ML031260606
ML031260606 | |
Person / Time | |
---|---|
Site: | Cook |
Issue date: | 04/30/2003 |
From: | Jack Giessner Indiana Michigan Power Co |
To: | Document Control Desk, Office of Nuclear Reactor Regulation |
References | |
AEP:NRC:3691-03 | |
Download: ML031260606 (153) | |
Text
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
MR U2037-02 23 Cs-137 2.10E+OO l.90E+00 6.30E+O0 MR L3037-02 23 Fe-59 6.60E+00 6.40E+00 2.20E+01 MR L3037-02 23 1-131 -6.00E-02 1.70E-01 8.10E-OI MR L3037-02 23 K-40 1.72E+03 7.40E+01 9.30E+OI MR L3037-02 23 La-140 -7.OOE-01 3.90E+00 I.SOE+0I MR L3037-02 23 Mn-54 -1.50E+00 1.70E+00 6.30E+O0 MR L3037-02 23 Nb-95 -6.00E-01 2.OOE+00 7.40E+00 MR L3037-02 23 Ru-103 -8.OOE-OI 1.90E+00 6.70E+00 MR L3037-02 23 Ru-106 -I.OOE+OI 1.70E+01 6.20E+0I MR L3037-02 23 Sb-124 5.70E+00 3.90E+00 1.30E+OI MR L3037-02 23 Sb-125 2.40E+00 4.00E+00 1.40E+OI MR 13037-02 23 Se-75 -I.IOE+O0 2.10E+00 7.30E+O0 MR 13037-02 23 Zn-65 -5.80E+00 4.80E+00 1.80E+OI MR L3037-02 23 Zr-95 -4.30E+00 3.OOE+00 1.20E+0O SF L3037-03 23 AcTh-228 -5.50E+00 5.20E+00 I.90E+0O SF L3037-03 23 Ag-108m 6.OOE-01 I.OOE+O0 3.50E1+O0 SF L3037-03 23 Ag- lOim -I.OOE+O0 1.80E+00 6.60E+O0 SF L3037-03 23 Ba-140 2.40E+00 2.IOE+00 7.20E+00 SF L3037-03 23 Be-7 I.OOE+0O 1.20E+01 4.00E+0O SF L3037-03 23 Ce-141 3.70E+00 2.00Ei+00 6.40E+00 SF L3037-03 23 Ce-144 1.30E+00 7.IOE+00 2.40E+01 SF L3037-03 23 Co-57 8.90E-01 9.80E-01 3.30E+00 SF L3037-03 23 Co-58 -2.00E-01 1.30E+00 4.60E+00 SF L3037-03 23 Co-60 1.30E+00 1.60E+00 5.50E+00 SF L3037-03 23 Cr-51 -1.40E+01 1.40E+01 4.90E+01 SF L3037-03 23 Cs-134 -2.00E-01 1.30E+00 4.50E+00 SF L3037-03 23 Cs-137 2.OOE+00 1.40E+00 4.70E+00 SF L3037-03 23 Fe-59 4.60E+00 4.20E+00 1.40E+0I SF L3037-03 23 1-131 -6.00E-02 I.50E-0I 8.10E-0O SF L3037-03 23 K-40 1.33E+03 5.10E+01 6.50E+01 SF L3037-03 23 La-140 2.70E+00 2.40E+00 8.30E+00 SF L3037-03 23 Mn-54 O.OOE+00 1.40E+00 4.80E+00 SF L3037-03 23 Nb-95 -I.OOE-OI 1.70E+00 5.90E+00 SF L3037-03 23 Ru-103 -2.00E-01 1.50E+00 5.30E+00 SF U3037-03 23 Ru-106 -3.OOE+00 1.30E+01 4.60E+01 SF L3037-03 23 Sb-124 -1.40E+00 2.90E+00 I.IOE+0I SF L3037-03 23 Sb-125 -2.20E+00 3.30E+00 1.20E+0O SF L3037-03 23 Se-75 -2.00E-01 1.70E+00 5.90E+00 SF L3037-03 23 Zn-65 -5.OOE+00 3.30E+00 1.20E+0I SF L3037-03 23 Zr-95 -4.OOE-01 2.30E+00 8.20E+00
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-101
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
LF L3037-04 23 AcTh-228 -1.IO0+00 5.20E+00 1.80E+0O LF L3037-04 23 Ag-108m -I.OOE+00 1.E10+00 4.00E+00 LF L3037-04 23 Ag-I lOm -1.70E+00 2.10E+00 7.40E+00 LF L3037-04 23 Ba-140 -1.30E+00 1.80E+00 7.20E+00 LF L3037-04 23 Be-7 -8.00E+00 1.20E+01 4.20E+0I LF L3037-04 23 Ce-141 -7.30E+00 2.30E+00 8.302+00 LF L3037-04 23 Ce-144 -1.96E+01 7.202+00 2.60E+0I LF L3037-04 23 Co-57 -5.00E-01 9.60E-01 3.30E+00 LF L3037-04 23 Co-58 -I.OOE+00 1.50E+00 5.50E+00 LF L3037-04 23 Co-60 2.60E+00 1.50E+00 4.90E+00 LF L3037-04 23 Cr-51 -1.20E+01 1.30E+01 4.70E+01 LF. L3037-04 23 Cs-134 4.00E-01 1.60E+00 5.60E+00 LF L3037-04 23 Cs-137 -5.00E-01 1.50E+00 5.20E+00 LF L3037-04 23 Fe-59 5.30E+00 3.902+00 1.30E+0I LF L3037-04 23 1-131 4.00E-01 3.00E-01 9.80E-01 LF L3037-04 23 K-40 1.48E+03 5.30E+01 7.30E+01 LF L3037-04 23 La-140 -1.50E+00 2.10E+00 8.30E+00 LF L3037-04 23 Mn-54 1.20E+00 1.50E+00 5.00E+00 LF L3037-04 23 Nb-95 1.602+00 1.60E+00 5.50E+00 LF L3037-04 23 Ru-103 -1.30E+00 1.40E-+00 5.10E+00 LF L3037-04 23 Ru-106 -7.00E+00 1.30E+01 4.50E+01 LF L3037-04 23 Sb-124 6.00E-01 2.80E+00 I.OOE+01 LF L3037-04 23 Sb-125 -3.80E+00 3.30E+00 1.20E+01 LF L3037-04 23 Se-75 3.40E+00 1.70E+00 5.702+00 LF L3037-04 23 Zn-65 -2.40E+00 3.50E+00 1.30E+01 LF L3037-04 23 Zr-95 -5.00E-01 2.302+00 8.30E+00 WF L3037-05 23 Aclh-228 2.30E+00 5.70E+00 2.00E+01 WF, L3037-05 23 Ag-108m 1.25E+00 9.502-01 3.20E+00 WF L3037-05 23 Ag-I lOm -3.20E+00 1.80E+00 6.80E+00 WF L3037-05 23 Ba-140 I.IOE+00 2.10E+00 7.60E+00 WF L3037-05 23 Be-7 8.00E+00 1.10E+01 3.70E+01 WF L3037-05 23 Ce-141 -2.20E+00 2.1OE+00 7.40E+00 WF L3037-05 23 Ce-144 -8.40E+00 6.40E+00 2.30E+OI WF L3037-05 23 Co-57 -6.00E-02 9.80E-01 3.30E+00 WF L3037-05 23 Co-58 2.00E-01 1.30E+00 4.602+00 WF L3037-05 23 Co-60 1.40E+00 1.30E+00 4.50E+00 WF L3037-05 23 Cr-51 -6.00E+00 1.20E+01 4.20E+01 WF L3037-05 23 Cs-134 -1.302+00 1.30E+00 4.702+00 WF L3037-05 23 Cs-137 1.902+00 1.40E+00 4.70E+00 WF L3037-05 23 Fe-59 8.OOE-01 4.202+00 1.50E+01
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-102
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
WF L3037-05 23 1-131 5.40E-01 3.30E-01 L.OOE+00 WF L3037-05 23 K-40 1.52E+03 5.30E+01 6.90E+01 WF L3037-05 23 La-140 1.30E+00 2.50E+00 8.70E+O0 WF L3037-05 23 Mn-54 -I.OOE-0 1.20E+00 4.30E+0O WF L3037-05 23 Nb-95 1.70E+00 1.30E+00 4.40E+0O WF L3037-05 23 Ru-103 3.OOE-01 1.40E+00 4.80E+0O WF L3037-05 23 Ru-106 -5.OOE+00 1.30E+01 4.50E+0O WF L3037-05 23 Sb-124 -1.30E+00 3.20E+00 1.20E+0O WF L3037-05 23 Sb-125 1.IOE+00 3.10E+00 I.IOE+0O WF L3037-05 23 Se-75 7.00E-01 1.30E+00 4.50E+00 WF L3037-05 23 Zn-65 1.40E+00 3.20E+00 I.IOE+0O WF L3037-05 23 Zr-95 4.30E+00 2.40E+00 7.70E+00 GTF L3143-01 25 AcTh-228 8.20E+00 5.20E+00 1.70E+0O GTF L3143-01 25 Ag-108m -1.20E+00 1.1OE+00 3.90E+00 GTF L3143-01 25 Ag- lOim -4.OOE-01 2.20E+00 7.60E+00 GTF L3143-01 25 Ba-140 -2.10E+00 3.20E+00 1.20E+0O GTF L3143-01 25 Be-7 I.OOE+00 1.IOE+01 3.90E+01 GTF L3143-01 25 Ce-141 1.50E+00 2.OOE+00 6.60E+00 GTF L3143-01 25 Cc-144 5.20E+00 6.70E+00 2.20E+0O GTF L3143-01 25 Co-57 9.80E-01 8.10E-01 2.70E+00 GTF L3143-01 25 Co-58 -1.20E+00 1.40E+00 5.OOE+00 GTF U3143-01 25 Co-60 -7.OOE-01 1.70E+00 6.30E+00 GTF L3143-01 25 Cr-51 L.OOE+0 1.30E+01 4.40E+01 GTF L3143-01 25 Cs-134 -1.30E+00 1.50E+00 5.50E+00 GTF L3143-01 25 Cs-137 -1.IOE+00 1.40E+00 5.20E+00 GTF L3143-01 25 Fe-59 I.OOE+O0 3.90E+00 1.30E+01 GTF L3143-01 25 1-131 5.10E-01 2.70E-01 7.70E-0O GTF L3143-01 25 K-40 1.46E+03 5.70E+01 8.40E+0I GTF L3143-01 25 La-140 -2.40E+00 3.70E+00 1.40E+01 GTF L3143-01 25 Mn-54 -1.90E+00 1.40E+00 5.30E+00 GTF L3143-01 25 Nb-95 9.OOE-01 1.70E+00 5.90E+00 GTF L3143-01 25 Ru-103 -I.OOE+00 1.50E+00 5.40E+00 GTF L3143-01 25 Ru-106 3.OOE+00 1.20E+01 4.30E+0O GTF L3143-01 25 Sb-124 -8.OOE+00 3.50E+00 1.50E+0O GTF L3143-01 25 Sb-125 -6.90E+00 3.20E+00 1.20E+0O GTF L3143-01 25 Se-75 -6.OOE-01 1.60E+00 5.50E+00 GTF L3143-01 25 Zn-65 O.OOE+00 3.40E+00 1.20E+01 GTF L3143-01 25 Zr-95 -3.OOE+00 2.40E+00 9.10E+00
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-103
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
MR L3143-02 25 AcTh-228 -9.OOE-01 4.60E+00 1.60E+01 MR L3143-02 25 Ag-108m l.lOE-01 8.80E-01 3.00E+00 MR L3143-02 25 Ag-I lOm O.OOE+00 1.50E+00 5.30E+00 MR L3143-02 25 Ba-140 -1.30E+00 2.10E+00 7.80E+00 MR L3143-02 25 Be-7 -L.70E+01 l.OOE+01 3.70E+01 MR L3143-02 25 Cc-141 -2.00E+00 2.00E+00 6.90E+00 MR L3143-02 25 Ce-144 1.42E+01 6.20E+00 2.00E+01 MR L3143-02 25 Co-57 6.80E-01 7.90E-01 2.70E+00 MR L3143-02 25 Co-58 -9.00-01 1.30E+00 4.50E+00 MR L3143-02 25 Co-60 1.40E+00 1.20E+00 4.10E+00 MR L3143-02 25 Cr-51 1.60E+0O 1.20E+01 4.00E+01 MR L3143-02 25 Cs-134 -8.OOE-01 1.30E+00 4.70E+00 MR L3143-02 25 Cs-137 -1.60E+00 1.20E+00 4.40E+00 MR L3143-02 25 Fe-59 l.OOE-0O 3.00E+00 1.10+01 -
MR U 143-02 25 1-131 8.OOE-01 3.40E-01 8.40E-01 MR L3143-02 25 K-40 1.79E+03 4.80E+01 5.70E+01 MR L3143-02 25 La-140 -1.50E+00 2.40E+00 9.00E+00 MR L3143-02 25 Mn-54 1.OOE-01 1.20E+00 4.10E+00 MR L3143-02 25 Nb-95 -2.80E+00 1.40E+00 5.102+00 MR L3143-02 25 Ru-103 2.00E-01 1.30E+00 4.30E+00 MR L3143-02 25 Ru-106 -5.00E+00 1.10+01 3.70E+01 MR L3143-02 25 Sb-124 -2.80E+00 2.80E+00 1.00+01 MR L3143-02 25 Sb-125 1.50E+00 2.80E+00 9.50E+00 MR L3143-02 25 Se-75 -7.00E-01 1.50E+00 5.10E+00 MR L3143-02 25 Zn-65 -3.00E+00 3.20E+00 1.10+01 MR L3143-02 25 Zr-95 -8.00E-01 2.00E+00 7.20E+00 SF L3143-03 25 AcTh-228 8.OOE-01 4.80E+00 1.60E+01 SF L3143-03 25 Ag-108m 4.10E-01 8.50E-01 2.90E+00 SF L3143-03 25 Ag-i lOm -2.OOE-01 1.502+00 5.202+00 SF L3143-03 25 Ba-140 1.20E+00 1.80E+00 6.202+00 SF L3143-03 25 Be-7 -6.20E+00 8.40E+00 3.00E+01 SF L3143-03 25 Ce-141 O.OOE+00 1.60E+00 5.30E+00 SF W3143-03 25 Ce-144 3.10E+00 5.40E+00 1.80E+01 SF L3143-03 25 Co-57 8.00E-02 7.00E-01 2.402+00 SF L3143-03 25 Co-58 1.44E+00 9.90E-01 3.30E+00 SF L3143-03 25 Co-60 7.00E-01 1.10E+00 3.70E+00 SF L3143-03 25 Cr-51 -1.70E+01 1.00+01 3.70E+01 SF L3143-03 25 Cs-134 -2.00E-01 .1OE+00 3.90E+00 SF L3143-03 25 Cs-137 8.00E-01 l.OOE+00 3.50E+00 SF L3143-03 25 Fe-59 2.00E+00 3.20E+00 1.l10E+01
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-104
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
SF L3143-03 25 1-131 4.50E-01 3.1OE-OI 9.80E-0O SF L3143-03 25 K-40 1.34E+03 4.20E+0O 6.OOE+0I SF L3143-03 25 La-140 1.30E+0O 2.OOE+00 7.10E+00 SF L3143-03 25 Mn-54 -6.60E-0O 9.60E-01 3.50E+00 SF L3143-03 25 Nb-95 -1.50E+00 1.60E+O0 5.90E+00 SF L3143-03 25 Ru-103 -2.30E+00 1.lOE+O0 4.20E+00 SF L3143-03 25 Ru-106 2.40E+00 9.30E+OO 3.20E+01 SF L3143-03 25 Sb-124 -3.40E+O0 2.30E+OO 9.OOE+00 SF L3143-03 25 Sb-125 2.OOE-01 2.50E+00 8.60E+0O SF L3143-03 25 Se-75 -3.OOE-01 l. lOE+O0 3.90E+0O SF L3143-03 25 Zn-65 -5.60E+00 2.60E+00 9.70E+00 SF L3143-03 25 Zr-95 -1.80E+00 1.80E+00 6.60E+00 LF L3143-04 25 AcTh-228 1.14E+01 5,30E+O0 1.70E+0O LF L3143-04 25 Ag-108m -2.00E-0O 1.1OE+00 3.70E+00 LF L3143-04 25 Ag- lOrm 5.OOE-0O 1.70E+00 6.10E+00 LF L3143-04 25 Ba-140 5.60E+00 3.70E+00 1.20E+0O LF L3143-04 25 Be-7 -I.OOE+00 1.lOE+01 3.80E+01 LF L3143-04 25 Ce-141 -1.50E+00 2.OOE+00 6.90E+00 LF L3143-04 25 Cc-144 -1.39E+01 6.50E+00 2.30E+0O LF L3143-04 25 Co-57 -1.56E+00 8.30E-01 2.90E+00 LF L3143-04 25 Co-58 1.40E+00 1.50E+O0 5.OOE+00 LF L3143-04 25 Co-60 8.00E-O1 1.70E+00 5.90E+00 LF L3143-04 25 Cr-51 5.OOE+00 1.40E+01 4.60E+0O LF L3143-04 25 Cs-134 -2.50E+00 1.501E+00 5.50E+00 LF L3143-04 25 Cs-137 1.70E+00 1.40E+O0 4.60E+00 LF L3143-04 25 Fe-59 5.90E+00 5.60E+00 1.90E+01 LF L3143-04 25 1-131 5.50E-01 3.30E-01 9.80E-01 LF L3143-04 25 K-40 1.38E+03 5.50E+0O 7.80E+01 LF L3143-04 25 La-140 6.40E+OO 4.20E+00 1.40E+0O LF L3143-04 25 Mn-54 2.30E+0O 1.60E+00 5.20E+00 LF L3143-04 25 Nb-95 -I.OOE-01 1.80E+OO 6.30E+00 LF L3143-04 25 Ru-103 -1.70E+00 1.50E+00 5.50E+00 LF L3143-04 25 Ru-106 1.60E+0O 1.30E+0O 4.20E+O1 LF L3143-04 25 Sb-124 2.20E+00 3.60E+00 1.30E+0O LF L3143-04 25 Sb-125 5.80E+00 3.40E+O0 I. IOE+01 LF L3143-04 25 Se-75 -2.OOE-0O 1.70E+00 5.70E+00 LF L3143-04 25 Zn-65 1.60E+00 3.50E+00 1.20E+0O LF L3143-04 25 Zr-95 -5.00E-0O 2.60E+00 9.30E+OO WF L3143-05 25 AcTh-228 2.50E+00 4.50E+00 1.5OE+OI WF L3143-05 25 Ag-108m 4.60E-OI 8.40E-O1 2.80E+OO
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-105
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
WF L3143-05 25 Ag-l1lm 2.00E-01 1.50E+00 5.00E+00 WF W3143-05 25 Ba-140 2.70E+00 2.202+00 7.30E+00 WF L3143-05 25 Be-7 5.OOE-01 8.70E+00 3.00E+01 WF L3143-05 25 Cc-141 -2.30E+00 1.702+00 5.80E+00 WF L3143-05 25 Ce-144 5.60E+00 5.402+00 1.802+01 WF L3143-05 25 Co-57 -1.20E+00 1.101O+00 3.90E+00 WF W143-05 25 Co-58 -2.00E-01 1.OOE+00 3.60E+00 WF 1W143-05 25 Co-60 0.OOE+00 1.20E+00 4.IOE+00 WF W3143-05 25 Cr-51 6.00E+00 1.10E+01 3.80E+01 WF W3143-05 25 Cs-134 1.70E+00 1.10E+00 3.60E+00 WF W3143-05 25 Cs-137 -5.00E-01 1.1OE+00 3.90E+00 -
WF W3143-05 25 Fe-59 1.60E+00 3.60E+00 1.202+01 WF W3143-05 25 1-131 -2.40E-01 1.30E-01 1.002+00 WF W3143-05 25 K-40 1.42E+03 4.00E+01 4.902+01 WF U 143-05 25 La-140 3.10E+00 2.50E+00 8.40E+00 WF L3143-05 25 Mn-54 -1.IOE+00 1.102+00 3.802+00 WF L3143-05 25 Nb-95 -1.I10E+00 1.50E+00 5.30E+00 WF L3143-05 25 Ru-103 -4.10E+00 1.10+00 4.30E+00 WF L3143-05 25 Ru-106 -1.56E+01 9.80E+00 3.50E+0O WE W3143-05 25 Sb-124 1.70E+00 2.20E+00 7.70E+00 WF L3143-05 25 Sb-125 -6.50E+00 2.50E+00 9.20E+00 WF W3143-05 25 Se-75 -5.00E-01 1.302+00 4.40E+00 WF 12143-05 25 Zn-65 -2.40E+00 2.30E+00 8.40E+00 WF W3143-05 25 Zr-95 8.00E-0O 1.80E+00 6.20E+00 GTF W3252-01 27 AcTh-228 -1.06E+0O 6.70E+00 2.50E+0I GTF W3252-01 27 Ag-108m I.OE+00 1.302+00 4.40E+00 GTF L3252-01 27 Ag- lOim -1.80E+00 2.50E+00 9.30E+00 GTF L3252-01 27 Ba-140 3.30E+00 2.90E+00 9.90E+00 GTF L3252-01 27 Be-7 -6.OOE+00 1.40E+01 5.00E+01 GTF L3252-01 27 Ce- 141 2.80E+00 2.40E+00 7.90E+00 GTF L3252-01 27 Cc-144 -1.70E+00 7.70E+00 2.60E+01 GTF L3252-01 27 Co-57 2.50E-01 9.60E-01 3.30E+00 GTF W3252-01 27 Co-58 -I.OOE+00 1.60E+00 5.90E+00 GTF W3252-01 27 Co-60 2.60E+00 1.902+00 6.30E+00 GTF W3252-01 27 Cr-51 -7.00E+00 1.502+01 5.20E+01 GTF L3252-01 27 Cs-134 1.30E+00 2.00E+00 6.90E+00 GTF L3252-01 27 Cs-137 -4.002-01 1.702+00 6.102+00 GTF L3252-01 27 Fe-59 -7.50E+00 6.20E+00 2.40E+01
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-106
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
GTF U3252-01 27 1-131 3.00E-01 1.90E-01 5.80E-01 GTF U3252-01 27 K-40 1.35E+03 6.40E+01 8.10E+01 GTF U3252-01 27 La-140 3.80E+00 3.30E+00 1.10+01 GTF U3252-01 27 Mn-54 -1.60E+00 1.60E+00 6.10E+00 GTF U3252-01 27 Nb-95 -2.30E+00 2.00E+00 7.50E+00 GTF U3252-01 27 Ru-103 -3.50E+00 1.80E+00 6.802+00 GTF U3252-01 27 Ru-106 -5.OOE+00 1.50E+01 5.20E+01 GTF U3252-01 27 Sb-124 O.OOE+00 3.90E+00 1.50E+01 GTF L3252-01 27 Sb-125 2.30E+00 4.10E+00 1.402+01 GTF L3252-01 27 Se-75 -2.80E+00 1.80E+00 6.60E+00 GTF U3252-01 27 Zn-65 -8.30E+00 4.40E+00 1.70E+01 GTF L3252-01 27 Zr-95 4.60E+00 2.90E+00 9.60E+00 MR L3252-02 27 AcTh-228 3.40E+00 7.60E+00 2.70E+01 MR L3252-02 27 Ag-108m 5.00E-01 1.30E+00 4.60E+00 MR L3252-02 27 Ag-l lOm 6.101E+00 2.70E+00 8.70E+00 MR L3252-02 27 Ba-140 3.90E+00 2.90E+00 9.60E+00 MR L3252-02 27 Be-7 3.50E+01 1.60E+01 5.00E+01 MR U2252-02 27 Ce-141 2.30E+00 2.40E+00 7.902+00 MR 12252-02 27 Ce-144 -7.20E+00 8.40E+00 2.90E+01 MR U3252-02 27 Co-57 3.00E-01 1.00E+00 3.50E+00 MR 12252-02 27 Co-58 -1.90E+00 1.60E+00 6.30E+00 MR U3252-02 27 Co-60 1.30E+00 2.20E+00 7.50E+00 MR L3252-02 27 Cr-51 2.20E+01 1.50E+01 5.00E+01 MR U3252-02 27 Cs-134 -1 .OOE-01 1.90E+00 6.90E+00 MR U3252-02 27 Cs-137 2.70E+00 1.70E+00 5.602+00 MR U3252-02 27 Fe-59 0.0023+00 6.40E+00 2.30E+01 MR U3252-02 27 1-131 2.20E-01 2.30E-01 8.60E-01 MR 12252-02 27 K-40 1.85E+03 7.60E+01 1.OOE+02 MR U3252-02 27 La-140 4.50E+00 3.30E+00 1.10E+O1 MR U3252-02 27 Mn-54 -3.60E+00 1.70E+00 6.80E+00 MR U3252-02 27 Nb-95 -9.OOE-01 2.00E+00 7.40E+00 MR U3252-02 27 Ru-103 -4.00E+00 1.80E+00 6.90E+00 MR U3252-02 27 Ru-106 1.30E+01 1.60E+01 5.30E+01 MR U3252-02 27 Sb-124 2.30E+00 5.00E+00 1.80E+01 MR 12252-02 27 Sb-125 2.70E+00 3.80E+00 1.30E+01 MR U3252-02 27 Se-75 -1.80E+00 1.90E+00 6.80E+00 MR U3252-02 27 Zn-65 5.00E-01 4.80E+00 1.70E+01 MR U2252-02 27 Zr-95 4.OOE-01 3.00E+00 I. IOE+01 SF U3252-03 27 AcTh-228 -1.00E-01 4.00E+00 1.40E+01 SF U3252-03 27 Ag-108m 3.10E-01 8.30E-01 2.80E+00
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-107
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCilkg)
SF L3252-03 27 Ag-l Orm 1.70E+00 1.40E+00 4.70E+O0 SF L3252-03 27 Ba-140 -6.20E+00 2.20E+00 8.90E+00 SF L3252-03 27 Be-7 6.10E+00 9.10E+00 3.10E+0I SF L3252-03 27 Ce-141 1.70E+00 1.70E+00 5.70E+00 SF L3252-03 27 Cc-144 -4.50E+00 5.80E+00 2.OOE+01 SF L3252-03 27 Co-57 7.10E-01 7.50E-01 2.50E+00 SF L3252-03 27 Co-58 1.90E+O0O I .IOE+00 3.50E+00 SF L3252-03 27 Co-60 1.70E+00 1.IOE+00 3.50E+00 SF L3252-03 27 Cr-51 -l.OOE+00 1.IOE+0I 3.70E+01 SF L3252-03 27 Cs-134 1.40E+00 1.20E+00 3.90E+00 SF L3252-03 27 Cs-137 7.OOE-O1 I.IOE+00 3.60E+00 SF L3252-03 27 Fe-59 3.30E+00 3.30E+00 I.1OE+0O SF L3252-03 27 1-131 3.70E-01 2.00E-01 5.70E-OI SF L3252-03 27 K-40 1.36E+03 3.80E+01 4.50E+0I SP L3252-03 27 La-140 -7.1OE+00 2.60E+00 I.OOE+01 SF L3252-03 27 Mn-54 3.00E-0O 1.OOE+00 3.60E+00 SF L3252-03 27 Nb-95 -3.OOE-01 1.50E+00 5.10E+00 SF L3252-03 27 Ru-103 -3.30E+00 1.I1E+00 4.20E+00 SF L3252-03 27 Ru-106 -3.30E+00 9.30E+00 3.20E+0I SF L3252-03 27 Sb-124 2.20E+00 2.40E+00 8.10E+00 SF L3252-03 27 Sb-125 8.00E-01 2.70E+00 9.10E+00 SF L3252-03 27 Se-75 -1.OOE-0I 1.30E+00 4.40E+00 SF 12252-03 27 Zn-65 9.OOE-01 3.70E+00 1.20E+01 SF L3252-03 27 Zr-95 4.OOE-01 1.80E+00 6.40E+00 LF 12252-04 27 AcTh-228 9.00E+00 3.70E+00 1.20E+01 LF L3252-04 27 Ag-108m -5.40E-01 7.60E-01 2.70E+00 LF L3252-04 27 Ag-l tOm -I.OOE-01 1.20E+00 4.20E+00 LF L3252-04 27 Ba-140 -2.OOE+00 1.80E+00 6.80E+00 LF W3252-04 27 Be-7 -5.70E+00 7.90E+00 2.80E+01 LF L3252-04 27 Ce-141 4.OOE-01 1.80E+00 6.OOE+00 LF L3252-04 27 Ce-144 9.40E+00 4.90E+00 1.60E+01 LF L3252-04 27 Co-57 -4.50E-01 7.80E-01 2.70E+00 LF L3252-04 27 Co-58 -1.25E+00 9.90E-01 3.60E+00 LF L3252-04 27 Co-60 -3.00E-01 l.IOE+O0 3.90E+00 LF L3252-04 27 Cr-51 5.90E+00 9.70E+00 3.30E+01 LF L3252-04 27 Cs-134 -1.57E+00 8.90E-01 3.30E+00 LF 12252-04 27 Cs-137 1.60E+00 1.OOE+00 3.30E+00 LF 12252-04 27 Fe-59 5.80E+00 3.20E3+00 1.OOE+01 LF 12252-04 27 1-131 2.80E-01 2.40E-01 8.50E-0O LF 12252-04 27 K-40 1.35E+03 3.80E+01 5.70E+0I
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-108
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
LF L3252-04 27 La-140 -2.30E+00 2.00E+O00 7.80E+00 LF 12252-04 27 Mn-54 1.85E+00 8.70E3-01 2.80E+00 LF U2252-04 27 Nb-95 8.001E-01 1.201E+00 4.OOE+00 LF L3252-04 27 Ru-103 -1.70E+00 3.80E+00 LF U3252-04 27 Ru-106 2.501E+00 9.301E+00 3.20E+01 LF U2252-04 27 Sb-124 1.OOE2+00 2.20E+00 7.7013+00 LF U2252-04 27 Sb-125 L OOE-01 2.401E+00 8.10E+00 LF U3252-04 27 Sc-75 9.OOE-01 l.OOE+00 3.30E+00 LF U3252-04 27 Zn-65 2.40E+00 2.30E+00 7.701E+00 LF U3252-04 27 Zr-95 -8.001-01 1.801E+00 6.30E+00 WF W3252-05 27 Aclb-228 3.30E+00 4.80E+00 1.60E+01 WF 12252-05 27 Ag-108m 8.10E-01 9.301E-01 3.10OE+00 WF 12252-05 27 Ag- IlOn -4.OOE-01 1.40E+00 5. IOE+00 WF L3252-05 27 Ba-140 -2.50E+00 2.10OE+00 8.40E+00 WF 12252-05 27 Be-7 1.13E+01 9.60E+00 3.20E+01 WF 12252-05 27 Ce-141 -4.10OE+00 2.OOE+00 7.20E+00 WF 12252-05 27 Cc-144 -2.1IOE+00 6.OOE+00 2.IOE+01 WF 12252-05 27 Co-57 5.OOE-01 8.70E-01 2.90E+00 WF 12252-05 27 C6-58 -1.OOE+00 I1.20E+00 4.50E+00 WF L3252-05 27 Co-60 -5.00OE-01 I1.40E+00 5.OOE+00 WF L3252-05 27 Cr-Si I.OOE+01 I1.20E.+01 4.OOE+01 WF 12252-05 27 Cs-134 5.001E-01 I. lOE+00 3.80E3+00 WF 12252-05 27 Cs-137 0.OOE3+00 I1.301E+00 4.40E+00 WF 12252-05 27 Fe-59 1.501E+00 4.10E+00 1.40E+01 WF U3252-05 27 1-131 3.50E-01 2.60E-01 8.40E-01 WF 12252-05 27 K-40 1.47E+03 4.80E+01 6.60E+01 WF 13252-05 27 La-140 -2.90E+00 2.40E+00 9.70E+00 WF L3252-05 27 Mn-54 -1 .20E+00 l.OOE+00 3.80E+00 WF 12252-05 27 Nb-95 O.OOE+00 1.401E+00 4.80E4-00 WF L3252-05 27 Ru-103 1.50E+00 I1.301E+00 4.50E+00 WF 12252-05 27 Ru-106 -2.OOE+00 1. lOE+01 3.90E+01 WF L3252-05 27 Sb-124 -2.30E+00 2.70E+00 I. IOE+01 WF L3252-05 27 Sb-125 3.80E+00 2.80E+00 9.301E+00 WF L3252-05 27 Se-75 -l1.20E+00 I1.20E+00 4.40E+00 WF L3252-05 27 Zn-65 2.60E+00 3.70E+00 1.20E+01 WF L3252-05 27 Zr-95 -4. 1OE+00 2.20E+00 8.30E+00 GTF L3335-01 29 AcTl-228 3.80E+00 4.70E+00 1.60E+01 GTF L3335-01 29 Ag-108m L.OOE-01 9.80E-01 3.50E+00
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-109
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
GTF L3335-01 29 Ag-l l0m -1.40E+00 1.70E+O0 6.30E+00 GTF L3335-0O 29 Ba-140 1.OOE+00 1.30E+00 4.90E+00 GTF L3335-0O 29 Be-7 9.20E+00 9.40E+00 3.20E+01 GTF L3335-01 29 Ce-141 -8.OOE-01 2.00E+00 7.1 OE+00 GTF L3335-01 29 Ce-144 9.30E+00 7.90E+00 2.60E+01 GTF L3335-01 29 Co-57 8.10E-0O 9.30E-01 3. 1OE+00 GTF L3335-01 29 Co-58 6.00E-01 1.IOE+00 3.80E+00 GTF L3335-01 29 Co-60 3.60E-01 9.20E-01 3.40E+O0 GTF L3335-01 29 Cr-51 -6.00E+00 I.1OE+01 4.1OE+OI GTF L3335-01 29 Cs-134 9.00E-0O 1.20E+00 4.10E+00 GTF L3335-01 29 Cs-137 -9.00E-01 1.20E+00 4.70E+O0 GTF L3335-01 29 Fe-59 4.70E+00 3. 10E+00 1.OOE+0l GTF L3335-01 29 1-131 3.10E-0O 2.70E-01 9.50E-01 GTF L3335-01 29 K-40 1.38E+03 5.30E+01 5.30E+01 GTF L3335-01 29 La-140 1.IOE+OO 1.50E+00 5.60E+00 GTF L3335-01 29 Mn-54 4.OOE-01 1.20E+00 4.10E+00 GTF L3335-01 29 Nb-95 1.70E+00 1.20E+00 4.00E+00 GTF L3335-01 29 Ru-103 6.OOE-01 l.IlOE+00 3.90E+O0 GTF L3335-01 29 Ru-106 1.30E+01 1.OOE+01 3.40E+01 GTF L3335-01 29 Sb-124 -1.50E+00 1.80E+00 8. 10E+00 GTF L3335-01 29 Sb-125 9.OOE-0O 2.90E+00 1.OOE+0I GTF L3335-01 29 Se-75 -1.OOE+00 1.50E+00 5.20E+00 GTF L3335-01 29 Zn-65 -4.40E+00 2.90E+O0 1.lOE+01 GTF L3335-01 29 Zr-95 2.00E-0O 2.00E+00 7.30E+00 MR L3335-02 29 AcTh-228 1.60E+00 4.70E+00 1.70E+0O MR L3335-02 29 Ag-108m 1.70E+O0 1.OOE+OO 3.40E+00 MR 1335-02 29 Ag-l lOm 4.00E-01 1.80E+00 6.20E3+00 MR L3335-02 29 Ba-140 3.OOE-01 1.60E+00 5.90E+00 MR 1335-02 29 Be-7 9.00E+O0 1.OOE+01 3.50E+01 MR L3335-02 29 Ce-141 8.OOE-01 2.20E+00 7.50E+00 MR L3335-02 29 Ce-144 5.60E+00 8. 1OE+O0 2.70E+01 MR L3335-02 29 Co-57 1.OOE+00 I. 1OE+00 3.60E+00 MR L3335-02 29 Co-58 -2.60E+00 1.20E+00 4.90E+00 MR L3335-02 29 Co-60 1.20E+O0 1.30E+00 4.50E+00 MR L3335-02 29 Cr-51 4.OOE+00 1.20E+01 4. IOE+01 MR L3335-02 29 Cs-134 -2. 10E+00 1.40E+00 5.30E+00 MR L3335-02 29 Cs-137 -1.90E+00 1.40E+00 5.20E+00 MR L3335-02 29 Fe-59 -1.20E+00 3.70E+00 1.40E1+0I MR L3335-02 29 1-131 4.OOE-01 3.00E-01 9.70E-01 MR L3335-02 29 K-40 1.83E+03 6.OOE+01 5.20E+0OI
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-110
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
MR L3335-02 29 La-140 4.OOE-01 1.80E+00 6.80E+00 MR L3335-02 29 Mn-54 7.OOE-0I 1.IOE+00 3.80E+00 MR L3335-02 29 Nb-95 2.OOE-0I 1.30E+00 4.60E+00 MR L3335-02 29 Ru-103 2.OOE-01 1.30E+00 4.60E+00 MR L3335-02 29 Ru-106 l.OOE+00 1.OOE+01 3.70E+0I MR L3335-02 29 Sb-124 -6.OOE-0I 2.50E+00 9.80E+00 MR L3335-02 29 Sb-125 -4.90E+00 2.80E+00 I.1OE+01 MR L3335-02 29 Se-75 8.OOE-0I 1.60E+00 5.50E+00 MR L3335-02 29 Zn-65 -2.80E+00 3.60E+00 1.30E+0I MR L3335-02 29 Zr-95 2.20E+00 1.90E+00 6.50E+O0 SF L3335-03 29 AcTh-228 4.OOE+00 4.50E+00 1.50E+0I SF L3335-03 29 Ag-108m -5.40E-0I 8.50E-01 3.1OE+00 SF L3335-03 29 Ag-I lOm -4.OOE-01 1.40E+00 5.30E+00 SF L3335-03 29 Ba-140 -1 .OOE+00 1.50E+00 6.OOE+00 SF L3335-03 29 Be-7 -7.50E+00 8.60E+00 3.20E+01 SF L3335-03 29 Ce-141 6.00E-0O 1.90E+00 6.70E+00 SF L3335-03 29 Ce-144 1.92E+0I 6.90E+00 2.20E+01 SF L3335-03 29 Co-57 1.08E+00 9.30E-01 3.10E+O0 SF L3335-03 29 Co-58 8.OOE-0I l.OOE+O0 3.60E+00 SF L3335-03 29 Co-60 O.OOE+00 1.20E+00 4.30E+00 SF L3335-03 29 Cr-51 -1.30E+0I 1.1OE+01 3.90E+01 SF L3335-03 29 Cs-134 l.OOE+00 l.lOE+00 3.80E+00 SF L3335-03 29 Cs-137 -1.20E+00 1.20E+00 4.60E+00 SF L3335-03 29 Fe-59 1.20E+00 3.80E+00 1.30E+01 SF L3335-03 29 1-131 4.OOE-02 2.OOE-01 9.70E-0O SF L3335-03 29 K-40 1.49E+03 5.30E+01 5.1OE+01 SF L3335-03 29 La-140 -1.20E+00 1.70E+00 6.80E+00 SF L3335-03 29 Mn-54 l.OOE-01 l.OOE+00 3.70E+00 SF L3335-03 29 Nb-95 -1 .30E+00 1.20E+00 4.70E+00 SF L3335-03 29 Ru-103 4.OOE-OI l.lOE+00 3.80E+00 SF L3335-03 29 Ru-106 3.60E+00 9.20E+00 3.30E+01 SF L3335-03 29 Sb-124 5.OOE-01 1.90E+00 7.50E+00 SF L3335-03 29 Sb-125 -5.OOE-0O 2.70E+00 9.80E+00 SF L3335-03 29 Se-75 O.OOE+00 1.20E+00 4.30E+00 SF L3335-03 29 Zn-65 4.40E+00 2.80E+00 I.IOE+01 SF L3335-03 29 Zr-95 1.90E+00 1.70E+00 5.90E+00 LF L3335-04 29 AcTh-228 -8.OOE+00 6.30E+00 2.40E+01 LF L3335-04 29 Ag-108m -3.OOE-01 l.lOE+00 3.90E+00 LF L3335-04 29 Ag-lOrm -IOOE-01 2.10E+00 7.80E+O0 LF L3335-04 29 Ba-140 3.10E+00 1.80E+00 5.90E+00
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-111
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
LF L3335-04 29 Be-7 -I.OOE+01 1.00+01 4.00E+01 LF L3335-04 29 Cc-141 1.50IE+00 2.90E+00 1.OOE+01 LF L3335-04 29 Ce-144 1.OOE+01 1.10E+01 3.80E+01 LF L3335-04 29 Co-57 1.70E+00 1.40E+00 4.50E+00 LF L3335-04 29 Co-58 6.OOE-01 1.402+00 5.10E+00 LF L3335-04 29 Co-60 2.1OE+00 1.70E+00 5.80E+00 LF L3335-04 29 Cr-51 -7.00E+00 1.302+01 4.70E+01 LF L3335-04 29 Cs-134 8.00E-01 1.60E+00 5.80E+00 LF L3335-04 29 Cs-137 4.00E-01 1.40E+00 5.20E+00 LF L3335-04 29 Fe-59 -1.11+01 4.60E+00 2.00E+01 LF L3335-04 29 1-131 9.00E-01 3.90E-01 9.30E-01 LF L3335-04 29 K-40 1.40E+03 6.30E+01 6.30E+01 LF L3335-04 29 La-140 3.50E+00 2.10E+00 6.80E+00 LF L3335-04 29 Mn-54 2.50E+00 1.50E+00 4.90E+00 LF L3335-04 29 Nb-95 -1.20E+00 1.80E+00 6.80E+00 LF L3335-04 29 Ru-103 -1.80E+00 1.60E+00 5.90E+00 LF L3335-04 29 Ru-106 O.OOE+00 1.202+01 4.40E+01 LF L3335-04 29 Sb-124 l.OOE+00 2.80E+00 1.1OE+01 LF L3335-04 29 Sb-125 3.50E+00 3.90E+00 1.30E+01 LF L3335-04 29 Se-75 8.00E-01 1.902+00 6.60E+00 LF L3335-04 29 Zn-65 3.10E+00 3.40E+00 1.202+01 LF L3335-04 29 Zr-95 4.1OE+00 2.602+00 8.40E+00 WF L3335-05 29 AcTh-228 -7.00E-01 6.90E+00 2.50E+01 WF L3335-05 29 Ag-108m -6.OOE-01 1.30E+00 4.70E+00 WF L3335-05 29 Ag-I lOIm 2.90E+00 2.10E+00 7.102+00 WF L3335-05 29 Ba-140 -1.902+00 2.802+00 1.202+01 WF L3335-05 29 Be-7 2.20E+01 1.30E+01 4.20E+01 WF L3335-05 29 Cc- 141 1.60E+00 2.602+00 8.70E+00 WF L3335-05 29 Ce-144 8.60E+00 9.30E+00 3.IOE+01 WF L3335-05 29 Co-57 -2.30E+00 1.20E+00 4.302+00 WF L3335-05 29 Co-58 -1.50E+00 1.40E+00 5.70E+00 WF L3335-05 29 Co-60 -6.00E-01 2.00E+00 7.60E+00 WF L3335-05 29 Cr-51 -9.00E+00 1.60E+01 5.70E+01 WF L3335-05 29 Cs-134 -3.00E+00 1.602+00 6.90E+00 WF L3335-05 29 Cs-137 1.00-01 1.802+00 6.40E+00 WF L3335-05 29 Fe-59 2.50E+00 5.10E+00 1.902+01 WF L3335-05 29 1-131 5.40E-01 3.10E-01 8.902-01 WF L3335-05 29 K-40 1.37E+03 7.40E+01 8.002+01 WF L3335-05 29 La-140 -2.20E+00 3.20E+00 1.302+01 WF L3335-05 29 Mn-54 3.80E+00 1.60E+00 4.70E+00
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-1 12
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
WF L3335-05 29 Nb-95 -2.OOE+00 1.80E+00 7.30E+00 WF L3335-05 29 Ru-103 -2.10E+00 1.60E+00 6.30E+00 WF L3335-05 29 Ru-106 2.20E+01 1.50E+01 5.OOE+01 WF L3335-05 29 Sb-124 -3.OOE+00 3.60E+00 1.60E+01 WF L3335-05 29 Sb-125 -1 ,OOE+O0 3.80E+00 1.40E+01 WF L3335-05 29 Se-75 1.70E+OO l.90E+00 6.40E+00 WF L3335-05 29 Zn-65 4.40E+00 3.50E+00 1.20E+01 WF L3335-05 29 Zr-95 2.20E+00 2.90E+00 l.OOE+01 GTF L3449-01 31 AcTh-228 9.OOE-0O 5.40E+00 l.90E+01 GTF L3449-01 31 Ag-108m 8.20E-01 8.90E-01 3.OOE+00 GTF L3449-01 31 Ag- lOnm 2.OOE-01 1.50E+00 5.30E+00 GTF L3449-01 31 Ba-140 -6.OOE-0O 1.90E+00 7.OOE+00 GTF L3449-01 31 Be-7 -9.60E+00 9.20E+00 3.30E+01 GTF L3449-01 31 Ce-141 -8.OOE-01 2.OOE+00 6.70E+00 GTF L3449-01 31 Ce-144 -2.60E+00 6.10E+00 2.1OE+01 GTF L3449-01 31 Co-57 -2.OOE-02 9.OOE-01 3. 1OE+00 GTF L3449-01 31 Co-58 I.OOE+00 1.IOE+00 3.80E+00 GTF L3449-01 31 Co-60 5.00E-01 1.30E+00 4.50E+00 GTF L3449-01 31 Cr-51 -5.OOE+00 1.1OE+01 3.90E+01 GTF L3449-01 31 Cs-134 1.30E+00 1.20E+00 3.90E+00 GTF L3449-01 31 Cs-137 -9.OOE-01 1.20E+00 4.30E+00 GTF L3449-01 31 Fe-59 -7.OOE-01 2.90E+00 1.OOE+01 GTF L3449-01 31 1-131 3.OOE-02 1.60E-01 8.10E-01 GTF L3449-01 31 K-40 1.26E+03 4.50E+01 6.20E+01 GTF L3449-01 31 La-140 -7.OOE-01 2. 1OE+00 8.10E+00 GTF L3449-01 31 Mn-54 1.20E+00 1.IOE+00 3.70E+00 GTF L3449-01 31 Nb-95 -1.70E+00 1.30E+00 4.90E+00 GTF U3449-01 31 Ru-103 -2.OOE-0I 1.20E+00 4.10E+00 GTF L3449-01 31 Ru-106 -1.1OE+01 1.1OE+01 3.90E+01 GTF U3449-01 31 Sb-124 -1 .IOE+00 2.60E+00 9.80E+00 GTF L3449-01 31 Sb-125 4.OOE-01 2.80E+00 9.80E+00 GTF U3449-01 31 Se-75 1.90E+00 1.20E+00 3.90E+00 GTF U3449-01 31 Zn-65 -3.80E+00 2.90E+00 l.IOE+01 GTF U3449-01 31 Zr-95 1.30E+00 2. 1OE+00 7.20E+00 MR U3449-02 31 AcTh-228 1.30E+01 7.30E+00 2.40E+O1 MR U3449-02 31 Ag-108m -1.IOE+00 1.20E+00 4.40E+00 MR U3449-02 31 Ag-I lOim -5.OOE-01 2.40E+00 8.60E+00 MR U3449-02 31 Ba-140 3.40E+00 2.90E+00 9.90E+00
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-113
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
MR L3449-02 31 Be-7 0.OOE+00 1.40E+01 4.70E+I0 MR L3449-02 31 Ce-141 - 2.20E+00 2.70E+00 9.10E+00 MR L3449-02 31 Ce-144 -I.OOE-0O 9.70E+00 3.30E+01 MR L3449-02 31 Co-57 -I.OOE-0O 1.30E+00 4.30E+00 MR L3449-02 31 Co-58 -2.20E+00 I .70E+00 6.30E3+00 MR L3449-02 31 Co-60 -4.OOE-01 1.70E+00 6.30E+00 MR L3449-02 31 Cr-51 1.70E+01 1.60E+01 5.30E+0O MR L3449-02 31 Cs-134 -4.30E+00 1.70E+00 6.60E+00 MR L3449-02 31 Cs-137 1.40E1+00 1.60E+00 5.30E+O0 MR L3449-02 31 Fe-59 I.OOE+00 4.00E+00 1.40E+01 MR L3449-02 31 1-131 -4.OOE-02 1.30E-01 8.10E-OI MR L3449-02 31 K-40 1.66E+03 6.30E+01 8.50E+OI MR L3449-02 31 LA-140 3.90E+00 3.30E+00 1.IOE+01 MR L3449-02 31 Mn-54 1.50E+00 1.80E+00 6.20E+00 MR L3449-02 31 Nb-95 -3.50E+00 2.70E+00 I.OOE+OI MR L3449-02 31 Ru-103 -5.10E+00 1.70E+00 6.60E+00 MR L3449-02 31 Ru-106 -2.50E+01 1.50E+01 5.40E+01 MR L3449-02 31 Sb-124 2.50E+00 3.70E+00 1.30E+01 MR W3449-02 31 Sb-125 -1.OOE+00 3.80E+00 1.30E+01 MR 12449-02 31 Se-75 4.30E+00 2.OOE+00 6.60E+00 MR 12449-02 31 Zn-65 -1.53E+01 4.IOE+00 1.70E+01 MR 12449-02 31 Zr-95 -3.60E+00 3.1OE+00 l.lOE+01 SF 1W449-03 31 AcTh-228 -9.40E+00 6.70E+00 2.60E+0O SF L3449-03 31 Ag-108m -3.OOE-01 1.30E+00 4.70E+00 SF 12449-03 31 Ag-l lOm -1.30E+00 2.50E+00 9.20E+00 SF L3449-03 31 Ba-140 2.80E+00 2.80E+00 9.80E3+00 SF L3449-03 31 Be-7 2.OOE+01 1.40E-+01 4.60E+0I SF L3449-03 31 Ce-141 -4.80E+00 2.20E+00 8.1OE+00 SF L3449-03 31 Ce-144 1.18E+01 7.80E+00 2.60E+0O SF L3449-03 31 Co-57 -8.OOE-0 1.OOE+O0 3.50E+00 SF 12449-03 31 Co-58 -4.OOE-01 1.70E+00 6.10E+00 SF L3449-03 31 Co-60 -1.40E+00 2.00E+00 7.60E+00 SF 12449-03 31 Cr-51 -1.80E+01 1.50E+01 5.40E+0O SF 12449-03 31 Cs-134 1.40E+00 1.70E+00 5.90E+00 SF L3449-03 31 Cs-137 -3.90E+00 1.80E+00 7.1OE+00 SF L3449-03 31 Fe-59 -7.30E+00 4.60E+00 1.80E+Ot SF L3449-03 31 1-131 5.00E-01 2.90E-01 8.30E-01 SF 12449-03 31 K-40 1.48E+03 6.90E+01 9.30E+0I SF 12449-03 31 La-140 3.20E+00 3.20E+00 I.IOE+01 SF W3449-03 31 Mn-54 0.OOE+00 1.80E+00 6.50E+00
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-l 14
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
SF L3449-03 31 Nb-95 -2.20E+00 2.10E+00 7.70E+00 SF L3449-03 31 Ru-103 -3.20E+00 1.60E+00 6.20E+0O SF L3449-03 31 Ru-106 4.OOE+00 1.60E+01 5.40E+OI SF L3449-03 31 Sb-124 3.1OE+00 3.70E+00 1.30E+01 SF L3449-03 31 Sb-125 2.30E+00 4.10E+00 1.40E+01 SF L3449-03 31 Se-75 2.60E+O0 l.90E+00 6.1OE+00 SF L3449-03 31 Zn-5 -9.OOE-01 4.40E+00 1.60E+01 SF L3449-03 31 Zr-95 2.70E+00 2.90E+00 9.90E+00 LF L3449-04 31 AcTh-228 7.50E+00 7.OOE+00 2.30E+0O LF L3449-04 31 Ag-108m 2.OOE-01 1.40E+00 4.70E+OO LF L3449-04 31 Ag-Il0m 1.OOE+00 2.50E+00 8.60E+00 LF L3449-04 31 Ba-140 -5.OOE-01 3.OOE+00 I.IOE+01 LF L3449-04 31 Be-7 I.OOE+01 1.20E+01 4.20E+01 LF L3449-04 31 Ce-141 -6.OOE-01 2.30E+00 7.80E+OO LF L3449-04 31 Ce-144 -I.OOE+O0 7.70E+00 2.60E+0O LF L3449-04 31 Co-57 3.OOE-02 9.90E-01 3.40E+0O LF L3449-04 31 Co-58 7.OOE-01 1.50E+00 5.40E+O0 LF L3449-04 31 Co-60 -1.OOE-01 1.80E+00 6.80E+O0 LF L3449-04 31 Cr-51 -1.30E+01 I.50E+0 5.40E+01 LF L3449-04 31 Cs-134 -1.40E+00 2.OOE+00 7.40E+00 LF L3449-04 31 Cs-137 3.80E+00 1.80E+0O 5.70E+00 LF L3449-04 31 Fe-59 3.30E+00 4.20E+C0 1.50E+0O LF L3449-04 31 1-131 3.40E-01 2.60E-01 8.30E-01 LF L3449-04 31 K-40 1.46E+03 6.80E+01 9.80E+0I LF L3449-04 31 La-140 -6.OOE-01 3.40E+00 1.30E+0O LF L3449-04 31 Mn-54 2.30E+00 1.60E+00 5.50E+OO LF L3449-04 31 Nb-95 1.50E+00 2.OOE+00 6.70E+OO LF L3449-04 31 Ru-103 -1.70E+00 1.60E+00 5.90E+00 LF L3449-04 31 Ru-106 O.OOE+00 1.50E+01 5.20E+0I LF L3449-04 31 Sb-124 5.40E+00 4.1OE+00 1.40E+01 LF L3449-04 31 Sb- 125 4.30E+00 4.40E+00 1.50E+01 LF L3449-04 31 Sc-75 -3.40E+00 1.90E+00 7.OOE+00 LF L3449-04 31 Zn-65 3.70E+00 4.40E+00 1.50E+O1 LF L3449-04 31 Zr-95 -1.9OE+00 2.80E+O0 l.1OE+O1 WF L3449-05 31 Aclb-228 -1.30E+0O 5.20E+00 1.80E+01 WF L3449-05 31 Ag-108m -1.72E+00 9.90E-01 3.60E+00 WF L3449-05 31 Ag-I lOm -1.80E+00 1.70E+00 6.20E+00 WF L3449-05 31 Ba-140 -2.30E+00 2.30E+00 8.80E+0O WF L3449-05 31 Be-7 1.49E+01 9.20E+00 3.OOE+0O WF L3449-05 31 Ce-141 3.60E+00 1.80E+00 6.OOE+00
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-l 15
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
WF L3449-05 31 Ce-144 4.00E+00 6.70E+00 2.30E+01 -
WF L3449-05 31 Co-57 -2.17E+00 8.60E-01 3. 10E+00 WF L3449-05 31 Co-58 -1.70E+00 1.30E+00 4.70E+00 WF L3449-05 31 Co-60 1.70E+00 1.30E+00 4.30E+00 WF L3449-05 31 Cr-51 -1.OOE+01 1.1OE+0I 4.00E+01 WF L3449-05 31 Cs-134 -1.00E+00 1.30E+00 4.80E+00 WF L3449-05 31 Cs-137 -2.00E-0l 1.30E+00 4.50E+00 WF L3449-05 31 Fe-59 -2.40E+00 3.10+00 1.1OE+01 WF L3449-05 31 1-131 1.50E-01 2.00E-01 8.00E-01 WF L3449-05 31 K-40 1.44E+03 4.90E+01 6.00E+01 WF L3449-05 31 La-140 -2.70E+00 2.70E+00 1.00+01 WF L3449-05 31 Mn-54 4.00E-01 1.30E+00 4.40E+00 WF L3449-05 31 Nb-95 -3.40E+00 I .50E+00 5.80E+00 WF L3449-05 31 Ru-103 6.00E-01 1.40E+00O 4.70E+00 WF L3449-05 31 Ru-106 -6.OOE+00 1.20E+01 4.30E+01 WF L3449-05 31 Sb-124 -3.20E+00 2.902+00 1.10+01 WF L3449-05 31 Sb-125 -2.00E-01 3.20E+00 1.10+01 WF L3449-05 31 Se-75 1.1OE+00 1.50E+00 5.00E+00 WF L3449-05 31 Zn-65 -1.50E+00 2.80E+00 1.OOE+01 WF L3449-05 31 Zr-95 -2.00E-01 2.10E+00 7.50E+00 GTF L3560-01 33 AcTh-228 -7.50E+00 4.90E+00 1.90E+01 GTF L3560-01 33 Ag-108m I .40E+00 l.1OE+00 3.80E+00 GTF L3560-01 33 Ag-I lOm -4.00E-01 1.70E+00 6.10E+00 GTF L3560-01 33 Ba-140 -3.00E-01 1.50E+00 6.00E+00 GTF L3560-01 33 Be-7 6.30E+00 9.40E+00 3.30E+01 GTF L3560-01 33 Cc-141 -4.40E+00 2.30E+00 8.20E+00 GTF L3560-01 33 Ce- 144 -2.00E+00 8.50E+00 2.90E+01 GTF L3560-01 33 Co-57 1.lOE+00 1.00+00 3.50E+00 GTF L3560-01 33 Co-58 -9.OOE-01 1.40E+00 5. 102+00 GTF L3560-01 33 Co-60 -4.00E-01 1.20E+00 4.50E+00 GTF L3560-01 33 Cr-51 3.00E+00 1.20E+01 4.00E+01 GTF L3560-01 33 Cs-134 -1.60E+00 I .30E+00 5.20E+00 GTF L3560-01 33 Cs-137 1.20E+00 1.30E+00 4.40E+00 GTF L3560-01 33 Fe-59 -7.00E-01 3.40E+00 1.20E+01 GTF L3560-01 33 1-131 -1.40E-01 l.1OE-01 8.20E-01 GTF L3560-01 33 K-40 1.47E+03 5.60E+01 6.20E+01 GTF L3560-01 33 La- 140 -4.00E-01 1.80E+00 6.90E+00 GTF L3560-01 33 Mn-54 -I.OOE-01 1.20E+00 4.50E+00
- Radioactivity detected in sample (i.e., concentration > 3 X-standard deviation)
D-1 16
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
GTF L3560-01 33 Nb-95 -2.30E+00 1.301+00 5.10E+00 GTF L3560-01 33 Ru-103 -8.00E-01 1.30E+00 4.70E+00 GTF L3560-01 33 Ru-106 -1.OOE+00 l.1OE+01 4.10E+01 GTF L3560-01 33 Sb-124 2.00E+00 2.80E+00 1.002+01 GTF L3560-01 33 Sb-125 -4.00E+00 3.20E+00 1.20E+01 GTF L3560-01 33 Se-75 -1.40E+00 1.70E+00 6.102+00 GTF L3560-01 33 Zn-65 -7.90E+00 3.80E+00 1.50+01 GTF L3560-01 33 Zr-95 -3.00E+00 2.10E+00 8.30E+00 MR L3560-02 33 AcTh-228 1.45E+01 6.70E+00 2.10E+01 MR L3560-02 33 Ag-108m -1.IOE+00 1.30E+00 4.90E+00 MR L3560-02 33 Ag-l lOm 4.20E+00 2.50E+00 8.30E+00 MR L3560-02 33 Ba-140 -2.30E+00 1.90E+00 8.50E+00 MR L3560-02 33 Be-7 9.00E+00 1.40E+01 4.80E+01 MR L3560-02 33 Ce-141 3.60E+00 3.30E+00 1.10+01 MR L3560-02 33 Ce-144 -1.60E+01 1.20E+01 4.20E+0O MR L3560-02 33 Co-57 -1.20E+00 1.60E+00 5.40E+00 MR U3560-02 33 Co-58 1.90E+00 1.80E+00 6.00E+00 MR U 560-02 33 Co-60 1.lOE+00 1.40E+00 5.10E+00 MR L3560-02 33 Cr-51 2.40E+01 1.60E+01 5.30E+0O MR L3560-02 33 Cs-134 -2.40E+00 1.80E+00 7.00E+00 MR U3560-02 33 Cs-137 2.80E+00 1.50E+00 4.90E+00 MR L3560-02 33 Fe-59 -9.OOE-0O 4.00E+00 1.50E+01 MR L3560-02 33 1-131 7.OOE-0O 3.60E-01 9.30E-01 MR L3560-02 33 K-40 1.89E+03 7.50E+OI 6.60E+01 MR L3560-02 33 La-140 -2.70E+00 2.20E+00 9.80E+00 MR L3560-02 33 Mn-54 -6.OOE-0O 1.70E+00 6.10E+00 MR L3560-02 33 Nb-95 -4.OOE-01 1.80E+00 6.60E+00 MR L3560-02 33 Ru-103 2.OOE-01 1.80E+00 6.30E+00 MR L3560-02 33 Ru-106 8.00E+00 l .50E+0O 5.20E+01 MR L3560-02 33 Sb- 124 -3.OOE-01 2.30E+00 9.70E+00 MR L3560-02 33 Sb-125 l.OOE+00 4.30E+00 1.50+01 MR L3560-02 33 Se-75 -2.40E+00 2.20E+00 7.80E+00 MR L3560-02 33 Zn-65 -9.50E+00 4.30E+00 1.70E+01 MR L3560-02 33 Zr-95 4.30E+00 3.00E+00 9.90E+00 SF L3560-03 33 AcTh-228 4.50E+00 7.90E+00 2.80E+01 SF L3560-03 33 Ag-108m 3.OOE-0O 1.40E+00 5. 10E+00 SF L3560-03 33 Ag-I lOm 1.60E+00 2.80E+00 9.80E+00 SF L3560-03 33 Ba-140 -2.70E+00 3.00E+00 1.30E+01 SF L3560-03 33 Be-7 -2.00E+00 1.40E+01 5.00E+01 SF L3560-03 33 Ce-141 1.IOE+00 2.60E+00 9.00E+00
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-117
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
SF L3560-03 33 Ce-144 4.00E+00 1.00E+01 3.60E+0I SF L3560-03 33 Co-57 -1.40E+00 1.30E+00 4.70E+00 SF W3560-03 33 Co-58 0.00+00 1.80E+00 6.50E+00 SF - 3560-03 33 Co-60 4.90E+00 1.80E+00 5.OOE+00 SF L3560-03 33 Cr-51 -6.00E2+00 1.60E+01 5.60E+01 SF L3560-03 33 Cs-134 1.50E+00 1.602+00 5.70E+00 SF L3560-03 33 Cs-137 1.30E+00 1.80E+00 6.40E+00 SF L3560-03 33 Fe-59 2.70E+00 4.80E+00 1.70E+01 SF L3560-03 33 1-131 7.60E-01 3.50E-01 8.70E-01 SF L3560-03 33 K-40 1.33E+03 7.50E+01 7.70E+0I SF 12560-03 33 La-140 -3.10E+00 3.50E+00 1.50E+01 SF W3560-03 33 Mn-54 5.00E-01 1.80E+00 6.50E+00 SF L3560-03 33 Nb-95 -1.50E+00 2.002+00 7.80E+00 SF L3560-03 33 Ru-103 -2.30E+00 1.80E+00 7.00E+00 SF L3560-03 33 Ru-106 4.OOE+00 1.30E+01 4.70E+01 SF W3560-03 33 Sb-124 1.1OE+00 3.20E+00 1.30E+01 SF 12560-03 33 Sb-125 6.40E+00 4.60E+00 1.501E+01 SF L3560-03 33 Se-75 -2.20E+00 2.10E+00 7.70E+00 SF L3560-03 33 Zn-65 -2.70E+00 4.40E+00 1.70E+01 SF L3560-03 33 Zr-95 -2.70E+00 3.1OE+00 1.20E+01 LF L3560-04 33 Aclh-228 -6.90E+00 4.70E+00 1.802+01 LF L3560-04 33 Ag-108m -7.00E-0 I.lOE+00 4.002+00 LF L3560-04 33 Ag-llOm 2.20E+00 1.70E+00 5.60E+00 LF 12560-04 33 Ba-140 7.00E-01 1.80E+00 6.60E+00 LF L3560-04 33 Be-7 9.30E+00 9.30E+00 3.20E+01 LF L3560-04 33 Ce-141 -3.80E+00 2.20E+00 8.OOE+00 LF L3560 04 33 Ce-144 -1.23E+01 8.10E+00 2.90E+01 LF 12560-04 33 Co-57 -1.80E+00 I.IOE+00 3.80E+00 LF W3560-04 33 Co-58 0.OOE+00 1.30E+00 4.60E+00 LF L3560-04 33 Co-60 -9.00-01 1.402+00 5.30E+00 LF L3560-04 33 Cr-51 3.00E+00 1.20E+01 4.30E+01 LF L3560-04 33 Cs-134 I.OOE+00 1.20E+00 4.10E+00 LF L3560-04 33 Cs-137 -1.602+00 1.30E+00 4.902+00 LF L3560-04 33 Fe-59 7.50E+00 3.40E+00 I.IOE+01 LF L3560-04 33 1-131 -4.00E-02 1.30E-01 8.40E-01 LF L3560-04 33 K-40 1.43E+03 5.50E+01 6.00E+OI LF L3560-04 33 La-140 8.00E-01 2.10E+00 7.50E+00 LF L3560-04 33 Mn-54 I.OOE+00 I.IOE+00 3.80E+00 LF L3560-04 33 Nb-95 -1.40E+00 1.30E+00 5.IOE+00 LF L3560-04 33 Ru-103 -2.20E+00 1.20E+00 4.70E+00
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-1 18
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
LF L3560-04 33 Ru-106 -8.00E+00 I.IOE+01 4.00E+01 LF L3560-04 33 Sb-124 -2.OOE+00 2.10E+00 9.00E+00 LF L3560-04 33 Sb-125 -4.50E+00 3.20E+00 1.20E+01 LF L3560-04 33 Sc-75 3.00E-01 1.60E+00 5.70E+00 LF L3560-04 33 Zn-65 -2.00E+00 3.50E+00 1.30E+01 LF L3560-04 33 Zr-95 1.60E+00 2.00E+00 7.10E+00 WF L3560-05 33 AcTh-228 -2.60E+00 4.50E+00 1.70E+01 WF L3560-05 33 Ag-108m -4.OOE-01 1.lOE+00 3.90E+00 WF L3560-05 33 Ag- lOim O.OOE+00 1.50E+00 5.50E+00 WF L3560-05 33 Ba-140 - I.OOE+00 1.60E+00 6.70E+00 WF L3560-05 33 Be-7 -4.30E+00 9.80E+00 3.60E+01 WF L3560-05 33 Ce-141 -3.10E+00 2.20E+00 7.80E+00 WF L3560-05 33 Ce-144 -9.OOE+00 8.OOE+00 2.90E+O1 WF L3560-05 33 Co-57 -8.00E-01 1.OOE+00 3.70E+00 WF L3560-05 33 Co-58 9.OOE-01 1.20E+00 4. 10E+00 WF L3560-05 33 Co-60 -2.00E-01 1.30E+00 4.80E+00 WF L3560-05 33 Cr-51 -2.40E+01 1.20E+01 4.60E+01 WF L3560-05 33 Cs-134 1.20E+00 1.20E+00 4.1OE+00 WF L3560-05 33 Cs-137 1.70E+00 1.30E+00 4.30E+00 WF L3560-05 33 Fe-59 1.50E+00 2.60E+00 9.10E+00 WF L3560-05 33 1-131 2.20E-01 2.30E-01 8.60E-01 WF L3560-05 33 K40 1.29E+03 5.40E+01 6.00E+01 WF L3560-05 33 La-140 -1.20E+00 1.90E+00 7.70E+00 WF L3560-05 33 Mn-54 -6.OOE-01 1.20E+00 4.40E+00 WF L3560-05 33 Nb-95 1.50E+00 1.30E+00 4.40E+00 WF L3560-05 33 Ru-103 -7.OOE-01 1.20E+00 4.50E+00 WF L3560-05 33 Ru-106 I.OOE+00 1.10E+01 3.90E+01 WF L3560-05 33 Sb-124 2.70E+00 2.20E+00 7.60E+00 WF L3560-05 33 Sb-125 -6.OOE-01 3.00E+00 I.1OE+01 WF L3560-05 33 Se-75 2.OOE-01 1.70E+00 5.90E+00 WF L3560-05 33 Zn-65 -4.OOE-01 3.102E+00 1.10E+01 WF L3560-05 33 Zr-95 -2.OOE-0O 2.00E+00 7.50E+00 GTF L3685-01 35 AcTh-228 7.60E+00 4.10E+00 1.70E+01 GTF L3685-01 35 Ag-108m 6.60E-0O 8.20E-01 2.80E+00 GTF L3685-01 35 Ag- lOim -6.00E-01 1.60E+00 5.80E+00 GTF L3685-01 35 Ba-140 -1.20E+00 2.30E+00 8.30E+00 GTF L3685-01 35 Be-7 -7.30E+00 8.40E+00 3.00E+01 GTF L3685-01 35 Ce-141 4.00E-01 1.20E+00 4.00E+00
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-1 19
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
GTF L3685-01 35 Ce-144 -3.00E-01 5.00E+00 1.70E+0I GTF L3685-01 35 Co-57 6.60E-01 6.30E-01 2.IOE+00 GTF L3685-01 35 Co-58 3.00E-01 1.00+00 3.50E+00 GTF L3685-01 35 Co-60 1.40E+00 1.50E+00 5.OOE+00 GTF L3685-01 35 Cr-51 -4.60E+00 9.90E+00 3.40E+01 GTF L3685-01 35 Cs-134 -4.00E-O1 I.IOE+00 3.90E+00 GTF L3685-01 35 Cs-137 1.70E+00 1.IOE+00 3.60E+00 GTF L3685-01 35 Fe-59 -7.40E+00 4.00E+00 I.50E+O1 GTF L3685-01 35 1-131 4.60E-01 2.90E-01 9.00E-01 GTF L3685-01 35 K-40 1.44E+03 4.30E+01 5.80E+01 GTF L3685-01 35 La-140 -1.30E+00 2.60E+00 9.50E+00 GTF L3685-01 35 Mn-54 -2.60E+00 1.20E-+00 4.30E+00 GTF L3685-01 35 Nb-95 -2.80E+00 1.50E+00 5.50E+00 GTF L3685-01 35 Ru-103 -6.00E-01 1.IO0+00 3.80E+00 GTF 12685-01 35 Ru-106 -1.70E+01 1.00+01 3.60E+0l GTF L3685-01 35 Sb-124 -1.90E+00 2.402+00 9.20E+00 GTF L3685-01 35 Sb-125 3.OOE-01 2.40E+00 8.302+00 GTF L3685-01 35 Se-75 O.OOE+00 1.20E+00 4.20E+00 GTF L3685-01 35 Zn-65 -4.00E-01 2.70E+00 9.50E+00 GTF L3685-01 35 Zr-95 O.OOE+00 1.80E+00 6.40E+00 MR L3685-02 35 AcTh-228 4.60E+00 6.OOE+00 2.00E+01 MR L3685-02 35 Ag-108m -1.30E-01 9.80E-01 3.40E+00 MR L3685-02 35 Ag-lOrm 1.20E+00 1.90E+00 6.60E+00 MR L3685-02 35 Ba-140 -2.20E+00 3.00E+00 I.IOE+0I MR L3685-02 35 Be-7 7.00E+00 1.10+01 3.70E+0I MR L3685-02 35 Ce-141 -4.60E+00 1.80E+00 6.40E+00 MR L3685-02 35 Ce-144 4.OOE-01 6.20E+00 2.l10E+I01 MR L3685-02 35 Co-57 6.OOE-02 7.80E-01 2.70E+00 MR L3685-02 35 Co-58 -7.00E-01 1.40E+00 5.00E+00 MR L3685-02 35 Co-60 7.00E-01 1.90E+00 6.60E+00 MR L3685-02 35 Cr-51 1.40E+01 1.30E+01 4.202+01 MR L3685-02 35 Cs-134 1.80E+00 1.40E+00 4.80E+00 MR L3685-02 35 Cs-137 -I.OOE-01 1.50E+00 5.10E+00 MR L3685-02 35 Fe-59 7.10+00 4.80E+00 1.60E+01 MR L3685-02 35 1-131 5.00E-02 I.90E-01 9.30E-0I MR L3685-02 35 K-40 1.72E+03 5.60E+01 7.OOE+01 MR L3685-02 35 La-140 -2.60E+00 3.40E+00 1.30E+01 MR L3685-02 35 Mn-54 3.00E-01 1.40E+00 4.80E+00 MR L3685-02 35 Nb-95 -5.20E+00 1.802+00 6.80E+00 MR L3685-02 35 Ru-103 8.00E-01 1.40E+00 4.60E+00
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-120
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
MR L3685-02 35 Ru-106 -8.00E+00 1.30E+01 4.40E+01 MR L3685-02 35 Sb-124 -3.80E+00 4.10E+00 I.SOE+01 MR L3685-02 35 Sb-125 -3.30E+00 2.90E+00 I.1OE+01 MR L3685-02 35 Se-75 5.OOE-01 1.50E+00 5.10E+00 MR L3685-02 35 Zn-65 -1.IOE+00 3.50E+00 1.30E+01 MR L3685-02 35 Zr-95 2.80E+00 2.40E+00 8.OOE+00 SF L3685-03 35 AcTh-228 -4.20E+00 4.80E+00 1.80E+01 SF L3685-03 35 Ag-108m 8.OOE-0 L.OOE+00 3.40E+00 SF L3685-03 35 Ag-I lOm -3.OOE-01 I.90E+00 6.70E+00 SF L3685-03 35 Ba-140 -1.60E+00 2.40E+00 9.20E+00 SF L3685-03 35 Be-7 -2.OOE+O0 I.IOE+0I 3.90E+0O SF L3685-03 35 Ce-141 I.OOE+00 2.20E+00 7.50E+00 SF L3685-03 35 Ce-144 3.20E+00 6.70E+00 2.30E+0O SF L3685-03 35 Co-57 -1.41E+00 9.OOE-01 3.20E+00 SF L3685-03 35 Co-58 1.OOE-0 1.30E+00 4.40E+00 SF L3685-03 35 Co-60 9.OOE-01 1.50E+00 5.10E+00 SF L3685-03 35 Cr-51 -1.20E+01 1.30E+01 4.70E+0O SF L3685-03 35 Cs-134 -I.OOE-0 1.20E+00 4.40E+OO SF L3685-03 35 Cs-137 4.OOE-01 1.40E+00 4.70E+00 SF L3685-03 35 Fe-59 4.50E+00 3.70E+00 1.20E+01 SF L3685-03 35 1-131 8.OOE-02 2.10E-01 9.1OE-0O SF L3685-03 35 K-40 1.19E+03 4.50E+01 6.30E+01 SF L3685-03 35 La-140 -1.80E+00 2.80E+00 I.IOE+01 SF L3685-03 35 Mn-54 -1.60E+00 1.30E+00 4.90E+00 SF L3685-03 35 Nb-95 5.OOE-01 1.60E+00 5.60E+00 SF L3685-03 35 Ru-103 3.OOE-01 1.30E+00 4.60E+00 SF L3685-03 35 Ru-106 -5.OOE+00 1.20E+01 4.30E+01 SF L3685-03 35 Sb-124 -1.40E+00 3.50E+00 1.30E+0O SF L3685-03 35 Sb-125 -4.OOE-01 3.OOE+00 I.OOE+0I SF L3685-03 35 Se-75 1.80E+00 1.60E+00 5.20E+00 SF L3685-03 35 Zn-65 -3.80E+00 3.30E+00 1.20E+0O SF L3685-03 35 Zr-95 3.30E+00 2.20E+00 7.20E+00 LF L3685-04 35 AcTh-228 7.50E+00 5.60E+00 1.90E+01 LF W3685-04 35 Ag-108m O.OOE+00 9.60E-01 3.30E+00 LF L3685-04 35 Ag-l lOm -5.90E+00 2.OOE+00 7.60E+00 LF L3685-04 35 Ba-140 -4.00E-01 3.10E+00 I.IOE+OI LF L3685-04 35 Be-7 -3.OOE+00 L.OOE+01 3.60E+OI LF L3685-04 35 Ce-141 1.20E+00 1.80E+00 6.20E+00 LF L3685-04 35 Ce-144 3. 1OE+00 6.40E+00 2.10E+01 LF L3685-04 35 Co-57 -5.OOE-01 8.20E-01 2.80E+00
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-121
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
LF L3685-04 35 Co-58 L.OOE-OI 1.30E+00 4.70E+00 LF L3685-04 35 Co-60 7.OOE-01 1.70E+00 5.80E+O0 LF L3685-04 35 Cr-51 -1.30E+01 1.20E+01 4.40E+01 LF L3685-04 35 Cs-134 -8.00E-01 1.40E+00 5.10E+00 LF L3685-04 35 Cs-137 -1.20E+00 1.40E+00 5.00E+O0 LF L3685-04 35 Fe-59 -1.27E+01 5.20E+00 2.OOE+01 LF L3685-04 35 1-131 2.40E-01 2.60E-01 9.60E-0I LF L3685-04 35 K-40 1.32E+03 5.00E3+01 7.30E+01 LF L3685-04 35 La-140 -4.OOE-01 3.50E+00 1.30E+01 LF L3685-04 35 Mn-54 -1.OOE+00 1.30E+00 4.SOE+00 LF L3685-04 35 Nb-95 -4.OOE-01 1.60E+00 5.70E+00 LF W3685-04 35 Ru-103 8.00E-01 1.30E+00 4.40E+00 LF L3685-04 35 Ru-106 -1.60E+01 1.20E+01 4.40E+01 LF L3685-04 35 Sb-124 -1.40E+00 3.20E+00 1.20E+01 LF L3685-04 35 Sb-125 -3.90E+00 3.20E+00 1.IOE+01 LF L3685-04 35 Se-75 1.80E+00 1.50E+00 5.00E+00 LF L3685-04 35 Zn-65 -8.00E-01 3.30E+00 1.20E+01 LF L3685-04 35 Zr-95 -3.50E+00 2.50E+00 9.40E+00 WF L3685-05 35 AcTh-228 -6.102+00 5.60E+00 2.OOE+0I WF L3685-05 35 Ag-108m l.OOE-01 I.IOE+00 3.80E+OO WF L3685-05 35 Ag-llOm -9.OOE-0 I.90E+00 6.80E+00 WF L3685-05 35 Ba-140 -7.00E-01 2.80E+00 I.OOE+01 WF U3685 35 Be-7 1.60E+01 1.20E+01 3.90E+01 WF L3685-05 35 Ce-141 1.90E+00 2.20E+00 7.30E+00 WF L3685-05 35 Ce-144 -3.80E+00 7.20E+00 2.50E+01 WF L3685-05 35 Co-57 1.31E+00 9.1OE-01 3.00E+00 WF L3685-05 35 Co-58 2.00E-01 1.40E+00 5.00+E+0 WF L3685-05 35 Co-60 1.OOE-01 1.70E+00 6.00E+00 WF L3685-05 35 Cr-51 -1.40E+01 1.40E+01 5.10E+01 WF L3685-05 35 Cs-134 2.002-01 1.302+00 4.70E+00 WF L3685-05 35 Cs-137 -4.00E-01 1.402+00 5.102+00 WF W3685-05 35 Fe-59 3.40E+00 4.70E+00 1.60E+01 WF L3685-05 35 1-131 7.50E-01 3.60E-01 9.90E-01 WF L3685-05 35 K-40 1.33E+03 5.1OE+0I 7.00+E+1 WF L3685-05 35 La-140 -9.OOE-01 3.20E+00 1.20E+01 WF L3685-05 35 Mn-54 -2.10E+00 1.40E+00 5.10E+00 WF L3685-05 35 Nb-95 -1.80E+00 1.70E+00 6.30E+00 WF L3685-05 35 Ru-103 -3.40E+00 1.50E+00 5.80E+00 WF L3685-05 35 Ru-106 3.00E+00 1.30E+01 4.40E+01 WF L3685-05 35 Sb-124 O.OOE+00 3.40E+00, 1.20E+01
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-122
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
WF L3685-05 35 Sb-125 -2.20E+00 3.20E+00 1.20E+01 WF L3685-05 35 Se-75 1.OOE-0 1.70E+00 5.90E+00 WF L3685-05 35 Zn-65 2.40E+00 3.10E+0O 1.IOE+01 WF L3685-05 35 Zr-95 2.60E+00 2.40E+00 8.10E+00 GTF L3798-01 37 AcTh-228 -4.80E+00 5.60E+00 2.10E+0O GTF L3798-01 37 Ag-108m -6.OOE-01 1.1OE+00 3.90E+00 GTF L3798-01 37 Ag-I1lm 2.OOE+00 1.90E+00 6.50E+OO GTF L3798-01 37 Ba-140 4.OOE-01 2.10E+00 7.70E+OO GTF L3798-01 37 Be-7 -8.OOE+00 l.OOE+0 3.70E+0O GTF L3i98-01 37 Ce-141 -I.IOE+00 2.10E+00 7.40E+00 GTF L3798-01 37 Ce-144 -8.40E+00 7.60E+00 2.70E+01 GTF L3798-01 37 Co-57 -I.IOE-OI 9.50E-01 3.30E+00 GTF L3798-01 37 Co-58 -7.OOE-01 1.40E+00 5.10E+00 GTF L3798-01 37 Co-60 -1.80E+00 1.80E+00 6.80E+00 GTF L3798-01 37 Cr-51 1.80E+01 1.20E+01 4.OOE+01 GTF L3798-01 37 Cs-134 I.OOE+O0 1.40E+00 5.OOE+0O GTF L3798-01 37 Cs-137 -1.20E+00 1.40E+00 5.20E+00 GTF L3798-01 37 Fe-59 1.20E+00 3.10E+0O 1.IOE+01 GTF L3798-01 37 1-131 O.OOE+00 1.80E-01 9.10E-01 GTF L3798-01 37 K-40 1.41E+03 5.90E+01 6.60E+0I GTF L3798-01 37 La-140 5.OOE-01 2.40E+00 8.90E+00 GTF L3798-01 37 Mn-54 2.OOE-01 1.30E+00 4.70E+00 GTF L3798-01 37 Nb-95 -2.90E+00 1.50E+00 6.OOE+00 GTF L3798-01 37 Ru-103 O.OOE+00 1.30E+00 4.70E+00 GTF L3798-0l 37 Ru-106 6.OOE+00 I.IOE+01 3.90E+0O GTF L3798-01 37 Sb-124 -2.50E+00 2.90E+00 1.20E+01 GTF L3798-01 37 Sb-125 2.40E+00 3.40E+00 1.20E+01 GTF L3798-01 37 Se-75 I.IOE+00 1.60E+00 5.50E+00 GTF L3798-01 37 Zn-65 -2.OOE+00 3.30E+00 1.20E+01 GTF L3798-01 37 Zr-95 1.20E+00 2.20E+00 7.70E+00 MR L3798-02 37 AcTh-228 3.50E+00 4.60E+00 1.60E+0O MR L3798-02 37 Ag-108m 6.40E-01 9.50E-01 3.30E+00 MR L3798-02 37 Ag-I lOm -7.OOE-01 1.40E+00 5.20E+00 MR L3798-02 37 Ba-140 -1.20E+00 1.70E+00 6.90E+OO MR L3798-02 37 Be-7 2.OOE+00 9.20E+00 3.30E+0O MR L3798-02 37 Ce-141 -2.30E+00 2.10E+00 7.40E+00 MR L3798-02 37 Ce-144 1.72E+01 7.70E+00 2.50E+01 MR L3798-02 37 Co-57 1.09E+00 9.50E-01 3.20E+OO
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-123
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
MR L3798-02 37 Co-58 -7.00E-01 I.IOE+00 4.20E+00 MR L3798-02 37 Co-60 I.IOE+00 1.40E+00 4.80E+O0 MR L3798-02 37 Cr-51 -6.OOE+00 1.20E+01 4.20E+01 MR L3798-02 37 Cs-134 1.20E+00 1.30E+00 4.40E+00 MR L3798-02 37 Cs-137 3.OOE-01 1.30E+00 4.70E+00 MR L3798-02 37 Fe-59 2.70E+00 3.20E+00 1.1OE+01 MR L3798-02 37 1-131 2.50E-01 2.60E-01 9.70E-01 MR L3798-02 37 K-40 1.90E+03 6.OOE+01 4.80E+01 MR L3798-02 37 La-140 -1.40E+00 1.90E+00 7.90E+00 MR L3798-02 37 Mn-54 -8.OOE-01 1.IOE+00 4.OOE+00 MR L3798-02 37 Nb-95 -6.OOE-01 1.20E+00 4.50E+00 MR L3798-02 37 Ru-103 -5.OOE-01 1.20E+00 4.50E+00 MR L3798-02 37 Ru-106 4.OOE+00 1.1OE+0 3.80E+01 MR L3798-02 37 Sb-124 I.OOE+00 2.20E+00 8.20E+00 MR L3798-02 37 Sb-125 -3.10E+00 2.60E+00 9.90E+00 MR L3798-02 37 Se-75 I.OOE-01 1.30E+00 4.70E+00 MR L3798-02 37 Zn-65 6.OOE-01 3.OOE+00 I.IOE+0O MR L3798-02 37 Zr-95 1.80E+00 2.20E+00 7.70E+00 SF L3798-03 37 AcTh-228 2.50E+00 5.OOE+00 1.70E+01 SF L3798-03 37 Ag-108m -I.IOE+00 I.OOE+00 3.70E+00 SF L3798-03 37 Ag-ll0m 1.20E+00 1.70E+00 6.OOE+00 SF L3798-03 37 Ba-140 -5.OOE-01 2.OOE+00 7.70E+00 SF W3798-03 37 Be-7 1.40E+0I I.OOE+01 3.40E+01 SF L3798-03 37 Ce-141 -7.50E+00 2.50E+00 9.10E+O0 SF 12798-03 37 Ce-144 1.66E+01 8.70E+00 2.90E+0O SF 12798-03 37 Co-57 1.40E+00 1.IOE+00 3.70E+00 SF 12798-03 37 Co-58 -3.OOE-01 I.IOE+00 4.OOE+00 SF L3798-03 37 Co-60 -4.OOE-01 1.50E+00 5.30E+00 SF L3798-03 37 Cr-51 7.OOE+00 1.30E+01 4.30E+0I SF L3798-03 37 Cs-134 1.30E+00 1.30E+00 4.50E+00 SF W3798-03 37 Cs-137 1.40E+00 1.20E+00 3.90E+00 SF 12798-03 37 Fe-59 1.50E+00 2.90E+00 I.OOE+0O SF L3798-03 37 1-131 1.70E-01 2.30E-01 9.40E-0O SF L3798-03 37 K-40 1.24E+03 4.80E+01 5.40E+0I SF L3798-03 37 La-140 -6.OOE-01 2.30E+00 8.80E+00 SF L3798-03 37 Mn-54 -7.OOE-01 1.20E+00 4.50E+00 SF L3798-03 37 Nb-95 Q.OOE+0O 1.50E+00 5.20E+00 SF L3798-03 37 Ru-103 9.OOE-01 1.30E+00 4.60E+00 SF 12798-03 37 Ru-106 -6.80E+00 9.60E+00 3.50E+01 SF L3798-03 37 Sb-124 1.80E+00 2.70E+00 9.80E+00
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-124
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
SF L3798-03 37 Sb-125 -2.20E+00 2.90E+00 I .OOE+0O SF L3798-03 37 Se-75 -l.OOE-0O 1.60E+O0 5.60E+00 SF L3798-03 37 Zn-65 -6.40E+00 2.80E+00 l.lOE+0O SF L3798-03 37 Zr-95 -3.30E+00 2.30E+00 8.70E+00 LF L3798-04 37 AcTh-228 9.40E+00 4.90E+00 1.60E+0O LF L3798-04 37 Ag-108m 4.OOE-0O I.IOE+00 3.80E+O0 LF L3798-04 37 Ag-I lOm -3.70E+00 1.90E+00 7.50E+00 LF L3798-04 37 Ba-140 -1.20E+00 1.70E+00 7.10E+O0 LF L3798-04 37 Be-7 1.20E+O1 L.IOE+OI 3.70E+01 LF L3798-04 37 Ce-141 -3.90E+00 2.60E+00 9.30E+00 LF L3798-04 37 Ce-144 O.OOE+00 8.70E+00 3.OOE+01 LF L3798-04 37 Co-57 -1.20E+00 1.20E+00 4.10E+00 LF L3798-04 37 Co-58 -3.00E-01 1.30E+00 4.90E+00 LF L3798-04 37 Co-60 I.OOE+00 1.80E+00 6.IOE+00 LF L3798-04 37 Cr-51 3.50E+01 1.30E+01 4.20E+0I LF L3798-04 37 Cs-134 1.30E+00 1.20E+00 4.20E+00 LF L3798-04 37 Cs-137 1.50E+00 1.30E+00 4.50E+00 LF L3798-04 37 Fe-59 -4.20E+00 3.20E+00 1.20E+0O LF L3798-04 37 1-131 -1.90E-01 1.30E-01 9.90E-0O LF L3798-04 37 K-40 1.49E+03 5.70E+01 5.60E+0I LF L3798-04 37 La-140 -1.40E+00 I.90E+00 8.10E+00 LF L3798-04 37 Mn-54 -I.50E+00 1.20E+00 4.80E+00 LF L3798-04 37 Nb-95 2.OOE+00 2.70E+00 9.OOE+O0 LF L3798-04 37 Ru-103 -2.30E+O0 I.50E+00 5.80E+00 LF L3798-04 37 Ru-106 -2.IOE+01 1.20E+01 4.60E+OI LF L3798-04 37 Sb-124 -I.IOE+00 2.60E+00 I.IOE+OI LF L3798-04 37 Sb-125 -3.50E+00 3.30E+00 1.20E+01 LF L3798-04 37 Se-75 I.OOE+00 1.80E+00 6.30E+O0 LF L3798-04 37 Zn-65 7.50E+00 6.20E+00 2.1OE+O1 LF L3798-04 37 Zr-95 1.60E+00 2.30E+00 8.10E+O0 WF L3798-05 37 Aclb-228 6.60E+00 4.30E+00 1.40E+01 WF L3798-05 37 Ag-108m -1.OIE+O0 9.20E-01 3.40E+O0 WF L3798-05 37 Ag-I lOm -8.OOE-01 1.40E+00 5.40E+00 WF L3798-05 37 Ba-140 7.OOE-01 2.00E+00 7.40E+00 WF L3798-05 37 Be-7 O.OOE+OO I.OOE+0I 3.60E+OI WF L3798-OS 37 Ce-141 -2.50E+00 2.OOE+00 7.30E+OO WF L3798-05 37 Ce-144 5.20E+00 7.40E+00 2.50E+0O WF L3798-05 37 Co-57 3.50E-01 9.50E-01 3.30E+00 WF L3798-05 37 Co-58 -2.10E+00 1.20E+00 4.70E+00 WF L3798-05 37 Co-60 1.20E+00 1.70E+00 5.90E+00
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-125
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
WF L3798-05 37 Cr-51 -1.20E+01 1.IOE+0I 4.00E+01 WF L3798-05 37 Cs-134 1.80E+00 1.20E+00 4.10E+00 WF L3798-05 37 Cs-137 5.00E-01 1.30E+00 4.60E+00 WF L3798-05 37 Fe-59 -3.30E+00 2.80E+00 1.lOE+OI WF L3798-05 37 1-131 -4.OOE-02 1.50E-01 9.60E-01 WF L3798-05 37 K-40 1.42E+03 5.20E+01 5.002+01
- WF L3798-05 37 La- 140 8.OOE-01 2.30E+00 8.60E+00 WF L3798-05 37 Mn-54 0.OOE+O0 l.OOE+00 3.80E+00 WF L3798-05 37 Nb-95 1.80E+00 1.30E+00 4.30E+00 WF L3798-05 37 Ru-103 -1.50E+00 1.30E+00 4.70E+00 WF L3798-05 37 Ru-106 5.OOE+00 1.lOE+01 3.70E+01 WF L3798-05 37 Sb-124 l.OOE+00 2.60E+00 9.50E+00 WF L3798-05 37 Sb-125 1.40E+00 2.70E+00 9.50E+00 WF L3798-05 37 Se-75 -2.OOE+00 1.50E+00 5.40E+00 WF L3798-05 37 Zn-65 1.90E+00 3.00E+00 l.OoE+0o WF L3798-05 37 Zr-95 3.30E+00 1.70E+00 5.30E+00 GTF L3923-01 39 AcTh-228 4.70E+00 6.20E+00 2.20E+01 GTF L3923-01 39 Ag-108m -1.10E+00 1.30E+00 4.90E+00 GTF 12923-01 39 Ag-l lOm 2.30E+00 2.30E+00 7.80E+00 GTF L3923-01 39 Ba-140 -2.50E+00 2.90E+00 1.20E+01 GTF L3923-01 39 Be-7 9.OOE+00 1.40E+01 4.80E+01 GTF L3923-01 39 Ce-141 -1.90E+00 3.40E+00 1.20E+01 GTF L3923-01 39 Ce-144 1.30E+01 1.20E+01 4.00E+01 GTF L3923-01 39 Co-57 -3.20E+00 1.50E+00 5.50E+00 GTF L3923-01 39 Co-58 1.50E+00 1.70E+00 5.90E+00 GTF L3923-01 39 Co-60 7.00E-01 1.80E+00 6.50E+00 GTF L3923-01 39 Cr-51 -4.00E+00 1.70E+01 5.90E+0I GTF U3923-01 39 Cs-134 O.OOE+00 1.80E+00 6.60E+00 GTF L3923-01 39 Cs-137 -4.00E-01 1.50E+00 5.70E+00 GTF L3923-01 39 Fe-59 3.90E+00 5.20E+00 1.80E+01 GTF L3923-01 39 1-13 l.OE-01 2.80E-01 9.80E-01 GTF L3923-01 39 K-40 1.48E+03 6.80E+01 7.50E+01 GTF L3923-01 39 La-140 -2.90E+00 3.30E+00 1.40E+01 GTF L3923-01 39 Mn-54 2.20E+00 1.70E+00 5.60E+00 GTF L3923-01 39 Nb-95 9.00E-01 2.OOE+00 7.10E+00 GTF L3923-01 39 Ru-103 3.70E+00 l.90E+00 6.00E+00 GTF L3923-01 39 Ru-106 -1.40E+01 1.50E+01 5.60E+01 GTF L3923-01 39 Sb- 124 2.00E-01 3.20E+00 1.30E+01
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-126
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
GTF L3923-01 39 Sb-125 -4.OOE+00 3.60E+00 1.40E+0l GTF L3923-01 39 Se-75 -1.80E+00 2.20E+00 7.90E+O0 GTF L3923-01 39 Zn-65 3.10E+00 7.OOE+00 2.40E+Ol GTF L3923-01 39 Zr-95 1.90E+00 2.90E+00 l .OOE+0I MR L3923-02 39 AcTh-228 -1.50E+00 7.60E+O0 2.80E+Ol MR L3923-02 39 Ag-108m 3.20E+00 1.50E+00 4.60E+00 MR L3923-02 39 Ag-i lOmn -8.OOE-01 2.90E+O0 I. lOE+01 MR U923-02 39 Ba-140 -8.OOE-01 3.10E+O0 1.30E+01 MR L3923-02 39 Be-7 -1.70E+01 1.40E+OI 5.50E+01 MR L3923-02 39 Ce-141 3.60E+00 3.OOE+00 9.90E+00 MR L3923-02 39 Cc-144 1.90E+OI I.OOE+O1 3.30E+01 MR L3923-02 39 Co-57 1.40E+00 1.30E+00 4.30E+00 MR L3923-02 39 Co-58 -4.80E+00 1.80E+00 7.80E+00 MR L3923-02 39 Co-60 2.OOE+00 2.70E+00 9.30E+O0 MR L3923-02 39 Cr-51 -1.OOE+0O 1.60E+0O 6.OOE+01 MR L3923-02 39 Cs-134 -3.OOE-01 2.OOE+00 7.60E+00 MR . U923-02 39 Cs-137 -4.OOE-01 2.10E+00 7.50E+00 MR L3923-02 39 Fe-59 3.20E+00 6.40E+00 2.30E+01 MR U3923-02 39 1-131 3.40E-01 2.90E-OI l.OOE+00 MR L3923-02 39 K-40 1.72E+03 8.50E+O1 9.60E+01 MR L3923-02 39 La-140 -9.OOE-01 3.60E+00 1.50E+01 MR U3923-02 39 Mn-54 -1.80E+00 1.60E+OO 6.60E+O0 MR L3923-02 39 Nb-95 -1.80E+00 2.10E+O0 8.30E+O0 MR U3923-02 39 Ru-103 -2.40E+00 2.OOE+00 7.80E+O0 MR L3923-02 39 Ru-106 -1.80E+01 1.70E+0O 6.40E+01 MR L3923-02 39 Sb-124 -2.20E+00 4.60E+00 l.90E+01 MR L3923-02 39 Sb-125 6.10E+00 4.IOE+00 1.30E+01 MR L3923-02 39 Se-75 4.OOE-01 2.50E+00 8.60E+00 MR L3923-02 39 Zn-65 2.OOE+00 5.40E+00 l.90E+01 MR L3923-02 39 Zr-95 -I.OOE+00 3.90E+OO 1.40E+01 SF L3923-03 39 AcTh-228 8.OOE+00 5.30E+00 1.70E+0O SF L3923-03 39 Ag-108m -1.50E+00 I.IOE+00 4.20E+OO SF L3923-03 39 Ag-llOm -2.OOE+00 1.80E+00 7.OOE+OO SF L3923-03 39 Ba-140 5.OOE-01 2.50E+00 9.30E+O0 SF L3923-03 39 Be-7 -9.OOE+00 1.20E+01 4.50E+0I SF L3923-03 39 Ce-141 -2.OOE-01 2.50E+O0 8.60E+OO SF L3923-03 39 Ce-144 -6.70E+00 8.90E+O0 3.1OE+O1 SF L3923-03 39 Co-57 -4.OOE-0O I.IOE+O0 3.90E+00 SF L3923-03 39 Co-58 -7.OOE-01 1.20E+00 4.50E+OO SF L3923-03 39 Co-60 5.OOE-01 1.60E+00 5.90E+OO
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-127
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
SF L3923-03 39 Cr-51 5.00E+00 1.40E+01 4.80E+01 SF L3923-03 39 Cs- 134 -1.40E+00 1.30E+00 5.20E+00 SF L3923-03 39 Cs-137 -7.00E-01 1.30E+00 4.90E+00 SF L3923-03 39 Fe-59 2.20E+00 4.80E+00 1.70E+01 SF L3923-03 39 1-131 1.60E-01 2.80E-01 I.OOE+OO SF L3923-03 39 K-40 1.28E+03 5.80E+01 7.00E+01 SF L3923-03 39 La-140 6.OOE-01 2.80E+00 I.IOE+01 SF L3923-03 39 Mn-54 1.40E+00 1.20E+00 4.20E+00 SF L3923-03 39 Nb-95 -4.00E-01 1.50E+00 5.60E+00 SF L3923-03 39 Ru-103 -1.20E+00 1.40E+00 5.20E+00 SF L3923-03 39 Ru-106 -2.00+OO0 1.10E+01 4.00E+01 SF L3923-03 39 Sb-124 1.30E+00 2.30E+00 8.60E+O0 SF L3923-03 39 Sb-125 -3.OOE+00 3.OOE+00 I.IOE+01 SF L3923-03 39 Se-75 -4.00E-01 1.90E+00 6.50E+00 SF L3923-03 39 Zn-65 -2.10E+00 3.30E+00 1.30E+01 SF L3923-03 39 Zr-95 -1.90E+00 2.30E+00 9.00E+00 LF L3923-04 39 AcTh-228 2.50E+00 5.10E+00 1.80E+01 LF L3923-04 39 Ag-108m 5.OOE-O1 1.20E+00 4.20E+00 LF L3923-04 39 Ag-I lOm -2.OOE+00 1.60E+00 6.40E+00 LF L3923-04 39 Ba-140 9.OOE-01 1.90E+00 7.20E+00 LF L3923-04 39 Be-7 -1.OOE+00 1.IOE+0 3.90E+01 LF L3923-04 39 Ce-141 I.OOE-01 2.60E+00 9.00E+00 LF L3923-04 39 Ce-144 8.00E+00 9.40E+00 3.20E+0I LF L3923-04 39 Co-57 8.00E-01 1.20E+00 4.10E+00 LF L3923-04 39 Co-58 6.00E-01 1.40E+00 5.1OE+00 LF L3923-04 39 Co-60 1.30E+00 1.40E+00 5.OOE+00 LF L3923-04 39 Cr-51 -6.00E+00 1.50E+01 5.30E+01 LF L3923-04 39 Cs-134 -1.50E+00 1.20E+00 5.00E+00 LF L3923-04 39 Cs-137 -2.80E+00 1.40E+00 5.50E+00 LF L3923-04 39 Fe-59 I.OOE+00 4.50E+00 1.60E+01 LF L3923-04 39 1-131 3.50E-01 2.90E-01 9.80E-01 LF L3923-04 39 K-40 1.45E+03 6.00E+01 5.50E+01 LF L3923-04 39 La-140 I.OOE+00 2.20E+00 8.20E+00 LF L3923-04 39 Mn-54 8.00E-01 1.IOE+00 3.90E+00 LF L3923-04 39 Nb-95 -2.502+00 1.60E+00 6.202+00 LF L3923-04 39 Ru-103 -3.10E+00 1.60E+00 6.20E+00 LF L3923-04 39 Ru-106 2.00E+01 1.20E+01 4.00E+01 LF L3923-04 39 Sb-124 3.90E+00 3.OOE+00 I.OOE+01 LF L3923-04 39 Sb-125 -5.40E+00 3.40E+00 1.30E+01 LF L3923-04 39 Se-75 -3.00E-01 1.60E+00 5.70E+00
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-128
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
LF L3923-04 39 Zn-65 2.90E+00 3.90E+0O I1.30E+01 LF L3923-04 39 Zr-95 3.OOE-01 2.30E+00 8.20E+00 WF L3923-05 39 AcTh-228 -1.40E+00 6.10E+00 2.20E+01 WF L3923-05 39 Ag- 108m 7.OOE-01 1.20E+0O 4. IOE+00 WF L3923-05 39 Ag-I lOm 2.30E+00 2.10E+00 7.30E+00 WF U3923-05 39 Ba-140 -3.30E+00 2.80E+00 1.20E+01 WF L3923-05 39 Be-7 -I1.50E+01 1.40E+OI 5.OOE+01 WF L3923-05 39 Ce-141 -7.OOE-O01 3.30E+0O 1.IOE+01 WF L3923-05 39 Ce-144 3.OOE+00 1.20E+0I 4.10E+01 WF L3923-05 39 Co-57 6.OOE-01 1.50E+00 5.IOE+00 WF. L3923-05 39 Co-58 3.10OE+00 1.60E+00 5.30E+OO WF L3923-05 39 Co-60 -4.OOE-01 2.OOE+00 7.20E+O0 WF U3923-05 39 Cr-51 -6.OOE+00 1.70E+O1 6.OOE+01 WF L3923-05 39 Cs-134 -LI OOE-01 1.60E+00 5.70E+O0 WF L3923-05 39 Cs-137 I1.90E+00 l.50E+O0 5. 1OE-i00 WF L3923-05 39 Fe-59 4.60E+O0 5.70E+00 2.OOE+01 WF L3923-05 39 1-131 2.40E-01 2.80E-0O 9.80E-01 WF L3923-05 39 K-40 I1.49E+03 6.20E+0O 5.70E+01 WF L3923-05 39 La-140 -3.80E-.00 3.20E+00 I1.30E+01 WF L3923-05 39 Mn-54 3.OOE-01 1.50E+0O 5.40E+00 WF L3923-05 39 Nb-95 -1.40E+00 2.OOE+0O 7.20E+00 WF L3923-05 39 Ru-103 O.OOE+00 1.80E+0O 6.40E+00 WF L3923-05 39 Ru-106 3.OOE+00 1.30E+01 4.70E+01 WF L3923-05 39 Sb-124 -7.70E+00 3.10E+0O 1.40E-,01 WF L3923-05 39 Sb-125 -2.40E+00 3.90E+00 1.40E+01 WF L3923-05 39 Se-75 -2.30E-i00 2.20E+OO 7.90E+00 WF L3923-05 39 Zn-65 1.30E+00 6.80E+OO 2.30E+01 WF L3923-05 39 Zr-95 -1 .60E+00 2.60E+0O 9.80E+O0 GTF L4043-01 41 AcTh-228 7.80E+00 4.30E+0O I1.40E+01 GTF L4043-01 41 Ag-108m -4.OOE-01 1.1OE+O0 3.80E+00 GTF L4043-01 41 Ag-l lOm 2.OOE-01 I .60E+0O 5.80E+00 GTF L4043-01 41 Ba-140 -8.001E-01 1.50E+0O 5.80E+00 GTF L4043-01 41 Be-7 2.OOE+O0 I.OOE+0O 3.60E+01 GTF L4043-01 41 Ce-141 4.001E-01 2.OOE+0O 6.90E+00 GTF L4043-01 41 Ce-144 -5.OOE+00 I .30E+0O 4.30E+01 GTF L4043-01 41 Co-57 7.OOE-01 1.10E+0O 3.50E+00 GTF L4043-01 41 Co-58 -2.60E+00 I .lOE+0O 4.50E+00 GTF L4043-01 41 Co-60 .1.30E+00 I .50E+00 5.70E+00
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-129
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
GTF L4043-01 41 Cr-51 3.OOE+00 1.20E+01 4.OOE+0O GTF L4043-01 41 Cs-134 6.OOE-01 1.30E+00 4.40E+00 GTF L4043-01 41 Cs-137 -1.50E+00 1.20E+00 4.50E+00 GTF L4043-01 41 Fe-59 6.70E+00 2.70E+00 8.30E+O0 GTF L4043-01 41 1-131 -4.00E-02 2.40E-01 9.80E-01 GTF L4043-01 41 K-40 1.48E+03 5.10E+01 4.90E+01 GTF L4043-01 41 La-140 -9.OOE-01 1.70E+00 6.70E+00 GTF L4043-01 41 Mn-54 -2.00E-01 1.20E+00 4.50E+00 GTF L4043-01 41 Nb-95 I.OOE-0O 1.40E+00 4.80E+00 GTF L4043-01 41 Ru-103 7.OOE-01 1.20E+00 4.10E+00 GTF L4043-01 41 Ru-106 -2.OOE+00 I.IOE+01 3.80E+01 GTF L4043-01 41 Sb-124 -9.OOE-01 2.50E+00 9.60E+00 GTF L4043-01 41 Sb-125 O.OOE+00 3.1OE+00 1.10E+01 GTF L4043-01 41 Se-75 7.00E-01 1.60E+00 5.50E+00 GTF L4043-01 41 Zn-65 5.10E+00 5.90E+00 2.00E+01 GTF L4043-01 41 Zr-95 2.90E+00 2.10E+00 7.10E+00 MR L4043-02 41 AcTh-228 8.80E+00 5.90E+00 2.00E+01 MR L4043-02 41 Ag-108m -1.00E-0O l.1OE+00 3.90E+00 MR L4043-02 41 Ag-lOrm -5.OOE-01 2.30E+00 8.OOE+00 MR L4043-02 41 Ba-140 -3.002-01 2.20E+00 8.30E+00 MR L4043-02 41 Be-7 1.80E+01 1.I0E+01 3.80E+01 MR L4043-02 41 Ce-141 -1.IO0+00 2.80E+00 9.60E+00 MR L4043-02 41 Ce-144 1.102+01 l.lOE+0O 3.50E+OI MR L4043-02 41 Co-57 8.OOE-01 1.40E+00 4.70E+00 MR L4043-02 41 Co-58 -1.00-01 130E+00 4.80E+00 MR L4043-02 41 Co-60 O.OOE+00 1.80E+00 6.50E+00 MR L4043-02 41 Cr-51 -4.00E+00 1.40E+01 4.90E+01 MR L4043-02 41 Cs-134 O.OOE+00. 1.50E+00 5.50E+00 MR LA043-02 41 Cs-137 -1.50E+00 1.50E+00 5.50E+00 MR L4043-02 41 Fe-59 -4.40E+00 3.50E+00 1.30E+O1 MR
- L4043-02 41 1-131 2.70E-01 2.80E-01 9.90E-O1 MR L4043-02 41 K-40 1.87E+03 6.40E+01 6.70E+01 MR L4043-02 41 La-140 -3.OOE-01 2.50E+00 9.50E+00 MR L4043-02 41 Mn-54 -3.30E+00 1.50E+00 5.70E+00 MR L4043-02 41 Nb-95 2.002+00 1.60E+00 5.50E+00 MR L4043-02 41 Ru-103 -7.00E-01 1.50E+00 5.30E+00 MR L4043-02 41 Ru-106 5.00E+00 I.IOE+01 3.702+01 MR L4043-02 41 Sb-124 -2.40E+00 2.90E+00 1.20E+01 MR L4043-02 41 Sb-125 1.IOE+00 3.40E+00 1.20E+01 MR L4043-02 41 Se-75 1.30E+00 1.90E+00 6.402+00
- Radioactivity detected In sample (i.e., concentration > 3 X standard deviation)
D-130
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
MR L4043-02 41 Zn-65 -8.40E+00 3.80E+O0 1.50E+01 MR L4043-02 41 Zr-95 O.OOE+00 2.40E+00 8.60E+00 SF L4043-03 41 AcTh-228 -2.60E+00 6.OOE+00 2.20E+01 SF L4043-03 41 Ag-108m -5.OOE-01 1.20E+00 4.20E+O0 SF L4043-03 41 Ag-I lOm 5.OOE-01 2.20E+00 8.OOE+00 SF L4043-03 41 Ba-140 -5.OOE-01 2.OOE+00 8.10E+OO SF L4043-03 41 Be-7 3.OOE+00 l.OOE+0O 3.70E+O1 SF LA043-03 41 Ce-141 4.20E+00 2.20E+00 7.20E+O0 SF L4043-03 41 Ce-144 9.OOE-01 7.80E+00 2.70E+0O SF L4043-03 41 Co-57 7.OOE-01 1.lOE+O0 3.60E+OO SF L4043-03 41 Co-58 1.20E+O0 1.40E+00 4.70E3+00 SF L4043-03 41 Co-60 -1.90E+00 2.20E+00 8.30E+O0 SF L4043-03 41 Cr-51 5.OOE+O0 1.30E+01 4.40E+O1 SF L4043-03 41 Cs-134 7.OOE-0O 1.40E+00 5.OOE+O0 SF L4043-03 41 Cs-137 -7.OOE-0O 1.50E+O0 5.70E+O0 SF L4043-03 41 Fe-59 -2.80E+O0 3.60E+00 1.40E+01 SF L4043-03 41 1-13I 1.50E-0O 2.40E-01 9.10E-01 SF L4043-03 41 K-40 1.32E+03 6.30E+OI 7.OOE+0I SF L4043-03 41 La- 140 -5.OOE-01 2.30E+00 9.40E+00 SF L4043-03 41 Mn-54 O.OOE+00 1.50E+00 5.40E+O0 SF L4043-03 41 Nb-95 -1.90E+OO 1.70E+O0 6.70E+00 SF L4043-03 41 Ru-103 -1.IOE+O0 1.40E+00 5.40E+00 SF L4043-03 41 Ru-106 6.OOE+00 1.50E+OI 5.10E+01 SF L4043-03 41 Sb-124 -1.50E+00 3.10E+O0 1.30E+01 SF L4043-03 41 Sb-125 -4.80E+O0 3.50E+OO 1.30E+01 SF L4043-03 41 Se-75 6.OOE-01 1.80E+00 6.40E+O0 SF L4043-03 41 Zn-65 2.40E+0O 3.90E+O0 1.30E+01 SF L4043-03 41 Zr-95 2.20E+00 2.50E+00 8.60E+00 LF L4043-04 41 AcTh-228 -5.OOE-OI 4. 1OE+00 1.50E+I01 LF L4043-04 41 Ag-108m -2.20E-0I 8.90E-OI 3.20E+00 LF L4043-04 41 Ag-lOrm -2.00E-O1 1.40E+00 5. 1OE+00 LF L4043-04 41 Ba-140 0.OOE+O0 1.60E+O0 5.90E+00 LF L4043-04 41 Be-7 6.80E+00 8.50E+00 2.90E+0O LF L4043-04 41 Ce-141 -3.70E+00 1.80E+00 6.60E+O0 LF L4043-04 41 Ce-144 -1.60E+O0 7.OOE+00 2.40E+0O LF L4043-04 41 Co-57 5.60E-01 9.00E-01 3.10E+00 LF L4043-04 41 Co-58 -1.60E+O0 l.OOE+00 3.90E+OO LF L4043-04 41 Co-60 2.60E+00 1.40E+00 4.70E+OO LF L4043-04 41 Cr-51 -7.50E+O0 9.90E+00 3.50E+01 LF L4043-04 41 Cs-134 -2.00E+00 l.OOE+00 4.IOE+OO
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-131
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
LF L4043-04 41 Cs-137 9.00E-01 1.20E+00 3.90E+00 LF L4043-04 41 Fe-59 5.00E-01 2.50E+00 8.70E+00 LF L4043-04 41 1-131 -4.OOE-02 2.40E-01 9.90E-0O LF L4043-04 41 K-40 1.43E+03 4.70E+01 4.90E+01 LF L4043-04 41 La-140 0.OOE+00 1.80E+00 6.80E+00 LF L4043-04 41 Mn-54 -3.20E-01 9.80E-01 3.60E+O0 LF L4043-04 41 Nb-95 -7.00E-01 1.IO0+00 4.10E+00 LF L4043-04 41 Ru-103 -I.IOE+00 1.IOE+00 4.00E+00 LF L4043-04 41 Ru-106 -1.82E+01 9.90E+00 3.70E+01 LF L4043-04 41 Sb-124 O.OOE+00 2.60E+00 9.50E+00 LF L4043-04 41 Sb-125 -9.OOE-01 2.80E+00 9.802+00 LF L4043-04 41 Se-75 -2.30E+00 1.40E+00 5.1OE+00 LF L4043-04 41 Zn-65 3.602+00 3.60E+00 1.202+01 LF L4043-04 41 Zr-95 1.60E+00 1.70E+00 5.802+00 WF L4043-05 41 Aclb-228 -1.40E+00 4.00E+00 1.50E+01 WF L4043-05 41 Ag-108m -7.40E-01 8.60E-01 3.20E+00 WF L4043-05 41 Ag-l lOnm 1.IOE+00 1.60E+00 5.50E+00 WF L[4043-05 41 Ba-140 -1.30E+00 1.60E+00 6.402+00 WF L4043-05 41 Be-7 O.OOE+00 8.402+00 3.002+01 WF L4043-05 41 Ce-141 1.20E+00 2.10E+00 7.102+00 WF L4043-05 41 Ce-144 3.00E+00 7.30E+00 2.50E+01 WF L4043-05 41 Co-57 -6.00E-02 9.802-01 3.40E+00 WF L4043-05 41 Co-58 0.00+00 1.102+00 3.90E+00 WF L4043-05 41 Co-60 1.20E+00 1.502+00 5.302+00 WF L4043-05 41 Cr-51 -I.OOE+01 1.102+01 4.002+01 WF L4043-05 41 Cs-134 -8.00E-01 1.202+00 4.602+00 WF L4043-05 41 Cs-137 3.002+00 1.20E+00 3.802+00 WF L4043-05 41 Fe-59 -2.60E+00 2.80E+00 1.10E+01 WF L4043-05 41 1-131 2.60E-01 2.70E-01 9.902-01 WF [4043-05 41 K-40 1.33E+03 5.102+01 5.20E+01 WF L4043-05 41 La-140 -1.50E+00 1.80E+00 7.402+00 WF L4043-05 41 Mn-54 -1.80E+00 1.IO0+00 4.202+00 WF L4043-05 41 Nb-95 -8.00E-01 1.20E+00 4.502+00 WF L4043-05 41 Ru-103 1.80E+00 1.30E+00 4.30E+00 WF L4043-05 41 Ru-106 -5.00E+00 1.00E+01 3.702+01 WF L4043-05 41 Sb-124 I.OOE+00 2.102+00 7.70E+00 WF L4043-05 41 Sb-125 -3.00E-01 3.002+00 1.102+01 WF L4043-05 41 Se-75 4.00E-01 1.402+00 4.90E+00 WF L4043-05 41 Zn-65 -3.20E+00 3.20E+00 1.20E+01 WF L4043-05 41 Zr-95 3.30E+00 2.202+00. 7.20E+00
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-132
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
GTF L4185-01 43 AcTh-228 5.OOE-0O 5.30E+00 1.80E+01 GTF L4185-01 43 Ag-108m 3.1OE-01 8.80E-01 3.OOE+00 GTF L4185-01 43 Ag-IlOm 2.40E+00 1.501E+00 5.OOE+00 GTF L4185-01 43 Ba-140 2.OOE+00 2.00E+00 6.70E+00 GTF L4185-01 43 Be-7 -1.05E+01 8.70E+00 3.10E+0O GTF L4185-01 43 Ce-141 -3.40E+00 2.40E+00 8. 1OE+00 GTF L4185-01 43 Ce-144 -8.60E+00 5.30E+00 1.80E+0O GTF L4185-01 43 Co-57 -4.90E-0O 6.60E-01 2.30E+0O GTF L4185-01 43 Co-58 l.OOE-01 1. lOE+00 3.80E+00 GTF L4185-01 43 Co-60 2.30E+00 1.60E+00 S.20E+00 GTF L4185-01 43 Cr-51 8.00E-01 9.60E+O0 3.30E+01 GTF L4185-01 43 Cs-134 -7.00E-0O 1.30E3+00 4.50E+00 GTF L4185-01 43 Cs-137 l.OOE+00 1.20E+00 4.00E+00 GTF L4185-01 43 Fe-59 8.00E-01 2.90E+00 9.90E+00 GTF L4185-01 43 1-131 6.40E-0O 3.20E-0O 9.OOE-01 GTF L4185-01 43 K-40 1.41E+03 4.40E+0O 6.50E+01 GTF L4185-01 43 La-140 2.30E+00 2.30E+00 7.70E+00 GTF L4185-01 43 Mn-54 3.00E-01 1.lIOE+00 3.70E+O0 GTF L4185-01 43 Nb-95 -9.OOE-01 1.20E+00 4. 10E+00 GTF L4185-01 43 Ru-103 -1.70E+00 1.lOE+00 3.80E+00 GTF L4185-01 43 Ru-106 2.70E+00 9.90E+00 3.40E+01 GTF L4185-01 43 Sb-124 O.OOE+00 2.90E+00 1.OOE+01 GTF L4185-01 43 Sb-125 5.20E+00 2.70E+00 8.80E+00 GTF LU185-01 43 Se-75 2.20E+00 1.20E+00 4.OOE+00 GTF L4185-01 43 Zn-65 1.50E+00 2.70E+00 9.40E+00 GTF L4185-01 43 Zr-95 -2.50E+00 1.90E+00 6.90E+00 MR L4185-02 43 AcTh-228 1.501E+00 5.OOE+00 1.70E+0O MR L4185-02 43 Ag-108m 2.00E-0O l.OOE+00 3.50E+00 MR L4185-02 43 Ag-I lOm -1.70E+00 1.80E+00 6.30E+00 MR L4185-02 43 Ba-i40 1.60E+00 1.70E+00 5.90E+00 MR L4185-02 43 Be-7 -1.06E+01 9.30E+00 3.30E+01 MR L4185-02 43 Ce-141 -2.10E+00 1.70E+00 5.80E+00 MR L4185-02 43 Ce-144 8.50E+OO 6.60E+00 2.20E+01 MR L4185-02 43 Co-57 -1.20E-01 8.10E-OI 2.80E+00 MR UA185-02 43 Co-58 1.IOE+00 1.20E+00 3.90E+00 MR L4185-02 43 Co-60 -5.OOE-01 1.70E+00 5.90E+00 MR L4185-02 43 Cr-51 1.OOE+00 1.OOE+0O 3.50E+01 MR L4185-02 43 Cs-134 -3.00E-0O l.10E+00 4.OOE+00
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-133
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
MR L4185-02 43 Cs-137 -2.30E+00 1.20E+00 4.40E+O0 MR L4185-02 43 Fe-59 4.OOE-01 2.90E+00 9.90E+O0 MR L4185-02 43 1-131 7.OOE-02 2.10E-01 9.30E-OI MR L4185-02 43 K-40 1.94E+03 5.OOE+01 5.40E+OI MR L4185-02 43 La-140 I.90E+00 2.OOE+00 6.80E+O0 MR L4185-02 43 Mn-54 l.OOE-OI 1.20E+00 4.20E+OO MR L4185-02 43 Nb-95 -1.80E+00 1.40E+00 5.10E+0O MR L4185-02 43 Ru-103 -1.40E+0O l.lOE+OO 4.OOE+OO MR L4185-02 43 Ru-106 -2.00E+OO I.OOE+OI 3.60E+O1 MR L4185-02 43 Sb-124 -1.60E+00 2.60E+00 9.70E+O0 MR L4185-02 43 Sb-125 -4.80E+00 3.OOE+OO 1.1OE+0O MR L4185-02 43 Se-75 2.30E+00 1.50E+00 4.90E+OO MR L4185-02 43 Zn-65 3.80E+00 3.90E+00 1.30E+O1 MR L4185-02 43 Zr-95 -I.OOE+OO 2.10E+00 7.40E+OO SF L4185-03 43 AcTh-228 1.05E+01 5.10E+00 1.70E+O1 SF L4185-03 43 Ag-108m 4.50E-01 9.70E-01 3.30E+O0 SF L4185-03 43 Ag-llim -I.OOE+OO 1.90E+00 6.70E+OO SF L4185-03 43 Ba-140 -1.90E1+00 2.70E+OO 1.OOE+OI SF L4185-03 43 Be-7 l.OOE+OI I.OOE+OI 3.40E+OI SF L4185-03 43 Ce-141 1.20E+00 1.70E+00 5.80E+OO SF L4185-03 43 Ce-144 -1.30E+00 6.OOE+00 2.OOE+O1 SF L4185-03 43 Co-57 -7.90E-01 7.40E-01 2.60E+0O SF L4185-03 43 Co-58 1.40E+00 1.30E+00 4.50E+OO SF L4185-03 43 Co-60 7.OOE-01 1.80E+00 6.1OE+OO SF L4185-03 43 Cr-51 3.20E+01 1.20E+01 3.90E+OI SF L4185-03 43 Cs-134 -3.60E+00 1.50E+00 5.50E+O0 SF L4185-03 43 Cs-137 I.OOE-0 1.30E+00 4.60E+OO SF L4185-03 43 Fe-59 -2.60E+00 3.30E+00 1.20E+OI SF L4185-03 43 1-131 -2.1OE-01 1.20E-01 9.30E-OI SF L4185-03 43 K-40 1.35E+03 4.80E1+01 6.80E+OI1 SF L4185-03 43 La-140 -2.20E+00 3.10E+00 1.20E+O1 SF L4185-03 43 Mn-54 O.OOE+0O 1.40E+00 4.80E+OO SF L4185-03 43 Nb-95 -4.00E-01 1.50E+00 5.30E+0O SF L4185-03 43 Ru-103 -4.00E-01 1.20E+00 4.40E+OO SF L4185-03 43 Ru-106 I.OOE+O0 1.20E+01 4.10E+OI SF L4185-03 43 Sb-124 1.20E+00 3.50E+00 1.20E+O1 SF L4185-03 43 Sb-125 1.50E+00 2.90E+00 9.80E+O0 SF L4185-03 43 Se-75 I.OOE+00 1.50E+00 4.90E+00 SF L4185-03 43 Zn-65 I.OOE+00 4.30E+00 1.50E+0O SF L4185-03 43 Zr-95 -2.60E+00 2.30E+00 8.30E+00
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-134
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
LF L4185-04 43 AcTh-228 -3.20E+00 3.60E+00 1.30E+OI LF L4185-04 43 Ag-108m 3.OOE-02 6.70E-0O 2.30E+0O LF L4185-04 43 Ag-l lOm 4.OOE-0O l .1OE+O0 3.60E+OO LF L4185-04 43 Ba-140 -1.OOE+00 1.40E+00 5.30E+00 LF L4185-04 43 Be-7 4.70E+00 7.20E+00 2.40E+0O LF L4185-04 43 Ce-141 -3.10E+00 2.OOE+00 7.OOE+00 LF L4185-04 43 Ce-144 -1.20E+00 4.30E+00 1.50E+0I LF L4185-04 43 Co-57 4.20E-0O 5.70E-0O 1.90E+00 LF L4185-04 43 Co-58 -1.36E+00 8.80E-0O 3.20E+00 LF L4185-04 43 Co-60 -4.OOE-0O l.OOE+00 3.50E+00 LF L4185-04 43 Cr-51 5.10E+00 8.30E+00 2.80E+0O LF L4185-04 43 Cs-134 5.1OE-0I 8.20E-OI 2.80E+00 LF L4185-04 43 Cs-137 8.20E-01 8.90E-0O 3.OOE+00 LF L4185-04 43 Fe-59 -1.40E+00 2.OOE+OO 7.20E+00 LF L4185-04 43 1-131 3.60E-01 2.80E-0O 9.50E-0I LF LA185-04 43 K-40 1.51E+03 3.50E+01 4.OOE+0I LF L4185-04 43 La-140 -1.80E+00 1.60E+00 6.10E+O0 LF L4185-04 43 Mn-54 1.61E+00 7.80E-O1 2.50E+O0 LF L4185-04 43 Nb-95 -1.09E+00 9.70E-OI 3.50E+00 LF L4185-04 43 Ru-103 -2.80E-0O 8.60E-OI 3.00E+00 LF L4185-04 43 Ru-106 -6.80E+00 8.OOE+00 2.80E+OI LF L4185-04 43 Sb-124 -6.OOE-0O 1.80E+00 6.70E+O0 LF L4185-04 43 Sb-125 -3.70E+O0 2. 1OE+00 7.40E+00 LF L4185-04 43 Se-75 -7. IOE-0O 8.80E-OI 3.10E+00 LF L4185-04 43 Zn-65 2.90E+O0 2.80E+O0 9.OOE+00 LF L4185-04 43 Zr-95 -1.70E+00 1.50E+00 5.50E+00 WF LA185-05 43 AcTh-228 1.40E+00 4.80E+O0 1.60E+0O WF LA185-05 43 Ag-108m -7.10E-0O 7.90E-0O 2.80E+0O WF LA185-05 43 Ag-I lOm -8.OOE-0O 1.50E+O0 5.30E+00 WF L4185-05 43 Ba-140 -3.90E+00 2.20E+00 8.70E+00 WF L4185-05 43 Be-7 1.28E+0O 8.70E+00 2.90E+0O WF LA185-05 43 Ce-141 O.OOE+OO 1.40E+00 4.70E+00 WF L4185-05 43 Ce-144 4.20E+00 4.90E+0O 1.60E+0O WF LA185-05 43 Co-57 8.OOE-02 6.40E-OI 2.20E+00 WF L1A85-05 43 Co-58 -3.OOE-0O . IOE+0O 3.80E+00 WF LA185-05 43 Co-60 l .OE+0O 1.40E+0O 4.90E+00 WF LA185-05 43 Cr-51 -1.50E+0O l.OOE+0O 3.60E+0O WF LA185-05 43 Cs-134 9.OOE-OI 1.20E+00 4.OOE+OO WF LA185-05 43 Cs-137 l .OE+00 1.1 OE+0O 3.80E+O0 WF LA185-05 43 Fe-59 2.60E+00 2.90E+OO 9.70E+O0
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-135
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
WF L4185-05 43 1-131 3.20E-01 2.60E-01 8.80E-0l WF L4185-05 43 K-40 1.34E+03 4.20E+01 5.70E+01 WF L4185-05 43 La-140 -4.50E+00 2.60E+00 1.00E+01 WF L4185-05 43 Mn-54 I.OOE+OO I.IOE+00 3.60E+00 WF L4185-05 43 Nb-95 -1.90E+00 1.50E+00 5.40E+00 WF L4185-05 43 Ru-103 -1.20E+00 1.IOE+00 3.80E+00 WF L4185-05 43 Ru-106 -7.20E+00 9.90E+00 3.50E+01 WF L4185-05 43 Sb-124 -1.60E+00 2.50E+00 9.40E+00 WF L4185-05 43 Sb-125 O.OOE+00 2.60E+00 8.80E+00 WF L4185-05 43 Se-75 -5.00E-01 1.20E+00 4.10E+00 WF L4185-05 43 Zn-65 -3.OOE+00 2.70E+00 9.80E+00 WF L4185-05 43 Zr-95 -9.OOE-01 2.00E+00 7.OOE+00 GTF L4254-01 45 AcTh-228 5.OOE-01 5.40E+00 1.90E+01 GTF L4254-01 45 Ag-108m -5.60E-01 9.90E-01 3.70E+00 GTF L4254-01 45 Ag-ll0m -5.00E-01 1.60E+00 6.00E+00 GTF L4254-01 45 Ba-140 I.OOE-01 1.60E+00 6.20E+00 GTF L4254-01 45 Be-7 9.OOE+00 1.OOE+01 3.50E+01 GTF L4254-01 45 Ce-141 3.60E+00 2.10E+00 6.80E+00 GTF L4254-01 45 Ce-144 -4.00E-01 8.00E+00 2.80E+01 GTF L4254-01 45 Co-57 9.00E-01 1.10E+00 3.60E+00 GTF LA254-01 45 Co-58 -6.00E-01 1.20E+00 4.70E+00 GTF LA254-01 45 Co-60 -1.60E+00 1.70E+00 6.60E+00 GTF L4254-01 45 Cr-51 1.OOE+00 1.20E+01 4.20E+01 GTF L4254-01 45 Cs-134 -1.60E+00 1.20E+00 4.80E+00 GTF L4254-01 45 Cs-137 7.00E-01 1.20E+00 4.30E+00 GTF L4254-01 45 Fe-59 -4.00E-01 2.90E+00 I.IOE+01 GTF L4254-01 45 1-131 2.20E-01 2.40E-01 9.30E-01 GTF U254-01 45 K-40 1.48E+03 5.90E+01 5.90E+01 GTF UA254-01 45 La-140 1.OOE-01 1.80E+00 7.10E+00 GTF U4254-01 45 Mn-54 -4.00E-02 9.70E-01 3.60E+00 GTF L4254-01 45 Nb-95 3.00E-01 1.20E+00 4.40E+00 GTF U4254-01 45 Ru-103 -1.20E+00 1.30E+00 4.80E+00 GTF L4254-01 45 Ru-106 -6.00E+00 1.10E+01 3.90E+01 GTF L4254-01 45 Sb-124 O.OOE+00 2.30E+00 9.20E+00 GTF 14254-01 45 Sb-125 -1.40E+00 3.20E+00 1.20E+01 GTF 14254-01 45 Se-75 6.00E-01 1.40E+00 4.90E+00 GTF UA254-01 45 Zn-65 -2.40E+00 3.20E+00 1.20E+01 GTF 1254-01 45 Zr-95 1.90E+00 2.50E+00 8.80E+00
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-136
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
MR L4254-02 45 AcTh-228 1.50E+O0 8.30E+00 3.OOE+01 MR L4254-02 45 Ag-108m -1.20E+O0 1.SOE+O0 5.SOE+00 MR L4254-02 45 Ag- lOim 1.50E+00 2.40E+00 8.70E+O0 MR L4254-02 45 Ba-140 3. 1OE+00 2.OOE+00 6.60E+00 MR L4254-02 45 Be-7 3.1OE+0I 1.50E+01 4.70E+01 MR L4254-02 45 Ce-141 -5.30E+00 2.40E+00 9.10E+00 MR L4254-02 45 Ce-144 3.20E+O0 9.90E+00 3.40E+0O MR L4254-02 45 Co-57 1.80E+O0 1.20E+00 4.OOE+00 MR L4254-02 45 Co-58 4.OOE-Ol 1.60E+00 6.OOE+00 MR L4254-02 45 Co-60 1.lOE+00 2.90E+O0 I.OOE+01 MR L4254-02 45 Cr-51 -1.30E+0O 1.60E+01 6.OOE+01 MR L4254-02 45 Cs-134 8.OOE-0I 1.80E+00 6.SOE+00 MR L4254-02 45 Cs-137 -1.70E+00 2.10E+00 7.80E+00 MR L4254-02 45 Fe-59 3.80E+00 5.OOE+00 1.70E+01 MR L4254-02 45 1-131 2.OOE-02 1.60E-01 9.20E-01 MR L4254-02 45 K-40 1.95E+03 8.90E+01 8.30E+01 MR L4254-02 45 La-140 3.SOE+00 2.30E+00 7.60E+00 MR L4254-02 45 Mn-54 -1.30E+00 1.70E+00 6.70E+00 MR L4254-02 45 Nb-95 7.OOE-0I 2.OOE+00 7.10E+00 MR L4254-02 45 Ru-103 4.30E+00 1.60E+00 4.70E+00 MR L4254-02 45 Ru-106 6.OOE+00 1.70E+01 5.90E+0O MR L4254-02 45 Sb-124 O.OOE+O0 3.80E+O0 l.SOE+01 MR L4254-02 45 Sb-125 -1.SOE+00 4.10E+00 l .50E+0I MR L4254-02 45 Se-75 1. lOE+00 2.20E+00 7.60E+O0 MR L4254-02 45 Zn-65 -6.SOE+00 4.70E+00 1.90E+0I MR L4254-02 45 Zr-95 -1. IOE+00 3.10E+00 1.20E+0I SF L4254-03 45 AcTh-228 3.SOE+00 4.80E+00 1.70E+O1 SF L4254-03 45 Ag-108m 1.30E+00 1.lOE+00 3.60E+00 SF L4254-03 45 Ag- lOim 3.OOE-0I 2.OOE+00 7.20E+O0 SF L4254-03 45 Ba-140 -2.30E+00 1.90E+00 7.80E+O0 SF L4254-03 45 Be-7 -5.OOE+00 1.lOE+O1 3.90E+O1 SF L4254-03 45 Ce-141 -2.40E+O0 2.20E+00 8.OOE+O0 SF L4254-03 45 Ce-144 1.14E+01 8.90E+00 3.OOE+0O SF L4254-03 45 Co-57 2.30E+O0 1.lOE+O0 3.70E+O0 SF L4254-03 45 Co-58 3.OOE-01 1.30E+00 4.70E+00 SF L4254-03 45 Co-60 3.50E+O0 2.10E+00 6.70E+00 SF L4254-03 45 Cr-SI O.OOE+O0 1.30E+01 4.50E+0I SF L4254-03 45 Cs-134 6.OOE-0I 1.30E+00 4.70E+OO SF L4254-03 45 Cs-137 O.OOE+00 1.30E+00 4.90E+OO SF L4254-03 45 Fe-59 -4.OOE-01 3.40E+00 1.20E+O1
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-137
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
SF L4254-03 45 1-131 9.OOE-02 1.70E-01 7.60E-OI SF L4254-03 45 K-40 1.47E+03 6.10E+01 6.10E+O1 SF L4254-03 45 La-140 -2.60E+00 2.l10E+00 9.OOE+OO SF L4254-03 45 Mn-54 -7.OOE-01 1.40E+00 5. IOE+00 SF L4254-03 45 Nb-95 9.OOE-01 1.20E+00 4.30E+O0 SF L4254-03 45 Ru-103 -1.20E+00 1.30E+00 4.80E+OO SF L4254-03 45 Ru-106 5.OOE+00 1.30E+01 4.50E+OI SF L4254-03 45 Sb-124 1.20E+00 2.60E+00 9.90E+OO SF L4254-03 45 Sb-125 I.90E+00 3.30E+O0 1.IOE+0I SF L4254-03 45 Se-75 3.50E+00 1.80E+00 5.80E+00 SF L4254-03 45 Zn-65 4.OOE-01 3.20E+00 1.20E+OI SF L4254-03 45 Zr-95 -5.OOE-01 2.IOE+00 7.80E+OO LF L4254-04 45 AcTh-228 3.20E+00 5.OOE+00 1.70E+OI LF L4254-04 45 Ag-108m -2.OOE-01 9.60E-01 3.50E+OO LF L4254-04 45 Ag-i lOmn 8.OOE-01 1.60E+00 5.50E+O0 LF L4254-04 45 Ba-140 -2. 1OE+00 1.60E+00 6.70E+O0 LF L4254-04 45 Be-7 I.OOE+01 l.OOE+OI 3.40E+OI LF L4254-04 45 Ce-141 3.70E+00 2.50E+00 8.30E+OO LF L4254-04 45 Ce-144 -1.30E+00 8.OOE+00 2.80E+OI LF L4254-04 45 Co-57 1.40E+0O I.1OE+OO 3.50E+OO LF L4254-04 45 Co-58 7.OOE-01 1.20E+00 4.20E+OO LF L4254-04 45 Co-60 -1.30E+00 1.50E+00 5.70E+O0 LF L4254-04 45 Cr-51 I.OOE+01 I.IOE+01 3.70E+0O LF L4254-04 45 Cs-134 -1.60E+00 1.30E+00 5.OOE+00 LF L4254-04 45 Cs-137 6.OOE-01 1.20E+00 4.20E+OO LF L4254-04 45 Fe-59 -3.20E+00 2.90E+O-O 1.IOE+OI LF L4254-04 45 1-131 8.OOE-01 3.80E-01 9.OOE-01 LF L4254-04 45 K-40 1.51E+03 5.60E+01 5.80E+01 LF L4254-04 45 La-140 -2.50E+00 1.80E+00 7.70E+OO LF L4254-04 45 Mn-54 -I.OOE-0I l.IOE+00 4.OOE+OO LF L4254-04 45 Nb-95 - 1.40E+00 1.20E+00 4.70E+OO LF L4254-04 45 Ru-103 -1.60E+00 1.30E+00 5.OOE+OO LF L4254-04 45 Ru-106 -9.OOE+00 1.20E+01 4.50E+0O LF L4254-04 45 Sb-124 -L.OOE-01 2.50E+00 9.70E+OO LF L4254-04 45 Sb-125 -2.1OE+00 2.90E+OO 1.IOE+0I LF L4254-04 45 Se-75 I.OOE-OI 1.70E+00 5.70E+00 LF L4254-04 45 Zn-65 -2.40E+00 3.60E+00 1.30E+0O LF L4254-04 45 Zr-95 -4.OOE-01 2.OOE+00 7.30E+OO WF L4254-05 45 AcTh-228 I.IOE+OO 4.60E+00 1.70E+01 WF L4254-05 45 Ag-108m -2.OOE-01 I.IOE+0O 3.80E+00
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-138
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
WF L4254-05 45 Ag-l lOm I .OOE-0O 1.30E+00 5.OOE+00 WF L4254-05 45 Ba-140 -1.70E+00 1.30E+00 6.OOE+O0 WF L4254-05 45 Be-7 -1.04E+01 9.1OE+00 3.50E+0O WF LU254-05 45 Ce-141 O.OOE+00 2.OOE+00 7.10E+00 WF L4254-05 45 Ce-144 9.OOE-01 8.10E+00 2.80E+0O WF L4254-05 45 Co-57 1.50E+00 l.IOE+00 3.60E+00 WF LU254-05 45 Co-58 -1.40E+O0 1.20E+00 4.90E+00 WF L4254-05 45 Co-60 1.80E+00 1.30E+00 4.30E+00 WF L4254-05 45 Cr-51 -7.OOE+00 l.lOE+01 4.OOE+0O WF L4254-05 45 Cs-134 3.OOE-0O 1.30E+00 4.70E+00 WF L4254-05 45 Cs-137 2.OOE+O0 1.30E+00 4.20E+O0 WF L4254-05 45 Fe-59 -1.50E+00 3.30E+00 1.20E+OI WF L4254-05 45 1-131 2.30E-0O 2.50E-01 9.60E-01 WF L4254-05 45 K-40 1.53E+03 6.OOE+01 5.90E+0I WF L4254-05 45 La-140 -2.OOE+00 1.50E+00 6.90E+O0 WF L4254-05 45 Mn-54 9.OOE-01 1.20E+00 4.20E+O0 WF L4254-05 45 Nb-95 6.OOE-01 1.20E+00 4.40E+O0 WF L4254-05 45 Ru-103 -3.OOE-0l 1.30E+00 4.70E+O0 WF L4254-05 45 Ru-106 -9.OOE+00 1.20E+01 4.40E+OI WF L4254-05 45 Sb-124 -4.10E+00 2.50E+O0 1.1OE+OI WF L4254-05 45 Sb-125 -3.OOE-0O 3.30E+00 1.20E+OI WF L4254-05 45 Se-75 4.OOE-01 1.40E+00 4.80E+00 WF L4254-05 45 Zn-65 -8.OOE-0O 3.40E+00 1.20E+0O WF L4254-05 45 Zr-95 -5.OOE-0O l.90E+00 7.10E+00 GTF L4372-01 47 AcTh-228 4.90E+00 5.OOE+00 1.70E+I0 GTF L4372-01 47 Ag-108m 7.30E-0I 9.20E-01 3.1OE+O0 GTF L4372-01 47 Ag- lOim 7.OOE-01 l.90E+00 6.70E+O0 GTF L4372-01 47 Ba-140 2.30E+00 2.60E+00 8.90E+O0 GTF L4372-01 47 Be-7 l .05E+0O 9.70E+00 3.20E+0O GTF L4372-01 47 Ce-141 l.OOE-0I 1.70E+00 5.70E+O0 GTF L4372-01 47 Ce-144 4.50E+00 6.OOE+00 2.OOE+0I GTF L4372-01 47 Co-57 -I.50E-0O 7.10E-01 2.40E+OO GTF L4372-01 47 Co-58 -1.70E+00 1.20E+00 4.30E+00 GTF L4372-01 47 Co-60 1.20E+O0 1.70E+00 5.70E+O0 GTF L4372-01 47 Cr-51 -6.OOE+O0 l.lOE+0O 3.80E+01 GTF L4372-01 47 Cs-134 1.30E+O0 1.20E+00 4. IOE+O0 GTF L4372-01 47 Cs-137 1.20E+O0 1.30E+00 4.20E+OO GTF L4372-01 47 Fe-59 4.50E+00 3.20E+00 I.IOE+OI
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-139
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
GTF L4372-01 47 1-131 4.00E-02 1.40E-01 7.50E-0O GTF L4372-01 47 K-40 1.44E+03 4.80E+01 6.30E+01 GTF L4372-01 47 La-140 2.70E+00 3.00E+00 I.OOE+01 GTF L4372-01 47 Mn-54 I.OOE+00 1.40E+00 4.60E+00 GTF L4372-01 47 Nb-95 1.30E+00 1.40E+00 4.60E+00 GTF L4372-01 47 Ru-103 -2.50E+00 1.30E+00 4.60E+00 GTF L4372-01 47 Ru-106 -2.40E+01 1.102+01 4.10E+OI GTF L4372-01 47 Sb-124 4.40E+00 3.10E+00 1.00E+01 GTF L4372-01 47 Sb- 125 -2.40E+00 2.80E+00 1.00E+01 GTF L4372-01 47 Se-75 -7.OOE-01 1.40E+00 4.70E+00 GTF L4372-01 47 Zn-65 -2.20E+00 3.30E+00 1.20E+01 GTF L4372-01 47 Zr-95 -5.OOE-01 2.20E+00 7.60E+00 MR L4372-02 47 AcTh-228 1.60E+00 7.20E+00 2.50E+01 MR L4372-02 47 Ag-108m -1.04E+00 8.90E-01 3.20E+00 MR L4372-02 47 Ag-l lOm -3.00E+00 1.80E+00 6.50E+00 MR L4372-02 47 Ba-140 3.10E+00 2.10E+00 7.10E+00 MR L4372-02 47 Be-7 -4.20E+00 9.40E+00 3.30E+0I MR L4372-02 47 Ce-141 -2.30E+00 2.70E+00 9.30E+00 MR L4372-02 47 Ce-144 3.80E+00 5.80E+00 1.90E+01 MR LA372-02 47 Co-57 8.70E-01 7.50E-01 2.50E+00 MR L4372-02 47 Co-58 3.00E-01 1.20E+00 4.30E+00 MR L4372-02 47 Co-60 -1.80E+00 1.70E+00 6.30E+00 MR L4372-02 47 Cr-SI 1.00E+01 1.10E+01 3.80E+01 MR L4372-02 47 Cs-134 1.50E+00 1.30E+00 4.40E+00 MR L4372-02 47 Cs-137 2.40E+00 1.40E+00 4.50E+00 MR L4372-02 47 Fe-59 O.OOE+00 3.302+00 1.20E+01 MR L4372-02 47 1-131 -3.00E-02 1.30E-01 8.40E-01 MR L4372-02 47 K-40 1.81E+03 5.302+01 6.40E+01 MR L4372-02 47 La-140 3.60E+00 2.50E+00 8.10E+00 MR L4372-02 47 Mn-54 2.70E+00 1.40E+00 4.40E+OO MR L4372-02 47 Nb-95 -3.00E-01 1.50E+00 5.102E+O MR L4372-02 47 Ru-103 -3.00E-01 1.30E+00 4.50E+00 MR L4372-02 47 Ru-106 5.00E+00 1.1OE+01 3.702+01 MR L4372-02 47 Sb-124 2.00E+00 3.10E+00 1.10E+01 MR L4372-02 47 Sb-125 0.OOE+00 3.002+00 I.OOE+01 MR L4372-02 47 Se-75 -1.60E+00 1.60E+00 5.40E+00 MR L4372-02 47 Zn-65 -7.90E+00 3.302+00 1.20E+01 MR L4372-02 47 zr-95 2.60E+00 2.30E+00 7.50E+00 SF L4372-03 47 AcTh-228 -9.OOE-01 7.20E+00 2.502+01 SF L4372-03 47 Ag-108m 1.60E+00 1.40E+00 4.602+00
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-140
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
SF L4372-03 47 Ag-ll0m -5.OOE-01 2.70E+00 9.60E+00 SF L4372-03 47 Ba-140 5.20E+00 2.90E+00 9.20E+00 SF L4372-03 47 Be-7 3.10E+01 1.60E+01 5.10E+0O SF L4372-03 47 Ce-141 -4.OOE-01 3.20E+00 1.lOE+0O SF L4372-03 47 Ce-144 -1.OOE+00 I.IOE+0I 3.70E+0O SF L4372-03 47 Co-57 8.OOE-01 1.40E+00 4.60E+00 SF L4372-03 47 Co-58 2.80E+00 1.70E+00 5.60E+00 SF LA372-03 47 Co-60 -1.60E+00 2.10E+00 7.70E+00 SF L4372-03 47 Cr-51 7.OOE+00 1.80E+01 6.OOE+0O SF L4372-03 47 Cs-134 7.OOE-01 1.70E+00 6.1OE+OO SF L4372-03 47 Cs-137 5.OOE-O1 1.90E+00 6.40E+OO SF L4372-03 47 Fe-59 -1.09E+01 4.30E+00 1.70E+O1 SF L4372-03 47 1-131 2.20E-01 2.10E-01 7.90E-01 SF L4372-03 47 K-40 1.55E+03 6.60E+01 9.40E+01 SF L4372-03 47 La-140 6.OOE+00 3.30E+OO I.lOE+OI SF [4372-03 47 Mn-54 2.50E+00 1.70E+00 5.50E+OO SF [4372-03 47 Nb-95 3.70E+OO l.90E+00 6.20E+OO SF [A372-03 47 Ru-103 1.30E+.00 2.1OE+00 7.30E+OO SF L4372-03 47 Ru-106 -I.OOE+01 1.60E+01 5.60E+0O SF L4372-03 47 Sb-124 -2.10E+00 4.50E+00 1.70E+01 SF L4372-03 47 Sb-125 -3.80E+00 4.OOE+00 1.40E+O1 SF L4372-03 47 Se-75 -1.50E+00 2.30E+00 7.90E+00 SF [4372-03 47 Zn-65 1.65E+01 7.OOE+00 2.30E+0O SF L4372-03 47 Zr-95 -6.OOE-01 3.OOE+00 l.lOE+0O LF L4372-04 47 AcTh-228 1.28E+01 5.30E+00 1.70E+0O LF [4372-04 47 Ag-108m -1.90E+00 I.IOE+00 4.1OE+00 LF L4372-04 47 Ag-I Orm 9.OOE-01 1.80E+00 6.30E+00 LF L4372-04 47 Ba-140 -3.60E+00 2.30E+00 9.30E+00 LF L4372-04 47 Be-7 -1.30E+OI I.IOE+0 4.10E+0 LF L4372-04 47 Ce-141 1.40E+00 2.OOE+00 6.90E+00 LF L4372-04 47 Ce-144 -7.40E+00 7.OOE+00 2.SOE+0I LF L4372-04 47 Co-57 L.IOE-01 9.30E-01 3.20E+00 LF [4372-04 47 Co-58 -1.60E+00 1.30E+00 4.70E+00 LF L4372-04 47 Co-60 3.70E+00 1.60E+00 4.90E+00 LF L4372-04 47 Cr-51 -2.40E+01 1.40E+01 4.90E+0I LF L4372-04 47 Cs-134 -4.OOE-01 1.40E+00 5.OOE+00 LF L4372-04 47 Cs-137 -I.OOE+00 1.40E+00 5.10E+00 LF L4372-04 47 Fe-59 -1.80E+00 3.1OE+00 I.IOE+0O LF L4372-04 47 1-131 -1.09E-01 1.80E-02 8.20E-0O LF L4372-04 47 K-40 1.45E+03 5.30E+01 6.90E+0I
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-141
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
LF L4372-04 47 La-140 -4.20E+00 2.70E+00 .I1OE+01 LF L4372-04 47 Mn-54 -5.00E-01 1.30E+00 4.80E+00 LF L4372-04 47 Nb-95 -1.30E+00 1.70E+00 6.10E+00 LF L4372-04 47 Ru-103 -2.70E+00 1.50E+00 5.40E+00 LF L4372-04 47 Ru-106 9.00E+00 1.20E+01 4.30E+01 LF L4372-04 47 Sb-124 1.80E+00 3.00E+00 I.1OE+01 LF L4372-04 47 Sb-125 -4.10E+00 3.40E1+00 1.20E+01 LF L4372-04 47 Se-75 -I.10E+00 1.60E1+00 5.60E+00 LF L4372-04 47 Zn-65 -2.60E+00 3.50E+00 1.30E+01 LF L4372-04 47 Zr-95 -4.70E+00 2.40E+00 9.10E+OO WF L4372-05 47 AcTh-228 2.10E+00 5.202+00 1.80E+01 WF L4372-05 47 Ag-108m 1.50E+00 I.OOE+00 3.40E+00 WF L4372-05 47 Ag-l lOm 3.00E+00 1.90E+00 6.20E+00 WF LA372-05 47 Ba-140 O.OOE+0O 2.20E+00 8.10E+00 WF L4372-05 47 Be-7 1.20E+0I I.IOE+0I 3.80E+01 WF L4372-05 47 Ce-141 1.70E+00 2.40E+00 8.00E+O00 WF L4372-05 47 Ce-144 -I.OOE+00 7.50E+00 2.60E+01 WF L4372-05 47 Co-57 -2.68E+00 9.402-01 3.40E+00 WF L4372-05 47 Co-58 -6.00E-01 1.50E+00 5.20E+00 WF L4372-05 47 Co-60 2.20E+00 1.802+00 6.10E+00 WF L4372-05 47 Cr-51 9.00E+00 1.30E+01 4.30E+01 WF L4372-05 47 Cs-134 -2.50E+00 1.602+00 5.80E+00 WF L4372-05 47 Cs-137 1.80E+00 1.60E+00 5.202+00 WF L4372-05 47 Fe-59 3.80E+00 3.502+00 1.20E+01 WF L4372-05 47 1-131 1.00-01 1.80E-01 8.20E-01 WF L4372-05 47 K-40 1.42E+03 5.20E+01 7.10E+01 WF L4372-05 47 La-140 0.00+00 2.50E+00 9.30E+00 WF L4372-05 47 Mn-54 -2.00E+00 1.40E+00 5.30E+00 WF L4372-05 47 Nb-95 -4.20E+00 1.60E+00 6.30E+OO WF L4372-05 47 Ru-103 -1.102+00 1.40E+00 4.90E+00 WF L4372-05 47 Ru-106 -1.OOE+OI 1.30E+01 4.60E+01 WF L4372-05 47 Sb-124 -3.90E+00 3.30E+00 1.30E+01 WF L4372-05 47 Sb-125 1.40E+00 3.20E+00 1.10+01 WF L4372-05 47 Se-75 -3.00E-01 1.702+00 5.802+00 WF L4372-05 47 Zn-65 -3.90E+00 3.80E+00 1.40E+01 WF L4372-05 47 Zr-95 -2.90E+00 2.40E+00 8.902+00 GTF L4468-01 49 AcTh-228 6.00E-01 8.30E+00 2.90E+01 GTF L4468-01 49 Ag-108m 1.OOE+00 1.40E+00 4.90E+00
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-142
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
GTF L4468-01 49 Ag-l lOrn -3.40E+00 2.60E+00 9.80E+00 GTF L4468-01 49 Ba-140 -2.60E+00 2.70E+00 1.IOE+0O GTF L4468-01 49 Be-7 -I.IOE+0O 1.70E+01 5.90E+0O GTF IA468-01 49 Ce-141 -5.50E+00 3.OOE+00 L.OOE+0O GTF L4468-01 49 Ce-144 2.40E+0O 1.1OE+0 3.60E+01 GTF L4468-01 49 Co-57 -9.OOE-0O 1.40E+00 4.90E+00 GTF LA468-01 49 Co-58 1.20E+00 1.80E+00 6.40E+00 GTF LA468-01 49 Co-60 -2.10E+00 2.10E+00 8.OOE+00 GTF L4468-01 49 Cr-51 l.OOE+00 1.80E+01 6.10E+01 GTF LA468-01 49 Cs-134 -2.OOE-0O 2.1OE+00 7.50E+00 GTF L4468-01 49 Cs-137 -5.OOE-0O l.90E+00 6.80E+00 GTF L4468-01 49 Fe-59 7.OOE-0O 4.20E+00 1.50E+0O GTF LU468-01 49 1-131 3.OOE-0I 2.70E-01 9.50E-0O GTF LA468-01 49 K40 1.42E+03 7.OOE+0 I.OOE+02 GTF L4468-01 49 La-140 -3.OOE+00 3.1OE+00 1.20E+01 GTF LU468-01 49 Mn-54 8.OOE-0O 1.90E+00 6.50E+00 GTF U4468-01 49 Nb-95 -3.90E+00 2.30E+00 8.60E+00 GTF L4468-01 49 Ru-103 O.OOE+00 1.90E+00 6.60E+00 GTF UA468-01 49 Ru-106 2.30E+0O 1.70E+01 5.50E+01 GTF L4468-01 49 Sb-124 -4.70E+00 5. IOE+00 2.OOE+01 GTF U4468-01 49 Sb-125 3.40E+00 4.60E+00 1.60E+01 GTF LA468-01 49 Se-75 l .OOE-0O 2.30E+00 7.90E+00 GTF U4468-01 49 Zn-65 -8.90E+00 4.60E+00 1.80E+O1 GTF U4468-01 49 Zr-95 -2.70E+00 3.40E+00 1.20E+0O MR U4468-02 49 AcTh-228 -3.60E+00 5.70E+00 2.10E+0O MR 1U468-02 49 Ag-108m 1.70E+00 1.20E+00 3.80E+00 MR L4468-02 49 Ag-lOrm -1.70E+00 l.90E+00 7.20E+00 MR L4468-02 49 Ba-140 -6.OOE-01 2.OOE+00 7.50E+00 MR LU468-02 49 Be-7 7.OOE+00 1.lOE+0 3.80E+01 MR 14468-02 49 Ce-141 6.OOE-0I 2.10E+00 7.20E+00 MR 14468-02 49 Ce-144 6.30E+00 7.90E+00 2.60E+0O MR L4468-02 49 Co-57 -I.OOE-01 l.OOE+00 3.60E+00 MR 1A468-02 49 Co-58 -2.OOE-0O 1.30E+00 4.90E+00 MR LA468-02 49 Co-60 2.60E+00 2.OOE+00 6.60E+00 MR U4468-02 49 Cr-51 1.IOE+OI 1.30E+01 4.40E+0O MR 14468-02 49 Cs-134 1.50E+00 1.50E+00 5.1OE+O0 MR 14468-02 49 Cs-137 1.90E+00 1.70E+00 5.60E+00 MR U4468-02 49 Fe-59 -6.80E+00 3.50E+00 1.40E+0O MR L4468-02 49 1-131 4.80E-01 2.80E-01 7.50E-01 MR U4468-02 49 K-40 2.01E+03 6.40E+01 7.10E+0I
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-143
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
MR L4468-02. 49 La-140 -7.00E-01 2.30E+00 8.70E+00 MR L4468-02 49 Mn-54 -1.50E+00 I .SOE+00 5.40E+00 MR L4468-02 49 Nb-95 -2.80E+00 1.60E+00 6.10E+00 MR L4468-02 49 Ru-103 -1.50E+00 1.40E+00 5.IOE+00 MR L4468-02 49 Ru-106 -4.OOE+00 1.30E+01 4.60E+01 MR L4468-02 49 Sb-124 4.50E+00 3.10E+00 L.OOE+0O MR L4468-02 49 Sb-125 -2.40E+00 3.40E+00 1.20E+01 MR L4468-02 49 Se-75 8.OOE-01 1.80E+00 6.20E+00 MR L4468-02 49 Zn-65 -6.20E+00 3.50E+00 1.30E+0O MR L4468-02 49 Zr-95 7.OOE-01 2.50E+00 8.60E+00 SF L4468-03 49 AcTh-228 -2.OOE+00 5.50E+00 2.00E+01 SF L4468-03 49 Ag-108m 9.00E-01 I.IOE+00 3.90E+00 SF L4468-03 49 Ag-l lOm -6.20E+00 1.80E+00 7.50E+00 SF L4468-03 49 Ba-140 2.60E+00 1.90E+00 6.20E+00 SF L4468-03 49 Be-7 -1.30E1+01 1.20E+01 4.40E+0I SF L4468-03 49 Ce-141 3.80E+00 2.20E+00 7.20E+00 SF L4468-03 49 Ce-144 4.OOE+00 7.40E+00 2.50E+01 SP L4468-03 49 Co-57 -6.40E-01 9.10E-01 3.20E+0O SF L4468-03 49 Co-58 1.30E+00 1.40E+00 4.90E+00 SF L4468-03 49 Co-60 -2.00E-OI I.90E+00 6.60E+O0 SF L4468-03 49 Cr-51 -3.00E+00 1.40E+01 4.80E+01 SF LA468-03 49 Cs-134 -2.10E+00 1.40E+00 5.60E+00 SF L4468-03 49 Cs-137 I.90E+00 1.50E+00 5.00E+00 SF L4468-03 49 Fe-59 -6.OOE+00 3.10E+00 1.20E+I01 SF L4468-03 49 1-131 2.30E-01 2.30E-01 8.30E-0O SF L4468-03 49 K-40 1.22E+03 5.60E+01 8.OOE+0I SF L4468-03 49 La-140 3.00E+00 2.20E+00 7.20E+00 SF L4468-03 49 Mn-54 3.00E-01 1.30E+00 4.50E+00 SF L4468-03 49 Nb-95 -3.30E+00 1.60E+00 6.30E+00 SF L4468-03 49 Ru-103 3.OOE-01 1.40E+00 5.OOE+00 SF L4468-03 49 Ru-106 2.OOE+00 1.30E+01 4.70E+0I SF L4468-03 49 Sb-124 6.00E-01 2.90E+00 1.1OE+01 SF L4468-03 49 Sb-125 -2.20E+00 3.50E+00 1.30E+01 SF L4468-03 49 Se-75 -1.60E+00 1.50E+00 5.60E+00 SF L4468-03 49 Zn-65 -4.90E+00 3.60E+00 1.40E+01 SF L4468-03 49 Zr-95 -9.OOE-01 2.90E3+00 I.OOE+01 LF L4468-04 49 AcTh-228 -4.70E+00 5.30E+00 I.90E+0I LF L4468-04 49 Ag-108m -I.OOE-01 l.IOE+00 3.80E+00 LF L4468-04 49 Ag-I lOm -2.OOE-01 1.80E+00 6.20E+00 LF L4468-04 49 Ba-140 3.80E+00 2.40Ei+00 7.70E+00
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-144
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
LF L4468-04 49 Be-7 -8.OOE+00 I.IOE+01 3.80E+01 LF L4468-04 49 Ce-141 2.70E+00 2.50E+00 8.40E+00 LF L4468-04 49 Ce-144 -1 .08E+OI 7.40E+00 2.60E+0O LF L4468-04 49 Co-57 8.20E-01 9.30E-01 3.10E+00 LF L4468-04 49 Co-58 l1.OOE-OI 1.30E+00 4.70E+00 LF L4468-04 49 Co-60 -3.OOE-OI 1.80E+00 6.30E+00 LF L4468-04 49 Cr-51 1.40E+OI 1.30E+01 4.30E+0I LF L4468-04 49 Cs-134 -I .OOE-01 1.30E+00 4.60E+00 LF L4468-04 49 Cs-137 1.90E+OO 1.40E+00 4.60E+00 LF L4468-04 49 Fe-59 1.70E+00 3.50E+00 1.20E+0I LF L4468-04 49 1-131 2.OOE-OI 2.OOE-01 7.60E-OI LF L4468-04 49 K-40 1.41E+03 5.OOE+0 7.10E+0I LF L4468-04 49 La-140 4.40E+00 2.70E+00 8.90E+00 LF L4468-04 49 Mn-54 7.OOE-0O 1.30E+00 4.40E+00 LF L4468-04 49 Nb-95 -3.90E+00 1.70E+00 6.20E+00 LF L4468-04 49 Ru-103 -2.10E+00 1.40E+00 5.IOE+00 LF L4468-04 49 Ru-106 9.OOE+00 1.20E+01 4.10E+0O LF L4468-04 49 Sb-124 4.20E+00 2.90E+00 9.50E+O0 LF L4468-04 49 Sb-125 -8.OOE-0O 3.1OE+00 I.lOE+0O LF L4468-04 49 Se-75 -2.00E+00 1.60E+00 5.60E+00 LF L4468-04 49 Zn-65 2.90E+00 4.70E+00 1.60E+OI LF L4468-04 49 Zr-95 3.60E+00 2.IOE+00 7.00E+00 WF L4468-05 49 AcTh-228 9.40E+00 4.OOE+00 1.30E+0I WF L4468-05 49 Ag-108m 3.40E-OI 7.70E-01 2.60E+00 WF 1A468-05 49 Ag-i lOm -2.OOE-OI 1.40E+00 4.90E+00 WF L4468-05 49 Ba-140 3.00E-OI 1.60E+00 5.60E+00 WF L4468-05 49 Be-7 2.40E+00 7.OOE+00 2.40E+OI WF L4468-05 49 Cc-141 2.OOE-OI 1.20E+00 4.20E+00 WF L4468-05 49 Cc-144 6.40E+00 4.60E+00 I.50E+01 WF L4468-05 49 Co-57 -1.30E-0O 5.80E-01 2.OOE+00 WF L4468-05 49 Co-58 2.OOE-02 9.70E-01 3.40E+00 WF L4468-05 49 Co-60 2.20E+00 1.30E+00 4.30E+00 WF L4468-05 49 Cr-SI 5.50E+00 8.10E+00 2.70E+0I WF L4468-05 49 Cs-134 1.30E+00 l.OOE+00 3.50E+00 WF L4468-05 49 Cs-137 -I.OOE+OO l.lOE+00 3.80E+00 WF L4468-05 49 Fe-59 3.90E+00 2.40E+00 8.OOE+00 WF L4468-05 49 1-131 5.40E-0I 3.20E-01 8.20E-OI WF L4468-05 49 K-40 1.34E+03 3.90E+01 5.80E+0I WF L4468-05 49 La-140 4.00E-01 1.80E+00 6.40E+00 WF L4468-05 49 Mn-54 6.OOE-0O 1.lOE+00 3.80E+00
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-145
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std; Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
WF L4468-05 49 Nb-95 -4.60E-01 9.70E-01 3.40E+00 WF L4468-05 49 Ru-103 -7.90E-01 9.60E-01 3.30E+00 WF L4468-05 49 Ru-106 -4.20E+00 8.60E+00 3.00E+0O WF L4468-05 49 Sb-124 3.OOE-01 2.40E1+00 8.70E+00 WF L4468-05 49 Sb-125 -2.OOE-01 2.30E+00 7.90E+O0 WF L4468-05 49 Se-75 -9.OOE-OI I.IOE+0O 3.60E+00 WF L4468-05 49 Zn-65 2.20E+00 3.20E+00 I.OOE+0O WF L4468-05 49 Zr-95 5.00E-01 1.70E+00 5.80E+0O GTF L4546-01 51 AcTh-228 -1.03E+01 7.1OE+00 2.70E+01 GTF L4546-01 51 Ag-108m -1.90E+00 1.50E+00 5.40E+00 GTF L4546-01 51 Ag-l lOm -8.OOE-01 2.30E+00 8.50E+00 GTF L4546-01 51 Ba-140 2.OOE+00 2.70E+00 9.50E+00 GTF L4546-01 51 Be-7 8.00E+00 1.30E+01 4.50E+0O GTF L4546-01 51 Ce-141 -2.30E+00 2.40E+00 8.20E+00 GTF L4546-01 51 Ce-144 -5.OOE-01 7.50E+00 2.60E+OI GTF LA546-01 51 Co-57 1.52E+00 9.90E-01 3.30E+00 GTF L4546-01 51 Co-58 -1.20E+00 1.70E+00 6.20E+OO GTF L4546-01 51 Co-60 6.00E-01 2.40E+00 8.30E+OO GTF L4546-01 51 Cr-51 -1.20E+01 1.40E+01 5.OOE+OI GTF L4546-01 51 Cs-134 I.OOE-OI 1.7E+00 6.20E+0O GTF L4546-01 51 Cs-137 O.OOE+OO 1.90E+00 6.70E+OO GTF L4546-01 51 Fe-59 3.30E+00 3.90E+00 1.40E+01 GTF L4546-01 51 1-131 1.04E-01 7.40E-02 2.40E-01 GTF L4546-01 51 K-40 1.40E+03 6.70E+01 8.60E+0I GTF LA546-01 51 La-140 2.20E+00 3.10E+OO I.IOE+01 GTF L4546-01 51 Mn-54 -1.80E+00 1.90E+00 7. 1OE+00 GTF L4546-01 51 Nb-95 -3.OOE+00 1.90E+00 7.40E+00 GTF L4546-01 51 Ru-103 -2.80E+00 1.70E+00 6.40E+00 GTF L4546-01 51 Ru-106 3.OOE+00 1.60E+01 5.60E+01 GTF L4546-01 51 Sb-124 -8.60E+00 4.70E+00 2.OOE+01 GTF L4546-01 51 Sb-125 2.OOE+00 4.1OE+00 1.40E+01 GTF L4546-01 51 Se-75 -7.OOE-01 1.80E+00 6.30E+00 GTF L4546-01 51 Zn-65 -3.30E+00 4.50E+00 1.70E+O1 GTF L4546-01 51' Zr-95 -I.OOE-01 3.IOE+0O I.IOE+01 MR L4546-02 51 AcTh-228 -7.OOE+00 8. 10E+00 2.90E+01 MR L4546-02 51 Ag-108m O.OOE+O0 1.30E+00 4.60E+O0 MR L4546-02 51 Ag- lOim 1.60E+00 2.60E+00 9.10E+00 MR L4546-02 51 Ba-140 1.50E+00 2.90E+00 I.OOE+0I
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-146
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
MR L4546-02 51 Be-7 I.OOE+00 1.30E+01 4.60E+01 MR L4546-02 51 Ce-141 5.30E+00 2.402+00 7.60E+00 MR LA546-02 51 Ce-144 3.00E-01 7.70E+00 2.60E+01 MR L4546-02 51 Co-57 3.OOE-01 1.1OE+00 3.602+00 MR L4546-02 51 Co-58 1.50E+00 1.90E+00 6.50E+O0 MR L4546-02 51 Co-60 -1.90E+00 2.50E+00 9.10E+00 MR L4546-02 51 Cr-51 2.10E+01 1.50E+01 4.90E+01 MR L4546-02 51 Cs-134 4.90E+00 1.90E+00 6.00E+00 MR L4546-02 51 Cs-137 1.80E+00 1.90E+00 6.50E+00 MR L4546-02 51 Fe-59 -9.OOE-01 4.20E+00 1.50E+01 MR L4546-02 51 1-131 1.30E-01 1.20E-01 4.20E-01 MR L4546-02 51 K-40 2.03E+03 7.90E+01 8.50E+0 1 MR L4546-02 51 La-140 1.70E+00 3.30E+00 1.20E+01 MR L4546-02 51 Mn-54 -1.30E+00 1.80E+00 6.80E+00 MR L4546-02 51 Nb-95 -1.20E+00 1.80E+00 6.60E+00 MR L4546-02 51 Ru-103 3.OOE-01 1.80E+00 6.20E+00 MR L4546-02 51 Ru-106 1.70E+01 1.60E+01 5.40E+0l MR L4546-02 51 Sb-124 -7.80E+00 4.10E+00 1.80E+01 MR L4546-02 51 Sb-125 O.OOE+00 4.40E+00 1.50E+01 MR L4546-02 51 Se-75 O.OOE+OO 2.20E+00 7.50E+00 MR L4546-02 51 Zn-65 -I.OOE+00 4.70E+00 1.70E+01 MR L4546-02 51 Zr-95 -9.OOE-01 3.00E+00 1.10E+01 SF L4546-03 51 AcTh-228 l.OOE-01 6.50E+00 2.30E+01 SF L4546-03 51 Ag-108m -1.30E+00 l.OOE+O0 3.80E+00 SF L4546-03 51 Ag-lOrm 1.80E+00 2.OOE+00 6.80E+O0 SF L4546-03 51 Ba-140 -3.OOE-01 2.40E+00 8.90E+00 SF L4546-03 51 Be-7 6.OOE+00 1.30E+01 4.30E+01 SF L4546-03 51 Ce-141 l.OOE-01 1.90E+00 6.60E+00 SF 14546-03 51 Ce-144 6.80E+00 6.40E+00 2.10E+01 SF L4546-03 51 Co-57 -3.30E-01 8.30E-01 2.90E+00 SF L4546-03 51 Co-58 -2.50E+00 1.40E+00 5.20E+00 SF L4546-03 51 Co-60 2.20E+00 1.80E+00 6.OOE+00 SF L4546-03 51 Cr-51 2.80E+01 1.20E+01 3.90E+01 SF L4546-03 51 Cs-134 5.00E-01 1.60E+00 5.60E+00 SF L4546-03 51 Cs-137 7.00E-01 1.40E+00 4.70E+00 SF L4546-03 51 Fe-59 2.20E+00 3.30E+00 1.IOE+01 SF 14546-03 51 1-131 4.00E-01 2.50E-01 6.90E-01 SF 14546 51 K40 1.38E+03 5.40E+01 6.60E+01
- SF L4546-03 51 La-140 -4.00E-01 2.80E+00 1.00E+01 SF L4546-03 51 Mn-54 -1.60E+00 1.402+00 5.20E+00
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-147
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
SF L4546-03 51 Nb-95 -3.60E+O0 1.501E+O0 5.80E+O0 SF L4546-03 51 Ru-103 -1.40E+O0 1.40E+O0 5.20E+00 SF L4546-03 51 Ru-106 4.OOE+O0 1.20E+01 4.20E+OI SF L4546-03 51 Sb-124 2.60E+O0 3.20E+00 l .OE+0O SF L4546-03 51 Sb-125 6. 10E+00 3.40E+O0 1.1OE+0O SF L4546-03 51 Se-75 1.70E+00 1.70E+O0 5.70E+00 SF L4546-03 51 Zn-65 -7.80E+O0 3.50E+00 1.40E+OI SF L4546-03 51 Zr-95 -7.OOE-01 2.40E3+00 8.80E+O0 LP L4546-04 51 Aclb-228 5.50E+O0 5.70E+O0 1.90E3+01 LF L4546-04 51 Ag-108m -6.00E-01 l.IOE+O0 3.90E3+00 LP L4546-04 51 Ag-I lOm -6.00E-01 1.80E+00 6.80E+O0 LF L4546-04 51 Ba-140 4.1OE+00 2. 10E+00 6.70E+O0 LP L4546-04 51 Be-7 -1.80E+O1 l.lOE+O1 4.30E+01 LP L4546-04 51 Ce-141 1.90E+O0 2.00E+O0 6.90E+O0 LF L4546-04 51 Ce-144 5.30E+O0 7.80E+00 2.60E1+O1 LF L4546-04 51 Co-57 l.IOE+00 l.OOE+00 3.40E+00 LF L4546-04 51 Co-58 -1.70E+O0 1.50E+O0 5.60E+00 LF L4546-04 51 Co-60 1.90E+O0 1.90E+O0 6.50E3+00 LF L4546-04 51 Cr-51 -1.20E+O1 1.30E+O1 4.60E+01 LF L4546-04 51 Cs-134 -4.OOE-01 1.501E+00 5.30E+00 LF L4546-04 51 Cs-137 -1.80E+O0 1.40E+O0 5.40E+00 LF L4546-04 51 Fe-59 -7. 10E+O0 3.OOE+00 1.20E+O1 LF L4546-04 51 1-131 -9. 1OE-02 1.90E-02 7.50E-O1 LF L4546-04 51 K-40 1.44E+03 5.90E+0O 7.40E+01 LF L4546-04 51 La-140 4.80E+00 2.40E+O0 7.70E+O0 LP L4546-04 51 Mn-54 -1.70E+3O0 1.40E+O0 5.20E+00 LF L4546-04 51 Nb-95 1.20E+3O0 1.60E+00 5.40E+OO LF L4546-04 51 Ru-103 -7.00E-01 1.501E+O0 5.30E+O0 LF L4546-04 51 Ru-106 -2.OOE+O0 1.30E+0O 4.70E+OI LF L4546-04 51 Sb-124 -2.90E+00 3.40E+OO 1.40E+O1 LF L4546-04 51 Sb-125 l.90E+O0 3.40E+O0 1.20E+01 LF L4546-04 51 Se-75 1.80E+00 1.40E+00 4.80E+00 LF L4546-04 51 Zn-65 6.30E+O0 6.80E+O0 2.30E+01 LF L4546-04 51 Zr-95 1.60E+O0 2.80E+O0 9.70E+O0 WF L4546-05 51 AcTh-228 1.48E+OI 7.00E+O0 2.30E+0O WF L4546-05 51 Ag-108m -8.00E-0O 1.30E+00 4.70E+O0 WF L4546-05 51 Ag-llOm 1.30E+O0 2.40E+00 8.40E3+00 WF L4546-05 51 Ba-140 5.60E1O0 2.60E+00 8.30E+O0 WF L4546-05 51 Be-7 -2.90E+O1 1.30E+0I 5.00E+01 WF L4546-05 51 Ce-141 2.80E+O0 2.70E+O0 9. IOE+00
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D- 148
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
WF L4546-05 51 Ce-144 -1.97E+01 9.90E+00 3.50E+OI WF L4546-05 51 Co-57 -4.OOE-01 1.20E+00 4.20E+OO WF L4546-05 51 Co-58 -6.OOE-01 1.60E+00 5.90E+OO WF L4546-05 51 Co-60 1.30E+00 2.OOE+00 6.80E+OO WF L4546-05 51 Cr-51 2.OOE+00 1.50E+01 5.10E+OI WF L4546-05 51 Cs-134 -5.OOE-01 1.70E+00 6.20E+0O WF L4546-05 51 Cs-137 8.OOE-01 1.60E+00 5.70E+0O WF L4546-05 51 Fe-59 1.50E+00 3.40E+00 1.20E+01 WF L4546-05 51 1-131 -9.30E-02 1.90E-02 6.90E-OI WF L4546-05 51 K-40 1.30E+03 5.70E+01 8.1OE+01 WF L4546-05 51 La-140 6.40E+00 3.OOE+00 9.50E+0O WF L4546-05 51 Mn-54 -8.OOE-01 1.70E+00 6. 1OE+OO WF L4546-05 51 Nb-95 -2.1OE+00 1.90E+00 6.90E+OO WF LA546-05 51 Ru-103 -I.OOE-0O 1.90E+00 6.50E+OO WF L4546-05 51 Ru-106 1.70E+01 1.60E+01 5.40E+0O WF L4546-05 51 Sb-124 1.1OE+0O 4.10E+00 1.50E+OI WF L4546-05 51 Sb-125 -5.40E+00 3.80E+00 1.40E+OI WF L4546-05 51 Se-75 3.OOE-01 2.OOE+00 6.80E+OO WF L4546-05 51 Zn-65 -1.50E+01 4.10E+00 1.70E+0O WF L4546-05 51 Zr-95 I.OOE+0O 2.90E+00 I.OOE+01
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-149
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/lkg) (pCi/kg)
WD STJ L2062-01 02 AcTh-228 1.03E+01 3.90E+00 1.20E+01 STJ L2062-01 02 Ag-108m -6.50E-01 9.30E-01 3.30E+00 STJ L2062-01 02 Ag-1 10m 7.00E-01 1.60E+00 5.40E+00 STJ L2062-01 02 Ba-140 2.60E+00 2.30E+00 7.70E+00 STJ L2062-01 02 Be-7 O.OOE+00 9.20E+00 3.20E+0O STJ L2062-01 02 Ce-141 -1.80E+00 1.80E+00 6.40E+00 STJ L2062-01 02 Ce-144 5.40E+00 5.70E+00 I.90E+01 STJ L2062-01 02 Co-57 3.60E-01 7.40E-01 2.50E+O0 STJ L2062-01 02 Co-58 -4.OOE-0 1.IOE+00 3.80E+00 STJ L2062-01 02 Co-60 -4.OOE-01 1.20E+00 4.30E+00 STJ L2062-01 02 Cr-51 1.20E+0O I.IOE+0O 3.70E+01 STJ L2062-01 02 Cs-134 -I.OOE-01 l.lOE+00 4.OOE+00 STJ L2062-01 02 Cs-137 -2.OOE+00 1.20E+00 4.30E+00 STJ L2062-01 02 Fe-59 3.60E+00 3.30E+00 1.IOE+0O STJ L2062-01 02 GROSS BETA 1.45E+00 6.30E-01 2.OOE+00 STJ L2062-01 02 1-131 7.40E-01 4.10E-01 1.20E+00 STJ L2062-01 02 K-40 -9.OOE+00 1.70E+01 6.20E+0O STJ L2062-01 02 La-140 3.00E+00 2.60E+00 8.80E+00 STJ L2062-01 02 Mn-54 -6.30E-01 9.50E-01 3.50E+00 STJ L2062-01 02 Nb-95 -2. 10E+00 2.OOE+00 7.40E+00 STJ L2062-01 02 Ru-103 -8.00E-0O I.IOE+00 3.80E+00 STJ L2062-01 02 Ru-106 -3.OOE+00 1.OOE+01 3.70E+0O STJ L2062-01 02 Sb-124 -1.60E+00 2.80E+00 I.1OE+01 STJ L2062-01 02 Sb-125 2.60E+00 2.80E+00 9.30E+00 STJ L2062-01 02 Se-75 -1.40E+00 1.IOE+00 4.10E+00 STJ L2062-01 02 Zn-65 5.60E+00 5.70E+00 l.90E+0O STJ L2062-01 02 Zr-95 -1.20E+00 1.90E+00 7.OOE+00 LTW L2062-02 02 AcTh-228 1.32E+01 5.50E+00 2.00E+0I LTW L2062-02 02 Ag-108m -7.00E-01 1.20E+00 4.20E+00 LTW L2062-02 02 Ag-1 10m -2. 10E+00 2.20E+00 8.00E+00 LTW L2062-02 02 Ba-140 I.IOE+00 4.60E+00 1.70E+0O LTW L2062-02 02 Be-7 1.30E1+01 1.60E+01 5.50E+0I LTW L2062-02 02 Ce-141 1.30E+00 3.40E+00 I.1OE+01 LTW L2062-02 02 Ce-144 4.OOE+00 I.OOE+0O 3.50E+0O LTW L2062-02 02 Co-57 1.30E+00 1.20E+00 4.101E+00 LTW L2062-02 02 Co-58 3.OOE+00 1.50E+00 4.90E+00 LTW L2062-02 02 Co-60 -1.70E+00 1.60E+00 6.30E+00 LTW L2062-02 02 Cr-51 2.40E+0O I.90E+01 6.40E+0I LTW L2062-02 02 Cs-134 3.OOE-01 1.60E+00 5.70E+00
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-150
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
LTW L2062-02 02 Cs-137 1.IOE+00 1.60E+00 5.50E+00 LTW L2062-02 02 Fe-59 3.80E+00 5.40E+00 1.90E+01 LTW L2062-02 02 GROSS BETA 3.69E+00 6.60E-01 1.90E+00 LTW L2062-02 02 1-131 6.30E-01 4.00E-01 1.20E+O0 LTW L2062-02 02 K-40 -3.OOE+01 2.20E+01 8.20E+01 LTW L2062-02 02 La-140 1.30E+00 5.30E+00 1.90E+01 LTW- L2062-02 02 Mn-54 -3.40E+00 1.70E+00 6.60E+00 LTW L2062-02 02 Nb-95 -5.OOE+O0 2.10E+00 8.30E+00 LTW L2062-02 02 Ru-103 -1.40E+00 2.10E+00 7.30E+00 LTW L2062-02 02 Ru-106 -2.40E+01 1.40E+01 5.30E+01 LTW L2062-02 02 Sb-124 -3.40E+00 4.40E+00 1.70E+01 LTW L2062-02 02 Sb-125 7.OOE-01 4.OOE+00 1.40E+01 LTW L2062-02 02 Se-75 -6.OOE-01 2.OOE+00 7.OOE+00 LTW L2062-02 02 Zn-65 9.20E+00 6.40E+00 2.10E+01 LTW L2062-02 02 Zr-95 4.60E+00 3.00E+00 9.90E+00 STJ L2121-01 04 AcTh-228 -1.40E+00 2.90E+00 9.60E+00 STJ L2121-01 04 Ag-108m 1.20E-01 3.50E-01 1.20E+00 STJ L2121-01 04 Ag-110m -1.30E-01 5.90E-01 2.OOE+00 STJ L2121-01 04 Ba-140 9.OOE-01 3.20E+00 1.1OE+01 STJ L2121-01 04 Be-7 4.10E+00 4.80E+00 1.60E+01 STJ L2121-01 04 Ce-141 2.OOE+00 1.lOE+00 3.60E+00 STJ L2121-01 04 Ce-144 3.OOE-01 2.40E+00 7.90E+00 STJ L2121-01 04 Co-57 O.OOE+00 3.10E-01 1.OOE+00 STJ L2121-01 04 Co-58 8.OOE-02 4.90E-01 1.70E+00 STJ L2121-01 04 Co-60 4.OOE-01 4.50E-01 1.50E+00 STJ L2121-01 04 Cr-51 -5.20E+00 7.90E+00 2.70E+01 STJ L2121-01 04 Cs-134 8.80E-01 4.10E-01 1.40E+00 STJ L21 21-01 04 Cs-137 -1.04E+00 4.40E-01 1.50E+00 STJ L2121-01 04 Fe-59 O.OOE+00 1.90E+00 6.40E+00 STJ L2121-01 04 GROSS BETA 3.71E+00 6.10E-01 1.70E+00 STJ L2121-01 04 1-131 5.OOE-02 2.30E-01 8.30E-01 STJ L2121 01 04 K-40 -1.OOE-01 9.40E+00 3.10E+01 STJ L2121-01 04 La-140 1.lOE+00 3.60E+00 1.20E+01 STJ L2121-01 04 Mn-54 6.OOE-02 4.40E-01 1.50E+00 STJ L2121-01 04 Nb-95 3.40E-01 7.50E-01 2.50E+00 STJ L2121-01 04 Ru-103 -1.70E+00 6.90E-01 2.40E+00 STJ L2121-01 04 Ru-106 O.OOE+00 4.10E+00 1.40E+01 STJ L2121-01 04 Sb-124 -1.30E+00 1.40E+00 4.90E+00
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-151
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
STJ L2121-01 04 Sb-125 5.00E-01 1.10O+00 3.60E+00 STJ L2121-01 04 Se-75 7.00E-02 6.00E-01 2.00E+00 STJ L2121-01 04 Zn-65 -I.IOE+00 1.20E+00 4.30E+00 STJ L2121-01 04 Zr-9S 3.00E-02 9.10E-01 3.10E+00 LTW L2121-02 04 AcTh-228 -6.00E-01 2.20E+00 7.50+00 LTW L2121-02 04 Ag-108m -2.90E-01 3.40E-01 1.20E+O0 LTW L2121-02 04 Ag-1 10m -1.50E-01 6.00E-01 2.00E+00 LTW L2121-02 04 Ba-140 5.00E+00 3.00E+00 I.OOE+OI LTW L2121-02 04 Be-7 4.90E+00 5.00E+00 1.60E+0O LTW L2121-02 04 Ce-141 4.00E-01 1.70E+00 5.70E+00 LTW L2121-02 04 Ce-144 -4.20E+00 2.50E+00 8.50E+O0 LTW L2121-02 04 Co-57 1.60E-01 3.30E-01 1.IOE+O0 LTW L2121-02 04 Co-58 -1.70E-01 5.60E-01 1.90E+00 LTW L2121-02 04 Co-60 -3.00E-01 4.20E-01 1.50E+00 LTW L2121-02 04 Cr-51 1.40E+00 7.80E+00 2.60E+O1 LTW L2121-02 04 Cs-134 5.00E-02 4.60E-01 1.50E+00 LTW L2121-02 04 Cs-137 -8.30E-01 4.40E-01 1.50E+00 LTW L2121-02 04 Fe-59 2.50E+00 1.702+00 5.50E+00 LTW L2121-02 04 GROSS BETA 4.93E+00 6.30E-01 1.70E+OO LTW L2121-02 04 1-131 7.00E-02 2.10E-01 7.80E-01 LTW L2121-02 04 K-40 1.96E+01 8.30E+00 2.70E+01 LTW L2121-02 04 La-140 5.80E+00 3.50E+O0 1.102+01 LTW L2121-02 04 Mn-54 6.50E-01 4.50E-01 1.50E+00 LTW L2121-02 04 Nb-95 2.00E-01 1.302+00 4.40E+00 LTW L2121-02 04 Ru-103 -1.97E+00 7.20E-01 2.50E+00 LTW L2121-02 04 Ru-106 3.20E+00 4.102+00 1.402+01 LTW L212i-02 04 Sb-124 -1.30E+00 1.502+00 5.10E+00 LTW L2121-02 04 Sb-125 1.10E+00 1.IOE+00 3.60E+00 LTW L2121-02 04 Se-75 -9.10E-01 6.20E-01 2.10E+00 LTW L2121-02 04 Zn-65 1.00-01 3.002+00 9.80E+00 LTW L2121-02 04 Zr-95 -3.90E-01 9.20E-01 3.10E+00 STJ L2179-01 06 AcTh-228 3.80E+00 3.30E+00 1.102+01 STJ L2179-01 06 Ag-108m -2.50E-01 4.802-01 1.602+00 STJ L2179-01 06 Ag-1 10m -6.70E-01 8.50E-01 3.00E+00 STJ L2179-01 06 Ba-140 3.00E+00 2.302+00 7.70E+00 STJ L2179-01 06 Be-7 9.00E-01 6.20E+00 2.10E+OI STJ L2179-01 06 Ce-141 -2.30E+00 1.302+00 4.50E+00 STJ L2179-01 06 Cc-144 1.012+01 3.80E+00 1.202+01
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-152
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
STJ L2179-01 06 Co-57 1.80E-01 4.80E-01 1.60E+00 STJ L2179-01 06 Co-58 -9.OOE-02 6.70E-01 2.30E+00 STJ L2179-01 06 Co-60 -2.10E-01 6.OOE-01 2.10E+00 STJ L2179-01 06 Cr-51 l.OOE-01 8.20E+00 2.70E+0I STJ L2179-01 06 Cs-134 8.OOE-02 6.10E-01 2. 10E+00 STJ L2179-01 06 Cs-137 4.50E-01 6.OOE-01 2.OOE+00 STJ L2179-01 06 Fe-59 1.30E+00 2.OOE+00 6.90E+00 STJ L2179-01 06 GROSS BETA 1.96E+00 6.60E-01 2.OOE+00 STJ L2179-01 06 1-131 l1.OE-01 1.30E-0I 4.50E-01 STJ L2179-01 06 K-40 -1.OOE+00 l .OE+01 3.80E+01 STJ L2179-01 06 La-140 3.40E+00 2.70E+00 8.90E+00 STJ L2179-01 06 Mn-54 4.70E-01 6.50E-01 2.20E+00 STJ L2179-01 06 Nb-95 4.50E-01 8.70E-01 2.90E+00 STJ L2179-01 06 Ru-103 -6.90E-01 8.20E-0I 2.80E+00 STJ L2179-01 06 Ru-106 7.70E+00 5.60E+00 l.90E+01 STJ L2179-01 06 Sb-124 -1.30E+00 1.70E+00 6.OOE+00 STJ L2179-01 06 Sb-125 1.20E+00 1.50E+00 4.90E+00 STJ L2179-01 06 Se-75 8.00E-02 8.20E-01 2.80E+00 STJ L2179-01 06 Zn-65 1.OOE-01 1.90E+00 6.40E+00 STJ L2179-01 06 Zr-95 3.OOE+00 1.20E+00 3.70E+00 LTW L2179-02 06 AcTh-228 9.OOE-01 3.40E+00 l.1OE+01 LTW L2179-02 06 Ag-108m -1.1OE-0 4.90E-01 1.70E+00 LTW L2179-02 06 Ag-I lOm -1.80E-01 8.80E-01 3.OOE+00 LTW L2179-02 06 Ba-140 8.OOE-01 2.40E+00 8.70E+00 LTW L2179-02 06 Be-7 -8.90E+00 5.60E+00 2.OOE+01 LTW L2179-02 06 Ce-141 -4.OOE-01 1.20E+00 3.90E+00 LTW L2179-02 06 Ce-144 -2.70E+00 3.1OE+00 1.OOE+01 LTW L2179-02 06 Co-57 5.30E-01 4.OOE-01 1.30E+00 LTW L2179-02 06 Co-58 6.30E-0O 7.10E-01 2.40E+00 LTW L2179-02 06 Co-60 -3.OOE-01 7.20E-01 2.50E+00 LTW L2179-02 06 Cr-51 -2.OOE-01 7.90E+00 2.70E+01 LTW L2179-02 06 Cs-134 9.60E-0I 6.30E-01 2.10E+00 LTW L2179-02 06 Cs-137 -1. 16E+00 6.40E-0I 2.30E+00 LTW L2179-02 06 Fe-59 I .OOE+00 2.30E+00 8.OOE+00 LTW L2179-02 06 GROSS BETA 2.58E+00 6.90E-01 2.10E+00 LTW L2179-02 06 1-131 1.30E-01 l. IOE-0I 3.70E-01 LTW L2179-02 06 K-40 -1.70E+0O 1.20E+01 4. 1OE+OI LTW L2179-02 06 La-140 -1.20E+00 2.80E+00 1.OOE+01 LTW L2179-02 06 Mn-54 7.20E-01 6.50E-01 2.20E+00 LTW L2179-02 06 Nb-95 -2.20E+00 1.40E+00 4.80E+00
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-153
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
LTW L2179-02 06 Ru-103 -I.OOE+00 1.IOE+00 3.70E+00 LTW L2179-02 06 Ru-106 6.50E+00 6.00E+00 2.00E+0O LTW L2179-02 06 Sb-124 2.30E+00 2.OOE+00 6.70E+00 LTW L2179-02 06 Sb-125 2.80E+00 1.50E+00 5.OOE+00 LTW L2179-02 06 Se-75 1.18E+00 7.60E-01 2.50E+00 LTW L2179-02 06 Zn-65 6.OOE-01 1.80E+00 6.10E+00 LTW L2179-02 06 Zr-95 8.00E-01 1.20E+00 4.OOE+00 STJ L2261-01 08 AcTh-228 1.30E+00 3.OOE+00 I.OOE+0O STJ L2261-01 08 Ag-108m 6.80E-01 7.90E-01 2.70E+00 STJ L2261-01 08 Ag-I lOm -1.40E+00 1.30E+00 4.70E+00 STJ L2261-01 08 Ba-140 4.OOE+00 2.70E+00 8.90E+00 STJ L2261-01 08 Be-7 -5.40E+00 8.50E+00 3.00E+01 STJ L2261-01 08 Ce-141 -2.00E+00 3.00E3+00 I.OOE+O1 STJ L2261-01 08 Ce-144 -1.08E+01 5.60E+00 1.90E+0O STJ L2261-01 08 Co-57 5.30E-01 7.10E-01 2.40E+00 STJ L2261-01 08 Co-58 -4.OOE-01 I.OOE+00 3.70E+00 STJ L2261-01 08 Co-60 1.30E-01 9.30E-01 3.30E+00 STJ L2261-01 08 Cr-51 -2.40E+01 1.20E+01 4.30E+01 STJ L2261-01 08 Cs-134 7.00E-0I 1.lOE+00 3.60E+00 STJ L2261-01 08 Cs-137 -6.70E-01 9.80E-01 3.50E+00 STJ L2261-01 08 Fe-59 -6.00E-01 2.90E3+00 I.OOE+0O STJ L2261-01 08 GROSSBETA 1.62E1+00 9.90E-01 3.20E+00 STJ L2261-01 08 1-131 I.OOE-0O 2.20E-01 8.30E-0O STJ L2261-01 08 K-40 3.00E+00 1.60E+01 5.50E+0I STJ L2261-01 08 La-140 4.60E+00 3.1OE+00 1.OOE+01 STJ L2261-01 08 Mn-54 -8.00E-01 I.OOE+00 3.60E+00 STJ L2261-01 08 Nb-95 2.80E+00 1.30E1+00 4.40E+00 STJ L2261-01 08 Ru-103 -8.00E-01 1.20E1+00 4.20E3+00 STJ L2261-01 08 Ru-106 1.15E+01 9.1OE+00 3.OOE+0O STJ L2261-01 08 Sb-124 -5.20E+00 2.80E+00 I.IOE+01 STJ L2261-01 08 Sb-125 5.OOE+00 2.50E+00 8.30E+00 STJ L2261 -01 08 Se-75 1.20E+00 1.30E+00 4.20E+00 STJ L2261-01 08 Zn-65 8.OOE-01 3.10E+00 I.OOE+01 STJ L2261-01 08 Zr-95 I.OOE-0I 0 1.70E+00 6.00E+00 LTW L2261-02 08 AcTh-228 -5.00E+00 4.20E1+00 1.50E+0O LTW L2261-02 08 Ag-108m 3.90E-01 7.20E-01 2.50E+00 LTW L2261-02 08 Ag-lOnm -1.30E+00 1.30E+00 4.80E+00 LTW L2261-02 08 Ba-140 -1.80E+00 2.30E+00 8.50E+00
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-154
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
LTW L2261 -02 08 Be-7 1.96E+0I 8.40E2+00 2.70E3+01 LTW L2261-02 08 Ce-141 1.30E+00 1.60E+00 5.20E+00 LTW L2261-02 08 Ce-144 -9.OOE-0I 4.80E+00 1.60E+01 LTW L2261-02 08 Co-57 1.02E+00 6.40E-01 2.l0E+00 LTW L2261 -02 08 Co-58 -4.80E-0I 9.601E-01 3.40E+O0 LTW L2261-02 08 Co-60 1.92E+00 9.90E-01 3.20E+00 LTW L2261-02 08 Cr-51 7.OOE+00 1. lOE+01 3.60E+01 LTW L2261 -02 08 Cs-134 5.IOE-01 8.60E-01 3.OOE+00 LTW L2261-02 08 Cs-137 -2.32E+00 9.60E-01 3.60E+00 LTW L2261 -02 08 Fe-59 3.30E3+00 3.OOE+00 9.90E+00 LTW L2261-02 08 GROSS BETA 3.10E+00 l.OOE1+00 3.IOE+00*
LTW L2261-02 08 1-131 3.40E-01 2.40E3-01 8. 10E-01 LTW L2261-02 08 K-40 -1.30E+01 I1.501E+01 5.40E+01 LTW L2261-02 08 La-140 -2.10OE+00 2.60E+00 9.80E+00 LTW L2261 -02 08 Mn-54 -5.10E-01 8.20E-01 3.OOE+00 LTW L2261-02 08 Nb-95 -4.OOE-01 1.20E+00 4.30E+00 LTW L2261-02 08 Ru-103 -2. 10E+00 1.1OE+00 4.OOE+00 LTW L2261-02 08 Ru-106 -1.35E+01 8.80E+00 3.20E+01 LTW L2261-02 08 Sb-124 -3.00E-01 2.30E+00 8.30E+00 LTW L2261-02 08 Sb-125 -2.90E+00 2.20E+00 8.OOE+00 LTW L2261-02 08 Se-75 -4.10E-01 9.901E-01 3A40E+00 LTW L2261-02 08 Zn-65 -8.OOE-01 2.70E+00 9.60E+00 LTW L2261-02 08 Zr-95 1.1OE+00 I1.70E+00 5.701E+00 STJ L2358-01 09 AcTh-228 -I.OOE+00 4.10OE+00 I1.401E+01 STJ L2358-01 09 Ag-108m -8.00E-02 6.20E-01 2.10E+O0 STJ L2358-01 09 Ag-1 10m -1.80E+00 1.1OE+00 4. 10E+00 STJ L2358-01 09 Ba-140 8.OOE-01 2.001E+00 6.901E+00 STJ L2358-01 09 Be-7 5.OOE+00 7.40E+00 2.50E+01 STJ L2358-01 09 Ce-141 -5.90E+00 2.40E+00 8.20E+00 STJ L2358-01 09 Ce-144 -8.90E+00 5.OOE+00 1.70E+01 STJ L2358-01 09 Co-57 6.60E-01 6.40E-01 2.10OE+00 STJ L2358-01 09 Co-58 -1.77E+00 8.20E-01 3.OOE+00 STJ L2358-01 09 Co-60 4.70E-01 8.30E-01 2.801E+00 STJ L2358-01 09 Cr-51 3.50E+00 8.80E-i00 3.001E+01 STJ L2358-0 09 Cs-134 -8.10E-01 8.60E-01 3.OOE+00 STJ L2358-01 09 Cs-137 9.60E-0O 7.60E-01 2.50E+00 STJ L2358-01 09 Fe-59 -1 .90E+00 2.40E+00 8.401E+00 STJ L2358-01 09 GROSS BETA 2.43E+00 7. 1O-01 2.10E+00 *
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-155
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
STJ 12358-01 09 1-131 -5.00E-02 2.00E-01 9.00E-01 STJ L2358-01 09 K-40 5.00E+00 1.40E+01 4.70E+01 STJ L2358-01 09 La-140 9.OOE-0O 2.30E+00 7.902+00 STJ L2358-01 09 Mn-54 5.30E-01 8.20E-01 2.802+00 STJ L2358-01 09 Nb-95 3.50E-01 9.80E-01 3.30E+00 STJ L2358-01 09 Ru-103 -5.30E-0O 9.80E-01 3.40E+00 STJ L2358-01 09 Ru-106 -1.69E+01 7. 1OE+00 2.50E+01 STJ L2358-01 09 Sb-124 2.80E+00 2.20E+00 7.30E+00 STJ L2358-01 09 Sb-125 1.30E+00 1.902+00 6.50E+00 STJ L2358-01 09 Se-75 -2.40E+00 1.00E+00 3.60E+00 STJ L2358-01 09 Zn-65 -3.80E+00 1.70E+00 6.302+00 STJ L2358-01 09 Zr-95 -2.10E+00 1.40E+00 4.90E+00 LTW L2358-02 09 AcTh-228 8.20E+00 3.60E+00 1.202+01 LTW L2358-02 09 Ag-108m -5.20E-01 8.30E-01 2.90E+00 LTW L2358-02 09 Ag-1 10m 9.00E-01 1.30E+00 4.50E+00 LTW L2358-02 09 Ba-140 1.OOE-01 1.80E+00 6.40E+00 LTW L2358-02 09 Be-7 -1.75E+01 7.70E+00 2.90E+01 LTW L2358-02 09 Ce- 141 3.00E-0O 1.402+00 4.90E+00 LTW L2358-02 09 Ce-144 8.00E-01 5.00E+00 1.702+01 LTW L2358-02 09 Co-57 6.80E-01 6.50E-01 2.20E+00 LTW L2358-02 09 Co-58 -5.OOE-02 9.40E-01 3.30E+00 LTW L2358-02 09 Co-60 2.OOE-01 1.00E+00 3.60E+00 LTW L2358-02 09 Cr-51 -7.30E+00 9.70E+00 3.40E+01 LTW L2358-02 09 Cs-134 8.102-01 9.40E-01 3.20E+00 LTW L2358-02 09 Cs- 137 1.50E+00 1.00E+00 3.30E+00 LTW L2358-02 09 Fe-59 2.90E+00 2.90E+00 9.90E+00 LTW L2358-02 09 GROSS BETA 2.29E+00 6.90E-01 2.10E+00 LTW L2358-02 09 1-131 8.502-01 3.50E-01 8.70E-01 LTW L2358-02 09 K-40 8.00E+00 1.60E+01 5.30E+01 LTW L2358-02 09 La-140 1.OOE-01 2.00E+00 7.40E+00 LTW L2358-02 09 Mn-54 -2.34E+00 8.50E-01 3.40E+00 LTW L2358-02 09 Nb-95 -1.90E+00 1.IOE+00 4.20E+00 LTW L2358-02 09 Ru-103 4.00E-01 1.00+00 3.60E+00 LTW L2358-02 09 Ru-106 -1.16E+01 8.90E+00 3.20E+01 LTW L2358-02 09 Sb-124 -3.40E+00 2.402+00 9.50E+00 LTW L2358-02 09 Sb-125 -5.402+00 2.40E+00 8.80E+00 LTW L2358-02 09 Se-75 -1.00E-01 1.00+00 3.50E+00 LTW L2358-02 09 Zn-65 2.30E+00 2.70E+00 8.80E+00 LTW L2358-02 09 Zr-95 2.20E+00 1.80E+00 6.10E+00
- Radioactivity detected In sample (i.e., concentration > 3 X standard deviation)
. -156
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program
_- Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
STJ L2438-01 AcTh-228 1.60E+O1 5.90E+00 1.80E+O1 STJ L2438-01 Ag-108m -1.70E-01 9.50E-01 3.40E+O0 STJ L2438-01 Ag-I lOm -1.50E+00 1.50E+00 5.90E+O0 STJ L2438-01 Ba-140 -3.80E+O0 2.20E+00 9.30E+00 STJ L2438-01 Be-7 -8.30E+00 9.80E+00 3.60E+O1 STJ L2438-01 Ce-141 -4.60E+O0 1.80E+00 6.80E+00 STJ L2438-01 Ce-144 2.90E+O0 6.70E+00 2.30E+O1 STJ L2438-01 Co-57 -4.30E-OI 8.20E-01 2.90E+00 STJ L2438-01 Co-58 -1.80E+00 I.1OE+00 4.40E+O0 STJ L2438-01 Co-60 1.30E+00 1.40E+00 5.OOE+00 STJ L2438-01 Cr-51 4.OOE+00 1.20E+01 4.00E+01 STJ L2438-01 Cs-134 -1 .OOE-0O 1.30E+00 4.70E+00 STJ L2438-01 Cs-137 3.OOE-O1 1.40E+00 4.90E+00 STJ L2438-01 Fe-59 3.60E+00 3.IOE+O0 I.1OE+01 STJ L2438-01 GROSS BETA 3.77E+O0 6.70E-01 I.90E+00 STJ L2438-01 1-131 -I .OOE-01 1.50E-01 8.60E-01 STJ L2438-01 K-40 6.20E+O1 1.50E+01 3.80E+01 STJ L2438-01 La-140 -4.40E+O0 2.50E+00 I.IOE+01 STJ L2438-01 Mn-54 O.OOE+O0 l.1OE+O0 3.80E+00 STJ L2438-01 Nb-95 l .OOE-OI 1.40E+00 5.IOE+O0 STJ L2438-01 Ru-103 -1.70E+00 1.40E+00 5.OOE+O0 STJ L2438-01 Ru-106 3.OOE+00 1.IOE+OI 3.80E+O1 STJ L2438-01 Sb-124 1.50E+O0 3.1OE+O0 1.lOE+OI STJ L2438-01 Sb-125 2.80E+OO 3.1OE+00 1.OOE+O1 STJ L2438-01 Se-75 4.OOE-O1 1.30E+00 4.50E+00 STJ L2438-01 Zn-65 -2.60E+OO 2.60E+0O I.OOE+01 STJ L2438-01 Zr-95 4.20E+00 2.20E+00 7.10E+00 LTW L2438-02 AcTh-228 8.10E+00 6.20E+00 2.10E+0O LTW L2438-02 Ag-108m 3.OOE-01 l.lOE+O0 3.80E+00 LTW L2438-02 Ag-i lOm -1.40E+00 1.70E+00 6.40E+O0 LTW L2438-02 Ba-140 4.OOE-01 2.60E+00 9.40E+00 LTW L2438-02 Be-7 2.OOE+O0 1.OOE+01 3.60E+OI LTW L2438-02 Ce-141 -8.OOE-0O 2. 1OE+00 7.20E+00 LTW L2438-02 Ce-144 -2.OOE+00 7.10E+00 2.50E+01 LTW L2438-02 Co-57 1.20E-O1 9.70E-01 3.30E+00 LTW L2438-02 Co-58 -6.OOE-OI 1.30E+00 4.70E+00 LTW L2438-02 Co-60 5.OOE-O1 1.30E+00 4.80E+OO LTW L2438-02 Cr-51 -2.10E+0O 1.30E+01 4.60E+01
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-157
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
LTW L2438-02 11 Cs-134 5.00E-01 1.20E+00 4.30E+00 LTW L2438-02 11 Cs-137 -1.00O+00 1.20E+00 4.60E+00 LTW L2438-02 11 Fe-59 -7.00E-01 4.20E+00 1.50E+01 LTW L2438-02 11 GROSS BETA 1.88E+00 6.30E-01 I.90E+O0 LTW L2438-02 11 1-131 -1.80E-01 1.30E-01 9.40E-01 LTW L2438-02 11 K-40 -1.30E+01 1.60E+01 5.902+01 LTW L2438-02 11 La-140 5.00E-01 3.00E+00 I.1OE+01 LTW L2438-02 11 Mn-54 4.00E-01 1.30E+00 4.70E+00 LTW L2438-02 11 Nb-95 -3.20E+00 1.60E+00 6. 10E+00 LTW L2438-02 11 Ru-103 4.00E-01 1.30E+00 4.60E+00 LTW L2438-02 11 Ru-106 1.30E+01 1.20E+01 3.90E+01 LTW L2438-02 11 Sb-124 -1.60E+00 3.00E+00 1.20E+01 LTW L2438-02 11 Sb-125 -3.60E+00 3.402+00 1.20E+01 LTW L2438-02 11 Se-75 1.80E+00 1.70E+00 5.80E+00 LTW L2438-02 11 Zn-65 -5.10E+00 3.10E3+00 1.202+01 LTW L2438-02 11 Zr-95 -1.50E+00 2.00E+00 7.60E+00 STJ L2529-01 13 AcTh-228 1.60E+01 5.70E+00 1.80E+01 STJ L2529-01 13 Ag-108m 8.00E-01 1.20E+00 4.10E+00 STJ L2529-01 13 Ag-ll0m -6.OOE-01 2.OOE+00 7.30E+00 STJ L2529-01 13 Ba-140 2.00E+00 3.30E+00 1.20E+01 STJ L2529-01 13 Be-7 -1.40E+01 1.20E+01 4.502+01 STJ L2529-01 13 Ce-141 -2.00E+00 2.80E+00 9.602+00 STJ L2529-01 13 Ce-144 -1.02E+01 9.50E+00 3.30E+01 STJ L2529-01 13 Co-57 3.00E-01 1.20E+00 4.10E+00 STJ L2529-01 13 Co-58 -3.002-01 1.502+00 5.40E+00 STJ L2529-01 13 Co-60 -1.702+00 1.402+00 5.70E+00 STJ L2529-01 13 Cr-51 -2.002+00 1.602+01 5.402+01 STJ L2529-01 13 Cs-134 1.70E+00 1.302+00 4.50E+00 STJ L2529-01 13 Cs-137 -2.00E+00 1.502+00 5.702+00 STJ L2529-01 13 Fe-59 -9.00E+00 3.902+00 1.602+01 STJ L2529-01 13 GROSS BETA 7.51E+00 9.20E-01 2.202+00 STJ L2529-01 13 1-131 1.702-01 2.40E-01 9.602-01 STJ L2529-01 13 K-40 -4.40E+01 2.002+01 7.70E+01 STJ L2529-01 13 La-140 2.302+00 3.802+00 1.302+01 STJ L2529-01 13 Mn-54 -1.002-01 1.40E+00 5.102+00 STJ L2529-01 13 Nb-95 -3.002-01 1.802+00 6.40E+00 STJ L2529-01 13 Ru-103 -3.00E+00 1.80E+00 6.60E+00 STJ L2529-01 13 Ru-106 5.00E+00 1.30E+01 4.602+01
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-158
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
STJ L2529-01 13 Sb-124 5.20E+00 3.70E+00 1.20E+0O STJ L2529-01 13 Sb-125 -8.80E+00 3.80E+00 1.40E+0I STJ L2529-01 13 Se-75 8.OOE-01 I.90E+00 6.30E+00 STJ L2529-01 13 Zn-65 I.IOE+0I 5.70E+0O 1.90E+OI STJ L2529-01 13 Zr-95 -2.40E+00 2.90E+0O 1.OOE+01 LTW L2529-02 13 AcTh-228 -3.90E+00 6.40E+00 2.40E+01 LTW L2529-02 13 Ag-108m 1.50E+00 1.20E+00 4.OOE+00 LTW L2529-02 13 Ag-I Orm 4.OOE+00 2.OOE+00 6.40E+0O LTW L2529-02 13 Ba-140 -6.OOE-01 3.30E+00 1.30E+01 LTW L2529-02 13 Be-7 1.80E+01 1.30E+01 4.20E+01 LTW L2529-02 13 Ce-141 5.OOE-01 2.30E+00 7.80E+00 LTW L2529-02 13 Ce-144 -2.40E+00 7.20E+00 2.50E+01 LTW L2529-02 13 Co-57 2.OOE-02 9.30E-01 3.20E+00 LTW L2529-02 13 Co-58 -2.40E+00 1.50E+00 6.10E+00 LTW L2529-02 13 Co-60 8.OOE-01 1.80E+00 6.30E+0O LTW L2529-02 13 Cr-51 2.60E+01 1.50E+01 4.80E+O1 LTW L2529-02 13 Cs-134 3.OOE-01 1.80E+00 6.30E+00 LTW L2529-02 13 Cs-137 -5.OOE-01 1.60E+00 5.90E+00 LTW L2529-02 13 Fe-59 7.80E+00 4.70E+00 1.50E+01 LTW L2529-02 13 GROSS BETA 4.36E+00 7.90E-01 2.1OE+O0 LTW L2529-02 13 1-131 6.OOE-02 1.40E-01 6.20E-01 LTW L2529-02 13 K-40 -3.OOE+00 I.90E+01 7.20E+0O LTW L2529-02 13 La-140 -7.OOE-01 3.80E+00 1.40E+0O LTW L2529-02 13 Mn-54 7.00E-01 1.60E+00 5.70E+00 LTW L2529-02 13 Nb-95 1.30E+00 1.90E+00 6.70E+00 LTW L2529-02 13 Ru-103 9.OOE-01 1.60E+00 5.40E+00 LTW L2529-02 13 Ru-106 -1.20E+01 1.30E+01 4.90E+01 LTW L2529-02 13 Sb-124 -8.OOE-01 4.80E+00 1.80E+01 LTW L2529-02 13 Sb-125 4.OOE+00 3.70E+00 1.20E+01 LTW L2529-02 13 Se-75 -2.60E+00 I.90E+00 6.70E+00 LTW L2529-02 13 Zn-65 -5.70E+00 3.80E+00 1.50E+0I LTW L2529-02 13 Zr-95 1.70E+00 2.60E+00 8.90E+00 STJ L2683-01 15 AcTh-228 -4.40E+00 5.1OE+00 1.80E+01 STJ L2683-01 15 Ag-108m 3.OOE-0 1.OOE+00 3.50E+0O STJ L2683-01 15 Ag-I Orm -3.10E+00 1.60E+00 6.20E+00 STJ L2683-01 15 Ba-140 -9.OOE-01 3.00E+00 1.IOE+01 STJ L2683-01 15 Be-7 -8.00E+00 I.IOE+0O 3.90E+O1 STJ L2683-01 15 Ce-141 5.OOE-01 2.10E+00 7.OOE+O0
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviatiom)
D-159
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
STJ L2683-01 15 Ce-144 3.00E-01 6.50E+00 2.20E+01 STJ L2683-01 15 Co-57 -2.OOE-02 8.10E-01 2.80E+OO STJ L2683-01 15 Co-S8 -1.OOE+OO 1.20E+00 4.40E+OO STJ L2683-01 15 Co-60 l.90E+00 1.20E+00 4.OOE+00 STJ L2683-01 15 Cr-51 -2.90E+01 1.40E+0I 5.20E+01 STJ L2683-01 15 Cs-134 1.90E+00 1.IOE+O0 3.50E+00 STJ L2683-01 15 Cs-137 -2.10E+00 1.20E+00 4.40E+00 STJ L2683-01 15 Fe-59 7.60E+00 3.90E+00 1.20E+01 STJ L2683-01 15 GROSS BETA 3.30E+00 1.IOE+00 3.10E+00 STJ L2683-01 15 1-131 -2.20E-01 2.20E-01 9.80E-01 STJ L2683-01 15 K-40 1.IOE+01 1.70E+01 5.80E+01 STJ L2683-01 15 La-140 -I.OOE+00 3.50E+00 1.30E+01 STJ L2683-01 15 Mn-54 1.30E+0O 1.I1OE+00 3.70E+00 STJ L2683-01 15 Nb-95 -2.70E+00 1.70E+00 6.40E3+00 STJ L2683-01 15 Ru-103 -1.IOE+00 1.50E1+00 5.20E+0O STJ L2683-01 15 Ru-106 I.OOE+O0 1.IOE+01 4.00E+0O STJ L2683-01 15 Sb-124 -5.40E+00 3.00E+00 1.20E+01 STJ L2683-01 15 Sb-125 0.OOE+00 3.10E+00 1.1OE+01 STJ L2683-01 15 Se-75 0.OOE+00 1.50E+00 5.20E+00 STJ L2683-01 15 Zn-65 -5.00E-01 2.50E+00 9.10E+00 STJ L2683-01 15 Zr-95 1.OOE-O1 2.40E+00 8.30E+00 LTW L2683-02 15 AcTh-228 -3.00E-01 4.70E+00 1.70E+01 LTW L2683-02 15 Ag-108m -3.20E-01 9.10E-01 3.20E+00 LTW L2683-02 15 Ag-i lOm 3.30E+00 1.60E+00 5.00E+00 LTW L2683-02 15 Ba-140 -1.OOE-0O 2.90E+00 1.1OE+0O LTW L2683-02 15 Be-7 -1.08E+01 9.90E+00 3.60E+01 LTW L2683-02 15 Ce-141 1.OOE+00 1.60E+00 5.50E+00 LTW L2683-02 15 Ce-144 1.IOE+00 5.80E+00 2.00E+01 LTW L2683-02 15 Co-57 5.30E-01 7.40E-01 2.50E+00 LTW L2683-02 15 Co-58 -8.OOE-01 1.IOE+00 4.10E+00 LTW L2683-02 15 Co-60 -1.80E+00 I.IOE+O0 4.20E+00 LTW L2683-02 15 Cr-5I -2.60E+01 1.40E+01 5.10E+01 LTW L2683-02 15 Cs-134 -6.00E-01 I.OOE+00 3.80E+00 LTW L2683-02 15 Cs-137 1.OOE-O1 1.20E1+00 4.10E+00 LTW L2683-02 15 Fe-59 7.00E-01 3.40E+00 1.20E+01 LTW L2683-02 15 GROSS BETA 3.00E+00 1.IOE+00 3.30E+00 LTW L2683-02 15 1-131 1.30E-01 2.10E-01 8.10E-01 LTW L2683-02 15 K-40 1.20E+01 1.80E+01 6.10E+01 LTW L2683-02 15 La-140 -I.OOE-0I 3.30E+00 1.20E+01 LTW L2683-02 15 Mn-54 - 1.70E+0O 1.OOE+00 3.90E+00
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-160
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
LTW L2683-02 15 Nb-95 -2.OOE-O1 1.40E+00 4.90E+00 LTW L2683-02 15 Ru-103 -3.40E+00 1.40E+00 5.10E+00 LTW L2683-02 15 Ru-106 2.OOE+00 1.1OE+O1 3.80E+01 LTW L2683-02 15 Sb-124 -1.70E+00 2.90E+O0 1.lOE+01 LTW L2683-02 15 Sb-125 -2.60E+00 2.80E+O0 1.OOE+01 LTW L2683-02 15 Se-75 1.50E+00 1.20E+00 4.10E+00 LTW L2683-02 15 Zn-65 3.OOE+00 2.40E+00 8.OOE+O0 LTW L2683-02 15 Zr-95 2.70E+00 2.30E+00 7.90E+00 STI L2766-01 17 AcTh-228 6.50E+O0 2.80E+00 8.80E+O0 STJ L2766-01 17 Ag-108m -5.20E-01 6.10E-01 2.1OE+00 STJ L2766-01 17 Ag-ll0m 6.OOE-01 I. IOE+00 3.70E+O0 STr L2766-01 17 Ba-140 1.40E+00 2.20E+00 7.70E+O0 STJ L2766-01 17 Be-7 -2.OOE+OO 7.20E+00 2.50E+01 STI L2766-01 17 Ce-141 -5.OOE-01 1.80E+00 6.10E+00 STJ L2766-01 17 Ce-144 -6.20E+00 3.90E+00 1.40E+01 STJ L2766-01 17 Co-57 -2.20E-01 7.10E-01 2.40E+00 STJ L2766-01 17 Co-58 4.40E-01 7.60E-01 2.60E+00 STJ L2766-01 17 Co-60 -2.00E-02 8.10E-01 2.90E+00 STJ L2766-01 17 Cr-51 -8.40E+O0 9.OOE+00 3.1OE+01 STJ L2766-01 17 Cs-134 -7.40E-01 7.60E-01 2.70E+0O STJ L2766-01 17 Cs-137 5.OOE-02 7.60E-01 2.60E+00 STJ L2766-01 17 Fe-59 3.50E+00 2.60E+00 8.60E+00 STJ L2766-01 17 GROSS BETA 2.33E+0O 4.80E-01 1.40E+00
- STJ L2766-01 17 1-131 2.80E-01 2.30E-01 7.70E-O1 STJ L2766-01 17 K-40 9.OOE+00 1.50E+01 5.OOE+01 sT3 L2766-01 17 La-140 1.70E+0O 2.60E+00 8.80E+0O STJ U2766-01 17 Mn-54 -8.90E-01 7.OOE-01 2.50E+00 STJ L2766-01 17 Nb-95 -2.30E-01 9.90E-01 3.50E+00 STJ L2766 17 Ru-103 -1.36E+0O 9.30E-01 3.30E+O0 STJ L2766-01 17 Ru-106 -9.OOE-O1 7.60E+00 2.60E+01 STJ L2766-01 17 Sb-124 1.70E+00 2.20E+00 7.50E+O0 STJ L2766-01 17 Sb-125 -2.70E+0O 1.90E+00 6.70E+O0 STJ L2766-01 17 Se-75 -1.60E+00 8.30E-01 3.OOE+O0 STI L2766-01 17 Zn-65 -1.90E+00 2.10E+00 7.60E+00 STJ L2766-01 17 Zr-95 -3.OOE-O1 1.50E+00 5.20E+00 LTW L2766-02 17 AcTh-228 -2.00E-O1 5.30E+00 1.90E+01 LTW L2766-02 17 Ag-108m -2.30E+0O 9.10E-01 3.50E+0O LTW L2766-02 17 Ag-llbm 8.OOE-O1 1.40E+00 5.OOE+0O
- Radioactivity detected in sample (ie., concentration > 3 X standard deviation)
D-161
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
LTW L2766-02 17 Ba-140 5.10E+00 3.30E+00 I.IOE+01 LTW L2766-02 17 Be-7 -2.60E+0I I.1OE+01 4.20E+01 LTW L2766-02 17 Ce-141 1.60E+00 2.40E+00 8.00E+00 LTW L2766-02 17 Ce-144 2.40E+00 6.20E+00 2.10E+0l LTW L2766-02 17 Co-57 -1.41E+00 9.20E-01 3.30E+00 LTW L2766-02 17 Co-58 -2.20E+00 1.20E+00 4.60E+00 LTW L2766-02 17 Co-60 1.lOE+00 1.30E+00 4.60E+00 LTW L2766-02 17 Cr-SI 4.OOE+00 1.50E+01 5.00E+0O LTW L2766-02 17 Cs-134 6.OOE-OI I.IOE+00 3.90E+0O LTW L2766-02 17 Cs-137 0.OOE+00 1.20E+00 4.40E+00 LTW L2766-02 17 Fe-59 5.OOE-01 3.70E+00 1.30E+0I LTW L2766-02 17 GROSS BETA 1.95E+00 4.80E-01 1.50E+00 LTW L2766-02 17 1-131 3.20E-01 2.80E-0l l.OOE+00 LTW L2766-02 17 K-40 -3.00E+00 I.90E+01 6.60E+01 LTW L2766-02 17 La-140 5.80E+00 3.80E+00 1.30E+0I LTW L2766-02 17 Mn-54 -1.20E+00 1.IOE+00 4.20E+00 LTW L2766-02 17 Nb-95 1.OOE+00 1.60E+00 5.40E+00 LTW L2766-02 17 Ru-103 7.OOE-01 1.40E+00 4.80E+00 LTW L2766-02 17 Ru-106 -7.OOE+00 1.20E+01 4.1OE+OI LTW L2766-02 17 Sb-124 5.00E-01 3.00E+00 1.1OE+0I LTW L2766-02 17 Sb-125 4.60E+00 3.OOE+00 I.OOE+01 LTW L2766-02 17 Se-75 -3.OOE-01 1.30E+00 4.70E+00 LTW L2766-02 17 Zn-65 -3.00E+00 2.60E+00 1.OOE+01 LTW L2766-02 17 Zr-95 -3.00E-01 2.20E+00 7.80E+00 STJ L2860-01 19 AcTh-228 -4.70E+00 4.70E+00 1.70E+0O STJ L2860-01 19 Ag-108m 1.03E+00 8.20E-01 2.70E+00 STJ L2860-01 19 Ag-lOnm O.OOE+00 1.50E+00 5.40E+00 STJ L2860-01 19 Ba-140 -7.00E-01 2.1OE+00 8.10E+00 STJ L2860-01 19 Be-7 7.20E+00 9.OOE+00 3.10E+I01 STJ L2860-01 19 Ce-141 0.OOE+00 1.60E+00 5.60E+00 STJ L2860-01 19 Ce-144 5.20E+00 5.70E+00 1.90E+0I STJ L2860-01 19 Co-57 5.70E-01 8.30E-01 2.80E+00 STJ L2860-01 19 Co-58 2.IOE+00 1.IOE+00 3.50E+00 STJ L2860-01 19 Co-60 -1.50E+00 I.IOE+00 4.40E+00 STJ L2860-01 19 Cr-51 -2.OOE+00 1.IOE+0I 3.90E+01 STJ L2860-01 19 Cs-134 -1.20E+00 I.OOE+00 3.90E+00 STJ L2860-01 19 Cs-137 -I.IOE+00 1.IOE+00 4.10E+00 STJ L2860-01 19 Fe-59 1.20E+00 3.40E1+00 1.20E+0O
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-162
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
STJ L2860-01 19 GROSS BETA 2.30E+00 5.60E-01 1.70E+00 STJ L2860-01 19 1-131 3.OOE-02 2.40E-01 9.30E-0O STJ L2860-01 19 K-40 -4.OOE+00 1.60E+0O 5.80E+01 STJ L2860-01 19 Ln-140 -8.00E-01 2.50E+00 9.30E+00 STJ L2860-01 19 Mn-54 -1.38E+00 9.40E-01 3.60E+00 STJ L2860-01 19 Nb-95 -I.IOE+O0 1.20E+00 4.50E+00 STJ L2860-01 19 Ru-103 I.OOE+00 1.20E+00 4.00E+00 STJ L2860-01 19 Ru-106 1.OOE+00 1.OOE+01 3.60E+01 STJ L2860-01 19 Sb-124 1.60E+00 2.70E+00 9.50E+00 STJ L2860-01 19 Sb-125 2.OOE+00 2.60E+00 8.90E+00 STJ L2860-01 19 Se-75 -2.80E+00 I.IOE+00 4.10E+00 STJ L2860-01 19 Znb5 -7.OOE-01 2.10E+00 7.80E+00 STJ L2860-01 19 Zr-95 3.OOE+00 1.90E+00 6.30E+00 LTW L2860-02 19 AcTh-228 -3.00E+00 4.00E+00 1.50E+01 LTW L2860-02 19 Ag-108m 8.80E-01 9.30E-01 3.10E+00 LTW L2860-02 19 Ag-110m -8.OOE-01 1.60E+00 5.70E+00 LTW L2860-02 19 Ba-140 O.OOE+00 2.30E+00 8.30E+00 LTW L2860-02 19 Be-7 -5.30E+00 9.80E+00 3.50E+0O LTW L2860-02 19 Ce-141 -8.30E+00 3.20E+00 1.20E+0O LTW L2860-02 19 Ce-144 -2.10E+00 6.50E+00 2.20E+0O LTW L2860-02 19 Co-57 -8.OOE-01 8.10E-01 2.80E+00 LTW L2860-02 19 Co-58 -2.00E-01 1I.1OE+00 4.OOE+00 LTW L2860-02 19 Co-60 1.OOE+00 1.IOE+00 3.70E+00 LTW L2860-02 19 Cr-51 -6.OOE+00 1.30E+01 4.40E+01 LTW L2860-02 19 Cs-134 7.OOE-01 1.20E+00 4.20E+00 LTW L2860-02 19 Cs-137 -1.OOE-0 1.20E+00 4.20E+00 LTW L2860-02 19 Fe-59 3.40E+00 3.30E+00 I.IOE+01 LTW L2860-02 19 GROSS BETA 2.51E+00 5.80E-01 1.70E+00 LTW L2860-02 19 1-131 -1.90E-01 2.30E-01 9.OOE-01 LTW L2860-02 19 K-40 2.70E+01 2.OOE+01 6.50E+0O LTW L2860-02 19 La-140 Q.OOE+00 2.60E+00 9.60E+00 LTW L2860-02 19 Mn-54 1.IOE+00 1.IOE+00 3.80E+00 LTW L2860-02 19 Nb-95 1.60E+00 1.40E+00 4.60E+00 LTW L2860-02 19 Ru-103 -4.OOE-01 1.20E+00 4.30E+00 LTW L2860-02 19 Ru-106 -8.00E+00 1.IOE+01 3.80E+0O LTW L2860-02 19 Sb-124 -4.00E-01 2.70E+00 1.OOE+01 LTW L2860-02 19 Sb-125 4.OOE+00 2.90E+00 9.80E+00 LTW L2860-02 19 Se-75 4.00E-01 1.50E+00 5.00E+00 LTW L2860-02 19 Zn-65 -2.80E+00 2.60E+00 9.60E+00 LTW L2860-02 19 Zr-95 3.OOE+00 2.OOE+00 6.50E+00
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-163
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program
.Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCilkg)
STJ L2974-01 21 AcTh-228 5.70E+00 2.60E+00 8.50E+00 STJ L2974-01 21 Ag-108m -3.60E-01 5.80E-01 2.00E+00 STJ L2974-01 21 Ag-l lOm 4.00E-01 1.IOE+00 3.60E+00 STJ L2974-01 21 Ba-140 -3.00E+00 2.30E+00 8.40E+00 STJ L2974-01 21 Be-7 -1.40E+00 7. IOE+00 2.40E+01 STJ L2974-01 21 Ce-141 3.80E+00 1.40E+00 4.50E+00 STJ L2974-01 21 Ce-1 44 -2.50E+00 4.10E+00 1.402+01 STJ L2974-01 21 Co-57 3.30E-01 5.30E-01 1.80E+00 STJ L2974-01 21 Co-58 -3.60E-01 8.OOE-01 2.80E+00 STJ L2974-01 21 Co-60 3.60E-01 8.20E-01 2.80E+00 STJ L2974-01 21 Cr-51 -7.80E+00 9. 1OE+00 3.10E+01 STJ L2974-01 21 Cs-134 1.00E+00 7;40E-01 2.50E+00 STJ L2974-01 21 Cs-137 -5.OOE-01 7.10E-01 2.50E+00 STJ L2974-01 21 Fe-59 -1.90E+00 2.40E+00 8.70E+00 STJ L2974-01 21 GROSS BETA 2.75E+00 6.00E-01 1.80E+00 STJ L2974-01 21 1-131 -1.30E-01 2.00E-01 9.20E-01 STJ L2974-01 21 K-40 1.40E+01 1.30E+0O 4.30E+01 STJ L2974-01 21 La-140 -3.50E+00 2.60E+00 9.602+00 STJ L2974-01 21 Mn-54 -4.00E-02 7.30E-01 2.50E+00 STJ L2974-01 21 Nb-95 0.00E+00 1.00E+00 3.50E+00 STJ L2974-01 21 Ru-103 -1.80E-01 9.70E-01 3.30E+00 STJ L2974-01 21 Ru-106 4.80E+00 6.60E+00 2.20E+OI STJ L2974-01 21 Sb- 124 -7.OOE-01 1.90E+00 6.90E+00 STJ L2974-01 21 Sb-125 -1.00E-01 1.90E+00 6.50E+00 STJ L2974-01 21 Se-75 -1. 14E+00 9.70E-01 3.302+00 STJ L2974-01 21 Zn-65 -4.1 OE+00 1.902+00 7.10E+00 STJ L2974-01 21 Zr-95 -2.90E+00 1.30E+00 4.90E+00 LTW L2974-02 21 AcTh-228 6.80E+00 4.10E+00 1.30E+01 LTW L2974-02 21 Ag-108m 3.40E-01 8.30E-01 2.80E+00 LTW L2974-02 21 Ag-I lOm 7.OOE-01 1.50E+00 5.30E+00 LTW L2974-02 21 Ba-140 4.00E-01 3.40E+00 1.20E+01 LTW L2974-02 21 Be-7 3.60E+00 9.00E+00 3. 10E+01 LTW L2974-02 21 Ce-141 1.60E+00 2.40E+00 7.80E+00 LTW L2974-02 21 Ce- 144 -1 .OOE+00 5. 10E+00 1.70E+01 LTW L2974-02 21 Co-57 -7.90E-01 6.30E-01 2.20E+00 LTW L2974-02 21 Co-58 l .OOE+00 1.00E+00 3.50E+00 LTW L2974-02 21 Co-60 8.OOE-01 1.20E+00 4.00E+00 LTW L2974-02 21 Cr-51 1.20E+01 l .10E+01 3.70E+01
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-164
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
LTW L2974-02 21 Cs-134 -1.50E+00 I.OOE+00 3.80E+O0 LTW L2974-02 21 Cs-137 -4.OOE-0 I.1OE+O0 4.OOE+00 LTW L2974-02 21 Fe-59 -1.80E+00 3.90E+00 1.40E+0O LTW L2974-02 21 GROSS BETA 3.10E+00 6.20E-01 1.80E+00 LTW L2974-02 21 1-131 3.OOE-01 2.40E-01 8.20E-01 LTW L2974-02 21 K-40 -8.OOE+00 1.80E+01 6.40E+O1 LTW L2974-02 21 La-140 5.OOE-01 3.90E+00 1.40E+O1 LTW L2974-02 21 Mn-54 -I.OOE-0 1.1OE+00 3.90E+00 LTW L2974-02 21 Nb-95 -3.40E+00 1.70E+00 6.30E+00 LTW L2974-02 21 Ru-103 6.OOE-01 1.30E+00 4.30E+00 LTW L2974-02 21 Ru-106 -2.17E+01 9.50E+00 3.50E+0O LTW L2974-02 21 Sb-124 -3.50E+00 3.30E+00 1.30E+01 LTW L2974-02 21 Sb-125 -1.50E+00 2.60E+00 9.10E+0O LTW L2974-02 21 Se-75 2.20E+00 1.20E+00 3.90E+00 LTW L2974-02 21 Zn-65 -1.30E+00 3.20E+00 1.20E+01 LTW L2974-02 21 Zr-95 l.OOE+O0 1.90E+00 6.60E+00 STJ L3113-01 23 AcTh-228 -5.OOE-01 2.40E+00 9.70E+00 STJ U3113-01 23 Ag-108m 2.OOE-01 5.30E-01 1.80E+00 STJ L3113-01 23 Ag-llOm 8.60E-01 8.70E-01 2.90E+00 STJ 13113-01 23 Ba-140 -8.OOE-01 1.80E+00 6.30E+00 STJ L3113-01 23 Be-7 1.37E+01 6.10E+00 2.OOE+0O STJ 12113-01 23 Ce-141 -2.60E+00 2.10E+00 7.10E+00 STJ 12113-01 23 Ce-144 3.1OE+00 3.90E+00 1.30E+Ol STJ L3113-01 23 Co-57 3.80E-01 5.OOE-01 1.70E+00 STJ 12113-01 23 Co-58 -1.27E+00 7.70E-01 2.70E+00 STJ L3113-01 23 Co-60 -4.OOE-01 6.60E-01 2.40E+0O STJ L3113-01 23 Cr-51 -9.30E+00 7.80E+00 2.70E+0O STJ U3113-01 23 Cs-134 1. IIE+00 7.20E-01 2.40E+OO STJ L3113-01 23 Cs-137 -2.39E+00 7.00E-01 2.60E+OO STJ L3113-01 23 Fe-59 4.30E+00 2.OOE+00 6.50E+00 STJ L3113-01 23 GROSS BETA 4.56E+00 7.70E-01 2.OOE+OO STJ L3113-01 23 1-131 2.30E-01 2.70E-01 9.90E-OI STJ L3113-01 23 K40 1.70E+01 1.20E+01 3.80E+0O STJ L3113-01 23 La-140 -I.OOE+00 2.00E-+00 7.20E+00 STJ L3113-01 23 Mn-54 1.70E-01 6.70E-01 2.30E+00 STJ U3113-01 23 Nb-95 3.OOE-01 1.20E+00 4.OOE+00 STJ 12113-01 23 Ru-103 -1.38E+00 7.90E-01 2.80E+00 STJ 13113-01 23 Ru-106 2.50E+00 6.OOE+00 2.OOE+0O
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-165
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
STJ L3113-01 23 Sb-124 -I.SOE+00 1.80E+00 6.60E+00 STJ L3113-01 23 Sb-125 9.00E-01 1.70E+00 5.70E+O0 STJI L3113-01 23 Sc-75 -1.57E+00 8.70E-01 3.OOE+00 STJ L3113-01 23 Zn-65 -4.80E+00 2.20E+00 8.1OE+00 STJ L3113-01 23 Zr-95 1.20E+00 1.20E+00 4.1OE+O0 LTW L3113-02 23 AcTh-228 -2.80E+00 3.70E+00 1.30E+0O LTW L3113-02 23 Ag-108m 7.70E-01 5.30E-01 1.70E+O0 LTW L3113-02 23 Ag-llOm -7.70E-01 8.50E-01 3.OOE+O0 LTW L3113-02 23 Ba-140 -1.40E+00 1.70E+00 6.00E+00 LTW L3113-02 23 Be-7 9.70E+00 5.70E+O0 I.90E+01 LTW L3113-02 23 Ce-141 -2.80E+00 1.70E+00 6.OOE+O0 LTW U2113-02 23 Ce-144 3.1OE+00 3.30E+00 1.IOE+01 LTW L3113-02 23 Co-57 4.00E-02 4.101E-01 1.40E+0O LTW L3113-02 23 Co-58 2.90E-01 6.30E-01 2.1OE+00 LTW L3113-02 23 Co-60 -1.32E+00 6.40E-01 2.40E+O0 LTW L3113-02 23 Cr-51 -I.OIE+01 7.10E+00 2.50E+0O LTW L3113-02 23 Cs-134 1.60E-01 6.30E-01 2.20E+00 LTW L3113-02 23 Cs-137 -4.40E-01 6.30E-01 2.20E+00 LTW L3113-02 23 Fe-59 -2.60E+00 1.50E+00 5.40E+00 LTW L3113-02 23 GROSS BETA 2.82E+00 7.40E-01 2.20E+00 LTW L3113-02 23 1-131 2.OOE-02 2.10E-01 9.1OE-01 LTW L3113-02 23 K-40 5.OOE+00 1.20E+01 4.10E+01 LTW L3113-02 23 La-140 -1.60E+00 1.90E+00 6.90E+00 LTW L3113-02 23 Mn-54 -1.09E+00 5.70E-01 2.10E+00 LTW L3113-02 23 Nb-95 2.90E+00 1.20E+00 3.90E+00 LTW L3113-02 23 Ru-103 -2.52E+00 7.40E-01 2.70E+00 LTW 12113-02 23 Ru-106 -2.60E+00 5.90E+00 2.00E+0O LTW L3113-02 23 Sb-124 -6.20E+00 2.40E+00 9.30E+00 LTW W3113-02 23 Sb-125 -5.00E-01 1.50E+00 5.20E+00 LTW L3113-02 23 Se-75 -1.29E+00 6.60E-01 2.30E+00 LTW L3113-02 23 Zn-65 -8.00E-01 1.80E+00 6.30E+00 LTW L3113-02 23 Zr-95 2.00E-01 1.20E+00 4.OOE+00 STJ L3207-01 25 AcTh-228 4.00E-01 3.OOE+00 1.IOE+01 STJ L3207-01 25 Ag-108m -4.40E-01 7.30E-01 2.70E+00 STJ L3207-01 25 Ag-I lOm 1.60E-01 9.70E-01 3.60E+00 STJ L3207-01 25 Ba-140 -I.OOE+00 2.70E+00 I.OOE+01 STJ W3207-01 25 Be-7 -2.70E+00 9.OOE+00 3.20E+01 STJ 12207-01 25 Ce-141 -3.OOE+00 2.10E+00 7.50E+00 Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-166
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
STJ L3207-01 25 Cc-144 -3.OOE+00 5.60E+00 2.OOE+O1 STJ L3207-01 25 Co-57 -6.80E-01 7.SOE-01 2.70E+00 STJ L3207-01 25 Co-58 -6.20E-01 9.OOE-01 3.40E+00 STJ L3207-01 25 Co-60 -6.70E-01 7.40E-01 3.OOE+00 STJ L3207-01 25 Cr-51 I.OOE+00 1.20E+01 4.20E+01 STJ L3207-01 25 Cs-134 -1.40E-01 7.30E-01 2.80E+00 STJ L3207-01 25 Cs-137 2.80E-01 8.60E-01 3.10E+00 STJ L3207-01 25 Fe-59 3.10E+00 2.60E+00 9.OOE+00 STJ L3207-01 25 GROSS BETA 5.42E+00 9.90E-01 2.60E+00 STJ L3207-01 25 1-131 -2.OOE-01 1.40E-01 6.20E-01 STJ L3207-01 25 K-40 4.OOE+00 1.20E+01 4.10E+01 STJ L3207-01 25 La-140 -1.20E+00 3.10E+00 1.20E+0O STJ L3207-01 25 Mn-54 1.31E+00 7.40E-01 2.40E+00 STJ L3207-01 25 Nb-95 -1.90E+00 1.20E+00 4.70E+00 STJ L3207-01 25 Ru-103 -6.OOE-0 1.IOE+00 4.OOE+00 STJ U3207-01 25 Ru-106 9.80E+00 7.80E+00 2.60E+01 STJ L3207-01 25 Sb-124 -3.60E+00 2.70E+00 I.IOE+01 STJ L3207-01 25 Sb-125 -1.40E+00 2.30E+00 1.60E+01 STJ L3207-01 25 Se-75 5.OOE-01 1.20E+00 4.20E+00 STJ L3207-01 25 Zn-65 -2.90E+00 1.60E+00 6.70E+00 STJ L3207-01 25 Zr-95 1.90E+00 1.40E+00 4.80E+00 LTW L3207-02 25 AcTh-228 3.30E+00 2.SOE+00 8.40E+OO LTW L3207-02 25 Ag-108m O.OOE+00 6.70E-01 2.40E+OO LTW L3207-02 25 Ag-lOrm I.OOE-0 l.OOE+00 3.70E+OO LTW L3207-02 25 Ba-140 1.OOE-01 2.10E+00 8.20E+OO LTW L3207-02 25 Be-7 -5.90E+00 8.20E+00 3.00E+01 LTW L3207-02 25 Ce-141 -5.OOE-01 1.8OE+00 6.40E+OO LTW L3207-02 25 Ce-144 3.40E+00 5.40E+00 1.80E+0O LTW L3207-02 25 Co-57 2.50E-01 6.70E-01 2.30E+00 LTW L3207-02 25 Co-58 9.20E-01 7.80E-01 2.70E+00 LTW L3207-02 25 Co-60 1.19E+00 7.40E-01 2.40E+00 LTW L3207-02 25 Cr-51 -7.OOE+00 1.IOE+OI 3.80E+01 LTW L3207-02 25 Cs-134 5.80E-01 7.70E-01 2.70E+00 LTW L3207-02 25 Cs-137 -4.50E-01 7.80E-01 2.90E+00 LTW L3207-02 25 Fe-59 -2.60E+00 2.50E+00 I.OOE+01 LTW L3207-02 25 GROSS BETA 6.80E+00 I.OOE+00 2.40E+00 LTW L3207-02 25 1-131 3.OOE-02 1.90E-01 7.90E-01 LTW L3207-02 25 K-40 1.IOE+OI 1.1OE+01 3.70E+01 LTW L3207-02 25 La-140 I.OOE-01 2.40E+00 9.50E+00 LTW L3207-02 25 Mn-54 -1.OIE+00 7.50E-01 3.OOE+00
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-167
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
LTW L3207-02 25 Nb-95 1.90E-01 9.60E-01 3.50E+00 LTW L3207-02 25 Ru-103 -2.60E+00 1.IOE+00 4.40E+00 LTW L3207-02 25' Ru-106 4.20E+00 7.50E+00 2.60E+01 LTW L3207-02 25 Sb-124 -2.103E+00 2.20E+00 9.102+00 LTW L3207-02 25 Sb-125 0.00+00 2.102+00 7.50E+00 LTW L3207-02 25 Se-75 1.87E+00 9.80E-01 3.202+00 LTW L3207-02 25 Zn-65 -5.OOE-01 1.70E+00 6.30E+00 LTW L3207-02 25 Zr-95 1.40E+00 1.50E+00 5.30E+00 STJ L3289-01 27 AcTh-228 -6.20E+00 5.40E+00 2.00E+01 STJ L3289-01 27 Ag-108m 6.00E-01 1.1OE+00 3.80E+00 STJ L3289-01 27 Ag-l lOm -1.00E+00 1.70E+00 6.30E+00 STJ L3289-01 27 Ba- 140 -1.80E+00 3.20E+00 1.20E+01 STJ L3289-01 27 Be-7 -2.10E+01 1.102+01 4.20E+01 STJ L3289-01 27 Ce-141 2.00E+00 2.20E+00 7.30E+00 STJ L3289-01 27 Ce-144 1.82E+01 7.30E+00 2.30E+01 STJ L3289-01 27 Co-57 8.30E-01 9.302-01 3.102+00 STJ L3289-01 27 Co-58 -2.30E+00 1.30E+00 5.00E+00 STJ L3289-01 27 Co-60 -1.40E+00 1.40E+00 5.50E+00 STJ L3289-01 27 Cr-51 3.40E+01 1.40E+01 4.402+01 STJ L3289-01 27 Cs-134 O.OOE+00 1.40E+00 4.90E+00 STJ L3289-01 27 Cs-137 -3.20E+00 1.30E+00 5.30E+00 STJ 12289-01 27 Fe-59 5.10+00 4.00E+00 1.40E+01 STJ L3289-01 27 GROSS BETA 5.311E+00 9.80E-01 2.50E+00 STJ L3289-01 27 1-131 2.70E-01 2.60E-01 9.40E-01 STJ L3289-01 27 K-40 4.20E+01 2.00E+01 6.50E+01 STJ L3289-01 27 La-140 -2.00E+00 3.70E+00 1.40E+01 STJ L3289-01 27 Mn-54 2.90E+00 1.40E+00 4.60E+00 STJ L3289-01 27 Nb-95 -2.50E+00 1.60E+00 6.00E+00 STJ L3289-01 27 Ru-103 -1.30E+00 1.50E+00 5.60E+00 STJ L3289-01 27 Ru-106 -1.10E+01 1.lOE+01 4.10E+01 STJ L3289-01 27 Sb-124 5.00E-01 3.40E+00 1.20E+01 STJ L3289-01 27 Sb-125 -4.90E+00 3.50E+00 1.30E+01 STJ L3289-01 27 Se-75 -1.20E+00 1.80E+00 6.20E+00 STJ L3289-01 27 Zn-65 -1.25E+01 3.70E+00 1.502+01 STJ L3289-01 27 Zr-95 -3.00E-01 2.10E+00 7.50E+00 LTW L3289-02 27 AcTh-228 4.40E+00 5.20E+00 1.80E+01 LTW L3289-02 27 Ag-108m 0.00+00 1.20E+00 4.20E+00 LTW L3289-02 27 Ag-Il Om -1.60E+00 1.90E+00 6.90E+00
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-168
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
LTW U3289-02 27 Ba-140 -4.00E-01 2.80E+00 1.OOE+01 LTW U3289-02 27 Be-7 -1.OOE+00 1.20E+01 4.30E+01 LTW U3289-02 27 Ce-141 -7.002-01 1.90E+00 6.50E+00 LTW U3289-02 27 Ce-144 -3. 10E+00 7.60E+00 2.60E+01 LTW L3289-02 27 Co-57 1.72E+00 9.50E-01 3.10E+00 LTW U3289-02 27 Co-58 6.00E-01 1.50E+00 5. IOE+00 LTW U3289-02 27 Co-60 I.00-01 1.30E+00 4.70E+00 LTW U3289-02 27 Cr-51 1.40E+01 1.30E+01 4.50E+01 LTW 12289-02 27 Cs-134 1.90E+00 1.50E+00 5.20E+00 LTW U3289-02 27 Cs-137 -5.OOE-01 1.50E+00 5.30E+00 LTW 12289-02 27 Fe-59 -7.90E+00 3.30E+00 1.40E+01 LTW U3289-02 27 GROSS BETA 3.92E+00 9.40E-01 2.60E+00 LTW U3289-02 27 1-131 -7.00E-02 1.80E-01 9.90E-01 LTW U3289-02 27 K-40 1.00E+00 1.90E+01 6.80E+01 LTW U3289-02 27 La-140 -5.00E-01 3.20E+00 1.20E+0I LTW U3289-02 27 Mn-54 l .OOE-01 1.20E+00 4.40E+00 LTW U3289-02 27 Nb-95 -2.00E-01 1.60E+00 5.90E+00 LTW U3289-02 27 Ru-103 2.20E+00 1.40E+00 4.50E+00 LTW U3289-02 27 Ru-106 1.10E+01 1.20E+01 4.00E+01 LTW U3289-02 27 Sb-124 -2.00E-OI 3.OOE+00 1.20E+01 LTW U3289-02 27 Sb-125 -1.1OE+00 3.50E+00 1.202+01 LTW U3289-02 27 Se-75 2.50E+00 1.80E+00 5.80E+00 LTW U3289-02 27 Zn-65 4.20E+00 5. 1OE+00 1.70E+01 LTW U3289-02 27 Zr-95 3. 1OE+00 2.60E+00 8.80E+00 STJ L3396-01 30 AcTh-228 4.50E3+00 3.20E+00 1.10E+01 STJ L3396-01 30 Ag-108m 9.00E-02 4.60E-01 1.60E+00 STJ L3396-01 30 Ag-i Orm 1.28E+00 7.90E-0I 2.60E+00 STJ L3396-01 30 Ba-140 3.20E+00 2.50E+00 8.50E+00 STJ L3396-01 30 Be-7 -5.70E+00 5.60E+00 1.90E+01 STJ L3396-01 30 Ce-141 -1.OOE+00 2.00E+00 6.60E+00 STJ L3396-01 30 Ce-144 4.30E+00 3.10E+00 l .OOE+01 STJ 12396-01 30 Co-57 -2.50E-01 4.10E-01 1.40E+00 STJ 12396-01 30 Co-58 -1.54E+00 6.40E-01 2.30E+00 STJ L3396-01 30 Co-60 6.30E-0I 6.OOE-01 2.00E+00 STJ 12396-01 30 Cr-51 -8.30E+00 8.20E+00 2.80E+01 STJ 12396-01 30 Cs-134 3.OOE-01 5.60E-01 1.90E+00 STJ 12396-01 30 Cs-137 -7.SOE-01 5.90E-01 2.10E+00 STJ U3396-01 30 Fe-59 1.70E+00 1.40E+00 4.80E+00
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-169
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
STJ L3396-01 30 GROSS BETA 3.33E+00 8.30E-01 2.30E+00 STJ L3396-01 30 1-131 7.00E-02 1.40E-01 6.202-01 STJ L3396-01 30 K-40 -1.00E+00 1.10E+01 3.60E+01 STJ L3396-01 30 La-140 3.70E+00 2.90E+00 9.70E+00 STJ L3396-01 30 Mn-54 -6.40E-01 6.00E-01 2.10E+00 STJ L3396-01 30 Nb-95 -2.40E+00 1.30E+00 4.60E+00 STJ L3396-01 30 Ru-103 -6.80E-01 7.90E-01 2.70E+00 STJ L3396-01 30 Ru-106 -6.20E+00 5.402+00 1.90E+01 ST] L3396-01 30 Sb-124 -1.60E+00 1.60E+00 5.80E+00 STJ L3396-01 30 Sb- 125 8.00E-01 1.50E+00 4.90E+00 STJ L3396-01 30 Se-75 5.50E-01 7.70E-01 2.60E+00 -
STJ L3396-01 30 Zn-65 1.60E+00 1.80E+00 6.00E+00 STJ L3396-01 30 Zr-95 9.OOE-01 1.10E+00 3.802+00 LTW L3396-02 30 AcTh-228 -1.00-01 3.90E+00 1.30E+01 LTW L3396-02 30 Ag-108m 5.80E-01 6.60E-01 2.20E+00 LTW L3396-02 30 Ag-110m -2.OOE-01 1.1OE+00 4.00E+00 LTW L3396-02 30 Ba-140 7.90E+00 3.70E+00 1.20E+01 LTW L3396-02 30 Be-7 -4.90E+00 8.00E+00 2.80E+01 LTW L3396-02 30 Ce-141 -3.60E+00 2.70E+00 9.30E+00 LTW L3396-02 30 Ce-144 -2.30E+00 4.50E+00 1.50E+01 LTW L3396-02 30 Co-57 O.OOE+00 5.80E-01 2.00E+00 LTW L3396-02 30 Co-58 4.50E-01 9.20E-01 3.10E+00 LTW 12396-02 30 Co-60 -1.32E+00. 9.10E-01 3.30E+00 LTW L3396-02 30 Cr-51 -7.OOE+00 1.20E+01 4.10E+01 LTW L3396-02 30 Cs-134 -1.49E+00 7.90E-01 2.90E+00 LTW L3396-02 30 Cs- 137 7.70E-01 8.70E-01 2.902+00 LTW L3396-02 30 Fe-59 1.40E+00 2.90E+00 1.00E+01 LTW L3396-02 30 GROSS BETA 5.38E+00 8.70E-01 2.20E+00 LTW L3396-02 30 1-131 6.30E-01 3.40E-0O 9.50E-01 LTW L3396-02 30 K-40 7.00E+00 1.30E+01 4.50E+01 LTW L3396-02 30 La- 140 9.10E+00 4.30E+00 1.40E+01 LTW L3396-02 30 Mn-54 -1.48E+00 8.20E-01 3.00E+OO LTW L3396-02 30 Nb-95 4.50E+00 1.80E+00 5.90E+00 LTW L3396-02 30 Ru-103 1.OOE+00 1.IOE+00 3.80E+00 LTW L3396-02 30 Ru-106 1.05E+01 7.90E+00 2.60E+01 LTW L3396-02 30 Sb- 124 -2.40E+00 2.20E+00 8.20E+00 LTW L3396-02 30 Sb-125 -2.90E+00 2.00E+00 7.10E+00 LTW L3396-02 30 Se-75 7.00E-0O 1.1OE+00 3.70E+00 LTW L3396-02 30 Zn-65 7.30E+00 3.40E+00 1.l10+01 LTW L3396-02 30 Zr-95 2.00E-01 1.60E+00 5.50E+00
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-170
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
STJ L3519-01 32 AcTh-228 I.IOE+00 2.10E+00 9.OOE+00 STJ L3519-01 32 Ag-108m 8.10E-01 4.30E-01 1.40E+00 STJ L3519-01 32 Ag-11 Om 3.OOE-02 7.50E-01 2.50E+00 STJ L3519-01 32 Ba-140 -3.90E+00 3.60E+00 1.30E+01 STJ L3519-01 32 Be-7 I.OOE+O1 5.90E+00 1.90E+01 STJ L3519-01 32 Ce-141 8.OOE-01 2.00E+00 6.50E+00 STJ L3519-01 32 Ce-144 1.20E+00 3.10E+00 L.OOE+O1 STJ L3519-01 32 Co-57 -7.OOE-02 4.OOE-01 1.30E+O0 STJ L3519-01 32 Co-58 2.50E-01 6.70E-01 2.30E+O0 STJ L3519-01 32 Co-60 -1.08E+00 5.50E-01 2.OOE+00 STJ L3519-01 32 Cr-51 2.50E+00 9.70E+00 3.30E+I0 STJ L3519-01 32 Cs-134 2.30E-01 5.70E-01 1.90E+00 STJ L3519-01 32 Cs-137 -1.93E+00 5.30E-0I 1.90E+00 STJ L3519-01 32 Fe-59 6.OOE-01 2.20E+00 7.50E+0O STJ L3519-01 32 GROSS BETA 3.58E+00 9.70E-01 2.70E+00 STJ L3519-01 32 1-131 6.OOE-01 4.50E-01 1.50E+00 STJ L3519-01 32 K-40 1.73E+01 9.20E+00 3.0OE+0O STJ L3519-01 32 La-140 -4.50E+00 4.10E+00 1.50E+0O STJ L3519-01 32 Mn-54 2.OOE-02 5.50E-OI 1.90E+00 STJ L3519-01 32 Nb-95 -1.OOE-O1 1.1OE+00 3.90E+00 STJ U3519-01 32 Ru-103 -1.32E+00 8.50E-01 2.90E+00 STJ L35i9-01 32 Ru-106 -3.30E+00 5.OOE+00 1.70E+01 STJ L3519-01 32 Sb-124 -2.40E+00 1.80E+00 6.50E+00 STJ U3519-01 32 Sb-125 1.90E+00 1.30E+00 4.40E+00 STJ U3519-01 32 Se-75 -1.20E+00 7.50E-01 2.60E+00 STJ L3519-01 32 Zn-65 6.60E+00 2.30E+00 7.50E+00 STJ U3519-01 32 Zr-95 I.IOE+O0 1.IOE+O0 3.80E+00 LTW U3519-02 32 AcTh-228 -3.80E+00 3.OOE+O0 l.OOE+01 LTW U3519-02 32 Ag-108m 8.OOE-02 3.80E-01 1.30E+00 LTW L3519-02 32 Ag-1 10m -9.40E-01 6.30E-01 2.20E+0O LTW 12519-02 32 Ba-140 6.90E+00 3.30E+00 l.lOE+01 LTW L3519-02 32 Be-7 1.90E+00 5.30E+00 1.80E+0O LTW U3519-02 32 Ce-141 -6.OOE-01 1.20E+00 3.90E+00 LTW L3519-02 32 Ce-144 -2.20E+00 2.50E+00 8.60E+00 LTW L3519-02 32 Co-57 1.50E-01 6.OOE-01 2.OOE+00 LTW L3519-02 32 Co-58 -1.63E+00 5.80E-01 2.10E+00 LTW L3519-02 32 Co-60 -9.OOE-01 4.70E-01 1.70E+00 LTW L3519-02 32 Cr-51 7.20E+00 8.40E+00 2.80E+0O
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-171
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
LTW L3519-02 32 Cs-134 7.OOE-01 4.80E-01 1.60E+00 LTW L3519-02 32 Cs-137 -2.80E-0O 4.90E-01 1.70E+00 LTW L3519-02 32 Fe-59 4.00E-01 2.00E+00 6.90E+00 LTW L3519-02 32 GROSS BETA 3.OOE+00 1.00E+00 2.90E+00 LTW L3519-02 32 1-131 2.50E-01 4.OOE-01 1.60E+00 LTW L3519-02 32 K-40 -6.OOE+00 l.l1OE+01 3.70E+01 LTW L3519-02 32 La-140 8.OOE+00 3.70E+00 1.20E+01 LTW L3519-02 32 Mn-54 4.00E-02 4.50E-01 1.502+00 LTW L3519-02 32 Nb-95 1.60E+00 1.30E+00 4.40E+00 LTW L3519-02 32 Ru-103 -3.04E+00 7.70E-01 2.80E+00 LTW L3519-02 32 Ru-106 4.90E+00 4.60E+00 1.50E+01 LTW L3519-02 32 Sb-124 -2.30E+00 1.501E+00 5.30E+00 LTW L3519-02 32 Sb- 125 -1.OOE+00 1.20E+00 4.00E+00 LTW L3519-02 32 Se-75 7.50E-01 5.60E-01 1.90E+00 LTW L3519-02 32 Zn-65 -1.OOE+00 1.40E+00 4.80E+00 LTW L3519-02 32 Zr-95 1.lOE+00 1.10E+00 3.60E+00 STJ L3637-01 34 AcTh-228 -7.10E+00 4.60E+00 1.70E+0O STJ L3637-01 34 Ag-108m 2.21E+00 8.30E-01 2.60E+00 STJ L3637-01 34 Ag-i lim -1.00E+00 1.40E+00 5.00E+00 STJ L3637-01 34 Ba-140 l .OOE-0l 2.10E+00 7.80E+00 STJ L3637-01 34 Be-7 2.20E+00 9.OOE+00 3.10E+01 STJ L3637-01 34 Ce-141 -4.101E+00 2.OOE+00 7.00E+00 STJ L3637-01 34 Ce-144 8.70E+00 5.60E+00 1.80E+01 STJ L3637-01 34 Co-57 1.lOE-01 8.80E-01 3.00E+00 STJ L3637-01 34 Co-58 -1.04E+00 9.10E-01 3.50E+00 STJ L3637-01 34 Co-60 1.30E+00 1.lOE+00 3.50E+00 STJ L3637-01 34 Cr-51 l.OOE+00 1.lOE+01 3.80E+01 STJ L3637-01 34 Cs-134 -I.OOE-01 1.00E+00 3.70E+00 STJ L3637-01 34 Cs-137 -4.OOE-0O 1.10E+00 4.00E+00 STJ. L3637-01 34 Fe-59 l.OOE-0O 3.30E+00 1.20E+01 STJ L3637-01 34 GROSS BETA 5.1OE+00 1.10+00 3.00+E+0 STJ L3637-01 34 1-131 -3.00E-02 1.70E-01 1.00E+00 STJ L3637-01 34 K-40 I.OOE+00 1.60E+01 5.702+01 STJ L3637-01 34 La-140 2.00E-01 2.40E+00 9.00E+00 STJ L3637-01 34 Mn-54 2.OOE-01 l.OOE+00 3.502+00 STJ L3637-01 34 Nb-95 -1.20E+00 1.30E+00 4.90E+00 STJ 12637-01 34 Ru-103 O.OOE+00 1.20E+00 4. 1OE+00 STJ L3637-01 34 Ru-106 -2.73E+01 9.90E+00 3.80E+01
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-172
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
STJ U3637-01 34 Sb-124 4.701E+00 2.80E+00 9.OOE+00 STJ U3637-01 34 Sb-125 1.20E+00 2.70E+00 9.20E+00 STJ 1U637-01 34 Se-75 1.30E+00 1.20E+00 3.90E+O0 STJ U3637-01 34 Zn-65 1.13E+0lI 4.30E+00 1.40E+01 STJ U3637-01 34 Zr-95 I1.30E+00 1.80E+00 6.20E+00 LTW U3637-02 34 AcTh-228 -7.80E+00 4.30E+00 1.60E+01 LTW U3637-02 34 Ag-108m -7.OOE-02 9.OOE-01 3.20E+00 LTW 12637-02 34 Ag-110m -1 .20E+00 1.50E+00 5.70E+00 LTW U3637-02 34 Ba-140 7.00OE-01 2.50E+00 9.10E+00 LTW L3637-02 34 Be-7 -8.501E+00 9.20E+00 3.40E+0O LTW U3637-02 34 Ce-141 3.OOE-01 1.80E+00 6.30E+00 LTW L3637-02 34 Ce-144 -2.80E+00 6.30E+00 2.20E+0O LTW 12637-02 34 Co-57 -4.70E-01 8.20E-01 2.80E+00 LTW L3637-02 34 Co-58 0.OOE+00 l.OOE+00 3.70E+00 LTW L3637-02 34 Co-60 1.40E+00 1.IOE+00 3.70E+00 LTW L3637-02 34 Cr-51 -2.001E+00 1.20E+01 4.30E+0O LTW L3637-02 34 Cs-134 1.60E+00 1. 1OE+00 3.70E+00 LTW L3637-02 34 Cs-137 -1 .40E+00 1.20E+00 4.50E+00 LTW L3637-02 34 Fe-59 -3.201E+00 3.40E+00 1.30E+01 LTW L3637-02 34 GROSS BETA 2.71E+00 9.90E-01 3.OOE+00 LTW L3637-02 34 1-131 4.001E-02 2.10E-01 1.20E+00 LTW L3637-02 34 K-40 -2.201E+01 1.50E+01 5.50E+01 LTW L3637-02 34 La-140 8.00OE-01 2.90E+00 I.OOE+01 LTW L3637-02 34 Mn-54 5.00OE-01 l.1OE+00 3.80E+00 LTW L3637-02 34 Nb-95 -2.30E-i00 1.60E+00 5.90E+00 LTW L3637-02 34 Ru-103 4.OOE-01 1.30E+00 4.50E+00 LTW L3637-02 34 Ru-106 -1.80E+01 l.1OE+01 4.1OE+OI LTW L3637-02 34 Sb-124 -2. 10E+00 3.10E+00 1.20E+0O LTW L3637-02 34 Sb-12S 4.80E+00 2.90E+00 9.50E+00 LTW L3637-02 34 Se-75 3.OOE-01 1.40E+00 4.90E+00 LTW L3637-02 34 Zn-65 0.OOE+00 3.OOE+00 I.IOE+OI LTW L3637-02 34 Zr-95 -5.OOE-01 l.90E+00 6.90E+00 STJ L3733-01 36 AcTb-228 -1.OOE-01 3.60E+00 1.30E+01 STJ L3733-01 36 Ag-108m -9.00E-02 7.60E-01 2.60E+00 STJ L3733-01 36 Ag-11 Om 1.30E+00 1.30E+00 4.30E+00 STJ L3733-01 36 Ba-140 8.OOE-01 l.90E+00 6.80E+00 STJ L3733-01 36 Be-7 0.OOE3+00 7.90E+00 2.70E+0O STJ 12733-01 36 Ce-141 2.70E+00 2.00E+00 6.50E+00
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-173
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
STJ L3733-01 36 Ce-144 3.20E+00 5.40E+00 1.80E+01 STJ L3733-01 36 Co-57 4.70E-01 6.90E-01 2.30E+00 STJ L3733-01 36 Co-58 -2.30E+00 1.00E+00 3.80E+00 STJ L3733-01 36 Co-60 -9.00E-02 9.70E-01 3.40E+00 STJ L3733-01 36 Cr-51 -4.60E+00 9.90E+00 3.40E+0O STJ L3733-01 36 Cs-134 1.00E-01 1.00E+00 3.50E+00 STJ L3733-01 36 Cs-137 -1.12E+00 9.40E-01 3.40E+00 STJ L3733-01 36 Fe-59 1.OOE-01 2.50E+00 8.80E+00 STJ L3733-01 36 GROSS BETA 2.30E+00 1.OOE+00 3.10E+00 STJ L3733-01 36 1-131 3.60E-01 2.90E-01 1.00E+00 STJ L3733-01 36 K-40 1.00E+0 1.50E+01 5.20E+01 STJ L3733-01 36 La-140 I.OOE+00 2.20E+00 7.80E+00 STJ L3733-01 36 Mn-54 4.60E-01 9.50E-01 3.30E+00 STJ L3733-01 36 Nb-95 -2.30E+00 1.80E+00 6.50E+00 STJ L3733-01 36 Ru-103 7.00E-01 1.IOE+00 3.60E+00 STJ L3733-01 36 Ru-106 -8.OOE+00 8.90E+00 3.10E+01 STJ L3733-01 36 Sb-124 -5.00E-01 2.50E+00 9.OOE+00 STJ L3733-01 36 Sb-125 1.30E+00 2.40E+00 8.10E+00 STJ L3733-01 36 Se-75 5.OOE-01 1.20E+00 4.20E+00 STJ L3733-01 36 Zn-65 5.80E+00 3.90E+00 1.30E+01 STJ 12733-01 36 Zr-95 -2.OOE+00 1.60E+00 6.00E+00 LTW L3733-02 36 AcTh-228 1.08E+01 5.20E+00 1.70E+01 LTW 12733-02 36 Ag-108m -7.00E-01 1.00E+00 3.60E+00 LTW L3733-02 36 Ag- 10m -5.00E-01 1.80E+00 6.30E+00 LTW L3733-02 36 Ba-140 -5.40E+00 2.80E+00 1.20E+01 LTW 12733-02 36 Be-7 -3.30E+00 9.80E+00 3.50E+0I LTW L3733-02 36 Ce-141 -4.60E+00 3.00E+00 1.1OE+01 LTW L3733-02 36 Ce-144 1.50E+00 6.10E+00 2.10E+01 LTW 12733-02 36 Co-57 6.30E-01 7.70E-01 2.60E+00 LTW 12733-02 36 Co-58 -2.00E+00 1.30E+00 4.90E+00 LTW 12733-02 36 Co-60 2.10E+00 1.50E+00 4.80E+00 LTW L3733-02 36 Cr-51 -1.00+00 1.30E+01 4.40E+01 LTW L3733-02 36 Cs-134 -1.40E+00 1.30E+00 4.90E+00 LTW 12733-02 36 Cs-137 3.00E-01 1.30E+00 4.50E+00 LTW L3733-02 36 Fe-59 1.40E+00 4.00E+00 1.40E+01 LTW U3733-02 36 GROSS BETA 3.60E+00 1.10E+00 3.00E+00 LTW U3733-02 36 1-131 -3.00E-01 1.30E-01 1.00E+00 LTW 12733-02 36 K-40 -1.70E+01 2.00E+01 7.20E+01 LTW 12733-02 36 La-140 -6.20E+00 3.20E+00 1.30E+01 LTW L3733-02 36 Mn-54 -1.40E+00 1.30E+00 4.70E+00
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-174
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Sumnmary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
LTW U3733-02 36 Nb-95 -9.OOE-01 1.40E+00 5.OOE+00 LTW U3733-02 36 Ru-103 -2.90E+00 1.30E+00 4.80E+00 LTW U3733-02 36 Ru-106 1.90E+01 1.20E+01 4.OOE+01 LTW U3733-02 36 Sb-124 -2.60E+00 3.50E+00 1.40E+01 LTW U3733-02 36 Sb-125 -9.OOE-01 3.30E+00 I. lO+01 LTW U3733-02 36 Se-75 6.OOE-01 I1.50E+00 5.OOE+00 LTW U3733-02 36 Zn-65 -9.OOE-01 5.OOE+00 1.80E+01 LTW U3733-02 36 Zr-95 2.70E+00 2.10oE+00 7.101E+00 ST1 U3864-01 37 AcTh-228 6.OOE+00 2.90E+00 1.30E+01 STJ U3864-01 37 Ag- 108m 6.20E-01 6.60E-01 2.20E+00 STJ U3864-01 37 Ag-110m *IOE+00 I1.30E+00 4.20E+00 STJ U3864-01 37 Ba-140 3.OOE+00 2.90E+00 9.90E+00 STJ U864-01 37 Be-7 8.60E+00 8.50E+00 2.80E+01 STJ U3864-01 37 Ce-141 2.OOE-01 1.90E-.00 6.30E+00 STJ U3864-01 37 Ce-144 3.70E+00 5.20E+00 1 .70E+01 STJ U3864-01 37 Co-57 9. 1O-01 6.70E-01 2.20E+00 STJ 12864-01 37 Co-58 5.OOE-02 9.40E-01 3.20E+00 STJ U3864-01 37 Co-60 8.OOE-01 7.90E-01 2.70E+00 STJ U3864-01 37 Cr-51 -1.1E+01 l.IOE-s01 3.70E+01 STJ U3864-01 37 Cs-134 I1.40E+00 1.90E+00 6.30E+00 STJ U3864-01 37 Cs-137 -1.95E+00 8.40E-01 3.OOE+00 STJ L3864-01 37 Fe-59 2.80E+00 2.OOE+00 6.50E+00 STJ L3864-01 37 GROSS BETA 5.80E+00 I1.20E+00 300OE+00 STJ L3864-01 37 1-131 2.70E-01 2.60E-01 9.50E-01 STJ L3864-01 37 K-40 -8.OOE+00 1.40E+01 4.80E+01 STJ L3864-01 37 La-140 3.40E+00 3.40E+00 I. IOE+01 STJ L3864-01 37 Mn-54 -7.90E-01 8.70E-01 3. 1OE+00 STJ L3864-01 37 Nb-95 3.901E+00 I1.60E+00 5.10E+00 STJ L3864-01 37 Ru-103 -6.OOE-01 1.IOE+00 3.80E+00 STJ U3864-01 37 Ru-106 -3.70E+00 7.40E+00 2.60E-i01 STJ L3864-01 37 Sb-124 -2. l OE+00 2.40E+00 8.80E+60 STJ L3864-01 37 Sb-125 2.40E+O0 2.OOE+00 6.80E+00 STJ U3864-01 37 Se-75 -I. lOE+00 LIO0E+00 3.90E+00 STJ U3864-01 37 Zn-65 -8.OOE-01 1.60E+00 5.70E+00 STJ U3864-01 37 Zr-95 -8.OOE-01 1.60E+00 5.70E+00 LTW 12864-02 37 AcTh-228 2.30E+00 4.OOE+00 1.40E+0 I LTW 12864-02 37 Ag-108m -6.OOE-01 7.40E-01 2.60E+00 LTW L3864-02 37 Ag-I 10m -1.80E+00 1.50E+00 5.50E+00
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-175
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
LTW L3864-02 37 Ba-140 -4.00E-0O 3.40E+00 1.20E+01 LTW L3864-02 37 Be-7 -9.1OE+00 9.20E+00 3.20E+01 LTW L3864-02 37 Ce-141 -4.90E+00 2.70E+00 9.20E+00 LTW L3864-02 37 Ce-144 -2.30E+00 4.90E+00 1.70E+01 LTW L3864-02 37 Co-57 -1.80E-0O 6.20E-0O 2.10E+00 LTW L3864-02 37 Co-58 7.00E-01 l.lOE+00 3.60E+00 LTW L3864-02 -37 Co-60 1.30E1+OO 1. lOE+00 3.50E+00 LTW L3864-02 37 Cr-51 -4.OOE+00 1.20E+0O 4.10E+01 LTW L3864-02 37 Cs-134 -1.IOE+00 l.lOE+00 4.10E+00 LTW L3864-02 37 Cs-137 -6.90E-0O 9.60E-0O 3.40E+00 LTW L3864-02 37 Fe-59 -1.80E+00 2.40E+00 8.70E+00 LTW L3864-02 37 GROSS BETA 5.OOE+00 -1.20E+00 3.1OE+00 LTW L3864-02 37 1-131 -2.09E-0I 3.60E-02 9.40E-0O LTW L3864-02 37 K-40 -2.00E+00 1.70E+0O 5.80E+01 LTW L3864-02 37 La-140 -4.OOE-01 3.90E+0O 1.40E+I01 LTW L3864-02 37 Mn-54 -2.90E-0O 9.80E-0I 3.50E+00 LTW L3864-02 37 Nb-95 -1.30E+00 1.30E+00 4.60E+00 LTW L3864-02 37 Ru-103 -I.OOE-0O 1.20E3+00 4.20E+00 LTW L3864-02 37 Ru-106 -1.20E+0O 8.80E+00 3.10E+01 LTW L3864-02 37 Sb-124 -2.10E+00 2.90E+00 l.10E+01 LTW L3864-02 37 Sb- 125 -2.50E+00 2.40E+00 8.30E+00 LTW L3864-02 37 Se-75 0.OOE+00 1.20E+00 3.90E+00 LTW L3864-02 37 Zn-65 3.60E+00 3. 10E+00 l.OOE+0O LTW L3864-02 37 Zr-95 -I.IOE+00 1.90E+00 6.80E+00 STJ L3970-01 40 AcTh-228 9.OOE+00 5.60E+00 1.80E3+01 STJ L3970-01 40 Ag-108m -5.00E-0O l.lOE+00 4. 1OE+00 STJ L3970-01 40 Ag-I lOm -1.70E+00 1.60E+00 6.60E+00 STJ 12970-01 40 Ba-140 2.40E+00 3.101E+00 1.lOE+01 STJ 12970-01 40 Be-7 l.lOE+0I 1.30E+0O 4.50E+0I STJ 12970-01 40 Cc-141 7.00E-0O 3.20E+00 l.lOE+0I STJ 12970-01 40 Ce-144 -9.OOE+OO l.lOE+01 3.90E+01 STJ 12970-01 40 Co-57 2.00E+00 1.40E+00 4.50E+00 STJ L3970-01 40 Co-58 -1.0E1+-00 1.30E+00 5.00E+00 STJ L3970-01 40 Co-60 l.OOE-0O 1.20E+00 4.60E+00 STJ L3970-01 40 Cr-51 2.OOE+00 1.60E+0O 5.50E+0O STJ W3970-01 40 Cs-134 I.IOE+00 1.30E+00 4.60E+00 STJ L3970-01 40 Cs-137 -3.00E+00 1.20E+00 5.30E+00 STJ 12970-01 40 Fe-59 -1.50E+00 3.60E+00 1.40E+01
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-176
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
STJ L3970-01 40 GROSS BETA 3.50E+00 I.IOE+00 3.10E+00 STJ L3970-01 40 1-131 -I.OOE-0I 1.60E-01 9.10E-0O STJ L3970-01 40 K-40 -2.50E+0O 1.50E+OI 6.50E+01 STJ L3970-oi 40 La-140 2.70E+00 3.60E+00 1.30E+01 STJ L3970-01 40 Mn-54 1.20E+00 1.30E+00 4.70E+00 STJ L3970-01 40 Nb-95 3.10E+00 1.90E+00 6.30E+00 STJ L3970-01 40 Ru-103 -1.80E+00 1.70E+00 6.30E+00 STJ L3970-01 40 Ru-106 1.30E+0O 1.30E+0O 4.40E+01 STJ L3970-01 40 Sb-124 .lOE+00 3.1OE+00 1.20E+0O STJ L3970-01 40 Sb-125 4.OOE-01 3.50E+00 1.30E+0l STJ L3970-01 40 Se-75 -4.20E+00 2.OOE+00 7.40E+00 STJ L3970-01 40 Zn-65 5.OOE+00 4.80E+00 1.60E+0l STJ L3970-01 40 Zr-95 -7.OOE-0O 2.20E+00 8.50E+00 LTW L3970-02 40 AcTh-228 1.20E+00 6.60E+00 2.40E+0O LTW L3970-02 40 Ag-108m -9.OOE-0O 1.30E+00 5.OOE+OO LTW L3970-02 40 Ag-lOmn -4.30E+00 2.10E+00 9.OOE+00 LTW L3970-02 40 Ba-140 -4.OOE-01 2.60E+00 1.1OE+01 LTW L3970-02 40 Be-7 -2.OOE+0O 1.60E+0O 6.10E+0l LTW L3970-02 40 Ce-141 4.80E+00 3.80E+00 1.30E+0O LTW L3970-02 40 Ce-144 1.60E+01 1.30E+0O 4.40E+0O LTW L3970-02 40 Co-57 1.60E+00 1.70E+00 5.60E+00 LTW L3970-02 40 Co-58 -3.30E+00 1.60E+00 6.60E+00 LTW L3970-02 40 Co-60 1.40E+00 1.70E+00 5.90E+00 LTW L3970-02 40 Cr-SI 9.OOE+00 l.90E+01 6.60E+0O LTW L3970-02 40 Cs-134 -2.20E+00 l.90E+00 7.30E+00 LTW L3970-02 40 Cs-137 -1.60E+00 1.50E+00 6.OOE+00 LTW L3970-02 40 Fe-59 -3.60E+00 3.90E+00 1.70E+01 LTW L3970-02 40 GROSS BETA 2.OOE+00 9.70E-0O 3.OOE+00 LTW L3970-02 40 1-131 -5.OOE-02 1.70E-0O 9.30E-0O LTW L3970-02 40 K-40 -1.80E+0l 1.80E+0O 7.20E+01 LTW L3970-02 40 La-140 -5.OOE-0O 3.OOE+00 1.20E+01 LTW L3970-02 40 Mn-54 1.OOE+00 1.80E+00 6.30E+00 LTW L3970-02 40 Nb-95 2.20E+00 2.30E+00 7.80E+00 LTW L3970-02 40 Ru-103 -1.90E+00 1.70E+00 6.SOE+00 LTW L3970-02 40 Ru-106 -6.OOE+00 1.40E+0O 5.20E+01 LTW L3970-02 40 Sb-124 6.90E+00 4.60E+00 1.50E+01 LTW L3970-02 40 Sb-125 9.OOE-01 3.80E+00 1.40E+0I LTW L3970-02 40 Se-75 -1.80E+00 2.60E+00 9.10E+00 LTW L3970-02 40 Zn-65 7.70E+00 6.70E+00 2.30E+0l LTw L3970-02 40 Zr-95 -3.1OE+00 2.70E+00 1.1OE+0l
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-177
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
STJ L4120-01 41 AcTh-228 -4.50E+00 4.80E+00 1.90E+01 STJ L4120-01 41 Ag-108m 2.00E-01 1.10E+00 4.10E+00 STJ L4120-01 41 Ag-110m 5.00E-01 1.80E+00 6.60E+00 STJ L4120-01 41 Ba-140 -4.40E+00 2.80E+00 1.20E+01 STJ LA120-01 41 Be-7 1.30E+OI 1.lOE+0I 3.70E+0O STI L4120-01 41 Ce-141 -3. 10E+00 2.90E+00 1.OOE+01 STJ L4120-01 41 Ce-144 3.OOE+00 1.OOE+01 3.40E+01 STJ L4120-01 41 Co-57 -9.OOE-01 1.20E+00 4.30E+00 STJ L4120-01 41 Co-58 -2.10E+00 1.lOE+00 4.80E+00 STJ L4120-01 41 Co-60 -1.89E+00 9.70E-01 4.70E+00 STJ L4120-01 41 Cr-51 -1.80E+01 1.40E+01 5.30E+01 STJ L4120-01 41 Cs-134 -1.90O+00 1.30E+00 5.50E+00 STJ L4120-01 41 Cs-137 -1.80E+00 1.30E+00 5.30E+00 STJ L4120-0i 41 Fe-59 1.80E+00 2.80E+00 I.OOE+01 STJ L4120-01 41 GROSS BETA -3. 1OE-0I 8.50E-01 3.10E+00 STJ L4120-01 41 1-131 1.70E-01 2.70E-01 9.70E-OI STJ L4120-01 41 K-40 -1.50E+01 1.50E+01 6.20E+01 STJ L4120-01 41 La-140 -5.10E+00 3.20E+00 1.40E+01 STJ LA120-01 41 Mn-54 -1.60E+00 1.20E+00 4.90E+00 STJ L4120-01 41 Nb-95 2.10E+00 1.40E+00 4.70E+00 STJ L4120-01 41 Ru-103 -3.80E+00 1.60E+00 6.30E+00 STJ L4120-01 41 Ru-106 -4.70E+00 9.90E+00 3.80E+01 STJ L4120-01 41 Sb-124 -5.50E+00 3.10E+00 1.40E+OI STJ LA120-01 41 Sb-125 -1.30E+00 3.50E+00 1.30E+I01 STJ L4120-01 41 Se-75 7.OOE-01 1.80E+00 6.10E+00 STJ UA120-01 41 Zn-65 -4. 10E+00 2.80E-+00 1.20E+01 STJ LA120-01 41 Zr-95 1.501E+00 2.20E+00 7.80E+00 LTW LA120-02 41 AcTh-228 3.00E-01 4.30E+00 1.60E+01 LTW LA120-02 41 Ag-108m -3.40E-01 9.60E-01 3.50E+00 J LTW LA120-02 41 Ag-110m -1.70E+00 1.402+00 5.602+00 LTW LA120-02 41 Ba- 140 O.OOE+00 2.30E+00 9.00E+00 LTW LA120-02 41 Be-7 8.00E+00 1.OOE+01 3.50E+0I LTW LA120-02 41 Ce-141 -2.20E+00 2.502+00 8.90E+00 LTW LA1 20-02 41 Ce-144 -6.00E+00 8.00E+00 2.80E+0O LTW LA1 20-02 41 Co-57 -1 .OOE+00 1.002+00 3.70E+00 LTW LA120-02 41 Co-58 -1.60E+00 1.IOE+00 4.40E+00 LTW L4120-02 41 Co -1.46E+00 9.20E-01 4.10E+00 LTW L4120-02 41 Cr-51 2.00E+00 1.30E+01 4.60E+01
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-178
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
LTW L4120-02 41 Cs-134 7.OOE-01 1.30E+00 4.501E+00 LTW L4120-02 41 Cs-137 6.00E-01 1.20E+00 4. 10E+00 LTW L4120-02 41 Fe-59 -2.OOE-01 2.90E+00 1.1OE+01 LTW L4120-02 41 GROSS BETA 2.49E+00 9.90E-01 3.10E+00 LTW L4120-02 41 1-131 2.40E-01 2.60E-01 9.10E-01 LTW L4120-02 41 K-40 Q.OOE+00 1.50E+01 5.50E+01 LTW L4120-02 41 La-140 O.OOE+00 2.70E+00 1.OOE1+01 LTW LU120-02 41 Mn-54 3.OOE-01 1.IOE+00 3.90E+00 LTW L4120-02 41 Nb-95 -1.60E+00 1.30E+00 5.30E+00 LTW L4120-02 41 Ru-103 -1.OOE+00 1.30E+00 5.OOE+00 LTW LU120-02 41 Ru-106 -1.OOE+01 1.OOE+01 3.90E+01 LTW L4120-02 41 Sb-124 -1 .20E+00 2.90E4-00 1.201E+01 LTW L4120-02 41 Sb-125 -3.10E+00 2.90E+00 I. IOE+01 LTW LA120-02 41 Se-75 -3.10E+00 1.60E+00 6.10OE+00 LTW LA120-02 41 Zn-65 7.60E+00 4.701E+00 1.60E+01 LTW L4120-02 41 Zr-95 -1.OOE-01 1.90E+00 7.10OE+00 STJ L4228-01 43 AcTh-228 -9.OOE-01 3.80E+00 1.40E+01 STJ U4228-01 43 Ag-108m 1.80E-01 8.30E-01 2.90E+00 STJ U4228-01 43 Ag-l lOm -1.OOE-01 1.20E+00 4.601E+00 STJ LA228-01 43 Ba-140 -3.60E+00 2.40E+00 1.OOE+01 STJ UA228-01 43 Be-7 -5.30E+00 9.60E+00 3.50E+01 STJ LA228-01 43 Ce-141 1.40E+00 2. 10E+00 7.OOE+00 STJ 1A228-01 43 Ce-144 3.OOE+00 6.60E4-00 2.30E+01 STJ LA228-01 43 Co-57 1.OOE-01 8.601E-01 3.OOE+00 STJ UA228-01 43 Co-58 -1 .56E+00 9.20E-01 3.80E+00 STJ L4228-01 43 Co-60 -9.70E-01 9.70E-01 3.90E+00 STJ L4228-01 43 Cr-51 9.OOE+00 1.10E+01 3.80E+01 STJ LA228-01 43 Cs-134 -2.60E-0I 9.40E3-01 3.50E+00 STJ UA228-01 43 Cs-137 -1 .34E+00 9.70E-01 3.80E+00 STJ LA228-01 43 Fe-59 -7.OOE-OI 2.40E+00 8.90E+00 STJ 14228-01 43 GROSS BETA 2.80E+00 I.OOE+00 3.OOE+00 STJ UA228-01 43 1-131 5.10E-OI 3.30E-01 9.40E-01 STJ UA228-01 43 K-40 -1.90E+01 1.30E+01 5. 10E+01 STJ LA228-01 43 La-140 -4. 1OE+00 2.80E+O0 1.20E+01 STJ LA228-01 43 Mn-54 -5.OOE-0I 8.30E-01 3.2013-00 STJ UA228-01 43 Nb-95 -4.OOE-01 I1.30E+00 4.80E+00 STJ LA228-01 43 Ru-103 -2.90E+00 I1.30E+00 5.OOE+00 STJ LA228-01 43 Ru-106 -1 .99E+01 9.50E+00 3.80E+01
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-179
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
STJ L4228-01 43 Sb-124 0.OOE+00 2.80E+00 1. IOE+0O STJ L4228-01 43 Sb-125 0.00+00 2.70E+00 9.50E+00 STJ L4228-01 43 Se-75 -7.00E-01 1.10E+00 4.10E+00 STJ L4228-01 43 Zn-65 l.OOE+00 2.90E+00 l .00+01 STJ L4228-01 43 Zr-95 -3.00E-01 1.80E+00 6.80E+00 LTW L4228-02 43 AcTh-228 -5.20E+00 4.50E+00 1.80E+0O LTW L4228-02 43 Ag-108m 4.80E-01 9.10E-01 3.20E+00 LTW L4228-02 43 Ag- lOnm -7.00E-01 1.50E+00 5.70E+00 LTW L4228-02 43 Ba-140 6.00E-01 3.40E+O0 1.30E+01 LTW L4228-02 43 Be-? -5.70E+00 9.90E3+00 3.70E+01 LTW L4228-02 43 Ce-141 2.40E+00 2.10E+00 7.00E+00 LTW L4228-02 43 Ce-144 3.70E+00 6.70E+00 2.30E+01 LTW L4228-02 43 Co-57 5.50E-0O 8.10E-0O 2.70E+00 LTW L4228-02 43 Co-58 -1.30E+00 1.1 OE+0O 4.40E+00 LTW L4228-02 43 Co-60 2.40E+00 l.00E+00 3.20E+00 LTW L4228-02 43 Cr-51 1.60E+0O 1.40E+01 4.60E+01 LTW L4228-02 43 Cs-134 l.OOE+00 1.1OE+00 3.90E+00 LTW LA228-02 43 Cs-137 -I .OOE-0O 1.20E+00 4.30E+00 LTW L4228-02 43 Fe-59 3.00E+00 2.40E+00 8.20E+00 LTW L4228-02 43 GROSS BETA 1.84E+00 9.20E-01 2.90E+00 LTW L4228-02 43 1-131 3.50E-01 2.80E-01 9.40E-O1 LTW L4228-02 43 K-40 1.50E+01 1.40E+01 4.60E+01 LTW L4228-02 43 La-140 7.00E-OI 3.90E+00 1.40E+01 LTW L4228-02 43 Mn-54 -9.00E-01 1.lE+00 4.10E+00 LTW L4228-02 43 Nb-95 -8.00E-0O 1.50E+00 5.70E+00 LTW L4228-02 43 Ru-103 -2.OOE+00 1.40E+00 5.30E+00 LTW L4228-02 43 Ru-106 -1.85E+O1 9.70E+00 3.90E+01 LTW L4228-02 43 Sb-124 3.30E+00 2.90E+00 9.90E+00 LTW L4228-02 43 Sb-125 3.50E+00 2.80E+00 9.50E+00 LTW L4228-02 43 Se-75 -2.00E-01 1.50E+00 5.20E+00 LTW L4228-02 43 Zn-65 -5.80E+00 2.70E+00 1.10E+01 LTW L4228-02 43 Zr-95 -2.50E+00 1.90E+00 7.70E+00 STJ L4315-01 45 AcTh-228 -4.60E+00 4.90E+00 1.80E+01 STJ L4315-01 45 Ag-108m -7.00E-02 9.20E-01 3.20E+00 STJ L4315-01 45 Ag-I lOIm -2.00E-01 1.60E+00 5.70E+00 STJ L4315-01 45 Ba- 140 4.70E+O0 2.70E+00 8.60E+00 STJ L4315-01 45 Be-7 2.00E+00 1.00+01 3.50E+01 STJ L4315-01 45 Ce-141 -1.80E+O0 1.90E+00 6.50E+00
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-180
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
STJ L4315-01 45 Ce-144 6.40E+00 5.70E+00 1.90E+0O STJ L4315-01 45 Co-57 5.OOE-01 7.60E-01 2.50E+00 STJ L4315-01 45 Co-58 -1.50E+00 1.20E+00 4.50E+00 STJ L4315-01 45 Co-60 1.60E+00 1.50E+00 5.20E+00 STJ L4315-01 45 Cr-51 -6.OOE+00 1.20E+01 4.1OE+Ol STJ L4315-01 45 Cs-134 8.OOE-01 1.30E+00 4.50E+00 STJ L4315-01 45 Cs-137 -1.90E+00 1.30E+00 4.70E+00 STJ L4315-01 45 Fe-59 1.60E+00 2.60E+00 9.10E+00 STJ L4315-01 45 GROSS BETA 2.42E+00 9.40E-01 2.90E+00 STJ L4315-01 45 1-131 I.OOE-02 1.70E-01 8.60E-0O STJ L4315-01 45 K-40 3.90E+01 2.OOE+01 6.50E+0I STJ L4315-01 45 La-140 5.40E+00 3.10E+00 9.90E+00 STJ L4315-01 45 Mn-54 -5.OOE-01 1.20E+00 4.20E+00 STJ L4315-01 45 Nb-95 -1.50E+00 1.60E+00 6.OOE+00 STJ L4315-01 45 Ru-103 7.OOE-01 1.20E+00 4.OOE+00 STJ L4315-01 45 Ru-106 I.OOE+0O l.lOE+0 3.70E+0 STJ L4315-01 45 Sb-124 5.OOE-01 3.40E+00 1.20E+0O STJ L4315-01 45 Sb-125 -2.80E+00 2.80E+00 I.OOE+0O STJ L4315-01 45 Se-75 -1.OOE+00 1.40E+00 4.80E+00 STJ L4315-01 45 Zn-65 -3.60E+00 2.90E+00 I.1OE+01 STJ L4315-01 45 Zr-95 7.00E-01 2.20E+00 7.60E+00 LTW LA315-02 45 AcTh-228 L.OOE-01 3.30E+00 1.lOE+0O LTW L4315-02 45 Ag-108m -2.60E-01 6.70E-01 2.30E+00 LTW L4315-02 45 Ag-1 10m -l.OOE+00 l.OOE+00 3.70E+00 LTW L4315-02 45 Ba-140 -1.70E+00 1.50E+00 5.60E+00 LTW L4315-02 45 Be-7 4.OOE-01 6.70E+00 2.30E+0O LTW L4315-02 45 Ce-141 I.OOE+00 1.80E+00 6.10E+00 LTW L4315-02 45 Ce-144 2.20E+00 4.60E+00 1.50E+01 LTW L4315-02 45 Co-57 -7.80E-01 5.80E-01 2.OOE+00 LTW L4315-02 45 Co-58 1.30E+00 8.40E-01 2.80E+00 LTW L4315-02 45 Co-60 -8.70E-01 8.90E-01 3.20E+00 LTW L4315-02 45 Cr-51 5.70E+00 8.60E+00 2.90E+0O LTW L4315-02 45 Cs-134 1.48E+00 8.40E-01 2.70E+O0 LTW L4315-02 45 Cs-137 5.OOE-01 8.10E-01 2.70E+00 LTW L4315-02 45 Fe-59 -I.OOE-0O 1.80E+00 6.40E+00 LTW L4315-02 45 GROSS BETA 2.50E+00 I.OOE+00 3.10E+00 LTW L4315-02 45 1-131 3.OOE-01 2.30E-01 7.80E-01 LTW L4315-02 45 K-40 -1.90E+01 1.20E+01 4.40E+0O LTW L4315-02 45 La-140 -1.90E+00 1.70E+00 6.50E+OO LTW L4315-02 45 Mn-54 -4.OOE-01 7.80E-01 2.70E+OO
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-181
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
LTW L4315-02 45 Nb95 -2.20E+00 1.50E+00 5.20E+00 LTW L4315-02 45 Ru-103 -6.00E-01 8.302-01 2.90E+00 LTW L4315-02 45 Ru-106 -1.73E+01 7.00E+00 2.602+01 LTW L4315-02 45 Sb-124 1.90E+00 2.101E+00 7.102+00 LTW L4315-02 45 Sb-125 -2.50E+00 2.00E+00 7.102+00 LTW L4315-02 45 Se-75 5.00E-01 1.00E+00 3.402+00 LTW L4315-02 45 Zn-65 1.90E+00 3.50E+00 1.20E+01 LTW L4315-02 45 Zr-95 1.30E+00 1.40E+00 4.70E+00 STJ L4426-01 47 AcTh-228 8.80E+00 6.00E+00 2.00E+01 STJ L4426-01 47 Ag-108m -1.30E+00 l.00E+00 3.60E+00 STJ L4426-01 47 Ag-I lOm -2.40E+00 1.70E+00 6.302+00 STJ L4426-01 47 Ba- 140 -4.00E-01 2.60E+00 9.802+00 STJ L4426-01 47 Be-7 -1.60E+01 1.20E+01 4.30E+01 STJ L4426-01 47 Ce-141 2.70E+00 1.90E+00 6.1 OE+00 STJ L4426-01 47 Ce-144 -5.102+00 5.90E+00 2.10E+01 STJ L4426-01 47 Co-57 9.70E-01 7.90E-01 2.602+00 STJ L4426-01 47 Co-58 -1.70E+00 1.20E+00 4.602+00 STJ L4426-01 47 Co-60 1.102+00 1.40E+00 4.702+00 STJ L4426-01 47 Cr-51 4.00E+00 1.202+01 4.002+01 STJ L4426-01 47 Cs-134 1. O10+00 1.40E+00 4.802+00 STJ L4426-01 47 Cs-137 1.002-01 1.30E+00 4.50E+00 STJ L4426-01 47 Fe-59 1.60E+00 2.90E+00 1.002+01 STJ L4426-01 47 GROSS BETA 4.60E+00 1.10E+00 3.00E+00 STJ L4426-01 47 1-131 8.002-02 2.00E-01 8.50E-01 STJ L4426-01 47 K-40 3.20E+0O 2.00E+01 6.50E+01 STJ L4426-01 47 La-140 -4.002-01 3.00E+00 1.102+01 STJ L4426-01 47 Mn-54 -2.20E+00 1.30E+00 5.002+00 STJ L4426-01 47 Nb-95 -8.00E-01 1.60E+00 5.90E+00 STJ L4426-01 47 Ru-103 -3.00E+00 1.20E+00 4.80E+00 STJ L4426-01 47 Ru-106 2.202+01 1.102+01 3.60E+01 STJ L4426-01 47 Sb-1 24 5.00E-01 3.50E+00 1.30E+01 STJ L4426-01 47 Sb-125 -3.70E+00 3.20E+00 1.20E+01 STJ L4426-01 47 Se-75 1.202+00 1.60E+00 5.402+00 STJ L4426-01 47 Zn-65 2.702+00 3.80E+00 1.302+01 STJ L4426-01 47 Zr-95 -1.402+00 2.10E+00 7.70E+00 LTW L4426-02 47 AcTh-228 -1.29E+01 5.00E+00 1.902+01 LTW L4426-02 47 Ag-108m 1.802+00 1.00E+00 3.30E+00 LTW L4426-02 47 Ag-llOm 2.002-01 1.70E+00 5.90E+00
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-182
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
LTW L4426-02 47 Ba-140 -1.90E+00 2.70E+00 1.OOE+01 LTW L4426-02 47 Be-7 1.30E+01 l. lOE+0O 3.50E+01 LTW L4426-02 47 Ce-141 -2.00E-01 1.70E+00 5.80E+00 LTW L4426-02 47 Ce-144 9.OOE+00 5.80E+00 1.90E+01 LTW L4426-02 47 Co-57 8.OOE-02 7.20E-01 2.50E+00 LTW L4426-02 47 Co-58 -1.40E+00 1.20E+00 4.70E+00 LTW L4426-02 47 Co-60 -1.OOE-01 1.30E+00 4.80E+00 LTW L4426-02 47 Cr-51 2.OOE+00 1.1OE+01 3.90E+01 LTW L4426-02 47 Cs-1 34 2.30E+00 1.20E+00 3.70E+OO LTW L4426-02 47 Cs-137 -8.OOE-01 1.20E+00 4.20E+00 LTW L4426-02 47 Fe-59 -3.80E+00 2.80E+00 1.tOE+01 LTW L4426-02 47 GROSS BETA 2.24E+00 9.70E-01 3.IOE+00 LTW L4426-02 47 1-131 6.20E-01 2.90E-01 7.60E-01 LTW L4426-02 47 K-40 -1.40E+01 2.OOE+0O 7.30E+01 LTW L4426-02 47 La-140 -2.20E+00 3.10E+00 1.20E+01 LTW L4426-02 47 Mn-54 3.20E+00 1.40E+00 4.40E+00 LTW L4426-02 47 Nb-95 1.OOE+00 1.40E+00 4.70E+00 LTW L4426-02 47 Ru-103 -1.1OE+00 1.30E+00 4.70E+00 LTW L4426-02 47 Ru-106 1.50E+01 1.1OE+01 3.50E+01 LTW L4426-02 47 Sb-124 1.50E+00 3.10E+00 l. 1OE+01 LTW L4426-02 47 Sb-125 -1.30E+00 2.90E+00 1.OOE+01 LTW L4426-02 47 Se-75 - 1.80E+00 1.40E+00 4.80E+00 LTW L4426-02 47 Zn-65 -3.30E+00 2.60E+00 9.80E+00 LTW L4426-02 47 Zr-95 -1.30E+00 2.1OE+00 7.70E+00 STJ L4503-01 49 AcTh-228 -1.20E+00 3.50E+00 1.30E+0I STJ L4503-01 49 Ag-108m -3.30E-0I 8.70E-01 3.20E+00 STJ L4503-01 49 Ag- lOnm -1 .82E+00 9.70E-01 4.40E+OO STJ L4503-01 49 Ba-140 2.60E+00 2.10E+00 7.OOE+00 STJ L4503-01 49 Be-7 -4.70E+00 8.50E+00 3.20E+01 STJ L4503-01 49 Ce-141 -2.70E+00 2.OOE+00 7.30E+00 STJ LA503-01 49 Ce-144 4.70E+00 6.20E+00 2.IOE+01 STJ L4503-01 49 Co-57 -9. lOE-01 8.90E-01 3.20E+00 STJ L4503-01 49 Co-58 1.51E+00 9.90E-01 3.20E+00 STJ L4503-01 49 Co-60 O.OOE+00 9.50E-O1 3.70E+00 STJ L4503-01 49 Cr-51 -3.OOE+00 . IlOE+01 3.90E+01 STJ L4503-01 49 Cs-134 6.OOE-01 l.lOE+00 3.90E+OO STJ L4503-01 49 Cs-137 5.00E-02 9.80E-01 3.60E+00 STJ L4503-01 49 Fe-59 -8.OOE-01 2.10E+O0 8.30E+00
- Radioactivity detected in sample (i.e, concentration > 3 X standard deviation)
D-183
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg). (pCi/lkg)
STJ L4503-01 49 GROSS BETA 2.60E+O0 1.1OE+O0 3.30E+OO STJ L4503-01 49 1-131 -1.OOE-02 1.60E-01 9.50E-O1 STJ L4503-01 49 K-40 -1.70E+01 1.40E+01 5.50E+O1 STJ L4503-01 49 La-140 3.00E+00 2.40E+00 8.10E+OO STJ L4503-01 49 Mn-54 2.60E-01 7.50E-01 2.80E+OO STJ . L4503-01 49 Nb-95 2.00E-O1 I. IOE+0O 4.20E+0O STJ L4503-01 49 Ru-103 -1.90E+OO I.IOE+OO 4.30E+OO STJ LA503-01 49 Ru-106 -8.00E+00 9.80E+00 3.80E+O1 STJ L4503-01 49 Sb-124 2.40E+00 2.50E+00 8.80E+O0 STJ L4503-01 49 Sb-125 -3.OOE+00 2.80E+O0 I.IOE+0O STJ L4503-01 49 Se-75 1.80E+OO I.IOE+OO 3.70E+0O STJ L4503-01 49 Zn-65 -1.90E+00 2.30E+00 9.00E+OO STJ LU503-01 49 Zr-95 -2.60E+00 1.70E+00 7.20E+0O LTW L4503-02 49 AcTh-228 -2. 10E+00 4.30E+00 1.60E+01 LTW L4503-02 49 Ag-108m 2.30E-01 9.40E-01 3.40E+OO LTW L4503-02 49 Ag-ll0m -1.40E+O0 I.IOE+0O 4.80E+O0 LTW L4503-02 49 Ba-140 2.20E+00 2.00E+00 7.10E+OO LTW L4503-02 49 Be-7 4.90E+00 8.70E+00 3.10E+O1 LTW L4503-02 49 Ce-141 -1.80E+00 2.10E+00 7.60E+OO LTW L4503-02 49 Cc-144 8.30E+00 7.60E+00 2.50E+OI LTW L4503-02 49 Co-57 -4.90E-01 9.10E-01 3.20E+0O LTW L4503-02 49 Co-58 -1.60E+OO 1.IOE+OO 4.40E+O0 LTW L4503-02 49 Co-60 1.67E+00 9.60E-01 3.10E+OO LTW L4503-02 49 Cr-51 8.001E+00 1.20E-+01 4.OOE+O1 LTW L4503-02 49 Cs-134 8.40E-01 9.10E-01 3.10E+OO LTW L4503-02 49 Cs-137 0.OOE+OO 1.lOE+OO 4.1OE+O0 LTW L4503-02 49 Fe-59 -1.70E+00 2.40E+00 9.60E+OO LTW L4503-02 49 GROSS BETA 1.17E+00 9.30E-01 3.101E+OO LTW L4503-02 49 1-131 1.70E-OI I.1OE-O1 3.50E-0I LTW L4503-02 49 K-40 -I.OOE+OO 1.40E+01 5.10E+OI LTW L4503-02 49 La-140 2.60E+00 2.40E+00 8.10E+O0 LTW L4503-02 49 Mn-54 -1.80E+O0 I.I1OE+OO 4.40E+OO LTW L4503-02 49 Nb-95 1.IOE+00 1.20E+00 4.30E+0O LTW L4503-02 49 Ru-103 2.00E-01 1.20E+00 4.30E+OO LTW L4503-02 49 Ru-106 -6.20E+00 9.50E+00 3.60E+OI LTW L4503-02 49 Sb-124 -9.OOE-01 3.40E+00 1.30E+O1 LTW UA503-02 49 Sb-125 1.40E+00 2.90E+0O 1.OOE+OI LTW L4503-02 49 Se-75 1.30E1+00 1.50E+00 5.20E+00 LTW LA503-02 49 Zn-65 -5.70E+00 2.80E+OO I. IOE+0O LTW L4503-02 49 Zr-95 -1.90E+00 1.70E+00 7.10E+OO
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-184
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
STJ L4579-01 AcTh-228 9.202+O00 6.20E+00 2.001E+01 STJ L4579-01 Ag-108m -3.001E-01 I1.20E+00 4.10OE-e00 STJ L4579-01 Ag-110m -3.001E+00 2.OOE+O0 7.70E+O00 STJ L4579-01 Ba-140 0.OO3+O00 3.OOE+00 1.1OE+01 STJ LA579-01 Be-7 I1.50E-i.01 I1.20E+01 3.901E+01 STJ L4579-01 Ce-141 -2.001E-01 2.20E+O0 7.601E+00 STJ L4579-01 Ce-144 5.30E3+00 7.30E+00 2.50oE+01 STJ L4579-01 Co-57 5.20E-01 9.80E-01 3.301E+00 STJ L4579-01 Co-58 -2.30E+O0 1.40E+O0 5.401E+00 STJ L4579-01 Co-60 -1.OOE-01 I1.40E+00 5.101E-g0O STJ L4579-01 Cr-51 -2.OOE+00 I1.40E+01 5.OOE+01 STJ L4579-01 Cs- 134 3.301E+00 1.50E+O0 STJ LA579-01 Cs-137 6.OOE-01 1.40E+00 4.80E1i-00 STJ L4579-01 Fe-59 1.60E-i00 2.80E1i-00 1.OOE+01 STJ L4579-01 GROSS BETA 6.101E+00 1.20E+O0 3.IOE3+00 STJ LA579-01 1-131 6.OOE-01 3.30E-01 8.50E-01 STJ LA579-01 K-40 -1.80E+01 1.80E+01 6.90E+01 STJ LA579-01 La-140 0.OOE+00 3.40E3+00 I1.30E+01 STJ LA579-01 Mn-54 -1.40E+00 1.50E+O0 5.60E+O0 STJ L4579-01 Nb-95 -2.50E+00 1.60E+00 6.40E3+00 STJ L4579-01 Ru-103 -9.001E-01 I1.50E+O0 5.50E3+00 STJ L4579-01 Ru-106 -1.30E+01 I1.30E+01 4.701E+01 STJ L4579-01 Sb-124 1.90E-i00 3.70E+O0 I1.301E+01 STJ 14579-01 Sb-125 6.OOE-01 3.60Et-00 1.30E3+01 STJ L4579-01 Se-75 1.1OE+00 I1.801E+00 6. 101+00 STJ L4579-01 Zn-65 -4.30E+00 3.OOEi-00 I1.20E3+01 STJ L4579-01 Zr-95 1.60E+00 2.10OE+00 7.30E,-00 LTW L4579-02 AcTh-228 4.60E+O0 I1.70E3+01 LTW L4579-02 Ag-108m -1.33E+00 9.60E-01 3.50E+O00 LTW LA579-02 Ag-1 10m -9.OOE-01 1.60E+00 5.70E+O00 LTW L4579-02 Ba-140 3.50E+O0 2.30E+00 7.50E+O00 LTW I.4579-02 Be-7 -7.001E-01 9.90E-,00 3.501E+01 LTW 1A579-02 Ce-141 -4.801E+00 3.1OE+00 1.IOE+01 LTW L4579-02 Ce-144 -5.70E+O0 6.50E+O0 2.301E+01 LTW L4579-02 Co-57 5.10OE-01 8.80E-01 2.90E-,00 LTW L4579-02 Co-58 1.402+O00 I. IOE+00 3.701E+00 LTW LA579-02 Co-60 -I1.60E+00 1.30Ei-00 4.903+O00 LTW LA579-02 Cr-51 -1.70E+01 L1.OE+01 4.001E+01
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-185
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
LTW L4579-02 51 Cs-134 -1.30E+00 1.30E+00 4.70E+00 LTW L4579-02 51 Cs-137 2.OOE-01 1. lOE+00 3.80E+00 LTW LA579-02 51 Fe-59 1.90E+00 2.50E+00 8.70E+00 LTW L4579-02 51 GROSS BETA 3.32E+00 9.70E-01 2.80E+00 * -
LTW L4579-02 51 1-13 -1.242-01 2.60E-02 8.20E-0O LTW L4579-02 51 K-40 -4.00E3+00 1.70E+01 5.90E+0O LTW L4579-02 51 La-140 4.OOE+00 2.60E+00 8.60E+00 LTW L4579-02 51 Mn-54 9.00E-01 1.1 OE+00 3.70E+00 LTW L4579-02 51 Nb-95 -1.50E+00 2.00E+00 7.10E+00 LTW L4579-02 51 Ru-103 9.00E-01 1.302+00 4.40E+00 LTW L4579-02 51 Ru-106 -8.00E+00 l.00O+01 3.70E+I01 LTW L4579-02 51 Sb-124 -2.20E+00 2.90E+00 1.1OE+01 LTW UA579-02 51 Sb-125 3.40E+00 3.10E+00 1.002+01 LTW L4579-02 51 Se-75 7.00E-01 1.40E+00 4.80E+00 LTW L4579-02 51 Zn-65 -6.50E+00 2.90E+00 1.10+01I LTW L4579-02 51 Zr-95 -2.00E+00 2.00E+00 7.30E+00 STI L2874-01 Ql H-3 5.00E+01 4.30E+02 1.30E+03 LTW L2874-02 Ql H-3 2.30E+02 4.402+02 1.302+03 STJ L3586-01 Q2 H-3 -1.00O+02 4.102+02 1.202+03 LTW L3586-02 Q2 H-3 7.00E+02 4.20E+02 1.20E+03 STJ L4291-01 Q3 H-3 2.10E+02 2.80E+02 9.00E+02 LTW L4291-02 Q3 H-3 1.80E+02 2.80E+02 8.90E+02 STJ L4881-01 Q4 H-3 2.70E+02 4.20E+02 1.302+03 LTW L4881-02 Q4 H-3 -1.60E+02 4.20E+02 1.30E+03
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-186
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
WG W-1 L2173-01 04 AcTh-228 2.10E+00 3.60E+00 1.20E+01 W.l L2173-01 04 Ag-108m 2.10E-01 5.80E-01 2.OOE+00 W-1 L2173-01 04 Ag-I blm 1.94E+00 9.50E-01 3.10E+00 W-l L2173-01 04 Ba-140 -I.OOE+00 2.10E+00 7.50E+00 W-l L2173-01 04 Be-7 4.20E+00 6.50E+00 2.20E+01 W-l L2173-01 04 Ce-141 1.80E+00 1.80E+00 6.10E+00 W-l L2173-01 04 Ce-144 8.30E+00 3.70E+00 1.20E+0O W-l L2173-01 04 Co-57 -1.90E-01 4.70E-01 1.60E+00 W-l L2173-01 04 Co-58 -1.23E+00 7.40E-01 2.70E+00 W-l L2173-01 04 Co-60 1.85E+00 7.80E-01 2.50E+00 W-l L2173-01 04 Cr-51 1.OOE+01 8.90E+00 3.OOE+0O W-l L2173-01 04 Cs-134 9.70E-01 6.90E-01 2.30E+00 W-l L2173-01 04 Cs-137 -1.19E+00 7.30E-01 2.60E+00 W-l L2173-01 04 Fe-59 -3.OOE+00 2.50E+00 8.90E+00 W-I L2173-01 04 H-3 2.60E+02 3.70E+02 I.I0E+03 W-l L2173-01 04 1-131 3.50E+00 4.20E+00 1.40E+0I W-l L2173-01 04 K-40 -1.60E+01 1.30E+01 4.40E+0O W-l L2173-01 04 La-140 -1.IOE+00 2.40E+00 8.60E+00 W-l L2173-01 04 Mn-54 -8.10E-01 6.30E-01 2.30E+00 W-l L2173-01 04 Nb-95 1.68E+00 9.80E-01 3.20E+00 W-l L2173-01 04 Ru-103 -1.04E+00 9.OOE-01 3.20E+00 W-I L2173-01 04 Ru-106 -1.23E+01 6.90E+00 2.40E+0O W-l L2173-01 04 Sb-124 -5.00E-01 1.80E+00 6.50E+00 W-I L2173-01 04 Sb-125 -1.40E+00 1.80E+00 I.IOE+01 W-1 L2173-01 04 Se-75 1.60E-01 7.80E-01 2.60E+00 W-l L2173-01 04 Zn-65 2.30E+00 2.OOE+00 6.40E+00 W-l L2173-01 04 Zr-95 3.OOE-01 1.40E+00 4.80E+00 W-2 L2173-02 04 AcTh-228 -6.90E+00 4.10E+00 1.50E+0O W-2 L2173-02 04 Ag-108m -1.59E+00 7.60E-01 2.80E+00 W-2 L2173-02 04 Ag-I lOm 1.70E+00 1.30E+00 4.40E+00 W-2 L2173-02 04 Ba-140 -2.40E+00 2.20E+00 8.40E+00 W-2 L2173-02 04 Be-7 5.30E+00 8.60E+00 2.90E+01 W-2 L2173-02 04 Ce-141 O.OOE+00 1.50E+00 5.OOE+00 W-2 L2173-02 04 Ce-144 -5.00E+00 5.OOE+00 1.70E+0O W-2 L2173-02 04 Co-57 -3.OOE-01 5.90E-01 2.OOE+00 W-2 L2173-02 04 Co-58 7.60E-01 9.50E-01 3.20E+00 W-2 L2173-02 04 Co60 2.OOE-02 9.OOE-01 3.20E+00 W-2 L2173-02 04 Cr-51 Q.OOE+00 I.IOE+01 3.70E+01 W-2 L2173-02 04 Cs-134 2.10E-01 9.40E-01 3.30E+O0
- Radioactivity detected insample (i.e., concentration > 3 X standard deviation)
D-187
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
W-2 L2173-02 04 Cs-137 6.20E-01 9.OOE-01 3.10E+00 W-2 L2173-02 04 Fe-59 9.OOE-01 2.80E+00 9.70E+00 W-2 L2173-02 04 H-3 1.70E+02 3.60E+02 I.IOE+03 W-2 L2173-02 04 1-131 2.OOE+00 4.20E+00 1.40E+01 W-2 L2173-02 04 K-40 -7.OOE+0O 1.50E+01 5.30E+01 W-2 L2173-02 04 La-140 -2.80E+00 2.50E+00 9.70E+00 W-2 L2173-02 04 Mn-54 -2.50E-01 7.90E-01 2.80E+00 W-2 L2173-02 04 Nb-95 8.OOE-01 1.20E+00 4.OOE+00 W-2 L2173-02 04 Ru-103 -1.60E+00 1.1OE+00 4.OOE+00 W-2 L2173-02 04 Ru-106 1.60E+00 8.70E+00 3.00E+OI W-2 L2173-02 04 Sb-124 3.OOE-01 2.40E+00 8.50E+OO W-2 L2173-02 04 Sb-125 -6.70E+00 2.30E+00 8.60E+00 W-2 L2173-02 04 Se-75 -5.00E-01 I.OOE+OO 3.60E+00 W-2 L2173-02 04 Zn-65 2.00E-01 2.70E+00 9.50E+00 W-2 L2173-02 04 Zr-95 -9.00E-01 1.80E+00 6.50E+OO W-3 L2173-03 04 AcTh-228 4.OOE+00 4.50E+00 1.50E+01 W-3 L2173-03 04 Ag-108m 6.30E-01 6.70E-01 2.30E+00 W-3 L2173-03 04 Ag-ll0m -5.OOE-01 I.1OE+00 3.90E+00 W-3 L2173-03 04 Ba-140 -2.OOE-01 2.30E+00 8.40E+00 W-3 L2173-03 04 Be-7 8.00E-01 7.90E+00 2.70E+01 W-3 L2173-03 04 Cc-141 2.OOE-01 2.30E+00 7.80E+00 W-3 L2173-03 04 Ce-144 6.OOE-01 4.90E+00 1.60E+01 W-3 L2173-03 04 Co-57 -4.OOE-01 6.20E-01 2.10E+00 W-i L2173-03 04 Co-58 9.20E-01 9.40E-01 3.20E+00 W-3 L2173-03 04 Co-60 1.IIE+00 8.60E-01 2.90E+00 W-3 L2173-03 04 Cr-51 5.OOE+00 I.IOE+01 3.60E+01 W-3 L2173-03 04 Cs-134 6.50E-01 8.80E-01 3.OOE+00 W-3 L2173-03 04 Cs-137 -2.40E-01 9.10E-01 3.20E+00 W-3 L2173-03 04 Fe-59 2.20E+00 2.50E+00 8.50E+00 W-3 L2173-03 04 H-3 -3.70E+02 3.60E+02 1.IOE+03 W-3 L2173-03 04 1-131 -5.60E+00 4.40E+00 1.50E+0O W-3 L2173-03 04 K-40 8.OOE+00 1.40E+01 4.70E+01 W-3' L2173-03 04 La-140 -3.OOE-01 2.70E+00 9.60E+00 W-3 L2173-03 04 Mn-54 2.10E-01 8.40E-01 2.90E+OO W-3 L2173-03 04 Nb-95 -I.OOE+00 1.30E+00 4.60E+00 W-3 L2173-03 04 Ru-103 -8.OOE-0I 1.10E+00 3.70E+00 W-3 L2173-03 04 Ru-106 -1.1IE+0 8.IOE+00 2.90E+01 W-3 L2173-03 04 Sb-124 5.00E-01 2.40E+00 8.50E+00 W-3 L2173-03 04 Sb-125 1.70E+00 2.10E+00 7.20E+00 W-3 L2173-03 04 Se-75 -1.OOE-01 l.IOE+00 3.90E+00
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-188
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
W-3 L2173-03 04 Zn-65 8.20E+00 3.50E+00 1.lOE+01 W-3 L2173-03 04 Zr-95 -8.OOE-01 1.50E+00 5.30E+00 W-4 L2173-04 04 AcTh-228 2.70E+00 4.70E+00 1.60E+O I W-4 L2173-04 04 Ag-108m -3.50E-01 9.90E-01 3.50E+00 W-4 L2173-04 04 Ag-lOnm 1.IOE+00 1.80E+00 6.20E+00 W4 L2173-04 04 Ba-140 6.70E+00 2.90E+00 8.80E+00 W4 L2173-04 04 Be-7 -1.20E+O1 1.IOE+01 4.00E+0l W4 L2173-04 04 Ce-141 2.30E+00 2.90E+00 9.80E+00 W4 L2173-04 04 Ce-144 9.10E01+00 6.40E+00 2AOE+0l W4 L2173-04 04 Co-57 -8.20E-01 8.50E-01 3.OOE+00 W4 L2173-04 04 Co-58 1.20E+00 1.20E+00 4.00E+00 W4 L2173-04 04 Co-60 2.60E+00 1.20E+00 3.80E+00 W4 L2173-04 04 Cr-51 -3.40E+01 1.40E+01 5.OOE+01 W4 L2173-04 04 Cs-134 8.OOE-01 1.30E+00 4.30E+00 WA4 L2173-04 04 Cs-137 -4.OOE-01 1.30E+00 4.60E+00 W4 L2173-04 04 Fe-59 I.OOE+00 3.70E+00 1.30E+01 W4 L2173-04 04 H-3 5.OOE+02 3.70E+02 1.IOE+03 W4 L2173-04 04 1-131 -2.40E+00 4.70E+00 1.60E+01 W4 L2173-04 04 K-40 -9.OOE+00 1.80E+01 6.40E+01 W4 L2173-04 04 La-140 7.70E+00 3.30E+00 l.OOE+01 W4 L2173-04 04 Mn-54 3.00E-01 1.20E+00 4.10E+00 W4 L2173-04 04 Nb-95 -3.20E+00 1.70E+00 6.20E+00 W4 L2173-04 04 Ru-103 2.OOE-01 1.40E+00 4.90E+00 W4 L2173-04 04 Ru-106 -1.20E+0 LIlOE+01 4.OOE+01 W4 L2173-04 04 Sb-124 -4.00E-01 3.90E+00 1.40E+01 W4 L2173-04 04 Sb-125 -2.80E+00 3.OOE+00 1.10E+01 WA4 L2173-04 04 Se-75 -2.1OE+00 1.60E+00 5.60E+00 W4 L2173-04 04 Zn-65 5.OOE-01 3.30E+00 1.lOE+01 W-4 L2173-04 04 Zr-95 -5.OOE-01 2.OOE+00 7.10E+00 W-5 L2173-05 04 Acrb-228 7.50E+00 3.50E+00 l.lOE+01 W-5 L2173-05 04 Ag-108m -1.38E+00 8.20E-01 3.OOE+00 W-5 L2173-05 04 Ag-l1Orm I.OOE-01 1.30E+00 4.50E+00 W-5 L2173-05 04 Ba-140 -4.20E+00 2.70E+00 1.OOE+01 W-5 L2173-05 04 Be-7 -4.50E+00 8.70E+00 3.10E+01 W-5 L2173-05 04 Ce-141 3.OOE+00 1.80E+00 5.80E+00 W-5 L2173-05 04 Ce-144 1.90E+00 5.50E+00 I.90E+OI W-5 L2173-05 04 Co-57 5.00E-02 6.80E-01 2.30E+00 W-5 L2173-05 04 Co-58 -6.70E-01 9.60E-01 3.50E+00 W-5 L2173-05 04 Co-60 8.40E-01 9.90E-01 3.40E+00 W-5 L2173-05 04 Cr-51 -I.IOE+01 1.20E+01 4.00E+I01
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-189
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
W-5 L2173-05 04 Cs-134 4.80E-01 9.90E-01 3.40E+00 W-5 L2173-05 04 Cs-137 -7.OOE-01 1.OOE+00 3.60E+00 W-5 L2173-05 04 Fe-59 -3.00E-01 3.20E+00 1.102+01 W-5 L2173-05 04 H-3 2.40E+02 3.30E+02 l.OOE+03 W-5 L2173-05 04 1-131 1.60E+00 4.40E+00 1.502+01 W-5 L2173-05 04 K-40 1.17E+02 1.90E+01 5.60E+01 W-5 L2173-05 04 La-140 -4.90E+00 3.20E+00 1.20E+01 W-5 L2173-05 04 Mn-54 -I.OOE-01 1.OOE+00 3.50E+00 W-5 L2173-05 04 Nb-95 -5.00E+00 1.50E+00 5.80E+00 W-5 L2173-05 04 Ru-103 -9.OOE-01 1.20E+00 4.20E+00 W-5 L2173-05 04 Ru-106 l.OOE-01 9.20E+00 3.20E+01 W-5 L2173-05 04 Sb-124 2.70E+00 2.60E+00 8.80E+00 W-S L2173-05 04 Sb-125 -9.OOE-01 2.60E+00. 9.00E+00 w-s L2173-05 04 Se-75 -6.00E-01 1.30E+00 4.40E+00 W-5 L2173-05 04 Zn-65 -7.OOE-01 2.00E+00 7.10E+00 W-5 L2173-05 04 Zr-95 6.00E-01 1.80E+00 6.30E+00 W-6 L2173-06 04 AcTh-228 -2.00E+00 4.00E+00 1.40E+01 W-6 L2173-06 04 Ag-108m -1.01+00 7.80E-01 2.80E+00 W-6 L2173-06 04 Ag-ll0m 1.00E-01 1.30E+00 4.70E+00 W-6 L2173-06 04 Ba-140 -1. 4 0Et+O 2.70E+00 9.70E+00 W-6 L2173-06 04 Be-7 -4.80E+00 8.70E+00 3.10E+01 W-6 L2173-06 04 Ce-141 1.20E+00 1.60E+00 5.20E+00 W-6 L2173-06 04 Ce-144 3.90E+00 5.50E+00 1.80E+01 W-6 L2173-06 04 Co-57 1.67E+00 7.30E-01 2.40E+00 W-6 L2173-06 04 Co-58 -1.40E+00 1.10E+00 4.00E+00 W-6 L2173-06 04 Co-60 2.40E-01 9.502-01 3.40E+00 W-6 L2173-06 04 Cr-51 1.10E+01 1.10+01 3.80E+01 W-6 L2173-06 04 Cs-134 -6.20E-01 9.90E-01 3.60E+00 W-6 L2173-06 04 Cs-137 1.20E+00 1.lOE+00 3.50E+00 W-6 L2173-06 04 Fe-59 -9.002-01 2.80E+00 l.OOE+01 W-6 L2173-06 04 H-3 6.40E+02 3.70E+02 1.10E+03 W-6 L2173-06 04 1-131 3.50E+00 4.30E+00 1.50E+01 W-6 L2173-06 04 K-40 3.10E+01 1.60E+01 5.10E+01 W-6 L2173-06 04 La-140 -1.60E+00 3.10E+00 1.10E+01 W-6 L2173-06 04 Mn-54 9.80E-01 9.60E-01 3.20E+00 W-6 L2173-06 04 Nb-95 -1.20E+00 1.40E+00 4.90E+00 W-6 L2173-06 04 Ru-103 -2.70E+00 1.20E+00 4.40E+00 W-6 L2173-06 04 Ru-106 1.94E+01 8.90E+00 2.90E+01 W-6 L2173-06 04 Sb-124 1.90E+00 2.80E+00 9.502+00 W-6 L2173-06 04 Sb-125 -1.1OE+00 2.50E+00 8.80E+00
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D- 190
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
W-6 L2173-06 04 Se-75 2. 10E+00 1.30E+O0 4.20E+00 W-6 L2173-06 04 Zn-65 l.OOE+00 2.40E+0O 8.20E+O0 W-6 L2173-06 04 Zr-95 3.OOE+00 1.80E+OO 5.90E3+00 W-7 L2173-07 04 AcTh-228 -4.60E+00 5.10E+O0 1.80E+OI W-7 L2173-07 04 Ag-108m -2.08E+O0 9.50E-O1 3.60E+00 W-7 L2173-07 04 Ag-l1Om 1.80E+00 1.60E+00 5.50E+00 W-7 L2173-07 04 Ba-140 -3.OOE+O0 3. 1OE+00 1.20E+OI W-7 L2173-07 04 Be-7 l.OOE+O0 l.OOE+01 3.70E+O1 W-7 L2173-07 04 Ce-141 -2.OOE-01 2.20E+00 7.60E+O0 W-7 L2173-07 04 Ce-144 -9.30E+00 6.40E+00 2.30E+O1 W-7 L2173-07 04 Co-57 -1.73E+00 8.10E-0O 2.90E+00 W-7 L2173-07 04 Co-58 l.OOE+00 1.20E+00 4.00E+00 W-7 L2173-07 04 Co-60 -1.40E+00 1.30E+O0 4.80E+00 W-7 L2173-07 04 Cr-51 8.OOE+00 1.40E+0O 4.70E+0O W-7 L2173-07 04 Cs-134 9.OOE-01 1.20E+O0 4.10E+00 W-7 L2173-07 04 Cs-137 -6.OOE-01 1.20E+00 4.20E+00 W-7 L2173-07 04 Fe-59 1.50E+00 3.70E+00 1.30E+OI W-7 L2173-07 04 H-3 -6.70E+02 3.50E+02 1.20E+03 W-7 L2173-07 04 1-131 -9.30E+00 5.60E+00 2.10E+0O W-7 L2173-07 04 K-40 -2.OOE+00 1.80E+01 6.50E+01 W-7 L2173-07 04 La-140 -3.50E+00 3.60E+00 1.40E+0O W-7 L2173-07 04 Mn-54 1.40E+00 l.OOE+00 3.50E+00 W-7 L2173-07 04 Nb-95 -I. IOE+00 1.50E+00 5.50E+O0 W-7 L2173-07 04 Ru-103 -2.70E+OO 1.50E+00 5.70E+00 W-7 L2173-07 04 Ru-106 2.OOE+00 l.lOE+01 3.90E+0O W-7 L2173-07 04 Sb-124 6.80E+00 3.10E+00 9.40E+00 W-7 L2173-07 04 Sb-125 -5.90E+O0 2.90E+00 1.1OE+01 W-7 L2173-07 04 Se-75 8.OOE-01 1.30E+00 4.40E+00 W-7 L2173-07 04 Zn-65 -6.OOE-0O 2.80E+00 l.OOE+0O W-7 L2173-07 04 Zr-95 6.OOE-0O 2.30E+00 8.10E+00 W-8 L2173-08 04 AcTb-228 -9.OOE-0O 3.90E+O0 1.30E+01 W-8 L2173-08 04 Ag-108m 6.70E-01 6.20E-OI 2. 10E+O0 W-8 L2173-08 04 Ag-l1lm 1.37E+O0 9.90E-01 3.30E+O0 W-8 L2173-08 04 Ba-140 2.30E+00 2.30E+00 7.90E+00 W-8 L2173-08 04 Be-7 -1.31E+O1 7.20E+00 2.60E+0O W-8 L2173-08 04 Ce-141 6.OOE-0O 1.40E+0O 4.70E+00 W-8 L2173-08 04 Ce-144 2.20E+00 4.20E+O0 1.40E+OI W-8 L2173-08 04 Co-57 5.30E-0O 5.60E-0O 1.80E+00 W-8 L2173-08 04 Co-58 -3.OOE-0O 7.90E-0O 2.80E+00 W-8 L2173-08 04 Co-60 9.1OE-0I 7.60E-0O 2.50E+00
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-191
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
W-8 L2173-08 04 Cr-SI 1.14E+01 9.40E+00 3.102+01 W-8 L2173-08 04 Cs-134 4.20E-01 7.40E-01 2.50E+00 W-8 L2173-08 04 Cs-137 -2.05E+00 8.00E-01 2.90E+00 W-8 L2173-08 04 Fe-59 -5.40E+00 2.50E+00 9.302+00 W-8 L2173-08 04 H-3 -6.OOE+01 3.60E+02 1.102+03 W-8 L2173-08 04 1-131 -6.70E+00 4.00E+00 1.40E+01 W-8 L2173-08 04 K-40 1.30E+I01 1.30E+01 4.502+01 W-8 L2173-08 04 La-140 2.70E+00 2.70E+00 9.10E+00 W-8 L2173-08 04 Mn-54 4.90E-01 7.70E-01 2.602+00 W-8 L2173-08 04 Nb-95 -3.40E+00 1.40E+00 4.90E+00 W-8 L2173-08 04 Ru-103 -3. 10E+00 9.60E-01 3.50E+00 W-8 L2173-08 04 Ru-106 1.39E+01 7.00E+00 2.30E+01 W-8 L2173-08 04 Sb-124 -2.30E+00 2.10E+00 7.80E+00 W-8 L2173-08 04 Sb-125 5.002-01 1.90E+00 6.402+00 W-8 L2173-08 04 Se-75 -1.OOE-01 1.00O+00 3.50E+00 W-8 L2173-08 04 Zn-65 -8.OOE-01 1.60E+00 5.70E+00 W-8 L2173-08 04 Zr-95 1.501E+00 1.40E+00 4.60E+00 W-9 L2173-09 04 Acih-228 4.40E+00 2.50E+00 8.30E+00 W-9 L2173-09 04 Ag-108m 3.40E-01 5.50E-01 1.902+00 W-9 L2173-09 04 Ag- lOnm 3.50E-01 9.40E-01 3.20E+00 W-9 L2173-09 04 Ba-140 -1.90E+00 2.00E+00 7.302+00 W-9 L2173-09 04 Be-7 -1.90E+00 6.40E+00 2.202+01 W-9 L2173-09 04 Ce- 141 2.80E+00 1.20E+00 4.00E+00 W-9 L2173-09 04 Ce-144 2.10E+00 3.70E+00 1.20E+01 W-9 L2173-09 04 Co-57 7.40E-01 4.70E-01 1.60E+00 W-9 L2173-09 04 Co-58 -4.80E-01 6.70E-01 2.402+00 W-9 L2173-09 04 Co-60 -6.90E-01 7.60E-01 2.70E+00 W-9 L2173-09 04 Cr-51 -1.20E+01 8.60E+00 3.00E+01 W-9 L2173-09 04 Cs-134 3.40E-01 6.80E-01 2.302+00 W-9 L2173-09 04 Cs-137 -1.90E-01 7.40E-01 2.60E+00 W-9 L2173-09 04 Fe-59 6.00E-01 2.20E+00 7.70E+00 W-9 L2173-09 04 H-3 -8.00E+01 3.60E+02 1.IOE+03 W-9 L2173-09 04 I-131 -8.00E-01 3.60E+00 1.20E+01 W-9 L2173-09 04 K-40 -2.00E+00 1.30E+01 4.402+01 W-9 L2173-09 04 La-140 -2.20E+00 2.30E+00 8.40E+00 W-9 L2173-09 04 Mn-54 -7.20E-01 6.102-01 2.20E+00 W-9 L2173-09 04 Nb-95 4.00E-02 9.30E-01 3.20E+00 W-9 L2173-09 04 Ru-103 -5.90E-01 8.80E-01 3.10E+00 W-9 L2173-09 04 Ru-106 1.20E+00 6.50E+00 2.20E+01 W-9 L2173-09 04 Sb-124 2.00E-01 1.90E+00 6.80E+00
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-192
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
W.9 L2173-09 04 Sb-125 -2.60E+00 1.70E+00 6.OOE+00 W-9 L2173-09 04 Se-75 5.60E-01 7.70E-0I 2.60E+00 W-9 L2173-09 04 Zn-65 l.OOE-0O 1.40E+00 4.90E+00 W-9 L2173-09 04 Zr-95 2.60E+00 1.30E+00 4.30E+00 w-10 L2173-10 04 AcTh-228 3.50E+00 4.20E+00 1.40E+01 w-10 L2173-10 04 Ag- 108m -3.70E-0O 7.30E-01 2.SOE+00 w-10 L2173-10 04 Ag-I lOm 2.10E+00 1.30E+00 4.30E+00 w-10 L2173-10 04 Ba- 140 3.OOE-01 3.10E+00 1.1OE+01 w-10 L2173-10 04 Be-7 1.44E+01 8.50E+00 2.80E+01 W-10 L2173-10 04 Ce-141 -2.70E+00 2.50E+00 8.60E+00 w-1o L2173-10 04 Ce-144 2.OOE+00 4.60E+00 1.50E+01 w-10 L2173-10 04 Co-57 3.30E-01 5.80E-01 1.90E+00 w-1o L2173-10 04 Co-58 9.OOE-01 l.OOE+00 3.40E+00 w-10 L2173-10 04 Co-60 -8.OOE-01 l.OOE+00 3.70E+00 w-10 L2173-10 04 Cr-51 -6.OOE+00 1.lOE+01 3.80E+0O w-10 L2173-10 04 Cs-134 -2.60E+00 1.lOE+00 4.OOE+00 w-l0 L2173-10 04 Cs-137 -3.30E-01 9.90E-01 3.40E+00 w-10 L2173-10 04 Fe-59 -5.20E+00 3.10E+00 1.20E+01 w-10 L2173-10 04 H-3 6.OOE+0O 3.60E+02 1.lOE+03 w-10 L2173-10 04 1-131 5.30E+00 5.IOE+00 1.70E+01 w-10 L2173-10 04 K-40 8.OOE+00 1.60E+01 5.60E+0O w-10 L2173-10 04 La-140 4.OOE-01 3.60E+0O 1.30E+0O w-10 L2173-10 04 Mn-54 O.OOE+00 9.30E-01 3.20E+00 w-l0 L2173-10 04 Nb-95 -I.OOE+00 1.20E+00 4.40E+00 w-1o L2173-10 04 Ru-103 -3.OOE-0I 1.20E+00 4.OOE+00 w-10 L2173-10 04 Ru-106 -7.80E+00 8.10E+00 2.90E+0O W-10 L2173-10 04 Sb-124 3.60E+00 2.90E+00 9.90E+00 w-10 L2173-10 04 Sb-125 -8.OOE-01 2.30E+00 8.OOE+00 W-10 L2173-10 04 Se-75 1.20E+00 1.lOE+00 3.80E+00 W-10 L2173-10 04 Zn-65 5.20E+00 4.90E+00 1.60E+01 w-lo L2173-10 04 Zr-95 -4.OOE-01 1.60E+00 5.70E+00 w-1I L2173-11 04 AcTh-228 1.14E+01 3.80E+00 1.20E+01 w-1l L2173-11 04 Ag-108m -1.15E+00 8.70E-01 3.20E+00 w-1I L2173-11 04 Ag-i lOin 4. IOE+00 l.50E+00 4.50E+00 w-1j L2173-11 04 Ba-140 -1.90E+00 3.30E+00 1.20E+0O w-.I L2173-11 04 Be-7 8.OOE+00 1.OOE+01 3.50E+01 w-I L2173-11 04 Ce-141 3.60E+00 2.O0E+00 6.60E+00 w-I L2173-11 04 Ce-144 3.70E+00 5.80E+00 2.00E+01 w-1I L2173-11 04 Co-57 7.30E-01 7.60E-01 2.50E+00 W-1I L2173-11 04 Co-58 -8.OOE-01 l.lOE+00 4.20E+00
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-193
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg) w-1I L2173-11 04 Co-60 -2.00E-01 1.10E+00 4.002+00 w-11 L2173-11 04 Cr-51 -4.002+00 1.30E+01 4.40E+01 w-1I L2173-11 04 Cs-134 7.00E-01 1.OOE+00 3.50E+00 w-1I L2173-11 04 Cs-137 -2.60E+00 1. 1OE+00 4.20E+00 w.11 L2173-11 04 Fe-59 4.80E+00 3.60E+00 1.202+01 w-11 L2173-1 1 04 H-3 3.00E+01 3.70E+02 1.20E+03 w-1j L2173-11 04 1-131 1.30E3+00 5.50E+00 1.90E+01 w-11 L2173-11 04 K-40 6.00E+00 1.70E+01 5.802+01 w-1 L2173-11 04 La-140 -2.20E+00 3.80E+00 1.40E+01 w-11 L2173-11 04 Mn-54 2.10E+00 1.E10+00 3.60E+00 w-11 L2173-11 04 Nb-95 -3.002-01 1.302+00 4.60E+00 w-11 L2173-11 04 Ru-103 -8.OOE-01 1.30E+00 4.70E+00 w-11 L2173-11 04 Ru-106 1.OOE+01 1.002+01 3.50E+01 w-11 L2173-1 1 04 Sb-124 -7.00E-01 2.402+00 9.102+00 w-Il L2173-11 04 Sb-125 4.OOE-01 2.80E+00 9.70E+00 w-1l L2173-11 04 Se-75 -1.00-01 1.40E+00 4.70E+00 w-11 L2173-11 04 Zn-65 -3. IOE+00 2.30E+00 8.60E+00 w-11 L2173-11 04 Zr-95 2.60E+00 1.80E+00 5.90E+00 W-12 L2173-12 04 Acnh-228 8.80E+00 4.30E+00 1.402+01 W-12 L2173-12 04 Ag-108m -9.40E-01 8.602-01 3.102+00 W-12 L2173-12 04 Ag-l lOIm 2.40E+00 1.30E+00 4.30E+00 W-12 L2173-12 04 Ba-140 -3.30E+00 3.202+00 1.202+01 W-12 L2173-12 04 Be-7 1.10E+01 l.OOE+01 3.40E+01 W-12 L2173-12 04 Ce-141 1.IOE+00 2.50E+00 8.302+00 W-12 L2173-12 04 Ce-144 -2.50E+00 5.90E+00 2.00E+01 W-12 L2173-12 04 Co-57 -I .IOE+00 7.90E-01 2.802+00 W-12 L2173-12 04 Co-58 -3.00-01 1.20E+00 4.30E+00 W-12 L2173-12 04 Co-60 2.30E-01 9.80E-01 3.50E+00 W-12 L2173-12 04 Cr-51 -1.90E+01 1.30E+01 4.60E+01 W-12 L2173-12 04 Cs-134 1.00l2-01 1.102+00 3.90E+00 W-12 L2173-12 04 Cs-137 l.OOE-01 1.10E+00 3.802+00 W-12 L2173-12 04 Fe-59 -3.90E+00 3.202+00 1.20E+01 W-12 L2173-12 04 H-3 2.90E+02 3.90E+02 1.202+03 W-12 L2173-12 04 1-131 -6.80E+00 5.50E+00 2.002+01 W-12 L2173-12 04 K-40 -1.60E+01 1.70E+01 6.00E+01 W-12 L2173-12 04 La- 140 -3.80E+00 3.602+00 1.40E+01 W-12 L2173-12 04 Mn-54 -9.OOE-01 1.00E+00 3.80E+00 W-12 L2173-12 04 Nb-95 -4.10OE+00 1.50E+00 5.90E+00 W-12 L2173-12 04 Ru-103 -1.90E+00 1.30E+00 4.70E+00 W-12 L2173-12 04 Ru-106 -3.00E+00 1.1OE+01 3.80E+01
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-194
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
W-12 L2173-12 04 Sb-124 -1.1OE+00 2.90E+00 1.1OE+01 W-12 L2173-12 04 Sb-125 -2.OOE+00 2.80E+00 9.90E+00 W-12 L2173-12 04 Se-75 1.20E+00 1.40E+00 4.70E+00 W-12 L2173-12 04 Zn-65 -3.50E+00 2.70E+00 9.90E+00 W-12 L2173-12 04 Zr-95 -6.OOE-01 1.90E+00 6.80E+00 W-13 L2173-13 04 AcTh-228 -3.90E+O0 4.10E+00 1.50E+01 W-13 L2173-13 04 Ag-108m -1.05E+00 7.60E-0I 2.80E+O0 W-13 L2173-13 04 Ag-I lOm -4.OOE-OI 1.40E+00 5.OOE+00 W-13 L2173-13 04 Ba-140 -1.80E+00 3.OOE+00 L.1OE+OI W-13 L2173-13 04 Be-7 -3.OOE+00 9.20E+00 3.20E+01 W-13 L2173-13 04 Ce-141 -4.OOE+00 1.90E+00 6.70E+00 W-13 L2173-13 04 Ce-144 2.60E+00 5.30E+00 1.80E+01 W-13 L2173-13 04 Co-57 -4.40E-0O 7.OOE-01 2.40E+O0 W-13 L2173-13 04 Co-58 4.OOE-01 l.OOE+00 3.60E+00 W-13 L2173-13 04 Co-60 3.OOE-0O 1.lOE+O0 3.90E+O0 W-13 L2173-13 04 Cr-51 2.OOE+O0 1.30E+01 4.50E+01 W-13 L2173-13 04 Cs-134 -1.60E-01 9.70E-01 3.40E+O0 W-13 L2173-13 04 Cs-137 -1.OOE+00 l.lOE+00 3.90E+00 W-13 L2173-13 04 Fe-59 6.20E+00 3.10E+00 9.80E+00 W-13 L2173-13 04 H-3 -2.70E+02 3.90E+02 1.20E+03 W-13 L2173-13 04 1-131 -3.90E+O0 6.10E+00 2.10E+O1 W-13 L2173-13 04 K-40 4.OOE+01 1.70E+01 5.40E+01 W-13 L2173-13 04 La-140 -2.00E+00 3.40E+00 1.30E+01 W-13 L2173-13 04 Mn-54 -1.92E+O0 9.60E-01 3.60E+00 W-13 L2173-13 -04 Nb-95 -2.OOE+00 1.70E+00 6.OOE+00 W-13 L2173-13 04 Ru-103 -1.80E+00 1.30E+00 4.60E+00 W-13 L2173-13 04 Ru-106 2.70E+00 8.70E+00 3.OOE+0O W-13 L2173-13 04 Sb-124 6.OOE-0I 2.60E+00 9.20E+00 W-13 L2173-13 04 Sb-125 -2.90E+00 2.40E+00 8.60E+00 W-13 L2173-13 04 Se-75 2.OOE-0I 1.30E+00 4.40E+00 W-13 L2173-13 04 Zn-65 2.60E+00 2.70E+00 8.70E+O0 W-13 L2173-13 04 Zr-95 1.90E+00 1.80E+00 5.90E+00 W-14 L2173-14 04 AcTh-228 7.40E+00 4.60E+00 1.50E+O1 W-14 L2173-14 04 Ag-108m -5.OOE-02 8.10E-01 2.80E+00 W-14 L2173-14 04 Ag-I lOIm 5.OOE-01 1.30E+O0 4.60E+00 W-14 L2173-14 04 Ba-140 -3.OOE-01 3.OOE+00 1.lOE+0O W-14 L2173-14 04 Be-7 2.32E+01 9.50E+00 3.OOE+01 W-14 L2173-14 04 Ce-141 -5.00E+00 2.20E+00 7.80E+00 W-14 L2173-14 04 Ce-144 5.60E+00 5.70E+00 l.90E+01 W-14 L2173-14 04 Co-57 4.90E-01 7.50E-01 2.50E+00
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-195
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCilkg)
W-14 L2173-14 04 Co-58 LOOE-01 1.10E+00 4.00E+00 W-14 L2173-14 04 Co-60 1.18E+00 9.70E-01 3.30E+00 W-14 L2173-14 04 Cr-51 -1.10E+01 1.30E+01 4.40E+0I W-14 L2173-14 04 Cs-134 8.OOE-01 L.IOE+00 3.70E+00 W-14 L2173-14 04 Cs-137 5.00E-01 .IOE+00 3.60E+00 W-14 L2173-14 04 Fe-59 -1.50E+00 3.20E+00 L.20E+0I W-14 L2173-14 04 H-3 4.50E+02 3.80E+02 1.IOE+03 W-14 L2173-14 04 1-131 -8.80E+00 6.00E+00 2.10E+01 W-14 L2173-14 04 K-40 6.OOE+00 1.60E+01 5.60E+01 W-14 L2173-14 04 La-140 -4.OOE-0l 3.40E+00 1.30E+01 W-14 L2173-14 04 Mn-54 -2.10E+00 9.90E-01 3.70E+00 W-14 L2173-14 04 Nb-95 -2.30E+00 1.50E+00 5.50E+00 W-14 L2173-14 04 Ru-103 -4.00E+00 L.40E+00 5.10E+00 W-14 L2173-14 04 Ru-106 -4.20E+00 9.30E+00 3.30E+01 W-14 L2173-14 04 Sb-124 -1.20E+00 2.90E+00 1.10E+01 W-14 L2173-14 04 Sb-125 -6.00E+00 2.60E+00 9.30E+00 W-14 L2173-14 04 Se-75 LOOE-01 1.30E+00 4.50E+00 W-14 L2173-14 04 Zn-65 -3.40E+00 2.502+00 9.10E+00 W-14 L2173-14 04 Zr-95 -4.00E-01 L.90E+00 6.80E+00
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-196
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
W-1 L2701-01 17 AcTh-228 1.40E+00 6.50E+00 2.30E+01 W-l L2701-01 17 Ag-108m 2.OOE-01 1.30E+00 4.60E+OO W-1 L2701-01 17 Ag-ll0m -1.70E+00 2.60E+00 9.50E+O0 W-1 L2701-01 17 Ba-140 -9.OOE-01 3.30E+00 1.30E+0O W-l L2701-01 17 Be-7 -1.50E+01 1.50E+01 5.60E+01 W-l L2701-01 17 Ce-141 7.00E-01 3.1OE+00 I.OOE+01 W-1 L2701-01 17 Ce-144 -1.60E+0 I.OOE+0 3.60E+01 W-1 L2701-01 17 Co-57 1.40E+00 1.30E+00 4.30E+00 W-1 L2701-01 17 Co-58 4.40E+00 1.80E+00 5.50E+00 W-l L2701-01 17 Co-60 8.00E-01 1.80E+00 6.30E+00 W-1 L2701-01 17 Cr-51 -2.OOE+01 1.70E+01 5.90E+01 W-1 L2701-01 17 Cs-134 3.OOE+00 1.80E+00 6.OOE+00 W-1 L2701-01 17 Cs-137 -2.20E+00 1.70E+00 6.40E+00 W-l L2701-01 17 Fe-59 1.40E+00 5.10E+00 1.90E+OI W-l L2701-01 17 H-3 -4.70E+02 4.30E+02 1.30E+03 W-1 L2701-01 17 1-131 5.OOE-01 3.90E+00 1.40E+OI W-l L2701-01 17 K-40 -3.30E+01 2.30E+01 8.80E+01 W-1 L2701-01 17 La-140 -1.IOE+00 3.80E+00 1.40E+01 W-l L2701-01 17 Mn-54 -I.OOE-01 1.60E+00 5.80E+00 W-l L2701-01 17 Nb-95 -4.OOE-01 1.90E+00 7.OOE+00 W-1 L2701-01 17 Ru-103 3.OOE-01 1.90E+00 6.50E+00 W-l L2701-01 17 Ru-106 -4.OOE+00 1.60E+01 5.70E+01 W-l L2701-01 17 Sb-124 1.80E+00 4.60E+00 1.70E+O1 W-1 L2701-01 17 Sb-125 2.70E+00 4.OOE+00 1.40E+O1 W-1 L2701-01 17 Se-75 I.OOE-01 2.10E+00 7.10E+00 W-1 L2701-01 17 Zn-65 -5.90E+00 3.80E+00 1.50E+01 W-l L2701-01 17 Zr-95 3.OOE+00 2.90E+00 9.70E+00
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-197
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
W-2 L2701-02 17 AcTh-228 -3.70E+00 6.40E+00 2.30E+01 W-2 L2701-02 17 Ag-108m 0.OOE+00 l.lOE+00 4.00E+00 W-2 L2701-02 17 Ag-l lOm -1.90E+00 2.00E+00 7.50E+00 W-2 L2701-02 17 Ba-140 O.OOE+00 3.OOE+00 1.10+01 W-2 L2701-02 17 Be-7 7.OOE+00 1.30E+01 4.40E+0O W-2 L2701-02 17 Cc-141 -2.70E+00 2.20E+00 7.60E+00 W-2 L2701-02 17 Ce-144 5.80E+00 7.00E+00 2.40E+01 W-2 L2701-02 17 Co-57 2.60E-01 9.00E-01 3.10E+00 W-2 L2701-02 17 Co-58 1.OOE-01 1.40E+00 5.10E+00 W-2 L2701-02 17 Co-60 -1.80E+00 1.50E+00 6.20E+00 W-2 L2701-02 17 Cr-51 -9.00+00 1.40E+01 4.90E+0O W-2 L2701-02 17 Cs-134 8.00E-01 1.402+00 5.OOE+00 W-2 L2701-02 17 Cs-137 7.00E-01 1.502+00 5.40E+00 W-2 L2701-02 17 Fe-59 -1.60E+00 4.40E+00 1.70E+01 W-2 L2701-02 17 H-3 -5.20E+02 4.30E+02 1.40E+03 W-2 L2701-02 17 1-131 1.90E+00 3.60E+00 1.20E+01 W-2 L2701-02 17 K-40 9.00E+00 2.50E+01 8.80E+01 W-2 L2701-02 17 La-140 O.OOE+00 3.50E+00 1.30E+01 W-2 L2701-02 17 Mn-54 -2.00E-01 1.502+00 5.50E+00 W-2 L2701-02 17 Nb-95 4.OOE-0O 2.00E+00 7.10E+00 W-2 L2701-02 17 Ru-103 1.60E+00 1.602+00 5.40E+00 W-2 L2701-02 17 Ru-106 3.00E+00 1.40E+01 4.902+01 W-2 L2701-02 17 Sb-124 -2.90E3+00 4.00E+00 1.60E+01 W-2 L2701-02 17 Sb-125 6.70E+00 3.30E+00 1.10E+01 W-2 L2701-02 17 Se-75 -2.00E-01 1.70E+00 5.90E+00 W-2 L2701-02 17 Zn-65 -2. 1OE+00 3.30E+00 1.20E+01 W-2 L2701-02 17 Zr-95 -1.30E+00 2.60E+00 9.50E+00 W-3 L2701-03 17 AcTh-228 5.00E-01 6.60E+00 2.30E+01 W-3 L2701-03 17 Ag-108m -1.90E+00 1.20E+00 4.20E+00 W-3 L2701-03 17 Ag-l lOm -3.80E+00 2.00E+00 7.70E+00 W-3 L2701-03 17 Ba-140 2.00E+00 3.40E+00 1.20E+01 W-3 L2701-03 17 Be-7 -1.90E+01 1.50E+01 5.30E+0O W-3 L2701-03 17 Ce-141 -8.00E-01 2.80E+00 9.50E+00 W-3 L2701-03 17 Ce-144 -9.1OE+00 9.002+00 3.10E+01 W-3 L2701-03 17 Co-57 -1 .OOE-0O 1.20E+00 3.90E+00 W-3 L2701-03 17 Co-58 -L.OOE-01 1.602+00 5.60E+00 W-3 L2701-03 17 Co-60 2.00E-01 1.30E+00 4.70E+00 W-3 L2701-03 17 Cr-51 4.OOE+00 1.502+01 5.10E+01 W-3 L2701-03 17 Cs- 134 -1.00+00 1.60E+00 5.70E+00 W-3 L270i-03 17 Cs-137 -5.00E-01 1.50E+00 5.20E+00
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-198
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
W-3 L2701-03 17 Fe-59 -6.30E+00 4.501E+00 I1.80E+01 W-3 L2701-03 17 H-3 0.OOE2+00 4.40E+02 1 .40E+03 W-3 L2701-03 17 1-131 3.50E+00 4.40E+00 1 .501+01 W-3 L2701-03 17 K40 4.60E+01 1.90E+01 5.901E+01 W-3 L2701-03 17 La-140 2.20E+00 3.90E+00 1.40E3+01 W-3 L2701-03 17 Mn-54 2.60E+00 1.60E+00 5.30E+00 W-3 L2701-03 17 Nb-95 2.20E+00 1.70E+00 5.80E+00 W-3 L2701-03 17 Ru-103 -1 .90E+O0 I1.70E+00 6.20E+00 W-3 L2701-03 17 Ru-106 2.OOE+01 1.3013-01 4.401E+01 W-3 L2701-03 17 Sb-124 3.OOE+00 3.50E+00 I1.20E+01 W-3 L2701-03 17 Sb-125 -2.80E+00 3.603+O00 I1.30E+01 W-3 L2701-03 17 Se-75 8.001E-01 I1.901E+00 6.40E+00 W-3 L2701-03 17 Zn-65 1.32E+01 5.301E+00 I1.70E+01 W-3 L2701-03 17 Zr-95 -2.OOE-i00 2.60E3+00 9.401E+00 W-4 L2701-04 17 Acih-228 2.901E+00 5.50E+00 1.90E+01 W-4 L2701-04 17 Ag-108m -1. 1OE+00 1.1OE+00 4.001E+00 W4 L2701-04 17 Ag-I lOm -1 .70E+00 1.90E+00 6.90E+00 W4 L2701-04 17 Ba-140 4.OOE-01 2.301E+00 8.40E+00 W-4 L2701-04 17 Be-7 -4.OOE+00 1.IOE+01 3.90E+01 W-4 L2701-04 17 Ce-141 5.00OE-01' 2.001E+00 6.80E+00 W-4 L2701-04 17 Cc-144 -6.1IOE+00 7.OOE+00 2.501E+01 W-4 L2701-04 17 Co-57 -1. IOE-01 9.201E-01 3.20E+00 W4 L2701-04 17 Co-58 -2.30E+00 1.30E+00 5.10E+00 W-4 L2701-04 17 Co-60 -9.001E-01 1.60E+00 5.80E3+00 W4 L2701-04 17 Cr-51 -1.40E+01 I1.30E+01 4.801E+01 W-4 L2701-04 17 Cs-134 1.1OE+00 1.20E+00 4.101E+00 W-4 L2701-04 17 Cs-137 -6.OOE-01 1.40E+O0 5.20E-e00 W4 L2701-04 17 Fe-59 4.00OE-01 4.OOE+00 1.40E+01 W4 L2701-04 17 H-3 5.OOE+02 4.50E+02 1.40E+03 W4 L2701-04 17 1-131 2.201E+00 3.20E+O0 1.IOE+01 W4 L2701-04 17 K40 1.401E+01 2.001E+01 6.801E+01 W4 L2701-04 17 La-140 4.001E-01 2.60E+00 9.70E+00 W4 L2701 -04 17 Mn-54 -3.101+00 1.20E+00 4.80E+00 W4 L2701-04 17 Nb-95 -4.80E+00 I1.701E+00 6.60E+00 W4 L2701-04 17 Ru-103 -9.OOE-01 I1.30E+00 4.70E+00 W4 L2701-04 17 Ru-106 -2.70E+01 I1.30E+01 4.80E+01 W4 L2701-04 17 Sb-124 -5.OOE-01 3. I OE+00 I1.20E+01 W4 L2701-04 17 Sb-125 -3.20E+00 3.40E3+00 I1.20E+01 W4 L2701-04 17 Se-75 1.1OE+00 I1.60E+00 5.50E+00 W4 L2701-04 17 Zn-65 -7.OOE-01 2.70E+00 9.90E+00
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-199
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
W-4 L2701-04 17 Zr-95 -6.OOE-0 1.90E+00 7.10E+00 W-5 L2701-05 17 AcTh-228 2.10E+00 3.80E+00 1.30E+01 W-5 L2701-05 17 Ag-108m 2.80E-01 6.20E-01 2.10E+00 W-5 L2701-05 17 Ag-i lOnm 1.OOE+O0 9.80E-01 3.30E+00 W-5 L2701-05 17 Ba-140 -2.60E+00 2.OOE+00 7.40E+00 W-5 L2701-05 17 Be-7 5.70E+00 6.80E+00 2.30E+01 W-5 L2701-05 17 Ce-141 -7.00E-01 2.20E+00 7.40E+00 W-5 L2701-05 17 Ce-144 0.002+00 4.20E+00 1.40E+01 W-5 L2701-05 17 Co-57 3.80E-01 5.40E-01 1.80E+00 W-S L2701-05 17 Co-58 2.1OE-01 7.20E-01 2.50E+00 W-5 L2701-05 17 Co-60 8.80E-01 7.60E-01 2.60E+00 W-5 L2701-05 17 Cr-51 7.60E+00 8.90E+00 3.OOE+01 W-5 L2701-05 17 Cs-134 -4.60E-01 6.902-01 2.502+00 W-5 L2701-05 17 Cs-137 -1.26E+00 7.70E-01 2.802+00 W-5 L2701-05 17 Fe-59 I.OOE+00 2.40E+00 8.40E+00 W-5 L2701-05 17 H-3 -1.10+02 4.40E+02 1.40E+03 W-5 L2701-05 17 1-131 -7.00E-01 3.50E+00 1.20E+01 W-5 L2701-05 17 K-40 6.50E+01 1.402+01 4.302+01 W-5 L2701-05 17 La-140 -3.OOE+00 2.30E+00 8.50E+00 W-5 L2701-05 17 Mn-54 -2.31E+00 7.50E-01 2.80E+00 W-5 L2701-05 17 Nb-95 -4.00E-02 9.402-01 3.302+00 W-5 L2701-05 17 Ru-103 -3.16E+00 8.602-01 3.20E+00 W-5 L2701-05 17 Ru-106 -7.80E+00 7.30E+00 2.60E+01 W-5 L2701-05 17 Sb-124 2.50E+00 1.902+00 6.20E+00 W-5 L2701-05 17 Sb-125 O.OOE+00 1.90E+00 6.60E+00 W-5 L2701-05 17 Se-75 -1.51E+00 9.70E-01 3.40E+00 W-5 L2701-05 17 Zn-65 1.30E+00 1.50E+00 5.20E+00 W-5 L2701-05 17 Zr-95 9.002-01 1.40E+00 4.70E+00 W-6 L2701-06 17 AcTh-228 5.102+00 2.80E+00 9.20E+00 W-6 L2701-06 17 Ag-108m 4.10E-01 6.20E-01 2.10E+00 W-6 L2701-06 17 Ag-I1lm -2.004-01 1.10+00 3.70E+00 W-6 L2701-06 . 17 Ba-140 -3.60E+00 2.00E+00 7.50E+00 W-6 L2701-06 17 Be-7 1.75E+01 6.90E+00 2.20E+01 W-6 L2701-06 17 Ce-141 1.70E+00 1.80E+00 6.002+00 W-6 L2701-06 17 Cc-144 -2.00E+00 4.402+00 1.502+01 W-6 L2701-06 17 Co-57 -1.48E+00 5.60E-01 1.90E+00 W-6 L2701-06 17 Co-58 -7.60E-01 7.802-01 2.80E+00 W-6 L2701-06 17 Co-60 3.00E-02 7.402-01 2.60E+00 W-6 L2701-06 17 Cr-51 -1.62E+01 8.902+00 3.10E+01 W-6 L2701-06 17 Cs-134 1.75E+00 8.00E-01 2.60E+00
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-200
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
W-6 L2701-06 17 Cs-137 7.20E-01 7.50E-01 2.50E+00 W-6 L2701-06 17 Fe-59 -2.00E-01 2.10E+00 7.60E+00 W-6 L2701-06 17 H-3 3.10E+02 4.40E+02 1.302+03 W-6 L2701-06 17 1-131 2.30E+00 3.60E+00 1.202+01 W-6 L2701-06 17 K-40 5.40E+0O 1.30E+01 4.00E+01 W-6 L2701-06 17 La-140 -4.101+.00 2.30E+00 8.60E+00 W-6 L2701-06 17 Mn-54 -7.10E-01 7.60E-01 2.70E+00 W-6 L2701-06 17 Nb-95 3.00E-01 1.50E+00 5.10E+00 W-6 L2701-06 17 Ru-103 -6.40E-0O 8.90E-01 3.10E+00 W-6 L2701-06 17 Ru-106 -1.20E+00 7.30E+00 2.50E+01 W-6 L2701-06 17 Sb-124 3.70E+00 2.20E+00 7.302+00 W-6 L2701-06 17 Sb-125 -1.90E+00 1.90E+00 6.50E+00 W-6 L2701-06 17 Se-75 -5.80E-0O 9.70E-01 3.30E+00 W-6 L2701-06 17 Zn-65 2.90E+00 2.50E+00 8.102+00 W-6 L2701-06 17 Zr-95 -1.OOE-01 1.40E+00 4.80E+00 W-7 L2701-07 17 AcTh-228 4.30E+00 2.50E+00 8.20E+00 W-7 L2701-07 17 Ag-108m 3.00E-02 5.60E-01 1.902+00 W-7 L2701-07 17 Ag-Ilbm 5.00E-01 1.002+00 3.40E+00 W-7 L2701-07 17 Ba-140 3.50E+00 2.10E+00 6.70E+00 W-7 L2701-07 17 Be-7 1.39E+01 6.40E+00 2.10E+01 W-7 L2701-07 17 Cc-141 -3.00E-01 1.70E+00 5.80E+00 W-7 L2701-07 17 Cc-144 7.OOE-01 3.70E+00 1.20E+01 W-7 L2701-07 17 Co-57 1.20E-01 6.80E-01 2.30E+00 W-7 L2701-07 17 Co-58 -9.60E-01 7.20E-01 2.60E+00 W-7 L2701-07 17 Co-60 1.96E+00 7.70E-01 2.402+00 W-7 L2701-07 17 Cr-51 2.60E+00 8.60E+00 2.90E+01 W-7 L2701-07 17 Cs-134 7.40E-0O 7.10E-01 2.40E+00 W-7 L2701-07 17 Cs-137 -1.30E+00 7.20E-01 2.60E+00 W-7 L2701-07 17 Fe-59 -9.00E-01 2.30E+00 8.30E+00 W-7 L270i -07 17 H-3 -1.50E+02 4.40E+02 1.40E+03 W-7 L2701-07 17 1-131 6.70E+00 4.90E+00 1.602+01 W-7 L2701-07 17 K-40 -1.20E+01 1.30E+01 4.60E+01 W-7 L2701-07 17 La-140 4.OOE+00 2.40E+00 7.70E+00 W-7 L2701-07 17 Mn-54 -6.30E-01 6.30E-01 2.30E+00 W-7 L2701-07 17 Nb-95 2.OOE-01 1.40E+00 4.70E+00 W-7 L2701-07 17 Ru-103 -1.81E+00 8.70E-01 3.10E+00 W-7 L2701-07 17 Ru-106 -7.10E+00 6.70E+00 2.40E+01 W-7 L2701-07 17 Sb-124 9.00E-01 1.90E+00 6.60E+00 W-7 L2701-07 17 Sb-125 l.OOE-01 1.70E+00 5.70E+00 W-7 L2701-07 17 Se-75 -3.60E-01 8.00E-01 2.70E+00
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-201
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
W-7 L2701-07 17 Zn-65 - LI. 0OE+00 1.60E3+00 5.50E+00 W-7 L2701-07 17 Zr-95 -I.OOE+00 I1.40E+00 5.OOE+00 W-8 L2701-08 17 Acih-228 -1.90E+00 4.OOE1e-00 1.401E+01 W-8 L2701-08 17 Ag-108m -1 .941E.00 7.001E-01 2.60E3+00 W-8 L2701-08 17 Ag-I lOm -2.OOE-01 I1.20E+00 4.401E+00 W-8 L2701-08 17 Ba-140 -2.50E+00 2.601E+00 9.90E+00 W-8 L2701-08 17 Be-7 0.OOE+00 8.50E-,00 2.90E+01 W-8 L2701-08 17 Ce-141 -4.5S1E+00 1.90E+00 6.80E+00 W-8 L2701-08 17 Ce-144 -4.IOE+00 4.601E+00 1.60E+01 W-8 L2701-08 17 Co-57 -3.90E-01 7.701E-01 2.60E+00 Wv-8 L2701-08 17 Co-58 -1 .83E-i00 8.60E3-01 3.301E+00 W-8 L2701-08 17 Co-60 -5.00OE-01 9.20E-01 3.30E+00 W-.8 L2701-08 17 Cr-51 8.OOE+00 1.IOE3+01 3.70E+01 Wv-8 L2701-08 17 Cs-134 1.141E+00 8.30E3-01 2.70E+00 Wv-s L2701-08 17 Cs-137 5.101E-01 8.901E-01 3.OOE+00 Wv-8 L2701-08 17 Fe-59 -4.0013+00 3. l0E+00 I1.20E+01 Wv-8 L2701-08 17 H-3 4.40E+02 4.20E+02 1.30E+03 W-8 L2701-08 17 1-131 2.301E+00 5.901E+00 2.001E+01 Wv-8 L2701-08 17 K-40 -1.90E+01 .1.50E+01 5.40E+01 Wv-8 L2701-08 17 La-140 -2.90E+00 3.OOE+00 l.IOE+01 W-8 L2701-08 17 Mn-54 2.60E-01 7.701E-01 2.70E+00 W-8 L2701-08 17 Nb-95 I1.70E+00 I1.20E1e-00 3.90E-e00 Wv-8 L2701-08 17 Ru-103 1.OOE3+00 1.IOE+00 3.80E-t00 W-8 L2701-08 17 Ru-106 3. 1O1+O00 8.501E+00 2.90E+01 W-8 L2701-08 17 Sb-124 1.1OE3+00 2.40E+00 8.30E+00 W-8 L2701-08 17 Sb-125 -1 .50E+00 2.20E+00 7.80E+00
'v.8 L2701 08 17 Se-75 -9.701E-01 9.60E3-01 3.40E+00 Wv-8 L2701-08 17 Zn-65 1.OOE+00 I1.90E+O0 6.50E-400 Wv-s L2701-08 17 Zr-95 .-4.60E+00 I1.801E+00 6.70E+O0 W-9 L2701-09 17 AcTh-228 8.OOE3-01 7.60E1,-00 2.70E+01 Wv-9 L2701-09 17 Ag- 108m -5.0OE-01 I1.401E+00 5.10E+00 W-9 L2701-09 17 Ag-i lOm -1.60E+00 2.70E+00 l.OOE+i01 Wv.9 L2701-09 17 Ba-140 0.OOE3+00 2.501E+00 9.60E+00 Wv-9 L2701-09 17 Be-7 1.OOE1e-00 1.30E+01 4.701E+01 Wv.9 L2701-09 17 Cc-141 -2.70E+i00 2.40E+00 8.50E+00 W-9 L2701-09 17 Ce-144 -4.30E+00 8.20E+00 2.90E+01 Wv-9 L2701-09 17 Co-57 -5.001E-01 I .OOE+00 3.60E+O00
'v.9 L2701-09 17 Co-58 2.201E+00 I1.70E1i-00 5.70E+00 W-9 L2701-09 17 Co-60 6.00OE-01 2.10OE+00 7.60E-e00 Wv-9 L2701-09 17 Cr-51 -1.50E+01 I1.50E+01 5.40E3+01
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-202
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
W-9 L2701-09 17 Cs-134 -1.70E+00 1.80E+00 6.80E+00 W-9 L2701-09 17 Cs-137 1.20E+00 1.80E+00 6.30E+00 W-9 L2701-09 17 Fe-59 -3.20E+00 5.90E+00 2.20E+0O W-9 L2701-09 17 H-3 5.OOE+02 4.20E+02 1.30E+03 W-9 L2701-09 17 1-131 -l.IOE+00 3.OOE+00 1.1OE+01 W-9 L2701-09 17 K-40 -3.OOE+O0 2.70E+01 9.70E+I01 W-9 L2701-09 17 La-140 O.OOE+00 2.80E+00 I.1OE+01 W-9 L2701-09 17 Mn-54 2.OOE-01 1.70E+00 6.20E+00 W-9 L2701-09 17 Nb-95 -1.20E+00 1.80E+00 6.80E+00 W-9 L2701-09 17 Ru-103 -1.OOE+00 1.70E+00 6.20E+00 w-9 L2701-09 17 Ru-106 3.OOE+00 1.50E+01 5.40E+01 w-9 L2701-09 17 Sb-124 -5.40E+00 4.OOE+00 1.70E+0O w-9 L2701-09 17 Sb-125 -3.20E+00 4.30E+00 1.60E+OI W-9 L2701-09 17 Se-75 -1.40E+00 l.90E+00 6.70E+00 W-9 L2701-09 17 Zn-65 -1.60E+00 3.80E+00 1.40E+0O W-9 L2701-09 17 Zr-95 -2.40E+00 2.80E+00 I.IOE+0O W-10 L2701-10 17 AcTh-228 2.OOE+00 5.50E+00 1.90E+01 W-10 L2701-10 17 Ag-108m 1.60E+00 1.IOE+00 3.70E+00 W-10 L2701-10 17 Ag-lOrm 2.60E+00 1.70E+00 5.80E+00 W-10 L2701-10 17 Ba-140 l.OOE+00 2.20E+00 7.80E+00 W-10 L2701-10 17 Be-7 7.OOE+00 l.IOE+0 3.70E+01 W-10 L2701-10 17 Cc-141 4.40E+00 1.90E+00 6.30E+00 W-10 L2701 -10 17 Ce-144 1.80E+00 7.20E+00 2.50E+01 W-10 L2701-10 17 Co-57 9.50E-01 9.20E-01 3.10E+00 W-10 L2701-10 17 Co-58 7.OOE-01 1.20E+00 4.20E+00 W-10 L2701-10 17 Co-60 1.50E+00 1.40E+00 4.60E+O0 W-10 L2701-10 17 Cr-51 -9.OOE+00 1.30E+01 4.50E+01 W-10 L2701-10 17 Cs-134 3.OOE-01 1.20E+00 4.20E+00 W-10 L2701-10 17 Cs-137 -4.OOE-01 1.50E+00 5.20E+00 W-10 L2701-10 17 Fe-59 -4.OOE-01 3.70E+00 1.40E+0O W-10 L2701-10 17 H-3 6.90E+02 4.30E+02 1.30E+03 W-10 L2701-10 17 1-131 1.60E+00 2.60E+00 9.OOE+00 W-10 L2701-10 17 K-40 1.44E+0O 9.50E+00 3.20E+01 W-10 L2701-10 17 La-140 1.1OE+00 2.50E+00 8.90E+00 W-10 L2701-10 17 Mn-54 -7.OOE-01 1.30E+00 4.90E+00 W-10 L2701-10 17 Nb-95 O.OOE+00 1.50E+00 5.40E+00 W-10 L2701-10 17 Ru-103 -9.OOE-0O 1.50E+00 5.50E+00 W-10 L2701-10 17 Ru-106 -2.70E+0O 1.30E+01 5.OOE+01 W-10 L2701-10 17 Sb-124 -2.60E+00 2.50E+00 1.IOE+01 W-10 L2701-10 17 Sb-125 3.40E+00 3.30E+00 1.IOE+01
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-203
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
W-Io L2701-10 17 Se-75 2.70E+00 1.70E+OO 5.50E+00 W-1o L2701-10 17 Zn-65 -4.1OE+00 2.80E+OO 1.lOE+O I W-10 L2701-10 17 Zr-95 -2.40E+00 2.OOE+00 7.80E+00 WI'1 L2701-11 17 AcTh-228 9.IOE+00 5.IOE+00 1.70E+01 L2701-11 17 Ag- 108m 3.OOE-01 l.OOE+OO 3.60E+00 W-II L2701-11 17 Ag-I lOm 4.OOE-01 1.70E+00 6. 10E+00 W-11 L2701-11 17 Ba-140 2.80E+00 2.70E+OO 9.40E+0O W-1I w-1I L2701-11 17 Be-7 7.OOE+O0 1.20E+01 4.OOE+01 W-11 L2701-11 17 Ce-141 4.OOE-01 2.40E+00 8.1OE+OO w-II L2701-11 17 Ce-144 -7.OOE-01 7.50E+00 2.60E+01 W-1 L2701-11 17 Co-57 7.OOE-01 9.80E-O1 3.30E+00 W-'I L2701-11 17 Co-58 -9.OOE-01 1.30E+00 5.OOE+00 W-1 L2701-11 17 Co-60 1.60E+0O 1.30E+00 4.50E+OO W-lI L2701-11 17 Cr-51 -4.OOE+00 1.40E+O1 4.80E+01 W-11 L2701-11 17 Cs- 134 6.OOE-01 1.40E+00 5.OOE+00 W-11 L2701-11 17 Cs-137 -5.OOE-01 1.20E+00 4.50E+00 W-11 L2701-11 17 Fe-59 7.OOE-01 3.80E+00 1.40E+I01 W-11 L2701-11 17 H-3 2.OOE+02 4.20E+02 1.30E+03 W-11 L2701-11 17 1-131 8.OOE-01 4.OOE+00 1.40E+01 W-1l L2701-1 1 17 K-40 -1.IOE+I01 1.90E+01 7.OOE+01 W-ll L2701-1 1 17 La-140 3.20E+00 3.20E+00 1.lOE+01 W-1l L2701-1 I 17 Mn-54 -4.OOE-01 1.30E+00 4.80E+OO W-1l L2701-11 17 Nb-95 -2.OOE-O1 1.60E+O0 5.70E+OO W-ll L2701-11 17 Ru-103 -4.50E+00 1.40E+OO 5.40E+O0 W-ll L2701-11 17 Ru-106 9.OOE+OO 1.20E+01 4.20E+01 W-ll L2701-11 17 Sb-124 5.40E+00 3.60E+OO 1.20E+01 W-ll L2701-11 17 Sb- 125 4.50E+00 3.30E+00 1.1OE+01 -
W-ll W-ll L2701-11 17 Se-75 8.OOE-01 1.60E+00 5.50E+OO W-1l L2701-11 17 Zn-65 -4.OOE-01 2.80E+00 l.OOE+I01 L2701-1 I 17 Zr-95 -7.OOE-01 2.20E+OO 8.OOE+OO W-12 L2701-12 17 AcTh-228 2.20E+00 4.50E+00 1.60E+O1 W-12 L2701-12 17 Ag-108m -1.70E-01 9.40E-01 3.30E+O0 W-12 L2701-12 17 Ag- lOnm -6.OOE-01 1.90E+O0 6.70E+00 W-12 L2701-12 17 Ba-140 1.50E+O0 2.50E+00 9.OOE+O0 W-12 L2701-12 17 Be-7 7.OOE+00 1.lOE+O1 3.70E+01 W-12 L2701-12 17 Ce-141 1.90E+00 2.20E+O0 7.40E+00 W-12 L2701-12 17 Cc-144 3.30E+00 7.40E+00 2.50E+01 W-12 L2701-12 17 Co-57 1.45E+OO 9.40E-01 3. 1OE+0O W-12 L2701-12 17 Co-58 -I.OOE+00 1.20E+0O 4.60E+-O0 W-12 L2701-12 17 Co-60 -2.90E+OO 1.30E+OO 5.30E+00
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-204
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
W-12 L2701-12 17 Cr-51 3.OOE+00 1.30E+01 4.50E+01 W-12 L2701-12 17 Cs-134 -1.00E+00 1.40E+00 5.20E+00 W-12 L2701-12 17 Cs-137 3.00E-01 1.30E+00 4.70E+00 W-12 L2701-12 17 Fe-59 -5.30E+00 3.40E+00 1.40E+01 W-12 L2701-12 17 H-3 -3.OOE+01 4.20E+02 1.30E+03 W-12 L2701-12 17 1-131 2.60E+00 3.70E+00 1.30E+01 W-12 L2701-12 17 K-40 1.10E+01 2.00E+01 7.00E+01 W-12 L2701-12 17 La-140 1.80E+00 2.90E+00 l.OOE+01 W-12 L2701-12 17 Mn-54 6.OOE-01 1.20E+00 4.20E+00 W-12 L2701-12 17 Nb-95 3.40E+00 1.60E+00 5.10E+00 W-12 L2701-12 17 Ru-103 -1.60E+00 1.30E+00 4.90E+00 W-12 L2701-12 17 Ru-106 l.OOE+00 1.20E+01 4.10E+01 W-12 L2701-12 17 Sb-124 -7.00E+00 3.60E+00 1.50E+01 W-12 L2701-12 17 Sb-125 -8.003-01 3.20E+00 1.10E+01 W-12 L2701-12 17 Se-75 1.10E+00 1.70E+00 5.70E+00 W-12 L2701-12 17 Zn-65 l.OOE-01 3.90E+00 1.40E+01 W-12 L2701-12 17 Zr-95 1.lOE+00 2.10E+00 7.50E+00 W-13 L2701-13 17 AcTh-228 -3.80E+00 5.20E+00 1.90E+01 W-13 L2701-13 17 Ag-108m 1.60E+00 1.10E+00 3.60E+00 W-13 L2701-13 17 Ag-I lOm O.OOE+00 1.80E+00 6.30E+00 W-13 L2701-13 17 Ba-140 3.20E+00 2.10E+00 6.90E+00 W-13 L2701-13 17 Be-7 l.OOE+00 1.10E+01 3.80E+01 W-13 L2701.13 17 Ce-141 1.60E+00 1.90E+00 6.40E+00 W-13 L2701-13 17 Ce-144 3.40E+00 7.20E+00 2.40E+01 W-13 L2701-13 17 Co-57 1.62E+00 9.50E-01 3.10E+00 W-13 L2701-13 17 Co-58 3.00E-01 1.30E+00 4.60E+00 W-13 L2701-13 17 Co-60 -3.OOE-01 1.30E+00 5.00E+00 W-13 L2701-13 17 Cr-51 -2.90E+0O 1.30E+01 4.70E+01 W-13 L2701-13 17 Cs-134 1.10E+00 1.40E+00 4.70E+00 W-13 L2701-13 17 Cs-137 -l.OOE-01 1.30E+00 4.80E+00 W-13 L2701-13 17 Fe-59 -6.20E+00 3.70E+00 1.50E+01 W-13 L2701-13 17 H-3 1.20E+03 4.30E+02 1.30E+03 W-13 L2701-13 17 1-131 -2.20E+00 2.40E+00 8.60E+00 W-13 L2701-13 17 K-40 5.60E+01 2.30E+01 7.20E+01 W-13 L2701-13 17 La-140 3.60E+00 2.40E+00 7.90E+00 W-13 L2701-13 17 Mn-54 1.OOE+00 1.30E+00 4.30E+00 W-13 L2701-13 17 Nb-95 -3.40E+O0 1.60E+00 6.30E+00 W-13 L2701-13 17 Ru-103 2.00E-01 1.50E+00 5.30E+00 W-13 L2701-13 17 Ru-106 -6.OOE+00 1.20E+0I 4.50E+01 W-13 L2701-13 17 Sb-124 5.OOE-01 3.40E+00 1.30E+01
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-205
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
W-13 L2701-13 17 Sb-125 3.40E+00 3.50E+00 1.20E+01 W-13 L2701-13 17 Se-75 -7.00E-01 1.70E+00 6.1OE+00 W-13 L2701-13 17 Zn-65 -3.OOE-01 3.50E+00 1.30E+01 W-13 L2701-13 17 Zr-95 -2. 1OE+00 2.20E+00 8.30E+00 W-14 L2701-14 17 AcTh-228 5.90E+00 6.00E+00 2.00E+01 W-14 L2701-14 17 Ag-108m -1.90E+00 1.1OE+00 4.10E+00 W-14 L2701-14 17 Ag-llOm 4.OOE-01 1.60E+00 5.60E+00 W-14 L2701-14 17 Ba-140 -3.10E+00 2.20E+00 8.80E+00 W-14 L2701-14 17 Be-7 -1.40E+01 1.OOE+01 3.90E+01 W-14 L2701-14 17 Ce-141 -1.00E+00 2.20E+00 7.60E+00 W-14 L2701-14 17 Ce-144 5.10E+00 7.40E+00 2.50E+01 W-14 L2701-14 17 Co-57 1.91E+00 9.70E-01 3.10E+00 W-14 L2701-14 17 Co-58 -4.00E-01 1.50E+00 5.40E+00 W-14 L2701-14 17 Co-60 4.OOE-O1 1.40E+00 5.10E+00 W-14 L2701-14 17 Cr-51 -1.40E+O1 1.20E+01 4.40E+01 W-14 L2701-14 17 Cs-134 4.OOE+O0 1.40E+00 4.20E+00 W-14 L2701-14 17 Cs-137 6.00-E-1 1.40E+00 4.70E+00 W-14 L2701-14 17 Fe-59 1.50E+00 3.10E+00 1.1OE+01 W-14 L2701-14 17 H-3 8.70E+02 4.20E+02 1.20E+03 W-14 L2701-14 17 1-131 4.OOE-01 2.40E+00 8.30E+00 W-14 L2701-14 17 K-40 -1.OOE+01 2.10E+01 7.50E+01 W-14 L2701-14 17 La-140 -3.60E+O0 2.60E+00 1.OOE+01 W-14 L2701-14 17 Mn-54 1.80E+00 1.40E+00 4.70E+00 W-14 L2701-14 17 Nb-95 -2.80E+00 1.40E+00 5.60E+00 W-14 L2701 -14 17 Ru-103 -1.50E+00 1.30E+00 4.70E+00 W-14 L2701-14 17 Ru-106 3.00E+00 1.30E+01 4.70E+01 W-14 L2701-14 17 Sb- 124 4.00E-0O 2.70E+00 1.OOE+01 -
W-14 L2701-14 17 Sb- 125 1.1OE+00 3.50E+00 1.20E+01 W-14 L2701-14 17 Se-75 2.30E+00 1.70E+00 5.70E+00 W-14 L2701-14 17 Zn-65 -6.30E+00 3.20E+00 1.20E+01 W-14 L2701-14 17 Zr-95 5.50E+00 2.20E+00 6.90E+00
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-206
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
W-I U3459-01 30 Aclh-228 1.60E+00 5.40E+00 I.90E+01 W-1 U3459-01 30 Ag-108m -3.60E-01 9.60E-01 3.40E+00 W-I U3459-01 30 Ag-i lOm 4.OOE-01 1.80E+00 6.30E+00 W-I U3459-01 30 Ba-140 -4.OOE-01 3.10E+00 1.IOE+01 WI1 U2459-01 30 Be-7 I1.70E+01 l.lOE+01 3.70E+01 W-1 U3459-01 30 Ce-141 1.40E+00 I.90E+00 6.50E+00 W.I L3459-01 30 Ce-144 -3.70E+00 6.OOE+00 2.1OE+01 WI1 U3459-01 30 Co-57 -2.60E-01 7.50E-01 2.60E+00 W-1 U3459-01 30 Co-58 0.OOE+00 1.30E+00 4.50E+00 W-I L3459-01 30 Co-60 -1 .OOE+00 1.40E+00 5.30E+00 W-1 U3459-01 30 Cr-51 1.OOE+01 1.30E+01 4.30E+01 W-1 U3459-01 30 Cs-134 2.00OE-01 1.20E+00 4.20E+00 W-1 U3459-01 30 Cs-137 4.OOE-01 1.lOE+00 4.OOE+00 W-l W3459-01 30 Fe-59 1.60E-e00 4.30E+00 1.50E+01 W-1 U2459-01 30 H-3 -6.OOE+01 3.90E+02 1.20E+03
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-207
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg) w-1 L3459-01 30 1-131 -2.OOE-01 3.70E+00 1.30E-i01 W- L3459-01 30 K-40 2.10E+01 2. 101+0 I 7.IOE+01 W-1 L3459-01 30 La-140 -5.00E-01 3.501E+00 I1.30E+01 W-I L3459-01 30 Mn-54 -5.00E3-01 I1.301E+00 4.501E+00 w-1 L3459-01 30 Nb-95 -1.6013-00 2. IOE-,.00 7.701E+00 W- L3459-01 30 Ru-103 -4.001E-01 I1.30E3+00 4.60E3+00 W-1 L3459-01 30 Ru-106 -7.OOE+00 1.20E+01 4.201E+01 w-l U3459-01 30 Sb-124 5.OOE-01 2.70E+00 1.OOE3+01 w-1 L3459-01 30 Sb-125 -3.70E+00 2.901E+00 1.OOE1i.01 W-. L3459-01 30 Se-75 -6.001E-01 1.50E3+00 5.001E+00 J
w-1 L3459-01 30 Zn-65 -4.OOE+00 3.40E3+00 I1.30E+01 w-1 L3459-01 30 Zr-95 -1.OOE3-01 2.30E+00 8.10E-i00 W-2 L3459-02 30 AcTh-228 4.20E+00 5.20E+00 I1.701E+01 W-2 L3459-02 30 Ag-108m 4.80E-01 7.70E-01 2.60E+00 W-2 L3459-02 30 Ag-I lOm 1.601E+00 1.40E-,.00 4.60E+00 W-2 L3459-02 30 Ba-140 1.70E3+00 2.80E+00 9.801E+00 W-2 L3459-02 30 Be-7 -1.69E+01 9.001E+00 3.30E+01 W-2 L3459-02 30 Ce-141 -4.00OE+00 2.40E3+00 8.301E+00 W-2 L3459-02 30 Ce-144 7.201E+00 4.901E+00 1.60E1e-01 W-2 L3459-02 30 Co-57 -7.701E-01 6.20E-01 2. 101+00 W-2 L3459-02 30 Co-58 -2.OOE-01 9.801E-01 3.501E+00 W-2 U3459-02 30 Co-60 -4.001E-01 1.20E3+00 4.30E-,.00 W-2 L3459-02 30 Cr-51 -1.40E+01 1.OOE3+01 3.601E+01 W-2 L3459-02 30 Cs-134 5.00OE-01 1.20E-i00 4.00OE+00 W-2 L3459-02 30 Cs-137 5.00OE-01 1.OOE-,00 3.60E+00 W-2 L3459-02 30 Fe-59 9.001E-01 2.30E-i.00 7.901E+00 W-2 L3459-02 30 H-3 1.50E+02 3.901E+02 I1.201E+03 W-2 L3459-02 30 1-131 -3.40E+00 3. 101E+00 1.1OE+01 W-2 L3459-02 30 K-40 8.OOE+00 1.801E+01 6. IOE+01 W-2 L3459-02 30 La-140 2.001E+00 3.301E+00 1.1OE+01 W-2 L3459-02 30 Mn-54 -3.OOE-01 1.OOE3+00 3.601E+00 W-2 L3459-02 30 Nb-95 -7.OOE-01 I1.20E+00 4.40E+00 W-2 L3459-02 30 Ru-103 -1.30E+00 I .1OE3+00 3.801E+00 W-2 L3459-02 30 Ru-106 I1.231E+01 9.80E1i-00 3.30E+01 W-2 L3459-02 30 Sb-124 -1. 1OE+00 3.OOE-,00 1.101+0 I W-2 L3459-02 30 Sb- 125 -3.901E+00 2.50E3+00 9.10E-,00 W-2 L3459-02 30 Se-75 8.001E-01 1.20E+00 4.OOE+00 W-2 W3459-02 30 Zn-65 8.OOE-01 2.20E+00 7.601E+00 W-2 L3459-02 30 Zr-95 I1.70E+00 I1.80E+00 6.20E+00 W-3 L3459-03 30 AcTb-228 -2.50E+00 5.7013+00 2.001E+01
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-208
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
W-3 L3459-03 30 Ag-108m 1.IOE+00 1.OOE+00 3.40E+00 W-3 U3459-03 30 Ag-I lOm 7.OOE-01 1.70E+00 5.80E+00 W-3 U3459-03 30 Ba-140 -4.1OE+00 3.40E+00 1.30E+01 W-3 L3459-03 30 Be-7 2.00E+00 l.OOE+01 3.60E+01 W-3 L3459-03 30 Ce-141 -6.80E+00 3. 1OE+00 I.10E+01 W-3 L3459-03 30 Ce-144 5.60E+00 6.10E+00 2.10E+01 W-3 L3459-03 30 Co-57 3.10E-01 7.70E-01 2.60E+00 W-3 U3459-03 30 Co-58 7.00E-0l 1.20E+00 4.20E+00 W-3 L3459-03 30 Co-60 -9.OOE-0O 1.30E+00 4.80E+00 W-3 L3459-03 30 Cr-51 -1.00E+00 1.30E+01 4.50E+01 W-3 U3459-03 30 Cs-134 -1.70E+00 1.30E+00 5.OOE+00 W-3 L3459-03 30 Cs-137 7.OOE-01 I .30E+00 4.50E+00 W-3 U3459-03 30 Fe-59 1.90E+00 4.OOE+00 1.40E+01 W-3 U3459-03 30 - H-3 -3.60E+02 3.80E+02 1.20E+03 W-3 L3459-03 30 1-131 7.00E-01 3.90E+00 1.30E+01 W-3 U3459-03 30 K-40 1.60E+01 2.20E+01 7.40E+01 W-3 L3459-03 30 La-140 -4.80E+00 3.90E+00 1.50E+01 W-3 U3459-03 30 Mn-54 -2.00E-01 1.20E+00 4.40E+00 W-3 12459-03 30 Nb-95 -3.OOE-01 1.SOE+00 5.40E+00 W-3 U3459-03 30 Ru-103 -3.00E+00 1.30E+00 5.OOE+00 W-3 U3459-03 30 Ru-106 -1.80E+0O l.lOE+01 4.20E+01 W-3 U3459-03 30 Sb-124 -5.80E+00 3.70E+00 1.50E+01 W-3 U3459-03 30 Sb-125 4.OOE+00 3.002+00 1.10E+01 W-3 L3459-03 30 Se-75 -9.OOE-0O 1.40E+00 5.10E+00 W-3 12459-03 30 Zn-65 -9.OOE+00 3.00E+00 1.20E+01 W-3 L3459-03 30 Zr-95 5.102+00 2.20E+00 7.10E+00 W-4 U3459-04 30 AcTh-228 5.20E+00 6.70E+00 2.30E+01 W4 12459-04 30 Ag-108m -1.00E+00 1.30E+00 4.80E+00 W4 L3459-04 30 Ag-I lOim 1.70E+00 2.00E+00 7.10E+00 W4 L3459-04 30 Ba- 140 -4.OOE+00 2.80E+00 1.202+01 W4 U3459-04 30 Be-7 l.OOE+00 1.30E+01 4.702+01 W4 W3459-04 30 Ce-141 8.00E-01 2.20E+00 7.40E+00 W4 U3459-04 30 Ce-144 -8.30E+00 7.80E+00 2.80E+01 W4 12459-04 30 Co-57 -3.20E-01 9.50E-01 3.302+00 W4 U2459-04 30 Co-58 -2.OOE-01 1.40E+00 5.20E+00 W4 U3459-04 30 Co-60 -4.00E-01 1.90E+00 7.30E+00 W4 U3459-04 30 Cr-51 -1.40E+01 1.40E+01 5.002+01 W4 U3459-04 30 Cs-134 -7.00E-01 1.60E+00 6.10E+00 W-4 L3459-04 30 Cs-137 -2.00E+00 1.50E+00 5.80E+00 W-4 L3459-04 30 Fe-59 2.40E+00 3.60E+00 1.30E+01
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-209
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCilkg) (pCi/kg) (pCi/kg)
W4 L3459-04 30 H-3 9.70E+02 4.20E+02 1.20E+03 W-4 L3459-04 30 1-131 I.OOE+00 3.00E+00 l.lOE+0O W-4 L3459-04 30 K-40 3.80E+01 2.50E+01 8.40E+01 W-4 L3459-04 30 La-140 -4.60E+00 3.20E+00 1.30E+01 W-4 L3459-04 30 Mn-54 -2.10E+00 1.60E+00 6.20E+00 W-4 L3459-04 30 Nb-95 -6.60E+00 2.00E+00 8.20E+00 W4 L3459-04 30 Ru-103 -2.00E-01 1.50E+00 5.50E+00 W-4 L3459-04 30 Ru-106 5.OOE+00 1.40E3+01 5.OOE+01 WA4 L3459-04 30 Sb-124 5.60E+00 4.60E+00 1.60E+01 W-4 L3459-04 30 Sb- 125 2.80E+00 3.90E+00 1.30E+01 W-4 L3459-04 30 Se-75 -4.00E-01 1.90E+00 6.50E+00 W4 L3459-04 30 Zn-65 -2.90E1+00 3.50E+00 1.30E+01 W-4 L3459-04 30 Zr-95 -4.70E+00 2.80E+00 I.IOE+01 W-5 L3459-05 30 AcTh-228 1.14E+01 6.20E+00 2.00E+01 W-5 L3459-05 30 Ag-108m 0.00+00 1.20E+00 4.30E3+00 W-5 L3459-05 30 Ag-l [Om -1.70E1+00 2.40E1+00 8.80E+00 W-5 L3459-05 30 Ba-140 2.50E+00 2.90E+00 I.OOE+01I W-5 L3459-05 30 Be-7 0.OOE+04 1.30E+01 4.60E+01 W-5 W3459-05 30 Ce-141 1.60E+00 2.1OE+00 7.20E+00 W-5 L3459-05 30 Ce-144 -8.50E+00 7.80E+00 2.80E+01 W-5 L3459-05 30 Co-57 O.OOE+O0 1.00+00 3.50E+O0 W-5 L3459-05 30 Co-58 3.OOE-01 1.70E+00 6.20E+OO W-5 L3459-05 30 Co-60 3.80E+OO 1.90E+00 6.00E+00 W-5 L3459-05 30 Cr-51 -I.OOE+0O 1.40E+01 5.00E+01 W-5 12459-05 30 Cs-134 -2.10E+00 1.70E+00 6.60E+00 W-5 12459-05 30 Cs-137 -4.00E-01 1.70E+00 6.20E+00 W-5 12459-05 30 Fe-59 -3.40E+00 3.40E+00 1.30E+01 W-5 W3459-05 30 H-3 7.50E+02 4.10E+02 1.20E+03 W-5 W3459-05 30 1-131 -2.00E-01 3.10E+00 1.10+01 W-5 L3459-05 30 K-40 7.10E+01 3.10E+01 9.90E+0O W-5 L3459-05 30 La-140 2.90E+00 3.40E+00 1.20E+01 W-5 L3459-05 30 Mn-54 -2.90E+00 1.70E+00 6.50E+00 W-5 L3459-05 30 Nb-95 -5.OOE-01 1.70E+00 6.30E+00 W-5 L3459-05 30 Ru-103 -9.OOE-01 1.70E+00 6.002+00 W-5 L3459-05 30 Ru-106 2.OOE+00 I.50E+01 5.20E+01 W-5 12459-05 30 Sb-124 3.20E+00 4.80E+00 1.702+01 W-5 W3459-05 30 Sb-125 3.20E+00 3.90E+00 1.30E+01 W-5 L3459-05 30 Se-75 -2.00E-01 1.90E+00 6.50E+00 W-5 L3459-05 30 Zn-65 5.00E-01 4.20E+00 1.50E+01 W-5 L3459-05 30 Zr-95 -9.00-01 2.80E+00 I.OOE+01
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-210
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
W-6 U3459-06 30 AcTh-228 -3.OOE-01 4.90E+00 1.70E+01 W-6 U3459-06 30 Ag-108m 8.00E-01 l .lOE+00 3.70E+00 W-6 U2459-06 30 Ag-l1lm 2.OOE-0O 1.60E+00 5.60E+00 W-6 U3459-06 30 Ba-140 -3.OOE-0O 2.OOE+00 7.40E+00 W-6 U2459-06 30 Be-7 -2.61E+01 9.50E+00 3.70E+0I W-6 U3459-06 30 Ce-141 3.40E+00 1.90E+00 6.20E+00 W-6 12459-06 30 Ce-144 l .1OE+00 6.70E+00 2.30E+01 W-6 U3459-06 30 Co-57 1.50E-0O 8.50E-0O 2.90E+00 W-6 L3459-06 30 Co-58 -5.OOE-0O l.1OE+00 4.OOE+00 W-6 U3459-06 30 Co-60 1.70E+00 1.1 OE+00 3.70E-+00 W-6 U3459-06 30 Cr-51 l.OOE+0O .lOE+0I 3.60E+0O W-6 U3459-06 30 Cs-134 4.OOE-0O I. 1OE+00 4.OOE+00 W-6 12459-06 30 Cs-137 7.OOE-0O 1.20E+00 4.30E+00 W-6 U3459-06 30 Fe-59 -8.OOE-01 2.50E+00 9.OOE+00 W-6 U2459-06 30 H-3 7.20E+02 4.10E+02 1.20E+03 W-6 U3459-06 30 1-131 2.70E+00 2.40E+00 7.90E+00 W-6 U3459-06 30 K-40 6.70E+0O 2.10E+01 6.30E+01 W-6 U3459-06 30 La-140 -3.OOE-0O 2.30E+00 8.50E+00 W-6 U3459-06 30 Mn-54 7.OOE-0O 1.20E+00 4.20E+00 W-6 12459-06 30 Nb-95 -2.30E+00 1.20E+00 4.80E+00 W-6 U3459-06 30 Ru-103 -4.OOE-0O l.lOE+00 4.OOE+00 W-6 U3459-06 30 Ru-106 -1.50E+01 1.lOE+01 4.OOE+0O W-6 U3459-06 30 Sb-124 -2.50E+00 2.60E+00 l.OOE+01 W-6 U2459-06 30 Sb-125 7.OOE-01 3.10E+00 l.1OE+01 W-6 12459-06 30 Se-75 3.OOE-01 1.50E+00 5.OOE+00 W-6 L3459-06 30 Zn-65 1.25E+01 4.80E+00 1.50E+0O W-6 L3459-06 30 Zr-95 3.40E+00 2.10E+00 6.80E+00 W-7 L3459-07 30 AcTh-228 -2.90E+00 6.60E+00 2.40E+0O W-7 L3459-07 30 Ag-108m -I .IOE+00 1.20E+00 4.20E+00 W-7 L3459-07 30 Ag-llbm 2.30E+00 2.OOE+00 6.90E+00 W-7 L3459-07 30 Ba-140 3.30E+00 3.30E+00 1.20E+01 W-7 L3459-07 30 Be-7 -8.OOE+00 1.50E+0O 5.30E+01 W-7 L3459-07 30 Ce-141 1.70E+00 2.40E+00 8.OOE+00 W-7 L3459-07 30 Ce-144 -7.OOE-01 9.30E+00 3.20E+0O W-7 L3459-07 30 Co-57 -1.70E+00 1.20E+00 4.20E+00 W-7 12459-07 30 Co-58 -1.80E+00 1.50E+00 5.70E+00 W-7 L3459-07 30 Co-60 8.00E-0O 1.70E+00 5.90E+00 W-7 12459-07 30 Cr-51 l.OOE+0O 1.70E+01 5.70E+0O W-7 12459-07 30 Cs-134 -3.00E-01 1.50E+00 5.40E+00 W-7 U3459-07 30 Cs-137 -1.20E+00 1.40E+00 5.20E+00
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-211
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
W-7 L3459-07 30 Fe-59 5.90E+00 3.1OE+00 1.OOE+0O W-7 L3459-07 30 H-3 O.OOE+00 3.90E+02 1.20E+03 W-7 L3459-07 30 1-131 -2.00E-01 4.70E+00 1.60E+01 W-7 L3459-07 30 K-40 -2.20E+01 2.1OE+0 7.80E+01 W-7 L3459-07 30 La-140 3.70E+00 3.90E+00 1.30E+01 W-7 L3459-07 30 Mn-54 l.OOE+00 1.50E+00 5.10E+00 W-7 W3459-07 30 Nb-95 3.40E+00 1.80E+00 6.OOE+00 W-7 L3459-07 30 Ru-103 -2.60E+00 1.80E+00 6.60E+00 W-7 L3459-07 30 Ru-106 -l.OOE+01 1.40E+0O 4.90E+01 W-7 L3459-07 30 Sb-124 -6.00E-01 4. 10E+00 1.50E+01 W-7 L3459-07 30 Sb-125 3.20E+00 3.90E+00 1.30E+01 W-7 L3459-07 30 Se-75 -1.I1OE+00 1.90E+00 6.60E+00 W-7 L3459-07 30 Zn-65 -5.20E+00 3.50E+00 1.30E+01 W-7 L3459-07 30 Zr-95 2.80E+00 2.70E+00 9.20E+00 W-8 L3459-08 30 AcTh-228 3.20E+00 3.80E+00 1.40E+01 W-8 L3459-08 30 Ag-108m 1.02E+00 6.50E-0O 2.10E+00 W-8 L3459-08 30 Ag-l lOm 9.00E-01 l.OOE+00 3.40E+00 -
W-8 L3459-08 30 Ba-140 -1.70E+00 1.70E+00 6.50E+00 W-8 L3459-08 30 Be-7 6.90E+00 7.00E+00 2.30E+01 W-8 L3459-08 30 Ce- 141 1.OOE+00 1.30E+00 4.20E+00 W-8 L3459-08 30 Ce-144 -4.OOE+00 4.20E1+00 1.50E+01 W-8 L3459-08 30 Co-57 -I.OOE-02 5.40E-01 1.80E+00 w-8 L3459-08 30 Co-58 -9.60E-0O 7.50E-01 2.70E+00 W-8 L3459-08 30 Co-60 6.00E-02 8.40E-01 2.90E+00 W-8 L3459-08 30 Cr-51 -5.80E+00 8.00EOE00 2.80E+01 W-8 L3459-08 30 Cs-134 1.12E+00 7.50E-01 2.50E+00 w-8 L3459-08 30 Cs-137 -5.30E-01 7.50E-0O 2.70E+00 w-8 L3459-08 30 Fc-59 7.OOE-01 1.70E+00 5.70E+00 W-8 L3459-08 30 H-3 9.OOE+0O 3.90E+02 1.20E+03 w-8 L3459-08 30 1-131 1.70E+00 2.50E+00 8.50E+00 W-8 L3459-08 30 K-40 3.20E+0O 1.40E+0O 4.40E+01 w-8 L3459-08 30 La-140 -1.90E+00 2.00E+00 7.40E+00 W-8 L3459-08 30 Mn-54 3.60E-0O 7.70E-01 2.60E+00 W-8 L3459-08 30 Nb-95 -3.50E+00 1.20E+00 4.30E+00 W-8 U3459-08 30 Ru-103 -3.04E+00 8.70E-0I 3.30E+00 W-8 L3459-08 30 Ru-106 -8.1OE+00 7.50E+00 2.70E+01 W-8 L3459-08 30 Sb- 124 1.40E+00 1.90E+00 6.60E+00 W-8 L3459-08 30 Sb-125 0.OOE+00 2.00E+00 6.80E+00 W-8 L3459-08 30 Se-75 5.OOE-0O l.OOE+00 3.40E+00 w-8 L3459-08 30 Zn-65 -9.00E-01 1.60E+00 5.80E+00
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-212
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
W-8 L3459-08 30 Zr-95 0.OOE+00 1.40E+00 4.70E+00 W-9 L3459-09 30 AcTh-228 1.80E+00 4.10E+00 1.40E+0O W-9 L3459-09 30 Ag-108m 9.OOE-02 6.OOE-01 2.OOE+00 W-9 L3459-09 30 Ag-lOrm 4.70E-01 9.30E-01 3.20E+00 W-9 L3459-09 30 Ba-140 9.OOE-01 1.60E+00 5.60E+00 W-9 L3459-09 30 Be-7 8.90E+00 6.50E+00 2.20E+0O W-9 L3459-09 30 Ce-141 -2.70E+00 1.50E+00 5.30E+00 W-9 L3459-09 30 Ce-144 4.OOE-01 3.70E+00 1.30E+0I W-9 L3459-09 30 Co-57 4.20E-01 6.70E-01 2.20E+00 W-9 L3459-09 30 Co-58 -6.60E-01 7.40E-01 2.70E+00 W-9 L3459-09 30 Co-60 -7.10E-01 8.40E-01 3.OOE+00 W-9 L3459-09 30 Cr-51 -6.80E+00 7.60E+00 2.70E+01 W-9 L3459-09 30 Cs-134 -5.40E-01 7.60E-01 2.70E+00 W-9 L3459-09 30 Cs-137 -I.SOE+00 7.50E-01 2.70E+00 W-9 L3459-09 30 Fe-59 1.30E+00 1.60E+00 5.40E+00 W-9 L3459-09 30 H-3 1.40E+02 4.00E+02 1.20E+03 W-9 L3459-09 30 1-131 4.30E+00 3.OOE+00 9.80E+00 W-9 L3459-09 30 K-40 -4.OOE+00 1.50E+01 5.OOE+01 W-9 L3459-09 30 La-140 I.OOE+00 1.90E+00 6.40E+00 W-9 L3459-09 30 Mn-54 -9.60E-01 6.90E-01 2.50E+00 W-9 L3459-09 30 Nb-95 3.OOE-01 9.OOE-01 3.10E+00 W-9 L3459-09 30 Ru-103 9.OOE-02 8.OOE-01 2.80E+00 W-9 L3459-09 30 Ru-106 1.78E+01 6.70E+00 2.10E+01 W-9 L3459-09 30 Sb-124 -2.1OE+00 2.1OE+00 7.60E+00 w-g L3459-09 30 Sb-125 -1.80E+00 1.80E+00 6.30E+00 W-9 L3459-09 30 Se-75 -1.21E+00 7.70E-01 2.70E+00 W-9 L3459-09 30 Zn-65 -2.30E+00 1.60E+00 5.80E+00 W-9 L3459-09 30 Zr-95 2.OOE-01 1.30E+00 4.60E+00 W-1O L3459-10 30 Aclh-228 9.20E+00 5.10E+00 2.OOE+0O W-1O L3459-10 30 Ag-108m -2.OOE-01 1.IOE+00 3.70E+00 W-10 L3459-10 30 Ag-lOnm O.OOE+00 2.OOE+00 7.20E+00 W-10 L3459-10 30 Ba-140 -I.OOE+00 3.30E+00 1.30E+0O W-IO L3459-10 30 Be-7 3.OOE+00 1.20E+01 4.10E+0O W-1O L3459-10 30 Ce-141 -5.40E+00 2.1OE+00 7.60E+00 W-lo L3459-10 30 Ce-144 -8.70E+00 7.OOE+00 2.50E+0O W-1O L3459-10 30 Co-57 -1.20E+00 8.30E-01 2.90E+O0 D-213
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCilkg) (pCi/kg) (pCilkg) w-Io W3459-10 30 Cs-137 3.00E-01 1.30E+00 4.70E+00 w-1o W3459-10 30 Fe-59 1.20E+00 3.40E+0O 1.20E+01 W-10 W3459-10 30 H-3 1.50E+02 3.90E+02 1.202+03 W-10 W3459-10 30 1-131 -3.70E+00 4.00E+00 I .40E+0O W-10 L3459-10 30. K-40 9.00E+00 2.30E+0O 8.00E+0O W-10 L3459-10 30 La-140 -1.20E+00 3.80E+00 1.40E+0O W-10 L3459-10 30 Mn-54 -4.00E-01 1.40E+00 5.OOE+00 W-10 L3459-10 30 Nb-95 -4.90E+00 2.70E+00 l.OOE+01 W-10 L3459-10 30 Ru-103 -3.80E+00 1.40E+00 5.60E+00 W-10 L3459-10 30 Ru-106 1.50E+01 1.30E+01 4.20E+01 W-10 L3459-10 30 Sb-124 1.30E+00 4. 1OE+00 I .50E+0I W-10 L3459-10 30 Sb-125 -3.90E+00 3.40E+00 1.20E+0O W-10 W3459-10 30 Se-75 1.50E+00 1.60E+00 5.50E+00 W-10 W3459-10 30 Zn-65 1.40E+00 6.30E+00 2.20E+01 W-10 W3459-10 30 Zr-95 3.80E+00 2.40E+00 8.10E+00 W-1I 12459-11 30 AcTh-228 9.OOE-0I 5.50E+00 L.90E+01 W-11 L3459-11 30 Ag-108m 2.20E-01 9.50E-01 3.30E+00 W-11 L3459-11 30 Ag-l lOm 1.20E+00 1.80E+00 6.10E+00 W-Il W3459-11 30 Ba- 140 -2.70E+00 3.40E+00 1.30E+01 W-l1 L3459- 11 30 Be-7 -7.OOE+00 1.1OE+01 3.90E+01 W-1l L3459-1 I 30 Ce- 141 9.OOE-01 l.90E+00 6.50E+00 W-11 L3459-1 I 30 Ce-144 3.80E+00 6.20E+00 2.10E+0O W-11 12459-11 30 Co-57 -3.90E-0I 7.70E-0I 2.60E+00 W-11 W3459-11 30 Co-58 -2.50E+00 1.30E+00 5.00E+00 W-ll W3459-11 30 Co-60 1.90E+00 1.60E+O00 5.20E+00 W-ll W3459-11 30 Cr-51 2.00E+00 1.30E+0O 4.40E+01 W-ll W3459-11 30 Cs-134 8.00E-0O 1.30E+00 4.50E+00 W-1I L3459-11 30 Cs- 137 LOOE-0I 1.20E+-O 4.30E+00 W-1l L3459-11 30 Fe-59 -4.40E+00 3.OOE+00 1.20E+0O W-1l L3459-1 1 30 H-3 -1.40E+02 3.90E+02 1.20E+03 W-11 L3459- 11 30 1-131 I.90E+00 4.30E+00 1.50E+01 W-ll L3459-11 30 K-40 -I.IOE+01 I.90E+0O 6.80E+0O W-ll W3459-11 30 La- 140 -3.0IE+O0 3.90E+00 1.50E+01 W-11 L3459-11 30 Mn-54 1.20E+00 I .30E+00 4.50E+00 W-ll W3459-11 30 Nb-95 -I.OOE-0O 1.40E+00 4.90E+00 W-Il L3459-1 1 30 Ru-103 1.30E+00 1.40E+00 4.80E+00 W-1l L3459- 11 30 Ru-106 -1.60E+0O 1.20E+01 4.30E+01 W-1l L3459- 11 30 Sb-124 -6.40E+00 3.90E+00 1.60E+01 W-l1 L3459-11 30 Sb-125 6.20E+O0 2.90E+00 9.40E+00 W-1l L3459-1 1 30 Se-75 7.OOE-0O 1.50E+00 5.10E+00
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-214
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg) w-I1 L3459-11 30 Zn-65 -6.80E+00 2.90E+00 1.20E+01 W-ll L3459-11 30 Zr-95 9.OOE-01 2.30E+00 7.90E+O0 W-12 L3459-12 30 AcTh-228 -7.OOE-01 4.20E+00 1.50E+0I W-12 L3459-12 30 Ag-108m -6.50E-01 8.70E-01 3.1OE+00 W-12 U3459-12 30 Ag-I lOm 1.90E+00 1.50E+00 4.90E+00 W-12 L3459-12 30 Ba-140 -8.OOE-01 2.20E+00 8.20E+00 W-12 L3459-12 30 Be-7 1.04E+01 8.60E+00 2.90E+0O W-12 L3459-12 30 Ce-141 -I.OOE-01 1.70E+00 5.90E+00 W-12 L3459-12 30 Ce-144 -1.90E+00 5.90E+00 2.OOE+0O W-12 L3459-12 30 Co-57 2.OOE-02 7.50E-01 2.60E+00 W-12 L3459-12 30 Co-58 -6.OOE-01 1.lOE+00 3.90E+00 W-12 L3459-12 30 Co-60 1.80E+00 l.OOE+00 3.40E+00 W-12 L3459-12 30 Cr-51 -I.OOE+00 1.20E+01 4.OOE+01 W-12 L3459-12 30 Cs-134 6.OOE-0O l.OOE+O0 3.50E+00 W-12 L3459-12 30 Cs-137 -1.20E+O0 1.1OE+O0 3.90E+O0 W-12 L3459-12 30 Fe-59 -4.20E+O0 2.20E+00 8.50E+O0 W-12 L3459-12 30 H-3 -1.50E+02 3.90E+02 1.20E+03 W-12 L3459-12 30 1-131 5.50E+O0 3.60E+00 1.20E+0I W-12 L3459-12 30 K-40 4.10E+0O 1.70E+01 5.50E+O1 W-12 L3459-12 30 La-140 -9.OOE-0O 2.60E+00 9.40E+O0 W-12 L3459-12 30 Mn-54 7.OOE-OI l.OOE+00 3.50E+O0 W-12 L3459-12 30 Nb-95 -1.60E+O0 2.OOE+00 7.20E+O0 W-12 L3459-12 30 Ru-103 -1.70E+O0 l.lOE+00 4.10E+O0 W-12 L3459-12 30 Ru-106 -I.OOE-0O 9.80E+00 3.40E+O1 W-12 L3459-12 30 Sb-124 -4.60E+00 2.80E+00 1.IOE+O1 W-12 L3459-12 30 Sb-125 l.OOE+O0 2.80E+00 9.SOE+O0 W-12 L3459-12 30 Se-75 l.OOE+OO 1.30E+00 4.40E+O0 W-12 L3459-12 30 Zn-65 5.10E+O0 4.50E+00 1.50E+01 W-12 L3459-12 30 Zr-95 2.70E+00 1.80E+00 5.80E+00 W-13 L3459-13 30 AcTh-228 1.OIE+0O 3.60E+00 1.1OE+01 W-13 L3459-13 30 Ag-108m -1.06E+00 8.10E-01 2.90E+O0 W-13 L3459-13 30 Ag-Il0m 9.OOE-0I l.1OE+O0 3.80E+00 W-13 L3459-13 30 Ba-140 3.50E+00 2.20E+00 7.30E+O0 W-13 L3459-13 30 Be-7 -1.08E+OI 7.80E+00 2.80E+0I W-13 L3459-13 30 Ce-141 l.OOE+00 1.60E+00 5.30E+00 W-13 L3459-13 30 Ce-144 -7.80E+00 5.IOE+00 1.80E+0O W-13 L3459-13 30 Co-57 -1.35E+00 8.10E-01 2.80E+00 W-13 L3459-13 30 Co-58 -7.60E-0O 9.50E-01 3.50E+00 W-13 L3459-13 30 Co-60 -6.OOE-0O l.lOE+O0 3.90E+00 W-13 L3459-13 30 Cr-51 -2.OOE+O0 l.OOE+OI 3.50E+OI
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-215
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
W-13 L3459-13 30 Cs-134 -1.97E+00 8.90E-01 3.50E+00 W-13 L3459-13 30 Cs-137 -6.90E-01 9.80E-01 3.50E+00 W-13 L3459-13 30 Fe-59 2.30E+00 2.10E+00 7.10E+00 W-13 L3459-13 30 H-3 6.00E+01 3.90E+02 1.20E+03 W-13 L3459-13 30 1-131 -2.40E+00 3.60E+00 1.30E+01 W-13 L3459-13 30 K-40 4.00E+00 1.60E+01 5.60E+01 W-13 L3459-13 30 La-140 4.00E+00 2.50E+00 8.40E+00 W-13 L3459-13 30 Mn-54 -1.22E+00 8.90E-01 3.30E+O0 W-13 L3459-13 30 Nb-95 -2.OOE-01 l.IOE+00 4.00E+00 W-13 L3459-13 30 Ru-103 -8.00E-01 I.IOE+00 3.80E+00 W-13 L3459-13 30 Ru-106 7.60E+00 8.30E+00 2.80E+01 W-13 L3459-13 30 Sb-124 -1.20E+00 2.50E+00 9.302+00 W-13 L3459-13 30 Sb-125 -1.IOE+00 2.60E+00 9.00E+00 W-13 L3459-13 30 Se-75 -3.00E-01 I.IOE+00 3.602+00 W-13 13459-13 30 Zn-65 6.70E+00 4.1OE+00 1.30E+01 W-13 L3459-13 30 Zr-95 2.60E+00 1.80E+00 6.IOE+00 W-14 L3459-14 30 AcTh-228 -2.50E+00 5.30E+00 1.90E+01 W-14 L3459-14 30 Ag-108m 1.90E1+00 9.90E-01 3.202+00 W-14 L3459-14 30 Ag-l1lm -9.OOE-01 1.80E+00 6.40E+00 W-14 L3459-14 30 Ba-140 -5.20E+00 3.00E+00 1.20E+01 W-14 L3459-14 30 Be-7 -I.IOE+01 l.IOE+01 4.IOE+0O W-14 L3459-14 30 Ce-141 -1.IOE+00 4.1OE+00 1.40E+0O W-14 L3459-14 30 Ce-144 -2.40E+00 8.10E+00 2.80E+01 W-14 L3459-14 30 Co-57 -1.IOE+00 I.IOE+00 3.60E+00 W-14 L3459-14 30 Co-58 -2.OOE-01 1.40E+00 5.OOE+00 W-14 L3459-14 30 Co-60 -1.50E+00 1.40E+00 5.30E+00 W-14 L3459-14 30 Cr-51 -7.OOE+00 1.40E+01 4.70E+01 W-14 L3459-14 30 Cs-134 I.OOE+00 1.50E+00 5.00E+00 W-14 L3459-14 30 Cs-137 -1.00-01 1.30E+00 4.60E+00 W-14 L3459-14' 30 Fe-59 6.30E+00 3.10E+00 9.802+00 W-14 L3459-14 30 H-3 3.60E+02 4.00E+02 1.20E+03 W-14 L3459-14 30 1-131 6.70E+00 4.30E+00 1.40E+01 W-14 L3459-14 30 K-40 1.80E+01 2.20E+01 7.40E+01 W-14 L3459-14 30 La-140 -5.90E+00 3.50E+00 1.40E+01 W-14 L3459-14 30 Mn-54 -2.00E-01 1.30E+00 4.50E+00 W-14 L3459-14 30 Nb-95 -1.20E+00 1.60E+00 5.80E+00 W-14 L3459-14 30 Ru-103 -2.60E+00 1.60E+00 5.80E+00 W-14 L3459-14 30 Ru-106 -3.202+01 1.10+01 4.202+01 W-14 L3459-14 30 Sb-124 -1.20E+00 3.60E+00 1.30E+01 W-14 L3459-14 30 Sb-125 -1.60E+00 3.20E+00 1.IOE+0O
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-216
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
W-14 L3459-14 30 Se-75 6.OOE-01 1.80E3+00 5.901E+00 W-14 L3459-14 30 Zn-65 -8.50E+00 3.OOE+O0 1.201E+01 W-14 L3459-14 30 Zr-95 1.30E+O00 2.30E+00 8.001E+00
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-217
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg) w-I L4188-01 43 Ac11-228 -1.10E+00 4.80E+00 1.70E+0O w-1 L4188-01 43 Ag-108m -4.00E-01 1.IOE+00 4.00E+00 w-1 L4188-01 43 Ag-llbm -2.00E-O1 1.70E+00 6.10OE+00 w-1 L4188-01 43 Ba-140 3.30E+00 2.70E+00 9.OOE+00 w-l L4188-01 43 Be-7 3.00E+00 1.lOE+01 3.80E+01 w-I L4188-01 43 Ce-141 -2.30E+00 2.30E+00 8. IOE+00 w-1 L4188-01 43 Ce-144 7.20E+00 7.60E+00 2.50E+01 w-1 L4188-01 43 Co-57 1.70E-01 9.20E-Ot 3.20E+00 w-1 L4188-01 43 Co-58 -1.30E+00 1.20E+00 4.60E+00 w-1 L4188-01 43 Co-60 -4.OOE-01 1.20E+00 4.60E+00 w-I L4188-01 43 Cr-51 7.OOE+OO 1.30E+01 4.30E+01
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-218
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
W-1 L4188-01 43 Cs-134 -1.00E-01 1.40E+00 5.00E+00 W-l L4188-01 43 Cs-137 3.00E-01 1.30E+00 4.50E+00 W-l LU188-01 43 Fe-59 I.IOE+00 2.90E+00 1.OOE+0O W- L4188-01 43 H-3 -1.I10+02 5.30E+02 1.60E+03 W- L4188-01 43 1-131 1.50E+00 4.30E+00 1.50E+01 W-l L188-01 43 K-40 2.90E+01 1.90E+01 6.40E+01 W-l LU188-01 43 La-140 3.80E+00 3.10E+00 I.OOE+0I W-1 L4188-01 43 Mn-54 -I.OOE-01 1.20E+00 4.30E+00 W-l L188-01 43 Nb-95 -1.20E+00 1.60E+00 5.70E+00 W-l L4188-01 43 Ru-103 -2.1OE+00 1.50E+00 5.50E+00 W-l L4188-01 43 Ru-106 1.20E+01 1.20E+01 4.10E+01 W-1 L4188-01 43 Sb-124 -3.60E+00 3.30E+00 1.30E+01 W- L4188-01 43 Sb-125 -4.10E+00 3.10E+00 1.20E+01 W-1 L4188-01 43 Se-75 -2.50E+00 1.60E+00 5.60E+00 W-l UA188-01 43 Zn-65 -3.50E+00 3.20E+00 1.20E+01 W-1 LU188-01 43 Zr-95 I.OOE-0I 2.20E+00 7.80E+00 W-2 L4188-02 43 AcTh-228 -2.OOE-01 5.00E+00 1.80E+01 W-2 L4188-02 43 Ag-108m 1.30E+00 I.OOE+O0 3.40E+00 W-2 L4188-02 43 Ag-l1lm -3.00E-01 1.40E+00 5.20E+00 W-2 L4188-02 43 Ba-140 -1.50E+00 2.20E+00 8.80E+00 W-2 LU188-02 43 Be-7 -4.OOE+00 1.00E+0 3.60E+01 W-2 L4188-02 43 Ce-141 -I.OOE-O1 1.30E+00 4.502+00 W-2 L4188-02 43 Ce-144 1.08E+01 6.20E+00 2.00E+01 W-2 L4188-02 43 Co-57 -1;63E+00 7.90E-01 2.90E+00 W-2 L188-02 43 Co-58 -1.50E+00 1.20E+00 4.60E+00 W-2 L4188-02 43 Co-60 3.00E-01 1.10E+00 4.1OE+00 W-2 L4188-02 43 Cr-51 8.00E+00 1.20E+01 4.10E+01 W-2 L4188-02 43 Cs-134 1.50E+00 1.IOE+00 3.60E+00 W-2 L4188-02 43 Cs-137 6.OOE-01 1.20E+00 4.10E+00 W-2 L4188-02 43 Fe-59 -3.00E-01 2.60E+00 9.50E+00 W-2 14188-02 43 H-3 3.70E+02 5.40E+02 1.60E+03 W-2 U4188-02 43 1-131 8.00E-01 3.80E+00 1.30E+0O W-2 L4188-02 43 K-40 -4.OOE+00 1.80E+01 6.50E+01 W-2 L4188-02 43 La-140 -1.80E+00 2.50E+00 I.OOE+01 W-2 L4188-02 43 Mn-54 -1.50E+00 1.20E+00 4.50E+00 W-2 LA188-02 43 Nb-95 -1.80E+00 1.40E+00 5.40E+00 W-2 LA188-02 43 Ru-103 -3.50E+00 1.30E+00 5.00E+00 W-2 L4188-02 43 Ru-106 4.00E+00 1.10E+01 4.00E+01 W-2 LA188-02 43 Sb-124 7.20E+00 3.20E+00 9.70E+00 W-2 LA188-02 43 Sb-125 -6.50E+00 2.90E+00 1.10E+01
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-219
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
W-2 L4188-02 43 Se-75 2. 10E+00 1.20E+00 4.00E+00 W-2 L4188-02 43 Zn-65 6.00E-01 3.20E+00 1.1OE+01 W-2 L4188-02 43 Zr-95 3. 10E+00 2.202+00 7.40E+00 W-3 L4188-03 43 AcTh-228 6.20E+OO 3.20E+00 1.OOE+01 W-3 L4188-03 43 Ag-108m 9.70E-01 7.00E-0O 2.30E+00 W-3 L4188-03 43 Ag-l lOm 1.OOE+00 1.lOE+00 3.70E+00 W-3 L4188-03 43 Ba-140 -1.70E+00 1.90E+0O 7.10E+00 W-3 L4188-03 43 Be-7 -5.70E+00 7.40E+00 2.60E+01 W-3 L4188-03 43 Ce-141 -1.20E+00 1.40E+00 4.90E+00 W-3 L4188-03 43 Ce-144 -6.OOE-0O 4.60E+00 1.60E+01 W-3 L4188-03 43 Co-57 -1.20E-01 5.90E-01 2.00E+00 W-3 L4188-03 43 Co-58 -1.43E+00 8.70E-01 3.20E+00 W-3 L4188-03 43 Co-60 -1.60E-0I 8.40E-01 3.00E+00 W-3 L4188-03 43 Cr-51 6.80E+00 9.50E+OO 3.20E+01 W-3 L4188-03 43 Cs-134 8.70E-01 8.20E-01 2.80E+00 W-3 L4188-03 43 Cs-137 -1.91E+00 9.30E-0O 3.40E+00 W-3 L4188-03 43 Fe-59 3.80E+00 2.OOE+00 6.60E+00 W-3 L4188-03 43 H-3 8.00E+0O 5. 10E+02 1.60E+03 W-3 L4188-03 43 1-131 -3.00E-01 2.90E+00 9.80E+00 W-3 L4188-03 43 K-40 -3.00E+00 1.50E+01 5.20E+01 W-3 L4188-03 43 La-140 -2.00E+00 2.20E+00 8.10OE+00 W-3 L4188-03 43 Mn-54 3.10E-01 8.10E-01 2.80E+00 W-3 L4188-03 43 Nb-95 -8.00E-0l 1.IOE+00 4.10E+00 W-3 L4188-03 43 Ru-103 -2. 10E+00 l.OOE+00 3.80E+00 W-3 L4188-03 43 Ru-106 8.50E+00 8.50E+00 2.90E+0O W-3 L4188-03 43 Sb-124 -I.OOE+00 2.20E+00 8.30E+00 W-3 L4188-03 43 Sb-125 -5.OOE-01 2. 10E+00 7.40E+00 W-3 L4188-03 43 Se-75 -1.79E+00 9.60E-01 3.40E+00 W-3 L4188-03 43 Zn-65 9.70E+00 3.40E+00 1.10+01 W-3 L4188-03 43 Zr-95 3.00E-01 1.60E+00 5.70E+00 W4 L4188-04 43 AcTh-228 2.50E+00 3.20E+00 1.40E+01 W-4 L4188-04 43 Ag-108m 1.21E+00 7.50E-01 2.50E+00 W4 UA188-04 43 Ag-i lOm -6.OOE-01 1.30E+00 4.50E+00 W4 L4188-04 43 Ba-140 -1.302+00 2.00E+00 7.50E+00 W4 L4188-04 43 Be-7 3.40E+00 8.20E+00 2.80E+01 W4 L4188-04 43 Ce-141 -1.50E+00 1.80E+00 6.OOE+00 W4 L4188-04 43 Ce-144 -6.60E+00 5.20E+00 1.80E+01 W-4 [4188-04 43 Co-57 8.00E-02 6.90E-01 2.30E+00 W4 L4188-04 43 Co-58 I.OOE-0I l.OOE+00 3.60E+00 W-4 L4188-04 43 Co-60 1.60E-01 9.70E-01 3.40E+00
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-220
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
W-4 L4188-04 43 Cr-51 5.10E+00 9.60E+00 3.20E+01 W.4 L4188-04 43 Cs-134 2.20E-01 9.50E-01 3.30E+00 W-4 L4188-04 43 Cs-137 8.OOE-02 9.40E-01 3.20E+00 W-4 L4188-04 43 Fe-59 -2.OOE-01 2.40E+00 8.40E+00 W-4 L4188-04 43 H-3 L.OOE+03 5.50E+02 1.60E+03 W4 L4188-04 43 1-131 -5.40E+00 3.OOE+00 l.lOE+01 W-4 L4188-04 43 K-40 4.OOE+01 1.50E+01 4.70E+01 W-4 L4188-04 43 La-140 -1.50E+00 2.30E+00 8.60E+00 W-4 L4188-04 43 Mn-54 -1.38E+00 8.80E-01 3.20E+00 W.4 L4188-04 43 Nb-95 I.OOE-0O 1.20E+00 4.10E+00 W-4 L4188-04 43 Ru-103 3.OOE-01 L.OOE+00 3.40E+00 W4 L4188-04 43 Ru-106 -6.70E+00 9.OOE+00 3.20E+01 W4 L4188-04 43 Sb-124 -1.70E+00 2.30E+00 8.70E+00 W4 L4188-04 43 Sb-125 6.70E+00 2.30E+00 7.40E+00 W4 L4188-04 43 Se-75 -8.00E-01 1.20E+00 4.10E+00 W4 L4188-04 43 Zn-65 -3.80E+00 2.90E+00 1.IOE+0O WA4 L4188-04 43 Zr-95 2.30E+00 1.40E+00 4.60E+00 W-5 L4188-05 43 AcTh-228 -1.40E+00 4.10E+00 1.40E+01 W-5 L4188-05 43 Ag-108m 1.30E-01 7.10E-01 2.40E+00 W-5 L4188-05 43 Ag-llbm -7.OOE-01 I.IOE+00 4.00E+00 W-5 L4188-05 43 Ba-140 I.OOE+00 1.70E+00 6.OOE+00 W-5 L4188-05 43 Be-7 -1.38E+01 7.50E+00 2.70E+01 W-5 L4188-05 43 Ce-141 1.70E+00 2.10E+00 6.90E+00 W-5 L4188-05 43 Ce-144 2.30E+00 4.70E+00 1.60E+01 W-5 L4188-05 43 Co-57 -4.20E-01 5.90E-01 2.00E+00 W-5 L4188-05 43 Co-58 -5.OOE-02 9.30E-01 3.30E+00 W-5 14188-05 43 Co-60 -4.90E-01 8.40E-01 3.10E+00 W-5 L4188-05 43 Cr-51 -6.70E+00 9.50E+00 3.30E+01 W-5 14188-05 43 Cs-134 -5.OOE-02 8.60E-01 3.OOE+00 W-5 L4188-05 43 Cs-137 -4.80E-01 9.30E-01 3.30E+00 W-5 L4188-05 43 Fe-59 5.20E+00 2.OOE+00 6.20E+00 W-5 L4188-05 43 H-3 6.20E+02 5.50E+02 1.60E+03 W-5 L4188-05 43 1-131 3.00E-01 3.OOE+00 I.OOE+0I W-5 14188-05 43 K-40 8.00E+01 1.50E+01 4.40E+01 W-5 L4188-05 43 La-140 I.IOE+00 2.OOE+00 6.80E+00 W-5 14188-05 43 Mn-54 1.40E-01 7.80E-01 2.70E+00 W-5 L4188-05 43 Nb-95 -2.30E+00 I.IOE+00 4.10E+00 W-5 L4188-05 43 Ru-103 -9.20E-01 9.90E-01 3.50E+00 W-5 LA188-05 43 Ru-106 6.00E+00 8.20E+00 2.80E+01 W-5 L4188-05 43 Sb-124 I.OOE+00 2.20E+00 7.80E+00
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-221
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
W-5 L4188-05 43 Sb-125 -2.10E+00 2.30E+00 8.00E+00 W-S L4188-05 43 Se-75 -1.50E-01 9.70E-01 3.30E+00 W-5 L4188-05 43 Zn-65 -5.00E-OI 1.80E+OO 6.30E+00 W-5 L4188-05 43 Zr-95 -l.0013+00 1.70E+00 6.20E+00 W-6 L4188-06 43 AcTh-228 -4.70E+OO 4.101E+OO 1.50E+OI W-6 LA188-06 43 Ag- 108m 1.72E+00 7.20E-OI 2.30E+00 W-6 L4188-06 43 Ag-llOm 2. IOE+00 1.30E+00 4.20E+00 W-6 LA188-06 43 Ba-140 -2.OOE-0O 2.00E+00 7. IOE+00 W-6 LA1 88-06 43 Be-7 -1.02E+0O 8.1OE+00 2.90E+01 W-6 LlA88-06 43 Ce-141 -3.00E-0I 1.50E+00 5.00E+00 W-6 L4188-06 43 Ce-144 -1.1 IE+0O 4.90E+00 1.80E+OI W-6 L4188-06 43 Co-57 5.40E-01 6.50E-01 2.20E+00 W-6 L4188-06 43 Co-58 -L.OOE-0O 8.50E-01 3.00E+00 W-6 L4188-06 43 Co-60 1.30E+0O l.lOE+00 3.60E+00 W-6 L4188-06 43 Cr-51 -1.90E+0O 9.40E3+00 3.20E+OI W-6 LA188-06 43 Cs-134 5.OOE-OI 8.80E-OI 3.00E+00 W-6 L4A 88-06 43 Cs-137 -9.60E-0O 9.80E-0O 3.50E+00 W-6 LA188-06 43 Fe-59 4.OOE-OI 2.00E+00 7.10+00 W-6 LA188-06 43 H-3 -2.OOE+02 5.20E+02 1.60E+03 W-6 LA188-06 43 1-131 2.90E+00 3.00E+00 I.OOE+0O W-6 LA188-06 43 K-40 4.30E+01 1.60E+0O 5.10E+01 W-6 LA1 88-06 43 LA-140 -3.OOE-OI 2.30E+00 8.20E+00 W-6 LA188-06 43 Mn-54 2.10E-0O 8.50E-ol 3.00E+00 W-6 L1A 88-06 43 Nb-95 -1 .60E+00 1.40E+00 4.80E+00 W-6 LA188-06, 43 Ru-103 l.OOE-01 l.IOE+00 3.70E+00 W-6 LA188-06 43 Ru-106 9.60E+00 8.40E+00 2.80E+01 W-6 L4188-06 43 Sb- 124 4.90E+OO 2.20E+00 6.70E+00 -
W-6 LA188-06 43 Sb-125 6.00E-01 2.30E+00 8.00E+00 W-6 LA1 88-06 43 Se-75 -2.40E+00 1.20E+00 4.10E+00 W-6 LA188-06 43 Zn-65 1.70E+00 2.60E+00 8.70E+00 W-6 LA188-06 43 Zr-95 -2.80E+00 1.50E1+O0 5.80E+00 W-7 LA188-07 43 AcTh-228 0.OOE+00 2.60E+00 8.80E+00 W-7 LA1 88-07 43 Ag-108m 3.80E-01 4.70E-01 1.60E+00 W-7 LA188-07 43 Ag-l lOm -8.70E-OI 7.OOE-0O 2.50E+00 W-7 LA188-07 43 Ba-140 -4.00E-0O I.OOE+00 3.70E+00 W-7 L4188-07 43 Be-7 -6.00E+00 5.00E+00 1.70E+01 W-7 LA188-07 43 Ce-141 -4.00E-01 9.40E-01 3.20E+00 W-7 LA188-07 43 Ce-144 4.30E+00 3. tOE+00 1.002+01 W-7 LA188-07 43 Co-57 -1.40E-0O 4.002-01 1.40E+00 W-7 LA188-07 43 Co-58 -6.00E-02 5.90E-01 2.00E+00
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-222
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
W-7 L4188-07 43 Co-60 -6.40E-01 5.80E-01 2.101E+00 W-7 L4188-07 43 Cr-51 7.70E+00 6.OOE+00 2.OOE+01 W-7 L4188-07 43 Cs-134 1.35E+00 6.10O-01 2.001E+00 W-7 L4188-07 43 Cs-137 1.90E-01 6.301E-01 2. 101+00 W-7 L4188-07 43 Fe-59 7.00E-01 1.20E+00 4.20E+00 W-7 L4188-07 43 H-3 2.60E+02 5.501E+02 1.60E+03 W-7 L4188-07 43 1-131 1.60E+00 1.701E+00 5.60E+00 W-7 L4188-07 43 K-40 -1.OOE+00 LOOE1+01 3.501E+01 W-7 L4188-07 43 La-140 -5.00E-01 1.20E+00 4.20E+00 W-7 L4188-07 43 Mn-54 -1.OIE+00 5.40E-01 2.OOE+00 W-7 L4188-07 43 Nb-95 -3.50E-01 6.80E-01 2.40E+O00 W-7 L4188-07 43 Ru-103 -1.69E+00 6.60E-01 2.40E+00 W-7 L4188-07 43 Ru-106 2.40E+00 5.90E+00 2.001E+01 W-7 L4188-07 43 Sb-124 -1.OOE+00 1.50E+00 5.50E+00 W-7 L4188-07 43 Sb-125 -1.70E+00 1.50E3+00 5.301E+00 W-7 L4188-07 43 Se-75 2.20E-01 6.30E-01 2.10E+00 W-7 L4188-07 43 Zn-65 1.IOE+00 1.70E+00 5.701E+00 W-7 L4188-07 43 Zr-95 -11.OOE-O1 1.20E+00 4.20E+00 W-8 L4188-08 43 AcTh-228 -1.90E+00 4.501E+00 1.60E+01 W-8 L4188-08 43 Ag-108m -9.00E-01 6.901E-01 2.40E+00 W-8 L4188-08 43 Ag-I lOm 1.OOE-01 1.40E+00 4.70E+00 W-8 L4188-08 43 Ba-140 1.OOE+00 2. 10t+00 7.401E+00 W-8 L4188-08 43 Be-7 -3.50E+00 8.40E+00 2.90E+01 W-8 L4188-08 43 Ce-141 -2.50E+00 I.901E+00 6.30E3+00 W-8 U4188-08 43 Ce-144 4.OOE+00 5.60E+00 I1.90E+01 W-8 L4188-08 43 Co-57 -7.60E-01 7.401E-01 2.501E+00 W-8 L4188-08 43 Co-58 -1.28E+O0 9.OOE-01 3.30E+00 W-8 L4188-08 43 Co-60 1.91E+00 9.OOE-01 2.90E+00 W-8 L4188-08 43 Cr-51 -1.53E+01 9.70E+00 3.40E+01 W-8 L4188-08 43 Cs-134 1.72E+00 9.20E-01 3.OOE+00 W-8 L4188-08 43 Cs-137 -3.54E+00 9.30E-01 3.50E+00 W-8 L4188-08 43 Fe-59 1.lOE+00 1.90E+00 6.60E+00 W-8 L4188-08 43 H-3 -1. IOE+02 5.40E+02 1.60E+i03 W-8 L4188-08 43 1-131 4.OOE+00 2.70E+00 8.90E+00 W-8 L4188-08 43 K-40 -9.OOE+00 1.50E+01 5.30E+01 W-8 L4188-08 43 La-140 1.OE+00 2.501E+00 8.50E+00 W-8 L4188-08 43 Mn-54 -7.30E-0O 9.60E-01 3.40E+00 W-8 L4188-08 43 Nb-95 1.40E+00 1.IOE+00 3.50E+00 W-8 L4188-08 43 Ru-103 -6.OOE-0I 1.OOE+00 3.50E-e00 W-8 L4188-08 43 Ru-106 -9.OOE-01 8.OOE+00 2.801E+01
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-223
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
W-8 L4188-08 43 Sb-124 -5.20E+00 2.20E+00 8.90E+00 W-8 L4188-08 43 Sb-125 -2.30E+00 2.20E+00 7.60E+00 W-8 L4188-08 43 Se-75 l.OOE-01 1.20E+00 4.00E+00 W-8 L4188-08 43 Zn-65 3.10E+00 3.10E+00 l.OOE+01 W-8 L4188-08 43 Zr-95 5.00E-01 1.70E+00 5.70E+00 W-9 L4188-09 43 AcTh-228 1.02E+01 5.30E+00 1.70E+01 W-9 L4188-09 43 Ag-108m -1.28E+00 8.80E-01 3.20E+00 W-9 L4188-09 43 Ag-l lOm 4.OOE-0O 1.50E+00 5.20E+00 W-9 L4188-09 43 Ba-140 6.00E-01 2.90E+00 1.002+01 W-9 L4188-09 43 Be-7 O.OOE+00 9.00E+00 3.10E+01 W-9 L4188-09 43 Ce-141 -2.70E+00 1.602+00 5.40E+00 W-9 L4188-09 43 Ce- 144 2.OOE-0O 5.302+00 1.80E+01 W-9 L4188-09 43 Co-57 4.80E-0O 6.702-01 2.20E+00 W-9 L4188-09 43 Co-58 -1.00O+00 1.102+00 3.90E+00 W-9 L4188-09 43 Co-60 1.30E+00 1. O1E+00 3.602+00 W-9 L4188-09 43 Cr-51 -5.00E+00 1.10+01I 3.90E+01 W-9 L4188-09 43 Cs-134 -1.20E+00 1.202+00 4.30E+00 W-9 L4188-09 43 Cs- 137 5.00E-01 1.E10+00 3.702+00 W-9 L4188-09 43 Fe-59 2.OOE+00 2.60E+00 8.90E+00 W-9 L4188-09 43 H-3 2.70E+02 5.40E+02 1.602+03 W-9 L4188-09 43 1-131 -1.50E+00 3.302+00 1.20E+01 W-9 L4188-09 43 K-40 -4.00E+00 1.702+01 6.00E+01 W-9 L4188-09 43 La-140 7.00E-01 3.30E+00 1.20E+01 W-9 L4188-09 43 Mn-54 3.00E-01 1.20E+00 4.00E+00 W-9 L4188-09 43 Nb-95 -1.501E+00 1.30E+00 4.80E+00 W-9 L4188-09 43 Ru-103 -1.40E+00 1.20E+00 4.20E+00 W-9 L4188-09 43 Ru-106 -7.OOE+00 1.002+01 3.602+01 W-9 L4188-09 43 Sb-124 8.OOE-01 3.10E+00 I.IOE+01 W-9 LU188-09 43 Sb-125 1.80E+00 2.60E+00 8.802+00 W-9 L4188-09 43 Se-75 -1.50E+00 1.30E+00 4.502+00 W-9 L4188-09 43 Zn-65 7.90E+00 4.50E+00 1.50E+01 W-9 L4188-09 43 Zr-95 -7.OOE-01 1.80E+00 6.40E+00 w-l0 L4188-10 43 AcTh-228 6.OOE-01 3.50E+00 2.602+01 w-1o L4188-10 43 Ag-108m 6.60E-01 6.00E-01 2.00E+00 w-10 L4188-10 43 Ag-l lOm -1.22E+00 9.30E-01 3.30E+00 W-10 L4188-10 43 Ba-140 -1 .OOE-01 1.50E+00 5.20E+00 w-Io L4188-10 43 Be-7 -2.902+00 5.80E+00 2.00E+01 w-I0 UA188-10 43 Ce- 141 -6.102+00 2.00E+00 7.00E+00 w-10 L4188-10 43 Ce-144 2.50E+00 4.10E+00 1.40E+01 w-lo L4188-10 43 Co-57 1.30E-01 5.10E-01 1.70E+00
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-224
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
W-lO L4188-10 43 Co-58 -3.50E-01 7.70E-01 2.70E+O0 W-1O L4188-10 43 Co-60 9.40E-01 7.20E-01 2.40E+O0 W-1O L4188-10 43 Cr-51 -5.1OE+00 7.40E+00 2.50E+0O W-1O L4188-10 43 Cs-134 -8.OOE-01 7.OOE-01 2.50E+00 W.1O L4188-10 43 Cs-137 -7.00E-01 7.60E-01 2.70E+00 W-10 L4188-10 43 Fe-59 -9.OOE-01 1.60E+00 5.70E+00 W-10 L4188-10 43 H-3 1.80E+02 5.40E+02 1.60E+03 W-1o L4188-10 43 1-131 -1.50E+00 2.10E+00 7.10E+00 W.1o L4188-10 43 K-40 8.OOE+00 1.20E+01 4.1OE+01 W-1O L4188-10 43 La-140 -I.OOE-01 1.70E+00 6.OOE+00 W.1o L4188-10 43 Mn-54 -4.40E-01 6.90E-01 2.40E+00 W-10 L4188-10 43 Nb-95 3.20E-01 8.80E-01 3.OOE+00 W-1O L4188-10 43 Ru-103 -9.70E-01 7.70E-01 2.70E+00 W-10 L4188-10 43 Ru-106 -5.50E+00 6.70E+00 2.30E+0O w.10 L4188-10 43 Sb-124 -2.20E+00 1.80E+00 6.60E+00 W-10 L4188-10 43 Sb-125 4.OOE-01 1.70E+00 5.90E+00 W-10 L4188-10 43 Se-75 -9.60E-01 8.90E-01 3.IOE+00 W-10 L4188-10 43 Zn-65 7.20E+00 2.90E+00 9.60E+00 W-10 L4188-10 43 Zr-95 -I.OOE+00 1.20E+00 4.20E+00 W-11 L4188-11 43 AcTh-228 1.09E+01 4.10E+00 1.30E+0O W-1l L4188-11 43 Ag-108m -5.90E-01 8.20E-01 2.90E+00 W-1 [4188-11 43 Ag-ll0m 8.OOE-01 1.50E+00 5.OOE+00 W-1 I L4188-11 43 Ba-140 3.70E+00 2.30E+00 7.50E+00 W-1I [4188-11 43 Be-7 -1.50E+00 9.30E+00 3.20E+0I W-lI [4188-11 43 Ce-141 -9.OOE-01 1.40E+00 4.70E+00 W-l1 L4188-11 43 Ce-144 -7.OOE+00 6.50E+00 2.20E+01 W-lI L4188-11 43 Co-57 6.80E-01 8.20E-01 2.70E+00 W-lI L4188-11 43 Co-58 1.40E+00 I.IOE+00 3.60E+00 W-1I L4188-11 43 Co-60 -9.OOE-01 I.OOE+00 3.80E+00 W-ll L4188-11 43 Cr-51 -9.OOE+00 l.lOE+0 3.70E+OI W-lI L4188-11 43 Cs-134 9.OOE-01 l.lOE+00 3.60E+00 W-l1 L4188-11 43 Cs-137 8.OOE-01 l.OOE+O0 3.40E+00 W-lI1 L4188-11 43 Fe-59 3.90E+00 2.20E+00 7.20E+00 W-lI L4188-11 43 H-3 3.80E+02 5.40E+02 1.60E+03 W-l1 [4188-11 43 1-131 3.10E+00 3.10E+00 l.OOE+01 W-l1 [4188-11 43 K-40 -2.20E+01 1.60E+01 5.80E+01 W-lI L4188-11 43 La-140 4.30E+00 2.60E+00 8.60E+00 W-lI L4188-11 43 Mn-54 -9.OOE-01 I.IOE+00 4.OOE+00 W-1l L4188-11 43 Nb-95 -1.70E+00 1.30E+00 4.70E+00 W-l1 L4188-11 43 Ru-103 -5.OOE-01 1.20E+00 4.20E+00
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-225
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
W-Ii L4188-11 43 Ru-106 -8.20E+00 9.50E+00 3.40E+01 W-li L4188-11 43 Sb-124 -1.501+00 2.80E3+00 I .OOE3+0 W-l1 L4188-11 43 Sb-125 2.80E3+00 2.60E-,-00 8.70E+00 W-ll L4188-11 43 Se-75 9.OOE-01 1.30E1,-00 4.4013-00 W-l1 L4188-11 43 Zn-65 9.701E+00 3.70E3+00 I1.20E+01 W-11 L4188-11 43 Zr-95 2.50E+00 1.901E+00 6.50E3+00 W-12 L4188-12 43 AcTh-228 -1.90E3+00 4. 101+00 1.40E+01 W-12 L4188-12 43 Ag-108m 1.40E-01 8.20E3-01 2.80E+00 W-12 L4188-12 43 Ag-l lOIm 4.001E-01 I1.20E3+00 4.30Ei-00 W-12 L4188-12 43 Ba-140 0.OOE2+00 2.001E+00 7.20E3+00 W-12 L4188-12 43 Be-7 -2.OOE+00 8.50E3+00 2.90E3+01 W-12 L4188-12 43 Ce-141 1.20E+00 1.60E1i-00 5.20E3+00 W-12 L4188-12 43 Ce-144 -3.JOE-,00 5.201E+00 1.80E+01 W-12 LA188-12 43 Co-57 3.801E-01 6.60E-01 2.20E+00 W-12 L4188-12 43 Co-58 -6.00OE-01 9.70E3-01 3.50E3+00 W-12 L4188-12 43 Co-60 I1.771E+00 9.80E3-01 3.20E+00 W-12 L4188-12 43 Cr-51 I1.05E+01 9.90E3+00 3.30E-i01 W-12 L4188-12 43 Cs-134 2.06E3+00 9.60E-01 3.10OE+00 W-12 L4188-12 43 Cs-137 -2.601E+00 1.1OE3+00 3.901E+00 W-12 L4188-12 43 Fe-59 5.OOE-01 2.201E+00 7.70E+00 W-12 L4188-12 43 H-3 1.50E+02 5.40E+02 1.60E-t-03 W-12 L4188-12 43 1-131 2.70E+00 2.80E3+00 9.40E+00 W-12 LA188-12 43 K-40 -1 .401E+01 1.30E+01 4.60E3+01 W-12 LA188-12 43 La-140 0.OOE3+00 2.301E+00 8.30E+O0 W-12 L4188-12 43 Mn-54 -7.001E-02 9.70E3-01 3.40E3+00 W-12 L4188-12 43 Nb-95 -4.70E+00 1.401E+00 5.30E-i-00 W-12 L4188-12 43 Ru-103 -1.1OE-+00 1.OOE+00 3.60E+00 W-12 L4188-12 43 Ru-106 1.60E+00 9. 101+00 3.IOE+01 W-12 L4188-12 43 Sb-124 1.OE1+00 2.40E+00 8.50E+00 W-12 LA188-12 43 Sb-125 -1.50E3+00 2.40E3+00 8.50E3+00 W-12 LA188-12 43 Se-75 -2.001E-01 1.20E+00 4.20E1i-00 W-12 LA188-12 43 Zn-65 1.091E+01 3.90E3+00 I1.20E+01 W-12 L4188-12 43 Zr-95 -1.I 10+00 I1.601E+00 5.80E3+00 W-13 LA188-13 43 AcTh-228 -6.OOE-01 3.80E+00 1.301E+01 W-13 LA188-13 43 Ag-108m -5.IOE-01 5.40E-01 I1.90E+00 W-13 L4188-13 43 Ag-I lOm -1.37E+00 9.90E1-01 3.50E+00 W-13 L4188-13 43 Ba-140 3.OOE-01 1.50E+00 5.40E+00 W-13 L4188-13 43 Be-7 2.40E-,-00 6.20E+00 2.IO0E+01 W-13 L4188-13 43 Ce-141 1.801E+00 1.IOE3+00 3.601E+00 W-13 L4188-13 43 Ce-144 -L OOE-01 3.90E3+00 1.301E+01
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-226
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
W-13 LA188-13 43 Co-57 -6.90E-01 4.90E-01 1.70E+00 W-13 LA188-13 43 Co-58 -8.00E-01 6.90E-01 2.50E+00 W-13 LA188-13 43 Co-60 6.10E-01 7.402-01 2.50E+00 W-13 LA188-13 43 Cr-51 -3.40E+00 7.40E+00 2.50E+01 W-13 LA188-13 43 Cs-134 -4.10E-01 6.80E-01 2.40E+00 W-13 LA188-13 43 Cs-137 -4.40E-01 7.40E-01 2.60E+00 W-13 LA188-13 43 Fe-59 -6.00E-01 1.50E+00 5.40E+00 W-13 LA188-13 43 H-3 4.30E+02 5.40E+02 1.60E+03 W-13 LA188-13 43 1-131 -1.50E+00 2.20E+00 7.702+OO W-13 LA188-13 43 K-40 4.00E+00 1.20E+01 4.OOE+01 W-13 LA188-13 43 La-140 3.002-01 1.80E+00 6.20E+00 W-13 LA188-13 43 Mn-54 0.00+00 7.00E-01 2.40E+00 W-13 LA188-13 43 Nb-95 -6.90E-01 7.80E-01 2.80E+00 W-13 LA188-13 43 Ru-103 -1.83E+00 7.60E-01 2.80E+00 W-13 L4188-13 43 Ru-106 -3.302+00 6.60E+00 2.30E+01 W-13 LA188-13 43 Sb-124 1.60E+00 1.80E+00 6.102+00 W-13 LA188-13 43 Sb-125 7.00E-01 1.80E+00 5.902+00 W-13 LA188-13 43 Se-75 1.20E+00 8.80E-01 2.90E+00 W-13 LU188-13 43 Zn-65 -1.40E+00 1.90E+00 6.70E+00 W-13 LA188-13 43 Zr-95 -2.002-01 1.IOE+00 4.002+00 W-14 LA188-14 43 AcTh-228 4.10E+00 5.20E+00 1.80E+01 W-14 LA188-14 43 Ag-108m 4.80E-01 7.30E-01 2.50E+00 W-14 LA188-14 43 Ag-I lOm -8.00E-01 1.30E+00 4.50E+00 W-14 LA188-14 43 Ba-140 -2.002-01 2.30E+00 8.30E+00 W-14 LA188-14 43 Be-7 -2.40E+00 8.20E+00 2.80E+01 W-14 LA188-14 43 Ce-141 -4.40E+00 2.302+00 8.00E+00 W-14 LA188-14 43 Ce-144 -2.00E+00 4.60E+00 1.60E+01 W-14 LA188-14 43 Co-57. 1.40E-01 6.20E-01 2.10E+00 W-14 LU188-14 43 Co-58 3.90E-01 9.60E-01 3.30E+00 W-14 LU188-14 43 Co-60 3.002-01 1.IOE+00 3.702+00 W-14 U4188-14 43 Cr-51 2.20E+00 9.60E+00 3.20E+01 W-14 LA188-14 43 Cs-134 -6.00E-01 1.10E+00 3.902+00 W-14 14188-14 43 Cs-137 -4.30E-01 9.70E-01 3.40E+00 W-14 14188-14 43 Fe-59 4. 10E+00 2.20E+00 7.10E+00 W-14 UA188-14 43 H-3 1.IOE+02 5.302+02 1.60E+03 W-14 LA188-14 43 1-131 5.30E+00 2.90E+00 9.50E+00 W-14 L4188-14 43 K-40 -1.002+01 1.702+01 6.00E+01 W-14 L4188-14 43 La-140 -3.002-01 2.70E+00 9.60E+00 W-14 LA188-14 43 Mn-54 -5.00E-01 1.OOE+00 3.60E+00 W-14 L4188-14 43 Nb-95 -5.002-01 1.IOE+00 4.00E+00
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-227
Indiana Michigan Power Co., DC Cook Nuclear Plant kadiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
W-14 L4188-14 43 Ru-103 -1.OOE+00 *IOE+00 3.80E+O00 W-14 L4188-14 43 Ru-106 5.80E+00 9. 10E+00 3.101E+01 W-14 L4188-14 43 Sb-124 2.80E+00 2.40E3+00 8.20E+00 W-14 L4188-14 43 Sb-125 -5.001E-01 2.40E+00 8.40E+00 W-14 L4188-14 43 Se-75 I .OOE-01 I. lOE+00 3.80E+00 W-14 L4188-14 43 Zn-65 9.40E+00 3.60E.00 1.20E+01 W-14 L4188-14 43 Zr-95 I1.80E+O0 1.70E+00 5.80E+00
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-228
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
Ws SW'-'- L2993-01 AcTh-228 -4.001E-01 3.60E+00 1.20E+01 SW'-'- L2993-01 Ag-108m 8.601E-01 5.50E-01 I1.80E-i00 SW'-'- L2993-01 Ag-I lOm 5.OOE-02 9.40E-01 3.20E+00 SWL-l L2993-01 Ba-140 7.OOE-01 2.80E+00 9.70E+00 SWL-l L2993-01 Be-7 1.1 lE+01 6.80E+00 2.20E+01 SWL-l L2993-01 Ce-141 -7.OOE-01 1.50E+00 4.90E+00 SW'-'- L2993-01 Ce-144 -3.60E+00 3.70E+00 1.30E+01 SWL-I L2993-01 Co-57 I1.50E-01 4.80E-01 I1.60E+00 SWL-I L2993-01 Co-58 3.20E-01 7.10E-01 2.40E+00 SWL-I L2993-01 Co-60 -4.OOE-02 7.OOE-01 2.50E+00 SWL-I L2993-01 Cr-5I -1.93E+01 9.70E+00 3.40E+01 SWL-I L2993-01 Cs-134 5.OOE-02 6.60E-01 2.30E+00 SWL-I L2993-01 Cs-137 L OOE-02 6.70E-01 2.30E+00 SWL-1 L2993-01 Fe-59 -1I.90E+00 2.40E+00 8.60E+00 SWL-i L2993-01 1-131 -1I.90E+00 6.50E+00 2.20E+01 SWL-1 L2993-01 K-40 I1.301E+01 1.20E+01 3.90E+01 SWL-1 L2993-01 La-140 8.00OE-01 3.20E+00 1.lOE3+01 SWL-1 L2993-01 Mn-54 -6.50E-01 7.OOE-01 2.40E+00 SWL-1 L2993-01 Nb-95 -2.70E-i00 1.40E+O0 5.OOE+00 SWL-1 L2993-01 Ru-103 -8.OOE-01 9.1OE-01 3.20E+00 SWL-1 L2993-01 Ru-106 -6.20E+00 6.50E+00 2.30E+01 SWL-I L2993-01 Sb-124 -2. 10E+O0 1.90E-i-00 6.903+O00 SWL-I L2993-01 Sb-125 I1.60E+00 1.70E+00 5.801E+00 SWL-1 L2993-01 Se-75 7.50E-01 9.lOE-0l 3.001E+00 SWL-1 L2993-01 Zn-65 2.40E+00 1.30E+00 4.30E+00 SwL-I L2993-01 Zr-95 -l1.50E+00 I1.40E+00 4.80E+00 SWL-2 L2993-02 Aclh-228 I1.90E+00 3.30E+00 1.lOE+01 SWL-2 L2993-02 Ag-108m 5.90E-01 5.60E-01 1.90E+00 SWL-2 L2993-02 Ag-t lOm -6.70E-01 8.80E-01 3. 10E+00 SWL-2 L2993-02 Ba- 140 1.IOE1+00 2.80E+00 9.80E+00 SWL-2 L2993-02 Be-7 2.10OE+00 6.801E+00 2.30E+01 SWL-2 L2993-02 Ce-141 5.OOE-01 2.OOE+00 6.601E+00 SWL-2 L2993-02 Ce-144 -8.40E+00 3.90E+00 I1.30E+01 SWL-2 L2993-02 Co-57 -ILOOE-02 5.OOE-01 I1.70E+00 SWL-2 L2993-02 Co-58 2.60E-01 8.201E-01 2.80E+00 SWL-2 L2993-02 Co-60 9.00E-0l 6.90E-01 2.30E+00 SWL-2 L2993 -02 Cr-51 -7.90E+00 9.80E+00 3.40E+01 SWL-2 12993-02 Cs-134 -l.OIE+00 7.30E-01 2.60E+O0 SWL-2 L2993-02 Cs-137 - I. lE+O0 7.OOE-01 2.50E+O00
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-229
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
SWL-2 L2993-02 Fe-59 -4.OOE-0O 2.40E+OO 8.50E+00 SWL-2 L2993-02 1-131 -5.50E+00 6.50E+00 2.20E+01 SWL-2 L2993-02 K-40 1.80E+01 1.20E+0I 3.90E+0I SWL-2 L2993-02 La-140 1.30E+00 3.30E+00 I . IOE+OI SWL-2 L2993-02 Mn-54 1.80E-0O 6.90E-01 2.30E+00 SWL-2 L2993-02 Nb-95 -2.00E-01 1.20E+00 4.30E+00 SWL-2 L2993-02 Ru-103 -9.50E-01 9.20E-01 3.20E+00 SWL-2 L2993-02 Ru-106 -8.50E+O0 6.50E+00 2.30E+0I SWL-2 L2993-02 Sb- 124 -1.60E+00 1.90E+00 6.80E+00 SWL-2 L2993-02 Sb-125 I.1OE+00 1.70E+00 5.80E+O0 SWL-2 L2993-02 Se-75 3.OOE-02 9.20E-01 3. IOE+00 SWL-2 L2993-02 Zn-65 -4.OOE-01 2.30E+00 8.OOE+00 SWL-2 L2993-02 Zr-95 6.OOE-Oi 1.30E+00 4.40E+00 SWL-3 L2993-03 AcTh-228 4.40E+00 3.90E+00 1.30E+0I SWL-3 L2993-03 Ag-108m 1.29E+00 4.90E-0O 1.60E+OO SWL-3 L2993-03 Ag-I lOm -I.OOE-0O 8.60E-0O 3.OOE+O0 SWL-3 L2993-03 Ba-140 -3.90E+O0 2.40E+00 9.00E+O0 -
SWL-3 L2993-03 Be-7 -6.OOE+00 6.30E+00 2.20E+01 SWL-3 L2993-03 Ce-141 2.00E-01 I .80E+OO 6.20E+00 SWL-3 L2993-03 Ce-144 -3.00E-0I 3.30E+00 1.IOE+0I SWL-3 L2993-03 Co-57 -4.50E-01 6.60E-0O 2.20E+00 SWL-3 L2993-03 Co-58 -6.00E-0O 7.00E-01 2.50E+00 SWL-3 L2993-03 Co-60 6.90E-0O 6.20E-01 2.10E+O0 SWL-3 L2993-03 Cr-SI -1.03E+01 9.101E+00 3.10E+0I SWL-3 L2993-03 Cs-134 4.70E-0O 6.20E-01 2.1OE+00 SWL-3 L2993-03 Cs-137 2.80E-01 6.50E-0I 2.20E+00 SWL-3 L2993-03 Fe-59 2. 10OE+OO 2.20E3+00 7.50E+00 SWL-3 L2993-03 1-131 6.70E+00 5.90E+00 2.00E+0O SWL-3 L2993-03 K-40 -3.OOE+00 1.20E+0O 4.20E+01 SWL-3 L29Y3-03 La-140 -4.50E+00 2.80E+OO l.00E+01 SWL-3 L2993-03 Mn-54 O.OOE+00 5.30E-OI 1.80E+00 SWL-3 L2993-03 Nb-95 -5.30E-OI 9.30E-0O 3.20E+00 SWL-3 L2993-03 Ru-103 -1.33E+00 8.50E-0I 3.OOE+00 SWL-3 L2993-03 Ru-106 7.50E+OO 6.20E+00 2.10E+0l SWL-3 L2993-03 Sb-124 -3.80E+O0 1.80E+00 6.90E+00 SWL-3 L2993-03 Sb-125 3.OOE-0O 1.60E+0O 5.30E+00 SWL-3 L2993-03 Se-75 5.101E-0I 7.20E-OI 2.40E+00 SWL-3 L2993-03 Zn-65 -3.OOE+00 1.40E+00 5.00E+00 SWL-3 L2993-03 7Z-95 -4.OOE-0l 1.40E+00 4.70E+00
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-230
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg) sw1 L2175-01 05 AcTh-228 4.00E-01 2.50E+00 9.50E+00 SWL-1 L2175-01 05 Ag-108m -1.50E-01 3.20E-01 1.10E+00 SWLI-1 L2175-01 05 Ag-l1Orm 5.90E-0O 5.70E-01 1.90E+00 SWL-1 L2175-01 05 Ba-140 -4.10E+00 2.70E+00 9.60E+00 SWL-1 L2175-01 05 Be-7 6.40E+00 4.60E+00 1.50E+01 SWL-I L2175-01 05 Ce-141 5.00E-01 1.60E+00 5.30E+00 SWL-I L2175-01 05 Ce-144 -3.50E+00 2.10E+00 7.30E+00 SWL-I L2175-01 05 Co-57 4.20E-01 2.80E-01 9.20E-01 SWL-I L2175-01 05 Co-58 -2.40E-01 4.60E-01 1.60E+00 SWL-1 L2175-0i 05 Co-60 2.00E-02 4.10E-01 1.40E+00 SWL-1 L2175-01. 05 Cr-51 1.60E+00 7.30E+00 2.40E+01 SWL-I L2175-01 05 Cs-134 8.30E-0O 4.00E-01 1.30E+00 SWL-1 L2175-01 05 Cs-137 -2.50E-01 4.00E-01 1.40E+00 SWL-1 L2175-01 05 Fe-59 6.002-01 1.70E+00 5.60E+00 SWL-1 L2175-01 05 1-131 8.30E+00 9.10E+00 3.00E+01 SWL-1 L2175-01 05 K-40 -1.OOE+00 9.002+00 3.00E+01 SWL-1 L2175-01 05 La-140 -4.80E+00 3.10E+00 I.IOE+01 SWL-1 L2175-01 05 Mn-54 -3.20E-0O 3.60E-01 1.30E+00 SWL-1 L2175-01 05 Nb-95 2.90E-01 7.10E-01 2.40E+00 SWL-1 L2175-01 05 Ru-103 -2.17E+00 6.40E-01 2.30E+00 SWL-1 L2175-01 05 Ru-106 3.20E+00 3.80E+00 1.30E+01 SWL-1 L2175-01 05 Sb-124 l.OOE-01 1.302+00 4.30E+00 SWL-1 L2175-01 05 Sb-125 1.60E-01 9.70E-01 3.20E+00 SWL-I L2175-01 05 Se-75 3.20E-01 4.80E-01 1.60E+00 SWL-1 L2175-01 05 Zn-65 -1.50E+00 1.10O+00 3.90E+00 SWL-1 L2175-01 05 Zr-95 1.02E+00 9.10E-01 3.00E+00 SWL,2 L2175-02 05 AcTh-228 1.30E+00 2.30E+00 7.80E+00 SWL-2 L2175-02 05 Ag-108m -3.30E-01 3.40E-01 1.202+00 SWL-2 L2175-02 05 Ag-I lOm -4.70E-01 6.00E-01 2.102+00 SWL-2 L2175-02 05 Ba-140 -2.00E-01 3.60E+00 1.20E+01 SWL-2 L2175-02 05 Be-7 -7.00E-01 5.10E+00 1.70E+01 SWL-2 L2175-02 05 Ce-141 1.40E+00 1.70E+00 5.70E+00 SWL-2 L2175-02 05 Ce-144 2.30E+00 2.60E+00 8.50E+00 SWL-2 L2175-02 05 Co-57 -2.10E-01 3.30E-01 I.IOE+00 SWL-2 L2175-02 05 Co-58 -5.60E-01 5.702-01 2.00E+00 SWL-2 L2175-02 05 Co-60 4.00E-02 4.30E-01 1.50E+00 SWL-2 L2175-02 05 Cr-51 4.00E+00 8.50E+00 2.802+01 SWL-2 L2175-02 05 Cs-134 9.40E-01 4.80E-01 1.60E+00
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-231
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
SWL-2 L2175-02 05 Cs- 137 -5.50E-0l 4.40E-0O 1.50E+00 SWL-2 L2175-02 05 Fe-59 -8.OOE-0l 1.70E+00 5.90E+O0 SWL-2 L2175-02 05 1-131 -1 .OOE+00 1.20E+01 4.00E+01 SWL-2 L2175-02 05 K-40 6.80E+00 8.50E+00 2.80E+01 SWL-2 L2175-02 05 La- 140 -2.00E-01 4. IOE+00 1.40E+01 SWL-2 L2175-02 05 Mn-54 -9.90E-01 4.50E-0O 1.60E+00 SWL-2 L2175-02 05 Nb-95 3.00E-0O 1.20E+00 4.00E+00 SWL-2 L2175-02 05 Ru-103 -1.94E+00 7.20E-0O 2.50E+00 SWL-2 L2175-02 05 Ru-106 1.50E+00 4.10E+00 1.40E+01 SWL-2 L2175-02 05 Sb-124 -1.30E+O0 1.50E+00 5.10E+00 SWL-2 L2175-02 05 Sb-125 -8.00E-01 l .lOE+00 6.00E+00 SWL-2 L2175-02 05 Se-75 -2.30E-O1 6.20E-0O 2.10E+00 SWL-2 L2175-02 05 Zn-65 -8.OOE-01 1.50E+00 5.00E+00 SWL-2 L2175-02 05 Zr-95 2.00E-0O 9.40E-0O 3.20E+00 SWL-3 L2175-03 05 Acll-228 -1.80E+00 2.90E+00 9.80E+00 SWL-3 L21 75-03 05 Ag-108m -4.00E-0O 3. 1OE-01 1. O10+00 SWL-3 L2175-03 05 Ag- lOnm -1.15E+00 5.70E-01 2.00E+00 SWL-3 L2175-03 05 Ba-140 1.40E+00 3. 10E+00 1.10E+01 SWL-3 L2175-03 05 Be-7 -2.50E+00 4.60E+00 1.60E+01 SWL-3 L2175-03 05 Ce-141 -2.00E-01 1.60E+00 5.202+00 SWL-3 L2 175-03 05 Ce-144 0.OOE+00 2.20E+00 7.40E+00 SWL-3 L2175-03 05 Co-57 8.00E-02 2.80E-01 9.30E-01 SWL-3 L2175-03 05 Co-58 -9.OOE-02 4.80E-01 1.60E+00 SWL-3 L2175-03 05 Co-60 -4.90E-01 4.20E-0O 1.50E+00 SWL-3 L2175-03 05 Cr-51 1.13E+0O 7.70E+00 2.502+01 SWL-3 L2175-03 05 Cs-134 5.90E-0O 4.00E-01 1.302+00 SWL-3 L2175-03 05 Cs-137 -8.90E-0O 4.20E-01 1.50E+00 -
SWL-3 L2175-03 05 Fe-59 -1.40E+00 1.70E3+00 5.802+00 SWL-3 L2175-03 05 1-131 1.902+01 l.10+01 3.502+01 SWL-3 L2175-03 05 K-40 1.25E+01 9.IOE+00 3.002+01 SWL-3 L2175-03 05 La- 140 1.60E+00 3.60E+00 1.202+01 SWL-3 L2175-03 05 Mn-54 -1.80E-0O 3.80E-01 1.302+00 SWL-3 L2175-03 05 Nb-95 3.00E-01 1.70E+00 5.60E+00 SWL-3 L2175-03 05 Ru-103 -2.37E+00 6.70E-0O 2.40E+00 SWL-3 L2175-03 05 Ru- 106 -1.OOE+00 4.00E+00 1.30E+01 SWL-3 L2175-03 05 Sb- 124 -3.00E-01 1.30E+00 4.50E+00 SWL-3 L2175-03 05 Sb- 125 -1.88E+00 9.80E-0O 5.80E+00 SWL-3 L2175-03 05 Se-75 -3.50E-0I 4.902-01 1.702+00 SWL-3 L21 75-03 05 Zn-65 -8.00E-0O 1.20E3+00 4.002+00 SWL-3 L2175-03 05 Zr-95 1.78E+00 9.50E-01 3.102+00
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-232
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
SWL-1 L2314-01 09 AcTh-228 O.OOE+00 3.50E+00 1.20E+0O SWL-I L2314-01 09 Ag-108m 1.80E-0I 4.60E-01 1.60E+00 SWL-1 L2314-01 09 Ag-l lOm 1.05E+00 7.90E-01 2.70E+00 SWL-1 L2314-01 09 Ba-140 -3.10E+00 2.40E+00 8.60E+00 SWL-1 L2314-01 09 Be-7 6.10E+00 5.70E+00 I.90E+01 SWL-I L2314-01 09 Ce-141 1.50E+00 1.20E+00 3.90E+00 SWL-1 L2314-01 09 Ce-144 -3.OOE+00 3.1OE+00 1.OOE+0I SWL-1 L2314-01 09 Co-57 1.70E-01 4.OOE-01 1.30E+00 SWL-1 L2314-01 09 Co-58 -1.OOE-01 6.40E-01 2.20E+00 SWL-I L2314-01 09 Co-60 -1.80E-01 6.30E-01 2.20E+0O SWL-1 L2314-01 09 Cr-51 2.10E+00 8.OOE+00 2.70E+01 SWL-I L2314-01 09 Cs-134 -3.20E-01 5.70E-01 2.00E+OO SWL-I L2314-01 09 Cs-137 -1.18E+00 5.70E-01 2.OOE+OO SWL-I L2314-01 09 Fe-59 1.90E+00 2.20E+00 7.30E+OO SWL-I L2314-Oi 09 1-131 8.1OE+00 S.SOE+00 1.80E+01 SWL-I L2314-01 09 K-40 2.OOE+00 I.lOE+0I 3.80E+0O SWL-I L2314-01 09 La-140 -3.60E+00 2.70E+00 9.90E+0O SWL-1 L2314-01 09 Mn-54 -3.50E-0O 5.10E-01 1.80E+OO SWL-I L2314-01 09 Nb-95 7.50E-0O 8.80E-01 2.90E+OO SWL-I L2314-01 09 Ru-103 -2.30E-01 8.10E-01 2.80E+00 SWL-I L2314-01 09 Ru-106 3.90E+00 5.50E+00 1.80E+01 SWL-I L2314-01 09 Sb-124 3.00E-0O 1.80E+00 6.1OE+O0 SWL-1 L2314-01 09 Sb-125 8.OOE-01 1.50E+00 4.70E+O0 SWL-1 L2314-01 09 Se-75 -3.30E-0I 6.70E-01 2.30E+00 SWL-1 L2314-01 09 Zn-65 1.20E+O0 1.70E+00 5.60E+00 SWL-1 L2314-01 09 Zr-95 1.30E+00 1.20E+00 3.90E+00 SWL-3 L2314-03 09 AcTh-228 3.20E+00 3.30E+00 1.1OE+01 SWL-3 L2314-03 09 Ag-108m -1.30E-01 5.40E-01 1.90E+00 SWL-3 L2314-03 09 Ag-l lOm l.OOE-01 l.OOE+00 3.40E+00 SWL-3 L2314-03 09 Ba-140 -1.90E+00 3.40E+00 1.20E+0O SWL-3 L2314-03 09 Be-7 4.80E+00 7.10E+00 2.40E+01 SWL-3 L2314-03 09 Ce-141 -4.60E+00 2.20E+00 7.60E+00 SWL-3 L2314-03 09 Ce-144 -1.50E+00 3.50E+00 1.20E+0I SWL-3 L2314-03 09 Co-57 2.70E-0O 4.40E-01 1.50E+00 SWL-3 L2314-03 09 Co-58 -1.92E+00 8.IOE-01 3.OOE+00 SWL-3 L2314-03 09 Co-60 2.60E-01 8.80E-01 3.OOE+O0 SWL-3 L2314-03 09 Cr-51 2.50E+00 9.80E+00 3.30E+01 SWL-3 L2314-03 09 Cs-134 -1.44E+00 8.80E-01 3.10E+0O
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-233
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
SWL-3 L2314-03 09 Cs-137 1.40E+00 7.20E-01 2.40E+00 SWL-3 L2314-03 09 Fe-59 5.00E-01 3.00E+00 1.00+01 SWL-3 L2314-03 09 1-131 -5.40E+00 7.10E+00 2.40E+01 SWL-3 L2314-03 09 K-40 0.OOE+00 1.40E+01 4.70E+01 SWL-3 L2314-03 09 La- 140 -2.20E+0O 3.90E+00 1.402+01 SWL-3 L2314-03 09 Mn-54 5.70E-01 7.20E-01 2.40E+00 SWL-3 L2314-03 09 Nb-95 -2.00E+00 1.102+00 3.90E+00 SWL-3 L2314-03 09 Ru-103 -1.40E+00 1.30E+00 4.70E+00 SWL-3 L2314-03 09 Ru-106 8.00E+00 6.60E+00 2.20E+01 SWL-3 L2314-03 09 Sb-124 -8.00E-01 2.30E+00 8.10E+00 SWL-3 L2314-03 09 Sb-125 1.30E+00 1.80E+00 5.90E+00 SWL-3 L2314-03 09 Se-75 5.40E-01 8.90E-01 3.002+00 SWL-3 L2314-03 09 Zn-65 -1.10O+00 1.60E+00 5.80E+00 SWL-3 L2314-03 09 Zr-95 5.00E-01 1.40E+00 4.90E+00 SWL-I L2516-01 11 AcTh-228 9.90E+00 4.20E+00 1.30E+01 SWL-I L2516-01 11 Ag-108m 1.23E+00 9.30E-01 3.10E+00 SWL-I L2516-01 11 Ag-l lOm -1.00-01 l.50O+00 5.50E+00 SWL-I L2516-01 11 Ba- 140 -1.90E+00 3.00E+00 1.102+01 SWL-I L2516-01 11 Be-7 -3.00+00 l.lOE+01 3.70E+01 SWL'- L2516-01 11 Ce-141 -2.20E+00 2. 1OE+00 7.40E+00 SWL,- L2516-01 11 Ce-144 -2.OOE-01 6.10E+00 2.10E+01 SWI-. L2516-01 11 Co-57 3.30E-01 7.60E-01 2.60E+00 SWL-' L2516-01 11 Co-58 -1.80E+00 1.20E+00 4.50E+00 SWL-- L2516-01 11 Co-60 -5.00E-01 1.20E+00 4.30E+00 SWL-I L2516-01 11 Cr-51 -1.10O+01 1.40E+01 4.80E+01 -
SWL-I L2516-01 11 Cs-134 1.80E+00 1.I0E+00 3.50E+00 SWL-I L2516-01 11 Cs-137 -1.20E+00 1.10+00 4.20E+00 SWL-I L2516-01 11 Fe-59 1.50E+00 3.90E+00 1.402+01 SWL-I L2516-01 11 H-3 7.OOE+02 3.80E+02 1.E10+03 SWL-I L2516-01 11 1-131 1.70E+00 5.50E+00 1.90E+01 SWL-I L2516-01 11 K-40 3.40E+01 1.90E+01 6.30E+01 SWL-I L2516-01 11 La- 140 -2.10E+00 3.40E+00 1.30E+01 SWL-I L2516-01 11 Mn-54 -3.OOE-01 1.002+00 3.80E+00 SWL-I L2516-01 11 Nb-95 -2.60E+00 1.50E+00 5.60E+00 SWL-I L2516-01 11 Ru-103 -1.OOE+00 1.40E+00 4.90E+00 SWL--I L2516-01 11 Ru-106 2.40E+01 1.10E+01 3.60E+01 SWL- I L2516-01 11 Sb-124 -2.1 OE+00 3.OOE+00 1.20E+01 SWL-I L2516-01 11 Sb-125 2.80E+00 3.00E+00 1.00E+01
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-234
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
SWL-I L2516-01 11 Se-75 -2.20E+00 1.20E+00 4.40E+00 SWL-I L2516-01 11 Zn-65 1.36E+01 4.80E+00 l.50E+01 SWL-I L2516-01 11 Zr-95 -2.80E+00 2.30E+00 8.60E+00 SWL-2 L2516-02 11 AcTh-228 7.10E+00 3.OOE+00 9.40E+00 SWL-2 L2516-02 11 Ag-108m 8.OOE-01 6.40E-01 2.10E+00 SWL-2 L2516-02 11 Ag-lOim -1.OOE+00 1.20E+00 4.20E+00 SWL-2 L2516-02 11 Ba-140 4.90E+00 2.80E+00 9.30E+00 SWL-2 L2516-02 11 Be-7 -1.29E+01 7.90E+00 2.80E+01 SWL-2 L2516-02 11 Ce-141 -3.20E+00 2.70E+00 9.20E+O0 SWL-2 L2516-02 11 Ce-144 3.OOE-01 4.60E+00 1.60E+0O SWL-2 L2516-02 11 Co-57 -L.OOE-0I 5.90E-01 2.OOE+00 SWL-2 L2516-02 11 Co-58 -1.31E+00 9.OOE-01 3.30E+00 SWL-2 L2516-02 11 Co-60 1.22E+00 8.OOE-01 2.70E+00 SWL-2 L2516-02 11 Cr-51 -9.OOE+00 l.lOE+OI 3.90E+O1 SWL-2 L2516-02 11 Cs-134 1.17E+00 7.80E-01 2.60E+00 SWL-2 L2516-02 11 Cs-137 -1.13E+00 8.80E-01 3.10E+00 SWL-2 L2516-02 11 Fe-59 -4.20E+00 2.90E+00 1.1OE+O1 SWL-2 L2516-02 11 H-3 6.OOE+01 3.60E+02 1. IOE+03 SWL-2 L2516-02 11 1-131 -4.70E+00 6.OOE+00 2.10E+01 SWL-2 L2516-02 11 K-40 1.60E+01 1.40E+01 4.60E+0O SWL-2 L2516-02 11 La-140 5.60E+00 3.30E+00 1.IOE+01 SWL-2 L2516-02 11 Mn-54 2.70E-01 8.20E-01 2.80E+00 SWL-2 L2516-02 11 Nb-95 -I.OOE-O1 1.20E+00 4.IOE+00 SWL-2 L2516-02 11 Ru-103 -2.I1OE+00 I.IOE+00 4.OOE+00 SWL-2 L2516-02 11 Ru-106 9.70E+00 7.50E+00 2.50E+0O SWL-2 L2516-02 11 Sb-124 -1.90E+00 2.40E+00 8.70E+00 SWL-2 L2516-02 11 Sb-125 2.30E+00 2.OOE+00 6.80E+00 SWL-2 L2516-02 11 Se-75 1.40E+00 l.10E+00 3.60E+00 SWL-2 L2516-02 11 Zn-65 3.OOE-01 2.40E+00 8.30E+00 SWL-2 L2516-02 11 Zr-95 1.20E+00 1.60E+00 5.40E+00 SWL-3 L2516-03 11 AcTh-228 5.60E+00 4.60E+00 1.50E+0O SWL-3 L2516-03 11 Ag-108m -4.1OE-01 7.60E-01 2.70E+00 SWL-3 L2516-03 11 Ag-lOrm i.OOE-01 1.30E+00 4.70E+00 SWL-3 L2516-03 11 Ba-140 -1.40E+00 3.OOE+O0 I.IOE+0O SWL-3 L2516-03 11 Be-7 -2.22E+01 9.OOEi00 3.30E+0O SWL-3 L2516-03 11 Ce-141 -1.50E+00 1.90E+00 6.70E+00 SWL-3 L2516-03 11 Ce-144 -4.OOE+00 5.40E+00 1.80E+01 SWL-3 L2516-03 11 Co-57 8.OOE-01 7.10E-01 2.40E+00 SWL-3 L2516-03 11 Co-58 -2.40E+00 I.OOE+00 3.90E+00 SWL-3 L2516-03 11 Co-60 -8.60E-01 9.40E-01 3.50E+00
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-235
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
SWL-3 L2516-03 Cr-51 -1.20E+01 1.20E+01 4.30E+01 SWL-3 L2516-03 Cs-134 8.00E-01 l.OOE+00 3.40E+00 SWL-3 L2516-03 Cs-137 1.20E-0l 9.00E-0O 3.10E+00 SWL-3 L2516-03 Fe-59 1.90E+00 3.OOE+00 l.OOE+01 SWL-3 L2516-03 H-3 3.60E+02 3.70E+02 l. lOE+03 SWL-3 L2516-03 1-131 1.60E+00 6.60E+00 2.20E+OI SWL-3 L2516-03 K-40 3.20E+01 1.50E+01 4.90E+01 SWL-3 L2516-03 La-140 -1.60E+00 3.40E+00 1.30E+01 SWL-3 L2516-03 Mn-54 2.1 1E+00 9.70E-0O 3. 1OE+00 11 SWL-3 L2516-03 11 Nb-95 7.00E-01 1.50E+00 5.00E+00 SWL-3 L2516-03 11 Ru- 103 -1.20E+00 1.20E+00 4.40E+00 SWL-3 L2516-03 11 Ru-106 9.80E+00 9.10E+00 3.1OE+0O SWL-3 L2516-03 11 Sb-124 -1.60E+00 3.00E+00 1.10E+01 SWL-3 L2516-03 11 Sb-125 -6.OOE-0O 2.40E+00 8.20E+00 SWL-3 L2516-03 11 Se-75 1.30E+00 1.20E+OO 4.10E+00 SWL-3 L2516-03 11 Zn-65 -4.70E+00 2.1OE+00 7.90E+00 SWL-3 L2516-03 11 Zr-95 3.60E+00 1.80E+00 5.70E+00 -
16 16 SWL-I L2765-01 11 AcTh-228 3. 1OE+00 3.40E+00 1.30E+01 SWL-I L2765-01 11 Ag-108m 6.60E-01 6.80E-01 2.30E+00 16 SWL-1 L2765-01 16 Ag-l lOm 3.00E-01 l .10+00 3.90E+00 16 SWL-I L2765-01 11 Ba-140 l.OOE+00 3.30E+00 1.20E+01 16 SWL-I L2765-01 11 Be-7 I .90E+00 7.90E+00 2.70E+01 16 SWL-I L2765-01 11 Ce-141 8.00E-01 1.80E+00 6.00E+00 161 SWL-I L2765-01 11 Ce-144 1.20E+00 4.70E+00 1.60E+01 16 SWL-I L2765-01 Co-57 2.20E-01 6.10E-01 2.OOE+00 SWL-I L2765-01 16 Co-58 1.03E+00 9.20E-01 3.10E+00 SWL-I L2765-01 16 16 Co-60 6.80E-0O 8.70E-01 3.OOE+00 SWL-' L2765-01 16 Cr-51 -1.OOE+00 1.20E+0O 4.00E+01 SWL-I L2765-01 16 16 Cs-134 8.10E-OI 7.70E-01 2.60E+00 SWL-I L2765-01 16 Cs-137 -4.10-01 8.OOE-01 2.80E+00 SWL- I L2765-01 Fe-59 -6.20E+00 3. 10E+00 1.20E+01 SWL-1 L2765-01 1-131 -8.OOE-01 7.90E+00 2.70E+01 SWL-l L2765-01 K-40 1.10E+01 1.50E+01 5.OOE+01 SWL-I L2765-01 La-140 1.20E+00 3.80E+00 1.30E+01 SWL-I L2765-01 Mn-54 6.00E-01 8.60E-0O 2.90E+00 SWL-I L2765-01 Nb-95 -2.40E+00 1.60E+00 5.60E+00 SWL-I L2765-01 Ru-103 -1.80E+00 1.20E+00 4.20E+00 SWL-I L2765-01 Ru-106 -2.50E+00 7.80E+00 2.70E+01
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-236
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
SWL-I L2765-01 16 Sb-124 -1.20E+00 2.40E+00 8.90E+00 SWL-I L2765-01 16 Sb-125 4.OOE-0O 2.20E+00 7.40E3+00 SWL-' L2765-01 16 Se-75 1.90E+00 1.1OE+00 3.60E+00 SWL'- L2765-01 16 Zn-65 -1.20E+00 1.80E+00 6.40E+00 SWL-' L2765-01 16 Zr-95 -1.30E+00 1.60E+00 5.80E+00 SWL-2 L2765-02 16 AcTh-228 -4.70E+00 3.40E+00 1.20E+01 SWL-2 L2765-02 16 Ag-108m -9.80E-0O 5.80E-0O 2. 10E+00 SWL-2 L2765-02 16 Ag-I lrOm -4.00E-01 1.OOE+00 3.50E+00 SWL-2 L2765-02 16 Ba-140 7. 1OE+00 3.50E+00 1.1OE+0O SWL-2 L2765-02 16 Be-7 6.90E+00 8.OOE+00 2.70E+0O SWL-2 L2765-02 16 Ce-141 -1.OOE+00 1.60E+00 5.40E+00 SWL-2 L2765-02 16 Ce-144 1.50E+00 4.10E+00 1.40E+01 SWL-2 L2765-02 16 Co-57 4.OOE-02 5.30E-0O 1.80E+00 SWL-2 L2765-02 16 Co-58 -5.30E-0O 7.70E-0O 2.70E+00 SWL-2 L2765-02 16 Co-60 6.70E-0O 7.40E-0O 2.50E+00 SWL-2 L2765-02 16 Cr-51 3.50E+01 1.70E+01 5.30E+01 SWL-2 L2765-02 16 Cs-134 1.1 E+00 7.10E-0O 2.40E+00 SWL-2 L2765-02 16 Cs-137 -I.OOE-0O 7.50E-0I 2.60E+00 SWL-2 L2765-02 16 Fe-59 -1.30E+00 2.70E+00 9.80E+00 SWL-2 L2765-02 16 1-131 -9.30E+00 8.50E+00 3.OOE+0I SWL-2 L2765-02 16 K-40 1.90E+0O 1.30E+01 4.30E+01 SWL-2 L2765-02 16 La-140 8.20E+00 4.OOE+00 1.30E+0O SWL^2 L2765-02 16 Mn-54 O.OOE+00 7.90E-0O 2.70E+00 SWL-2 L2765-02 16 Nb-95 -3.OOE-01 1.lOE+00 3.90E+00 SWL-2 L2765-02 16 Ru-103 -1.IOE+00 1.lOE+00 3.70E+00 SWL-2 L2765-02 16 Ru-106 9.90E+00 6.90E+00 2.30E+0O SWL-2 L2765-02 16 Sb-124 -1.60E+00 2.20E+00 8.OOE+00 SWL-2 L2765-02 16 Sb-125 -1.40E+00 1.90E+00 6.70E+00 SWL-2 L2765-02 16 Se-75 -3.80E-0O 9.90E-0O 3.40E+00 SWL-2 L2765-02 16 Zn-65 -1.OOE+00 1.50E+00 5.40E+00 SWL-2 L2765-02 16 Zr-95 -1.20E+00 1.50E+00 5.20E+00 SWL-3 L2765-03 16 AcTh-228 6.30E+00 2.80E+00 8.90E+00 SWL-3 L2765-03 16 Ag-108m -2.30E-0O 6.40E-01 2.20E+00 SWL-3 L2765-03 16 Ag-I lOm -4.00E-0O l.lOE+00 4.OOE+00 SWL-3 L2765-03 16 Ba-140 5.30E+00 3.40E+00 l.lOE+0O SWL-3 L2765-03 16 Be-7 -1.70E+00 7.80E+00 2.70E+01 SWL-3 L2765-03 16 Cc-141 6.00E-01 1.60E+00 5.50E+00 SWL-3 L2765-03 16 Ce- 144 -4.50E+00 4.20E+00 1.50E+01 SWL-3 L2765-03 16 Co-57 4.50E-01 7.30E-0O 2.40E+00 SWL-3 L2765-03 16 Co-58 -1.86E+00 8.50E-0I 3.20E+00
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-237
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) . (pCi/kg)
SWL-3 L2765-03 16 Co-60 -9.30E-01 7.90E-01 2.90E+00 SWL-3 L2765-03 16 Cr-SI -5.OOE+00 1.20E+01 3.90E+01 SWL-3 L2765-03 16 Cs-134 -1.OOE-02 7.90E-01 2.80E+00 SWL-3 L2765-03 16 Cs-137 -4.20E-01 8.20E-01 2.90E+00 SWL-3 L2765-03 16 Fe-59 -1.50E+00 2.90E+00 l.OOE+01 SWL-3 L2765-03 16 1-131 4.90E+00 9.OOE+00 3.00E+01 SWL-3 L2765-03 16 K-40 -I.OOE+00 1.50E+01 5.10E+01 SWL-3 L2765-03 16 La- 140 6.10E+00 3.90E+00 1.30E+01 SWL-3 L2765-03 16 Mn-54 1.12E+00 6.80E-01 2.20E+00 SWL-3 L2765-03 16 Nb-95 7.OOE-0O 1.30E+00 4.30E+00 SWL-3 L2765-03 16 Ru-103 -3.OOE-0l 1.lOE+00 3.80E+00 SWL-3 L2765-03 16 Ru-106 I .40E+00 7.30E+00 2.50E+01 SWL-3 L2765-03 16 Sb-124 -1.20E+00 2.20E+00 8.10E+00 SWL3 L2765-03 16 Sb-125 -1.20E+00 1.90E+OO 6.70E+00 SWL-3 L2765-03 16 Se-75 7.90E-01 9.10E-01 3.00E+00 SWL-3 L2765-03 16 Z~n-65 6.OOE-0O 2.30E+00 7.90E+00 SWL-3 L2765-03 16 Zr-95 -3.20E+00 1.60E+00 6.OOE+00 SWrll W3233-04 20 H-3 -1.37E+03 4.OOE+02 1.30E+03 SWLr2 W3233-05 20 H-3 -1.70E+02 4.20E+02 1.30E+03 SWL-3 12233-06 20 H-3 -5.20E+02 4.IOE+02 1.30E+03 SWL-I L3458-01 29 Acib-228 5.20E+00 3.10E+00 2.20E+01 SWL-I L3458-01 29 Ag-108m 3.80E-01 6.80E-01 2.30E+00 SWL-I W3458-01 29 Ag- lOnm -I.OOE-01 1.OOE+00 3.70E+00 SWL-l W3458-01 29 Ba-140 -2.40E+00 2.50E+00 9.60E+00 SWL-I W3458-01 29 Be-7 -2.60E+00 7.70E+00 2.70E+01 SWL-' W3458-01 29 Cc-141 -2.30E+00 2.70E+00 9.10E+00 SW'-r W3458-01 29 Ce-144 2.10E+00 4.60E+00 1.60E+01 SW--' W3458-01 29 Co-57 8.80E-01 7.60E-01 2.50E+00 SWL-' W3458-01 29 Co-58 l .OOE-02 9. 1OE-01 3.20E+00 SWL-I W3458-01 29 Co-60 2.80E-01 8.70E-01 3.10E+00 SWL-I L3458-01 29 Cr-51 1.40E+01 1.1OE+01 3.70E+01 SWL-' W3458-01 29 Cs-134 2.10E-01 8.60E-0I 3.00E+00 SWL-I W3458-01 29 Cs-137 3.60E-01 8.70E-01 3.00E+00 SWL-I W3458-01 29 Fe-59 -4.00E-01 2.90E+00 l.OOE+01 SWL-1 W3458-01 29 1-131 -1.70E+00 5.90E+00 2.00E+01 SWL-I W3458-01 29 K-40 2.40E+01 1.50E+01 5.00E+01 SWLr- W3458-01 29 La-140 -2.70E+00 2.90E+00 l. OE+01
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-238
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
SWL-I L3458-01 29 Mn-54 -4.SOE-01 8.OOE-01 2.90E+00 SWL-I L3458-01 29 Nb-95 -9.OOE-01 1.20E+00 4. 1OE+00 SWL- L3458-01 29 Ru-103 -2.60E+O0 1.1OE+00 4.1OE+00 SWL-I L3458-01 29 Ru-106 -1.07E+01 7.90E1+00 2.90E+0O SWL-I L3458-01 29 Sb-124 -3.60E+00 2.50E+00 9.60E+00 SWLA L3458-01 29 Sb-125 -1.30E+00 2.00E+00 7.10E+O0 SWL- L3458-01 29 Se-75 -4.70E-01 9.50E-01 3.30E+00 SWL-- L3458-01 29 Zn-65 1.80E+00 2.60E+00 8.60E+00 SWL-I L3458-01 29 Zr-95 -I.OOE+O0 1.60E+00 5.90E+00 SWL-2 L3458-02 29 AcTh-228 4.50E+00 3.90E+00 1.30E+0O SWL-2 L3458-02 29 Ag-108m -1.07E+O0 5.80E-01 2.10E+O0 SWL-2 L3458-02 29 Ag-I Orm 6.OOE-02 9.90E-01 3.40E+O0 SWL-2 L3458-02 29 Ba-140 1.20E+00 2.30E+00 8.OOE+00 SWL-2 L3458-02 29 Be-7 -5.10E+00 6.70E+00 2.30E+O1 SWL-2 L3458-02 29 Ce-141 -3.10E+00 2.20E+00 7.40E+O0 SWL-2 L3458-02 29 Ce-144 8.OOE-01 3.90E+00 1.30E+OI SWL-2 L3458-02 29 Co-57 I.OOE-02 5. 1OE-01 1.70E+O0 SWL-2 L3458-02 29 Co-58 -4.40E-01 7.50E-01 2.60E+O0 SWL-2 L3458-02 29 Co-60 2.40E-01 7.50E-01 2.60E+O0 SWL-2 L3458-02 29 Cr-51 -I.10E+00 9.20E+00 3.10E+01 SWL-2 L3458-02 29 Cs-134 6.80E-01 6.90E-01 2.30E+00 SWL-2 L3458-02 29 Cs-137 -1.37E+00 7.50E-01 2.70E+00 SWL-2 L3458-02 29 Fe-59 -I.IOE+00 2.50E+00 8.70E+00 SWL-2 L3458-02 29 1-131 2.80E+00 4.40E+00 1.50E+0O SWL-2 L3458-02 29 K-40 -l.OOE+00 1.30E+01 4.30E+01 SWL-2 L3458-02 29 La-140 1.40E+00 2.70E+00 9.20E+00 SWL-2 L3458-02 29 Mn-54 -1.70E-01 6.80E-01 2.40E+00 SWL-2 L3458-02 29 Nb-95 5.50E-01 9.80E-01 3.30E+00 SWL-2 L3458-02 29 Ru-103 -2.23E+00 9.10E-01 3.30E+00 SWL-2 L3458-02 29 Ru-106 9.00E-01 6.60E+00 2.30E+0I SWL-2 L3458-02 29 Sb-124 -S.OOE-0I I.90E+00 6.70E+00 SWL-2 L3458-02 29 Sb-125 0.OOE+00 1.70E+00 6.00E+00 SWL-2 L3458-02 29 Se-75 I.OOE-01 9.30E-01 3.10E+00 SWL-2 L3458-02 29 Zn-65 -8.OOE-01 1.50E+00 5.40E+O0 SWL-2 L3458-02 29 Zr-95 2.60E+00 1.30E+00 4.30E+00 SWL-3 L3458-03 29 AcTh-228 -4.20E+00 2.20E+00 8.20E+00 SWL-3 L3458-03 29 Ag-108m -7.60E-01 5.40E-01 l.90E+00 SWL-3 L3458-03 29 Ag-I 1lm -1.80E-01 9.30E-01 3.20E+00 SWL-3 L3458-03 29 Ba-140 O.OOE+00 2.20E+00 7.60E+O0 SWL-3 L3458-03 29 Be-7 4.90E+00 6.70E+00 2.30E+0I
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-239
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCilkg) (pCi/kg)
SWL-3 L3458-03 29 Ce-141 -4.OOE-01 1.60E+00 5.40E+00 SWL-3 L3458-03 29 Ce-144 2.90E+00 3.90E+00 1.30E+01 SWL-3 L3458-03 29 Co-57 2.50E-01 5.102-01 1.702+00 SWL-3 L3458-03 29 Co-58 -1.14E+00 7.80E-01 2.80E+00 SWL-3 L3458-03 29 Co-60 -6.50E-01 6.80E-01 2.502+00 SWL-3 L3458-03 29 Cr-51 1.46E+0l 8.50E+00 2.80E+01 SWL-3 L3458-03 29 Cs-134 2.70E-01 7.60E-01 2.60E+00 SWL-3 L3458-03 29 Cs- 137 8.OOE-02 6.70E-01 2.30E+00 SWL-3 L3458-03 29 Fe-59 4.00E-01 2. 10E+00 7.50E+00 SWL-3 L3458-03 29 1-131 4.10E+00 4.202+00 1.40E+01 SWL-3 L3458-03 29 K-40 -I1 1OE+01 1.10E+01 3.902+01 SWL-3 L3458-03 29 LA-140 O.OOE+00 2.50E+00 8.70E+00 SWL-3 L3458-03 29 Mn-54 -4.90E-01 6.70E-01 2.40E+00 SWL-3 L3458-03 29 Nb-95 -3.70E+00 1.40E+00 5.30E+00 SWL-3 L3458-03 29 Ru-103 1.802-01 8.30E-01 2.80E+00 SWL-3 L3458-03 29 Ru-106 -1.02E+01 6.50E+00 2.302+01 SWL-3 L3458-03 29 Sb- 124 4.00E-01 2.00E+00 7.00E+00 SWL-3 U2458-03 29 Sb- 125 2.00E-01 1.702+00 5.90E+00 SWL-3 W3458-03 29 Se-75 -7.90E-01 9.00E-01 3.10E+00 SWL-3 U3458-03 29 Zn-65 1.OOE-01 2.302+00 7.802+00 -
SWL-3 L3458-03 29 Zr-95 1.30E+00 1.30E+00 4.30E+00 SWL-1 L3732-01 33 Acll-228 -8.00E-01 3.60E+00 1.202+01 SWL-1 L3732-01 33 Ag-108m -3.70E-01 5.60E-01 1.90E+00 SWL-1 L3732-01 33 Ag-I lOm -1.20E+00 1.00+00 3.60E+00 SWL-1 L3732-01 33 Ba-140 -2.80E+00 2.90E+00 1. O10+01 SWL-- L3732-01 33 Be-7 2.50E+00 6.90E+00 2.402+01 SWL-I L3732-01 33 Ce- 141 -7.OOE-01 2.40E+00 8.00E+00 SWL-I L3732-01 33 Ce-144 -1.28E+01 6.20E+00 2.20E+01 SWL-1 L3732-01 33 Co-57 -6.00E-01 5. 10E-0I 1.80E+00 SWL-I L3732-01 33 Co-58 5.40E-01 7.90E-01 2.70E+00 SWL-I L3732-01 33 Co-60 1.11 E+00 7.302-01 2.40E+00 SWL-1 L3732-01 33 Cr-51 -6.00E+00 1.002+01 3.50E+01 SWL- I L3732-01 33 Cs- 134 -1.30E-01 6.60E-01 2.30E+00 SWL-I L3732-01 33 Cs- 137 -9.50E-OI 7.20E-01 2.602+00 SWL-I L3732-01 33 Fe-59 1.IOE+00 2.40E+00 8.40E+00 SWL- I L3732-01 33 1-131 1.IOE+00 6.40E+00 2.20E+01 SWL-I L3732-01 33 K-40 1.OOE+00 1.20E+01 4.20E+01 SWL-I L3732-01 33 La-140 -3.20E+00 3.40E+00 1.20E+01
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-240
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
SWL-I L3732-01 33 Mn-54 -6.30E-01 7.30E-01 2.60E+00 SWL-I L3732-01 33 Nb-95 -1.40E+00 L.OOE+00 3.70E+00 SWL-I L3732-01 33 Ru-103 -1.83E+00 9.70E-01 3.50E+00 SWL-I L3732-01 33 Ru-106 -2.30E+00 6.50E+00 2.20E+0O SWL-I L3732-01 33 Sb-124 -2.40E+00 2.OOE+00 7.60E+00 SWL-I L3732-01 33 Sb-125 2.30E+00 1.80E+00 5.90E+00 SWL-I L3732-01 33 Se-75 -3.30E-01 9.80E-01 3.30E+00 SWL-I L3732-01 33 Zn-65 2.80E+00 2.10E+00 6.70E+00 SWL-I L3732-01 33 Zr-95 3.OOE+00 1.40E+00 4.50E+00 SWL-2 L3732-02 33 AcTh-228 -I.IOE+0O 3.70E+00 1.30E+0O SWL-2 L3732-02 33 Ag-108m 5.20E-01 7.70E-01 2.60E+00 SWL-2 L3732-02 33 Ag-I lOm -2.OOE-01 1.30E+00 4.70E+00 SWL-2 L3732-02 33 Ba-140 3.60E+00 3.50E+00 1.20E+0O SWL-2 L3732-02 33 Be-7 -7.30E+00 9.20E+00 3.20E+01 SWL-2 L3732-02 33 Ce-141 -2.IOE+00 1.70E+00 5.90E+00 SWL-2 L3732-02 33 Ce-144 2.50E+00 5.40E+00 1.80E+0O SWL-2 L3732-02 33 Co-57 I.IOE-01 6.90E-01 2.30E+O0 SWL-2 L3732-02 33 Co-58 -5.OOE-0O I.IOE+0O 3.90E+00 SWL-2 L3732-02 33 Co-60 6.70E-01 9.90E-01 3.40E+00 SWL-2 L3732-02 33 Cr-SI 1.60E+01 1.40E+01 4.60E+01 SWL-2 L3732-02 33 Cs-134 1.IOE+00 9.80E-01 3.30E+00 SWL-2 L3732-02 33 Cs-137 -4.80E-01 9.80E-01 3.50E+00 SWL-2 L3732-02 33 Fe-59 -2.OOE-01 3.OOE+00 I.IOE+0O SWL-2 L3732-02 33 1-131 2.80E+00 8.10E+00 2.70E+OI SWL-2 L3732-02 33 K-40 -2.OOE+00 1.50E+01 5.20E+01 SWL-2 L3732-02 33 La-140 4.10E+00 4.OOE+00 1.40E+01 SWL-2 L3732-02 33 Mn-54 -I.O1E+00 9.80E-01 3.50E+00 SWL-2 L3732-02 33 Nb-95 -2.10E+00 1.50E+00 5.50E+00 SWL-2 L3732-02 33 Ru-103 -1.40E+00 1.60E+00 5.80E+00 SWL-2 L3732-02 33 Ru-106 -8.OOE-01 9.1OE+00 3.20E+0O SWL-2 L3732-02 33 Sb-124 1.70E+00 2.70E+00 9.40E+00 SWL-2 L3732-02 33 Sb-125 1.60E+00 2.30E+00 7.90E+00 SWL-2 L3732-02 33 Se-75 -5.OOE-01 1.30E+00 4.40E+00 SWL-2 L3732-02 33 Zn-65 -3.50E+00 2.20E+00 8.1OE+00 SWL-2 L3732-02 33 Zr-95 -1.80E+00 1.80E+00 6.40E+00 SWL-3 U3732-03 33 AcTh-228 6.20E+00 2.1OE+00 6.70E+00 SWL-3 U3732-03 33 Ag-108m -I.OOE-0I 4.60E-01 1.60E+O0 SWL-3 12732-03 33 Ag-I lOm -2.50E-01 7.80E-01 2.70E+00 SWL-3 12732-03 33 Ba-140 2.30E+00 2.40E+00 8.OOE+00 SWL-3 L3732-03 33 Be-7 1.06E+01 6.OOE+00 2.OOE+OI
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-241
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
SWL-3 L3732-03 33 Ce-141 5.OOE-01 I1.30E+00 4.20E+00 SWL-3 L3732-03 33 Cc-144 3.30E+00 3.101E+00 1.OOE+01 SWL-3 L3732-03 33 Co-57 -4.OOE-01 6.101E-01 2.10E+00 SWL-3 L3732-03 33 Co-58 4.60E-01 6.40E3-01 2.20E3+00 SWL-3 L3732-03 33 Co-60 1.20E-01 5.50E-01 I1.90E+00 SWL-3 W3732-03 33 Cr-51 2.40E+00 8.301E+00 2.80E+01 SWL-3 W3732-03 33 Cs-134 7.00E-02 5.60E-01 1.901E+00 SWL-3 L3732-03 33 Cs-137 7.20E-01 5.901E-01 2.OOE+00 SWL-3 L3732-03 33 Fe-59 2.00E-01 2.20E3+00 7.60E+00 SWL-3 L3732-03 33 1-131 3.101E+00 7.801E+00 2.60E+01 SWL-3 W3732-03 33 K-40 -1.I1OE+01 1.1OE+01 4.OOE-i-01 SWL-3 W3732-03 33 La- 140 2.60E+00 2.70E3+00 9.20E+00 SWL-3 L3732-03 33 Mn-54 -1.90E-01 5.301E-01 I1.8013-00 SWL-3 L3732-03 33 Nb-95 -6.00E-01 1.30E+00 4.30E3+00 SWL-3 L3732-03 33 Ru-103 -3.70E-01 8.10E-01 2.801E+00 SWL-3 L3732-03 33 Ru-106 4.101E+00 5.80E+00 1.901E+01 SWL-3 L3732-03 33 Sb-124 1.90E+00 I1.701E+00 5.70E+00 SWL-3 L3732-03 33 Sb-125 -2.10E+00 1.401E+00 4.90E+00 SWL-3 L3732-03 33 Se-75 -2.60E-01 6.60E3-01 2.30E+00 SWL-3 W3732-03 33 Zn-65 3.40E+00 1.80E+00 5.60E+00 SWL-3 13732-03 33 Zr-95 -1.40E+00 I1.20E+00 4.30E3+00 SWL-1 L3951-01 38 AcTh-228 4.OOE-01 3.80E+00 1.40E+01 SWL-I 13951-01 38 Ag- 108m O.OOE+00 7.60E3-01 2.70E+00 SWL-I L3951-01 38 Ag-i lOIm 1.20E+00 1.40E-,-00 4.801E+00 SWL-1 L3951-01 38 Ba-140 1.30E+00 3.201E+00 I1.20E3+01 SWL- I L3951-01 38 Be-7 -2.30E+00 9.80E+00 3.601E+01 SWL-l 13951-01 38 Ce-141 -3.80E+00 2.40E+00 8.70E+00 SWL-I L3951-01 38 Ce-144 2.30E+00 6.80E+00 2.30E+01 SWL-I L3951-01 38 Co-57 -1.80E-01 9.201E-01 3.20E+00 SWL-1 L3951-01 38 Co-58 -2.00E-01 1.101E+00 4.OOE+00 SWL-l L3951-01 38 Co-60 7.00E-01 1.OOE1,-00 3.60Ei-00 SWL-I L3951-01 38 Cr-51 -I.OOE+00 1.301E+01 4.701E+01 SWL-1 L3951-01 38 Cs-134 -6.00E-02 8.701E-01 3.30E+00 SWL- 1 L3951-01 38 Cs-137 -6.00E-01 1.OOE3+00 3.801E+00 SWL- I L3951-01 38 Fe-59 1.60E+00 3.OOE+00 1.IOE+01 SWL-I W3951-01 38 1-131 3.30E+00 6.70E+00 2.30E+01 SWL-I W3951-01 38 K-40 -1.90E+01 I1.201E+01 5.OOE+01 SWL-I W3951-01 38 La-140 1.50E+00 3.70E+00 1.401E+01
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-242
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
SWL-I L3951-01 38 Mn-54 9.50E-01 9.70E-01 3.30E+00 SWL-I L3951-01 38 Nb-95 2.OOE-01 1.40E+O0 5.IOE+00 SWL-I L3951-01 38 Ru-103 -1.20E+00 1.30E+00 4.80E+O0 SWL-I L3951-01 38 Ru-106 4.30E+00 8.IOE+00 2.90E+0l SWL-I L3951-01 38 Sb-124 -3.90E+00 2.80E+00 1.20E+0I SWL-I L3951-01 38 Sb-125 -I.IOE+00 2.50E+00 9.10E+00 SWL-I L3951-01 38 Se-75 I.OOE-01 1.50E+00 -5.20E+00 SW-1I L3951-O1 38 Zn-65 4.20E+00 3.80E+00 1.30E+01 SWL-I L3951-01 38 Zr-95 1.OOE+00 1.80E+00 6.30E+00 SWL-2 L3951-02 38 AcTh-228 3.80E+00 3.20E+00 1.IOE+01 SWL-2 L3951-02 38 Ag-108m 3.80E-01 7.80E-01 2.70E+00 SWL-2 L3951-02 38 Ag-i lOm -9.OOE-01 1.20E+00 4.70E+00 SWL-2 L3951-02 38 Ba-140 I.OOE+O0 3.50E+00 1.30E+01 SWL-2 L3951-02 38 Be-7 -5.90E+00 9.10E+00 3.50E+0I SWL-2 L3951-02 38 Ce-141 -I.OOE+00 2.30E+00 8.OOE+00 SWL-2 L3951-02 38 Ce-144 3.60E+00 6.70E+00 2.30E+01 SWL-2 L3951-02 38 Co-57 8.90E-01 8.50E-01 2.90E+00 SWL-2 L3951-02 38 Co-58 2.1OE-01 9.30E-01 3.40E+00 SWL-2 L3951-02 38 Co-60 3.50E-01 8.10E-01 3.OOE+O0 SWL-2 L3951-02 38 Cr-51 -1.OOE+OO 1.30E+01 4.60E+0I SWL-2 L3951-02 38 Cs-134 1.40E+00 I.IOE+00 3.80E+00 SWL-2 L3951-02 38 Cs-137 -1.60E-01 9.30E-01 3.50E+00 SWL-2 L3951-02 38 Fe-59 1.30E+00 2.60E+00 9.80E+00 SWL-2 L3951-02 38 1-131 -8.20E+00 6.70E+00 2.50E+01 SWL-2 L3951-02 38 K-40 -2.00E+00 1.20E+01 4.50E+01 SWL-2 L3951-02 38 La-140 1.20E+00 4.OOE+00 1.50E+01 SWL-2 L3951-02 38 Mn-54 -8.OOE-01 8.90E-01 3.50E+00 SWL-2 L3951-02 38 Nb-95 -1.20E+00 1.50E+00 5.80E+00 SWL-2 L3951-02 38 Ru-103 -3.OOE-01 1.30E+00 4.90E+00 SWL-2 L3951-02 38 Ru-106 -1.57E+01 9.70E+00 3.80E+0I SWL-2 L3951-02 38 Sb-124 3.50E+00 2.50E+00 8.30E+00 SWL-2 L3951-02 38 Sb-125 4.1OE+00 2.50E+00 8.30E+00 SWL-2 L3951-02 38 Se-75 -9.OOE-01 1.30E+00 4.60E+00 SWL-2 L3951-02 38 Zn-65 -3.00E-01 2.70E+00 9.80E+00 SWL-2 L3951-02 38 Zr-95 I.OOE+O0 2.20E+00 7.80E+00 SWL-3 L3951-03 38 Aclb-228 3.30E+00 3.50E+00 1.20E+01 SWL-3 L3951-03 38 Ag-108m 6.30E-01 9.OOE-01 3.1OE+OO SWL-3 L3951-03 38 Ag-I lOm -1.OOE+OO 1.30E+00 4.80E+OO SWL-3 L3951-03 38 Ba-140 I.IOE+00 3.20E+00 1.20E+01 SWL-3 L3951-03 38 Be-7 -3.90E+00 9.30E+00 3.40E+01
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-243
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
SWL-3 L3951-03 38 Cc-141 -3.00E-01 2.60E+00 9.10E+00 SWL-3 L3951-03 38 Ce-144 -2.00E-01 7.40E3+00 2.60E+01 SWL-3 L3951-03 38 Co-57 l.OE-01 9.40E-01 3.20E+00 SWL-3 L3951-03 38 Co-58 -1.60E+00 1.20E+00 4.60E+00 SWL-3 L3951-03 38 Co-60 3.00E-01 1.10+00 4.00E+00 SWL-3 L3951-03 38 Cr-5 1.80E+01 1.50E+01 4.90E+01 SWL-3 L3951-03 38 Cs- 134 3.20E-01 9.OOE-01 3.20E+00 SWL-3 L3951-03 38 Cs-137 -2.20E+00 1.OOE+00 4.10E+00 SWL-3 L3951-03 38 Fe-59 4.80E+00 3.OOE+00 9.80E+00 SWL-3 L3951-03 38 1-131 1.20E+01 7.20E+00 2.40E+01 SWL-3 L3951-03 38 K-40 -1.40E+01 1.1OE+01 4.50E+01 SWL-3 L3951-03 38 La-140 1.30E+00 3.70E+00 1.40E+01 SWL-3 L3951-03 38 Mn-54 -4.70E-01 9.70E-01 3.60E+00 SWL-3 L3951-03 38 Nb-95 -2.OOE-0I 2.30E+00 8.10E+00 SWL-3 L3951-03 38 Ru-103 1.40E+00 1.40E+00 4.70E+00 SWL-3 L3951-03 38 Ru-106 2.10E+00 9.20E+00 3.30E+01 SWL-3 L3951-03 38 Sb-124 -6.30E+00 2.502+00 1.102+01 SWL-3 L3951-03 38 Sb-125 2.00E+00 2.70E+00 9.20E+00 SWL-3 L3951-03 38 Se-75 -1.60E+00 1.40E+00 5.20E+00 SWL3 L3951-03 38 Zn-65 7.20E+00 4.30E+00 1.40E+01 SWL-3 L3951-03 38 Zr-95 -9.00E-01 1.70E+00 6.50E+00 SWL-- L3951-04 38 H-3 -2.60E+02 5.OOE+02 1.50E+03 SWL-2 L3951-05 38 H-3 -3.90E+02 4.90E+02 1.50E+03 SWL-3 L3951-06 38 H-3 4.80E+02 5.40E+02 1.60E+03 SWL-' L4232-01 42 AcTh-228 -2.00E+00 3.40E+00 1.20E+01 SWL-I L4232-01 42 Ag-108m 2.30E-01 4.70E-01 1.60E+00 SWL-I L4232-01 42 Ag-I lrOm -4.00E-02 7.80E-01 2.70E+00 SWL-1 L4232-01 42 Ba-140 1.90E+00 2.40E+00 8.10E+00 SWL-1 L4232-01 42 Be-7 5.80E+00 6.30E+00 2.10E+01 SWL-' L4232-01 42 Ce-141 -3.00E-01 1.50E+00 5.00E+00 SWL-1 L4232-01 42 Ce-144 -1.00E+00 3.40E+00 1.1OE+01 SWL-1 L4232-01 42 Co-57 8.40E-01 4.20E-01 1.40E+00 SWL--' L4232-01 42 Co-58 -1.24E+00 6.80E-01 2.50E+00 SWL-1 L4232-01 42 Co-60 2.40E-01 5.80E-01 2.00E+00 SWL-I L4232-01 42 Cr-51 1.03E+01 8.50E+00 2.80E+01 SWL-I L4232-01 42 Cs-134 -2.OOE-02 6.10E-01 2.10E+00 SWL-I L4232-01 42 Cs-137 -1.20E+00 6.50E-01 2.30E+00 SWL-I L4232-01 42 Fe-59 -6.00E-01 1.60E+00 5.70E+00
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-244
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
SWL-1 L4232-OI 42 1-131 -2.OOE-01 5.40E+O0 1.80E+0O SWL-I L4232-01 42 K-40 1.IOE+0I LOOE+01 3.40E+01 SWL-I L4232-01 42 La-140 2.20E+O0 2.70E+00 9.30E+00 SWLI L4232-01 42 Mn-54 -4.90E-0O 5.60E-01 2.00E+00 SWL-I L4232-01 42 Nb-95 -1.30E+00 1.10E+O0 3.70E+00 SWL-I L4232-O1 42 Ru-103 8.30E-OI 8.OOE-01 2.70E+O0 SWL-1 L4232-O1 42 Ru-106 6.OOE-0O 5.80E+OO 2.OOE+01 SWL-I L4232-O1 42 Sb-124 -3.40E+O0 1.80E+00 6.70E+OO SWL-I L4232-O1 42 Sb-125 4.OOE+OO 1.50E+O0 5.OOE+0O SWL-I L4232-01 42 Se-75 6.40E-0O 7.OOE-O1 2.30E+O0 SWL-l L4232-01 42 Zn-05 5.70E+0O 2.40E+00 7.60E+O0 SWL-I L4232-01 42 Zr-95 2.OOE-OI 1.30E+OO 4.40E+00 SWL,2 L4232-02 42 AcTh-228 1.50E+O0 3.90E+OO 1.30E+01 SWL-2 L4232-02 42 Ag-lO8m 7.10E-01 5.90E-0 2.00E+00 SWL-2 L4232-02 42 Ag-llOm -5.00E-OI I.OOE+O0 3.50E+O0 SWL-2 L4232-02 42 Ba-140 -1.50E+O0 2.90E+00 L.1OE+0O SWL-2 L4232-02 42 Be-7 -1.77E+0O 7.30E+OO 2.60E+0O SWL-2 L4232-02 42 Ce-141 2.70E+00 1.50E+OO 4.90E+00 SWL-2 L4232-02 42 Ce-144 6.60E+O0 4.OOE+O0 1.30E+0O SWL-2 L4232-02 42 Co-57 -2.00E-02 5.20E-0O 1.70E+O0 SWL-2 L4232-02 42 CO-58 -7.101E-01 7.80E-0O 2.80E+O0 SWL-2 L4232-02 42 Co-60 1.07E+O0 7.OOE-0 2.30E+O0 SWL-2 L4232-02 42 Cr-51 I.OOE+0O L.OOE+O1 3.40E+01 SWL-2 L4232-02 42 Cs-134 3.90E-0O 6.70E-O1 2.30E+00 SWL-2 L4232-02 42 Cs-137 1.60E-01 7.20E-0 2.50E+OO SWL-2 L4232-02 42 Fe-59 2.40E+O0 1.90E+O0 6.30E+00 SWL-2 L4232-02 42 1-131 9.20E+00 6.20E+OO 2.OOE+01 SWL-2 LA232-02 42 K-40 1.50E+0O 1.20E+01 4.00E+01 SWL-2 L4232-02 42 La-140 -1.70E+OO 3.40E+00 1.20E+0O SWL-2 L4232-02 42 Mn-54 -6.80E-01 6.80E-01 2.40E+O0 SWL-2 L4232-02 42 Nb-95 -3.10E+O0 1.40E+00 5.IOE+00 SWL-2 L4232-02 42 Ru-103 4.30E-OI 9.60E-O1 3.30E+00 SWL-2 L4232-02 42 Ru-106 -4.20E+OO 6.70E+O0 2.30E+01 SWL-2 L4232-02 42 Sb-124 -6.00E-01 1.80E+00 6.40E+O0 SWL-2 L4232-02 42 Sb-125 O.OOE+00 1.80E+00 6.20E+00 SWL-2 L4232-02 42 Se-75 8.30E-01 9.70E-01 3.20E+OO SWL-2 L4232-02 42 Zn-65 -1.OOE-0O 2.1OE+OO 7.20E+OO SWL-2 L4232-02 42 Zr-95 -1.10E+00 1.40E+OO 4.90E+OO SWL-3 L4232-03 42 AcTh-228 -6.OOE-01 2.90E+00 L.OOE+OI SWL-3 L4232-03 42 Ag-108m 8.OOE-02 5.70E-01 2.OOE+00
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-245
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
SWL-3 L4232-03 42 Ag-l1lm O.OOE+O0 9.60E-01 3.30E+00 SWL-3 L4232-03 42 Ba-140 -3.60E+00 2.90E+00 1.IOE+O1 SWL-3 L4232-03 42 Be-7 -9.30E+00 7.20E+00 2.60E+01 SWL-3 L4232-03 42 Ce-141 1.OOE+00 1.60E+00 5.30E+00 SWL-3 L4232-03 42 Ce-144 -1.20E+00 4.20E+00 1.40E+01 SWL-3 L4232-03 42 Co-57 -3.30E-01 5.40E-01 1.80E+00 SWL-3 L4232-03 42 Co-58 -1.04E+00 7.90E-01 2.80E+00 SWL-3 L4232-03 42 Co-60 1.80E-01 7.60E-01 2.60E+00 SWL-3 L4232-03 42 Cr-SI 6.40E+00 9.90E+00 3.30E+O1 SWL-3 L4232-03 42 Cs-134 -6.30E-01 8.00E-01 2.80E+00 SWL-3 L4232-03 42 Cs-137 -1.40E-01 7.40E-01 2.60E+00 SWL-3 L4232-03 42 Fe-59 0.OOE+00 2.00E+00 7.00E+00 SWL-3 L4232-03 42 1-131 0.OOE+00 6.00E+00 2.OOE+01 SWL-3 L4232-03 42 K-40 -1.70E+01 1.IOE+01 4.00E+01 SWL-3 L4232-03 42 La-140 -4.20E+00 3.40E+00 1.20E+01 SWL-3 L4232-03 42 Mn-54 8.70E-01 7.20E-01 2.40E+00 SWL-3 L4232-03 42 Nb-95 1.OOE-0O 1.30E+00 4.30E+00 SWL-3 L4232-03 42 Ru-103 3.30E-01 9.70E-01 3.30E+00 SWL-3 L4232-03 42 Ru-106 1.47E+01 6.40E+00 2.10E+01 SWL-3 L4232-03 42 Sb-124 -1.40E+00 2.20E+00 8.OOE+00 SWL-3 L4232-03 42 Sb-125 -2.20E+00 1.80E+00 6.30E+00 SWL-3 L4232-03 42 Se-75 I.01E+OO 9.60E-01 3.20E+OO SWL-3 L4232-03 42 Zn-65 7.50E+00 2.70E+00 8.602+00 SWL-3 L4232-03 42 Zr-95 4.00E-01 1.402+00 4.70E+OO SWL-I L4438-01 46 AcTh-228 1.30E+00 3.10E+00 1.10E+01 SWL-l L4438-01 46 Ag-108m 6.OOE-01 5.20E-01 1.70E+00 SWL-1 L4438-01 46 Ag-I lOnm -2.OOE-01 9.OOE-01 3.10E+00 SWL-I L4438-01 46 Ba-140 4.20E+00 2.20E+00 7.10E+00 SWL-I L4438-01 46 Be-7 -1.IOE+00 6.00E+00 2.002+01 SWL-I L4438-01 46 Ce-141 1.40E+00 1.80E+00 5.90E+00 SWL-1 L4438-01 46 Ce-144 3.30E+00 3.80E+00 1.30E+01 SWL-I L4438-01 46 Co-57 O.OOE+00 4.90E-01 1.70E+00 SWL-1 L4438-01 46 Co-58 8.00E-02 7.70E-01 2.60E+00 SWL-1 L4438-01 46 Co-60 -3.40E-01 7.60E-01 2.60E+00 SWL-1 L4438-01 46 Cr-SI O.OOE+00 8.70E+00 2.90E+01 SWL-1 L4438-01 46 Cs-134 -8.00E-02 7.00E-01 2.40E+00 SWL-l L4438-01 46 Cs-137 -1.60E-01 6.80E-01 2.30E+00 SWL-I L4438-01 46 Fe-59 2.10E+00 1.60E+00 5.40E+00
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-246
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
SW'-' L4438-01 46 1-131 -8.20E+00 4.40E+00 1.60E+0O SWL-1 L4438-01 46 K-40 -5.OOE+00 1.OOE+0O 3.60E+01 SWL-1 L4438-01 46 La-140 4.90E+00 2.50E+00 8.10E+00 SWL-I L4438-01 46 Mn-54 -4.50E-0O 6.60E-01 2.30E+00 SWL-I L4438-01 46 Nb-95 -1.30E+00 1.20E+00 4. IOE+00 SWL-I L4438-01 46 Ru-103 -3.73E+00 8.40E-01 3. IOE+00 SWL-- L4438-01 46 Ru-106 -8.20E+00 6.20E+00 2.20E+01 SWL-I L4438-01 46 Sb-124 -2.10E+00 l .90E+00 7. IOE+00 SWL-' L4438-01 46 Sb-125 3.OOE+00 1.60E+00 5.20E+00 SWL-t L4438-01 46 Se-75 9.10E-01 8.70E-0O 2.90E+00 SWL-I L4438-01 46 Zn-65 2.OOE-0O 2.30E+00 7.70E+00 SWL'- L4438-01 46 Zr-95 8.OOE-0O 1.20E+00 4.OOE+00 SWL-2 L4438-02 46 AcTh-228 -3.50E+00 3.40E+00 1.20E+0O SWL-2 L4438-02 46 Ag-108m 1.20E-01 5.80E-0I 2.OOE+00 SWL-2 L4438-02 46 Ag-l lOIm -3.60E-01 9.OOE-0O 3.20E+00 SWL-2 L4438-02 46 Ba-140 3.OOE+00 2.50E+00 8.40E+00 SWL-2 L4438-02 46 Be-7 5. 1OE+00 6.80E+00 2.30E+0O SWL-2 L4438-02 46 Ce-141 8.OOE-01 1.60E+00 5.30E+00 SWL-2 L4438-02 46 Ce-144 -1.30E+00 3.90E+00 1.30E+0O SWL-2 L4438-02 46 Co-57 5.80E-01 5.OOE-01 1.70E+00 SWL-2 L4438-02 46 Co-58 5.80E-01 7.40E-0I 2.50E+00 SWL-2 L4438-02 46 Co-60 -6.OOE-02 6.60E-01 2.30E+00 SWL-2 L4438-02 46 Cr-51 -1.20E+O0 9.20E+00 3.20E+01 SWL-2 L4438-02 46 Cs-134 3.90E-0O 7.40E-0O 2.50E+00 SWL-2 L4438-02 46 Cs-137 -1.20E+00 7.20E-01 2.60E+00 SWL-2 L4438-02 46 Fe-59 1.40E3+00 1.70E+00 5.80E+00 SWL-2 L4438-02 46 1-131 -1.40E+00 4.60E+00 1.60E+01 SWL-2 L4438-02 46 K-40 -8.OOE+O0 1.30E+0O 4.40E+0O SWL-2 L4438-02 46 La-140 3.50E+00 2.90E+00 9.60E+00 SWL-2 L4438-02 46 Mn-54 -8.60E-01 6.30E-0O 2.30E+00 SWL-2 L4438-02 46 Nb-95 - 1.50E+00 1.lOE+00 3.90E+00 SWL-2 L4438-02 46 Ru-103 -2.05E+00 9.70E-0O 3.50E+00 SWL-2 L4438-02 46 Ru-106 -6.40E+00 6.50E+00 2.30E+01 SWL-2 L4438-02 46 Sb-124 -1.70E+00 2.OOE+00 7.40E+00 SWL-2 L4438-02 46 Sb- 125 -8.OOE-0O 1.80E+00 6.30E+00 SWL-2 U4438-02 46 Se-75 -7.00E-02 7.80E-01 2.70E+00 SWL-2 UA438-02 46 Zn-65 2.OOE-01 2.10E+O0 7. IOE+00 SWL-2 L4438-02 46 Zr-95 4.OOE-01 I.50E+00 5.30E+00 SWL-3 L4438-03 46 AcTh-228 4.40E+O0 3.50E+00 1.40E+01 SWL-3 L4438-03 46 Ag-108m -4.40E-0O 6.40E-0O 2.20E+00
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-247
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCilkg) (pCi/kg)
SW[-3 L4438-03 46 Ag- lOim -8.0OE-01 1.20E+00 4.20E+00 SWL-3 L4438-03 46 Ba-140 -2.50E+00 2.90E-e00 1.lOE+0O SWL-3 L4438-03 46 Be-7 8. 1OE+O0 8.50E+00 2.80E+0O SWL-3 L4438-03 46 Ce-141 -1 .20E+O0 1 .70E+00 5.90E+00 SWL-3 L4438-03 46 Ce-144 -I1.26E+0l 5.40E+00 l.90E+0O SWL-3 L4438-03 46 Co-57 5.40E-01 6.70E-01 2.20E+00 SWL-3 L4438-03 46 Co-58 -7.20E-01 9.20E-01 3.20E+00 SWL-3 L4438-03 46 Co-60 -3.OOE-02 8.10OE-01 2.80E+00 SWL-3 L4438-03 46 Cr-SI -1 .50E-i01 1.10E+01 3.90E+01 SWL-3 L4438-03 46 Cs-134 1.66E+O0 8.50E-01 2.80E+00 SWL-3 L4438-03 46 Cs-137 8.70E-01 8.30E-01 2.80E+00 SWL-3 L4438-03 46 Fe-59 3.90E+00 2.OOE+00 6.50E+00 SWL-3 L4438-03 46 1-131 5.50E+00 5.50E+00 1.80E+01 SWL-3 L4438-03 46 K-40 -1 .90E+01 1.30E-i0I 4.70E+01 SWL-3 L4438-03 46 La-140 -2.90E+00 3.30E+00 1.20E+01 SWL-3 L4438-03 46 Mn-54 1.50E-01 8.30E-01 2.80E+00 SWL-3 L4438-03 46 Nb-95 1.70E+00 I1.20E+O0 3.80E+00 SWL-3 L4438-03 46 Ru-103 -1 .70E-i00 1.20E+00 4.10E+00 SWL-3 U4438-03 46 Ru-106 -1.12E+01 7.60E+00 2.70E+0O SWL-3 L4438-03 46 Sb-124 9.OOE-01 2.30E+00 8.10E+00 SWL-3 L4438-03 46 Sb-125 2.70E+00 2.OOE+00 6.60E+00 SWL-3 L4438-03 46 Se-75 1.90E+00 1.20E+00 3.80E+00 SWL-3 L4438-03 46 Zn-65 -2.10OE+00 2.60E+00 9.20E+00 SWL-3 L4438-03 46 Zr-95 1.70E+00 1.60E+00 5.40E+O0 SWL-1 L4590-01 51 AcTh-228 2.60E+00 3.10E+00 1.00E+01 SWL-1 U4590-01 51 Ag-108m O.OOE+00 6.40E-0O 2.20E+O0 SWL-1 L4590-01 51 Ag-I lOm -1.80E+00 1.IOE+00 3.90E+00 SWL-1 LA590-01 51 Ba-140 -1.40E+00 1.90E+00 6.90E+00 SWL-I U4590-01 51 Be-7 -3.90E+00 6.90E+00 2.40E+01 SWL-I UA590-01 51 Ce-141 1.30E+00 2.1OE+00 6.80E+-O SWL-I UA590-01 51 Ce-144 3.80E+00 4.70E+O0 1.60E+01 SWL-I L4590-01 51 Co-57 1.04E+00 6.10E-0O 2.OOE+00 SWL-1 L4590-01 51 Co-58 3.50E-01 8.50E-01 2.90E+00 SWL-1 L4590-01 51 Co-60 4.70E-01 9.10E-0O 3. 1OE+00 SWL-1 L4590-01 51 Cr-SI 6.50E+00 9.50E+00 3.20E+01 SWL-1 U4590-01 51 Cs-134 1.41E+00 8.60E-01 2.80E+00 SWL-1 U4590-01 51 Cs-137 -1.52E+00 8.10E-0O 2.90E+00 SWL-1 L4590-01 51 Fe-59 2.70E+00 2.10E+00 6.80E+00
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-248
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
SWL-1 LA590-01 51 1-131 -2.OOE+00 3.40E+00 1.20E+0O SWL-1 L4590-01 51 K-40 -3.00E+00 1.40E+01 4.70E+0O SWL-1 L4590-01 51 La-140 -1.60E+00 2.20E+00 8.OOE+00 SWL-1 L4590-01 51 Mn-54 -1.33E+00 7.90E-01 2.90E+00 SWL-I L4590-01 51 Nb-95 -8.00E-01 1.20E+00 4.30E+00 SWL-1 L4590-01 51 Ru-103 -1.28E+00 9.60E-01 3.40E+00 SWL-1 L4590-01 51 Ru-106 5.80E+00 7.70E+00 2.60E+0O SWL-I L4590-01 51 Sb-124 5.70E+00 2.10E+00 6.30E+00 SWL-I L4590-01 51 Sb-125 3.OOE-01 2.IOE+00 7.20E+00 SWL-1 L4590-01 51 Se-75 -7.OOE-0 I.IOE+00 3.60E+00 SWL-1 L4590-01 51 Zn-65 -1.40E+00 2.70E+00 9.40E+00 SWL-1 L4590-01 51 Zr-95 I.OOE+00 1.40E+00 4.80E+00 SWL-2 L4590-02 51 Ach-228 -1.30E+00 3.80E+00 1.30E+0O SWL-2 L4590-02 51 Ag-108m -5.20E-01 5.50E-01 I.90E+00 SWL-2 L4590-02 51 Ag-l lOm -6.OOE-02 9.60E-01 3.30E+00 SWL-2 L4590-02 51 Ba-140 -2.OOE-01 1.70E+00 6.10E+00 SWL-2 L4590-02 51 Be-7 -3.20E+00 6.40E+00 2.20E+01 SWL-2 L4590-02 51 Ce-141 -8.OOE-01 2.OOE+00 6.80E+00 SWL-2 UA590-02 51 Ce-144 -9.80E+00 3.80E+00 1.30E+01 SWL-2 U4590-02 51 Co-57 -5.60E-0O 5.OOE-0 1.70E+00 SWL-2 UA590-02 51 Co-58 4.10E-01 6.90E-01 2.30E+00 SWL-2 14590-02 51 Co-60 1.20E-01 7.80E-01 2.70E+00 SWL-2 4590-02 51 Cr-51 1.60E+00 8.30E+00 2.80E+0O SWL-2 U4590-02 51 Cs-134 -5.70E-01 6.80E-01 2.40E+00 SWL-2 L4590-02 51 Cs-137 6.OOE-02 7.10E-01 2.40E+00 SWL-2 L4590-02 51 Fe-59 1.30E+00 1.60E+00 5.30E+00 SWL-2 UA590-02 51 1-131 8.00E-01 2.90E+00 9.90E+00 SWL-2 L4590-02 51 K-40 3.OOE+00 1.20E+01 3.90E+01 SWL-2 14590-02 51 La-140 -2.0OE-01 2.00E+00 7.00E+00 SWL-2 14590-02 51 Mn-54 8.OOE-02 6.70E-01 2.30E+00 SWL-2 14590-02 51 Nb-95 3.80E-01 8.40E-01 2.90E+00 SWL-2 14590-02 51 Ru-103 -1.04E+00 8.30E-01 2.90E+00 SWL-2 LA590-02 51 Ru-106 -1.80E+00 6.60E+00 2.30E+01 SWL-2 LA590-02 51 Sb-124 3.OOE-01 1.80E+00 6.50E+00 SWL-2 LA590-02 51 Sb-125 3.OOE-01 1.80E+00 6.10E+00 SWL-2 UA590-02 51 Se-75 -1.43E+00 8.90E-01 3.101E+00 SWL-2 14590-02 51 Zn-65 -1.70E+00 1.90E+00 6.80E+00 SWL-2 14590-02 51 Zr-95 - 1.50E+00 1.30E+00 4.60E+00 SWL-3 L4590-03 51 AcTh-228 -3.40E+00 3.50E+00 1.20E+0O SWL-3 14590-03 51 Ag-108m -9.OOE-02 5.90E-01 2.OOE+00
- Radioactivity detected in sample (i.e., concentration > 3 X standard deviation)
D-249
Indiana Michigan Power Co., DC Cook Nuclear Plant Radiological Environmental Monitoring Program Summary of 2002 Data Media Station LSN Week Nuclide Conc Std. Dev. MDC (pCi/kg) (pCi/kg) (pCi/kg)
SWL-3 L4590-03 51 Ag-i lOm -5.50E-01 9. 10E-01 3.30E+O0 SWL-3 L4590-03 51 Ba-140 L.OOE-01 1.80E+00 6.40E+O0 SWL-3 L4590-03 51 Be-7 -l . IE+00 6.40E+00 2.20E+01 SWL-3 L4590-03 51 Ce-141 -6.90E+00 2.IOE+00 7.30E+00 SWL-3 L4590.03 51 Ce- 144 -3.70E+00 3.90E+00 1.40E+01 SWL-3 L4590-03 51 Co-57 -8.20E-01 5.OOE-01 I1.70E+00 SWL-3 LA590-03 51 Co-58 I1.24E+00 7.OOE-01 2.30E+00 SWL-3 L4590-03 51 Co-60 -1.53E+00 7.80E-01 2.90E+00 SWL-3 L4590-03 51 Cr-51 4.40E+O0 8.70E+00 2.90E+01 SWL-3 LA590-03 51 Cs- 134 1.41E+O0 7.40E-01 2.40E+00 SWL-3 LA590-03 51 Cs-137 6.OOE-02 7.80E-01 2.70E+00 SWL-3 L4590-03 51 Fe-59 5.OOE-01 I1.60E+00 5.50E+00 SWL-3 L4590-03 51 1-131 2.20E-i0O 3. IOE+00 I.OOE+01 SWL-3 L4590-03 51 K-40 6.OOE+00 1.20E+01 4.I1OE+01 SWL-3 L4590-03 51 La-140 1LOOE-01 2.10OE+00 7.40E+00 SWL-3 L4590-03 51 Mn-54 4.90E-01 6.80E-01 2.30E+O00 SWL-3 L4590-03 51 Nb-95 -5.50E-01 9.OOE-01 3.20E+00 -
SWL-3 L4590-03 51 Ru-103 -1.31IE+00 8.60E-01 3.I1OE-i00 SWL-3 LA590-03 51 Ru-106 -3.1OE+00 7.I1OE+00 2.50E+01 SWL-3 1A590-03 51 Sb-124 -1.20E+00 2.20E-e00 7.90E+00 SWL-3 LA590-03 51 Sb-125 -6.20E+00 1.80E-+OO 6.60E+00 SWL-3 L4590-03 51 Se-75 -5.50E-01 8.OOE-01 2.80E+O0 SWL-3 L4590-03 51 Zn-65 -1.90E-u0O 1.60E+00 5.90E+00 SWL-3 L4590-03 51 Zr-95 L.OOE+00 1.40E+00 4.80E+00 SWL-1 LA590-04 51 H-3 I1.20E+02 4.30E+02 1.30E+03 SWL-2 L4590-05 51 H-3 -5.60E+02 4.20E+02 I1.30E+03 SWL-3 L4590-06 51 H-3 -5.60E+02 4.20E+02 1.30E..03
- Radioactivity detected in sample (i.e., concentration >3 X standard deviation)
D-250
DC Cook Nuclear Plant Units 1&2 Annual Radiological Environmental Operating Report 2002 APPENDIX E Pre-Operational Radiological Monitoring Program E-1
DC Cook Nuclear Plant Units 1&2 Annual Radiological Environmental Operating Report 2002 D.C. Cook Nuclear Plant I Pre-Operational Radiological Monitoring Program Summary This appendix details information obtained during the conduct of a Pre-Operational Radiological Monitoring Program (PRMP) at the D.C. Cook Nuclear plant from August 1971 until the initial criticality of Unit 1 on January 18, 1975. Program related samples were analyzed by the Eberline Instrument Corporation and a summary of these results are _
presented below. This information was utilized during the evaluation of D.C. Cook's 2002 Radiological Environmental Monitoring Program sample data and allowed for the comparison of current and historical information. -
Air Samples:
Gross beta radioactivity in PRMP air particulate filters ranged from 0.01 to 0.17 pCilm3 from mid 1971 until mid 1973. In June of 1973 and 1974, the People's Republic of China detonated several nuclear devices in the atmosphere. As a result, PRMP gross beta radioactivity results up to 0.45 pCi/m3 were documented with no statistically significant difference noted between indicator and control stations. By the end of the pre-operational period, gross beta values were approximately 0.06 pCi/m3.
Analysis of composited PRMP air particulate filters detected "trace amounts" of fission product nuclides Ce-144, Ru-103, Ru-106, Zr-95 and Nb-95. The presence of these nuclides was attributed to previously conducted atmospheric nuclear tests.
Cosmogenically produced Be-7 was also identified during the analysis of these air particulate filters.
Direct Radiation:
Direct radiation (background) as measured by PRMP thermoluminescent dosimeters ranged between 1.0 and 2.0 mRem per week.
Milk Samples:
Gamma ray spectroscopy of PRMP milk samples was conducted and naturally occurring K-40 was detected in the range of 520 to 2310 pCi/liter. Cs-137 was detected in many milk samples following the atmospheric nuclear test discussed above. Cs-137 radioactivity ranged from 8 to 33 pCi/liter. 1-131 was noted in four milk samples collected on 719/74 with values ranging from 0.2 to 0.9 pCi/liter.
Lake Water Samples:
PRMP Lake water samples collected were analyzed for tritium and by gamma ray spectroscopy. Tritium activities were below 1000 pCi/liter and typically averaged about 400 pCi/liter. No nuclides were detected by gamma ray spectroscopy.
E-2
DC Cook Nuclear Plant Units 1&2 Annual Radiological Environmental Operating Report 2002 Lake Sediment Samples:
PRMP lake sediment samples were analyzed by gamma ray spectroscopy and a natural abundance of Uranium, Thorium daughters and K-40 were detected. Traces of Cs- 137 were also noted (less than 0.1 pCi/gram) and attributed to fallout.
Fish Samples:
PRMP Fish samples collected and analyzed by gamma ray spectroscopy exhibited a natural abundance of K-40. Trace levels of Cs-137 present were attributed to fallout.
Drinking Water Samples:
Drinking water sampling and analysis was not performed as part of D.C. Cook's PRMP.
E-3