Question Number:
1 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only B
K/A 003000K501 QUESTION The plant was restarted following a forced outage.
Loop flow measurement has determined the C RCP impeller has degraded such that its RCS loop flow has DECREASED by 5% from its original value.
The other three RCS loop flows remain UNCHANGED.
Which one of the following would be a result of the decreased flow rate in the C loop?
a.
Demand on the Pressurizer variable heaters at 2235 psig will be lower.
b.
The reactor core will operate closer to DNB when at full power.
c.
Delta-T in the C RCS loop at full power will be lower.
d.
Steam pressure in the C S/G at full power will be higher.
ANSWER B
REFERENCE ILT Fundamentals Lesson Plan Power Distribution Chapter 3, Thermal Limits; page 15-16. I1-PD-XL-03 Modified High
Question Number:
2 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only B
K/A 004000K201 QUESTION The following plant conditions exist:
Core alterations are in progress on Unit 1.
Conditions are such that Emergency Boration is required.
All offsite power has been lost.
Both ESF Buses are energized.
Which one of the following Emergency Boration methods should be used?
a.
Emergency Boration valve 1CV8104 b.
Normal Boration path through the blender c.
Refueling Water Storage Tank (RWST) d.
Manual Emergency Boration valve 1CV8439 ANSWER C
REFERENCE BOP AB-E1 page 3 Cog Level - High Source - bank
Question Number:
3 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only B
K/A 005000K603 QUESTION Given the following conditions:
The RCS is water solid in MODE 5 The A RH pump is operating in shutdown cooling and RCS temperature is being maintained at 180 deg F via throttling of the A train RH Hx valves.
Instrument Air is lost to the A RH Hx room resulting in RH606 (RH Hx Outlet Valve) and RH618 (RH Hx Bypass Valve) repositioning to their failure positions.
Assuming NO operator action, which of the following describes the plant response over the next ten minutes?
'A' RHR suction pressure will ?
a.
INCREASE because RH606 fails CLOSED and RH618 fails OPEN.
b.
DECREASE because RH606 fails OPEN and RH618 fails CLOSED.
c.
DECREASE because RH606 fails CLOSED and RH618 fails OPEN d.
INCREASE because RH606 fails OPEN and RH618 fails CLOSED ANSWER B
REFERENCE ILT Systems LP Ch 18 page 12; ILT Systems Ch 53, page 52 Cog Level High Bank
Question Number:
4 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only B
K/A 006000A201 QUESTION Given the following plant conditions:
Unit 2 has experienced a large break LOCA During the ECCS injection phase the 2B RH pump tripped due to a overheated bearing that seized The crew has now transitioned to 2BEP ES-1.3, TRANSFER TO COLD LEG RECIRCULATION In this situation the concern is _____(1)_____, therefore 2BEP ES-1.3 will direct valve alignments such that the 2A RH pump will be injecting into ____(2)_____.
a.
(1) inadequate core flow (2) all 4 cold legs, and supplying suction for only the 2 SI pumps.
b.
(1) inadequate core flow (2) all 4 cold legs, and supplying suction for only the 2 CV pumps.
c.
(1) 2A RH pump runout (2) only 2 cold legs, and supplying suction for both CV and both SI pumps.
d.
(1) 2A RH pump runout (2) only 2 cold legs, and supplying suction for only the 2 CV pumps.
ANSWER C
REFERENCE 2BEP ES-1.3 steps 5 and 8; Horsenote ECCS-2 WOG ERG background for ES-1.3, page 4 Cog Level High New
Question Number:
5 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only B
K/A 007000A102 QUESTION The plant is operating at 40% power with all systems in a normal lineup. Annunciator 1-12-B7, "PRT PRESS HIGH" alarms. PRT pressure is currently 6 psig.
In order to clear this high pressure alarm, which of the following would be the appropriate action?
a.
Align and verify the start of a RCDT pump.
b.
Align the PRT to drain to the RCDT.
c.
Vent the PRT to the Waste Gas header.
d.
ANSWER A
REFERENCE P & ID M-60, sheet 6 & M-70 sheet 1 BOP RY-3, page 3 note: BOP RY-4 page 2 Cog Level High Bank
Question Number:
6 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only B
K/A 008000K303 QUESTION The unit has just experienced a spurious Containment Phase B actuation.
In regard to RCP components ?
a.
seal cooling is still being provided; motor bearing cooling is NOT.
b.
BOTH motor bearing cooling and seal cooling are still being provided.
c.
NEITHER motor bearing cooling NOR seal cooling is being provided.
d.
motor bearing cooling is still being provided; seal cooling is NOT.
ANSWER A
REFERENCE ILT Systems LP Ch 19, page 32 ILT Systems LP Ch 13, page 20 & 21 Cog Level High New
Question Number:
7 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only B
K/A 010000A401 QUESTION The following conditions exist on Unit 1:
A load rejection has occurred from 100% power Reactor power is now 80%
Pressurizer level is 56%
Pressurizer pressure is 2275 psig RCS Tave is 582 deg F What Pressurizer Pressure Control System indications are expected on the Main Control Board?
a, Backup and proportional heaters are fully on.
b.
Porportional heaters have modulated on.
c.
Pressurizer spray valves AND pressurizer PORVs are open.
d.
Pressurizer spray valves have modulated open.
ANSWER D
REFERENCE ILT Systems LP Ch 14, pages 8 - 10 Cog Level High Bank
Question Number:
8 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only B
K/A 012000K406 QUESTION Given:
Unit 1 P-7 Bypass Permissive light is LIT Which of the following conditions will cause a Unit 1 reactor trip?
a.
PZR Level of 94%
b.
PZR Pressure of 2390 psig c.
All 4 RCP breakers open d.
PZR Pressure of 1880 psig ANSWER B
REFERENCE ILT Systems LP Ch 60b, pages 13 thru 16 Cog Level High Bank
Question Number:
9 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only B
K/A 013000A302 QUESTION Given the following plant status:
Unit 1 is at full power Last shift Containment Pressure Channel II failed and the Tech Spec required actions were performed A few seconds ago Containment Pressure Channel III failed high Which of the following automatic actions would be expected to be observed on 1PM06J?
a.
Closure of all MSIVs only.
b.
Closure of all MSIVs and start of ECCS pumps.
c.
Start of ECCS pumps only.
d.
Closure of all MSIVs, start of CS pumps, and start of ECCS pumps.
ANSWER B
REFERENCE ILT Systems LP Ch 61, pages 15-16, 21 ILT Systems Ch 40, pages 31-32 Cog Level High New
Question Number:
10 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only B
K/A 0130002449 QUESTION Assume the following conditions exist on Unit 2:
A reactor trip has occurred from full power PZR pressure is 1820 psig and steadily decreasing Steps 1 through 3 of 2BEP-0, Reactor Trip or Safety Injection, have been properly verified Per step 4 of 2BEP-0, an operator checks the Safety Injection annunciators and the Safety Injection Bypass Permissive annunciator, NONE OF WHICH ARE ILLUMINATED, and NO SI equipment has automatically actuated. For this reactor trip event, SI has?
a.
NOT occurred and is NOT required. The operator should transfer to 2 BEP ES-0.1, 'Reactor Trip Response'.
b.
occurred and is required.
c.
occurred but is NOT required. The operator should immediately terminate SI.
d.
NOT occurred but is required. The operator should manually initiate SI.
ANSWER D
REFERENCE 2BEP-0, page 5 Cog Level High Bank
Question Number:
11 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only B
K/A 022000K201 QUESTION Which of the following statements is correct concerning the power supplies to the RCFCs on Unit 1?
a.
All RCFC high speed windings are powered from 131X and all low speed windings are powered from 132X.
b.
RCFC 1A & 1C are powered from 133X and RCFC 1B & 1D are powered from 134X.
c.
RCFC 1A & 1C are powered from 131X and RCFC 1B & 1D are powered from 132X.
d.
RCFC 1A & 1B are powered from 131X and RCFC 1C & 1D are powered from 132X.
ANSWER C
REFERENCE BOP VP-E1A page 3, BOP VP-E1B page 3 Cog Level Low modified
Question Number:
12 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only B
K/A 0220002133 QUESTION The 2A, 2B, and 2D RCFCs are operating in high speed.
The 2C RCFC is in standby. The following indications are observed on the Unit 2 RCFC Dry Bulb temperatures:
2A RCFC Inlet Temperature - 119 deg F 2B RCFC Inlet Temperature - 118 deg F 2C RCFC Inlet Temperature - 127 deg F 2D RCFC Inlet Temperature - 121 deg F Per the Containment Air Temperature Technical Specification:
a.
The action requirement must be applied because the average of ALL the RCFC temperatures exceeds the LCO b.
NO action is necessary because ALL the RCFC temperatures are within their appropriate LCO limit(s).
c.
The action requirement must be applied because ONE of the OPERATING RCFCs temperatures is above the LCO upper limit.
d.
NO action is necessary because the average temperature of ALL OPERATING RCFCs is below the LCO upper limit.
ANSWER D
REFERENCE LCO 3.6.5, SR 3.6.5.1 2BOSR 0.1-1,2,3 page D12 Cog Level High Bank
Question Number:
13 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only B
K/A 026000A104 QUESTION Consider each of the following situations separately; assume Mode 1 operations.
Over the next 20 minutes, which of the following situations would be expected to raise the humidity level in a.
A RCFC is swapped from low to high speed operation on PM06J.
b.
Containment Phase B Isolation is manually actuated via 2/2 switches on PM06J.
c.
CV8160, Letdown Orifices Outlet Header Isolation valve, inadvertently closes.
d.
A #1 seal failure is experienced on a RCP.
ANSWER B
REFERENCE ILT Systems Ch 59 page 11 Cog Level High New
Question Number:
14 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only B
K/A 039000A105 QUESTION The time is 0300 The plant is in MODE 3 at 555 deg F, EOL, following a trip from 100% power moments ago.
The following events occur:
The Unit NSO reports that Tave has begun decreasing at a rate of approximately 1 deg F/min.
The crew receives a report that one of the SG Safety Valves on the "C" SG is passing steam to the atmosphere.
The Unit Supervisor confirms an RCS cooldown rate of 5 deg F in the last 5 minutes.
Assuming the RCS cooldown rate is constant, and NO actions are taken in response to the stuck open safety valve, which of the following conditions will exist by time 0400?
- 1. Main Steamline Isolation.
- 2. Tech Spec limit for RCS Cooldown Rate will be exceeded.
- 3. The actual amount by which the reactor is shutdown will decrease.
- 4. A Pressurized Thermal Shock (PTS) challenge to reactor vessel integrity will occur.
a.
1 and 3 b.
2 Only c.
3 Only d.
2 and 4 ANSWER A
REFERENCE steam tables ILT Systems LP Ch 23 page 9-10 Cog Level High bank
Question Number:
15 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only B
K/A 039000A205 QUESTION Given the following plant conditions:
Unit 2 is performing a reactor startup at End of Core Life (EOL)
Reactor power is stable at 1E-3% while taking critical data Steam Header pressure transmitter 2PT-507 fails HIGH Reactor power will _________ ; and the transient can be mitigated if the board operator places a.
increase; one or more S/G PORV contollers in manual and increases demand b.
decrease; a Steam Dump Bypass Interlock switch to OFF/RESET.
c.
decrease; the Steam Dump Mode Selector switch to Tave position.
d.
increase; the Steam Dump Main Steam Header Pressure Controller in manual and reduces demand.
ANSWER D
REFERENCE ILT Systems Ch 24, page 18-19 ILT Fundamentals Ch RT3 BAP 300-1, OP-AA-100, Conduct of Operations Manual, Byron Addendum C.1.h on page 4.
Cog Level High New
Question Number:
16 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only B
K/A 056000K103 QUESTION Which of the following describes component response to a Main Feed pump LOW NPSH signal:
a.
The CD152 valve (CD pump recirc) OPENS and the standby CD/CB aux oil pumps start, then the standby CD/CB pump starts.
b.
The standby CD/CB pump starts, then the standby CD/CB aux oil pumps start and the CD152 valve (CD pump recirc) OPENS.
c.
The CD152 valve (CD pump recirc) CLOSES and the standby CD/CB aux oil pump starts, then the standby CD/CB pump starts.
d.
The standby CD/CB pump starts, then the standby CD/CB aux oil pumps start and the CD152 valve (CD pump recirc) CLOSES.
ANSWER C
REFERENCE ILT Systems LP Ch 25, page 48-49, 55 Cog Level Low bank
Question Number:
17 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only B
K/A 059000A401 QUESTION Given the following:
Unit 1 experienced a reactor trip and Safety Injection from full power when DC Bus 112 deenergized.
While performing step 5 to Verify FW Isolation of 1BEP-0, Reactor Trip Or Safety Injection the NSO noted the 1B FW Pump did NOT automatically trip, and its TURB LOSS OF DC TO TRIP lite is illuminated.
Under these circumstances, what action must be performed to trip the 1B FW Pump?
a.
Manually trip 1B FW Pump via the MCB pushbutton.
b.
Manually initiate FW isolation via the MCB pushbutton.
c.
Select Speed Setter Control Mode then depress the DECREASE SPEED pushbutton for 1B FW Pump.
d.
Dispatch a NLO to locally trip 1B FW Pump via its overspeed trip plunger.
ANSWER D
REFERENCE ILT Systems LP Ch 37b, page 34 Cog Level High New
Question Number:
18 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only B
K/A 061000K412 QUESTION Given the following plant conditions:
Unit 2 just entered Mode 1 during plant startup.
The Start Up FW Pump is maintaining S/G levels via the Feed Reg Bypass Valves in automatic.
A grid disturbance has resulted in a Loss of Offsite Power (LOOP) for Unit 2.
One minute later, by what method is RCS heat being removed, and what is maintaining the heat sink?
a.
Natural Circulation; Aux Feedwater System b.
Forced Circulation; Main Feedwater System c.
Forced Circulation; Aux Feedwater System d.
Natural Circulation; Main Feedwater System ANSWER A
REFERENCE ILT Systems LP Ch 13, page 18-19 ILT Systems LP Ch 4, pages 34-37 Cog Level High New
Question Number:
19 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only B
K/A 061000A302 QUESTION Following a reactor trip with NO SI, a transition is made to BEP ES-0.1, Reactor Trip Response.
Which of the following describes the basis for the RNO actions of step 2, MAINTAIN RCS TEMPERATURE that directs:
(1) Verifying total feed flow is greater than 500 GPM; (2) then throttling it once a minimum S/G water level is obtained?
a.
(1) Ensure enough feedwater flow for decay heat removal; (2) then limit overcooling of the RCS.
b.
(1) Allow enough Aux Feed flow in case of a Main Feed Line break; (2) then limit runout of the Aux Feed pumps.
c.
(1) Ensure enough feedwater flow for decay heat removal; (2) then limit runout of the Aux Feed pumps.
d.
(1) Allow enough Aux Feed flow in case of a Main Feed Line break; (2) then limit overcooling of the RCS.
ANSWER A
REFERENCE ILT Procedure LP page 57 for BEP ES-0.1 step 2 WOG Background Document for ES-0.1 step 1 Cog Level Low Modified
Question Number:
20 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only B
K/A 062000K102 QUESTION The following conditions exist on Unit 1:
Bus 141 is powered from its normal source D/G 1A surveillance is being performed with the D/G paralleled to the bus What would occur if a failure of the undervoltage relay results in a sensed undervoltage condition on Bus 141?
SAT feeder breaker ACB 1412 ?
a.
will open but D/G feeder breaker ACB 1413 will remain closed. The Safe Shutdown loads will NOT sequence and CANNOT be manually started from the control room.
b.
and D/G feeder breaker ACB 1413 remain closed. The Safe Shutdown loads will NOT sequence and CANNOT be manually started from the control room.
c.
and D/G feeder breaker ACB 1413 will open. After a short delay, ACB 1413 will close and the Safe Shutdown loads will sequence.
d.
will open but D/G feeder breaker ACB 1413 will remain closed. The Safe Shutdown loads will sequence normally.
ANSWER A
REFERENCE ILT Systems LP Ch 9, page 45 Horse Note DG-2 Cog Level High bank
Question Number:
21 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only B
K/A 063000K103 QUESTION The purpose of the 125 VDC battery is to supply 125 VDC to:
a.
ESF and non-ESF DC buses during loss of all AC power.
b.
ESF and non-ESF DC buses during normal operation.
c.
Only ESF DC buses during normal operation.
d.
Only ESF DC buses during loss of off-site power.
ANSWER A
REFERENCE ILT Systems Ch 8a, pages 5-6, 13 Cog Level Low Bank
Question Number:
22 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only B
K/A 0630002431 QUESTION Given the following sequence of events:
Following a reactor trip, Unit 1 in MODE 3 at 557 deg F, with the crew performing steps of 1BEP ES-0.1, REACTOR TRIP RESPONSE.
Annunciator 1-21-E10, 125V DC PNL 111/113 VOLT LOW alarms.
The MCB indication for DC Bus 111 indicates 0 volts Pressurizer Spray Valve 1RY455B is stuck open and RCS pressure is LOWERING.
To stop the RCS depressurization, the 1____ RCP must be shutdown. This can be done locally at the breaker _________________.
a.
C; only b.
C; or remotely c.
D; only d.
D; or remotely ANSWER C
REFERENCE BEP ES-0.1 step 6b RNO (page 8) for direction to trip 1D RCP for this situation.
ILT Systems LP Ch 13, page 18 for RCP control power BOA ELEC-5, Symptoms or Entry Conditions (page 1), and Attachment A (page 6).
Cog Level High Bank
Question Number:
23 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only B
K/A 064000A202 QUESTION Given the following:
A Unit 2 Loss of Offsite Power event (LOOP) was caused by a fault on SAT 242-2.
Both 2A and 2B Diesel Generators (D/Gs) started on their respective bus undervoltage condition.
2A D/G output breaker ACB 2413 closed in to energize bus 241.
2B D/G output breaker ACB 2423 did NOT close and bus 242 is still de-energized The MCB BUS ALIVE indicator lite for the 2A D/G is lit.
The MCB BUS ALIVE indicator lite for the 2B D/G is NOT lit.
Which of the following is the reason the 2B D/G did NOT automatically energize bus 242; and what can be done to reenergize bus 242?
The status of the 2B BUS ALIVE lite indicates the D/G did not achieve proper ________ to auto close ACB 2423; and in order to reenergize bus 242 it will be necessary to ______________.
a.
VOLTAGE; go to RAISE on the Voltage Regulator control switch until proper VOLTAGE is obtained b.
FREQUENCY; go to RAISE on the Governor Adjust switch until proper FREQUENCY is obtained c.
VOLTAGE; use the unit crosstie breaker ACB 2424 d.
FREQUENCY; restore offsite power ANSWER C
REFERENCE ILT Systems LP Ch 9, pages 28-29, 33-34 BOA ELEC-3, pages 2, 27-28 6E-2-4004B, 6E-2-4021A Cog Level High New
Question Number:
24 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only B
K/A 073000K301 QUESTION Given the following conditions:
Containment Mini-Purge Supply and Exhaust Systems are in operation.
Containment Fuel Handling Incident Rad Monitor, RE-AR012J spikes high.
In response to this Radiation Monitor spike ?
a.
ALL Containment Mini-Purge Supply and Exhaust valves close and the running fans remain running.
b.
ONE train of Containment Mini-Purge Supply and Exhaust valves close and the running fans remain running.
c.
ALL Containment Mini-Purge Supply and Exhaust valves close and the running fans trip.
d.
ONE train of Containment Mini-Purge Supply and Exhaust valves close and the running fans trip.
ANSWER D
REFERENCE ILT Systems LP Ch 42, page 52-53 ILT Systems LP Ch 49, page 30 Cog Level Low Bank
Question Number:
25 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only B
K/A 076000A401 QUESTION Both Units are at 100% power, with the 1A and 2B SX pumps running. The 1A SX pump trips on over current.
In accordance with 1BOA Pri-7, SX Malfunction, the initial action by the Unit 1 NSO should be to?
a.
verify the 1B SX pump automatically starts.
b.
coordinate with Unit 2 NSO to start the 2A SX pump and open 1SX005 and 2SX005, the Unit 0 CC HX Inlet valves.
c.
verify open 1SX033 and 1SX034, the SX Pump Crosstie valves.
d.
manually start the 1B SX pump.
ANSWER D
REFERENCE 1BOA Pri-7, page 2, step 1 RNO Cog Level Low Bank
Question Number:
26 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only B
K/A 078000K102 QUESTION Given:
Both units are operating normally at 100% power Unit 2 station air compressor (SAC) is supplying all instrument and service air needs The remaining two SACs are in standby Maintenance is being performed in the Unit 2 turbine building A workman drops a toolbox from a raised platform The dropped toolbox severs the 4-inch turbine building Service Air header Which of the following describes the plant response?
a.
Only unit 2 will trip due to an immediate loss of instrument air header pressure.
b.
Both units will trip due to an immediate loss of instrument air header pressure.
c.
Both units will trip, but only after instrument air header pressure bleeds down due to instrument air loads.
d.
Only unit 2 will trip, but only after instrument air header pressure bleeds down due to instrument air loads.
ANSWER C
REFERENCE ILT Systems LP Ch 53, pages 55, 57, TPs 4 & 5 Cog Level High Bank
Question Number:
27 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only B
K/A 078000K403 QUESTION On 5/23/1996, Byron Station Unit 1 experienced a Loss of Offsite Power (LOOP) when a fault occurred in a Bus Duct.
Prior to the event:
Unit 1 was in Mode 5 Unit 2 was at 100% power The Unit 2 Station Air Compressor (SAC) was Out of Service The 0C Non-Essential Service Water Pump (WS pp) was Out of Service Two minutes after the LOOP occurred, operators manually tripped Unit 2 on decreasing steam generator levels as secondary system air operated valves began moving to their failure positions.
Prior to the Unit-2 manual trip, had the Unit-2 SAC been in standby instead of Out of Service, it would ?
a.
need to be manually started by placing the local control switch in COMP RUN.
b.
need to be shutdown until backup cooling water from FP was manually aligned.
c.
automatically start on low Instrument Air Receiver pressure, but soon trip on HIGH OIL or AIR TEMPERATURE.
d.
automatically start on low Service Air Receiver pressure, but trip immediately on SURGE.
ANSWER B
REFERENCE 0BOA SEC-5, step 3 RNO (page 3 of 13)
ILT Systems LP Ch 53, pages 67, 69 Cog Level High New
Question Number:
28 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only B
K/A 103000K105 QUESTION The BAR for Annunciator 2-1-B2, CNMT HATCH DOOR SEAL TROUBLE lists the 3 alarm inputs as coming from:
SUPPLY AIR PRESSURE HIGH SUPPLY AIR PRESSURE LOW SUPPLY AIR FLOW HIGH.
If the CNMT HATCH DOOR SEAL TROUBLE annunciator came in due to high air FLOW and low air PRESSURE, then cleared 8 minutes later, which of the following should be considered valid?
a.
A Containment Hatch Air Lock is INOPERABLE.
b.
A Containment Hatch Air Lock Door interlock has failed.
c.
The Containment Overall Leakage Rate has increased.
d.
Personnel have just passed through the Air Lock Doors.
ANSWER D
REFERENCE BAR 2-1-B2 SR 3.6.2.1 Note 1 Cog Level High New
Question Number:
29 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only B
K/A 0020002406 QUESTION Step 9 of BEP-1, LOSS OF REACTOR OR SECONDARY COOLANT, directs the operator to check all steam generator pressures STABLE OR INCREASING.
If any steam generator pressure is DECREASING, the operator is directed to return to step 1 of BEP-1.
Which of the following describes why the operator should NOT proceed past step 9 while a steam generator is still depressurizing?
a.
BEP-1 provides NO guidance for faulted steam generator isolation past step 9.
b.
The RCS cooldown rate must be under control in order for subsequent BEP-1 steps to be effectively implemented.
c.
SI Termination criteria could NOT initially be met, and more restrictive termination criteria would be encountered in BEP ES-1.2, POST LOCA COOLDOWN AND DEPRESSURIZATION.
d.
SI Termination criteria does NOT exist in BEP ES-1.2, POST LOCA COOLDOWN AND DEPRESSURIZATION. A loop back to step 1 ensures that SI Termination criteria is met in BEP-1.
ANSWER C
REFERENCE Westinghouse Background Document for EP-1, step 9 (page 86)
Cog Level High Bank
Question Number:
30 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only B
K/A 011000K302 QUESTION Charging, letdown, and PZR level control system are in automatic. A&C letdown orifices are in service. The following conditions exist:
Letdown Hx Outlet Flow FI-132 118 gpm Charging Header Flow FI-121 127 gpm Total seal flow to RCPs FI-142-145 30 gpm The controlling PZR level channel fails high to an indicated 100% level. Which of the following describes the short term effect on total RCP seal injection flow, assuming NO operator action?
Total seal injection flow ?
a.
decreases to 0 gpm.
b.
decreases to about 12 gpm.
c.
remains about 30 gpm.
d.
increases to about 50 gpm.
ANSWER B
REFERENCE
-ILT Systems Ch 14 pages 50-51, Ch 15a pages 29-30 Cog Level High Bank
Question Number:
31 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only B
K/A 016000K107 QUESTION The emergency procedures require RCPs to be tripped during certain primary loss of coolant conditions. Prior to tripping RCPs, it must be verified that ECCS flow is occurring to the core.
As long as a controlled cooldown is NOT in progress, low ____(1)____ is used to indicate the LOCA conditions and _____(2)_____ flow indication can be used to indicate adequate ECCS flow to the core.
a.
(1) PZR pressure (2) High Head SI b.
(1) RCS pressure (2) Charging header c.
(1) PZR pressure (2) Charging header d.
(1) RCS pressure (2) SI pump discharge ANSWER D
REFERENCE BEP-0 step 26/page 23 or OAS Cog Level Low New
Question Number:
32 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only B
K/A 028000A403 QUESTION A step in BEP-1, LOSS OF REACTOR OR SECONDARY COOLANT has the crew place the Hydrogen Monitors in service per BOP PS-9, POST LOCA CONTAINMENT HYDROGEN MONITORING SYSTEM OPERATION.
Which of the following actions will be necessary to obtain valid indication of the containment hydrogen concentration:
- 1. Verify/Reset SI
- 2. Verify/Reset Containment Phase A Isolation and open isolation valves
- 3. Verify/Reset Containment Phase B Isolation and open isolation valves
- 4. Switch the Hydrogen Monitors from OFF to ON on panel 1PM12J
- 5. Place the HI/LO Range Switch to HI
- 6. Wait several minutes before taking readings a.
1, 2, 4 b.
2, 5, 6 c.
2, 4, 6 d.
3, 4, 5 ANSWER C
REFERENCE BEP-1 steps 11c/d on page 17 BOP PS-9 pages 2-3 Cog Level Low New
Question Number:
33 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only B
K/A 034000K602 QUESTION Actuation of the interlock function of 0RT-AR039J, the Fuel Handling Building Crane Radiation Monitor, will inhibit movement of the Fuel Handling Building Crane's ?
a.
upward motion only.
b.
downward and lateral motion.
c.
upward and lateral motion.
d.
downward motion only.
ANSWER A
REFERENCE ILT Systems LP Ch 49, page 27 Cog Level Low Bank
Question Number:
34 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only B
K/A 041000A305 QUESTION
- The crew is preparing for a Reactor Startup.
Assuming PT-507, the Main Steam Header Pressure Channel, has a range of 0 to 1500 psig:
At what potentiometer value should PK-507, the Steam Dump Main Steam Header Pressure Controller be set in order to automatically maintain NO-LOAD Tave?
a.
6.66 turns b.
7.28 turns c.
7.38 turns d.
7.43 turns ANSWER B
REFERENCE ILT Systems Ch 24, pages 6-7 Cog Level High New
Question Number:
35 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only B
K/A 045000K518 QUESTION Per 2BOA TG-8, TURBINE TRIP BELOW P8, following a Unit 2 Turbine Trip below 30%
power ?
a.
both Aux Feedwater pumps are started/verified running to ensure adequate SG levels are maintained.
b.
the control rods are required to be maintained in automatic to control primary system temperature.
c.
a manual reactor trip is required if the condenser is NOT available to maintain the heat sink.
d.
the reactor is stabilized at 25-30% power to minimize xenon transients.
ANSWER C
REFERENCE 2BOA TG-8 LP for steps 2, 3, 4 Cog Level High Bank
Question Number:
36 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only B
K/A 068000A204 QUESTION An Assist NSO initiated a liquid release in accordance with BCP 400-TWX01, LIQUID RADWASTE RELEASE FORM FOR RELEASE TANK 0WX01T.
A few minutes later the same NSO noted CW Blowdown flowrate is indicating 8000 gpm.
The NSO contacted the Radwaste Panel to check the release status and was informed the liquid release from 0WX01T was still in progress.
NO alarms are currently lit on the Center Desk annunciator panels.
Under these circumstances ?
a.
the release failed to automatically isolate; the NSO should initiate the manual interlock function for 0PR001J, the Liquid Radwaste Effluent Radiation Monitor.
b.
a low flow alarm failed to come in on the MCB; the NSO should open 0CW018A/B, the CW Blowdown Spray valves to increase blowdown flow.
c.
the release failed to automatically isolate; the NSO should direct the Radwaste Operator to close 0WX353, the Liquid Release Isolation valve.
d.
a low flow alarm failed to come in on the MCB; the NSO should direct the Radwaste Operator to reduce release tank flow rate to 80% of the original value.
ANSWER C
REFERENCE BAR 0PL01J-7-B6 (Radwaste Panel)
BCP 400-TWX01, page 23 Cog Level High Modified
Question Number:
37 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only B
K/A 079000K401 QUESTION The following plant conditions exist:
Instrument Air Header pressure is at 50 psig and decreasing.
0BOA SEC-4, Loss of Instrument Air, Attachment A, SAC Startup During Abnormal Conditions, directs connecting a nitrogen bottle for backup control air to the Station Air Compressor to be started.
This is done because on a loss of Instrument Air, the Station Air Compressor's ?
a.
Unloader Valve fails open and the Compressor Discharge Valve fails open.
b.
Unloader Valve fails closed and the Compressor Discharge Valve fails closed.
c.
Unloader Valve fails closed and the Compressor Discharge Valve fails open.
d.
Unloader Valve fails open and the Compressor Discharge Valve fails closed.
ANSWER D
REFERENCE ILT Systems LP Ch 53, page 48 Cog Level Low Bank
Question Number:
38 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only B
K/A 086000A103 QUESTION A NLO is performing Outside Rounds and reports to the Control Room that the door hinges for the 0B Fire Pump room are broken.
In this situation, this is an impairment of?
a.
a fire door.
b.
the ventilation when the Fire Pump is running.
c.
a flood seal.
d.
a security barrier.
ANSWER A
REFERENCE BAP 1100-3A3 page 20 Cog Level Low New
Question Number:
39 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only B
K/A 000008K102 QUESTION The crew has diagnosed a Pressurizer (PZR) Vapor Space Accident.
The following is the procedural flowpath followed:
BEP-0, REACTOR TRIP OR SAFETY INJECTION BEP-1, LOSS OF REACTOR OR SECONDARY COOLANT BEP ES-1.2, POST LOCA COOLDOWN AND DEPRESSURIZATION 90 minutes after the reactor trip, performing the COOLDOWN and DEPRESSURIZATION of the plant per BEP ES-1.2 will result in ?
a.
a stable flowrate out the vapor space leak, and decreasing PZR level.
b.
a reduction in flowrate out the vapor space leak, and increasing PZR level.
c.
a reduction in flowrate out the vapor space leak, and PZR level offscale high.
d.
a stable flowrate out the vapor space leak, and stable PZR level.
ANSWER C
REFERENCE WOG ERG ES-1.2, pages 47, 54, 73, 74, 76 Cog Level High New
Question Number:
40 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only B
K/A 000009A210 QUESTION Consider plant parameter response to each of the following accidents separately:
Small Break LOCA Faulted Steam Generator inside Containment Steam Generator Tube Rupture Which of the following plant parameters is used to differentiate the small break LOCA from either the Faulted Steam Generator inside Containment or the Steam Generator Tube Rupture events?
Only the small break LOCA would exhibit a change in:
a.
Containment airborne activity.
b.
Pressurizer pressure.
c.
Containment pressure.
d.
Steam Generator level.
ANSWER A
REFERENCE BEP-0, steps 27, 28, 29 Cog Level High New
Question Number:
41 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only B
K/A 000017K207 QUESTION Given the following:
A loss of RCP seal cooling resulted in hot seal package conditions The reactor was tripped, then all RCPs were tripped The plant has been cooled down to <250 deg F on natural circulation.
Select from the following options to complete the statement describing how the RCP seal packages will be further cooled in accordance with BOA RCP-2, Attachment A, RCP HOT SEAL PACKAGE COOLDOWN.
Establishing ____(1)_____, maintaining <1 deg F/min cooldown rate until ____(2)______
temperature is less than 235 deg F and ____(3)______ temperature is less than 225 deg F.
(1)
(2)
(3) a.
seal injection; lower bearing; seal outlet b.
thermal barrier cooling; lower bearing; seal outlet c.
thermal barrier cooling; seal outlet; lower bearing d.
seal injection; seal outlet; lower bearing ANSWER C
REFERENCE BOA RCP-2, Attachment A, pages 2 thru 5 of 5 Cog Level Low Bank
Question Number:
42 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only B
K/A 000022K303 QUESTION The plant is operating at 100% power. An NLO reports to the control room that the charging line containment isolation valve (CV8105) has a significant bonnet leak, approx. 20 to 30 gpm.
The SM directs the control room operators to isolate letdown, secure normal charging, and then place excess letdown in service. NO changes are to be made in the Seal Return flowpath.
Under these conditions, excess letdown is required to:
a.
Restore VCT hydrogen-control capability.
b.
Permit maintenance of a constant RCS inventory/PZR level.
c.
Provide a means of purifying reactor coolant by aligning flow through the mixed-bed demineralizers.
d.
Ensure an adequate cooling water flow rate through the RCP seals while charging flow is isolated.
ANSWER B
REFERENCE ILT Systems LP Ch 15a, page 34 Cog Level High Bank
Question Number:
43 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only B
K/A 000025K101 QUESTION While performing actions of BOA S/D-2, SHUTDOWN LOCA, the operator is directed to check RCS hot leg temperatures less than 260 deg F prior to aligning any RH pump suction to the RWST.
For example, aligning a RH pump to the RWST with suction piping temperature of 340 deg F
?
a.
exceeds the RH pump's design temperature.
b.
may cause damage to the HUT if the RH suction relief valve were to lift.
c.
may cause steam binding at the RH pump suction when aligned to the RWST.
d.
exceeds the RH heat exchanger's heat removal capacity.
ANSWER C
REFERENCE BOA S/D-2, Attachment D, Note prior to Step 1 Cog Level Low Bank
Question Number:
44 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only B
K/A 0000262450 QUESTION Given the following:
The LEVEL HIGH alarm for annunciator 1-2-A5, CC SURGE TANK LEVEL HIGH LOW came in a few minutes ago when Unit 2 started a second CC pump for a test.
A Safety Injection has subsequently occurred on Unit 1.
While checking the Component Cooling pumps 1A and 1B running, the operator notices annunciator 1-2-A5 CC SURGE TANK LEVEL HIGH LOW is slow flashing.
The Unit 1 Component Cooling Surge Tank level is now DROPPING.
Assuming the level decrease continues, the operator should verify the following CC system response:
a.
Demineralized water auto makeup starts at 50%.
Primary water auto makeup starts at 42%.
b.
Demineralized water auto makeup starts at 55%.
Primary water auto makeup starts at 50%.
c.
Primary water auto makeup starts at 50%.
Demineralized water auto makeup starts at 42%.
d.
Primary water auto makeup starts at 55%.
Demineralized water auto makeup starts at 50%.
ANSWER A
REFERENCE BAR 1-2-A5 Cog Level Low Bank
Question Number:
45 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only B
K/A 000027K101 QUESTION The unit is at 100% power, steady state conditions.
A malfunction on the Master Pressurizer Pressure Controller has caused Reactor Coolant System pressure to deviate 80 psig from its normal setpoint.
This malfunction will result in a change in ?
a.
PRT parameters.
b.
the Overpower Delta T trip setpoints.
c.
VCT level.
d.
Pressurizer Vapor Space temperature.
ANSWER D
REFERENCE ILT Systems LP CH 14, page 2 Cog Level High New
Question Number:
46 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only B
K/A 000038K104 QUESTION Given the following:
The plant experienced a Steam Generator Tube Rupture with Loss of Reactor Coolant.
A degraded ECCS has resulted in the LOSS of core heat transfer from BOTH forced circulation and natural circulation.
If vessel level continues to decrease below the hot leg penetrations and boiling occurs in the core, which of the following describes the core heat transfer mechanism?
a.
Condensation of vapor in the head, which is cooled by fans in containment, and draining back to the core.
b.
Slug flow via the cold legs through the loop seal and flashing across the RUPTURED and FAULTED SG U-tube break.
c.
Condensation of vapor from the bubble at the hot leg side of the INTACT SGs U-tubes which then drains back to the core via the hot legs.
d.
Partial natural circulation flow characterized by liquid pulses flowing from the cold leg over the INTACT SGs U-tubes and into the hot legs.
ANSWER C
REFERENCE Critical Safety Function Analysis Text, Module 2, Lesson 2, page 2-18 Cog Level High Modified
Question Number:
47 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only B
K/A 00WE12K301 QUESTION The WOG Background Document for CA-2.1, UNCONTROLLED DEPRESSURIZATION OF ALL STEAM GENERATORS lists a "High Level Action Summary" of several actions that are to be taken to combat this event.
The action to "Control Feed Flow" is intended to ___(1)___. The action to "Terminate SI Flow" is intended to ___(2)___. Overall the main goal during this event is maintaining ___(3)___.
a.
(1) prevent overfilling the steam generators (2) conserve RWST inventory for Containment Spray usage (3) Containment Integrity b.
(1) minimize further RCS cooldown (2) prevent repressurization of the RCS (3) RCS integrity c.
(1) maintain steam generator levels (2) allow primary and secondary pressures to equalize (3) an adequate heat sink for decay heat removal d.
(1) maintain a thermal stratification layer in the steam generators (2) minimize boron plate out on heat transfer surfaces (3) integrity of the steam generator U-tubes ANSWER B
REFERENCE WOG Background Document for ECA-2.1, pages 3, 17-20 Cog Level High New
Question Number:
48 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only B
K/A 000054K303 QUESTION Should a loss of Main Feedwater occur, proper Steam Generator levels can be maintained by starting the Aux Feedwater Pump(s) and controlling flow via the AF005s, the AF Pump Discharge Flow Control Valves. Depending on plant status, the flow control valves may need to be positioned from various locations such as the Main Control Board (MCB) potentiometer, the Remote Shutdown Panel (RSP) potentiometer, or locally.
The methodology to control flow is different for each because:
When controlled from the MCB potentiometer, AF005 positioning is based on _____(1)_____;
when controlled from the RSP potentiometer, AF005 positioning is based on _____(2)______;
and when controlled locally, a handwheel allows the operator to force the valve ___(3)____
upon failing the Instrument Air supply.
a.
(1) 0 to 100% loop flow (2) 0 to 100% valve position (3) closed b.
(1) 0 to 100% loop flow (2) 0 to 100% valve position (3) open c.
(1) 0 to 100% valve position (2) 0 to 100% loop flow (3) open d.
(1) 0 to 100% valve position (2) 0 to 100% loop flow (3) closed ANSWER A
REFERENCE ILT Systems LP Ch 26, pages 32-33 Cog Level Low Bank
Question Number:
49 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only B
K/A 0000552450 QUESTION 1 BCA-0.0, LOSS OF ALL AC POWER is in progress.
The crew is performing the step to crosstie Bus 141 to Bus 241.
The following breakers have been placed in PULL OUT:
- ACB 1411, the Non-ESF bus tie
- ACB 1412, the SAT feed
- ACB 1414, the Reserve feed Which ONE of the following annunciators COULD be LIT and still allow Bus 141 to be crosstied:
a.
1-21-A7, BUS 141 FD BRKR 1412 TRIP b.
1-21-C7, BUS 141 OVERLOAD OR VOLT LOW c.
1-21-B8, BRKR 1414 CROSS-TIE OVERCURRENT d.
1-21-B9, DG 1A OVERLOAD ANSWER B
REFERENCE BCA-0.0, step 9 Cog Level High New
Question Number:
50 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only B
K/A 000056A131 QUESTION Given the following:
Unit 1 has experienced a SAT fault that resulted in a Loss of Offsite Power (LOOP).
Unit 1 is in Mode 3 at 557 deg F and 2235 psig.
1BOA ELEC-4, LOSS OF OFFSITE POWER is being performed.
Attachment C, RESTORATION OF RCS PRESSURE CONTROL is being performed to restore PZR Heaters.
(Assuming NO jumpers were used to defeat interlocks)
Which of the following describes an alignment that would energize a PZR Backup Heater Group:
Bus 143 crosstied to bus 141 that is energized by ___(1)___.
Closed associated 4KV heater transformer high and low side breakers.
Heater group contactor control switch position of ___(2)___.
a.
(1) 1A D/G (2) ON b.
(1) Bus 241 (2) ON c.
(1) 1A D/G (2) AUTO d.
(1)Bus 241 (2) AUTO ANSWER A
REFERENCE ILT Systems Ch 14 pages 8-9 ILT Systems Ch 4 page 89 BOA ELEC-4, pages 8 & 24 Cog Level High New
Question Number:
51 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only B
K/A 000057A204 QUESTION Given:
Unit 1 is in Mode 3 at 557 deg F.
Annunciator 1-21-E10 "125V DC PNL 111/113 VOLT LOW" alarms.
Annunciator 1-4-A5 "BUS 111 INVERTER TROUBLE" alarms.
Annunciator 1-4-C5 "BUS 113 INVERTER TROUBLE" alarms.
Power Range Channel N-43 Drawer is dark (Deenergized).
Which of the following is indicated by the above?
a.
DC bus 113 is deenergized; only instrument bus 113 is deenergized.
b.
DC bus 113 is deenergized; instrument bus 111 and 113 are deenergized.
c.
DC bus 111 is deenergized; instrument bus 111 and 113 are deenergized.
d.
DC bus 111 is deenergized; only instrument bus 111 is deenergized.
ANSWER A
REFERENCE BAR 1-21-E10 BAR 1-4-A5 and C5 1BOA ELEC-2, page 1 Symptoms or Entry Conditions for loss of an instrument bus.
Horse Note I&C-5 Cog Level High Bank
Question Number:
52 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only B
K/A 000058A101 QUESTION The AF-2 breaker (125 VDC Feed from Battery) to DC Bus 211 has tripped and will not reclose.
From the below selections, choose which correctly describes the alternate flowpath used to re-energize DC bus 211.
a.
Bus 141 to 131X, thru battery charger 111, thru bus 211 crosstie feed breaker.
b.
Bus 242 to 232X, thru battery charger 212 to battery and DC bus 212, thru bus 212 crosstie breaker, thru bus 211 crosstie breaker.
c.
Bus 241 to 231X to 231X2, thru bus 211 inverter to DC bus 211.
d.
Bus 141 to 131X, thru battery charger 111 to battery and DC bus 111, thru bus 111 crosstie breaker, thru bus 211 crosstie breaker.
ANSWER D
REFERENCE Horsenote AC-7 Cog Level Low Bank
Question Number:
53 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only B
K/A 000062K303 QUESTION Given the following:
1BOA PRI-7, ESSENTIAL SERVICE WATER MALFUNCTION is in progress.
Attachment A is being used to perform a SX system crosstie between the units.
The procedural direction is to verify/open the respective RCFC SX Supply and Return valves, 1SX016_ and 1SX027_, prior to starting the standby SX pump.
The reason for having these valves open is ?
a.
to ensure a flowpath is available for containment chiller cooling.
b.
that they provide the crosstie flowpath.
c.
that they are part of the starting interlocks for the pump.
d.
to ensure a flowpath is available for Diesel Generator cooling.
ANSWER C
REFERENCE ILT Systems LP Ch 20 page 33 Cog Level Low New
Question Number:
54 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only B
K/A 0000652123 QUESTION Given the following Unit 2 plant conditions:
Unit 2 was in Mode 3 at 2235 psig and 557 deg F with primary system and secondary system parameters being controlled automatically.
The Instrument Air (IA) Header became depressurized and the crew entered 0/1/2BOA SEC-4, LOSS OF INSTRUMENT AIR.
During the loss of IA, the Unit 2 operators performed actions directed by 2BOA SEC-4.
The IA problem has been corrected and IA Header pressure is now 50 psig and INCREASING.
Which of the following MCB controllers should be placed in MANUAL with 0% demand to prevent an undesired transient?
a.
2AF005A thru H, Aux Feedwater Flow Controllers b.
2RY455B and C, PZR Spray Valve Controllers c.
2CC130A/B, Letdown Heat Exchanger Temperature Control Valve Controller d.
2CV121, Centrifugal Charging Pump Flow Controller ANSWER B
REFERENCE 1/2 BOA SEC-4 pages 2 thru 6 Cog Level High Modified
Question Number:
55 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only B
K/A 00WE11K201 QUESTION The following conditions exist on Unit 1:
A loss of coolant accident has occurred.
RWST Level is 35% and DECREASING.
1BCA-1.1, LOSS OF EMERGENCY COOLANT RECIRCULATION is in progress.
1B RH pump has TRIPPED on overcurrent.
Attempts are being made to establish Cold Leg Recirculation capability.
SI has been RESET.
The NSO is questioning the ECCS valve alignment.
Which of the following is PREVENTING 1SI8811A, Train A SI Recirc Sump Isolation valve from being MANUALLY OPENED?
a.
1SI8812A, Train A RWST to RH Suction valve is CLOSED.
b.
1SI8812A, Train A RWST to RH Suction valve is OPEN.
c.
1CS001A, Train A RWST to CS Suction valve is CLOSED.
d.
1CS009A, Train A Containment Recirc Sump to CS Suction valve is OPEN.
ANSWER B
REFERENCE ILT Systems LP Ch 18, page 11 Cog Level Low Bank
Question Number:
56 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only B
K/A 00WE052449 QUESTION Given the following:
1BFR-H.1, RESPONSE TO LOSS OF SECONDARY HEAT SINK is in progress.
The Operators are performing step 4, trying to establish Aux Feedwater to at least one S/G.
Per the Operator Action Summary (OAS) page, which one of the following conditions would result in the need to jump ahead in the procedure to initiate Bleed and Feed?
a.
Low PZR pressure b.
Low S/G Narrow Range level c.
NO Centrifugal Charging pumps available d.
Increasing loop Delta-T ANSWER C
REFERENCE 1BFR-H.1 OAS page Cog Level Low New
Question Number:
57 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only B
K/A 000036A103 QUESTION Per 2BOA REFUEL-2, REFUELING CAVITY OR SPENT FUEL POOL LOSS, in order to initiate evacuation of non-essential personnel from affected areas:
_____(1)_____ if the affected area is the containment (CNMT).
_____(2)_____ if the affected area is the Fuel Handling Building (FHB).
a.
(1) Actuate the CNMT evacuation alarm from the MCB and make an announcement over the plant page (2) Make an announcement over the plant page b.
(1) Make an announcement over the plant page (2) Actuate the FHB evacuation alarm from the MCB and make an announcement over the plant page c.
(1) Insure the CNMT evacuation alarm has automatically sounded and contact the CNMT Coordinator to initiate the evacuation.
(2) Insure the FHB evacuation alarm has automatically sounded and make an announcement over the plant page.
d.
(1) Insure the CNMT evacuation alarm has automatically sounded and make an announcement over the plant page (2) Insure the FHB evacuation alarm has automatically sounded and contact the Fuel Handling Supervisor to initiate the evacuation.
ANSWER A
REFERENCE BOA REFUEL-2 step 1a Cog Level Low New
Question Number:
58 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only B
K/A 0000372132 QUESTION Given the following plant conditions:
Unit 1 is at full power.
Based on primary and secondary plant indication, 1BOA SEC-8, STEAM GENERATOR TUBE LEAK, has been entered.
1CV121, the CV Pumps Discharge Header Flow Control Valve, and 1CV182, the Seal Injection Flow Control Valve, have been throttled full open.
Pressurizer level is still DROPPING.
Prior to manually initiating a reactor trip and SI, which of the following actions is acceptable in an attempt to maintain Pressurizer level?
a.
Start a Second Charging Pump.
b.
Establish 75 GPM Letdown.
c.
Begin a Unit Load Reduction.
d.
Open 1SI8801A and B, the Cold Leg Injection Valves.
ANSWER B
REFERENCE BOA SEC-8 step 1b RNO (page 2)
Cog Level Low Modified
Question Number:
59 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only B
K/A 000059K201 QUESTION Which of the following Process Radiation Monitors has an INTERLOCK FUNCTION designed to prevent an accidental offsite liquid radwaste release?
a.
0RE-PR010, the Station Blowdown Rad Monitor b.
1RE-PR002, the RCFC 1A and 1C SX Outlet Rad Monitor c.
1RE-PR011, the Containment Atmosphere Rad Monitor d.
0RE-PR041, the Condensate Polisher Sump Discharge Rad Monitor ANSWER D
REFERENCE TRM Table 3.11.a, pages 3.11.a-9 thru 11 or ILT Systems Chapter 49 LP, page 36 Cog Level Low New
Question Number:
60 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only B
K/A 000068K314 QUESTION Given the following:
Both units were manually tripped from mode 1.
The Control Room has been evacuated, 0/1/2 BOA PRI-5, CONTROL ROOM INACCESSIBILITY procedures have been entered and local control has been established from the respective Units Remote Shutdown Panel (RSP).
It has been decided to place both units in Mode 4.
To prevent an automatic SI, it will be necessary to block the ?
a.
Steamline Low Pressure SI by depressing the block pushbuttons at the RSP prior to Main Steamline pressure reaching 640 psig.
b.
Pressurizer Low Pressure SI by depressing the block pushbutton at the RSP prior to Pressurizer pressure reaching 1930 psig.
c.
Steamline Low Pressure SI by placing jumpers in the SSPS cabinets prior to Main Steamline pressure reaching 640 psig.
d.
Pressurizer Low Pressure SI by placing jumpers in the SSPS cabinets prior to Pressurizer pressure reaching 1930 psig.
ANSWER C
REFERENCE BOA PRI-5 pages 28-30, 61-62 ILT Systems LP Ch 61 pages 15-16 Cog Level Low New
Question Number:
61 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only B
K/A 0000742225 QUESTION Meeting LCO 3.5.2, ECCS-OPERATING, helps to ensure the ECCS Acceptance Criteria (10 CFR 50.46) of 2200 deg F peak cladding temperature will NOT be exceeded during a LOCA.
The limit of 2200 deg F is selected as this is ?
a.
500 deg F below the clad melt point of 2700 deg F.
b.
1000 deg F below the fuel melt temperature of 3200 deg F.
c.
the temperature above which thermal conductivity of the clad decreases significantly.
d.
the temperature above which the zircaloy-water reaction is greatly accelerated.
ANSWER D
REFERENCE ILT Systems LP Ch 58, pages 3-4 ILT Fundamentals LP Ch PD1 TS Bases B 3.5.2 page 4 Cog Level Low Bank
Question Number:
62 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only B
K/A 00WE02K101 QUESTION Given the following plant conditions for Unit 1:
A LOCA has occurred.
The crew manually tripped the Reactor, manually actuated Safety Injection, entered and performed 1BEP-0, REACTOR TRIP AND SAFETY INJECTION.
A transition was made to 1BEP-1, LOSS OF REACTOR OR SECONDARY COOLANT.
The crew is now in 1BEP ES-1.1, SI TERMINATION, preparing to perform the step to REALIGN CENT CHG PUMPS(s) when the following was observed:
RCS pressure: 1250 psig SI Pump 1A flow: 0 gpm SI Pump 1B flow: 150 gpm What is the status of the ECCS?
a.
SI Pump 1A flow is LOWER than expected and SI Pump 1B flow is HIGHER than expected.
b.
SI Pump 1A flow is LOWER than expected and SI Pump 1B flow is AS expected.
c.
SI Pump 1A is indicating the expected flow rate with its miniflow valve OPEN. SI Pump 1B is indicating the expected flow rate with its miniflow valve CLOSED.
d.
BOTH SI Pumps are reading LESS THAN the expected flow.
ANSWER D
REFERENCE ILT Systems LP Ch 58, page 9-10 Cog Level High Bank
Question Number:
63 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only B
K/A 00WE13K303 QUESTION 1BFR-H.2, RESPONSE TO STEAM GENERATOR OVERPRESSURE, contains a CAUTION:
"If AFFECTED SG narrow range level increases to greater than 93% (81% ADVERSE CNMT),
steam should NOT be released from the AFFECTED SG(s)".
WHICH of the following is the reason for this caution?
a.
To prevent moisture separator damage due to two phase flow from an overfilled steam generator.
b.
To prevent damage to valves and piping from water hammer if steam is released from the steam generator.
c.
Steam flow indication would be inaccurate due to moisture collection in steam flow transmitters.
d.
Steam flow would have a high moisture content and could cause inaccurate main steam line radiation readings.
ANSWER B
REFERENCE WOG Background Document for Caution prior to step 4 of FR-H.2 (page 16 of Document)
Cog Level Low Bank
Question Number:
64 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only B
K/A 00WE15A103 QUESTION During various Design Basis Accidents (DBAs), water is collected in the containment sump so it is available for long term core and/or containment cooling via the emergency core cooling or containment spray recirculation system.
During a major accident, indications of water addition to the containment water volume from which of the following sources is UNEXPECTED per BFR-Z.2, RESPOND TO CONTAINMENT FLOODING?
a.
Condensate Storage Tank b.
Safety Injection Accumulators c.
Primary Water Storage Tank d.
Refueling Water Storage Tank ANSWER C
REFERENCE WOG Background Document for FR-Z.2, page 2 & 8 Cog Level Low New
Question Number:
65 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only B
K/A 00WE09A201 QUESTION Assume the following plant conditions exist on Unit 1:
The unit tripped from 100% power when a switchyard failure caused a loss of offsite power.
1BEP ES-0.2, NATURAL CIRCULATION COOLDOWN is in progress to perform a natural circulation cooldown and depressurization of the RCS.
For which of the following situations should 1BEP ES-0.3, NATURAL CIRCULATION COOLDOWN WITH STEAM VOID IN VESSEL (WITH RVLIS) be used instead of 1BEP ES-0.2?
a.
ALL CRDM Exhaust and Booster Fans CANNOT be run.
b.
Normal Pressurizer Spray is unavailable for use in depressurizing the RCS.
c.
The rate of the cooldown and depressurization would form a steam void in the vessel.
d.
The SI Accumulators are unable to be isolated.
ANSWER C
REFERENCE 1BEP ES-0.2 Note at top of page 8 Cog Level Low New
Question Number:
66 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only B
K/A 1940012111 QUESTION Consider each of the following situations individually. Assume Mode 1 operation.
Which of the following has a Completion Time of "Immediately" for the Tech Spec Required Action of "Initiate action to restore one train to OPERABLE status"?
a.
2 ECCS Trains are inoperable.
b.
2 AF Trains are inoperable.
c.
2 CS Trains are inoperable.
d.
2 VC Filtration Trains are inoperable.
ANSWER B
REFERENCE LCO 3.7.5 Condition C on page 3.7.5-1 Cog Level Low New
Question Number:
67 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only B
K/A 1940012121 QUESTION An NSO has been tasked to perform an activity that involves directing NLOs in the field to manipulate equipment. Which of the following is the expected method of ensuring the most recent revision of the procedure is being used to perform the activity?
Use the ?
a.
NLO's field copy.
b.
Electronic Central Files (ECF) copy.
c.
Electronic Document Management System (EDMS) copy.
d.
spare copy that was printed out the last time the task was performed.
ANSWER C
REFERENCE HU-AA-104-101, 'Procedure Use and Adherence", page 2.
Cog Level Low New
Question Number:
68 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only B
K/A 1940012132 QUESTION BGP 100-3, POWER ASCENSION has a Turbine Generator Limitation and Action to ensure that, when within 5% of a power limit, MW OUT is to be selected at the DEHC panel. What is the basis for the direction of operating with MW OUT?
Operating in MW OUT mode REDUCES ?
a.
turbine Governor Valve oscillations that would occur from changing main steam pressure.
b.
turbine load changes from grid frequency perturbations.
c.
reactor power changes since generator output is held constant.
d.
the chances of exceeding power limits due to degrading secondary efficiency.
ANSWER D
REFERENCE ILT Systems LP Ch 37a, page 22 Cog Level High New
Question Number:
69 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only B
K/A 1940012225 QUESTION The limitation for starting an RCP with RCS cold leg temperatures less than 350 deg F is that the temperature in the Steam Generators must be less than 50 deg F above RCS temperature.
What is the Bases for this limitation?
a.
Prevents an overpressure event of the RCS.
b.
Prevents excessive cooldown rate of the Steam Generators.
c.
Maintains RCP seal parameters within normal operating range.
d.
Ensures sufficient net positive suction head at suction of the RCP.
ANSWER A
REFERENCE Tech Spec Bases for Note 2 in LCO 3.4.6 (page B 3.4.6-3)
Cog Level Low Bank
Question Number:
70 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only B
K/A 1940012234 QUESTION An Estimated Critical Condition (ECC) has been calculated for a Beginning of Life (BOL),
Negative Moderator Temperature Coefficient (- MTC) reactor startup that is to be performed 5 hours5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br /> after a trip from a 60 day full power run.
Which of the following events or conditions will result in the ACTUAL critical control rod height being LOWER than the PREDICTED control rod height in the ECC? (Consider each item separately) a.
The startup is delayed 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> due to a passing thunderstorm.
b.
The Nuclear Engineer used the EOL Integrated Rod Worth Curve instead of the BOL Curve for the ECC calculation.
c.
A new boron sample shows a current boron concentration 20 ppm higher than that used in the ECC calculation.
d.
Main Steam Header pressure is decreased by 100 psi just prior to criticality.
ANSWER D
REFERENCE BCB Fig 8c for distractor A BCB Fig 2 for BOL & EOL for distractor B BCB Table 1-5 for distractor C BCB Fig 5A for answer D Cog Level High Bank
Question Number:
71 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only B
K/A 1940012203 QUESTION 2BGP 100-3, POWER ASCENSION for Unit 2 has a step to open 2FW039A, B, C, and D at 80% power.
Why does 1BGP 100-3 POWER ASCENSION for Unit 1 NOT direct a similar action?
1FW039A, B, C, and D are ?
a.
opened earlier in the power ascension when feedwater control is switched to the Feed Reg Valves.
b.
only open at low power when it is necessary to close the respective 1FW009 valve.
c.
NOT allowed to be opened while in Mode 1.
d.
normally open when tempering flow is required.
ANSWER B
REFERENCE 1BGP 100-3, step F.40 (pages 51-53)
Cog Level Low New
Question Number:
72 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only B
K/A 1940012302 QUESTION The Total Effective Dose Equivalent (TEDE) is which of the following?
The sum of the ?
a.
Deep Dose Equivalent (DDE) and the Committed Dose Equivalent (CDE).
b.
Deep Dose Equivalent (DDE) and the Committed Effective Dose Equivalent (CEDE).
c.
Committed Effective Dose Equivalent (CEDE) and the Eye (lens) Dose Equivalent (LDE).
d.
Committed Dose Equivalent (CDE) and the Eye (lens) Dose Equivalent (LDE).
ANSWER B
REFERENCE Byron Outage Handbook page Cog Level Low Bank
Question Number:
73 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only B
K/A 1940012304 QUESTION The NRC Legal Radiation Exposure limit for an Adult Occupational Worker at Byron Station is
___(1)___ TEDE. In order to PROTECT VALUABLE PROPERTY should the site enter the Emergency Plan due to an accident event, and with proper authorization, an Emergency Worker could receive up to ___(2)___ TEDE.
a.
(1) 5 Rem/year (2) 10 Rem b.
(1) 5 Rem/year (2) 25 Rem c.
(1) 2 Rem/year (2) 10 Rem d.
(1) 2 Rem/year (2) 25 Rem ANSWER A
REFERENCE RP-AA-203, page 2 and page 7 Cog Level Low New
Question Number:
74 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only B
K/A 1940012402 QUESTION While operating at 50% power, a scan of the Main Control Board reveals the following:
Reactor Power = 50%
RCS Tavg = 575 deg F PZR Press. = 1860 psig PZR Level = 40%
Rod Control = MANUAL Which ONE of the following is the correct procedure to enter based on the above information?
a.
BOA PRI-1, EXCESSIVE PRIMARY PLANT LEAKAGE.
b.
BOA PRI-12, UNCONTROLLED DILUTION.
c.
BEP-1, LOSS OF REACTOR OR SECONDARY COOLANT.
d.
BEP-0, REACTOR TRIP OR SAFETY INJECTION.
ANSWER D
REFERENCE BEP-0, page 1, SYMPTOMS OR ENTRY CONDITIONS Cog Level High Bank
Question Number:
75 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only B
K/A 1940012419 QUESTION Which ONE of the following statements completes the following sentence?
Concerning usage rules of LOW-LEVEL STEPS in Emergency Procedures, _________ are used to signify those steps that must all be completed, but can be in any order.
a.
closed bullets b.
lower case letters c.
open bullets d.
diamonds ANSWER A
REFERENCE BAP 1310-10, HU-AA-104-101, Procedure Use and Adherence, Byron Addendum" page 13 Cog Level Low New
Question Number:
76 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only S
K/A 1940012114 QUESTION For which of the following events or conditions must the Plant Manager be notified according to OP-AA-106-101, Significant Event Reporting?
a.
Failure of the Safety Parameter Data System (SPDS).
b.
A contractor alarmed the portal monitor while exiting the Aux Building.
c.
Entry into Action Level I for Secondary Chemistry.
d.
Failure of an acceptance criteria while performing the SSPS Bi-monthly BOSR.
ANSWER D
REFERENCE OP-AA-106-101, Attachment 1 TS LCO 3.3.2 Condition C Cog Level High modified
Question Number:
77 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only S
K/A 1940012229 QUESTION Given the following plant conditions:
Unit 2 is reloading fuel following a complete core offload Due to an unexpected condition, core alterations were suspended by the Fuel Handling Supervisor SRO(L)
The condition has now been corrected Evaluate each of the listed conditions below separately.
If it is desired to resume core alterations, in accordance with BAP 370-3, ADMINISTRATIVE CONTROL DURING REFUELING, which condition would NOT require concurrence from the Shift Manager and Fuel Handling Supervisor SRO(L)?
a.
ONE of the source range channels was indicating 1 count per second.
b.
There was an unexpected increase by a factor of 2 on ALL source range channels.
c.
There was an unexpected increase by a factor of 5 on ONE source range channel.
d.
An inverse count rate ratio extrapolation indicated criticality could occur with the addition of the next few fuel assemblies.
ANSWER A
REFERENCE BAP 370-3 rev 31, Administrative Control During Fuel Handling, step C.2.ee.
Cog Level Low New
Question Number:
78 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only S
K/A 1940012209 QUESTION Given the following Unit 1 plant conditions:
The reactor vessel head has just been removed Refueling cavity water level was raised to 24.5 feet above the vessel flange using the 1B RH pump.
1A RH pump is aligned for shutdown cooling 1FH001, Fuel Transfer Tube Isolation Valve, is closed There is a Clearance Order waiting to take 1B RH pump out of service for 1 shift for a scheduled test Considering Tech Specs and the Shutdown Safety Management Program Key Safety Functions:
If the 1B RH pump is taken out of service NOW ?
a.
NEITHER Tech Specs NOR the Key Safety Functions will be impacted.
b.
The LCO Required Action must be entered AND the Key Safety Functions will be degraded.
c.
Tech Specs is NOT impacted but the Key Safety Functions will be degraded.
d.
The LCO Required Action must be entered but the Key Safety Functions will NOT be impacted.
ANSWER C
REFERENCE NSP OU-AP-104, page 63 TS page 3.9.5-1 Cog Level High New
Question Number:
79 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only S
K/A 1940012309 QUESTION Given the following:
Unit-2 is at full power.
Due to a desire to lower containment internal pressure, a release package has been developed to permit a Unit-2 Containment Release.
While performing the Source/Channel Check BOSR for 2RE-PR001J, the U-2 Containment Purge Effluent Radiation Monitor, a failure resulted and the Rad Monitor was declared INOPERABLE.
In order to meet the Radioactive Effluent Controls Program (Tech Spec Section 5.5.4) requirements, the U-2 Containment Release ?
a.
can NOT be performed until 2RE-PR001J, U-2 Containment Purge Effluent Rad Monitor, has been restored to OPERABLE and functioning.
b.
can be performed as long as 2RE-PR028, the U-2 Aux Building Vent Stack Effluent Rad Monitor, is OPERABLE and functioning.
c.
can be performed as long as 2RE-PR11J, the U-2 Containment Atmosphere Rad Monitor, is OPERABLE and functioning.
d.
can be performed as long as both 2RE-AR11 and 12J, the U-2 Containment Fuel Handling Incident Rad Monitors, are OPERABLE and functioning.
ANSWER B
REFERENCE BOL 11.b page 5 Cond D and note 2, page 6 Cond F and note 2, Attachment A page 11 BRP 5820-12 Attach B page 12 Cog Level High New
Question Number:
80 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only S
K/A 1940012311 QUESTION The Unit has suffered a Steam Generator Tube Rupture (SGTR) and the crew has stabilized the plant in accordance with BEP-3, STEAM GENERATOR TUBE RUPTURE.
If the goal is to use the recovery procedure that will MOST limit contamination spread and offsite radiological releases, the Unit Supervisor should select _________________________
to perform the subsequent ruptured SG cooldown and depressurization.
a.
BEP ES-3.1, Post-SGTR Cooldown Using Backfill b.
BEP ES-3.2, Post-SGTR Cooldown Using Blowdown c.
BEP ES-3.3, Post-SGTR Cooldown Using Steam Dump d.
BFR H.3, Response to Steam Generator High Level ANSWER A
REFERENCE WOG Background for EP-3, Section 3.2, page 55-56 Cog Level High New
Question Number:
81 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only S
K/A 1940012408 QUESTION BFR P.1, RESPONSE TO IMMINENT PRESSURIZED THERMAL SHOCK CONDITION would be entered immediately upon encountering a Status Tree Red Conditon for RCS INTEGRITY even if ________(1)________ is currently being performed _________(2)_________.
a.
(1) BCA-0.0, LOSS OF ALL AC POWER (2) to reenergize a 4KV ESF Bus b.
(1) step 1 of BEP ES-1.3, TRANSFER TO COLD LEG RECIRCULATION (2) to establish CC flow to the RH Heat Exchangers c.
(1) BEP-1, LOSS OF REACTOR OR SECONDARY COOLANT (2) due to a large break LOCA d.
(1) a cooldown and depressurization of the RCS per BEP-3, STEAM GENERATOR TUBE RUPTURE (2) without RCPs running ANSWER C
REFERENCE BAP 1310-10, page 19 BFR-P.1, page 2, step 1 Cog Level Low New
Question Number:
82 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only S
K/A 1940012450 QUESTION Following a Unit 1 reactor trip and SI, the Unit Supervisor is directing performance of 1BEP-0, REACTOR TRIP OR SAFETY INJECTION.
Annunciator 1-3-A7, AF PUMP SUCTION PRESSURE LOW, alarms.
Per the Operator Action Summary (OAS) page, in response to this alarm the Unit Supervisor could ____(1)____. This action could be taken because ____(2)____.
a.
(1) make a transition to 1BFR-H.1, RESPONSE TO LOSS OF SECONDARY HEAT SINK (2) this is the alarm setpoint for a trip of BOTH AF Pumps on low suction pressure b.
(1) direct board operators to verify/open the SX to AF Pump suction valves (1SX006A/B, 1SX017A/B)
(2) this is the alarm setpoint for the swapover to SX supply on low suction pressure c.
(1) direct a depressurization of the intact Steam Generators (SGs)
(2) this would reduce the pressure drop across the running AF Pumps d.
(1) direct initiation of makeup to the Unit 1 Condensate Storage Tank (CST)
(2) raising CST level will increase BOTH AF Pumps suction pressure ANSWER D
REFERENCE 1BEP-0, OPERATOR ACTION
SUMMARY
page BAR 1-3-A7 BAR 1-3-E7 Cog Level High New
Question Number:
83 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only S
K/A 015000A203 QUESTION Given the following:
The crew is performing 2BOA SEC-1, SECONDARY PUMP TRIP due to a Main Feedwater Pump trip from 92% power during an End of Life (EOL) Coastdown prior to refueling.
The standby Main Feedwater pump was unavailable and the necessary runback has resulted in a Xenon oscillation that is causing an Axial Flux (Delta I) oscillation.
Delta I is currently +10% and getting more POSITIVE.
The current Delta I trend will result in a reduction of the ____(1)____ reactor trip setpoint; and per 2BGP 100-8, GENERIC REACTOR CONTROL GUIDANCE, the Unit Supervisor must evaluate directing further power changes as ____(2)_____ NOW will make the Delta I oscillation WORSE.
a.
(1) Over Temperature Delta T (2) DECREASING turbine power b.
(1) Over Power Delta T (2) DECREASING turbine power c.
(1) Over Temperature Delta T (2) INCREASING turbine power d.
(1) Over Power Delta T (2) INCREASING turbine power ANSWER A
REFERENCE BAR 2-11-B4, OT DELTA T RX TRIP 2BGP 100-8, page 5 Cog Level High New
Question Number:
84 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only S
K/A 072000K201 QUESTION The following Unit 1 pertinent plant conditions exist:
Reactor power: 90%
All Radiation Monitors are currently OPERABLE.
Instrument Maintenance has requested that breaker 131X1 L2-17 for 1RT-AR022, Main Steamline Rad Monitor be opened to allow troubleshooting.
If breaker 131X1 L2-17 were opened the Unit Supervisor would ?
a.
need to enter a LCOAR because this would render the RM-11 communications loop INOPERABLE.
b.
NOT need to enter a LCOAR because Main Steam Line Radiation Monitor (1AR023A, B, C, D) will still be OPERABLE.
c.
need to enter a LCOAR because both of the Main Steam Line Radiation Monitors (1AR022A, B, C, D and 1AR023A, B, C, D) will be INOPERABLE.
d.
NOT need to enter a LCOAR because Main Steam Line Radiation Monitor (1AR022A, B, C, D) will still be OPERABLE.
ANSWER B
REFERENCE BOP AR/PR-2T1, 2T2, 5T1 (cross reference), Tech Spec Table 3.3.3-1 Cog Level High Modified
Question Number:
85 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only S
K/A 008000A201 QUESTION The following conditions exist on Unit 1:
Unit 1 is at 100% power.
The running 1B CC pump just tripped.
While investigating it is determined that Unit 1 CC Surge Tank level is 10% and decreasing.
Which of the following directions should the Unit Supervisor give to the NSOs FIRST?
a.
Per 1BOA PRI-6, COMPONENT COOLING MALFUNCTION, isolate letdown and place excess letdown in service to prevent overheating the letdown demineralizers.
b.
Per BAR 1-2-B5, CC PUMP DSCH PRESS LOW, verify/start the standby CC pump.
c.
Per BAR 1-2-A5, CC SURGE TANK LEVEL HIGH LOW, notify Chemistry and Rad Protection of potential outleakage on the CC System.
d.
Per 1BOA PRI-6, COMPONENT COOLING MALFUNCTION, place all CC pumps in Pull Out, trip the reactor, and trip the RCPs.
ANSWER D
REFERENCE BOA PRI-6, page 2, step 1, and page 10 (Attachment A, step1)
Cog Level High New
Question Number:
86 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only S
K/A 0100002132 QUESTION Given the following plant conditions:
Unit 2 is stable in Mode 3 at 500 psig and 360 deg F.
Pressurizer PORVs are in ARM LOW TEMP for LTOP.
The IMs wish to calibrate a Wide Range RCS Tcold RTD that will involve ranging the instrument from 0 to 700 deg F.
The Unit Supervisor is evaluating Pressurizer PORV LTOP response to determine if this calibration activity should be allowed.
In order to prevent an inadvertent LTOP actuation as the Wide Range RCS Tcold RTD decreases toward 0 deg F, it will be necessary to disable Pressurizer PORV ________.
Disabling the PORV under the current plant conditions will _____________.
a.
2RY456; NOT require entering the LTOP LCOAR b.
2RY455A; NOT require entering the LTOP LCOAR c.
2RY455A; require entering the LTOP LCOAR d.
2RY456; require entering the LTOP LCOAR ANSWER A
REFERENCE U-2 PTLR Figure 2.3 and Table 2.2 (pages 7 & 8)
LTOP LCO 3.4.12 ILT Systems LP Ch 14, page 27 Cog Level High Modified
Question Number:
87 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only S
K/A 012000A202 QUESTION Given the following:
Unit 2 is at 100% power While exiting the Train B SSPS Bi-Monthly BOSR, the power supply to the 2B SSPS Train Output Bay fails and can NOT be restored.
In regard to the Train 2B Reactor Trip System (RTS) Instrumentation Tech Spec LCO 3.3.1, and Engineered Safety Features Actuation System (ESFAS) Instrumentation Tech Spec 3.3.2:
a.
BOTH RTS and ESFAS are still OPERABLE; therefore NO Required Actions are necessary.
b.
RTS is still OPERABLE; ESFAS is NOT OPERABLE and the Required Actions for LCO 3.3.2 must be followed.
c.
NEITHER RTS NOR ESFAS is OPERABLE; the Required Actions for BOTH LCOs 3.3.1 and 3.3.2 must be followed.
d.
RTS is NOT OPERABLE and the Required Actions for LCO 3.3.1 must be followed; ESFAS is still OPERABLE.
ANSWER B
REFERENCE ILT Systems LP Ch 60a, page 48, TP-12 LCO TABLE 3.3.1-1 page 4 of 6, LCO Table 3.3.2-1 page 1 of 6 Cog Level High New
Question Number:
88 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only S
K/A 064000A102 QUESTION The Tech Spec MINIMUM stored diesel fuel oil requirement for each Diesel Generator is
__________ gallons.
The BASES for this minimum volume is to have a sufficient fuel oil supply for ___ days of post accident load operation of a Diesel Generator.
a.
50,000; 4 b.
44,000; 7 c.
50,000; 7 d.
44,000; 4 ANSWER B
REFERENCE SR 3.8.3.1 in LCO 3.8.3 page 3.8.3-2 TS Bases page B 3.8.3-2 Cog Level Low New
Question Number:
89 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only S
K/A 000005A105 QUESTION Given the following:
Unit 2 tripped from Mode 1.
The DRPI Rod Bottom (RB) lite is NOT lit for one control rod Annunciator 2-10-D6, ROD CONT NON-URGENT FAILURE is alarming.
Checking the SER point determines the alarm is associated with DRPI.
Per Tech Specs, in regard to its ability to determine if there currently is a stuck control rod, DRPI is ?
a.
OPERABLE because the Shutdown Margin calculations assume one control rod is stuck out.
b.
INOPERABLE because the lack of the Rod Bottom lite indicates DRPI is NOT functioning for that control rod.
c.
OPERABLE because DRPI can still detect the position of each control rod within plus or minus 12 steps.
d.
INOPERABLE because DRPI now does NOT have sufficient accuracy to detect whether that control rod is stuck.
ANSWER C
REFERENCE Tech Spec Bases for Rod Position Indication page B 3.1.7-3 TLCO 3.1.g Cog Level High New
Question Number:
90 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only S
K/A 000060K102 QUESTION Which ONE of the following represents the MAXIMUM activity allowed in a gas decay tank, and the BASES for this value?
a.
5,000 Curies, to ensure offsite dose will be limited to a small fraction of the 10CFR100 limits in the event of an inadvertent release of the tank contents.
b.
50,000 Curies, to limit site boundary dose to 0.5 rem in the event of an inadvertent release of the tank contents.
c.
5,000 Curies, to limit site boundary dose to 0.5 rem in the event of an inadvertent release of the tank contents.
d.
50,000 Curies, to ensure offsite dose will be limited to a small fraction of the 10CFR100 limits in the event of an inadvertent release of the tank contents.
ANSWER B
REFERENCE TRM Appendix L, pages 4 & 5 of 7 ILT Systems LP Ch 46, page 19 & 37 Cog Level Low Bank
Question Number:
91 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only S
K/A 000061A206 QUESTION Step 6 of BEP-2, FAULTED STEAM GENERATOR ISOLATION has the crew "CHECK SECONDARY RADIATION".
A NOTE prior to step 6 advises secondary radiation monitors may fail high under certain conditions.
What conditons could fail these radiation monitors; and what UNNECESSARY procedure transitions could result if the note was NOT heeded?
a.
a steam break outside containment; a transition to BEP-3, STEAM GENERATOR TUBE RUPTURE.
b.
a loss of offsite power; a concurrent performance of BOA ELEC-4, LOSS OF OFFSITE POWER.
c.
a steam break inside containment; a transition to BCA--2.1, UNCONTROLLED DEPRESSURIZATION OF ALL STEAM GENERATORS.
d.
a swap from Narrow Range to Wide Range Iconics (SPDS) failing the RM-11; a transition to BEP ES-0.0, REDIAGNOSIS.
ANSWER A
REFERENCE BEP-2 LP note explanation about instruments outside cnmt not being EQ.
Cog Level High New
Question Number:
92 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only S
K/A 00WE01K201 QUESTION Considering each event separately, during which of the following conditions would entry into 1BEP ES-0.0, "Rediagnosis" be allowed?
a.
If a twenty (20) gpm S/G tube leak is detected while performing 1BEP ES-0.2.
"Natural Circulation Cooldown ".
b.
If a RED path is detected in Heat Sink while performing 1BEP-1 "Loss of Reactor Or Secondary Coolant".
c.
If SI is actuated erroneously while performing the actions of 1BEP ES-0.1 "Reactor Trip Recovey".
d.
If a faulted S/G was isolated, then the other 3 S/Gs faulted while performing 1BEP ES-1.1 "SI Termination".
ANSWER D
REFERENCE 1BEP ES-0.0 page 1 Cog Level Low modified
Question Number:
93 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only S
K/A 00WE03A201 QUESTION Given the following:
Unit 1 has tripped and experienced a Safety Injection.
While performing 1BEP ES-1.2 "Post LOCA Cooldown and Depressurization", an ORANGE path condition was noted for the Core Cooling Critical Safety Function.
1BFR-C.2, "Response To Degraded Core Cooling", was entered in response to this condition.
While performing the steps of this procedure, the STA reports a RED path condition exists for the Core Cooling Critical Safety Function, which has an endpoint of BFR-C.1, "Response to Inadequate Core Cooling".
Simultaneously a RED path condition exists for the Containment Critical Safety Function, which has the endpoint of 1BFR-Z.1, "Response To High Containment Pressure."
NO other abnormal condition was noted.
What is the appropriate action?
a.
Stop performing 1BFR-C.2, and immediately transition to 1BFR-Z.1.
b.
Stop performing 1BFR-C.2, and concurrently perform 1BFR-Z.1 AND 1BFR-C.1.
c.
Complete the actions of 1BFR-C.2, and then immediately transition to 1BFR-C.1.
d.
Stop performing 1BFR-C.2, and immediately transition to 1BFR-C.1.
ANSWER D
REFERENCE BAP 1310-10, HU-AA-104-101, Procedure Use and Adherence, Byron Addendum" pages 17 thru 20 Cog Level High bank
Question Number:
94 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only S
K/A 000007A202 QUESTION Unit 1 is at 18% power getting ready to synchronize the main generator to the grid. A Loss of Offsite Power occurs. The following indications are noted immediately:
All Power Range NIS indicated 0%.
IR SUR indication is -0.3 dpm.
All DRPI lights are out.
RTB is CLOSED.
RTA is OPEN.
BYA and BYB are racked out.
RTB remained CLOSED after the operators initiated a manual reactor trip from 1PM05J and 1PM06J.
Which of the following actions should be taken?
a.
Go to 1BFR-S.1, RESPONSE to NUCLEAR POWER GENERATION/ATWS.
b.
Go to 1BFR-S.2, RESPONSE TO LOSS OF CORE SHUTDOWN.
c.
Go to 1BCA-0.0, LOSS of ALL AC POWER.
d.
Continue in 1BEP-0, REACTOR TRIP OR SAFETY INJECTION.
ANSWER D
REFERENCE Step 1 and RNO of 1BEP-0 Cog Level High Bank
Question Number:
95 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only S
K/A 0000082449 QUESTION Given the following:
Unit 2 has tripped from mode 1.
Pressurizer pressure is 2200 psig and decreasing.
The board operators are performing the immediate actions of 2BEP-0, REACTOR TRIP OR SAFETY INJECTION.
From the unit desk, the Unit Supervisor notes annunciator 2-12-B2, PZR PORV OR SAF VLV OPEN alarming and observes the Pressurizer Safety Valve indicator lites are GREEN.
Given this situation, the Unit Supervisor should direct the board operators to ?
a.
manually Safety Inject.
b.
manually close the block valves on the Pressurizer PORVs.
c.
trip the RCPs as soon as RCS pressure drops below 1425 psig.
d.
manually close any open Pressurizer PORV.
ANSWER D
REFERENCE BEP-0, step 24b RNO (page 21), also BOA INST-2 page 10 (step 2a RNO)
Cog Level High New
Question Number:
96 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only S
K/A 000009K323 QUESTION The reason the Reactor Coolant Pumps (RCPs) are required to be manually tripped during the early stages of a small break LOCA is to ?
a.
eliminate RCP heat input into the Reactor Coolant System (RCS).
b.
avoid significant clad heatup should the RCPs trip later in the accident.
c.
avoid RCP impeller damage as dissolved gasses come out of solution at lower pressures.
d.
prevent RCP seal damage during subsequent RCS depressurization.
ANSWER B
REFERENCE ILT Simulator Procedure LP for RCP Trip/Start, page 5 ERG Generic Issues for RCP Tripping pages 6 & 8 Cog Level Low Bank
Question Number:
97 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only S
K/A 000011K309 QUESTION Given the following:
Unit 1 has experienced a Large Break LOCA.
1BEP-1, LOSS OF REACTOR OR SECONDARY COOLANT is in progress.
The Unit Supervisor is directing step 10 of 1BEP-1, CHECK IF DGs SHOULD BE STOPPED.
The purpose of this step is to...
a.
minimize the time DGs are running unloaded so they are available later if needed.
b.
secure any running DGs to maintain an adequate day tank fuel oil supply.
c.
allow reset of the ESF Bus UV sequencer so one CV pump can be shutdown.
d.
ensure the SI signal was reset earlier so the NON-ESF to ESF crosstie breakers can be closed.
ANSWER A
REFERENCE WOG Background Document for E-1, step 10 on page 69.
B/B UFSAR pages 8.3-17 & 18 Cog Level Low New
Question Number:
98 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only S
K/A 000015A211 QUESTION A LOCA has occurred on Unit 1. Currently the steps of 1BFR-C.1 "Response To Inadequate Core Cooling" are being performed, and preparations are being made to start the 1C RCP.
The following plant conditions currently exist:
CETCs - 1205 deg F SGs depressurized to 85 psig RCS pressure - 1400 psig and increasing 1C SG level - 50% Narrow Range What are the MINIMUM conditions that must be met prior to starting the 1C RCP?
a.
Seal differential pressure must be GREATER THAN 200 psig, and the interlock associated with the lift oil pump must be met.
b.
Seal injection flow must be GREATER THAN 6 gpm and the interlock associated with the lift oil pump must be met.
c.
Only the interlock associated with the lift oil pump must be met.
d.
Bearing temperatures must be LESS THAN 195 deg F and seal differential pressure must be GREATER THAN 200 psig.
ANSWER C
REFERENCE Byron Simulator Procedure LP for BFR C.1 for note prior to step 17.
WOG Background Document for FR C.1: note prior to step 18 Cog Level High Bank
Question Number:
99 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only S
K/A 000057K301 QUESTION Given the following plant conditions:
A reactor trip and SI has occurred on Unit 2 from 100% power.
Just prior to the trip, Instrument Bus 214 became deenergized.
The Unit Supervisor is directing steps 5 thru 8 below of 2BEP-0, REACTOR TRIP OR SAFETY INJECTION.
Based on current plant status, all of the following steps will require use of the Response Not Obtained (RNO) column of the procedure EXCEPT:
a.
Step 5, VERIFY FW ISOLATION b.
Step 6, VERIFY ECCS PUMPS RUNNING c.
Step 7, VERIFY RCFCs RUNNING IN ACCIDENT MODE d.
Step 8, VERIFY CNMT ISOLATION PHASE A ANSWER A
REFERENCE 2BOA ELEC-2 TABLE D (page 1 of 3)
ILT Systems LP Ch 60a, page 48 ILT Systems LP Ch 25, pages 69-70 Cog Level High New
Question Number:
100 Exam Date:
2003/12/11 Reactor Type:
PWR-WEC4 Both/SRO Only S
K/A 0000582128 QUESTION Which of the following describes the power supply arrangement to DC Bus 113, and the Tech Spec Bases for this configuration?
a.
DC Bus 113 has its own supply breaker from Battery 111; this provides better load sharing during a loss of offsite power event.
b.
DC Bus 111 supplies DC Bus 113 thru a fuse; this ensures a fault on the non-Class 1E Bus 113 will NOT cause a loss of the Class 1E Bus 111.
c.
DC Bus 113 has its own supply breaker from Battery 111; this ensures a fault on the non-Class 1E Bus 113 will NOT cause a loss of the Class 1E Bus 111.
d.
DC Bus 111 supplies DC Bus 113 thru a fuse; this allows deenergization of Bus 113 for testing while maintaining DC Bus 111 energized.
ANSWER B
REFERENCE LCO 3.8.4 Bases, pages B 3.8.4-1 ILT Systems LP Ch 8a, page 6 Cog Level Low New