ANO Unit Two 2002 RO Examination Outline Based on NUREG-1021 Form ES-401-4 Pg 33 of 46 Rev.8 Supplement 1 K/A Category Points Point Temp Std.
Tier Group Average Total Total Dev.
K1 K2 K3 K4 K5 K6 A1 A2 A3 A4 G Tier 1 1 3 3 3 3 3 1 16 16 Plant 2 3 3 3 3 3 2 17 17 Evolutions 3 1 0 1 1 0 0 3 3 Tier Totals 7 6 7 7 6 3 36 36 6.00 1.55 Tier 2 1 3 2 2 2 2 2 2 2 2 2 2 23 23 Plant 2 2 2 2 1 2 2 1 2 2 2 2 20 20 Systems 3 1 0 1 1 1 0 0 1 1 2 0 8 8 Tier Totals 6 4 5 4 5 4 3 5 5 6 4 51 51 4.64 0.92 Tier 3 Cat1 Cat2 Cat3 Cat4 Generic 4 4 2 3 13 13 K/A/G/ Totals 13 10 12 4 5 4 10 11 5 6 20 100 100 9.09 4.93
ANO Unit 2 2002 RO Examination Outline Emergency and Abnormal Plant Evolutions - Tier 1/Group 1 E/APE # / Name / Safety Function K1 K2 K3 A1 A2 G K/A Topic(s) Imp. Points 000005 Inoperable/Stuck Control Rod / 1 Not Selected 0 015 AA1.06 - Ability to operate and/or monitor the CCWS as it 000015/17 RCP Malfunctions / 4 1 applies to a Reactor Coolant Pump Malfunction. (QID 0308) 3.1 1 CE/A13 AK1.2 - Knowledge of the operational implications and the concepts contained in the normal, abnormal and emergency CE/A13; Natural Circ. / 4 1 operating procedures associated with Natural Circulation Operations. (QID 0309) 3.2 1 024 AK3.02 - Knowledge of the reasons for the actions contained 000024 Emergency Boration / 1 1 in the EOP that apply to Emergency Boration. (QID 0310) 4.2 1 026 AA1.05 - Ability to operate and/or monitor the CCW Surge 000026 Loss of Component Cooling Water / 8 1 Tank, including level control and level alarms, and radiation monitors as they apply to the Loss of CCW. (QID 0311) 3.1 1 027 AK2.03 - Knowledge of the interrelations between the 000027 Pressurizer Pressure Control System 1 Pressurizer Pressure Control Malfunction and its associated Malfunction / 3 controllers and positioners. (QID 0312) 2.6 1 040 AK2.02 - Knowledge of the interrelations between the Steam 000040 Steam Line Rupture / 4 1 Line Rupture and its associated sensors and detectors. (QID 2.6 1 0313)
CE/E05 Excessive Steam Demand / 4 Not Selected CE/A11 AK1.2 - Knowledge of the operational implications of CE/A11 RCS Overcooling - PTS / 4 1 normal, abnormal and emergency operating procedures as they apply to RCS Overcooling. (QID 0314) 3.0 1 051 AK3.01 - Knowledge of the reasons for the loss of steam 000051 Loss of Condenser Vacuum / 4 1 dump capability upon loss of condenser vacuum. (QID 0315) 2.8 1 055 EA1.06 - Ability to operate and monitor the restoration of 000055 Station Blackout / 6 1 power with one EDG during a Station Blackout. (QID 0316) 4.1 1 057 AA2.05 - Ability to determine and interpret S/G pressure and 000057 Loss of Vital AC Elec. Inst. Bus / 6 1 level meters as they apply to a Loss of Vital AC Instrument Bus.
(QID 0431) 3.5 1 062 AA2.06 - Ability to determine and interpret the length of time 000062 Loss of Nuclear Service Water / 4 1 after the loss of Service Water System flow to a component before that component may be damaged. (QID 0432) 2.8 1 Generic 2.4.27 - Knowledge of fire in the plant procedure.
000067 Plant Fire On-site / 9 1 (QID 0319) 3.0 1 068 AK3.17 - Knowledge of the reasons for the system response 000068 Control Room Evac. / 8 1 to injection of Boric Acid into the RCS. (QID 0320) 3.7 1
ANO Unit 2 2002 RO Examination Outline Emergency and Abnormal Plant Evolutions - Tier 1/Group 1 E/APE # / Name / Safety Function K1 K2 K3 A1 A2 G K/A Topic(s) Imp. Points 069 AK1.01 - Knowledge of the operational implications of the 000069 Loss of CTMT Integrity / 5 1 effects of pressure on Containment leak rate as they apply to a Loss of Containment Integrity. (QID 0321) 2.6 1 074 EK2.03 - Knowledge of the interrelations between the AFW 000074 Inad. Core Cooling / 4 1 pump and Inadequate Core Cooling. (QID 0322) 4.0 1 BW/E03 Inadequate Subcooling Margin / 4 Not Applicable 0 076 AA2.02 - Ability to determine and interpret the corrective 000076 High Reactor Coolant Activity / 9 1 actions required for high fission product activity in the RCS as they apply to high Reactor Coolant Activity. (QID 0323) 2.8 1 BW/A02&A03 Loss of NNI-X/Y / 7 Not Applicable 0 K/A Category Totals: 3 3 3 3 3 1 Group Point Total = 16 16 16
ANO Unit 2 2002 RO Examination Outline Emergency and Abnormal Plant Evolutions - Tier 1/Group 2 E/APE # / Name / Safety Function K1 K2 K3 A1 A2 G K/A Topic(s) Imp. Points 000001 Continuous Rod Withdrawal / 1 Not Selected 0 003 AK1.10 - Knowledge of the operational implications of the 000003 Dropped Control Rod / 1 1 definitions of core quadrant tilt as they apply to Dropped Control Rod. (QID 0324) 2.6 1 007 EK1.06 - Knowledge of the operational implications of the 000007 Reactor Trip - Stabilization / 1 1 relationship of emergency feedwater flow to S/G and decay heat removal following reactor trip. (QID 0325) 3.7 1 CE/E02 Reactor Trip Recovery / 1 Not Selected BW/A01 Plant Runback / 1 Not Applicable 0 BW/A04 Turbine Trip / 4 Not Applicable 0 008 AK2.02 - Knowledge of the interrelations between the 000008 Pressurizer Vapor Space Accident / 3 1 Pressurizer Vapor Space Accident and the sensors & detectors.
(QID 0326) 2.7 1 009 EA1.16 - Ability to operate and monitor Subcooling margin 000009 Small Break LOCA / 3 1 monitors as they apply to a Small Break LOCA. (QID 0327) 4.2 1 011 EK2.02 - Knowledge of the interrelations between the pumps 000011 Large Break LOCA / 3 1 and Large Break LOCA. (QID 0328) 2.6 1 W/E04 LOCA Outside Containment / 3 Not applicable. 0 BW/E08; W/E03 LOCA Cooldown/Depress. / 4 Not applicable. 0 W/E11 Loss of Emergency Coolant Recirc. / 4 Not applicable. 0 W/E01 & E02 Rediagnosis & SI Termination / 3 Not applicable. 0 022 AA1.08 - Ability to operate and/or monitor VCT level as it 000022 Loss of Reactor Coolant Makeup / 2 1 applies to the Loss of Reactor Coolant Makeup. (QID 0329) 3.4 1 025 AA2.04 - Ability to determine and interpret the location and 000025 Loss of RHR System / 4 1 isolability of leaks as they apply to the Loss of Residual Heat Removal System. (QID 0433) 3.3 1 029 EK3.11 - Knowledge of the reasons for initiating emergency 000029 Anticipated Transient w/o Scram / 1 1 boration as they apply to ATWS. (QID 0331) 4.2 1 000032 Loss of Source Range NI / 7 Not applicable. 0 000033 Loss of Intermediate Range NI / 7 Not applicable. 0 Generic 2.4.11 - Knowledge of Steam Generator Tube Leak 000037 Steam Generator Tube Leak / 3 1 abnormal condition procedures. (QID 0332) 3.4 1 038 EA2.08 - Ability to determine viable alternatives for placing 000038 Steam Generator Tube Rupture / 3 1 plant in safe condition when condenser is not available when SGTR present. (QID 00434) 3.8 1 054 AK3.04 - Knowledge of the reasons for the following actions 000054 Loss of Main Feedwater / 4 1 contained in the EOPs for Loss of MFW. (QID 0334) 4.4 1
ANO Unit 2 2002 RO Examination Outline Emergency and Abnormal Plant Evolutions - Tier 1/Group 2 E/APE # / Name / Safety Function K1 K2 K3 A1 A2 G K/A Topic(s) Imp. Points CE/E06 EA1.2 - Ability to operate and/or monitor Operating CE/EO6 Loss of Main Feedwater / 4 1 behavior characteristics of the facility as they apply to Loss of Feedwater. (QID 0444) 3.4 1 BW/E04; W/E05 Inadequate Heat Transfer - Loss Not applicable.
of Secondary Heat Sink / 4 0 058 AK3.01 - Knowledge of the reasons for use of DC control 000058 Loss of DC Power / 6 1 power by D/Gs as they apply to the Loss of DC Power.(QID 0336) 3.4 1 059 AA2.04 - Ability to determine and interpret the valve lineup for 000059 Accidental Liquid Radwaste Rel. / 9 1 a release of radioactive fluid as they apply to the Accidental Liquid Radwaste Release. (QID 0435) 3.2 1 Generic 2.4.10 - Knowledge of annunciator response procedures 000060 Accidental Gaseous Radwaste Rel. / 9 1 associated with an accidental gaseous radwaste release. (QID 0338) 3.0 1 061 AK2.01 - Knowledge of the interrelations between the Area 000061 ARM System Alarms / 7 1 Radiation Monitoring (ARM) System Alarms and the detectors at each ARM location. (QID 0339) 2.5 1 W/E16 High Containment Radiation / 9 Not applicable. 0 CE/E09 EK1.2 - Knowledge of the operational implications of CE/E09 Functional Recovery 1 normal, abnormal and emergency procedures associated with Functional Recovery. (QID 0448) 3.2 1 K/A Category Totals: 3 3 3 3 3 2 Group Point Total = 17 17 17
ANO Unit 2 2002 RO Examination Outline Emergency and Abnormal Plant Evolutions - Tier 1/Group 3 E/APE # / Name / Safety Function K1 K2 K3 A1 A2 G K/A Topic(s) Imp. Points 028 AA1.07 - Ability to operate and/or monitor charging pumps in 000028 Pressurizer Level Malfunction / 2 1 maintenance of PZR level (including manual backup) as applied to the Pressurizer Level Control Malfunctions. (QID 0341) 3.3 1 000036 Fuel Handling Accident / 8 Not Selected 0 056 AK1.01 - Knowledge of the operational implications of the 000056 Loss of Off-site Power / 6 1 principle of cooling by natural convection. (QID 0342) 3.7 1 065 AK3.04 - Knowledge of the reasons for cross-over to backup 000065 Loss of Instrument Air / 8 1 air supplies as they apply to the Loss of Instrument Air. (QID 0343) 3.0 1 BW/E13&E14 EOP Rules and Enclosures Not applicable. 0 BW/A05 Emergency Diesel Actuation / 6 Not applicable. 0 BW/A07 Flooding / 8 Not applicable. 0 CE/A16 Excess RCS Leakage / 2 Not Selected 0 W/E13 Steam Generator Over-pressure / 4 Not applicable. 0 W/E15 Containment Flooding / 5 Not applicable. 0 K/A Category Totals: 1 0 1 1 0 0 Group Point Total = 3 3 3
PWR RO Examination Outline ANO Unit 2 2002 RO Examination Outline Plant Systems - Tier 2/Group 1 System # / Name K1 K2 K3 K4 K5 K6 A1 A2 A3 A4 G K/A Topic Imp. Points 001 Control Rod Drive 001 A4.03 - Ability to manually operate and/or monitor in the control 1 4.0 1 room CRDS mode control. (QID 0344) 001 Control Rod Drive 001 K4.20 - Knowledge of CRDS design feature(s) and/or interlocks 1 which provide the permissives and interlocks associated with 3.2 1 increase from zero power. (QID 0345) 003 Reactor Coolant Pump 003 K6.04 - Knowledge of the effect of a loss or malfunction of 1 containment isolation valves will have on RCP operation. 2.8 1 (QID 0346) 003 Reactor Coolant Pump 003 K1.13 - Knowledge of the physical connections and/or cause-1 effect relationships between the RCPs and RCP bearing lift oil 2.5 1 pumps. (QID 0347) 004 Chem and Volume Control 004 A3.06 - Ability to monitor automatic operation of the CVCS 1 3.9 1 including effects of Tave and Tref. (QID 0348) 004 Chem and Volume Control 004 K4.13 - Knowledge of CVCS design feature(s) and/or interlocks 1 which provide for interlock between letdown isolation valve and flow 3.1 1 control valve. (QID 0349) 013 Eng Safety Features Act 013 A4.01 - Ability to manually operate and/or monitor in the control 1 4.5 1 room ESFAS initiated equipment which fails to actuate. (QID 0350) 013 Eng Safety Features Act 013 K3.03 - Knowledge of the effect that a loss or malfunction of the 1 4.3 1 ESFAS will have on the Containment. (QID 0351) 015 Nuclear Instrumentation Generic 2.2.12 - Knowledge of surveillance procedures. (QID 1 3.0 1 0352) 015 Nuclear Instrumentation 015 K2.01 - Knowledge of bus power supplies to the NIS channels, 1 3.3 1 components, and interconnections. (QID 0353) 017 In-core Temp Monitor 017 A1.01 - Ability to predict and/or monitor changes in parameters 1 (to prevent exceeding design limits) associated with operating the 3.7 1 ITM System controls including Core Exit Temperatures. (QID 0354) 017 In-core Temp Monitor 017 K6.01 - Knowledge of the effect of a loss or malfunction of the 1 2.7 1 ITM System sensors and detectors. (QID 0355) 022 Containment Cooling 022 K1.01 - Knowledge of the physical connections and/or cause-1 effect relationships between the Containment Cooling System and 3.5 1 Service Water System/Cooling System. (QID 0356) 022 Containment Cooling 022 K3.02 - Knowledge of the effect that a loss or malfunction of the 1 Containment Cooling System will have on Containment 3.0 1 Instrumentation readings. (QID 0357) 025 Ice Condenser Not applicable. 0
Plant Systems - Tier 2/Group 1 System # / Name K1 K2 K3 K4 K5 K6 A1 A2 A3 A4 G K/A Topic Imp. Points 056 Condensate 056 A2.04 - Ability to (a) predict the impact of Loss of Condensate Pumps on the Condensate System; and (b) based on those 1 2.6 1 predictions, use procedures to correct, control, or mitigate the consequences of those malfunctions or operations. (QID 0358) 059 Main Feedwater 059 K1.05 - Knowledge of the physical connections and/or cause 1 effect relationships between the MFW system and the RCS. (QID 3.1 1 0359) 061 Aux/Emerg Feedwater 061 A1.05 - Ability to predict and/or monitor changes in parameters (to prevent exceeding design limits) associated with operating the 1 3.6 1 AFW/EFW controls including AFW/EFW flow/motor amps.
(QID 0360) 061 Aux/Emerg Feedwater 061 K2.01 - Knowledge of bus power supplies to the AFW/EFW 1 3.2 1 System MOVs. (QID 0361) 068 Liquid Radwaste 068 A3.02 - Ability to monitor automatic operation of the Liquid 1 3.6 1 Radwaste System including automatic isolation. (QID 0362) 068 Liquid Radwaste Generic 2.3.1 - Knowledge of 10CFR20 and related facility radiation 1 2.6 1 controls. (QID 449) 071 Waste Gas Disposal 071 K5.04 - Knowledge of the operational implications of the 1 relationship of hydrogen/oxygen concentration to flammability as they 2.5 1 apply to the Waste Gas Disposal System. (QID 0364) 072 Area Radiation Monitoring 072 A2.02 - Ability to (a) predict the impacts of a detector failure on the Area Radiation Monitoring System and (b) based on those 1 2.8 1 predictions, use procedures to correct, control, or mitigate the consequences of those malfunctions or operations. (QID 0365) 072 Area Radiation Monitoring 072 K5.01 - Knowledge of the operational implications of radiation 1 2.7 1 theory, including sources, types, units and effects. (QID 0366)
K/A Category Totals: 3 2 2 2 2 2 2 2 2 2 2 Group Point Total = 23 23 23
ANO Unit 2 2002 RO Examination Outline Plant Systems - Tier 2/Group 2 System # / Name K1 K2 K3 K4 K5 K6 A1 A2 A3 A4 G K/A Topic Imp. Points Generic 2.1.32 - Ability to explain and apply all system limits 002 Reactor Coolant 1 3.4 1 and precautions. (QID 0367) 006 A4.03 - Ability to operate and/or monitor in the control 006 Emergency Core Cooling 1 room transfer from boron storage tank to boron injection tank. 3.5 1 (QID 0368) 010 K2.02 - Knowledge of bus power supplies to the controller 010 Pressurizer Press Control 1 2.5 1 for PZR spray valve. (QID 0369) 010 K6.03 - Knowledge of the effect of a loss or malfunction of 010 Pressurizer Press Control 1 the PZR sprays and heaters will have on the PZR Pressure 3.2 1 Control System. (QID 0370) 011 K2.02 - Knowledge of bus power supplies to the PZR 011 Pressurizer Level Control 1 3.1 1 heaters. (QID 0371) 012 K6.01 - Knowledge of the effect of a loss or malfunction of 012 Reactor Protection 1 bistables and bistable test equipment will have on the RPS. 2.8 1 (QID 0372) 014 K5.01 - Knowledge of the operational implications of the 014 Rod Position Indication 1 reasons for differences between Rod Position Indication 2.7 1 System and step counter. (QID 0373) 016 Non-nuclear Instrument Not Applicable 0 026 K1.01 - Knowledge of the physical connections and/or 026 Containment Spray 1 cause-effect relationships between the Containment Spray 4.2 1 System and the ECCS. (QID 0374) 029 K1.03 - Knowledge of the physical connections and/or 029 Containment Purge 1 cause-effect relationships between the Containment Purge 3.6 1 System and Engineered Safeguards System. (QID 0219) 033 A2.03 - Ability to (a) predict the impacts of abnormal SFP water level or loss of water level on the Spent Fuel Pool 033 Spent Fuel Pool Cooling 1 Cooling System and (b) based on those predictions, use 3.1 1 procedures to correct, control, or mitigate the consequences of those malfunctions or operations. (QID 0300)
Generic 2.1.12 - Ability to apply technical specifications for the 035 Steam Generator 1 2.9 1 Steam Generator System. (QID 0377) 039 A3.02 - Ability to monitor automatic operation of the 039 Main and Reheat Steam 1 Main/Reheat Steam System, including isolation of the M/R 3.1 1 Steam System. (QID 0378)
ANO Unit 2 2002 RO Examination Outline Plant Systems - Tier 2/Group 2 System # / Name K1 K2 K3 K4 K5 K6 A1 A2 A3 A4 G K/A Topic Imp. Points 055 K3.01 - Knowledge of the effect that a loss or malfunction 055 Condenser Air Removal 1 of the Condenser Air Removal System will have on the main 2.5 1 condenser. (QID 0379) 062 A1.03 - Ability to predict and/or monitor changes in parameters (to prevent exceeding design limits) associated 062 AC Electrical Distribution 1 with operating the AC Distribution System controls including the 2.5 1 effect on instrumentation and controls of switching power supplies. (QID 0442) 063 K3.01 - Knowledge of the effect that a loss or malfunction 063 DC Electrical Distribution 1 3.7 1 of the DC electrical system will have on the EDG. (QID 0381) 064 A3.07 - Ability to monitor automatic operation of the EDG 064 Emerg Diesel Generator 1 3.6 1 system, including load sequencing. (QID 0382) 073 K5.01 - Knowledge of the operational implications of radiation theory, including sources, types, units and effects as 073 Process Radiation Monitoring 1 2.5 1 they apply to the Process Radiation Monitoring System.
(QID 0383) 075 K4.01 - Knowledge of Circulating Water System design 075 Circulating Water 1 feature(s) and interlock(s) which provide for heat sink. 2.5 1 (QID 0384) 079 K4.01 - Deselected - Use Plant Specific Priorities QID 079 Station Air 1 3.1 1 0385 in Tier 2 Group 3.
086 A4.01 - Ability to manually operate and/or monitor in the 086 Fire Protection 1 3.3 1 control room the fire detection panels. (QID 0386)
K/A Category Totals: 2 2 2 1 2 2 1 2 2 2 2 Group Point Total = 20 20 20
ANO Unit 2 2002 RO Examination Outline Plant Systems - Tier 2/Group 3 System # / Name K1 K2 K3 K4 K5 K6 A1 A2 A3 A4 G K/A Topic Imp. Points 005 K5.02 - Knowledge of the operational implications of the 005 Residual Heat Removal 1 need for adequate subcooling as they apply to the Residual 3.4 1 Heat Removal System. (QID 0387) 007 K1.03 - Knowledge of the physical connections and/or 007 Pressurizer Relief/Quench Tank 1 cause-effect relationships between the Quench Tank System 3.0 1 and the RCS. (QID 0388) 008 Component Cooling Water Not selected 0 027 Containment Iodine Removal Not selected 0 028 A4.01 - Ability to manually operate and/or monitor in the 028 Hydrogen Recomb/ Purge Control 1 control room the Hydrogen Recombiner and Purge Control 4.0 1 System controls. (QID 0389) 034 A4.02 - Ability to manually operate and/or monitor neutron 034 Fuel Handling Equipment 1 levels in the control room during refueling operations (QID 3.5 1 0390) 041 K3.01 - Knowledge of the effect that a loss or malfunction 041 Stm Dump/Turb Bypass Control 1 3.2 1 of the Steam Dump System will have on SGs. (QID 0391) 045 A2.08 - Ability to (a) predict the impacts of steam dumps not cycling properly at low load, or stick open at higher load (isolate and use atmospheric reliefs when necessary) on MTG 045 Main Turbine Generator 1 2.8 1 system and (b) based on those predictions, use procedures to correct, control, or mitigate the consequences of those malfunctions or operations. (QID 0392) 076 Service Water Not selected 0 078 A3.01 - Ability to monitor automatic operation of the 078 Instrument Air 1 3.1 1 Instrument Air System including air pressure. (QID 0393) 103 K4.06 -Knowledge of containment system design 103 Containment 1 feature(s) and/or interlock(s) which provide for the 3.1 1 containment isolation system. (QID 0394) 0 K/A Category Totals: 1 0 1 1 1 0 0 1 1 2 0 Group Point Total = 8 8
ANO Unit 2 2002 RO Examination Outline Plant Systems - Tier 2/Group 3 Plant-Specific Priorities System/Topic Recommended Replacement for Reason Points 064 A2.09 Ability to predict the impact of a malfunction of the EDG System during synchronizing an EDG with other electric power supplies and based on those predictions, use procedures to correct, control or mitigate the consequences of the malfunction or operation.
Condition reports ANO-2-2001 0158 and 0491 document a condition 064 Emergency Diesel Generators 079 Station Air in Tier 2 Group 2 whereby the number 1 EDG was declared inoperable during an 1 attempt to tie the diesel to offsite power during a surveillance. (Refer to the references in the question) This is a much higher plant priority than the randomly selected Station Air K&A 079 K4.01 (Tier 2 Group2) especially since the Station Air System crossconnect to the Instrument Air system is a manual valve. QID 0385 Plant-Specific Priority Total: (limit 10) 1 1 8
ES-401 Generic Knowledge and Abilities Outline (Tier 3)
Based on NUREG 1021 Rev. 8 Supplement 1 Form ES-401-5 Facility: ANO - Unit 2 Date of Exam: 02/08/02 Exam Level: RO Category K/A # Topic Imp. Points 2.1.17 Ability to make accurate, clear and concise verbal reports. (QID 0447) 3.5 1 2.1.22 Ability to determine Mode of Operations. (QID 0421) 2.8 1 2.1.12 Ability to apply technical specifications for a system. (QID 0397) 2.9 1 Conduct of 2.1.32 Ability to explain and apply all system limits and precautions. (QID 0398) 3.4 1 Operations 2.1.
2.1.
Total 4 2.2.27 Knowledge of the refueling process (QID 0399) 2.6 1 Ability to manipulate the console controls as required to operate the facility between shutdown and 2.2.2 designated power levels. (QID 0400) 4.0 1 Equipment 2.2.33 Knowledge of control rod programming. (QID 0401) 2.5 1 Control 2.2.11 Knowledge of the process for controlling temporary changes. (QID 0037) 2.5 1 2.2.
2.2.
Total 4 Ability to perform procedures to reduce excessive levels of radiation and guard against personnel 2.3.10 exposure. (QID 0298) 2.9 1 2.3.2 Knowledge of facility ALARA program. (QID 0439) 2.5 1 Radiation 2.3.
Control 2.3.
2.3.
2.3.
Total 2 2.4.31 Knowledge of annunciator alarms and indications, and use of the response instructions. (QID 0405) 3.3 1 2.4.19 Knowledge of EOP layout, symbols, and icons. (QID 0406) 2.8 1 Emergency 2.4.15 Knowledge of communications procedures associated with EOP Implementation. (QID 0407) 3.0 1 Procedures 2.4.
/
2.4.
Plan 2.4.
Total 3 Tier 3 Point Total (RO) 13 13