AmerGen SM AmerGen Energy Company, LLC 200 Exelon Way Kennett Square, PA 19348 www.exeloncorp.com An Exelon Company 1 OCFR50.46 June 1, 2004 5928-04-20128 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555-0001 Three Mile Island, Unit 1 (TMI Unit 1)
Operating License No. DPR-50 Docket No.50-289
Subject:
10 CFR 50.46 Annual Report
References:
- 1.
FANP Topical Report BAW-10104P-A, Rev. 5, "B&W's ECCS Evaluation Model," November 1988.
- 2.
FANP Topical Report BAW-1 0154-A, Rev. 0, "B&W's Small-Break LOCA ECCS Evaluation Model," July 1985.
- 3.
FANP Topical Report BAW-10192P-A, Rev. 0,"BWNT LOCA - BWNT Loss-of-Coolant Accident Evaluation Model for Once-Through Steam Generator Plants," June 1998.
10 CFR 50.46 (a)(3)(ii) states that each holder of an operating license shall report to the Nuclear Regulatory Commission (NRC) at least annually each change or error in an accepted emergency core cooling system (ECCS) evaluation model (EM) Cr in the application of such a model that affects the peak cladding temperature (PCT) calculation.
For the repcrting period from January 1, 2003 through December 31, 2003, AREVA (formally Framatome ANP) has confirmed that no significant errors were reported in the CRAFT2-based B&W ECCS EM (Reference 1 for LBLOCA and Reference 2 for SBLOCA). One change and one application error correction are reported in the RELAP5/MOD2-B&W-based BWNT LOCA EM (Reference 3) as described in Enclosure 1. Enclosure 2 provides a summary of the EM changes applicable to TMI Unit 1 as identified and evaluated by AREVA, and reported in accordance with 10 CFR 50.46(a)(3)(ii).
No new regulatory commitments are established in this submittal.
AP-01 I,
5928-04-20128 June 1, 2004 Page 2 If any additional information is needed, please contact David J. Distel at (610) 765-5517.
Very truly yours, Michael P. Gallagher Director - Licensing & Regulatory Affairs AmerGen Energy Company, LLC
Enclosures:
- 1) EM Changes and Significant Error Notification
- 2) Summary of EM Changes Applicable to TMI Unit 1 cc: H. J. Miller, USNRC Administrator, Region I D. M. Skay, USNRC Senior Project Manager, TMI Unit 1 D. M. Kern, USNRC Senior Resident Inspector, TMI Unit 1 File No. 00068
ENCLOSURE 1 EM CHANGES AND SIGNIFICANT ERROR NOTIFICATION 1.1 CRAFT2 Evaluation Model Error Corrections or Changes No errors or changes were reported in the CRAFT2-based B&W ECCS EM, BAW-1 01 04P-A, Rev. 5 for LBLOCA (Reference 1.1) and BAW-10154-A, Rev. 0 for SBLOCA (Reference 1.2),
during 2003.
1.2 BWNT LOCA Evaluation Model Error Correction or Changes This evaluation model (EM) is applicable to all B&W-designed pressurized water reactors for large and small break LOCA analyses for zircaloy or M5 cladding. The NRC-approved topical report for this EM is BAW-101 92P-A Rev 0 (Reference 1.3).
The large break LOCA Evaluation Model consists of four computer codes:
- 1.
BAW-10164P-A, RELAP5/MOD2-B&W to compute the system, core, and hot rod response during blowdown (Reference 1.4),
- 2.
BAW-10171 P-A, REFLOD3B to calculate the time for refill of the lower plenum and core reflood rate (Reference 1.5),
- 3.
BAW-1 0095-A, CONTEMPT to compute the containment pressure response (Reference 1.7), and
- 4.
BAW-10166P-A, BEACH (the RELAP5/MOD2-B&W reflood heat transfer package) to determine the hot pin thermal response during refill and reflood phases (Reference 1.6 and Reference 1.11).
The small break LOCA Evaluation Model consists of two codes:
- 1.
BAW-10164P-A, RELAP5/MOD2-B&W to compute the system, core, and hot rod response during the transient (Reference 1.4), and
- 2.
BAW-10095-A, CONTEMPT to compute the containment pressure response (Reference 1.7), if needed.
An NRC-approved fuel code (currently BAW-10162P-A, TACO3 (Reference 1.9) or BAW-10184P-A, GDTACO (Reference 1.10)) is used to supply the fuel rod steady-state conditions at the beginning of the small or large break LOCA. These codes are approved for use with M5 cladding as discussed in BAW-1 0227P-A (Reference 1.8).
It should be noted that the most recently approved versions of the EM and associated topical reports are referenced above. However, the plant-and fuel-type-specific licensing calculations may be based on an earlier approved method and thus not specifically utilize the enhanced features that were subsequently approved or submitted as a change via 10 CFR 50.46. A summary of the intermediate EM changes and EM error corrections made to BAW-1 01 92P-A is discussed in Section 1.4 and listed in Enclosure 1, Table 1.
One EM change in the RELAP5/MOD2-B&W-based BWNT LOCA EM occurred during 2003.
5928-04-20128 Page 2 of 7 1.2.1 Change of RELAP5/MOD2-B&W for Mark-B-HTP Fuel The BHTP CHF correlation from BAW-1 0241 P (BHTP DNB Correlation Applied with LYNXT, Reference 1.15) was implemented into the RELAP51MOD2-B&W code for analysis of Mark-B-HTP fuel. This change was made to support the EM requirement in Section 4.3.4.8 of Volume 1 of BAW-10192P-A, which states that the LOCA analyses will use the same CHF correlation that is used for the fuel pin DNB analyses. The BHTP DNB correlation used in the LOCA analyses sets the non-uniform axial power distribution factor to unity, which is similar to the method used for defining the Tong factor used in the existing approved CHF correlations.
The BHTP correlation ranges for transition to the low-flow or low-pressure CHF correlations were extended consistently with the methods used during implementation of the existing approved CHF correlations. The implementation is described in Reference 1.16.
The Mark-B-HTP design is not currently used at Three Mile Island Unit 1. A PCT change is not applicable to non-Mark-B-HTP fuel assemblies because introduction of this correlation does not affect the temperature calculation for those analyses.
1.3 Error Correction for Containment Pressure Input for 177-FA Lowered-Loo, LBLOCA Analyses An error was discovered in the input of the mass and energy data input to the CONTEMPT model. The error originates from allowing the CONTEMPT code to linearly interpolate in the mass and energy data that was generated over distinct time intervals. The result is that the CONTEMPT integrated mass and energy release is not consistent with the system analyses, and the LOCA containment pressure response is overpredicted. Reference 1.12 summarizes the effect of correcting the mass and energy input to certain CONTEMPT analyses that define the containment pressure input to LBLOCA analyses for the 177-FA lowered-loop analyses performed prior to 2003. The correction of this error results in a reduction of the containment pressure. A characteristic of LOCA analyses for the lowered-loop plant design is that the LBLOCA PCT tends to occur just after the end of the adiabatic heat-up period. Lowering the containment pressure increases the CFT injection flow during the refill period, which shortens the adiabatic heat-up period and reduces the PCT. This application error was reported as AREVA Nonconformance Report 6027345 (Reference 1.13) for ANO-1, TMI-1 and ONS and in AREVA Nonconformance Report 6027344 (Reference 1.14) for CR-3.
This issue is considered an Application Error Correction. The PCT change associated with this Application Error Correction for TMI Unit 1 is reported in Enclosure 2.
1.4 Generic EM Information General information related to the EM topical reports and associated modeling guidance is provided below. These topics do not constitute EM changes or error corrections, and are provided as information.
1.4.1 Approval of BEACH Topical Report Revision AREVA previously submitted a revision to the BEACH topical report for large break analyses to extend (i) the range of application for the maximum cladding temperature limit to 2045 F for BEACH, (ii) the minimum reflood rate to 0.4 in/sec, and (iii) the minimum applicable containment pressure to 14.7 psia. The extension of the cladding temperature limit to 2045 F 5928-04-20128 Page 3 of 7 was previously reported via 10 CFR 50.46 reporting for 1999 and as an EM Error Correction in 2001. The NRC, by letter dated November 7, 2003 (Reference 1.11), approved Revision 5 of the BEACH topical report, BAW-10166P, and its use with the once-through steam generator large break and small break LOCA evaluation models, BAW-10192P-A.
1.4.2 Approval of Reactor Coolant Pump Degradation Model Change for RELAP5/MOD2-B&W Preliminary Safety Concern 2-00 (Reference 1.27) investigated SBLOCAs with reactor coolant pump (RCP) operation beyond the time of turbine trip. It was discovered that more severe consequences could be predicted for larger SBLOCAs when the RCPs were manually tripped at one to two minutes following loss-of-subcooling margin, and that these consequences were even worse when the M3-modified RCP degradation model (lower bound providing least pump degradation) was applied. The NRC, by letter dated April 10, 2003 (Reference 1.17), approved the use of the M3-modified two-phase reactor coolant pump degradation multiplier in RELAP5/MOD2-B&W for resolution of PSC 2-00. This approval is contingent upon each licensee establishing that the M3-modified curve is conservative for each licensee's plant.
AREVA has prepared generic material to justify the use of the M3-modified curve with respect to the plant-specific reactor coolant pumps. This material is currently being reviewed and prepared for submittal to the NRC. Use of the M3-modified RCP degradation multiplier was previously applied as an EM Change in 2000 and 2001.
1.4.3 Change to RELAP5/MOD2-B&W Evaluation Model Guidance Documents Several ancillary guidance documents that supplement BAW-10192P-A and the code topical reports were created or updated in 2003 to facilitate the uniform application of the approved methods. They make no changes to the approved methods used to perform licensing calculations.
Limitations and Restrictions on BAW-10192P-A (Reference 1.18). This guidance document outlines the NRC limitations and restrictions imposed on BAW-1 01 92 and the associated code topical reports. The document was revised to include recent NRC approvals.
RELAP5 Modeling Guidelines (Reference 1.19). This guidance document outlines generic RELAP5/MOD2-B&W modeling practices and was revised to incorporate more detailed information and recent NRC approvals.
CONTEMPT Modeling Guidelines (Reference 1.20). This guidance document outlines generic CONTEMPT modeling practices for use in.LOCA containment pressure calculations.
TACO3/GDTACO Output Guidelines (References 1.21 and 1.22). These documents describe the conversion of the output from the TACO3 and GDTACO3 steady-state fuel initialization cases to input to the RELAP5/MOD2-B&W code.
REFLOD3B Methods (Reference 1.26). This document reviews the history of the various REFLOD3B models utilized in B&W plant licensing calculations and identified categories of REFLOD3B input parameters to facilitate updating of future models.
REFLOD3B Output Guidelines (References 1.23, 1.24 and 1.25). These documents describe the conversion of the output from the REFLOD3B code to input to the BEACH code.
5928-04-20128 Page 4 of 7 1.4.4 Outline of Evolution of BAW-10192P-A Changes The general outline for application of the Evaluation Model is described in BAW-10192P-A. The code topical report revisions identified in BAW-10192P-A Rev. 0 for use in LOCA analyses are:
BAW-10164P-A, Revision 3, RELAP5/MOD2-B&W, BAW-10171 P-A, Revision 3, REFLOD3B, BAW-10166P-A, Revision 4, BEACH, BAW-10095-A, Revision 1, CONTEMPT, and BAW-1 01 62P-A, Revision 0, TACO3.
Since the approval of BAW-1 01 92P-A, the codes and methods have evolved through approved code revisions, identification of specific codes not identified in the EM, and the addition of new methods and error corrections made under 10 CFR 50.46. The following NRC-approved topical reports have been added as part of the EM. However, these revisions are not explicitly identified in BAW-10192P-A Rev. 0.
BAW-10164P-A, Revision 4, RELAP5/MOD2-B&W BAW-1 01 66P-A, Revision 5, BEACH BAW-10227P-A, Revision 0, M5 Cladding BAW-10184P-A, Revision 0, GDTACO The addition of new methods and error corrections made under 10 CFR 50.46 are reported to the utilities at least annually for including in plant-specific 10 CFR 50.46 reports to the NRC.
In the case of new methods, acceptable licensing cases are typically not reanalyzed or reevaluated in order to take advantage of the new methods. (Error corrections are applied to current licensing basis cases as necessary.) Therefore, the last acceptable licensing cases for a specific plant may not have been performed with the most recent EM changes (approved or made via 10 CFR 50.46). In order to assist the utility in identifying which EM and 10 CFR 50.46 changes were utilized in their licensing cases, Table 1 was created. The different stages of models available via reference to BAW-10192P-A are identified in Table 1 as versions by denoted by "RN.n", where "R" stands for revision, "N" represents the revision of BAW-10192P-A (in all cases, 0) and "n" is the subrevision identifier of the modeling change not explicitly described in the NRC-approved Revision of BAW-10192P-A. These informal revision levels are for internal tracking purposes in order to identify those EM and 10 CFR 50.46 changes that are applied in the analyses. The revision level is reported in the plant-specific PCT summary tables alongside the final licensing PCT.
5928-04-20128 Page 5 of 7 References 1.1 AREVA Topical Report BAW-10104P-A, Rev. 5, "B&W's ECCS Evaluation Model," November 1988.
1.2 AREVA Topical Report BAW-1 0154-A, Rev. 0, "B&W's Small-Break LOCA ECCS Evaluation Model," July 1985.
1.3 AREVA Topical Report BAW-10192P-A, Rev. 0, "BWNT LOCA - BWNT Loss-of-Coolant Accident Evaluation Model for Once-Through Steam Generator Plants," June 1998.
1.4 AREVA Topical Report BAW-1 01 64P-A, Rev. 4, "RELAP5/MOD2-B&W - An Advanced Computer Program for Light Water Reactor LOCA and Non-LOCA Transient Analysis",
November 2002.
1.5 AREVA Topical Report BAW-1 0171 P-A, Rev. 3, "REFLOD3B - Model for Multinode Core Reflooding Analysis", December 1995.
1.6 AREVA Topical BAW-10166P, Rev. 5, "BEACH - A Computer Program for Reflood Heat Transfer During LOCA", December 2001.
1.7 AREVA Topical Report BAW-1 0095-A, Rev. 1, "CONTEMPT-Computer Program for Predicting Containment Pressure-Temperature Response to a LOCA", April 1978.
1.8 AREVA Topical Report BAW-1 0227P-A, Rev. 1, "Evaluation of Advanced Cladding and Structural Material (M5) in PWR Reactor Fuel", June 2003.
1.9 AREVA Topical Report BAW-1 01 62P-A, Rev. 0, `TACO3 Fuel Pin Thermal Analysis Code",
October 1989.
1.10 AREVA Topical Report BAW-1 01 84P-A, Rev. 0, "GDTACO Urania - Gadolinia Fuel Pin Thermal Analysis Code", February 1995.
1.11 Letter dated 11/7/03 from H. N. Berkow USNRC to J. F. Mallay (Areva), "Issuance of Revised Safety Evaluation for Referencing of Appendices H and I to BAW-10166P-A, "BEACH - Best Estimate Analysis Core Heat Transfer, A Computer Program for Reflood Heat Transfer During LOCA", (TAC No. MC0341)", USNRC ADAMS Accession Number ML033140275.
1.12 AREVA Proprietary Document 51-5031991-00, "Resolution of NCR 6027345, CONTEMPT M&E Input", 10/7/03.
1.13 AREVA Document T5.16-6027345-00, (CONTEMPT LOCA Modeling Error for ONS, TMI-1 and ANO-1).
1.14 AREVA Document T5.16-6027344-00, (CONTEMPT LOCA Modeling Error for CR-3).
1.15 AREVA Topical Report BAW-1 0241 P, "BHTP DNB Correlation Applied with LYNXT," December 2002.
1.16 AREVA Proprietary Document 2A4-RELAP5/MOD2-26.OHP, "RELAP5/MOD2 Version 26.OHP Certification File," 4/3/03.
1.17 Letter dated April 10, 2003 from H. N. Berkow USNRC to J. Mallay (Areva),
Subject:
Evaluation of Framatome ANP Preliminary Safety Concern (PSC) 2-00 Relating to Core Flood Line Break and Operator Action Time (TAC No. MA 9973), Project No. 728.
1.18 AREVA Proprietary Document 51-5001731-02, "BWNT LOCA EM Limitations and Restrictions",
6/4/03.
1.19 AREVA Proprietary Document 51-1203953-02, "R5/M2 B&W Plant LOCA Modeling Guidelines",
6/2/03.
5928-04-20128 Page 6 of 7 1.20 AREVA Proprietary Document 32-5025388-00, "BWNT LOCA Containment Pressure Calculation Guidance", 5/30/2003.
1.21 AREVA Proprietary Document 32-5023856-00, "T3XN Script Development", 5/30/03.
1.22 AREVA Proprietary Document 32-5023856-01, 'T3XN Script Development", 7/2/03.
1.23 AREVA Proprietary Document 32-5022597-00, "R3DOC Script Development and Usage",
6/4/03.
1.24 AREVA Proprietary Document 32-5022597-01, "R3DOC Script Development and Usage",
7/2/03.
1.25 AREVA Proprietary Document 32-5022597-02, "R3DOC Script Development and Usage",
11/4/03.
1.26 AREVA Proprietary Document 51-5019524-00, "R3 Input Deck History and Model Updates",
6/2/03.
1.27 AREVA Document 51-5009856-00, "Summary of PSC 2-00 Analyses", 4/13/01.
5928-04-20128 Page 7 of 7 Table 1: Evolution of Changes to BAW-10192P-A [1]
First BAW-Description of Change Date rst 10192P-A Method of Change and/or Approval Introduced Revision 0 LBLOCA SBLOCA 1993 RO.0 Original (approved 1997) 1994 RO.1 CFT Inventory (PSC 5-94)
CFT Inventory (PSC 5-94) 50.46 Change 1999 RO.2 m-Modified RCP degradation Not Applicable 50.46 Change multiplier (PSC 1-99)
Extension of BEACH acceptable 50.46 Change 1999 RO.3 range of application for initial Not Applicable Approved BAW-1 01 66P-A Rev. 5 cladding temperature (2003)
Approved Change 1999 RO.4 MS Cladding (if used)
MS Cladding (if used)
Approved (2000)
BAW-10227P-A (2000)
Not Applicable m3-Modified RCP degradation 50.46 Change multiplier (via PSC 2-00)
Approved via Reference 2.6 (2003) 2000 RO.5 50.46 Change N
t A1 blVoid-dependent cross-flow (via PSC Not Applicable 2-00)
Approved via BAW-1 01 64P-A Rev. 4 2-00)
_(2002) 2002 R0.6 Appendix K Power Uprate Appendix K Power Uprate 50.46 Change
_________(if applicable)
(if applicable) 2002 RO.7 Hot pin modeling for LBLOCA Not Applicable Approved Change BAW-10164P-A Rev. 4 (2002) 2003 RO.8 BHTP CHF correlation for analysis BHTP CHF correlation for analysis 50.46 Change (2003) of Mark-B-HTP fuel (if used) of Mark-B-HTP fuel (if used)
[1] Higher revision levels implicitly include the changes contained in the previous revisions. Some changes are specific to a fuel assembly design or plant change, and are not applicable to all analyses (marked as 'if used" or "if applicable").
ENCLOSURE 2
SUMMARY
OF EM CHANGES AND SIGNIFICANT ERRORS APPLICABLE TO TMI UNIT 1 Each of the 2003 licensing analyses or evaluations applicable to TMI Unit 1 is described below, with the inclusion of the AREVA recommended reporting category and applicable PCT change.
Each activity and the effect on the limiting ECCS analysis are summarized in Enclosure 2,. Limiting ECCS analyses are tracked for the Mark-B9 and the Mark-B1i2 fuel rod designs. The modified Mark-B9 fuel rod design and Mark-B9 gadolinia fuel rods are considered with the limiting Mark-B9 ECCS analysis. The Mark-B12 gadolinia fuel rods are considered with the limiting Mark-B12 ECCS analysis.
2.1 Error Correction for Containment Pressure Input for 177-FA Lowered-Loop LBLOCA Analyses The error in the containment pressure input to LBLOCA, discussed in Generic Issue 1.3 in Enclosure 1, affected the TMI-1 Mark-B9 and Mark-B12 LBLOCA analyses for U02 and gadolinia fuel rods. The most recent applicable LBLOCA analyses were performed with EM RO.3 for zircaloy cladding and with RO.4 for M5 cladding. (The limiting SBLOCA analysis is based on the Mark-B9 assembly with zircaloy cladding, which was analyzed based on EM R0.1. The PSC 2-00 SBLOCA cases were evaluated with EM RO.5, however those cases remain non-limiting with a one minute RCP trip.)
Analyses were specifically performed for CR-3 to determine the magnitude of the PCT change for correction of this error. As summarized in Reference 2.5, the PCT change determined for CR-3 is also applicable to the TMI-1 LBLOCA analyses. Therefore, new PCTs were estimated for application to the Mark-B9 (Reference 2.1 and Reference 2.2) and the Mark-B12 (Reference 2.3) fuel designs. The limiting PCT and PCT changes were reported to Exelon via Reference 2.4.
This issue is considered an Application Error Correction. The LBLOCA PCT change for Mark-B9 fuel is estimated to be (-25) F. The LBLOCA PCT change for Mark-B12 fuel is estimated to be (-35) F.
5928-04-20128 Page 2 of 2 References 2.1 AREVA Proprietary Document 32-1266332-04, "BWOG 20% TP LBLOCA", 12/16/03.
2.2 AREVA Proprietary Document 32-5003746-03, "TMI-1 20% SGTP Mod Mk-B9 and 2 wt% Gadolinia", 12/16/03.
2.3 AREVA Proprietary Document 32-5009152-01, "TMI-1 Mk-B12 LBLOCA Analyses",
12/16/03.
2.4 AREVA Letter FANP-04-245, dated 1/30/04 from J. A. Klingenfus (AREVA) to R. P.
Jaffa (Exelon), "10 CFR 50.46 LBLOCA PCT Reporting Change".
2.5 AREVA Proprietary Document 51-5031991-00, "Resolution of NCR 6027345, CONTEMPT M&E Input", 10/7/03.
2.6 Letter dated April 10, 2003 from H. N. Berkow USNRC to J. Mallay (Areva),
Subject:
Evaluation of Framatome ANP Preliminary Safety Concern (PSC) 2-00 Relating to Core Flood Line Break and Operator Action Time (TAC No. MA 9973), Project No. 728.
ENCLOSURE 2 10 CFR 50.46 "Acceptance Criteria for Emergency Core Cooling Systems for Light-Water Nuclear Power Reactors" Report of the Emergency Core Cooling System Evaluation Model Changes and Errors Assessments as of December 31, 2003 Peak Cladding Temperature Rack-Up Sheets PLANT NAME:
ECCS EVALUATION MODEL:
REPORT REVISION DUE DATE:
CURRENT OPERATING CYCLE:
Three Mile Island Unit 1 Small Break Loss of Coolant Accident (SBLOCA)
June 19, 2004 15 ANALYSIS OF RECORD (AOR)
Evaluation Model: BWNT '
Calculation: Framatome ANP 86-5011294-00, March 2001 Fuel: Mark-B9, Mark-B12 Limiting Fuel Type: Mark-B12 Limiting Single Failure: Loss of Offsite Power Steam Generator Tube Plugging (SGTP) = 20%
Limiting Break Size and Location: 0.05 ft2 Break in Cold Leg Pump Discharge Piping Reference Peak Cladding Temperature (PCT)
PCT=
14540F 2 MARGIN ALLOCATION A. PRIOR LOCA MODEL ASSESSMENTS 10 CFR 50.46 Report dated June 6, 2002 10 CFR 50.46 Report dated June 19, 2003 NET PCT A PCT =
A PCT =
0F 0F PCT=
14540F B. CURRENT LOCA MODEL ASSESSMENTS Change of RELAP5/MOD2-B&W for Mark-B-HTP Fuel CHF Correlation (see Enclosure 1)
A PCT =
0F 14540 F NET PCT PCT=
' The BWNT EM is based on RELAP5/MOD2-B&W.
2This represents a 420F increase over the reference PCT from the earlier Mk-B9 SBLOCA analysis.
Page 2 of 3 (continued)
PLANT NAME:
ECCS EVALUATION MODEL:
REPORT REVISION DUE DATE:
CURRENT OPERATING CYCLE:
Three Mile Island Unit 1 Large Break Loss of Coolant Accident (LBLOCA)
June 19, 2004 15 ANALYSIS OF RECORD (AOR)
Evaluation Model: BWNT3 Calculations: Framatome ANP 86-5002073-02, July 1999 (Mark-B9)
Framatome ANP 86-5011294-00, March 2001 (Mark-B12)
Limiting Single Failure: Loss of Offsite Power Steam Generator Tube Plugging (SGTP) = 20%
Limiting Break Size and Location: Guillotine Break in Cold Leg Pump Discharge Piping Fuel Type:
Limiting Fuel Type:
Reference Peak Cladding Temperature (PCT)
Mark-B9 Mark-B9 20830 F Mark-B312 Mark-B112 19890 F PCT=
MARGIN ALLOCATION A. PRIOR LOCA MODEL ASSESSMENTS 10 CFR 50.46 Report dated June 5, 2000 10 CFR 50.46 Report dated June 11, 2001 10 CFR 50.46 Report dated June 6, 2002 10 CFR 50.46 Report dated June 19, 2003 A PCT =
A PCT =
A PCT =
A PCT=
0F 00F 0F 0F N/A N/A 0F 0F NET PCT PCT =
20830F 19890F 4 B. CURRENT LOCA MODEL ASSESSMENTS Change of RELAP5/MOD2-B&W for Mark-B-HTP Fuel CHF Correlation (see Enclosure 1)
A PCT =
0F 0F Error Correction for Containment Pressure Input for 177-FA Lowered-Loop LBLOCA Analyses (see Enclosure 1)
-250F
-35°F PCT =
2058°F 1953.8°F 3 The BWNT EM is based on RELAP5/MOD2-B&W.
4 The actual analysis result from RELAP5 was 1988.8 F.
Page 3 of 3