Letter Sequence Draft RAI |
---|
TAC:MB6611, Administratively Control Containment Penetrations, TSTF-68, Allow Equipment Hatch to Be Open During Fuel Movement, Revise Containment Requirements During Handling Irradiated Fuel and Core Alterations (Approved, Closed) TAC:MB6612, (Approved, Closed) |
|
MONTHYEARML0306604712003-03-0505 March 2003 Facsimile Transmission, Draft Request for Additional Information (RAI) to Be Discussed in an Upcoming Conference Call Project stage: Draft RAI ML0307300302003-03-13013 March 2003 Facsimilie Transmission, Draft Request for Additional Information to Be Discussed in an Upcoming Conference Call Project stage: Draft RAI ML0310705232003-04-17017 April 2003 Facsimile Transmission, Draft Request for Additional Information (RAI) to Be Discussed in an Upcoming Conference Call Project stage: Draft RAI ML0313205572003-05-0707 May 2003 Facsimile Transmission, Draft Request for Additional Information (RAI) to Be Discussed in an Upcoming Conference Call Project stage: Draft RAI ML0323906932003-08-27027 August 2003 Facsimile Transmission, Draft Request for Additional Information Project stage: Draft RAI ML0327405122003-10-0303 October 2003 Issuance of License Amendment 94 Changes to Technical Specifications Associated with Containment Building Penetrations Project stage: Approval ML0328016572003-10-0303 October 2003 Technical Specifications, Changes to Technical Specifications Associated with Containment Building Penetrations Project stage: Other ML0328203422003-10-0303 October 2003 Technical Specification, Changes to Technical Specifications Associated with Core Offload Decay Time Project stage: Other ML0327314212003-10-0303 October 2003 License Amendment 95 Re Changes to Technical Specifications Associated with Core Offload Decay Time Project stage: Approval 2003-03-05
[Table View] |
|
---|
Category:Memoranda
MONTHYEARML23053A0502023-02-22022 February 2023 Cover Memo and Response to C-10 Questions Regarding 3Q2022 Inspection Report ML22306A0202022-11-0202 November 2022 Cover Memo and Response to C-10 Questions Regarding 2Q2022 Inspection Report ML21242A2242021-08-26026 August 2021 C-10 Research & Education Foundation Memo Dated 8/26/21 Re Questions Regarding the 2021 Second Quarter Integrated Inspection Report (05000443/2021002) ML21062A1462021-04-21021 April 2021 Memo to File: Final Ea/Fonsi of 2012 and 2015 Decommissioning Funding Plans for Seabrook Station Unit 1 Independent Spent Fuel Storage Installation (2012 and 2015) ML19057A3832019-03-0404 March 2019 Renewal of Full-Power Operating License for Seabrook Station, Unit No. 1 ML19058A2162019-03-0404 March 2019 Update to Proposed Issuance of a Final No Significant Hazards Consideration Determination and License Amendment Regarding Which a Hearing Has Been Requested (CAC No. MF8260; EPID L-2016-LLA-0007) ML18226A2052018-09-28028 September 2018 Redacted, Submission of Alkali-Silica Reaction License Amendment Request Draft Safety Evaluation to Support Advisory Committee on Reactor Safeguards Review of Seabrook License Renewal (CAC No. MF8260; EPID L-2016-LLA-0007) ML18243A4522018-08-31031 August 2018 License Renewal Application Memorandum ML17278A1662017-10-0505 October 2017 Teleconference Meeting Summary Dated August 28, 2017 with Massachusetts Attorney General'S Office and Massachusetts Emergency Management Agency ML17254A7522017-09-0606 September 2017 Alkali-Silica Reaction Issue Technical Team Charter Revision 2 ML16088A2042016-03-28028 March 2016 Memo T Bowers from s Ruffin, Technical Assistance Requests - Review 2015 Tri-Annual Decommissioning Funding Plans for Multiple Independent Spent Fuel Storage Installations W/ Encl 2 (Template) ML16088A2052016-03-28028 March 2016 Enclosure 1 - (72.30 DFP Reviews to Be Completed 2015) - Memo T Bowers from s Ruffin, Technial Assistance Requests - Review 2015 Tri-Annual Decommissioning Funding Plans for Multiple Independent Spent Fuel Storage Installations ML16056A3342016-03-0101 March 2016 Memorandum to File Regarding Transcript for 10 CFR 2.206 Petition from C-10 Research & Education Foundation Regarding Seabrook Station, Unit 1 ML15096A1682015-07-27027 July 2015 Memorandum to File from John Lamb, DORL, NRR No Significant Hazards Consideration Analysis and Categorical Exclusion Related to Proposed Exemption ML14014A3782014-02-19019 February 2014 Alkali-Silica Reaction (ASR) Issue Technical Team Charter, Revision 1 ML13193A0742013-07-16016 July 2013 Request for Additional Information - Seabrook Station Regarding Overall Integrated Plan for Reliable Spent Fuel Pool Instrumentation (Order Number EA-12-051) (Tac No. MF0837) ML13128A5212013-06-10010 June 2013 Memo Position Paper -Assessment of Aci 318-71 as Design Basis for Category I Concrete Structures Affected by Alkalisilica Reaction at Seabrook Station. ML13154A5052013-06-0404 June 2013 Rai'S Following Ifib Analysis of NextEra Energy'S 2013 Decommissioning Funding Status Reports for Seabrook ML13099A2152013-04-18018 April 2013 Forthcoming Meeting with Nextera Energy Seabrook, LLC (Nextera) Regarding a Pre-Submittal for a Fixed Incore Detector License Amendment Request ML13066A4882013-03-21021 March 2013 Summary of Meeting Held on February 21, 2013, Between the NRC and NextEra Energy Seabrook, LLS Regarding License Renewal Application, Seabrook Station ML12242A3702012-09-0505 September 2012 Request for Deviation from the Reactor Oversight Process Action Matrix to Provide Increased Oversight of the Alkali-Silica Reaction Issue at Seabrook ML12236A3852012-08-23023 August 2012 Memo Summary of NextEra Energy Seabrook Drop in Visit and Slides, August 22, 2012 ML12222A0392012-08-0909 August 2012 8/16/2012 Cancellation Notice of Forthcoming Conference Call with NextEra Energy and Florida Power and Light Concerning Generic Letter 2004-02 and Request for NRC Staff Review of Draft Proposed Guideline for Strainer Fiber Bypass Test Proto ML12213A0612012-08-0101 August 2012 8/16/12 Forthcoming Conference Call with NextEra Energy and Florida Power & Light Concerning Generic Letter 2004-02 and Request for NRC Staff Review of Draft Proposed Guideline for Strainer Fiber Bypass Test Protocol ML12164A9012012-06-22022 June 2012 Summary of Telephone Conference Call Held on 5/24/12, Between the NRC and NextEra Energy Seabrook, LLC Concerning the Drai Pertaining to the Seabrook Station LRA ML13196A2202012-06-0606 June 2012 Memo from B. Balsam, NRR and D. Logan, NRR to J. Susco, NRR on Summary of Section 7 Consultation Activities Related to the National Marine Fisheries Service'S Final Rule to List the Atlantic Sturgeon ML12174A0152012-06-0404 June 2012 Draft Letter from J. Clifford, Region I to R. Nelson, NRR; Subject: Request for Technical Assistance, Seabrook Station Alkali-Silica Reaction ML12174A0122012-06-0404 June 2012 Draft Letter from J. Clifford, Region I to R. Nelson, NRR; Subject: Request for Technical Assistance, Seabrook Station Alkali-Silica Reaction ML12173A4632012-06-0404 June 2012 Draft Letter from D. Roberts, Region I to R. Nelson, NRR; Subject: Request for Technical Assistance, Seabrook Station Alkali-Silica Reaction ML12174A0172012-06-0404 June 2012 Draft Letter from J. Clifford, Region I to R. Nelson, NRR; Subject: Request for Technical Assistance, Seabrook Station Alkali-Silica Reaction ML12173A4622012-06-0404 June 2012 Draft Letter from D. Roberts, Region I to J. Jolicoeur, NRR; Subject: Request for Technical Assistance, Seabrook Station Alkali-Silica Reaction ML1208600492012-03-23023 March 2012 Corrected Notice of Forthcoming Meeting with NextEra Energy Seabrook, LLC (NextEra) Regarding Seabrook Station Concrete Degradation ML12054A7312012-02-16016 February 2012 DRAFT- from James Clifford to Robert Nelson Request for Technical Assistance Seabrook Station ALKALI-SILICA Reaction, Draft 3 ML12054A7292012-02-16016 February 2012 DRAFT- from James Clifford to Robert Nelson Request for Technical Assistance Seabrook Station ALKALI-SILICA Reaction, Draft 5 ML12054A7282012-02-16016 February 2012 DRAFT- from James Clifford to Robert Nelson Request for Technical Assistance Seabrook Station ALKALI-SILICA Reaction, Draft 5 ML12054A7272012-02-16016 February 2012 DRAFT- from James Clifford to Robert Nelson Request for Technical Assistance Seabrook Station ALKALI-SILICA Reaction, Draft 4 ML12054A7042012-02-16016 February 2012 DRAFT- from Darrell Roberts to John Jolicoeur Request for Technical Assistance Seabrook Station ALKALI-SILICA Reaction, Draft 2 ML12054A7112012-02-16016 February 2012 DRAFT- from James Clifford to Robert Nelson Request for Technical Assistance Seabrook Station ALKALI-SILICA Reaction, Draft 6 ML12054A7122012-02-16016 February 2012 DRAFT- from James Clifford to Robert Nelson Request for Technical Assistance Seabrook Station ALKALI-SILICA Reaction, Draft 7 (2) ML12054A7142012-02-16016 February 2012 DRAFT- from James Clifford to Robert Nelson Request for Technical Assistance Seabrook Station ALKALI-SILICA Reaction, Draft 8 Comment ML12054A7132012-02-16016 February 2012 DRAFT- from James Clifford to Robert Nelson Request for Technical Assistance Seabrook Station ALKALI-SILICA Reaction, Draft 8 2010817 ML12054A7302012-02-16016 February 2012 DRAFT- from James Clifford to Robert Nelson Request for Technical Assistance Seabrook Station ALKALI-SILICA Reaction, Draft 3. Resolved ML11354A1182011-12-22022 December 2011 12/8/2011 Summary of Meeting Between NRC Staff and the Nuclear Energy Institute to Discuss Current License Renewal Topics ML11343A4482011-12-0909 December 2011 NextEra Drop in Meeting Summary and Slides from 11-14-2011 Meeting with Region-I ML11327A0722011-11-30030 November 2011 Summary of Telephone Conference Call Held on November 22, 2011, Between the U.S. Nuclear Regulatory Commission and NextEra Energy Seabrook, LLC, Concerning the Response to the Request for Additional Information Pertaining to the Seabrook St ML11304A1662011-11-0404 November 2011 Summary of Tele Conf Call Held on 3/3/11, Between the USNRC and NextEra Energy Seabrook, Llc. Concerning Clarification of Information Pertaining to the Seabrook Station Request for Additional Information Responses ML11304A1512011-11-0404 November 2011 Summary of Tele Conf Call Held on 4/8/11 Between USNRC and NextEra Energy Seabrook, Llc. Concerning Clarification of Information Pertaining to the Seabrook Station Request for Additional Information Responses ML11304A1092011-11-0404 November 2011 Summary of Tele Conf Call Held on 5/31/11, Between the USNRC and Nextera Energy Seabrook, Llc., Concerning Clarification of Information Pertaining to the Seabrook LRA ML11277A0462011-10-26026 October 2011 Summary of Public Meetings Conducted to Discuss the Dseis Related to the Review of the Seabrook Station License Renewal Application ML11280A0452011-10-17017 October 2011 Summary of Telephone Conference Call Held on May 5, 2011, Between the U.S. Nuclear Regulatory Commission and NextEra Energy Seabrook, LLC, Concerning Clarification of Information Pertaining to the Seabrook Station LRA 2023-02-22
[Table view] Category:Request for Additional Information (RAI)
MONTHYEARML23318A0772023-11-14014 November 2023 Request for Information and Notification of Conduct of IP 71111.21.N.04, Age-Related Degradation, Reference Inspection Report 05000443/2024011 ML23173A1522023-06-22022 June 2023 Request for Additional Information NextEra Fleet Emergency Plan Amendment Request ML23011A3082023-01-11011 January 2023 Request for Additional Information Regarding Relief Request 4RA-22-001 (L-2022-LLR-0074) ML22311A5582022-11-22022 November 2022 Supplemental Information Needed for Acceptance of Requested Licensing Action Amendment Request for Cep ML22228A0552022-08-15015 August 2022 Request for Additional Information Steam Generator Tube Inspection Report Review ML22153A4152022-05-31031 May 2022 Request for Additional Information Re 120V Inverter LAR from TS Branch - Final ML22062B6642022-02-0707 February 2022 Request for Additional Information 120V Inverter LAR from the Electrical Branch ML22063A0002022-01-25025 January 2022 Requests for Additional Information from Risk Branch Regarding 120V Inverter LAR ML21245A4382021-10-0505 October 2021 Supplemental Information Needed for Acceptance of Requested Licensing Action Amendment to Revise 120-Volt AC Vital Instrument Panel Technical Specification Requirements ML21097A2512021-04-0707 April 2021 Request for Additional Information Regarding Steam Generator Tube Inspection Report Review for RFO 20 (EPID L-2020-LRO-0066) (Email) ML21054A0482021-02-23023 February 2021 Request for Additional Information Regarding Heat Flux Hot Channel Requirement Amendment Request ML20343A0942020-12-0303 December 2020 Request for Additional Information Regarding Seabrook (COVID-19) Part 73 Force-on-Force Exemption Request (L-2020-LLE-0219) ML20258A1502020-09-14014 September 2020 Request for Additional Information Related to Seabrook License Amendment Request Regarding One-Time Change to the AC Sources Operating TS ML20204A5422020-07-21021 July 2020 Request for Additional Information Related to Seabrook License Amendment Request Regarding Degraded Voltage Time Delay Setpoint ML20167A1842020-06-11011 June 2020 Request for Additional Information Related to Seabrook License Amendment Request Regarding TSTF-411 and TSTF-418 (L-2019-LLA-0237) ML20114E1592020-04-23023 April 2020 Email and Request for Additional Information Related to Seabrook License Amendment Request to Degraded Voltage Time Delay Setpoint (L-2020-LLA-0012) ML19296D9122019-10-23023 October 2019 NRR E-mail Capture - Request for Additional Information Related to Seabrook Inverter Amendment (L-2019-LLA-0216) ML18163A0352018-06-11011 June 2018 Requests for Additional Information for the Review of the Seabrook Station License Renewal Application ML18121A3992018-05-0101 May 2018 NRR E-mail Capture - Request for Additional Information Regarding ASR Amendment Request ML18113A5292018-04-18018 April 2018 NRR E-mail Capture - Draft - Request for Additional Information Regarding ASR Amendment Request ML18058A0522018-02-27027 February 2018 Enclosurequest for Additional Information (Letter: RAI Regarding Florida Power and Light/Nextera Decommissioning Funding Plan Updates for St. Lucie, Units 1 & 2; Seabrook Station; Duane Arnold Energy Center; and Point Beach, Units 1 and 2) ML18026A8792018-01-29029 January 2018 Final Requests for Additional Information for the Safety Review of the Seabrook Station License Renewal Application Docket No. 05-443 ML17332A3412017-11-29029 November 2017 Supplemental Information Needed for Acceptance of Requested Licensing Action Amendment to Delete Operator Action and Request for Exemption ML17261B2172017-10-11011 October 2017 Request for Additional Information Regarding License Amendment Request Related to Alkali-Silica Reaction (CAC No. MF8260; EPID L-2016-LLA-0007) ML17276B7572017-10-0202 October 2017 NRR E-mail Capture - Draft - Request for Additional Information Regarding ASR Amendment Request ML17214A0852017-08-0404 August 2017 Request for Additional Information Regarding License Amendment Request Related to Alkali-Silica Reaction ML17201Q1072017-07-18018 July 2017 NRR E-mail Capture - Draft - Request for Additional Information Regarding ASR Amendment Request ML17139B8352017-05-24024 May 2017 Final Request for Additional Information Regarding Seabrook License Renewal Application - Set 26 ML17150A2862017-05-0505 May 2017 NRR E-mail Capture - Draft - Request for Additional Information Regarding ASR Amendment Request ML17088A6142017-03-29029 March 2017 Request for Additional Information for the Review of the Seabrook Station License Renewal Application ML16341B9022017-03-0707 March 2017 03/07/2016 Summary of Telecon Held on Between the U.S. Nuclear Regulatory Commission and NextEra Energy Seabrook Concerning Request for Additional Information Pertaining to the Seabrook Station License Renewal Application ML16342C4672017-03-0101 March 2017 12/01/2016 Summary of Teleconference Between the U.S. Nuclear Regulatory Commission and NextEra Energy Seabrook Concerning Requests for Additional Information Pertaining to the Seabrook Station License Renewal Application ML16337A0082016-12-0101 December 2016 NRR E-mail Capture - Need for Supplement to ILRT License Amendment Seabrook Station, License Amendment Request 16-01, Request to Extend Containment Leakage Test Frequency ML16326A0372016-11-30030 November 2016 Requests for Additional Information for the Review of the Seabrook Station License Renewal Application ML16326A0092016-11-18018 November 2016 NRR E-mail Capture - Request for Additional Information Re. Nextera/Fpl LAR to Adopt TSTF-545 - CACs MF8203, MF8204, MF8208, and MF8209 ML16301A4282016-11-14014 November 2016 Requests for Additional Information for the Review of the License Renewal Application ML16319A4222016-11-10010 November 2016 NRR E-mail Capture - Need for Supplement to ILRT License Amendment ML16319A4212016-11-10010 November 2016 NRR E-mail Capture - Need for Supplement to EAL License Amendment ML16230A1062016-10-0303 October 2016 Request for Additional Information Request to Extend Containment Leakage Test Frequency ML16230A5332016-09-22022 September 2016 Request for Additional Information Amendment Request to Adopt Emergency Action Level Schemes Pursuant to NEI 99-01, Revision 6 ML16258A0222016-09-19019 September 2016 Supplemental Information Needed for Acceptance of Requested Licensing Action Alkali-Silica Reaction ML16187A2032016-07-0808 July 2016 Requests For Additional Information For The Severe Accident Mitigation Alternatives (SAMA) Review Of The Seabrook Station License Renewal Application (TAC No. Me3959)- Enclosure ML15328A1392015-12-0404 December 2015 November 23, 2015, Summary of Telephone Conference Call Held Between the U.S. Nuclear Regulatory Commission and Nextera Energy Seabrook, LLC, Concerning Requests for Additional Information Pertaining to the Seabrook Station ML15251A3332015-10-0202 October 2015 Request for Additional Information Related to the Review of the Seabrook Station, Unit 1, License Renewal Application-SET 25 ML15224A5662015-08-28028 August 2015 Request for Additional Information Related to the Review of the Seabrook Station License Renewal Application-Set 24 ML15131A3382015-06-0505 June 2015 Request for Additional Information Regarding License Amendment 14-03, Changes to Technical Specification 3.3.3.1,Radiation Monitoring for Plant Operations ML15043A2212015-02-24024 February 2015 Request for Additional Information for the Spring 2014 Steam Generator Tube Inspections ML14363A3672015-01-0909 January 2015 Request for Additional Information Regarding the License Amendment Request to Revise the Technical Specification Pressure-Temperature Limits and Request for Exemption from 10 CFR Part 50, Appendix G Minimum Tempt Requirements ML14358A0732014-12-24024 December 2014 Request for Additional Information for License Amendment Request 13-05. Fixed Incore Detector System Analysis Methodology ML14324A6372014-11-24024 November 2014 Request for Additional Information Regarding License Amendment Request to Increase Voltage Limit for Diesel Generator Load Rejection Surveillance Requirement 2023-06-22
[Table view] |
Text
March 5, 2003 MEMORANDUM TO: James W. Clifford, Chief, Section 2 Project Directorate I Division of Licensing Project Management Office of Nuclear Reactor Regulation FROM: V ictor Nerses, Sr. Project Manager, Section 2 /RA/
Project Directorate I Division of Licensing Project Management Office of Nuclear Reactor Regulation
SUBJECT:
SEABROOK STATION, UNIT NO. 1, FACSIMILE TRANSMISSION, DRAFT REQUEST FOR ADDITIONAL INFORMATION (RAI) TO BE DISCUSSED IN AN UPCOMING CONFERENCE CALL (TAC NOS.
MB6611 and MB6612)
The attached draft RAI was transmitted by facsimile on March 5, 2003, to Mr. Mike OKeefe of FPL Energy Seabrook, LLC (the licensee). This draft RAI was transmitted to facilitate the technical review being conducted by NRR and to support a conference call with the licensee to discuss the RAI. The RAI was related to the licensees submittals both dated October 11, 2002, concerning containment building penetrations and reduction of decay time for core offload. Review of the RAI would allow the licensee to determine and agree upon a schedule to respond to the RAI. This memorandum and the attachment do not convey or represent an NRC staff position regarding the licensees request.
Docket No. 50-443
Attachment:
Draft RAI
March 5, 2003 MEMORANDUM TO: James W. Clifford, Chief, Section 2 Project Directorate I Division of Licensing Project Management Office of Nuclear Reactor Regulation FROM: Victor Nerses, Sr. Project Manager, Section 2 /RA/
Project Directorate I Division of Licensing Project Management Office of Nuclear Reactor Regulation
SUBJECT:
SEABROOK STATION, UNIT NO. 1, FACSIMILE TRANSMISSION, DRAFT REQUEST FOR ADDITIONAL INFORMATION (RAI) TO BE DISCUSSED IN AN UPCOMING CONFERENCE CALL (TAC NOS.
MB6611 and MB6612)
The attached draft RAI was transmitted by facsimile on March 5, 2003, to Mr. Mike OKeefe of FPL Energy Seabrook, LLC (the licensee). This draft RAI was transmitted to facilitate the technical review being conducted by NRR and to support a conference call with the licensee to discuss the RAI. The RAI was related to the licensees submittals both dated October 11, 2002, concerning containment building penetrations and reduction of decay time for core offload. Review of the RAI would allow the licensee to determine and agree upon a schedule to respond to the RAI. This memorandum and the attachment do not convey or represent an NRC staff position regarding the licensees request.
Docket No. 50-443
Attachment:
Draft RAI DISTRIBUTION PUBLIC J. Clifford V. Nerses M. Hart PDI-2 Reading Accession Number: ML030660471 OFFICE PDI-2/PM NAME VNerses DATE 3/5/03 OFFICIAL RECORD COPY
DRAFT REQUEST FOR ADDITIONAL INFORMATION BY THE OFFICE OF NUCLEAR REACTOR REGULATION PROBABILISTIC SAFETY ASSESSMENT BRANCH CHANGES TO TS 3.9.4 CONTAINMENT BUILDING PENETRATIONS (TAC NO. MB6611)
REDUCTION OF DECAY TIME FOR CORE OFFLOAD (TAC NO. MB6612)
FACILITY OPERATING LICENSE NO. NPF-86 FPL ENERGY SEABROOK, LLC SEABROOK STATION DOCKET NO. 50-443
- 1. License Amendment Request (LAR) 02-06, Reduction of Decay Time for Core Offload, dated October 11, 2002, stated that the fuel handling accident (FHA) analyses for both the FHA in the fuel building and in the containment were revised to reflect a decay time of 80 hours9.259259e-4 days <br />0.0222 hours <br />1.322751e-4 weeks <br />3.044e-5 months <br />. The analysis for the FHA occurring in the open containment building assumed an instantaneous release directly to the outside environment. Were the preceding the only analysis inputs or assumptions that were revised to arrive at the revised dose results? Please provide the inputs and assumptions used in the revised analyses of fuel handling accidents used to support LAR 02-06 and LAR 02-07. Include assumptions on control room ventilation system operation and unfiltered in-leakage.
- 2. LAR 02-07, Changes to TS 3.9.4, Containment Building Penetrations, dated October 11, 2002, also refers to the revised FHA dose analyses as discussed in the submittal letter for LAR 02-06 as well as the current UFSAR Chapter 15.7.4 FHA dose analyses.
The current UFSAR FHA dose analyses use atmospheric dispersion factors (X/Qs) for the control room dose calculation that are based on radioactivity release due to containment leakage. Seabrook UFSAR Appendix 15B documents that these X/Qs were determined based on Equation 6 of Murphy and Campe (Ref. 1), which is applicable to a diffuse source with a point receptor. Since the equipment hatch/
proposed containment outage door opening is a much smaller release area than the entire containment building, how do these control room X/Qs remain acceptable for use for the case where the containment is open to the outside environment?
Reference
- 1. K.G. Murphy, K.M. Campe, 13th AEC Air Cleaning Conference, Nuclear Power Plant Control Room Ventilation System Design for Meeting General Design Criterion 19,"
August 1974.