Holtec Center, 555 Lincoln Drive West, Marlton, NJ 08053 Telephone (856) 797- 0900 HOLT EC INTERN AT I ONAL Fax (856) 797 - 0909 SPENT FUEL POOL RACKS MODIFICATIONS WITH POISON MATERIAL INSERTS IN ANO UNIT I FOR ENTERGY Holtec Report No: HI-2022867 Holtec Project No: 1196 Report Class : SAFETY RELATED 7-111S j)oeC11y74W;y- AS IJ07-
.Sgg PA6g
HOLTEC INTERNATIONAL DOCUMENT NUMBER: HI-2022867 PROJECT NUMBER: 1196 DOCUMENT ISSUANCE AND REVISION STATUS DOCUMENT NAME: SPENT FUEL POOL RACKS MODIFICATIONS WITH POISON MATERIAL INSERTS IN ANO UNIT- SPECIFIC REVISION No. _0_ REVISION No. 1 REVISION No. 2 No. Portiontt Author's Initials Date Approved Author's Date VIR # Author's Dateppro Initials Approved Initials Approved ICHAPO1 DMM 11/16/02 202651 - DMM 1/17/02 726911 1.
- 2. CHAP02 CWB 11/16/02 871854 - CWB 1/17/02 807558 CHAP03 CWB 11/16/02 504354 - CWB 1/17/02 711269 CHAP04 ST 11/16/02 788335 ST 11/21/02 816617 DMM 1/17/02 734332
- 6. CHAP06 CWB 11/16/02 406182 CWB 11/21/02 623799 CWB 1/17/02 14788
- 7. CHAP07 JZ 11/16/02 458172 - JZ 1/17/02 886712
- Chapter or section number.
Page 1 of 4
HOLTEC INTERNATIONAL DOCUMENT NUMBER: HI-2022867 PROJECT NUMBER: 1196 DOCUMENT ISSUANCE AND REVISION STATUS DOCUMENT NAME: SPENT FUEL POOL RACKS MODIFICATIONS WITH POISONWIT MAERAL POSO INSERTS MATERIAL NSETSiN NOUNI-iDOCUMENT IN ANO UNIT-1I CATEGORY: LI GENERIC [] PROJECT SPECIFIC REVISION No._3 REVISION No. _4 REVISION No. 5 Author's Date VIR # Author's Date VIR # Author's Date VIR #
No. Portiontt Initials Approved Initials Approved Initials Approved CHAPO1 DMM 2/25/03 686344 - - DMM 12/19/03 701998 AK 2/25/03 195327 - - DMM 12/19/03 754039
- 2. CHAP02 CHAP03 AK 2/25/03 962934 - - DMM 12/19/03 968723 CHAP04 DMM 2/25/03 266472 DMM 11/18/03 165227 DMM 12/19/03 122189
- 5. CHAP05 EBR 2/25/03 138108 - - - -
2/25/03 531949 - CWB 12/19/03 905606 CHAP06 AK
- 7. CHAP07 Jz tt Chapter or section number.
Page 2 of 4
HOLTEC INTERNATIONAL DOCUMENT NUMBER: HI-2022867 PROJECT NUMBER: 1196 DOCUMENT ISSUANCE AND REVISION STATUS DOCUMENT NAME: SPENT FUEL POOL RACKS MODIFICATIONS ANO u -iDOCUMENT CATEGORY: E] GENERIC ISERS POSONMAERIL N AO [] PROJECT SPECIFIC WITH POISONWiT MATERIAL INSERTS IN UNIT-1I REVISION No. 6 REVISION No. _7 REVISION No. 8 DocumentVR#VI#VI#Author's Date 'WR # Author's Date VIR # Author's Date VII#
No. Portiontt Initials Approved Initials Approved Initials Approved CHAPO0 SPA 7/5/06 620228
- 2. CHAP02 SPA 7/5/06 700869 CHAP03 SPA 7/5/06 723072 KC 7/17/06 558104 - -
CHAP04 KC 7/5/06 245294 KC 7/17/06 622989 KC 7/24/06 799666
- 5. CHAP05 EBR 7/5/06 378241 - - - -
7/5/06 382403 DMM 7/17/06 296072 KC 7/24/06 527550
- 6. CHAP06 SPA ft Chapter or section number.
Page 3 of 4
HOLTEC INTERNATIONAL DOCUMENT NUMBER: HI-2022867 PROJECT NUMBER: 1196 DOCUMENT CATEGORIZATION In accordance with the Holtec Quality Assurance Manual and associated Holtec Quality Procedures (HQPs), this document is categorized as a:
[- Calculation Package 3 (Per HQP 3.2) E Technical Report (Per HQP 3.2)(Such as a Licensing Report)
L" Design Criterion Document (Per HQP 3.4) '- Design Specification (Per HQP 3.4)
LI Other (Specify):
DOCUMENT FORMATTING The formatting of the contents of this document is in accordance with the instructions of HQP 3.2 or 3.4 except as noted below:
DECLARATION OF PROPRIETARY STATUS Nonproprietary ["] Holtec Proprietary Privileged Intellectual Property (PIP)
Documents labeled Privileged Intellectual Property contain extremely valuable intellectual/commercial property of Holtec International. They cannot be released to external organizations or entities without explicit approval of a company corporate officer. The recipient of Holtec's proprietary or Top Secret document bears full and undivided responsibility to safeguard it against loss or duplication.
Notes:
- 1. This document has been subjected to review, verification and approval process set forth in the Holtec Quality Assurance Procedures Manual. Password controlled signatures of Holtec personnel who participated in the preparation, review, and QA validation of this document are saved in the N-drive of the company's network. The Validation Identifier Record (VIR) number is a random number that is generated by the computer after the specific revision of this document has undergone the required review and approval process, and the appropriate Holtec personnel have recorded their password-controlled electronic concurrence to the document.
- 2. A revision to this document will be ordered by the Project Manager and carried out if any of its contents is materially affected during evolution of this project. The determination as to the need for revision will be made by the Project Manager with input from others, as deemed necessary by him.
- 3. Revisions to this document may be made by adding supplements to the document and replacing the "Table of Contents", this page and the "Revision Log".
Page 4 of 4
SUMMARY
OF REVISIONS Revision 0 contains the following pages:
COVER PAGE 1 page QA AND ADMINISTRATIVE INFORMATION LOG 2 page
SUMMARY
OF REVISIONS 1 pages TABLE OF CONTENTS 8 pages
1.0 INTRODUCTION
5 pages 2.0 SPENT FUEL RACK FLUX TRAP GAP POISON INSERTS 10 pages 3.0 MATERIAL CONSIDERATIONS 6 pages 4.0 CRITICALITY SAFETY EVALUATION 43 pages
-- APPENDIX 4A 25 pages 5.0 THERMAL-HYDRAULIC CONSIDERATIONS 23 pages 6.0 STRUCTURAL/SEISMIC CONSIDERATIONS 56 pages 7.0 MECHANICAL ACCIDENTS 2 pages TOTAL 182 pages Revision 1 The changes made are
- 1. Revised table 4.2.2 and 4.2.3 to reflect change of burnup requirement for 2.0% enrichment fuel (from 0 to 0.5 MWD/MTU) for spent fuel storage in Unit 1 Region 1 racks. As a result Figure 4.1.1 is also revised.
- 2. Editorial changes to Section 6 .6.2 (iii) a).
The number of pages in the documents remains unchanged from revision 0.
Revision 2 Per verbal request from ANO, editorial changes were made to align the document closely with the Unit 2 licensing submittal (HI-20222868). All the changes are marked via revision bars.
Revision 3 Incorporate editorial changes as per the E-Mail by C Walker (ANO) to Debu Mitra-Majumdar (Holtec) dated Feb 17, 2003.Only sections 1 to 6 were modified. The e-mail is stored in the Holtec server at \projects\1 196\e-mail\ANO-U 1-2022867rev2-Comments Revision 2 contains the following pages: I Holtec Report HI-2022867 RI 1196
COVER PAGE 1 age QA AND ADMINISTRATIVE INFORMATION LOG 3 page
SUMMARY
OF REVISIONS 2 pages TABLE OF CONTENTS 8 pages
1.0 INTRODUCTION
5 pages 2.0 SPENT FUEL RACK FLUX TRAP GAP POISON INSERTS 9 pages 3.0 MATERIAL CONSIDERATIONS 6 pages 4.0 CRITICALITY SAFETY EVALUATION 43 pages
-- APPENDIX 4A 26 pages 5.0 THERMAL-HYDRAULIC CONSIDERATIONS 22 pages 6.0 STRUCTURAL/SEISMIC CONSIDERATIONS 54 pages 7.0 MECHANICAL ACCIDENTS 2 pages TOTAL 181 pages Revision 4 Changes made to address comments from ANO. These were transmitted via e-mails from Christopher Walker (ANO) to D. Mitra-Majumdar (Holtec) on 11/10/03 and 11/11/03 and from Dana Miller (ANO) to D. Mitra-Majumdar (Holtec) on 11/10/03. Also, changes to the Region 3 racks criticality analysis, with stainless steel poison insert components, were also incorporated. All the changes are annotated by revision bars. Changes were made to Chapter 4 only.
Revision 5 Editorial changes made to chapters 1, 2, 3 and 4. Changes to chapter 6 include the addition of 2 new WPMR cases as described in Section 6.7. Subsections 6.8.4.3, 6.9.3.a, 6.9.4.c, and Table 6.9.1 have also been revised to reflect the additional cases. All changes are identified via revision bars.
Revision 5 contains the following pages:
COVER PAGE 1 page QA AND ADMINISTRATIVE INFORMATION LOG 3 page
SUMMARY
OF REVISIONS 2 pages TABLE OF CONTENTS 7 pages
1.0 INTRODUCTION
5 pages 2.0 SPENT FUEL RACK FLUX TRAP GAP POISON INSERTS 9 pames 3.0 MATERIAL CONSIDERATIONS 6 pages 4.0 CRITICALITY SAFETY EVALUATION 41 pages
-- APPENDIX 4A 25 pages 5.0 THERMAL-HYDRAULIC CONSIDERATIONS 22 pages 6.0 STRUCTURAL/SEISMIC CONSIDERATIONS 54 pages 7.0 MECHANICAL ACCIDENTS 2 pages TOTAL 177 pages Revision 6 Holtec Report HI-2022867 R2 1196
The principal changes in this revision are the addition of a new fuel type (HTP fuel), removal of Chapter 6, and incorporation of client comments. Editorial changes are made to chapters 1, 2, 3. Chapter 4 is replaced in its entirety.
Editorial changes are made to Chapter 5, and results are updated in this chapter to reflect the new fuel type. Previous Chapter 7 is now Chapter 6, with editorial changes.
Revision 6 contains the following pages:
COVER PAGE 1 page QA AND ADMINISTRATIVE INFORMATION LOG 4 pages
SUMMARY
OF REVISIONS 3 pages TABLE OF CONTENTS 7 pages
1.0 INTRODUCTION
5 vages 2.0 SPENT FUEL RACK FLUX TRAP GAP POISON INSERTS 9 vanes 3.0 MATERIAL CONSIDERATIONS 6 nages 4.0 CRITICALITY SAFETY EVALUATION 85 vages
-- APPENDIX 4A 25 Dues 5.0 THERMAL-HYDRAULIC CONSIDERATIONS 22 pages 6.0 MECHANICAL ACCIDENTS 2 pages TOTAL 169 pages Revision 7 The principal change in this revision is the evaluation of the Region 3 fuel storage in 3 of 4 arrangement (3 fresh and 1 spent in a 2x2 array) under the assumption that all of the Metamic panels are damaged. Also, the boron dilution analyses were modified to show dilution times for normal storage conditions only. Changes are made to chapters 4 to reflect these. Editorial changes were also made to chapter 3 and 4 per client comments.
Revision 7 contains the following pages:
COVER PAGE I page QA AND ADMINISTRATIVE INFORMATION LOG 4 pages
SUMMARY
OF REVISIONS 3 pages TABLE OF CONTENTS 7 Dages
1.0 INTRODUCTION
5 pages 2.0 SPENT FUEL RACK FLUX TRAP GAP POISON INSERTS 9 vanes 3.0 MATERIAL CONSIDERATIONS 6 pages 4.0 CRITICALITY SAFETY EVALUATION 85 pages
-- APPENDIX 4A 25 pages 5.0 THERMAL-HYDRAULIC CONSIDERATIONS 22 vanes 6.0 MECHANICAL ACCIDENTS 2 pages TOTAL 169 pages Revision 8 Holtec Report HI-2022867 R3 1196
Editorial changes are made to chapters 4 and 6.
Revision 8 contains the following pages:
COVER PAGE I page QA AND ADMINISTRATIVE INFORMATION LOG 4 pages
SUMMARY
OF REVISIONS 4 pages TABLE OF CONTENTS 7 pages
1.0 INTRODUCTION
5 pages 2.0 SPENT FUEL RACK FLUX TRAP GAP POISON INSERTS 9 3.0 MATERIAL CONSIDERATIONS 6 pages 4.0 CRITICALITY SAFETY EVALUATION 85 pages
-- APPENDIX 4A 25 pages 5.0 THERMAL-HYDRAULIC CONSIDERATIONS 22 pages 6.0 MECHANICAL ACCIDENTS 2 pages TOTAL 170 pages Holtec Report HI-2022867 R4 1196
TABLE OF CONTENTS 1.0 INTRODU CTION ............................................................................................... 1-1 1.1 References ............................................................................................................ 1-4 2.0 SPENT FUEL RACK FLUX TRAP GAP POISON INSERT ASSEMBLY D ESIGN ............................................................................................................... 2-1 2.1 Introduction .......................................................................................................... 2-1 2.2 Summ ary of Principal Design Criteria ................................................................. 2-1 2.3 Applicable Codes and Standards ......................................................................... 2-2 2.4 Quality A ssurance Program ................................................................................. 2-7 2.5 M echanical Design .............................................................................................. 2-7 2.6 Fabrication ........................................................................................................... 2-9 2.7 Installation ........................................................................................................... 2-9 3.0 M ATERIAL CON SID ERATION S ..................................................................... 3-1 3.1 Introduction .......................................................................................................... 3-1 3.2 Structural M aterials .............................................................................................. 3-1 3.3 N eutron Absorbing M aterial ................................................................................ 3-1 3.3.1 M ETAM IC M aterial Characteristics ................................................................. 3-3 3.4 Compatibility with Environm ent ......................................................................... 3-3 3.5 Heavy Load Considerations ................................................................................. 3-4 3.6 References ............................................................................................................ 3-4 4.0 CRITICA LITY SAFETY AN ALY SIS ................................................................ 4-1 4.1 Introduction and Summ ary .................................................................................. 4-1 4.2 M ethodology ........................................................................................................ 4-3 4.3 Acceptance Criteria .............................................................................................. 4-5 4.4 A ssum ptions ......................................................................................................... 4-6 4.5 Input Data ............................................................................................................ 4-6 4.5.1 Fuel A ssembly Specification ......................................................................... 4-6 4.5.2 Core Operating Parameters ............................................................................ 4-7 4.5.3 Axial Bum up D istribution ............................................................................. 4-7 4.5.4 Core Inserts .................................................................................................... 4-7 4.5.5 AN O Unit 1 Storage Rack Specification ....................................................... 4-7 4.5.5.1 Region 1 Style Storage Racks .................................................................. 4-7 4.5.5.2 Region 2 Style Storage Racks .................................................................. 4-8 4.5.5.3 Region 3 Style Storage Racks .................................................................. 4-8 4.5.5.4 Gaps Betw een A djacent Racks ................................................................ 4-9 4.6 Computer Codes ................................................................................................... 4-9 4.7 Analysis ............................................................................................................... 4-9 4.7.1 Calculational Methodologies Applicable to Region 1, Region 2 & Region 3
...................................................................................................................... 4-10 4.7.1.1 M oderator Tem perature Effect .................................................................... 4-10 4.7.1.2 Reactivity Effect of Inserts During D epletion ............................................. 4-10 4.7.1.3 Reactivity Effect of Axial Burnup Distribution ........................................... 4-11 4.7.1.4 Isotopic Com positions ................................................................................. 4-11 4.7.1.5 Uncertainty in D epletion Calculations ......................................................... 4-12 4.7.2 Region 1............................................................................................................. 4-12 Holtec Report HI-2022867 i Holtec Project 1196
TABLE OF CONTENTS 4.7.2.1 Identification of Reference Fuel Assembly.................................... 4-12 4.7.2.2 Eccentric Fuel Assembly Positioning .......................................... 4-12 4.7.2.3 Uncertainties Due to Manufacturing Tolerances.............................. 4-13 4.7.2.4 Temperature and Water Density Effects ....................................... 4-14 4.7.2.5 Calculation of Maximum k,,f................................................... 4-14 4.7.2.6 Determination of Burnup versus Enrichment Values......................... 4-15 4.7.2.7 Soluble Boron Concentration for Maximum k,,ff of 0.95 ..................... 4-15 4.7.3 Region 2............................................................................... 4-15 4.7.3.1 Identification of Reference Fuel Assembly.................................... 4-15 4.7.3.2 Eccentric Fuel Assembly Positioning .......................................... 4-16 4.7.3.3 Uncertainties Due to Manufacturing Tolerances.............................. 4-16 4.7.3.4 Temperature and Water Density Effects ....................................... 4-17 4.7.3.5 Calculation of Maximum k,,f................................................... 4-17 4.7.3.6 Determination of Burnup versus Enrichment Values......................... 4-18 4.7.3.7 Soluble Boron Concentration for Maximum k.,fr of 0.95 ..................... 4-18 4.7.4 Region 3............................................................................... 4-18 4.7.4.1 Identification of Reference Fuel Assembly.................................... 4-18 4.7.4.2 Eccentric Fuel Assembly Positioning .......................................... 4-19 4.7.4.3 Uncertainties Due to Manufacturing Tolerances.............................. 4-19 4.7.4.4 Temperature and Water Density Effects ....................................... 4-20 4.7.4.5 Calculation of Maximum kef ................................................... 4-20 4.7.4.6 Determination of the Minimum Burnup, for a Single Spent Assembly in the 3 of 4 Loading Pattern............................................................. 4-21 4.7.4.7 Soluble Boron Concentration for Maximum kff of 0.95 ..................... 4-21 4.7.5 Abnormal and Accident Conditions for Region 1, 2 & 3 Racks................. 4-21 4.7.5.1 Abnormal Temperature.......................................................... 4-22 4.7.5.2 Dropped Assembly - Horizontal................................................ 4-22 4.7.5.3 Dropped Assembly - Vertical................................................... 4-22 4.7.5.4 Abnormal Location of a Fuel Assembly ....................................... 4-23 4.7.5.4.1 Misloaded Fresh Fuel Assembly ........................................... 4-23 4.7.5.4.2 Mislocated Fresh Fuel Assembly........................................... 4-23 4.7.5.5 Loss of all Metamic.............................................................. 4-24 4.7.6 Interfaces Within and Between Racks.............................................. 4-24 4.7.6.1 Normal Conditions............................................................... 4-24 4.7.6.2 Rack Lateral Motion - Seismic Event ......................................... 4-25 4.7.7 Boron Dilution Evaluation........................................................... 4-25 4.7.7.1 Low Flow Rate Dilution......................................................... 4-26 4.7.7.2 High Flow Rate Dilution ........................................................ 4-26 4.8 New Fuel Storage Racks Criticality Analysis...................................... 4-28 4.9 Fuel Handling Equipment ........................................................... 4-29 4.10 References............................................................................. 4-30 Appendix 4A Benchmark Calculations ............................................................ 4A-1 4A. I Introduction and Summary ......................................................... 4A-1 4A.2 Effect of Enrichment ................................................................ 4A-3 4A.3 Effect of loB3 Loading................................................................ 4A-4 4A.4 Miscellaneous and Minor Parameters.............................................. 4A-5 Holtec Renort HI-2022867 ii Holtec Proiect 1196
TABLE OF CONTENTS 4A .4.1 Reflector M aterial and Spacings ................................................................. 4A -5 4A .4.2 Fuel Pellet D iam eter and Lattice Pitch ....................................................... 4A -5 4A .4.3 Soluble Boron Concentration Effects ......................................................... 4A -5 4A .5 M OX Fuel ......................................................................................................... 4A -6 4A .6 References ......................................................................................................... 4A -7 5.0 THERMAL-HYDRAULIC CONSIDERATIONS .............................................. 5-1 5.1 Introduction .......................................................................................................... 5-1 5.2 Cooling System D escription ................................................................................ 5-2 5.3 Spent Fuel Pool Decay H eat Loads ..................................................................... 5-3 5.4 Minimum Time-to-Boil and Maximum Boiloff Rate .......................................... 5-4 5.5 M aximum SFP Local W ater Tem perature ........................................................... 5-5 5.6 Fuel Rod Cladding Tem perature .......................................................................... 5-7 5.7 Results .................................................................................................................. 5-9 5.7.1 D ecay Heat ........................................................................................................... 5-9 5.7.2 Minimum Time-to-Boil and Maximum Boiloff Rate .......................................... 5-9 5.7.3 Local W ater and Fuel Cladding Tem peratures .................................................... 5-9 5.8 References .......................................................................................................... 5-10 6.0 M ECHANICAL A CCIDENTS ........................................................................... 6-1 6.1 Introduction .......................................................................................................... 6-1 6.2 Description of M echanical Accidents .................................................................. 6-1 6.3 Evaluation of M echanical A ccidents ................................................................... 6-1 6.4 Conclusion ........................................................................................................... 6-2 6.5 References ............................................................................................................ 6-2 Holtec Renort HI-2022867 It- .............
iii Holtec Proiect 1196
.......... j .......
TABLE OF CONTENTS Tables 3.3.1 Chemical Composition and Physical Properties of Aluminum (6061 Alloy) .................. 3-5 3.3.2 Chemical Composition and Physical Properties of Boron Carbide ................................. 3-6 4.5.1 PWR Fuel Assembly Specifications .............................................................................. 4-31 4.5.2 Core Operating Parameters for Depletion Analysis ...................................................... 4-32 4.5.3 Axial Bum up Profile ...................................................................................................... 4-33 4.5.4 B PR A D ata ..................................................................................................................... 4-34 4.5.5 Weight Percents of BPRA Material (3.5wt% B4C) ....................................................... 4-34 4.5.6 A P SR Data ..................................................................................................................... 4-34 4.5.7 Fuel Rack Specifications - Region 1 Racks .................................................................. 4-35 4.5.8 Fuel Rack Specifications - Region 2 Racks .................................................................. 4-36 4.5.9 Fuel Rack Specifications - Region 3 Racks .................................................................. 4-37 4.5.10 Identification of Possible Rack Interaction and Minimum Distances Between Racks.. 4-38 4.7.1 Summary of the Criticality Safety Analyses for Region 1 without Soluble Boron at 0 Y ears C ooling Tim e ....................................................................................................... 4-39 4.7.2 Summary of the Criticality Safety Analyses for Region 1 with Soluble Boron at 0 Years C ooling T ime ................................................................................................................. 4-40 4.7.3 Summary of the Criticality Safety Analyses for Region 1 without Soluble Boron for a 2x2 Checkerboard of Fresh Fuel and Empty Cells ........................................................ 441 4.7.4 Summary of the Criticality Safety Analyses for Region 1 with Soluble Boron for a 2x2 Checkerboard of Fresh Fuel and Empty Cells .......................................................... 4-42 4.7.5 Summary of the Criticality Safety Analyses for Region 2 without Soluble Boron at 0 Y ears C ooling Tim e ....................................................................................................... 4-43 4.7.6 Summary of the Criticality Safety Analyses for Region 2 with Soluble Boron at 0 Years C ooling T ime ................................................................................................................. 4-44 4.7.7 Summary of the Criticality Safety Analyses for Region 2 without Soluble Boron for a 2x2 Checkerboard of Fresh Fuel and Empty Cells ........................................................ 4-45 4.7.8 Summary of the Criticality Safety Analyses for Region 2 with Soluble Boron for a 2x2 Checkerboard of Fresh Fuel and Empty Cells ............................................................... 4-46 4.7.9 Summary of the Criticality Safety Analyses for Region 3 without Soluble Boron for a 2x2 Checkerboard of 3 Fresh Fuel Assemblies and 1 Spent Fuel Assembly at 0 Years C ooling Tim e ................................................................................................................. 4-47 4.7.10 Summary of the Criticality Safety Analyses for Region 3 with Soluble Boron for a 2x2 Checkerboard of 3 Fresh Fuel Assemblies and 1 Spent Fuel Assembly at 0 Years Cooling Tim e ............................................................................................................................... 4-4 8 4.7.11 Summary of the Criticality Safety Analyses for Region 3 without Soluble Boron ....... 4-49 4.7.12 Summary of the Criticality Safety Analyses for Region 3 with Soluble Boron ............ 4-50 4.7.13 Burmup Value at which APSRs and BPRAs have Equivalent Reactivity Effect ........... 4-51 4.7.14 Maximum Burnup versus Enrichment Values for Region 1 Racks with Spent Fuel ..... 4-52 4.7.15 Maximum Burnup versus Enrichment Values for Region 2 Racks with Spent Fuel ..... 4-53 4.7.16 Reactivity Effect of Insert Type, Enrichment 5.0 wt% 235U, 0 Cooling Time .............. 4-54 4.7.17 Reactivity Effect of Fuel and Rack Tolerances for Region 1 Racks ............................. 4-55 4.7.18 Reactivity Effect of Temperature Variation in Region 1 Racks .................................... 4-56 4.7.19 Reactivity Effect of Fuel and Rack Tolerances for Region 2 Racks ............................. 4-57 Holtec Report HI-2022867 iv Holtec Project 1196
TABLE OF CONTENTS 4.7.20 Reactivity Effect of Temperature Variation in Region 2 Racks .................................... 4-58 4.7.21 Reactivity Effect of Fuel and Rack Tolerances for Region 3 Racks ............................. 4-59 4.7.22 Reactivity Effect of Temperature Variation in Region 3 Racks .................................... 4-60 4.7.23 Region 1 Accident Conditions ....................................................................................... 4-61 4.7.24 Region 2 Accident Conditions ....................................................................................... 4-62 4.7.25 Region 3 Accident Conditions ....................................................................................... 4-63 4.7.26 Interface Calculations .................................................................................................... 4-64 4.8.1 Summary of New Fuel Vault Criticality Safety Analysis .............................................. 4-65 4A.1 Summary of Criticality Benchmark Calculations ....................................... 4A-9 thru 4A-13 4A.2 Comparison of MCNP4a and Keno5a Calculated Reactivities for V arious Enrichm ents ............................................................................................. 4A -14 4A.3 MCNP4a Calculated Reactivities for Critical Experiments w ith N eutron Absorbers .............................................................................................. 4A -15 4A.4 Comparison of MCNP4a and KENO5a Calculated Reactivities for Various I0 B L oadings ............................................................................................................... 4A -16 4A.5 Calculations for Critical Experiments with Thick Lead and Steel Reflectors ............ 4A-17 4A.6 Calculations for Critical Experiments with Various Soluble Boron C oncentrations ............................................................................................................ 4A -18 4A.7 Calculations for Critical Experiments with MOX Fuel .............................................. 4A-19 5.3.1 Key Input Data for Decay Heat Computations .............................................................. 5-11 5.3.2 Offload Schedule ........................................................................................................... 5-12 5.4.1 Key Input Data for Time-To-Boil Evaluation ............................................................... 5-13 5.5.1 Key Input Data for Local Temperature Evaluation ....................................................... 5-14 5.7.1 Result of SFP Decay Heat Calculations ........................................................................ 5-15 5.7.2 Results of Loss-of-Forced Cooling Evaluations ............................................................ 5-16 5.7.3 Results of Maximum Local Water and Fuel Cladding Temperature Evaluations ........ 5-17 Holtec Report HI-2022867 V Holtec Project 1196
TABLE OF CONTENTS Figures 1.1 Location of the Different Rack Types in the Spent Fuel Pool 2.5.1 Schematic of the Poison Insert Assembly Mechanism 2.5.2 Lead-in Device 4.5.1 A Two-Dimensional Representation of the Actual Calculational Model Used for the Region 1 Rack Analysis for Uniform Loading of Spent Fuel. This Figure was Drawn (To Scale) with the Two-Dimensional Plotter in MCNP4a.
4.5.2 A Two-Dimensional Representation of the Actual Calculational Model Used for the Region 1 Rack Analysis for Checkerboard Loading of Fresh Fuel. This Figure was Drawn (To Scale) with the Two-Dimensional Plotter in MCNP4a.
4.5.3 A Two-Dimensional Representation of the Actual Calculational Model Used for the Region 2 Rack Analysis for Uniform Loading of Spent Fuel. This Figure was drawn (To Scale) with the Two-Dimensional Plotter in MCNP4a.
4.5.4 A Two-Dimensional Representation of the Actual Calculational Model Used for the Region 2 Rack Analysis for Checkerboard Loading of Fresh Fuel. This Figure was Drawn (To Scale) with the Two-Dimensional Plotter in MCNP4a.
4.5.5 A Two-Dimensional Representation of the Actual Calculational Model Used for the Region 3 Rack Analysis for Uniform Loading of Fresh Fuel. This Figure was drawn (To Scale) with the Two-Dimensional Plotter in MCNP4a.
4.5.6 A Two-Dimensional Representation of the Actual Calculational Model Used for the Region 3 Rack Analysis for "3 of 4" Loading of Spent and Fresh Fuel. This Figure was drawn (To Scale) with the Two-Dimensional Plotter in MCNP4a.
4.5.7 A Two-Dimensional Representation of the ANO Unit 1 Spent Fuel Pool Layout with Rack Region Layout and Gaps between Adjacent Racks.
4.5.8 Sketch Illustrating Locations of Measurements of Water Gaps Between Adjacent Racks.
4.5.9 Sketch of Region 1 Racks, Detailing Important Dimensions and Tolerances.
4.5.10 Sketch of Region 2 Racks, Detailing Important Dimensions and Tolerances.
4.5.11 Sketch of Region 3 Racks, Detailing Important Dimensions and Tolerances.
4.7.1 Interface Calculation for Adjacent Region 1 Racks Containing Fresh Fuel Checkerboards with Fresh Fuel Assemblies Facing Across the Gap.
4.7.2 Fresh Fuel Checkerboard and Spent Fuel in same Region 1 Rack.
4.7.3 Interface Calculation for Adjacent Region 2 Racks Containing Fresh Fuel Checkerboards with Fresh Fuel Assemblies Facing Across the Gap.
4.7.4 Fresh Fuel Checkerboard and Spent Fuel in same Region 2 Rack.
4.7.5 Interface Calculation for Adjacent Region 3 Racks with 3 of 4 Pattern and Fresh Fuel Facing Across the Gap.
4.7.6 Interface Calculation for Region 3 Racks. Fresh Fuel in one Region 3 Rack Facing Fresh and Spent Fuel in the Adjacent Rack.
4.7.7 Interface Calculation for Region 3 Racks. All Fresh Fuel (4.35 wt%) in one Rack, 3 of 4 Pattern with Fresh Fuel Facing Gap in Adjacent Rack.
4.7.8 Interface Calculation for Region 3 Racks. All Fresh Fuel (4.35 wt%) in one Rack, 3 of 4 Pattern with Fresh and Spent Fuel Facing Gap in Adjacent Rack.
4.7.9 Interface Calculation for Region 1 and Region 3 Racks. Fresh Fuel Checkerboard in Region 1 Rack, 3 of 4 pattern in Region 3 Rack with Fresh Fuel Facing Gap.
Holtec Report HI-2022867 Vi Holtec Project 1196
TABLE OF CONTENTS 4.7.10 Interface Calculation for Region 1 and Region 3 Racks. Spent Fuel in Region 1 Rack, 3 of 4 Pattern in Region 3 Rack with Fresh Fuel Facing Gap.
4.7.11 Interface Calculation for Region 2 and Region 3 Racks. Fresh Fuel Checkerboard in Region 2 Rack, 3 of 4 pattern in Region 3 Rack with Fresh Fuel Facing Gap.
4.7.12 Interface Calculation for Region 2 and Region 3 Racks. Spent Fuel in Region 2 Rack, 3 of 4 Pattern in Region 3 Rack with Fresh Fuel Facing Gap.
4.7.13 3 of 4 Loading Pattern and Fresh Fuel (4.35 wt%) in same Region 3 Rack, All fresh 5.0 wt% facing all fresh 4.35 wt%.
4.7.14 3 of 4 Loading Pattern and Fresh Fuel (4.35 wt%) in same Region 3 Rack, Fresh and Spent 5.0 wt% facing all fresh 4.35 wt%.
4.8.1 Reactivity of the New Fuel Vault as a Function of Moderator Density for 4.95 wt% Fuel.
4.8.2 Acceptable New Fuel Storage Vault Configuration for up to 4.95 wt%/o Enrichment Fresh Fuel.
4.8.3 Acceptable New Fuel Storage Vault Configuration for up to 4.2 wt% Enrichment Fresh Fuel.
4A. 1 MCNP Calculated k-eff Values for Various Values of the Spectral Index 4A.2 KENO5a Calculated k-eff Values for Various Values of the Spectral Index 4A.3 MCNP Calculated k-eff Values at Various U-235 Enrichments 4A.4 KENO Calculated k-eff Values at Various U-235 Enrichments 4A.5 Comparison of MCNP and KENO5a Calculations for Various Fuel Enrichments 4A.6 Comparison of MCNP and KENOSa Calculations for Various Boron-10 Areal Densities 5.5.1 Schematic of the CFD Model of the ANO-1 SFP 5.7.1 Partial Core Offload Bounding Spent Fuel Pool Heat Load 5.7.2 Full Core Offload Bounding Spent Fuel Pool Heat Load 5.7.3 Contours of Static Temperature in a Vertical Plane Through the Center of the SFP 5.7.4 Velocity Vector Plot in a Vertical Plane Through the Center of the SFP Holtec Report HI-2022867 vii Holtec Project 1196
1.0 INTRODUCTION
Arkansas Nuclear One, Unit 1 (ANO-1), operated by Entergy Operations, is located approximately 70 miles northwest of Little Rock, Arkansas and about five miles west of Russellville. ANO-1 is a Babcock
& Wilcox (B&W) pressurized water reactor and has been in commercial operation since 1974. The ANO-1 reactor is licensed for a thermal power level of 2568 megawatts. The reactor core contains 177 fuel assemblies and the spent fuel pool (SFP) is licensed for the storage of 968 assemblies.
The Westinghouse designed racks in the ANO-1 SFP are free-standing and self supporting racks. The principal fabrication materials are ASTM A-240, Type 304 stainless steel for the structural members and shapes. "Boraflex," a product of BISCO (a division of Brand, Inc.) was originally used to augment reactivity control.
The ANO-1 SFP was designed to hold spent fuel assemblies (or control rod assemblies) in underwater storage for long-term decay after their removal from the reactor core. The structure is a seismic Category I, heavy walled, reinforced concrete pool, located on grade outside the containment structure.
The interior of the pool is lined with stainless steel plate (Type 304L).
The ANO-1 spent fuel racks consist of individual cells with a square pitch of 10.65 inches, each of which accommodates a single B&W 15x15 fuel assembly or equivalent. The ANO-1 SFP is divided into two regions, designated as Region 1 and Region 2. Region 1 racks employ Boraflex as the poison material and are presently qualified to store fresh fuel assemblies with enrichments of up to 4.1 weight percent (wt%) 235U. Region 2 racks are designed with flux-traps and are currently used to store spent fuel assemblies with various initial enrichments that have accumulated certain minimum burnups. The Region 2 racks do not have any poison material. Two of the Region 2 racks will be modified by the insertion of Metamic poison insert assemblies into the flux trap region to create a new region, which will be designated as Region 3. The locations of Regions 1 and 2 and proposed Region 3 in the SFP are depicted in Figure 1-1.
The poison insert assemblies have been designed to contain two borated Aluminum (Metamice) panels for neutron absorbers. The insertion of the Metamic poison assemblies into Region 3, as shown by analyses later in this report, will enable storage of fresh fuel with a maximum enrichment up to 5.0 wt%
in the ANO-1 SFP. Region 3 racks have been analyzed to establish their capability for fresh fuel storage in a 4 of 4 configuration for enrichments up to 4.35 wt% and a 3 of 4 configuration (3 fresh fuel Holtec Report HI-2022867 1-1 Holtec Project 1196
assemblies and 1 spent fuel assembly) for enrichments up to 5.0 wt%. The Region 3 flux traps will be fitted with lead-ins on the top of the flux traps, which will act to prevent any possible uplifting of the poison panel insert assembly. The lead-in devices will also help guide the fuel assemblies into the storage cells.
The existing Region 1 racks have been reanalyzed to establish new fuel storage requirements without crediting the presence of Boraflex. The Region 2 racks were also re-analyzed to establish more flexible fuel storage requirements. The racks in Region 1 and 2 have been re-analyzed to establish their capability for fresh fuel storage in a 2-of-4 checkerboard (2 fresh fuel assemblies and 2 empty cells in a 2x2 storage space) arrangement or to store spent fuel assemblies of specified enrichment-burnup limits. The New Fuel Vault and fuel handling equipment were also analyzed to confirm acceptability of fuel with initial enrichment up to 5.0 wt% 235U.
Sections 2.0 and 3.0 of this report provide an abstract of the design and material information about the poison insert assemblies.
Section 4.0 provides a summary of the methods and results of the criticality evaluations performed for the SFP storage racks in all designated Regions of the SFP, including interfacing analysis between the Regions. Credit for soluble boron in the pool has been taken, in accordance with 10CFR50.68, to assure the criticality safety of the spent fuel storage racks. The analyses show that the neutron multiplication factor (keff) for the stored fuel array is subcritical under an assumed condition of the loss of all soluble boron in the pool water. Additional analyses have been performed to demonstrate that the soluble boron requirements to maintain ker below 0.95 for both normal storage and accident conditions are satisfied. The criticality safety analysis sets the requirements on the Metamic poison insert panel length and the amount of B4C (i.e., loading density) of the Metamic inserts for the Region 3 SFP racks.
Section 4.0 also includes a summary of the criticality evaluation performed for the New Fuel Vault racks and the fuel handling equipment.
Thermal-hydraulic analyses verify that fuel cladding will not fail due to excessive thermal stress. The thermal-hydraulic analyses, which support the modification of two of the existing Region 2 racks, are described in Section 5.0.
Holtec Report HI-2022867 1-2 Holtec Project 1196
The structural qualification requires that the subcriticality of the stored fuel be maintained under all postulated mechanical accident scenarios and is presented in Section 6.0 of this report.
Results of the analyses presented in this report establish acceptable restrictions on combinations of initial enrichment and discharge burnups for Region 1 and Region 2, and show that the insertion of poison insert assemblies into the newly defined Region 3 racks will permit storage of fresh fuel assemblies in these racks. The storage racks meet all requirements of the applicable USNRC guidelines and regulations, and applicable ANSI/ANS standards (References 2 - 6). The analysis methodologies employed are a direct evolution of previous license applications reviewed and approved by the USNRC, including nuclear subcriticality, thermal-hydraulic safety and integrity following a mechanical accident.
All computer programs utilized to perform the analyses documented in Sections 2.0 through 6.0 are benchmarked and verified. These programs have been utilized by Holtec International in numerous license applications over the past decade. The analyses presented herein clearly demonstrate that the rack module arrays with the addition of the poison insert assemblies and the lead-ins possess wide margins of safety in respect to all considerations of safety specified in the OT Position Paper [3],
namely, nuclear subcriticality, thermal-hydraulic safety, and mechanical integrity.
1-3 Holtec Project 1196 Holtec Report HI-2022867 Holtec Report HI-2022867 1-3 Holtec Project 1196
1.1 REFERENCES
[1] American Society of Mechanical Engineers (ASME), Boiler & Pressure Vessel Code, Section III, 1989 Edition, Subsection NF, and Appendices.
[2] General Design Criterion 62, Prevention of Criticality in Fuel Storage and Handling.
[3] USNRC, "OT Position for Review and Acceptance of Spent Fuel Storage and Handling Applications," April 14, 1978, and Addendum dated January 18, 1979.
[4] Code of Federal Regulations 1 OCFR50.68, Criticality Accident Requirements
[5] ANSI-8.17-1984, Criticality Safety Criteria for the Handling, Storage and Transportation of LWR Fuel Outside Reactors.
[6] L. I. Kopp, "Guidance on the Regulatory Requirements for Criticality Analysis Of Fuel Storage At Light-Water Reactor Plants," USNRC Internal Memorandum L. Kopp to Timothy Collins, August 191998.
Holtec Report HI-2022867 1-4 Holtec Project 1196
Region 2 Rack With the Flux Traps Region 2 Rack With theFlux Traps 11x12- -11x121 Region 3 Racks With Inserted Metamic Poison Panels Region 1 Rack with Boraflex Figure 1.1: Location of the Different Rack Types in the Spent Fuel Pool.
Holtec Report HI-2022867 1-5 Holtec Project 1196
2.0 SPENT FUEL RACK FLUX TRAP GAP POISON INSERT ASSEMBLY DESIGN
2.1 INTRODUCTION
Metamic poison insert assemblies containing a high loading of the B4C (nominally 25% by weight) will be inserted into the flux traps of the Region 3 storage racks to provide appropriate neutron attenuation between adjacent storage cells. Design inputs and overview applicable to the Metamic poison insert assemblies and lead-in devices are addressed within this Section. A brief description of the poison insert assembly fabrication and installation is also provided in this Section.
2.2
SUMMARY
OF PRINCIPAL DESIGN CRITERIA The key design criteria for the spent fuel racks are set forth in the USNRC memorandum entitled "OT Position for Review and Acceptance of Spent Fuel Storage and Handling Applications," dated April 14, 1978 as modified by amendment dated January 18, 1979. The individual sections of this report expound on the specific design bases derived from the above-mentioned "OT Position Paper." The thermal-hydraulic, criticality safety and mechanical accidents design bases for the spent fuel racks with the poison insert assemblies in them are summarized below:
- a. Thermal-Hydraulic Compliance: The spatial average bulk pool temperature is required to remain below 150 OF. No localized boiling is permitted.
- b. Criticality Compliance: The New Fuel Storage Racks (NFSR) and Spent Fuel Storage Racks (SFSR) must be able to store fuel of 5.0 weight percent maximum enrichment while maintaining the reactivity (kff) less than the applicable regulatory limit. For fuel in the SFSR, appropriate credit is taken for soluble boron as allowed by 10CFR 50.68.
- c. Accident Events: In the event of postulated drop events (uncontrolled lowering of a fuel assembly, for instance), it is necessary to demonstrate that the racks containing fuel assemblies remain subcritical.
The foregoing design bases are further articulated in Sections 4.0 through 6.0 of this report.
Holtec Report HI-2022867 2-1 Holtec Project 1196
2.3 APPLICABLE CODES AND STANDARDS The following codes, standards and practices are used as applicable for the design, construction, and assembly of the poison insert assemblies and lead-in devices. Additional specific references related to detailed analyses are given in each section.
- a. Design Codes (1) American Society for Nondestructive Testing SNT-TC-IA, June 1984, Recommended Practice for Personnel Qualifications and Certification in Non-destructive Testing.
(2) American Society of Mechanical Engineers (ASME) Y14.5M, Dimensioning and Tolerancing (3) ASME B & PV Code, Section II-Part D, 1998 Edition.
(4) ASME, Boiler and Pressure Vessel Code, Section III, Subsection NF, 1983 Edition, No Addenda.
(5) ASME, Boiler and Pressure Vessel Code, Section II - Parts A and C, 1983 Edition, No Addenda.
- b. Standards of American Society for Testinq and Materials (ASTM)
(1) ASTM A240 - Standard Specification for Heat-Resisting Chromium and Chromium-Nickel Stainless Steel Plate, Sheet and Strip for Pressure Vessels.
(2) ASTM A262 - Standard Practices for Detecting Susceptibility to Intergranular Attack in Austenitic Stainless Steel.
(3) ASTM C750 - Standard Specification for Nuclear-Grade Boron Carbide Powder.
(4) ASTM A380 - Standard Practice for Cleaning, Descaling, and Passivation of Stainless Steel Parts, Equipment and Systems.
(5) ASTM C992 - Standard Specification for Boron-Based Neutron Absorbing Material Systems for Use in Nuclear Spent Fuel Storage Racks.
(6) ASTM E3 - Standard Practice for Preparation of Metallographic Specimens.
(7) ASTM E190 - Standard Test Method for Guided Bend Test for Ductility of Welds.
Holtec Report HI-2022867 2-2 Holtec Project 1196
- c. Welding Code (1) ASME B & PV Code, Section IX - Welding and Brazing Qualifications, latest applicable edition and addenda.
(2) ASME, Boiler and Pressure Vessel Code, Section III, Subsection NF, 1989 Edition, No Addenda.
- d. Quality Assurance, Cleanliness, Packaging, Shipping, Receiving, Storage, and Handling (1) ANSI N45.2.1 - Cleaning of Fluid Systems and Associated Components during Construction Phase of Nuclear Power Plants - 1980 (Regulatory Guide (RG) 1.37).
(2) ANSI N45.2.2 - Packaging, Shipping, Receiving, Storage and Handling of Items for Nuclear Power Plants - 1978 (RG 1.38).
(3) ANSI N45.2.6 - Qualifications of Inspection, Examination, and Testing Personnel for the Construction Phase of Nuclear Power Plants - 1973.
(RG 1.58).
(4) ANSI N45.2.8 - Supplementary Quality Assurance Requirements for Installation, Inspection and Testing of Mechanical Equipment and Systems for the Construction Phase of Nuclear Plants - 1975 (RG 1.116).
(5) ANSI N45.2.11 - Quality Assurance Requirements for the Design of Nuclear Power Plants - 1978 (RG 1.64).
(6) ANSI N45.2.12 - Requirements for Auditing of Quality Assurance Programs for Nuclear Power Plants - 1977 (RG 1.144).
(7) ANSI N45.2.13 - Quality Assurance Requirements for Control of Procurement of Items and Services for Nuclear Power Plants - 1976 (RG 1.123).
(8) ANSI N45.2.23 - Qualification of Quality Assurance Program Audit Personnel for Nuclear Power Plants - 1978 (RG 1.146).
(9) ASME B & PV Code, Section V, Nondestructive Examination, 1983 Edition.
(10) ANSI N16.9 Validation of Calculation Methods for Nuclear Criticality Safety.
(11) ASME NQA Quality Assurance Program Requirements for Nuclear Facilities.
2-3 Holtec Project 1196 Holtec Report Holtec HI-2022867 Report HI-2022867 2-3 Hottec Project 1196
(12) ASME NQA Quality Assurance Requirements for Nuclear Power Plants.
- e. USNRC Documents (1) "OT Position for Review and Acceptance of Spent Fuel Storage and Handling Applications," dated April 14, 1978, and the modifications to this document of January 18, 1979.
(2) NUREG 0612, "Control of Heavy Loads at Nuclear Power Plants,"
USNRC, Washington, D.C., July, 1980.
(3) NUREG 0800, "Standard Review Plan for the Review of Safety Analysis Reports for Nuclear Power Plants," USNRC, Washington, D.C., July 1981.
(4) NUREG-1233, Seismic Design Criteria.
- f. Other ANSI Standards (not listed in the precedingq)
(1) ANSI/ANS 8.1/N16.1 - Nuclear Criticality Safety in Operations with Fissionable Materials Outside Reactors, 1975.
(2) ANSI N45.2.9 - Requirements for Collection, Storage and Maintenance of Quality Assurance Records for Nuclear Power Plants - 1974.
(3) ANSI N45.2.10 - Quality Assurance Terms and Definitions - 1973.
(4) ANSI/ASME N626 Qualification and Duties of Specialized Professional Engineers, 1977.
- g. Code-of-Federal Regulations (CFR)
(1) 10 CFR 20 - Standards for Protection Against Radiation.
(2) 10 CFR 21 - Reporting of Defects and Non-compliance.
(3) 10 CFR 50 Appendix A - General Design Criteria for Nuclear Power Plants.
(4) 10 CFR 50 Appendix B - Quality Assurance Criteria for Nuclear Power Plants and Fuel Reprocessing Plants.
(5) 10 CFR 100 - Reactor Site Criteria Holtec Report HI-2022867 2-4 Hottec Project 1196
- h. Regulatory Guides (RG)
(1) RG 1.13 - Spent Fuel Storage Facility Design Basis (Revision 2 Proposed).
(2) RG 1.25 - Assumptions Used for Evaluating the Potential Radiological Consequences of a Fuel Handling Accident in the Fuel Handling and Storage Facility for Boiling and Pressurized Water Reactors, Rev. 0 -
March, 1972.
(3) RG 1.28 - Quality Assurance Program Requirements - Design and Construction, Rev. 2 - February 1979 (endorses ANSI N45.2).
(4) RG 1.33 - Quality Assurance Program Requirements.
(5) RG 1.31 - Control of Ferrite Content in Stainless Steel Weld Metal, Rev.
3.
(6) RG 1.37 - Cleaning of Fluid Systems and Associated Components during Construction Phase of Nuclear Power Plants.
(7) RG 1.38 - Quality Assurance Requirements for Packaging, Shipping, Receiving, Storage and Handling of Items for Water-Cooled Nuclear Power Plants, Rev. 2 - May, 1977 (endorses ANSI N45.2.2).
(8) RG 1.44 - Control of the Use of Sensitized Stainless Steel.
(9) RG 1.58 - Qualification of Nuclear Power Plant Inspection, Examination, and Testing Personnel, Rev. 1 - September 1980 (endorses ANSI N45.2.6)
(10) RG 1.64 - Quality Assurance Requirements for the Design of Nuclear Power Plants, Rev. 2 - June, 1976 (endorses ANSI N45.2.11).
(11) RG 1.71 - Welder Qualifications for Areas of Limited Accessibility.
(12) RG 1.74 - Quality Assurance Terms and Definitions, Rev. 2 - February, 1974 (endorses ANSI N45.2.10).
(13) RG 1.85 - Materials Code Case Acceptability - ASME Section III, Division 1.
(14) RG 1.88 - Collection, Storage and Maintenance of Nuclear Power Plant Quality Assurance Records, Rev. 2 - October, 1976 (endorses ANSI N45.2.9).
(15) RG 1.116 - Quality Assurance Requirements for Installation, Inspection and Testing of Mechanical Equipment and Systems, Rev. 0-R - May,1977 (endorses ANSI N45.2.8-1975)
Holtec Report HI-2022867 2-5 Holtec Project 1196
(16) RG 1.123 - Quality Assurance Requirements for Control of Procurement of Items and Services for Nuclear Power Plants, Rev. 1 - July, 1977 (endorses ANSI N45.2.13).
(17) RG 1.144 - Auditing of Quality Assurance Programs for Nuclear Power Plants, Rev.1 - September, 1980 (endorses ANSI N45.2.12-1977)
(18) RG 8.8 - Information Relative to Ensuring that Occupational Radiation Exposures at Nuclear Power Stations will be as Low as Reasonably Achievable (ALARA).
(19) RG 8.38 - Control of Access to High and Very High Radiation Areas in Nuclear Power Plants, June, 1993.
Branch Technical Position (1) CPB 9.1 Criticality in Fuel Storage Facilities.
- j. American Welding Society (AWS) Standards (1) AWS D1.1 - Structural Welding Code - Steel.
(2) AWS D1.3 - Structure Welding Code - Sheet Steel.
(3) AWS D9.1 - Sheet Metal Welding Code.
(4) AWS A2.4 - Standard Symbols for Welding, Brazing and Nondestructive Examination.
(5) AWS A3.0 - Standard Welding Terms and Definitions.
(6) AWS A5.12 - Specification for Tungsten and Tungsten Alloy Electrodes for Arc-Welding and Cutting (7) AWS QC1 - Standard for AWS Certification of Welding Inspectors.
(8) AWS 5.4 - Specification for Stainless Steel Electrodes for Shielded Metal Arc Welding.
(9) AWS 5.9 - Specification for Bare Stainless Steel Welding Electrodes and Rods.
- k. Other References (1) ANO Unit 1 Operating License and Technical Specifications, License No.
(2) ANO Unit 1 Updated Final Safety Analysis Report (UFSAR).
Holtec Report HI-2022867 2-6 Holtec Project 1196
(3) IE Information Notice 83-29 - Fuel Binding Caused by Fuel Rack Deformation.
2.4 QUALITY ASSURANCE PROGRAM The governing quality assurance requirements for design and fabrication of the poison insert assemblies are stated in 10 CFR 50 Appendix B. Holtec's Nuclear Quality Assurance program complies with this regulation and is designed to provide a system for the design, analysis, and licensing of customized components in accordance with various codes, specifications, and regulatory requirements. The lead-in devices are classified as not important to safety and are not subject to a 10 CFR 50 Appendix B program.
The Quality Assurance System that will be used by Entergy Operations to install the poison insert assemblies and lead-in devices is controlled by the Entergy Quality Assurance Program.
2.5 MECHANICAL DESIGN The mechanical design of the poison insert assembly consists of two poison panels separated by a mechanism to maintain the water gap specified by criticality considerations. The poison panels are independent flat panels sized to cover the active fuel region. The poison panels will extend all the way to the SFP rack base plate. The poison panel will be nominally 0.10 inches thick 6061 aluminum metal matrix composite (MMC) with ASTM C-750 isotopically-graded boron carbide (B4 C) manufactured by Metamic.
The poison panels will be held together with a frame that is fabricated from SA240-304 stainless steel. A schematic of the arrangement is shown in Figure 2.5.1. Each poison insert assembly is composed of two interconnected rectangular Metamic poison panel assemblies. Each Metamic poison panel assembly includes a Metamic poison panel protected and held in place by stainless steel sheathing bands. Full-length sheathing covers the side of the Metamic panel facing the flux trap wall. This will prevent any direct contact between the Metamic panel and the flux trap wall. Additional stainless steel bands connect the two Metamic poison panel sub-assemblies together. The poison insert assembly includes a hook/wedge mechanism. The hook/wedge mechanism along with some metallic shims, connecting the full-length sheathings covering the Metamic pieces, maintains the required poison insert assembly width prior to and after installation in the flux trap. The poison insert assemblies are designed based on worst-Holtec Report HI-2022867 2-7 Holtec Project 1196
case measured dimensions of the flux trap and maximizing use of the allowable space in each flux trap for criticality safety purposes.
<21b-.:, ý IlL>
- 1 V
Figure 2.5.1 Schematic of the Poison Insert Assembly Mechanism The lead-in device, which is depicted in Figure 2.5.2, is fabricated from SA240-304L stainless steel. The device is designed to rest on top of the flux trap, and it is secured in place by two slotted plates, which straddle the cell wall at the corners external to the flux trap. The size and shape of the lead-in is such that it will not interfere with the square opening of the cell. The lead-in contains flow holes in the mounting plate to provide an uninterrupted flow path for the water entering at the bottom of the flux trap and exiting at the top of the flux trap. Each poison insert assembly and lead-in device together weighs less than 50 lbs.
Figure 2.5.2 Lead-in Device Holtec Report HI-2022867 2-8 Holtec Project 1196
2.6 FABRICATION This section provides a brief description of the poison insert assembly construction activities.
The pertinent methods used in manufacturing the poison insert assemblies may be stated as follows:
- 1. The poison panels are extruded and rolled from a powder metallurgy billet then cut to the specified rectangular size.
- 2. The fabrication process involves operational sequences that permit immediate accessibility for verification by the inspection staff.
- 3. The poison insert assemblies are fabricated per the manufacturer's Appendix B Quality Assurance program, which ensures and documents that the fabricated poison insert assemblies meet all of the requirements of the design and fabrication documents.
2.7 INSTALLATION The poison insert assembly is placed in an upending cradle on the fuel bridge. The poison insert assembly is then upended and connected to the poison insert assembly handling tool. All installation activities will be performed remotely, from the fuel bridge, using long handled installation tools. Subsequent to the upending process, the poison insert assembly is lowered into the spent fuel pool and guided into the appropriate flux trap with installation tools. Then, the lead-ins are installed onto a flux trap that received a poison insert assembly.
Holtec Report HI-2022867 2-9 Holtec Project 1196
3.0 MATERIAL CONSIDERATIONS
3.1 INTRODUCTION
Safe storage of nuclear fuel in the pool requires that the materials utilized in the poison inserts be of proven durability and compatible with the pool water environment. This section provides a synopsis of the considerations with regard to long-term design service life of 40 years.
3.2 STRUCTURAL MATERIALS The only structural material utilized in the fabrication of the poison inserts is SA240 Type 304 stainless steel.
3.3 NEUTRON ABSORBING MATERIAL In addition to the structural materials, the poison inserts employ Metamic, a patented product of Metamic, Inc., as the neutron absorber material. Metamic has been approved by USNRC for use in spent fuel pool applications [3.3.41. A brief description of Metamic follows.
Metamic is a neutron absorber material developed by the Reynolds Aluminum Company in the mid-1990s for spent fuel reactivity control in dry and wet storage applications [3.3.1]. Metallurgically, Metamic is a metal matrix composite (MMC) consisting of a high purity 6061 aluminum matrix reinforced with Type 1 ASTM C750-89, isotopically graded boron carbide (B4C). Metamic is characterized by an extremely fine aluminum spherical powder (325 mesh or better) and boron carbide powder (average particle size under 25 microns). The high performance reliability of Metamic derives from the particle size distribution of its constituents, namely, high purity aluminum 6061 alloy powder and isotopically graded B4 C particulate, rendered into an isotropic metal matrix composite state by the powder metallurgy process which yields excellent homogeneity, and which prevents B4C from clustering in the final product.
The powders are carefully blended together without binders, chelating agents, or other additives that could potentially become retained in the final product and deleteriously influence performance. The nominal percentage of B4C that will be dispersed in the aluminum alloy 6061 matrix is 25% by weight.
Holtec Report HI-2022867 3-1 Holtec Project 1196
The pure blend of powders is isostatically compacted to form a high density "green" billet. This green billet is then vacuum sintered to produce the final hard billet of nearly full theoretical density.1 Once the aluminum and the boron carbide powders are thoroughly mixed, pressed, and sintered, there is no credible mechanism that could alter the composition of Metamic. An extrusion process is used to bring the matrix into final density. Billets can vary in diameter, size and weight depending on a number of variables including loading and final panel dimensions.
Metamic has been subjected to an extensive array of tests sponsored by the Electric Power Research Institute (EPRI) that evaluated the functional performance of the material at elevated temperatures (up to 900 OF) and radiation levels (1 E+1 1 rads gamma). The results of the tests documented in an EPRI report [3.3.2] indicate that Metamic maintains its physical and neutron absorption properties with little variation in its properties from the unirradiated state. The main conclusions provided in the above-referenced EPRI report are summarized below:
" The isotropic metal matrix configuration produced by the powder metallurgy process with a complete absence of interconnected internal porosity in Metamic ensures that its density is essentially equal to the maximum theoretical density.
" Measurements of boron carbide particle distribution show extremely small particle-to-particle distance 2 and near-perfect homogeneity.
" The physical and neutronic properties of Metamic are essentially unaltered under exposure to elevated temperatures (750 OF - 900 IF).
" No detectable change in the neutron attenuation characteristics under accelerated test conditions has been observed.
The density of Metamic before hot work is 82% to 98% of theoretical density depending on B4C content.
2 Medium measured neighbor-to-neighbor distance is 10.08 microns according to the article, "METAMIC Neutron Shielding" [3.3.3].
Holtec Report HI-2022867 3-2 Holtec Project 1196
Independent tests and investigations by Holtec International [3.3.5] confirm the conclusions summarized above, and present additional data on the fundamental characteristics of Metamic and the applicability of the material in wet storage applications.
Holtec International's Q.A. program ensures that Metamic is manufactured under the control and surveillance of a Quality Assurance/Quality Control Program that conforms to the requirements of 10 CFR 50 Appendix B, "Quality Assurance Criteria for Nuclear Power Plants."
3.3.1 METAMIC Material Characteristics Aluminum: Aluminum is a silvery-white, ductile metallic element. The 6061 alloy aluminum is used extensively in heat exchangers, pressure and storage tanks, chemical equipment, reflectors, and sheet metal work.
It has high resistance to corrosion in industrial and marine atmospheres. Aluminum has atomic number of 13, atomic weight of 26.98, specific gravity of 2.69 and valence of 3. The physical, mechanical and chemical properties of the 6061 alloy aluminum are listed in Table 3.3.1.
The excellent corrosion resistance of the 6061 alloy aluminum is provided by the protective oxide film that quickly develops on its surface from exposure to the atmosphere or water. This film prevents the loss of metal from general corrosion or pitting corrosion.
Boron Carbide: The boron carbide contained in Metamic is a fine granulated powder that conforms to ASTM C750-89 nuclear grade Type I. The material conforms to the chemical composition and properties listed in Table 3.3.2.
References [3.3.1] and [3.3.2] provide further discussion as to the suitability of these materials for use in spent fuel storage applications.
3.4 COMPATIBILITY WITH ENVIRONMENT All materials used in the construction of the poison inserts have been determined to be compatible with the ANO-1 SFP, and have an established history of in-pool usage. Austenitic stainless steel (e.g., Type Holtec Report HI-2022867 3-3 Holtec Project 1196
304) is a widely used stainless alloy in nuclear power plants, and it has an established history of in-pool usage. Metamic is likewise an excellent material for spent fuel applications based on its high resistance to corrosion and its functional performance at elevated temperatures and radiation levels.
3.5 HEAVY LOAD CONSIDERATIONS There are no heavy loads involved in the proposed installation of poison inserts. The weight of a single poison insert and a lead-in is less than 50 pounds.
3.6 REFERENCES
[3.3.1] "Use of METAMIC in Fuel Pool Applications," Holtec International, HI-2022871, Revision 1, August 2002.
[3.3.2] "Qualification of METAMIC for Spent Fuel Storage Application," EPRI, 1003137, Final Report, October 2001.
[3.3.3] K. Anderson et al., "METAMIC Neutron Shielding," EPRI Boraflex Conference, November 19-20,1998.
[3.3.41 Safety Evaluation By The Office Of Nuclear Reactor Regulation Related To Holtec International Report HI-2022871 Regarding Use Of Metamic- In Fuel Pool Applications, Facility Operating License Nos. DPR-51 and NPF-6, Entergy Operations, Inc., Arkansas Nuclear One, Unit Nos. 1 and 2, Docket Nos. 50-313 and 50-368
[3.3.5] "Sourcebook for Metamic Performance Assessment", Holtec International, HI-2043215, Revision 1, February 2005 H1-2022867 3-4 Holtec Project 1196 Holtec Report HI-2022867 Holtec Report 3-4 Holtec Project 1196
Table 3.3.1 Chemical Composition and Physical Properties of Aluminum (6061 Alloy)
Chemical Composition 0.8-1.2% Magnesium 0.40-0.8% Silicone 0.15-0.40% Copper 0.15% max. Iron 0.25% max. Zinc 0.15% max. Titanium 50 ppm max. Nickel 10 ppm max. Cobalt 10 ppm max. Manganese 10 ppm max. Chromium 0.15% max. Other Remainder Aluminum Physical Properties Density 0.098 lb/in 3 3
2.71 g/cm Melting Range 1080 OF - 1205 OF 582 °C - 652 °C Thermal Conductivity (77 OF) 1250 BTU/hr-ft2 -°F/in 1.55 kcal/hr-cm 2-°C/cm 3-5 Holtec Project 1196 Report H Holtec Report 1-2022867 HI-2022867 3-5 Holtec Project 1196
Table 3.3.2 Chemical Composition and Physical Properties of Boron Carbide Chemical Composition (Weight Percent)
Total boron 76.5 min.
B10 isotope 19.9 +/- 0.30 a/o HNO 3 soluble boron 0.59* max.
Water soluble boron 0.29 max.
Fluoride 25 ppm max.
Chloride 57 ppm max.
Calcium 0.3 max.
Iron 0.5 max.
Total boron plus total carbon 98.0 min.
Physical Properties Chemical formula B4 C Crystal structure rhombohedral Density 0.0907 lb/in 3 3
2.51 g/cm Melting Point 4442 OF 2450 °C Boiling Point 6332 OF 3500 °C
- From tests presented in Reference 3.3.1 Holtec Report HI-2022867 3-6 Holtec Project 1196
4.0 CRITICALITY SAFETY ANALYSIS 4.1 Introduction and Summary This section documents the criticality safety evaluation for the storage of PWR fresh and spent nuclear fuel in Region 1, 2 & 3 style high-density spent fuel storage racks at the ANO Unit 1 nuclear power plant operated by Entergy. This section also documents the criticality safety evaluation for the storage of fresh fuel in the new fuel vault (NFV) at the ANO Unit 1 nuclear power plant.
The objective of the spent fuel pool analysis is to ensure that the effective neutron multiplication factor (k.ff) is less than or equal to 0.95 with the storage racks fully loaded with fuel of the highest permissible reactivity and the pool flooded with borated water at a temperature corresponding to the highest reactivity. In addition, it is demonstrated that keff is less than 1.0 under the assumed loss of soluble boron in the pool water, i.e., assuming unborated water in the spent fuel pool. The maximum calculated reactivities include a margin for uncertainty in reac-tivity calculations, including manufacturing tolerances, and are calculated with a 95%
probability at a 95% confidence level [4.1]. Reactivity effects of abnormal and accident conditions have also been evaluated to assure that under all credible abnormal and accident conditions, the reactivity will not exceed the regulatory limit of 0.95.
The ANO Unit 1 spent fuel pool currently contains two unique types of racks:
- 1. Region 1 racks: These racks were originally designed with Boraflex as the poison material in a flux-trap configuration.
- 2. Region 2 racks: These racks are designed to store spent fuel assemblies of a specified combination of initial enrichment and discharge burnup. These racks do not currently contain neutron absorber material.
Due to the Boraflex degradation in the Region 1 racks, future credit for Boraflex in these racks is not feasible. The proposed resolution is to re-evaluate the criticality safety of the Region 1 racks without credit for Boraflex. Additionally, some of the Region 2 racks will be modified by placing a neutron absorbing poison insert assembly into the existing Region 2 rack water gaps between storage cells. These modified Region 2 racks are identified as Region 3 racks. The new Region 3 racks will enable unrestricted storage of fresh fuel up to 4.35 wt% 235U or a "3 of 4" pattern with 3 fresh fuel assemblies with enrichments up to 5.0 wt% 235U and a single assembly with a maximum nominal initial enrichment of 5.0 wt% 235U and a specified minimum burnup requirement.
Specifically, the following evaluations were performed for the ANO Unit 1 spent fuel pool:
The Region I racks were evaluated for storage of spent fuel assemblies with specific burnup requirements as a function of initial enrichment between 2.0 wt% and 5.0 wt%
Holtec Report HI-2022867 4-1 Holtec Project 1196
23 5 U and decay times between 0 and 20 years. Results are summarized in Table 4.7.14 and calculation of the maximum keff for 5.0 wt% 235U at 0 years cooling time is given in Table 4.7.1 with no soluble boron and Table 4.7.2 with soluble boron.
- The Region 1 racks were evaluated for storage of fresh fuel assemblies with a maximum nominal enrichment of 5.0 wt% 235U in a checkerboard configuration with empty storage cells. Calculation of the maximum krff is presented in Table 4.7.3 for the case without soluble credit and in Table 4.7.4 for the case with soluble boron credit.
- The Region 2 racks were evaluated for storage of spent fuel assemblies with specific burnup requirements as a function of initial enrichment between 2.0 wt% and 5.0 wt0 /o 235U and decay times between 0 and 20 years. Results are summarized in Table 4.7.15 and calculation of the maximum k&ff for 5.0 wt/ 235U at 0 years cooling time is given in Table 4.7.5 with no soluble boron and Table 4.7.6 with soluble boron.
- The Region 2 racks were evaluated for storage of fresh fuel assemblies with a maximum nominal enrichment of 5.0 wt% 235U in a checkerboard configuration with empty storage cells. Calculation of the maximum keff is presented in Table 4.7.7 for the case without soluble credit and in Table 4.7.8 for the case with soluble boron credit.
- The Region 3 racks were evaluated for storage of fresh and spent fuel assemblies in a 3 of 4 configuration of 3 fresh fuel assemblies with a maximum nominal enrichment of 5.0 wt% 2 35U and 1 spent fuel assembly with a maximum nominal initial enrichment of 5.0 wt% 235U that has accumulated a minimum specified burnup. Calculation of the maximum k.ff is given in Table 4.7.9 with no soluble boron and Table 4.7.10 with soluble boron.
- The Region 3 racks were evaluated for unrestricted storage of fresh fuel assemblies with a maximum nominal enrichment of 4.35 wt% 235U. Calculation of the maximum krf is presented in Table 4.7.11 for the case without soluble credit and in Table 4.7.12 for the case with soluble boron credit.
Reactivity effects of abnormal and accident conditions have also been evaluated. A summary of the types of accidents analyzed and the soluble boron required to ensure that the maximum kea remains below 0.95 are shown in Table 4.7.23, Table 4.7.24 and Table 4.7.25 for Region 1, Region 2 and Region 3, respectively. The most limiting accident condition involves placing a fresh fuel assembly, enriched to 5.0 wt% 235 U, outside the storage rack, adjacent to other fuel assemblies in the rack. A minimum soluble boron concentration of 889 ppm must be maintained in the spent fuel pool to ensure that the maximum k.ff is less than 0.95 under accident conditions.
In addition to the analysis for each individual rack detailed above, the possibility of an increased reactivity effect due to the rack interfaces within and between the racks was analyzed. Table 4.7.26 provides a summary of the various interface calculations performed for the ANO Unit 1 spent fuel pool. Interfaces within the rack include spent and fresh fuel loading patterns within the same rack to determine acceptability. Interface calculations between racks include Region 1-Region 1, Region 2-Region 2, Region 3-Region 3, Region 1-Region 3 and Region 2-Region 3.
The calculated reactivity from the interface calculation is then compared to the calculated reactivity from the reference infinite array calculations. From the summary of the results in Holtec Report HI-2022867 4-2 Holtec Project 1196
Table 4.7.26 the following conclusions may be drawn regarding the reactivity effect of the interfaces:
" In the Region 1 and Region 2 racks, a fresh fuel checkerboard and uniform spent fuel loading may be placed in the same rack.
- In Region 1 and Region 2 racks, if adjacent racks contain a checkerboard of fresh fuel assemblies, the checkerboard must be maintained across the gap, i.e., fresh fuel assemblies may not face each other across a gap.
- In Region 3, uniform loading of fresh fuel at 4.35 wt% 2 35U may be combined with 3 of 4 loading in the same rack as long as a row of fresh and spent fuel in the 3 of 4 loading pattern faces the uniform loading of all fresh fuel at 4.35 wt% 235U.
- If adjacent Region 3 racks contain different loading patterns (one rack contains all fresh fuel at 4.35 wt% and the other rack contains a 3 of 4 loading pattern), both fresh and spent fuel must be in the outer row of the rack containing the 3 of 4 pattern.
- If adjacent Region 3 racks both contain 3 of 4 loading patterns, both racks may not have fresh fuel facing the other rack. Calculations with both Region 3 racks containing 3 of 4 patterns with all fresh fuel in the outer row of one rack and fresh and spent fuel in the outer row of the second rack shows a slight increase in reactivity (Ak = +0.0017) compared to the reference case. This increase is accommodated by the margin in the calculations (max k.ff for Region 3 racks with 3 of 4 pattern is 0.9958). Therefore, this condition is allowed.
- All interfaces between dissimilar racks (Region 1-Region 3 and Region 2-Region 3) do not result in an increase in the reactivity, and therefore, are permitted. Calculations were performed 2 35 with a 3 of 4 loading pattern in the Region 3 racks, with fresh fuel (5.0 wt%
U) in the outer row facing the other rack. This is bounding for the Region 3 rack containing all fresh fuel at 4.35 wt%, because the analyzed cases have higher reactivity fuel in the outer row of the rack.
4.2 METHODOLOGY The principal method for the criticality analysis of the high-density storage racks is the three-dimensional Monte Carlo code MCNP4a [4.3]. MCNP4a is a continuous energy three-dimensional Monte Carlo code developed at the Los Alamos National Laboratory. MCNP4a was selected because it has been used previously and verified for criticality analyses and has all of the necessary features for this analysis. MCNP4a calculations used continuous energy cross-section data based on ENDF/B-V and ENDF/B-VI. Exceptions are two lumped fission products calculated by the CASMO-4 depletion code that do not have corresponding cross sections in MCNP4a. For these isotopes, the CASMO-4 cross sections are used in MCNP4a. This approach has been validated [4.4] by showing that the cross sections result in the same reactivity effect in both CASMO-4 and MCNP4a.
Benchmark calculations, presented in Appendix 4A, indicate a bias of 0.0009 with an uncertainty of
+/- 0.0011 for MCNP4a, evaluated with a 95% probability at the 95% confidence level [4.1]. The Holtec Report HI-2022867 4-3 Holtec Project 1196
calculations for this analysis utilize the same computer platform and cross-section libraries used for the benchmark calculations discussed in Appendix 4A.
The convergence of a Monte Carlo criticality problem is sensitive to the following parameters:
(1) number of histories per cycle, (2) the number of cycles skipped before averaging, (3) the total number of cycles and (4) the initial source distribution. The MCNP4a criticality output contains a great deal of useful information that may be used to determine the acceptability of the problem convergence. This information has been used in parametric studies to develop appropriate values for the aforementioned criticality parameters to be used in storage rack criticality calculations. Based on these studies, a minimum of 10,000 histories were simulated per cycle, a minimum of 100 cycles were skipped before averaging, a minimum of 150 cycles were accumulated, and the initial source was specified as uniform over the fueled regions (assemblies). Further, the output was reviewed to ensure that each calculation achieved acceptable convergence. These parameters represent an acceptable compromise between calculational precision and computational time.
Fuel depletion analyses during core operation were performed with CASMO-4 (using the 70-group cross-section library), a two-dimensional multigroup transport theory code based on capture probabilities [4.7-4.9]. CASMO-4 is used to determine the isotopic composition of the spent fuel.
In addition, the CASMO-4 calculations are restarted in the storage rack geometry, yielding the two-dimensional infinite multiplication factor (kinf) for the storage rack to determine the reactivity effect of fuel and rack tolerances, temperature variation, depletion uncertainty, and to perform various studies. For all calculations in the spent fuel pool racks, the Xe-135 concentration in the fuel is conservatively set to zero.
The evaluation performed to establish the burnup versus enrichment curve (loading curve) for the Region 1 and Region 2 racks, consists of MCNP4a calculations performed at selected enrichments between 2.0 wt% and 5.0 wt%, and for burnup values slightly above and below the expected loading curve. Points on the proposed loading curve are then calculated by linear interpolation for each enrichment, based on an appropriate target value (max kff = 0.9950) for the reactivity. Bumup versus enrichment values are calculated for cooling times of 0, 5, 10, 15 and 20 years. For the Region 3 racks the minimum required burnup for the single spent fuel assembly 235U and at was determined with MCNP4a calculations, performed at an enrichment of 5.0 wt%
burnup values slightly above and below the expected required bumup. The minimum burnup was then calculated by linear interpolation, based on an appropriate target value (max kff
= 0.9958) for the reactivity.
The maximum klff is determined from the MCNP4a calculated klff, the calculational bias, the temperature bias, and the applicable uncertainties and tolerances (bias uncertainty, calculational uncertainty, rack tolerances, fuel tolerances, depletion uncertainty) using the following formula:
Holtec Report HI-2022867 4-4 Holtec Project 1196
Max k*' 1 = Calculated kff + biases + [Y, (Uncertaintyi) 2]1/2 In the geometric models used for the calculations, each fuel rod and its cladding were described explicitly and reflecting or periodic boundary conditions were used in the radial direction which has the effect of creating an infinite radial array of storage cells, except for the assessment of certain abnormal/accident conditions in which neutron leakage is inherent.
4.3 ACCEPTANCE CRITERIA The high-density spent fuel PWR storage racks for ANO are analyzed in accordance with the applicable codes and standards listed below. The objective of this analysis is to ensure that the effective neutron multiplication factor (keff) is less than or equal to 0.95 with the storage racks fully loaded with fuel of the highest permissible reactivity and the pool flooded with borated water at a temperature corresponding to the highest reactivity. In addition, it is demonstrated that keff is less than 1.0 under the assumed loss of soluble boron in the pool water, i.e. assuming unborated water in the spent fuel pool. The maximum calculated reactivities include a margin for uncertainty in reactivity calculations, including manufacturing tolerances, and are calculated with a 95% probability at a 95% confidence level [4. 1].
Applicable codes, standard, and regulations or pertinent sections thereof, include the following:
- Code of FederalRegulations, Title 10, Part 50, Appendix A, General Design Criterion 62, "Prevention of Criticality in Fuel Storage and Handling."
- USNRC Standard Review Plan, NUREG-0800, Section 9.1.2, Spent Fuel Storage, Rev. 3
- July 1981.
- USNRC letter of April 14, 1978, to all Power Reactor Licensees - OT Position for Review and Acceptance of Spent Fuel Storage and Handling Applications, including modification letter dated January 18, 1979.
- L. Kopp, "Guidance on the Regulatory Requirements for Criticality Analysis of Fuel Storage at Light-Water Reactor Power Plants," NRC Memorandum from L. Kopp to T.
Collins, August 19, 1998.
- USNRC Regulatory Guide 1.13, Spent Fuel Storage Facility Design Basis, Rev. 2 (proposed), December 1981.
I The maximum klff value listed in Table 4.7.1 through Table 4.7.12 may differ from the calculated value based on this formula (Ak = 0.0001) due to rounding.
4-5 Holtec Project 1196 Report HI-2022867 Holtec Report Holtec HI-2022867 4-5 Holtec Project 1196
- ANSI ANS-8.17-1984, Criticality Safety Criteria for the Handling, Storage and Transportation of LWR Fuel Outside Reactors.
- Code of Federal Regulation 10CFR50.68, Criticality Accident Requirements (for soluble boron).
4.4 ASSUMPTIONS To assure the true reactivity will always be less than the calculated reactivity, the following conservative design criteria and assumptions were employed:
- 1) Moderator is borated or unborated water at a temperature in the operating range that results in the highest reactivity, as determined by the analysis.
- 2) Neutron absorption in minor structural members is neglected, i.e., spacer grids are replaced by water.
- 3) The effective multiplication factor of an infinite radial array of fuel assemblies was used in the analyses, except for the assessment of certain abnormal/accident conditions in which neutron leakage is inherent.
- 4) The B4 C loading in the neutron absorber panels is nominally 25 wt%, with an uncertainty of
+/- 0.5 wt%
- 5) Axial Power Shaping Rods (APSRs) and Burnable Poison Rod Assemblies (BPRAs) are assumed to cover the entire active fuel length of the assembly during depletion. No credit is taken in the rack criticality calculations for the APSRs and BPRAs.
4.5 INPUT DATA 4.5.1 Fuel Assembly Specification The spent fuel storage racks are designed to accommodate B&W 15x15 fuel assemblies (HTP[ 2' and NON-HTP). The design specifications for these fuel assemblies, which were used for this analysis, are given in Table 4.5.1.
[21 HTP - High Thermal Performance 867 4-6 Holtec Project 1196 Report HI-2022 Holtec Report HI-2022867 4-6 Holtec Project 1196
4.5.2 Core OperatingParameters Core operating parameters are necessary for fuel depletion calculations performed with CASMO-4. The core parameters necessary for the depletion calculations are presented in Table 4.5.2. Temperature and soluble boron values are taken as the upper bound (most conservative) of the core operating parameters of ANO Unit 1. The neutron spectrum is hardened by each of these parameters, leading to a greater production of plutonium during depletion, which results in conservative reactivity values.
4.5.3 Axial Burnup Distribution Axial burnup profiles were provided by Entergy and are documented in Table 4.5.3 for low burnup assemblies (<25 GWD/MTU). For assemblies with burnup greater than or equal to 25 GWD/MTU, the axial burnup distribution from [4.12] was specified and is also provided in Table 4.5.3 under the Holtec column. This distribution has been used and approved in previous wet storage rack submittals to the NRC (Docket W's: 50-368, ANO Unit 2; 50-395, V.C.
Summer; 50-275/50-323, Diablo Canyon).
4.5.4 Core Inserts There is the potential for an insert (BPRA or APSR or both, but not simultaneously) to be located in the assembly during different exposure intervals in the assembly's core lifetime. The design specifications for the BPRAs and APSRs are given in Tables 4.5.4 through 4.5.6. The core inserts are conservatively considered only in the depletion calculations; no credit is taken for core inserts in the rack criticality calculations.
4.5.5 ANO Unit I Storage Rack Specification The storage cell characteristics for the Region 1, 2 & 3 storage racks which are used in the criticality evaluations are summarized in Table 4.5.7 through Table 4.5.9.
4.5.5.1 Region 1 Style Storage Racks The Region 1 storage cells are composed of stainless steel boxes separated by a gap with Boraflex neutron absorber panels, (attached by stainless steel sheathing) centered on each side of the storage cell. The steel walls define the storage cells and the stainless steel sheathing supports the Boraflex neutron absorber panel and defines the boundary of the flux-trap water-gap used to augment reactivity control. The Boraflex is conservatively assumed to be completely degraded Holtec Report HI-2022867 4-7 Holtec Project 1196
and replaced with water. Stainless steel channels connect the storage cells in a rigid structure and define the flux-trap between the sheathing of the neutron absorber panels. Figure 4.5.9 provides a sketch of the Region 1 racks along with the critical dimensions. Additionally, the Region 1 racks contain sheathing on the side of the racks that faces another rack, however there is no sheathing on the side of the racks that faces the spent fuel pool wall.
The calculational models consist of either a single storage cell or a group of 25 storage cells (5x5) with reflecting boundary conditions or a group of four storage cells (2x2) with periodic boundary conditions through the centerline of the water gap on the outer boundary of the four cells, thus simulating an infinite array of Region 1 storage cells. Figure 4.5.1 and Figure 4.5.2 show the actual MCNP4a calculational model of the nominal Region 1 spent fuel storage cell, as drawn by the two-dimensional plotter in MCNP4a for the individual cell model and the 2x2 model, respectively.
4.5.5.2 Region 2 Style Storage Racks The Region 2 storage cells are composed of stainless steel walls with no neutron absorber panels.
The stainless steel walls are formed in such a way as to create a water gap between adjacent cells. Figure 4.5.10 provides a sketch of the Region 2 racks along with the critical dimensions.
The calculational models consist of either a single storage cell or a group of 25 storage cells (5x5) with reflecting boundary conditions or a group of four storage cells (2x2) with periodic boundary conditions through the centerline of the water gap on the outer boundary of the four cells, thus simulating an infinite array of Region 2 storage cells. Figure 4.5.3 and Figure 4.5.4 shows the actual MCNP4a calculational model of the nominal Region 2 spent fuel storage cell, as drawn by the two-dimensional plotter in MCNP4a for the individual cell model and the 2x2 model, respectively.
4.5.5.3 Region 3 Style Storage Racks The Region 3 storage cells are identical to the Region 2 storage cells, with the single exception of a metamic insert centrally located in the water gap between storage cells. Figure 4.5.11 provides a sketch of the Region 3 racks along with the critical dimensions.
The calculational models consist of either a single storage cell or a group of 25 storage cells (5x5) with reflecting boundary conditions or a group of four storage cells (2x2) with periodic boundary conditions through the centerline of the water gap on the outer boundary of the four cells, thus simulating an infinite array of Region 3 storage cells. Figure 4.5.5 and Figure 4.5.6 shows the actual MCNP4a calculational model of the nominal Region 3 spent fuel storage cell, as drawn by the two-dimensional plotter in MCNP4a for the individual cell model and the 2x2 model, respectively.
HI-2022867 4-8 Holtec Project 1196 Report HI-2022867 Holtec Report 4-8 Holtec Project 1196
4.5.5.4 Gaps Between Adjacent Racks In addition to the calculations for each style of rack in the ANO Unit 1 spent fuel pool, the reactivity effect of potential interaction between adjacent racks and between different loading patterns is addressed. Figure 4.5.7 shows a diagram of the spent fuel pool layout, including location of the different styles of racks, with respect to each other, and the distances of the gaps between adjacent racks. The values taken from this figure are the minimum distances from the center of one storage cell to the center of the storage cell in the adjacent rack, denoted by a "C" and followed by the dimension in inches. Table 4.5.10 identifies the possible rack-to-rack interactions, the centerline-to-centerline distance, and the calculated gap between the adjacent racks. Figure 4.5.8 presents a diagram as to how the distance between racks listed in Table 4.5.10 is measured.
4.6 COMPUTER CODES The following computer codes were used during this analysis.
- MCNP4a [4.3] is a three-dimensional continuous energy Monte Carlo code developed at Los Alamos National Laboratory. This code offers the capability of performing full three-dimensional calculations for the loaded storage racks. MCNP4a was run on the PCs at Holtec.
- CASMO-4, Version 2.05.14 [4.7-4.9] is a two-dimensional multigroup transport theory code developed by Studsvik of Sweden. CASMO-4 performs cell criticality calculations and burnup. CASMO-4 has the capability of analytically restarting burned fuel assemblies in the rack configuration. This code was used to determine the reactivity effects of tolerances and fuel depletion. The CASMO-4 code was run on a PC at Holtec.
4.7 ANALYSIS This section describes the calculations that were used to determine the acceptable storage criteria for the Region 1, Region 2 and Region 3 style racks. In addition, this section discusses the possible abnormal and accident conditions.
Unless otherwise stated, all calculations assumed nominal characteristics for the fuel and the fuel storage cells. The effect of the manufacturing tolerances is accounted for with a reactivity adjustment as discussed below.
As discussed in Section 4.2, MCNP4a was the primary code used in the PWR calculations.
CASMO-4 was used to determine the reactivity effect of tolerances and for depletion calculations. MCNP4a was used for reference cases and to perform calculations which are not possible with CASMO-4 (e.g. eccentric fuel positioning, axial burnup distributions, and fuel misloading).
Holtec Report HI-2022867 4-9 Holtec Project 1196
Figures 4.5.1 through 4.5.6 are pictures of the basic calculational models used in MCNP4a.
These pictures were created with the two-dimensional plotter in MCNP4a and clearly indicate the explicit modeling of fuel rods in each fuel assembly. In CASMO-4, a single cell is modeled, and since CASMO-4 is a two-dimensional code, the fuel assembly hardware above and below the active fuel length is not represented. The three-dimensional MCNP4a models that included axial leakage assumed approximately 30 cm of water above and below the active fuel length.
Additional models with more than four cells were generated with MCNP4a to investigate the effect of accident conditions. These models are discussed in the appropriate section.
4.7.1 CalculationalMethodologies Applicable to Region 1, Region 2 & Region 3 4.7.1.1 Moderator Temperature Effect For the depletion calculations, the temperature at the top of the active region is used as the moderator temperature (see Table 4.5.2). However, the reactivity in the rack is dominated by the area slightly below the top of the active region, where the moderator temperature in the core is lower. Since the reactivity increases significantly with increasing moderator temperature, the assumption used in the depletion calculations is conservative.
4.7.1.2 Reactivity Effect of Inserts During Depletion Due to variations in plant operation, it is impossible to predict the exact exposure intervals that BPRAs and APSRs will be in the assemblies during core operation. Therefore, for conservatism, BPRAs are assumed to be present early in the assembly's life, when the BPRA has a stronger reactivity effect than the APSR. APSRs are then assumed to be inserted into the assembly once the BPRA has received a high enough bumup for their reactivity effect to be less than that of the APSRs, typically around 15 GWD/MTU.
To determine the burnup at which to change from a BPRA to an APSR, termed here as the "crossover burnup", depletion calculations are performed in CASMO-4 with the HTP assembly containing an APSR, a BPRA or no insert. The assembly and the insert, if the assembly has one, is then transferred into the Region 1 rack. The calculated reactivities as a function of bumup are compared between the three assemblies (with APSR, with BPRA and with no insert) and the bumup at which the reactivity of the assembly with the BPRA is equal to the reactivity of the assembly with the APSR is calculated. Calculations to determine the reactivity of the assembly with an APSR or BPRA were performed for enrichments between 2.0 and 5.0 wto 235 U in 0.5 wt% increments and for cooling times between 0 and 20 years. Table 4.7.16 presents an example of the reactivity effect of the presence of fuel inserts (BPRA, APSR and no insert) for an enrichment of 5.0 wt% 235U and a cooling time of 0 years. From the calculations it was determined that the crossover burnup is dependent upon enrichment, but shows only little variation with cooling time. Therefore, the crossover bumup for each enrichment is calculated Holtec Report HI-2022867 4-10 Holtec Project 1196
by averaging the crossover bumup for each enrichment at cooling times of 0, 5, 10, 15 and 20 years. The enrichment dependency of the crossover burnup is shown in Table 4.7.13. These values are used in all subsequent depletion calculations.
4.7.1.3 Reactivity Effect of Axial Burnup Distribution Initially, fuel loaded into the reactor will burn with a slightly skewed cosine power distribution.
As burnup progresses, the burnup distribution will tend to flatten, becoming more highly burned in the central regions than in the upper and lower ends. At high burnup, the more reactive fuel near the ends of the fuel assembly (less than average burnup) occurs in regions of lower reactivity worth due to neutron leakage. Consequently, it would be expected that over most of the burnup history, distributed burnup fuel assemblies would exhibit a slightly lower reactivity than that calculated for the average bumup. As burnup progresses, the distribution, to some extent, tends to be self-regulating as controlled by the axial power distribution, precluding the existence of large regions of significantly reduced burnup.
Generic analytic results of the axial burnup effect for assemblies without axial blankets have been provided by Turner [4.12] based upon calculated and measured axial bumup distributions.
These analyses confirm the minor and generally negative reactivity effect of the axially distributed burnup compared to a flat distribution, becoming positive at burnups greater than about 30 GWD/MTU. The trends observed in [4.12] suggest the possibility of a small positive reactivity effect above 30 GWD/MTU increasing to slightly over 1% Ak at 40 GWD/MTU. The required burnup for the maximum enrichment is slightly higher than 30 GWD/MTU. Therefore, a positive reactivity effect of the axially distributed burnup is possible. Calculations are performed with the HTP axial burnup distribution from Table 4.5.3 for bumups at or below 25 GWD/MTU and with the Holtec axial burnup distribution for burnups above 25 GWD/MTU.
As Section 4.5.3 discusses, the Holtec axial burnup distribution is specified to be used for bumups at 25 GWD/MTU. However, use of the HTP axial burnup distribution specified in Table 4.5.3 at 25 GWD/MTU is conservative, due to the significantly lower relative burnups near the ends of the active fuel region.
4.7.1.4 Isotopic Compositions To perform the criticality evaluation for spent fuel in MCNP4a, the isotopic composition of the fuel is calculated with the depletion code CASMO-4 and then specified as input data in the MCNP4a run. The CASMO-4 calculations to obtain the isotopic compositions for MCNP4a were performed generically, with one calculation for each enrichment, and bumups in increments of 2.5 GWD/MTU or less. The isotopic composition for any given bumup is then determined by linear interpolation.
Holtec Report HI-2022867 4-11 Holtec Project 1196
4.7.1.5 Uncertainty in Depletion Calculations Since critical experiment data with spent fuel is not available for determining the uncertainty in burnup-dependent reactivity calculations, an allowance for uncertainty in reactivity was assigned based upon other considerations. Assuming the uncertainty in depletion calculations is less than 5% of the total reactivity decrement, a burnup dependent uncertainty in reactivity for burnup calculations may be assigned [4.10]. This allowance is statistically combined with the other reactivity allowances in the determination of the maximum kff for normal conditions where assembly burnup is credited.
4.7.2 Region I The purpose of the criticality calculations for the Region 1 style racks is to qualify the racks for storage of spent fuel assemblies with design specifications as shown in Table 4.5.1 and a maximum nominal initial enrichment of 5.0 wt% 235U that have accumulated a minimum bumup with credit for cooling times between 0 and 20 years. The purpose of the criticality calculations is to determine the initial enrichment and burnup combinations required for the storage of spent fuel assemblies with nominal initial enrichments up to 5.0 wt% 2351U and for cooling times up to 20 years. Additionally, the Region 1 racks are qualified for storage of fresh fuel assemblies, in a checkerboard pattern with empty storage cells, at a maximum nominal enrichment of 5.0 wt0 /o 2 3 5U.
4.7.2.1 Identification of Reference Fuel Assembly CASMO-4 calculations were performed to determine which of the two assemblies in Table 4.5.1 is bounding in the Region 1 racks. In the calculations, the fuel assembly is burned in the core configuration and restarted in the rack configuration. Three different scenarios were analyzed:
empty guide tubes in the core, BPRAs in the guide tubes in the core, and APSRs in the guide tubes in the core. In all scenarios, the insert was removed when the assembly was modeled in the rack. The HTP assembly was determined to have the highest reactivity for all burnup and enrichment combinations. This assembly type is therefore used in all subsequent calculations.
4.7.2.2 Eccentric Fuel Assembly Positioning The fuel assembly is assumed to be normally located in the center of the storage rack cell. In the absence of a fixed neutron absorber, the eccentric location of fuel assemblies in the storage cells may produce a positive reactivity effect. Therefore, MCNP4a calculations for a uniform loading of spent fuel assemblies and a checkerboard of fresh fuel assemblies and empty storage locations were performed with the fuel assemblies assumed to be in the comer of the storage rack cell (four-assembly cluster at closest approach). Three different enrichment and bumup combinations were analyzed for the spent fuel configuration. These calculations indicate that eccentric fuel positioning results in an increase in reactivity.
Holtec Report HI-2022867 4-12 Holtec Project 1196
The eccentric positioning is performed in a very conservative manner, assuming 4 assemblies in the comers of the storage cell, at closest approach to each other, and that these clusters of four assemblies are repeated throughout the rack. However, since eccentric positioning is highly unlikely to occur in this manner and recognizing that placement of fuel assemblies in the storage cells is random, the maximum reactivity effect of eccentric positioning for both spent and fresh fuel is applied as an uncertainty, and combined statistically with other uncertainties as shown in Table 4.7.1 through Table 4.7.4.
4.7.2.3 Uncertainties Due to Manufacturing Tolerances In the calculation of the final kcff, the effect of manufacturing tolerances on reactivity must be included. CASMO-4 was used to perform these calculations. As allowed in [4.10], the methodology employed to calculate the tolerance effects combine both the worst-case bounding value and sensitivity study approaches. The evaluations include tolerances of the rack dimensions (see Table 4.5.7) and tolerances of the fuel dimensions (see Table 4.5.1). As for the bounding assembly, calculations are performed for different enrichments and bumups. The reference condition is the condition with nominal dimensions and properties. To determine the Ak associated with a specific manufacturing tolerance, the kinf calculated for the reference condition is compared to the kinf from a calculation with the tolerance included. Note that for the individual parameters associated with a tolerance, no statistical approach is utilized. Instead, the full tolerance value is utilized to determine the maximum reactivity effect. All of the Ak values from the various tolerances are statistically combined (square root of the sum of the squares) to determine the final reactivity allowance for manufacturing tolerances. Only the Ak values in the positive direction (increasing reactivity) were used in the statistical combination. The fuel and rack tolerances included in this analysis are described below:
Fuel Tolerances
- Increased Fuel Density 0.20g/cm 3 23 5
- Increased Fuel Enrichment 0.05 wt% U
- Fuel Rod Pitch +0.00258 in./-0.00387 in.
- Fuel Rod Cladding Outside Diameter +/- 0.002 in.
- Fuel Rod Cladding Inner Diameter +/- 0.002 in.
- Fuel Pellet Outside Diameter
- 0.0005 in.
- Guide Tube Outside Diameter +/- 0.002 in.
- Guide Tube Inside Diameter +/- 0.0052 in.
Rack Tolerances
- Variable Cell Inner Dimension & Constant Water Gap +0.025 in./-0.05 in.
4-13 Holtec Project 1196 Holtec Report HI-2022867 Holtec Report HI-2022867 4-13 Holtec Project 1196
" Variable Water Gap & Constant Pitch +0.05 in./-0.025 in.[31
" Box Wall Thickness +/- 0.004 in.
- Sheathing Thickness +/- 0.004 in.
" Poison Gap Thickness +/- 0.010 in.
The reactivity effects of the fuel and rack tolerances shown above were calculated for enrichments between 2.0 and 5.0 wt% 235U and for 0 cooling time. For longer cooling times the fuel and rack tolerances from 0 cooling time are used. Table 4.7.17 provides representative examples of the reactivity effect of the fuel and rack tolerances for the Region 1 racks.
4.7.2.4 Temperature and Water Density Effects Pool water temperature effects on reactivity in the Region 1 racks have been calculated with CASMO-4 for enrichments from 2.0 to 5.0 wt/o 213U and cooling times from 0 years to 20 years.
The results in Table 4.7.18 for 5.0 wt 0 235U show that the spent fuel pool temperature coefficient of reactivity is positive, i.e. a higher temperature results in a higher reactivity.
Consequently, all CASMO-4 calculations are evaluated at 150 *F. Temperatures higher than 150
'F are treated as accidents and discussed in Section 4.7.5.
In MCNP4a, the Doppler treatment and cross-sections are valid only at 300K (27 °C). Therefore, a Ak is determined in CASMO-4 from 27 *C (80.33 *F) to 150 *F, and is included in the final klff calculation as a bias. The temperature bias is shown on Table 4.7.1 through Table 4.7.4.
4.7.2.5 Calculation of Maximum keff Using the calculational model shown in Figure 4.5.1 and 4.5.2 and the reference HTP 15x15 fuel assembly, the kerr in the Region 1 storage racks has been calculated with MCNP4a. A summary of the calculation of the maximum kelf, which is based on the formula in Section 4.2, for spent fuel of maximum nominal initial enrichment of 5 wt 0 235U and for the fresh fuel checkerboard is shown in Table 4.7.1 and Table 4.7.3 without soluble boron. Uncertainties associated with depletion are not applicable to the Region 1 checkerboard of fresh fuel assemblies and empty storage cells. Results show that the maximum krff of the Region 1 racks is less than 1.0 at a 95%
probability at a 95% confidence level with no credit for soluble boron.
[31 No tolerance was given for the water gap, therefore it was assumed that the water gap tolerance is consistent with the tolerance for the storage cell inner dimension.
4-14 Holtec Project 1196 Holtec Report HI-2022867 HI-2022867 4-14 Holtec Project 1196
4.7.2.6 Determination of Burnup Versus Enrichment Values To establish a burnup versus enrichment curve (loading curve), calculations were performed at selected enrichments between 2.0 wt% and 5.0 wt%, and for burnup values slightly above and below the expected loading curve. Points on the proposed loading curve are then calculated by linear interpolation for each enrichment, based on an appropriate target value (max klf = 0.9950) for the reactivity. Bumup versus enrichment values are calculated for cooling times of 0, 5, 10, 15 and 20 years and presented in Table 4.7.14.
4.7.2.7 Soluble Boron Concentration for Maximum ke. of 0.95 Calculations crediting soluble boron in the spent fuel pool to ensure that the reactivity does not exceed 0.95 are also performed. Calculations for a uniform loading of spent fuel are performed for enrichment and cooling time combinations of 2.0 wto 235U at 0 years cooling, 5.0 wto0 23 U at 0 years cooling and 5.0 wt%/ 235U at 20 years cooling at a soluble boron level of 0 ppm and 400 ppm. For a checkerboard of fresh fuel and empty cells, calculations are performed at 5.0 wt% 235U and with a soluble boron level of 0 ppm and 400 ppm. The minimum soluble boron requirement is determined by linear interpolation between soluble boron levels to achieve a target maximum klfr of 0.9450. In all cases, the maximum leff including all applicable biases and uncertainties is below the regulatory limit of 0.95. The results for 5.0 wt% initial enrichment are also listed in Table 4.7.2 and Table 4.7.4 for uniform loading of spent fuel and a checkerboard of fresh fuel assemblies and empty storage cells, respectively.
4.7.3 Region 2 The purpose of the criticality calculations for the PWR Region 2 style racks is to qualify the racks for storage of fuel assemblies with design specifications as shown in Table 4.5.1 and a maximum nominal initial enrichment of 5.0 wt% 230U that have accumulated a minimum burnup with credit for cooling times between 0 and 20 years. The purpose of the criticality calculations is to determine the initial enrichment and burnup combinations required for the storage of fuel assemblies with nominal initial enrichments up to 5.0 wt 0 235U and for cooling times up to 20 years. Additionally, the Region 2 racks are qualified for storage of fresh fuel assemblies, in a checkerboard pattern with empty storage cells, at a maximum nominal enrichment of 5.0 wt 0 Z5 U.
4.7.3.1 Identification of Reference Fuel Assembly CASMO-4 calculations were performed to determine which of the two assemblies in Table 4.5.1 is bounding in the Region 2 racks. In the calculations, the fuel assembly is burned in the core configuration and restarted in the rack configuration. Three different scenarios were analyzed:
empty guide tubes in the core, BPRAs in the guide tubes in the core, and APSRs in the guide Holtec Report HI-2022867 4-15 Holtec Project 1196
tubes in the core. In all scenarios, the insert was removed when the assembly was modeled in the rack. The HTP assembly was determined to have the highest reactivity for all burnup and enrichment combinations. This assembly type is therefore used in all subsequent calculations.
4.7.3.2 Eccentric Fuel Assembly Positioning The fuel assembly is assumed to be normally located in the center of the storage rack cell. In the absence of a fixed neutron absorber, the eccentric location of fuel assemblies in the storage cells may produce a positive reactivity effect. Therefore, MCNP4a calculations for a uniform loading of spent fuel assemblies and a checkerboard of fresh fuel assemblies and empty storage locations were performed with the fuel assemblies assumed to be in the comer of the storage rack cell (four-assembly cluster at closest approach). Three different enrichment and bumup combinations were analyzed for the spent fuel configuration. These calculations indicate that eccentric fuel positioning results in an increase in reactivity.
The eccentric positioning is performed in a very conservative manner, assuming 4 assemblies in the comers of the storage cell, at closest approach to each other, and that these clusters of four assemblies are repeated throughout the rack. However, since eccentric positioning is highly unlikely to occur in this manner and recognizing that placement of fuel assemblies in the storage cells is random, the maximum reactivity effect of eccentric positioning for both spent and fresh fuel is applied as an uncertainty, and combined statistically with other uncertainties as shown in Table 4.7.5 through Table 4.7.8.
4.7.3.3 Uncertainties Due to Manufacturing Tolerances In the calculation of the final kff, the effect of manufacturing tolerances on reactivity must be included. CASMO-4 was used to perform these calculations. As allowed in [4.10], the methodology employed to calculate the tolerance effects combine both the worst-case bounding value and sensitivity study approaches. The evaluations include tolerances of the rack dimensions (see Table 4.5.8) and tolerances of the fuel dimensions (see Table 4.5.1). As for the bounding assembly, calculations are performed for different enrichments and bumups. The reference condition is the condition with nominal dimensions and properties. To determine the Ak associated with a specific manufacturing tolerance, the kf calculated for the reference condition is compared to the kif from a calculation with the tolerance included. Note that for the individual parameters associated with a tolerance, no statistical approach is utilized. Instead, the full tolerance value is utilized to determine the maximum reactivity effect. All of the Ak values from the various tolerances are statistically combined (square root of the sum of the squares) to determine the final reactivity allowance for manufacturing tolerances. Only the Ak values in the positive direction (increasing reactivity) were used in the statistical combination. The fuel and rack tolerances included in this analysis are described below:
4-16 Holtec Project 1196 Holtec Report HI-2022867 Holtec HI-2022867 4-16 Holtec Project 1196
Fuel Tolerances 3
" Increased Fuel Density 0.20g/cm
" Increased Fuel Enrichment 0.05 wt0 /o 235 U
- Fuel Rod Pitch +0.00258 in./-0.00387 in.
" Fuel Rod Cladding Outside Diameter
- 0.002 in.
" Fuel Rod Cladding Inner Diameter
- 0.002 in.
" Fuel Pellet Outside Diameter
- 0.0005 in.
" Guide Tube Outside Diameter
- 0.002 in.
- Guide Tube Inside Diameter
- 0.0052 in.
Rack Tolerances
" Variable Cell Inner Dimension & Constant Water Gap +0.05 in./-0.025 in.
- Variable Water Gap & Constant Pitch +0.166 in./-0.221 in.
" Box Wall Thickness +/- 0.004 in.
The reactivity effect of the fuel and rack tolerances shown above were calculated for enrichments between 2.0 and 5.0 wt% 235U and for 0 cooling time. For longer cooling times the fuel and rack tolerances from 0 cooling time are used. Table 4.7.19 provides representative examples of the reactivity effect of the fuel and rack tolerances for the Region 2 racks.
4.7.3.4 Temperature and Water Density Effects Pool water temperature effects on reactivity in the Region 2 racks have been calculated with CASMO-4 for enrichments from 2.0 to 5.0 wt%/o 235U and cooling times from 0 to 20 years. The results in Table 4.7.20 for 5.0 wt% 235U show that the spent fuel pool temperature coefficient of reactivity is positive, i.e. a higher temperature results in a higher reactivity. Consequently, all CASMO-4 calculations are evaluated at 150 'F. Temperatures higher than 150 °F are treated as accidents and discussed in Section 4.7.5.
In MCNP4a, the Doppler treatment and cross-sections are valid only at 300K (27 'C). Therefore, a Ak is determined in CASMO-4 from 27 °C (80.33 'F) to 150 °F, and is included in the final krff calculation as a bias. The temperature bias is shown on Table 4.7.5 through Table 4.7.8.
4.7.3.5 Calculation of Maximum keff Using the calculational model shown in Figure 4.5.3 and 4.5.4 and the reference HTP 15x15 fuel assembly, the keff in the Region 2 storage racks has been calculated with MCNP4a. Summary of the calculation of the maximum kerr, which is based on the formula in Section 4.2, for spent fuel of maximum nominal enrichment of 5.0 wt% 235U and for the fresh fuel checkerboard are shown in Table 4.7.5 and Table 4.7.7 without soluble boron. Uncertainties associated with depletion are not applicable to the Region 2 checkerboard of fresh fuel assemblies and empty storage cells.
Results show that the maximum keff of the Region 2 racks is less than 1.0 at a 95% probability at a 95% confidence level with no credit for soluble boron.
Holtec Report HI-2022867 4-17 Holtec Project 1196
4.7.3.6 Determination of Burnup Versus Enrichment Values To establish a burnup versus enrichment curve (loading curve), calculations were performed at selected enrichments between 2.0 wt% and 5.0 wt%/o, and for burnup values slightly above and below the expected loading curve. Points on the proposed loading curve are then calculated by linear interpolation for each enrichment, based on an appropriate target value (max kff = 0.9950) for the reactivity. Burnup versus enrichment values are calculated for cooling times of 0, 5, 10, 15 and 20 years and presented in Table 4.7.15.
4.7.3.7 Soluble Boron Concentration for Maximum keff of 0.95 The calculations crediting soluble boron in the spent fuel pool to ensure that the reactivity does not exceed 0.95 are also performed. Calculations for a uniform loading of spent fuel are performed for enrichment and cooling time combinations of 2.0 wto 235U at 0 years cooling, 5.0 wt% 235U at 0 years cooling and 5.0 wt%/ 235U at 20 years cooling at a soluble boron level of 0 ppm and 400 ppm. For a checkerboard of fresh fuel and empty storage cells, calculations are performed at 5.0 wt 0 235U and with a soluble boron concentration of 0 ppm and 400 ppm. The minimum soluble boron requirement is determined by linear interpolation between soluble boron levels to achieve a target maximum kff of 0.9450. In all cases, the maximum keff including all applicable biases and uncertainties is below the regulatory limit of 0.95. The results for 5.0 wt%
initial enrichment is also listed in Table 4.7.6 and Table 4.7.8 for uniform loading of spent fuel and a checkerboard of fresh fuel assemblies and empty storage cells, respectively.
4.7.4 Region 3 The purpose of the criticality calculations for the PWR Region 3 style racks is to qualify the racks for storage of new unburned fuel assemblies with design specifications as shown in Table 4.5.1 and a maximum nominal enrichment of 4.35 wt 0 235U. Additionally, the Region 3 style racks are qualified for storage of a "3 of 4" configuration of 3 fresh fuel assemblies with a maximum nominal enrichment of 5.0 wt%/o 235U and 1 spent fuel assembly with a maximum nominal initial enrichment of 5.0 wt% 235U that have accumulated a minimum burnup of 20.1 GWD/MTU with 0 years cooling time. No credit was taken in the "3 of 4" configuration for longer cooling times, as this would provide only a small reduction in the required burnup for the single spent fuel assembly in this configuration.
4.7.4.1 Identification of Reference Fuel Assembly CASMO-4 calculations were performed to determine which of the two assemblies in Table 4.5.1 is bounding in the Region 3 racks. In the calculations, the fuel assembly is burned in the core configuration and restarted in the rack configuration. Three different scenarios were analyzed:
empty guide tubes in the core, BPRAs in the guide tubes in the core, and APSRs in the guide Holtec Report HI-2022867 4-18 Hottec Project 1196
tubes in the core. In all scenarios, the insert was removed when the assembly was modeled in the rack. The HTP assembly was determined to have the highest reactivity for all burnup and enrichment combinations. This assembly type is therefore used in all subsequent calculations.
4.7.4.2 Eccentric Fuel Assembly Positioning The fuel assembly is assumed to be normally located in the center of the storage rack cell.
Nevertheless, MCNP4a calculations were made with the fuel assemblies assumed to be in the comer of the storage rack cell (four-assembly cluster at closest approach). These calculations indicate that eccentric fuel positioning results in a decrease in reactivity. The highest reactivity, therefore, corresponds to the reference design with the fuel assemblies positioned in the center of the storage cells.
4.7.4.3 Uncertainties Due to Manufacturing Tolerances In the calculation of the final ktT, the effect of manufacturing tolerances on reactivity must be included. CASMO-4 was used to perform these calculations. As allowed in [4.10], the methodology employed to calculate the tolerance effects combine both the worst-case bounding value and sensitivity study approaches. The evaluations include tolerances of the rack dimensions (see Table 4.5.9) and tolerances of the fuel dimensions (see Table 4.5.1).
The reference fuel assembly with an initial nominal enrichment of 4.35 wt0 235U and 5.0 wt%/o 235U was used for these studies in the fresh fuel configuration and the "3 of 4" configuration, respectively. The reference condition is the condition with nominal dimensions and properties.
To determine the Ak associated with a specific manufacturing tolerance, the reference kinf was compared to the kinf from a calculation with the tolerance included. Note that for the individual parameters associated with a tolerance, no statistical approach is utilized. Instead, the full tolerance value is utilized to determine the maximum reactivity effect. All of the Ak values from the various tolerances are statistically combined (square root of the sum of the squares) to determine the final reactivity allowance for manufacturing tolerances. Only the Ak values in the positive direction (increasing reactivity) were used in the statistical combination. The fuel and rack tolerances included in this analysis are described below:
Fuel Tolerances
" Increased Fuel Density 0.20g/cm 3
- Increased Fuel Enrichment 0.05 wt0 235U
" Fuel Rod Pitch +0.00258 in./-0.00387 in.
- Fuel Rod Cladding Outside Diameter 1 0.002 in.
" Fuel Rod Cladding Inner Diameter +/- 0.002 in.
- Fuel Pellet Outside Diameter +/- 0.0005 in.
- Guide Tube Outside Diameter 1 0.002 in.
- Guide Tube Inside Diameter +/- 0.0052 in.
Holtec Report HI-2022867 4-19 Holtec Project 1196
Rack Tolerances
" Cell Inner Dimension & Pitch +0.05 in./-0.025 in.
- Cell Inner Dimension & Water Gap +0.166 in./-0.221 in.141
" Box Wall Thickness
- 0.004 in.
" Insert Sheathing Thickness
- 0.003 in.
" Insert Water Gap
- 0.05 in.
" Metamic Thickness d: 0.003 in.
- Metamic Width +/- 0.062 in.
" Metamic B4 C Weight Percent 0.5 wt%/o The reactivity effect of the fuel and rack tolerances shown above were calculated for enrichments of 4.35 wt% 235U and 5.0 wt 0 235U and for 0 cooling time. Table 4.7.21 provides representative examples of the reactivity effect of the fuel and rack tolerances for the Region 3 racks.
4.7.4.4 Temperature and Water Density Effects Pool water temperature effects on reactivity in the Region 3 racks have been calculated with CASMO-4 for enrichments of 4.35 and 5.0 wt% 235U. The results in Table 4.7.22 for 4.35 wt%/o 235U and 5.0 wt% 235U show that the spent fuel pool temperature coefficient of reactivity is negative, i.e. a lower temperature results in a higher reactivity. Consequently, all CASMO-4 calculations are evaluated at 4 °C, which corresponds to the highest density of water.
In MCNP4a, the Doppler treatment and cross-sections are valid only at 300K (27 °C). Therefore, a Ak is determined in CASMO-4 from 27 °C to 4 *C, and is included in the final keff calculation as a bias. The temperature bias is shown on Table 4.7.9 though Table 4.7.12.
4.7.4.5 Calculation of Maximum kef Using the calculational model shown in Figure 4.5.5 and Figure 4.5.6 and the reference HTP 15x15 fuel assembly, the klf in the Region 3 storage racks has been calculated with MCNP4a.
Calculation of the maximum lff, which is based on the formula in Section 4.2, for the 3 of 4 loading configuration and uniform loading of fresh fuel at 4.35 wt 0 235U, is summarized in Table 4.7.9 and Table 4.7.11 without soluble boron. Uncertainties associated with depletion (4] The tolerances listed are for the water gap between storage cells. A reduction in the rack water gap causes an equal increase in the storage cell inner dimension. The maximum reduction possible in the rack water gap is -0.21",
as this would make the rack water gap just large enough to fit the metamic insert.
4-20 Holtec Project 1196 Holtec Report HI-2022867 4-20 Holtec Project 1196
(e.g., depletion uncertainty and axial burnup distribution penalty) are not applicable to the Region 3 loading pattern with all fresh fuel of 4.35 wt/ 235U. Results show that the maximum keff of the Region 3 racks is less than 1.0 at a 95% probability at a 95% confidence level with no credit for soluble boron.
4.7.4.6 Determination of the Minimum Bumup for a Single Spent Assembly in the 3 of 4 Loading Pattern To establish a minimum required bumup for the loading pattern with 3 fresh fuel assemblies and one spent fuel assembly, calculations were performed with all assemblies having a maximum nominal initial enrichment of 5.0 wt 0 235U and the single spent fuel assembly having burnup values slightly above and below the expected burnup value. The acceptable burnup for the single spent fuel assembly is then calculated by linear interpolation, based on an appropriate target value (max kff = 0.9958) for the reactivity. All calculations were performed at 0 cooling time; no credit was taken for additional cooling time for the single spent assembly as the reduction in burnup would be minimal. The minimum burnup is shown for 3 of 4 loading in Table 4.7.9.
4.7.4.7 Soluble Boron Concentration for Maximum kef of 0.95 Calculations crediting soluble boron in the spent fuel pool to ensure that the reactivity does not exceed 0.95 are also performed. Calculations are performed at enrichments of 4.35 wt/o 235U and 5.0 wt/ 235U for uniform loading of fresh fuel and a 3 of 4 configuration, respectively, at a soluble boron level of 400 ppm and 800 ppm. The minimum soluble boron requirement is determined by linear interpolation between soluble boron levels to achieve a target maximum kff of 0.9450. In all cases, the maximum keff including all applicable biases and uncertainties is below the regulatory limit of 0.95. The results for each loading pattern in Region 3 is also listed in Table 4.7.10 and Table 4.7.12 for a 3 of 4 configuration and uniform loading of fresh fuel, respectively.
4.7.5 Abnormal and Accident Conditionsfor Region 1, 2 & 3 Racks The effects on reactivity of credible abnormal and accident conditions are examined in this section. This section identifies which of the credible abnormal or accident conditions will result in exceeding the limiting reactivity (keff < 0.95). For those accidents or abnormal conditions that result in exceeding the limiting reactivity, a minimum soluble boron concentration is determined to ensure that keff < 0.95. The double contingency principal of ANS-8.1/N16.1-1975 [4.2] (and the USNRC letter of April 1978) specifies that it shall require at least two unlikely independent and concurrent events to produce a criticality accident. This principle precludes the necessity of considering the simultaneous occurrence of multiple accident conditions.
4-21 Holtec Project 1196 Holtec Report HI-2022867 HI-2022867 4-21 Holtec Project 1196
4.7.5.1 Abnormal Temperature All calculations for Region 1 & 2 are performed at the maximum temperature of 150*F. As shown in Section 4.7.2.4 and 4.7.3.4 above, the temperature coefficient of reactivity is positive, and temperatures above the maximum would cause an increase in the reactivity, and therefore are treated as accidents. Additional calculations for both spent fuel loading and checkerboard loading of fresh fuel at higher temperatures and with a soluble boron content of 400 ppm were performed to determine the minimum soluble boron concentration necessary to ensure that the maximum kcff is below 0.95. The soluble boron content necessary to offset the reactivity effect due to an increase in temperature is shown on Table 4.7.23 and Table 4.7.24 for Region 1 and Region 2, respectively.
All calculations for Region 3 are performed at a pool temperature of 4"C. As shown in Section 4.7.4.4 above, the temperature coefficient of reactivity is negative, therefore any increase in temperature above the minimum would cause a reduction in the reactivity. Table 4.7.22 shows the reactivity effects of increasing the temperature and boiling in the spent fuel pool.
4.7.5.2 Dropped Assembly - Horizontal For the case in which a fuel assembly is assumed to be dropped on top of a rack, the fuel assembly will come to rest horizontally on top of the rack with a minimum separation distance from the active fuel region of more than 12 inches, which is sufficient to preclude neutron coupling (i.e., an effectively infinite separation). Consequently, the horizontal fuel assembly drop accident will not result in a significant increase in reactivity. Furthermore, the soluble boron in the spent fuel pool water assures that the true reactivity is always less than the limiting value for this dropped fuel accident.
4.7.5.3 Dropped Assembly - Vertical It is also possible to vertically drop an assembly into a location that might be occupied by another assembly or that might be empty. Such a vertical impact would at most cause a small compression of the stored assembly, if present, or result in a small deformation of the baseplate for an empty cell. These deformations could potentially increase reactivity. However, the reactivity increase would be small compared to the reactivity increase created by the abnormal location of a fresh assembly discussed in the following section. The vertical drop is therefore bounded by this abnormal location accident and no separate calculation is performed for the drop accident.
4-22 Holtec Project 1196 Holtec Report HI-2022867 Holtec Report HI-2022867 4-22 Holtec Project 1196
4.7.5.4 Abnormal Location of a Fuel Assembly 4.7.5.4.1 Misloaded Fresh Fuel Assembly The misloading of a fresh unburned fuel assembly could, in the absence of soluble poison, result in exceeding the regulatory limit (keff of 0.95). This could possibly occur if a fresh fuel assembly of the highest permissible enrichment (5.0 wt%) were to be inadvertently misloaded into a storage cell intended to be used for spent fuel or misloaded into a storage cell intended to be empty in the checkerboard patterns in Region 1 or Region 2. For the misloading accident in the Region 1 or Region 2 racks filled with spent fuel, enrichment and burnup combinations of 2.0 wto 23 U at 0 years cooling time, 5.0 wt0 U at 0 years cooling time and 5.0 wt/o 235U at 20 years cooling time were analyzed at the appropriate burnup. The calculations for the misloading accident in the Region 3 racks conservatively assume that all spent fuel assemblies are replaced with fresh fuel assemblies.
This configuration will also conservatively bound the misloading accident in the Region 3 rack filled with fresh fuel at 4.35 wt0 235U.
The corresponding calculational model for the Region 1 and Region 2 style storage racks consists of a 5x5 array storage cells with a single, fresh unburned assembly in the center cell. The model is surrounded by periodic boundary conditions, which generates an infinite arrangement of 5x5 arrays with a misloaded assembly. Calculations are performed with 400 ppm, 800 ppm and 1200 ppm (if necessary) soluble boron, and the final soluble boron concentration is determined by linear interpolation.
The corresponding calculational model for the Region 3 style storage racks consists of a 2x2 away of storage cells with a fresh assembly of 5.0 wt0 235U in all cells. The model is surrounded by reflecting boundary conditions, which generates an infinite arrangement of Region 3 cells, all filled with the maximum reactivity assembly. Calculations are performed with 400 ppm and 800 ppm soluble boron, and the final soluble boron concentration is determined by linear interpolation.
4.7.5.4.2 Mislocated Fresh Fuel Assembly The mislocation of a fresh unburned fuel assembly could, in the absence of soluble poison, result in exceeding the regulatory limit (ker of 0.95). This could possibly occur if a fresh fuel assembly of the highest permissible enrichment (5.0 wt%) were to be accidentally mislocated outside of a storage rack adjacent to other fuel assemblies.
For the checkerboard pattern in the Region 1 and Region 2 style storage racks it is assumed that the mislocated assembly is placed adjacent to a storage cell containing another fresh fuel assembly. For the mislocated assembly accident outsideo5.thet/23 Region 5T 1 and Region 2 racks filled with spent 235 fuel, enrichment and burnup combinations of 5.0 wt% 2 U at 0 years cooling time and 5.0 wto U at 20 years cooling time were analyzed at the appropriate burnups.
4-23 Holtec Project 1196 Holtec Report HI-2022867 Holtec Report HI-2022867 4-23 Holtec Project 1196
For the Region 3 racks it is assumed that no metamic panel is located between the mislocated assembly and the assemblies in the rack. For the loading pattern with 3 fresh fuel assemblies and 1 spent fuel assembly, it was assumed that all fresh fuel assemblies are facing the mislocated assembly. This configuration would bound the case of a misplaced assembly with the Region 3 rack filled with fresh fuel of maximum nominal enrichment of 4.35 wt% 235U.
The MCNP4a model consists of a 5x5 array of fuel storage cells with a single fresh, unburned assembly placed adjacent to the rack and a 30cm water reflector. The other three sides of the model consist of reflecting boundary conditions. The mislocated assembly is placed as close to the rack face as possible to maximize the possible reactivity effect. Calculations are performed with 400pm, 800 ppm and 1200 ppm (if necessary) soluble boron, and the final soluble boron concentration is determined by linear interpolation.
4.7.5.5 Loss of All Metamic An additional calculation was performed to determine the reactivity of the Region 3 rack in the unlikely event that the neutron absorber was to be completely absent. Credit was taken for 1600 ppm soluble boron (actual pool soluble boron concentration is higher) and the metamic material was replaced with water. The Region 3 racks without any neutron absorber are analyzed for both the 3 of 4 loading pattern and uniform loading of fresh fuel assemblies having a maximum enrichment of 4.35wt% 235U (identified in Section 4.7.4). The results of this postulated accident condition show that the maximum keff is 0.9388 including bias and uncertainties.
4.7.6 Interfaces Within and Between Racks 4.7.6.1 Normal Conditions In addition to the calculations performed for each individual rack detailed in the preceding sections, the possibility of an increased reactivity effect due to the rack interfaces within and between the racks was determined. Figure 4.5.7 is a layout of the entire ANO Unit 1 spent fuel pool, with the gaps between racks detailed for each interface. The gaps provided in Figure 4.5.7, denoted by a "C" at the rack comers, are measured from the centerline of the adjacent storage cells. Table 4.5.10 summarizes the potential rack interfaces and the gaps between these racks.
The gap distances provided in the last column of Table 4.5.10 are determined from the centerline distances between racks from Figure 4.5.7 and the geometric characteristics of each type of rack.
Figure 4.5.8 illustrates the measurement of the distances between the outside surfaces of the racks.
Table 4.7.26 provides a summary of the various interface calculations performed for the ANO Unit 1 spent fuel pool. Interfaces within the rack include spent and fresh fuel loading patterns within the same rack to determine acceptability. Interface calculations between racks include Holtec Report HI-2022867 4-24 Holtec: Project 1196
Region 1-Region 1, Region 2-Region 2, Region 3-Region 3, Region 1-Region 3 and Region 2-Region 3. Figures 4.7.1 through 4.7.14 are referenced in Table 4.7.26 and provide a visual representation of the interface calculation performed. The figures show the loading pattern assumed in each rack and the value for the water gap between the racks. The calculated reactivity from the interface calculation is then compared to the calculated reactivity from the reference infinite array calculations.
4.7.6.2 Rack Lateral Motion - Seismic Event A seismic event, could, in the absence of soluble boron, result in exceeding the regulatory limit (maximum keff of 0.95). This could possibly occur if the seismic event caused sufficient movement of the rack to a closer proximity. The seismic analysis identifies a maximum differential displacement between racks during a seismic event of 0.635 inches. Selected cases from the interface calculations described in the previous section were chosen to address this potential accident condition. The MCNP4a models described above were modified to reduce the gap between racks by an additional 0.635 inches. Calculations were performed with 800 ppm of soluble boron. The calculated reactivities from MCNP4a show that all calculated reactivities for this accident condition are below 0.90. Even with the addition of the applicable biases and uncertainties, the maximum kff would be below 0.95.
4.7.7 Boron Dilution Evaluation The soluble boron in the spent fuel pool water is conservatively analyzed to contain a minimum of 1600 ppm under operating conditions. Significant loss or dilution of the soluble boron concentration is extremely unlikely, if not incredible. Nonetheless, an evaluation was performed based on the ANO spent fuel pool data.
The required minimum soluble boron concentration is 457 ppm under normal conditions. The volume of water in the pool is approximately 268,000 gallons. Large amounts of unborated water would be necessary to reduce the boron concentration from 1600 ppm to 457 ppm. Abnormal or accident conditions are discussed below for either low dilution rates (abnormal conditions) or high dilution rates (accident conditions). The general equation for boron dilution is, F
C, =Coe v ,
where Ct the boron concentration at time t, Co the initial boron concentration, V is the volume of water in the pool, and F is the flow rate of unborated water into the pool Holtec Report HI-2022867 4-25 Holtec Project 1196
This equation conservatively assumes the unborated water flowing into the pool mixes instantaneously with the water in the pool.
For convenience, the above equation may be re-arranged to permit calculating the time required to dilute the soluble boron from its initial concentration to a specified minimum concentration, which is given below.
t =- lin(Co / C,)
F If V is expressed in gallons and F in gallons per minute (gpm), the time, t, will be in minutes.
4.7.7.1 Low Flow Rate Dilution Small dilution flow around pump seals and valve stems or mis-aligned valves could possibly occur in the normal soluble boron control system or related systems. Such failures might not be immediately detected. These flow rates would be of the order of 2 gpm maximum and the increased frequency of makeup flow might not be observed. However, an assumed loss flow-rate of 2 gpm dilution flow rate would require some 118 days to reduce the boron concentration to the minimum required 457 ppm under normal conditions. Routine surveillance measurements of the soluble boron concentration would readily detect the reduction in soluble boron concentration with ample time for corrective action.
Administrative controls require a measurement of the soluble boron concentration in the pool water at least weekly. Thus, the longest time period that a potential boron dilution might exist without a direct measurement of the boron concentration is 7 days. In this time period, an undetected dilution flow rate of 33.7 gpm would be required to reduce the boron concentration to 457 ppm. No known dilution flow rate of this magnitude has been identified. Further, a total of more than 300,000 gallons of unborated water would be associated with the dilution event and such a large flow of unborated water would be readily evident by high-level alarms and by visual inspection on daily walk-downs of the storage pool area.
4.7.7.2 High Flow Rate Dilution Under certain accident conditions, it is conceivable that a high flow rate of unborated water could flow onto the top of the pool. Such an accident scenario could result from rupture of a unborated water supply line or possibly the rupture of a fire protection system header, both events potentially allowing unborated water to spray onto the pool. A flow rate of up to 2500 gpm could possibly spray onto the spent fuel pool as a result of a rupture of the fire protection line. This would be the most serious condition and bounds all other accident scenarios.
Holtec Report HI-2022867 4-26 Holtec Project 1196
Conservatively assuming that all the unborated water from the break poured onto the top of the pool and further assuming instantaneous mixing of the unborated water with the pool water, it would take approximately 136 minutes to dilute the soluble boron concentration to 457 ppm, which is the minimum required concentration to maintain k1ff below 0.95 under normally operating conditions. In this dilution accident, some 340,000 gallons of water would spill on the auxiliary building floor and into the air-conditioning duct system. Well before the spilling of such a large volume of water, multiple alarms would have alerted the control room of the accident consequences (including the fuel pool high-level alarm, the fire protection system pump operation alarm, and the floor drain receiving tank high level alarm).
Instantaneous mixing of pool water with the water from the rupture of the unborated water supply line is an extremely conservative assumption. Water falling on to the pool surface would mix with the top layer of pool water and the portions of the mixed volumes would continuously spill out of the pool. The density difference between water at 150 TF (maximum permissible pool bulk water temperature) and at the temperature of the unborated water supply is small. This density difference will not cause the water falling on to the pool surface to instantaneously sink down into the racks overcoming the principal driving force for the flow in the pool, which is the buoyancy force generated in the spent fuel pool racks region due to the heat generation from the spent fuel in the racks. This would further enhance the mixing process between the pool water and spilled water above the racks.
For the fire protection system line break, upon the initial break, the fire protection system header pressure would drop to the auto start set point of the fire protection pumps. The start is accompanied with an alarm in the main control room. The annunciator response is to dispatch an operator to find the source of the pump start. Approximately 3 minutes into the event, a spent fuel pool high level alarm would be received in the main control room, assuming that the spent fuel pool level started at the low alarm. The annunciator response for high spent fuel pool level is to investigate the cause. The coincidence of the 2 alarms would quickly lead to the discovery of the failure of the fire protection system and sufficient time to isolate the failure.
The maximum flow rate from demineralized water supply would provide approximately 900 gpm into the spent fuel pool. Failure of the demineralized water header is not accompanied with an alarm; however, the time to dilute the spent fuel pool from 1600 to 457 ppm is greater than the bounding case described above. An alarm on high spent fuel pool level would be received approximately 9 minutes into the event in the main control room, assuming that the spent fuel pool level started at the low alarm. In this scenario, there is sufficient time to isolate the failure and to prevent the spilling of some 340,000 gallons of water.
The analysis assumes that for a double-ended break in the a fire protection system piping, the stream of water will arch through the air some 40 feet falling on top of the pool. This is virtually an incredible event. Should the stream of water fall upon the pool deck, a 3 inch high curb would channel some of the water to the pool drain and prevent all of the water from reaching the pool.
Furthermore, the evaluation also assumes at least 3 independent and concurrent accidents occur simultaneously:
4 Large amount of water flowing from the double-ended pipe break would remain un-detected and is ignored.
Holtec Report HI-2022867 4-27 Holtec Project 1196
- Pool water high level alarms either fail or are ignored.
- Alarms indicating large amounts of water flowing into the floor drain have failed or are ignored.
Considering all related facts, a significant dilution of the pool soluble boron concentration in a short period of time without corrective action is not considered a credible event.
It is not considered credible that multiple alarms would fail or be ignored or that the spilling of large volumes of water would not be observed. Therefore, such a major failure would be detected in sufficient time for corrective action to avoid violation of an administrative guideline and to assure that the health and safety of the public is protected.
4.8 New Fuel Storage Racks Criticality Analysis The New Fuel Storage Vault is intended for the receipt and storage of fresh fuel under normally dry conditions where the reactivity is very low. To assure the criticality safety under accident conditions and to conform to the requirements of General Design Criterion 62, "Prevention of Criticality in Fuel Storage and Handling," two separate criteria must be satisfied as defined in NUREG-0800, Standard Review Plan 9.1.1, "New Fuel Storage." These criteria are as follows:
" When fully loaded with fuel of the highest anticipated reactivity and flooded with clean, unborated water, the maximum reactivity, including uncertainties, shall not exceed a kff of 0.95.
" With fuel of the highest anticipated reactivity in place and assuming optimum hypothetical low density moderation (i.e., fog or foam), the maximum reactivity shall not exceed a keff of 0.98.
The New Fuel Storage Vault provides two 4 x 9 storage rack modules with cell array storage location arranged on a 21 inch lattice spacing. Calculations were made with 238-group NITAWL/KENOSa code package (SCALE 4.3), a three-dimensional Monte Carlo analytical technique, with fresh fuel assemblies with 4.95 wt%/o nominal intitial enrichment. These calculations were made for various moderator densities and the results are shown in Figure 4.8.1; the peak reactivity (optimum moderation) occurs at 9% moderator density. The calculations for the configuration illustrated in Figure 4.8.2 confirms that five locations in each of the storage racks are required to remain empty in order to meet the regulatory limits. Results of the criticality safety analysis are summarized in Table 4.8.1 for the two accident conditions for fuel assemblies of 4.95 +/- 0.05 wt% initial enrichment. The maximum reactivity at 9% moderator density is 0.9726, including uncertainties, which is within the regulatory limit of 0.98, thus confirming the acceptability of the New Fuel Vault for 4.95 +/- 0.05 wt%/o fuel.
Additional calculations at 9% moderator density, performed for the storage pattern depicted in Figure 4.8.3, show that this storage configuration is acceptable for storage of fresh fuel assemblies of up to 4.20 wt0/o enrichment with four locations in each rack array required to remain empty.
Holtec Report HI-2022867 4-28 Holtec Project 1196
For the fully flooded accident condition, calculations are performed as infinite array calculations (i.e., no blocked cells). Under these conditions and with fuel of 4.95 +/- 0.05 wt%/o enrichment, the maximum reactivity, including all uncertainties is less than the regulatory limit of 0.95 for kff, thus confirming the acceptability of the NFV for 4.95 wt/o fuel in the fully flooded accident condition. At 4.2 wt0/o enrichment in the flooded condition, the reactivity will be substantially lower than that for 4.95 +/- 0.05 wt% enrichment and would therefore be acceptable for storage.
4.9 Fuel Handling Equipment Criticality safety evaluations were also performed for handling of fresh fuel assemblies during transfer from the new fuel vault to the reactor core, including the new-fuel elevator, the upender and fuel carriage, and the temporary storage rack within the transfer canal. The new fuel elevator is located on the south wall of the pool facing the Region 1 spent fuel storage racks.
This device can position a fresh fuel assembly 16 inches (assembly center line) from the wall.
The distance from the wall to the edge of the rack is 24.5 inches. A distance of 7.845 inches exists between the centerline of the assembly in the elevator and the edge of the closest fuel storage cell in the rack. The maximum reactivity with fuel in the new fuel elevator (with Region 1 containing a checkerboard of fresh fuel) is 0.9359 with credit for 100 ppm soluble boron.
Additional calculations were performed to evaluate the effect of accidentally dropping or misplacing an assembly adjacent to the new fuel elevator while it is loaded. A most reactive location for the dropped assembly was determined. A credit of 700 ppm boron will ensure k-effective remains below 0.95 should such an event occur. The new fuel elevator therefore meets the criticality acceptance criteria defined in 10 CFR 50.68. The upender/fuel carriage device handles a single assembly. The maximum reactivity of a single fresh assembly containing 4.95 w/o +/- 0.05 enriched fuel in water is bounded by the fresh fuel, fully moderated case in Table 4.8.1, which has a maximum kff of 0.9431. Furthermore for a postulated accident in which a second fresh assembly was positioned near the upender/fuel carriage, the presence of soluble boron (1600 ppm minimum) excludes the possibility of any criticality concern.
The transfer canal incorporates a 7-cell temporary storage rack on a linear array at a 21-1/8 inch spacing (6 locations for fuel assemblies and 1 location for damaged fuel). The maximum k-effective for normal operation of this rack was determined to be 0.9412. Evaluations of a potential mis-placement of a fresh fuel assembly at a position of closest approach to another assembly in the spent fuel rack, separated only by the structure of the temporary rack, shows that the maximum keff (in the absence of any soluble boron) would be 0.9702. The presence of 200 ppm soluble boron would be sufficient to maintain the maximum k-effective below 0.95.
However, the transfer canal, during refueling operations, would always contain the minimum Technical Specification boron concentration (> 2000 ppm), significantly reducing reactivity and further eliminating any criticality concern.
HI-2022867 4-29 Holtec Project 1196 Holtec: Report Holtec Report HI-2022867 4-29 Holtec Project 1196
4.10 REFERENCES
[4.1] M.G. Natrella, Experimental Statistics. National Bureau of Standards, Handbook 91, August 1963.
[4.2] ANS-8.1/NI6.1-1975, "American National Standard for Nuclear Criticality Safety in Operations with Fissionable Materials Outside Reactors," April 14, 1975.
[4.3] J.F. Briesmeister, Editor, "MCNP - A General Monte Carlo N-Particle Transport Code, Version 4A," LA-12625, Los Alamos National Laboratory (1993).
[4.4] "Lumped Fission Product and Pm148m Cross Sections for MCNP," Holtec Report HI-2033031, Rev 0, September 2003.
[4.5] Deleted
[4.6] Deleted
[4.7] M. Edenius, K. Ekberg, B.H. Forssdn, and D. Knott, "CASMO-4 A Fuel Assembly Bumup Program User's Manual," Studsvik/SOA-95/1, Studsvik of America, Inc. and Studsvik Core Analysis AB (proprietary).
[4.8] D. Knott, "CASMO-4 Benchmark Against Critical Experiments," SOA-94/13, Studsvik of America, Inc., (proprietary).
[4.9] D. Knott, "CASMO-4 Benchmark Against MCNP," SOA-94/12, Studsvik of America, Inc., (proprietary).
[4.10] L.I. Kopp, "Guidance on the Regulatory Requirements for Criticality Analysis of Fuel Storage at Light-Water Reactor Power Plants," NRC Memorandum from L. Kopp to T.
Collins, August 19, 1998.
[4.11] Deleted
[4.12] S.E. Turner, "Uncertainty Analysis - Burnup Distributions," presented at the DOE/SANDIA Technical Meeting on Fuel Burnup Credit, Special Session, ANS/ENS Conference, Washington, D.C., November 2, 1988.
4-30 Holtec Project 1196 Report HI-2022867 Holtec Report HI-2022867 4-30 Holtec Project 1196
Table 4.5.1 PWR Fuel Assembly Specifications[5s Fuel Rod Data Assembly type 15x15 Non-HTP 15x15 HTP Fuel pellet outside diameter, in. 0.370 +/- 0.0005 0.3735 +/- 0.0005 Cladding inside diameter, in. 0.377 + 0.002 0.380 +/- 0.002 Cladding outside diameter, in. 0.430 +/- 0.002 0.430 +/- 0.002 Cladding material Zr-4 M5 Stack density, g/cc 10.412 +/- 0.2 10.522 +/- 0.2 Maximum enrichment, wt%5 235 U 5.0+/-_-0.05 5.0+_- _0.05 Fuel Assembly Data Fuel rod array 15xl5 15xl5 Number of fuel rods 208 208 Fuel rod pitch, in. 0.568 +/- 0.0058 0.568 +0.0 1 0 /-0. 0 1 5[61 Number of guide tubes 16 16 Guide Tube outside diameter, 0.530 - 0.002 0.530 - 0.002 in.
Guide Tube inside diameter, in. 0.498 - 0.0026 0.498 + 0.0052 Number of instrument tubes 1 1 Instrument Tube outside 0.493 0.002 0.493 +/- 0.002171 diameter, in. 0.493_+_0.002 0.493__-_0.002_71 Instrument Tube inside 0.441 0.002 0.400 +/- 0.002173 diameter, in. 0.441_+_0.002 0.400__-_0.002 __1 Active fuel Length, in.IS] 140.6-144 142.75 +/- 0.290 t3s Tolerances for fuel enrichment and fuel density are assumed values based on industry standards.
161 Tolerance stated is the tolerance of the total assembly width. The tolerance for each individual fuel rod is determined by dividing this value by the square root of the number of rods of one side of the assembly.
(71 This is the stated value and tolerance for the bottom of the instrument tube. The different instrument tube ID and tolerance for the top half of the assembly has a negligible effect on reactivity.
[81 The active fuel length is conservatively modeled as 144 inches.
4-31 Holtec Project 1196 Holtec Report HI-2022867 HI-2022867 4-31 Holtee: Project 1196
Table 4.5.2 Core Operating Parameters for Depletion Analyses Parameter Non-HTP HTP Soluble Boron Concentration (cycle average), 1000 1000 ppm Reactor Specific Power, MW/MTU 31.4 31.4 Core Average Fuel Temperature, *F 1010 970 Core Average Moderator Temperature at the 603 603 Top of the Active Region, *F In-Core Assembly Pitch, Inches 8.587 8.587 4-32 Holtec Project 1196 Holtec Report HI-2022867 4-32 Holtec Project 1196
Table 4.5.3 Axial Bumup Profile Axial Segment Relative Bumup (cm) Non-HTP HTP Holtec [4.12]
0 to 15.24 0.5000 0.500 0.5485 15.24 to 30.48 0.8477 0.848 0.8477 30.48 to 60.96 1.0500 1.070 1.077 60.96 to 121.92 1.1161 1.130 1.105 121.92 to 182.88 1.1090 1.109 1.098 182.88 to 243.84 1.0909 1.100 1.079 243.84 to 304.80 1.0583 1.080 1.050 304.80 to 335.28 0.9606 0.883 0.9604 335.28 to 350.52 0.7338 0.670 0.7338 350.52 to 365.76 0.4000 0.400 0.467 Report HI-2022867 4-33 Holtec Project 1196 Holtec Report 4-33 Holtec Project 1196
Table 4.5.4 BPRA Data Parameter Value Number of BPRs per assembly 0 or 16 Outer Radius of BPRA Clad (cm) 0.54610 Inner Radius of BPRA Clad (cm) 0.45720 Cladding Material Zr-4 Poison Material B4 C in A120 3 (3.5 wt%)
Pellet Density (g/cm 3) 3.38420 (3.5 wt% B4 C)
Pellet Radius (cm) 0.45720 Table 4.5.5 Weight Percents of BPRA Material (3.5 wt% B4 C)
Material Wt %
Boron-10 0.50063 Boron- 11 2.23809 Carbon 0.76128 Aluminum 51.07266 Oxygen 45.42734 Table 4.5.6 APSR Data Parameter Value Number of APSR rodlets per assembly 16 Clad Outer Radius (cm) 0.55880 Clad Inner Radius (cm) 0.49022 Poison Radius (cm) 0.49022 Poison Density (g/cm 3) 7.9564 Cladding Material SS-304 Poison Material Inconel-600 (76% nickel, 8% iron, 16% chromium) 4-34 Holtec Project 1196 Holtec Report HI-2022867 Holtec Report 4-34 Holtec Project 1196
Table 4.5.7 Fuel Rack Specifications - Region 1 Racks Parameter Value Cell ID, Inches 8.970 +0.025/-0.05 Box Wall Thickness, Inches 0.075 +/- 0.004 Sheathing Thickness, Inches 0.020 +/- 0.004 Poison Pocket Thickness, Inches 0.090 +/- 0.010 Sheathing Width, Inches 7.25 Cell Pitch, Inches 10.650 Water Gap, Inches 1.31 HI-2022867 Report HI-2022867 4-35 Holtec Project 1196 Holtec Report 4-35 Holtec Project 1196
Table 4.5.8 Fuel Rack Specifications - Region 2 Racks Parameter Value Cell ID, Inches 9.116 +0.05/-0.025 Box Wall Thickness, Inches 0.062 +/- 0.004 Cell Pitch, Inches 10.650 Water Gap 1.41 +0.166/-0.221 4-36 Holtec Project 1196 Holtec Report HI-2022867 Holtec 4-36 Holtec Project 1196
Table 4.5.9 Fuel Rack Specifications - Region 3 Racks Parameter Value Cell ID, Inches 9.116 +0.05/-0.025 Box Wall Thickness, Inches 0.062 +/- 0.004 Cell Pitch, Inches 10.650 Water Gap 1.41 +0.166/-0.221 Metamic Insert Width 1.20 +/- 0.05 Metamic Insert Sheathing Thickness 0.02 +/- 0.003 Metamic Poison Thickness 0.100 +/- 0.003 Metamic Poison Width 7.00 +/- 0.062 Metamic Poison B4C Weight Percent 25 : 0.5 4-37 Holtec Project 1196 Holtec Report HI-2022867 HI-2022867 4-37 Holtec Project 1196
Table 4.5.10 Identification of Possible Rack Interaction and Minimum Distances between Racks Rack-to-Rack Center to Center Cell Minimum Distance Interaction Spacing from Figure 4.5.7 Between Racks
[inches] [inches]
Region 1 to Region 1 13 3.66 Region I to Region 3 15.75 5.755 Region 2 to Region 3 12.875 2.225 Region 2 to Region 2 13 2.35 Region 3 to Region 3 13.1875 2.5375 4-38 Holtec Project 1196 Holtec Report HI-2022867 4-38 Holtec: Project 1196
Table 4.7.1 Summary of the Criticality Safety Analyses for Region 1 without Soluble Boron at 0 Years Cooling Time Design Basis Burnup at 5.0 wt% 235U 38.4 GWD/MTU Soluble Boron 0 ppm Uncertainties Bias Uncertainty (95%/95%) +/- 0.0011 Calculational Statistics (95%/95%, 2.Oxa) +/- 0.0010 Fuel Eccentricity + 0.0132 Rack Tolerances - 0.0066 Fuel Tolerances +/- 0.0074 Depletion Uncertainty - 0.0125 Statistical Combination of Uncertaintiest91 +/- 0.0208 Reference keff (MCNP4a) 0.9648 Total Uncertainty (above) 0.0208 Temperature Bias 0.0085 Calculational Bias (see Appendix 4A) 0.0009 Maximum kff 0.9950 Regulatory Limiting kff 1.0000 (9] Square root of the sum of the squares.
4-39 Holtec Project 1196 Holtec Report HI-2022867 Holtec Report HI-2022867 4-39 Holtec Project 1196
Table 4.7.2 Summary of the Criticality Safety Analyses for Region 1 with Soluble Boron at 0 Years Cooling Time Design Basis Burnup, at 5.0 Wt% 211U 38.4 GVM/MTU Soluble Boron 242 ppm Uncertainties Bias Uncertainty (95%/95%) +/- 0.0011 Calculational Statistics (95%/95%, 2.Oxa) +/- 0.0011 Fuel Eccentricity + 0.0132 Rack Tolerances -0.0066 Fuel Tolerances +/- 0.0074 Depletion Uncertainty +/- 0.0125 Statistical Combination of Uncertainties1t 0 ° +/- 0.0208 Reference klff (MCNP4a) 0.9148 Total Uncertainty (above) 0.0208 Temperature Bias 0.0085 Calculational Bias (see Appendix 4A) 0.0009 Maximum l4ff 0.9450 Regulatory Limiting kff 0.9500
[Eo] Square root of the sum of the squares.
4-40 Holtec Project 1196 Holtec Report HI-2022867 4-40 Holtec Project 1196
Table 4.7.3 Summary of the Criticality Safety Analyses for Region 1 without Soluble Boron for a 2x2 Checkerboard of Fresh Fuel and Empty Cells Design Basis Burnup at 5.0 wt% 23U 0 GWD/MTU Soluble Boron 0 ppm Uncertainties Bias Uncertainty (95%/95%) +/- 0.0011 Calculational Statistics (95%/95%, 2.Ox<) +/- 0.0012 Fuel Eccentricity + 0.0046 Rack Tolerances -0.0081 Fuel Tolerances +/- 0.0074 Depletion Uncertainty N/A Statistical Combination of Uncertainties t[q +/- 0.0120 Reference klff (MCNP4a) 0.9329 Total Uncertainty (above) 0.0120 Temperature Bias 0.0101 Calculational Bias (see Appendix 4A) 0.0009 Maximum kff 0.9559 Regulatory Limiting k~fr 1.0000
[El] Square root of the sum of the squares.
4-41 Holtec Project 1196 Holtec Report HI-2022867 4-41 Holtec Project 1196
Table 4.7.4 Summary of the Criticality Safety Analyses for Region 1 with Soluble Boron for a 2x2 Checkerboard of Fresh Fuel and Empty Cells Design Basis Burnup at 5.0 wt/ 2U 0 GWD/MTU Soluble Boron 70 ppm Uncertainties Bias Uncertainty (95%/95%) +/- 0.0011 Calculational Statistics (95%/95%, 2.Oxr) +/- 0.0012 Fuel Eccentricity + 0.0046 Rack Tolerances -0.0081 Fuel Tolerances +/- 0.0074 Depletion Uncertainty N/A Statistical Combination of Uncertainties 1 21 +/- 0.0120 Reference k~ff (MCNP4a) 0.9220 Total Uncertainty (above) 0.0120 Temperature Bias 0.0101 Calculational Bias (see Appendix 4A) 0.0009 Maximum kerr 0.9450 Regulatory Limiting kerr 0.9500
[12] Square root of the sum of the squares.
4-42 Holtec Project 1196 Holtec Report HI-2022867 HI-2022867 4-42 Holtec Project 1196
Table 4.7.5 Summary of the Criticality Safety Analyses for Region 2 without Soluble Boron at 0 Years Cooling Time Design Basis Burnup at 5.0 wt/ 2U 42.7 GWD/MTU Soluble Boron 0 ppm Uncertainties Bias Uncertainty (95%/95%) +/- 0.0011 Calculational Statistics (950/o/95%, 2.Oxo) +/- 0.0011 Fuel Eccentricity + 0.0165 Rack Tolerances -0.0039 Fuel Tolerances + 0.0073 Depletion Uncertainty +/- 0.0139 Statistical Combination of Uncertainties[13] +/- 0.0232 Reference klff (MCNP4a) 0.9614 Total Uncertainty (above) 0.0232 Temperature Bias 0.0093 Calculational Bias (see Appendix 4A) 0.0009 Maximum kef" 0.9948 Regulatory Limiting keff 1.0000
[13] Square root of the sum of the squares.
4-43 Holtec Project 1196 Holtec Report HI-2022867 HI-2022867 4-43 Holtec Project 1196
Table 4.7.6 Summary of the Criticality Safety Analyses for Region 2 with Soluble Boron at 0 Years Cooling Time Design Basis Burnup at 5.0 wt/o 235U 42.7 GWD/MTU Soluble Boron 232 ppm[141 Uncertainties Bias Uncertainty (95%/95%) +/- 0.0011 Calculational Statistics (95%/95%, 2.Oxo) +/- 0.0012 Fuel Eccentricity + 0.0165 Rack Tolerances :h 0.0039 Fuel Tolerances + 0.0073 Depletion Uncertainty - 0.0139 Statistical Combination of Uncertaintiestl[1 +/- 0.0232 Reference klff (MCNP4a) 0.9116 Total Uncertainty (above) 0.0232 Temperature Bias 0.0093 Calculational Bias (see Appendix 4A) 0.0009 Maximum kdf 0.9450 Regulatory Limiting kfn 0.9500 E14] Calculations performed for 5.0 wt%/h fuel with a burnup of 36.2 GWD/MTU at 20 years cooling time, resulted in a slightly higher soluble boron requirement of 233ppm
[iS] Square root of the sum of the squares.
HI-2022867 4-44 Holtec Project 1196 Holtec Report HI-2022867 Holtec Report 4-44 Holtec: Project 1196
Table 4.7.7 Summary of the Criticality Safety Analyses for Region 2 without Soluble Boron for a 2x2 Checkerboard of Fresh Fuel and Empty Cells Design Basis Burnup at 5.0 wt% 235U 0 GWD/MTU Soluble Boron 0 ppm Uncertainties Bias Uncertainty (95%/95%) +/- 0.0011 Calculational Statistics (95%/95%, 2.Oxo) +/- 0.0014 Fuel Eccentricity + 0.0053 Rack Tolerances +/- 0.0049 Fuel Tolerances +/- 0.0071 Depletion Uncertainty N/A Statistical Combination of Uncertainties 1 161 +/- 0.0103 Reference keff (MCNP4a) 0.9431 Total Uncertainty (above) 0.0103 Temperature Bias 0.0110 Calculational Bias (see Appendix 4A) 0.0009 Maximum kff 0.9653 Regulatory Limiting kff 1.0000
[16] Square root of the sum of the squares.
4-45 Holtec Project 1196 Holtec Report 111-2022867 HI-2022867 4-45 Holtec Project 1196
Table 4.7.8 Summary of the Criticality Safety Analyses for Region 2 with Soluble Boron for a 2x2 Checkerboard of Fresh Fuel and Empty Cells Design Basis Burnup at 5.0 wt% 35 U 0 GWD/MTU Soluble Boron 117 ppm Uncertainties Bias Uncertainty (95%/95%) +/- 0.0011 Calculational Statistics (95%/95%, 2.0xa) +/- 0.0014 Fuel Eccentricity + 0.0053 Rack Tolerances -0.0049 Fuel Tolerances +/- 0.0071 Depletion Uncertainty N/A Statistical Combination of Uncertainties [17 +/- 0.0103 Reference kff (MCNP4a) 0.9228 Total Uncertainty (above) 0.0103 Temperature Bias 0.01 10 Calculational Bias (see Appendix 4A) 0.0009 Maximum kerr 0.9450 Regulatory Limiting ker 0.9500 Square root of the sum of the squares.
[117 4-46 Holtec Project 1196 Holtec Report HI-2022867 HI-2022867 4-46 Holtec Project 1196
Table 4.7.9 Summary of the Criticality Safety Analyses for Region 3 without Soluble Boron for a 2x2 Checkerboard of 3 Fresh Fuel Assemblies and 1 Spent Fuel Assembly at 0 Years Cooling Time Design Basis Burnup for Single (5.0 wt%/o) Spent 20.1 GWD/MTU Assembly Soluble Boron 0 ppm Uncertainties Bias Uncertainty (95%/95%) +/- 0.0011 Calculational Statistics (95%/95%, 2.Oxa) +/- 0.0014 Fuel Eccentricity Negative Rack Tolerances + 0.0060 Fuel Tolerances -0.0053 Depletion Uncertainty -0.0012 Statistical Combination of Uncertaintiesp' 8] 0.0082 Reference kerr (MCNP4a) 0.9850 Total Uncertainty (above) 0.0082 Temperature Bias 0.0017 Calculational Bias (see Appendix 4A) 0.0009 Maximum kef 0.9958 Regulatory Limiting kff 1.0000
[IS] Square root of the sum of the squares.
Holtec Report HI-2022867 4-47 Holtec, Project 1196
Table 4.7.10 Summary of the Criticality Safety Analyses for Region 3 with Soluble Boron for a 2x2 Checkerboard of 3 Fresh Fuel Assemblies and 1 Spent Fuel Assembly at 0 Years Cooling Time Design Basis Bumup for Single (5.0 wt0 /o) Spent 20.1 GWD/MTU Assembly Soluble Boron 457 ppm Uncertainties Bias Uncertainty (95%/95%) +/- 0.0011 Calculational Statistics (95%/95%, 2.Oxa) +/- 0.0012 Fuel Eccentricity Negative Rack Tolerances +/- 0.0060 Fuel Tolerances +/- 0.0053 Depletion Uncertainty +/- 0.0012 Statistical Combination of Uncertainties [9 ] +/- 0.0082 Reference krff (MCNP4a) 0.9342 Total Uncertainty (above) 0.0082 Temperature Bias 0.0017 Calculational Bias (see Appendix 4A) 0.0009 Maximum keff 0.9450 Regulatory Limiting ker 0.9500 I19] Square root of the sum of the squares.
4-48 Holtec Project 1196 Holtec Report HI-2022867 4-48 Holtec: Project 1196
Table 4.7.11 Summary of the Criticality Safety Analyses for Region 3 without Soluble Boron Design Basis Burnup at 4.35 wt% 235U 0 GWD/MTU Soluble Boron 0 ppm Uncertainties Bias Uncertainty (95%/95%) +/- 0.0011 Calculational Statistics (95%/95%, 2.Oxa) +/- 0.0014 Fuel Eccentricity Negative Rack Tolerances +/- 0.0059 Fuel Tolerances -0.0052 Depletion Uncertainty N/A Statistical Combination of Uncertainties[20 ] +/- 0.0081 Reference klff (MCNP4a) 0.9860 Total Uncertainty (above) 0.0081 Temperature Bias 0.0019 Calculational Bias (see Appendix 4A) 0.0009 Maximum kef 0.9969 Regulatory Limiting keff 1.0000
[201 Square root of the sum of the squares.
4-49 Holtec Project 1196 Holtec Report HI-2022867 HI-2022867 4-49 Holtec Project 1196
Table 4.7.12 Summary of the Criticality Safety Analyses for Region 3 with Soluble Boron Design Basis Burnup at 4.35 wt 0 Zu 0 GWD/MTU Soluble Boron 409 ppm Uncertainties Bias Uncertainty (95%/95%) +/- 0.0011 Calculational Statistics (95%/95%, 2.0xxa) +/- 0.0012 Fuel Eccentricity Negative Rack Tolerances +/- 0.0059 Fuel Tolerances +/-0.0052 Depletion Uncertainty N/A Statistical Combination of Uncertainties [21 ] 0.0081 Reference kff (MCNP4a) 0.9342 Total Uncertainty (above) 0.0081 Temperature Bias 0.0019 Calculational Bias (see Appendix 4A) 0.0009 Maximum kff 0.9450 Regulatory Limiting kff 0.9500
[211 Square root of the sum of the squares.
4-50 Holtec Project 1196 Holtec Report HI-2022867 4-50 Holtec Project 1196
Table 4.7.13 Burnup Value at which APSRs and BPRAs have Equivalent Reactivity Effect Enrichment Burnup 2.0 9.68 2.5 11.38 3.0 13.06 3.5 14.64 4.0 16.17 4.5 17.58 5.0 19.01 Holtec Report HI-2022867 4-51 Holtec: Project 1196
Table 4.7.14[22]
Minimum Bumup versus Enrichment Values for Region 1 Racks with Spent Fuel Enrichment 2.0 2.5 3.0 3.5 4.0 4.5 5.0 Cooling Time Minimum Bumup (GWD/MTU) 0 2.1 8.6 15.0 21.8 27.2 32.7 38.4 5 2.0 8.2 14.1 20.7 26.2 30.8 36.4 10 1.9 7.9 13.7 19.5 25.5 29.5 34.6 15 1.8 7.7 13.2 18.8 24.7 28.8 33.8 20 1.8 7.5 13.0 18.4 24.2 28.2 33.0
[22] Linear interpolation between burnups for a given cooling time is allowed. However, linear interpolation between cooling times is not allowed, therefore the cooling time of a given assembly must be rounded down to the nearest cooling time.
Holtec Report HI-2022867 4-52 Holtec Project 1196
Table 4.7.15[23]
Minimum Bumup versus Enrichment Values for Region 2 Racks with Spent Fuel Enrichment 2.0 2.5 3.0 3.5 4.0 4.5 5.0 Cooling Time Minimum Bumup (GWD/MTU) 0 4.0 11.2 18.2 25.0 30.1 36.6 42.7 5 3.8 10.6 17.1 23.9 28.8 34.4 40.3 10 3.6 10.1 16.2 22.7 27.8 32.7 38.3 15 3.5 9.8 15.8 21.9 27.1 31.7 37.1 20 3.3 9.6 15.2 21.4 26.6 30.7 36.2 E23)Linear interpolation between burnups for a given cooling time is allowed. However, linear interpolation between cooling times is not allowed, therefore the cooling time of a given assembly must be rounded down to the nearest cooling time.
Holtec Report HI-2022867 4-53 Holtec Project 1196
Table 4.7.16 Reactivity Effect of Insert Type Enrichment 5.0 wt/o 35U, 0 Cooling Time Burnup Insert Type (GWD/MTU) Empty APSR BPRA 0.0 1.20377 1.149 1.07214 1.0 1.18851 1.13469 1.06223 3.0 1.17333 1.12036 1.05558 5.0 1.15866 1.10645 1.04952 7.0 1.14412 1.09265 1.04376 9.0 1.12993 1.0792 1.03855 10.0 1.12298 1.07263 1.03616 12.5 1.10601 1.05661 1.03062 15.0 1.08962 1.04119 1.0255 17.5 1.07355 1.02611 1.02063 20.0 1.0578 1.01138 1.01532 22.5 1.04225 0.9969 1.00902 25.0 1.02684 0.98262 1.00133 27.5 1.01153 0.96848 0.99212 30.0 0.99628 0.95449 0.98152 32.5 0.9811 0.94062 0.96981 35.0 0.96599 0.92689 0.9573 37.5 0.95094 0.91331 0.94426 40.0 0.93597 0.89986 0.93092 42.5 0.92109 0.88659 0.91746 45.0 0.90633 0.8735 0.90398 47.5 0.89171 0.86061 0.89057 50.0 0.87729 0.84796 0.87731 4-54 Holtec Project 1196 Holtee Report HI-2022867 Holtec HI-2022867 4-54 Holtec: Project 1196
Table 4.7.17 Reactivity Effect of Fuel and Rack Tolerances for Region 1 Racks Tolerance 5.0 wt%, 40 GWD/MTU 5.0 wt%, 0 GWD/MTU OCT 0 CT Fuel Tolerance Ak Ak Fuel Density 0.0018 0.0011 Fuel Enrichment 0.0027 0.0019 Fuel Rod Pitch 0.0066 0.0069 Fuel Rod Clad OD 0.0003 0.0011 Fuel Rod Clad ID 0.0002 0.0003 Fuel Pellet OD 0.0003 0.0002 Guide Tube OD 0.0001 0.0002 Guide Tube ID 0.0002 0.0004 Statistical Combination 0.0074 0.0074 Rack Tolerance Ak Ak Cell ID, Constant Water Gap 0.0057 0.0072 Water Gap, Constant Cell Pitch 0.0006 0.0006 Box Wall Thickness 0.0023 0.0028 Sheathing Thickness 0.0020 0.0023 Poison Gap Thickness 0.0001 0.0002 Statistical Combination 0.0065 0.0081 4-55 Holtec Project 1196 Holtec Report HI-2022867 4-55 Holtec: Project 1196
Table 4.7.18 Reactivity Effect of Temperature Variation in Region 1 Racks Temperature (OF) 5.0 wt%, 40 GWD/MTU 5.0 wt%, 0 GWD/MTU 0 CT OCT Ak Ak 32 (0 °C) -0.0150 -0.0178 68 (20 -C) -0.0101 -0.0120 80.33 (300K) -0.0085 -0.0101 150 (max normal temp) Reference Reference 254 (120 -C) 0.0127 0.0146 254 + 10% Void 0.0156 0.0216 Holtec Report HI-2022867 4-56 Holtec Project 1196
Table 4.7.19 Reactivity Effect of Fuel and Rack Tolerances for Region 2 Racks Tolerance 5.0 wt%, 42.5 GWD/MTU 5.0 vt%, 0 GWD/MTU 0 CT OCT Fuel Tolerance Ak Ak Fuel Density 0.0019 0.0010 Fuel Enrichment 0.0027 0.0019 Fuel Rod Pitch 0.0065 0.0066 Fuel Rod Clad OD 0.0002 0.0011 Fuel Rod Clad ID 0.0002 0.0003 Fuel Pellet OD 0.0003 0.0001 Guide Tube OD 0.0001 0.0002 Guide Tube lID 0.0002 0.0004 Statistical Combination 0.0073 0.0071 Rack Tolerance Ak Ak Cell ID, Constant Water Gap 0.0027 0.0035 Water Gap, Constant Cell Pitch 0.0005 0.0007 Box Wall Thickness 0.0028 0.0034 Statistical Combination 0.0039 0.0049 4-57 Holtec Project 1196 Holtec Report 111-2022867 Holtec Report HI-2022867 4-57 Holtec Project 1196
Table 4.7.20 Reactivity Effect of Temperature Variation in Region 2 Racks Temperature (°F) 5.0 wt%, 42.5 GWD/MTU 5.0 wt%, 0 GWD/MTU 0 CT OCT
_Ak Ak 32 (0 °C) -0.0162 -0.0192 68(20 -C) -0.0110 -0.0131 80.33 (300K) -0.0093 -0.0110 150 (max normal temp) Reference Reference 254 (120 -C) 0.0141 0.0161 254 + 10% Void 0.0205 0.0277 HI-2022867 4-58 Holtec Project 1196 Holtec Report Holtec Report HI-2022867 4-58 Holtec Project 1196
Table 4.7.21 Reactivity Effect of Fuel and Rack Tolerances for Region 3 Racks Tolerance 4.35 wt%, 0 GWD/MTU 5.0 wt%, 0 GWD/MTU 0 CT OCT Fuel Tolerance Ak Ak Fuel Density 0.0017 0.0016 Fuel Enrichment 0.0020 0.0016 Fuel Rod Pitch 0.0040 0.0042 Fuel Rod Clad OD 0.0021. 0.0021 Fuel Rod Clad ID 0.0000 0.0000 Fuel Pellet OD 0.0002 0.0002 Guide Tube OD 0.0002 0.0002 Guide Tube ID 0.0006 0.0006 Statistical Combination 0.0052 0.0053 Rack Tolerance Ak Ak Cell ID, Constant Water Gap 0.0001 0.0002 Water Gap, Constant Cell Pitch 0.0039 0.0039 Box Wall Thickness 0.0000 0.0000 Insert Sheathing Thickness 0.0015 0.0015 Insert Water Gap 0.0041 0.0041 Metamic Thickness 0.0003 0.0003 Metamic Width 0.0009 0.0010 Metamic B4C wt%/o 0.0005 Statistical Combination 0.0059 0.0060 4-59 Holtec Project 1196 Report HI-2022867 Holtec Report HI-2022867 4-59 Holtec: Project 1196
Table 4.7.22 Reactivity Effect of Temperature Variation in Region 3 Racks Temperature (°F) 4.35 wt%, 0 GWD/MTU 5.0 wt%, 0 GWD/MTU 0 CT 0 CT Ak Ak 32 (0 0 C) 0.0001 0.0001 39.2 (4 °C) Reference Reference 68 (20 °C) -0.0011 -0.0010 80.33 (300K) -0.0018 -0.0016 150 (max normal temp) -0.0076 -0.0071 254 (120 -C) -0.0202 -0.0194 254 + 10% Void -0.0443 -0.0436 4-60 Holtec Project 1196 Report HI-2022867 Holtec Report 4-60 Holtec Project 1196
Table 4.7.23 Region 1 Accident Conditions Abnormal/Accident Condition Soluble Boron Requirement Abnormal Temperature - Spent Fuel 317 ppm Abnormal Temperature - Fresh Fuel 209 ppm Dropped Assembly - Horizontal Negligible Dropped Assembly - Vertical Negligible Misloaded Assembly - Spent Fuel 514 ppm Misloaded Assembly - Fresh Fuel 804 ppm Mislocated Assembly - Spent Fuel 485 ppm Mislocated Assembly - Fresh Fuel 889 ppm Maximum 889 ppm HI-2022867 4-61 Holtec Project 1196 Holtec Report HI-2022867 4-61 Hottec: Project 1196
Table 4.7.24 Region 2 Accident Conditions Abnormal/Accident Condition Soluble Boron Requirement Abnormal Temperature - Spent Fuel 327 ppm Abnormal Temperature - Fresh Fuel 278 ppm Dropped Assembly - Horizontal Negligible Dropped Assembly - Vertical Negligible Misloaded Assembly - Spent Fuel 544 ppm Misloaded Assembly - Fresh Fuel 867 ppm Mislocated Assembly - Spent Fuel 484 ppm Mislocated Assembly - Fresh Fuel 875 ppm Maximum 875 ppm Holtec Report HI-2022867 4-62 Holtec: Project 1196
Table 4.7.25 Region 3 Accident Conditions Abnormal/Accident Condition Soluble Boron Requirement Abnormal Temperature Negative Dropped Assembly - Horizontal Negligible Dropped Assembly - Vertical Negligible Misloaded Assembly- 3 of 4 Pattern 672 ppm Mislocated Assembly- 3 of 4 Pattern 852 ppm Maximum 852 ppm Holtec Report HI-2022867 4-63 Holtec Project 1196
Table 4.7.26 Interface Calculations Interface Calculation Figure # Reactivity k Reference Delta k Acceptable?
Figure_#Reativit k) Reactivity (k~k) DetkAcptbe Region 1 to Region I with fresh fuel checkerboard in each 47.1 0.9352 0.9329 +0.0023 N rack. Fresh fuel assemblies facing in adjacent racks.
Region 1 - Checkerboard and Spent Fuel in same rack. 4.7.2 0.9605 0.9648 -0.0043 Y Region 2 to Region 2 with fresh fuel checkerboard in each 0.9454 0.9431 +0.0023 N rack. Fresh fuel assemblies facing in adjacent racks.
Region 2 - Checkerboard and Spent Fuel in same rack. 4.7.4 0.9665 0.9670 -0.0005 Y Region 3 to Region 3 with no Metamic Panel in the gap. 3 of 4 pattern with fresh fuel at 5.0 wt% 235U facing each 4.7.5 0.9903 0.9850 +0.0053 N other in both racks.
Region 3 to Region 3 with no Metamic Panel in the gap. 3 of 4 pattern with fresh fuel at 5.0 wt% 235U in one rack 4.7.6 0.9867 0.9850 +0.0017 Y facing fresh and spent fuel in other rack across gap.
Region 3 to Region 3 with no Metamic Panel in the gap.
All fresh fuel at 4.35 wt% 2 35 U in one rack, 3 of 4 pattern 4.7.7 0.9881 0.9860 +0.0021 N with fresh fuel facing gap in other rack.
Region 3 to Region 3 with no Metamic Panel in the gap.
All fresh fuel at 4.35 wt 0 235U in one rack, 3 of 4 pattern 4.7.8 0.9832 0.9860 -0.0028 Y with fresh and spent fuel facing gap in other rack.
Region 1to Region 3, Fresh Fuel Checkerboard in Region 4.7.9 0.9822 0.9850 -0.0028 Y 1 rack, 3 of 4 pattern in Region 3 rack.
Region 1to Region 3, Spent Fuel in Region I rack, 3 of 4 4.7.10 0.9832 0.9850 -0.0018 Y pattern in Region 3 rack. 4.7.10 0.9832_0.9850 -0.0018_Y Region 2 to Region 3, Fresh Fuel Checkerboard in Region 4.7.11 0.9837 0.9850 -0.0013 Y 2 rack, 3 of 4 pattern in Region 3 rack.
Region 2 to Region 3, Spent Fuel in Region 2 rack, 3 of 4 4.7.12 0.9831 0.9850 -0.0019 Y pattern in Region 3 rack. 4.7.12 0._3_0980_0.01_
Region 3 - 3 of 4 and Fresh Fuel 4.35 wt% 235U in same 4.7.13 0.9889 0.9860 +0.0029 N rack. All fresh 5.0 wtO/o facing all fresh 4.35 wt0/o Region 3 - 3 of 4 and Fresh Fuel 4.35 wt% 235U in same rack. Fresh and spent 5.0 wt*/o facing all fresh 4.35 wt% 40 Holtec Report HI-2022867 4-64 Holtec Project 1196
Table 4.8.1 Summary of New Fuel Vault Criticality Safety Analysis OPTIMUM FLOODED OPTIMUM MODERATION MODERATION12 41 MODERATION Initial Enrichment, 4.95 +/- 0.05 4.95 +/- 0.05 4.20 +/- 0.05 wt%
Temperature for 200 C (68 0 F) 20-C (68 0 F) 20 0 C (68°F) analysis Reference keff 0.9652 0.9368 0.9655 Calculational bias, Ak 0.0030 0.0030 0.0030 Uncertainties KENO Bias +/-0.0012 +/-0.0012 +/-0.0012 KENO Statistics +/-0.0006 +/-0.0007 +/-0.0006 Lattice Spacing +/-0.0025 +/-0.0007 +/-0.0016 Fuel Density +/-0.0021 +/-0.0025 +/-0.0021 Fuel Enrichment +/-0.0025 +/-0.0016 +/-0.0019 Statistical Combiation Combination +/-0.0044 +/-0.0033 +/-0.0036 Total keff 0.9682 :k 0.0044 0.9398 +/- 0.0033 0.9685 +/- 0.0036 Maximum k-eff 0.9726 0.9431 0.9721 Regulatory Limit 0.98 0.95 0.98 E243 These calculations were conservatively performed as infinite array calculations. At 4.2 wt0/o enrichment, the flooded condition reactivity would be much lower than the 4.95% case.
111-2022867 Report HI-2022867 Holtec Report 4-65 Holtec Project 1196 Holtec 4-65 Holtec Project 1196
Figure 4.5.1: A Two-Dimensional Representation of the Actual Calculational Model Used for the Region 1 Rack Analysis for Uniform Loading of Spent Fuel. This Figure was Drawn (To Scale) with the Two-Dimensional Plotter in MCNP4a.
Holtec Report HI-2022867 4-66 Holtec Project 1196
bz I
I1 - OMN W--
i-,-*
~III I1 It tII It II I
Figure 4.5.2: A Two-Dimensional Representation of the Actual Calculational Model Used for the Region 1 Rack Analysis for Checkerboard Loading of Fresh Fuel. This Figure was Drawn (To Scale) with the Two-Dimensional Plotter in MCNP4a.
4-67 Holtec Project 1196 Holtec Report 111-2022867 Report HI-2022867 4-67 Holtec: Project 1196
- 1110100* NO,11110111 0O* _ _ _DI
.00 SOSS ~SS0 0**.,,,,,010 Figure 4.5.3: A Two-Dimensional Representation of the Actual Calculational Model Used for the Region 2 Rack Analysis for Uniform Loading of Spent Fuel. This Figure was drawn (To Scale) with the Two-Dimensional Plotter in MCNP4a.
HI-2022867 4-68 Holtec Project 1196 Holtec Report HI-2022867 Holtec Report 4-68 Holtec: Project 1196
Figure 4.5.4: A Two-Dimensional Representation of the Actual Calculational Model Used for the Region 2 Rack Analysis for Checkerboard Loading of Fresh Fuel. This Figure was Drawn (To Scale) with the Two-Dimensional Plotter in MCNP4a.
Holtec Report HI-2022867 4-69 Holtec Project 1196
0@ *@....S.,...
Figure 4.5.5: A Two-Dimensional Representation of the Actual Calculational Model Used for the Region 3 Rack Analysis for Uniform Loading of Fresh Fuel. This Figure was drawn (To Scale) with the Two-Dimensional Plotter in MCNP4a.
4-70 Holtec Project 1196 Holtec Report HI-2022867 Report HI-2022867 4-70 Holtec: Project 1196
I Figure 4.5.6: A Two-Dimensional Representation of the Actual Calculational Model Used for the Region 3 Rack Analysis for "3 of 4" Loading of Spent and Fresh Fuel. This Figure was drawn (To Scale) with the Two-Dimensional Plotter in MCNP4a.
Holtec Report HI-2022867 4-71 Holtec Project 1196
T:241/4 T:25 T: 24 1/2 T: 24 WO 5:24 23 1/2 B: 23 122 6:231/4 rT 2o I~~~ I JI~ I; Is:/2Islif 1
42 LM-244CIM-24D 1 X1xl 111xll 41
.. JiJ.111.11.....t1 I I I I r:liS 1/4 B:
I Region 2 Rack With the Flux Traps r
EI*Th T3JE8 I' 1-r 1~ - T- T - T - - -r r- r- r- T 37
-+- 0 - 9-0 30 37 T: 16 3M 19 308 3:
3 1B:1I 13/1" 8: 191/4 14114 1C: C:13 1M3 T:233 T: 2lSK 1 33 C: -I I it: /3 0/0 T01:11/2
___B: i __ is: /0 1/3 32 1 1 1 31 s4 M-244A i M-244B so 11xlI1 11xll 1:103/ 341 I I I I B: 107818627 Region 2 Rack With the Flux Traps 26
. .---1-- *-I- 4 So 9-I--
T:10/0 23 24
- a. KI I 13
- MR13 9- I-I - -- - --
T: 23 1M R. 1. -J B:10 11a In7 C: 13 1/ C: 131/2 C: 13: /4
!1T Fh 13-I I 1:0M4 23 21
. . . I I1I I I I I 11x12 11x12 I I I 12 30 10 1_ Proposed Location of the Region 3 Rack With I the Inserted Poison Panels J B:l710010 I I I I I I I I I I I I I r: 2 3/4 11 0:19 314 I 4
- 1 C: 10 7/0 1o 1 C: 15718 c .- 1_:187B
- 13 114 5.1 P/18 IC: 10 ¥is I I I ii't
'Fill I I II U: 15 '/4 I:30114 1:114 1301 101 1: 1 C::13 r 1:10 1e1l1 01710 1 7A0 SI I I IT:-10121 13 M-242 7a lOxil
'9'9IM-41zm' I I I Region I Rack with Boraflex Jf 4-4-4--
1-1-t-r: 10015 0: 1011 LI] _:341/ 34
- 1:30110 5:340115
'6118
- 1. 231 247,,e 240M T
-12 5, 24 510 T. 4118:ISI 9:24 718 T: The distance between the outer most top portion of the racks.
6: The distance between the bottom of the racks at the base plots.
C: The distance between the Op ctll centeulines Figure 4.5.7: A Two-Dimensional Representation of the ANO Unit 1 Spent Fuel Pool Layout with Rack Region Layout and Gaps between Adjacent Racks Holtec Report HI-2022867 4-72 Holtec Project 1196
Region 2 Periphery W-ý
!-'-Measured Water Gap Between Region 2 and Region 3 I
Region 3 Periphery Region 3 Periphery Measured Water Gap Between Region 1 and Region 3
.~i.
Region I Periphery Figure 4.5.8: Sketch Illustrating Locations of Measurements of Water Gaps Between Adjacent 5
Racks.[2 ]
E251In measuring the gap between Region 1 and Region 3 the outside of the region 1 racks is the stainless steel sheathing surrounding the Boraflex.
Holtec Report HI-2022867 4-73 Holtec Project 1196
10.650 Pitch Reference 7.25 0.075 +/-0.004 0.090 +/-0.010 8.970 +0.025/-0.05 sq.
0.020 +/-0.004 0.655 Figure 4.5.9: Sketch of Region 1 Racks, Detailing Important Dimensions and Tolerances (NOT TO SCALE, all dimensions in inches)
HI-2022867 4-74 Holtec Project 1196 Report HI-2022867 Holtec Report 4-74 Holtec Project 1196
10.650 Pitch 7.5+/-0.06 0.062+/-0.004 1.41+0.166/-0.221 8.97+0.05/-0.025 sq.
Figure 4.5.10: Sketch of Region 2 Racks, Detailing 26 Important 1
Dimensions and Tolerances. (NOT TO SCALE, all dimensions in inches)r
[261 In order to preserve the pitch due to a conservative reduction of the flux trap gap width from a design reference value of 1.556 inches to 1.41 inches (based on measurements), the nominal cell ID was modeled as 9.116 +0.50/-
0.025 inches.
HI-2022867 4-75 Holtec Project 1196 Report HI-2022867 Holtec Report 4-75 Holtec Project 1196
10.650 I -- 1.20+/-0.05 l g7 0.0 6
.5 _* -- o 0.062+/-0.004 Steel 0.020+/-0.003 0.100+/-0.003 1.41+0.166/-0.221 8.97+0.05/-0.025 sq.
Figure 4.5.11: Sketch of Region 3 Racks, Detailing Important Dimensions and Tolerances. (NOT 27 1 TO SCALE, all dimensions in inches)E In
[271] order to preserve the pitch due to a conservative reduction of the flux trap gap width from a design reference value of 1.556 inches to 1.41 inches (based on measurements), the nominal cell ID was modeled as 9.116 +0.50/-
0.025 inches.
4-76 Holtec Project 1196 Holtec Report HI-2022867 Report HI-2022867 4-76 Holtec: Project 1196
Gap - 3.66" II I Fresh Fuel - 5.0 wt%
Figure 4.7.1: Interface Calculation for Adjacent Region 1 Racks Containing Fresh Fuel Checkerboards with Fresh Fuel Assemblies Facing Across the Gap - NOT ALLOWED No Gap resh Fuel - 5.0 wt%
pent Fuel - Region 1 Figure 4.7.2: Fresh Fuel Checkerboard and Spent Fuel in same Region 1 Rack - ALLOWED Report HI-2022867 Holtec Report Holtec HI-2022867 4-77 4-77 Holtec Project 1196 Holtec Project 1196
Gap - 2.35" Fresh Fuel - 5.0 wt%
Figure 4.7.3: Interface Calculation for Adjacent Region 2 Racks Containing Fresh Fuel Checkerboards with Fresh Fuel Assemblies Facing Across the Gap - NOT ALLOWED No Gap
- resh Fuel - 5.0 wt%
3pent Fuel - Region 2 Figure 4.7.4: Fresh Fuel Checkerboard and Spent Fuel in same Region 2 Rack - ALLOWED Holtec Report HI-2022867 HI-2022867 4-78 4-78 Holtec Project 1196 Holtec Project 1196
Gap - 2.5375" No Metamic Panels In Gap E Fresh Fuel - 5.0 wt%
Spent Fuel - 5.0 wt%, 20.1 GWD/MTU Figure 4.7.5: Interface Calculation for Adjacent Region 3 Racks with 3 of 4 Pattern and Fresh Fuel Facing Across the Gap - NOT ALLOWED Gap - 2.5375" No Metamic Panels In Gap resh Fuel - 5.0 wt%
pent Fuel - 5.0 wt%, 20.1 GWD/MTU Figure 4.7.6: Interface Calculation for Region 3 Racks. Fresh Fuel in one Region 3 Rack Facing Fresh and Spent Fuel in the Adjacent Rack - ALLOWED Holtec HI-2022867 Report HI-2022867 Holtec Report 4-79 4-79 Holtec Project 1196 Holtec Project 1196
Gap - 2.5375" No Metamic Panels In Gap Spent Fuel - 5.0 wt%, 20.1 GWD/MTU i 5.0 wt%
Fresh Fuel - 4.35 wt%
Figure 4.7.7: Interface Calculation for Region 3 Racks. All Fresh Fuel (4.35 wt%/o) in one Rack, 3 of 4 Pattern with Fresh Fuel Facing Gap in Adjacent Rack. - NOT ALLOWED Gap - 2.5375" No Metamic Panels In Gap Spent Fuel - 5.0 wt%, 20.1 GWD/MTU Fresh Fuel Fuel -- 4.35 5.0 wt%
wt%
Figure 4.7.8: Interface Calculation for Region 3 Racks. All Fresh Fuel (4.35 wt%) in one Rack, 3 of 4 Pattern with Fresh and Spent Fuel Facing Gap in Adjacent Rack. - ALLOWED rioiiec I'~epon rlI-LULLZ5c, I 4-80 Holtec Project 1196 Holtec Reportkil-2.02-2867 4-80 Holtec Project 1196
Gap - 5.755" AMMLEI No Metamic Panels In Gap Fresh Fuel - 5.0 wt%
Spent Fuel - 5.0 wt%, 20.1 GWD/MTU Figure 4.7.9: Interface Calculation for Region 1 and Region 3 Racks. Fresh Fuel Checkerboard in Region 1 Rack, 3 of 4 pattern in Region 3 Rack with Fresh Fuel Facing Gap. -
ALLOWED Gap - 5.755" I
No Metamic Panels In Gap Fresh Fuel - 5.0 wt%
Spent Fuel - 5.0 wt%, 20.1 GWD/MTU Spent Fuel for Region 1 Figure 4.7.10: Interface Calculation for Region 1 and Region 3 Racks. Spent Fuel in Region 1 Rack, 3 of 4 Pattern in Region 3 Rack with Fresh Fuel Facing Gap. - ALLOWED Holtec Report HI-2022867 4-81 Holtec Project 1196 HI-2022867 4-81 Holtec Project 1196
Gap - 2.225" No Metamic Panels In Gap Spent Fresh Fuel - 5.0 wt%
wt%, 20.1 GWD/MTU Figure 4.7.11: Interface Calculation for Region 2 and Region 3 Racks. Fresh Fuel Checkerboard in Region 2 Rack, 3 of 4 pattem in Region 3 Rack with Fresh Fuel Facing Gap. -
ALLOWED Gap - 2.225" No Metamic Panels In Gap Spent Fuel - 5.0 wt%, 20.1 GWD/MTU Fresh Fuel for Spent - 5.0Region wt% 2 Figure 4.7.12: Interface Calculation for Region 2 and Region 3 Racks. Spent Fuel in Region 2 Rack, 3 of 4 Pattern in Region 3 Rack with Fresh Fuel Facing Gap. - ALLOWED 4-82 Holtec Project 1196 Holtec ~eport noitec HI-2022867I Report tii-LU21~~ 4-82 Holtec Project 1196
No Gap Fresh Fuel - 5.0 wt%
Spent Fuel - 5.0 wt%, 20.1 GWD/MTU Fresh Fuel - 4.35 wt%
Figure 4.7.13: 3 of 4 Loading Pattern and Fresh Fuel (4.35 wtO 235U) in same Region 3 Rack, All fresh 5.0 wt% facing all fresh 4.35 wt% - NOT ALLOWED No Gap Fresh Fuel - 5.0 wt%
Spent Fuel - 5.0 wt%, 20.1 GWD/MTU Fresh Fuel - 4.35 wt%
Figure 4.7.14: 3 of 4 Loading Pattern and Fresh Fuel (4.35 wt% 235U) in same Region 3 Rack, Fresh and spent 5.0 wt% facing all fresh 4.35 wt% - ALLOWED Holtec Report HI-2022867 4-83 Holtec Project 1196
0 0 - - -- - - - -
- 1. - - -
0.95 - - . . , - -* - ,, ,
0U90 - - - - -- . :
0.85----
0 13 0.8 0.7 0.70 --.
10 10' 0.65f I - - A 1 Z4 Percent Moderato Densiy Figure 4.8.1: Reactivity of the New Fuel Vault as a Function of Moderator Density for 4.95 wt0/o Fuel.
Holtec Report HI-2022867 4-84 Holtec Project 1196 Holtec Project 1196
Nt 8
7 6
5 x x x x x 4 x x x x x 3
2 1
A B C D E F G H K Figure 4.8.2: Acceptable New Fuel Storage Vault Configuration for up to 4.95 wt%
Enrichment Fresh Fuel.
Note: X's show the locations where fuel assemblies will not be stored.
Nt 8
7 6
5 4
3 2
1 Figure 4.8.3: Acceptable New Fuel Storage Vault Configuration for up to 4.2 wt0/o Enrichment Fresh Fuel.
Note: X's show the locations where fuel assemblies will not be stored.
Holtec Report HI-2022867 4-85 Holtec Project 1196
APPENDIX 4A: BENCHMARK CALCULATIONS 4A. 1 INTRODUCTIQN AND
SUMMARY
Benchmark calculations have been made on selected critical experiments, chosen, in so far as possible, to bound the range of variables in the rack designs. Two independent methods of analysis were used, differing in cross section libraries and in the treatment of the cross sections. MCNP4a [4A. 1] is a continuous energy Monte Carlo code and K.NO5a 14A.2]
uses group-dependent cross sections. For the KENO5a analyses reported here, the 238-group library was chosen, processed through the NITAWL-II [4A.2] program to create a working library and to account for resonance self-shielding in uranium-238 (Nordheim integral treatment). The 238 group library was chosen to avoid or minimize the errorst (trends) that have been reported (e.g., [4A.3 through 4A.5]) for calculations with collapsed cross section sets.
In rack designs, the three most significant parameters affecting criticality are (1) the fuel enrichment, (2) the '%Bloading in the neutron absorber, and (3) the lattice spacing (or water-gap thickness if a flux-trap design is used). Other parameters, within the normal range of rack and fuel designs, have a smaller effect, but are also included in the analyses.
Table 4A. 1 summarizes results of the benchmark calculations for all cases selected and analyzed, as referenced in the table. The effect of the major variables are discussed in subsequent sections below. It is important to note that there is obviously considerable overlap in parameters since it is not possible to vary a single parameter and maintain criticality; some other parameter or parameters must be concurrently varied to maintain criticality.
One possible way of representing the data is through a spectrum index that incorporates all of the variations in parameters. KENO5a computes and prints the "energy of the average lethargy causing fission" (EALF). In MCNP4a, by utilizing the tally option with the identical 238-group energy structure as in KENO5a, the number of fissions in each group may be collected and the EALF determined (post-processing).
Small but observable trends (errors) have been reported for calculations with the 27-group and 44-group collapsed libraries. These errors are probably due to the use of a single collapsing spectrum when the spectrum should be different for the various cases analyzed, as evidenced by the spectrum indices.
Appendix 4A, Page I
Figures 4A.1 and 4A.2 show the calculated kff for the benchmark critical experiments as a function of the EALF for MCNP4a and KENO5a, respectively (U0 2 fuel only). The scatter in the data (even for comparatively minor variation in critical parameters) represents experimental errort in performing the critical experiments within each laboratory, as well as between the various testing laboratories. The B&W critical experiments show a larger experimental error than the PNL criticals. This would be expected since the B&W criticals encompass a greater range of critical parameters than the PNL criticals.
Linear regression analysis of the data in Figures 4A. 1 and 4A.2 show that there are no trends, as evidenced by very low values of the correlation coefficient (0.13 for MCNP4a and 0.21 for KENQ5a). The total bias (systematic error, or mean of the deviation from a kl of exactly 1.000) for the two methods of analysis are shown in the table below.
Calculational Bias of MCNP4a and KENOSa MCNP4a 0.0009+0.0011 KENO5a 0.0030+/-0.0012 The bias and standard error of the bias were derived directly from the calculated lkr values in Table 4A. 1 using the following equations", with the standard error multiplied by the one-sided K-factor for 95 % probability at the 95 % confidence level from NBS Handbook 91 [4A. 18] (for the number of cases analyzed, the K-factor Is -2.05 or slightly more than 2).
(4A.1)
A classical example of experimental error is the corrected enrichment in the PNL experiments, first as an addendum to the initial report and, secondly, by revised values in subsequent reports for the same fuel rods.
tt These equations may be found in any standard text on statistics, for example, reference
[4A.6] (or the MCNP4a manual) and is the same methodology used in MCNP4a and in KENO5a.
Appendix 4A, Page 2
I-va k2_(E
- 1 t,)2 In (4A.2) n (n-1)
Bias = (I- ") d- Ko (4A.3) where k, are the calculated reactivities of n critical experiments; o; is the unbiased estimator of the standard deviation of the mean (also called the standard error of the bias (mean)); K is the one-sided multiplier for 95 % probability at the 95 % confidence level (NBS Handbook 91 [4A. 18]).
Formula 4.A.3 is based on the methodology of the National Bureau of Standards (now NIST) and is used to calculate the values presented on page 4.A-2. The first portion of the equation, ( 1- kc ), is the actual bias which is added to the MCNP4a and KENO5a results.
The second term, Koi, is the uncertainty or standard error associated with the bias. The K values used were obtained from the National Bureau of Standards Handbook 91 and are for one-sided statistical tolerance limits for 95 % probability at the 95 % confidence level. The actual K values for the 56 critical experiments evaluated with MCNP4a and the 53 critical experiments evaluated with KENO5a are 2.04 and 2.05, respectively.
The bias values are used to evaluate 1he maximum ki, values for the rack designs.
KENO5a has a slightly larger systematic error than MCNP4a, but both result in greater precision than published data [4A.3 through 4A.5] would indicate for collapsed cross section sets in KENO5a (SCALE) calculations.
4A.2 Effect of Enrichment The benchmark critical experiments include those with enrichments ranging from 2.46 w/o to 5.74 w/o and therefore span the enrichment range for rack designs. Figures 4A.3 and 4A.4 show the calculated kfr values (Table 4A.1) as a function of the fuel enrichment reported for the critical experiments. Linear regression analyses for these data confirms that there are no trends, as indicated by low values of the correlation coefficients (0.03 for MCNP4a and 0.38 for KENO5a). Thus, there are no corrections to the bias for the various enrichments.
Appendix 4A, Page 3
As further confirmation of the absence of any trends with enrichment, a typical configuration was calculated with both MCNP4a and KENO5a for various enrichments.
The cross-comparison of calculations with codes of comparable sophistication is suggested in Reg. Guide 3.41. Results of this comparison, shown in Table 4A.2 and Figure 4A.5, confirm no significant difference in the calculated values of k., for the two independent codes as evidenced by the 450 slope of the curve. Since it is very unlikely that two independent methods of analysis would be subject to the same error, this comparison is considered confirmation of the absence of an enrichment effect (trend) in the bias.
4A.3 Effect of I°B Loading Several laboratories have performed critical experiments with a variety of thin absorber panels similar to the Boral panels in the rack designs. Of these critical experiments, those performed by B&W are the most representative of the rack designs. PNL has also made some measurements with absorber plates, but, with one exception (a flux-trap experiment),
the reactivity worth of the absorbers in the PNL tests is very low and any significant errors that might exist in the treatment of strong thin absorbers could not be revealed.
Table 4A.3 lists the subset of experiments using thin neutron absorbers (from Table 4A. 1) and shows the reactivity worth (Ak) of the absorber.t No trends with reactivity worth of the absorber are evident, although based on the calculations shown in Table 4A.3, some of the B&W critical experiments seem to have unusually large experimental errors. B&W made an effort to report some of their experimental errors. Other laboratories did not evaluate their experimental errors.
To further confirm the absence of a significant trend with 10B concentration in the absorber, a cross-comparison was made with MCNP4a and KENO5a (as suggested in Reg.
Guide 3.41). Results are shown in Figure 4A.6 and Table 4A.4 for a typical geometry.
These data substantiate the absence of any error (trend) in either of the two codes for the conditions analyzed (data points fall on a 45 0 line, within an expected 95 % probability limit).
The reactivity worth of the absorber panels was determined by repeating the calculation with the absorber analytically removed and calculating the incremental (Ak) change in reactivity due to the absorber.
Appendix 4A, Page 4
4A.4 Miscellaneous and Minor Parameters 4A.4.1 Reflector Material and Spacings PNL has performed a number of critical experiments with thick steel and lead reflectors.t Analysis of these critical experiments are listed in Table 4A.5 (subset of data in Table 4A. 1). There appears to be a small tendency toward overprediction of k, at the lower spacing, although there are an insufficient number of data points in each series to allow a quantitative determination of any trends. The tendency toward overprediction at close spacing means that the rack calculations may be slightly more conservative than otherwise.
4A.4.2 Fuel Pellet Diameter and Lattice Pitch The critical experiments selected for analysis cover a range of fuel pellet diameters from 0.311 to 0.444 inches, and lattice spacings from 0.476 to 1.00 inches. In the rack designs, the fuel pellet diameters range from 0.303 to 0.3805 inches O.D. (0.496 to 0.580 inch lattice spacing) for PWR fuel and from 0.3224 to 0.494 inches O.D. (0.488 to 0.740 inch lattice spacing) for BWR fuel. Thus, the critical experiments analyzed provide a reasonable representation of power reactor fuel. Based on the data in Table 4A. 1, there does not appear to be any observable trend with either fuel pellet diameter or lattice pitch, at least over the range of the critical experiments applicable to rack designs.
4A.4.3 Soluble Boron Concentration Effects Various soluble boron concentrations were used in the B&W series of critical experiments and in one PNL experiment, with boron concentrations ranging up to 2550 ppm. Results of MCNP4a (and one KENQ5a) calculations are shown in Table 4A.6. Analyses of the very high boron concentration experiments (> 1300 ppm) show a tendency to slightly overpredict reactivity for the three experiments exceeding 1300 ppm. In turn, this would suggest that the evaluation of the racks with higher soluble boron concentrations could be slightly conservative.
Parallel experiments with a depleted uranium reflector were also performed but not included in the present analysis since they are not pertinent to the Holtec rack design.
Appendix 4A, Page 5
4A.5 MOX Fuel The number of critical experiments with PuO2 bearing fuel (MOX) is more limited than for U0 2 fuel. However, a number of MOX critical experiments have been analyzed and the results are shown in Table 4A.7. Results of these analyses are generally above a k, of 1.00, indicating that when Pu is present, both MCNP4a and KENO5a overpredict the reactivity. This may indicate that calculation for MOX fuel will be expected to be conservative, especially with MCNP4a. It may be noted that for the larger lattice spacings, the KENQ5a calculated reactivities are below 1.00, suggesting that a small trend may exist with KENO5a. It is also possible that the overprediction in kr, for both codes may be due to a small inadequacy in the determination of the Pu-241 decay and Am-241 growth. This possibility is supported by the consistency in calculated klf over a wide range of the spectral index (energy of the average lethargy causing fission).
Appendix 4A, Page 6
4A.6 References
[4A. 1] J.F. Briesmeister, Ed., "MCNP4a - A General Monte Carlo N-Particle Transport Code, Version 4A; Los Alamos National Laboratory, LA-12625-M (1993).
[4A.2] SCALE 4.3, "A Modular Code System for Performing Standardized Computer Analyses for Licensing Evaluation%, NUREG-0200 (ORNL-NUREG-CSD-21U21R5, Revision 5, Oak Ridge National Laboratory, September 1995.
[4A.3] M.D. DeHart and S.M. Bowman, "Validation of the SCALE Broad Structure 44-G Group ENDF/B-Y Cross-Section Library for Use in Criticality Safety Analyses", NUREG/CR-6102 (ORNL/TM-12460)
Oak Ridge National Laboratory, September 1994.
[4A.41 W.C. Jordan et al., "Validation of KENOV.a", CSD/TM-238, Martin Marietta. Energy Systems, Inc., Oak Ridge National Laboratory, December 1986.
[4A.5] O.W. Hermann et al., "Validation of the Scale System for PWR Spent Fuel Isotopic Composition Analysis", ORNL-TM-12667, Oak Ridge National Laboratory, undated.
[4A.6] R.J. Larsen and M.L. Marx, An Introduction to Mathematical Statistics and its Applications, Prentice-Hall, 1986.
[4A.7] M.N. Baldwin et al., Critical Experiments Supporting Close Proximity Water Storage of Power Reactor Fuel, BAW-1484-7, Babcock and Wilcox Company, July 1979.
[4A.8] G.S. Hoovier et al., Critical Experiments Supporting Underwater Storage of Tightly Packed Configurations of Spent Fuel Pins, BAW-1645-4, Babcock & Wilcox Company, November 1991.
[4A.9] L.W. Newman et al., Urania Gadolinia: Nuclear Model Development and Critical Experiment Benchmark, BAW-1810, Babcock and Wilcox Company, April 1984.
Appendix 4A, Page 7
[4A. 10] J.C. Manaranche et al., "Dissolution and Storage Experimental Program with 4.75 w/o Enriched Uranium-Oxide Rods," Trans.
Am. Nucl. Soc. 33: 362-364 (1979).
[4A.11] S.R. Bierman and E.D. Clayton, Criticality Experiments with Subcritical Clusters of 2.35 wlo and 4.31 w/o 2"nUEnriched UO2 Rods in Water with Steel Reflecting Walls, PNL-3602, Battelle Pacific Northwest Laboratory, April 1981.
[4A. 12] S.R. Bierman et al., Criticality Experiments with Suberitical Clusters of 2.35 w/o and 4.31 w/o 2U Enriched U0 2 Rods in Water with Uranium or Lead Reflecting Walls, PNL-3926, Battelle Pacific Northwest Laboratory, December, 1981.
[4A. 13] S.R. Bierman et al., Critical Separation Between Suberitical Clusters of 4.31 w/o 233U Enriched U0 2 Rods in Water with Fixed Neutron Poisons, PNL-2615, Battelle Pacific Northwest Laboratory, October 1977.
[4A. 14] S.R. Bierman, Criticality Experiments with Neutron Flux Traps Containing Voids, PNL-7167, Battelle Pacific Northwest Laboratory, April 1990.
[4A.15] B.M. Durst et al., Critical Experiments with 4.31 wt % 23sU Enriched U0 2 Rods in Highly Borated Water Lattices, PNL-4267, Battelle Pacific Northwest Laboratory, August 1982.
[4A. 16] S.R. Bierman, Criticality Experiments with Fast Test Reactor Fuel Pins in Organic Moderator, PNL-5803, Battelle Pacific Northwest Laboratory, December 1981.
[4A. 17] E.G. Taylor et al., Saxton Plutonium Program Critical Experiments for the Saxton Partial Plutonium Core, WCAP-3385-54, Westinghouse Electric Corp., Atomic Power Division, December 1965.
[4A. 18] M.G. Natrella, Experimental Statistics, National Bureau of Standards, Handbook 91, August 1963.
Appendix 4A, Page 8
Table 4A.1 Summary of Criticality Benchmark Calculations Calmired k-5 SMAL t (eVm Reference Identification Enrich. MCNP4a 1=511 MCNP4a KENO5a B&W-1484 (4A.7) Core 1 2.46 0.9964.4 0.0010 0.9898+/- 0.0006 0.1759 0.1753 I
Core II 2.46 1.0008+/-0.0011 1.0015 0.0005 0.2M553 0.2446 2 B&W-1494 (4A.7)
Core M 2.46 1.0010 0.0012 1.0005 +/- 0.0005 0.1999 0.1939 3 B&W-1484 (4A.7)
Core IX 2.46 0.9956 0.0012 0.9901 0.0006 0.1422 0.1426 4 R&W-1484 (4A.7)
Core X 2.46 0.9980 - 0.0014 0.9922 +/- 0.0006 0.IM13 0.1499 5 B&W-1484 (4A.7)
Core XI 2.46 0.9978 +0.0012 1.0005 -0.0005 0.2031 0.1947 6 B&W-1484 (4A.7)
Core X1I 2.46 0.9998 +/-0.0011 0.9978 0.0006 0.1718 0.1662 7 B&W-1484 (4A.7)
Core KM 2.46 1.0020 +/-0.0010 0.9952 +/- 0.0006 0.1988 0.1965 8 B&W-1484 (4A.7)
Core XIV 2.46 0.9953 +/-0.0011 0.9928 0.0006 0.2022 0.1986 9 B&W-1484 (4A.7)
Core XV" 2.46 0.9910". 0.0011 0.9909 + 0.0006 0.2092 0.2014 10 B&W-1484 (4A.7)
Core XVI" 2.46 0.9935 +/-0.0010 0.9889 0.0006 0.1757 0.1713 11 B&W-1434 (4A.7)
Core XVII 2.46 0.9962 0.0012 0.9942 0.0005 0.2083 0.2021 12 B&W-1484 (4A.7)
Core XVIII 2.46 1.0036 0.0012 0.9931+/-0.0006 0.1705 0.1708 13 B&W-1484 (4A,7)
Appendix 4A, Page 9
Table 4A.1 Summary of Criticality Benchmark Calculations Calculated I. F.A.LF (eVa MCNP4a KENOSa Reference Identification MCNP4a KENOSa Core XIX 2.46 0.9961 +/- 0.0012 0.9971 +/- 0.0005 0.2103 0.2011 14 B&W-1484 (4A.7) 2.46 1.0008 - 0.0011 0.9932 - 0.0006 0.1724 0.1701 15 B&W-1484 (4A.7) Core XX 2.46 0.999 4* 0.0010 0.9918 +/- 0.0006 0.1344 0.1536 16 B&W-1484 (4A.7) Core XXI 2.46 0.9970 +/- 0.0010 0.9924 +/- 0.0006 1.4475 1.4680 17 B&W-1645 (4A.8) S-type Fuel, w/86 ppm D 2.46 0.9990 0.0010 0.9913 +/- 0.0006 1..463 1.5660 18 B&W-1645 (4A.8) S-type Fuel, w/746 ppm B 2.46 0.9972 0.0009 0.9949 0.0005 0.4241 0.4331 19 B&W-1645 (4A.8) SO-type Fuel, w/1156 ppm B 2.46 1.0023 - 0.0010 NC 0.1531 NC 20 B&W-1810 (4A.9) Case 1 1337 ppm B 2.A614.02 1.0060 +/- 0.0009 NC 0.4493 NC 21 B&W-110 (4A.9) Case 12 1899 ppm B 4.75 0.9966 0.0013 NC 0.2172 NC 22 French (4A.10) Water Moderator 0 ap 4.75 0.9952 - 0.0012 NC 0.1778 NC 23 French (4A.10) Water Moderator L. cm gap gap 4.75 0.9943 +/-0.0010 - NC 0.1677 NC 24 French (4A.10) Water Modertor 5n 4.75 0.9979 +/-0.0010 NC 0.1736 NC 25 French (4A.10) Water Moderator 10 cm gap 2.35 NC 1.0004 +/- 0.0006 NC 0.1018 26 PNL-3602 (4A.11) Steel Reflector, 0 separatn Appendix 4A, Page 10
Table 4A.1 Summary of Criticality Benchmark Calculations Calculated ho EALF t eVI Enrich. MCNP4a KENOSa MCNP4a KlMOSa Reference Identification 2.35 0.9980 +/- 0.0009 0.9992 +/- 0.0006 0.1000 0.0909 27 PNL-3602 (4A.11) Steel Reflector, 1321 cm sep.
2.35 0.9968 +/- 0.0009 0.9964 +/- 0.0006 0.0981 0.0975 28 PNL-3602 (4A.11) Steel Reflector, 2.616 cm sepn 2.35 0.9974 +/- 0.0010 0.9980 +/- 0.0006 0.0976 0.0970 29 PNL-3602 (4A.11) Steel Reflector, 3.912 cm sepn.
2.35 0.9962 +/- 0.0008. 0.9939 +/- 0.0006 0.0973 0.0968 30 PNL-3602 (4A.11) Steel Reflector, Infinite sepn.
4.306 NC 1.0003 0.0007 NC 03282 31 PNL-3602 (4A.11) Steel Reflector, 0 cm sepn.
4.306 0.9997 +/-0.0010 1.0012 +/- 0.0007 0.3016 0.3039 32 PNL-602 (4A.11) Steel Reflector, IM1 cm sepn.
4.306 0.9994 - 0.0012 0.9974 +/- 0.0007 0.2911 0.2927 33 PNL-3602 (4A.11) Steel Reflector, 2.616 cm sepn.
4.306 0.9969 +/- 0.0011 0.9951 +/- 0.0007 0.2828 0.2860 34 (4A.11)
,NL-3602 Steel Reflector, 5.405 cm selm.
4.306 0.9910 +/- 0.0020 0.9947 +/- 0.0007 0.2M51 0.2864 35 PNL-3602 (4A.11) Steel Reflector, Ififite sepn. "
4.306 0.9941 +/- 0.0011 0.9970 +/- 0.0007 0.3135 0.3150 36 PNL-3602 (4A.11) Steel Reflector, with DoradSheets 0 cm sepn. 4.306 NC 1.0003 +/- 0.0007 NC 0.3159 37 PNL-3926 (4A.12) Lead Reflector, 4.306 1.0025 +/- 0.0011 0.9997 0.0007 0.3030 0.3044 38 PNL-3926 (4A.12) Lead Reflector, 0.55 cm sepl.
4.306 1.0000 +/- 0.0012 0.9985 +/- 0.0007 0.2883 0.2930 39 PNL-3926 (4A.12) Lead Reflector, 1.956 cm sepn.
Appendix 4A, Page 11
Table 4A.1 Summary of Criticality Benchmark Calculations Cal uaed k-. EALF*t (eV)
Reference MdentlfMenfon Enrich. MCNP4a KHNO5a MCNP4a KENO5a 40 PNL-3926 (4A"12) Lead Reflector, 5.405 cm sepn. 4.306 0.9971 +/- 0.0012 0.9946 0.0007 0.2831 0.2854 Experiment 0041032 - no absorber 4.306 0.9925 +/- 0.0012 0.9950 +/- 0.0007 0.1155 0.1159 41 PNL-2615 (4A.13)
Experiment 030 - Zr plates 4.306 NC 0.9971+/- 0.0007 NC 0.1154 42 PNL-2615 (4A.13)
Experiment 013 - Steel plates 4.306 NC 0.9965 +/-0.0007 NC 0.1164 43 PN'L-2615 (4A.13)
Experiment 014 - Steel plates 4.306 NC 0.9972 +/- 0.0007 NC 0.1164 44 PNL-2615 (4A.13) 45 r-qL2615 (4A.13) ENp. 009 1.05% BonSt*eel plates 4.306 0.9982 +/- 0.0010 0.9 +/- 0.0007 0.1172 0.1162 46 PNL-2615 (4A.13) Exp. 012 1.62% Boron-Steel plates 4.306 0.9996 +/- 0.0012 0."92 +/- 0.0007 0.1161 0.1173 Exp. 031 - Bloral plates 4.306 0.9994 +/- 0.0012 0.9969 ::0.0007 0.1165 0.1171 47 PMIL2615 (4A.13)
Experiment 214R - with flux trap 4.306 0.9991 +/- 0.0011 0.9956 +/- 0.0007 03722 0.3812 48 PNL-7167 (4A.14)
Experiment 214V3 - with flux trap 4.306 0.9969 +/- 0.0011 0.9963 :10.0007 0.3742 0.3826 49 PNL-7167 (4A.14)
Case 173 - 0 ppm B 4.306 0.9974 +/- 0.0012 NC 0.283 NC 50 PNL-4267 (4A.15)
PNL-4267 (4A.15) Case 177 - 2SSO ppm B 4.306 1.0057+/- 0.0010 NC 0.5509 NC 51 MOX Fuel - Type 3.2 Exp. 21 20% Pu 1.0041 0.0011 1.0046 +/- 0.0006 0.9171 0.8868 52 PNL-5903 (4A.16)
Appendix 4A. Page 12
Table 4A.1 Summary of Criticality Benchmark Calculations Calculated k- RALMt (-Vf Identification Enrich. MCNP4a KENOSa MCNP4a KENO5a Reference 53 PNL.S803 (4A.16) MOX Fuel - Type 3.2 Exp. 43 20% Pu 1.0053 + 0.0012 1.0036 +/- 0.0006 0.2968 0.2944 MOX Fuel - Type 3.2 Exp. 13 20% Pu 1.0083 +/- 0.0011 0.9989 +/- 0.0006 0.1665 0.1706 54 PNL-5803 (4A.16)
MOX Fuel - Type 3.2 Exp. 32 20% Pu 1.0079 +/- 0.0011 0.9966 +/- 0.0006 0.1139 0.1165 55 PNL-5'03 (4A.16) 6.6% Pa 0.9996 +/- 0.0011 1.0005 +/- 0.0006 0.8665 0.8417 56 WCAP-3385 (4A.17) Saxton Case 52 FuO2 0.52" pitch 5.74 1.0000 +/- 0.0010 0.9956 0.0007 0.4476 0.4580 57 WCAP-33*5 (4A.17) Saxton Case 52 U 0.52" pitch 6.6% Pa 1.0036 +/- 0.0011 1.0047 0.0006 0.5289 0.5197 58 WCAP-3385 (4A.17) Saxton Case 56 Pu02 0.56" pitch 6.6% Pa 1.0008 +/- 0.0010 NC 0.6389 NC 59 WCAP-3385 (4A.17) Sexton Case 56 borated PuO2 5.74 0.9994 +/- 0.0011 0.9967 +/- 0.0007 0.2923 0.2954 60 WCAP-3385 (4A.17) Saxton Case 56 U 0.56" pitch 6.6% Pu 1.0063 +/- 0.0011 1.0133 +/- 0.0006 0.1520 0.1555 61 WCAP-338S (4A.17) Saxton Case 79 PMO2 0.79" pitch 5.74 1.0039 +/- 0.0011 1.0008 +/- 0.0006 0.1036 0.1047 62 WCAP-3385 (4A.17) Saxton Case 79 U 0.79" pitch Notes: NC stands for not calculated.
t EALF is the energy of the average lethargy causing fission.
experimental
- These experimental results appear to be statistical outliers (>36) suggesting the possibility of unusually large the calculational error. Although they could justifiably be excluded, for conservatism, they were retained in determining basis.
Appendix 4A, Page 13
Table 4A.2 COMPARISON OF MCNP4a AND KENO5a CALCULATED REACTIVITIES' FOR VARIOUS ENRICHMENTS Calculated kl +/- la Enrichment MCNP4a KENOSa 3.0 0.8465 + 0.0011 0.8478 +/- 0.0004 3.5 0.8820 +/- 0.0011 0.8841 +/- 0.0004 3.75 0.9019 +/- 0.0011 0.8987 +/- 0.0004 4.0 0.9132 + 0.0010 0.9140 + 0.0004 4.2 0.9276 + 0.0011 0.9237 +/- 0.0004 4.5 0.9400 +/-'0.0011 0.9388 +/- 0.0004 Based on the GE SxSR fuel assembly.
Appendix 4A, Page 14
Table 4A.3 MCNP4a CALCULATED REACTIVITIES FOR CRITICAL EXPERIMENTS WITH NEUTRON ABSORBERS Ak MCNP4a Worth of Calculated F t Ref. Experiment Absorber kf (eV) 4A.13 PNL-2615 Boral Sheet 0.0139 0.9994+/-0.0012 0.1165 4A.7 B&W-1484 Core XX
- 0.0165 1.0008+/-0.0011 0.1724 4A. 13 PNL-2615 1.62% Boron-steel 0.0165 0.9996+/-0.0012 0.1161 4A.7 B&W-1484 Core XIX 0.0202 0.9961+/-0.0012 0.2103 4A.7 B&W-1484 Core XXI 0.0243 0.9994+/-0.0010 0.1544 4A.7 B&W-1484 Core XVII 0.0519 0.9962+/-0.0012 0.2083 4A. 11 PNL-3602 Boral Sheet 0.0708 0.9941+/-0.0011 0.3135 4A.7 B&W-1484 Core XV 0.0786 0.9910+/-0.0011 0.2092 4A.7 B&W-1484 Core XVI 0.0845 0.9935+/-0.0010 0.1757 4A.7 B&W-1484 Core XIV 0.1575 0.9953+/-0.0011 0.2022 4A.7 B&W-1484 Core XflH 0.1738 1.0020+/-0.0011 0.1988 4A. 14 PNL-7167 iExpt 214R flux trap 0.1931 0.9991 +/-0.0011 0.3722 tEALF is the energy of the average lethargy causing fission.
Appendix 4A, Page 15
Table 4A.4 COMPARISON OF MCNP4a AND KENO5a CALCULATED REACTIVITIESt FOR VARIOUS 1' B LOADINGS Calculated kt , lo 10B, g/cm 2 MCNP4a KENO5a 0.005 1.0381 - 0.0012 1.0340 + 0.0004 0.010 0.9960 +/- 0.0010 0.9941 + 0.0004 0.015 0,9727 - 0.0009 0.9713 - 0.0004 0.020 0.9541 + 0.0012 0.9560 +/- 0.0004 0.025 0.9433 +/- 0.0011 0.9428 +/- 0.0004 0.03 0.9325 + 0.0011 0.9338 +/- 0.0004 0.035 0.9234 +/- 0.0011 0.9251 +/- 0.0004 0.04 0.9173 + 0.0011 0.9179 +/- 0.0004 Based on a 4.5% enriched GE 8xMR fuel assembly.
Appendix 4A, Page 16
Table 4A.5 CALCULATIONS FOR CRMTICAL EXPERIMENTS WITH THICK LEAD AND STEEL REFLECTORSt Separation, Ref. Case E, wt% cm MCNP4a k,f KENOSa kd 4A. 11 Steel 2.35 1.321 0.9980+/-0.0009 0.9992+/-0.0006 Reflector 2.35 2.616 0.99684+/-0.0009 0.9964+/-0.0006 2.35 3.912 0.9974+/-0.0010 0.9980+/-0.0006 2.35 - 0.9962+/-0.0008 0.9939+/-0.0006 4A. 11 Steel 4.306 1.321 0.9997+/-0.0010 1.0012+/-0.0007 Reflector 4.306 2.616 0.9994+/-0.0012 0.9974+/-0.0007 4.306 3.405 0.9969+/-0.0011 0.9951+/-0.0007 4.306 c 0.9910+/-0.0020 0.9947+/-0.0007 4A.12 Lead 4.306 0.55 1.0025+/-0.0011 0.9997+/-0.0007 Reflector 4.306 1.956 1.0000+/-0.0012 0.9985+/-0.0007 4.306 5.405 0.9971*0.0012 0.9946+/-0.0007 t Arranged in order of increasing reflector-fuel spacing.
Appendix 4A, Page 17
Table 4A.6 CALCULATIONS FOR CRITICAL EXPERIMENTS WITH VARIOUS SOLUBLE BORON CONCENTRATIONS Calculated kr Boron Concentration, Reference Experiment ppm MCNP4a KENO5a 4A.15 PNL-4267 0 0.9974 - 0.0012 4A.8 B&W-1645 886 0.9970 +/- 0.0010 0.9924 +/- 0.0006 4A.9 B&W-1810 1337 1.0023 +/- 0.0010 4A.9 B&W-1810 1899 1.0060 - 0.0009 4A.15 PNL-4267 2550 1.0057 +/- 0.0010 -
Appendix 4A, Page 18
Table 4A.7 CALCULATIONS FOR CRITICAL EXPERIMENTS WITH MOX FUEL MCNP4a KENOSa Reference Caset kd EALF" kff EALF" PNL-5S03 MOX Fuel - Exp. No. 21 1.004140.0011 0.9171 1.0046+/-0.0006 0.8868
[4A. 161 MOX Fuel - Exp. No. 43 1.0058+/-0.0012 0.296K 1.0036+/-0.0006 0.2944 MOX Fuel - Exp. No. 13 1.0083+/-0.0011 0.1665 0.9989+/-0.0006 0.1706 MOX Fuel - Exp. No. 32 1.0079+/-0.0011 0.1139 0.9966+/-0.0006 0.1165 WCAP- Saxton @ 0.52' pitch 0.9996+/-0.0011 0.8665 1.0005+/-0.0006 0.8417 3385-54 (4A. 17] Saxton @ 0.56' pitch 1.0036+/-0.0011 0.5289 1.0047+/-0.0006 0.5197 Saxton a 0.56' pitch borated 1.0008+/-0.0010 0.6389 NC NC Saxton @ 0.79' pitch 1.0063 +/-0.0011 0.1520 1.0133+/-0.0006 0.1555 Note: NC stands for not calculated t Arranged in order of increasing lattice spacing.
tt EALF is the energy of the average lethargy causing fission.
Appendix 4A, Page 19
--- - Linear Regression with Correlation Coefficient of 0.13 1.010 I
1.005 0 1.000 4.-
0.995 0.990 Energy of Average Lethargy Causing Fission 1 0.1 (Log Scale)
FIGURE 4A. 1 MCNP CALCULATED k-eff VALUES for VARIOUS VALUES OF THE SPECTRAL INDEX
Linear Regression with Correlation Coefficient of 0.21 1.010-- -
1.005 II.
,.=1.ooo0-- Bi S 0.995 - -- -
0.990 - -
0.985 T7 0.11 Energy of Average Lethargy Causing Fission (Log Scale)
FIGURE 4A.2 KENO5a CALCULATED k-eff VALUES FOR VARIOUS VALUES OF THE SPECTRAL INDEX
- - Linear Regression with Correlation Coefficient of 0.03 1.010 1.005 4-C, U'
- ___ __ _ I_ _ _ --
4-4-
U' 1.000 -~ Ia U,
.4-Bias - - - - - -
U 0
U 0.995 I II'II I I I I I I I 0.990 JI II I i 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 2.0 Enrichment, w/o U-235 FIGURE 4A.3. MCNP CALCULATED k-eff VALUES AT VARIOUS -U-235 ENRICHMENTS
Linear Regression with Correlation Coefficient of 0.38 1.010 1.005 a 1.000
-Bias 00.995 I-- 1 0,
t11 0.990 0.985 3.0 3.5 4.0 4.5 5.0 5.5 6.0 2.0 2.5 Enrichment, w/o U-235 FIGURE 4A.4. KENO CALCULATED k-eff VALUES AT VARIOUS U-235 ENRICHMENTS
0.94 E 0.92 0.90 0.88 C-)
'0-Id 0.86 0.84 -
0.
MCNP k-eff Calculations FIGURE 4A.5 COMPARISON OF MCNP AND KENO5A CALCULATIONS FOR VARIOUS FUEL ENRICHMENTS
(L z
.C-
-ce Reaclivity Calculated wlth KENOSa FIGURE 4A.6. COMPARISON OF MCNP AND KEN05a CALCULATIONS FOR VARIOUS BORON-I0 AREAL DENSITIES
5.0 THERMAL-HYDRAULIC CONSIDERATIONS
5.1 INTRODUCTION
This section provides a summary of the thermal-hydraulic analyses performed to demonstrate compliance of the SFP and its attendant cooling system with the provisions of USNRC Standard Review Plan (SRP) 9.1.3 (Spent Fuel Pool Cooling and Cleanup System, Rev. 1, July 1981) and Section III of the USNRC "OT Position Paper for Review and Acceptance of Spent Fuel Storage and Handling Applications," (April 14, 1978). Similar methods of thermal-hydraulic analysis have been used in the licensing evaluations for other SFP capacity expansion projects.
The thermal-hydraulic qualification analyses for the modified rack array may be broken down into the following categories:
- i. Evaluation of bounding maximum decay heat versus time profiles, used as input to subsequent analyses.
ii. Evaluation of loss-of-forced cooling scenarios, to establish minimum times to perform corrective actions and the associated makeup water requirements.
iii. Determination of the maximum local water temperature, at the instant when the pool decay heat reaches its maximum value, to establish that localized boiling in the Spent Fuel Storage Racks (SFSRs) is not possible while forced cooling is operating. The bulk pool temperature is postulated to be at the maximum limit.
iv. Evaluation of the maximum fuel rod cladding temperature, at the instant when the pool decay heat reaches its maximum value, to establish that nucleate boiling is not possible while forced cooling is operating. The bulk pool temperature is postulated to be at the maximum limit.
The following sections present plant system descriptions, analysis methodologies and assumptions, a synopsis of the input data employed, and summaries of the calculated results.
Report HI-2022867 Holtec Report 5-1 Holtec Project 1196 Holtec HI-2022867 5-1 Hoftec Project 1196
5.2 COOLING SYSTEM DESCRIPTION The Spent Fuel Cooling (SFC) System is designed to maintain the water quality and clarity and to remove the decay heat from the stored fuel in the SFP. It is designed to maintain the SFP water at less than or equal to approximately 1500 F. This is accomplished by recirculating spent fuel coolant water from the SFP through the pumps and coolers and back to the pool. The SFP coolers reject heat to the nuclear intermediate cooling water system, which subsequently rejects its heat to the service water system. The spent fuel coolant pumps take suction from the SFP and deliver the water through the tube side of two coolers arranged in parallel back to the pool.
In addition to its primary function, a bypass purification loop is provided to maintain the purity of the water in the SFP. This loop is also utilized to purify the water in the Borated Water Storage Tank (BWST) following refueling and to maintain clarity in the fuel transfer canal during refueling. Water from the BWST or fuel transfer canal can be purified by using the borated water recirculation pump. The system also provides for filling the fuel transfer canal, the incore instrumentation tank, and the cask loading area from the BWST.
The SFP is provided with a makeup system design, which meets the intent of Safety Guide 13.
That is, the BWST is a Seismic Category 1 vessel; all connecting piping is located in a Seismic Category 1 structure; a backup system for supplying water to the pool is provided through a temporary connection to the Seismic Category 1 service water system; and, there is sufficient time to rig a temporary makeup water supply to the pool in the event of failure of the normal source. The service water system can be supplied from either Lake Dardanelle or the emergency cooling pond.
Holtec Report HI-2022867 5-2 Hottec Project 1196
5.3 SPENT FUEL POOL DECAY HEAT LOADS The decay heat in the SFP is generated in the spent fuel assemblies stored therein. In order to conservatively simplify the decay heat calculations, the total decay heat is considered as coming from two different groups of assemblies:
- i. Fuel assemblies from previous offloads already stored in the SFP ii. Fuel assemblies that are being offloaded from the reactor to the SFP The fuel assemblies in the first group are referred to as previously offloaded fuel. Over the relatively short transient evaluation periods of this report the heat generation rate of these assemblies reduces very slowly with time, due to the exponential nature of radioactive decay and their relatively long decay periods. The decay heat contribution of these assemblies can therefore be conservatively treated as constant, neglecting any reduction in their decay heat contribution during the evaluation period. The fuel assemblies in the second group are referred to as recently offloaded fuel. The heat generation rate of these assemblies reduces rapidly with time, so the decay heat contribution of these assemblies is treated as time varying. The following equation defines the total decay heat generation in the SFP.
QGEN(r)= Qp, + F(T')x Q. (r) (5-1) where:
QGEN(T) is the total time-varying decay heat generation rate in SFP, Btu/hr Qp is the decay heat contribution of the previously offloaded fuel, Btu/hr F(T) is the fraction of the recently offloaded fuel transferred to the SFP QR(T) is the decay heat contribution of the recently offloaded fuel, Btu/hr
,z is the fuel decay time after reactor shutdown, hrs Prior to the start of fuel transfer from the reactor to the SFP, F(T) is equal to zero and the total decay heat in the SFP will be equal to the invariant portion Qp. During the fuel transfer, F(C) will increase linearly from zero to one, and the total decay heat in the SFP will increase to QP+QR(X).
Following the completion of fuel transfer, the total decay heat in the SFP will decrease as QR(r) decreases.
The decay heat contributions of both the previously and recently offloaded fuel are determined using the Holtec QA validated computer program DECOR [5.3.1]. This computer program incorporates the Oak Ridge National Laboratory (ORNL) ORIGEN2 computer code [5.3.2] for Holtec Report HI-2022867 5-3 Holtec Project 1196
performing decay heat calculations. The use of ORIGEN2 code has previously been accepted by the NRC for SFP decay heat calculations on multiple dockets [e.g. USNRC Dockets 50-461 and 50-395].
Based on the input data provided in Tables 5.3.1 and 5.3.2, the fuel decay heat is determined for the following two offload scenarios:
- 1. Partial Core Offload - A refueling batch of 76 assemblies is offloaded from the plant's reactor into the SFP, completely filling all available storage locations. The total SFP inventory prior to the offload is 912 fuel assemblies, for a final post-offload inventory of 988 fuel assemblies. This slightly exceeds the storage capacity of the ANO-1 SFP (and the ANO-1 TS 4.3.3 limit of 968 assemblies) and is used for calculation of decay heat loads, which is conservative.
- 2. Full Core Offload - The full core of 177 assemblies is offloaded from the plant's reactor into the SFP, completely filling all available storage locations. The total SFP inventory prior to the offload is 836 fuel assemblies, for a final post-offload inventory of 1013 fuel assemblies. This slightly exceeds the storage capacity of the ANO-1 SFP (and the ANO-1 TS 4.3.3 limit of 968 assemblies) and is used for calculation of decay heat loads, which is conservative.
There are two types of fuel assemblies to be stored in the SFP: non-high thermal performance and high thermal performance (HTP) assemblies. While most of the differences between these two assembly types are minor from a heat-generation standpoint, the HTP fuel contains 10 kg more uranium that will result in higher decay heat loads. As such, all fuel assemblies discharged from 2007 onward are assumed to be the higher heat generating HTP fuel.
5.4 MINIMUM TIME-TO-BOIL AND MAXIMUM BOILOFF RATE The following conservatisms and assumptions are applied in the time-to-boil and boiloff rate calculations:
- The initial SFP bulk temperature is assumed to be equal to the bulk temperature limit of 150 OF for the full core offload and 120 OF for the partial core offload.
0 The thermal inertia (thermal capacity) of the SFP is based on the net water volume only.
This conservatively neglects the considerable thermal inertia of the fuel assemblies, stainless steel racks and stainless steel SFP liners.
- During the loss of forced cooling evaluations, it is assumed that makeup water is not available. This minimizes the thermal capacity of the SFP as water is boiled off, thus increasing the water level drop rate.
Holtec Report HI-2022867 5-4 Holtec Project 1196
- The loss of forced cooling is assumed to occur coincident with the peak SFP bulk temperature and the maximum pool decay heat. Maximizing the initial temperature and the pool decay heat conservatively minimizes the calculated time-to-boil.
The governing enthalpy balance equation for this condition, subject to these conservative assumptions, can be written as:
C(T) d- = Qg', (" + VO) (5-2) where:
C(t) = Time-varying SFP thermal capacity (BTU/°F)
,T= Time after cooling is lost (hr) x0 = Loss of cooling time after shutdown (hr)
T=Pool water temperature, (OF)
Equation 5-2 is solved to obtain the bulk pool temperature as a function of time, the time-to-boil, boil-off rate and water depth versus time. Once boiling begins, the ongoing evaporation of water will cause the water level of the SFP to decrease. The maximum water boil-off rate is determined by dividing the heat load by the latent heat of water at 212 0F. The time required to drain the SFP to the top of the fuel racks is determined by computing the amount of water above the racks and dividing by the boil-off rate. The major input values for these analyses are summarized in Table 5.4.1.
5.5 MAXIMUM SFP LOCAL WATER TEMPERATURE In order to determine an upper bound on the maximum SFP local water temperature, a series of conservative assumptions are made. The most important of these assumptions are:
- The walls and floor of the SFP are all modeled as adiabatic surfaces, thereby neglecting conduction heat loss through these items. This conservatively maximizes the net heat load, thereby maximizing both global and local temperatures.
Heat losses by thermal radiation and natural convection from the hot SFP surface to the environment are neglected.
No downcomer flow is assumed to exist between the rack modules.
The hydraulic resistance parameters for the rack cells, permeability and inertial resistance, are conservatively adjusted by 10%. The conservatism bounds any small deviations in fuel assembly and rack geometry.
Holtec Report HI-2022867 5-5 Holtec Project 1196
The bottom plenum heights used in the model are less than the actual heights. This ensures that the effects of additional flow restrictions around rack pedestals and bearing pads are bounded in the model.
The hydraulic resistance of every SFSR cell includes the effects of blockage due to an assumed dropped fuel assembly lying horizontally on top of the SFSRs. This conservatively increases the total rack cell hydraulic resistance and bounds the thermal-hydraulic effects of a fuel assembly dropped anywhere in the spent fuel storage area.
The objective of this study is to demonstrate that the thermal-hydraulic criterion of ensuring local subcooled conditions in the SFP is met for all postulated fuel offload scenarios. The local thermal-hydraulic analysis is performed such that slight fuel assembly variations are bounded.
An outline of the Computational Fluid Dynamics (CFD) approach is described in the following.
There are several significant geometric and thermal-hydraulic features of the ANO-1 SFP that need to be considered for a rigorous CFD analysis. From a fluid flow modeling standpoint, there are two regions to be considered. One region is the SFP bulk region where the classical Navier-Stokes equations [5.5.11 are solved, with turbulence effects included. The other region is the SFSRs containing heat generating fuel assemblies, located near the bottom of the SFP. In this region, water flow is directed vertically upwards due to buoyancy forces through relatively small flow channels formed by the B&W 15x15 fuel assemblies in each SFSR cell. This situation is modeled as a porous region with pressure drop in the flowing fluid governed by Darcy's Law as:
oaP - i- V Vi (5-3)
DX1 K(i) 2 where DP/aX; is the pressure gradient, K(i), V, and C are the corresponding permeability, velocity and inertial resistance parameters, p is the fluid density, and gi is the fluid viscosity. These terms are added as sink terms to the classic Navier-Stokes equations. The permeability and inertial resistance parameters for the rack cells loaded with B&W 15x15 fuel assemblies are determined based on friction factor correlations for the laminar flow conditions that would exist due to the low buoyancy induced velocities and the small size of the flow channels.
The ANO-1 SFP geometry requires an adequate portrayal of both large scale and small scale features, spatially distributed heat sources in the SFSRs and water inlet/outlet piping. Relatively cooler bulk water normally flows down between the perimeter of the fuel rack array and wall Holtec Report HI-2022867 5-6 Holtec Project 1196
liner, a clearance known as the downcomer. Near the bottom of the racks the flow turns from a vertical to horizontal direction into the bottom plenum, supplying cooling water to the rack cells.
Heated water flowing out of the top of the racks mixes with the bulk water. An adequate modeling of these features in the CFD program involves meshing the large scale bulk SFP region and small scale downcomer and bottom plenum regions with sufficient number of computational cells to capture both the global and local features of the flow field.
The distributed heat sources in the SFP racks are modeled by identifying distinct heat generation zones considering recently offloaded fuel, bounding peaking effects, and the presence of background decay heat from previous offloads. Two heat generating zones are modeled. The first consists of background fuel from previous offloads. The second zone consists of fuel from recently offloaded fuel assemblies. This is a conservative model, since all of the hot fuel assemblies from the recent offload are placed in a contiguous area. A uniformly distributed heat generation rate was applied throughout each distinct zone (i.e., there were no variations in heat generation rate within a single zone).
The CFD analysis was performed on the commercially available FLUENT [5.5.2] Computational Fluid Dynamics program, which has been benchmarked under Holtec's QA program. The FLUENT code enables buoyancy flow and turbulence effects to be included in the CFD analysis. Buoyancy forces are included by specifying a temperature-dependent density for water and applying an appropriate gravity vector. Turbulence effects are modeled by relating time-varying Reynolds' Stresses to the mean bulk flow quantities with the standard k-e turbulence model.
Some of the major input values for this analysis are summarized in Table 5.5.1. An isometric view of the assembled CFD model is presented in Figure 5.5.1.
5.6 FUEL ROD CLADDING TEMPERATURE The maximum fuel rod cladding temperature is determined to establish that nucleate boiling is not possible while forced cooling is operating. This requires demonstrating that the highest fuel rod cladding temperatures are less than the local saturation temperature of the adjacent SFP water. The maximum fuel cladding superheat above the local water temperature is calculated for two different peak fuel rod heat emission rates.
Holtec Report HI-2022867 5-7 Holtec Project 1196
A fuel rod can produce F, times the average heat emission rate over a small length, where Fz is the axial peaking factor. The axial heat distribution in a rod is generally a maximum in the central region, and tapers off at its two extremities. Thus, peak cladding heat flux over an infinitesimal rod section is given by the equation:
QxFZ qc- A, (5-4) where Q is the rod average heat emission and A&is the total cladding external heat transfer area in the active fuel length region. The axial peaking factor is given in Table 5.5.1.
As described previously, the maximum local water temperature was computed. Within each fuel assembly sub-channel, water is continuously heated by the cladding as it moves axially upwards under laminar flow conditions. Rohsenow and Hartnett [5.6.1] report a Nusselt-number for laminar flow heat transfer in a heated channel. The film temperature driving force (ATf) at the peak cladding flux location is calculated as follows:
AD- =q.c hf (5-5) hf = NuKw Dh where hf is the waterside film heat transfer coefficient, Dh is sub-channel hydraulic diameter, Kw is water thermal conductivity and Nu is the Nusselt number for laminar flow heat transfer.
In order to introduce some additional conservatism in the analysis, we assume that the fuel cladding has a crud deposit resistance R: (equal to 0.0005 ft2-hr-°R/Btu) that covers the entire surface. Thus, including the temperature drop across the crud resistance, the cladding to water local temperature difference (ATr) is given by the equation AT, = ATf + Rc x q,.
H1-2022867 Report HI-2022867 Holtec Report 5-8 Holtec Project 1196 Holtec 5-8 Holtec Project 1196
5.7 RESULTS This section contains results from the analyses performed for the postulated offload scenarios.
5.7.1 Decay Heat For the offload scenarios described in Section 5.3, the calculated SFP decay heat loads are summarized in Table 5.7.1. Given the conservatisms incorporated into the calculations, actual decay heat loads will be lower than these calculated values. Figures 5.7.1 and 5.7.2 each present profiles of net decay heat load versus time for the evaluated transient scenarios.
5.7.2 Minimum Time-to-Boil and Maximum Boiloff Rate For the offload/cooling described in Section 5.4, the calculated times-to-boil and maximum boil-off rates are summarized in Table 5.7.2. These results show that, in the extremely unlikely event of a failure of forced cooling to the SFP, there would be at least 3.18 hours2.083333e-4 days <br />0.005 hours <br />2.97619e-5 weeks <br />6.849e-6 months <br /> available for corrective actions prior to SFP boiling. Given the conservatisms incorporated into the calculations, actual times-to-boil will be higher than these calculated values. It is noted that a complete failure of forced cooling is extremely unlikely. The maximum water boiloff rate is less than 87 gpm.
5.7.3 Local Water and Fuel Cladding Temperatures Consistent with our approach to make conservative assessments of temperature, the local water temperature calculations described in Section 5.5 are performed for a SFP with a total decay heat generation equal to the calculated decay heat load coincident with the maximum SFP bulk temperature. Thus, the local water temperature evaluation is a calculation of the temperature increment over the theoretical spatially uniform value due to local hot spots (due to the presence of highly heat emissive fuel assemblies). As described in Subsection 5.6, the peak fuel clad superheats (i.e., the maximum clad-to-local water temperature difference) are determined. The resultant bounding superheat values were used to calculate bounding maximum fuel clad temperatures.
Holtec Report HI-2022867 5-9 Holtec Project 1196
The numeric results of the maximum local water temperature and the bounding fuel cladding temperature evaluations are presented in Table 5.7.3. Figure 5.7.3 presents converged temperature contours in a vertical slice through the hot fuel region. Figure 5.7.4 presents converged velocity vectors in a vertical slice through the hot fuel region.
Both the maximum local water temperatures and the bounding fuel cladding temperatures are substantially lower than the 240°F local boiling temperature at the top of the SFSRs. These results demonstrate that boiling, including nucleate boiling on clad surfaces, cannot occur anywhere within the ANO-1 SFP.
Under a postulated accident scenario of the loss of all cooling, the water temperature will rise.
Assuming a temperature of 2121F at the inlet to the rack cells, and conservatively using the bounding bulk-to-local and local-to-clad temperature differences from Table 5.7.3, the maximum possible cladding temperature will be 261.51F, which is greater than the saturation temperature at the top of the active fuel length. Due to the low maximum assembly heat flux (approximately 7300 W/m 2) and the critical heat flux required for departure from nucleate boiling (on the order of 106 W/m2 ), it can be concluded that the fuel cladding will not be subjected to departure from nucleate boiling even under the postulated accident scenario of the loss of all SFP cooling and the cladding integrity would be maintained.
5.8 REFERENCES
[5.3.11 "QA Documentation for DECOR," Holtec Report HI-971734, Revision 0.
[5.3.2] A.G. Croff, "ORIGEN2 - A Revised and Updated Version of the Oak Ridge Isotope Generation and Depletion Code," ORNL-5621, Oak Ridge National Laboratory, 1980.
[5.5.1] Batchelor, G.K., "An Introduction to Fluid Dynamics," Cambridge University Press, 1967.
[5.5.2] "Validation of FLUENT Version 5.1," Holtec Report HI-992276, Revision 0.
[5.6.1] Rohsenow, N.M., and Hartnett, J.P., "Handbook of Heat Transfer," McGraw Hill Book Company, New York, 1973.
HI-2022867 Report HI-2022867 Holtec Report 5-10 Holtec Project 1196 Holtec 5-10 Holtec Project 1196
Table 5.3.1 Key Input Data for Decay Heat Computations Input Data Parameter Value Reactor Thermal Power (MWt) 2800 Number of Assemblies in Reactor Core 177 Maximum Number of Storage Cells in SFP 968 Bounding Discharge Schedule Table 5.3.2 Minimum In-Core Hold Time (hr) 100 Fuel Discharge Rate 5 per hour Holtec Report HI-2022867 5-11 Holtec Project 1196
Table 5.3.2 Offload Schedule Cycle Offload Date Number of Average Initial 235 U Assembly U Number (mmlddlyyyy) Assemblies Burnup Enrichment Weight (kgU)
(MWd/MTU) (wt.%)(4) 1 01/01/2002(1) 76 75,000 4.00 487 2 01/01/2004 76 75,000 4.00 487 3 01/01/2006 76 75,000 4.00 487 4 01/01/2008 76 75,000 4.00 497 5 01/01/2010 76 75,000 4.00 497 6 01/01/2012 76 75,000 4.00 497 7 01/01/2014 76 75,000 4.00 497 8 01/01/2016 76 75,000 4.00 497 9 01/01/2018 76 75,000 4.00 497 10 01/01/2020 76 75,000 4.00 497 11 01/01/2022 76 75,000 4.00 497 12 01/01/2024 76 or 177(2) 75,000 4.00 497 13 01/01/2026 76 or 0(3) 75,000 4.00 497 Table Notes:
(1) Dates are arbitrarily set to yield two years between offloads. While historic (ca. 2002) offloads were on 18-month cycles, the use of the longer 24-month cycle will have a negligible impact on the total SFP heat load. This is due to the use of bounding bumups and initial enrichments for the historic offloads, as well as the extremely long cooling times for these fuel assemblies at the point in time where the SFP becomes filled.
(2) 76 assemblies for partial core offload (previously discharged fuel), 177 assemblies for full core offload (recently discharged fuel).
(3) 76 assemblies for partial core offiload (recently discharged fuel), 0 assemblies for full core offload.
(4) Initial enrichments may be as high as 5.0 wt.%. For a given bumup, a lower enrichment will yield a higher calculated decay heat. Thus, the use of 4.0 wt.% is conservative for the purposes of the thermal analysis.
Holtec Report HI-2022867 5-12 Holtec Project 1196
Table 5.4.1 Key Input Data for Time-To-Boil Evaluation SFP Surface Area 1012 ft2 Minimum Pool Water Depth 37.0 feet SFP Net Water Volume 34,340 ft3 Note: The net water volume is the gross water volume (i.e., area times depth) minus the volume displaced by the fuel racks and stored fuel assemblies.
HI-2022867 5-13 Holtec Project 1196 Report HI-2022867 Holtec Report 5-13 Holtec Project 1196
Table 5.5.1 Key Input Data for Local Temperature Evaluation Axial Peaking Factor 1.65 Number of Fuel Assemblies 968 Cooled SFP Water Flow Rate 1000 gpm*
through SFC Heat Exchanger Fuel Assembly Type B&W 15xl 5 Fuel Rod Outer Diameter 0.430 inches Active Fuel Length"* 140.6 inches Number of Rods per Assembly 208 rods Rack Cell Inner Dimension 8.97 inches Rack Cell Length 162 inches Modeled Bottom Plenum Height 3 inches
- Conservatively, only one pump flow is credited in the analysis.
- Conservatively, the lowerbound value for the active fuel length for ANO-1 fuel assemblies is used in the analysis.
Holtec Report HI-2022867 5-14 Holtec Project 1196
Table 5.7.1 Result of SFP Decay Heat Calculations Heat Load Component Partial Core Offload Value Full Core Offload Value (Btulhr) (Btulhr)
Previously Discharged Fuel 6.0641 06 5.766x1 06 Recently Discharged Fuel at 15.760x10 6 34.400x10 6 End of Transfer Total Bounding Decay Heat 21.824x10 6 40.1661 06 SFP Pump Heat (2 operating) 0.204x10 6 0.204x10 6 Total Bounding SFP Heat 22.028x106 40.370x10 6 1-2022867 5-15 Holtec Project 1196 Holtec Report H Holtec Report HI-2022867 5-15 Holtec Project 1196
Table 5.7.2 Results of Loss-of-Forced Cooling Evaluations Calculate Result Parameter Partial Core Full Core Offload Value Offload Value Minimum Time-to-Boil 8.67 hours7.75463e-4 days <br />0.0186 hours <br />1.107804e-4 weeks <br />2.54935e-5 months <br /> 3.18 hours2.083333e-4 days <br />0.005 hours <br />2.97619e-5 weeks <br />6.849e-6 months <br /> Maximum Boiloff Rate 46.88 gallons per minute 86.28 gallons per minute Minimum Time for Water to 62.1 hours1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> 33.7 hours8.101852e-5 days <br />0.00194 hours <br />1.157407e-5 weeks <br />2.6635e-6 months <br /> Drop to Top of Racks Report H1-2022867 5-16 Holtec Project 1196 Holtec Report HI-2022867 5-16 Holtec Project 1196
Table 5.7.3 Results of Maximum Local Water and Fuel Cladding Temperature Evaluations Parameter Value Peak Local Water Temperature 168 0 F Peak Cladding Superheat 31.5 0F Peak Local Fuel Cladding Temperature 199.50 F Holtec Report HI-2022867 5-17 Holtec Project 1196
Feb 15, 2002 Grid FLUENT 5.1 (3d, segregated, ke)
Figure 5.5.1 Schematic of the CFD Model of the ANO-1 SFP.
5-18 Holtec Project 1196 Holtec Report HI-2022867
Figure 5.7.1 - Partial Core Offload Bounding Spent Fuel Pool Heat Load (including previously and recently discharged fuel and 2 SFP pumps) 2.30E+07 2.1012+07 1.90E+07 VC1.70E+07 I
0 1.0E0 S1.30E+07 (0 .IOE+07 7.0012+06 7.OOE+06 0 40 80 120 160 200 240 280 320 360 400 440 480 Time After Reactor Shutdown (hr) 1-2022867 5-19 Hoitec Project 1196 Holtec Report H Hoitec HI-2022867 5-19 Holtec Project 1196
Figure 5.7.2 - Full Core Offload Bounding Spent Fuel Pool Heat Load (including previously and recently discharged fuel and 2 SFP pumps) 4.50E+07 4.OOE+07 3.50E+07 3.OOE+07 0 2.50E+07 a.2.OOE+07 LL 1.50E+07 I.OOE+07 5.OOE+06 0 40 80 120 160 200 240 280 320 360 400 440 480 Time After Reactor Shutdown (hr) 5-20 1-loltec Project 11 9~3 Holtec Report H Holtee 1-2022867 HI-2022867 5-20 Holtec Proje 1196
1.68e+02 1.61e+02 1.54e+02 1.48e+02 1.41e+02 1.34e+02 1.27e+02 1.21e+02 1.14e+02 1.07e+02 x
1.00e+02 Contours of Static Temperature (f) Jan 26, 2006 FLUENT 5.5 (3d, dp, segregated, ke)
Figure 5.7.3. Contours of Static Temperature In a Vertical Plane Through the Center of the SFP. FLUENT dp, (3d, 26, ke) 2006 segregated, Jan 5.5 Report H Holtec Report Holtec 1-2022867 HI-2022867 5-21 5-21 Holtec Project 1196 Holtec Project 1196
1.06e+00 9.50e-01 8.45e-01 7.40e-01 6.34e-01 5.29e-01 4.23e-01 3.18e-01 2.12e-01 1.07e-01 x -
1.41e-03 Colored By Velocity Magnitude (ftls) Jan 26, 2006 Velocity Vectors FLUENT 5.5 (3d, dp, segregated, ke)
Figure 5.7.4: Velocity Vector Plot In a Vertical Plane Through the Center of the SFP.
Holtec Report HI-2022867 5-22 Holtec Project 1196
6.0 MECHANICAL ACCIDENTS
6.1 INTRODUCTION
The USNRC OT position paper [6.1.1] specifies that the design of the rack must ensure the functional integrity of the spent fuel racks under all credible drop events.
The postulated fuel drop events on the ANO-1 SFP Region 3 racks, which will be inserted with Metamic material in the rack flux traps with lead-ins installed on the top of flux traps, were evaluated. The principal effect of this postulated drop accident would be damages to the poison material in the Region 3 racks, which would increase reactivity in those storage racks. In this report, the Region 1 racks have been analyzed for criticality safety under the assumption that they do not contain any poison material. The Region 2 racks in the ANO-1 SFP do not contain any poison material. Therefore, the reactivity effects of the postulated fuel drop accident for the Region 3 racks are bounding.
6.2 DESCRIPTION
OF MECHANICAL ACCIDENTS The postulated drop accidents assume that a fuel assembly, along with a portion of the handling tool, will drop vertically and hit the top of the rack at one of two enveloping locations: the cell wall edge or the cell wall corner intersection.
6.3 EVALUATION OF MECHANICAL ACCIDENTS To obtain conservative results, the postulated mechanical drop accidents were evaluated based on the maximum impact energy, a thinner rack wall thickness, weakest weld size and configuration, and worst case fabrication tolerance for the ANO-1 Region 3 racks. The evaluation of the postulated drop events demonstrated that, with the previously described conservative considerations, the postulated mechanical drop accidents would result in significant damage to the impacted cell wall down into the active fuel region of the racks, leading to the failure of Metamic inserts inside the flux trap.
Report H 1-2022867 6-I Holtec Project 1196 Holtec Report Holtec HI-2022867 6-1 Hoftec Project 1196
6.4 CONCLUSION
The fuel assembly drop events postulated for the ANO-1 spent fuel pool Region 3 racks were conservatively evaluated and found that the poison inserts, as well as the cell wall, of the impacted rack cell could be significantly damaged under the postulated accidental events. To ensure the functional integrity of the rack, the criticality safety evaluation (reported in Section 4.0) conservatively analyzed the Region 3 racks under the postulated assumption that all poison inserts are damaged. The racks were determined to remain subcritical even under this extremely conservative postulated scenario, when credit was taken for a conservative value of 1600 ppm soluble boron in the pool. The minimum technical specification requirement for soluble boron concentration in the pool water is greater than 2000 ppm.
6.5 REFERENCES
[6.1.1] "OT Position for Review and Acceptance of Spent Fuel Storage and Handling Applications," dated April 14, 1978, and addendum dated 1979.
6-2 Holtec Project 1196 Report HI-2022867 Holtec Report 1-loltec HI-2022867 6-2 Holtec Project 1196