Tech Spec Pages for Amendments 272 and 154 Applicability of Westinghouse Topical Report WCAP-12945-O-A, Volume 1 (Revision 2) 1996 and Volume 2-5 (Revision 1), Code Qualification Document for Best Estimate Loca
ML060390085
Person / Time
Site: Beaver Valley
(DPR-066, NPF-073)
Issue date: 02/06/2006
From:
NRC/NRR/ADRO
To:
References
TAC MC4647, TAC MC4648
Download: ML060390085 (2)


Text

ADMINISTRATIVE CONTROLS CORE OPERATING LIMITS REPORT (Continued)

b.

The analytical methods used to determine the core operating limits shall be those previously reviewed and approved by the NRC, specifically those described in the following documents:

WCAP-9272-P-A, "WESTINGHOUSE RELOAD SAFETY EVALUATION METHODOLOGY," July 1985 (Westinghouse Proprietary).

WCAP-8745-P-A, Design Bases for the Thermal Overtemperature AT and Thermal Overpower AT trip functions, September 1986.

WCAP-12945-P-A, Volume 1 (Revision 2) and Volumes 2 through 5

(Revision 1),

"Code Qualification Document for Best Estimate LOCA Analysis,"

March 1998 (Westinghouse Proprietary).

WCAP-8385, "POWER DISTRIBUTION CONTROL AND LOAD FOLLOWING PROCEDURES -

TOPICAL REPORT."

September 1974 (Westinghouse Proprietary).

T. M. Anderson to K. Kniel (Chief of Core Performance Branch, NRC) January 31, 1980 --

Attachment:

Operation and Safety Analysis Aspects of an Improved Load Follow Package.

NUREG-0800, Standard Review Plan, U.S. Nuclear Regulatory Commission, Section 4.3, Nuclear Design, July 1981.

Branch Technical Position CPB 4.3-1, Westinghouse Constant Axial Offset Control (CAOC), Rev. 2, July 1981.

WCAP-12610-P-A, "VANTAGE+ Fuel Assembly Reference Core Report," April 1995 (Westinghouse Proprietary).

As described in reference documents listed above, when an initial assumed power level of 102% of rated thermal power is specified in a previously approved method, 100.6% of rated thermal power may be used when input for reactor thermal power measurement of feedwater flow is by the leading edge flow meter (LEFM).

Caldon, Inc.

Engineering Report-80P, "Improving Thermal Power Accuracy and Plant Safety While Increasing Operating Power Level Using the LEFMIITM System," Revision 0, March 1997.

BEAVER VALLEY -

UNIT 1 6-19 Amendment No.272

ADMINISTRATIVE CONTROLS REPORTING REQUIREMENTS (ContinuejL WCAP-8745-P-A, "Design Bases for the Thermal Overtemperature AT and Thermal Overpower AT Trip Functions," September 1986.

WCAP-12945-P-A, Volume 1 (Revision 2) and Volumes 2 through 5 (Revision 1),

"Code Qualification Document for Best Estimate LOCA Analysis,"

March 1998 (Westinghouse Proprietary).

WCAP-8385, "POWER DISTRIBUTION CONTROL AND LOAD FOLLOWING PROCEDURES -

TOPICAL REPORT." September 1974 (Westinghouse Proprietary).

T. M. Anderson to K. Kniel (Chief of Core Performance Branch, NRC) January 31, 1980 --

Attachment:

Operation and Safety Analysis Aspects of an Improved Load Follow Package.

NUREG-0800, Standard Review Plan, U.S. Nuclear Regulatory Commission, Section 4.3, Nuclear Design, July 1981.

Branch Technical Position CR8 4.3-1, Westinghouse Constant Axial Offset Control (CAOC), Rev. 2, July 1981.

WCAP-12610-P-A, "VANTAGE+ Fuel Assembly Reference Core Report," April 1995 (Westinghouse Proprietary).

As described in reference documents listed above, when an initial assumed power level of 102% of rated thermal power is specified in a previously approved method, 100.6% of rated thermal power may be used when input for reactor thermal power measurement of feedwater flow is by the leading edge flow meter (LEFM).

Caldon, Inc.

Engineering Report-80P, "Improving Thermal Power Accuracy and Plant Safety While Increasing Operating Power Level Using the LEFMVTM System," Revision 0, March 1997.

Caldon, Inc.

Engineering Report-160P, "Supplement to Topical Report ER-80P:

Basis for a Power Uprate With the LEFM\\ TM System," Revision 0, May 2000.

BEAVER VALLEY - UNIT 2 6-2 0 Amendment No.154