ML053570309
| ML053570309 | |
| Person / Time | |
|---|---|
| Site: | Susquehanna |
| Issue date: | 12/09/2005 |
| From: | Susquehanna |
| To: | Document Control Desk, Office of Nuclear Reactor Regulation |
| References | |
| Download: ML053570309 (92) | |
Text
Dec. 09, 2005 Page I of 1 MANUAL HARD COPY DISTRIBUTION DOCUMENT TRANSMITTAL 2005-53618 USER INFORMATIONie Name H*
E M Address:
Phone#:
54-319 TRAN ITTAL INFORMATION:
EMPL#:028401 CA#:0363 TO:
_l"*'T O
J.-.*
12/09/2005 LOCATION:trUSNRC777" FROM:
NUCLEA'RRECORDS DOCUMENT CONTROL CENTER (NUCSA-2)
THE FOLLOWING CHANGES HAVE OCCURRED TO THE HARDCOPY OR ELECTRONIC MANUAL ASSIGNED TO YOU.
HARDCOPY USERS MUST ENSURE THE DOCUMENTS PROVIDED MATCH THE INFORMATION ON THIS TRANSMITTAL.
WHEN REPLACING THIS MATERIAL IN YOUR HARDCOPY MANUAL, ENSURE THE UPDATE DOCUMENT ID IS THE SAME DOCUMENT ID YOU'RE REMOVING FROM YOUR MANUAL.
TOOLS FROM THE HUMAN PERFORMANCE TOOL BAG SHOULD BE UTILIZED TO ELIMINATE THE CHANCE OF ERRORS.
ATTENTION: "REPLACE" directions do not affect the Table of Contents, Therefore no OC will be issued with the updated material.
TSB1 -
TECHNICAL SPECIFICATION BASES UNIT 1 MANUAL REMOVE MANUAL TABLE OF CONTENTS DATE: 12/06/2005 ADD MANUAL TABLE OF CONTENTS DATE: 12/08/2005 CATEGORY:
ID:
TEXT REMOVE:
DOCUMENTS TYPE: TSB1 3.6.1.3 REV:2 ADD:
REV: 3 CATEGORY:
ID:
TEXT REMOVE:
DOCUMENTS TYPE: TSB1 LOES REV:66 ADD:
REV: 67 ANY DISCREPANCIES WITH THE MATERIAL PROVIDED, CONTACT DCS @ X3107 OR X3136 FOR ASSISTANCE. UPDATES FOR HARDCOPY MANUALS WILL BE DISTRIBUTED WITHIN 5 DAYS IN ACCORDANCE WITH DEPARTMENT PROCEDURES.
PLEASE MAKE ALL CHANGES AND ACKNOWLEDGE COMPLETE IN YOUR NIMS INBOX UPON COMPLETION OF UPDATES.
FOR ELECTRONIC MANUAL
- USERS, ELECTRONICALLY REVIEW THE APPROPRIATE DOCUMENTS AND ACKNOWLEDGE COMPLETE IN YOUR NIMS INBOX.
f
(_J~U rE(
l.....
A I
I e-SSES MA.NUAL 4n Manual Name: TSB1 Manual
Title:
TECHNICAL SPECIFICATION BASES UNIT 1 MANUAL Table Of Contents Issue Date:
12/08/2005 Procedure Name Rev TEXT LOES 67
Title:
LIST OF EFFECTIVE SECTIONS Issue Date 12/08/2005 Change ID Change Number TEXT TOC
Title:
TABLE OF CONTENTS 7
04/18/2005 TEXT 2.1.1 1
04/27/2004
Title:
SAFETY LIMITS (SLS)
REACTOR CORE SLS TEXT 2.1.2
Title:
SAFETY LIMITS (SLS)
TEXT 3.0 w
Title:
LIMITING CONDITION 0
.11/15/2002 REACTOR COOLANT SYSTEM 1
04/18/.2005 \\.
FOR OPERATIObW(LCO)-APPi
- SURE SL TEXT 3.1.1 0 /0
- 1ll5/2002
Title:
REACTIVITY CONTROL SYSTEMS..SHUTDOWN MARGIN (SDM)
TEXT 3.1.2 5/2002
Title:
REACTIVITY CONTROL 2 SYSTEMS REACTIVITY ANOMALIES TEXT 3.1.3 1
07/06/2005
Title:
REACTIVITY CONTROL SYSTEMS CONTROL ROD OPERABILI TY TEXT 3.1.4
Title:
REACTIVITY CONTROL SYS TEXT 3.1.5
Title:
REACTIVITY TEXT 3.1.6
Title:
REACTIVITY 1
07/06/2005 TEMS CONTROL ROD' SCRAM TIMES 1
07/06/2005 TEMS CONTROL ROD SCRAM ACCUMULATORS 1
02/17/2005 TEMS ROD PATTERN CONTROL CONTROL SYS' CONTROL SYS' Pagel of 8 Report Date: 12/08/05 Page I of 8
Report Date: 12/08/05
SSES MANUAL I
I I )
Manual Name: TSB1 I
Manual
Title:
TECHNICAL SPECIFICATION BASES UNIT. 1MANUAL -'
~(9 TEXT 3.1.7 1
Title:
REACTIVITY CONTROL SYSTEMS 08/30/2005 STANDBY LIQUID CONTROL (SLC)
SYSTEM TEXT 3.1.8
Title:
REACTIVITY CONTROL 1
10/19/2005 SYSTEMS SCRAM DISCHARGE VO.L:
UME;(ISDVVEN DRAIN VAL VE VOLUME-"(SDV) VENT AND DRAIN VALVES TEXT 3.2.1 0
Title:
POWER DISTRIBUTION LIMITS 11/15/2002 AVERAGE PLANAR LINEAR HEAT GENERATION RATE (APLHGR)
TEXT 3.2.2
Title:
POWER DISTRIBUTION 0.
LIMITS 11/15/2002 MINIMUM CRITICAL POWER RATIO (MCPR)
- 11/15/2002 LINEAR HEAT GENERATION RATE (LHGR)
TEXT 3.2.3 0.
Title:
POWER DISTRTBUTION LIMITS "EXT 3.2.4 1
07/06/2005
Title:
POWER DISTRIBUTION LIMITS AVERAGE POWER RANGE MONITOR (APRM)
GAIN AND SETPOINTS TEXT 3.3.1.1 2
07/06/2005
Title:
INSTRUMENTATION REACTOR PROTECTION SYSTEM.(RPS) INSTRUMENTATION TEXT 3.3.1.2 0
11/15/2002
Title:
INSTRUMENTATION SOURCE RANGE MONITOR (SRM) INSTRUMENTATION TEXT 3.3.1.3
Title:
OPRM INSTRUMENTATION 0
11/22/2004 TEXT 3.3.2.1 1
02/17/2005
Title:
INSTRUMENTATION CONTROL ROD BLOCK INSTRUMENTATION TEXT 3.3.2.2 0
11/15/2002-
Title:
INSTRUMENTATION FEEDWATER -
MAIN TURBINE HIGH WATER LEVEL TRIP INSTRUMENTATION TEXT 3.3.3.1 2
,07/06/2005
Title:
INSTRUMENTATION POST ACCIDENT MONITORING (PAM) INSTRUMENTATION (9
Page2
- of8 Report Date: 12/08/05 Page 2 h,
of.8,,_
Report Date: 12/08/05-:'
SSES MANUAL I Manual Name:
TSB1 Manual
Title:
TECHNICAL SPECIFICATION BASES UNIT 1 MANUAL TEXT 3.3.3.2 1
04/18/2005
Title:
INSTRUMENTATION REMOTE SHUTDOWN SYSTEM TEXT 3.3.4.1 0
11/15/2002
Title:
INSTRUMENTATION END OF CYCLE RECIRCULATION PUMP TRIP (EOC-RPT) INSTRUMENTATION TEXT 3.3.4.2 0
11/15/2002
Title:
INSTRUMENTATION ANTICIPATED TRANSIENT WITHOUT SCRAM RECIRCULATION PUMP TRIP (ATWS-RPT) INSTRUMENTATION TEXT 3.3.5.1
Title:
INSTRUMENTATION TEXT 3;3.5.2
Title:
INSTRUMENTATION EXT 3.3.6.1
Title:
INSTRUMENTATION TEXT 3.3.6.2
Title:
INSTRUMENTATION TEXT 3.3.7.1
Title:
INSTRUMENTATION INSTRUMENTATION TEXT 3.3.8.1
Title:
INSTRUMENTATION TEXT 3.3.8.2
Title:
INSTRUMENTATION TEXT 3.4.1
Title:
TEXT 3.4.2
Title:
- 2.
07/06/2005 EMERGENCY CORE COOLING SYSTEM (ECCS) INSTRUMENTATION 0
11/15/2002 REACTOR CORE ISOLATION COOLING (RCIC) SYSTEM INSTRUMENTATION
- 1.
11/09/2004 PRIMARY CONTAINMENT ISOLATION INSTRUMENTATION
.1 11/09/2004-SECONDARY CONTAINMENT ISOLATION INSTRUMENTATION 0
11/15/2002 CONTROL ROOM EMERGENCY OUTSIDE AIR SUPPLY (CREOAS) SYSTEM 1
09/02/2004 LOSS OF POWER (LOP) INSTRUMENTATION': v.
0 11/15/2002 REACTORPROTECTION SYSTEM (RPS)'ELECTRIC POWER MONITORING 2
11/22/2004 SYSTEM :(RCS) RECIRCULATION.LOOPS OPERATING
- 0.
11/15/2002 SYSTEM (RCS) JET PUMPS Page 3 of 8 Report Date: 12/08/05 Page 3 of 8 Report Date: 12/08/05
SSES MANUAL5 s I Manual Name:
TSB1 Manual
Title:
TECHNICAL SPECIFICATION BASES UNIT 1 MANUAL'.'-
TEXT 3.4.3 0
11/15/2002
Title:
REACTOR COOLANT SYSTEM (RCS) SAFETY/RELIEF VALVES (S/RVS)'
TEXT 3.4.4 0
11/15/2002
Title:
REACTOR COOLANT SYSTEM (RCS) RCS.OPERATIONAL LEAKAGE TEXT 3.4.5 0
11/15/2002
Title:
REACTOR COOLANT SYSTEM (RCS) RCS4PRESSURE ISOLATION VALVE (PIV) LEAKAGE TEXT 3.4.6 1-04/18/2005
Title:
REACTOR COOLANT SYSTEM.(RCS).'RCS LEAKAGE DETECTION INSTRUMENTATION TEXT 3.4.7
Title:
04/18/2005 SYSTEM (RCS) RCS SPECIFIC ACTIVITY BEXT 3.4.8
Title:
REACTOR COOLANT HOT SHUTDOWN TEXT 3.4.9
Title:
REACTOR COOLANT COLD SHUTDOWN TEXT 3.4.10
Title:
REACTOR COOLANT TEXT 3.4.11
Title:
REACTOR COOLANT TEXT 3.5.1 1
04/18/2005 SYSTEM ARCS) RESIDUAL HEAT REMOVAL (RHR) SHUTDOWN COOLING-SYSTE.b.
0 11/i5/2002 SYSTEM (RCS) RESIDUAL'.HEAT.REMOVAL (RHR) SHUTDOWN COOLING-SYSTEM 0
11/15/2002 SYSTEM (RCS) RCS'PRESSURE AND TEMPERATURE, (P/T) LIMITS 0
11/15/2002 SYSTEM (RCS) REACTOR STEAM DOME PRESSURE 1
04/18/2005
Title:
EMERGENCY CORE COOLING SYSTEMS (ECCS)'AND'REACTOR CORE ISOLATION COOLING (RCIC)
SYSTEM ECCS -
OPERATING TEXT 3.5.2 0
11/15/2002
Title:
EMERGENCY CORE COOLING SYSTEMS'(ECCS) AND REACTOR CORE ISOLATION COOLING (RCIC)
SYSTEM ECCS -
SHUTDOWN TEXT 3.5.3 1
04/18/2005
Title:
EMERGENCY CORE'COOLING SYSTEMS (ECCS)
AND REACTOR CORE ISOLATION 'COOLING SYSTEM RCIC SYSTEM (RCIC),(9 Page4 of 8y Report Date: 12/08/05 Page 4 :o of 8 -
Report Date: 12/08/05:-f
C.
SSES MANUAL I Manual Name: TSB1 Manual
Title:
TECHNICAL SPECIFICATION BASES UNIT 1 MANUAL TEXT 3.6.1.1
Title:
CONTAINMENT SYSTEMS 0
11/15/2002 PRIMARY-CONTAINMENT TEXT 3.6.1.2 0
11/15/2002
Title:
CONTAINMENT SYSTEMS PRIMARY CONTAINMENT AIR LOCK j
I TEXT 3.6.1.3
Title:
CONTAINMENT SYSTEMS TEXT 3.6.1.4
Title:
CONTAINMENT SYSTEMS TEXT 3.6.1.5
Title:
CONTAINMENT SYSTEMS 3
12/08/2005 PRIMARY CONTAINMENT ISOLATION VALVES (PCIVS)
- 0.
11/15/2002 CONTAINMENT PRESSURE 1
10/05/2005 DRYWELL AIR TEMPERATURE
-EXT 3.6.1.6
Title:
CONTAINMENT SYSTEMS
- 0.
11/15/2002 SUPPRESSION CHAMBER-TO-DRYWELL VACUUM BREAKERS TEXT 3.6.2.1
Title:
CONTAINMENT TEXT 3.6.2.2
Title:
CONTAINMENT TEXT 3.6.2.3
Title:
CONTAINMENT 0
11/15/2002 SYSTEMS SUPPRESSION.SPOOL AVERAGE TEMPERATURE 0
11/15/2002 SYSTEMS SUPPRESSION POOL WATER LEVEL 0
11/15/2002i;.'
SYSTEMS RESIDUAL HEAT REMOVAL (RHR)
SUPPRESSION POOL: COOLING 0
11/15/2002
.SYSTEMS RESIDUAL HEAT REMOVAL (RHR)
SUPPRESSION POOL SPRAY 04/18/2005 SYSTEMS PRIMARY CONTAINMENT HYDROGEN RECOMBINERS 1
04/18/2005,-
SYSTEMS DRYWELL AIR FLOW SYSTEM TEXT 3.6.2.4
Title:
CONTAINMENT TEXT 3.6.3.1
Title:
CONTAINMENT TEXT 3.6.3.2
Title:
CONTAINMENT PageS of
- 8.
Report Date: 12/08/05 Page 5 of 8 I
Report Date: 12/08/05
SSES MANUAL m
Manual Name:
TSB1 Manual
Title:
TECHNICAL SPECIFICATION BASES UNIT 1 MANUAL
(
. I.
X TEXT 3.6.3.3 0
11/15/2002
Title:
CONTAINMENT SYSTEMS PRIMARY CONTAINMENT OXYGEN CONCENTRATION TEXT 3.6.4.1
Title:
CONTAINMENT 4
10/24/2005 SYSTEMS SECONDARYCONTAINMENT:
I TEXT 3.6.4.2
Title:
CONTAINMENT 2
01/03/2005 SYSTEMS SECONDARY CONTAINMENT'ISOLATION VALVES (SCIVS)
TEXT 3.6.4.3
Title:
CONTAINMENT
- 3.
10/24/2005 SYSTEMS STANDBY GAS TREATLMENrT (SGT)' SYSTEM TEXT 3.7.1 0
11/15/2002
Title:
PLANT SYSTEMS RESIDUAL HEAT REMOVAL SERVICE WATER (RHRSW)
SYSTEM ULTIMATE HEAT SINK (UHS) i
.I I'
I AND THE
)-
I C
'EXT 3.7.2 1
11/09/2004
Title:
PLANT SYSTEMS EMERGENCY SERVICE WATER (ESW)
SYSTEM TEXT 3.7.3 0
11/15/2002-
Title:
PLANT SYSTEMS CONTROL ROOM EMERGENCY OUTSIDE AIR SUPPLY (CREOAS) SYSTEM TEXT 3.7.4 0
11/15/2002
Title:
PLANT SYSTEMS CONTROL ROOM FLOOR COOLING SYSTEM TEXT 3.7.5 0
11/15/2002-
Title:
PLANT'SYSTEMS'MAIN CONDENSER OFFGAS TEXT 3.7.6 1
01/17/2005
Title:
PLANT SYSTEMS MAIN TURBINE BYPASS SYSTEM TEXT 3.7.7 0
11/15/2002
Title:
PLANT SYSTEMS-SPENT FUEL STORAGE POOL WATER LEVEL.
TEXT 3.8.1 3
10/05/2005
Title:
ELECTRICAL POWER SYSTEMS AC SOURCES -
OPERATING Q},
Page6 of.8 Report Date: 12/08/05 Page-6..., fof.8 ---
Report Date: -12/08/05 '
SSES EAnUAL Manual Name:
TSB1 Manual
Title:
TECHNICAL SPECIFICATION BASES UNIT 1 MANUAL TEXT 3.8.2 0
11/15/2002
Title:
ELECTRICAL POWER SYSTEMS AC SOURCES -
SHUTDOWN TEXT 3.8.3 0
11/15/2002
Title:
ELECTRICAL POWER SYSTEMS DIESEL FUEL OIL, LUBE OIL, AND STARTING AIR TEXT 3.8.4 0
11/15/2002
Title:
ELECTRICAL POWER SYSTEMS DC SOURCES -
OPERATING TEXT 3.8.5
- 0.
11/15/2002
Title:
ELECTRICAL-POWER SYSTEMS DC SOURCES -
SHUTDOWN TEXT 3.8.6 0
11/15/2002
Title:
ELECTRICAL POWER SYSTEMS BATTERY CELL PARAMETERS TEXT 3.8.7 1
10/05/2005.
(n
Title:
ELECTRICAL POWER SYSTEMS DISTRIBUTION SYSTEMS OPERATING TEXT 3.8.8
-0 11/15/2002
Title:
ELECTRICAL POWER SYSTEMS DISTRIBUTION SYSTEMS SHUTDOWN TEXT 3.9.1 0
11/15/2002
Title:
REFUELING OPERATIONS REFUELING EQUIPMENT INTERLOCKS TEXT 3.9.2 0
11/15/2002 E
Title:
.REFUELING OPERATIONS REFUEL POSITION'.ONE-ROD-OUT INTERLOCK TEXT 3.9.3
Title:
REFUELING TEXT 3.9.4
Title:
REFUELING TEXT 3.9.5
Title:
REFUELING 0
11/15/2002 OPERATIONS CONTROL ROD POSITION:
0 11/15/2002:
OPERATIONS:CONTROL ROD POSITION.:INDICATION 0 :
11/15/2002 OPERATIONS CONTROL ROD OPERABILITY -
REFUELING Page7 of 8
Report Date: 12/08/05 Page 7 of 8 Report Date: 12/08/05
SSES MANUAL Manual Name: TSB1
'Manual
Title:
TECHNICAL SPECIFICATION BASES UNIT 1 MANUAL' TEXT 3.9.6 0
11/15/2002
Title:
REFUELING OPERATIONS REACTOR PRESSURE VESSEL (RPV) WATER"LEVEL TEXT 3.9.7 0
11/15/2002
Title:
REFUELING OPERATIONS RESIDUAL HEAT REMOVAL (RHR) -
HIGH WATER-LEVEL TEXT 3.9.8 0
11/15/2002
Title:
REFUELING OPERATIONS RESIDUAL HEAT REMOVAL (RHR) -
LOW WATER LEVEL U
TEXT3.10.1
Title:
SPECIAL TEXT 3.10.2
Title:
SPECIAL OPERATIONS OPERATIONS 0
11/15/2002 INSERVICE LEAK AND HYDROSTATIC:TESTING OPERATION 0
11/15/2002 REACTOR MODE SWITCH INTERLOCK TESTING ET 3.10.3
Title:
SPECIAL 0
11/15/2002 SINGLE CONTROL ROD WITHDRAWAL -
HOT SHUTDOWN -. I -. U OPERATIONS TEXT 3.10.4;
Title:
SPECIAL TEXT 3.10.5
Title:
SPECIAL TEXT 3.10.6
Title:
SPECIAL TEXT 3.10.7
Title:
SPECIAL OPERATIONS OPERATIONS OPERATIONS OPERATIONS 0
11/15/2002 SINGLE CONTROL ROD WITHDRAWAL -'COLD SHUTDOWN 0
11/15/2002 SINGLE CONTROL ROD DRIVE (CRD)
REMOVA.1,.-
REFUELING 0
11/15/2002 MULTIPLE CONTROL ROD WITHDRAWAL REFUELING 0
11/15/2002 CONTROL ROD TESTING - OPERATING TEXT 3.10.8
Title:
SPECIAL 0
11/15/2002 SHUTDOWN MARGIN (SDM)
TEST -
REFUELING
- -~~~
OPERATIONS Page8 of 8
Report Date: 12/08/05 Page 8
- of -8 Report Date:' 12/08/05
II I.i -'
Ii i -
. I I-I, I
SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL-SPECIFICATIONS BASES)
Section
.. ITOC T itle Table of Contents
-I Revision
_ 7 B 2.0 SAFETY LIMITS BASES Page B 2.0-1
-Page TS/B 2.0-2 Page TS/8 2.0-3 Pages TS/ B 2.0-4 and TS /B 2.0-5 Page TS/B 2 0-6 Pages B 2.0-7 through.B 2.0-9 I.0 I. 2 3
.I 2 0
B 3.0 LCO AND SR APPLICABILITY BASES Pages B 3.0-1 through B 3.0-4 Pages TS I ~B 3.0-5 through TS / B 3.0-7
/
Pages TS /8B3.0-8 through TS /B 3.0-9 Pages TS /83.0-1-0 through TS IB 3.0-12 Pages TS /83.0-1I3 through TS /83.0-1 5 Pages TS /83.0-16 and TS IB 3.0-17 B 3.1 REACTIVITY CONTROL BASES
/
Pages B 3.1-1 through B 3.1-5 Pages TS/B 3.1 6nd TSIB317\\
- Pages B 3.1-8 through B 3.1-13
- PageTS/B 3.1-14 Pages B 3.1-15 throughtb 3.1-2
- Page TS / B3.1-23 /F~
~
Pages B 3.1-24.throughKB 3.1~27 Page TS B 3. 1 ~28 Page TS/B.3.1 29 -
Pages B 3. 1 30 through B 3.1-33 PagesTS7 B 3.3-34 through TS /83.3-36 Page TSi 83.1-37 Page TUS/
p.1-38
- Pages B 3.1-39 through B 3.1-44 P~age B 3.1-46 and.-B 3.1-47 Pages'TS B 3.1-48 and TS B 3 1-49
-Page B 3.1 Page TS B 3.1-51 0
I 2
I
.2 0
0 I
0 0
I 0
.,.j.1.
I 0
I 2
0 I
I
.1 B 3.2' POWER DISTRIBUTION LIMITS BASES
- Page TS B 3.2-1
- Page TS/B 3.2-2 Page TS /B 3.2-3 Page TS B 3.2-4 Pages TS /B 3.2-5 and TS /B 3.2-6, Page 8 3.2-7 Pacies TS /B 3.2-8 throuqh TS /B 3.2-10 0
I I
2.
I 2
I 0
I
- I i
. I.
i..-
SUSQUEHANNA -UNIT.1 TS /B LOES1 Revision 67
1 SUSQUEHANNA STEAM ELECTRIC STATION UST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)
- Section Title
- I Page TS I B 3.2-11 Page B 3.2-12 Page TS I B 3.2-13 Pages B 3.2-14 and B 3.2-15' Page TSI B 3.2-16 Pages B 3.2-17 and B 3.2-18 Page TS I B 3.2-19 B 3.3 INSTRUMENTATION Pages.TS I B 3.3-1 through TS I B 3.3-4, Page TS I B 3.3-5 Page TS! B 3.3-6 Pages TS I B 3.3-7 through TS I B 3.3-11 Page TS B 3.3-12 Page TSl B 33-13 Page TS I B 3.3-14 Pages TS B 3.3-15 and TS B 3.3-16 Pages TS / B 3.3-17 and TS I B 3.3-18 Pages TS I B 3.3-19 through TS I B 3.3-27 Pages TS I B 3.3-28 through TS I B 3.3-31 Pages TS ! B 3.3-32 and TS I B.3.3-33 Pages TS I B 3.3-34 through TS I B 3.3-43 Pages TS / B 3.3-43a through TS / B 3.3-43i Pages TS I B 3.3-44 through TS IB 3.3-50 Pages TS I B 3.3-51 through TS I B 3.3-53 Page TS B 3.3-54 Pages B 3.3-55 through B 3.3-63.
Pages TS B 3.3-64 and TS B 3.3-65 Page TS I B 3.3-66 Page TS B 3.3-67 Page TS B 3.3-68 Pages TS I B 3.3-9 and TS / B 3.3-70 Page TS / B 3.3-71 Pages TS /3.3-72 through TS /3.3-75 Page TS B 3.3-75a Pages TS I B 3.3-75b and TS i B 3.3-75c Pages B 3.3-76 through 3.3-77' Page TS B 3.3-78 Pages B 3.3-79 through B 3.3-89 Page TS / B 3.3-90 Page B 3.3-91 Page TS / B 3.3-92 through TS I B 3.3-100:
Pages B 3.3-1 01 through B 3.3-103 Page TS/ B 3.3-104 Pages B 3.3-105 and B 3.3-106 PageTS/B3.3-107:
Page'B 3.3-108 t
-Revision
-2
.0
-2 2.-
3 2.
- 2 2
.2 1
2 1
2 4
2' 0
2
_4 4
3
'.3 4.
-4.
' 0
.0
-1 1'
0 SUQEAN UNI _.SBO-Reiin6
. SUSQUEHANNA - UNIT-1
-.-TS / B LOES-2
. Revision 67
SUSQUEHANNA STEAM ELECTRIC G TATION.
- LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)
Q Section litle Page TS / B 3.3-109-Pages B 3.3-110 and B 3.3-111 Pages TS / B 3.3-112 and TS / B 3.3-112a Pages TS /lB 3.3-113 and TS / B 3.3-114 PageTS/B3.3-115 Page TS B 3.3-116
'Page TS B 3.3-117, Pages B 3.3-118 through B 3.3-122 Pages TS I B 3.3-123 and TS I B 3.3-124 Page TS/ B 3.3-124a Page B 3.3-125 Page TS/B3.3-126 Page TS / B 3.3-127 Pages B 3.3-128 through B 3.3-130 Page TS I B 3.3-131 Pages B 3.3-132 through B 3.3-137 Page TS/B3.3-138 Pages B 3.3-139 through B 3.3-149 Page TS / B 3.3-150 through TS / B 3.3-162 Page TS/ B 3.3-163 Pages TS / B 3.3-164 through TS / B 3.3-177 Pages TS / B 3.3-178 and TS I B 3.3-179 Page TS / B 3.3-179a Page TS / B 3.3-179b Page TS / B 3.3-179c Page TS / B 3.3-180 PageTS/B3.3-181 Pages TS / B 3.3-182 through TS / B3.3-186 Pages TS / B 3.3-187 and TS B 3.3-188 Pages TS I B 3.3-189 through TS / B 3.3-191 Pages B 3.3-192 through B 3.3-204 Page TS / B 3.3-205 Pages B 3.3-206 through B 3.3-219 Revision' 1.
-2.
'I I:
0 0
1 0
- 1 2
1 2.
2
.00 2
2 10 10 3
2' 2
1I 0
1I O0 1
0O.
B3.4
- REACTOR COOLANT SYSTEM BASES Pages B 3.4-1 and B 3.4-2 Page TS / B 3.4-3 and Page TS / B 3.4-4'
-Pages TS I B 3.4-5 through TS / B 3.4-9 Pages B 3.4-10 through B 3.4-14 Page TS / B 3.4-15 Pages TS / B'3.4-16 and TS I B 3.4-17 Page TS / B 3.4-18' Pages B 3.4-19 through B 3.4-28 Page TS I B 3.4-29 Pages B 3.4-30 and B 3.4-31 Page TS / B 3.4-32 Pages B 3.4-33 through B 3.4-36 SUSQUEHANNA - UNIT 1 E
Revision 67
.TS / B LOES-3
SUSQUEHANNA STEAM ELECTRIC STATION LIST-OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES) -
- Section Title Page TS B 3.4-37 Pages B 3.4-38 through B 3.4-40 Page TS / B 3.4-41 Pages B 3.4-42 through B 3.4-48 PageTS/B3.4-49 Page TS/ B 3.4-50 Page TS/ B 3.4-51 Pages TS I B 3.4-52 and TS I B 3.4-53 Page TS J B 3.4-54 Page TS / B 3.4-55 Page TS / B 3.4-56 Page TS I B 3.4-57 Pages TS I B,3.4-58 through TS I B 3.4-60 B 3.5 ECCS AND RCIC BASES Pages B 3.5-1 and B 3.5-2 PageTS/B3.5-3 PageTS/B3.5-4 Page TS/B3.5-5 PageTS/B3.5-6 Pages B 3.5-7 through B 3.5-I0 Page TS / B 3.5-11
-'Pages B 3.5-12 through B 3.5-15 Pages TS / B 3.5-16 through TS / B 3.5-18 Pages B 3.5-19 through B 3.5-24 Page TS B 3.5-25 Pages TS I B 3.5-26 and TS I B 3.5-27 Pages B 3.5-28 through B 3.5-31 B 3.6 CONTAINMENT SYSTEMS BASES Page TS B 3.6-1 Page TS B 3.6-la Pages TS I B 3.6-2 through TS I B 3.6-5 PageTSIB3.6-6 Pages TS / B 3.66a and TS I B 3.6-6b Page TS /B 3.6-6c Pages B 3.6-7 through B 3.6-14 Page TS/B3.6-15 Pages TS I B 3.6-15a and TS I B 3.6-15b Page B 3.6-16 Page TS B 3.6 Page TS B 3.6-17a Pages TS / B 3.6-18 and TS /B3.6-19 Page TS/B3.6-20 Page TS I B 3.6-21 Page TS/B3.6-22 Page TS B 3.6-22a Revision 2
,-2 1*
2
-2
,. ' I 2
- 1 0
2 1.
-2
'01 0...
.2 0
30 2
30
.2 O
0O i
I
.1 SUSQUEHANNA-UNITI TSIB LOES-4 Revision 67 SUSQUEHANNA - UNIT 1 TS / B LOES-4
.. Revision 67
SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)
I.w)
I.
Ii I
I Section Title Page TS / B 3.6-23 Pages TS / B 3.6-24 through TS I B 3.6-25 Page TS / B 3.6-26 Page TS I B 3.6-27 Page TS I B 3.6-28 Page TS/ B 3.6-29 Page TS/ B 3.6-30 Page TS I B 3.6-31 Page B 3.6-32 Page TS/B3.6-33 Pages B 3.6-34 and B 3.6-35 Page TS I B 3.6-36 Page B 3.6-37 Page TS B 3.6-38, Page B 3.6-39 Page TS / B 3.6-40 Pages B 3.6-41 through B 3.6-43 Pages TS I B 3.6-44 and TS I B 3.6-45 PageTS/B3.6-46 Pages TS 1 B 3.6-47 through TS I B 3.6-51 Page TS I B 3.6-52 Pages B 3.6-53 through B 3.6-63 Page TS B 3.6-64 Pages B 3.6-65 through B 3.6-72 Page TS/ B 3.6-73 Pages B 3.6-74 through B 3.6-77 Page TS I B 3.6-78 Pages B 3.6-79 through B 3.3.6-83 Page TS i B 3.6-84 Page TS/ B 3.6-85 Page TS / B 3.6-86 PageTS/B3.6-87 Pages TS I B 3.6-88 and TS I B 3.6-88a Page TS / B 3.6-89 Page TS/ B 3.6-90 Page TS/ B 3.6-91 Pages TS I B 3.6-92 through TS I B 3.6-96 Page TS / B 3.6-97 Pages TS I B 3.6-98 and TS I B 3.6-99 Page TS / B 3.6-100 Pages TS I B 3.6-101 and TS I B 3.6-102; Pages TS I B 3.6-103 and TS I B 3.6-104 PageTS/B3.6-105 Pages TS I B 3.6-106 and TS I B 3.6-107 I
Revision 2
5.
, 1
'3 0O
..0 o
.3 1
2,
- 1 0
-0
'.3 23, 3
- 2 2
'1 2
- 3. 2 i md -
t,i..:
11..
IL_'_.I..,-
SUSQUEHANNA-UNIT 1
-TS I B LOES-5 Revision 67
SUSQUEHANNA STEAM ELECTRIC S1ATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)
Section Iitle B 3.7 PLANT SYSTEMS BASES Pages TS i B 3.7-1 through TS I B 3.7-6 Page TS I B 3.7-6a Pages TS / B 3 3.7-6b and TS B 3.7-6c Page TS /B 3.7-7 Pages TS./ B 3.7-8 through TS I B 3.7-11 Pages TS / B 3.7-12 and TS / B 3.7-13 Pages TS / B 3.7-14 through TS B 3.7-18 Page TS/ B 3.7-18a Pages TS / B 3.7-19 through TS I B 3.7-23 Pages B 3.7-24 through B 3.7-26 Pages TS / B 3.7-27 through TS / B 3.7-29 Page TS / B 3.7-30
-Pages B 3.7-31 through B 3.7-33 B 3.8 ELECTRICAL POWER SYSTEMS BASES Pages TS I B 3.8-1 through TS I B 3.8-4.
PageTS/B3.8-5 Page TS B 3.8-6 Pages TS /,B 3.8-7 throughTS/B 3.8-8 Page TS/B3.8-9 PageTS/1B3.8-10 Pages TS I B 3.8-11 and TS B 3.8-17 Page TS/ B 3.8-18 Pages TS I B 3.8-19 through TS I B 3.8-21
-Pages TS I B'3.8-22 and TS I B 3.8-23 Pages TS I B 3.8-24 through TS I B 3.8-37 Pages B 3.8-38 through B 3.8-53 Pages TS I B.3.8-54 through TS / B 3.8-1 Page TS /B3.8-62 Page TS / B 3.8-63 Page TS B 3.8-64 Page TS / B 3.8-65 Pages B 3.8-66 through B 3.8-80 Page TS lB 3.8-81 Pages B 3.8-82 through B 3.8-90 B 3.9 REFUELING OPERATIONS BASES Pages TS / B 3.9-1 and TS / B 3.9-1a Pages TS I B 3.9-2 through TS I B 3.9-4
- Pages B 3.9-5 through B 3.9-30 ti Revision
.2
' 2' 2
- 0 2
1, 1
2 O'
.1 0
4.
2-0-
I i
iI,w)
' 2 4.
-3,
'*2'
'4 3.
2 -
-3
.2
0 1
- *2 12
.0 10 I 1 I1 0
SUSQUEHANNA - UNIT 1 TS / B LOES-6 Revision 67 I.~~.
- .~~*
SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES) i,
i f Section litle B 3.10 SPECIAL OPERATIONS BASES Page TSIB3.10-1 Pages B 3.10-2 through B 3.10-31 Page TS B 3.10-32
-Pages B 3.10-33 through B 3.10-37 Page TS B 3.10-38 I
Revision I
0.
1*
1' TSB1 text LOES 11t21o05 I
I..
I i:f SUSQUEHANNA
- UNIT I TS/BLOES-7 Revision 67 ISUSQUEHANNA
-UNIT I. -
TS /B LOES-7.
Revision 67
PPL Rev. 3 PCIVs B 3.6.1.3 i1.
vd ii.
i-i Ii
iI '.
-B 3.6 CONTAINMENT SYSTEMS B 3.6.1.3 Primary Containment Isolation Valves (PCIVs)
BASES BACKGROUND i
The function of the PCIVs, in combination with other accident mitigation systems, is to limit fission product release during and following postulated Design Basis Accidents (DBAs) to within limits. Primary containment isolation within the time limits specified for those isolation valves designed to close automatically ensures that the release of radioactive material to the environment will be consistent with the assumptions used in the analyses for a DBA.
1W)
The OPERABILITY requirements for PCIVs help ensure that an adequate primary containment boundary is maintained during and after an accident by minimizing potential paths to the environment.
Therefore, the OPERABILITY requirements provide assurance that primary containment function assumed in the safety analyses will be maintained. For PCIVs; the primary containment isolation function is that the valve must be able to close (automatically or manually) and/or remain closed, and maintain leakage within that assumed in the DBA LOCA Dose Analysis. These isolation devices are either passive or active (automatic). Manual valves, de-activated automatic valves secured in their closed position (including check valves with flowithrugh the valve secured), blind flanges, and closed systems are considered passive devices. The OPERABILITY requirements for closed systems are discussed in Technical Requirements Manual (TRM) Bases 3.6.4. Check valves, or other automatic valves designed to close without operator action following an accident, are considered active devices. Two barriers in series are provided for each penetration so that no single credible failure or malfunction of an active.'
component can result in a loss of isolation or leakage that exceeds'limits assumed in the safety analyses. One of these barriers may be a closed system.
-For each division of H202 Analyzers, the lines, up to and including the first normally closed valves within the H202 Analyzer panels, are extensions of primary containment (i.e.,
closed system), and are required to be leak rate tested in' (continued) i.. '
I IfI I
I i (Viiii) i I-Ii.II I....
II L.
'SUSQUEHANNA - UNIT 1,.
TS / B 3.6-15 Revision 2
PPLRev.3 PCIVs B 3.6.1.3 BASES BACKGROUND (continued) accordance with the Leakage Rate Test Program. The 1202 Analyzer closed system boundary is identified in the Leakage Rate Test Program. The closed system boundary consists of those components, piping, tubing, fittings, and valves, which meet the guidance of Reference 6. -The closed system provides a secondary barrier in the event of a single failure of the PCIVs, as described below. The closed system boundary between PASS and the H202 Analyzer system ends at the process sampling solenoid operated isolation valves between the systems (SV-12361, SV-12365, SV-12366, SV-12368, and SV-12369). These solenoid operated isolation valves do not fully meet the guidance of Reference 6 for closed system boundary valves in that they are not powered from a Class 1 E power source. However, based upon a risk determination, operating these valves as closed system boundary valves is not risk significant. These valves also form the end of the Seismic Category I boundary between the systems. These process sampling solenoid operated isolation valves are normally closed and are required to be leak rate tested in accordance with the Leakage Rate Test Program as part of the closed system for the H202 Analyzer system. These valves are "closed system boundary valves" and may be opened under administrative control, as delineated in Technical Requirements Manual (TRM) Bases 3.6.4: Opening of these valves to permit testing of PASS in Modes 1,2, and 3 is permitted in accordance with TRO 3.6.4.
Each H202 Analyzer Sampling line penetrating primary containment has two PCIVs, located just outside primary containment While two PCIVs are provided on each line, a single active failure of a relay in the control circuitry for these valves, could result in both valves failing to close or failing to remain closed. Furthermore, a single failure (a hot short in the common raceway to all the valves) could simultaneously affect all of the PCIVs within a H202 Analyzer division. Therefore, the containment isolation barriers for these penetrations consist of two PCIVs and a closed system. For situations where one or both PCIVs are inoperable, the ACTIONS to be taken are similar to the ACTIONS for a single PCIV backed by a closed system.
i I -.
I.,
I :
II iI,
I I
(continued)
SUSQUEHANNA-UNIT I I
, TS / B 3.6-15a Revision 0 I
- I I
. I I.
I..
.. I. -
I.
... I t'-. _. _-__ I
PPL Rev. 3 PCIVs B 3.6.1.3 BASES BACKGROUND (continued)
The drywell vent and purge lines are 24 inches in diameter; the suppression chamber vent and purge lines are 18 inches in diameter. The containment purge valves are normally maintained closed in MODES 1, 2, and 3 to ensure the primary containment boundary is maintained. The outboard isolation valves have 2 inch bypass lines around them for use during normal reactor operation.
II:
!.6 I.
(continued)
SUSQUEHANNA - UNIT 1
- TS / B 3.6-15b Revision 0**
L
PPL Rev. 3.
PCI Vs B 3.6.1.3' BASES (continued)
APPLICABLE:
The PCIVs LCO was derived from the Assumptions related SAFETY ANALYSES to minimizing the loss of reactor coolant inventory, and establishing the primary containment boundary during major accidents. As part of the primary containment boundary, PCIV OPERABILITY supports leak tightness of primary containment Therefore, the safety analysis of any event requiring isolation of primary containment is applicable to this LCO.
The DBAs that result in a release of radioactive material within primary containment are a LOCA and a main steam line break (MSLB). In the analysis for each of these accidents, it is assumed that PCIVs are either closed or close within the required isolation times following event initiation. This ensures that potential paths to the environment through PCIVs (including primary containment purge valves) are minimized.' Of the events analyzed in Reference 1, the
-MSLB is the most limiting event due to radiological consequences.
The closure time of the main steam isolation valves (MSIVs) is a significant variable from a radiological standpoint. The MSIVs are required to close within 3 to 5 seconds since the 5 second closure time is assumed in the analysis. The safety analyses assume that the purge valves were closed at event initiation. Likewise, it is assumed that the primary containment is isolated such that release of fission products to the environment is controlled.
The DBA analysis assumes that within the required isolation time leakage is terminated, except for the maximum allowable leakage rate, La.
The single failure criterion required to be imposed in the conduct of unit safety analyses was considered in the original design of the primary containment purge valves. Two valves in series on each purge line provide assurance that both the supply and exhaust lines could be isolated even if a single failure occurred.
The primary containment purge'valves may be unable to close in the environment following a LOCA. Therefore, each of the purge valves is required to remain closed during MODES 1, 2, and 3 except as permitted under Note 2 of SR 3.6.1.3.1. In this case, the single failure criterion remains applicable to the primary containment purge valve-(continued)
SUSQUEHANNA-UNIT 1 B 3.6-16 Revision 0 1-
- I-I-.-
I~--
-- I.I I.
-. - I I-.- -
i.,
- B 3.6.1.3 BASES APPLICABLE SAFETY ANALYSES (continued) due to failure in the control circuit assodiated with each valve. The primary containment purge valve design precludes a single failure from compromising the primary-containment boundary as long as the system is operated in accordance with this LCO.
Both H202 Analyzer PCIVs may not be able to close given a single failure in the control circuitry of the valves. The single failure is caused by a "hot shortl in the cables/raceway to the PCIVs that causes both PCIVs for a given penetration to remain open or to open when required to be closed. This failure is required to be considered in accordance with IEEE-279 as discussed in FSAR Section 7.3.2a. However, the single failure criterion for containment isolation of the H202 Analyzer penetrations is satisfied by virtue of the combination of the associated PCIVs and the closed system formed by the H202 Analyzer piping system as discussed in the BACKGROUND section above.
The closed system boundary between PASS and the H202 Analyzer system ends at the process sampling solenoid operated isolation valves between the systems (SV-12361, SV-12365, SV-12366, SV-12368, and SV-12369). The closed system is not fully qualified to the guidance of Reference 6 in that the closed system boundary valves between the H202 system and PASS are not powered from a Class 1 E power source. However, based upon a risk determination, the use of these valves is considered to have
- no risk significance. This exemption to the requirement of Reference 6 for the closed system boundary, is documented in LicenseAmendment No. 195.
PCIVs satisfy Criterion 3 of the NRC Policy Statement. (Ref.2)
I 1%
I I
I i
I,
II I
i j,
i Iii 1 :
ii LCO PCIVs form a part of the, primary containment boundary. The PCIV safety function is related to minimizing the loss of reactor coolant inventory and establishing the primary containment boundary during a DBA.
I,
.I.
i I I j
i I
j I I
i I Md jji -
4 1 -
i
-. 1 -
II The power operated, automatic isolation valves are required to have isolation times within limits and actuate on an automatic isolation signal. The valves covered by this LCO are listed in Table B 3.6.1.3-1.
(continued)
SUSQUEHANNA - UNIT I Revision 1 TS / B 3.6-17 -, '
i L..., -
PPL Rev. 3 PCIVs B 3.6.1.3 I BASES
- . i(
i 40) 1 Ii -IIf LCO (continued)
The normally closed PCIVs are consideied OPERABLE when manual valves are closed or open in accordance with appropriate administrative controls, automatic valves are in their closed position, blind flanges are in place, and closed systems are intact. These passive isolation valves and devices are those listed in Table B 3.6.1.3-1.
Purge valves with resilient seals, secondary containment bypass valves, MSIVs, and hydrostatically tested valves must meet additional leakage rate requirements. Other PCIV leakage rates are addressed by LCO 3.6.1.1, "Primary Containment," as Type B or C testing.
This LCO provides assurance that the PCIVs will perform their designed safety functions to minimize the loss of reactor coolant inventory and establish the primary containment boundary during accidents.
APPLICABILITY In MODES 1, 2, and 3, a DBA could cause a release of radioactive material to primary containment. In MODES 4 and 5, the probability and consequences of these events are reduced due to the pressure and temperature limitations of these MODES.
Therefore, most PCIVs are not required to be I
!. 11 -
I
'(continued)
SUSQUEHANNA - UNIT 1 TS / B 3.6-17a Revision 0
PPL Rev. 3 PCIVs B 3.6.1.3 D A Q=Q
.Q APPLICABILITY OPERABLE and the primary containment purge valves are (continued) not required to be closed in MODES 4 and 5. Certain valves,
-however, are required to be OPERABLE to prevent inadvertent reactor vessel draindown. These valves are those whose associated instrumentation is required to be OPERABLE per LCO 3.3.6.1, "Primary Containment Isolation Instrumentation."
(This does not include the valves that isolate the associated instrumentation.)
ACTIONS The ACTIONS are modified by a Note allowing penetration flow path(s) to be unisolated intermittently under administrative controls. These controls consist of stationing a dedicated operator at the controls of the valve, who is in continuous communication with the control room. In this way, the penetration can be rapidly isolated when a need for primary containment isolation is indicated.
A second Note has been added to provide clarification that, for the purpose of this LCO, separate Condition entry is allowed for each penetration flow path. This is acceptable, since the Required Actions for each Condition provide appropriate compensatory actions for each inoperable PCIV. Complying with the Required Actions may allow for continued operation, and subsequent inoperable PCIVs are governed by subsequent Condition entry and application of associated Required Actions..
The ACTIONS are modified by Notes 3 and 4. Note 3 ensures that appropriate remedial actions are taken, if necessary, if the affected system(s) are rendered inoperable by an inoperable PCIV (e.g., an Emergency Core Cooling System subsystem is inoperable due to a failed open test return valve). Note 4 ensures appropriate remedial actions are taken when the primary containment leakage limits are exceeded. Pursuant to LCO 3.0.6, these actions are not required even when the associated LCO is not met. Therefore, Notes 3 and 4 are added to require the proper
-actions be taken.
A.1 and A.2 With one or more penetration flow paths with one PCIV inoperable except for purge valve leakage not within limit, (continued)'
Iii -.:
Ii, -
i : -
fII SUSQUEHANNA - UNIT I
. -B 3.6-18 Revision 0
PPL Rev. 3 IPCI Vs B 3.6.1.3
. (40
BASES.
I ACT101ITS A.1I and A.2 (continued) the affected penetration flow paths must be isolated. The method of
.isolation must include the use of at least one isolation barrier that cannot be adversely affected by a single active failure. Isolation barriers that meet this criterion are a closed and de-activated automatic valve, a closed manual valve, a blind flange, and a check valve with flow through the valve secured. For a penetration isolated in accordance with Required Action A.1, the device used to isolate the penetration should be the closest available valve to the primary containment. The Required Action must be completed within the 4 hour4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> Completion Time (8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> for main steam lines). The Completion Time of 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> is reasonable considening the time required to isolate the penetration and the relative importance of supporting primary containment OPERABILITY during MODES 1, 2, and 3. For main steamr lines, an 8 hour9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> Completion Time is allowed. The Completion Time of 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> for the main steam lines allows a period of time to restore the MVSIVs to OPERABLE status given the fact that MSIV closure will result in isolation of the main steam line(s) and a potential for plant shutdown.
For affected penetrations that have been isolated in accordance with Required Action A.1, the affected penetration flow path(s) must be verified to be isolated on a periodic basis. This is necessary to ensure that primary containment penetrations required to be isolated following an' accident, and no longer capable of being automatically isolated, will be in the isolation position should an event occur. This Requi red Acton does ndt require any testing or device manipulation. 'Ratfier, it involves verification that those devices outside containment and capable of potentially being mispositioned are in the correct position. The Completion Time of "once per 31 days for isolation devices outside primary containment" is appropriate because the devices are operated under administrative controls and the probability.of their misalignment is low. For the devices inside primary containment, the time period specified "prior to entering MODE 2 or 3 from MODE 4, if primary containment was de-inerted while in MODE 4, if not performed within the previous 92 days" is based on engineering judgment and is considered reasonable in view of the inaccessibility of the devices and other administrative controls ensuring that device misalignment is an unlikely possibility.
frnnfint unŽ'il Ii W),
SUSQUEHANNA - UNIT 1 B 3.6-19 Revision 0 L
!PPL Rev. 3 PCIVs B 3.6.1.3 BASES ACTIONS A.1 and A.2 (continued)
Condition A is modified by a Note indicating that this Condition is only applicable to those penetration flow paths with two PCIVs except for the H202 Analyzer penetrations.
For penetration flow paths with one PCIV, Condition C provides
'the appropriate Required Actions. For the H20 2 Analyzer Penetrations, Condition D provides the appropriate Required Actions.
Required Action A.2 is modified by a Note that applies to isolation devices located in high radiation areas, and allows them to be verified by use of administrative means. Allowing verification by.
administrative means is considered acceptable, since access to these areas is typically restricted. Therefore, the probability of '
"misalignment of these devices, once they have been verified to be in the proper position, is low.
B.1 With one or more penetration flow paths with two PCIVs inoperable except for purge valve leakage not within limit, either
- -the inoperable PCIVs must be restored to OPERABLE status or
- the affected-penetration flow path must be isolated within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />.
The method of isolation must include the use of at least one isolation barrier that cannot be a~dversely affected by a single active failure. Isolation barriers that meet this criterion are a closed and de-activated automatic valve, a closed manual valve, and a blind flange. The 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> Completion Time is consistent with the ACTIONS of LCO 3.6.1.1.
Condition B is modified by a Note indicating this Condition is only applicable to penetration flow paths with two PCIVs except for the H202 Analyzer penetrations.: For penetration flow paths with one PCIV, Condition C provides the appropriate Required Actions. For the H202 Analyzer Penetrations, Condition D provides the appropriate Required Actions.
C.1 and C.2 With one or more penetration flow paths with one PCIV inoperable, the inoperable valve must be restored to OPERABLE status or the affected penetration flow path I
'(continued)
SUSQUEHANNA - UNIT 1 TS / B 3.6.20 Revision 1
% I I
. I L
...,_-
__ _.. -_ _.
_1,.I r -
------ I - --
I - --
l
-PPL Rev. 3 PCIVs B 3.6.1.3 BASES ACTIONS C.1 and C.2 (continued) must be isolated. The method'of isolation must include the use of at least one isolation barrier that cannot be adversely affected by a single active failure. Isolation barriers that meet this criterion are
-a closed and de-activated automatic valve, a closed manual valve, and a blind flange. A check valve may not be used to isolate the affected penetration. Required Action C.1 must be completed within the 72 hour8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> Completion Time. The Completion Time of 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> is reasonable considering the relative stability of the closed system (hence, reliability) to act as a penetration isolation boundary and the relative importance of supporting primary containment OPERABILITY during MODES 1, 2, and 3. The closed system must meet the requirements of Reference 6. For conditions where the PCIV and the closed system are inoperable,
'the Required Actions of TRO 3.6.4, Condition B apply. For the Excess Flow Check Valves (EFCV), the Completion Time of 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> is reasonable considering the instrument and the small pipe diameter of penetration (hence, reliability) to act as a penetration isolation boundary and the small pipe diameter of the affected penetrations. In the event the affected penetration flow path is isolated in accordance with Required Action C.1, the affected penetration must be verified to be isolated on a periodic basis. This is necessary to ensure that primary containment penetrations'required to be isolated following an accident are isolated. The Completion Time of once per 31 daysfor verifying each affected penetration is isolated is appropriate because the valves are operated under administrative controls and the probability of their'misalignment is low.
Condition C is modified by a Note indicating that this Condition is
' -only applicable to penetration flow pathsjwith only one PCIV. 'For penetration flow paths with two PCIVs and the H202 Analyzer Penetration. Conditions A, B and D provide the appropriate Required Actions.
Required Action C.2 is modified by a Note that applies to valves and blind flanges located in high radiation areas and allows them to be verified by use of administrative means. Allowing verification by administrative means is considered acceptable, since access to these areas is typically restricted. Therefore, the probability of misalignment of these valves, once they have been verified to be in the proper position, is low.
(continued)
SUSQUEHANNA - UNIT 1 TS i B 3.6-21 Revision 2 I,.
I:- -
, _.
I _-.-
_-_
I_
_
_. -
- '- -
I - -
_.., , _ _ 1, -.-
.
__.__: ___
PPL Rev. 3 PCIVs B 3.6.1.3 BASES ACTIONS D.1 and D.2 (continued)
Condition D is modified by a Note indicating that this Condition is only applicable to the H202 Analyzer penetrations.
E. 1 With the secondary containment bypass leakage rate not within limit, the assumptions of the safety analysis may not be met.
Therefore, the leakage must be restored to within limit within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />. Restoration can be accomplished by isolating the penetration that caused the limit to be exceeded by use of one closed and de-activated automatic valve, closed manual valve, or blind flange. When a penetration is isolated, the leakage rate for the isolated penetration is assumed to be the actual pathway leakage through the isolation device. If two isolation devices are used to isolate the penetration, the leakage rate is assumed to be the lesser actual pathway leakage of the two devices. The 4 hour4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> Completion Time is reasonable considering the time required to restore the leakage by isolating the penetration and the relative importance of secondary containment bypass leakage to the overall containment function.
F.1 In the event one or more containment purge valves are not within the purge valve leakage limits, purge valve leakage must be restored to within limits. The 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> Completion Time is reasonable, considering that one containment purge valve remains closed, except as controlled by SR 3.6.1.3.1 so that a gross breach of containment does not exist.
G.1 and G.2 If any Required Action and associated Completion Time cannot be met in MODE 1, 2, or 3, the plant must be brought to a MODE in which the LCO does not apply. To achieve this status, the plant must be brought to at least MODE 3 within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> and to MODE 4 within 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br />. The allowed Completion Times are reasonable, based on operating experience, to reach the required plant conditions from full power conditions in an orderly manner and without challenging plant systems.
(continued)
SUSQUEHANNA - UNIT 1 TS / B 3.6-22a Revision 0
PPL Rev. 3
- PCIVs B 3.6.1.3 BASES ACTIONS D.1 and D.2 (continued)
Condition D is modified by a Note indicating that this Condition is only applicable to the H202 Analyzer penetrations.
-E.1 With the secondary containment bypass leakage rate not within limit, the assumptions of the safety analysis may not be met.
- Therefore, the leakage must be restored to within limit within
.4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />.' Restoration can be accomplished by isolating the penetration that caused the limit to be exceeded by use of one closed and de-activated automatic valve, closed manual valve, or blind flange. When a penetration is isolated, the leakage rate for the isolated penetration is assumed to be the actual pathway'
'leakage through the isolation device. If two isolation devices are used to isolate the penetration, the leakage rate is assumed to be the lesser actual pathway leakage of the two devices. The 4 hour4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> Completion Time is reasonable considering the time required to restore the leakage by isolating the penetration'and the relative
- importance of secondary containment bypass leakage to the' overall containment function.
F.1 In the event one or more containment purge valves are not within
- the purge valve leakage'limits, purge valve leakage must be restored to within limits. The 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> Completion Time is reasonable, considering that one containment purge valve remains closed, except as controlled by SR 3.6.1.3.1 so that a gross breach of containment does not exist G. andG.2 If any Required Action and associated Completion Time cannot be met in MODE 1, 2, or 3, the plant must be brought to a MODE in which the LCO does not apply. To achieve this status, the plant must be brought to at least MODE 3 within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> and to MODE 4 within 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br />. The allowed Completion Times are reasonable, based on operating experience, to reach the required plant conditions from full power conditions in an orderly manner and without challenging plant systems.
(continued.
I.SUSQUEHANNA TS B 3.6 Revision 0
i I-v PPL Rev. 3 PCIVs B 3.6.1.3 i,, @
I I'
l:
I BASES ACTIONS
> (continued)
H.1 and H.2 If any Required Action and associated Completion Time cannot be met, the unit must be placed in a condition in' which the LCO does, not apply. If applicable, action must be immediately initiated to suspend operations with a potential for'draining the reactor vessel (OPDRVs) to minimize the probability of a vessel draindown and subsequent potential for fission product release. Actions must continue until OPDRVs are suspended or valve(s) are restored to OPERABLE status. If suspending an OPDRV would result in closing the residual heat removal (RHR) shutdown cooling isolation valves, an alternative Required Action is provided to immediately initiate action to restore the valve(s) to OPERABLE status. This allows RHR to remain in service while actions are being taken to restore the valve.,
SURVEILLANCE IREQUIREMENTS I
- i.
1
)
I.
SR 3.6.1.3.1 This SR ensures that the primary containment purge valves are closed as required or, if open, open for an allowable reason. If a purge valve is open in violation of this SR, the valve is considered inoperable. If the inoperable valve is not otherwise known to have excessive leakage when closed, it is not considered to have leakage outside of limits. The SR is also modified by Note 1, stating that primary containment purge valves are only required to
- '. be closed in MODES 1, 2, and 3..If a LOCA inside primary containment occurs in these MODES, the purge valves may not be capable of closing before the pressure pulse affects systems downstream of the purge valves, or the release of radioactive material will exceed limits prior to the purge valves closing. At other times when the purge valves are required to be capable of closing (e.g., during handling of irradiated fuel), pressurization concerns are not present and the purge valves are allowed to be open. The SR is modified by Note 2 stating that the SR is not required to be met when the purge valves are open for the stated reasons. The Note states that these valves may be opened for inerting, de-inerting, pressure control, ALARA or air quality considerations for personnel entry, or Surveillances that require the valves to be open. The vent and purge valves are capable of closing in the environment following a LOCA. Therefore, these valves are allowed to be open for, I
iI,.
I:!,
- (continued)
SUSQUEHANNA - UNIT 1 TS / B3.6-23
.Revision 1
- SR 3.6.1.3.1 (continued) limited periods of time. The 31 day Frequency is consistent with other PCIV requirements discussed in SR 3.6.1.3.2.
SR 3.6.1.3.2 This SR verifies that each primary containment isolation manual
-valve and blind flange that is located outside primary containment and not locked, sealed, or otherwise secured and is required to be closed during accident conditions is closed. The SR helps to ensure that post accident leakage of radioactive fluids or gases outside the primary containment boundary is within' design limits.
This SR does not require any testing or valve manipulation.,'
Rather,' it involves verification that those PCIVs outside primary containment, and capable of being mispositioned, are in the correct position. Since verification of valve position for PCIVs outside primary containment is relatively easy, the 31 day Frequency was chosen to provide added assurance that the PCIVs are in the correct positions.
Two Notes have been added to this SR. The first Note allows valves and blind flanges located in high radiation areas to be verified by use of administrative controls.' Allowing verification by administrative controls is considered acceptable since access to these areas is typically restricted during MODES 1,2, and 3 for
'ALARA reasons. Therefore, the probability of misalignment of' these PCIVs, once they have been verified to be in the proper position, is low. A second Note has been included to clarify that PCIVs that are open under administrative'controls are not required to meet the SR during the time that the PCIVs are open. This SR does not apply to valves that are locked, sealed, or otherwise secured in the closed position, since these were verified to be in the correct position upon locking, sealing, or securing.
SR 3.6.1.3.3 This SR verifies that each primary containment manual isolation valve and blind flange that is located inside primary containment and not locked, sealed, or otherwise -
(continued)
-SUSQUEHANNA - UNIT 1 B 3.6-24 Revision 0 I :
L_.--
i - -
L II - - - -
. -1. - I _
I I...
I- - I -
-Ir..
PPL Rev. 3 PCIVs B 3.6.1.3 BASES
.SURVEILLANCE REQUIREMENT' SR 3.6.1.3.3 (continued)
I secured and is required to be closed during accident conditions is closed. The SR helps to ensure that post accident leakage of radioactive fluids or gases outside the primary containment boundary is within design limits. ForPCIVs inside primary containment, the Frequency defined as- "prior to entering MODE 2 or 3 from MODE 4 if primary containment was de-inerted while in MODE 4, if not performed within the previous 92 days" is appropriate since these PCIVs are operated under administrative controls and the probability of their misalignment is low. This SR does not apply to valves that are locked, sealed, or otherwise secured in the closed position, since these were Verified to be in the correct position upon locking, sealing, or securing. Two Notes have been added to this SR. The first Note allows valves and blind flanges located in high radiation areas to be verified by use of administrative controls. Allowing verification by administrative controls is considered acceptable since the primary containment is inerted and access to these areas is typically restricted during MODES 1, 2, and 3 for ALARA reasons. Therefore, the probability of misalignment of these PCIVs, once they have been verified to be.in their proper position, is low. A second Note has been included to clarify that PCIVs that are open under administrative controls are not required to meet the SR during the time that the PCIVs are open.
SR 3.6.1.3.4 The traversing incore probe (TIP) shear isolation valves are actuated by explosive charges. Surveillance of explosive charge continuity provides assurance that TIP valves will actuate when required. Other administrative controls, such as those that limit
- the shelf life of the explosive charges, must be followed. The 31 day Frequency is based on operating experience that has demonstrated the reliability of the explosive charge continuity.
lo i
t t
I i. -,.
i,
I I
Ii i -.
I SR 3.6.1.3.5 Verifying the isolation time of each power operated and each automatic PCIV is within limits is required to demonstrate OPERABILITY. MSIVs may be excluded from this SR since MSIV (continued)
SUSQUEHANNA-UNIT BB 3.6-25 Revision 0.- -
PPL Rev. 3
' PCIVs
'B 3.6.1.3 i
I
-(WM) i i.
I i
i,
iI BASES SURVEILLANCE:
REQUIREMENTS SR 3.6.1.3.5 (continued) full closure isolation time is demonstrated by SR 3.6.1.3.7. The isolation time test ensures that the valve will isolate in a time period less than or equal to that assumed in the Final Safety Analyses Report. The isolation time and Frequency of this SR are in accordance with the requirements of the Inservice Testing Program.
For primary containment purge valves with resilient seals, the Appendix J Leakage Rate Test Interval of 24 months is sufficient.
The acceptance criteria for these valves is defined in the Primary Containment Leakage Rate Testing Program, 5.5.12.
The SR is modified by a Note stating that the primary containment purge valves are only required to meet leakage rate testing' requirements in MODES 1, 2, and 3. If a LOCA inside primary containment occurs in these MODES, purge valve leakage must be minimized to ensure offsite radiological release is within limits.
At other times when the purge valves are required to be capable of closing (e.g., during handling of irradiated fuel), pressurization concerns are not present and the purge valves are not required to meet any specific leakage criteria.
Verifying that the isolation time of each MSIV is within the specified limits is required to demonstrate OPERABILITY. The isolation time test ensures that the MSIV will isolate in a time period that does not exceed the times assumed in the DBA analyses. This ensures that the calculated radiological consequences of these events remain within 10 CFR 100 limits. The Frequency of this SR is in accordance with the requirements of the Inservice Testing Program.
(continued)
I, I ii i
,,ITT I
i I' `.
SUSQUEHANNA-UNIT 1 TS / B 3.6-26
- Revision I I
PPL Rev. 3 PCIVs B 3.6.1.3 BASES SURVEILJ REQUIREIV (continued kNCE
-11,To SR 3.6.1.3.8 1.
IItNIs i)
Automatic PCIVs close on a primary containment isolation signal to prevent leakage of radioactive material from'primary containment following a DBA. This SR ensures that each automatic PCIV will actuate to its isolation position on a primary containment isolation signal. The LOGIC SYSTEM FUNCTIONAL TEST in SR 3.3.6.1.5 overlaps this SR to provide complete testing of the safety function. The 24 month'Frequency was developed considering it is prudent that some of these Surveillances be performed only during a unit outage since isolation of penetrations could eliminate cooling water flow and disrupt the normal operation of some critical components. Operating experience has shown that these components usually pass this Surveillance when performed at the 24 month Frequency. Therefore, the Frequency was concluded to be acceptable from a reliability standpoint.
SR 3.6.1.3.9 This SR requires a demonstration that a representative sample of reactor instrumentation line excess flow check valves (EFCV) are OPERABLE by verifying that the valve actuates to check flow on a simulated instrument line break. As defined in FSAR Section 6.2.4.3.5 (Reference 4), the conditions under which an EFCV will isolate, simulated instrument line' break, are at flow rates which develop a differential pressure of between 3 psid and 10 psid.
This SR provides assurance that the instrumentation line EFCVs will perform its design function to check flow. No specific valve leakage limits are specified because no specific leakage limits are defined in the FSAR. The'24 month Frequency is based on the need to perform some of these Surveillances under the conditions that apply during a plant outage and the potential for an unplanned transient if the Surveillance were performed with the
-reactor at power. The representative sample consists of an approximate equal number of EFCVs such that each EFCV is tested at least once every 10 years (nominal). The nominal 10 year interval is based on other performance-based testing programs, such as Inservice Testing (snubbers) and Option B to 10 CFR 50, Appendix J. In addition, the EFCVs in the sample are representative of the various plant configurations, models, sizes and operating environments. This ensures that any potential common problems with a specific type or application of EFCV is detected at the earliest possible time. EFCV failures will be evaluated to determine if additional testing in that test interval is warranted.to ensure overall reliability and that failures to isolate are very infrequent. Therefore, testing of a representative sample
- was concluded to be acceptable from a reliability standpoint (Reference 7).
(continued) j Ii Ir
Wd i -Ai 11 Ii -
I -It-,-
SUSQUEHANNA - UNIT i TS /B 3.6-27
.Revision 2
PPL Rev. 3 PCI Vs
- B 3.6.1.3 BASES SURVEILLANCE SR 3.6.1.3.10 REQUIREMENTS (continued)
The TIP shear isolation valves are actuated by explosive charges. An in place functional test is not possible with this design. The explosive squib is removed and tested to provide assurance that the valves will actuate when required. The replacement charge for the explosive squib shall be from the same manufactured batch as the one-fired or from another batch that has been certified by having one of the batch successfully fired. The Frequency of 24 months on a STAGGERED TEST BASIS is considered adequate given the administrative controls on replacement charges and the frequent checks of circuit continuity (SR 3.6.1.3.4).
SR 3.6.1.3.11 This SR ensures that the leakage rate of secondary containment bypass leakage paths is less than the specified leakage rate. This provides assurance that the assumptions in the radiological evaluations of Reference 4 are met The secondary containment leakage pathways and Frequency are defined by the Primary. Containment Leakage Rate
-Testing Program. This SR simply imposes additional acceptance criteria.
A note is added to this SR which states that these valves are only required to meet this leakage limit in MODES 1, 2, and 3. In the other MODES, the Reactor Coolant System is not pressurized and specific primary containment leakage limits are not required.
SR 3.6.1.3.12 The analyses in References I and 4 are based on the specified leakage.l rate. Leakage through each MSIV must be
- 100 scfh for any one MSIV or
- 300 scfh for total leakage through the MSIVs combined with the Main Steam Line Drain Isolation Valve, HPCI Steam Supply Isolation Valve and the RCIC Steam Supply Isolation Valve. The MSIVs can be tested at either > Pt (22.5 psig) or P. (45 psig). Main Steam Line Drain Isolation, HPCI and RCIC Steam Supply Line Isolation Valves, are tested at Pa (45 psig). A note is added to this SR which states that these valves are only required to meet this leakage limit in MODES 1, 2, and 3. In the other conditions, the Reactor Coolant System is not pressurized and specific primary containment leakage limits are not required. The Frequency is required by the Primary Containment Leakage Rate Testing Program. If leakage from the MSIVs requires internal work on any MSIV, the leakage will be reduced for the affected MSIV to < 11.5 scfh.
(continued)
I a
,(Iran -
SUSQUEHANNA - UNIT 1 TS I B 3.6-28
Revision 5 t.:
PPL Rev. 3
' PCIVs B 3.6.1.3 I
BASES SURVEILLANCE REQUIREMENT!
(continued) -
SR 3.6.1.3.13 Surveillance of hydrostatically tested lines provides assurance that the calculation assumptions of Reference 2 are met. The
.'acceptance criteria for the combined leakage of all hydrostatically tested lines is 3.3 gpm when tested at 1.1 Pa, (49.5 psig). The combined leakage rates must be demonstrated in accordance with the leakage rate test Frequency required by the Primary Containment Leakage Testing Program.
As noted in Table B 3.6.1.3-1, PCIVs associated with this SR are not Type C tested. Containment bypass leakage is prevented since the line terminates below the minimum water level in the Suppression Chamber.' These valves are tested in accordance with the IST Program. Therefore, these valves leakage is not included as containment leakage.
This SR has been modified by a Note that states that these valves are only required to meet the combined leakage rate in MODES 1,
-2, and 3, since this is when the Reactor Coolant System is pressurized and primary containment is required. In some instances, the valves are required to be capable of automatically closing during MODES other than MODES 1, 2, and 3. However, specific leakage limits are not applicable in these other MODES or conditions.
-. 'REFERENCES
- 1.
FSAR, Chapter 15.
- 2.
' Final Policy Statement on Technical Specifications Improvements, July 22,1993 (58 FR 39132).
-3.
10 CFR 50, Appendix J, Option B.
'4.
-FSAR, Section 6.2.
-: 5.
-NEDO-30851-P-A, 'Technical Specification Improvement Analyses for BWR Reactor Protection System,"
March 1988.
6.'
Standard Review Plan 6.2.4, Rev. 1, September 1975
- 7.
NEDO-32977-A, -Excess Flow Check Valve Testing Relaxation," June 2000.
,1, I
.. v 1
. SUSQUEHANNA - UNIT 1 TS/B3.6-29 Revision 1 h-...-
.-.
.
-PPL Rev. 3 PCIVs
- B 3.6.1.3
W) :
Table B 3.6.1.3-1 Primary Containment Isolation Valve (Page I of 11)
Isolation Signal Valv Numer I
f~lv LCO 3.3.6.1 Function No.
'Plant System Valve Number Valve Description Type of Valve.L03361Fnto o
Tp Time (Seconds))
Plan Syte Vav Decito
.a
.&aiu isolatio
.ontainmernt Ottmospheric
- ontrol 1-57-193 (d)
ILRT Manual N/A 1-57-194 (d)
ILRT Manual N/A HV-15703 Containment Purge Automatic Valve 2.b. 2.d, 2.e (15)
HV-15704 Containment Purge Automatic Valve 2.b, 2.d. 2.e (15)
HV-15705 Containment Purge Automatic Valve 2.b, 2.d, 2.e (15)
HV-1 5711 Containment Purge Automatic Valve 2.b, 2.d, 2.e (15)
HV-15713 Containment Purge Automatic Valve 2.b, 2.d, 2.e (15)
HV-15714 Containment Purge Automatic Valve' 2.b, 2.d, 2.e (15)
HV-15721 Containment Purge Automatic Valve 2.b. 2.d, 2.e (15)
HV-15722 Containment Purge Automatic Valve 2.b. 2.d, 2.e (15)
HV-15723 Containment Purge Automatic Valve 2.b, 2.d, 2.e (15)
HV-1 5724 Containment Purge Automatic Valve 2.b. 2.d. 2.e (15)
HV-15725 Containment Purge Automatic Valve 2.b Zd. 2.e (15)
HV-1 5766 (a)
Suppression Pool Cleanup Automatic Valve 2.b. 2.d (30)
HV-15768 (a)
Suppression Pool Cleanup Automatic Valve Zb, 2.d (30)
SV-1 57100 A Containment Radiation Detection Automatic Valve' 2.b, 2.d Syst SV-157100 B Containment Radiation Detection Automatic Valve 2.b, 2.d Syst SV-1 57101 A Containment Radiation Detection Automatic Valve 2.b, 2.d Syst SV-157101 B Containment Radiation Detection Automatic Valve 2.b, 2.d
__________Syst.
SV-1 57102 A Containment Radiation Detection Automatic Valve 2.b, 2.d Syst SV-157102 B Containment Radiation Detection Automatic Valve 2.b, 2.d Syst SV-157103 A Containment Radiation Detection Automatic Valve 2.b. 2.d Syst SV-1 57103 B Containment Radiation Detection Automatic Valve 2.b,'2.d
' Syst SV-157104 Containment Radiation Detection Automatic Valve 2b. 2.d Syst SV-157105 Containment Radiation Detection Automatic Valve 2.b, 2d Syst SV-157106 Containment Radiation Detection Automatic Valve
'2b, 2d Syst SV-157107-Containment Radiation Detection Automatic Valve 2b, 2.d Syst SV-15734 A (e)
Containment Atmosphere Sample Automatic Valve
2.b. 2.d SV-1 5734 B (e) -
Containment Atmosphere Sample
=Automatic Valve 2.b, 2.d SV-15736 A (e)
Containment Atmosphere Sample Automatic Valve 2.b. Zd II ISV-15736 B (e)
Containment Atmosphere Sample Automatic Valve 2.b. 2 d 1SV-15737 Nitrogen Makeup:
AutomaticValve I Zb. 2.d, 2e SUSQUEHANNA-UNIT 1 TS / B3.6. Revision'!
A-'...-l-
'.. -- I.- --. 1 - --.-. -, -. -
-- I.-...
PPL Rev. 3 PCIVs B 3.6.1.3 Table B 3.6.1.3-1 Primary Containment Isolati6ri Valve (Page 2 of 11)
Isolation Signal LCO 3.3.6.1 Function No.
Plant System Valve Number Valve Description Type of Valve LC0 Isolation
.r Time (Seconds))
Containment SV-15738 Nitrogen Makeup Automatic Valve 2.b. 2.d, 2.e tmospheric SV-15740 A (e)
Containment Atmosphere Sample Automiatic Valve 2.b, 2.d Control SV-15740 B (e)
Containment Atmosphere Sample Automatic Valve 2.b. 2d (cont SVntainment Amosphere Sample Automatic Valve 2.b, 2.d SV-15742 B (e)
Containment Atmosphere Sample Automatic Valve 2.b, 2.d SV-1 5750 A (e)
Containment Atmosphere Sample Automatic Valve 2.b,2.d SV-15750 B (e)
Containment Atmosphere Sample Automatic Valve 2.b, 2.d SV-15752 A (e)
Containment Atmosphere Sample Automatic Valve 2.b. 2.d SV-15752 B (e)
Containment Atmosphere Sample Automatic Valve 2.b, 2d SV-15767 Nitrogen Makeup Automatic Valve 2.b, 2.d, 2.e SV-15774 A (e)
Containment Atmosphere Sample Automatic Valve 2.b, 2.d SV-15774 B (e)
Containment Atmosphere Sample Automatic Valve 2.b, 2.d SV-1 5776 A (e)
Containment Atmosphere Sample Automatic Valve 2.b, 2.d SV-15776 B (e)
Containment Atmosphere Sample Automatic Valve 2.b, 2.d SV-15780 A (e)
Containment Atmosphere Sample Automatic Valve 2.b, 2.d SV-15780 B (e)
Containment Atmosphere Sample Automatic Valve 2.b, 2.d SV-15782 A (e)
Containment Atmosphere Sample Automatic Valve 2.b, 2.d SV-1 5782 B (e)
ContainmentAtmosphere Sample Automatic Valve 2.b, 2d SV-15789 Nitrogen Makeup Automatic Valve 2.b. 2.d 2.e Containment 1-26-072 (d)
Containment Instrument Gas Manual Check' N/A Instrument Gas 1-26-074 (d)
Containment Instrument Gas
-Manual Check N/A 1-26-152 (d)
Containment Instrument Gas Manual Check N/A 1-26-154 (d).
Containment Instrument Gas ManualCheck N/A 1-26-164 (d)
Containment Instrument Gas Manual Check N/A HV-12603 Containment Instrument Gas Automatic Valve 2.c. 2.d (20)
SV-12605 Containment Instrument Gas Automatic Valve 2c. 2.d SV-12651 Containment Instrument Gas Automatic Valve 2c, 2.d SV-1 2654 A Containment Instrument Gas Power Operated N/A SV-12654 B Containment Instrument Gas Power Operated N/A SV-12661 Containment Instrument Gas Automatic Valve 2b, 2.d SV-1 2671 Containment Instrument Gas Automatic Valve 2b, 2.d Core Spray-HV-152F001 A (b)(c)
CS Suction Valve Power Operated N/A HV-152F001 B (b)(c)
CS Suction Valve Power Operated N/A HV-152F005 A CS Injection Power Operated N/A HV-152F005 B CS Injecton Valve Power Operated N/A HV-152F006 A CS Injection Valve Air Operated Check N/A
_ _ _V alve HV-1 52F006 B CS Injection Valve Air Operated Check N/A
-Valve
-152F01 5 A (b)(c)
S Test Valve Automatic Valve
.c, 2.d (80)
HV-152F015 B (b)(c)
CS Test Valve Automatic Valve 2c, 2.d (80)
SUSQUEHANNA - UNIT I R
I TS / B 3.6-31 IIRevisionS.,
-PPL Rev. 3 PCIVs B 3.6.1.3 0
Table B 3.6.1.3-1 (continued)
Primary Containment Isolation Valve (Page 3 of 11)
Isolation Signal LCO 3.3.6.1 Function No.
Plant System Valve Number Valve Description Type of Valve (Uaximum Isolation
'____T -
lime (Seconds))
Core Spray HV-1 52F031 A (b)(c)
CS Minimum Recirculation Flow Power Operated N/A (continued)
HV-152F031 B (b)(c) CS Minimum Recirculation Flow.
Power Operated N/A HV-152F037 A CS Injection Power Operated N/A (Air)
HV-152F037 B CS Injection Power Operated N/A (Air)
XV-152F018 A Core Spray Excess Flow Check N/A Valve XV-152F018 B Core Spray, Excess Flow Check N/A alve HPCI 1-55-038 (d)
HPCI Injection Valve Manual N/A 155F046 (b)(c)(d)
HPCI Minimum Flow Check Valve Manual Check N/A 155F049 (a)(d)
HPCI Turbine Exhaust Valve Manual Check N/A HV-155F002 HPCI Steam Supply Valve Automatic Valve 3.a, 3.b, 3.c, 3.e, 3.f,
_.-_'_3.g (50)
HV-155F003 HPCI Steam Supply Valve Automatic Valve 3.a, 3.b, 3.c, 3.e, 3.f,
._3.g (50)
HV-155F006 HPCI Injection Valve Power Operated N/A HV-155F01 2 (b)(c)
HPCI Minimum Flow Valve Power Operated N/A HV-155F042 (b)(c)
HPCI Suction Valve omatic Valve 3.a, 3.b, 3.c, 3.e, 3.f, 3.g (90)
HV-155F066 (a)
HPCI Turbine Exhaust Valve Power Operated N/A HV-155F075.
HPCI Vacuum Breaker Isolation utomatic Valve-3.b, 3.d (15) alve HV-155F079 HPCI Vacuum Breaker Isolation Automatic Valve 3.b, 3.d (15)
-Valve HV-155F100 HPCI Steam SupplyValve Automatic Valve 3.a, 3.b, 3.c, 3.e, 3.,
3.g (6)
XV-1 55F024 A HPCI Valve Excess Flow Check N/A Valve XV-155F024 B HPCI Valve Excess Flow Check N/A
_Valve XV-155F024 C' HPCI Valve Excess Flow Check N/A Valve XV-155F024 D HPCI Valve Excess Flow Check N/A.
Valve Liquid Radwaste HV-161 08 Al Liquid Radwaste Isolation Valve omatic Valve 2.b. 2.d (15)
Collection HV-161 08 A2 Liquid Radwaste Isolation Valve.
omatic Valve 2.b, 2.d (15)
HV-1 6116 Al Liquid Radwaste Isolation Valve omatic Valve 2b, 2.d (15)
HV-16116 A2 -
Liquid Radwaste Isolation Valve Automatic Valve 2.b. 2.d (15)
Demin Water 1-41-017 (d)
Demineralized Water Manual -
N/A 1-41-018 (d)
Demineralized Water Manual N/A Nuclear Boiler 141 F010 A (d)
Feedwater Isolation Valve Manual Check N/A 141 F010 B (d)
Feedwater Isolation Valve Manual Check N/A i
1 :
i.
I I
i i.'
i i
1111111
I I
I -
I r --
SUSQUEHANNA-UNIT:1 B 3.6-32
- Revision 0 L.
l l fi I:rj l
iD:
i::
l l
i
§: f l
1 l
l ll I
i I
V
'I I
f.
I I
i ::..
t :fi-I' L
PPL Rev. 3 PCIVs B 3.6.1.3 Table B 3.6.1.3-1 (continued)
Primary Containment Isolation Valve (Page 4 of 11)
Isolation Signal LCO 3.3.6.1 Function No.
Plant System Valve Number Valve Description Type of Valve -
Lsolation Time (Seconds))
Nuclear Boiler 141 F039 A (d)
Feedwater Isolation Valve Manual Check N/A (continued) 141 F039 B (d)
Feedwater Isolation Valve Manual Check N/A 141818 A (d)
Feedwater Isolation Valve Manual Check N/A 141818 B (d)
F eedwater Isolation Valve Manual Check N/A HV-141F016 MSL Drain Isolation Valve Automatic Valve 1.a, 1.b,1.c, 1.d, I.e
_ _ _(10
)
HV-141F019 MSL Drain Isolation Valve AutomaticValve.
1.a, 1.b, 1.c, 1.d, I.e (15)
HV-141 F022 A MSIV Automatic Valve.
1.a, 1.b,1.c, 1.d, 1.e HV-141F022 B MSIV Automatic Valve 1.a, 1.b, 1.c, 1.d. I.e
_(5)
HV-141 F022 C MSIV Automatic Valve 1.a, 1.b, 1c, 1.d,1.e
.(
5 )
HV-141F022 D MSIV Automatic Valve 1.a, 1.b, 1.c, 1.d, I.e
( 5 )
HV-141 F028 A MSIV utomatic Valve
-1 a, 1.b, 1.c,I.d, 1.e
>(5)
HV-141F028 B MSIV Automatic Valve a,1.b, 1.c, 1.d, 1.e
- (5)
HV-141F028C MSIV Automatic Valve.
1.a, l.b,1.c, 1.d, i.e (5)
HV-141 F028 D MSIV omatic Valve 1.a, 1.b, 1.c, 1.d, 1.e
( 5 )-
HV-141 F032 A Feedwater Isolation Valve Power Operated N/A Check HV-141 F032 B Feedwater Isolation Valve Power Operated N/A Check XV-141 F009 Nuclear Boiler EFCV Excess Flow Check N/A Valve XV-141 F070 A Nuclear Boiler EFCV Excess Flow Check WNA Valve XV-141 F070 B Nuclear Boiler EFCV Excess Flow Check N/A
.alve XV-141 F070 C Nuclear Boiler EFCV Excess Flow Check N/A Valve XV-141 F070 D Nuclear Boiler EFCV Excess Flow Check N/A
-, /
-Valve XV-141 F071 A Nuclear Boiler EFCV Excess Flow Check N/A Valve XV-141 F071 B Nuclear Boiler EFCV Excess Flow Check N/A Valve XV-141 F071 C Nuclear Boiler EFCV Excess Plow Check N/A Valve XV-141 F071 D lNuclear Boiler EFCV Excess Flow Check N/A
.Valve SUSQUEHANNA - UNIT 1 TS/IB 3.-3 3
.:Revision 1
.~~
Ii I'i iw I IW) 1.-.,
I If PPL Rev. 3 PCIVs B 3.6.1.3 Table B 3.6.1.3-1 (continued)
Primary Containment Isolation Valve (Page 5 of 11)
Isolation Signal Plant System Valve Number Valve Description Type of Valve L
mm I3olation Ti.me (Seconds))
Nuclear Boiler XV-1 41 F072 A Nuclear Boiler EFCV Excess Flow Check N/A Valve (continued) av XV-141 F072 B Nuclear Boiler EFCV.
Excess Flow Check NlA auve XV-141 F072 D Nuclear Boiler EFCV Excess Flow Check N/A alve
-141 F073 A Nuclear Boiler EFCV Excess Flow Check N/A Valve XV-141 F073 A Nuclear Boiler EFCV Excess Flow Check N/A Valve XV-141 F073 C Nuclear Boiler EFCV Excess Flow Check N/A Valve X___by
-141 F073 D Nuclear Boiler EFCV Excess Flow Check NIA Valve Nuclear Boiler XV-14201 Nuclear Boiler Vessel Instrument Excess Flow Check N/A Vessel Valve Instrumentation
-14202 Nuclear Boiler Vessel Instrument Excess Flow Check N/A Valve XV-142F041 Nuclear Boiler Vessel Instrument Excess Flow Check N/A Valve XV-142F043 A Nuclear Boiler Vessel Instrument Excess Flow Check N/A Valve' XV-142F043 B Nuclear Boiler Vessel Instrument Excess Flow Check N/A Valve XV-142F045 A Nuclear Boiler Vessel Instrument Excess Flow Check N/A Valve XV-142F045 B Nuclear Boiler Vessel Instrument Excess Flow Check N/A
-alve
-142F047 A Nuclear Boiler Vessel Instrument Excess Row Check N/A Valve XV-142F047 B.
Nuclear Boiler Vessel Instrument Excess Flow Check N/A
.Valve
.V-142F051 A Nuclear Boiler Vessel Instrument l
heck N/A Valve X-142F051 B Nuclear Boiler Vessel Instrument Excess Flow Check N/A Valve X-1 42F051,C Nuclear Boiler Vessel Instrument Excess Flow Check N/A Valve X-1142F051 D Nuclear Boiler Vessel Instrument Excess Flow Check N/A X-142F053 A Nuclear Boiler Vessel Instrument Excess Flow Check W/A.
Valve X-142F053 B Nuclear Boiler Vessel Instrument Excess Flow Check W/A V alv e_
I I
I, 6
I I
I i
i, I
II.
1 i
i II
(,W)
I' SUSQUEHANNA-UNIT 1 B 3.6-34 Revision 0 I
i f1410) 1.
I I
I iIi i -
I I
I
I I
I I I PPL Rev' 3 PCIVVs B 3.6.1.3 Table B 3.6.1.3-1 (continued)
Primary Containment Isolation Valve (Page 6 of II)
Isolation Signal LCO 3.3.6.1 Function No.
Plant System Valve Number Valve Description Type of Valve (am Isolation
.r Time (Seconds))
Nuclear Boiler XV-142F053 C Nuclear Boiler Vessel Instrument Excess Flow Check N/A Vessel Valve Instrumentation XV-142F053 D Nuclear Boiler Vessel Instrument Excess Flow Check N/A (continued)
Valve XV-142F055 Nuclear Boiler Vessel Instrument Excess Flow Check N/A
-Valve XV-142F057 Nuclear Boiler Vessel Instrument Excess Flow Check N/A Valve XV-142F059 A Nuclear Boiler Vessel Instrument Excess Flow Check N/A Valve XV-142F059 B Nuclear Boiler Vessel Instrument Excess Flow Check N/A
.Valve XV-142F059 C Nuclear Boiler Vessel Instrument Excess Flow Check N/A Valve XV-142F059 D Nuclear Boiler Vessel Instrument Excess Flow Check N/A Valve -
XV-142F059 E Nuclear Boiler Vessel Instrument Excess Flow Check
.N/A Valve XV-142F059 F Nuclear Boiler Vessel Instrument Excess Flow Check N/A Valve XV-142F059 G Nuclear Boiler Vessel Instrument Excess Flow Check N/A
_V alve
-142F059 H Nuclear Boiler Vessel Instrument xcess Flow Check N/A
-Valve XV-142F059 L Nuclear Boiler Vessel Instrument Excess Flow Check N/A
_'_-_'_Valve XV-142F059 M Nuclear Boiler Vessel Instrument Excess Flow Check N/A Valve
-142F059 N Nuclear Boiler Vessel Instrument Excess Flow Check N/A Valve XV-142F059 P Nuclear Boiler Vessel Instrument Excess Flow Check N/A
'Valve XV-142F059 R Nuclear Boiler Vessel Instrument Excess Flow Check N/A Valve XV-142F059 S Nuclear Boiler Vessel Instrument Excess Flow Check N/A Valve
-V-142F059 T Nuclear Boiler Vessel Instrument Excess Flow Check N/A Valve XV-142F059 U Nuclear Boiler Vessel Instrument Excess Flow Check N/A Valve X-142F061 Nuclear Boiler Vessel Instrument Excess Flow Check N/A
_ _ _V alv e RBCCW HV-11313 RBCCW Automatic Valve 2c, 2.d (30)
HV-11314' RBCCW Automatic Valve 2.c, 2d (30)
HV-11345 RBCCW Automatic Valve 2.c, 2d (30)
HV-11346
'RBCCW Automatic Valve 2.c, 2.d (30) j i i (IW I i -i:,
I -,
I, -,
iIj IL - -
SUSQUEHANNA-UNIT 1 11 3.6-35 Revision 0
PPL Rev. 3 PCIVs B 3.6.1.3 Table B 3.6.1.3-1 (continued).
Primary Containment Isolation Valve (Page 7 of 11)
Isolation Signal Typeof Vlve LCO 3.3.6.1 Function No.
Plant System Valve Number:
Valve Description Type of Vave (Maximum Isolation
_Time (Seconds))
RCIC 1-49-020 (d)
RCIC INJECTION Manual N/A 149F021 (b)(c)(d)
RCIC Minimum Recirculation Flow Manual Check N/A 149F028 (a)(d)
RCIC Vacuum Pump Discharge Manual Check N/A 149F040 (a)(d)
RCIC Turbine Exhaust Manual Check N/A FV-1 49F01 9 (b)(c)
RCIC Minimum Recirculation Flow Power Operated N/A HV,149F007 RCIC Steam Supply Automatic Valve 4.a, 4.b, 4.c, 4.e, 4.f, 4.g (20)
HV-149F008 RCIC Steam Supply Automatic Valve 4.a. 4.b, 4.c, 4.e, 4.f,
_.4.
(20)
HV-149F013 RCIC Injection Power Operated N/A HV-149F031 (b)(c)
RCIC Suction Power Operated N/A HV-149F059 (a)
RCIC Turbine Exhaust Power Operated N/A HV-149F060 (a)
RCIC Vacuum Pump Discharge Power Operated N/A HV-149F062 RCIC Vacuum Breaker Automatic Valve 4.b, 4.d (10)
HV-149F084 RCIC Vacuum Breaker Automatic Valve 4.b, 4.d (10)
HV-149F088.
RCIC Steam Supply Automatic Valve 4.a, 4.b, 4.c, 4.e, 4.f, XV-149F044 A
-ExcssFloChe4.g (12)
XV-149F044 A RCIC Excess Flow Check N/A
__Valve XV-149F044 B RCIC Excess Flow Check N/A Valve XV-149F044 C RCIC Excess Flow Check N/A Valve X-1 49F044 D IRCIC Excess Flow Check N/A Valve RB Chilled H-HV-18781 Al RB Chilled Water Automatic Valve 2.c, 2.d (40)
Water System HV-18781 A2 RB Chilled Water omatic Valve 2.c,2d (40)
V-78Bi RB ChledWte*omatic Valve 2.c, 2.d (40)
HV-18781 B2 7 RB Chilled Water Automatic Valve 2.c. 2.d (40)
HV-187812 A RB Chilled Water Automatic Valve 2.c, 2.d (40)
HV-1 8782 A RB Chilled Water Automatic Valve 2.c, 2d (12)
HV-1 8782 A2 RB Chilled Water Automatic Valve 2.c, 2.d (12)
HV-18782 B2 RB Chilled Water Automatic Valve 2.c, 2.d (12)
HV-1 8782 B2 RB Chilled Water Automatic Valve 2.c, 2.d (12)
HV-1 8791 Al RB Chilled Water Automatic Valve 2.b, 2.d (15)
HV-1 8791 A2 RB Chilled Water Automatic Valve 2.b, 2.d (15)
HV-18791 B2 RB Chilled Water Automatic Valve -
2b, 2.d (15)
HV-1 87912 Al RB Chilled Water Automatic Valve 2.b, 2.d (15)
HV-1 8792 Al RB Chilled Water Automatic Valve 2.b, 2.d (8)
HV-1 8792 A2 :
RB Chilled Water --
Automatic Valve 2.b, 2 d (8)
HV-18792 BI RB Chilled Water Automatic Valve 2.b, 2 d (8)
H HV-18792 B2 RB Chilled Water Automatic Valve 2.b, 2d (8)
Reactor 143F013 A (d)
Recirculation Pump Seal Water Manual Check N/A Recirculation 143F013 B (d)
Recirculation Pump Seal Water
, Manual Check N/A if
. SUSQUEHANNA - UNIT 1 USU-N' TS/B3.6-36
-. Revision 1
. B 3.6.1.3 Table B 3.6.1.341 (continued)
Primary Containment Isolation Valve (Page 8 of I1)
.Isolation Signal Plant System Valve Number Valve Description Type of Valve 3Ft
.ae ur ype(Maximum Isolation
________________I_____Time (eod)
Reactor Recirculation (continued)
XV-1 43F003 A Reactor Recirculation Excess Flow Check Valve N/A XV-143F003 B Reactor Recirculation Excess Flow Check NIA V: alve -
XV-143F004 A Reactor Recirculation Excess Flow Check N/A Valve XV-143F004 B Reactor Recirculation Excess Flow Check N/A
'alve XV-1 43F009 A Reactor Recirculation Excess Flow Check N/A
,alve XV-143F009 B Reactor Recirculation, Excess Flow Check N/A
.alve XV-143F009 C Reactor Recirculation Excess Flow Check N/A
- alve XV-143F009 D Reactor Recirculation Excess Flow Check N/A Valve XV-143F010 A Reactor Recirculation Excess Flow Check N/A alve XV-143F010 B Reactor Recirculation Excess Flow Check N/A Valve XV-143F010 C Reactor Recirculation Excess Flow Check N/A
,V alve XV-143F0110 D Reactor Recirculation Excess Flow Check N/A Valve -_:
XV-143F01A B Reactor Recirculation Excess Flow Check N/A Valve -
XV-143F01 1 B Reactor Recirculation Excess Flow Check N/A D,
alve XV-143F01 I C Reactor Recirculation Excess Flow Check N/A Valve
-143F011 D Reactor Recirculation Excess Flow Check N/A Valve XV-143F012 A Reactor Recirculation Excess Flow Check N/A Valve XV-143F012 B Reactor Recirculation Excess Flow Check N/A Valve.
-143F012C eactor Recirculation Excess Flow Check N/A
- Valve
- 143F01 2 D Reactor Recirculation Excess Flow Check N/A Valve
-143F01 7 A Recirculation Pump Seal Water Excess Flow Check N/A' a l v e
-43F017 B Recirculation Pump Seal Water Excess Flow Check N/A ave XV-1 43F040 A Reactor Recirculation Excess Flow Check
/alve I N/A
'fi'
'l I
I SUSQUEHANNA - UNIT; 1 I
I
} -
L_:.:
.B 3.6-37 Revision 0 ,..
II i
I(qw).
i - -
PPL Rev. 3
~PCI Vs B 3.6.1.3 Table B 3.6.1.3-1 (continued)
-Primary Containment Isolation Valve (Page 9 of 11)
Isolation Signal Plant System Valve Number Valve Description Type of Valve3.36.1 Funcion No.
Type f Vave (Maximum Isolation Time (Seconds))
Reactor XV-143F040 B Reactor Recirculation Excess Flow Check N/A Recirculation Valve (continued)
XV-143F040 C Reactor Recirculation Excess Flow Check N/A Valve XV-143F040 D Reactor Recirculation Excess Flow Check N/A Valve XV-143F057 A Reactor Recirculation Excess Flow Check N/A V alve XV-143F057 B Reactor Recirculation Excess Flow Check N/A Valve HV-143F019 Reactor Coolant Sample Automatic Valve 2.b (9)
HV-143F020 Reactor Coolant Sample Automatic Valve 2.b (2)
Residual Heat HV-151 F004 A (b)(c)
RHR - Suppression Pool Suction.
Power Operated N/A Removal H-1 51 F004 B (b)(c) RHR - Suppression Pool Suction Power Operated N/A HV-151 F004 C (b)(c)
RHR - Suppression Pool Suction Power Operated N/A HV-1 51 F004 D (b)(c)
RHR - Suppression Pool Suction Power Operated N/A
.HV-151 F007 D (b)(c) RHR - Suppression Porlation Power Operated N/A HV-151 F007 A (b)(c)
RHR-Minimum Recirculation Flow Power Operated N/A HV-151F007 B (b)(c) RHR-Minimum Recirculation Flow Power Operated N6A HV-151 F008 RHR - Shutdown Cooling Suction Automatic Valve 6.a, 6.b, 6.c (52).
. HV-1 51 F009 :
RHR - Shutdown Cooling Suction Automatic Valve -
6.a, 6.b, 6.c (52)
HV-151 F01 1 A (b)(d) RHR-Suppression Pool Manual N/A Cooling/Spray HV-151F01f B (b)(d) RHR-Suppression Pool Manual N/A Cooling/Spray HV-151 FO15 A RHR - Shutdown Cooling Power Operated N/A RetumrLPCI Injection HV-151F015 B RHR - Shutdown Cooling Power Operated N/A ReturnlLPCI Injection HV-151 F016 A (b)
RHR - Drywell Spray Automatic Valve 2.c. 2.d (90)
HV-151 F016 B (b)
RHR - Drywell Spray Automatic Valve 2.c, 2.d (90)
HV-151 F022 RHR - Reactor Vessel Head Spray Automatic Valve 2.d, 6.a, 6.b, 6.c (30)
HV-151 F023 RHR - Reactor Vessel Head Spray Automatfc Valve 2d, 6.a, 6.b, 6.c (20)
HV-151F028A(b)
RHR - Suppression Pool Automatic Valve 2.c, 2.d (90)
CoolinglSpray HV-1 51 F028 B (b)
RHR - Suppression Pool Automatic Valve 2.c, 2.d (90)
.Cooling/Spray HV-1 51 F050 A RHR - Shutdown Cooling Ar Operated Check N/A ReturnlLPCI Injection Valve Valve HV-151 F050 B RHR - Shutdown Cooling Air Operated Check N/A Retum/LPCI Injection Valve Valve
- HV-151F103A (b)
RHR Heat Exchanger Vent Power Operated N/A
_HV-151 F103 B (b)
RHR Heat Exchanger Vent Power Operated N/A I.
i,,:
ii "
(40
SUSQUEHANNA - UNIT 1 TS / B 3.6-38
- Revision 1
-----.-----.-
L ly I..
PPL Rev. 3 PCIVs B 3.6.1.3 Table B 3.6.1.3-1 (continued)
Primary Containment Isolation Valve (Page 10 of II)
Isolation Signal Plant System Valve Number Valve Description Type of Valve (laximum Isolation Time (Seconds))
Residual Heat HV-151 F122 A RHR - Shutdown Cooling Power.Operated N/A Removal ReturnlLPCI Injection Valve (Air)
(continued)
HV-151 F1 22 B RHR - Shutdown Cooling Power Operated N/A ReturnlLPCI Injection Valve (Air)
PSV-1 5106 A(b)(d)
RHR - Relief Valve Discharge Relief Valve IN/A PSV-1 5106 B (b)(d)
RHR - Relief Valve Discharge Relief Valve N/A PSV-1 51 F1 26 (d)
RHR - Shutdown Cooling Suction Relief Valve N/A XV-15109 A RHR Excess Flow Check N/A Valve XV-15109 :
RHR Excess Flow Check NIA Valve XV-15109 C RHR Excess Flow Check N/A Valve XV-15109 D RHR Excess Flow Check N/A Valve RWCU HV-144F001 (a)
RWCU Suction Automatic Valve 5.a, 5.b, 5.c, 5.d, 5.f,
_5.g (30)
HV-144F004 (a)
RWCU.Suction Auomatic Valve 5.a, 5.b, 5.c, 5.d, 5.e,
.5.f, 5.g (30)
XV-14411 A RWCU Excess Flow Check N/A Valve XV-14411 B RWCU Excess Flow Check N/A Valve XV-14411 C RWCU Excess Flow Check N/A Valve XV-14411 D RWCU Excess Flow Check N/A Valve X-144F046 RWCU
.Excess Flow Check N/A Valve HV-1 4182 A RWCU Return Isolation Valve Power Operated N/A
. HV-14182 B
. RWCU Retum Isolation Valve Power Operated NMA SLCS 148F007 (a)(d)
SLCS Manual Check N/A.
HV-148F006 (a)
SLCS Power Operated N/A
_Check Valve TIP System C51-J004 A (Shear TIP Shear Valves Squib Valves N/A Valve)
C51-J004 B (Shear TIP Shear Valves Squib Valves N/A Valve)
C51-J004 C (Shear TIP Shear Valves Squib Valves N/A V a lv e )_
C51-J004 D (Shear TIP Shear Valves Squib Valves N/A Valve)
C51-J004 E (Shear IP Shear Valves Squib Valves N/A
[V alve)
- SUISQUEHANNA-UNIT 1, I
I B 3.6-39
- Revision 0 I --
. I - -
-I --
I. - - -..
.I. - I.
i-PPL Rev. 3 PCI Vs-8 3.6.1.3 Table B 3.6.1.3-1 Primary Containment Isolation Valve (Page 11 of 11)
Isolation Signal LCO 3.3.6.1 Function No.
Plant System Valve Number Valve Description Type of Valve (am Isolation
_Time (Seconds))
TIP System C51-J004 A (Ball TIP Ball Valves Automatic Valve 7.a, 7.b (5)
(continued)'
Valve)
C51-JV04 B (Ball TIP Ball Valves Automatic Valve 7.a, 7.b (5)
Valve)
TIBlVlesAtoaicVav_*______5 C51-J004 C (Ball TIP Ball Valves Automatic Valve 7.a, 7.b (5)
V alve),-
C51-J004 D (Ball TIP Ball Valves Automatic Valve 7.a, 7.b (5)
Valve)'
C51-J004 E (Ball
- TIP Ball Valves Automatic Valve
.7a, 7.b (5)
Valve)
(a)
Isolation barrier remains water filled or a water seal remains in the line post-LOCA, isolation valve is tested with water. Isolation valve leakage is not included in 0.60 La total Type B and C tests.
(b)
Redundant isolation boundary for this valve is provided by the closed system whose integrity is verified by the Leakage Rate Test Program. This footnote does not apply to valve 1 55F046 (HPCI) when the associated PCIV, HVI 55F012 is closed and deactivated. Similarly, this footnote does not apply to valve 1 49F021 (RCIC) when it's associated PCIV, FV149F019 is closed and deactivated.
(c)
Containment Isolation Valves are not Type C tested. Containment bypass leakage is prevented since the line terminates below the minimum water level in tfie Suppression Chamber. Refer to the IST Program.
(d)
LCO 3.3.3.1, 'PAM Instrumentation", Table 3:3.3.1-1, Function 6, does not apply since these are relief valves, check valves, manual valves or deactivated and closed.
(e)
The containment isolation barriers for the penetration associated with this valve consists of two PCIVs and a closed system. The closed system provides a redundant isolation boundary for both PCIVs, and 'its integrity is required to be verified by the Leakage Rate Test Program.
SUSQUEHANNA - UNIT 1
. TS / B 3.6-40 Revision 4
Dec. 09, 2005 Page 1 of 1 MANUAL HARD COPY DISTRIBUTION DOCUMENT TRANSMITTAL 2005-53715 USER INFORMATION:
Name:GERLACH*ROSE M EMPL#:028401 CA#:0363 Address: NUCSA2 Phone#: 254-3194 TRANSMITTAL INFORMATION:
TO:
GERLACH*ROSE M 12/09/2005 LOCATION:
USNRC FROM:
NUCLEAR RECORDS DOCUMENT CONTROL CENTER (NUCSA-2)
THE FOLLOWING CHANGES HAVE OCCURRED TO THE HARDCOPY OR ELECTRONIC MANUAL ASSIGNED TO YOU.
HARDCOPY USERS MUST ENSURE THE DOCUMENTS PROVIDED MATCH THE INFORMATION ON THIS TRANSMITTAL.
WHEN REPLACING THIS MATERIAL IN YOUR HARDCOPY MANUAL, ENSURE THE UPDATE DOCUMENT ID IS THE SAME DOCUMENT ID YOU'RE REMOVING FROM YOUR MANUAL.
TOOLS FROM THE HUMAN PERFORMANCE TOOL BAG SHOULD BE UTILIZED TO ELIMINATE THE CHANCE OF ERRORS.
ATTENTION: "REPLACE" directions do not affect the Table of Contents, Therefore no lC will be issued with the updated material.
TSB2 -
TECHNICAL SPECIFICATIONS BASES UNIT 2 MANUAL REMOVE MANUAL TABLE OF CONTENTS DATE: 12/06/2005 ADD MANUAL TABLE OF CONTENTS DATE: 12/08/2005 CATEGORY:
ID:
TEXT REMOVE:
DOCUMENTS TYPE: TSB2 3.6.1.3 REV:2 ADD:
REV: 3 CATEGORY:
ID:
TEXT REMOVE:
DOCUMENTS TYPE: TSB2 LOES REV:65 ADD:
REV: 66 ANY DISCREPANCIES WITH THE MATERIAL PROVIDED, CONTACT DCS @ X3107 OR X3136 FOR ASSISTANCE. UPDATES FOR HARDCOPY MANUALS WILL BE DISTRIBUTED WITHIN 5 DAYS IN ACCORDANCE WITH DEPARTMENT PROCEDURES.
PLEASE MAKE ALL CHANGES AND ACKNOWLEDGE COMPLETE IN YOUR NIMS INBOX UPON COMPLETION OF UPDATES.
FOR ELECTRONIC MANUAL USERS, ELECTRONICALLY REVIEW THE APPROPRIATE DOCUMENTS AND ACKNOWLEDGE COMPLETE IN YOUR NIMS INBOX.
^%
SSES MANUAL
,k Manual Name: TSB2 Manual
Title:
TECHNICAL SPECIFICATIONS BASES UNIT 2 MANUAL I
Table Of Contents Issue Date:
12/08/2005 Procedure Name Rev Issue Date TEXT LOES 66 12/08/2005
Title:
LIST OF EFFECTIVE SECTIONS Change ID Change Number TprYr Tnc 7
D04/1812005
Title:
TABLE OF CONTENTS
(
TEXT 2.1.1 1
10/27/2004
Title:
SAFETY LIMITS (SLS) REACTOR CORE SLS TEXT 2.1.2 0
11/18/2002
Title:
SAFETY LIMITS (SLS) REACTOR COOLANT SYSTEM (RCS),PRESSURE SL TEXT 3.0 1
04/18/2005
Title:
LIMITING CONDITION FOR OPERATION 1LCO) APPLICABILITY TEXT 3.1.1 1
03/2412005
Title:
REACTIVITY CONTROL SYSTEMS SHUTDOWN MARGIN (SDM)
TEXT 3.1.2 1/18/2002
Title:
REACTIVITY CONTROLI>;SYSTEMS REACTIVITY ANOMALIES TEXT 3.1.3 07/06/2005
Title:
REACTIVITY!,CONTROL SYSTEMS CONTROL-ROD OPERABILITY TEXT 3.1.4 2
07/06/2005
Title:
REACTIVITY CONTROL SYSTEMS CONTROL ROD SCRAM TIMES TEXT 3.1.5 1
Title:
REACTIVITY CONTROL SYSTEMS TEXT 3.1.6 2
Title:
REACTIVITY CONTROL SYSTEMS 07/06/2005 CONTROL ROD'SCRAM ACCUMULATORS 03/24/2005 ROD PATTERN CONTROL P. e of 8R p r at : 1 / 8 0 Page 1 of 8
Report Date: 12/08/05
SSES MANUAL 9-.
Manual Name:
TSB2 Manual
Title:
TECHNICAL SPECIFICATIONS-BASES UNIT 2-MANUAL
- .)
v ?
u TEXT 3.1.7
Title:
REACTIVITY TEXT 3.1.8.
Title:
REACTIVITY CONTROL CONTROL TEXT 3.2.1
Title:
POWER TEXT 3.2.2
Title:
POWER 1
08/30/2005 SYSTEMS STANDBY LIQUID CONTROL (SLC)
SYSTEM 1
10/19/2005 SYSTEMS SCRAM DISCHARGE VOLUME (SDV)
VENT AND DRAIN VALVES 2
10/05/2005 LIMITS AVERAGE PLANAR LINEAR HEAT GENERATION RATE (APLHGR)
- 1.
1-03/24/2005 LIMITS MINIMUM CRITICAL POWER RATIO (MCPR) 0
-- 11/18/2002 LIMITS LINEAR HEAT GENERATION RATE (LHGR)
DISTRIBUTION DISTRIBUTION TEXT 3.2.3
Title:
POWER DISTRIBUTION
-EXT 3.2.4
Title:
POWER DISTRIBUTION 1
07/06/2005 LIMITS AVERAGE POWER RANGE MONITOR (APRM)
GAIN AND SETPOINTS 2
07/06/2005 TEXT 3.3,1.1
Title:
INSTRUMENTATION REACTOR PROTECTION SYSTEM (RPS) INSTRUMENTATION TEXT 3.3.1.2 0
11/18/2002
Title:
INSTRUMENTATION SOURCE RANGE MONITOR (SRM) INSTRUMENTATIQN TEXT 3.3.1.3
Title:
OPRM INSTRUMENTATION 0
11/22/2004 TEXT 3.3.2.1 1
02/17/2005 i : -:
Title:
INSTRUMENTATION CONTROL ROD BLOCK INSTRUMENTATION TEXT 3.3.2.2 0
.11/18/2002 -
Title:
INSTRUMENTATION FEEDWATER -
MAIN TURBINE HIGH WATER LEVEL TRIP INSTRUMENTATION TEXT 3.3.3.1 2
.07/06/2005
Title:
INSTRUMENTATION POST ACCIDENT MONITORING (PAM) INSTRUMENTATION Page 2
'of 8 Report Date: 12/08/05
SSES MANUAL I
v'Manual Name:
TSB2 Manual
Title:
TECHNICAL SPECIFICATIONS BASES UNIT 2 MANUAL dl TEXT 3.3.3.2 1
04/18/2005
Title:
INSTRUMENTATION REMOTE SHUTDOWN SYSTEM TEXT 3.3.4.1 0
11/18/2002
Title:
INSTRUMENTATION END OF CYCLE RECIRCULATION PUMP TRIP (EOC-RPT) INSTRUMENTATION TEXT 3.3.4.2 0
11/18/2002
Title:
INSTRUMENTATION ANTICIPATED TRANSIENT WITHOUT SCRAM RECIRCULATION PUMP TRIP (ATWS-RPT)
INSTRUMENTATION TEXT 3.3.5.1
Title:
INSTRUMENTATION TEXT 3.3.5.2
Title:
INSTRUMENTATION T EXT 3.3.6.1 (4
Title:
INSTRUMENTATION TEXT 3.3.6.2
Title:
INSTRUMENTATION TEXT 3.3.7.1
Title:
INSTRUMENTATION INSTRUMENTATION TEXT 3.3.8.1
- 3.
07/06/2005 EMERGENCY CORE COOLING SYSTEM (ECCS) INSTRUMENTATION 0
11/18/2002 REACTOR CORE ISOLATION COOLING (RCIC) SYSTEM INSTRUMENTATION 1
11/09/2004 PRIMARY CONTAINMENT ISOLATION INSTRUMENTATION 1
11/09/2004 SECONDARY CONTAINMENT ISOLATION INSTRUMENTATION 0
11/18/2002 CONTROL..ROOM EMERGENCY OUTSIDE AIR SUPPLY.(CREOAS)
SYSTEM 1
09/02/2004.'.
Title:
INSTRUMENTATION LOSSOF POWER (LOP) INSTRUMENTATION TEXT 3.3.8.2 0
11/18/2002
Title:
INSTRUMENTATION REACTOR PROTECTION SYSTEM (RPS) ELECTRIC POWER MONITORING TEXT 3.4.1 2
11/22/2004...
Title:
REACTOR COOLANT.SYSTEM (RCS).RECIRCULATION LOOPS OPERATING TEXT 3.4.2 0
11/18/2002-.
Title:
JET PUMPS Page3 of 8 Report Date: 12/08/05 Page 3 of 8 Report Date: 12/08/05
SSES MANUAL
.t Manual Name:
TSB2 7
- 0,
Manual
Title:
TECHNICAL SPECIFICATIONS BASES;UNIT 2 MANUAL.. :. '
(9, TEXT 3.4.3
. 0 11/18/2002'.
Title:
REACTOR COOLANT SYSTEM (RCS) SAFETY/RELIEF VALVES-(S/RVS)-
TEXT 3.4.4 0
- 11/18/2002
Title:
REACTOR-COOLANT SYSTEMA(RCS) RCSOPERALTIONAL LEAKAGE ' i TEXT 3.4.5
Title:
REACTOR 0
11/18/2002'. I I COOLANT SYSTEM.(RCS) RCS PRESSURE'ISOLATION VALVE (PIV) LEAKAGE I
....r ~. I-I,:
TEXT 3.4.6
Title:
REACTOR 1.
COOLANT SYSTEM (RCS) 04/18/2005
.RCS LEAKAGE DETECTION INSTRUMENTATION TEXT 3.4.7 1
04/18/2005:
Title:
REACTOR COOLANT SYSTEM (RCS).RCS SPECIFIC ACTIVITY o_
TEXT 3.4.8
Title:
REACTOR 1
04/18/2005 COOLANT SYSTEM (RCS)'RESIDUAL HEAT REMOVAL (RHR)
SHUTDOWN COOLING'SYSTEI&
HOT SHUTDOWN TEXT 3.4.9
.0
Title:
COLD SHUTDOWN 11/1'8/2002 0'
RESIDUAL HEAT REMOVAL :(RHR)7SHUTDOWN COOLING SYSTEM TEXT 3.4.10 0
11/18/2002
Title:
RCS PRESSURE AND TEMPERATURE (P/T) LIMITS TEXT 3.4.11 0
11/18/2002
Title:
REACTOR STEAM DOME PRESSURE TEXT 3.5.1 2
10/05/2005
Title:
EMERGENCY CORE COOLING:SYSTEMS (ECCS)
AND'REACTOR CORE ISOLATION COOLING:(RCIC)
SYSTEM ECCS -
OPERATING TEXT 3.5.2 0
11/18/2002
Title:
EMERGENCY CORE COOLING SYSTEMS (ECCS) AND'REACTOR CORE ISOLATION COOLING '(RCIC)
SYSTEM ECCS -
SHUTDOWN TEXT 3.5.3 1
04/18/2005
Title:
EMERGENCY CORE COOLING SYSTEMS (ECCS) AND REACTOR CORE ISOLATION COOLING (RCIC)
SYSTEM RCICSYSTEM Page4 of 8 Report Date: 12/08/05
' Page 4 pof8-:
- .,O
.8'.I Report Date:.12/08/05'- -'
-v SSES MANUAL
- Manual Name:
TSB2 Manual
Title:
TECHNICAL SPECIFICATIONS BASES UNIT 2 MANUAL TEXT 3.6.1.1
Title:
CONTAINMENT TEXT 3.6.1.2
Title:
CONTAINMENT 0
11/18/2002 SYSTEMS PRIMARY CONTAINMENT 0
11/18/2002 SYSTEMS PRIMARY CONTAINMENT AIR LOCK TEXT 3.6.1.3
Title:
CONTAINMENT 3
12/08/2005 SYSTEMS PRIMARY CONTAINMENT ISOLATION VALVES (PCIVS)
TEXT 3.6.1.4
Title:
CONTAINMENT TEXT 3.6.1.5
Title:
CONTAINMENT
'EXT 3.6.1.6
Title:
CONTAINMENT TEXT 3.6.2.1
Title:
CONTAINMENT TEXT 3.6.2.2
Title:
CONTAINMENT TEXT 3.6.2.3
Title:
CONTAINMENT TEXT 3.6.2.4
Title:
CONTAINMENT TEXT 3.6.3.1
Title:
CONTAINMENT TEXT 3.6.3.2
Title:
CONTAINMENT
- 0..
11/18/2002 SYSTEMS CONTAINMENT PRESSURE 1
10/05/2005 SYSTEMS DRYWELL AIR TEMPERATURE
- 0.
11/18/2002 SYSTEMS SUPPRESSION CHAMBER-TO-DRYWELL VACUUM BREAKERS 0
11/18/2002 SYSTEMS SUPPRESSION POOL AVERAGE TEMPERATURE 0
11/18/2002 SYSTEMS SUPPRESSION POOL WATER LEVEL 0
11/18/2002 SYSTEMS RESIDUAL HEAT REMOVAL (RHR)
SUPPRESSION POOL COOLING:
0 11/18/2002 SYSTEMS RESIDUAL HEAT REMOVAL (RHR) SUPPRESSION POOL SPRAY 1
04/18/2005-SYSTEMS PRIMARY CONTAINMENT HYDROGEN RECOMBINERS 1
04/18/2005:
SYSTEMS DRYWELL AIR FLOW SYSTEM PageS of 8 Report Date: 12/08/05 Page 5 of 8 Report Date: 12/08/05
SSES -MANUAL Manual Name: TSB2 Manual
Title:
TECHNICAL SPECIFICATIONS BASES UNIT 2 MANUAL.
U TEXT 3.6.3.3 0
11/18/2002:'
Title:
CONTAINMENT SYSTEMS PRIMARY CONTAINMENT OXYGEN CONCENTRATION TEXT 3.6.4.1 4
10/24/2005.--
Title:
CONTAINMENT SYSTEMS SECONDARY CONTAINMENT TEXT 3.6.4.2 2
01/03/2005'
Title:
CONTAINMENT SYSTEMS SECONDARY CONTAINMENT ISOLATION VALVESA(SCIVS)
TEXT 3.6.4.3
- 3.
. 10/24/2005
Title:
CONTAINMENT SYSTEMS STANDBY GAS TREATMENT. (SGT)' SYSTEM TEXT 3.7.1
.I
Title:
PLANT SYSTEMS ULTIMATE HEAT 0
11/18/2002 RESIDUAL HEAT REMOVAL SERVICE WATER (RHRSW) SYSTEM AND THE' SINK (UHS)
-'EXT 3.7.2 1
11/09/2004
Title:
PLANT SYSTEMS EMERGENCY SERVICE WATER (ESW) SYSTEM' U
TEXT 3.7.3
Title:
PLANT SYSTEMS 0
11/18/2002 CONTROL ROOM EMERGENCY OUTSIDE AIR SUPPLY (CREOAS)
'SYSTEM TEXT 3.7.4 0
11/18/2002
Title:
PLANT SYSTEMS CONTROL ROOM FLOOR COOLING SYSTEM TEXT 3.7.5
Title:
PLANT'SYSTEMS 0
11/18/2002 '
MAIN CONDENSER OFFGAS TEXT 3.7.6 1
01/17/2005
Title:
PLANT SYSTEMS MAIN TURBINE BYPASS SYSTEM TEXT 3.7.7 0
11/18/2002
Title:
PLANT SYSTEMS SPENT FUEL STORAGE POOL WATER LEVEL '
TEXT 3.8.1 3
10/05/2005
Title:
ELECTRICAL POWER SYSTEMS AC SOURCES -
OPERATING.
U R t D Report Date: 12/08/05' -I Page 6 of 8 Page 6 1.of.8.
SSES MANUAL w Manual Name: TSB2 Manual
Title:
TECHNICAL SPECIFICATIONS BASES UNIT 2 MANUAL TEXT 3.8.2 0
11/18/2002
Title:
ELECTRICAL POWER SYSTEMS AC SOURCES -
SHUTDOWN TEXT 3.8.3
Title:
ELECTRICAL TEXT 3.8.4
Title:
ELECTRICAL 0
POWER SYSTEMS 0
POWER SYSTEMS 11/18/2002 DIESEL FUEL OIL, LUBE OIL, AND STARTING AIR 11/18/2002 DC SOURCES -
OPERATING TEXT 3.8.5
- 0.
11/18/2002
Title:
ELECTRICAL POWER SYSTEMS DC SOURCES - SHUTDOWN TEXT 3.8.6 0
11/18/2002
Title:
ELECTRICAL POWER SYSTEMS BATTERY CELL PARAMETERS "EXT 3.8.7 1
10/05/2005
)
Title:
ELECTRICAL POWER SYSTEMS DISTRIBUTION SYSTEMS OPERATING TEXT 3.8.8 0
11/18/2002
Title:
ELECTRICAL POWER SYSTEMS DISTRIBUTION SYSTEMS SHUTDOWN TEXT 3.9.1 0
11/18/2002
Title:
REFUELING OPERATIONS REFUELING EQUIPMENT INTERLOCKS TEXT 3.9.2 0
11/18/2002 L
Title:
REFUELING OPERATIONS REFUEL-POSITION ONE-ROD-OUT INTERLOCK TEXT 3.9.3 0
11/18/2002--.
Title:
REFUELING OPERATIONS.CONTROL.ROD POSITION TEXT 3.9.4 0
11/18/2002
Title:
REFUELING OPERATIONS CONTROL ROD POSITION INDICATION TEXT 3.9.5 0
11/18/2002
Title:
REFUELING OPERATIONS CONTROL ROD OPERABILITY -
REFUELING Page7 of 8
Report Date: 12/08/05 Page 7 of 8
.Report Date: 12/08/05
SSES MANUAL Manual Name: TSB2 Mianual
Title:
TECHNICAL SPECIFICATIONS BASES UNIT 2 MANUAL' TEXT 3.9.7 0
11/18/2002
Title:
REFUELING OPERATIONS RESIDUAL HEAT REMOVAL (RHR) 7-'HIGH WATER-LEVEL TEXT 3.9.8 0
11/18/2002
Title:
REFUELING OPERATIONS RESIDUAL HEAT REMOVAL (RHR) --LOW WATER LEVEL TEXT 3.10.1
Title:
SPECIAL TEXT 3.10.2
Title:
SPECIAL OPERATIONS OPERATIONS 0
11/18/2002 INSERVICE LEAK AND HYDROSTATIC TESTING'OPERATION
- 0.
11/18/2002 REACTORMODE SWITCH INTERLOCK TESTING' TEXT 3.10.3
Title:
SPECIAL "EXT 3.10.4
Title:
SPECIAL OPERATIONS OPERATIONS 0
11/18/2002 SINGLE CONTROL ROD WITHDRAWAL -
HOT SHUTDOWN
- 0.
11/18/2002 SINGLE CONTROL ROD'WITHDRAWAL -' COLD'SHUTDOWN
.I TEXT 3.10.5
Title:
SPECIAL TEXT 3.10.6
Title:
SPECIAL TEXT 3.10.7
Title:
SPECIAL OPERATIONS OPERATIONS OPERATIONS 0
11/18/2002 SINGLE CONTROL ROD'DRIVE (CRD)
REMOVAL -
REFUELING 0
11/18/2002 MULTIPLE CONTROL ROD WITHDRAWAL - REFUELING 1
03/24/2005 CONTROL ROD TESTING -
OPERATING TEXT 3.10.8
Title:
SPECIAL 1
03/24/2005 SHUTDOWN MARGIN (SDM)
TEST -
REFUELING OPERATIONS
( 9 PageB.
of 8 Report Date: 12/08/05 Page 8,; of :8-Report Date: 12/08/05-
I SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)
Section TOC litle Table of Contents B 2.0 SAFETY LIMITS BASES
-Page TS/ B 2.0-1 Page TS/ B 2.0-2 PageTS/B2.0-3 PageTS/B2.0-4 PageTS/B2.0-5 Pages B 2.0-6 through B 2.0-8
- Revision 7
1
- 1 2
3
- 4 1
0 B 3.0 LCO AND SR APPLICABILITY BASES Pages B 3.0-1 through B 3.0-4 Pages TS / B 3.0-5 through TS I B 3.0-7 Pages TS / B 3.0-8 through TS / B 3.0-9 Pages TS / B 3.0-10 through TS / B 3.0-12 Pages TS / B 3.0-13 through TS / B 3.0-15 7
Pages TS I B 3.0-16 and TS I B 3.0-17 B 3.1 REACTIVITY CONTROL BASES Pages B 3.1-1 through B 3.1-4,
PageTS/B3.1-5 Pages TS / B 3.1-6 and TS B3i-r7J /
Pages B 3.1-8 through B 3.1-13LŽx--
PageTS/B3.1-14 /
s-._
Pages B 3.1-15 through B 3.1-22 PageTS/B3.1-23,,
\\
V Pages B 3.1-24through B 3.1-27 Page TS /B3A8:28\\
Page TS/3%4-29_>
\\
PagesJB3.1-30 through B 3.1-33 Pages TS)tIB 3?h34 through TS I B 3.1-36 P age e
LBb3.1-37 9Page'TS I.B 3.1-38 Page6 3.1-39 through B 3.1-44 PgeTS l B 3.1-45 Pages B 3.1-46 and B 3.1-47 PagesTSIB3.1-48andTSJB3.1-49 Page B 3.1-50 Page TS B 3.1-51 I1 2.
1 2
0 0
12 0
- 1*
2 1O
.I I 2 2
0.
1 0*1 I
~
B 3.2 POWER DISTRIBUTION LIMITS BASES Pages TS / B 3.2-1 and TS B 3.2-2 Page TS /B 3.2-3 Page TS / B 3.2-4 Pages TS / B 3.2-5 and TS B 3.2-6 Page TS/B3.2-7
_i Pages TS I B 3.2-8 and TS I B 3.2-9 I
3 1 '
3 2
3 qw SUSQUEHANNA - UNIT 2 TSIB LOES-1 Revision 66 L-
SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)
)
Section Title Pages TS / B 3.2-10 through TS / B 3.2-17 Page TS / 3.2-18 Page TS / 3.2-19 B 3.3 INSTRUMENTATION Pages TS / B 3.3-1 through TS I B 3.3-4 Page TS /B 3.3-5 Page TS/ B 3.3-6 PageTS/B3.3-7 Pages TS / B 3.3-8 through TS I B 3.3-11 Page TS / B 3.3-12 Page TS / B 3.3-13 Page TS / B 3.3-14 Pages TS / B 3.3-15 and TS / B 3.3-16 Pages TS / B 3.3-17 andTS / B 3.3-128 Pages TS / B 3.3-19 through TS / B 3.3-27 Pages TS / B 3.3-28 through TS / B 3.3-30 Page TS / B 3.3-31 PageTS/B3.3-32.
Page Ts / B 3.3-33 Pages TS / B 3.3-34 through TS I B 3.3-43 Pages TS / B 3.3-43a though TS I B 3.3-43i Pages TS / B 3.3-44 through TS I B 3.3-54 Pages B 3.3-55 through B 3.3-63 Pages TS / B83.3-64 and TS / B 3.3-65 Page TS / B 3.3-66 Page TS / B 3.3-67 Page TS / B 3.3-68 Pages TS / B 3.3-69 and TS /B 3.3-70 Pages TS / B 3.3-71 Pages TS / B 3.3-72 through TS I B 3.3-75 Page TS / B 3.3-75a Pages TS I B 3.3-75b and TS I B 3.3-75c Pages B 3.3-76 through TS I B 3.3-77 Page TS /B3.3-78 Pages B 3.3-79 through B 3.3-91 Pages TS / B 3.3-92 through TS I B 3.3-103 Page TS / B 3.3-104 Pages TS / B 3.3-105 and TS i B 3.3-106 Page TS / B3.3-107 Page TS B 3.3-108 Page TS /B3.3-109 Pages TS / B 3.3-110 through TS/ B 3.3-112 Page TS/ B3.3-113 Page TS I B 3.3-114 PageTS/B3.3-115 Revision 1
2 1
I 2
I 2
2 2
I 2
I 2
2 I
3 2
I0 2
.0 24 3
4 3
3 2
4 4
0 I
0 I
2 I
2 I
2
.1 2
I 2
SUSQUEHANNA - UNIT 2 ITS /B LOES-2
.Revision 66
SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)
Section T itle Pages TS / B 3.3-116 through TS / B 3.3-118 Pages TS / B 3.3-119 through TS / B 3.3-120 Pages TS / B 3.3-121 and TS I B 3.3-122 Page TS / B 3.3-123 Page TS / B 3.3-124 Page TS / B 3.3-124a Page TS / B 3.3-125 Page TS / B 3.3-126 Page TS / B 3.3-127 Page TS / B 3.3-128 Pages TS / B 3.3-129 through TS I B 3.3-131 Page TS / B 3.3-132 Pages TS I B 3.3-133 and TS / B 3.3-134 Pages B 3.3-135 through B 3.3-137 Page TS / B 3.3-138 Pages B 3.3-139 through B 3.3-149-Pages TS/ B 3.3-150 through TS I B 3.3-162 Page TS / B 3.3-163 Pages TS / B 3.3-164 through TS / B 3.3-177 Page TS/ B 3.3-178 Page TS/ B 3.3-179 Page TS / B 3.3-179a Page TS / B 3.3-180 Page TSi B 3.3-181 Pages TS / B 3.3-182 through-TS I B 3.3-186 Pages TS / B. 3.3-187 and TS / B 3.3-188 Pages TS / B 3.3-189 through TS I B 3.3-191 Pages B 3.3-192 through B 3.3-205 Page TS / B 3.3-206 Pages B 3.3-207 through B 3.3-220 Revision 2
2 2
1 2
3 2
2 0
I 2
23 2
2 0
0 1
2 1
2 3
2 1
.2 2
1 0
1 0
B 3.4 REACTOR COOLANT SYSTEM BASES Pages TS I B 3.4-1 and TS I B 3.4-2 Pages TS I B 3.4-3 through TS I B 3.4-9 Pages B 3.4-10 through B 3.4-14 Page TS'/ B 3.4-15.
Pages TS B 3.4-16 and TS B 3.4-17 Page TS/B3.4-18 Pages B 3.4-19 through B 3.4-28
-Page TS lB 3.4-29 Pages B 3.4-30 through B 3.3-31 Page TS /B 3.4-32 Pages B 3.4-33 through B 3.4-36 Page TS I B 3.4-37 Pages B 3.4-38 through B 3.4-40 Page TS / B 3.4-41
- 1 3
0 1
2 0
0 1
.1
-. I
-1 I
-I (W)
SUSQUEHANNA
- UNIT 2 TSIBLOES-3 Revision 66 SUSQUEHANNA - UNIT 2-
.TS / B LOES-3 Revision 66
SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)
Section Title Pages B 3.4-42 through B 3.4-48 Page TS / B 3.4-49 Page TS / B 3.4-50 Page TS / B 3.4-51 Pages TS I B 3.4-52 and TS I B 3.4-53 Pages TS / B 3.4-54 and TS / B 3.4-55 Pages TS / B 3.4-56 through TS I B 3.4-60 B 3.5 ECCS AND RCIC BASES Pages TS / B 3.5-1 and TS I B 3.5-2 Pages TS / B 3.5-3 through TS / B 3.5-6 Pages TS / B 3.5-7 through TS / B 3.5-10 Page TS / B3.5-11 Pages TS / B 3.5-12 through TS / B 3.5-14 Pages TS I B 3.5-15 and TS I B.3.5-16 Page TS B 3.5-17 Page TS B/3.5-18 Pages B 3.5-19 through B 3.5-24 Pages TS / B 3.5-25 through TS I B 3.5-27 Pages B 3.5-28 through B 3.5-31 B 3.6 CONTAINMENT SYSTEMS BASES Page TS / B 3.6-1 Page TS / B 3.6-1a Pages TS I B 3.6-2 through TS IB 3.6-5 PageTSlB3.6-6 Pages TS / B 3.6-6a and TS I B 3.6-6b Page TS I B 3.6-6c Pages B 3.6-7 through B 3.6-14 Page TS I B 3.6-15 Pages TS / B 3.6-15a and TS / B 3.6-15b Page TSI B 3.6-16 Page TS I B 3.6-17 PageTS B 3.6-17a Pages TS / B 3.6-18 and TS I B 3.6-19 PageTS/B3.6-20' Page TS/ B 3.6-21 Pages TS I B 3.6-21a and TS I B 3.6-21b Pages TS/ 83.6-22 and TS B 3.6-23 Pages TSIB 3.6-24 and TS B 3.6-25' PageTSlB3.6-26'.
Page TS IB 3.6-26 Page TS /B 3.6-27 Page TS / B 3.6-28 Page TS /8B3.6-29 Page TS / B 3.6-29a Page TS / B 3.6-30 Revision 0
2 1
2 1
2 i1
-1 2
.1 2
- 1 2
3 1
0 O 1
0 2
. 3 23 2
0 0
3 0
1.
2 0
I 2
3 O0 2
1 2
3 6
3 0
2 SUSQUEHANNA-UNIT 2 TS/BLOES-4 Revision 66
.. SUSQUEHANNA -UNIT 2
.TS /'B LOES-4 Revision 66
SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)
Section litle Page TS /.B 3.6-31 Page TS / B 3.6-32 Page TS / B 3.6-33 Page TS / B 3.6-34 Pages TS / B 3.6-35 through TS I B 3.6-37 Page TS/ B 3.6-38 Page TS I B 3.6-39 Pages B 3.6-40 through B 3.6-42 Pages TS / B 3.6-43 and TS I B 3.6-44 Page TS / B 3.6-45 Pages TS / B 3.6-46 through TS I B 3.6-50 Page TS / B 3.6-51 Pages B 3.6-52 through B 3.6-62 Page TS / B 3.6-63 Pages B 3.6-64 through B 3.6-70 Page B 3.6-71 PageTS/B3.6-72 Pages B 3.6-73 through B 3.6-76 Page TS / B 3.6 Pages B 3.6-78 through B 3.6-82 Page TS / B 3.6-83 Page TS / B 3.6-84 Page TS/B3.6-85 Page TS / B 3.6-86 Pages TS / B 3.6-87 and TS /B 3.6-87a Page TS I B 3.6-88 Page TS / B 3.6-89 Page TS I B 3.3-90 Pages TS / B 3.6-91 through TS I B 3.6-95 Page TS / B 3.6-96 Pages TS / B 3.6-97 and TS / B 3.6-98 Page TS I B 3.6-99 Page TS I B 3.6-99a PagesTS/B3.6-100 and TS/ B 3.6-101 Pages TS I B 3.6-102 and TS I B 3.6-103 Page TS / B 3.6-104 Pages TS I B 3.6-105 and TS I B 3.6-106 B 3.7 PLANT SYSTEMS BASES Pages TS / B 3.7-1 through TS I B 3.7-6 Page TS / B 3.7-6a Pages TS / B3.7-6b and TS/ B 3.7-6c Page TS / B 3.7-7 Page TS / B 3.7-8 Pages B 3.7-9 through B 3.7-11 Pages TS B 3.7-12 and TS B 3.7-13 Revision 3
2 2
I1 2
5 0
I 2
0 20 0
I 0
10 3
2 3
- 2 3 1
3 1
2 1
2 0
1 2
3 2
20
- 2:
- I
'0 1
I SUSQUEHANNA - UNIT 2 TS J B LOES-5 Revision 66
SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)
Section Title Pages TS / B 3.7-14 through TS I B 3.7-18 Page TS / B 3.7-18a Pages TS / B 3.7-19 through TS / B 3.7-26 Pages B 3.7-24 through B 3.7-26 Pages TS / B 3.7-27 through TS / B 3.7-29 PageTS/B3.7-30 Pages B 3.7-31 through B 3.7-33 B 3.8 ELECTRICAL POWER SYSTEMS BASES Pages B 3.8-1 through B 3.8-4 Pages TS / B 3.8-5 and Page TS I B 3.8-6 Pages B 3.8-7 and B 3.8-8 PageTS/B3.8-9 Pages TS / B 3.8-10 and TS / B 3.8-11 Pages B 3.8-12 through B 3.8-18 Page TS / B 3.8-19 Pages B 3.8-20 through B 3.8-22 Page TS / B 3.8-23 Page B 3.8-24 Pages TS I B 3.8-25 and TS I B 3.8-26 Pages B 3.8-27 through B 3.8-37 Page TS / B 3.8-38 Pages TS / B 3.8-39 through TS I B 3.8-55
- Pages TS I B 3.8-56 through TS / B 3.8-64 Page TS / B 3.8-65 and Page-TS / B 3.8-66 Pages TS I B. 3.8-67 and TS i B 3.8-68 Page TS / B 3.8-69 Pages B 3.8-70 through B 3.8-85 Page TS /B3.8-86 and TS I B 3.8-87 Pages B 3.8-88 through B 3.8-99 Revision 2
0 0
2 I
0 0
2 1
0 0
0 1
0
.1 2
2 0
0 11
B 3.9 REFUELING OPERATIONS BASES Pages TS / B 3.9-1 and TS I B 3.9-2 Page TS / B 3.9-2a Pages TS / B 3.9-3 and TS / B 3.9-4 Pages B 3.9-5 through B 3.9-30 1
I 0
B 3.10 SPECIAL OPERATIONS BASES Page TS / B 3.10-1 Pages B 3.10-2 through B 3.10-32 Page TS I B 3.10-33 Pages B 3.10-34 through B 3.10-38 Page TS/ B 3.10-39 TSB2LOES 11/21105 1
0 2
- 0 1 2 SUSQUEHANNA
- UNIT 2 TS I B LOES-6 Revision 66 SUSQUEHANNA - UNIT 2
.TS / B LOES-6
-- Revision 66 L
PPL Rev. 3 PCIVs B 3.6.1.3 B 3.6 CONTAINMENT SYSTEMS B 3.6.1.3 Primary Containment Isolation Valves (PCIVs)
BASES BACKGROUND The function of the PCIVs, in combination with other accident mitigation systems, is to limit fission product release during and following postulated Design Basis Accidents (DBAs) to within limits. Primary containment isolation within the time limits specified for those isolation valves designed to close automatically ensures that the release of radioactive material to the environment will be consistent with the assumptions used in the analyses for a DBA.
The OPERABILITY requirements for PCIVs help ensure that an adequate primary containment boundary is maintained during and after an accident by minimizing potential paths to the environment.
Therefore, the OPERABILITY requirements provide assurance that primary containment function assumed in the safety analyses will be maintained. For PCIVs, the primary containment isolation function is that the valve must be able to close (automatically or manually) and/or remain closed, and maintain leakage within that assumed in the DBA LOCA Dose Analysis. These isolation devices are either passive or active (automatic). Manual valves, de-activated automatic valves secured in their-closed position (including check valves with flow through the valve secured), blind flanges, and' closed systems are considered passive devices. 'The OPERABILITY requirements for closed systems are discussed in Technical Requirements Manual '(TRM) Bases 3.6.4. Check valves, or other automatic valves designed to close without operator action following an accident, are considered active devices. Two barriers in series are provided for each penetration so that no single credible failure or malfunction of an active component can result in a loss of isolation or leakage that exceeds limits assumed in the safety analyses. One of these barriers may be a closed system.
For each division of H202 Analyzers, the lines, up to and including the first normally closed valves within the H202 (continued)
SUSQUEHIANNA -UNIT 2 TS/B 3.6-15 Revision 3
PPL Rev. 3 PCIVs B 3.6.1.3 BASES BACKGROUND
- (continued)
Analyzer panels, are extensions of prirrary containment (i.e., closed system), and are required to be leak rate tested in accordance with the Leakage Rate Test Program. The H202 Analyzer closed system boundary is identified in the Leakage Rate Test Program. The closed system boundary consists of those components, piping, tubing, fittings, and valves, which meet the guidance of Reference 6. The closed system provides a secondary barrier in the event of a single failure of the PCIVs, as described below. The closed system boundary between PASS and the H202 Analyzer system ends at the process sampling solenoid operated isolation valves between the systems (SV-22361, SV-22365, SV-22366, SV-22368, and SV-22369).
These solenoid operated isolation valves do not fully meet the guidance of Reference 6 for closed system boundary valves in that they are not powered from a Class 1 E power source.
However, based upon a risk determination, operating these valves as closed system boundary valves is not risk significant These valves also form the end of the Seismic Category I boundary between the systems. These process sampling solenoid operated isolation valves are normally closed and are required to be leak rate tested in accordance with the Leakage Rate Test Program as part of the closed system for the H202 Analyzer system. These valves are uclosed system boundary valves" and may be opened under administrative control, as delineated in Technical Requirements Manual (TRM) Bases 3.6.4. Opening of these valves to permit testing of PASS in Modes 1, 2,.and 3 is permitted in accordance with TRO 3.6.4.
I r ( 40d I,.-
Each H202 Analyzer Sampling line penetrating primary containment has two PCIVs, located just outside primary containment While two PCIVs are provided on each line, a single active failure of a relay in the control circuitry for these valves, could result in both valves failing to close or failing to remain closed. Furthermore, a single failure (a hot short in the common raceway to all the valves) could simultaneously affect all of the PCIVs within a H202 Analyzer division. Therefore, the containment isolation barriers for these penetrations consist of two PCIVs and a closed system. For situations where one or both PCIVs are inoperable, the ACTIONS to be taken are similar to the ACTIONS for a single PCIV backed by a closed system.
(continued)
I SUSQUEHANNA - UNIT 2 I TS/B3..6-15a Revision 0
PPL Rev. 3 PCIVs B 3.6.1.3 BASES BACKGROUND The drywell vent and purge lines are 24 inches in diameter; (continued) the suppression chamber vent and purge lines are 18 inches in diameter. The containment purge valves are normally maintained closed in MODES 1, 2, and 3 to ensure the primary containment boundary is maintained. The outboard isolation valves have 2 inch bypass lines around them for use during normal reactor operation.
(W)
(continued)
SUSQUEHANNA - UNIT 2 TS i B 3.6-15b Revision 0
.W)
BASES (contir APPLICABLE SAFETY ANAL PPL Rev. 3 PCIVs B 3.6.1.3 ued)
The PCIVs LCO was derived from the assumptions related
.YSES to minimizing the loss of reactor coolant inventory, and establishing the primary containment boundary during major accidents. As part of the primary containment boundary, PCIV OPERABILITY supports leak tightness of primary containment. Therefore, the safety analysis of any event requiring isolation of primary containment is applicable to this LCO.
The DBAs that result in a release of radioactive material within primary containment are a LOCA and a main steam line break (MSLB). In the analysis for each of these accidents, it is assumed that PCIVs are either closed or close within the required isolation times following event initiation. This ensures that potential paths to the environment through PCIVs' (including primary containment purge valves) are minimized. Of the events analyzed in Reference 1, the MSLB is the most limiting event due to radiological consequences. The closure time of the main steam isolation valves (MSIVs) is a significant variable from a radiological standpoint. The MSIVs are required to close within 3 to 5 seconds since the 5 second closure time is assumed in the analysis. The safety analyses assume that the purge valves were closed at event initiation. Likewise, it is assumed that the primary containment is isolated such that release of fission products to the environment is controlled.
The DBA analysis assumes that within the required isolation time leakage is terminated, except for the maximun allowable leakage rate, La.
The single failure criterion required to be imposed in the conduct of unit safety analyses was considered in the original design of the primary containment purge valves. Two-valves in series on each purge line provide assurance that both the supply and exhaust lines could be isolated even if a single failure occurred.
I The primary containment purge valves may be unable to close in the environment following a LOCA. Therefore, each of the purge valves is required to remain closed during MODES 1, 2, and 3 except as permitted under Note 2 of SR 3.6.1.3.1. In this case, the single failure criterion remains applicable to the primary containment purge valve q
(continued)
SUSQUEHANNA - UNIT 2 TS / B 3.6-16 Revision 1
PPL Rev. 3 PCIVs B 3.6.1.3 BASES APPLICABLE SAFEETY ANALY' (continued) 315 due to failure in the control circuit assodiated with each valve. The primary containment purge valve design precludes a single failure from compromising the primary containment boundary as long as the system is operated in accordance with this LCO.
Both H202 Analyzer PCIVs may not be able to close given a single failure in the control circuitry of the valves. The single failure is caused by a 'hot short' in the cables/raceway to the PCIVs that causes both PCIVs for a given penetration to remain open or to open when required to be closed. This failure is required to be considered in accordance with IEEE-279 as discussed in FSAR Section 7.3.2a. However, the single failure criterion for containment isolation of the H202 Analyzer penetrations is satisfied by virtue of the combination of the associated PCIVs and the closed system formed by the H202 Analyzer piping system as discussed in the BACKGROUND section above.
The closed system boundary between PASS and the H202 Analyzer system ends at the process sampling solenoid operated isolation valves between the systems (SV-22361, SV-22365, SV-22366, SV-22368, and SV-22369). The closed system is not fully qualified to the guidance of Reference 6 in that the closed system boundary valves between the H202 system and PASS are not powered from a Class 1 E power source. However, based upon a risk determination, the use of these valves is considered to have no risk significance. This exemption to the requirement of Reference 6 for the closed system boundary is documented in License Amendment No. 170.
PCIVs satisfy Criterion 3 of the NRC Policy Statement. (Ref. 2)
I (M
. LC 0 PCIVs form a part of the primary containment boundary. The PCIV safety function is related to minimizing the loss of reactor coolant inventory and establishing the primary containment boundary during a DBA.
The power operated, automatic isolation valves are required to have isolation times within limits and actuate on an (41
(continued)
SUSQUEHANNA - UNIT 2
TS I B 3.617
Revision 2 I
I
PPL Rev. 3 PCIVs B 3.6.1.3 BASES LCO (continued) automatic isolation signal. The valves covered by this LCO are listed in Table B 3.6.1.3-1.
The normally closed PCIVs are considered OPERABLE when manual valves are closed or open in accordance with appropriate administrative controls, automatic valves are in their closed position, blind flanges are in place, and-closed systems are intact.
These passive isolation valves and devices are those listed in Table B 3.6.1.3-1.
Purge valves with resilient seals, secondary containment bypass valves, MSIVs, and hydrostatically tested valves must meet additional leakage rate requirements. Other PCIV leakage rates are addressed by LCO 3.6.1.1, "Primary Containment," as Type B or C testing.
This LCO provides assurance that the PCIVs will perform their designed safety functions to minimize the loss of reactor coolant inventory and establish the primary containment boundary during accidents.
APPLICABILITY In MODES 1, 2, and 3, a DBA could cause a release of radioactive material to primary containment. In MODES 4 and 5, the probability and consequences of these events are reduced due to the pressure and temperature limitations-of these MODES.
Therefore, most PCIVs are not required to be' (continued)
SUSQUEHANNA - UNIT 2 -
TS / B 3.6-17a Revision 0
n n
APPLICABILITY OPERABLE and the primary containment purge valves are (continued) not required to be closed in MODES 4 and 5. Certain valves, however, are required to be OPERABLE to prevent inadvertent reactor vessel draindown. These valves are those whose associated instrumentation is required to be OPERABLE per LCO 3.3.6.1, "Primary Containment Isolation Instrumentation."
(This does not include the valves that isolate the associated
'instrumentation.)
ACTIONS The ACTIONS are modified by a Note allowing penetration flow path(s) to be unisolated intermittently under administrative controls. These controls consist of stationing a dedicated operator at the controls of the valve, who is in continuous communication with the control room. In this way, the penetration can be rapidly isolated when a need for primary containment isolation is indicated.
A second Note has been added to provide clarification that, for the purpose of this LCO, separate Condition entry is allowed for each penetration flow path. This is acceptable, since the Required Actions for each Condition provide appropriate compensatory actions for each inoperable PCIV. Complying with the Required Actions may allow for continued operation, and subsequent inoperable PCIVs are governed by subsequent Condition entry and application of associated Required Actions.
The ACTIONS are modified by Notes 3 and 4. Note 3 ensures that appropriate remedial actions are taken, if necessary, if the affected system(s) are rendered inoperable by an inoperable PCIV (eig., an Emergency Core Cooling System subsystem is inoperable due to a failed open test return valve). Note 4 ensures appropriate remedial actions are taken when the primary containment leakage limits are exceeded. Pursuant to LCO 3.0.6, these actions are not required even when the associated LCO is not met. Therefore, Notes 3 and 4 are added to require the proper actions be taken.
A.1 and A.2 With one or more penetration flow paths with one PCIV inoperable except for purge valve leakage not within limit, (continued)
SUSQUEHANNA - UNIT 2 TS / B 3.6-18 Revision I
i I
PPL Rev. 3
-PCIVs B 3.6.1.3 BASES ACTIONS A.1 and A.2 (continued) the affected penetration flow paths must be isolated. The method of isolation must include the use of at least one isolation barrier that cannot be adversely affected by a single active failure.
Isolation barriers that meet this criterion are a closed and de-activated automatic valve, a closed manual valve, a blind flange, and a check valve with flow through the valve secured.
For a penetration isolated in accordance with Required Action A.1, the device used to isolate the penetration should be the closest available valve to the primary containment. The Required Action must be completed within the 4 hour4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> Completion Time (8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> for main steam lines). The Completion Time of 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> is reasonable considering the time required to isolate the penetration and the relative importance of supporting primary containment' OPERABILITY during MODES 1, 2, and 3. For main steam lines, an 8 hour9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> Completion Time is allowed. The Completion Time of 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> for the main steam lines allows a period of time to restore the MSIVs to OPERABLE status given the fact that MSIV closure will result in isolation of the main steam line(s) and a potential for plant shutdown.
For affected penetrations that have been isolated in accordance
(_)
with Required Action A.1, the affected penetration flow path(s) must be verified to be isolated on a periodic basis. This is necessary to ensure that primary containment penetrations required to be isolated following an accident, and' no longer capable of being automatically isolated, will be in the isolation position should an event occur. This Required Action does not require any testing or device manipulation. Rather, it involves verification that those devices outside containment and capable of potentially being mispositioned are in the. correct position. The Completion Time of "once per 31 days for isolation devices outside primary containment" is appropriate because the devices are operated under administrative controls and the probability of their misalignment is low. For the devices inside primary containment, the time period specified "prior to entering MODE 2 or 3 from MODE 4, if primary containment was de-inerted while in MODE 4, if not performed within the previous 92 days" is based on engineering judgment and is considered reasonable in view of the inaccessibility of the devices and other administrative controls ensuring that device misalignment is an unlikely possibility.
.(W
(continued)
SUSQUEHANNA - UNIT 2 UA UTS/B3.6-19.
Revision 1 -
PPL Rev. 3 PCIVs B 3.6.1.3 BASES ACTIONS A.1 and A.2 (continued)
Condition A is modified by a Note indicating that this Condition is only applicable to those penetration flow paths with two PCIVs except for the H202 Analyzer penetrations. For penetration flow paths with one PCIV, Condition C provides the appropriate Required Actions. For the H202 Analyzer penetrations, Condition D provides the appropriate Required Actions.
Required Action A.2 is modified by a Note that applies to isolation devices located in high radiation areas, and allows them to be verified by use of administrative means. Allowing verification by administrative means is considered acceptable, since access to these areas is typically restricted. Therefore, the probability of misalignment of these devices, once they have been verified to be in the proper position, is low.
B.1 With one or more penetration flow paths with two PCIVs inoperable except for purge valve leakage not within limit, either the inoperable PCIVs must be restored to OPERABLE status or the affected penetration flow path must be isolated within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />. The method of isolation must include the use of at least one isolation barrier that cannot be adversely affected by a single active failure. Isolation barriers that-meet this criterion are a closed and-de-activated automatic valve, a closed manual valve, and a blind flange. The 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> Completion Time is consistent with the ACTIONS of
-LCO 3.6.1.1.
Condition B is modified by a Note indicating this Condition is only applicable to penetration flow paths with Iwo PCIVs except for the H202 Analyzer penetrations. For penetration flow paths with one PCIV, Condition C provides the appropriate Required Actions. For the H202 Analyzer penetrations, Condition D provides the appropriate Required Actions.
C.1 and C.2 With one or more penetration flow paths with one PCIV inoperable, the inoperable valve must be restored to (continued)
SUSQUEHANNA - UNIT 2 TS IB 3.6-20 Revision 2
PPL Rev. 3 PCIVs B 3.6.1.3 BASES ACTIONS C.1 and C.2 (continued)
OPERABLE status or the affected penetration flow path must be isolated. The method of isolation must include the use of at least one isolation barrier that cannot be adversely affected by a single active failure. Isolation barriers that meet this criterion are a closed and de-activated automatic valve, a closed manual valve, and a blind flange. A check valve may not be used to isolate the affected penetration. Required Action C.1 must be completed within the 72 hour8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> Completion Time. The Completion Time of 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> is reasonable considering the relative stability of the closed system (hence, reliability) to act as a penetration isolation boundary and the relative importance of supporting primary containment OPERABILITY during MODES 1, 2, and 3. The closed system must meet the requirements of Reference 6. For conditions where the PCIV and the closed system are inoperable, the Required Actions of TRO 3.6.4, Condition B apply. For the Excess Flow Check Valves (EFCV), the Completion Time of 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> is reasonable considering the instrument and the small pipe diameter of penetration (hence, reliability) to act as a penetration isolation boundary and the small pipe diameter of the affected penetrations. In the event the affected penetration flow path is isolated in accordance with Required Action C.1, the affected penetration must be verified to be isolated on a periodic basis. This is necessary to ensure that primary containment penetrations required to be isolated following an accident are isolated. The Completion Time of once per 31 days for verifying each affected penetration is isolated is appropriate because the valves are operated under administrative controls and the probability of their misalignment is low.
Condition C is modified by a Note indicating that this Condition is only applicable to penetration flow paths with only one PCIV. For penetration flow paths with two PCIVs and the H202 Analyzer penetration, Conditions A, B, and D provide the appropriate Required Actions.
Required Action C.2 is modified by a Note that applies to valves and blind flanges located in high radiation areas and allows them to be verified by use of administrative means. Allowing verification by administrative means is considered acceptable, since access to these areas is typically (continued)
Qi
- SUSQUEHANNA - UNIT 2 TS/B3.6-21 R
-Revision 3
PPL Rev. 3 PCIVs B 3.6.1.3 BASES ACTIONS C.1 and C.2 (continued) restricted. Therefore, the probability of misalignment of these valves, once they have been verified to be in the proper position, is low.
D.1 and D.2
- With one or more H202 Analyzer penetrations with one or both PCIVs inoperable, the inoperable valve(s) must be restored to OPERABLE status or the affected penetration flow path must be isolated. The method of isolation must include the use of at least one isolation barrier that cannot be adversely affected by a single active failure. Isolation barriers that meet this criterion are a closed and de-activated automatic valve, a closed manual valve, and a blind flange. A check valve may not be used to isolate the affected penetration. Required Action D.1 must be completed within the 72 hour8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> Completion Time. The Completion Time of 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> is reasonable considering the unique design of the H202 Analyzer penetrations. The containment isolation barriers for these penetrations consist of two PCIVs and a closed system. In addition, the Completion Time of 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> is reasonable considering the relative stability of the closed system (hence, reliability) to act as a penetration isolation boundary and the relative importance of supportingprimary containment OPERABILITY during MODES 1, 2, and 3. In the event the affected penetration flow path is isolated in accordance with
-Required Action D.1, the affected penetration must be verified to be isolated on a periodic basis. This is necessary to ensure that primary containment penetrations required to be isolated following
- an accident are isolated. The Completion Time of once'per 31 days for verifying each affected penetration is isolated is appropriate because the valves are operated under administrative controls and the probability of their misalignment is low.
When an H202 Analyzer penetration PCIV is to be closed and deactivated in accordance with Condition D, this must be accomplished by pulling the fuse for the power supply, and either determinating the power cables at the solenoid valve, or jumpering of the power side of the solenoid to ground.
(continued)
SUSQUEHANNA - UNIT 2 TS IB 3.6-21 a Revision 0
PPL Rev. 3 PCIVs B 3.6.1.3 BASES ACTIONS D.1 and D.2 (continued}
The OPERABILITY requirements for the closed system are discussed in Technical Requirements Manual (TRM) Bases 3.6.4.
In the event that either one or both of the PCIVs and the closed system are inoperable, the Required Actions of TRO 3.6.4, Condition B apply.
Condition D is modified by a Note indicating that this Condition is only applicable to the H202 Analyzer penetrations.
I lI (continued)
SUSQUEHANNA - UNIT 2 TS / B3.6-21 b Revision 0
PPL Rev. 3 PCIVs B 3.6.1.3 BASES ACTIONS (continued)
E.1 I'
With the secondary containment bypass leakage rate not within limit, the assumptions of the safety analysis may not be met.
Therefore, the leakage must be restored to within limit within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />. Restoration can be accomplished by isolating the penetration that caused the limit to be exceeded by use of one closed and de-activated automatic valve, closed manual valve, or blind flange. When a penetration is isolated, the leakage rate for the isolated penetration is assumed to be the actual pathway leakage through the isolation device. If two isolation devices are used to isolate the penetration, the leakage rate is assumed to be the lesser actual pathway leakage of the two devices. The 4 hour4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> Completion Time is reasonable considering the time required to restore the leakage by isolating the penetration and the relative importance of secondary containment bypass leakage to the overall containment function.
F.1 4W -
In the event one or more containment purge valves are not within the purge valve leakage limits, purge valve leakage must be restored to within limits. The 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> Completion Time is reasonable, considering that one containment purge valve remains closed, except as controlled by SR.3.6.1.3.1 so that a gross breach of containment does not exist.
G.1 and G.2 I
I If any Required Action and associated Completion Time cannot be met in MODE 1, 2, or 3, the plant must be brought to a MODE in which the LCO does not apply. To achieve this status, the plant must be brought to at least MODE 3 within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> and to MODE 4 within 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br />. The allowed Completion Times are reasonable, based on operating experience, to reach the required plant conditions from full power conditions in an orderly manner and without challenging plant systems.
- SUSQUEHANNA - UNIT 2 (continued)
Revision 2 TS / B3.6-22
PPL Rev. 3 PCIVs B 3.6.1.3 BASES ACTIONS (continued)
H.1 and H.2 If any Required Action and associated Completion Time cannot be met, the unit must be placed in a condition in which the LCO does not apply. If applicable, action must be immediately initiated to suspend operations with a potential for draining the reactor vessel (OPDRVs) to minimize the probability of a vessel draindown and subsequent potential for fission product release. Actions must continue until OPDRVs are suspended or valve(s) are restored to OPERABLE status. If suspending an OPDRV would result in closing the residual heat removal (RHR) shutdown cooling isolation valves, an alternative Required Action is provided to immediately initiate action to restore the valve(s) to OPERABLE status. This allows RHR to remain in service while actions are being taken to restore the valve.
SURVEILLANCE REQUIREMENTS SR 3.6.1.3.1 This SR ensures that the primary containment purge valves are closed as required or, if open, open for an allowable reason. If a purge valve is open in violation of this SR, the valve is considered inoperable. If the inoperable valve is not otherwise known to have excessive leakage when closed, it is not considered to have leakage outside of limits. The SR is also modified by Note 1, stating that, primary containment purge valves are only required to be closed in MODES 1, 2, and 3. If a LOCA ifnside primary containment occurs in these MODES, the purge valves may not be capable of closing before the pressure pulse affects systems downstream of the purge valves, or the release of radioactive material will exceed limits prior to the purge valves closing. At other times when the purge valves are required to be capable of closing (e.g., during handling of irradiated fuel), pressurization concerns are not present and the purge valves are allowed to be open. The SR is modified by Note 2 stating that the SR is not required to be met when the purge valves are open for the stated reasons. The Note states that these valves may be opened for inerting, de-inerting, pressure control, ALARA or air quality considerations for personnel entry, or Surveillances that require the valves to be open. The vent and purge valves are capable of closing in the environment following (continued)
SUSQUEHANNA - UNIT 2 TS / B 1623 Revision 2
PPL Rev. 3 PCIVs B 3.6.1.3 BASES SURVEILLANCE SR 3.6.1.3.1 (continued)
REQUIREMENTS a LOCA. Therefore, these valves are allowed to be open for limited periods of time. The 31 day Frequency is consistent with other PCIV requirements discussed in SR 3.6.1.3.2.
SR 3.6.1.3.2 This SR verifies that each primary containment isolation manual valve and blind flange that is located outside primary containment and not locked, sealed, or otherwise secured and is required to be closed during accident conditions is closed. The SR helps to ensure that post accident leakage of radioactive fluids or gases outside the primary containment boundary is within design limits.
This SR does not require any testing or valve manipulation.
Rather, it involves verification that those PCIVs outside primary containment, and capable of being mispositioned, are in the correct position. Since verification of valve position for PCIVs outside primary containment is relatively easy, the 31 day Frequency was chosen to provide added assurance that the PCIVs are in the correct positions.
Two Notes have been added to this SR. The first Note allows valves and blind flanges located In high radiation areas to be verified by use of administrative controls. Allowing verification by administrative controls is considered acceptable since access to these areas is typically restricted during MODES 1, 2, and 3 for ALARA reasons. Therefore, the probability of misalignment of these PCIVs, once they have been verified to be in the proper position, is low. A second Note has been included to clarify that PCIVs that are open under administrative, controls are not required to meet the SR during the time that the PCIVs are open. This SR does not apply to valves that are locked, sealed, or otherwise secured in the closed position, since these were verified to be in the correct position upon locking, sealing, or securing.
SR 3.6.1.3.3 This SR verifies that each primary containment manual isolation valve and blind flange that is located inside (continued)
SUSQUEHANNA - UNIT 2 TS/B 3.6-24
'Revision I
PPL Rev. 3 PCIVs B 3.6.1.3 BASES SURVEILLANCE REQUIREMENTS S R 3.6.1.3.3 (continued) primary containment and not locked, sealed, or otherwise secured and is required to be closed during' accident conditions is closed.
The SR helps to ensure that post accident leakage of radioactive fluids or gases outside the primary containment boundary is within design limits. For PCIVs inside primary containment, the Frequency defined as "prior to entering MODE 2 or 3 from MODE 4 if primary containment was de-inerted while in MODE 4, if not performed within the previous 92 days" is appropriate since these PCIVs are operated under administrative controls and the probability of their misalignment is low. This SR does not apply to valves that are locked, sealed, or otherwise secured in the closed position, since these were verified to be in the correct position upon locking, sealing, or securing. Two Notes have been added to this SR. The first Note allows valves and blind flanges located in high radiation areas to be verified by use of administrative controls. Allowing verification by administrative controls is considered acceptable since the primary containment is inerted and access to these areas is typically restricted during MODES 1, 2, and 3 for ALARA reasons. Therefore, the probability of misalignment of these PCIVs, once they have been verified to be in their proper position, is low. A second Note has been included to clarify that PCIVs that are open under administrative controls are not required to meet the SR during the time that the.PCIVs are open.
SURVEILLANCE REQUIREMENTS SR 3.6.1.3.4 The traversing incore probe (TIP) shear isolation valves are actuated by explosive charges. Surveillance of explosive charge continuity provides assurance that TIP valves will actuate when required. Other administrative controls, such as those that limit the shelf life of the explosive charges, must be followed. The 31 day Frequency is based on operating experience that has demonstrated the reliability of the explosive charge continuity.
SR 3.6.1.3.5 Verifying the isolation time of each power operated and each automatic PCIV is within limits is required to demonstrate (continued)
SUSQUEHANNA - UNIT 2 TS / B 3.6-25 Revision 1
PPL Rev. 3 PCI Vs B 3.6.1.3 BASES SURVEILLANCE
'REQUIREMENTS S R 3.6.1.3.5 (continued),
OPERABILITY. MSIVs may be excluded from this SR since MSIV full closure isolation time is demonstrated by SR 3.6.1.3.7. The isolation time test ensures that the valve will isolate in a time period less than or equal to that assumed in the Final Safety Analyses Report. The isolation time and Frequency of this SR are in acc~ordance with the requirements of the Inservice Testing Program.
SR 3.6.1.3.6 For primary containment purge valves with resilient seals, the Appendix J Leakage Rate Test Interval of 24 months is sufficient.
The acceptance criteria for these valves is defined in the Primary Containment Leakage Rate Testing Program, 5.5.12.
The SR is modified by a Note stating that the primary containment purge valves are only required to meet leakage rate'testing requirements in MODES 1,2, and 3. If a LOCA inside primary containment occurs in these MODES, purge valve leakage must be minimized, to ensure offsite radiological release is within limits.
At other times when the purge valves are required to be capable of closing (e~g., during handling of irradiated fuel), pressurization concerns are not present and the purgevyalves are not required to meet any specific leakage criteria.
SR 3.6.1.3.7 Verifying that the isolation timre of each MSIV is Within the specified limits is required to demonstrate OPERABILITY. The isolation time test ensures that the MSIV~wilI isolate in a time period that does not exceed the times assumed in the DBA analyses. This enisures that the calculated radiological consequences of these events remain within 10 CFR 100 limits.
(continued)
SUSQUEHANNA - UNIT 2 TSIB3626Rvso TS / B 3.6-26 Revision 2
PPL Rev. 3 PCIVs B 3.6.1.3 BASES SURVEILLANCE SR 3.6.1.3.7 REQUIREMENTS (continued)
The Frequency of this SR is in accordance with the requirements of the Inservice Testing Program.
SR 3.6.1.3.8 Automatic PCIVs close on a primary containment isolation signal to prevent leakage of radioactive material from primary containment following a DBA. This SR ensures that each automatic PCIV will actuate to its isolation position on a primary containment isolation signal. The LOGIC SYSTEM FUNCTIONAL TEST in SR 3.3.6.1.5 overlaps this SR to provide complete testing of the safety function. The 24 month Frequency was developed considering it is prudent that some of these Surveillances be performed only during a unit outage since isolation of penetrations could eliminate cooling water flow and disrupt the normal operation of some critical components. Operating experience has shown that these components usually pass this Surveillance when performed at the 24 month Frequency. Therefore, the Frequency was concluded to be acceptable from a reliability standpoint SR 3.6.1.3.9 This SR requires a demonstration that a representative sample of reactor instrumentation line excess flow check valves (EFCV) are OPERABLE by verifying that the valve actuates to check flow on a simulated instrument line break. As defined in FSAR Section 6.2.4.3.5 (Reference 4), the conditions'under which an EFCV will isolate, simulated instrument line breaks are at flow rates which develop a differential pressure of between 3 psid and 10 psid.
This SR provides assurance that the instrumentation line EFCVs will perform its design function to check flow. No specific valve leakage limits are specified because no specific leakage limits are defined in the FSAR. The 24 month Frequency is based on the need to perform some of these Surveillances under the conditions that apply during a plant outage and the potential for an unplanned transient if the Surveillance were performed with the reactor at power.' The representative sample consists of an approximate equal number of EFCVs such that each EFCV is tested at least once every 10 years (nominal). The nominal 10 year interval is based on other performance-based testing programs, such as Inservice Testing (snubbers) and Option B to 10 CFR 50, Appendix J. In addition, the EFCVs in the sample are representative of the various plant configurations, models, sizes and operating environments. This ensures that any potential common problem with a specific type or application of EFCV is 1-
-1 I (continued)
SUSQUEHANNA - UNIT 2 TS / B3.627 Revision 3
PPL Rev. 3 PCIVs B 3.6.1.3 BASES SURVEILLANCE SR 3.6.1.3.9 (continued)
REQUIREMENTS detected at the earliest possible time. EFCV failures will be evaluated to determine if additional testing in that test interval is warranted to ensure overall reliability and that failures to isolate are very infrequent.
Therefore, testing of a representative sample was concluded to be acceptable from a reliability standpoint (Reference 7).
SR 3.6.1.3.10 The TIP shear isolation valves are actuated by explosive charges. An in Iplace functional test is not possible with this design. The explosive squib is removed and tested to provide assurance that the valves will actuate when required. The replacement charge for the explosive squib shall be from the same manufactured batch as the one fired or from another batch that has been certified by having one of the batch successfully fired. The Frequency of 24 months on a STAGGERED TEST BASIS is considered adequate given the administrative controls on replacement charges and the frequent checks of circuit continuity (SR 3.6.1.3.4).
SR 3.6.1.3.11 This SR ensures that the leakage rate of secondary containment bypass leakage paths is less than the specified leakage rate. -This provides assurance that the assumptions in the radiological evaluations of Reference 4 are met The secondary containment leakage pathways and Frequency are defined by the Primary Containment Leakage Rate Testing Program. This SR simply imposes additional acceptance criteria.
A note is added to this SR which states that these valves are only required to meet this leakage limit in MODES 1, 2, and 3. In the other MODES, the Reactor Coolant System is not pressurized and specific primary containment leakage limits are not required.
SR 3.6.1.3.12 The analyses in References I and 4 are based on the specified leakage rate. Leakage through each MSIV must be
- 100 scfh for anyone MSIV or
- 300 scfh for total leakage through the MSIVs combined with the Main Steam Line Drain Isolation Valve, HPCI Steam Supply Isolation Valve and
-..the RCIC Steam Supply Isolation Valve. The MSIVs can be tested at either > Pt (22.5 psig) or Pa (45 psig). Main Steam Line Drain Isolation, HPCI and RCIC Steam Supply Line Isolation Valves, are tested at Pa (45 psig). A note is added to this SR which states that these valves are only required to meet this leakage limit in MODES 1, 2, and 3. In the other (continued)
SUSQUEHANNA - UNIT 2 TS I B 3.6-28 Revision 6
PPL Rev. 3 PCIVs B 3.6.1.3 BASES SURVEILLANCE SR 3.6.1.3.12 (continued)
REQUIREMENTS conditions, the Reactor Coolant System is not pressurized and specific primary containment leakage limits are not required. The Frequency is required by the Primary Containment Leakage Rate Testing Program. If leakage from the MSIVs requires internal work on any MSIV, the leakage will be reduced for the affected MSIV to < 11.5 scfh.
SR 3.6.1.3.13 Surveillance of hydrostatically tested lines provides assurance that the calculation assumptions of Reference 2 are met. The acceptance criteria for the combined leakage of all hydrostatically tested lines is 3.3 gpm when tested at 1.1 Pa, (49.5 psig). The combined leakage rates must be demonstrated in accordance with the leakage rate test Frequency required by the Primary Containment Leakage Testing Program.
As noted in Table B 3.6.1.3-1, PCIVs associated with this SR are not Type C tested. Containment bypass leakage is prevented since the line-terminates below the minimum water level in the suppression chamber. These valves are tested in accordance with the IST Program. Therefore, these valves leakage is not included as containment leakage-This SR has been modified by a Note that states that these valves are only required to meet the combined leakage rate in MODES 1, 2, and 3, since this is when the Reactor Coolant System is pressurized and primary containment is required. In some instances, the valves are required to be capable of automatically closing during MODES other than MODES 1, 2, and 3. However, specific leakage limits are not applicable in these other MODES or conditions.
REFERENCES
- 1.
FSAR, Chapter 15.
- 2.
Final Policy Statement on Technical Specifications Improvements, July 22, 1993 (58 FR 39132).
- 3.
10 CFR 50, Appendix J, Option B.
- 4.
FSAR, Section 6.2.
- 5.
NEDO-30851-P-A, 'Technical Specification Improvement Analyses for BWR Reactor Protection System,"
March 1988.
-(continued)
SUSQUEHANNA - UNIT 2 TS/ B 3.6 Revision 3
PPL Rev. 3 PCIVs B 3.6.1.3 MACCC REFERENCES (continued)
- 6.
Standard Review Plan 6.2.4, Rev. 1, September 1975
- 7.
NEDO-32977-A, "Excess Flow Check Valve Testing Relaxation," June 2000 (continued)
SUSQUEHANNA - UNIT 2 -R TS I B 3.6-29a Revision 0
PPL Rev. 3 PCIVs B 3.6.1.3 Table B 3.6.1.3.1 Primary Containment Isolation Valve (Page 1 ofl1)
Isolation Signal LCO Valv Desripion ypeof Vlve 3.3.6.1 Function No.
Plant System Valve Number Valve Description Type of ValveIsolation E
Time (Seconds))
Containment 2-57-199 (d)
ILRT Manual N/A Atmospheri'c 2-57-200 (d)
ILRT Manual N/A Control HV-25703 Containment Purge Automatic Valve 2.b, 2.d, 2.e (15)
HV-25704 Containment Purge Automatic Valve 2.b, 2.d, 2.e (15)
HV-25705 Containment Purge Automatic Valve 2.b, 2A. 2.e (15)
HV-25711 Containment Purge Automatic Valve 2.b, 2.d. 2.e (15)
HV-25713 Containment Purge Automatic Valve 2.b, 2.d. 2.e (15)
HV-25714 Containment Purge Automatic Valve 2.b. 2.d. 2.e (15)
HV-25721 Containment Purge Automatic Valve 2.b, 2.d, Ze (15)
HV-25722 Containment Purge Automatic Valve 2.b, 2.d, 2.e (15)
HV-25723 Containment Purge Automatic Valve 2.b. 2.d, 2.e (15)
HV-25724 Containment Purge Automatic Valve 2.b, 2.d, 2.e (15)
HV-25725 Containment Purge Automatic Valve 2.b, 2.d, 2.e (15)
HV-25766 (a)
Suppression Pool Cleanup Automatic Valve 2.b. 2.d (35)
HV-25768 (a)
Suppression Pool Cleanup Automatic Valve 2.b, 2.d (30)
SV-2571 00 A Containment Radiation Detection Automatic Valve 2.b, 2.d, 2.f Syst SV-2571 00 B Containment Radiation Detection Automatic Valve 2.b, 2.d, 2.f
. Syst SV-2571 01 A Containment Radiation Detection Automatic Valve 2.b, 2.d, 2.f Syst SV-2571 01 B Containment Radiation Detection Automatic Valve *2b, 2.d, 2.f Syst SV-257102 A Containment Radiation Detection Automatic Valve 2.b, 2.d, 2.f Syst SV-257102 B Containment Radiation Detection Automatic Valve 2.b, 2.d, 2.f Syst RiiDttAo iVv 2,.
SV-2571034A Containment Radiation Detection Automatic Valve 2.b, 2.d, 2.f Syst SV-257103 B Containment Radiation Detection Automatic Valve 2.b, 2.d. 2.f SV-2571 04 Containment Radiation Detection Automatic Valve 2.b, 2.d, 2.f Syst SV-257105 Containment Radiation Detection Automatic Valve 2b. 2.d, 2.f Syst SV-2571 06 Containment Radiation Detection Automatic Valve 2b, 2.d, 2.f Syst SV-2571 07 Containment Radiation Detection Automatic Valve Zb, 2d, 2.f Syst
_____al Ata Vve b2 SV-25734 A (e)
Containment Atmosphere Sample Automatic Valve 2b, 2.d SV-25734 B (e)
Containment Atmosphere Sample Automatic Valve 2.b, 2d SV-25736 A (e)
Containment Atmosphere Sample Automatic Valve 2b, 2.d SV-25736 B (e)
Containment Atmosphere Sample Automatic Valve ab, Zd
________S-275-737 Nitrogen Makeup Automatic Valve Zb. 2.d, 2.e (wi),
SUSQUEHANNA - UNIT 2 TS / B 3.6-30.
.Revision 2
PPL Rev. 3 PCIVs B 3.6.1.3 Table B 3.6.1.3-1 Primary Containment Isolation Valve
_ _(
Page 2 of 10)
Isolation Signal LCO 3.3.6.1 Function No.
Plant System Valve Number Valve Description Type of Valve (Maximum Isolation Time (Seconds))
Containment SV-25738 Nitrogen Makeup Automatic Valve 2.b. 2.d, 2.e Atmospheric SV-25740 A (e)
Containment Atmosphere Sample Automatic Valve 2.b, 2.d Control SV-25740 B (e)
Containment Atmosphere Sample Automatic Valve 2.b, Zd (continued)
SV-25742 A (e)
Containment Atmosphere Sample Automatic Valve 2.b, 2.d SV-25742 B (e)
Containment Atmosphere Sample Automatic Valve 2.b, 2.d SV-25750 A (e)
Containment Atmosphere Sample Automatic Valve 2.b, 2.d SV-25750 B (e)
Containment Atmosphere Sample Automatic Valve 2.b, 2.d SV-25752 A (e)
Containment Atmosphere Sample Automatic Valve 2.b, Zd SV-25752 B (e)
Containment Atmosphere Sample Automatic Valve 2.b,2d -
SV-25767 Nitrogen Makeup Automatic Valve 2.b. 2d, 2.e SV-25774 A (e)
Containment Atmosphere Sample Automatic Valve 2.b. 2.d SV-25774 B (e)
Containment Atmosphere Sample Automatic Valve 2.b. Zd SV-25776 A (e)
Containment Atmosphere Sample Automatic Valve 2.b, 2.d SV-25776 B (e)
Containment Atmosphere Sample Automatic Valve 2.b, 2-d SV-25780 A (e)
Containment Atmosphere Sample Automatic Valve 2.b, 2d SV-25780 B (e)
Containment Atmosphere Sample Automatic Valve 2.b, 2.d SV-25782 A (e)
Containment Atmosphere Sample Automatic Valve 2.b, Zd SV-25782 B (e)
Containment Atmosphere Sample Automatic Valve 2.b, 2.d SV-25789 Nitrogen Makeup Automatic Valve.
2.b, 2d, Ze Containment 2-26-072 (d)
Containment Instrument Gas Manual Check N/A Instrument Gas 2-26-074 (d)
Containment Instrument Gas Manual Check-N/A.
2-26-152 (d)
Containment Instrument Gas Manual Check '-
N/A.
2-26-154 (d)
Containment Instrument Gas Manual Check N/A 2-26-164 (d)
Containment Instrument Gas Manual Check N/A HV-22603 Containment Instrument Gas Automatic Valve 2.c, Zd (20)
SV-22605 Containment Instrument Gas Automatic Valve 2.c, 2d SV-22651 Containment Instrument Gas Automatic Valve 2.c, 2d SV-22654 A Containment Instrument Gas.
Power Operated N/A SV-22654 B Containment Instrument Gas -
Power Operated N/A SV-22661 Containment Instrument Gas Automatic Valve 2.b, 2.d SV-22671 Containment Instrument Gas Automatic Valve 2.b, 2.d Core Spray HV-252F001 A (b)(c) ICS Suction Power ODerated N/A HV-252F001 B (b)(c) CS Suction Power Operated N/A HV-252F005 A CS Injection Power Operated N/A HV-252F005 B CS Injection Power Operated N/A HV-252F006 A CS Injection AOerate N/A
____Check Valve HV-252F006 B CS Injection Air Operated N/A C heck V alve_
HV-252F015 A (b)(c) CS Test Automatic Valve 2c, 2d (80)
WV-252F01 5 B (b)(c) CS Test Automatic Valve 2.c, 2d (80)
HV-252F.31 A (b)(c) CS Minimum Recirculation Flow Power Operated N/A HV-252F031 B (b)(c) CS Minimum Recirculation Flow Power Operated NIA SUSQUEHANNA - UNIT 2 TS I B 3.6-31 Revision 3
f 0
-PPL Rev. 3 PCI Vs f
.B 3.6.1.3 Table B 3.6.1.3-1 (continuedj Primary Containment Isolation Valve (Page 3 of 10) 0 Isolation Signal LCO Plant System
-Valve Number
-Valve Description Type of Valve 3.3..1iFnctin Nso.aio Time (Seconds))
Core Spray HV-252F037 A CS Injection Power Operated N/A (continued)
(Air)__
HV-252F037 B CS Injection Power Operated N/A XV-252F01SBA Core Spray Excess Flow N/A
- Check Valve I__
XV-252F018 B Core Spray -Excess Flow N/A C heck V alve Demin Water 2-41-017 (d)
Demineralized Water Manual N/A
________2-41-018 (d)
Demineralized Water XManual N/A HPCI 2-55-038 (d)
HPCI Injection Manual N/A 255F046 (b) (c) (d)
HPCI Minimum Recirculation Flow Manual Check N/A 255F049 (a) (d)
HPCI Manual Check N/A HV-255F002 HPCI Steam Supply Automatic Valve 3.a, 3.b, 3.c, 3.e, 3.f, 3.g. (5 0 )
HV-255F003 HPCI Steam Supply Automatic Valve 3.a, 3.b, 3.c, 3.e, 3.f, 3.g. (50)
HV-255F006 HPCI Injection Power Operated N/A HV-255F01 2 (b) (c)
HPCI Minimum Recirculation Flow Power Operated N/A HV-255F042 (b) (c)
HPCI Suction Automatic Valve 3.a, 3.b, 3.c, 3.e,3.f, 3.g, (90)
HV-255F066 (a)
HPCI Turbine Exhaust Power Operated N/A HV-255F075 HPCI Vacuum Breaker Automatic Valve 3.b, 3.d, (15)
HV-255F079 HPCI Vacuum Breaker Automatic Valve -
3.b. 3.d, (15)
HV-255F1 00 HPCI Steam Supply Automatic Valve 3.a, 3.b, 3.c, 3.e, 3.f, 3.g. (6)
XV-255F024 A HPCI
-Excess Flow.
N/
Check Valve XV-255F024 B HPCI Excess Flow N/A C heck V alve XVI-255F024 C HPCI Excess Flow N/A Check Valve XV-255F024 D HPCI Excess Flow N/A C heck V alve Liquid Radwaste HV-261 08 Al Liquid Radwaste Automatic Valve 2.b, 2.d (15)
Collecton HV-261 08 A2 Liquid Radwaste Automatic Valve 2.b, 2.d (15)
H-V-261 16 Al Liquid Radwaste Automatic Valve 2b, Z d (15)
-HV-261 16 A2 Liquid Radwaste Automatic Valve 2.b, Z d (15)
Nuclear Boiler 241 F01 0 A (d)
Feedwater Manual Check N/A 241 F01 0 B (d)
Feedwater Manual Check N/A 241 F039 A (d)
Feedwater Isolation Valve Manual Check
-N/A 241 F039 B (d)
Feedwater Isolation Valve Manual Check N/A 241818 A (d)
Feedwater Isolation Valve Manual Check N/A
________241818 B (d)
Feedwater Isolation Valve Manual Check N/A
-- SUSQUEHANNA - UNIT 2 TSIB3.6-32 Rvso
PPL Rev. 3 PCIVs B 3.6.1.3 Table B 3.6.1.3-1 (continued)
Primary Containment Isolation Valve (Page 4 of 10) w Isolation Signal LCO Plant System Valve Number Valve Description Type of Valve 3.3.6.1 Function No.
.(Maximum Isolation Time (Seconds))
Nuclear Boiler (continued)
HV-241 F01 6 MSL Drain Automatic Valve
-i.a, t.b, 1.c, 1.d, i.e (10)
HV-241 F01 9 MSL Drain Automatic Valve 1.a, 1.b, 1.c, 1.d, i.e
( 1 5 )
HV-241 F022 A MSIV Automatic Valve 1.a, 1.b, 1.c, 1.d, i.e
( 5 )
HV-241 F022 B MSIV Automatic Valve 1.a, 1.b, 1.c. 1.d, 1.e (5)
HV-241 F022 C MSIV Automatic Valve i.a, 1.b, 1.c, 1.d, 1.e (5)
HV-241 F022 D MSIV Automatic Valve 1.a, 1.b, 1.c, 1.d, i.e (5)
HV-241F028A MSIV Automatic Valve 1.a, 1.b, 1.c, 1.d, 1.e (5)
HV-241F028 B MSIV Automatic Valve 1.a, 1.b, 1.c, 1.d, I.e
( 5 )
HV-241 F028 C MSIV Automatic Valve i.a, 1.b, 1.c, 1.d, 1.e (5)
HV-241 F028 D MSIV Automatic Valve 1.a, 1.b, 1.c, 1.d, 1.e (5)
HV-241 F032 A Feedwater Isolation Valve Power Operated N/A Check Valves HV-241 F032 B Feedwater Isolation Valve Power Operated N/A Check Valves XV-24i1 F009 Nuclear Boiler EFCV Excess Flow N/A
- Check Valve XV-241 F070 A Nuclear Boiler EFCV Excess Flow N/A Check Valve XV-241 F070 B Nuclear Boiler EFCV Excess Flow N/A Check Valve XV-241 F070 C Nuclear Boiler EFCV Excess Flow NIA Check Valve XV-241 F070 D Nuclear Boiler EFCV Excess Flow N/A Check Valve XV-241 F071 A Nuclear Boiler EFCV Excess Ftow N/A Check Valve XV-241 F071 B Nuclear Boiler EFCV Excess Flow N/A Check Valve XV-241 F071 C Nuclear Boiler EFCV Excess Flow N/A Check Valve XV-241 F071 D Nuclear Boiler EFCV Excess Flow N/A Check Valve XV-241 F072 A Nuclear Boiler EFCV Excess Flow N/A Check Valve XV-241 F072 B Nuclear Boiler EFCV Excess Flow N/A i_
- Check Valve XV-241 F072 C Nuclear Boiler EFCV Excess Flow N/A Check Valve XV-241 F072 D Nuclear Boiler EFCV Excess Flow N/A Check Valve XV-241 F073 A Nuclear Boiler EFCV Excess Flow Check Valve NIA a
A A
- SUSQUEHANNA-UNIT 2 TS / B 3.6-33.
Revision 2
PPL Rev. 3 PCIVs B 3.6.1.3 Table B 3.6.1.341 (continued)
'Primary Containment Isolation Valve (Page 5 of 10)
Isolation Signal LCO Plant System Valve Number Valve Description Type of Valve 3.3.6.1 Function No.
(Maximum Isolation lTime (Seconds))
Nuclear Boiler XV-241 F073 B Nuclear Boiler EFCV Excess Flow N/A (continued)
Check Valve XV-241 F073 C Nuclear Boiler EFCV Excess Flow N/A
,Check Valve XV-241 F073 D Nuclear Boiler EFCV Excess Flow N/A
.Check Valve Nuclear Boiler XV-24201 Nuclear Boiler Vessel Instrument Excess Flow N/A Vessel Check Valve Instrumentation XV-24202 Nuclear Boiler Vessel Instrument Excess Flow N/A
.Check Valve XV-242F041 Nuclear Boiler Vessel Instrument Excess Flow N/A Check Valve XV-242F043 A Nuclear Boiler Vessel Instrument Excess Flow N/A X
Check Valve XV-242F043 B Nuclear Boiler Vessel Instrument Excess Flow N/A Check Valve.
XV-242F045 A Nuclear Boiler Vessel Instrument Excess Flow N/A
.Check Valve XV-242F045 B Nuclear Boiler Vessel Instrument Excess Flow N/A
.Check Valve XV-242F047 A Nuclear Boiler Vessel Instrument Excess Flow N/A
.Check Valve XV-242F047B Nuclear Boiler Vessel Instrument Excess Flow N/A
.Check Valve XV-242F051 A Nuclear Boiler Vessel Instrument Excess Flow N/A
.Check Valve XV-242F051 B Nuclear Boiler Vessel Instrument
-Excess Flow
- N/A V __
._._-_._._Check Valve XV-242F051 C Nuclear Boiler Vessel Instrument Excess Flow NIA
. __._._--_-_._:_Check Valve XV-242F051 D Nuclear Boiler Vessel Instrument Excess Flow N/A Check Valve L
XV-242F053 A Nuclear Boiler Vessel Instrument Excess Flow N/A
._Check Valve XV-242F053 B Nuclear Boiler Vessel Instrument Excess Flow N/A
=Check Virve XV-242F053 C Nuclear Boiler Vessel Instrument Excess Flow N/A
_.__._.__:_Check Valve XV-242F053 D Nuclear Boiler Vessel Instrument Excess Flow N/A Check Valve XV-242F055 Nuclear Boiler Vessel Instrument Excess Flow, N/A
_-__.__Check Valve XV-242F057 Nuclear Boiler Vessel Instrument Excess Flow N/A Check Valve XV-242F059 A Nuclear Boiler Vessel Instrument Excess Flow N/A Check Valve XV-242F059 B Nuclear Boiler Vessel Instrument Excess Flow N/A
.Check Valve SUSQUEHANNA - UNIT 2 TS / B 3.6-34 Revision I
PPL Rev. 3 PCIVs B 3.6.1.3 Table B 3.6.1.3-1 Primary Containment Isolation Valve
.(Page 6 of 10)
Isolation Signal LCO Plant System Valve Number Valve Description Type of Valve 3M.x1munction (Maximum Isolation Time (Seconds))
Nuclear Boiler XV-242F059 C Nuclear Boiler Vessel Instrument Excess Flow N/A Vessel Check Valve Instrumentation XV-242F059 D Nuclear Boiler Vessel Instrument Excess Flow N/A (continued)
Check Valve XV-242F059 E Nuclear Boiler Vessel Instrument Excess Flow N/A Check Valve XV-242F059 F Nuclear Boiler Vessel Instrument Excess Flow N/A Check Valve XV-242F059 G Nuclear Boiler Vessel Instrument Excess Flow N/A Check Valve XV-242F059 H Nuclear Boiler Vessel Instrument Excess Flow N/A Check Valve XV-242F059 L Nuclear Boiler Vessel Instrument Excess Flow N/A L_
Check Valve XV-242F059 M Nuclear Boiler Vessel Instrument Excess Flow N/A Check Valve XV-242F059 N Nuclear Boiler Vessel Instrument Excess Flow N/A Check Valve XV-242F059 P Nuclear Boiler Vessel Instrument Excess Flow N/A Check Valve XV-242F059 R Nuclear Boiler Vessel Instrument Excess Flow N/A Check Valve XV-242F059 S Nuclear Boiler Vessel Instrument Excess Flow N/A
- __.Check Valve XV-242F059 T Nuclear Boiler Vessel Instrument Excess Flow N/A Check Valve.
XV-242F059 U Nuclear Boiler Vessel Instrument Excess Flow N/A Check Valve XV-242F061 Nuclear Boiler Vessel Instrument Excess Flow N/A Check Valve RB Chilled Water HV-28781 Al RB Chilled Water Automatic Valve 2.c, 2.d (40)
System HV-28781 A2 RB Chilled Water Automatic Valve 2.c, 2.d (40)
HV-28781 B1 RB Chilled Water Automatic Valve 2.c, Zd (40)
HV-28781 B2 RB Chilled Water Automatic Valve 2.c, 2.d (40)
HV-28782 Al
-RB Chilled Water Automatic Valve 2c, 2.d (12)
HV-28782 A2 RB Chilled Water Automatic Valve 2c, 2.d (12)
HV-28782 Bi RB Chilled Water Automatic Valve 2c, 2.d (12)
HV-28782 B2.
RB Chilled Water Automatic Valve
-2c, 2.d (12)
HV-28791 Al
-RB Chilled Water Automatic Valve Ze, 2.d (15)
HV-28791 A2 RB Chilled Water Automatic Valve Zc, Zd (15)
HV-28791 B1 RB Chilled Water Automatic Valve 2.c, 2.d (15)
HV-28791 B2 RB Chilled Water Automatic Valve 2.c, 2.d (15)
HV-28792 Al RB Chilled Water Automatic Valve 2.c 2.d (8)
HV-28792 A2 RB Chilled Water Automatic Valve 2c, 2.d (8)
HV-28792 B1 RB Chilled Water Automatic Valve 2 c, 2.d (8)
SUSQUEHANNA - UNIT 2 TS / B3.6-35 Revision 2
PPL Rev. 3 PCIVs B 3.6.1.3 I W)
_Table B 3.6.1.3-1 Primary Containment Isolation Valve (Page 7 of 10)
Isolation Signal LCO Plant System Valve Number Valve Description Type of Valve (Maximum Isolation Time (Seconds))
RB Chilled Water HV-28792 B2 RB Chilled Water Automatic Valve 2.b, 2.d (8)
System (continued)
RBCCW HV-21313 RBCCW Automatic Valve 2.c, 2.d (30)
HV-21314 RBCCW Automatic Valve 2.c, 2.d (30)
HV-21345 RBCCW Automatic Valve 2.c, 2.d (30)
HV-21346 RBCCW Automatic Valve 2.c, 2.d (30)
RCIC 2-49-020 (d)
RCIC Injection Manual N/A 249F021 (b) (c) (d)
RCIC Minimum Recirculation Flow Manual Check N/A 249F028 (a) (d)
RCIC Vacuum Pump Discharge Manual N/A 249F040 (a) (d)
RCIC Turbine Exhaust Manual NIA FV-249F019 (b) (c)
RCIC Minimum Recirculation Flow Power Operated N/A HV-249F007 RCIC Steam Supply Automatic Valve 4.a, 4.b, 4.c, 4.e, 4.f, 4.g (20)
HV-249F008 RCIC Steam Supply Automatic Valve 4.a, 4.b, 4.c, 4.e, 4.f,
.4.g (20)
HV-249F013 RCIC Injection Power Operated N/A HV-249F031 (b) (c)
RCIC Suction Power Operated N/A HV-249F059 (a)
RCIC Turbine Exhaust Power Operated N/A HV-249F060 (a)
RCIC Vacuum Pump Discharge Power Operated N/A HV-249F062 ROIC Vacuum Breaker Automatic Valve 4.b, 4.d (10)
HV-249F084 RCIC Vacuum Breaker Automatic Valve 4.b, 4.d (10)
HV-249F088 RCIC Steam Supply Automatic Valve 4.a, 4.b, 4.c, 4.e, 4.f.
4.g(12)
XV-249F044 A RCIC Excess Flow N/A
-Check Valve -
XV-249F044 B RCIC Excess Flow
- N/A Check Valve XV-249F044 C RCIC Excess Flow N/A Check Valve XV-249F044 D RCIC Excess Flow N/A Check Valve Reactor 243F013 A (d)
Recirculation Pump Seal Water Manual Check N/A Recirculation 243F013 B (d)
Recirculation Pump Seal Water Manual Check N/A HV-243F019 Reactor Coolant Sample Automatic Valve 2.b (9)
HV-243F020 Reactor Coolant Sample Automatic Valve 2.b (2)
XV-243F003 A Reactor Recirculation Excess Flow N/A Check Valve XV-243F003 B Reactor Recirculation Excess Flow WNA Check Valve XV-243F004 A Reactor Recirculation Excess Flow N/A Check Valve XV-243F004 B Reactor Recirculation Excess Flow N/A
- Check Valve SUSQUEHANNA - UNIT 2 I TS / B 3.6-36 Revision 2 i.
I 1- -
PPL Rev. 3 PCIVs B 3.6.1.3 Table B 3.6.1.3-4 Primary Containment Isolation Valve (Page 8 of1O ) -._,_._._:
.Isolation Signal LCO Number3Te (MaxiumncotionNo Plant System Valve Number Valve Description Type of Valve 3..61muncion N
-Time (Seconds))
Reactor Recirculation
.(continued)
XV-243F009 A Reactor Recirculation Excess Flow Check Valve NIA XV-243F009 B Reactor Recirculation Excess Flow N/A
.Check Valve XV-243F009 C Reactor Recirculation Excess Flow N/A Check Valve XV-243F009 D Reactor Recirculation Excess Flow N/A Check Valve XV-243F010 A Reactor Recirculation Excess Flow N/A Check Valve XV-243F010 B Reactor Recirculation Excess Flow N/A Check Valve XV-243F010 C Reactor Recirculation Excess Flow, N/A-Check Valve XV-243F010 D Reactor Recirculation Excess Flow N/A Check Valve XV-243F01 I A Reactor Recirculation Excess Flow N/A Check Valve XV-243F011 B Reactor Recirculation Excess Flow NIA
._ Check Valve XV-243F011 C Reactor Recirculation Excess Flow N/A Check Valve XV-243F011 D Reactor Recirculation Excess Flow N/A
.Check Valve XV-243F012A Reactor Recirculation Excess Flow N/A
-Check Valve.
XV-243F012 B Reactor Recirculation Excess Flow N/A Check Valve XV-243F012 C Reactor Recirculation Excess Flow N/A
'Check Valve XV-243F01 2 D Reactor Recirculation Excess Flow N/A
. Check Valve XV-243F017 A Recirculation Pump Seal Water Excess Flow N/A Check Valve XV-243F0177 5 Recirculation Pump Seal Water Excess Flow N/A
.Check Valve XV-243F040 A Reactor Recirculation Excess Flow N/A
.Check Valve XV-243F040 B Reactor Recirculation Excess Flow N/A
- _ _Check Valve XV-243F040 C Reactor Recirculation Excess Flow N/A
.Check Valve XV-243F040 D Reactor Recirculation Excess Flow N/A Check Valve XV-243F057 A Reactor Recirculation Excess Flow N/A Check Valve I
XV-243F057 B Reactor Recirculation Excess Flow Check Valve N/A Residual Heat HV-251 F004 A (b) (c)
RHR - Suppression Pool Suction [ Power Operated I N/A Removal
[HV-251 F004 B (b) (c)
RHR - Suppression Pool Suction Power Operated N/A I HV-251 F004 C (b) (c)
RHR - Suppression Pool Suction Power Operated N/A SUSQUEHANNA - UNIT 2 TS I B 3.6-37 Revision 2
PPL Rev. 3 PCIVs B 3.6.1.3 Table B 3.6.1.3-1 (continued)
Primary Containment Isolation Valve (Page 9 of 10)
Isolation Signal LCO 3.3.6.1 Function No.
Plant System Valve Number Valve Description Type of Valve (Maximu Isotion (Maximum Isolation Time (Seconds))
Residual Heat HV-251 F004 D(b) (c)
RHR - Suppression Pool Suction Power Operated N/A Removal HV-251 F007 A (b) (c)
RHR - Minimum Recirculation Power Operated N/A (continued)
HV-251 F007 B (b) (c)
RHR - Minimum Recirculation Power Operated N/A HV-251 F008 RHR - Shutdown Cooling Suction Automatic Valve 6.a, 6.b, 6.c (52)
HV-251 F009 RHR - Shutdown Cooling Suction Automatic Valve 6.a, 6.b, 6.c (52)
HV-251 F011 A (b) (d)
RHR - Suppression Pool Cooling Manual N/A HV-251 F011 B (b) (d)
RHR - Suppression Pool Cooling Manual N/A HV-251 F015 A RHR - Shutdown Cooling Power Operated NIA Return/LPCI Injection HV-251 F015 B RHR - Shutdown Cooling Power Operated NIA Return/LPCI Injection HV-251 F016 A (b)
RHR - Drywell Spray Automatic Valve 2.c, 2.d (90)
HV-251 F01 6 B (b)
RHR - Drywell Spray Automatic Valve 2.c, 2.d (90)
HV-251 F022 RHR - Reactor Vessel Head Spray Automatic Valve 2.d. 6.a, 6.b. 6.c (30)
HV-251 F023 RHR - Reactor Vessel Head Spray Automatic Valve 2.d, 6.a, 6.b, 6.c (20)
HV-251 F028 A (b)
RHR - Suppression Pool Automatic Valve 2.c, 2.d (90)
Cooling/Spray HV-251 F028 B (b)
RHR - Suppression Pool Automatic Valve 2.c, 2.d (90)
Cooling/Spray HV-251 F050 A RHR - Shutdown Cooling Air Operated N/A ReturnlLPCI Injection Check Valve HV-251 F050 B RHR - Shutdown Cooling Air Operated N/A Retum/LPCI Injection Check Valve HV-251 F1 03 A (b)
RHR Heat-Exchanger Vent Power Operated -
NIA HV-251 F1 03 B (b)
RHR Heat Exchanger Vent Power Operated N/A HV-251 F1 22 A RHR - Shutdown Cooling
-Power Operated NIA Return/LPCI Injection (Air)
HV-251 F1 22 B RHR - Shutdown Cooling Power Operated N/A Retum/LPCI Injection (Air)
PSV-25106 A (b) (d)
RHR-Relief Valve Discharge Relief Valve N/A PSV-25106 B (b) (d)
RHR-Relief Valve Discharge -
Relief Valve N/A PSV-251 F1 26 (d)
RHR-Shutdown Cooling Suction Relief Valve N/A XV-25109A RHR Excess Flow N/A Check Valve XV-25109 B RHR Excess Flow N/A Check Valve XV-25109 C RHR Excess Flow N/A Check Valve XV-25109 D RHR Excess Flow N/A Check Valve RWCU HV-244F001 (a)
RWCU Suction Automatic Valve 5.a. 5.b, 5.c, 5.d. 5.f,
_ _ _5
.g (3 0 )
(qw,
SUSQUEHANNA - UNIT 2 ITS / B 3.6-38 Revision 1'
PPL Rev. 3 PCIVs B 3.6.1.3 Table B 3.6.1.3-1 Primary Containment Isolation Valve
_(Pagel ofIO)
Isolation Signal LCO PlantTypeematlvValveer3.3.6.1 Function No.
Plant System Valve Number Valve Description Type of Valve Maxiu Isolaon Time (Seconds))
RWCU HV-244F004 (a)
RWCU Suction Automatic Valve 5.a, 5.b, 5.c, 5.d, 5.e, (continued)
-____-_5.f.
5.g (30)
XV-24411 A RWCU Excess Flow N/A Check Valve XV-24411 B RWCU Excess Flow N/A
<L_
Check Valve XV-24411 C RWCU Excess Flow N/A Check Valve XV-24411 D RWCU Excess Flow N/A Check Valve XV-244F046 RWCU Excess Flow NIA Check Valve HV-24182 A RWCU Return Power Operated N/A HV-24182 B RWCU Return Power Operated N/A SLCS 248F007 (a) (d)
SLCS Manual Check N/A HV-248F006 (a)
SLCS Power Operated N/A Check Valve TIP System C51-JV04A(Balle TIP Ball Valves Automatic Valve 7.a, 7.b (5)
Valve)
C51-J004 B (Ball TIP Ball Valves Automatic Valve 7.a, 7.b (5)
Valve)
TIPBallValves
_AutomaicValve_.__________(5 C51-J004 C (Ball TIP Ball Valves Automatic Valve 7.a, 7.b (5)
Valve)__
C51-J004 D (Ball TIP Ball Valves Automatic Valve 7.a. 7.b (5)
Valve)
C51-J004 E (Ball TIP Ball Valves
-Automatic Valve 7.a, 7.b (5)
Valve)
TIP System C51VJv04 A (Shear TIP Shear Valves Squib Valve NMA (continued)
Valve)
C51-J004 B (Shear TIP Shear Valves Squib Valve N/A Valve)
C(s-Jo04 C (Shear TIP Shear Valves Squib Valve N/A V alve)
C51-J004 D (Shear TIP Shear Valves Squib Valve N/A Valve)
C51-J004 E (Shear TIP Shear Valves qubVle N/A V alve)__
(a)
Isolation barrier remains filled or a water seal remains in the line post-LOCA, isolation valve is tested with water.
Isolation valve leakage is not included in 0.60 L. total Type B and C tests.
(b)
Redundant isolation boundary for this valve is provided by the closed system whose integrity is verified by the Leakage Rate Test Program. This footnote does not apply to valve 255F046 (HPCI) when the associated PCIV, HV255F01 2 is closed and deactivated. Similarly, this footnote does not apply to valve 249F021 (RCIC) when it's associated PCIV, FV249F019 is closed and deactivated.
(c)
Containment Isolation Valves are not Type C tested. Containment bypass leakage is prevented since the line terminates below the minimum water level in the Suppression Chamber. Refer to the IST Program.
(d)
LCO 3.3.3.1, 'PAM Instrumentation, Table 3.3.3.1-1, Function 6, (PCIV Position) does not apply since these are relief valves, check valves, manual valves or deactivated and closed.
(e)
The containment isolation barriers for the penetration associated with this valve consists of two PCIVs and a closed system. The closed system provides a redundant isolation boundary for both PCIVs, and its integrity is required to be verified by the Leakage Rate Test Program.
I SUSQUEHANNA - UNIT 2 TS / B 3.6-39 Revision 5