steam Generator) that will accomplish this?

(assume linear AFW flow rate through the cooldown)

A. 75 gpm B. 90 gpm C. 104 gpm D. 120 gpm 47

PSL HLC 19 NRC EXAM Question 48 The following annunciator is received on RTGB 101 with Unit 1 at 100% power:

4 KV SWGR 1A3

~ CURRENT TRIP B-14 Which ONE of the following indicates the:

1) Status of the 1 A3 4.16 KVAC bus?
2) Procedure that would be implemented?

A. 1) The bus is energized from the Diesel Generator.

2) 1-0NP-47.01, "Loss of A Safety Related A.C. Bus" B. 1) The bus is de-energized but the 1A Diesel Generator is running.
2) 1-0NP-47.01, "Loss of A Safety Related A.C. Bus" C. 1) The bus is energized from the Diesel Generator.
2) 1-EOP-01. "Standard Post Trip Actions" D. 1) The bus is de-energized but the 1A Diesel Generator is running.
2) 1-EOP-01, "Standard Post Trip Actions" 48

PSL HLC 19 NRC EXAM Question 49 Unit 2 was at 100% power when a loss of the 2A DC bus occurs.

Which ONE of the following indicates:

1) the Auxiliary Feedwater flow control available from the Control Room?
2) the 2C AFW pump steam and feed alignment?

(assume AB DC bus aligned to the A side)

The 2B AFW pump and header flow control valves to the:

A. 1) 2A Steam Generator.

2) Steam from the 2B Steam Generator to the 2C AFW pump feeding the 2A Steam Generator.

B. 1) 2A Steam Generator.

2) Steam from the 2A Steam Generator to the 2C AFW pump feeding the 2B Steam Generator.

C. 1) 2B Steam Generator.

2) Steam from the 2A Steam Generator to the 2C AFW pump feeding the 2A Steam Generator.

D. 1) 2B Steam Generator.

2) Steam from the 2B Steam Generator to the 2C AFW pump feeding the 2B Steam Generator.

49

PSL HLC 19 NRC EXAM Question 50 The 1 A Emergency Diesel Generator (EDG) is running with its output breaker closed for a surveillance run. 45 minutes into the run the EDG trips on high jacket water temperature.

It has been 30 minutes since the 1A EDG trip and nothing has been reset on the EDG. Jacket water temperature indicates 190°F. Five minutes later a Loss of Offsite power occurs. The Unit Supervisor directs the SNPO to reset the 1 A EDG lockout relay.

Which ONE of the following identifies the 1 A EDG initial response to the lockout relay reset and what other conditions for running / starting the 1 A EDG are applicable?

The 1A EDG will:

A. start and load on the bus, but will trip if the high jacket water temperature comes back in.

B. start and load on the bus and continue to run regardless of the jacket water temperature.

C. NOT start until the jacket water temperature lowers to 180°F.

D. NOT start until the shutdown relay is also reset.

50

PSL HLC 19 NRC EXAM Question 51 Which ONE of the following Unit 1 process monitors, that if failed to perform its control function, could result in an UNMONITORED radioactive effluent release.

A. Letdown Process Monitor B. Component Cooling Water Monitor C. Steam Generator Blowdown Monitor D. Condenser Air Ejector Monitor 51

PSL HLC 19 NRC EXAM Question 52 Unit 1 is backwashing the 1 B Turbine Cooling Water heat exchanger strainer. TCW heat exchanger SB21215 "TCW heat exchanger (TCW) inlet crosstie valve" is open.

With SB21215 open, which ONE of the following identifies the operability status of the Intake Cooling water trains and the explanation WHY they are Operable or Inoperable?

A. BOTH ICW trains are NOT operable due to lack of train separation.

B. ONLY the 1 B ICW train is NOT operable. Minimum 'B' side heat exchanger flow requirements will NOT be met due to increased flow required to backwash the strainer.

C. BOTH ICW trains are operable. MV-21-2 and MV-21-3, A and B ICW train to TCW Hxs.

close on SIAS.

D. BOTH ICW trains are operable. The Operator performing the backwash is instructed to close SB21215 during accident conditions.

52

PSL HLC 19 NRC EXAM Question 53 Unit 1 is at 100% power with the 1 C Instrument Air compressor in RUN and the 1 D Instrument air compressor is in AUTO.

The 1 C Instrument air compressor tripped on low oil pressure.

Instrument air pressure has now lowered to 105 psig.

Which ONE of the following identifies the status of the 1 D Instrument air compressor?

A. RUNNING. The compressor AUTO started when the 1 C compressor tripped.

B. RUNNING. The compressor AUTO started at 105 psig.

C. NOT running. The compressor will AUTO start at 95 psig.

D. NOT running. The compressor MUST be manually RESET and manually started.

53

PSL HLC 19 NRC EXAM Question 54 Unit 1 and Unit 2 are at full power when an Instrument Air leak occurs on Unit 1.

Instrument Air pressure on Unit 1 is 84 psig.

Instrument Air pressure on Unit 2 is 95 psig.

Which ONE of the following identifies the status of the Instrument Air crosstie valves?

(lIp!f i)

((/pr(" 2.)

PCV-18-6}lnst Air Cross-Tie From I To Unit 1 A. open B. open C. closed D. closed 54 PCV-18-~nst Air Cross-Tie From I To Unit 1 open closed closed open

PSL HLC 19 NRC EXAM Question 55 Which ONE of the following would result in a VIOLATION of Containment Integrity while the Unit is in Mode 1?

A. The Containment Air Lock inner door is inoperable and the outer door is opened to investigate the inoperable inner door.

B. A Containment Isolation valve stroke time is in the Alert range.

C. A motor operated Containment Isolation valve will NOT fully close with the motor but is closed manually and is de-energized.

D. Opening a locked manual Containment Isolation valve in the penetration room and stationing an operator in the Control Room to close this valve in the event of an accident.

55

PSL HLC 19 NRC EXAM Question 56 During a Unit 1 Reactor startup, power has been stable for one hour at 15%.

CEAs are at 110" on group 7.

The Turbine is on line.

The CEDS control is placed in Manual Individual mode to withdraw one CEA in group 7 that is 4" below the other CEA's in the group.

When the RCO initially withdraws the CEA, the CEA control switch CAN NOT be taken out of the WITHDRAW position.

As a result which ONE of the following will occur? (Assume NO Operator action)

A. T -ave and T -ref will increase as power rises; the CEA withdrawal will stop when steam bypass demand begins.

B. T-ave and T-ref will increase as power rises; the CEA withdrawal will stop when any of the cold leg temperatures exceed 549°F.

C. T-ave will increase as power rises; T-ref will remain approximately the same; the CEA withdrawal will stop when T-ave is 6.6°F greater than T-ref.

D. T-ave will increase as power rises; T-ref will remain approximately the same; the CEA withdrawal will stop when a group deviation occurs.

56

PSL HLC 19 NRC EXAM Question 57 Unit 1 is cooling down for a refueling outage with the following conditions:

RCS Cold Leg temperature is 300°F.

RCS pressure is 430 psia.

BOTH PORV's are selected to Low Range.

A transient occurs and RCS pressure rises to 515 psia with the following in alarm:

PZR RELIEF VALVE ANTICIPATORY ALARM H-21 Which ONE ofthe following states the status of the PORV's?

The PORV's are:

A. NOT open but will open if RCS pressure rises to 2: 530 psia.

B. NOT open but will open if RCS Cold Leg temperature lowers to :5 240°F.

C. OPEN and will NOT automatically close until RCS pressure lowers to :5 510 psia.

D. OPEN and will NOT automatically close until RCS Cold Leg temperature rises to 2:

30rF.

57

PSL HLC 19 NRC EXAM Question 58 The following indications are observed on Unit 1 :

Process S/G 1 A Channel A S/G Level 65%

S/G Press FAILED LOW FW Hdr. Press 1050 psia S/G 1A Channel B 65%

880 psia 1048 psia S/G 1 B Channel A 65%

880 psia FAILED LOW S/G 1 B Channel B FAILED LOW 880 psi a 1045 psia If the above failed channels are NOT bypassed which ONE of the following failures would result in an AFAS LOCKOUT?

A. S/G 1 B Channel A S/G Level failed LOW.

B. S/G 1A Channel B FW Hdr Pressure failed LOW.

C. S/G 1 B Channel A S/G pressure failed LOW.

D. S/G 1 B Channel B FW Hdr Pressure failed LOW.

58

PSL HLC 19 NRC EXAM Question 59 The following indications are observed on Unit 1 QSPDS Channel A and Channel B:

CET Channel A

????

ChannelB

?598°F Which ONE of the following indicates the status of the above CET's and the potential use of the CET's for further QSPDS calculations?

A. Channel A is considered OUT OF RANGE Channels B is considered SUSPECT. BOTH channels are NOT used for further calculations.

B. Channel A is considered OUT OF RANGE Channel B is considered SUSPECT. Channel A is NOT USED for further calculations Channel B IS used for further calculations.

C. BOTH Channels ARE considered OUT OF RANGE. BOTH channels are NOT used for further calculations.

D. BOTH Channels ARE considered OUT OF RANGE. Channel A IS NOT used for further calculations, Channel B IS used for further calculations.

59

PSL HLC 19 NRC EXAM Question 60 Unit 1 is experiencing a LOCA and a Loss of Offsite power. ALL safeguards actuated ventilation systems are in service.

Which ONE of the following systems is in service to LIMIT THE RELEASE of Iodine from the Containment and what design feature is installed to improve Iodine removal efficiency?

A. Shield Building fans HVE-6A and HVE-6B with charcoal filter trains.

Demisters to remove water particles and heaters to reduce humidity.

B. Shield Building fans HVE-6A and HVE-6B with charcoal filter trains.

Demisters to removewater particles and heaters to increase the temperature of the discharged air.

C. Airborne Radiation Removal units HVE-1 and HVE-2 with charcoal filter trains.

Demisters to remove water particles.

D. Airborne Radiation Removal units HVE-1 and HVE-2 with HEPA filters to remove particulate and Iodine.

Heaters to control humidity.

60

PSL HLC 19 NRC EXAM Question 61 Unit 1 has implemented 1-EOP-03, "Loss of Coolant". A Loss Of Offsite Power (LOOP) has also occurred on the Reactor trip. BOTH Emergency Diesel Generators have started and loaded on their respective bus, however the feeder breaker to the MCC 1A5 tripped open.

Which ONE of the following states ALL available Containment Hydrogen removal systems?

A. 1 A and 1 B Hydrogen Recombiners. HVE-7 A and HVE-7B Hydrogen Purge fans.

B. 1A and 1B Hydrogen Recombiners. HVE-7B Hydrogen Purge fan.

C. 1 B Hydrogen Recombiner. HVE-7B Hydrogen Purge fan.

D. 1B Hydrogen Recombiner. HVE-7A and HVE-7B Hydrogen Purge fans.

61

PSL HLC 19 NRC EXAM Question 62 Unit 1 is in Mode 6. Given the following events and conditions:

"A" train Containment Purge system is in service with suction aligned to the Refueling Cavity The Upper Guide Structure is being lifted A CIAS monitor reads 95 mR/Hr B CIAS monitor reads 102 mR/Hr C CIAS monitor reads 85 mR/Hr D CIAS monitor reads 87 mR/Hr

../

II it-a / A-f ~

t.P.a/ / ro.d'-.r ~

G

~;P

~./l-oL e:-

Which ONE of the following statements correctly describes the response of the Containment Purge system?

A. Containment purge is automatically secured.

B. Containment purge remains in its current configuration.

C. The Containment purge suction is automatically aligned to the Containment Ring Header.

D. The Containment purge discharge is automatically aligned to the Shield Building Exhaust system.

62

PSL HLC 19 NRC EXAM Question 63 Unit 1 has experienced an uncomplicated Reactor / Turbine trip. 1-EOP-01, "Standard Post Trip Actions" are complete. The unit is being maintained in Hot Standby conditions using the Steam Dump Control System (SBCS). SBCS controller HIC-8801 is in MANUAL controlling RCS temperature at 532°F. The remainder of the SBCS is in AUTOMATIC. HIC-8801 malfunctions and PCV-8801 goes full OPEN.

Assuming NO operator actions, approximately what RCS temperature will be reached before the cooldown is terminated?

B. 504°F D. 52rF 63

PSL HLC 19 NRC EXAM Question 64 BOTH units are at 100% power. A tornado has touched down east of A 1 A near the intake canal.

The intake canal has sustained damage and is full of debris.

The following alarms have been received:

Unit 1 Unit 2 INTAKE WATER LEVEL LOW INTAKE WATER LEVEL LOW E-17 M-21 Local Intake level is -9.5 foot elevation.

Discharge Canal Level is 10 foot elevation.

INTAKE WATER LEVEL LOW INTAKE WATER LEVEL LOW LA-1 LB-1 The Unit has entered 1 (2)-0360030, "Operational Requirements For The Emergency Cooling Water Canal". The SRO has decided to perform a Unit Shutdown. What are the order of expected actions he is going to direct the Operators to perform?

Perform a Unit shutdown and:

A. open the SE-37-1 and SE-37-2, "UHS Barrier valves". Throttle circulating water pump discharge valves at first sign of pump cavitation.

B. open the SE-37-1 and SE-37-2, "UHS Barrier valves". Stop the circulating water pumps as the down power progresses.

C. stop the circulating water pumps as the downpower progresses. Open SE-37-1 and SE-37-2, "UHS Barrier valves" when the unit is shut down.

D. throttle Circulating water pump discharge valves at first sign of pump cavitation. Open SE-37-1 and SE-37-2, "UHS Barrier valves" when the unit is shut down.

64

PSL HLC 19 NRC EXAM Question 65 Unit 1 and Unit 2 have evacuated the Control Rooms due to fires in the cable spreading rooms.

Offsite power is available.

1 (2)-ONP-1 00.02, "Control Room Inaccessibility" is being implemented.

1) lAW 1 (2)-ONP-1 00.02, which ONE of the following indicates the Appendix R protected trains?
2) Which ONE of the following indicates the reason one Emergency Diesel Generator overspeed trip levers on each unit are placed in trip?

A. 1) Unit 1 A train components are protected. Unit 2 B train components are protected.

2) To prevent a start when the protective trips are disabled due to the Normal/Isolate switches placed in ISOLATE.

B. 1) Unit 1 B train components area protected. Unit 2 A train components are protected.

2) To prevent an inadvertent start from a fire induced short circuit.

C. 1) Both Unit's A train is protected.

2) To prevent an inadvertent start from a fire induced short circuit.

D. 1) Both Units B train is protected.

2) To prevent a start when the protective trips are disabled due to the Normal/Isolate switches placed in ISOLATE.

65

PSL HLC 19 NRC EXAM Question 66 Unit 1 is performing a downpower due to a small Steam Generator tube leak.

A loss of the DEH computer has occurred.

Which ONE of the following indicates the status of the DEH control system and how the down power will be performed due to the loss of the DEH computer?

DEH control system will be in:

A. Turbine Manual. Governor Valves (GV) will be manually controlled by GV lower pushbutton operating in SINGLE valve mode.

B. Turbine Manual. Governor Valves (GV) will be manually controlled by GV lower pushbutton operating in SEQUENTIAL valve mode.

C. Operator Auto, however, the Governor Valves (GV) will be manually controlled by GV lower pushbutton operating in SINGLE valve mode.

D. Operator Auto, however, the Governor Valves (GV) will be manually controlled by GV lower pushbutton operating in SEQUENTIAL mode.

66

PSL HLC 19 NRC EXAM Question 67 Unit 1 has entered 1-0610030, "Secondary Chemistry - Off Normal" An Action level 3 Steam Generator parameter has been exceeded.

Which parameter has been exceeded and what action is the plant required to take?

A. Condensate Dissolved Oxygen.

Shutdown to Mode 3 as quickly as safe plant operation permits.

B. Condensate Dissolved Oxygen.

Bring the parameter to below Action level 3 within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> or perform a shutdown to Mode 3 as quickly as safe plant operation permits.

C. Cation Conductivity.

Shutdown to Mode 3 as quickly as safe plant operation permits.

D. Cation Conductivity.

Bring the parameter to below Action level 3 within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> or perform a shutdown to Mode 3 as quickly as safe plant operation permits.

67

PSL HLC 19 NRC EXAM Question 68 You are an Active Licensed Reactor Operator and have just completed your Biennial physical exam. The Medical Review Officer (MRO) has informed you; you have high blood pressure and must start medication to control this condition.

Which ONE of the following states your ability to stand watch in a Tech Spec position?

You can:

A. NOT stand watch, however as soon as you start taking blood pressure medication, you will be considered active and can stand shift. Your license will now have a restriction to take the required medication.

B. NOT stand watch until your medication is started and the Medical review officer re-examines you and determines your blood pressure is acceptable. Your license will now have a restriction to take the required medication.

C. stand watch until proven the blood pressure medication is not effective in controlling the condition. Your License will NOT have a restriction as long as the medication is controlling the condition.

D. stand watch until the NRC reviews your condition to determine if the medication can control the condition. Your License will NOT have a restriction as long as the medication is controlling the condition.

68

PSL HLC 19 NRC EXAM Question 69 Unit 1 is in a refueling outage.

Which ONE of the following states when Mode 5 is entered?

Mode 5 is entered when:

A. the FIRST stud and nut on the Head is fully tensioned.

B. the LAST stud and nut on the Head is fully tensioned.

C. the Reactor Vessel head is first placed on the Reactor Vessel flange.

D. ALL the studs and nuts have completed the FIRST pass of tensioning.

69

PSL HLC 19 NRC EXAM Question 70 Unit 1 has been in a refueling outage for 12 days. The core is being unloaded with the following in service:

1 A Wide Range Neutron Monitor 1 B Wide Range Neutron Monitor 1 A SOC Loop is in service with 3300 gpm flow rate.

1 B SOC Loop is available but NOT operating.

Which ONE of the following would require suspending core alterations in accordance with Technical Specifications?

A. 'A' Train manual initiation CIAS surveillance failed.

B. NO audible indication in the Control Room from the 1 B Wide Range Nuclear Instrumentation.

C. NO visual indication in the Control Room from the 1 A Wide Range Nuclear Instrumentation.

O. The 1 B SOC loop is removed from service due to a leaking CCW cooler line.

70

PSL HLC 19 NRC EXAM Question 71 Unit 1 is at 100% power preparing for unit shutdown for a refueling outage. The 1 A Charging pump is running and the RCO is preparing to start the 1 B Charging pump lAW 1-NOP-02.02, "Charging and Letdown".

Which ONE of the following is the correct order to start the 1 B Charging Pump?

A. 1) Start the 1 B Charging pump.

2) Contact the SNPO to ensure the 1 B Charging pump is operating properly.
3) Notify Health Physics the 1 B Charging pump is running.

B. 1) Contact the SNPO to ensure the 1 B Charging pump is ready to operate.

2) Notify Health Physics of the pending start of the 1 B Charging pump.
3) Approximately 15 minutes later, start the 1 B Charging pump.

C. 1) Notify Health Physics of the pending start of the 1 B Charging pump.

2) Start the 1 B Charging pump.
3) Contact the SNPO to ensure the 1 B Charging pump is operating properly.

D. 1) Contact the SNPO to ensure the 1 B Charging pump is ready to operate.

2) Approximately 15 minutes later, start the 1 B Charging pump.
3) Notify Health Physics the 1 B Charging pump is running.

71

PSL HLC 19 NRC EXAM Question 72 A St. Lucie non-licensed operator is being sent to perform a valve alignment in the RAB. The dose rate in the area of the job is 120 mr/hr. The operator's exposure record to date for the year is 890 mrem.

What is the MAXIMUM time the Operator can stay in this area without exceeding his FPL annual limit? (assume NO extension allowed)

A. 40 minutes B. 45 minutes C. 54 minutes D. 60 minutes 72

PSL HLC 19 NRC EXAM Question 73 Unit 1 has tripped from 100% power. 1-EOP-09, "Loss of Offsite Power / Loss of Forced Circulation" has been implemented. The 1 A EDG is NOT running and the 1 B EDG is running loaded on its respective bus.

Which ONE of the following MINIMUM conditions indicates when 1-EOP-09 can be exited?

(assume all Safety Functions are being met in 1-EOP-09)

A. The 1 A EDG has been started and is loaded on its respective bus.

A cool down to Shutdown Cooling conditions is desired.

B. The 1 A EDG has been started and is loaded on its respective bus.

Maintaining Mode 3 conditions is desired.

C. Both 1A3 4.16 KV AND 1B3 4.16 KV buses have been restored from the Unit 1 Startup Transformers.

A cool down to Shutdown Cooling conditions is desired.

D. The 1 A3 4.16 KV OR 1 B3 4.16 KV buses have been restored from a Unit 1 Startup Transformer.

Maintaining Mode 3 conditions is desired.

73

PSL HLC 19 NRC EXAM Question 74 Unit 1 Unit Supervisor is directing implementation of 1-EOP-15, "Functional Recovery". Direction to the RO is to perform Safety Function status checks.

Which ONE of the following identifies the instrumentation that is to be selected FIRST to assess the status of Safety Functions?

A. ERDADS instrumentation B. DCS instrumentation C. Instrumentation ALSO designated as Remote Shutdown instrumentation.

D. Instrumentation identified by White Bezel around the face of the instrument.

74

PSL HLC 19 NRC EXAM Question 75 Unit 1 has completed 1-EOP-01, "Standard Post Trip Actions" The Unit supervisor has completed the diagnostic flow chart and has implemented an optimal EOP. Shortly after entering this optimal EOP he gives direction to cooldown the RCS to THOT less than 510°F.

Which ONE of the following optimal EOP's has the crew entered?

A. 1-EOP-03, "Loss of Coolant Accident" B. 1-EOP-04, "Steam Generator Tube Rupture" C. 1-EOP-05, "Excess Steam Demand" D. 1-EOP-06, "Total Loss of Feedwater" 75

St. Lucie HLC-19 NRC RO I SRO December 2009 Written Exam References

1. Generator Capability Curve
2. Steam Tables
3. 1-EOP-99, Figures 1A &1 B RCS Pressure Temperature
4. 1-EOP-99, Figure 2, Safety Injection Flow VS. RCS Pressure
5. Figure 3 and 4, 2-0NP-100.02 Control Room Inaccessibility

ANSWER KEY REPORT for 2009 RO Test Test Form: 0 Answers ID

. P()ints Type 0

ANSWER KEY 1 1.00 MCS A

2 ANSWER KEY 2 1.00 MCS B

3 ANSWER KEY 3 1.00 MCS C

4 ANSWER KEY 4 1.00 MCS C

5 ANSWER KEY 5 1.00 MCS C

6 ANSWER KEY 6 1.00 MCS A

7 ANSWER KEY 7 1.00 MCS C

8 ANSWER KEY 8 1.00 MCS A

9 ANSWER KEY 9 1.00 MCS B

10 ANSWER KEY 10 1.00 MCS A

11 ANSWER KEY 11 1.00 MCS C

12 ANSWER KEY 12 1.00 MCS D

13 ANSWER KEY 13 1.00 MCS C

14 ANSWER KEY 14 1.00 MCS A

15 ANSWER KEY 15 1.00 MCS D

16 ANSWER KEY 16 1.00 MCS B

17 ANSWER KEY 17 1.00 MCS B

18 ANSWER KEY 18 1.00 MCS D

19 ANSWER KEY 19 1.00 MCS A

20 ANSWER KEY 20 1.00 MCS C

21 ANSWER KEY 21 1.00 MCS A

22 ANSWER KEY 22 1.00 MCS B

23 ANSWER KEY 23 1.00 MCM B (1.00) D (l.00) 24 ANSWER KEY 24 1.00 MCS D

25 ANSWER KEY 25 l.00 MCS D

26 ANSWER KEY 26 l.00 MCS D

27 ANSWER KEY 27 1.00 MCS B

28 ANSWER KEY 28 1.00 MCS A

29 ANSWER KEY 29 1.00 MCS A

30 ANSWER KEY 30 1.00 MCS C

31 ANSWER KEY 31 1.00 MCS D

32 ANSWER KEY 32 l.00 MCS D

33 ANSWER KEY 33 l.00 MCS C

34 ANSWER KEY 34 l.00 MCS C

35 ANSWER KEY 35 l.00 MCS B

36 ANSWER KEY 36 l.00 MCS C

37 ANSWER KEY 37 1.00 MCS A

38 ANSWER KEY 38 l.00 MCS B

39 ANSWER KEY 39 l.00 MCS D

40 ANSWER KEY 40 l.00 MCS D

41 ANSWER KEY 41 l.00 MCS A

42 ANSWER KEY 42 l.00 MCM C (l.00) D (l.00) 43 ANSWER KEY 43 l.00 MCS D

44 ANSWER KEY 44 l.00 MCS C

45 ANSWER KEY 45 l.00 MCS B

46 ANSWER KEY 46 l.00 MCS A

Tuesday, February 09,201010:08:35 AM 1

ANSWER KEY REPORT for 2009 RO Test Test Form: 0 Answers ID Points Type 0

47 ANSWER KEY 47 l.00 MCS C

48 ANSWER KEY 48 l.00 MCS B

49 ANSWER KEY 49 l.00 MCS C

50 ANSWER KEY 50 l.00 MCS B

51 ANSWER KEY 51 l.00 MCM B (l.00) C (l.00) 52 ANSWER KEY 52 l.00 MCS C

53 ANSWER KEY 53 l.00 MCS B

54 ANSWER KEY 54 l.00 MCS D

55 ANSWER KEY 55 l.00 MCS D

56 ANSWER KEY 56 l.00 MCS D

57 ANSWER KEY 57 l.00 MCS A

58 ANSWER KEY 58 l.00 MCS D

59 ANSWER KEY 59 l.00 MCS A

60 ANSWER KEY 60 l.00 MCS A

61 ANSWER KEY 61 l.00 MCS D

62 ANSWER KEY 62 l.00 MCS A

63 ANSWER KEY 63 1.00 MCS C

64 ANSWER KEY 64 1.00 MCS C

65 ANSWER KEY 65 1.00 MCS B

66 ANSWER KEY 66 l.00 MCS A

67 ANSWER KEY 67 l.00 MCS C

68 ANSWER KEY 68 1.00 MCS B

69 ANSWER KEY 69 l.00 MCS B

70 ANSWER KEY 70 l.00 MCS C

71 ANSWER KEY 71 l.00 MCS B

72 ANSWER KEY 72 l.00 MCS C

73 ANSWER KEY 73 1.00 MCS D

74 ANSWER KEY 74 1.00 MCS D

75 ANSWER KEY 75 1.00 MCS B

SECTION 1 ( 75 items) 75.00 Tuesday, February 09, 2010 10:08:35 AM 2