LR-N06-0166, 2005 Annual Radioactive Effluent Release Report for Salem and Hope Creek Generating Stations

From kanterella
(Redirected from ML061290341)
Jump to navigation Jump to search
2005 Annual Radioactive Effluent Release Report for Salem and Hope Creek Generating Stations
ML061290341
Person / Time
Site: Salem, Hope Creek  PSEG icon.png
Issue date: 05/01/2006
From:
Public Service Enterprise Group
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
FOIA/PA-2010-0209, HCGS RERR-28, LR-N06-0166, SGS RERR-54
Download: ML061290341 (187)


Text

PSEG NUCLEAR LLC 2005 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT FOR THE SALEM AND HOPE CREEK GENERATING STATIONS SGS RERR-54 DOCKET NO. 50-272 DOCKET NO. 50-311 OPERATING LICENSE NO. DPR-070 OPERATING LICENSE NO. DPR-075 HCGS RERR-28 DOCKET NO. 50-354 OPERATING LICENSE NO. NPF-057 May 2006

2005 SGS AND HCGS RADIOACTIVE EFFLUENTS RELEASE REPORT 1

2005 SGS AND HCGS RADIOACTIVE EFFLUENTS RELEASE REPORT SALEM AND HOPE CREEK GENERATING STATIONS RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY-DECEMBER 2005 Table of Contents INTRODUCTION PART A. PRELIMINARY SUPPLEMENTAL INFORMATION 1.0 REGULATORY LIMITS

-4

-5 5

1.1 Fission and Activation Gas Release Limits 1.2 lodines, Particulates, and Tritium 1.3 Liquid Effluents Release Limits A5 5

6 1.4 Total Dose Limit 2.0 MAXIMUM PEI 6

OMISSIBLE CONCENTRATIONS (MPC) 6 3.0 AVERAGE ENERGY 4.0 MEASUREMENTS AND APPROXIMATIONS OF TOTAL RADIOACTIVITY 4.1 Liquid Effluents 4.2 Gaseous Effluents l

4.3 Estimated Total Error__

5.0 BATCH RELEASES 1

6.0 UNPLANNED RELEASES 1

7.0 ELEVATED RADIATION MONITOR RESPONSES 1

8.0 MODIFICATION TO PREVIOUS RADIOACTIVE EFFLUENT RELEASE REPORTS 1

PART B. GASEOUS EFFLUENTS 11 PART C. LIQUID EFFLUENTS 11 7

7 7

8 9

0 0

0 a

D D

2

2005 SGS AND HCGS RADIOACTIVE EFFLUENTS RELEASE REPORT PART D. SOLID WASTE 10 PART E. RADIOLOGICAL IMPACT ON MAN 11 Liquid Pathways 11 l

Air Pathways 12 Direct Radiation 12 L

Total Dose 13 K

Assessment 14 Trends 15 PART F. METEOROLOGICAL DATA 17 PART G. OFFSITE DOSE CALCULATION MANUAL CHANGES 17 PART H. INOPERABLE MONITORS 19 L

PART I. PROCESS CONTROL PROGRAM (PCP) CHANGES 20 PART J. ENVIRONMENTAL MONITORING LOCATION CHANGES 20 TABLE 1B - GASEOUS EFFLUENTS - ELEVATED RELEASES 27 D

TABLE 1C GASEOUS EFFLUENTS - GROUND LEVEL RELEASES 28 TABLE 2B - LIQUID EFFLUENTS 40 TABLE 3A - SOLID WASTE AND IRRADIATED SHIPMENTS - SALEM 48 U

TABLE 3B - SOLID WASTE AND IRRADIATED FUEL SHIPMENTS -

HC 51 0

TABLE 4A -

SUMMARY

SHEET FOR RADIOACTIVE EFFLUENTS RELEASED IN A BATCH MODE - GASEOUS 53 TABLE 4B -

SUMMARY

SHEET FOR RADIOACTIVE EFFLUENTS RELEASED IN BATCH MODE - LIQUID 59 0

APPENDIX A - METEOROLOGICAL DATA APPENDIX B - MPC DATA L

APPENDIX C - Salem ODCM U

3 L

2005 SGS AND HCGS RADIOACTIVE EFFLUENTS RELEASE REPORT SALEM AND HOPE CREEK GENERATING STATIONS RADIOACTIVE EFFLUENT RELEASE REPORT: JANUARY - DECEMBER 2005 INTRODUCTION This report, SGS-RERR-54/HCGS-RERR-28 summarizes information pertaining to the releases of radioactive materials in liquid, gaseous and solid form from the Salem (SGS) and Hope Creek Generating (HCGS) Stations for the period January 1, 2005 to December 31, 2005.

Salem Unit 1 is a Westinghouse Pressurized Water Reactor that has a licensed core thermal power of 3459 MWt and an approximate net electrical output of 1177 MWe.

Salem Unit 1 achieved initial criticality on December 11, 1976 and went into commercial operation on June 30, 1977.

Salem Unit 2 is a Westinghouse Pressurized Water Reactor that has a licensed core thermal power of 3459 MWt and an approximate net electrical output of 1134 MWe.

Salem Unit 2 achieved initial criticality on August 2, 1980 and went into commercial operation on October 13, 1981.

The Hope Creek Generating Station (HCGS) is a General Electric (GE) Boiling Water Reactor designed to operate at a rated core thermal power of 3339 MWt and an approximate net electrical output of 1139 MWe. The HCGS achieved initial criticality on June 28, 1986 and went into commercial operation on December 20, 1986.

This report is prepared in the format of Regulatory Guide 1.21, Appendix B, as required by Control 6.9.1.8 of the Salem Units 1 and 2 Offsite Dose Calculation Manual (ODCM) and Control 6.9.1.7 of the Hope Creek ODCM. Our responses to parts A-F of the "Supplemental Information" section of Regulatory Guide 1.21, Appendix B, are included in the following pages.

As required by Regulatory Guide 1.21, the Offsite Dose Calculation Manual limits are described in detail within this report along with a summary description of how total radioactivity measurements and their approximations were developed.

To facilitate determination of compliance with 40CFR190 requirements, the following information on electrical output is provided.

Salem Unit 1 generated 9440577 megawatt-hours of electrical energy (net) during the reporting period.

Salem Unit 2 generated 8886027 megawatt-hours of electrical energy (net) during the reporting period.

Hope Creek generated 7684767 megawatt-hours of electrical energy (net) during the reporting period.

4

W 2005 SGS AND HCGS RADIOACTIVE EFFLUENTS RELEASE REPORT PART A. PRELIMINARY SUPPLEMENTAL INFORMATION 1.0 REGULATORY LIMITS 1.1 Fission and Activation Gas Release Limits awu The dose rate due to radioactive materials released in gaseous effluents from the site (i.e.

Salem Units 1 & 2, and Hope Creek) to areas at and beyond the site boundary, shall be limited to the following:

For noble gases: Less than or equal to 500 mrem/yr to the total body and L

less than or equal to 3000 mrem/yr to the skin.

In addition, the air dose due to noble gases released in gaseous effluents from each l

reactor unit (i.e. Salem Unit 1, Unit 2, or Hope Creek) to areas at and beyond the site boundary, shall be limited to the following:

During any calendar quarter: Less than or equal to 5 mrad for gamma L

radiation and less than or equal to 10 mrad for beta radiation and, During any calendar year: Less than or equal to 10 mrad for gamma L

radiation and less than or equal to 20 mrad for beta radiation.

1.2 lodines, Particulates, and Tritium U

The dose rate due to radioactive materials released in gaseous effluents from the site to areas at and beyond the site boundary, shall be limited to the following:

For iodine-13 1, iodine-133, tritium and all radionuclides in particulate form with half-lives greater than 8 days: Less than or equal to 1500 mrem/yr to any organ.

L In addition, the dose to a member of the public from iodine-13 1, iodine-133, tritium, and all radionuclides in particulate form with half-lives greater than 8 days in gaseous effluents released, from each reactor unit, to areas at and beyond the site boundary, shall be limited to U

the following:

During any calendar quarter: Less than or equal to 7.5 mrem to any organ and,L Durng any calendar year: Less than or equal to 15 mrem to any organ.

L L

5 L

2005 SGS AND HCGS RADIOACTIVE EFFLUENTS RELEASE REPORT 1.3 Liquid Effluents Release Limits The concentration of radioactive material released in liquid effluents to unrestricted areas shall be limited to the concentrations specified in 10CFR2O, Appendix B, Table II, Column 2 for radionuclides other than dissolved or entrained noble gases. For dissolved or entrained noble gases, the concentration shall be limited to 2E-04 microcuries per milliliter.

In addition, the dose or dose commitment to a member of the public from radioactive materials in liquid effluents released to unrestricted areas shall be limited to:

During any calendar quarter: Less than or equal to 1.5 mrem to the total body, and less than or equal to 5 mrem to any organ, and During any calendar year: Less than or equal to 3 mrem to the total body, and less than or equal to 10 mrem to any organ.

1.4 Total Dose Limit The annual (calendar year) dose or dose commitment to any member of the public, due to releases of radioactivity and radiation; from uranium fuel cycle sources shall be limited to less than or equal to 25 mrem to the total body or any organ (except the thyroid, which shall be limited to less than or equal to 75 mrem).

2.0 MAXIMUM PERMISSIBLE CONCENTRATIONS (MPC)

Regulatory Guide 1.21 requires that the licensee provide the MPC's used in determining allowable release rates or concentrations for radioactive releases.

a. MPC values are not used for gaseous releases. Determination of maximum release rates for noble gases, Iodine-13 1, Iodine-133, tritium, and for all radionuclides in particulate form (with half-lives > 8 days),

are based on dose rate calculations as specified in the ODCM.

b. According to current Technical Specifications, MPC values as stated in 10CFR20, Appendix B, Table II, Column 2 are to be used for liquid effluents. Since the MPC values were removed from 10CFR20 effective 1/1/94, the MPC values are now contained in the ODCM. These MPC values are added as Appendix B of this report.

I

c. The MPC value used for dissolved or entrained noble gases in liquid effluents is 2E-04 microcuries per milliliter.

6

2005 SGS AND HCGS RADIOACTIVE EFFLUENTS RELEASE REPORT 3.0 AVERAGE ENERGY Regulatory Guide 1.21 requires that the licensee provide the average energy of the radionuclide mixture in releases of fission and activation gases, if applicable. Release limits for SGS or HCGS are not based upon average energy. Therefore this section is not applicable to SGS or HCGS.

4.0 MEASUREMENTS AND APPROXIMATIONS OF TOTAL RADIOACTIVITY 4.1 Liquid Effluents 1

Liquid effluents are monitored in accordance with Table 4.11-1 of the Salem ODCM and Table 4.11.1.1.1-1 of the Hope Creek ODCM.

During the period of record, all batch liquid wastes were routed to the sampling tanks l

for monitoring prior to release. The ODCM requires these tanks to be uniformly mixed for sampling and analysis before being released.

Batch releases are defined as:

  • For Hope Creek, releases from the Equipment Sample Tanks, Floor Drain Sample tanks, Detergent Drain Tanks, and the Condensate Storage Tank.
  • For Salem, FRAC Tank releases from the Groundwater Remediation Project, releases from the Service Water Drums which are collected and disposed via the Non-Radwaste Basin, Waste Monitor Holdup Tanks and the Chemical Volume Control System (CVCS) Monitor Tanks. During the period of record, all batch liquid wastes from the Chemical Drain Tank and Laundry and Hot Shower Tanks C

were routed to Waste Monitor Holdup Tanks for monitoring prior to release. For process flexibility of liquid effluents, the Salem Unit 1 and 2 Liquid Radwaste System is cross-connected.

L Continuous releases are defined as:

  • For Hope Creek, a continuous liquid effluent release path exists through the U

Circulating Water Dewatering Sump Discharge.

  • For Salem, continuous liquid release pathways include condensate releases for intermittent blow-down of the Steam Generators, and through the Chemical Waste Basin.

Representative samples were obtained in accordance with Table 4.11-1 of the Salem 0

ODCM for the Salem Generating Stations and Table 4.11.1.1.1 -1 of the Hope Creek ODCM for Hope Creek Generating Station. Specific activities from the analyses.

were multiplied by the volume of effluent discharged to the environment in order to U

determine the total liquid activity discharged.

The detection requirements of Table 4.11-1 (SGS) and Table 4.1 1.1.1.1-1 (HCGS) of the ODCM are achieved. Radionuclides measured at concentrations below the ODCM detection limit (LLD) are treated as being present. Radionuclides for which no activity was detected while meeting the required LLD's are treated as absent.

7 L

2005 SGS AND HCGS RADIOACTIVE EFFLUENTS RELEASE REPORT 4.2 Gaseous Effluents Salem Units 1 and 2:

Gaseous effluent streams at SGS are monitored and sampled in accordance with Table 4.11-2 of the ODCM. The Plant Vent is the final release point for planned gaseous effluent releases and is continuously monitored by installed radiation monitors. The vent is also continuously sampled for iodine and particulates with a charcoal cartridge and filter paper. The filter and charcoal are normally changed weekly, and analyzed on a multi-channel analyzer.

Sampling is also performed on all gas decay tanks and the containment atmosphere prior to release to the environment. The plant vent is normally sampled weekly for noble gases, particulates, iodines and tritium.

The detection requirements of Table 4.11-2 of the ODCM are achieved or exceeded.

Radionuclides detected at concentrations below the ODCM LLD are treated as being present. Radionuclides for which no activity was detected while meeting the required LLDs are treated as absent.

Continuous Mode gaseous releases are quantified by routine sampling and isotopic analyses of the plant vent, as required by the ODCM. Specific activities for each isotope detected are multiplied by the total vent flow volume for the entire sampling period in order to determine the normal continuous release of radioactivity through the plant vent.

Batch Mode noble gas releases are quantified by sampling each decay tank or containment atmosphere prior to release. Specific activities for each isotope are multiplied by the total volume of gas discharged for that batch to determine the total activity released.

Elevated plant vent radiation monitoring system readings while the channel is in an alarm state are treated as batch mode releases. If specific activity data from grab samples are not available, then the release is quantified by the use of the plant vent radiation monitors. The monitor response is converted to "specific activity" using historical efficiency factors. The "specific activity" is multiplied by the volume of effluent discharged while the channel was in an alarm state in order to determine the total activity discharged.

8

2005 SGS AND HCGS RADIOACTIVE EFFLUENTS RELEASE REPORT Hope Creek:

Gaseous effluent streams at HCGS are monitored and sampled in accordance with Table 4.11.2.1.2-1 of the ODCM. The North Plant Vent (NPV) and South Plant Vent (SPV) are the final release points for most planned gaseous effluent releases. The NPV and SPV are continuously monitored for iodine, particulates and noble gases. These monitors have moving particulate and fixed charcoal filters. The particulate filters and charcoal cartridges are normally replaced and analyzed weekly. These analyses are performed on a multichannel analyzer. The NPV and SPV are also normally sampled weekly for noble gases and tritium.

A small quantity of gaseous effluent is released via the Filtration, Recirculation, and Ventilation System (FRVS) vent during FRVS testing periods. The FRVS is continuously monitored for noble gases when in service, and has fixed particulate and L

charcoal filters. When the system is in vent mode for greater than two hours, samples are collected at the end of the release period. During periods of extended runs, samples are normally taken weekly.

The detection requirements of Tables 4.11.2.1.2-1 of the ODCM are achieved or exceeded. Radionuclides detected at concentrations below the ODCM detection limit (LLD) are treated as being present. Radionuclides for which no activity was detected while meeting the required LLDs are treated as absent.

u Batch Mode noble gas releases (i.e. primary containment purge) are quantified by pre-release sampling and isotopic analysis. In order to estimate the total radioactivity released, specific activities for each isotope are multiplied by the containment volume.

43 Estimated Total Error

[

The estimated total error of reported liquid and solid releases is within 25%.

The estimated total error of the reported continuous gaseous releases is within 50%

when concentrations exceed detectable levels. This error is primarily due to variability of waste stream flow rates and changes in isotopic distributions of waste streams between sampling periods. The estimated total error of the reported batch gaseous releases is within 10%.

Error estimates for releases where sample activity is below the detectable concentration L

levels are not included since error estimates at the LLD are not defined.

9

2005 SGS AND HCGS RADIOACTIVE EFFLUENTS RELEASE REPORT 5.0 BATCH RELEASES Summaries of batch releases of gaseous and liquid effluents are provided in Tables 4A and 4B.

6.0 UNPLANNED RELEASES During this reporting period, no unplanned releases occurred.

7.0 ELEVATED RADIATION MONITOR RESPONSES During this reporting period, no elevated Effluent Radiation Monitor response occurred.

8.0 MODIFICATION TO PREVIOUS RADIOACTIVE EFFLUENT RELEASE REPORTS There were no modifications to the previous Radioactive Effluent Release Reports.

PART B. GASEOUS EFFLUENTS See Summary Tables IA through IC.

PART C. LIQUID EFFLUENTS See Summary Tables 2A through 2B.

PART D. SOLID WASTE See Summary in Table 3.

10

2005 SGS AND HCGS RADIOACTIVE EFFLUENTS RELEASE REPORT If I I

PART E. RADIOLOGICAL IMPACT ON MAN The calculated individual doses in this section are based on the controlling dose pathways and age groups as described below. The estimated dose represents the maximum radiation dose that could be received by a member of the general public.

The population dose impact is based on the evaluation year site-specific data (i.e.,

food production, milk production, feed for milk animals and seafood production).

The doses were calculated using methods described in Regulatory Guide 1.109 and represent calculations for the 12-month reporting interval. Individual doses from batch and continuous releases were calculated using the annual average historic meteorological dispersion factors as described in the respective Offsite Dose Calculation Manual. Population doses were calculated using the meteorological dispersion coefficients for the twelve month reporting interval.

I l lI l it.

I iI Liquid Pathways Type Total Body Organ Age Group Adult Adult Location Site Boundary Site Boundary Pathwa i

Seafood Ingestion Seafood Ingestion l-l Salem Unit 1 Type Total Body Organ Dose (GILLI)

Salem Unit 2 Type Total Body Organ Dose (GILLI)

Hope Creek Total Body Organ Dose (Bone)

Dose 2.1OE-02 1.27E-01 Dose 1.64E-05 2.14E-02 Dose 2.40E-05 1.36E-04 mrem mrem Limit 3 mrem 10 mrem L

L mrem mrem Limit 3 mrem 10 mrem L

D mrem mrem Limit 3 mrem 10 mrem Site Population (Total)

Population (Average)

Dose 2.1OE-02 4.68E-06 person-rem mrem Limit N/A N/A L

L L

L 11

2005 SGS AND HCGS RADIOACTIVE EFFLUENTS RELEASE REPORT Air Pathways Type Total Body Skin Organ Age Group All All Infant Location Site Boundary Site Boundary 4.9 mi. W.

Pathway Direct Exposure Direct Exposure Milk, Ground Plane, Inhalation Salem Units 1&2 Type Total Body Skin Organ Dose (Thyroid)

Dose 1.21E-03 4.56E-04 1.48E-03 mrem mrem mrem Limit 500 mrem 3000 mrem 15 mrem Hope Creek TVpe Total Body Skin Organ Dose (Thyroid)

Dose 8.12E-04 1.53E-03 6.36E-02 mrem mrem mrem Limit 500 mrem 3000 mrem 15 mrem Site Population (Total)

Population (Average)

Dose 2.02E-03 4.49E-07 person-rem mrem Limit N/A N/A Direct Radiation Direct radiation may be estimated by thermoluminescent dosimetric (TLD) measurements. One method for comparing TLD measurements is by comparison with pre-operational data. It should be noted that the TLDs measure direct radiation from both the Salem and Hope Creek Generating Stations at Artificial Island, and natural background radiation.

TLD data for the twelve-month reporting period is given below:

TLD iS-l 5S-1 Location 0.55 miles N of Vent 1.0 mile E of Vent Measurement 4.50 mrad/std. month 3.45 mrad/std. month These values are interpreted to represent natural background, since the values are within the statistical variation associated with the pre-operational program results which are 3.7 mrad/standard month for TLD IS-1 and 4.2 mrad/standard month for TLD 5S-1.

12

2005 SGS AND HCGS RADIOACTIVE EFFLUENTS RELEASE REPORT Total Dose L

40CFR190 limits the total dose to members of the public due to radioactivity and radiation from uranium fuel cycle sources to:,

<25 mrem total body or any organ and;

<75 mrem thyroid for a calendar year.

For Artificial Island, the major sources of dose are from liquid and gaseous effluents from the Hope Creek and Salem plants.

The following doses to a "hypothetical maximum exposed individual" have been calculated for the twelve-month reporting period. They are the sum of gaseous and liquid pathway doses for the Salem 1 and 2 and Hope Creek plants:

9.92E-01 mrem Total Body 1.29E-01 mrem Organ (GI-LLI) 6.51E-02 mrem Thyroid L

Dose to members of the public due to activities inside the site boundary Dose to members of the public is limited to 100 mrem total effective dose equivalent (TEDE) in a year in accordance with 10CFR20.1301. The definition of members of the public changed on September 11, 2001. The various food vendors that have L

previously comprised the maximally exposed group are no longer allowed on site.

For this reporting period, the definition of the members of the public are the members of the New Jersey National Guard to augment the security force at the site.

Their typical patrol spans the site, and the following locations 16S1; CA8 and CAI5 (Hope Creek Barge Slip, Dredge Spoils and Baseball Field) are averaged to estimate their dose. In accordance with the requirements of ODCM 6.9.1.8 (SGS) and 6.9.1.7 U

(HCGS), the dose to members of the public inside the site boundary has been calculated based on the following assumptions:

L

a. The National Guard works a 40 hour4.62963e-4 days <br />0.0111 hours <br />6.613757e-5 weeks <br />1.522e-5 months <br /> week, therefore all doses are multiplied by 0.25 to assess their dose.

For the 12-month reporting period, January 1, 2005 to December 31, 2005 the calculated doses are:

2.43E-01 mrem TEDE Total Body 4.84E-04 mrem TEDE Organ (Lung) 1.63E-02 mrem TEDE Thyroid 13 U

2005 SGS AND HCGS RADIOACTIVE EFFLUENTS RELEASE REPORT Assessment

1.

Liquids:

Liquid effluents released from the Salem and Hope Creek Generating Stations resulted in a minimal dose to the hypothetical maximum exposed individual and were well within all applicable limits (Salem Unit 1 - 6.99E-01 % of Total Body Limit, Salem Unit 2 - 5.46E-04 % of Total Body Limit, and Hope Creek - 8.OOE-04 % of Total Body Limit).

When compared to releases in the previous reporting period, the Salem and Hope Creek Fission & Activation Products activity in the liquid effluents decreased. Liquid effluent releases continue to remain well within Federal limits and compare favorably to other nuclear utilities.

2.

Gaseous:

Gaseous effluents released from the Salem and Hope Creek Generating Stations resulted in a minimal dose to the hypothetical maximum exposed individual. The dose for the 12-month period was a small fraction of all applicable limits (Salem Unit 1 & 2 - 7.99E-03% of Total Body Limit and Hope Creek - 5.4 lE-03 % of Total Body Limit).

When compared to releases in the previous reporting period, the Salem and Hope Creek noble gas effluents activity decreased. Gaseous effluent releases for the Site continue to remain well within Federal limits and are comparable to other nuclear utilities. Fuel integrity and gaseous effluent processing equipment continue to be maintained in order to ensure that all releases of gaseous radioactivity are As-Low-As-Reasonably-Achievable (ALARA).

14

2005 SGS AND HCGS RADIOACTIVE EFFLUENTS RELEASE REPORT Ull Trends The following two trend graphs show the total curies of liquid and gaseous effluents released for Salem from 2000 through 2005. Calculated doses in the graphs are to the hypothetical maximum exposed individual.

Liquid Releases (SGS) Fission & Activation Products Curies Released and Calculated Doses l

li I

IL E

I-E 1.OOE+00 -

1.00E 1.OOE-02 4

1.OOE 1.OOE 1.OOE+00 I 1.OOE-01 1.00E-02 ~0a)0

+ Total Body

--E-Organ

-* Curies U.

I L

1.OOE-05.-

2000

-rC I --1.OOE-04 1.00E-05 2004 2005 L

2001 2002 2003 Year L

Gaseous Releases (SGS) Curies of Noble Gases Released and Calculated Doses L

E E

1.OOE+05 -_

1.OOE+04 -

1.00E+03 k_

1.OOE+02 -",

1.OOE+01 1.OOE+00 1.OOE-01 I Z 1.OOE-02---

1.OOE 1.OOE 2000 1.OOE+05 1.OOE+04 1.OOE+03 U) 1.OOE+02 C) 1.OOE+01 1.OOE+00 1.OOE-01 L

L 2001 2002 2003 2004

-4 1.OOE-02 2005 + Total Body Skin a- -Curies L,

Year I

L Li 15

2005 SGS AND HCGS RADIOACTIVE EFFLUENTS RELEASE REPORT The following two trend graphs show the total curies of liquid and gaseous effluents released for Hope Creek from 2000 through 2005. Calculated doses in the graphs are to the hypothetical maximum exposed individual.

Liquid Releases (HCGS) Fission & Activation Products Curies Released and Calculated Doses 1.OOE+00 -

1.00E-01 &a E 1.OOE-02 --

2 4 _

E 1.00E-03 *:

1.00E-04

  • 1.OOE 2000 1.OOE+00 1.OOE-01 1.OOE-02 M 1.OOE-03 =

1O

)

1.OOE-04 I

I I 1.00E-05 2001 2002 2003 2004 2005

-*- Total Body Organ a

Curies Year Gaseous Releases Curies of Noble Gases Released and Calculated Doses E

E!

E 1.OOE+03 -

1.OOE+02 A 1.OOE+01-1.OOE+00--=-

1.OOE 1.OOE-02 N 1.OOE-03 f;::

1.OOE-04 --

1.OOE-05 1.00E-06 1.00E-07 1 1.OOE-08 2000 1.OOE+02 1.OOE+01 1.00E+00 i 1.OOE-01 1.OOE-02 I.OOE-03 I1.OOE-04 1.00E-05 1.00E-06 1.OOE-07 1.OOE-08 2005 U)

C._

2001 2002 2003 2004 Year

-+Total Body aSkin Curies 16

2005 SGS AND HCGS RADIOACTIVE EFFLUENTS RELEASE REPORT PART F. METEOROLOGICAL DATA Cumulative joint wind frequency distributions by atmospheric stability class at the 33 feet elevation are provided for the reporting period at the end of this report in Appendix A.

PART G. OFFSITE DOSE CALCULATION MANUAL CHANGES L

Salem L

The Salem ODCM was revised twice during the reporting period. A copy of the Salem ODCM revision 19 is included in Appendix C.

U Salem ODCM Revision18 1

This revision became effective April 27, 2005, accomplishing the following:

1. Added (#) symbol to Item 2, Table 3.3-13 (pg 25)

L

2. Revised (**) footnote on Table 3.3-13 TABLE NOTATION (pg 26) - to read:

"** During containment purges or containment pressure - vacuum reliefs Applicability- -

R41A/D Monitors at all times, or R12A Monitors in all Modes (Mode 6 function is to alarm without automatic isolation)"

3. Added (#) footnote on Table 3.3-13 TABLE NOTATION (pg 26) - to read:

"# During Fuel Handling inside containment without containment closure (hatches open) only R41A/D can be credited for minimum channel operability L

During Fuel Handling inside containment with containment closure (hatches closed) RI2A may be credited for minimum channel operability"

4. Revised (**) footnote on Table 4.3-13 (pg 28) - to read:

C

"**During containment purge or containment pressure - vacuum relief Surveillance requirement -

R41A/D Monitors at all times L

R12A Monitors in all Modes (Mode 6 function is to alarm without automatic isolation)

During Fuel Handling inside containment without containment closure (hatches open) only R41A/D can be credited for minimum channel operability During Fuel Handling inside containment with containment closure (hatches closed) R12A may be credited for minimum channel operability"

5. Revised (*) footnote on Part II Calculational Methodologies Section 2.1 (pg 81) to read:

"The R12A in Mode 6 provides containment monitoring and alarm functions without automatic isolation"

6. Revised (**) footnote on Tables 2-2.1 and 2-2.2 (pgs 105 and 106) to read:

"**Automatic Isolation function is applicable in all MODES except MODE 6" 17 L

2005 SGS AND HCGS RADIOACTIVE EFFLUENTS RELEASE REPORT Justification: Technical Specification Amendments 263 and 245, "Relaxation of T.S.

Requirements Applicable During Movement of Irradiated Fuel," specify that fuel handling in containment can be performed with the equipment hatch open provided that: 1) containment closure can be performed within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />, 2) ventilation is taking suction from the containment, and 3) the release from a postulated fuel handling accident can be monitored.

This amendment removed the requirement to provide containment isolation of purge on a high rad signal when in Mode 6. ODCM Revision 17 implemented the T.S. Amendment by removing reference to R12A in Mode 6 and Defueled. This ODCM Revision provides redundancy to the R41A/D by allowing R12A to provide monitoring without automatic isolation during containment purges in Mode 6 and Defueled.

7. Revised ACTION 33 in Table 3.3-13 TABLE NOTATION (pg 26) - to remove wording:

"and the Surveillance Requirement 4.11.2.1.1 is performed" and add wording:

"Otherwise, suspend release of radioactive effluents via this pathway."

Justification: The ODCM is controlled Tech Specs Section 6.8.4.g - Radioactive Effluents Controls Program, IOCFR20 and NUREG-1301 ODCM Guidance: Standard Radiological Effluent Controls for PWRs. This revision is also consistent with the surveillance requirements of Hope Creek ODCM.

Salem ODCM Revision 19 This revision became effective September 7, 2005, accomplishing the following:

1. Removed the wording " Providing Alarm and Automatic Termination of Release" and added the # symbol - Items 2 & 3 Table 3.3-13 (pg 25)
2. Revised (**) footnote and added (#) footnote on Table 3.3-13 (pg 26) - modified wording:
    • During Containment Purges OR Containment Pressure - Vacuum Relief APPLICABILITY:

Modes 1-6, R41A/D Monitors providing Alarm and Automatic Termination of Release, or Modes 1-5, R12A Monitor providing Alarm and Automatic Termination of Release, or Mode 6, R12A Monitor providing Alarm only (Automatic Termination of Release is not required).

During Mode Undefined (Defueled) operation, containment purge is reclassified as a building ventilation process stream monitored by the PLANT VENT HEADER SYSTEM.

  1. During movement of irradiated fuel within containment with the Containment Equipment Hatch OPEN, only R4IA/D can be credited for MINIMUM CHANNEL OPERABLE.

18

2005 SGS AND HCGS RADIOACTIVE EFFLUENTS RELEASE REPORT L

During movement of irradiated fuel within containment with the Containment Equipment Hatch CLOSED, R41A/D or R12A may be credited for MINIMUM CHANNEL OPERABLE.

3. Removed the wording " Providing Alarm and Automatic Termination of Release" - Item 2 Table 4.3-13 (pg 27)
4. Revised (**) footnote on Table 4.3-13 (pg 28) - modified wording:
    • During Containment Purges OR Containment Pressure - Vacuum Relief Surveillance requirement -

L Modes 1-6, R41A/D Monitors providing Alarm and Automatic Termination of Release Modes 1-5, R12A Monitors providing Alarm and Automatic Termination of Release Mode 6, R12A Monitors providing Alarm only (Automatic Termination of L

Release is not required).

During Mode Undefined (Defueled) operation, containment purge is reclassified as a building ventilation process stream monitored by the PLANT VENT HEADER SYSTEM.

During movement of irradiated fuel within containment with the Containment Equipment X

Hatch OPEN, only R41A/D can be credited for MINIMUM CHANNEL OPERABLE.

During movement of irradiated fuel within containment with the Containment Equipment Hatch CLOSED, R41A/D or RI2A may be credited for MINIMUM CHANNEL L

OPERABLE.

Justification:

This ODCM further clarifies the 2 changes done by ODCM Revision 17 & 18 and further relaxes containment purging in refueling outages by redefining "purging" as "building U

ventilation" when the plant is in Mode Undefined (Defueled).

The design functions for the gaseous effluent radiation monitoring of releases from U

containment purge in Mode Undefined (Defueled) will be met by the use of the Plant Vent (PLANT VENT HEADER SYSTEM) radiation monitors. When defueled, "Purging" can be reclassified as a building ventilation stream feeding into the Plant Vent. This change to the ODCM relaxes the requirements of the RI2A - R41A/D monitors in a defueled containment, which was overly restrictive. This ODCM change allows the Plant Vent radiation monitors with grab sample backup to support purging when defueled.

19L

2005 SGS AND HCGS RADIOACTIVE EFFLUENTS RELEASE REPORT PART H. INOPERABLE MONITORS During this reporting period there were no effluent radiation monitors inoperable for greater than 30 days.

PART I. PROCESS CONTROL PROGRAM (PCP) CHANGES During the reporting period, there were no PCP changes.

PART J. ENVIRONMENTAL MONITORING LOCATION CHANGES Since there are no milk farms within 5 Km of the Site, in accordance with the Salem and Hope Creek Offsite Dose Calculation Manual (ODCM), broad leaf vegetation was planted, maintained and harvested. The broad leaf vegetation sample locations are (lSi, 15S1 and 16S1, onsite) and 10D1 located 3.9 miles SSW across the river.

The objectives and effectiveness of the Radioactive Environmental Monitoring Program (REMP) were maintained during this reporting period.

20

L 2005 SGS AND HCGS RADIOACTIVE EFFLUENTS RELEASE REPORT TABLE lA-1 SALEM GENERATING STATION - UNIT 1 EFFLUENTS AND WASTE DISPOSAL ANNUAL REPORT JANUARY - JUNE 2005 GASEOUS EFFLUENTS - SUMMATION OF ALL RELEASES L-I Lo I )Al U

Est.

Total Error l

Uw Units 1 s Quarter 2nd Quarter A.

Fission and Activation Gases

1.

Total Release Ci 2.40E

2.

Average Release Rate For Period Ci/sec 3.09E

3.

Percent of Technical Specification Limit 2.77E (ODCM 3.11.2.2(a))

B.

lodines

1.

Total Iodine-131 Ci 0.00E-

2.

Average Release Rate For Period Ci/sec 0.00E-

3.

Percent of Technical Specification Limit2 0.OOE-(ODCM 3.11.2.3(a))

C.

Particulates

1.

Particulates With Half-lives > 8 days Ci 2.35E

2.

Average Release Rate For Period Ci/sec 3.02E

3.

Percent of Technical Specification Limit2 2.17E (ODCM 3.11.2.3(a))

4.

Gross Alpha Ci 0.OOE-D.

Tritium

1.

Total Release Ci 1.66E.

2.

Average Release Rate For Period Ci/sec 2.14E

3.

Percent of Technical Specification Limit2 2.17E-(ODCM 3.11.2.3(a))

1. For batch releases, the estimated overall error is 10%.
2. lodines, Tritium, and Particulates are treated as a group.

The percent TS Limit is based on most limiting nuclide and Organ dose J

-01 1.71E-01 50%

L

-02 2.18E-02

-04 3.80E-04

,00 3.72E-07

,+00 4.73E-08

  • ,00 8.09E-04 f

50%

L U

L

-06 1.30E-06 50%

1.65E-07 D

-07 L

-05 8.09E-04

,-00 0.OOE+00 a

-01 l.1OE+01 50%

l

-02 1.40E+00

-05 8.09E-04 L

U LI 21 I

2005 SGS AND HCGS RADIOACTIVE EFFLUENTS RELEASE REPORT TABLE 1A-2 SALEM GENERATING STATION - UNIT 2 EFFLUENTS AND WASTE DISPOSAL ANNUAL REPORT JANUARY - JUNE 2005 GASEOUS EFFLUENTS - SUMMATION OF ALL RELEASES Est.

Total Units I" Quarter 2nd Quarter Error A.

Fission and Activation Gases

1.

Total Release Ci 1.97E+00 2.43E+00 50%

2.

Average Release Rate For Period Ci/sec 2.53E-01 3.09E-01

3.

Percent of Technical Specification Limit 1.45E-03 2.13E-03 (ODCM 3.11.2.2(a))

B.

lodines

1.

Total Iodine-131 Ci 0.OOE+00 3.38E-05 50%

2.

Average Release Rate For Period Ci/sec 0.OOE+00 4.30E-06

3.

Percent of Technical Specification Limit 0.OOE+00 6.1 IE-03 (ODCM 3.11.2.3(a))

C.

Particulates

1.

Particulates With Half-Ci 1.80E-06 8.71E-07 50%

lives > 8 days

2.

Average Release Rate Ci/sec 2.32E-07 1.1 1E-07 For Period

3.

Percent of Technical 7.1 1E-04 6.1 1E-03 Specification Limit2 (ODCM 3.11.2.3(a))

4.

Gross Alpha Ci 0.OOE+00 0.OOE+00 D.

Tritium i

1.

Total Release Ci 1.O1E+01 4.22E+01 50%

2.

Average Release Rate For Period Ci/sec 1.30E+00 5.37E+00

3.

Percent of Technical Specification Limit2 7.1 1E-04 6.1 1E-03 (ODCM 3.11.2.3(a))

1. For batch releases, the estimated overall error is 10%.
2. lodines, Tritium, and Particulates are treated as a group.

The percent TS Limit is based on most limiting nuclide and Organ dose 22

2005 SGS AND HCGS RADIOACTIVE EFFLUENTS RELEASE REPORT TABLE 1A-3 HOPE CREEK GENERATING STATION EFFLUENTS AND WASTE DISPOSAL ANNUAL REPORT JANUARY - JUNE 2005 GASEOUS EFFLUENTS - SUMMATION OF ALL RELEASES L

Est.

, I Total Error

, I Units 1st Quarter 2nd Quarter A.

Fission and Activation Gases

1.

Total Release Ci 1.79E

2.

Average Release Rate For Period Ci/sec 2.31E

3.

Percent of Technical Specification Limit 7.57E (ODCM 3.11.2.2(a))

B.

lodines

1.

Total Iodine-131 Ci 4.83E

2.

Average Release Rate For Period Ci/sec 6.21E

3.

Percent of Technical Specification Limit2 9.57E (ODCM 3.11.2.3(a))

C.

Particulates

1.

Particulates With Half-lives > 8 days Ci 4.59E

2.

Average Release Rate For Period Ci/sec 5.90E

3.

Percent of Technical Specification Limit2 9.57E (ODCM 3.11.2.3(a))

4.

Gross Alpha Ci 0.OOE D.

Tritium

1.

Total Release Ci 0.OOE-

2.

Average Release Rate For Period Ci/sec 0.OOE-

3.

Percent of Technical Specification Limit2 0.OOE-(ODCM 3.11.2.3(a))

1. For batch releases, the estimated overall error is 10%.
2. lodines, Tritium, and Particulates are treated as a group.

The percent TS Limit is based on most limiting nuclide and Organ dose U

_-03 4.99E-01 50%

L

,-04 6.36E-02

^-06 7.62E-04

,-04 1.03E-03 L

50%

,-05 1.3 lE-04

,-02 2.OOE-01 U

,-06 2.38E-05 50%

LI

,-07 3.03E-06

-02 2.OOE-01

+00 0.OOE+00

,+00 0.OOE+00 50%

4+00 0.OOE+00

,+00 0.OOE+00 L

L L

L l

23 Li

2005 SGS AND HCGS RADIOACTIVE EFFLUENTS RELEASE REPORT TABLE 1A-4 SALEM GENERATING STATION - UNIT 1 EFFLUENTS AND WASTE DISPOSAL ANNUAL REPORT JULY - DECEMBER 2005 GASEOUS EFFLUENTS - SUMMATION OF ALL RELEASES Est.

Total Error Units 3 rd Quarter 4 th Quarer A.

Fission and Activation Gases

1.

Total Release Ci 3.93E

2.

Average Release Rate For Period Ci/sec 4.95E

3.

Percent of Technical Specification Limit 3.68E (ODCM 3.11.2.2(a))

B.

lodines

1.

Total Iodine-131 Ci 6.19E

2.

Average Release Rate For Period Ci/sec 7.78E

3.

Percent of Technical Specification Limit2 3.17E (ODCM 3.11.2.3(a))

C.

Particulates

1.

Particulates With Half-lives > 8 days Ci 7.26E

2.

Average Release Rate For Period Ci/sec 9.13E

3.

Percent of Technical Specification Limit2 3.17E (ODCM 3.11.2.3(a))

4.

Gross Alpha Ci 0.OOE-D.

Tritium

1.

Total Release Ci 4.44E-

2.

Average Release Rate For Period Ci/sec 5.59E-

3.

Percent of Technical Specification Limit 3.17E (ODCM 3.11.2.3(a))

1. For batch releases, the estimated overall error is 10%.
2. lodines, Tritium, and Particulates are treated as a group.

The percent TS Limit is based on most limiting nuclide and Organ dose E-02 2.18E-01 E-03 2.74E-02

_-04 5.58E-04

_-07 1.54E-06

-08 1.94E-07

-03 4.28E-03

-06 2.90E-06

-07 3.65E-07

-03 4.28E-03

+00 0.0OE+00

+01 5.96E+01

+00 7.49E+00

-03 4.28E-03 50%

50%

50%

50%

24

2005 SGS AND HCGS RADIOACTIVE EFFLUENTS RELEASE REPORT TABLE lA-5 SALEM GENERATING STATION - UNIT 2 EFFLUENTS AND WASTE DISPOSAL ANNUAL REPORT JULY - DECEMBER 2005 GASEOUS EFFLUENTS - SUMMATION OF ALL RELEASES L

U Est.

Total Error L

Units 3r Quarter 4t Quarter A.

Fission and Activation Gases

1.

Total Release Ci 1.63E

2.

Average Release Rate For Period Ci/sec 2.05E

3.

Percent of Technical Specification Limit 3.OOE (ODCM 3.11.2.2(a))

B.

lodines

1.

Total Iodine-131 Ci 0.OOE-

2.

Average Release Rate For Period Ci/sec 0.00E-

3.

Percent of Technical Specification Limit2 0.OOE-(ODCM 3.11.2.3(a))

C.

Particulates

1.

Particulates With Half-lives > 8 days Ci 1.06E

2.

Average Release Rate For Period Ci/sec 1.33E

3.

Percent of Technical Specification Limit2 2.57E (ODCM 3.11.2.3(a))

4.

Gross Alpha Ci 0.OOE-D.

Tritium

1.

Total Release Ci 3.72E-

2.

Average Release Rate For Period Ci/sec 4.68E-

3.

Percent of Technical Specification Limit2 2.57E (ODCM 3.11.2.3(a))

1. For batch releases, the estimated overall error is 10%.
2. lodines, Tritium, and Particulates are treated as a group.

The percent TS Limit is based on most limiting nuclide and Organ dose L

-01 1.71E-01 50%

U

-02 2.14E-02

-04 5.64E-04

,+00 0.OOE+00 50%

,+00 0.OOE+00

,+00 0.OOE+00

-05 7.98E-07 50%

-06 1.OOE-07

-03 2.02E-03

,+00 0.OOE+00

,+01 2.92E+01 50%

L U

L L

L L

L

  • +00 3.67E+00

-03 2.02E-03 Li Li 25

2005 SGS AND HCGS RADIOACTIVE EFFLUENTS RELEASE REPORT TABLE 1A-6 HOPE CREEK GENERATING STATION EFFLUENTS AND WASTE DISPOSAL ANNUAL REPORT JULY - DECEMBER 2005 GASEOUS EFFLUENTS - SUMMATION OF ALL RELEASES Est.

Total Error Units 3 rd Quarter 4th Quarter A.

Fission and Activation Gases

1.

Total Release Ci 5.261

2.

Average Release Rate For Period Ci/sec 6.62E

3.

Percent of Technical Specification Limit 1.36E (ODCM 3.11.2.2(a))

B.

Iodines

1.

Total Iodine-131 Ci 1.37E

2.

Average Release Rate For Period Ci/sec 1.73E

3.

Percent of Technical Specification Limit2 2.73E (ODCM 3.11.2.3(a))

C.

Particulates

1.

Particulates With Half-lives>8days Ci 8.11E

2.

Average Release Rate For Period Ci/sec 1.02E

3.

Percent of Technical Specification Limit2 2.73E (ODCM 3.11.2.3(a))

4.

Gross Alpha Ci 0.OOE D.

Tritium

1.

Total Release Ci 0.OOE

2.

Average Release Rate For Period Ci/sec 0.00E-

3.

Percent of Technical Specification Limit2 0.00E-(ODCM 3.11.2.3(a))

1. For batch releases, the estimated overall error is 10%.
2. Iodines, Tritium, and Particulates are treated as a group.

The percent TS Limit is based on most limiting nuclide and Organ dose E-01 4.65E+00 E-02 5.86E-01 50%

E-03 E-03 E-04 E-01

-05 1.61E-02 1.38E-03 1.73E-04 2.79E-01 1.02E-05 1.29E-06 2.79E-01 50%

50%

-05

-01

+00 0.00E+00

+00 1.01E+02 50%

+00 1.28E+01

+00 2.79E-01 26

U 2005 SGS AND HCGS RADIOACTIVE EFFLUENTS RELEASE REPORT TABLE 1B SALEM AND HOPE CREEK GENERATING STATION EFFLUENTS AND WASTE DISPOSAL ANNUAL REPORT L

JANUARY - DECEMBER 2005 GASEOUS EFFLUENTS - ELEVATED RELEASES L

Salem and Hope Creek Generating Stations have no elevated release points.

L L

L L

L L

l 27 L

L~

2005 SGS AND HCGS RADIOACTIVE EFFLUENTS RELEASE REPORT TABLE iC-1 SALEM GENERATING STATION - UNIT 1 EFFLUENTS AND WASTE DISPOSAL ANNUAL REPORT JANUARY - JUNE 2005 GASEOUS EFFLUENTS - GROUND LEVEL RELEASES Continuous Mode Batch Mode Nuclides Released Units I't Quarter 2nd Quarter 1st Ouarter 2nd uarter

1.

Fission Gases Xenon-135 Ci 0.OOE+00 0.OOE+00 3.46E-04 O.OOE+00 Krypton-85 Ci 0.OOE+00 0.OOE+00 0.OOE+00 6.15E-03 Argon-41 Ci 0.OOE+00 0.OOE+00 1.27E-02 2.39E-02 Xenon-133 Ci 0.OOE+00 0.OOE+00 2.27E-01 1.41E-01 Totals Ci O.OOE+00 O.OOE+00 2.40E-01 1.71E-01

2.

Iodine Iodine-131 Ci 0.OOE+00 3.72E-07 0.OOE+00 0.OOE+00 Iodine-133 Ci 0.OOE+00 1.12E-05 0.OOE+00 0.OOE+00 Totals Ci O.OOE+00 1.16E-05 O.OOE+00 O.OOE+00

3.

Particulates (Half-life >8 days)

Cobalt-60 Ci 1.03E-06 0.OOE+00 0.OOE+00 0.OOE+00 Cesium-137 Ci 1.32E-06 1.30E-06 0.OOE+00 0.OOE+00 Totals Ci 2.35E-06 1.30E-06 O.OOE+00 0.OOE+00

4.

Tritium Ci O.OOE+00 1.OOE+01 l

1.66E-01 9.90E-01 28

2005 SGS AND HCGS RADIOACTIVE EFFLUENTS RELEASE REPORT TABLE 1C-2 U

SALEM GENERATING STATION - UNIT 2 EFFLUENTS AND WASTE DISPOSAL ANNUAL REPORT JANUARY - JUNE 2005 1 GASEOUS EFFLUENTS - GROUND LEVEL RELEASES Continuous Mode Batch Mode U

Nuclides Released Units 1st Ouarter 2nd Quarter 1St Quarter 2nd Quarter

1.

Fission Gases Krypton-88 Ci O.OOE+00 0.00E+00 0.00E+00 1.14E-03 L

Krypton-85m Ci 0.OOE+00 O.OOE+00 O.OOE+00 2.93E-03 Xenon-133m Ci 0.OOE+00 0.OOE+00 0.OOE+00 2.74E-02 Argon-41 Ci O.OOE+00 0.00E+00 8.73E-1 1 3.39E-02 L

Xenon-135 Ci 0.OOE+00 0.OOE+00 1.07E-02 2.23E-01 Xenon-133 Ci 0.00E+00 O.OOE+00 1.96E+00 2.14E+00 1

Totals Ci O.OOE+00 O.OOE+00 1.97E+00 2.43E+00

2.

Iodine Iodine-133 Ci 0.00E+00 2.43E-05 0.00E+00 0.OOE+00 Iodine-131 Ci 0.OOE+00 3.38E-05 0.OOE+00 0.00E+00 Iodine-132 Ci 0.OOE+00 4.15E-05 0.OOE+00 0.OOE+00 L

Totals Ci O.OOE+00 9.97E-05 O.OOE+00 O.OOE+00

3.

Particulates L

(Half-life >8 days)

[

Cesium-137 Ci 1.80E-06 0.OOE+00 0.OOE+00 0.OOE+00 Cobalt-58 Ci 0.OOE+00 8.71E-07 0.OOE+00 0.00E+00 Totals Ci 1.80E-06 8.71E-07 O.OOE+00 O.OOE+00 0

4.

Tritium Ci 1.OOE+01 4.21E+01 I

1.07E-01 1.40E-01 0

U L

29 L

L

2005 SGS AND HCGS RADIOACTIVE EFFLUENTS RELEASE REPORT TABLE 1C-3 HOPE CREEK GENERATING STATION EFFLUENTS AND WASTE DISPOSAL ANNUAL REPORT JANUARY - JUNE 2005 GASEOUS EFFLUENTS - GROUND LEVEL RELEASES Continuous Mode Units I't Ouarter 2nd Ouarter Batch Mode 1 st Ouarter 2nd Ouarter Nuclides Released

1.

Fission Gases Argon-41 Xenon-133 Xenon-133m Xenon-135 Xenon-135m Totals Ci Ci Ci Ci Ci Ci 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 9.OOE+00 0.OOE+00 2.44E-01 0.OOE+00 2.44E-01 0.OOE+00 4.89E-01 4.02E-04 5.26E-04 0.OOE+00 8.65E-04 0.OOE+00 1.79E-03 0.OOE+00 9.58E-03 2.93E-04 8.68E-04 4.33E-04 1.12E-02

2.

Iodine Iodine-131 Iodine-133 Totals

3.

Particulates (Half-life >8 days)

Manganese-54 Cobalt-60 Totals Ci Ci Ci Ci Ci Ci 4.83E-04 2.61E-02 2.66E-02 0.OOE+00 4.59E-06 4.59E-06 1.03E-03 5.26E-02 5.36E-02 2.38E-05 0.OOE+00 2.38E-05 0.OOE+00 0.OOE+00 O.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00

4.

Tritium Ci O.OOE+00 O.OOE+00 I

O.OOE+00 O.OOE+00 30

L 2005 SGS AND HCGS RADIOACTIVE EFFLUENTS RELEASE REPORT TABLE 1C-4 SALEM GENERATING STATION - UNIT 1 EFFLUENTS AND WASTE DISPOSAL ANNUAL REPORT f

JULY - DECEMBER 2005 L

GASEOUS EFFLUENTS - GROUND LEVEL RELEASES Continuous Mode Batch Mode L

Nuclides Released Units 3rd Quarter 4th Ouarter 3 rd Quarter 4th Quarter

1.

Fission Gases Krypton-85m Ci 0.OOE+00 0.OOE+00 0.OOE+00 2.34E-04 U

Xenon-133m Ci 0.00E+00 0.00E+00 0.00E+00 3.06E-03 Xenon-135 Ci 0.OOE+00 0.OOE+00 0.OOE+00 1.43E-02 Argon-41 Ci 0.OOE+00 O.OOE+00 2.79E-02 3.36E-02 L

Xenon-133 Ci 0.OOE+00 0.OOE+00 1.14E-02 1.67E-01 Totals Ci O.OOE+00 O.OOE+00 3.93E-02 2.18E-01

2.

Iodine Iodine-131 Ci 6.19E-07 1.54E-06 0.OOE+00 0.OOE+00 Iodine-133 Ci 4.45E-05 2.57E-05 0.OOE+00 0.OOE+00 L

Iodine-132 Ci 0.00E+00 0.OOE+00 0.OOE+00 1.97E-05 Totals Ci 4.51E-05 2.73E-05 O.OOE+00 1.97E-05 L

3.

Particulates (Half-life >8 L

days)

Niobium-95 Ci 1.44E-06 0.OOE+00 0.OOE+00 0.OOE+00 Cobalt-58 Ci 5.82E-06 2.25E-06 0.OOE+00 6.45E-07 L

Totals Ci 7.26E-06 2.25E-06 O.OOE+00 6.45E-07

4.

Tritium Ci 4.37E+01 5.89E+01 I

6.89E-01 6.64E-01 D

L L

31 L

L

2005 SGS AND HCGS RADIOACTIVE EFFLUENTS RELEASE REPORT TABLE 1C-5 SALEM GENERATING STATION - UNIT 2 EFFLUENTS AND WASTE DISPOSAL ANNUAL REPORT JULY - DECEMBER 2005 GASEOUS EFFLUENTS - GROUND LEVEL RELEASES Continuous Mode Units 3r' Ouarter 4h Ouarter Batch Mode 3rd Ouarter 4 Quarter Nuclides Released

1.

Fission Gases Xenon-135 Argon-41 Xenon-133 Totals Ci Ci Ci Ci 0.00E+00 0.OOE+00 0.OOE+00 O.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 0.00E+00 1.76E-02 1.45E-01 1.63E-01 2.41E-03 3.81E-02 1.30E-01 1.71E-01

2.

Iodine Totals O.OOE+00 I

Ci O.OOE+00 O.OOE+00 O.OOE+00

3.

Particulates (Half-life >8 days)

Cobalt-58 Totals 7.98E-07 7.98E-07 Ci Ci 1.06E-05 1.06E-05 0.OOE+00 O.OOE+00 0.OOE+00 O.OOE+00

4.

Tritium Ci 3.69E+01 2.89E+01 I

2.64E-01 2.46E-01 32

U 2005 SGS AND HCGS RADIOACTIVE EFFLUENTS RELEASE REPORT TABLE 1C-6 HOPE CREEK GENERATING STATION EFFLUENTS AND WASTE DISPOSAL ANNUAL REPORT JULY - DECEMBER 2005 L

GASEOUS EFFLUENTS - GROUND LEVEL RELEASES Continuous Mode Batch Mode Nuclides Released Units 3rd Quarter 4th Quarter 3rd Quarter 4t Quarter

1.

Fission Gases Xenon-133 Ci 0.OOE+00 1.66E-05 4.07E-03 0.OOE+00 A

Xenon-135m Ci 0.OOE+00 2.06E+00 0.OOE+00 0.00E+00 Xenon-135 Ci 5.22E-01 2.59E+00 2.93E-04 0.OOE+00 Totals Ci 5.22E-01 4.65E+00 4.37E-03 O.OOE+00

2.

Iodine Iodine-131 Ci 1.37E-03 1.38E-03 0.OOE+00 0.OOE+00 Iodine-132 Ci 0.OOE+00 8.05E-03 0.OOE+00 0.OOE+00 Iodine-133 Ci 7.45E-02 7.20E-02 0.OOE+00 0.OOE+00 Totals Ci 7.59E-02 8.14E-02 0.00E+00 O.OOE+00 L

3.

Particulates L

(Half-life >8 days)

Cobalt-60 Ci 7.24E-05 1.76E-06 0.OOE+00 0.00E+00 L

Barium-140 Ci 8.63E-06 8.45E-06 0.OOE+00 0.OOE+00 Totals Ci 8.10E-05 1.02E-05 O.OOE+00 O.OE+00

4.

Tritium Ci O.OOE+00 1.01E+02 O.OOE+00 O.OOE+00 L

L 33 L

L

2005 SGS AND HCGS RADIOACTIVE EFFLUENTS RELEASE REPORT TABLE 2A-1 SALEM GENERATING STATION - UNIT 1 EFFLUENTS AND WASTE DISPOSAL ANNUAL REPORT JANUARY - JUNE 2005 LIQUID EFFLUENTS - SUMMATION OF ALL RELEASES Est.

Total Error Units 1st Quarter 2nd Quarter A.

Fission and Activation Products

1.

Total Release

2.

Average Diluted Concentration

3.

Percent of Technical Specification Limit (ODCM 3.11.1.2(a))

B.

Tritium

1.

Total Release

2.

Average Diluted Concentration

3.

Percent of Technical Specification Limit (ODCM 3.11.1.1)

C.

Dissolved and Entrained Noble Gases

1.

Total Release

2.

Average Diluted Concentration

3.

Percent of Technical Specification Limit (ODCM 3.11.1.1)

D.

Gross Alpha Total Release E.

Volume of Waste Release (Prior to Dilution)

F.

Volume of Dilution Water Used During Entire Period Ci 1.1 E-03 Ci/ml 2.55E-12 9.94E-05 Ci 8.18E+01 Ci/ml 1.88E-07 6.26E-03 Ci 6.5 1E-04 3.04E-03 25%

6.84E-12 7.66E-04 1.85E+02 25%

4.18E-07 1.39E-02 2.37E-03 25%

5.33E-12 2.67E-06 0.00E+00 25%

5.42E+07 25%

4.44E+11 25%

Ci/ml 1.49E-12 7.47E-07 Ci 0.00E+00 Liters 5.32E+07 Liters 4.36E+l 1 34

2005 SGS AND HCGS RADIOACTIVE EFFLUENTS RELEASE REPORT TABLE 2A-2 SALEM GENERATING STATION - UNIT 2 EFFLUENTS AND WASTE DISPOSAL ANNUAL REPORT JANUARY - JUNE 2005 LIQUID EFFLUENTS - SUMMATION OF ALL RELEASES 1L i

Ii Est.

Total Error L

Units ISt Quarter 2nd Quarter A.

Fission and Activation Products I.

Total Release

2.

Average Diluted Concentration

3.

Percent of Technical Specification Limit (ODCM 3.11.1.2(a))

B.

Tritium

1.

Total Release

2.

Average Diluted Concentration

3.

Percent of Technical Specification Limit (ODCM 3.11.1.1)

C.

Dissolved and Entrained Noble Gases

1. Total Release
2.

Average Diluted Concentration

3.

Percent of Technical Specification Limit (ODCM 3.11.1.1)

D.

Gross Alpha Total Release E.

Volume of Waste Release (Prior to Dilution)

F.

Volume of Dilution Water Used During Entire Period L

Ci 1.90E-04 6.30E-04 25%

Ci/ml 4.42E-13 2.09E-12 8.47E-05 7.15E-04 Ci 5.26E+01 8.14E+01 25%

Ci/ml 1.23E-07 2.71E-07 4.08E-03 9.02E-03 Ci 2.86E-04 3.54E-03 25%

Ci/ml 6.67E-13 1.18E-11 3.33E-07 5.88E-06 Ci 0.00E+00 0.OOE+00 25%

Liters 4.95E+07 3.58E+07 25%

Liters 4.29E+l 1 3.01E+1 1 25%

L U

L L

U E

L U

L U

L L

35 L

2005 SGS AND HCGS RADIOACTIVE EFFLUENTS RELEASE REPORT TABLE 2A-3 HOPE CREEK GENERATING STATION EFFLUENTS AND WASTE DISPOSAL ANNUAL REPORT JANUARY - JUNE 2005 LIQUID EFFLUENTS - SUMMATION OF ALL RELEASES Est.

Total Error Units 1st Quarter 2nd Quarter A.

Fission and Activation Products

1.

Total Release

2.

Average Diluted Concentration

3.

Percent of Technical Specification Limit (ODCM 3.11.1.2(a))

B.

Tritium

1.

Total Release

2.

Average Diluted Concentration

3.

Percent of Technical Specification Limit (ODCM 3.11.1.1)

C.

Dissolved and Entrained Noble Gases

1.

Total Release

2.

Average Diluted Concentration

3.

Percent of Technical Specification Limit (ODCM 3.11.1.1)

D.

Gross Alpha Total Release E.

Volume of Waste Release (Prior to Dilution)

F.

Volume of Dilution Water Used During Entire Period Ci 8.53E-04 Ci/mi 5.70E-1 l 4.85E-05 Ci 5.01E+00 Ci/ml 3.35E-07 1.12E-02 Ci 5.22E-04 Ci/ml 3.49E-1 1 1.74E-05 Ci 0.OOE+00 Liters 5.18E+07 Liters 1.50E+10 4.25E-04 25%

2.77E-1 1 7.75E-06 3.57E+00 25%

2.33E-07 7.76E-03 2.52E-04 25%

1.64E-11 8.22E-06 0.00E+00 25%

5.16E+07 25%

1.53E+10 25%

36

L 2005 SGS AND HCGS RADIOACTIVE EFFLUENTS RELEASE REPORT TABLE 2A-4 SALEM GENERATING STATION - UNIT 1 EFFLUENTS AND WASTE DISPOSAL ANNUAL REPORT JULY - DECEMBER 2005 LIQUID EFFLUENTS - SUMMATION OF ALL RELEASES L

Est.

L Total Error f I Units 3rd Quarter 4th Quarter A.

Fission and Activation Products I.

Total Release

2.

Average Diluted Concentration

3.

Percent of Technical Specification Limit (ODCM 3.11.1.2(a))

B.

Tritium

1.

Total Release

2.

Average Diluted Concentration

3.

Percent of Technical Specification Limit (ODCM 3.11.1.1)

C.

Dissolved and Entrained Noble Gases

1.

Total Release

2.

Average Diluted Concentration

3.

Percent of Technical Specification Limit (ODCM 3.11.1.1)

D.

Gross Alpha Total Release E.

Volume of Waste Release (Prior to Dilution)

F.

Volume of Dilution Water Used During Entire Period U

Ci 1.22E-03 6.48E-03 25%

C Ci/ml 2.61E-12 1.96E-l l 1.74E-04 2.55E+00 Ci 6.49E+01 4.78E+00 25%

Ci/ml 1.39E-07 1.45E-08 4.62E-03 4.83E-04 L

L L

L Ci 4.99E-05 7.32E-05 25%

d Ci/ml 1.07E-13 2.22E-13 5.33E-08 l.1 E-07 Ci 0.OOE+00 0.00E+00 25%

Liters 5.41E+07 6.21E+07 25%

f L

L Liters 4.68E+11 3.30E+l1 25%

L L

37 L

2005 SGS AND HCGS RADIOACTIVE EFFLUENTS RELEASE REPORT TABLE 2A-5 SALEM GENERATING STATION - UNIT 2 EFFLUENTS AND WASTE DISPOSAL ANNUAL REPORT JULY - DECEMBER 2005 LIQUID EFFLUENTS - SUMMATION OF ALL RELEASES Est.

Total Error Units 3rd Quarter 4th Quarter A.

Fission and Activation Products

1.

Total Release

2.

Average Diluted Concentration

3.

Percent of Technical Specification Limit (ODCM 3.11.1.2(a))

B.

Tritium

1.

Total Release

2.

Average Diluted Concentration

3.

Percent of Technical Specification Limit (ODCM 3.11.1.1)

C.

Dissolved and Entrained Noble Gases

1. Total Release
2.

Average Diluted Concentration

3.

Percent of Technical Specification Limit (ODCM 3.11.1.1)

D.

Gross Alpha Total Release E.

Volume of Waste Release (Prior to Dilution)

F.

Volume of Dilution Water Used During Entire Period Ci 2.71E-04 1.42E-03 25%

Ci/ml 5.89E-13 3.18E-12 1.61E-04 1.3 1E-04 Ci 6.43E+01 1.23E+00 25%

Ci/ml 1.40E-07 2.76E-09 4.66E-03 9.20E-05 Ci 1.64E-05 5.09E-05 25%

Ci/ml 3.57E-14 1.14E-13 1.78E-08 5.70E-08 Ci 0.00E+00 0.OOE+00 25%

Liters 5.06E+07 5.06E+07 Liters 4.60E+11 4.46E+11 25%

25%

38

L 2005 SGS AND HCGS RADIOACTIVE EFFLUENTS RELEASE REPORT TABLE 2A-6 HOPE CREEK GENERATING STATION EFFLUENTS AND WASTE DISPOSAL ANNUAL REPORT JULY - DECEMBER 2005 LIQUID EFFLUENTS - SUMMATION OF ALL RELEASES L

Est.

Total Error L

Units 3rd Quarter 4t Quarter A.

Fission and Activation Products

1.

Total Release

2.

Average Diluted Concentration

3.

Percent of Technical Specification Limit (ODCM 3.11.1.2(a))

B.

Tritium

1. Total Release
2.

Average Diluted Concentration

3.

Percent of Technical Specification Limit (ODCM 3.11.1.1)

C.

Dissolved and Entrained Noble Gases

1.

Total Release

2.

Average Diluted Concentration

3.

Percent of Technical Specification Limit (ODCM 3.11.1.1)

D.

Gross Alpha Total Release E.

Volume of Waste Release (Prior to Dilution)

F.

Volume of Dilution Water Used During Entire Period I

Ci 2.98E-02 6.87E-06 25%

L Ci/ml 1.46E-09 4.47E-13 L

2.72E-03 9.09E-05 Ci 3.43E+00 7.57E-01 U

25%

Ci/ml 1.68E-07 4.93E-08 5.60E-03 1.64E-03 L

L Ci 5.91E-04 2.24E-05 25%

L Ci/ml 2.89E-11 1.46E-12 1.45E-05 7.29E-07 Ci 0.OOE+00 0.OOE+00 25%

Liters 5.30E+07 5.02E+07 25%

Liters 2.04E+10 1.54E+10 25%

1 L

L L

L 39 L

2005 SGS AND HCGS RADIOACTIVE EFFLUENTS RELEASE REPORT TABLE 2B-1 SALEM GENERATING STATION - UNIT 1 EFFLUENTS AND WASTE DISPOSAL ANNUAL REPORT JANUARY - JUNE 2005 LIQUID EFFLUENTS Nuclides Released Continuous Mode Units l Quarter 2nd Quarte Batch Mode 1st Ouarter 2nd Quarter Fission and Activation Products Silver-110m Cobalt-57 Cobalt-58 Cobalt-60 Cesium-134 Cesium-137 Manganese-54 Niobium-95 Niobium-97 Ruthinium-105 Antimony-125 Antimony-126 Tin-117m Tellurium-132 Zinc-95 Totals Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci 0.OOE+00 0.00E+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.00E+00 0.OOE+00 0.00E+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 2.92E-05 0.OOE+00 5.25E-05 6.90E-04 2.12E-05 2.74E-04 1.46E-05 0.OOE+00 8.61E-06 0.OOE+00 2.13E-05 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 1.11E-03 0.OOE+00 5.34E-06 9.49E-04 1.20E-03 8.35E-05 5.29E-04 1.78E-05 7.90E-05 0.OOE+00 3.17E-05 6.57E-05 7.83E-06 4.88E-05 5.67E-06 1.90E-05 3.04E-03

2.

Tritium Ci 4.07E-01 4.63E-01 8.14E+01 1.85E+02

3.

Dissolved and Entrained Noble Gases Xenon-133 Totals Ci Ci 0.OOE+00 O.OOE+00 0.OOE+00 O.OOE+00 6.5 iE-04 6.51E-04 2.37E-03 2.37E-03 40

2005 SGS AND HCGS RADIOACTIVE EFFLUENTS RELEASE REPORT TABLE 2B-2 SALEM GENERATING STATION - UNIT 2 EFFLUENTS AND WASTE DISPOSAL ANNUAL REPORT JANUARY - JUNE 2005 LIQUID EFFLUENTS U

L Continuous Mode Units 1st Quarter 2Ind Ouarte Batch Mode 15t Ouarter 2nd Quarter LI Nuclides Released I 1 L"

1.

Fission and Activation Products LI Silver 1I Om Cobalt-58 Cobalt-60 Cesium-137 Niobium-97 Tin-i 17m Totals Ci Ci Ci Ci Ci Ci Ci 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 0.OOE+00 0.00E+00 0.OOE+00 0.00E+00 0.OOE+00 0.OOE+00 O.OOE+00 1.54E-05 4.5 1E-05 1.13E-04 0.OOE+00 1.58E-05 O.OOE+00 1.90E-04 0.OOE+00 4.08E-04 1.43E-04 7.13E-05 0.OOE+00 7.55E-06 6.30E-04

2.

Tritium Ci 8.68E-02 1.97E-01 5.25E+01 8.12E+01 C

3.

Dissolved and Entrained Noble Gases Xenon-133 Xenon-135 Totals a

Ci Ci Ci 0.OOE+00 0.OOE+00 O.OOE+00 0.OOE+00 0.OOE+00 9.OOE+00 2.86E-04 0.OOE+00 2.86E-04 3.37E-03 1.70E-04 3.54E-03 C

n U

L L

I 41 L

2005 SGS AND HCGS RADIOACTIVE EFFLUENTS RELEASE REPORT TABLE 2B-3 HOPE CREEK GENERATING STATION EFFLUENTS AND WASTE DISPOSAL ANNUAL REPORT JANUARY - JUNE 2005 LIQUID EFFLUENTS Continuous Mode Units I't Ouarter 2 d Quarter Batch Mode Ist Quarter 2nd Quater Nuclides Released

1.

Fission and Activation Products Cobalt-58 Cobalt-60 Chromium-51 Cesium-137 Iodine-131 Manganese-54 Strontium-89 Totals Ci Ci

'Ci Ci Ci Ci Ci Ci 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 0.OOE+00 0.OOE+00 0.OOE+O0 0.OOE+O0 0.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 1.OOE-04 5.03E-04 0.OOE+00 8.73E-08 0.OOE+00 2.50E-04 0.OOE3+00 8.53E-04 3.13E-05 6.39E-05 8.94E-05 0.00E+00 1.02E-06 1.07E-04 1.32E-04 4.25E-04

2.

Tritium Ci 3.40E-02 O.OOE+00

3.

Dissolved and Entrained Noble Gases Xenon-133 Xenon-135 Totals 4.98E+oo 3.09E-04 2.13E-04 5.22E-04 3.57E+00 2.1 OE-04 4.14E-05 2.51E-04 Ci Ci Ci 0.OOE+00 0.OOE+00 O.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 42

U 2005 SGS AND HCGS RADIOACTIVE EFFLUENTS RELEASE REPORT TABLE 2B-4 SALEM GENERATING STATION - UNIT 1 EFFENTS AND WASTE DISPOSAL ANNUAL REPORT JULY - DECEMBER 2005 LIQUID EFFLUENTS L

U Continuous Mode Units 3rd Quarter 4h Quarter Batch Mode 3rd Quarter 4t" Quarter i11 Nuclides Released

1.

Fission and Activation Products Cobalt-58 Cobalt-60 Cesium-134 Cesium-137 Niobium-97 Antimony-125 Totals

  • 1I Ci Ci Ci Ci Ci Ci Ci 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 0.OOE+00 0.00E+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 3.03E-04 5.56E-04 3.75E-05 2.43E-04 8.25E-06 7.68E-05 1.22E-03 3.55E-03 1.62E-03 1.1 6E-04 8.77E-04 O.OOE+00 3.12E-04 6.48E-03 I

L

2.

Tritium

3.

Dissolved and Entrained Noble Gases Xenon-133 Xenon-135 Totals Ci 3.94E-01 6.52E-01 6.45E+01 4.99E-05 0.OOE+00 4.99E-05 4.13E+00 L

Ci Ci Ci 0.00E+/-00 0.OOE+00 O.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 6.32E-05 9.94E-06 7.32E-05 U

Lj L

C 43 L

2005 SGS AND HCGS RADIOACTIVE EFFLUENTS RELEASE REPORT TABLE 2B-5 SALEM GENERATING STATION - UNIT 2 EFFLUENTS AND WASTE DISPOSAL ANNUAL REPORT JULY - DECEMBER 2005 LIQUID EFFLUENTS Continuous Mode Units 3rd Ouarter 4h Quarter Batch Mode 3rd ouarter 4th Ouarter Nuclides Released

1.

Fission and Activation Products Cobalt-58 Cobalt-60 Cesium-134 Cesium-137 Antimony-125 Tin-117m Totals Ci Ci Ci Ci Ci Ci Ci 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 7.82E-05 8.60E-05 1.83E-05 8.83E-05 0.OOE+00 0.OOE+00 2.71E-04 1.02E-03 1.66E-04 2.76E-06 1.83E-05 2.09E-04 5.84E-06 1.42E-03 2..

Tritium

3.

Dissolved and Entrained Noble Gases Xenon-133 Xenon-135 Totals Ci 7.92E-01 1.23E+00 6.35E+01 O.OOE+00 Ci Ci Ci 0.OOE+00 0.OOE+00 O.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 1.64E-05 0.OOE+00 1.64E-05 3.85E-05 1.24E-05 5.09E-05 44

2005 SGS AND HCGS RADIOACTIVE EFFLUENTS RELEASE REPORT TABLE 2B-6 HOPE CREEK GENERATING STATION EFFLUENTS AND WASTE DISPOSAL ANNUAL REPORT JULY - DECEMBER 2005 LIQUID EFFLUENTS L

Continuous Mode Units 3rd Ouarter 4h Quarter Batch Mode 3'd Quarter 4th Ouarter U

Nuclides Released

1.

Fission and Activation Products Cobalt-58 Cobalt-60 Cesium-137 Iron-55 Iodine-131 Iodine-132 Iodine-133 Iodine-134 Iodine-135 Manganese-54 Sodium-24 Strontium-89 Yttrium-91m Zinc-65 Totals L

Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 4.45E-06 1.92E-05 1.43E-07 2.79E-02 3.80E-05 1.78E-05 1.20E-04 9.1 5E-06 7.93E-05 2.05E-05 6.83E-07 1.57E-03 1.27E-06 0.OOE+00 2.98E-02 1.1 5E-07 4.74E-06 2.55E-07 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 1.49E-06 0.OOE+00 0.OOE+00 0.OOE+00 2.67E-07 6.87E-06 L

I )

L C

2.

Tritium

3.

Dissolved and Entrained Noble Gases Xenon-133 Xenon-135 Xenon-135m Totals Ci 1.29E-01 6.53E-01 I 3.30E+00 1.04E-01 C

Ci Ci Ci Ci 0.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 0.OOE3+00 0.OOE3+00 0.OOE+00 O.OOE+00 1.49E-04 4.199E-04 2.33E-05 5.91 E-04 5.75E-06 1.66E-05 0.OOE+00 2.24E-05 L

L L

L 45

2005 SGS AND HCGS RADIOACTIVE EFFLUENTS RELEASE REPORT TABLE 3A-1 SALEM GENERATING STATION - UNITS 1 AND 2 EFFLUENTS AND WASTE DISPOSAL ANNUAL REPORT JANUARY - JUNE 2005 SOLID WASTE AND IRRADIATED FUEL SHIPMENTS SOLID RADWASTE SHIPPED OFFSITE FOR BURLAL OR DISPOSAL (Not Iradiated Fuel)

SGS 1 A. Type of Waste (Class A)

Units, 6-Month Period Est. Total Error
a.

Resins, Filters, Sludges, m) 0.OOE+00 25%

Evaporator Bottoms Ci O.OOE+00

b. Dry Compressible Waste, m3 3.26E+02 25%

Contaminated Equipment Ci 1.13E+00

c. Irradiated Components, m 3 0.OOE+00 25%

Control Rods Ci 0.OOE+00

d. Others - Unit 2 Reactor Head m3 2.50E+02 25%

Equipment Ci l.91E-02 1 Volumes are measured, activities are estimated 2A. Estimate of Major Nuclide Composition (>1%) - SGS DAW U2 Rx Head Equip I

Ci Nuclides Tritium Manganese-54 Iron-55 Cobalt-58 Cobalt-60 Nickel-63 Niobium-95 Cesium-134 Cesuim-137 Cerium-144 Ci 3.49 1.18 35.68 27.10 4.45 12.95 1.18 5.22 8.25 0.00 3.96E-02 1.34E-02 4.05E-01 3.07E-01 5.04E-02 1.47E-01 1.33E-02 5.92E-02 9.35E-02 0.00E+00 8.94 0.00 6.00 0.00 11.37 49.78 0.00 0.00 21.13 2.20 1.71E-03 0.OOE+00 1.15E-03 0.OOE+00 2.18E-03 9.55E-03 0.OOE+00 0.OOE+00 4.05E-03 4.22E-04 46

L 2005 SGS AND HCGS RADIOACTIVE EFFLUENTS RELEASE REPORT TABLE 3A-1 (Continued)

SALEM GENERATING STATION - UNITS 1 AND 2 EFFLUENTS AND WASTE DISPOSAL ANNUAL REPORT

-JANUARY - JUNE 2005 SOLID WASTE AND IRRADIATED FUEL SHIPMENTS SOLID RADWASTE SHIPPED OFFSITE FOR BURIAL OR DISPOSAL L

L Li 3A. Solid Waste Disposal (Class A or less) - SGS Number of Mode of Shipments Transportation Destination Type of Containers Metal L

10 Truck Memphis, TN L

U 47 L

2005 SGS AND HCGS RADIOACTIVE EFFLUENTS RELEASE REPORT TABLE 3A-2 SALEM GENERATING STATION - UNITS 1 AND 2 EFFLUENTS AND WASTE DISPOSAL ANNUAL REPORT JULY - DECEMBER 2005 SOLID WASTE AND IRRADIATED FUEL SHIPMENTS SOLID RADWASTE SHIPPED OFFSITE FOR BURIAL OR DISPOSAL (Not Irradiated Fuel)

SGS 6-Month Est. Total 1 A. Type of Waste (Class A)

Units' Period Error

a.

Spent Resins, Filters, Sludge, m3 5.83E+00 25%

Evaporator Bottoms Ci 1.80E+00

b. Dry Compressible Waste, m'

3.62E+02 25%

Contaminated Equipment Ci 5.67E-01

c. Irradiated Components m3 0.OOE+00 25%

Ci 0.OOE+00

d. Others - Ul CRDM, & Head m3 7.28E+02 25%

U2 CRDM, & Head Ci 4.92E+01 1 Volumes are measured, activities are estimated 2A. Estimate of Major Nuclide Composition (>1%) - SGS Resins Irradiated Components Nuclides Ci Ci Tritium 1.30 2.36E-02 0.00 0.00E+00 Carbon-14 9.73 1.77E-01 0.00 0.OOE+00 Iron-55 22.41 4.07E-01 0.00 0.OOE+00 Cobalt-60 9.90 1.80E-01 0.00 0.00E+00 Nickel-63 39.20 7.12E-01 0.00 0.00E+00 Antimony-125 3.51 6.38E-02 0.00 0.OOE+00 Cesium-134 3.77 6.85E-02 0.00 0.OOE+00 Cesium-137 9.02 1.64E-01 0.00 0.OOE+00 DAW CRDMs, & Heads Nuclides Ci Ci Tritium 3.52 2.01E-02 0.00 0.OOE+00 Chromium-51 0.00 0.OOE+00 1.41 7.24E-01 Manganese-54 1.18 6.74E-03 0.00 0.OOE+00 Iron-55 35.94 2.05E-01 72.81 3.74E+01 Cobalt-58 26.55 1.51E-01 8.23 4.23E+00 Cobalt-60 4.49 2.56E-02 5.05 2.60E+00 Nickel-63 13.08 7.45E-02 8.32 4.28E+00 Niobium-95 1.14 6.48E-03 0.00 0.OOE+00 Cesium-134 5.26 2.99E-02 0.00 0.OOE+00 Cesuim-137 8.33 4.74E-02 0.00 0.OOE+00 48

2005 SGS AND HCGS RADIOACTIVE EFFLUENTS RELEASE REPORT TABLE 3A-2 (Continued)

L SALEM GENERATING STATION - UNITS 1 AND 2 EFFLUENTS AND WASTE DISPOSAL ANNUAL REPORT JULY - DECEMBER 2005 U

SOLID WASTE AND IRRADIATED FUEL SHIPMENTS SOLID RADWASTE SHIPPED OFFSITE FOR BURIAL OR DISPOSAL L

3A. Solid Waste Disposal (Class A or less) - SGS Number of Mode of Shipments Transportation Destination Tvpe of Containers 1

Truck Barnwell, SC HIC 21 Truck Memphis, TN Metal U

U

2005 SGS AND HCGS RADIOACTIVE EFFLUENTS RELEASE REPORT TABLE 3A-2 (continued)

SALEM GENERATING STATION - UNITS 1 AND 2 EFFLUENTS AND WASTE DISPOSAL ANNUAL REPORT JULY - DECEMBER 2005 SOLID WASTE AND IRRADIATED FUEL SHIPMENTS SOLID RADWASTE SHIPPED OFFSITE FOR BURIAL OR DISPOSAL (Not Irradiated Fuel)

SGS 1 B. Type of Waste (Class B)

Unitsi 6-Month Est. Total Period Error

a.

Spent Resins, Filters, m3 1.02E+01 25%

Evaporator Bottoms Ci 1.22E+02

b. Dry Compressible Waste, m3 0.00E+00 25%

Contaminated Equipment Ci 0.OOE+00

c. Irradiated Components m3 0.OOE+00 25%

Ci 0.OOE+00

d. Others M3 0.00E+00 25%

Ci 0.00E+00 1 Volumes are measured, activities are estimated 2B. Estimate of Major Nuclide Composition (>1%) - SGS Resins I Irradiated Components Ci Nuclides Iron-55 Cobalt-60 Nickel-63 Cesium-134 Cesium-137 Ci l

3.44 8.38 49.88 6.93 31.04 4.23E+00 1.03E+01 6.12E+01 8.51E+00 3.81E+01 0.00 0.00 0.00 0.00 0.00 0.OOE+00 0.00E+00 0.OOE+00 0.OOE+00 0.OOE+00 3B. Solid Waste Disposal (C lass B) - SGS Number of Shipments 3

Mode of Transportation Truck Destination Barnwell, SC Tvpe of Containers HIC 50

L 2005 SGS AND HCGS RADIOACTIVE EFFLUENTS RELEASE REPORT TABLE 3B-1 HOPE CREEK GENERATING STATION EFFLUENTS AND WASTE DISPOSAL ANNUAL REPORT JANUARY - JUNE 2005 SOLID WASTE AND IRRADIATED FUEL SHIPMENTS SOLID RADWASTE SHIPPED OFFSITE FOR BURIAL OR DISPOSAL (Not irradiated Fuel)

I L

L HCGS 6-Month Est. Total 1 A.

Type of Waste (Class A)

UnitsI Period Error

a.

Spent Resins, Filters, Sludge, m3 0.OOE+00 25%

Evaporator Bottoms Ci 0.OOE+00

b. Dry Compressible Waste, m3 3.26E+02 25%

Contaminated Equipment Ci 6.35E-01

c. Irradiated Components, mr 0.OOE+00 25%

Control Rods Ci 0.OOE+00

d. Others m3 0.OOE+00 25%

Ci 0.OOE+00 1 Volumes are measured, activities are estimated L

U U

2A. Estimate of Major Nuclide Composition (>1%) (Class A) - HCGS DAW Nuclides Ci Chromium-51 18.15 1.15E-01 Manganese-54 1.94 1.23E-02 Iron-55 54.70 3.48E-01 Cobalt-58 1.52 9.66E-03 Iron-59 13.63 8.67E-02 Cobalt-60 3.62 2.30E-02 Nickel-63 1.97 1.26E-02 Zinc-65 4.38 2.78E-02 3A. Solid Waste Disposal (Class A) - HCGS L

L LU L

Number of Shipments 6

Mode of Transportation Truck Destination Memphis, TN Type of Containers Metal L

51 L

2005 SGS AND HCGS RADIOACTIVE EFFLUENTS RELEASE REPORT TABLE 3B-2 HOPE CREEK GENERATING STATION EFFLUENTS AND WASTE DISPOSAL ANNUAL REPORT JULY -DECEMBER 2005 SOLID WASTE AND IRRADIATED FUEL SHIPMENTS SOLID RADWASTE SHIPPED OFFSITE FOR BURIAL OR DISPOSAL (Not Iradiated Fuel)

HCGS 1 A. Type of Waste (Class A)

Units' 6-Month Period Est. Total Error

a.

Spent Resins, Filters, m3 1.22E+02 25%

Evaporator Bottoms Ci 3.97E+02

b. Dry Compressible Waste, m3 2.17E+02 25%

Contaminated Equipment Ci 1.88E+00

c. Irradiated Components, m'

0.OOE+00 25%

Control Rods Ci 0.OOE+00

d. Others - Contaminated Oil m3 7.25E+01 25%

Ci 8.96E-02 1 Volumes are measured, activities are estimated 2A. Estimate of Major Nuclide Composition (>1%) (Class A) - HCGS Resins Irradiated Components Ci Nuclides Manganese-54 Iron-55 Cobalt-58 Cobalt-60 Nuclides Chromium-51 Manganese-54 Iron-55 Iron-59 Cobalt-60 Nickel-63 Zn-65 Ci 6.70 2.69E+01 0.00 0.OOE+00 84.87 3.41E+02 0.00 0.00E+00 1.26 5.07E+00 0.00 0.00E+00 6.00 2.39E+01 0.00 0.00E+00 DAW Contaminated Oil I

Ci Ci 16.13 2.07 61.21 11.00 4.44 1.25 3.08 3.05E-01 3.92E-02 1.16E+00 2.08E-01 8.40E-02 2.35E-02 5.82E-02 16.13 2.07 61.21 11.00 4.44 1.25 3.08 1.46E-02 1.87E-03 5.53E-02 9.93E-03 4.01E-03 1.12E-03 2.78E-03 52

2005 SGS AND HCGS RADIOACTIVE EFFLUENTS RELEASE REPORT TABLE 3B-2 HOPE CREEK GENERATING STATION EFFLUENTS AND WASTE DISPOSAL ANNUAL REPORT JULY - DECEMBER 2005 SOLID WASTE AND IRRADIATED FUEL SHIPMENTS SOLID RADWASTE SHIPPED OFFSITE FOR BURIAL OR DISPOSAL L

3A. Solid Waste Disposal (Class A) - HCGS Number of Mode of Shipments Transportation Destination Tvpe of Containers 16 Truck Barnwell, SC HIC 6

Truck Memphis, TN Metal L

L L

53 C

L

2005 SGS AND HCGS RADIOACTIVE EFFLUENTS RELEASE REPORT TABLE 4A-1 SALEM GENERATING STATION - UNIT 1 EFFLUENTS AND WASTE DISPOSAL ANNUAL REPORT JANUARY - JUNE 2005

SUMMARY

SHEET FOR RADIOACTIVE EFFLUENTS RELEASED IN A BATCH MODE BATCH RELEASES ONLY

1. Dates:

January 1, 2005 - March 31, 2005

2. Type of release:

Gaseous

3. Number of releases during quarter:

224

4. Total time duration for all releases of type listed above:

1.63E+04 Min.

5. Maximum duration for release of type listed above:

1.22E+02 Min.

6. Average duration for release of type listed above:

7.28E+01 Min.

7. Minimum duration for release of type listed above:

1.OOE+01 Min.

8. Average stream flow (dilution flow) during period of release:

N/A BATCH RELEASES ONLY

1. Dates:

April 1, 2005 - June 30, 2005

2. Type of release:

Gaseous

3. Number of releases during quarter:

202

4. Total time duration for all releases of type listed above:

1.50E+04 Min.

5. Maximum duration for release of type listed above:

1.59E+02 Min.

6. Average duration for release of type listed above:

7.41E+01 Min.

7. Minimum duration for release of type listed above:

4.50E+01 Min.

8. Average stream flow (dilution flow) during period of release:

N/A 54

2005 SGS AND HCGS RADIOACTIVE EFFLUENTS RELEASE REPORT TABLE 4A-1 (Continued)

SALEM GENERATING STATION - UNIT 1 EFFLUENTS AND WASTE DISPOSAL ANNUAL REPORT JULY - DECEMBER 2005

SUMMARY

SHEET FOR RADIOACTIVE EFFLUENTS RELEASED IN A BATCH MODE BATCH RELEASES ONLY

1. Dates:

July 1, 2005 - September 30, 2005

2. Type of release:

Gaseous

3. Number of releases during quarter:

175

4. Total time duration for all releases of type listed above:

1.25E+04 Min.

5. Maximum duration for release of type listed above:

1.96E+02 Min.

6. Average duration for release of type listed above:

7.17E+01 Min.

7. Minimum duration for release of type listed above:

1.50E+01 Min.

8. Average stream flow (dilution flow) during period of release:

N/A BATCH RELEASES ONLY

1. Dates:

October 1, 2005 - December 31, 2005

2. Type of release:

Gaseous

3. Number of releases during quarter:

161

4. Total time duration for all releases of type listed above:

1.36E+04 Min.

5. Maximum duration for release of type listed above:

1.91E+02 Min.

6. Average duration for release of type listed above:

8.46E+01 Min.

7. Minimum duration for release of type listed above:

3.OOE-02 Min.

8. Average stream flow (dilution flow) during period of release:

N/A 55

2005 SGS AND HCGS RADIOACTIVE EFFLUENTS RELEASE REPORT TABLE 4A-2 SALEM GENERATING STATION - UNIT 2 EFFLUENTS AND WASTE DISPOSAL ANNUAL REPORT JANUARY - JUNE 2005

SUMMARY

SHEET FOR RADIOACTIVE EFFLUENTS RELEASED IN A BATCH MODE BATCH RELEASES ONLY

1. Dates:

January 1, 2005 - March 31, 2005

2. Type of release:

Gaseous

3. Number of releases during quarter:

184

4. Total time duration for all releases of type listed above:

1.33E+04 Min.

5. Maximum duration for release of type listed above:

1.72E+02 Min.

6. Average duration for release of type listed above:

7.21E+01 Min.

7. Minimum duration for release of type listed above:

3.OOE+01 Min.

8. Average stream flow (dilution flow) during period of release:

N/A BATCH RELEASES ONLY

1. Dates:

April 1, 2005 - June 30, 2005

2. Type of release:

Gaseous

3. Number of releases during quarter:

96

4. Total time duration for all releases of type listed above:

7.14E+03 Min.

5. Maximum duration for release of type listed above:

3.43E+02 Min.

6. Average duration for release of type listed above:

7.44E+01 Min.

7. Minimum duration for release of type listed above:

3.50E+01 Min.

8. Average stream flow (dilution flow) during period of release:

N/A 56

2005 SGS AND HCGS RADIOACTIVE EFFLUENTS RELEASE REPORT TABLE 4A-2 (Continued)

SALEM GENERATING STATION - UNIT 2 EFFLUENTS AND WASTE DISPOSAL ANNUAL REPORT JULY - DECEMBER 2005 L

SUMMARY

SHEET FOR RADIOACTIVE EFFLUENTS RELEASED IN A BATCH MODE L

Li BATCH RELEASES ONLY

1. Dates:

July 1, 2005 - September 30, 2005

2. Type of release:

Gaseous

3. Number of releases during quarter:

104 L

4. Total time duration for all releases of type listed above:

6.63E+03 Min.

L

5. Maximum duration for release of type listed above:

1.40E+02 Min.

6. Average duration for release of type listed above:

6.37E+01 Min.

U

7. Minimum duration for release of type listed above:

3.OOE+01 Min.

L

8. Average stream flow (dilution flow) during period of release:

N/A C

BATCH RELEASES ONLY

1. Dates:

October 1, 2005 - December 31, 2005 L

2. Type of release:

Gaseous L

3. Number of releases during quarter:

106

4. Total time duration for all releases of type listed above:

7.99E+03 Min.

°

5. Maximum duration for release of type listed above:

4.90E+02 Min.

6. Average duration for release of type listed above:

7.54E+01 Min.

7. Minimum duration for release of type listed above:

4.OOE+01 Min.

8. Average stream flow (dilution flow) during period of release:

N/A 57

2005 SGS AND HCGS RADIOACTIVE EFFLUENTS RELEASE REPORT TABLE 4A-3 HOPE CREEK GENERATING STATION EFFLUENTS AND WASTE DISPOSAL ANNUAL REPORT JANUARY - JUNE 2005

SUMMARY

SHEET FOR RADIOACTIVE EFFLUENTS RELEASED IN A BATCH MODE 1.

2.

3, 4,

5' 6.

7' 8.

BATCH RELEASES ONLY

. Dates:

January 1, 2005 -

. Type of release:

I Number of releases during quarter:

I Total time duration for all releases of type listed above:

I Maximum duration for release of type listed above:

. Average duration for release of type listed above:

Minimum duration for release of type listed above:

  • Average stream flow (dilution flow) during period of release:

March 31, 2005 Gaseous 3

6.86E+03 4.79E+03 2.29E+03 4.83E+02 N/A Min.

Min.

Min.

Min.

BATCH RELEASES ONLY

1. Dates:

April 1, 2005-June 30, 2005

2. Type of release:

Gaseous

3. Number of releases during quarter:

3

4. Total time duration for all releases of type listed above:

5.48E+03 Min.

5. Maximum duration for release of type listed above:

3.56E+03 Min.

6. Average duration for release of type listed above:

1.83E+03 Min.

7. Minimum duration for release of type listed above:

4.86E+02 Min.

8. Average stream flow (dilution flow) during period of release:

N/A 58

2005 SGS AND HCGS RADIOACTIVE EFFLUENTS RELEASE REPORT TABLE 4A-3 (Continued)

HOPE CREEK GENERATING STATION EFFLUENTS AND WASTE DISPOSAL ANNUAL REPORT JULY - DECEMBER 2005

SUMMARY

SHEET FOR RADIOACTIVE EFFLUENTS RELEASED IN A BATCH MODE 1

2 3

4 5

6, 7,

8, BATCH RELEASES ONLY

  • Dates:

July 1, 2005-Se

. Type of release:

  • Number of releases during quarter:
  • Total time duration for all releases of type listed above:
  • Maximum duration for release of type listed above:

I Average duration for release of type listed above:

I Minimum duration for release of type listed above:

I Average stream flow (dilution flow) during period of release:

.ptember 30, 2005 Gaseous 3

7.83E+03 5.77E+03 2.61E+03 3.46E+02 N/A Min.

Min.

Min.

Min.

BATCH RELEASES ONLY

1. Dates:

October 1, 2005-December 31, 2005

2. Type of release:

Gaseous

3. Number of releases during quarter:

0

4. Total time duration for all releases of type listed above:

0.OOE+00 Min

5. Maximum duration for release of type listed above:

0.OOE+00 Min

6. Average duration for release of type listed above:

0.OOE+00 Min

7. Minimum duration for release of type listed above:

0.OOE+00 Min

8. Average stream flow (dilution flow) during period of release:

N/A 59

2005 SGS AND HCGS RADIOACTIVE EFFLUENTS RELEASE REPORT TABLE 4B-1 SALEM GENERATING STATION - UNIT 1 EFFLUENTS AND WASTE DISPOSAL ANNUAL REPORT JANUARY - JUNE 2005

SUMMARY

SHEET FOR RADIOACTIVE EFFLUENTS RELEASED IN A BATCH MODE 1I 2

3 4

5 6

7, 8,

BATCH RELEASES ONLY

  • Dates:

January 1, 2005 - M

  • Type of release:
  • Number of releases during quarter:
  • Total time duration for all releases of type listed above:
  • Maximum duration for release of type listed above:
  • Average duration for release of type listed above:

. Minimum duration for release of type listed above:

  • Average stream flow (dilution flow) during period of release:

larch 31, 2005 Liquid 30 3.94E+03 4.93E+02 1.3 1E+02 5.00E-02 8.89E+05 Min Min Min Min GPM 1.

2, 3.

4.

5.

6.

7.

8.

BATCH RELEASES ONLY

. Dates:

April 1, 2005 Type of release:

Number of releases during quarter:

Total time duration for all releases of type listed above:

Maximum duration for release of type listed above:

Average duration for release of type listed above:

Minimum duration for release of type listed above:

Average stream flow (dilution flow) during period of release:

5 - June 30, 2005 Liquid 25 5.89E+03 6.30E+02 2.35E+02 2.OOE-02 9.06E+05 Min.

Min.

Min.

Min.

GPM 60

2005 SGS AND HCGS RADIOACTIVE EFFLUENTS RELEASE REPORT, TABLE 4B-1 (Continued)

L SALEM GENERATING STATION - UNIT 1 EFFLUENTS AND WASTE DISPOSAL ANNUAL REPORT JULY - DECEMBER 2005 L

SUMMARY

SHEET FOR RADIOACTIVE EFFLUENTS RELEASED IN A BATCH MODE L

BATCH RELEASES ONLY

1. Dates:

July 1, 2005 - September 30, 2005 L

2. Type of release:

Liquid

3. Number of releases during quarter:

18 L

4. Total time duration for all releases of type listed above:

2.75E+03 Min.

L

5. Maximum duration for release of type listed above:

3.99E+02 Min.

6. Average duration for release of type listed above:

1.53E+02 Min.

7. Minimum duration for release of type listed above:

4.20E-01 Min.

L

8. Average stream flow (dilution flow) during period of release:

9.54E+05 GPM C

BATCH RELEASES ONLY

1. Dates:

October 1, 2005 - December 31, 2005 U

2. Type of release:

Liquid U

3. Number of releases during quarter:

24

4. Total time duration for all releases of type listed above:

5.07E+03 Min.

5. Maximum duration for release of type listed above:

3.32E+02 Min.

L

6. Average duration for release of type listed above:

2.1 IE+02 Min.

7. Minimum duration for release of type listed above:

8.OOE-02 Min.

8. Average stream flow (dilution flow) during period of release:

6.72E+05 GPM U

61

2005 SGS AND HCGS RADIOACTIVE EFFLUENTS RELEASE REPORT TABLE 4B-2 SALEM GENERATING STATION - UNIT 2 EFFLUENTS AND WASTE DISPOSAL ANNUAL REPORT JANUARY - JUNE 2005

SUMMARY

SHEET FOR RADIOACTIVE EFFLUENTS RELEASED IN A BATCH MODE 3.

4' 5.

6.

7.

8.

BATCH RELEASES ONLY Dates:

January 1, 2005 - M Type of release:

Number of releases during quarter:

Total time duration for all releases of type listed above:

Maximum duration for release of type listed above:

Average duration for release of type listed above:

Minimum duration for release of type listed above:

Average stream flow (dilution flow) during period of release:

Larch 31,2005 Liquid 8

2.30E+03 4.1OE+02 2.88E+02 1.82E+02 8.75E+05 Min Min Min Min GP M

BATCH RELEASES ONLY

1. Dates:

April 1, 2005 - June 30, 2005

2. Type of release:

Liquid

3. Number of releases during quarter:

25

4. Total time duration for all releases of type listed above:

8.72E+03 Min.

5. Maximum duration for release of type listed above:

9.05E+02 Min.

6. Average duration for release of type listed above:

3.49E+02 Min.

7. Minimum duration for release of type listed above:

2.00E+00 Min.

8. Average stream flow (dilution flow) during period of release:

6.13E+05 GPM 62

2005 SGS AND HCGS RADIOACTIVE EFFLUENTS RELEASE REPORT TABLE 4B-2 (Continued)

SALEM GENERATING STATION - UNIT 2 EFFLUENTS AND WASTE DISPOSAL ANNUAL REPORT JULY - DECEMBER 2005

SUMMARY

SHEET FOR RADIOACTIVE EFFLUENTS RELEASED IN A BATCH MODE BATCH RELEASES ONLY

1. Dates:

July 1, 2005 - September 30, 2005

2. Type of release:

Liquid

3. Number of releases during quarter:

7

4. Total time duration for all releases of type listed above:

1.92E+03 Min.

5. Maximum duration for release of type listed above:

3.41E+02 Min.

6. Average duration for release of type listed above:

2.74E+02 Min.

7. Minimum duration for release of type listed above:

2.23E+02 Min.

8. Average stream flow (dilution flow) during period of release:

9.37E+05 GPM BATCH RELEASES ONLY

1. Dates:

October 1, 2005 - December 31, 2005

2. Type of release:

Liquid

3. Number of releases during quarter:

7

4. Total time duration for all releases of type listed above:

1.72E+03 Min.

5. Maximum duration for release of type listed above:

3.04E+02 Min.

6. Average duration for release of type listed above:

2.46E+02 Min.

7. Minimum duration for release of type listed above:

1.37E+02 Min.

8. Average stream flow (dilution flow) during period of release:

9.1 OE+05 GPM 63

2005 SGS AND HCGS RADIOACTIVE EFFLUENTS RELEASE REPORT TABLE 4B-3 HOPE CREEK GENERATING STATION EFFLUENTS AND WASTE DISPOSAL ANNUAL REPORT JANUARY - JUNE 2005

SUMMARY

SHEET FOR RADIOACTIVE EFFLUENTS RELEASED IN A BATCH MODE BATCH RELEASES ONLY

1. Dates:

January 1, 2005-March 31, 2005

2. Type of release:

Liquid

3. Number of releases during quarter:

71

4. Total time duration for all releases of type listed above:

4.98E+03 Min.

5. Maximum duration for release of type listed above:

9.22E+01 Min.

6. Average duration for release of type listed above:

7.02E+01 Min.

7. Minimum duration for release of type listed above:

3.OOE+01 Min.

8. Average stream flow (dilution flow) during period of release:

3.05E+04 GPM BATCH RELEASES ONLY

1. Dates:

April 1, 2005-June 30, 2005

2. Type of release:

Liquid

3. Number of releases during quarter:

62

4. Total time duration for all releases of type listed Above:

3.91E+03 Min.

5. Maximum duration for release of type listed above:

8.50E+01 Min.

6. Average duration for release of type listed above:,

6.31E+01 Min.

7. Minimum duration for release of type listed above:

2.OOE+01 Min.

8. Average stream flow (dilution flow) during period of release:

3.12E+04 GPM 64

2005 SGS AND HCGS RADIOACTIVE EFFLUENTS RELEASE REPORT TABLE 4B-3 (Continued)

HOPE CREEK GENERATING STATION EFFLUENTS AND WASTE DISPOSAL ANNUAL REPORT JULY - DECEMBER 2005

SUMMARY

SHEET FOR RADIOACTIVE EFFLUENTS RELEASED IN A BATCH MODE BATCH RELEASES ONLY

1. Dates:

July 1, 2005-September 30, 2005

2. Type of release:

Liquid

3. Number of releases during quarter:

71

4. Total time duration for all releases of type listed above:

5.04E+03 Min.

5. Maximum duration for release of type listed above:

8.60E+01 Min.

6. Average duration for release of type listed above:

7.09E+01 Min.

7. Minimum duration for release of type listed above:

3.03E+01 Min.

8. Average stream flow (dilution flow) during period of release:

4.16E+04 GPM BATCH RELEASES ONLY

1. Dates:

October 1, 2005-December 31, 2005

2. Type of release:

Liquid

3. Number of releases during quarter:

7

4. Total time duration for all releases of type listed above:

3.02E+02 Min.

5. Maximum duration for release of type listed above:

7.20E+01 Min.

6. Average duration for release of type listed above:

4.32E+01 Min.

7. Minimum duration for release of type listed above:

2.50E+01 Min.

8. Average stream flow (dilution flow) during period of release:

3.13E+04 GPM 65

2005 SGS AND HCGS RADIOACTIVE EFFLUENTS RELEASE REPORT APPENDIX A METEOROLOGICAL DATA

2005 SGS AND HCGS RADIOACTIVE EFFLUENTS RELEASE REPORT Lapse Rate Wind Distributions 300-33 Foot 1/2005 - 3/2005

C, r

C U-F O

O ARTIFICIAL ISLAND 01/05-03/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 30 FT DELTA T: (300-33FT)

LAPSE RATE:

LE -1.9 DEG C/1OOM CLASS A WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0:0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

2 0

0 0

0 0

0 0

0 0

3 4

3 9

1 0.0 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.2 0.1 0.4 0.0 0

0 0

0 0

0 0

1 0

0 0

0 1

0 16 0

0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.7 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 3

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

2 0

0 0

0 0

1 0

0 0

3 5

3 28 1

0.0 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.2 0.1 1.3 0.0 0

0.0 0

0.0 0

0.0 22 1.0 18 0.8 0.1 0

0.0 43 2.0 MEAN WIND SPEED:

13.4 MISSING:

0

ARTIFICIAL ISLAND 01/05-03/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 30 FT DELTA T: (300-33FT)

LAPSE RATE: -1.8 TO -1.7 DEG C/10OM CLASS B WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW

-W mmw NW NNW 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 o

o.o 0

0.0 o

o.o 0

0.0 0

0.0 SUM PERCENT 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 SUM PERCENT 1

0.0 1

0.0 0

0.0 1

0.0 0

0.0 1

0.0 0

0.0 0

0.0 0

0.0 0

0.0 2

0.1 0

p.0 1

bie 0

0.0 0

0.0 0

0.0 SUM PERCENT 6

0.3 8

0.4 3

0.1 0

0.0 0

0.0 0

0.0 1

0.0 0

0.0 0

0.0 0

0.0 1

0.0 0

0.0 5

0.2 2

0d.

6 0.3 5

0.2 SUM PERCENT 3

0.1 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 O

0.0 0

0.0 0

0.0 3

0.1 5

0.2 3

0.1 14 0.7 5

0.2 SUM PERCENT 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0-.0 0

0.0 0

0.0 0

0.0 0

0.0 I

0.1 O

0.0 SUM PERCENT 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 10 0.5 9

0.4 3

0.1 1

0.0 0

0.0 1

0.0 1

0,0 1

0.0 0

0.0 0

0.0 3

0.1 3

0.1 11 0.5 8

0.4 21 1.0 10 0.5 0

0.0 0

0'.0 7

0.3 37 1.7 34 1 6 4

0.Z 0

0.0 82 3.8 MEAN WIND SPEED:

12.7 MISSING:^

0 C7 r-

=

7 rr r-ci rr c-t r=

r=

r~-

rzJ I

or 7?

l rl W-j tj--

_7

=?

r-'-

f 7-ARTIFICIAL ISLAND 01/05-03/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 30 FT DELTA T: (300-33FT)

LAPSE RATE: -1.6 TO -1.5 DEG C/1OOM CLASS C WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0

0. 0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 4

3 6

0 1

0 1

0 0

0 2

2 0

2 4

7 0.2 0.1 0.3 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.0 0.1 0.2 0.3 8

6 4

1 0

0 0

0 0

0 0

5 5

2 8

13 0.4 0.3 0.2 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.2 0.2 0.1 0.4 0.6 1

2 1

0 0

0 0

2 0

0 0

0 1

3 7

2 0.0 0.1 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0.0 0.0 0.0 0.0 0.1 0.3 0.1 0

0 0

0 0

0 0

0 0

0 0

0 1

1 2

1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 13 1 1 11 I

1 0

1 2

0 0

2 7

7 8

21 23 0.6 0.5 0.5 0.0 0.0 0.0 0.0 0.1 0.0 0.0 0.1 0.3 0.3 0.4 1.0 1.1 0

0.0 0

0.0 32 1.5 52 2.4 19 0.9 5

0.2 0

0.0 108 5.0 MEAN WIND SPEED:

10.3 MISSING:

0

ARTIFICIAL ISLAND 01/05-03/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 30 FT DELTA T: (300-33FT)

LAPSE RATE: -1.4 TO -0.5 DEG C/1OOM CLASS D WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW zW Ws NNW 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 25 1.2 2

0.1 28 1.3 2

0.1 36 1.7 8

0.4 29 1.3 1

0.0 8

0.4 0

0.0 10 0.5 1

0.0 10 0.5 6

0.3 15 0.7 3

0.1 7

0.3 3

0.1 6

0.3 3

0.1 7

0.3 4

0.2 12 0.6 2

0.1 9

0.4 2

0.1 19 0.9 3

0.1 14 0.7 3

0.1 22 1.0 43 2.0 10 0.5 38 1.8 7

0.3 31 1.4 6

0.3 10 0.5 5

0.2 1

0.0 0

0.0 8

0.4 0

0.0 14 0.7 14 0.7 18 0.8 11 0.5

-6 0.3 4

0.2 3

0.1 1

0.0 6

0.3 0

0.0 29 1.3 7

0.3 29 1.3 13 0.6 29 1.3 38 1.8 45 2.1 49 2.3 26 1.2 17 0.8 336 15.6 182 8.5 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 2

0.1 0

0.0 0

0.0 9

0.4 20 0.9 7

7 0.3 38 1-8 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 1

0.0 1

0.0 78 3.6 75 3.5 75 3.5 52 2.4 10 0.5 19 0.9 39 1.8 50 2.3 20 0.9 13 0.6 18 0.8 52 2.4 53 2.5 98 4.6 132 6.1 76 3.5 0

0.0 43 2-0 257 12_D 4

0.2 860 40.0 MEAN WIND SPEED:

9.9 MISSING:;

3 rc rzc r= r7 r:

r wr r-l r

r=

re r:

r=

r-3 r

j gm V"

C l

1,

]

I" O

t3 ARTIFICIAL ISLAND 01/05-03/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND:

30 FT DELTA T: (300-33FT)

LAPSE RATE: -0.4 TO 1.5 DEG C/lOOM CLASS E WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0

0. 0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 9

9 10 8

12 8

6 10 6

6 7

3 3

6 5

10 0.4 0.4 0.5 0.4 0.6 0.4 0.3 0.5 0.3 0.3 0.3 0.1 0.1 0.3 0.2 0.5 42 39 40 15 16 32 16

-16 2

3 10 29 18 31 35 39 2.0 1.8 1.9 0.7 0.7 1.5 0.7 0.7 0.1 0.1 0.5 1.3 0.8 1.4 1.6 1.8 25 4

8 0

0 6

22 4

3 1

2 6

11 29 45 32 1.2 0.2 0.4 0.0 0.0 0.3 1.0 0.2 0.1 0.0 0.1 0.3 0.5 1.3 2.1 1.5 3

0 0

0 1

2 4

3 0

2 1

3 0

1 5

9 0.1 0.0 0.0 0.0 0.0 0.1 0.2 0.1 0.0 0.1 0.0 0.1 0.0 0.0 0.2 0.4 0

0 0

0 0

0 0

0 0

0 0

0 0

0 2

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0

0 0

0 0

1 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 79 52 58 23 29 49 48 33 11 12 20 41 32 67 92 90 3.7 2.4 2.7 1.1 1.3 2.3 2.2 1.5 0.5 0.6 0.9 1.9 1.5 3.1 4.3 4.2 0

0.0 118 5.5 383 17.8 198 9.2 34 1.6 2

0.1 1

0.0 736 34.2 MEAN WIND SPEED:

6.6 MISSING

1

ARTIFICIAL ISLAND 01/05-03/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 30 FT DELTA T: (300-33FT)

LAPSE RATE:

1.6 TO 4.0 DEG C/1OOM CLASS F WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE EN~E E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.p 0

0.0 0

0.0 0

0.0 2

0.1 15 1

0.0 13 3

0.1 11 0

0.0 6

3 0.1 1

1 0.0 2

5 0.2 6

4 0,.2 16 1

0.0 7

2 0.1 3

1 0.0 7

0 0.0 7

1 0Q.0

1
1.

0,.0 2

0.1 15 3

0.1 11 0.7 13 0.6 0.6 2

0.1 0.5 2

0.1 0.3 0

0.0 0.0 0

0.0 0.1 0

0.0 0.3 11 0.5 0.7 1

0.0 0.3 2

0.1 0.1 1

0.0 0.3 10 0.5 0.3 6

0,.3 0.0 0

0.'0 02 0

0.0 0.7

.0 90.0

0.5 6

0.3 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 3

0.1 0

0.0 3

0.1 6

0.3 1

0.0 0

0.0 0

0.'0 0

0.0 0

'0,.0 0

-0.0 0

0.0 0

0,.0 0

0.0 0

0.0 0

0.0 0

0.0 3

0.1 0

0,.0 4

0_2 0

0.0 0

0.0 0

0.0 0

0.0 0'

0r. 0 O.0

.0.

0 0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 30 1.4 16 0.7 16 0.7 6

0.3 4

0.2 3

0.1 28 1.3 21 1.0 17 0.8 12 0.6 19 0.9 13 0.6 2

0.1 5

0.2 17 0.8 20 0.9 0

0.0 30 L.4 125 5.8 54 2.5 13 0.6 i

7 0.3 0

0.0 229 10.7 MEAN WIND SPEED:

7.0 MISSING_-

0 r r rc t r r n p

rhirr7 r rr r A, r1z C AA-r n

w-7 r7 r--3 an s--7 r--r" nr-n

[1r--r7o ARTIFICIAL ISLAND 01/05-03/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 30 FT DELTA T: (300-33FT)

LAPSE RATE:

GT 4.0 DEG C/lOOM CLASS G WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5

3. 6-7.5
7. 6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 1

0 0

2 2

5 3

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 3

10 1

0 0

0 14 8

0 0

0 3

0 0

0 6

0.1 0.5 0.0 0.0 0.0 0.0 0.7 0.4 0.0 0.0 0.0 0.1 0.0 0.0 0.0 0.3 2

2 0

0 0

0 14 4

0 0

0 1

0 0

0 0

0.1 0.1 0.0 0.0 0.0 0.0 0.7 0.2 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 8

2 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.4 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 1

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0' 0.0 0.0 0.0 0.0 0.0 5

12 2

0 0

2 38 19 4

0 0

4 0

0 0

6 0.2 0.6 0.1 0.0 0.0

0. 1 1.8 0.9 0.2 0.0 0.0 0.2 0.0 0.0 0.0 0.3 0

0.0 13 0.6 45 2.1 23 1.1 10 0.5 0.0 0

0.0 92 4.3 MEAN WIND SPEED:

7.6 MISSING

0

ARTIFICIAL ISLAND 01/05-03/05 JOINT DISTRIBUTION-OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 30 ET DELTA T: (300-33FT)

ALL STABILITY CLASSES WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 11 12 16 16 16 11 14 25 13 11 11 7

6 9

10 16 0.5 0.6 0.7 0.7 0.7 0.5 0.7 1.2 0.6 0.5 0.5 0.3 0.3 0.4 0.5 0.7 90 94 94 51 26 45 47 55 16 12 28 53 29 56 68 85 4.2 4.4 4.4 2.4 1.2 2.1 2.2 2.6 0;7 0.6 1.3 2.5 1.3 2.6 3.2 4.0-97 62 48 11 1

14 62 27 11 5

19 50 54 65 83 4.5 2.9 2.2 0.5 0.0 0.7 2.9 1.3 0.5 0.2 0.9 2.3 2.5 3.0 5.3 3.9 SUM PERCENT 17 0.8 9

0.4 7

0.3 5

0.2 1

0.0 2

0.1 29 1.3 20 0.9 I7 0.3 9

0.4 2

0.1 13 0.6 20 0,9 45>

2'.1i 91 4.2 33-1.5 SUM PERCENT SUM PERCENT 0

0 0

0 0

0 3

0 5

0 2

0 1

13 28 8

0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0.2 0.0 0.1

0. 0 0.0 0.6 1.3 0.4 0

0 0

0 0

2 0

0 0

0 0

0 0

1 1

1 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 215 177 165 83 44 74 155 127 52 37 62 123 110 189 311 226 10.0 8.2 7.7 3.9 2.0 3.4 7.2 5.9 2.4 1.7 2.9 5.7 5.1 8.8 14.5 10.5 0

0.0 204 9.5 849 3r.5 722 33.6 310 14-4 60 2.8 5

0.2 2150 100.0 MISSING HOURS:

10 MEAN WIND SPEED:

8.6

-Ci r

r-7 r r r :

r r

.c :

O_

en" 7

r?

C~l IV" V:

C:l ran 7

r__:

lr-or.:7 7

W-ARTIFICIAL ISLAND 01/05-03/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 30 FT DELTA T: (300-33FT)

DIRECTION VS SPEED ONLY WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0.0 11 0.5 90 4.2 97 4.5 17 0.8 0

0.0 12 0.6 94 4.4 62 2.9 9

0.4 0

0.0 16 0.7 94 4.4 48 2.2 7

0.3 0

0.0 16 0.7 51 2.4 11 0.5 5

0.2 0

0.0 16 0.7 26 1.2 1

0.0 1

0.0 0

0.0 11 0.5 45 2.1 14 0.7 2

0.1 0

0.0 14 0.7 47 2.2 63 2.9 29 1.3 0

0.0 25 1.2 56 2.6 27 1.3 20 0.9 0

0.0 14 0.7 16 0.7 11 0.5 7

0.3 0

0.0 11 0.5 12 0.6 5

0.2 9

0.4 0

0.0 11 0.5 28 1.3 19 0.9 2

0.1 0

0.0 7

0.3 53 2.5 50 2.3 13 0.6 0

0.0 6

0.3 29 1.3 54 2.5 20 0.9 0

0.0 9

0.4 56 2.6 65 3.0 45 2.1 0

0.0 10 0.5 68 3.2 113 5.2 91 4.2 0

0.0 16 0.7 85 3.9 83 3.9 33 1.5 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 3

0.1 0

0.0 5

0.2 0

0.0 2

0.1 0

0.0 1

0.0 13 0.6 28 1.3 8

0.4 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 2

0.1 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 1

0.0 1

0.0 215 10.0 177 8.2 165 7.7 83 3.9 44 2.0 74 3.4 156 7.2 128 5.9 53 2.5 37 1.7 62

.2.9 123 5.7 110 5.1 189 8.8 311 14.4 226 10.5 0

0.0 205 9.5 850 39.5 723 33.6 310 14.4 60 2.8 5

0.2 2153 100.0 MISSING HOURS:

7 MEAN WIND SPEED:

8.6

ARTIFICIAL ISLAND 01/05-03/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 150 FT DELTA T: (300-33FT)

LAPSE RATE:

LE -1.9 DEG C/1OOM CLASS A WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5

7. 6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT N

NNE NE ENE E

ESE SE SSS S

SSW SW WSW W

%W~i NW NNW 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 O

0.0 0

0.0 0

0.0 SUM PERCENT 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 SUM PERCENT 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0

-20

^0.0 0

0.0 0

0.0 0

0.0

  • 0 0.0 00
0. 0 o

o.0 o0 0.

SUM PERCENT 0

0.0 1

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0

-o o.0 0

0.0 0

0.0 1

0.0

-2 0.1

  • 3 0.1

-2 0.1 o

0.0 SUM PERCENT 0

0.0 1

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 O-O 0.0 0

0.0 0

0.0 3

0.1 1

0.0 0

0.0 11 0.5

2.

0.1 0

0 0

0 0

0 0

1~0 0

0 01 i2-0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.6 0.0 SUM PERCENT SUM PERCENT 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 2

0.1 0

0.0 0

2 0

0 0

0 0 1 1

0 0

0 4

4 3

27 2

0.0 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.2 0.2 0.1 1.3 0.1 0

0.0 0

0.0

'0 00 9

0.4 18 0.8 14 O07 0.1 43 2.0 MEAN WIND SPEED:

16.7 MISSING:

0 3 £nt 1 r,r r -

: t_ r

r : r-r-r r-I

]

3fanC omr3 ? %

ARTIFICIAL ISLAND 01/05-03/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 150 FT DELTA T: (300-33FT)

LAPSE RATE: -1.8 TO -1.7 DEG C/lOOM CLASS B WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5

3. 6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 SUM PERCENT 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 0

0.0 0

0.0 0

0.0 0

0.0 2

0.1 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 2

0.1 4

0.2 1

0.0 1

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 4

0.2 0

0.0 2

0.1 1

0.0 8

0.4 7

0.3 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 0

0.0 0

0.0 0

0.0 1

0.0 0

0.0 4

0.2 2

0.1 5

0.2 7

0.3 SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT 1

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 0

0.0 0

0.0 0

0.0 3

0.1 4

0.2 4

0.2 13 0.6 1

0.0 SUM PERCENT 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 1

0.0 0

0.0 11 0.5 11 0.5 1

0.0 1

0.0 0

0.0 1

0.0 1

0.0 1

0.0 0

0.0 0

0.0 3

0.1 3

0.1 12 0.6 7

0.3 21 1.0 9

0.4 0

0.0 0

0.0 3

0.1 15 0.7 35 1.6 27 1.3 2

0.1 82 3.8 MEAN WIND SPEED:

16.1 MISSING:

0

ARTIFICIAL ISLAND 01/05-03/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 150 FT DELTA T: (300-33FT)

LAPSE RATE: -1.6 TO -1.5 DEG C/1OOM CLASS C WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 1

1 3

0 0

0 1

0 0

0 2

1 0

0 1

5 0.0 0.0 0.1 0.0 0.0 0.0 0.0 O.:0 0.0 0.0 0.1 0.0 O.0 0.0 0.2 4

9 3

1 0

0 0

0 0

0 0

1 4

3 5

9 0.2 0.4 0.1 0.0 0.0 0.0

-0.0 0.0 0.0.

0.0 00.0

.0.0 0.2 0.1

  • 00.2 0.4 6

3 2

0 0

0 0

0 0

0 0

5 1

1 8

.9 0.3 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.2 0.0 0.0 0.4 O0 4 1

2 0

0 0

0 0

2 0

0 0

0~2 3

4~

1 0.0 0.1 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

1 2

1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.0 12 15 8

1 0

0 1

2 0

0 2

7 7

8 20 25 0.6 0.7 0.4 0.0 0.0 0.0 0.0 0.1 0.0 0.0 0.1 0.3 0.3 0.4 0.9 1.2 0

0.0 0

Q.0 15 0.7 39 1.8 35 I.6 15 Q.7 0.2 108 5.1 MEAN WIND SPEED:

MISSING:.-

13.0 0

V-7; f

-7 V-17n t'

r1 r r77-_

Ur : r -7 rr7 ri:7u r r-i r c7 r

c?

trL-on, ARTIFICIAL ISLAND 01/05-03/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 150 FT DELTA T: (300-33FT)

LAPSE RATE: -1.4 TO -0.5 DEG C/1OOM CLASS D WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 8

0.4 34 1.6 22 1.0 6

0.3 0

0.0 8

0.4 36 1.7 31 1.5 3

0.1 0

0.0 13 0.6 29 1.4 19 0.9 6

0.3 2

0.1 22 1.0 20 0.9 6

0.3 6

0.3 1

0.0 9

0.4 1

0.0 0

0.0 0

0.0 0

0.0 6

0.3 9

0.4 5

0.2 1

0.0 0

0.0 3

0.1 9

0.4 8

0.4 11 0.5 2

0.1 14 0.7 17 0.8 17 0.8 3

0.1 2

0.1 5

0.2 5

0.2 3

0.1 3

0.1 2

0.1 3

0.1 5

0.2 4

0.2 0

0.0 2

0.1 8

0.4 8

0.4 0

0.0 0

0.0 1

0.0 5

0.2 6

0.3 25 1.2 5

0.2 1

0.0 5

0.2 20 0.9 16 0.7 10 0.5 2

0.1 10 0.5 21 1.0 31 1.5 29 1.4 4

0.2 7

0.3 13 0.6 45 2.1 33 1.5 1

0.0 10 0.5 20 0.9 15 0.7 15 0.7 1

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 2

0.1 0

0.0 0

0.0 0

0.0 2

0.1 0

0.0 0

0.0 11 0.5 31 1.5 11 0.5 71 3.3 78 3.7 67 3.1 56 2.6 11 0.5 21 1.0 33 1.5 53 2.5 18 0.8 14 0.7 20 0.9 42 2.0 52 2.4 104 4.9 133 6.2 72 3.4 0

0.0 20 0.9 136 6.4 253 11.9 247 11.6 131 6.1 58 2.7 845 39.6 MEAN WIND SPEED:

13.7 MISSING:

18

ARTIFICIAL ISLAND 01/05-03/05 JOINT DISTRIBUTION OF WIND. DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 150 FT DELTA T: (300-33FT)

LAPSE RATE: -0.4 TO 1.5 DEG C/1OOM CLASS E WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

NNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 2

3 2

1 1

2 3

~1 6

2 3

1 1

0 2

0.1 0.1 0.1 0.0 0.0 0.1 0.1 0.0 0.3 0.1 0.1 0.0 0.0 0,..0 0.0 0.1 11 5

13 13 17 13 9

8 i4 5

11 7

8 11 13 10 0.5 0.2 0.6 0.6 0.8 0.6 0.4 0.4 0.7O 0.2 0.5 0.3 0.4 0.5 0.6 0.5 33 30 44 10 7

20 16 3

0 12 20 11 29 i23 36 1.5 1.4 2.1 0.5 0.3 0.9 0.7

-0.2

'0.1 0.0 0.6 0.9 0.5 1.4 1.1 1.7 27 3

8 0

1 10 21 2

1 5

7 19 58 281 1.3 0.1 0.4 0.0 0.0 0.5 1.0 0.1 0.1 0.1 0.0 0.2 0.3 0.9 2.7 1.3 4

0 0

0 0

2 6

-2 0

0 3

.0 9

0.2 0.0 0.0 0.0 0.0 0.1 0.3 0.1 0.0 0.0 0.0 0.1 0 0 0,0 0.2 0.4 0

0 0

0 0

0 3

1 0

1 1

0 0

0 2

2 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 77 41 67 24 26 47 58 20 26 11 28 36 27 59 101 87

3. 6 1.9 3.1 1.1 1.2 2.2 2.7 0.9 1.2 0.5 1.3 1.7 1.3 2.8 4.7 4.1 0

0.0 30 1.4 168 7 9 299 14.0 196 9.2 32 1.5 10 0.5 735 34.4 MEAN WIND SPEEDz MISSING:

10.7 2

I=C7 C-R Vto C-7" 13 Ir-1r3 1=

l-r z: Ur z r z= r z i r T r T r r

=

r7 fo r 7: e",

3 en-C E

1" Fry r-r7 l= a, hi7U777 W7V ARTIFICIAL ISLAND 01/05-03/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 150 FT DELTA T: (300-33FT)

LAPSE RATE:

1.6 TO 4.0 DEG C/lOOM CLASS F WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5

12. 6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 0

0.0 1

0.0 1

0.0 0

0.0 1

0.0 1

0.0 0

0.0 0

0.0 1

0.0 1

0.0 3

0.1 0

0.0 0

0.0 8

0.4 15 0.7 1

0.0 10 0.5 7

0.3 0

0.0 8

0.4 8

0.4 3

0.1 5

0.2 0

0.0 4

0.2 1

0.0 0

0.0 3

0.1 2

0.1 1

0.0 5

0.2 3

0.1 6

0.3 2

0.1 4

0.2 8

0.4 6

0.3 5

0.2 1

0.0 0

0.0 4

0.2 3

0.1 0

0.0 7

0.3 11 0.5 1

0.0 3

0.1 11 0.5 1

0.0 4

0.2 1

0.0 1

0.0 2

0.1 0

0.0 6

0.3 2

0.1 0

0.0 6

0.3 8

0.4 8

0.4 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 1

0.0 4

0.2 4

0.2 1

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 5

0.2 1

0.0 4

0.2 2

0.1 1

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 23 1.1 18 0.8 16 0.7 9

0.4 5

0.2 7

0.3 21 1.0 16 0.7 21 1.0 14 0.7 20 0.9 15 0.7 7

0.3 4

0.2 11 0.5 22 1.0 0

0.0 10 0.5 39 1.8 76 3.6 80 3.7 11 0.5 13 0.6 229 10.7 MEAN WIND SPEED:

12.4 MISSING:

0

ARTIFICIAL ISLAND 01/05-03/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 150 FT DELTA T: (300-33FT)

LAPSE RATE:

GT 4.0 DEG C/1OOM CLASS G WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5

7. 6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW WSW NSN wW NW NNW 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 0

0.0 0

0.0 1

0.0 1

0.0 0

0.0 1

0.0 1

0.0 2

0.1 2

0.1 0

0.0 1

0.0 0

0'.0-0 0.0 3

0.1 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 2

0.1 3

0.1 0

0.0 I

0.0 0

0.0 1

0.-

0 0

G.0 1

0.00 0

0.0 i

0.0 3

0.1 0

0.0 3

0.1 7

0.3 2

0.1 2

0.1 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 2

0.1 7

0.3 11 0.5 2

0.1 4

0.2 0

0.0 1

0.0 0

0.0 0

0.0 1

t0.0 3

0.1 0

0.0° 0

0.0 0

0.0 0

0-0 0

0.

0 2

0.1 1

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 6

0.3 4

0.2 0

0.0 0

0.0 0

0.0 0'

0:.0 0:

0.0 0

0.0 0

0-0 0

0 0

0 0

0 0

6 1

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.3 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 6

0.3 10 0.5 5

0.2 0

0.0 0

0.0 2

0.1 6

0.3 33 1.5 12 0.6 3

0.1 2

0.1 7

0.3 0

0.0 2

0.1 0

0.0 4

0.2 0

0.0 10 0.5 13 0.6 21 1.0 31 1.5 10-0.15 0.3 92 4.3 MEAN WIND SPEED:

12.9 MISSING:

0 r-rt= r7

r. "1 r V1 1-C Gr C

r-7 r-u-

r-r_

r

or-,:V7 r-"

r7 or-,

p" r

U-r

=73

-7 Up=r771U-Ion-IL" tOr t!3 r7.

ad7 ARTIFICIAL ISLAND 01/05-03/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 150 FT DELTA T: (300-33FT)

ALL STABILITY CLASSES WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5

7. 6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0.0 2

0.1 23 1.1 84 3.9 78 3.7 12 0.6 1

0.0 0

0.0 3

0.1 15 0.7 93 4.4 59 2.8 5

0.2 0

0.0 0

0.0 3

0.1 29 1.4 87 4.1 39 1.8 6

0.3 0

0.0 0

0.0 4

0.2 38 1.8 37 1.7 6

0.3 6

0.3 0

0.0 0

0.0 2

0.1 30 1.4 9

0.4 1

0.0 0

0.0 0

0.0 0

0.0 4

0.2 24 1.1 31 1.5 16 0.7 3

0.1 0

0.0 0

0.0 5

0.2 20 0.9 29 1.4 38 1.8 18 0.8 10 0.5 0

0.0 3

0.1 27 1.3 33 1.5 39 1.8 16 0.7 8

0.4 0

0.0 10 0.5 25 1.2 15 0.7 11 0.5 11 0.5 5

0.2 0

0.0 6

0.3 9

0.4 9

0.4 10 0.5 5

0.2 3

0.1 0

0.0 7

0.3 23 1.1 27 1.3 13 0.6 1

0.0 4

0.2 0

0.0 4

0.2 15 0.7 32 1.5 52 2.4 11 0.5 0

0.0 0

0.0 3

0.1 14 0.7 45 2.1 30 1.4 17 0.8 0

0.0 0

0.0 4

0.2 23 1.1 58 2.7 53 2.5 36 1.7 13 0.6 0

0.0 7

0.3 27 1.3 47 2.2 127 6.0 67 3.1 38 1.8 0

0.0 3

0.1 32 1.5 76 3.6 70 3.3 26 1.2 14 0.7 0

0.0 70 3.3 374 17.5 712 33.4 642 30.1 240 11.2 96 4.5 200 9.4 175 8.2 164 7.7 91 4.3 42 2.0 78 3.7 120 5.6 126 5.9 77 3.6 42 2.0 75 3.5 114 5.3 109 5.1 187 8.8 313 14.7 221 10.4 2134 100.0 MISSING HOURS:

26 MEAN WIND SPEED:

12.6

ARTIFICIAL ISLAND 01/05-03/05 JOINT DISTRIBUTION-OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 150 FT DELTA T: (300-33FT)

DIRECTION VS SPEED ONLY WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0.0 0

0.0 0

0.0 0

0 0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 2

0.1 23 3

0.1 15 3

0.1 29 5

0.2 38 2

0.1 30 4

0.2 24 5

0.2 20 3

0.1 27 10 0.5 25 6

0.3 9

7 0.3 23 4

0.2 15 3

0.1 14 4

0.2 23 7

0.3 27 3

0.1 32 1.1 84 3.9 78 3.6 12 0.6 0.7 93 4.4 59 2.8 5

0.2 1.4 87 4.1 39 1.8 6

0.3 1.8 37 1.7 6

0.3 6

0.3 1.4 9

0.4 1

0.0 0

0.0 1.1 32 1.5 16 0.7 3

0.1 0.9 30 1.4 38 1.8 18 0.8 1%.-3 33 1.5

-39 1.8 16 0.7 1.2 15 0.7 11 0.5 11 0.5 0.4 9

0.4 10 0.5 5

0.2 1.1 27 1.3 13 0.6 1

0.0 0.7 32 1.5 52 2.4 11 0.5 0 7 45 2.1 30

-.4 17 0.8 1.-

58 2.7 53 2.5 36 1.7 1.3 47

2-.2 127 5-.9 67 3.1 1.5 76 31.6
70 3.-3 26 1.2-1 0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 10 0.5 8

0.4 5

0.2 3

0.1 4

0.2 0

0.0 0

0.0 13 0.6 38 1.8 14 0.7 200 175 164 92 42 79 121 126 77 42 75 114 109 187 313 221 9.4 8.2 7.7 4.3 2.0 3.7 5.7 5.9 3.6 2.0 3.5 5.3 5.1 8.8 14.6 10.3 0

0.0 71 3.3 374 17.5 714 33.-4 642 30:.0 240

11..2 96 4.5 2137 100.0 MISSING HOURS:

23 MEAN WIND SPEED:

12.6 Cn rn rr r--J r rGC r-10 C= rC: f C=

Ar) rz dr 1U7 1-7r U

C' t

ARTIFICIAL ISLAND 01/05-03/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 300 FT DELTA T: (300-33FT)

LAPSE RATE:

LE -1.9 DEG C/lOOM CLASS A WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5

7. 6-12.5 12.6-18.5
18. 6-24. 5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 1

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 4

0.2 2

0.1 1

0.0 3

0.1 0

0.0 0

0.0 13 0.6 0

0.0 1

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 0

0.0 8

0.4 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 6

0.3 0

0.0 0

0.0 2

0.1 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 0

0.0 0

0.0 0

0.0 4

0.2 4

0.2 4

0.2 27 1.3 1

0.0 0

0.0 0

0.0 0

0.0 6

0.3 20 0.9 10 0.5 7

0.3 43 2.0 MEAN WIND SPEED:

18.0 MISSING:

0

ARTIFICIAL ISLAND 01/05-03/05 JOINT DISTRIBUTION OF WINDLDIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 30E0-FT DELTA-T: (300-33FT)

LAPSE RATE: -1.8 TO -1.7 DEG C/lOOM CLASS B WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT N

NNE NE ENE

E ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 SUM PERCENT 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

,0.0 0

'O. 0 0

0.0 SUM PERCENT 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 2

0-.I1 0

0.0 0Q 0.0 0

0.0 0

0-.0 SUM PERCENT 2

0.1 3

0.1 2

0.1 1

0.0 0

0.0 0

0.0 0

'0.0 0

-0.0 0

-0.0 0

0.0 0

0.0 0

0.0 2

0.1 0

0.0 1

0,O.0 2

0-.1 SUM PERCENT 3

0.1 7

0.3 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0.

0 0.0 0

0.0 0

0.0 1

0.0 0

0.0 5

0.2i 2

0.1 6

0.3 7

0.3 SUM PERCENT 3

0 0,

0 0

0 0,

0 0

3 3-3 1

10.

,2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0'.

1 0.0 0'.5 0 1 SUM PERCENT 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 2

0.1 4

0.2 5

0.2 0

0.0 8

0.4 10 0.5 2

0.1 1

0.0 0

0.0 1

0.0 1

0.0 1

0.0 0

0.0 0

0.0 1

0.0 5

0.2 12 0.6 7

0.3 22 1.0 11 0.5 0

0.0 0

0.0 3

.0.1 13 0.6

32.

1.5 23 1.1 11 0.5 82 3.8 MEAN WIND SPEED:

17.3 MISSING:.:

0 r-= rC G

1=

1 r-T rz rC= C= rc r1 r7 I

-7 ff 7 F7l O C1 IC

= G U

ARTIFICIAL ISLAND 01/05-03/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 300 FT DELTA T: (300-33FT)

LAPSE RATE: -1.6 TO -1.5 DEG C/1OOM CLASS C WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5

3. 6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

3 2

0 1

0 1

0 0

0 1

2 0

0 0

6 0.0 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0.0 0.0 0.3 4

7 3

1 0

0 0

0 0

0 0

1 3

4 4

8 0.2 0.3 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.2 0.2 0.4 3

4 2

0 0

0 0

0 0

0 0

4 1

1 7

12 0.1 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.2 0.0 0.0 0.3 0.6 2

1 0

0 0

0 0

2 0

0 0

1 0

2 4

2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0.0 0.0 0.0 0.0 0.1 0.2 0.1 0

0 0

0 0

0 0

0 0

0 0

0 2

2 4

1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.0 9

15 7

1 1

0 1

2 0

0

,1 8

6 9

19 29 0.4 0.7 0.3 0.0 0.0 0.0 0.0 0.1 0.0 0.0 0.0 0.4 0.3 0.4 0.9 1.3 0

0.0 0

0.0 16 0.7 35 1.6 34 1.6 14 0.6 9

0.4 108 5.0 MEAN WIND SPEED:

13.9 MISSING:

0

ARTIFICIAL ISLAND 01/05-03/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 300 FT DELTA T: (300-33FT)

LAPSE RATE: -1.4 TO -0.5 DEG C/1OOM CLASS D WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0.0 0

0.0 6

0.3 22 1.0 28 1.3 11 0.5 0

0.0 0

0.0 10 0.5 24 1.1 31 1.4 11 0.5 0

0.0 0

0.0 8

0.4 26 1.2 24 1.1 9

0.4 0

0.0 1

0.0 16 0.7 20 0.9 11 0.5 7

0.3 0

0.0 1

0.0 8

0.4 5

0.2 1

0.0 0

0.0 0

0.0 0

0.0 6

0.3 7

0.3 5

0.2 3

0.1 0

0.0 1

0.0 1

0.0 3

0.1 7

0.3 16 0.7 0

0.0 2

0.1 12 0.6 16 0.7 12 0-.,6

,6 0:3 0

0.0 3

0.1 5

0.2 3

0.1 6

0.3 2

0.1 0

0.0 1

0.0 7

0.3 3

0.1 5

0.2 0

0.0 0

0.0 1

0.0 4

0.2 9

0.4 0

0.0 0

0.0 0

0.0 2

0.,1 9

0.4 9

0.4 19 0-.9 6

0.3 0

0.0 2

0.1 2

0.1 16 0.7 20 0,.9 15 0-.7 0

0.0 1

0.0 9

0.4 14 0-.6 26 1.2 34 1.6 0

O.0 2

0.1 7

0.3 9

0.4 37 1.7 27 1u.3 0

0.0 2

0.1 8

0,.4 26 1.2 10 0.05 1O 0.5 0

0.0 19 0.9 118 5._5 212 9.8 242 11.2 157-

7. 3 3

0 1

0 0

0 5

0 0

0 2

1 2

28 49 24 0.1 0.0 0.0 0.0 0.0 0.0 0.2 0.0 0.0 0.0 0.1 0.0 0.1 1.3 2.3 1.1 70 3.2 76 3.5 68 3.2 55 2.6 15 0.7 21 1.0 33 1.5 48 2.2 19 0.9 16 0.7 16 0.7 46 2.1 57 2.6 112 5.2 131 6.1 80 3.7 115 5.3 863 40.1 MEAN WIND SPEED:

15.2 MISSING:

0 r=

r rC C

1 1

IC7 Q C-IJ-r r

r7 r --

r Fr7 r7c V-r U.

W Ia C:r-r 7 7 1 r3 7 I r c c

=

7 ARTIFICIAL ISLAND 01/05-03/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 300 FT DELTA T: (300-33FT)

LAPSE RATE: -0.4 TO 1.5 DEG C/1OOM CLASS E WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5

7. 6-12.5 12.6-18.5
18. 6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 7

0.3 15 0.7 39 1.8 11 0.5 2

0.17 6

0.3 18 0.8 12 0.6 0

0.0 2

0.1 4

0.2 22 1.0 22 1.0 1

0.0 1

0-0_0.

11 0.5 16 0.7 9

0.4 0

0.0 2

0.1 10 0.5 9

0.4 1

0.0 0

0.0 3

0.1 10 0.5 14 0.6 19 0.9 5

0.2 3

0.1 6

0.3 14 0.6 21 1.0 14 0.6 3

0.1 9

0.4 7

0.3 3

0.1 1

0.0 4

0.2 3

0.1 2

0.1 5

0.2 0

0.0 2

0.1 5

0.2 5

0.2 0

0.0 3

0.1 2

0.1 4

0.2 14 0.6 6

0.3 0

0.0 1

0.0 5

0.2 12 0.6 11 0.5 2

0.1 2

0.1 4

0.2 12 0.6 11 0.5 4

0.2 0

0.0 1

0.0 21 1.0 23 1.1 2

0.1 0

0.0 10 0.5 23 1.1 42 1.9 32 1.5 0

0.0 7

0.3 22 1.0 42 1.9 16 0.7 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 7

0.3 0

0.0 0

0.0 1

0.0 2

0.1 1

0.0 0

0.0 0

0.0 6

0.3 7

0.3 72 3.3 38 1.8 51 2.4 37 1.7 22 1.0 52 2.4 65 3.0 23 1.1 14 0.6 16 0.7 28 1.3 32 1.5 33 1.5 47 2.2 113 5.2 94 4.4 0

0.0 27 1.3 102 4.7 226 10.5 266 12.3 91 4.2 25 1.2 737 34.2 MEAN WIND SPEED:

13.1 MISSING:

0

ARTIFICIAL ISLAND 01/05-03/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 300 FT DELTA T: (300-33FT)

LAPSE RATE:

1.6 TO 4.0 DEG C/lOOM CLASS F WIND SPEED GROUPS (MPH) 0.o0-0.5 0.6-3.5 3.6-7-.5

7. 6-12.5 12.6-18.5
18. 6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE

,E ESE SE SSE SSW SW WSH

%NW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 1

1 0

1 0

1 0

1 1

0 1

2 0

0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0O.0 0'.1 0.0 3

1 1

4 1

2 1

1 1

2 1

1 I0 6

4 0

0.1 0.0 0.0 0.2 O.0 0.1 0.0 0.0 0.0 0.1 0.0 0.0 4 I 0.2 D:13 Oo-2 oc.-2 2

5 6

3 3

3 4

0 4

1 5

1 71 2

.4 0.1 0.2 0.3

-0.1 0.1 0.1 0.2 0.2 0.0 0.2 0.0 0.0 0.1 0.0 0.2 11 2

11 2

0 1

0

--8 5

4 12 5

5

1 2.

8 0.5 0.1 0.5 0.1 0.0 0.0 0.0 0.4 0.2 0.2 0.6 0.2 0.2 O -0 0.'1 0.4 4

9 5

0 0

1 4

1l 4

3 11

-5

.3 I0 O0 3

0.2 0.4 0.2 0.0 0.0 0.0 0.2 0.0:

0..

2 0.1 0.5 0.2 0.1 0.0 0:.0 00.1 0

0 0

0 0

0 5

1 4

4 1

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.2 0.0 0.2 0.2 0.0 0.0 0.0 0.0 0.0 0.0 21 18 23 10 4

8 14 12 19 14 30 13 9

10 9

15 1.0 0.8 1.1 0.5 0.2 0.4 0.6 0.6 0.9 0.6 1.4 0.6 0.4 0.5 0.4 0.7 0

0.0 10 0.5 29 1.3 45

2.1 77 3.6 53 2.5 15 0.7 229 10.6 MEAN WIND SPEED:

15.1 MISSING:::

0 rz z u -

U- ~

U r

1=

77

9.

r7 K

rr-

"?

e r"

Z r

r F-s D' ARTIFICIAL ISLAND 01/05-03/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 300 FT DELTA T: (300-33FT)

ALL STABILITY CLASSES WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5

3. 6-7.5 7.6-12.5
12. 6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0.0 1

0.0 19 0.9 47 2.2 85 3.9 31 1.4 3

0.1 0

0.0 4

0.2 21 1.0 60 2.8 60 2.8 21 1.0 0

0.0 0

0.0 3

0.1 15 0.7 61 2.8 62 2.9 20 0.9 1

0.0 0

0.0 3

0.1 31 1.4 42 1.9 22 1.0 7

0.3 0

0.0 0

0.0 3

0.1 20 0.9 17 0.8 2

0.1 0

0.0 0

0.0 0

0.0 4

0.2 19 0.9 24 1.1 25 1.2 9

0.4 1

0.0 0

0.0 4

0.2 10 0.5 24 1.1 29 1.3 34 1.6 17 0.8 0

0.0 6

0.3 22 1.0 23 1.1 27 1.3 13 0.6 5

0.2 0

0.0 8

0.4 11 0.5 9

0.4 28 1.3 15 0.7 7

0.3 0

0.0 3

0.1 18 0.8 9

0.4 11 0.5 11 0.5 5

0.2 0

0.0 3

0.1 10 0.5 28 1.3 19 0.9 11 0.5 5

0.2 0

0.0 4

0.2 21 1.0 24 1.1 43 2.0 20 0.9 2

0.1 0

0.0 4

0.2 11 0.5 37 1.7 44 2.0 26 1.2 6

0.3 0

0.0 2

0.1 18 0.8 44 2.0 53 2.5 39 1.8 35 1.6 0

0.0 5

0.2 21 1.0 38 1.8 107 5.0 81 3.8 70 3.2 0

0.0 2

0.1 22 1.0 62 2.9 80 3.7 33 1.5 32 1.5 0

0.0 59 2.7 289 13.4 549 25.5 697 32.4 371 17.2 189 8.8 186 8.6 166 7.7 162 7.5 105 4.9 42 1.9 82 3.8 118 5.5 96 4.5 78 3.6 57 2.6 76 3.5 114 5.3 128 5.9 191 8.9 322 14.9 231 10.7 2154 100.0 MISSING HOURS:

6 MEAN WIND SPEED:

14.5

ARTIFICIAL ISLAND 01/05-03/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 300 FT DELTA T: (300-33FT)

LAPSE RATE:

GT 4.0 DEG C/1OOM CLASS G WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5

7. 6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

0 0.0 NNE 0

0.0 NE 0

0.0 ENE :.:0 0.0 E

0 0.0 ESE 0

0.0 SE 0

0.0 SSE 0

0.0.

S 0

0.0 SSW 0

0.0 SW 0

0.0 WSW 0

0.0 W

0.

0.0 Wm 0,

0.0:

NW 0

0.0' NNw 0

0.0.

0 0.0 1

0.0 1

0.0 0

0.0 0

0.0 0

0.0 0

0.0

0.

0.0, 0

0.0 0

0.0 0

0.0 0

0,.0 0

0.0-0 0 0 1

0.0 0',

0.,

3 0.1 1

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 I

0:.0 2

0.1 4

0.2 0

0.0 2-0.1 5-0.-2 2

0.:1;-

0 0.0;

1.

0.0:

2 0.1 2

0.1 2

0.1 1

0.0 0

0.0 0

0.0 3

0.1

°0, 0.0 0

0.0 0

0.0 0

0.0 1

0.0 1

0.0 o-0:.0 0

0 OA 0..

  • O.O 1

0.0 3

0.1 3

0.1 0

0.0 0

0.0 0

0.0 0

0.0

.4.

0.2 12 0.6 2

0.1 0

0.0 O.

omo

.1-0.0 0

0_0 0

0.0

0.

0_0 0

0 5

0 0

0 0

1, 9

5 0

0Q' 0~

0.0 0.0 0.2 0.0 0.0 0.0 0.0 0.0 0.4 0.2 0.0 0,.1 0:.0 0.0 0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0

4.

0_2.

3 0.1 0

0.0 0

0.0 0

0.0 0

0.0 0

0.00 0

0.0 0

0.0 6

0.3 7

0.3 11 0.5 1

0.0 0

0.0 0

0.0 4

0.2 9

.0.4 26 1.2 11 0.5 0

0.0 6

0.3

7.

0.3 2

0.1 1

0.0 1

0.0 0

0.0.

3

0. 1 21, 190-12 0.6 26 1.2-23, 1.1_.

7 0.3 92 4.3 MEAN WIND SPEED:

14.5 MISSING:t-0 It rz r

IC=

rO 1= r1G r _ rz C rr

.- r -

r

r nrI=

Ir r

n r

rri

_,f--J Pi7 En71 C7 Fly W77 Fr77 TI lO-r-:

lRae17 r

ARTIFICIAL ISLAND 01/05-03/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 300 FT DELTA T: (300-33FT)

DIRECTION VS SPEED ONLY WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5

7. 6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 19 0.9 47 2.2 85 3.9 31 1.4 4

0.2 21 1.0 60 2.8 60 2.8 21 1.0 3

0.1 15 0.7 61 2.8 62 2.9 20 0.9 3

0.1 32 1.5 42 1.9 22 1.0 7

0.3 3

0.1 20 0.9 17 0.8 2

0.1 0

0.0 4

0.2 19 0.9 24 1.1 25 1.2 9

0.4 4

0.2 10 0.5 26 1.2 29 1.3 34 1.6 6

0.3 22 1.0 23 1.1 27 1.3 13 0.6 8

0.4 11 0.5 9

0.4 28 1.3 15 0.7 3

0.1 18 0.8 9

0.4 11 0.5 11 0.5 3

0.1 10 0.5 28 1.3 19 0.9 11 0.5 4

0.2 21 1.0 24 1.1 43 2.0 20 0.9 4

0.2 11 0.5 37 1.7 44 2.0 26 1.2 2

0.1 18 0.8 44 2.0 53 2.5 39 1.8 5

0.2 21 1.0 38 1.8 107 5.0 81 3.8 2

0.1 22 1.0 62 2.9 80 3.7 33 1.5 3

0.1 0

0.0 1

0.0 0

0.0 0

0.0 1

0.0 17 0.8 5

0.2 7

0.3 5

0.2 5

0.2 2

0.1 6

0.3 35 1.6 70 3.2 32 1.5 186 8.6 166 7.7 162 7.5 106 4.9 42 1.9 82 3.8 120 5.6 96 4.5 78 3.6 57 2.6 76 3.5 114 5.3 128 5.9 191 8.9 322 14.9 231 10.7 0

0.0 59 2.7 290 13.4 551 25.5 697 32.3 371 17.2 189 8.8 2157 100.0 MISSING HOURS:

3 MEAN WIND SPEED:

14.5

2005 SGS AND HCGS RADIOACTIVE EFFLUENTS RELEASE REPORT Lapse Rate Wind Distributions 300-33 Foot 4/2005 - 6/2005

_,4 p,-,

Vr r-W7 r--

I=

r773 Cr7l r77 r-

_r.

U77 C?

F 7

F-E ARTIFICIAL ISLAND 04/05-06/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 30 FT DELTA T: (300-33FT)

LAPSE RATE:

LE -1.9 DEG C/1OOM CLASS A WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5

7. 6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 1

2 1

0 1

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 7

11 11 5

1 0

5 10 2

0 1

3 5

2 5

5 0.3 0.5 0.5 0.2 0.0 0.0 0.2 0.5 0.1 0.0 0.0 0.1 0.2 0.1 0.2 0.2 SUM PERCENT 4

0.2 2

0.1 11 0.5 0

0.0 0

0.0 0

0.0 8

0.4 4

0.2 0

0.0 0

0.0 0

0.0 1

0.0 7

0.3 4

0.2 3

0.1 10 0.5 SUM PERCENT SUM PERCENT 0

0 0

0 0

0 0

5 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.2 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 11 13 22 5

1 0

14 21 3

0 2

4 12 6

8 15 0.5 0.6 1.0 0.2 0.0 0.0 0.6 1.0 0.1 0.0 0.1 0.2 0.6 0.3 0.4 0.7 0

0.0 0

0.0 5

0.2 73 3.4 54 2.5 5

0.2 0

0.0 137 6.3 MEAN WIND SPEED:

12.4 MISSING:

0

ARTIFICIAL ISLAND 04/05-06/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 30 FT DELTA T: (300-33FT)

LAPSE RATE: -1.8 TO -1.7 DEG C/1OOM CLASS B WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5

7. 6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 1

0 6

3 1

1 1

3 0

5 2

4 3

4 0

0 0.0 0.0 0.3 0.1 0.0 0.0 0.0 0.1 0.0 0.2 0.1 0.2 0.1 0.2 0.0 0.0 8

1 3

3 0

1 1

1 0

0 0

6 6

1 3

6 0.4 0.0 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.3 0.3 0.0 0.1 0.3 0

2 1

0 0

0 2

1 0

0 0

0 3

1 2

0 0.0 0.1 0.0 0.0 0.0 0.0 0.1 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0.1 0.0 0

0 0

0 0

0 1

3 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 9

3 10 6

1 2

5 8

0 5

2 10 12 6

5 6

0.4

0. 1 0.5 0.3 0.0 0.1 0.2 0.4 0.0 0.2 0.1 0.5 0.6 0.3 0.2 0.3 0

0.0 0

0.0 34 1.6 40 1.8 12 0.6 4

0.2 0

0.0 90 4.1 MEAN WIND SPEED:

MISSING:

9.5 0

Ui rz r7 r

I r-l ~nr-7lr-z ri r-rim7 rim r-7 r-7 run:-

fri r,

rU" tr" a en o gr, c: c s r.-

ARTIFICIAL ISLAND 04/05-06/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 30 FT DELTA T: (300-33FT)

LAPSE RATE: -1.6 TO -1.5 DEG C/1OOM CLASS C WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5

18. 6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WsW W

WNW NW NNW 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0.

0 0.0 0

0.0 0

0.0 6

0.3 2

0.1 2

0.1 4

0.2 4

0.2 1

0.0 8

0.4 12 0.6 1

0.0 1

0.0 3

0.1 0

0.0 2

0.1 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 2

0.1 2

0.1 4

0.2 2

0.1 1

0.0 6

0.3 3

0.1 3

0.1 0

0.0 5

0.2 1

0.0 0

0.0 9

0.4 1

0.0 1

0.0 2

0.1 3

0.1 1

0.0 2

0.1 6

0.3 7

0.3 2

0.1 5

0.2 2

0.1 3

0.1 4

0.2 0

0.0 4

0.2 7

0.3 2

0.1 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 2

0.1 2

0.1 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 10 0.5 9

0.4 21 1.0 4

0.2 2

0.1 0

0.0 10 0.5 11 0.5 6

0.3 6

0.3 11 0.5 6

0.3 15 0.7 9

0.4 7

0.3 13 0.6 0

0.0 0

0.0 55 2.5 54 2.5 27 1.2 4

0.2 0

0.0 140 6.4 MEAN WIND SPEED:

9.5 MISSING

0

ARTIFICIAL ISLAND 04/05-06/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 30 FT DELTA T: (300-33FT)

LAPSE RATE: -1.4 TO -0.5 DEG C/lOOM CLASS D WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5

18. 6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 11 0

0.0 17 3

0.1 12 2

0.1 21 1

0.0 20 0

0.0 8

3 0.1 10 2

0.1 14 3

0.1 27 1

0.0 44 1

0.0 17 1

0.0 17 1

0.0 20 1

0.0 12 2

0.1 14 4

0.2 16 0.5 15 0.7 0.8 20 0.9 0.6 29 1.3 1.0 29 1.3 0.9 9

0.4 0.4 18 0.8 0.5 44 2.0 0.6 33 1.5 1.2 46 2.1 2.0 20 0.9 0.8 26 1.2 0.8 25 1.1 0.9 34 1.6 0.6 23 1.1 0.6 16 0.7 0.7 10 0.5 5

0.2 13 0.6 7

0.3 2

0.1 0

0.0

0.

0.0 43 2.0 22 1.0 3

0.1 2

0.1 3

0.1 17 0.8 12 0.6 8

0.4 8

0.4 4

0.2 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 5

0.2 2

0.1 0

0.0 1

0.0 2

0.1 0

0.0 5

0.2 3

0.1 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 31 1.4 50 2.3 51 2.3 54 2.5 30 1.4 26 1.2 105 4.8 73 3.4 79 3.6 68 3.1 50 2.3 60 2.8 72 3.3 47 2.2 40 1.8 34 1.6 0

0.0 25 1.1 280 12.8 397 18.2 149 6.8 18 0.8 1

0.0 870 39.9 MEAN WIND SPEED:

9.4 MISSING

0 I- = rn: r1 r

0=

r r_

IG rFz_ rT r_ r=

r

_n"7 er3l tm r-_

VD7 O~r C-7 C?7 r-.

r7 r..

U7 r7-l7 r

,I" V

ARTIFICIAL ISLAND 04/05-06/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 30 FT DELTA T: (300-33FT)

LAPSE RATE: -0.4 TO 1.5 DEG C/1OOM CLASS E WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5

12. 6-18.5
18. 6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 S

3 3

9 5

1 1

4 2

2 1

3 6

6 5

4 0.2 0.1 0.1 0.4 0.2 0.0 0.0 0.2 0.1 0.1 0.0 0.1 0.3 0.3 0.2 0.2 24 26 31 18 7

16 18 17 18 19 26 33 26 30 32° 16 1.1 1.2 1.4 0.8 0.3 0.7 0.8 0.8 0.8 0.9 1.2 1.5 1.2 1.4 1.5 0.7 7

11 15 2

1 10 46 17 12 14 6

15 8

19 32 5

0.3 0.5 0.7 0.1 0.0 0.5 2.1 0.8 0.6 0.6 0.3 0.7 0.4 0.9 1.5 0.2 0

0 0

0 0

0 20 5

3 3

3 4

0 0

1 0

0.0 0.0 0.0 0.0 0.0 0.0 0.9 0.2 0.1 0.1 0.1 0.2 0.0 0.0 0.0 0.0 0

0 0

0 0

0 5

2 0

2 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.2 0.1 0.0 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 4

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.2 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 36 40 49 29 13 27 94 45 35 40 36 55 40 55 70 25 1.7 1.8 2.2 1.3 0.6 1.2 4.3 2.1 1.6 1.8 1.7 2.5 1.8 2.5 3.2 1.1 0

0.0 60 2.8 357 16.4 220 10.1 39 1.8 9

0.4 4

0.2 689 31.6 MEAN WIND SPEED:

7.5 MISSING

0

ARTIFICIAL ISLAND 04/05-06/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 30 FT DELTA T: (300-33FT)

LAPSE RATE:

1.6 TO 4.0 DEG C/lOOM CLASS F WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5

7. 6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 I2 0

0 2

0 2

4 0

1 0

3 1

3 1

2 0.0 0.1 0.0 0.0 0.1 0.0 0.1 0.2 0.0 0.0 0.0 0.1 0.0 0.1 0.0 0.1 6

8 4

3 0

2 14 7

7 3

5 15 6

8

'6 6

0.3 0.4 0.2 0.1 0.0 0.1 0.6 0.3 0.3 0.1 0.2 0.7 0.3 0.4 0.3 0.3 3

0 0

0 0

2 25 5

5 7

2 2

0 0

0 2

0.1 0.0 0.0 0.0 0.0 0.1 1.1 0.2 0.2 0.3 0.1 0.1 0.0 0.0 0.0 0.1 0

0 0

0 0

0 9

0 0

3 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.4 0.0 0.0 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

1 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 1

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 10 10 4

3 2

4 51 17 12 14 7

20 7

11 7

10 0.5 0.5 0.2 0.1 0.1 0.2 2.3 0.8 0.6 0.6 0.3 0.9 0.3 0.5 0.3 0.5 0

0.0 22 1.0 100 4.6 53 2.4 12 0.6 0.0 0.0 189 8.7 MEAN WIND SPEED:

MISSING:

7.2 0

r--,-,

r=

r7 r7n V"-l-r-7-7 r77-7 r7n rl-I f l _ _l_

[ 7 1

[ 7 7.

f -I 1 1 1 1]

[

ARTIFICIAL ISLAND 04/05-06/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC 61-54,-~

~s WIND: 30 FT DELTA T: (300-33FT)

LAPSE RATE:

GT 4.0 DEG C/1OOM CLASS G WIND SPEED GROUPS (MPH) 0.0-0.5

0. 6-3.5 3.6-7.5 7.6-12.5
12. 6-18.5
18. 6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUN PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

2 0

2 1

4 3

1 0

1 0

0 0

0 0.0 0.0 0.0 0.1 0.0 0.1 0.0 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 2

0 0

2 1

2 10 7

1 1

1 0

0 0

1 1

0.1 0.0 0.0 0.1 0.0 0.1 0.5 0.3 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

1 15 0

0 3

0 0

0 0

1 1

0.0 0.0 0.0 0.0 0.0 0.0 0.7 0.0 0.0 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 2

0 0

4 1

5 26 1 1 4

5 1

1 0

0 2

2 0.1 0.0 0.0 0.2 0.0 0.2 1.2 0.5 0.2 0.2 0.0 0.0 0.0 0.0 0.1 0.1 0

0.0 14 0.6 29 1.3 21 1.0 0

0.0 0

0.0 0

0.0 64 2.9 MEAN WIND-SPEED.

6.0 MISSING

O

ARTIFICIAL ISLAND 04/05-06/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 30 FT DELTA T: (300-33FT)

ALL STABILITY CLASSES WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5

3. 6-7. 5
7. 6-12.5 12.6-18.5
18. 6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0.0 6

0.3 50 2.3 42 0

0.0 5

0.2 55 2.5 47 0

0.0 6

0.3 61 2.8 70 0

0.0 13 0.6 48 2.2 42 0

0.0 8

0.4 31 1.4 11 0

0.0 3

0.1 29 1.3 32 0

0.0 7

0.3 56 2.6 138 0

0,0 14 0.6 52 2.4 67 0

0.0 8

0.4 57 2.6 68 0

0.0 5

0.2 77 3.5 45 0

0.0 2

0.1 61 2.8 36 0

0.0 8

0.4 71 3.3 54 0

0.0 8

0.4 57 2.6 59 0

0.0 10 0.5 56 2.6 50 0

0.0 8

0.4 56 2.6 61 0

0.0 10 0.5 43 2.0 36 0

0.0 121 5.6 860 39.5 858 1.9 2.2 3.2 1.9 0.5 1.5 6.3 3.1 3.1 2.1 1.7 2.5 2.7 2.3 2.8 1.7 11 0.5 0

0.0 18 0.8 0

0.0 20 0.9 0

0.0 2

0.1 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 86 3.9 13 0.6 38 1.7 15 0.7 6

0.3 0

0.0 8

0.4 3

0.1 7

0.3 2

0.1 23 1.1 0

0.0 29 1.3 5

0.2 15 0.7 3

0.1 14 0.6 0

0.0 16 0.7 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 5

0.2 0

0.0 0

0.0 0

0.0 1

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 109 5.0 125 5.7 157 7.2 105 4.8 50 2.3 64 2.9 305 14.0 186 8.5 139 6.4 138 6.3 109 5.0 156 7.2 158 7.3 134 6.1 139 6.4 105 4.8 39.4 293 13.4 41 1.9 6

0.3 2179 100.0 MISSING HOURS:

5 MEAN WIND SPEED:

8.7 rz-Urz

~l r -

-n r l r

r-r_

fiz rl-,

rzz r7zz rz U -7 r

7 rr r-o C'

t- "r=

v'7 vr ARTIFICIAL ISLAND 04/05-06/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 30 FT DELTA T: (300-33FT)

DIRECTION VS SPEED ONLY WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 6

0.3 5

0.2 6

0.3 13 0.6 8

0.4 3

0.1 7

0.3 14 0.6 8

0.4 5

0.2 2

0.1 8

0.4 8

0.4 10 0.5 8

0.4 10 0.5 50 2.3 42 1.9 11 0.5 55 2.5 47 2.2 18 0.8 61 2.8 70 3.2 20 0.9 48 2.2 42 1.9 2

0.1 31 1.4 11 0.5 0

0.0 29 1.3 32 1.5 0

0.0 56 2.6 141 6.5 86 3.9 53 2.4 67 3.1 38 1.7 57 2.6 68 3.1 6

0.3 77 3.5 45 2.1 8

0.4 61 2.8 36 1.6 7

0.3 71 3.3 54 2.5 23 1.1 57 2.6 59 2.7 29 1.3 56 2.6 50 2.3 15 0.7 56 2.6 61 2.8 14 0.6 43 2.0 36 1.6 16 0.7 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 13 0.6 15 0.7 0

0.0 3

0.1 2

0.1 0

0.0 5

0.2 3

0.1 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 5

0.2 0

0.0 0

0.0 0

0.0 1

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 109 5.0 125 5.7 157 7.2 105 4.8 50 2.3 64 2.9 308 14.1 187 8.6 139 6.4 138 6.3 109 5.0 156 7.1 158 7.2 134 6.1 139 6.4 105 4.8 0

0.0 121 5.5 861 39.4 861 39.4 293 13.4 41 1.9 6

0.3 2183 100.0 MISSING HOURS:

1 MEAN WIND SPEED-

_8.7

ARTIFICIAL ISLAND 04/05-06/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 150 FT DELTA T: (300-33FT)

LAPSE RATE:

LE -1.9 DEG C/1OOM CLASS A WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5

7. 6-12.5 12.6-18.5
18. 6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0..

0 0.0 0.0 0

0 0

0 0

0 0

0 1

0 1

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 6

4 2

1 1

0 3

4 2

0 1

3 3

0 2

2 0.3 0.2 0.1 0.0 0.0 0.0 0.1 0.2 0.1 0.0 0.0 0.1 0.1 0.0 0.1 0.1 5

12 11 4

0 0

3 11 0

0 0

2 3

2 5

7 0.2 0.6 0.5 0.2 0.0 0.0 0.1 0.5 0.0 0.0 0.0 0.1 0.1 0.1 0.2 0.3 0

0 6

0 0

0 2

11 0

0 0

0 5

4 1

6 0.0 0.0 0.3 0.0 0.0 0.0 0.1 0.5 0.0 0.0 0.0 0.0 0.2 0.2 0.0 0.3 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 11 16 19 5

1 0

8 26 3

0 2

5 11 6

8 15 0.5 0.8 0.9 0.2 0.0 0.0 0.4 1.2 0.1 0.0 0.1 0.2 0.5 0.3 0.4 0.7 0

0.0 0

0.0 2

0.1 34 1.6 65 3.1 35 1.7 0

0.0 136 6.5 MEAN WIND SPEED:

MISSING:

15.5 1

r r-_L.

1.

r O-r-,

r_ c_

rim ri_

f

J

_7 r

ARTIFICIAL ISLAND 04/05-06/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 150 FT DELTA T: (300-33FT)

LAPSE RATE: -1.8 TO -1.7 DEG C/lOOM CLASS B WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 1

0 2

2 1

0 0

1 1

1 0

2, 2

0 0

0 0.0 0.0 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1

0. 0 0.0 0.0 5

2 7

2 0

2 2

1 1

1 1

6 7

5 3

5 0.2 0.1 0.3 0.1 0.0 0.1 0.1 0.0 0.0 0.0 0.0 0.3 0.3 0.2 0.1 0.2 1

1 2

1 0

0 1

2 0

0 0

2 2

0 3

2 0.0 0.0 0.1 0.0 0.0 0.0 0.0 0.1 0.0 0.0 0.0 0.1 0.1 0.0 0.1 0.1 0

1 0

0 0

0 2

1 0

0 0

0 2

1 0

0 0.0 0.0 0.0 0.0 0.0 0.0

0. 1 0.0 0.0
0. 0
0. 0 0.0 0.1I 0.0 0.0
0. 0 0

0 0

0 0

0 0

3 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 7

4 11 5

1 2

5 8

2 2

1 10 13 6

6 7

0.3 0.2 0.5 0.2 0.0 0.1 0.2 0.4 0.1 0.1 0.0 0.5 0.6 0.3 0.3 0.3 0

0.0 0

0.0 13 0.6 50 2.4 17 0.8 7

0.3 3

0.1 90 4.3 MEAN WIND SPEED:

11.7 MISSING:

0

ARTIFICIAL ISLAND 04/05-06/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 150 FT DELTA T: (300-33FT)

LAPSE RATE: -1.6 TO -1.5 DEG C/1OOM CLASS C WIND SPEED GROUPS (MPH)

0. 0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5
18. 6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 3

2 4

1 0

2 0

2 3

4 2

2 2

2 1

1 0.1 0.1 0.2 0.0 0.0 0.1 0.0 0.1 0.1 0.2 0.1 0.1 0.1 0.1 0.0 0.0 4

4 9

3 1

0 1

2 1

1 3

4 6

5 3

9 0.2 0.2 0.4 0.1 0.0 0.0 0.0 0.1 0.0 0.0 0.1 0.2 0.3 0.2 0.1 0.4 2

1 8

1 0

0 2

5 1

1 2

0 4

1 2

2 0.1 0.0 0.4 0.0 0.0 0.0 0.1 0.2 0.0 0.0 0.1 0.0 0.2 0.0 0.1 0.1 1

11 0

0 0

1 5

0 0

0 1

3 2

0 1

0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.2 0.0 0.0 0.0 0.0 0.1.

0.1 0.0 0.0 0

0 0

0 0

0 1

1 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 10 8

22 5

1 2

5 15 5

6 7

7 15 10 6

13 0.5 0.4 1.0 0.2 0.0 0.1 0.2 0.7 0.2 0.3 0.3 0.3 0.7 0.5 0.3 0.6 0

0.0 0

0.0 31 1.5 56 2.7 32 1.5 16 0.8 2

0.1 137 6.5 MEAN WIND SPEED:

MISSING:

12.0 3

r-_- 7 r= r:7 rz :

r zr--

77 r- -

W7 r-V-77 r__

V7 r"3 Or"-

r7-r77-e"? V77 "l-lVPp 7

7 ARTIFICIAL ISLAND 04/05-06/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 150 FT DELTA T: (300-33FT)

LAPSE RATE: -1.4 TO -0.5 DEG C/lOOM CLASS D WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5

7. 6-12.5
12. 6-18. 5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 1

0 1

1 0

1 2

2 1

1 0

1 1

2 1

1 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0.0 6

6 9

11 10 4

3 9

13 18 10 12 12~

7 6

9 0.3 0.3 0.4 0.5 0.5 0.2 0.1 0.4 0.6 0.9 0.5 0.6 0.6 0.3 0.3 0.4 13 17 13 17 15 9

15 21 37 20 22 17 22 17 12 10 0.6 0.8 0.6 0.8 0.7 0.4 0.7 1.0 1.8 1.0 1.0 0.8 1.0 0.8 0.6 0.5 15 17 12 20 3

8 35 28 27 12 9

15 26 20 10 7

0.7 0.8 0.6 1.0 0.1 0.4 1.7 1.3 1.3 0.6 0.4 0.7 1.2 1.0 0.5 0.3 2

12 6

2 0

0 17 15 0

1 3

13 5

3 7

1 0.1 0.6 0.3 0.1 0.0 0.0 0.8 0.7 0.0 0.0 0.1 0.6 0.2 0.1 0.3 0.0 0

0 0

0 0

0 10 0

0 1

3 4

5 3

0 0.0 0.0 0.0 0.0 0.0 0.0 0.5 0.0 0.0 0.0 0.1 0.2 0.2 0.1 0.0 0.0 37 52 41 51 28 22 82 75 78 53 47 62 71 52 36 28 1.8 2.5 2.0 2.4 1.3 1.0 3.9 3.6 3.7 2.5 2.2 3.0 3.4 2.5 1.7 1.3 0

0.0 16 0.8 145 6.9 277 13.2 264 12.6 87 4.1 26 1.2 815 38.8 MEAN WIND SPEED:

12.6 MISSING:

55

ARTIFICIAL ISLAND 04/05-06/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 150 FT DELTA T: (300-33FT)

LAPSE RATE: -0.4 TO 1.5 DEG C/1OOM CLASS E WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5

7. 6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE!

S SSW SW WSW W

WNW NW NNW 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 2

0.1 12 0.6 0

0.0 9

0.4 20 1.0 0

0.0 6

0.3 22 1.0 1

0.0 9

0.4 14 0.7 3

0.1 12 0.6 3

0.1 0

0.0 4

0.2 11 0.5 2

0.1 9

0.4 14 0.7 2

0.1 6

0.3 13 0.6 2

0.1 8

0.4 12 0.6 0

0.0 11 0.5 16 0.8 2

0.1 11 0.5 18 0.9 0

0.0 18 0.9 24 1.1 2

0.1 12 0.6 23 1.1 5

0.2 16 0.8 24 1.1 0

0.0 5

0.2 19 0.9 2

0.1 6

0.3 15 0.7 14 0.7 14 0.7 10 0.5 2

0.1 1

0.0 7

0.3 27 1.3 19 0.9 5

0.2 10 0.5 8

0.4 14 0.7 7

0.3 15 0.7 34 1.6 7

0.3 0

0 0

0 0

1 10 4

3 2

3 3

0 0

1 0

0.0 0.0 0.0 0.0 0.0 0.0 0.5 0.2 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0

0 0

0 0

0 16 2

0 3

1 0

0 0

0 0

0.0 0.0 0.0 0.0 0.0 0.0 0.8 0.1 0.0 0.1 0.0 0.0 0.0 0.0 0.0 0.0 29 1.4 43 2.0 38 1.8 26 1.2 19 0.9 23 1.1 78 3.7 46 2.2 30 1.4 42 2.0 43 2.0 59 2.8 44 2.1 60 2.9 59 2.8 30 1.4 0

0.0 22 1.0 144 6.9 260 12.4 194 9.2 27 1.3 22 1.0 669 31.9 MEAN WIND SPEED:

11.4 MISSING:

20 C=

C. {:

Or" rnr rzc UI r7 t-

.1 rC_

r z _

I or-o~

m r7 31t.,

r-"-

o" FU47 en7 e""

M ran "7,W7U ARTIFICIAL ISLAND 04/05-06/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 150 FT DELTA T: (300-33FT)

LAPSE RATE:

1.6 TO 4.0 DEG C/1OOM CLASS F WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5

7. 6-12.5 12.6-18.5
18. 6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 5

0.2 3

0.1 0

0.0 3

0.1 4

0.2 1

0.0 5

0.2 0

0.0 3

0.1 2

0.1 0

0.0 1

0.0 0

0.0 0

0.0 1

0.0 2

0.1 1

0.0 2

0.1 5

0.2 13 0.6 4

0.2 4

0.2 11 0.5 2

0.1 7

0.3 5

0.2 3

0.1 4

0.2 9

0.4 1

0.0 4

0.2 4

0.2 3

0.1 13 0.6 6

0.3 5

0.2 6

0.3 0

0.0 6

0.3 8

0.4 0

0.0 2

0.1 2

0.1 4

0.2 0

0.0 2

0.1 2

0.1 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 11 0.5 2

0.1 0

0.0 5

0.2 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 1

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 9

0.4 7

0.3 6

0.3 5

0.2 1

0.0 4

0.2 32 1.5 22 1.0 14 0.7 21 1.0 9

0.4 22 1.0 11 0.5 14 0.7 8

0.4 4

0.2 0

0.0 0

0.0 35 1.7 72 3.4 62 3.0 18 0.9 z

0.1 189 9.0 MEAN WIND SPEED:

12.3 MISSING:

0

ARTIFICIAL ISLAND 04/05-06/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 150 FT DELTA T: (300-33FT)

LAPSE RATE:

GT 4.0 DEG C/1OOM CLASS G WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

1 0

0 0

0 0

0 0

0 1

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 1

0 1

1 1

4 4

2 0

1 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.2 0.2 0.1 0.0 0.0 0.0 0.0 1

0 0

0 0

1 4

5 1

2 6

1 0

0 1

0 0.0 0.0 0.0 0.0 0.0 0.0 0.2 0.2 0.0 0.1 0.3 0.0 0.0 0.0 0.0 0.0 1

0 0

0 0

0 4

7 3

3 1

0 0

0 1

2 0.0 0.0 0.0 0.0 0.0 0.0 0.2 0.3 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.1 0

0 0

0 0

0 1

0 0

2 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0-0.0 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 2

0 0

0 1

2 10 13 5

11 11 3

0 1

3 2

0.1 0.0 0.0 0.0 0.0 0.1 0.5 0.6 0.2 0.5 0.5 0.1 0.0 0.0 0.1 0.1 0.0 0.1 15 0.7 22 1.0 22 1.0 3

0.1 0

0.0 64 3.0 MEAN WIND SPEED:

10.9 MISSING:

0 Cz C

=

r= r= r_- t, r=:

rc __

rT1 t::

7 fI C

I Ir -3 C

0 G

O I tI o C:

I--,

ARTIFICIAL ISLAND 04/05-06/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 150 FT DELTA T: (300-33FT)

ALL STABILITY CLASSES WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 2

0 1

2 3

2 4

4 3

1 2

1 3

7 2

3 0.1 13 0.6 0.0 17 0.8 0.0 22 1.0 0.1 26 1.2 0.1 25 1.2 0.1 11 0.5 0.2 15 0.7 0.2 23 1.1 0.1 29 1.4 0.0 41 2.0 0.1 29 1.4 0.0 39 1.9 0.1 331 1.6 0.3 32-1.5 0.1 14 0.7 0.1 16 0.8 46 50 58 39 20 25 44 50 61 44 55 68 67 59 42 43 2.2 2.4 2.8 1.9 1.0 1.2 2.1 2.4 2.9 2.1 2.6 3.2 3.2 2.8 2.0 2.0 41 2.0 49 2.3 43 2.0 28 1.3 4

0.2 16 0.8 85 4.0 83 4.0 41 2.0 35 1.7 24 1.1 39 1.9 42 2.0 38 1.8 59 2.8 29 1.4 3

0.1 14 0.7 13 0.6 2

0.1 0

0.0 1

0.0 44 2.1 38 1.8 3

0.1 10 0.5 6

0.3 17 0.8 15 0.7 10 0.5 9

0.4 8

0.4 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 28 1,3 7

0.3 0

0.0 4

0.2 4

0.2 4

0.2 5

0.2 3

0.1 0

0.0 0

0.0 105 5.0 130 6.2 137 6.5 97 4.6 52 2.5 55 2.6 220 10.5 205 9.8 137 6.5 135 6.4 120 5.7 168 8.0 165 7.9 149 7.1 126 6.0 99 4.7 0

0.0 40 1.9 385 18.3 771 36.7 656 31.2 193 9.2 55 2.6 2100 100.0 MISSING HOURS:

84 MEAN WIND SPEED:

12.2

ARTIFICIAL ISLAND 04/05-06/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 150 FT DELTA T: (300-33FT)

DIRECTION VS SPEED ONLY WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5

7. 6-12. 5 12.6-18.5
18. 6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 2

0.1 0

0.0 1

0.0 2

0.1 3

0.1 2

0.1 4

0.2 4

0.2 3

0.1 1

0.0 2

0.1 1

0.0 3

0.1 7

0.3 2

0.1 3

0.1 13 0.6 46 2.2 41 1.9 3

0.1 17 0.8 50 2.4 49 2.3 14 0.7 22 1.0 58 2.8 43 2.0 13 0.6 26 1.2 39 1.9 28 1.3 2

0.1 25 1.2 20 1.0 4

0.2 0

0.0 11 0.5 25 1.2 16 0.8 1

0.0 16 0.8 45 2.1 86 4.1 44 2.1 23 1.1 50 2.4 83 3.9 38 1.8 29 1.4 61 2.9 41 1.9 3

0.1 41 1.9 44 2.1 35 1.7 10 0.5 29 1.4 55 2.6 24 1.1 6

0.3 39 1.9 68 3.2 39 1.9 17 0.8 33 1.6 67 3.2 42 2.0 15 0.7 32 1.5 59 2.8 38 1.8 10 0.5 14 0.7 42 2.0 59 2.8 9

0.4 16 0.8 43 2.0 29 1.4 8

0.4 SUM PERCENT 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 28 1.3 7

0.3 0

0.0 4

0.2 4

0.2 4

0.2 5

0.2 3

0.1 0

0.0 0

0.0 105 130 137 97 52 55 223 205 137 135 120 168 165 149 126 99 5.0 6.2 6.5 4.6 2.5 2.6 10.6 9.7 6.5 6.4 5.7 8.0 7.8 7.1 6.0 4.7 0

0.0 40 1.9 386 18.4 772 36.7 657 31.2 193 9.2 55 2.6 2103 100.0 MISSING HOURS:

81 MEAN WIND SPEED:

12.2 rc-V r--

-, U -n =

C 71 r -, r rr r--

r-r-

r=

r--

rim rim rim z--

=7 CQ V77 r7 O"

-77 rn C.-

77

-7 7

p71 7

-77 W ARTIFICIAL ISLAND 04/05-06/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 300 FT DELTA T: (300-33FT)

LAPSE RATE:

LE -1.9 DEG C/1OOM CLASS A WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5

7. 6-12.5 12.6-18.5
18. 6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 1

0.0 0

0.0 1

0.0 0

0.0 0

0.0 0

0.0 0

0.0 4

0.2 5

0.2 2

0.1 9

0.4 3

0.1 11 0.5 1

0.0 4

0.2 1

0.0 0

0.0 1

0.0 0

0.0 1

0.0 3

0.1 6

0.3 10 0.5 2

0.1 0

0.0 0

0.0 0

0.0 1

0.0 0

0.0 2

0.1 3

0.1 3

0.1 3

0.1 0

0.0 2

0.1 1

0.0 4

0.2 1

0.0 9

0.4 1

0.0 2

0.1 6

0.3 0

0.0 0

0.0 0

0.0 4

0.2 8

0.4 0

0.0 0

0.0 0

0.0 0

0.0 4

0.2 3

0.1 3

0.1 7

0.3 0

0.0 0

0.0 1

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 1

0.0 0

0.0 0

0.0 10 0.5 13 0.6 21 1.0 5

0.2 1

0.0 1

0.0 8

0.4 25 1.1 3

0.1 1

0.0 1

0.0 6

0.3 11 0.5 6

0.3 8

0.4 17 0.8 0

0.0 0

0.0 3

0.1 29 1.3 63 2.9 38 1.7 4

0.2 137 6.3 MEAN WIND SPEED:

16.1 MISSING:

0

ARTIFICIAL ISLAND 04/05-06/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 300 FT DELTA T: (300-33FT)

LAPSE RATE: -1.8 TO -1.7 DEG C/1OOM CLASS B WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5

18. 6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 1

0 1

1 0

0 0

2 2

0 0

1 1

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 5

1 9

2 1

2 2

0 1

0 2

5 6

5 1

5 0.2 0.0

0. 4 0.1 0.0 0.1
0. 1 0.0 0.0 0.0 0.1 0.2 0.3 0.2 0.0 0.2 1

1 2

1 0

0 1

2 0

0 0

4 4

1 3

3 0.0 0.0 0.1 0.0 0.0 0.0 0.0 0.1 0.0 0.0 0.0 0.2 0.2 0.0 0.1 0.1 0

1 0

0 0

0 2

1 0

0 0

0 2

1 1

0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0.0 0.0 0

0 0

0 0

0 0

3 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 7

3 12 4

1 2

5 8

3 0

2 10 13 7

5 a

0.3 0.1 0.6 0.2 0.0 0.1 0.2 0.4 0.1 0.0 0.1 0.5 0.6 0.3 0.2 0.4 0

0.0 0

0.0 9

0.4 47 2.2 23 1.1 8

0.4 3

0.1 90 4.1 MEAN WIND SPEED:

MISSING:

12.3 0

f-

.._. v G T C T 1r r -

C

=r3

-1 r-- r ---

r U riU=

Urim Uri t r fm r

Mr7 en7" r7 7

r-7

~

u.

r"7 o-or",1-r""

em'" Ir7 r.-

OM Or--.:

ARTIFICIAL ISLAND 04/05-06/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 300 FT DELTA T: (300-33FT)

LAPSE RATE: -1.6 TO -1.5 DEG C/100M CLASS C WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 SUM PERCENT 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 SUM PERCENT SUM PERCENT SUM PERCENT 3

0.1 2

0.1 3

0.1 1

0.0 0

0.0 2

0.1 1

0.0 1

0.0 2

0.1 3

0.1 4

0.2 3

0.1 2

0.1 1

0.0 1

0.0 1

0.0 2

0.1 5

0.2 8

0.4 3

0.1 1

0.0 0

0.0 1

0.0 2

0.1 1

0.0 2

0.1 3

0.1 4

0.2 5

0.2 5

0.2 2

0.1 9

0.4 2

0.1 1

0.0 9

0.4 1

0.0 0

0.0 0

0.0 1

0.0 5

0.2 1

0.0 1

0.0 1

0.0 1

0.0 4

0.2 2

0.1 4

0.2 2

0.1 SUM PERCENT 2

0.1 1

0.0 1

0.0 0

0.0 0

0.0 0

0.0 1

0.0 6

0.3 0

0.0 0

0.0 1

0.0 1

0.0 4

0.2 1

0.0 0

0.0 1

0.0 SUM PERCENT 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 1

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 0

0.0 0

0.0 9

0.4 9

0.4 21 1.0 5

0.2 1

0.0 2

0.1 5

0.2 15 0.7 4

0.2 6

0.3 9

0.4 9

0.4 15 0.7 10 0.5 7

0.3 13 0.6 0

0.0 0

0.0 30 1.4 53 2.4 35 1.6 19 0.9 3

0.1 140 6.4 MEAN WIND SPEED:

12.5 MISSING:

I0--

ARTIFICIAL ISLAND 04/05-06/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 300 FT DELTA T: (300-33FT)

LAPSE RATE: -1.4 TO -0.5 DEG C/1OOM CLASS D WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5

18. 6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 2

1 0

0 1

1 2

0 0

0 1

1 2

0 0.0 0.0 0.1 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0.0 0.0 0.0 0.0 0.1 0.0 6

6 8

11 11 3

4 13 9

10 7

11 10 8

7 8

0.3 0.3 0.4 0.5 0.5 0.1 0.2 0.6 0.4 0.5 0.3 0.5 0.5 0.4 0.3 0.4 11 10 8

21 14 7

17 20 30 33 15 15 21 13 10 8

0.5 0.5 0.4 1.0 0.6 0.3 0.8 0.9 1.4 1.5 0.7 0.7 1.0 0.6 0.5 0.4 8

16 19 22 9

7 42 31 30 12 23 19 30 23 8

7 0.4 0.7 0.9 1.0 0.4 0.3 1.9 1.4 1.4 0.6 1.1 0.9 1.4 1.1 0.4 0.3 11 17 9

1 0

3 23 14 0

3 4

14 6

6 9

8 0.5 0.8 0.4 0.0 0.0 0.1 1.1 0.6 0.0 0.1 0.2 0.6 0.3 0.3 0.4 0.4 0

0 2

0 0

0 13 0

0 1

3 8

7 5

1 0

0.0 0.0 0.1 0.0 0.0 0.0 0.6 0.0 0.0 0.0 0.1 0.4 0.3 0.2 0.0 0.0 36 49 48 56 34 20 100 79 71 59 52 67 75 56 37 31 1.7 2.2 2.2 2.6 1.6 0.9 4.6 3.6 3.3 2.7 2.4 3.1 3.4 2.6 1.7 1.4 0

0.0 11 0.5 132 6.1 253 11.6 306 14.0 128 5.9 40 1.8 870 39.9 MEAN WIND SPEED:

MISSING:

13. 6 0

U77-11 U-7 r7-777 rCm rr.

=

V z

ri r-r

r Fr7 r77 C

F77 Or.

C77-0"-. 3 f7-Dr~

Ed7 Up W-77 l77 V7 ARTIFICIAL ISLAND 04/05-06/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 300 FT DELTA T: (300-33FT)

LAPSE RATE: -0.4 TO 1.5 DEG C/1OOM CLASS E WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5

7. 6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0 0

1 0

0 0

1 2

2 2

0 2

2 1

1 0.0 4

0.2 11 0.5 18 0.8 2

0.1 0.0 2

0.1 8

0.4 22 1.0 1

0.0 0.0 4

0.2 8

0.4 20 0.9 6

0.3 0.0 9

0.4 11 0.5 5

0.2 0

0.0 0.0 11 0.5 9

0.4 2

0.1 0

0.0 0.0 1

0.0 9

0.4 7

0.3 2

0.1 0.0 4

0.2 15 0.7 16 0.7 14 0.6 0.0 8

0.4 10 0.5 27 1.2 9

0.4 0.1 6

0.3 12 0.6 10 0.5 2

0.1 0.1 5

0.2 17 0.8 14 0.6 3

0.1 0.1 10 0.5 14 0.6 21 1.0 4

0.2 0.0 10 0.5 14 0.6 16 0.7 9

0.4 0.1 11 0.5 20 0.9 21 1.0 3

0.1 0.1 9

0.4 16 0.7 25 1.1 5

0.2 0.0 4

0.2 15 0.7 31 1.4 17 0.8 0.0 4

0.2 10 0.5 10 0.5 4

0.2 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 16 0.7 4

0.2 1

0.0 4

0.2 3

0.1 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 35 1.6 33 1.5 38 1.7 26 1.2 22 1.0 19 0.9 65 3.0 59 2.7 33 1.5 45 2.1 54 2.5 49 2.2 57 2.6 57 2.6 68 3.1 29 1.3 0

0.0 14 0.6 102 4.7 199 9.1 265 12.2 81 3.7 28 1.3 689 31.6 MEAN WIND SPEED:

13.5 MISSING:

0

ARTIFICIAL ISLAND 04/05-06/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 300 FT DELTA T: (300-33FT)

LAPSE RATE:

1.6 TO 4.0 DEG C/1OOM CLASS F WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5

7. 6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0~

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 1

0 0

0 0

0 1

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

1 0

1 2

4 1

1 2

3 2

0 1

2 1

1 0.0 0.0 0.0 0.0 0.1 0.2 0.0 0.0 0.1 0.1 0.1 0.0 0.0 0.1 0.0 0.0 1

3 1

1 0

1 1

5 5

5 2

4 6

5 2

4 0.0 0.1 0.0 0.0 0.0 0.0 0.0 0.2 0.2 0.2 0.1 0.2 0.3 0.2 0.1 0.2 4

6 1

0 0

0 2

15 11 8

7 14 2

5 6

3 0.2 0.3 0.0 0.0 0.0 0.0 0.1 0.7 0.5 0.4 0.3 0.6 0.1 0.2 0.3 0.1 0

3 0

0 0

0 5

4 0

12 2

2 0

0 1

0.0 0.1 0.0 0.0 0.0 0.0 0.2 0.2 0.0 0.6 0.1 0.1 0.0 0.0 0.0 0.0 0

0 0

0 0

0 4

'1 0

1 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.2 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 6

13 2

2 2

5 14 26 18 29 13 20 9

12 9

9 0.3 0.6 0.1 0.1 0.1 0.2 0.6 1.2 0.8 1.3 0.6 0.9 0.4 0.6 0.4 0.4 0

0.0 2

0.1 22 1.0 46 2.1 84 3.9 29 1.3 0.3 189 8.7 MEAN WIND SPEED:

MISSING:

u-_

C=

G I

14.3 0

r--l r77 U-7 rim i : lr-. r77 rm-Ur

f TC:C:

h 30C

!C m C C [

ARTIFICIAL ISLAND 04/05-06/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 300 FT DELTA T: (300-33FT)

LAPSE RATE:

GT 4.0 DEG C/lOOM CLASS G WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

1 2

0 1

0 0

1 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 3

0 5

3 3

5 0

0 2

1 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0.2 0.1 0.1 0.2 0.0 0.0 0.1 0.0 3

0 0

0 0

0 0

4 6

3 7

5 0

0 0

0 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.2 0.3 0.1 0.3 0.2 0.0 0.0 0.0 0.0 1

1 0

0 0

0 0

0 1

5 1

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.2 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 4

1 0

0 0

0 3

5 14 11 12 10 0

1 2

1 0.2 0.0 0.0 0.0 0.0 0.0 0.1 0.2 0.6 0.5 0.6 0.5 0.0 0.0 0.1 0.0 0

0.0 0

0.0 5

0.2 22 1.0 28 1.3 9

0.4 0

0.0 64 2.9 MEAN WIND SPEED:

13.5 MISSING: -0 O

ARTIFICIAL ISLAND 04/05-06/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 300 FT DELTA T: (300-33FT)

ALL STABILITY CLASSES WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5

18. 6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 14 0

0.0 11 2

0.1 16 2

0.1 23 0

0.0 24 0

0.0 10 2

0.1 10 2

0.1 26 4

0.2 24 2

0.1 22 2

0.1 24 0

0.0 26 3

0.1 25 3

0.1 21 3

0.1 13 1

0.0 14 0.6 0.5 0.7 1.1 1.1 0.5 0.5 1.2 1.1 1.0 1.1 1.2 1.1 1.0 0.6 0.6 34 1.6 41 1.9 17 29 1.3 55 2.5 26 37 1.7 62 2.8 22 39 1.8 33 1.5 1

26 1.2 11 0.5 0

20 0.9 14 0.6 5

40 1.8 65 3.0 49 43 2.0 94 4.3 42 56 2.6 58 2.7 3

60 2.8 38 1.7 23 40 1.8 59 2.7 12 49 2.2 62 2.8 26 61 2.8 64 2.9 19 44 2.0 58 2.7 16 33 1.5 56 2.6 30 38 1.7 34 1.6 21 0.8 0

0.0 1.2 0

0.0 1.0 3

0.1 0.0 0

0.0 0.0 0

0.0 0.2 0

0.0 2.2 34 1.6 1.9 10 0.5 0.1 1

0.0 1.1 6

0.3 0.6 6

0.3 1.2 8

0.4 0.9 8

0.4 0.7 7

0.3 1.4 1

0.0 1.0 0

0.0 14.3 84 3.9 107 4.9 121 5.6 142 6.5 98 4.5 61 2.8 49 2.2 200 9.2 217 10.0 146 6.7 151 6.9 143 6.6 171 7.8 180 8.3 149 6.8 136 6.2 108 5.0 2179 100.0 0

0.0 27 1.2 303 13.9 649 29.8 804 36.9 312 MISSING HOURS:

5 MEAN WIND SPEED:

13.6 v.

rz r

= 7 r-z- ¢r ri_ r z r-_

rz:

ri:

c I

Ix 7~ f C3 C rU7 Em r:

I7 r-r ARTIFICIAL ISLAND 04/05-06/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 300 FT DELTA T: (300-33FT)

DIRECTION VS SPEED ONLY WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 0

0.0 2

0.1 2

0.1 0

0.0 0

0.0 2

0.1 2

0.1 4

0.2 2

0.1 2

0.1 0

0.0 3

0.1 3

0.1 3

0.1 1

0.0 14 0.6 34 1.6 41 1.9 11 0.5 29 1.3 55 2.5 16 0.7 37 1.7 62 2.8 23 1.1 39 1.8 33 1.5 24 1.1 26 1.2 11 0.5 10 0.5 20 0.9 14 0.6 10 0.5 40 1.8 67 3.1 27 1.2 43 2.0 94 4.3 25 1.1 56 2.6 58 2.7 22 1.0 60 2.7 38 1.7 24 1.1 40 1.8 59 2.7 26 1.2 49 2.2 62 2.8 25 1.1 61 2.8 64 2.9 21 1.0 44 2.0 58 2.7 13 0.6 33 1.5 56 2.6 14 0.6 38 1.7 34 1.6 305 14.0 649 29.7 806 36.9 17 0.8 0

0.0 26 1.2 0

0.0 22 1.0 3

0.1 1

0.0 0

0.0 0

0.0 0

0.0 5

0.2 0

0.0 49 2.2 34 1.6 42 1.9 10 0.5 3

0.1 1

0.0 23 1.1 6

0.3 12 0.5 6

0.3 26 1.2 8

0.4 19 0.9 8

0.4 16 0.7 7

0.3 30 1.4 1

0.0 21 1.0 0

0.0 312 14.3 84 3.8 107 4.9 121 5.5 142 6.5 98 4.5 61 2.8 49 2.2 202 9.3 218 10.0 147 6.7 151 6.9 143 6.6 171 7.8 180 8.2 149 6.8 136 6.2 108 4.9 2183 100.0 0

0.0 27 1.2 MISSING HOURS:

1 MEAN WIND SPEED:

13.6

2005 SGS AND HCGS RADIOACTIVE EFFLUENTS RELEASE REPORT Lap s e Rate Win DRI str iutions 300-33 Foot 7/2005 - 9/2005

Ir RC o

r7 C1 r3 I

- C '-

ARTIFICIAL ISLAND 07/05-09/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 30 FT DELTA T: (300-33FT)

LAPSE RATE:

LE -1.9 DEG C/1OOM CLASS A WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5

12. 6-18.5
18. 6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 SUM PERCENT 0

0.0 1

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 SUM PERCENT SUM PERCENT SUM PERCENT 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 1

0.0 0

0.0 0

0.0 0

0.0 1

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 SUM PERCENT 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 SUM PERCENT 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 2

0.1 0

0.0 0

0.0 0

0.0 1

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 0

0.0 3

0.1 0.0 0

0.0 0.0 5

0.2 MEAN WIND SPEED:

9.4 MISSING

0

ARTIFICIAL ISLAND 07/05-09/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 30 FT DELTA T: (300-33FT)

LAPSE RATE: -1.8 TO -1.7 DEG C/10OM CLASS B WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5

7. 6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0.0 0

0.0 0

0.0 0O 0.0 0

0.0 0

0.0 0

0.0 a

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 SUM PERCENT 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 a

0.0 0

0.0 0

0.0 0

0 0

0 0

0 2

2 2

1 1

2 0

0 0,

0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 Qa1 0.I 0.0 0.0 0.1 0.0 0,0 0.0 0.0 SUM PERCENT SUM PERCENT 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 6

0.3 7

0.3 0

0.0 0

0.0 1

0.0 5

0.2 0

0.0 U

0.0 d

o.o 0

.0o o SUM PERCENT 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 0

0.0 0

0.o 0

0.0 0

0.0 0

o.o 0

o'.0 0

0.o 0

0.0 0

o.0 SUM PERCENT 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.'0 0

0.0 O

0.o

0.

0_- O SUM PERCENT 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

d.o 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 9

0.4 9

0.4 2

0.1 1

0.0 2

0.1 7

0.3 0

0.0 0

0.0 0

0.0 0

0.0 0.0 0

0.0 10 0.5 19 0.9 1

0.0 0

0.IY 0

0.0 30 1.4 MEAN WIND SPEED:

8.9 MISSING

0 rt r:i 1

V-r r 1z Irn r71 rF? r1 r1 rim rI Vim rIC C=m rCm Ci I

or-",

r7 _

r=

n I

ARTIFICIAL ISLAND 07105-09/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 30 FT DELTA T: (300-33FT)

LAPSE RATE: -1.6 TO -1.5 DEG C/lOOM CLASS C WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5

7. 6-12.5

.12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

1 0

0 0

0 0

0 0

0 0

.1 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 5

1 0

0 1

1 2

15 7

4 7

6 4

0 0

3 0.2 0.0 0.0 0.0 0.0 0.0 0.1 0.7 0.3 0.2 0.3 0.3 0.2 0.0 0.0 0.1 0

0 0

0 0

0 11 8

2 1

1 8

1 1

4 3

0.0 0.0 0.0 0.0 0.0 0.0 0.5 0.4 0.1 0.0 0.0 0.4 0.0 0.0 0.2 0.1 0

0 0

0 0

0 2

1 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 o.0 5

2 0

0 1

1 15 24 9

5 8

15 5

1 4

6 0.2 0.1 0.0 0.0 0.0 0.0 0.7 1.1 0.4 0.2 0.4 0.7 0.2 0.0 0.2 0.3 0

0.0 2

0.1 56 2.5 40 1.8 3

0.1 0

0.0 0.0 101 4.6 MEAN WIND SPEED:

7.3 MISSING

0

ARTIFICIAL ISLAND 07/05-09/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND:.30 FT DELTA T: (300-33FT)

LAPSE RATE: -1.4 TO -0.5 DEG C/1OOM CLASS D WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5

18. 6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE S

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 5

0.2 32 1.5 18 0.8 7

0.3 14 0.6 10 0.5 2

0.1 27 1.2 5

0.2 2

0.1 33 1.5 4

0.2 5

0.2 34 1.5 0

0.0 1

0.0 19 0.9 5

0.2 5

0.2 19 0.9 52 2.4 5

0.2 31 1.4 65 2.9 2

0.1 62 2.8 47 2.1 2

0.1 34 1.5 18 G.8 2

0.1 45 2.0 21 i.o 4

0.2 1S 0.7 20 0.9 3

0.1 20 0.9 34 i'5 2

0.

15 0.7 9

0.4 1

0.0 29 15.3 17 0.8 6

0.3 53 2.4 23 1.0 1

0.0 4

0.2 0

0.0 0

0.0 0

0.0 0

0.0 40 1.8 15 0.7 15 0Y.7 14 0.6 6

0.3 1

0.0 0

0_0 6A.,

1 0.0 2

0.1 2

0.1 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 2

0.1 0

0.0 a

0.0 1

0.0 0

0.0 0

0.0 0

0.0 0

0.Q 0

0.0 0

070 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0. 0 0

0.0 0

0.0 56 2.5 35 1.6 34 1.5 39 1.8 39 1.8 25 1.1 118 5.4 116 5.3 126 5.7 69 3.1 74 3.4 40 1.8 57 2.6 27 1.2 49 2.2 84 3.8 0

0.0 54 2.4 482 21.9 348 15 8 101 4.6 3

0.1 0

0.0 988 44.8 MEAN WIND SPEED:

7.9 MISSING:'

0.

ft-r-

r7 r-i c

r rr, tr.

rn O rr i Cr_

rz r

uC

U-r",

ro 7,U-

'71r7 t"3 F7 V"O O"

CM C",

F:7r--

ARTIFICIAL ISLAND 07/05-09/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 30 FT DELTA T:

(300-33FT)

LAPSE RATE: -0.4 TO 1.5 DEG C/lOOM CLASS E WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5

18. 6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 10 9

10 17 18 7

1 0

0 2

2 6

13 18 9

6 0.5 0.4 0.5 0.8 0.8 0.3 0.0 0.0 0.0 0.1 0.1 0.3 0.6 0.8 0.4 0.3 38 32 53 20 31 52 12 9

12 30 51 37 17 36 43 13 1.7 1.5 2.4 0.9 1.4 2.4 0.5 0.4 0.5 1.4 2.3 1.7 0.8 1.6 2.0 0.6 13 5

6 4

5 5

29 14 10 28 20 7

7 12 9

9 0.6 0.2 0.3 0.2 0.2 0.2 1.3 0.6 0.5 1.3 0.9 0.3 0.3 0.5 0.4 0.4 2

0 0

0 0

1 12 20 4

3 1

0 1

1 2

1 0.1 0.0 0.0 0.0 0.0 0.0 0.5 0.9 0.2 0.1 0.0 0.0 0.0 0.0 0.1 0.0 0

0 0

0 0

0 0

2 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0

.0 0

0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 63 46 69 431 54 65 54 45 26 63 74 50 38 67 63 29 2.9 2.1 3.1 1.9 2.4 2.9 2.4 2.0 1.2 2.9 3.4 2.3 1.7 3.0 2.9 1.3 0

0.0 128 5.8 486 22.0 183 8.3 48 2.2 2

0.1 0

0.0 847 38.4 MEAN WIND SPEED:

6.5 MISSING

0

ARTIFICIAL ISLAND 07/05-09/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 30 FT DELTAT: (300-33FT)

LAPSE RATE:

1.6 TO 4.0 DEG C/1OOM CLASS F WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5

18. 6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 2

0.1 30 1.4 1

0.0 38 1.7 4

0.2 18 0.8 8

0.4 12 0.5 4

0.2 2

0.1 1

0.0 7

0.3 0

0.0 1

0.0 0.0 0

Q0.0 2

o.i i

0.0 0

0.0 1

0.0 1

0.0 3

0.1 2

0.1 8

0.4 4

0.2 7

0.3 5

0.2 12 0.5 1

0.0 13 0.6 2

0.1 16 07 3

0.1 1

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0

~o o.o 1

0.0 0

0.0 0

0.0 0 ~0.0 0 0.0 2

0.1I 6

0.3 0

0.0 0

0.0 0

0.0 O

0.0 0

0.0 0

0.0 1

0.0 1

0.0 0O 0.0 0

0.0 0

0.0 0

0.0 0

0:.0 0

a.0 o

0o.

0 0-.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 0

0.0.

0 0.0 0

0.0 0

0-.0 0

0.0 0

0.0 o

od.

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 o

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 35 1.6 40 1.8 22 1.0 20 0.9 6

0.3 8

0.4 2

0.1 2

0.1 3

0.1 2

0.1 4

0.2 10 0.5 11 0.5 17 0.8 16 0.7 24 1.1 0

0.0 37 1.7 169 7.7 13

0.6 2

04 1

0.0 0

0.0 222 10.1 MEAN WIND SPEED:

5.4 MISSING:-

0 "I

-, L i

r c z r-7 r

-- r i rn 7 r

t7 rn o

rr r

z 1u n orn I

W by7 C:- - F77 V7 7

,l 07 ton UwtoU r-j c-f-

or" i.

ARTIFICIAL ISLAND 07/05-09/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 30 FT DELTA T: (300-33FT)

LAPSE RATE:

GT 4.0 DEG C/1OOM CLASS G WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5

7. 6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 SUM PERCENT 0

0.0 0

0.0 0

0.0 1

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 0

0.0 0

0.0 0

0.0 3

0.1 5

0.2 2

0.1 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0O 0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 SUM PERCENT SUM PERCENT SUM PERCENT 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 SUM PERCENT 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 SUM PERCENT 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 3

0.1 5

0.2 2

0.1 1

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 0

0.0 0

0.0 0

0.0 0

0.0 2

0.1 10 0.5 0

.0.0 0

0.0 0

0.0 0

0.0 12 0.5 MEAN WIND SPEED:

4.9 MISSING

0

ARTIFICIAL ISLAND 07/05-09/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 30 FT DELTA Tt (300-33FT)

ALL STABILITY CLASSES WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5

18. 6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 17 0.8 108 4.9 34 1.5 19 0.9 90 4.1 16 0.7 16 0.7 100 4.5 11 0.5 28 1.3 65 2.9 8

0.4 27 1.2 68 3.1 5

0T.2 9

0.4 79 3.6 10 0.5 6

0.3 36 1.6 99 4.5 5

0.2 57 2.6 95 4.3 4

0.2 84 3..8 59 2-.7 4

0.2 70 3.2 48 2.2 5

0.2 107 4.9 43 2.0 13 0.6 68 3.1 41 1.9 21 i.0 48 2.2 42 1.9 25 1.1 63 2.9 22 1.0 li 0.5 85 3.9 32 1.5 14 0.6 85 3.9 41 1.9 3

0.1 4

0.2 0

0.0 0

0.0 0

0.0 1

0.0 56 2.5 38 1.7 19 0.9 17 0.8 7

0.3 1

0.0 1

0.0 2

0I 4

0-.2 3

o0.3.

0 0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 2

0.1 3

0.1 0

0.0 1

0.0 0

0.0 0

050 0

0.0:

0 0.0 0

0.0~

0 0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 o

o.o 0

0.0 0

0.0 0

0.0 o

o.o 0

0.o 0

0.0 0

0.0 0

0.0 162 7.3 129 5.9 127 5.8 101 4.6 100 4.5 99 4.5 199 9.0 198 9.0 166 7.5 140 6.3 162 7.3 123 5.6 112 5.1 112 5.1 132 6.0 143 6.5 0

0.0 224 10.2 1213 55-.0 606 27.5 MISSING HOURS:

3 MEAN WIND SPEED:

7.1 156 7.1 6

0.3 0

0.0 2205 100.0 Ut=

r-7 r

r7 r3 r7 r=i rn rc 1-J G7

{=

tTI It (II CI

W-en7 r7-7'r71 f77 r"

t"-

C".

ft'7 O~ im-C-7 r[,0l r_

ARTIFICIAL ISLAND 07/05-09/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 30 FT DELTA T: (300-33FT)

DIRECTION VS SPEED ONLY WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 17 0.8 108 4.9 34 1.5 3

0.1 19 0.9 90 4.1 16 0.7 4

0.2 16 0.7 100 4.5 11 0.5 0

0.0 28 1.3 65 2.9 8

0.4 0

0.0 27 1.2 68 3.1 5

0.2 0

0.0 9

0.4 79 3.6 10 0.5 1

0.0 6

0.3 36 1.6 99 4.5 56 2.5 5

0.2 57 2.6 95 4.3 38 1.7 4

0.2 84 3.8 59 2.7 19 0.9 4

0.2 70 3.2 48 2.2 17 0.8 5

0.2 109 4.9 43 1.9 7

0.3 13 0.6 68 3.1 41 1.9 1

0.0 21 1.0 48 2.2 42 1.9 1

0.0 25 1.1 63 2.9 22 1.0 2

0.1 11 0.5 85 3.9 32 1.4 4

0.2 14 0.6 85 3.9 41 1.9 3

0.1 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 2

0.1 3

0.1 0

0.0 1

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 162 7.3 129 5.8 127 5.8 101 4.6 100 4.5 99 4.5 199

9. 0 198
9. 0 166 7.5 140 6.3 164 7..4 123 5.6 112 5.1 112 5.1 132 6.0 143 6.5 0

0.0 MISSING HOURS~ff-l.- ; 1 224 10.1 1215 55.1 606 27.5 156 7.1 6

0.3 0

0.0 2207 100.0 MEAN WIND SPEED-

-7.0

ARTIFICIAL ISLAND 07/05-09/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 150 FT DELTA T: (300-33FT)

LAPSE RATE:

LE -1.9 DEG C/1OOM CLASS A WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

MNE NE ENE E

ESE SE SSE S

SSW SW WSW NW NNW 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0

0.

0.0 0

0.0 0

0.0 1

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0o 0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0

'0 0.0 0O 0.0 I0 0'0 1

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0

° I*o 1

'.0 0O 0.0

'0 0o.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 o

6ob 0o o.o o

o.:-

0 0.0 o

d.o 0

0.0 o

o.:o o

-o.o 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 1

0.0 0

0.0 0

0.0 0

0.0 1

0.o 0

o0.

o 0,0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

O.

0 0.0 0

0.0 0

1 0

0 0

0 1

2 0

0 0

1 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0.0 I0 0.

-i 0.0 3

0.I 0

0.0 0

0.0 95 0.2 MEAN WIND SPEED:

11.6 MISSING:.

0 i, -,

'i 

,

, i

gj7 U

rr7 r7 1r-l rF-7 r7 tc`

r cc C7 tx O7r I c-t

1-7 r71

- C 07 rl Or" 7-r7 C7 r=l Df' FK 7

17

'O ARTIFICIAL ISLAND 07/05-09/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 150 FT DELTA T: (300-33FT)

LAPSE RATE: -1.8 TO -1.7 DEG C/lOOM CLASS B WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5

18. 6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 3

1 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 3

7 0

0 0

6 1

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.3 0.0 0.0 0.0 0.3 0.0 0.0 0.0 0.0 0

0 0

0 0

0 1

6 0

0 1

1 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.3 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 4

13 3

1 1

7 1

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.2 0.6 0.1 0.0 0.0 0.3 0.0 0.0 0.0 0.0 0

0.0 0

0.0 4

0.2 17 0.8 9

0.4 0

0.0 0

0.0 30 1.4 MEAN WIND SPEED:

MISSING:-

10. 9 0-D

ARTIFICIAL ISLAND 07/05-09/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 150 FT DELTA T: (300-33FT)

LAPSE RATE: -1.6 TO -1.5 DEG C/1OOM CLASS C WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW H

WNW NW NNW 0

0.0 0

0.0 0

0.0 0

0.0

,0 0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 O

0.0 0

0.0 SUM PERCENT 0

0.0 1

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 0

0.0 0

0.0 0

0.0 0

0.0 SUM PERCENT 2

0.1 0

0.0 0

0.0 0

0.0 1

0.0 1

0.0 0

0.0 9

0.4 5

0.2 4

0.2 3

0.1 5

0.2 3

0.1 1

0.0 0

0.0 3

0.1 SUM PERCENT 3

0.1 0

0.0 0

0.0 0

0-.0 0

0 0

0 0.0 6

0.3 14 0.6 3

0.1 1

0.0 2

0.1 11 0.5 2

0.1 1

0-.0 4

D.2 2

0.1 SUM PERCENT 2

0.1 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 7

0.3 2

0.1 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 SUM PERCENT 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 1

0.0 0

0.0 0

0.0 0

0.0 0

0.0 o

0.0 0

0-. 0 0

0.0 0

0.0 SUM PERCENT 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 7

0.3 1

0.0 0

0.0 0

0.0 1

0.0 1

0.0 14 0.6 26 1.2 8

0.4 5

0.2 5

0.2 17 0.8 5

0.2 2

0.1 4

0.2 5

0.2 0

0.0 2

0.i 37 1.7 49 2.2 11 0.5 2

0.,1 0.0 101 4.6 MEAN WIND SPEED:

9.0 MISSING:-

0 f-=

ri m m

rG G

z ri m ri m

ri m i ri-J i c t

lV:

tor God Anl on7 rQ tsa" r7 3r t71 to-U71 71 0!'- §rt X-"K7 ARTIFICIAL ISLAND 07/05-09/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 150 FT DELTA T: (300-33FT)

LAPSE RATE: -1.4 TO -0.5 DEG C/100M CLASS D WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0.0 2

0.1 25 1.1 25 1.1 8

0.4 1

0.0 0

0.0 1

0.0 9

0.4 19 0.9 4

0.2 5

0.2 0

0.0 3

0.1 9

0.4 16 0.7 4

0.2 0

0.0 0

0.0 1

0.0 24 1.1 24 1.1 3

0.1 0

0.0 0

0.0 2

0.1 23 1.1 9

0.4 0

0.0 0

0.0 0

0.0 0

0.0 10 0.5 15 0.7 0

0.0 0

0.0 0

0.0 2

0.1 7

0.3 25 1.1 32 1.5 16 0.7 0

0.0 1

0.0 19 0.9 47 2.2 61 2.8 6

0.3 0

0.0 2

0.1 31 1.4 51 2.3 32 1.5 5

0.2 0

0.0 0

0.0 24 1.1 14 0.6 18 0.8 13 0.6 0

0.0 0

0.0 28 1.3 28 1.3 13 0.6 7

0.3 0

0.0 2

0.1 9

0.4 28 1.3 2

0.1 1

0.0 0

0.0 1

0.0 10 0.5 31 1.4 12 0.5 1

0.0 0

0.0 2

0.1 13 0.6 10 0.5 6

0.3 1

0.0 0

0.0 1

0.0 15 0.7 20 0.9 7

0.3 0

0.0 0

0.0 2

0.1 31 1.4 36 1.6 5

0.2 2

0.1 0

0.0 22 1.0 287 13.1 398 18.2 207 9.5 58 2.7 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 5

0.2 1

0.0 0

0.0 1

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 0

0.0 8

0.4 61 2.8 38 1.7 32 1.5 52 2.4 34 1.6 25 1.1 87 4.0 135 6.2 121 5.5 70 3.2 76 3.5 42 1.9 55 2.5 32 1.5 44 2.0 76 3.5 980 44.9 MEAN WIND SPEED:

10.3 MISSING:

8

ARTIFICIAL ISLAND 07/05-09/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 150 FT DELTA T: (300-33FT)

LAPSE RATE: -0.4 TO 1.5 DEG C/1OOM CLASS E WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5

7. 6-12.5
12. 6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0 2

3 4

4 2

4 1

0 1

I 2

3 3

2 0.0 7

0.3 23 1.1 17 0.8 0.0 10 0.5 22 1.0 7

0.3 0.1 15 0.7 40 1.8 6

0.3 0.1 21 1.0 18 0.8 5

0.2 0.2 30 1.4 5

0.2 0

0.0 0.2 13 0.6 44 2.0 1

0.0 0.1 8

0.4 28 1.3 24 1.1 0.2 8

0.4 12

-0.5 ~18 0.8 0.0 5

0.2 18 0.8 8

0.4 0.0 5

0.2 30 1.4 17 0.8 0.0 21 1.0 41 1.9 11 0.5 0.0 25 1.1 27 1.2 4

0.2 0X.1 26 1:2 11 0.5 4

0.2 0.1 19 Ot*9 35 1:6 5

0.Z 0.1 4

0.;88 258 10 0.35 0.1 4

0-.-2

-8 0.4 6

0.

4 0.2 2

0.1 1

0.0 0

0.0 0

0.0 0

0.0 4

0.2 10 0-5 7

0.3 1

0.0 1

0.0 0

0.0 1

0.-0 Q

0.0 2

0;1 2

0.1 0

0 0

0 0

0 0

1 0

0 0

0 0

0 0

1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 52 2.4 41 1.9 64 2.9 47 2.2 39 1.8 62 2.8 66 3.0 53 2.4 39 1.8 53 2.4 75 3.4 57 2.6 44 2.0 62 2.8 58 2.7 23 1.1 0

0.0 33 1.5 235 10.8 387 1-7.7 143 6.5 35 1.6.

2 0.1 835 38.2 MEAN WIND SPEED:

9.8 MISSING

12 f i c C c :- r c :- r =

r "

c :

n:

c c : r c n c c :

I -

r!.

97, V-11 rml t-rI

-7

-17r l

c-c or-c:.,-

ARTIFICIAL ISLAND 07/05-09/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 150 FT DELTA T: (300-33FT)

LAPSE RATE:

1.6 TO 4.0 DEG C/1OOM CLASS F WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5

12. 6-18. 5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW w

WNW NW NNW 0

0.0 0

0.0 0

0.0 O

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 4

0.2 13 0.6 8

0.4 0

0.0 4

0.2 26 1.2 6

0.3 1

0.0 4

0.2 15 0.7 5

0.2 1

0.0 2

0.1 11 0.5 0

0.0 1

0.0 7

0.3 0

0.0 0

0.0 2

0.1 4

0.2 6

0.3 2

0.1 0

0.0 2

0.1 2

0.1 2

0.1 0

0.0 1

0.0 0

0.0 0

0.0 0

0.0 1

0.0 1

0.0 0

0.0 0

0.0 1

0.0 1

0.0 1

0.0 2

0.1 0

0.0 1

0.0 0

0.0 0

0.0 2

0.1 4

0.2 0

0.0 0

0.0 14 0.6 7

0.3 0

0.0 0

0.0 8

0.4 8

0.4 0

0.0 0

0.0 1

0.0 5

0.2 4

0.2 0

0.0 4

0.2 11 0.5 12 0.5 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 0

0.0 2

0.1 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 26 1.2 36 1.6 25 1.1 14 0.6 8

0.4 14 0.6 7

0.3 1

0.0 4

0.2 3

0.1 3

0.1

  • 6 0.3 21 1.0 16 0.7 10 0.5 27 1.2 0

0.0 8

0.4 59 2.7 111 5.1 40 1.8 3

0.1 0

0.0 221 10.1 MEAN WIND SPEED:

9.6 MISSING

1

ARTIFICIAL ISLAND 07/05-09/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 150 FT DELTA T: (300-33FT)

LAPSE RATE:

GT 4.0 DEG C/1OOM CLASS G WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW NW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 SUM PERCENT 0

0.0 0

0.0 2

0.1 2

0.1 1

0.0 0

0.0 0

0.0 o0 0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 0

0o0 0

0.o:

0 0o.

SUM PERCENT 0

0.0 0

0.0 1

0.0 0

0.0 0

0.0 2

0.1 0

0.0 I0.

0Q.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.o 0

0.o0 0

0o.o o

-oo SUM PERCENT I0 0.0 0

0.0 3

0.1 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

o.o SUM PERCENT 0

0 0

0 0

0 0

0 0

0 0

Q 6

0 0

0 0.0 0.0 O.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0 0 0.0 0.0 0.

SUM PERCENT 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 6

0.3 2

0.1 1

0.0 2

0.1 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 6

0.3 3

-0.1 3

0.1 0

0-.0 0

0.0 12 0.5 MEAN WIND SPEED:

MISSING::

8.8 0

rrU r-l f.71 rr IJ 1"i r= 7 r-f t r-7m C J r12 i

.u ri m. rm t J

IF C:"

C"N r"7W-.

r",

r377 rGl I"

Bran RM U"-,,rlr"7V7r" r-O--

ARTIFICIAL ISLAND 07/05-09/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 150 FT DELTA T: (300-33FTA ALL STABILITY CLASSES WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 4

0.2 3

0.1 6

0.3 5

0.2 7

0.3 6

0.3 4

0.2 5

0.2 3

0.1 0

0.0 3

0.1 4

0.2 3

0.1 5

0.2 4

0.2 4

0.2 38 1.7 64 2.9 35 1.6 5

0.2 23 1.1 67 3.1 17 0.8 7

0.3 30 1.4 72 3.3 18 0.8 1

0.0 49 2.2 53 2.4 8

0.4 0

0.0 62 2.8 14 0.6 0

0.0 0

0.0 28 1.3 67 3.1 3

0.1 0

0.0 17 0.8 64 2.9 67 3.1 22 1.0 37 1.7 81 3.7 88 4.0 17 0.8 45 2.1 73 3.3 40 1.8 14 0.6 35 1.6 46 2.1 36 1.6 14 0.6 52 2.4 72 3.3 25 1.1 8

0.4 41 1.9 76 3.5 a

0.4 1

0.0 54 2.5 52 2.4 16 0.7 2

0.1 41 1.9 54 2.5 11 0.5 1

0.0 34 1.6 54 2.5 21 1.0 2

0.1 42 1.9 57 2.6 23 1.1 4

0.2 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 5

0.2 2

0.1 0

0.0 1

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 1

0.0 146 6.7 117 5.4 127 5.8 115 5.3 83 3.8 104 4.8 179 8.2 230 10.5 175 8.0 132 6.0 160 7.3 130 6.0 127 5.8 112 5.1 116 5.3 131 6.0 0

0.0 66 3.0 628 28.8 966 44.2 416 19.0 98 4.5 10 0.5 2184 100.0 MISSING HOURS:

24 MEAN WIND SPEED:

10.0

ARTIFICIAL ISLAND 07/05-09/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS I

WIND: 150 FT DELTA T: (300-33FT)

DIRECTION VS SPEED ONLY WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5

7. 6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

-ESE SE SSE S

SSW SW WSW 11 WNW NW NNW 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0'.0 0

0.0 0

0.0 0

0.0 4

0.2 38 1.7 3

0.1 23 1.1 6

0.3 30 1.4 5

0.2 49 2.2 7

0.3 62 2.8 6

0.3 28 1.3 4

0.2 17 0.8 5

0.2 37 1.7 3

0.1 45 2.1 0

0.0 36 1.6 3

0.1 53 2.4 4

0.2 41 1.9 3

0.1 54 2.5 5

0.2 41 1-.9 4

01.2 34 1.6 4

0.2 42 1 9 64 2.9 35 1.6 67 3.1 17 0.8 72 3.3 18 0.8 53 2.4 8

0.4 14 0.6 0

0.0 67 3.1 3

0.1 64 2.9 67 3.1

-81

-3.7 88 4.0 73 3.3 40 1.8 46 2.1 36 1.6 72 3.3 25 1.1 76 3.5 8

0.4 52 2.4 16 0-.7 54 2.5 11 0-.5 54 2.5 21 1.0 57 26 23

-.1 966 44.2 416 1-9-.-0 5

0.2 7

0.3 1

0.0 O

0.0 0

0.0 0

0.0 22 1.0 I7 0.8 14 0-.6 14 0.6 8

0.4 1

0.0 2

0.1 1

0_.0 2

0.1 4

0.2 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 5

0.2 2

0.1 0

0.0 1

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 1

0.0 146 6.7 117 5.4 127 5.8 115 5.3 83 3.8 104 4.8 179 8.2 230 10.5 175 8.0 133 6.1 161 7.4 130 5.9 127 5.8 112 5.1 116 5.3 131 6.0 0

0.0 66 3.0 630 28.8 98 4.5 10 0-.5 2186 100 0 MISSING HOURS:

22 MEAN WIND SPEED:

10.0 U

r r-r-=

A d

C.-

r7 1r3 TV tZn z'

r=

Ci-rz r-7r r

_r" t-7 r-.i "

0" I-I=

uoJu-u"3 rl7 WI UFP77 rO Vr',

V-77 r7

[7 ARTIFICIAL ISLAND 07/05-09/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 300 FT DELTA T: (300-33FT)

LAPSE RATE:

LE -1.9 DEG C/1DOM CLASS A WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5

12. 6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE s

SSW SW WSW W

WNW NW NNW 0

0 D

0 0

0 0

D 0

D 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 I

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

1 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 1

1 0

0 0

1 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 1

0 0

0 0

0 I

2 0

0 0

1 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0.0 1

0.0 0

0.0 1

0.0 3

0.1 0

0.0 0.0 5

0.2 MEAN WIND SPEED:

12.2 MISSING:

0

ARTIFICIAL ISLAND 07/05-09/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 300:FT DELTA T: (300-33FT)

LAPSE RATE: -1.8 TO -1.7 DEG C/lOOM CLASS B WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5

7. 6-12.5
12. 6-18. 5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE ESE SE SSE S

SSW SW WSW w

WNW NW NNW 0

0.0 0

0.0 0

0.0 0

0.0

=--0 0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 3

0.1 1

0.0 0

0.0 0

0.0 0

0.0 0

0'.0 0

06.0 0

0.0 0

o.0 0

0.0 0

0.0 0

0.0 0

0.0 0

o.0 4

0.2 6

0.3 0

0.0 0

0.0 0

0.0 3

0. 1 1

-0.0 0

0_0 0

'0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 3

0.1 4

0.2 0

0.0 0

0.0 1

0.0 4

0.2 0

0.0 0

0.0-0 0.0 0

0;.0 0

0 0

0 0

0 0

0, 0

0 0

0 0

0 0-0 0.0 0.0 0.0 0.0 0.0 0.0 0.0

0. 0 0.0 0.0 0.0 0.;0 O.0 0:.'0 0 0 0'.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0 0

0 0

0 7

10 3

1 1

7 1

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.3 0.5 0.1 0.0 0.0 0.3 0.0 0.0 0.0 0.0 0

0.0

.4 0.:2 14

.0.6 12

0. 5 0

0.0 0

0.0 0

0.0 30 1.4 MEAN WIND SPEED:

11.3 MISSING:

0 rr ri_

r-

r-r i

r r

-l r-r7m r -

rI=

c rm r -

m t' t

-i E?

to

" r-3 7l

_3 In

_1 to ARTIFICIAL ISLAND 07/05-09/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 300 FT DELTA T: (300-33FT)

LAPSE RATE: -1.6 TO -1.5 DEG C/1OOM CLASS C WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 0

0.0 0

0.0 0

0.0 0

0.0 2

0.1 2

0.1 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 0

0.0 1

0.0 0

0.0 0

0.0 6

0.3 6

0.3 14 0.6 4

0.2 4

0.2 4

0.2 1

0.0 3

0.1 1

0.0 3

0.1 13 0.6 1

0.0 4

0.2 1

0.0 0

0.0 1

0.0 2

0.1 2

0.1 3

0.1 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 8

0.4 2

0.1 0

0.0 0

0.0 1

0.0 2

0.1 0

0.0 1

0.0 2

0.1 2

0.1 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 1

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 4

0.2 0

0.0 1

0.0 0

0.0 1

0.0 1

0.0 15 0.7 23 1.0 8

0.4 5

0.2 5

0.2 19 0.9 5

0.2 2

0.1 5

0.2 7

0.3 0.0 2

0.1 29 1.3 50 2.3 18 0.8 2

0.1 0

0.0 101 4.6 MEAN WIND SPEED:

9.5 MISSING

0

ARTIFICIAL ISLAND 07/05-09/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 300 FT DELTA T: (300-33FT)

LAPSE RATE: -1.4 TO -0.5 DEG C/1OOM CLASS D WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5

7. 6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

0 0.0 NNE 0

0.0 NE 0

0.0 ENS I0 0.0 E

0 0.0 ESE 0

0.0 SE 0

0.0 SSE 0

0.0 S

0 0.0 SSW 0

0.0 SW 0

0.0 WSW 0

0.0 1w 0

0 0 WNW 0

0.0 NW 0

0.0 NNW 0

0.0 1

0.0 19 1

0.0 10 4

0.2 7

0 0.0 25 1

0.0 18 0

0.0 9

2 0.1 8

2 0.1 11 0

0.0 28 0

0.0 19 2

0.1 24 1

0.0 13 0

0.0 7

2 0.1 13 2

0.1 12 0

0.0 25 0.9 27 1.2 11 0.5 0

0.0 0.5 11 0.5 4

0.2 2

0.1 0.3 14 0.6 6

0.3 0

0.0 1.1 18 0.8 2

0.1 0

0.0 0.8 19 0.9 0

0.0 0

0.0 0.4 14 0.6 5

0.2 0

0.0 0.4 20 0.9 36 1.6 17 0.8 0.5 52 2.4 57 2.6 7

0.3 1.3 45 2.0 29 1.3 10 6.s 0.9 18 0.8 14 0.6 19 0.9 1.1 27 1.2 17 0.8 7

0.3 0-.6 20 0.9 9

0.4 3

0.1 0:3 3-8 1.7 16 o 7 2

0 1 0.-6 12 0.5 10 0.5 1

0_0 0.5 16 0.7 11 0.5 1

0.0 1:1 38 1.7 17 0.8 2

0.1 1

2 0

0 0

0 9

1 1

3 0

0 0

0 1

0 0.0 0.1 0.0 0.0 0.0 0.0 0.4 0.0 0.0 0.1 0.0 0.0 0.0 OO 0.0 0.0 59 2.7 30 1.4 31 1.4 45 2.0 38 1.7 28 1.3 92 4.2 130 5.9 113 5.1 73 3.3 77 3.5 46 2.1 63 2.9 38 1.7 43 2.0 82 3.7 0

0.0 18 0.8 248 11-2 38,9 17.6 244 11_1 71 3_2

-j.

I I f

1 18 0.8 988 44.8 MEAN WIND SPEED:

11.2 MISSING:-

0 C

r rC f 1 7 ri rC rn un Ci Or E

CZ C

1 C C r.

7 17j 3C r

C73 F3 tC ra ARTIFICIAL ISLAND 07/05-09/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 300 FT LAPSE RATE: -0.4 TO 1.5 DEG C/100M DELTA T: (300-33FT)

CLASS E WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

0 0.0 2

0.1 7

0.3 21 1.0 23 1.0 4

0.2 2

0.1 59 2.7 NNE 0

0.0 0

0.0 5

0.2 9

0.4 10 0.5 3

0.1 0

0.0 27 1.2 NE 0

0.0 1

0.0 6

0.3 19 0.9 18 0.8 1

0.0 0

0.0 45 2.0 ENE 0

0.0 0

0.0 16 0.7 23 1.0 6

0.3 0

0.0 0

0.0 45 2.0 E

0 0.0 3

0.1 19 0.9 14 0.6 9

0.4 0

0.0 0

0.0 45 2.0 ESE 0

0.0 0

0.0 8

0.4 23 1.0 23 1.0 0

0.0 0

0.0 54 2.4 SE 0

0.0 1

0.0 9

0.4 23 1.0 32 1.5 8

0.4 2

0.1 75 3.4 SSE 0

0.0 2

0.1 3

0.1 13 0.6 20 0.9 11 0.5 4

0.2 53 2.4 S

0 0.0 0

0.0 10 0.5 13 0.6 8

0.4 8

0.4 0

0.0 39 1.8 SSW 0

0.0 3

0.1 2

0.1 29 1.3 25 1.1 11 0.5 0

0.0 70 3.2 SW 0

0.0 1

0.0 5

0.2 30 1.4 29 1.3 6

0.3 0

0.0 71 3.2 WSW 0

0.0 0

0.0 9

0.4 30 1.4 18 0.8 1

0.0 0

0.0 58 2.6 W

0 0.0 1

0.0 18 0.8 19 0.9 7

0.3 1

0.0 0

0.0 46 2.1 WNW 0

0.0 0

0.0 19 0.9 35 1.6 21 1.0 4

0.2 0

0.0 79 3.6 NW 0

0.0 0

0.0 8

0.4 21 1.0 16 0.7 8

0.4 0

0.0 53 2.4 NNW 0

0.0 2

0.1 1

0.0 7

0.3 13 0.6 4

0.2 1

0.0 28 1.3 0

0.0 16 0.7 145 6.6 329 14.9 278 12.6 70 3.2 9

0.4 847 38.4 MEAN WIND SPEED-12,0 MISSING:

-X 0

ARTIFICIAL ISLAND 07/05-09/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 300 FT DELTA-T: (300-33ET)

LAPSE RATE:

1.6 TO 4.0 DEG C/1OOM CLASS F WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW WN HNW NW NNW 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0

-O 0.0 0

0.0 0

0.0 0

0.0 1

0 2

0 0

0 1

0 0

0 0

.0.~o 00 0.0 0.0 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.-0 0..:0 0.0 3

0.1 2

0.1 1

0.0 6

0.3 2

0.1 1

0.0 3

0.1 1

0.:0 1

0.0 0

0.0 1

0.0 2

0-.1

4 0.2

.1 0.0

.-1

,0. 0 2

0._1 14 0.6 12 0.5 9

0.4 22 1.0 4

0.2 10 0.5 4

0.2 1

0.0 3

0.1 0

0.0 4

0.2 6

0.3 6

0.3 5

0.2

,1 0-.0 0

O0.90 0

0.0 0

0.0 3

0.1 3

0.1 0

0.0 1

0.0 2

-01 1

0.0 11 0

.5

--2 0.1 12 0.-5 2

.0.1 5

.0.2 6

D-.3

.5 0.2

.14 0.6 2

0.1 2

0.1 3

0.1 0

0.0 0

0.0 0

0.0 0

0.0

.1 0.0 O

0.0 0

0.0 0

0. 0 1

0.0 o

o o-

.0 0.

-3 0.1 4

0.2 1

0 0

0 0

0 0

2 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0..1 0.0 0.0 0.0 0.0 0.0 0.0 0.0b o.o 33 1.5 35 1.6 20 0.9 11 0.5 5

0.2 11 0.5 15 0.7 5

0.2 1

0.0 6

0.3 2

0.1 6

0.3 17 0.8 15 0.7 15 0.7 25 1.1 4

0.2 31

-1}.4 83

.3.8

^85 3.19 0

0.0 16 0.7 3

0.1 222 10.1 MEAN WIND SPEED:

12.3 MISSING:

0 cm cim ro ;r r3 r-rn r-7

r.

i z

rim r..

r C C m I=

i-C?

Fn I:

3 0

rr Fn _:

gfr ARTIFICIAL ISLAND 07/05-09/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 300 FT DELTA T: (300-33FT)

LAPSE RATE:

GT 4.0 DEG C/1OOM CLASS G WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 SUM PERCENT 0

0.0 0

0.0 0

0.0 2

0.1 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 SUM PERCENT SUM PERCENT SUM PERCENT 1

0.0 0

0.0 1

0.0 0

0.0 0

0.0 1

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 2

0.1 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 SUM PERCENT 0

0.0 0

0.0 3

0.1 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 SUM PERCENT 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 0

0.0 4

0.2 2

0.1 0

0.0 2

0.1 2

0.1 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 0

0.0 0

0.0 0

0.0 2

0.1 3

0.1 4

0.2 0

0.0 3

0.1 0

0.0 12 0.5 MEAN WIND SPEED:

10.2 MISSING:

0

ARTIFICIAL ISLAND 07/05-09/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 300 FT DELTA T: (300-33FT)

ALL STABILITY CLASSES WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5

18. 6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE ESE SE SSE S

SSW SW WSW NW NNW NW NNW 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 5

1 8

2 4

0 4

4 0

3 3

2 1

2 2

2 0.2 0.0 0.4 0.1 0.2 0.0 0.2 0.2 0.0 0.1 0.1 0.1 0.0 0.1 0.1 0:1 32 1.5 64 2.9 46 2.1 6

0.3 17 0.8 29 1.3 36 1.6 7

0.3 15 0.7 37 1.7 34 1.5 7

0.3 47 2.1 45 2.0 9

0.4 0

0.0 40 1.8 36 1.6 9

0.4 0

0.0 20 0.9 42 1.9 34 1.5 0

0.0 20 0.9 61 2.8 85 3.9 26 1.2 21 1.0 87 3.9 84 3.8 20 0.9 46 2.1 62 2.8 37 1.7 18 0-.8 26 1.2 51 2.3 42 1.9 30 1.4 33 1.5 58 2.6 49 2.2 13 0.6 27 1.2 68 3.1 35 1.6 5

0.2 30 1.4 73 3;3 25 1.1 3

0.1 34 1:5 60 2.7 34 1.5 5

Q0.2 22 1;0 44 2:0 35 1z6 12 0.5 30 1-4 53 2.4 46 2.1 10 0.5 4

2 0

0 0

0 11 7

1 3

0 0

0 0

1 1

0.2 0.1 0.0 0.0 0.0 0.0 0.5 0.3 0.0 0.1 0.0 0.0 0.0 0.0 0.0 0.0 157 7.1 92 4.2 101 4.6 103 4.7 89 4.0 96 4.4 207 9.4 223 10.1 164 7.4 155 7.0 156 7.1 137 6.2 132 6.0 135 6.1 116 5.3 142 6.4 0

0.0 43 2.0 460 20`9.

870 39.5 640 29.0 162 7.3 30 1.4 2205 100.0 MISSING HOURS:

3 MEAN WIND SPEED:

11.. 5 R

tm C C

=

r1m f-ra 1 m r

t r-r r`N C:r rz C

7 t7 to7 er~1 r-ARTIFICIAL ISLAND 07/05-09/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 300 FT DELTA T: (300-33FT)

DIRECTION VS SPEED ONLY WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 5

0.2 32 1.4 64 2.9 46 2.1 6

0.3 1

0.0 17 0.8 29 1.3 36 1.6 7

0.3 8

0.4 15 0.7 37 1.7 34 1.5 7

0.3 2

0.1 47 2.1 45 2.0 9

0.4 0

0.0 4

0.2 40 1.8 36 1.6 9

0.4 0

0.0 0

0.0 20 0.9 42 1.9 34 1.5 0

0.0 4

0.2 20 0.9 61 2.8 85 3.9 26 1.2 4

0.2 21 1.0 87 3.9 84 3.8 20 0.9 0

0.0 46 2.1 62 2.8 37 1.7 18 0.8 3

0.1 27 1.2 51 2.3 42 1.9 30 1.4 3

0.1 34 1.5 58 2.6 49 2.2 13 0.6 2

0.1 27 1.2 68 3.1 35 1.6 5

0.2 1

0.0 30 1.4 73 3.3 25 1.1 3

0.1 2

0.1 34 1.5 60 2.7 34 1.5 5

0.2 2

0.1 22 1.0 44 2.0 35 1.6 12 0.5 2

0.1 30 1.4 53 2.4 46 2.1 10 0.5 4

0.2 2

0.1 0

0.0 0

0.0 0

0.0 0

0.0 11 0.5 7

0.3 1

0.0 3

0.1 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 1

0.0 157 7.1 92 4.2 101 4.6 103 4.7 89 4.0 96 4.3 207 9.4 223 10.1 164 7.4 156 7.1 157 7.1 137 6.2 132 6.0 135 6.1 116 5.3 142 6.4 0

0.0 43 1.9 462 20.9 870 39.4 640 29.0 162 7.3 30 1.4 2207 100.0 MISSING HOURS:

1 MEAN WIND SPEED:

11.5

2005 SGS AND HCGS RADIOACTIVE EFFLUENTS RELEASE REPORT Lapse Rate Wind Distributions 300-33 Foot 10/2005 :- 12/2005

Er" O77 F7?7 C 77 r--'

C 3 37 C C!l O

r7 C-7 IF7T lr-K ARTIFICIAL ISLAND 10/05-12/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 30 FT DELTA T: (300-33FT)

LAPSE RATE:

LE -1.9 DEG C/lOOM CLASS A WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S S SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0,

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0.

0 0

0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 1

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 1

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 0

0.0 0

0.0 1

0.0 MEAN WIND SPEED:

13.7 MISSING:

0

ARTIFICIAL ISLAND 10/05-12/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 30 FT DELTA T: (300-33FT)

LAPSE RATE: -1.8 TO -1.7 DEG C/1OOM CLASS B WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5

7. 6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

2 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

2 1

3 1

1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0.1 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 1

2 4

0 0.0 0.0 0.0 0.0 0.0.

0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.2 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

4 2

5 5

1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.2 0.1 0.2 0.2 0.0 0

0.0 0

0.0 2

0.1 8

0.4 7

0.3 0

0.0 0

0.0 17 0.8 MEAN WIND SPEED:

MISSING:

11.6 0

lr z : r - 7. c c

r

=

to-'-

1 F C' r r - -r i m ri m ri m ri m ri m 7 u V

IF7 r= c:-

r-r7 C07-rF" Q7 C7, C77 Orl7-j97r

-V37 C:7-KC7 C

ARTIFICIAL ISLAND 10/05-12/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 30 FT DELTA T: (300-33FT)

LAPSE RATE: -1.6 TO -1.5 DEG C/1OOM CLASS C WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5

12. 6-18.5
18. 6-24. 5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

1 0

0 0

0 2

0 0

0 0

1 I

1 1

2 0.0 O0.0 0.0 0.0 0.0 0.0 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 1

0 0

0 0

0 0

0 0

0 0

4 4

2 1

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.2 0.2 0.1 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 2

8 6

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.4 0.3 0.0 0

0 0

0 0

0 0

0 0

0 0

0 1

1 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 1

1 0

0 0

0 2

0 0

0 0

5 8

12 8

2 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0.0 0.0 0.0 0.2 0.4 0.5 0.4 0.1 0.0 0

0.0 9

0.4 12 0.5 16 0.7 2

0.1 0

0.0 39 1.8 MEAN WIND SPEED:

11.4 MISSING:

0

ARTIFICIAL ISLAND 10/05-12/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 30 FT DELTA T: (300-33FT)

LAPSE RATE: -1.4 TO -0.5 DEG C/lOOM CLASS D WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5

7. 6-12.5
12. 6-18.5
18. 6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0.0

  • 0 0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 23 1.0 19 0.9 2

0.1 46 2.1 26 1.2 1

0.0 20 0.9 7

0.3 4

0.2 7

0.3 1

0.0 3

0.1 4

0.2 0

0.0 2

0.1 6

0.3 1

0.0 1

0.0 4

0.2 8

0.4 1

0.0 14 0.6 10 0.5 5

0.2 20 0.9 18 0.8 0

0.0 9

0.4 11 0.5 3

0.1 18 0.8 12 0.5 4

0.2 18 0.8 20 0.9 1

0.0 12 0.5 39 1.8 3

0.1 24 1.1 33 1.5 0

0.0 11 0.5 57 2.6 0

0.0 9

0.4 19 0.9 3

0.1 8

0.4 6

0.3 0

0.0 0

0.0 0

0.0 2

0.1 3

0.1 4

0.2 4

0.2 7

0.3 1

0.0 39 1.8 40 1.8 49 2.2 9

0.4 0

0 0

0 0

0 3

1 0

0 0

0 10 0

7 0

0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0.0 0.0 0.0 0.0 0.5 0.0 0.3 0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 2

0.1 0

0.0 46 2.1 82 3.7 34 1.5 12 0.5 7

0.3 9

0.4 18 0.8 29 1.3 47 2.1 24 1.1 40 1.8 43 2.0 101 4.6 100 4.5 126 5.7 37 1.7 0

0.0 31 1.4 245 11.1 281 12.8 175 8.0 21 1.0 2

0.1 755 34.3 MEAN WIND SPEED:

9.8 MISSING

2 177.

ufLY?

r -T rUT r

4" UTj=

r 7

=

r-, r,

r=

rizi rzz--

r -i r z-ui r

ARTIFICIAL ISLAND 10/05-12/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 30 FT DELTA T: (300-33FT)

LAPSE RATE: -0.4 TO 1.5 DEG C/lOOM CLASS E WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5

7. 6-12.5
12. 6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 4

5 4

13 11 4

6 1

3 5

3 6

6 13 10 5

0.2 0.2 0.2 0.6 0.5 0.2 0.3 0.0 0.1 0.2 0.1 0.3 0.3 0.6 0.5 0.2 21 32 34 19 10 22 18 15 25 33 27 34 24 27 48 23 1.0 1.5 1.5 0.9 0.5 1.0 0.8 0.7 1.1 1.5 1.2 1.5 1.1 1.2 2.2 1.0 25 18 7

12 1

8 26 12 30 25 1 6 9

31 49 81 29 1.1 0.8 0.3 0.5 0.0 0.4 1.2 0.5 1.4 1.1 0.7 0.4 1.4 2.2 3.7 1.3 7

15 3

0 0

0 10 4

4 7

1 0

6 8

42 11 0.3 0.7 0.1 0.0 0.0 0.0 0.5 0.2 0.2 0.3 0.0 0.0 0.3 0.4 1.9 0.5 0

0 0

0 0

0 4

2 6

1 0

0 0

0 4

0 0.0 0.0 0.0 0.0 0.0 0.0 0.2 0.1 0.3 0.0 0.0 0.0 0.0 0.0 0.2 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 57 70 48 44 22 34 64 34 68 71 47 49 67 97 185 68 2.6 3.2 2.2 2.0 1.0 1.5 2.9 1.5 3.1 3.2 2.1 2.2 3.0 4.4 8.4 3.1 0

0.0 99 4.5 412 18.7 379 17.2 118 5.4 17 0.8 0

0.0 1025 46.6 MEAN WIND SPEED:

8.1 MISSING

1

ARTIFICIAL ISLAND 10/05-12/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 30 FT DELTA T: (300-33FT)

LAPSE RATE:

1.6 TO 4.0 DEG C/1OOM CLASS F WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5

7. 6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 7

4 11 1

5 4

3 4

4 2

2 0

4 4

1 3

0.3 0.2 0.5 0.0 0.2 0.2 0.1 0.2 0.2 0.1 0.1 0.0 0.2 0.2 0.0 0.1 1

8 18 5

5 16 17 11 3

6 12 5

2 2

4 3

0.0 0.4 0.8 0.2 0.2 0.7 0.8 0.5 0.1 0.3 0.5 0.2 0.1 0.1 0.2 0.1 1

0 0

0 3

1 25 7

4 1

0 1

0 0

1 0

0.0 0.0 0.0 0.0 0.1 0.0 1.1 0.3 0.2 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0

.1 0

8 11 6

1 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.4 0.5 0.3 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 11 0

0 0

0 0

0 0

0 0

0.0 0.0 0.0 0.0 0.0 0.0 0.5 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 1

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 9

12 29 6

14 21 65 33 17 10 14 6

6 6

6 6

0.4 0.5 1.3 0.3 0.6 1.0 3.0 1.5 0.8 0.5 0.6 0.3 0.3 0.3 0.3 0.3 0

0.0 59 2.7 118 5.4 44 2.0 27 1.2 11 0.5 1

0.0 260 11.8 MEAN WIND SPEED:

MISSING' 7.3 0

r~ T rr

_r -- U,7 r-"

l-1r=

C7 37 'l_ C

_C, C7 r z r z z ri=

r [ m

_' m r -

K CIC G?

NM C

7r 7

r 7n W

ARTIFICIAL ISLAND 10/05-12/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 30 FT DELTA T: (300-33FT)

LAPSE RATE:

GT 4.0 DEG C/1OOM CLASS G WIND SPEED GROUPS (MPH) 0.0-0.5 DIRECTION SUM PERCENT 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 0

0.0 0

0.0 1

0.0 1

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 2

0.1 2

0.1 2

0.1 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 0

0.0 0

0.0 9

0.4 0

0.0 0

0.0 4

0.2 0

0.0 0

0.0 2

0.1 0

0.0 0

0.0 12 0.5 0

0.0 0

0.0 11 0.5 14 0.6 17 0.8 5

0.2 4

0.2 4

0.2 0

0.0 0

0.0 0

0.0 1

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 0

0.0 0

0.0 3

0.1 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0.

0 0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 4

0.2 1

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

,0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 10 0.5 4

0.2 2

0.1 13 0.6 47 2.1 14 0.6 0

0.0 1

0.0 0

0.0 1

0.0 5

0.2 2

0.1 2

0.1 0

0.0 0

0.0 0.4 49 2.2 18 0.8 21 1.0 5

0.2 0

0.0 102 4.6 MEAN WIND SPEED:

8.6 MISSING

0

ARTIFICIAL ISLAND 10/05-12/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 30 FT DELTA T: (300-33FT)

ALL STABILITY CLASSES WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

0 0.0 12 0.5 45 2.0 46 2.1 10 0.5 0

0.0 0

0.0 113 5.1 NNE 0

0.0 11 0.5 88 4.0 44 2.0 23 1.0 0

0.0 0

0.0 166 7.5 NE 0

0.0 17 0.8 81 3.7 14 0.6 9

0.4 0

0.0 0

0.0 121 5.5 ENE 0

0.0 18 0.8 35 1.6 13 0.6 0

0.0 0

0.0 0

0.0 66 3.0 E

0 0.0 19 0.9 21 1.0 4

0.2 1

0.0 0

0.0 0

0.0 45 2.0 ESE 0

0.0 11 0.5 56 2.5 10 0.5 0

0.0 0

0.0 0

0.0 77 3.5 SE 0

0.0 11 0.5 52 2.4 73 3.3 37 1.7 22 1.0 1

0.0 196 8.9 SSE 0

0.0 6

0.3 45 2.0 33 1.5 22 1.0 4

0.2 0

0.0 110 5.0 S

0 0.0 12 0.5 48 2.2 52 2.4 14 0.6 6

0.3 0

0.0 132 6.0 SSW 0

0.0 7

0.3 49 2.2 37 1.7 12 0.5 1

0.0 0

0.0 106 4.8 SW 0

0.0 8

0.4 57 2.6 28 1.3 8

0.4 0

0.0 0

0.0 101 4.6 WSW 0

0.0 10 0.5 61 2.8 36 1.6 1

0.0 0

0.0 0

0.0 108 4.9 W

0 0.0 13 0.6 42 1.9 75 3.4 48 2.2 11 0.5 0

0.0 189 8.6 WNW 0

0.0 22 1.0 54 2.5 87 4.0 58 2.6 1

0.0 0

0.0 222 10.1 NW 0

0.0 13 0.6 64 2.9 141 6.4 102 4.6 11 0.5 2

0.1 333 15.1 NNW 0

0.0 8

0.4 37 1.7 49 2.2 20 0.9 0

0.0 0

0.0 114 5.2 0

0.0 198 9.0 835 38.0 742 33.7 365 16.6 56 2.5 3

0.1 2199 100.0 MISSING HOURS:

9 MEAN WIND SPEED:

8.7 r-_

r-7

-7 rl",

=

=

-7

=

7 V07 r77 r-1 F7 rz rim Fii-

r r7 r:

C3 7K 7

em 3

C M ARTIFICIAL ISLAND 10/05-12/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 30 FT DELTA T: (300-33FT)

DIRECTION VS SPEED ONLY WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

0 0.0 12 0.5 46 2.1 46 2.1 10 0.5 0

0.0 NNE 0

0.0 11 0.5 88 4.0 44 2.0 23 1.0 0

0.0 NE 0

0.0 17 0.8 81 3.7 14 0.6 9

0.4 0

0.0 ENE 0

0.0 18 0.8 35 1.6 13 0.6 0

0.0 0

0.0 E

0 0.0 19 0.9 21 1.0 4

0.2 1

0.0 0

0.0 ESE 0

0.0 11 0.5 56 2.5 10 0.5 0

0.0 0

0.0 SE 0

0.0 11 0.5 52 2.4 73 3.3 37 1.7 22 1.0 SSE 0

0.0 6

0.3 45 2.0 33 1.5 22 1.0 4

0.2 S

0 0.0 12 0.5 48 2.2 52 2.4 14 0.6 6

0.3 SSW 0

0.0 7

0.3 49 2.2 37 1.7 12 0.5 1

0.0 SW 0

0.0 8

0.4 57 2.6 28 1.3 8

0.4 0

0.0 WSW 0

0.0 10 0.5 61 2.8 36 1.6 1

0.0 0

0.0 W

0 0.0 13 0.6 42 1.9 75 3.4 48 2.2 11 0.5 WNW 0

0.0 22 1.0 54 2.5-87 4.0 58 2.6 1

0.0 NW 0

0.0 13 0.6 64 2.9 142 6.4 102 4.6 11 0.5 NNW 0

0.0 8

0.4 38 1.7 49 2.2 20 0.9 0

0.0 0

0.0 198 9.0 837 38.0 743 33.7 365 16.6 56 2.5 MISSING HOURS:

6 MEAN WIND SPEED:

8.7 SUM PERCENT 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0.

O 0.0 2

0.1 0

0.0 114 5.2 166 7.5 121 5.5 66 3.0 45 2.0 77 3.5 196 8.9 110 5.0 132 6.0 106 4.8 101 4.6 108 4.9 189 8.6 222 10.1 334 15.2 115 5.2 3

0.1 2202 100.0 f

ARTIFICIAL ISLAND 10/05-12/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 150 FT DELTA T: (300-33FT)

LAPSE RATE:

LE -1.9 DEG C/1OOM CLASS A WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5

12. 6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 1

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 1

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 0

0.0 0

0.0 1

0.0 MEAN WIND SPEED:

MISSING:

18.3 0

r-,

r=

f=

r= T rz

=

r _

_77 Co -7 t77 777 CN7 O

r3" rC7 em77 cr7 lr:-

ARTIFICIAL ISLAND 10/05-12/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 150 FT DELTA T: (300-33FT)

LAPSE RATE: -1.8 TO -1.7 DEG C/1OOM CLASS B WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5

12. 6-18.5
18. 6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0

  • 0 0

0 0

0 0

0 0

0

.0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0

0. 0
0. 0 0.0 0.0 0.0 0.0 0.0 0.0 0.0*
0. 0
0. 0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

4 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.2 0.0 0.0 0.0 0.0 1

0 0

0 0

0 0

0 0

0 0

0 2

3 5

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0

0. 0 0.0 0.0 0.1 0.1 0.2 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

1 1

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 1

0 0

0 0

0 0

0 0

0 0

4 2

4 6

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 o.o 0.0 0.2 0.1 0.2 0.3 0.0 0

0.0 0.0 0

0.0 4

0.2 11 0.5 2

0.1 0

0.0 17 0.8 MEAN WIND SPEED:

15.4 MISSING:

0

ARTIFICIAL ISLAND 10/05-12/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 150 FT DELTA T: (300-33FT)

LAPSE RATE: -1.6 TO -1.5 DEG C/lOOM CLASS C WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5

7. 6-12.5 12.6-18.5
18. 6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 1

0 0

0 0

0 0

0 0

1 1

1 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 2

0 0

0 0

0 1

1 0

0 0

0 0

1 1

0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 9

4 7

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.4 0.2 0.3 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

3 3

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.0 0

0 0

0 0

0 0

0 0

0 0

0 1

1 0

0

0. 0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 2

0 1

0 0

0 1

1 0

0 0

2 11 9

11 I

0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.5 0.4 0.5 0.0 0

0.0 0

0.0 4

0.2 7

0.3 20 0.9 6

0.3 0.1 39 1.8 MEAN WIND SPEED:

MISSING:

15.1 0

r-7 G_-

ri___ r*

m r. _

rim rm r=

1 C7 C-77 CVIr C OO Or I

ARTIFICIAL ISLAND 10/05-12/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 150 FT DELTA T: (300-33FT)

LAPSE RATE: -1.4 TO -0.5 DEG C/1OOM CLASS D WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5

7. 6-12. 5 12.6-18.5
18. 6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 1

2 0

1 1

0 5

0 3

3 0

1 0

1 0.0 0.0 0.0 0.1 0.0 0.0 0.0 0.0 0.2 0.0 0.1 0.1 0.0 0.0 0.0 0.0 5

6 5

4

.7 2

3 7

a 9

12 11 12 8

5 2

0.2 0.3 0.2 0.2 0.3 0.1 0.1 0.3 0.4 0.4 0.6 0.5 0.6 0.4 0.2 0.1 21 45 24 7

0 4

1 12 19 12 6

14 9

22 11 11 1.0 2.1 1.1 0.3 0.0 0.2 0.0 0.6 0.9 0.6 0.3 0.6 0.4 1.0 0.5 0.5 19 15 3

2 0

1 3

5 7

7 11 12 45 33 59 17 0.9 0.7 0.1 0.1 0.0 0.0 0.1 0.2 0.3 0.3 0.5 0.6 2.1 1.5 2.7 0.8 7

10 6

0 0

0 1

2 4

1 8

1 26 29 27 5

0.3 0.5 0.3 0.0 0.0 0.0 0.0 0.1 0.2 0.0 0.4 0.0 1.2 1.3 1.2 0.2 0

0 0

0 0

0 5

1 0

0 0

0 12 1

12 1

0.0 0.0 0.0 0.0 0.0 0.0 0.2 0.0 0.0 0.0 0.0 0.0 0.6 0.0 0.6 0.0 52 76 39 15 7

8 14 27 43 29 40 41 104 94 114 37 2.4 3.5 1.8 0.7 0.3 0.4 0.6 1.2 2.0 1.3 1.8 1.9 4.8 4.3 5.3 1.7 0

0.0 18 0.8 106 4.9 218 10.1 239 11.0 127 5.9 32 1.5 740 34.2 MEAN WIND SPEED:

13.7 MISSING:

17

ARTIFICIAL ISLAND 10/05-12/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 150 FT DELTA T: (300-33FT)

LAPSE RATE: -0.4 TO 1.5 DEG C/1OOM CLASS E WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5

12. 6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 4

0.2 7

0.3 12 0

0.0 7

0.3 21 1

0.0 5

0.2 35 1

0.0 13 0.6 21 3

0.1 10 0.5 11 0

0.0 5

0.2 9

4 0.2 8

0.4 17 0

0.0 4

0.2 13 0

0.0 10 0.5 27 2

0.1 15 0.7 27 4

0.2 16 0.7 19 1

0.0 12 0.6 28 5

0.2 12 0.6 14 3

0.1 13 0.6 35 4

0.2 9

0.4 37 3

0.1 3

0.1 19 0.6 21 1.0 1.0 13 0.6 1.6 6

0.3 1.0 12 0.6 0.5 0

0.0 0.4 9

0.4 0.8 17 0.8 0.6 11 0.5 1.2 12 0.6 1.2 20 0.9 0.9 21 1.0 1.3 11 0.5.

0.6 20 0.9 1.6 51 2.4 1.7 87 4.0 0.9 22 1.0 12 0.6 19 0.9 4

0.2 2

0.1 0

0.0 0

0.0 5

0.2 3

0.1 1

0.0 6

0.3 6

0.3 1

0.0 3

0.1 8

0.4 30 1.4 9

0.4 1

0 0

0 0

0 9

2 6

2 0

0 0

0 10 3

0.0 0.0 0.0 0.0 0.0 0.0 0.4 0.'1 0.3 0.1 0.0 0.0 0.0 0.0 0.5 0.1 57 2.6 60 2.8 51 2.4 49 2.3 24 1.1 23 1.1 60 2.8 33 1.5 56 2.6 72 3.3 66 3.1 53 2.5 54 2.5 110 5.1 177 8.2 59 2.7 0

0.0 35 1.6 149 6.9 345 16.0 333 15.4 109 5.0 33 1.5 1004 46.4 MEAN WIND SPEED:

12.6 MISSING:

22 C

r C7:7 G rz 1

1 r=

IF=

FM C: CM r_

7 J

r-r

i.

r-7 r7 7

ll 7'-

ARTIFICIAL ISLAND 10/05-12/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 150 FT DELTA T: (300-33FT)

LAPSE RATE:

1.6 TO 4.0 DEG C/1OOM CLASS F WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 SUM PERCENT 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 1

0 0

1 0

0 4

2 0

2 2

2 1

1 0

1 0.0 0.0 0.0 0.0 0.0 0.0 0.2 0.1 0.0 0.1 0.1 0.1 0.0 0O.0 0.0 0.0 3

2 2

11 4

2 6

4 4

3 2

4 5.

4 2

5 0.1 0.1 0.1 0.5 0.2 0.1 0.3 0.2 0.2 0.1

0. 1 0.2 0.2 0.2 0.1 0.2 2

2 6

9 4

2 13 8

13 8

9 7

1 2

5 4

0.1 0.1 0.3 0.4 0.2 0.1 0.6 0.4 0.6 0.4 0.4 0.3 0.0 0.1 0.2 0.2 1

1 0

0 1

2 6

14 4

2 0

1 0

1 1

0 0.0 0.0 0.0 0.0 0.0 0.1 0.3 0.6 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 1

1 12 8

3 5

0 2

0 0

0 0

0.0 0.0 0.0 0.0 0.0 0.0 0.6 0.4 0.1 0.2 0.0 0.1 0.0 0.0 0.0 0.0 0

0 0

0 0

1 16 0

2 0

0 0

0 0

0 0

0.0 0.0 0.0 0.0 0.0 0.0 0.7 0.0 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 7

5 8

21 10 8

57 36 26 20 13 16 7

8 8

10 0.3 0.2 0.4 1.0 0.5 0.4 2.6 1.7 1.2 0.9 0.6 0.7 0.3 0.4 0.4 0.5 0

0.0 17 0.8 63 2.9 95 4.4 34 1.6 32 1.5 19 0.9 260 12.0 MEAN WIND SPEED:

12.1 MISSING:

0

ARTIFICIAL ISLAND 10/05-12/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 150 FT DELTA T: (300-33FT)

LAPSE RATE:

GT 4.0 DEG C/1OOM CLASS G WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5

12. 6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

2 0

2 0

0 1

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0

'0 1

1 2

0 1

2 1

1 0

0 3

0 0

0 0.0 0.0 0.0 0.0 0.1 0.0 0.0 0.1 0.0 0.0 0.0 0.0 0.1 0.0 0.0 0.0 0

0 0

6 0

2 10 5

4 0

0 0

6 1

0 0

0.0 0.0 0.0 0.3 0.0 0.1 0.5 0.2 0.2 0.0 0.0 0.0 0.3 0.0 0.0 0.0 0

0 0

0 0

1 5

8 0

1 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.2 0.4 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 11 3

0 0

0 0

0 0

0 0

0.0 0.0 0.0 0.0 0.0 0.0 0.5 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 21 1

0 0

0 0

0 0

0 0

0.0 0.0 0.0 0.0 0.0 0.0 1.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 1

7 2

5 48 21 5

2 1

0 19 1

0 0

0.0 0.0 0.0 0.3 0.1 0.2 2.2 1.0 0.2 0.1 0.0 0.0 0.4 0.0 0.0 0.0 0

0.0 5

0.2 12 0.6 34 1.6 15 0.7 14 0.6 22 1.0 102 4.7 MEAN WIND SPEED:

MISSING:

16.1 0

C_-

C=

fTC 7

r-"

Il7 r zl r-_

7 rr ir.-

r U -

171 ri_

7 r 1k X

ARTIFICIAL ISLAND 10/05-12/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 150 FT DELTA T: (300-33FT)

ALL STABILITY CLASSES WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 5

0.2 0

0.0 2

0.1 4

0.2 3

0.1 3

0.1 9

0.4 4

0.2 5

0.2 4

0.2 10 0.5 6

0.3 6

0.3 5

0.2 4

0.2 5

0.2 15 0.7 37 1.7 42 1.9 19 0.9 15 0.7 68 3.1 29 1.3 29 1.3 14 0.6 65 3.0 9

0.4 10 0.5 29 1.3 43 2.0 14 0.6 2

0.1 23 1.1 15 0.7 1

0.0 1

0.0 9

0.4 17 0.8 13 0.6 1

0.0 18 0.8 42 1.9 31 1.4 29 1.3 17 0.8 39 1.8 38 1.8 16 0.7 23 1.1 63 2.9 23 1.1 8

0.4 28 1.3 47 2.2 30 1.4 12 0.6 30 1.4 34 1.6 32 1.5 14 0.6 28 1.3 54 2.5 24 1.1 4

0.2 33 1.5 30 1.4 76 3.5 29 1.3 26 1.2 60 2.8 92 4.3 41 1.9 16 0.7 54 2.5 160 7.4 61 2.8 10 0.5 35 1.6 39 1.8 14 0.6 1

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 51 2.4 4

0.2 8

0.4 2

0.1 0

0.0 0

0.0 13 0.6 2

0.1 22 1.0 4

0.2 119 5.5 141 6.5 100 4.6 92 4.3 43 2.0 44 2.0 180 8.3 118 5.5 130 6.0 123 5.7 120 5.5 116 5.4 187 8.6 226 10.4 317 14.7 107 4.9 0

0.0 75 3.5 334 15.4 703 32.5 653 30.2 290 13.4 108 5.0 2163 100.0 MISSING HOURS:

45 MEAN WIND SPEED:

13.2

ARTIFICIAL ISLAND 10/05-12/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 150 FT DELTA T: (300-33FT)

DIRECTION VS SPEED ONLY WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5

7. 6-12.5
12. 6-18.5
18. 6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 5

0 2

4 3

3 9

4 5

4 10 6

6

.5 4

5 0.2 0.0 0.1 0.2 0.1 0.1 0.4 0.2 0.2 0.2 0.5 0.3 0.3 0.2 0.2 0.2 15 15 14 29 23 9

18 17 23 28 30 28 33 26 16 10 0.7 0.7 0.6 1.3 1.1 0.4 0.8 0.8 1.1 1.3 1.4 1.3 1.5 1.2 0.7 0.5 38 68 65 43 15 17 42 39 63 47 34 54 30 60 55 36 1.8 3.1 3.0 2.0 0.7 0.8 1.9 1.8 2.9 2.2 1.6 2.5 1.4 2.8 2.5 1.7 42 29 9

14 1

13 31 38 23 30 32 24 7 6 92 160 39 1.9 1.3 0.4 0.6 0.0 0.6 1.4 1.8 1.1 1.4 1.5 1.1 3.5 4.2 7.4 1.8 19 29 10 2

1 1

29 16 8

12 14 4

29 41 61 14 0.9 1.3 0.5 0.1 0.0 0.0 1.3 0.7 0.4 0.6 0.6 0.2 1.3 1.9 2.8 0.6 1

0 0

0 0

1 51 4

8 2

0 0

13 2

22 4

0.0 0.0 0.0 0.0 0.0 0.0 2.4 0.2 0.4 0.1 0.0 0.0 0.6 0.1 1.0 0.2 120 141 100 92 43 44 180 118 130 123 120 116 187 226 318 108 5.5 6.5 4.6 4.2 2.0 2.0 8.3 5.4 6.0 5.7 5.5 5.4 8.6 10.4 14.7 5.0 0

0.0 75 3.5 334 15.4 706 32.6 653 30.1 290 13.4 108 5.0 2166 100.0 MISSING HOURS:

42 MEAN WIND SPEED:

13.2 rzz=

r r

r C=

UT r7

=

r--

Ad UT U: c C

N--

r-l r7'-

lr~

7, 7-1 r7 07-I=

1r1

.7

=1

'7

-" I c7 v -71 ARTIFICIAL ISLAND 10/05-12/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 300 FT DELTA T: (300-33FT)

LAPSE RATE:

LE -1.9 DEG C/100M CLASS A WIND SPEED GROUPS (MPH)

.0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5

12. 6-18.5
18. 6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

a 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 1

0

0. 0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0o 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 1

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

o0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 1

0.0 0

0.0 1

0.0 MEAN WIND SPEED:

21.0 MISSING:

0

ARTIFICIAL ISLAND 10/05-12/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 300 FT DELTA T: (300-33FT)

LAPSE RATE: -1.8 TO -1.7 DEG C/lOOM CLASS B WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5

12. 6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0

.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

4 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.2 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 1

2 0

1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 1

2 5

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.2 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

1 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

4 2

5 5

1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.2 0.1 0.2 0.2 0.0 0

0.0 0

0.0 0

0.0 0.2 4

0.2 0.4 0.0 17 0.8 MEAN WIND SPEED:

MISSING:

17.3 0

9-_

rzz r--

r7 z

V18-r11 f C777

=

rzGm 1=: CC m

[

IC C771 r

FX O K3 E

C7 ARTIFICIAL ISLAND 10/05-12/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 300 FT DELTA T: (300-33FT)

LAPSE RATE: -1.6 TO -1.5 DEG C/100M CLASS C WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 1

0 0

0 0

0 0

0 0

1 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 2

0 0

0 0

0 2

0 0

0 0

1 1

1 1

1 0.1 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

2 5

2 1

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.2 0.1 0.0 0.0 0

0 0

0 0

0 0

0 0

0 0

0 2

6 8

0 0.0 0.0

0. 0
0. 0
0. 0 0.0
0. 0
0. 0
0. 0 0.0
0. 0
0. 0
0. 1
0. 3 0.4 0.0 0

0 0

0 0

0 0

0 0

0 0

0 1

1 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 2

0 1

0 0

0 2

0 0

0 0

4 9

10 10 1

0.1 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0.0 0.0 0.0 0.2 0.4 0.5 0.5 0.0 0.0 0

0.0 2

0.1 9

0.4 10 0.5 16 0.7 2

0.1 39 1.8 MEAN WIND SPEED:

16.8 MISSING:

0

ARTIFICIAL ISLAND 10/05-12/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 300 FT DELTA T: (300-33FT)

LAPSE RATE: -1.4 TO -0.5 DEG C/1OOM CLASS D WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5

7. 6-12.5
12. 6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 1

0 0

1 1

1 3

4 0

0 1

0 2

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.2 0.0 0.0 0.0 0.0 0.1I 0.0 3

5 3

7 2

2 1

5 5

5 10 13 8

10 3

2 0.1 0.2 0.1 0.3 0.1 0.1 0.0 0.2 0.2 0.2 0.5 0.6 0.4 0.5 0.1 0.1 13 38 19 10 2

1 9

3 11 9

5 18 11 17 10 7

0.6 1.7 0.9 0.5 0.1 0.0 0.4 0.1 0.5 0.4 0.2 0.8 0.5 0.8 0.5 0.3 16 21 5

2 0

1 1

9 12 17 6

9 29 33 38 15 0.7 1.0 0.2 0.1 0.0 0.0 0.0 0.4 0.5 0.8 0.3 0.4 1.3 1.5 1.7 0.7 15 14 6

0 0

0 3

2 4

3 10 3

37 31 53 5

0.7 0.6 0.3 0.0 0.0 0.0 0.1 0.1 0.2 0.1 0.5 0.i 1.7 1.4 2.4 0.2 0

2 1

0 0

0 5

2 0

0 2

0 20 16 25 3

0.0 0.1 0.0 0.0 0.0 0.0 0.2 0.1 0.0 0.0 0.1 0.0 0.9 0.7 1.1 0.1 4 7 80 35 19 4

5 20 22 35 38 33 43 106 107 131 32 2.1

3. 6 1.6 0.9 0.2 0.2 0.9 1.0 1.6 1.7 1.5 2.0 4.8 4.9 5.9 1.5 0

0.0 14 0.6 84 3.8 183 8.3 214 9.7 186 8.4 76 3.5 757 34.4 MEAN WIND SPEED:

MISSING:

15.6 0

r r zz 7-- r77 r -- r T rr ri-

_r" er7 r7" c7 F7 O7 r"

ARTIFICIAL ISLAND 10/05-12/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 300 FT DELTA T: (300-33FT)

LAPSE RATE: -0.4 TO 1.5 DEG C/lOOM CLASS E WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5

3. 6-7.5
7. 6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0:0 0.0 0.0 0.0 0

4 1

0 1

2 1

2 2

0 4

0 3

4 2

1 0.0 0.2 0.0 0.0 0.0 0.1 0.0 0.1 0.1 0.0 0.2 0.0 0.1 0.2 0.1 0.0 2

0 4

9 5

1 5

7 7

5 9

3 7

6 6

2 0.1 0.0 0.2 0.4 0.2 0.0 0.2 0.3 0.3 0.2 0.4 0.1 0.3 0.3 0.3 0.1 10 14 10 26 9

7 7

8 10 19 17 15 23 18 20 16 0.5 0.6 0.5 1.2 0.4 0.3 0.3 0.4 0.5 0.9 0.8 0.7 1.0 0.8 0.9 0.7 15 16 16 18 4

12 20 16 15 42 19 20 33 45 57 34 0.7 0.7 0.7 0.8 0.2 0.5 0.9 0.7 0.7 1.9 0.9 0.9 1.5 2.0 2.6 1.5 19 21 8

1 0

4 9

2 7

18 17 1

15 24 68 21 0.9 1.0 0.4 0.0 0.0 0.2 0.4 0.1 0.3 0.8 0.8 0.0 0.7 1.1 3.1 1.0 8

5 0

0 0

0 11 4

5 7

0 0

3 4

25 3

0.4 0.2 0.0 0.0 0.0 0.0 0.5 0.2 0.2 0.3 0.0 0.0 0.1 0.2 1.1 0.1 54 60 39 54 19 26 53 39 46 91 66 39 84 101 178 77 2.5 2.7 1.8 2.5 0.9 1.2 2.4 1.8 2.1 4.1 3.0 1.8 3.8 4.6 8.1 3.5 0

0.0 27 1.2 78 3.5 229 10.4 382 17.3 235 10.7 75 3.4 1026 46.6 MEAN WIND SPEED:

15.6 MISSING:

0

ARTIFICIAL ISLAND 10/05-12/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 300 FT DELTA T: (300-33FT)

LAPSE RATE:

1.6 TO 4.0 DEG C/1DOM CLASS F WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5

18. 6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

2 1

1 0

0 0

1 1

2 0

0 1

2 1

0 0.0 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0.0 0.0 0.1 0.0 0.0 4

2 1

4 6

1 3

3 1

3 3

2 3

3 0

1 0.2 0.1 0.0 0.2 0.3 0.0 0.1 0.1 0.0 0.1 0.1 0.1 0.1 0.1 0.0 0.0 4

1 3

5 2

1 4

11 9

5 10 5

1 2

1 4

0.2 0.0 0.1 0.2 0.1 0.0 0.2 0.5 0.4 0.2 0.5 0.2 0.0 0.1 0.0 0.2 2

0 3

3 3

1 8

10 7

14 8

7 4

2 2

3 0.1 0.0 0.1 0.1 0.1 0.0 0.4 0.5 0.3 0.6 0.4 0.3 0.2 0.1 0.1 0.1 1

0 0

0 1

1 1

11 12 2

1 0

0 0

1 0

0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.5 0.5 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 1

1 20 1

5 2

0 2

0 0

0 0

0.0 0.0 0.0 0.0 0.0 0.0 0.9 0.0 0.2 0.1 0.0 0.1 0.0 0.0 0.0 0.0 11 5

8 13 13 5

36 37 35 28 22 16 9

9 5

8 0.5 0.2 0.4 0.6 0.6 0.2 1.6 1.7 1.6 1.3 1.0 0.7 0.4 0.4 0.2 0.4 0

0.0 12 0.5 40 1.8 68 3.1 77 3.5 31 1.4 32 1.5 260 11.8 MEAN WIND SPEED:

MISSING:

14.9 0

C=_

F7; Ch7 r

=

O O= D-7 t-l r, r zt7r r m 7

u nrrn I-

-- U -- U -

91

W77 C'7 r7, er-FN-C7 C-r--

r=

i_-

r77 W7 7

77 7

l7 ARTIFICIAL ISLAND 10/05-12/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED PY ATMOSPHERIC STABILITY CLASS WIND: 300 FT DELTA T: (300-33FT)

LAPSE RATE:

GT 4.0 DEG C/1OOM CLASS G WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0

0 2

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 1

0 0

0 1

1 1

0 0~

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

1 0

7 2

0 0

3 7

3 1

2 2

0 0

0 0.0 0.0 0.0 0.3 0.1 0.0 0.0 0.1 0.3 0.1 0.0 0.1 0.1 0.0 0.0 0.0 0

0 0

0 0

1 3

2 6

3 0

0 6

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.3 0.1 0.0 0.0 0.3 0.0 0.0 0.0 0

0 0

0 0

0 4

3 6

1 0

0 2

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.2 0.1 0.3 0.0 0.0 0.0 0.1 0.0 0.0 0.0 0

0 0

0 0

0 12 19 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.5 0.9 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

1 0

7 3

1 19 27 22 8

2 2

10 0

0 0

0.0 0.0 0.0 0.3 0.1 0.0 0.9 1.2 1.0 0.4 0.1 0.1 0.5 0.0 0.0 0.0 0

0.,0 2

0.1 0.2 28 1.3 21 1.0 16 0.7 31 1.4 102 4.6 MEAN WIND SPEED:

19.8 MISSING:

0

ARTIFICIAL ISLAND 10/05-12/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 300 FT DELTA T: (300-33FT)

ALL STABILITY CLASSES WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5

18. 6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 O

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 0

0.0 6

0.3 3

0.1 1

0.0 1

0.0 3

0.1 2

0.1 4

0.2 8

0.4 6

0.3 4

0.2 0

0.0 5

0.2 6

0.3 5

0.2 1

0.0 9

0.4 29 1.3 33 1.5 35 1.6 8

0.4 7

0.3 54 2.5 37 1.7 35 1.6 7

0.3 9

0.4 32 1.5 24 1.1 14 0.6 1

0.0 20 0.9 48 2.2 23 1.0 1

0.0 0

0.0 14 0.6 15 0.7 7

0.3 1

0.0 1

0.0 4

0.2 9

0.4 15 0.7 5

0.2 1

0.0 9

0.4 22 1.0 32 1.5 17 0.8 48 2.2 15 0.7 25 1.1 37 1.7 18 0.8 26 1.2 14 0.6 37 1.7 40 1.8 29 1.3 10 0.5 14 0.6 36 1.6 76 3.5 24 1.1 9

0.4 23 1.0 33 1.5 33 1.5 28 1.3 2

0.1 19 0.9 45 2.0 38 1.7 4

0.2 2

0.1 18 0.8 38 1.7 78 3.5 57 2.6 24 1.1 19 0.9 38 1.7 84 3.8 63 2.9 22 1.0 9

0.4 32 1.5 98 4.5 136 6.2 50 2.3 5

0.2 28 1.3 53 2.4 26 1.2 6

0.3 114 5.2 146 6.6 83 3.8 93 4.2 39 1.8 37 1.7 130 5.9 125 5.7 138 6.3 165 7.5 123 5.6 108 4.9 220 10.0 232 10.5 330 15.0 119 5.4 2202 100.0 0

0.0 55 2.5 208 9.4 521 23.7 708 32.2 493 22.4 217 9.9 MISSING HOURS:

6 MEAN WIND SPEED:

15.8 U-r r77771 r_. r _ r-r__i rl C r-[ -

r ri

r7 r7 I

rm r7 r-r77 r-r:

r-U- I ARTIFICIAL ISLAND 10/05-12/05 JOINT DISTRIBUTION OF WIND DIRECTION AND SPEED BY ATMOSPHERIC STABILITY CLASS WIND: 300 FT DELTA T: (300-33FT)

DIRECTION VS SPEED ONLY WIND SPEED GROUPS (MPH) 0.0-0.5 0.6-3.5 3.6-7.5 7.6-12.5 12.6-18.5 18.6-24.5 GE 24.6 SUM PERCENT DIRECTION SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT SUM PERCENT N

NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW NW NNW 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

6 3

1 1

3 2

4 8

6 4

0 5

6 5

1 0.0 0.3 0.1 0.0 0.0 0.1 0.1 0.2 0.4 0.3 0.2 0.0 0.2 0.3 0.2 0.0 9

0.4 29 1.3 33 1.5 7

0.3 54 2.4 37 1.7 9

0.4 32 1.5 24 1.1 20 0.9 48 2.2 23 1.0 14 0.6 15 0.7 7

0.3 4

0.2 9

0.4 15 0.7 9

0.4 22 1.0 32 1.5 15 0.7 25 1.1 37 1.7 14 0.6 37 1.7 40 1.8 14 0.6 36 1.6 76 3.4 23 1.0 33 1.5 33 1.5 19 0.9 45 2.0 38 1.7 18 0.8 38 1.7 78 3.5 19 0.9 38 1.7 84 3.8 9

0.4 32 1.5 99 4.5 5

0.2 29 1.3 54 2.4 35 1.6 35 1.6 14 0.6 1

0.0 1

0.0 5

0.2 17 0.8 18 0.8 29 1.3 24 1.1 28 1.3 4

0.2 57 2.6 63 2.9 136 6.2 26 1.2 8

0.4 7

0.3 1

0.0 0

0.0 1

0.0 1

0.0 48 2.2 26 1.2 10 0.5 9

0.4 2

0.1 2

0.1 24 1.1 22 1.0 50 2.3 6

0.3 114 5.2 146 6.6 83 3.8

'93 4.2 39 1.8 37 1.7 130 5.9 125 5.7 138 6.3 165 7.5 123 5.6 108 4.9 220 10.0 232 10.5 331 15.0 121 5.5 0.0 55 2.5 208 9.4 522 23.7 710 32.2 493 22.4 217 9.8 2205 100.0 MISSING HOURS:

3 15.8 MEAN WIND SPEED:

2005 SGS AND HCGS RADIOACTIVE EFFLUENTS RELEASE REPORT APPENDIX B MPC DonA TA

2005 SGS AND HCGS RADIOACTIVE EFFLUENTS RELEASE REPORT APPENDIX F: Maximum Permissible Concentration (MPC) Values - Liquid Effluents The following radionuclide concentrations were obtained from 10 CFR 20 Appendix B, Table II, Column 2 as revised January 1, 1991 Table F-I: Maximum Permissible Concentrations Element Isotope Soluble Conc Insoluble Conc.

(,,Ci/ml)

(,,Ci/mi)

Actinium (89)

Ac-227 2E-6 3E-4 Ac-228 9E-5 9E-5 Americium (95)

Am-241 4E-6 3E-5 Am-242m 4E-6 9E-5 Am-242 IE-4 1E-4 Am-243 4E-6 3E-5 Am-244 5E-3 SE-3 Antimony (51)

Sb-122 3E-5 3E-5 Sb-124 2E-5 2E-5 Sb-125 IE-4 1E-4 Arsenic (33)

As-73 SE-4 SE-4 As-74 5E-5 5E-5 As-76 2E-5 2E-5 As-77 8E-5 8E-5 Astatine (85)

At-211 2E-6 7E-5 Barium (56)

Ba-131 2E-4 2E-4 Ba-140 3E-5 2E-5 Berkelium (97)

Bk-249 6E-4 6E-4 Bk-250 2E-4 2E-4 Beryllium (4)

Be-7 2E-3 2E-3 Bismuth (83)

Bi-206 4E-5 4E-5 Bi-207 6E-5 6E-5 Bi-210 4E-5 4E-5 Bi-212 4E-4 4E-4 Bromine (35)

Br-82 3E-4 4E-5 Cadmium (48)

Cd-109 2E-4 2E-4 Cd-lI 5m 3E-5 3E-5 Cd-1 15 3E-5 4E-5 Calcium (20)

Ca-45 9E-6 2E-4 Ca-47 5E-5 3E-5 Californium (98)

Cf-249 4E-6 2E-5 Cf-250 IE-5 3E-5 Cf-251 4E-6 3E-5 Cf-252 7E-6 7E-6 Cf-253 1E-4 1E-4 Cf-254 1E-7 1E-7

2005 SGS AND HCGS RADIOACTIVE EFFLUENTS RELEASE REPORT Table F-i (Continued)

Element Isotope Soluble Conc.

Insoluble Conc.

(ACi/ml)

(ACi/ml)

Carbon (6)

C-14 8E-4 Cerium (58)

Ce-141 9E-5 9E-5 Ce-143 4E-5 4E-5 Ce-144 IE-S IE-S Cesium (55)

Cs-131 2E-3 9E-4 Cs-134m 6E-3 IE-3 Cs-134 9E-6 4E-5 Cs-135 IE-4 2E-4 Cs-136 9E-5 6E-5 Cs-137 2E-5 4E-5 Chlorine (17)

Cl-36 8E-5 6E-5 CI-38 4E-4 4E-4 Chromium (24)

Cr-SI 2E-3 2E-3 Cobalt (27)

Co-57 SE-4 4E-4 Co-58m 3E-3 2E-3 Co-58 IE-4 9E-5 Co-60 5E-S 3E-5 Copper (29)

Cu-64 3E-4 2E-4 Curium (96)

Cm-242 2E-5 2E-5 Cm-243 5E-6 2E-5 Cm-244 7E-6 3E-5 Cm-245 4E-6 3E-5 Cm-246 4E-6 3E-5 Cm-247 4E-6 2E-5 Cm-248 4E-7 IE-6 Cm-249 2E-3 2E-3 Dysprosium (66)

Dy-165 4E-4 4E-4 Dy-166 4E-5 4E-5 Einsteinium (99)

Es-253 2E-5 2E-5 Es-254m 2E-5 2E-5 Es-254 IE-5 IE-5 Es-255 3E-5 3E-5 Erbium (68)

Er-169 9E-5 9E-5 Er-171 1E-4 1E-4 Europium (63)

Eu-152 (9.2 hrs) 6E-5 6E-5 Eu-152 (13 yrs) 8E-5 8E-5 Eu-154 2E-5 2E-5 Eu-155 2E-4 2E-4 Fermium (100)

Fm-254 1E-4 IE-4 Fm-255 3E-5 3E-5 Fm-256 9E-7 9E-7

2005 SGS AND HCGS RADIOACTIVE EFFLUENTS RELEASE REPORT Table F-i (Continued)

Element Isotope Soluble Conc.

Insoluble Conc.

(pCi/ml)

(PCi/ml)

Fluorine (9)

F-18 8E-4 5E-4 Gadolinium (64)

Gd-153 2E-4 2E-4 Gd-159 8E-5 8E-5 Gallium (31)

Ga-72 4E-5 4E-5 Germanium (32)

Ge-71 2E-3 2E-3 Gold (79)

Au-196 2E-4 1E-4 Au-198 5E-5 5E-5 Au-l99 2E-4 2E-4 Hafnium (72)

Hf-181 7E-5 7E-5 Holmium (67)

Ho-166 3E-5 3E-5 Hydrogen (3)

H-3 3E-3 3E-3 Indium (49)

In-i 13m IE-3 IE-3 In-114m 2E-5 2E-5 In-i15m 4E-4 4E-4 In-115 9E-5 9E-5 Iodine (53) 1-125 2E-7 2E-4 1-126 3E-7 9E-5 I-129 6E-8 2E-4 I-131 3E-7 6E-5 1-132 8E-6 2E-4 I-133 IE-6 4E-5 1-134 2E-5 6E-4 1-135 4E-6 7E-5 Iridium (77)

Ir-l90 2E-4 2E-4 Ir-192 4E-5 4E-5 Ir-194 3E-5 3E-5 Iron (26)

Fe-55 8E1-4 2E-3 Fe-59 6E-5 5E-5 Lanthanum (57)

La-140 2E-5 2E-5 Lead (82)

Pb-203 4E-4 4E-4 Pb-210 IE-7 2E-4 Pb-212 2E-5 2E-5 Lutetium (71)

Lu-177 IE-4 IE-4 Manganese (25)

Mn-52 3E-5 3E-5 Mn-54 IE-4 IE-4 Mn-56 IE-4 IE-4 Mercury (80)

Hg-197m 2E-4 2E-4 Hg-197 3E-4 5E-4 Hg-203 2E-5 IE-4 Molybdenum (42)

Mo-99 2E-4 4E-5

2005 SGS AND HCGS RADIOACTIVE EFFLUENTS RELEASE REPORT Table F-I (Continued)

Element Isotope Soluble Conc.

Insoluble Conc.

_(KC-iml)

(ci/Cml)

Neodymium (60)

Nd-144 7E-5 8E-5 Nd-147 6E-5 6E-5 Nd-149 3E-4 3E-4 Neptunium (93)

Np-237 3E-6 3E-5 Np-239 IE-4 IE-4 Nickel (28)

Ni-59 2E-4 2E-3 Ni-63 3E-5 7E-4 Ni-65 IE-4 1E-4 Niobium (41)

Nb-93m 4E-4 4E-4 Nb-95 IE-4 IE-4 Nb-97 9E-4 9E-4 Osmium (76)

Os-185 7E-5 7E-5 Os-191m 3E-3 2E-3 Os-191 2E-4 2E-4 Os-193 6E-5 5E-5 Palladium (46)

Pd-103 3E14 3E-4 Pd-109 9E-5 7E-5 Phosphorus (15)

P-32 2E-5 2E-5 Platinum (78)

Pt-191 IE-4 IE-4 Pt-193m IE-3 IE-3 Pt-193 9E-4 2E-3 Pt-197m IE-3 9E-4 Pt-197 IE-4 IE-4 Plutonium (94)

Pu-238 5E-6 3E-5 Pu-239 5E-6 3E-5 Pu-240 5E-6 3E-5 Pu-241 2E-4 IE-3 Pu-242 5E-6 3E-5 Pu-243 3E-4 3E-4 Polonium (84)

Po-210 7E-7 3E-5 Potassium (19)

K-42 3E-4 2E-5 Praseodymium(59)

Pr-142 3E-5 3E-5 Pr-143 5E-5 5E-5 Promethium (61)

Pm-147 2E-4 2E-4 Pm-149 4E-5 4E-5 Protactinium(91)

Pa-230 2E-4 2E-4 Pa-231 9E-7 2E-5 Pa-233 IE-4 iE-4

2005 SGS AND HCGS RADIOACTIVE EFFLUENTS RELEASE REPORT Table F-1 (Continued)

Element Isotope Soluble Conc.

Insoluble Conc.

(ACi/ml)

(pCi/ml)

Radium (88)

Ra-223 7E-7 4E-6 Ra-224 2E-6 5E-6 Ra-226 3E-8 3E-5 Ra-228 3E-8 3E-5 Rhenium (75)

Re-183 6E-4 3E-4 Re-186 9E-5 5E-5 Re-187 3E-3 2E-3 Re-188 6E-5 3E-5 Rhodium (45)

Rh-103m IE-2 IE-2 Rh-105 IE-4 IE-4 Rubidium (37)

Rb-86 7E-5 2E-5 Rb-87 IE-4 2E-4 Ruthenium (44)

Ru-97 4E-4 3E-4 Ru-103 8E-5 8E-5 Ru-105 1E-4 1E-4 Ru-106 IE-5 IE-5 Samarium (62)

Sm-147 6E-5 7E-5 Sm-151 4E-4 4E-4 Sm-153 8E-5 8E-5 Scandium (21)

Sc-46 4E-5 4E-5 Sc-47 9E-5 9E-5 Sc-48 3E-5 3E-5 Selenium (34)

Se-75 3E-4 3E-4 Silicon (14)

Si-31 9E-4 2E-4 Silver (47)

Ag-105 IE-4 IE-4 Ag-ll0m 3E-5 3E-5 Ag-lll 4E-5 4E-5 Sodium (11)

Na-22 4E-5 3E-5 Na-24 2E-4 3E-5 Strontium (38)

Sr-85m 7E-3 7E-3 Sr-85 1E-4 2E-4 Sr-89 3E-6 3E-5 Sr-90 3E-7 4E-5 Sr-91 7E-5 5E-5 Sr-92 7E-5 6E-5 Sulfur (16)

S-35 6E-5 3E-4 Tantalum (73)

Ta-182 4E-5 4E-5

2005 SGS AND HCGS RADIOACTIVE EFFLUENTS RELEASE REPORT Table F-1 (Continued)

Element Isotope Soluble Conc.

Insoluble Conc. (,Citml)

(RCi/ml)

Technetium (43)

Tc-96m IE-2 1E-2 Tc-96 1E-4 SE-S Tc-97m 4E-4 2E-4 Tc-97 2E-3 8E-4 Tc-99m 6E-3 3E-3 Tc-99 3E-4 2E-4 Tellurium (52)

Te-125m 2E-4 1E-4 Te-127m 6E-5 5E-5 Te-127 3E-4 2E-4 Te-129m 3E-S 2E-5 Te-129 8E-4 SE4 Te-131m 6E-5 4E-5 Te-132 3E-5 2E-5 Terbium (65)

Tb-160 4E-5 4E-5 Thallium (81)

Tl-200 4E-4 2E-4 Tl-201 3E-4 2E-4 Tl-202 1E-4 7E-5 TI-204 1E4 6E-5 Thorium (90)

Th-227 2E-5 2E-5 Th-228 7E-6 IE-5 Th-230 2E-6 3E-5 Th-231 2E-4 2E-4 Th-232 2E-6 4E-S Th-natural 2E-6 2E-5 Th-234 2E-5 2E-5 Thulium (69)

Tm-170 SE-S SE-5 Tm-171 1SE4 SE-4 Tin (50)

Sn-113 9E-5 8E-5 Sn-124 2E-5 2E-5 Tungsten (74)

W-181 4E-4 3E-4 W-185 IE-4 1E4 W-187 7E-5 6E-5 Uranium (92)

U-230 5E-6 5E1-6 U-232 3E-5 3E-S U-233 3E-5 3E-5 U-234 3E-5 3E-S U-235 3E-5 3E-5 U-236 3E-5 3E-5 U-238 4E-5 4E-S U-240 3E-5 3E-5 U-natural 3E-5 3E-S

2005 SGS AND HCGS RADIOACTIVE EFFLUENTS RELEASE REPORT Table F-I (Continued)

Element Isotope Soluble Conc.

Insoluble Conc. (pCi/ml)

(oCi/ml)

Vanadium (23)

V-48 3E-5 3E-5 Ytterbium (70)

Yb-175 IE-4 IE-4 Yttrium Y-90 2E-5 2E-5 Y-91m 3E-3 3E-3 Y-91 3E-5 3E-5 Y-92 6E-5 6E-5 Y-93 3E-5 3E-5 Zinc (30)

Zn-65 IE-4 2E-4 Zn-69m 7E-5 6E-5 Zn-69 2E-3 2E-3 Zirconium (40)

Zr-93 8E-4 8E-4 Zr-95 6E-5 6E-5 Zr-97 2E-5 2E-5 Any single radio-nuclide not 3E-6 3E-6 listed above with decay mode other than alpha emission or spontaneous fission and with radio -

active half-life greater than 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> Any single radio-nuclide 3E-8 3E-8 not listed above, which decays by alpha emission or spontaneous fission.

Notes:

1. If the identity of any radionuclide is not known, the limiting values for purposes of this table shall be: 3E-8 gCi/ml.
2. If the identity and concentration of each radionuclide are known, the limiting values should be derived as follows:

Determine, for each radionuclide in the mixture, the ratio between the quantity present in the mixture and the limit otherwise established in Appendix B for the specific radionuclide not in a mixture. The sum of such ratios for all the radionuclides in the mixture may not exceed "I" (i.e. "unity").