MONTHYEARML0226807122002-09-25025 September 2002 Review of Steam Generator Inspection Results During 1R17 Project stage: Approval ML0234005302002-12-0606 December 2002 12/6/2002, ANO-1, Unit 1, Summary of Conference Calls on Steam Generator (SG) Inspection Results During 1R17 Project stage: Other ML0234303282002-12-0606 December 2002 12/6/2002, ANO-1, Unit 1, Enclosure 2, Summary of Conference Calls on Steam Generator (SG) Inspection Results During 1R17 Project stage: Other 2002-12-06
[Table View] |
|
---|
Category:Letter
MONTHYEARML23326A0392024-01-24024 January 2024 Issuance of Amendment No. 281 Revision to Technical Specifications to Adopt TSTF-505, Revision 2, Provide Risk-Informed Extended Completion Times - RITSTF Initiative 4b ML24017A1582024-01-17017 January 2024 Submittal of Emergency Plan Revision 50 IR 05000313/20234202024-01-10010 January 2024 Security Baseline Inspection Report 05000313/2023420 and 05000368/2023420 IR 05000313/20234022024-01-0202 January 2024 Security Baseline Inspection Report 05000313/2023402 and 05000368/2023402 ML23354A0022023-12-21021 December 2023 Request for Withholding Information from Public Disclosure ML23349A1672023-12-21021 December 2023 Request for Withholding Information from Public Disclosure ML23348A3572023-12-14014 December 2023 Application to Revise Technical Specifications to Use Online Monitoring Methodology Slides and Affidavit for Pre-Submittal Meeting ML23352A0292023-12-13013 December 2023 Entergy - 2024 Nuclear Energy Liability Evidence of Financial Protection ML23340A1592023-12-13013 December 2023 Entergy Operations, Inc. - Entergy Fleet Project Manager Assignment IR 05000313/20234052023-12-12012 December 2023 Security Baseline Inspection Report 05000313/2023405 and 05000368/2023405 ML23341A0832023-12-11011 December 2023 Material Control and Accounting Program Inspection Report 05000313/368/2023404- Cover Letter ML23305A0922023-12-0707 December 2023 Summary of Regulatory Audit Regarding License Amendment Request to Revise Technical Specifications to Adopt TSTF-505, Revision 2, Provide Risk-Informed Extended Completion Times RITSTF Initiative 4b ML23333A1362023-11-29029 November 2023 Supplement to Request for Exemption from Enhanced Weapons, Firearms Background Checks, and Security Event Notifications Implementation ML23275A2072023-11-28028 November 2023 Issuance of Amendment No. 280 Removal of Technical Specification Condition Allowing Two Reactor Coolant Pump Operation ML23325A1412023-11-21021 November 2023 Request for Exemption from Enhanced Weapons, Firearms Background Checks, and Security Event Notifications Implementation IR 05000313/20230032023-11-21021 November 2023 Revised - ANO Revised Integrated Inspection Report 05000313/2023003 and 05000368/2023003 and Independent Spent Fuel Storage Installation Inspection Report 07200013/ 2023001 ML23243B0452023-11-13013 November 2023 Request for Withholding Information from Public Disclosure ML23313A0962023-11-13013 November 2023 Integrated Inspection Report 05000313/2023003 and 05000368/2023003 and Independent Spent Fuel Storage Installation Inspection Report 07200013/2023001 ML23311A2082023-11-0909 November 2023 Reassignment of U.S. Nuclear Regulatory Commission Branch Chief in the Division of Operating Reactor Licensing for Plant Licensing Branch IV IR 05000313/20230112023-10-10010 October 2023 Commercial Grade Dedication Inspection Report 05000313/2023011 and 05000368/2023011 IR 05000313/20230052023-08-21021 August 2023 Updated Inspection Plan for Arkansas Nuclear One, Units 1 and 2 (Report 05000313/2023005 and 05000368/2023005) - Mid Cycle IR 05000313/20243012023-08-14014 August 2023 Notification of NRC Initial Operator Licensing Examination 05000313/2024301 IR 05000313/20230022023-08-11011 August 2023 Integrated Inspection Report 05000313/2023002 and 05000368/2023002 and Notice of Violation ML23209A6022023-08-0909 August 2023 Regulatory Audit Plan in Support of License Amendment Request to Revise Technical Specifications to Adopt Risk- Informed Completion Times IR 05000416/20230022023-08-0808 August 2023 Integrated Inspection Report 05000416/2023002 and Independent Spent Fuel Storage Installation Inspection Report 07200050/2023001 ML23208A2132023-08-0303 August 2023 Regulatory Audit Summary Concerning Review of License Amendment Request to Remove Technical Specification Condition Allowing Two Reactor Coolant Pump Operation ML23208A2112023-07-27027 July 2023 Entergy Operations Inc., Application to Revise Technical Specifications to Adopt TSTF-205, Revision of Channel Calibration, Channel Functional Test, and Related Definitions ML23188A1732023-07-12012 July 2023 Request for Withholding Information from Public Disclosure ML23142A2022023-06-29029 June 2023 Issuance of Amendment Nos. 279 and 332 Emergency Plan Staffing Requirements IR 05000313/20234032023-06-28028 June 2023 Security Baseline Inspection Report 05000313/2023403 and 05000368/2023403 ML23178A0892023-06-26026 June 2023 August 2023 Emergency Preparedness Program Inspection-Request for Information ML23166B0902023-06-21021 June 2023 Request for Relief ANO1 ISI 036 Regarding Volumetric Examination Requirements ML23180A1082023-06-20020 June 2023 ANO Unit 1 SAR Amendment 31, TRM, TS Bases, 10 CFR 50.59 Report, and Commitment Change Summary Report IR 05000313/20234012023-06-13013 June 2023 Cyber Security Inspection Report 05000313/2023401 and 05000368/2023401 ML23130A2972023-05-17017 May 2023 Notification of Inspection (NRC Inspection Report 05000313/2023003) and Request for Information ML23121A3012023-05-10010 May 2023 Regulatory Audit Plan in Support of License Amendment Request to Revise Technical Specifications to Adopt Risk - Informed Completion Times ML23114A3572023-05-10010 May 2023 Regulatory Audit Summary Concerning Review of Request for Alternative ANO-CISI-002 Regarding Containment Inservice Inspection Frequency ML23130A2732023-05-10010 May 2023 and Waterford 3 Steam Electric Station - Response to Regulatory Issue Summary 2023-01, Preparation and Scheduling of Operator Licensing Examinations IR 05000313/20230012023-05-0909 May 2023 Integrated Inspection Report 05000313/2023001 and 05000368/2023001 ML23118A3202023-05-0808 May 2023 Notification of Biennial Problem Identification and Resolution Inspection and Request for Information (05000313;05000368/2023010) IR 05000368/20233012023-05-0101 May 2023 NRC Examination Report 05000368/2023301 ML23117A2172023-05-0101 May 2023 Safety Evaluation for Quality Assurance Program Manual Reduction in Commitment ML23108A1362023-04-24024 April 2023 Approval of Request for Half-Nozzle Repair of Reactor Vessel Closure Head Penetration No. 46 ML23110A1122023-04-20020 April 2023 Annual Report for Entergy Quality Assurance Program Manual Changes Under 10 CFR 50.54(a)(3), 10 CFR 71.106, and 10 CFR 72.140(d). Notification of Application of Approved Appendix B to 10 CFR 72 Subpart G 2024-01-24
[Table view] |
Text
Entergy Actions for TMI Tube Sever Concerns for ANO-1 ANO-1 Scope of Potential Concern
"* ANO-1 did not install Westinghouse or B &W 1-600 mechanical rolled plugs during the 1980's. Instead, ANO-1 used either welded, ribbed or explosive plugs
"* The first rolled plug was installed in the ANO-1 OTSG's in 1992 which was Alloy-690 material.
"* Review of past outage eddy current data revealed no wear indications have ever been detected at the tubesheet face
" ANO worked with Framatome, based on the criteria presented at the Feb. 1.
2002 meeting with the NRC, to determine the susceptible plugged tube list
" List included:
- UTS plugs removed and replaced at a later date,
- UTS plugs installed could have leaked and another type of plug was placed in the tube to seal the water in the tube, 690 plugs installed was rerolled/retorqued at a later date to possibly seal in water
"* A total of 12 tubes were determined to be susceptible to possible tube swelling Entergy Planned Actions During 1R17 Outage
"* ANO has no plans to remove any plugs during 1R17
" All susceptible tubes have been evaluated and a total of 63 neighboring tubes will be plugged. 4 stabilizers will be installed in the upper span due to the industry operating experience events
"* Some tubes will be plugged as an extra "buffer zone" downstream of plugged tubes
"* Eddy Current Analysis will be performed on all tubes surrounding susceptible tubes to ensure no wear is seen on tubes prior to plugging/stabilizing Enclosure 2
a-SEntergy IRI7 Steam Generator A Status Report FRAMATOME ANP 10/17/02 3.04 AM OTSG A OTSG B Test Type Leg Probe Extent Planned Acquired Resolved Planned Acquired Resolved soblbn Col Exam -....
Non-Sicwed Tubes COLD 510ULL UTELTE 12738 13734 13734 14220 14225 1422S Non-Sleeved Tubes HOT 510UL LTEUTE 4448 A" 487 467 Tubes wt3"Slesos COLD 510UL LSELTE 54 54- 121 121 Tubes w/W.Sfe.*es COLD 101UL LSELTE 176 3 m75 351 359 Total Bobbln Exams 14812 14810 14810 15176 15172 15172 Sleeve Bobbin Exam 31"GOOSleeves HOT 400UL USELSE 54 54 121 121 W 1600 Sleeves HOT 400UL USELSE 376 275 359 353 Total Sleeve Bobbin Exams 430 JIM 430 480 480m Sleeve *Point Exam 31"Sreevs -Upper Rolls HOT 400PP USEUSR 11 11 23 23 31" Sleeves - Lomer Rolls HOT 400PP NMRLSE 11 11 23 22 8(" Sleev - Upper Rolls HOT 400PP USEUSR 156 156 125 129 80" Sleeves -Loaer Roik HOT 400PP MSRLSE 156 156 129 129 Total Sleeve *Point Exams 334 334 _ 304 304 Lower Tubesheet Crevice
- Point Examlnation Lawer Tubeshel Crevice COLD 520FP LTSLTS 683 S83 290 290 Lower Tubesheei COLD 520FP LTSLTS 24 34 Total Lower Tubesheet Crevice *Point Examinations ___17 _17 290 290 Upper Roll #Poirrt Exurramrtlon Upper Roll Trnsit ion HOT 520PP UTEUTE 12074 12072 12072 13452 13448 13448 Re-Roll Transdton HOT 520PP UTEUTE 2104 2101 2101 1244 1244 Deep Re-Roll Transition HOT 520PP UTEUTE 4 4 Total Upper Roll .*Point Examinatons _1417_ 1 14182 1_17 148_ 14.W2 14M Selected .*PointExaminartons Denied Locations 08S-UTE HOT/COLD 520PP Various 122 122 92 G2 SSA MRPC Exam HOT 520PP Vanous 11 11 1 1 Total Seleced *Point Exams = 1 6; I3 Special IlnlerststDlagnostic)
MRPC Tubes Various 6 65 4n7 4"7 W
indicalions Various 758 758 S4"4 ____
Post Re-Roll Eddy Current Bobbin HOT 51OUL I5SUTE 1188 123 123 184 76 75
.1Poinl HOT 520PP UTEURI 188 178 122 154 76 71 Plug Visual Examination 20% BAW Ribbed PlJgs HOT 9 2% WeldedPlugs CHOT _4_I_"__,.__.36 -_18 100% WesfnghaZeýRbbed 10%65 ~!rePlugs COLD ___
1__I___ I___ _______
20% Welded PILus COD7-l EMý Disinbution: Entergy R.Henry. R Jones. OCC Framartme-ANp - G.Aigelas, B Ce-1. M.Boudreaux. Fast Track, Data Managemenl