Letter Sequence RAI |
|---|
|
Results
Other: ML072470667, ML072540790, ML072540792, ML072540793, ML072540795, ML072540797, ML072540802, ML072540803, ML072540806, ML072540807, ML072540809, ML072540811, ML072540814, ML072540816, ML072540818, ML072540819, ML072540820, ML072550056, ML072550058, ML072550059, ML072680179, ML072680188, ML072680191, ML072680192, ML072740013, ML080660133
|
MONTHYEARML0725407921968-06-0404 June 1968 Drawing 11D-190, 6 Inch Roof Vent Project stage: Other ML0725408181974-10-22022 October 1974 Drawing M-79, Rev. 3, Main Steam Relief Valve Discharge Stack Modification Project stage: Other ML0725500591984-01-0606 January 1984 Drawing M-990, Rev. 0, General Arrangement 14 Dia. Intake Line from Top of Service Bldg. to the Mechanical Room Addition Project stage: Other ML0725407931989-01-30030 January 1989 Drawing C-18, Rev, 6, Erection Diagram. Sheet 67 Project stage: Other ML0725500581991-11-11011 November 1991 Drawing M-140, Rev. 7, Penetrations Containment Building Wall Project stage: Other ML0725408191994-06-21021 June 1994 Drawing M-113, Rev. 11, Heating & Ventilation Turbine Building Plan of Elev. - 625 - 0 Project stage: Other ML0725408141996-02-23023 February 1996 Drawing M-42, Rev. 32, Piping Drawing Area 3 Sections Project stage: Other ML0725408201996-04-24024 April 1996 Drawing M-119, Rev. 7, Heating and Ventilating Mechanical Room Roof Plan Sections and Details. Sheet 3 Project stage: Other ML0725408161997-01-17017 January 1997 Drawing M-65, Rev. 13, Piping Drawing Main Steam System Project stage: Other ML0725408111997-02-27027 February 1997 Drawing M-40, Rev. 29, Piping Drawing Area 3 Plan of El. 625 - 0 & Sections Project stage: Other ML0725408091997-11-0404 November 1997 Drawing M-29, Rev. 13, Piping Drawing Area 2 Plan of El. 625 - 0 Project stage: Other ML0725500561998-01-14014 January 1998 Drawing M-119, Rev. 8, Heating and Ventilation Mechanical Equipment Room Plan and Sections El. 629 -2. Sheet 4 Project stage: Other ML0725407971998-02-25025 February 1998 Drawing C-50, Rev. 20, Architectural Auxiliary & Reactor Buildings Floor Plan at El 625-0 Project stage: Other ML0725407951998-10-0505 October 1998 Drawing C-38, Rev. 6, Field Erected Tanks. Sheet 2 Project stage: Other ML0725408061998-10-12012 October 1998 Drawing C-141, Rev. 5, Containment Ventilation Stack Project stage: Other ML0725408031999-04-0808 April 1999 Drawing C-127, Rev. 2, Containment Vessel Typical Details Project stage: Other ML0725407902006-01-11011 January 2006 Drawing C-2, Rev. 16, Plant Area and Switchyard Plan. Sheet 1 Project stage: Other ML0726801792006-01-12012 January 2006 Drawing C-52, Rev. 15, Architectural Roof Plan Project stage: Other ML0725408022006-11-15015 November 2006 Drawing C-51, Rev. 30, Architectural Auxillary & Reacator Building Floor Plans at 639 - 0 and 649-0 Project stage: Other ML0727007542006-12-0505 December 2006 Draft RAI on Alternate Source Term Amendment Project stage: Draft RAI ML0725408072007-01-12012 January 2007 Drawing M-15, Rev. 12, Equipment Location Turbine Building Sections Project stage: Other ML0705800842007-02-26026 February 2007 Draft RAI on Proposed AST Amendment Project stage: Draft RAI ML0727002592007-03-29029 March 2007 Draft RAI on Alternate Source Term (AST) Amendment Project stage: Draft RAI ENOC-07-00020, Entergy Nuclear Operations, Inc., Annual Report for Quality Assurance Program Manual Changes, Revision 162007-06-15015 June 2007 Entergy Nuclear Operations, Inc., Annual Report for Quality Assurance Program Manual Changes, Revision 16 Project stage: Request ML0726801882007-06-26026 June 2007 Drawing C-52, Rev. 23, Heating & Ventilation Auxiliary & Containment Plan at Elevation 639-0 & 649 -0 Project stage: Other ML0718005132007-06-29029 June 2007 Revision to Voluntary Response to NRC Regulatory Issue Summary 2006-15: Preparation and Scheduling of Operator Licensing Examinations Project stage: Request ML0718700072007-07-0505 July 2007 Request for Additional Information Re. Alternative Source Term Project stage: RAI ML0723203922007-08-20020 August 2007 Response to Request for Additional Information - License Amendment Request for Replacement of Containment Sump Buffer Project stage: Response to RAI ML0725407842007-09-0707 September 2007 Supplemental Information Regarding Alternative Source Term License Amendment Request Project stage: Supplement ML0726801912007-09-14014 September 2007 NAI Report Release - NAI-1149-002, Rev. 1, Determination of Atmospheric Dispersion Factors for Palisades, Enclosure 2, Revised Calculations Project stage: Other ML0726801922007-09-14014 September 2007 NAI Report Release - NAI-1 149-018, Rev. 2, Palisades Design Basis Main Steam Line Break AST Radiological Analysis, Revised Calculations Project stage: Other ML0726801762007-09-20020 September 2007 Transmittal of Supplemental Information Regarding Alternative Source Term License Amendment Request Project stage: Supplement ML0726406082007-09-21021 September 2007 Supplemental Information Regarding Alternative Source Term License Amendment Request Project stage: Supplement ML0727400132007-09-28028 September 2007 Technical Specifications, Implemented Alternative Radiological Source Term Project stage: Other ML0724706672007-09-28028 September 2007 License Amendment, Implemented Alternative Radiological Source Term Project stage: Other ML0806601332008-05-0707 May 2008 Alternative Radiological Source Term Correction Letter Project stage: Other 2006-01-11
[Table View] |
Text
From:
Peter Tam To:
jkuemin@entergy.com; Leta Brown; Mark Lilly Date:
07/05/2007 10:42:35 AM
Subject:
Palisades: Request for telecon re. Alternative Source Term (TAC MD3087)
Jim:
Our reviewer, Leta Brown, is requesting a telecon with you and others. This relates to your alternative source term license amendment request and a drawing that was part of the 06/15/2007 response (Accession No. ML071700698) to our request for additional information.
It appears to Leta that you may have used (perhaps unintentionally) two scales when putting some "dots" on this "information only" drawing and she would like to discuss the drawing with you. The following paragraph contains specifics:
We agree that the Plant Area Plan drawing is for approximation only and that the scale for postulated releases to Intakes 1 and 2 is about 1 inch = 50 feet. However, if we apply the 1 inch = 50 feet scale for the releases to Intake 3, the distances are underestimated when compared with the values provided in Table 1.8.1-1 of Enclosure 4 of the submittal dated September 25, 2006. Note that if the distances were underestimated, this would result in an underestimate of the atmospheric dispersion factors (X/Q values) and resultant doses. We understand that Plant Area Plan drawing is for information only and was probably not used to generate the distances in Table 1.8.1-1.
This e-mail does not formally request for additional information, and does not convey a formal NRC staff position. The sole purpose of this e-mail is to prepare you and others for the requested relecon. Please contact me to arrange the requested telecon.
Peter S. Tam, Senior Project Manager Plant Licensing Branch III-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation e-mail: pst@nrc.gov Tel.: 301-415-1451 Mail Envelope Properties (468D035B.43E : 12 : 35330)
Subject:
Palisades: Request for telecon re. Alternative Source Term (TAC MD3087)
Creation Date 07/05/2007 10:42:35 AM From:
Peter Tam Created By:
PST@nrc.gov Recipients Action Date & Time entergy.com Transferred 07/05/2007 10:42:58 AM jkuemin (jkuemin@entergy.com) nrc.gov OWGWPO01.HQGWDO01 Delivered 07/05/2007 10:42:41 AM LAB2 (Leta Brown)
Opened 07/05/2007 10:45:12 AM nrc.gov TWGWPO02.HQGWDO01 Delivered 07/05/2007 10:42:35
AM MRL1 (Mark Lilly)
Opened 07/05/2007 11:16:36 AM Post Office Delivered Route entergy.com OWGWPO01.HQGWDO01 07/05/2007 10:42:41 AM nrc.gov TWGWPO02.HQGWDO01 07/05/2007 10:42:35 AM nrc.gov Files Size Date & Time MESSAGE 2977 07/05/2007 10:42:35 AM Options Auto Delete:
No Expiration Date:
None Notify Recipients:
Yes Priority:
Standard ReplyRequested:
No Return Notification:
None Concealed
Subject:
No Security:
Standard To Be Delivered:
Immediate Status Tracking:
Delivered & Opened