MONTHYEARLR-N23-0079, Special Report 23-02-00 Pursuant to the Requirements of Salem Unit 1 Technical Specification 3.3.3.7, Action 10, for the Unit 1 Main Steam Line Rad Monitor Inoperable for Greater than Seven Days2023-12-0707 December 2023 Special Report 23-02-00 Pursuant to the Requirements of Salem Unit 1 Technical Specification 3.3.3.7, Action 10, for the Unit 1 Main Steam Line Rad Monitor Inoperable for Greater than Seven Days LR-N23-0077, Loss of Coolant Accident Peak Cladding Temperature Margin Tracking - Annual Report 2023 & 30 Day Report for Salem Unit 1 Upflow Conversion2023-11-29029 November 2023 Loss of Coolant Accident Peak Cladding Temperature Margin Tracking - Annual Report 2023 & 30 Day Report for Salem Unit 1 Upflow Conversion LR-N23-0072, Core Operating Limits Report Cycle 302023-11-0101 November 2023 Core Operating Limits Report Cycle 30 LR-N23-0045, and Peach Bottom Atomic Power Station, Units 2 and 3 - Notice of Proposed Amendment to Decommissioning Trust Agreement2023-09-0808 September 2023 and Peach Bottom Atomic Power Station, Units 2 and 3 - Notice of Proposed Amendment to Decommissioning Trust Agreement LR-N23-0055, Special Report 272/23-01-00, Pursuant to the Requirements of Technical Specification 3.3.3.1, Action 23, for the Vent Noble Gas Rad Monitor Inoperable for Greater than Seven Days2023-08-0303 August 2023 Special Report 272/23-01-00, Pursuant to the Requirements of Technical Specification 3.3.3.1, Action 23, for the Vent Noble Gas Rad Monitor Inoperable for Greater than Seven Days LR-N23-0054, In-Service Inspection Activities2023-07-26026 July 2023 In-Service Inspection Activities LR-N23-0046, Emergency Plan Document Revisions Implemented June 28, 20232023-07-10010 July 2023 Emergency Plan Document Revisions Implemented June 28, 2023 LR-N23-0005, License Amendment Request to Amend Technical Specifications (TS) 6.8.4.f for Permanent Extension of Type a and Type C Leak Rate Test Frequencies2023-06-23023 June 2023 License Amendment Request to Amend Technical Specifications (TS) 6.8.4.f for Permanent Extension of Type a and Type C Leak Rate Test Frequencies LR-N23-0035, 2022 Annual Radioactive Effluent Release Report (ARERR)2023-04-27027 April 2023 2022 Annual Radioactive Effluent Release Report (ARERR) LR-N23-0034, 2022 Annual Radiological Environmental Operating Report (AREOR) - Salem Nuclear Generating Station, Unit Nos. 1 and 2 and Hope Creek Generating Station2023-04-27027 April 2023 2022 Annual Radiological Environmental Operating Report (AREOR) - Salem Nuclear Generating Station, Unit Nos. 1 and 2 and Hope Creek Generating Station LR-N23-0033, Core Operating Limits Report Cycle 272023-04-26026 April 2023 Core Operating Limits Report Cycle 27 LR-N23-0010, License Amendment Request Revision of Technical Specification (TS) to Delete TS Section 5.5 - Meteorological Tower Location2023-04-21021 April 2023 License Amendment Request Revision of Technical Specification (TS) to Delete TS Section 5.5 - Meteorological Tower Location LR-N23-0006, Report on Status of Decommissioning Funding for Reactors and Independent Spent Fuel Storage Installations2023-03-24024 March 2023 Report on Status of Decommissioning Funding for Reactors and Independent Spent Fuel Storage Installations LR-N23-0019, and Salem Generating Station, Units 1 and 2 - Guarantees of Payment of Deferred Premiums2023-03-21021 March 2023 and Salem Generating Station, Units 1 and 2 - Guarantees of Payment of Deferred Premiums LR-N23-0016, and Salem Generating Station, Units 1 and 2 - Report of Changes, Tests, and Experiments2023-02-28028 February 2023 and Salem Generating Station, Units 1 and 2 - Report of Changes, Tests, and Experiments LR-N23-0012, Annual Property Insurance Status Report2023-02-24024 February 2023 Annual Property Insurance Status Report LR-N23-0014, Stations Submittal of 2022 Annual Report of Fitness for Duty Performance Data Per 10 CFR 26.203(e) and 10 CFR 26.7172023-02-23023 February 2023 Stations Submittal of 2022 Annual Report of Fitness for Duty Performance Data Per 10 CFR 26.203(e) and 10 CFR 26.717 LR-N23-0003, Response to Requests for Additional Information Salem Unit 2 Relief Request S2-I4R-2112023-02-0101 February 2023 Response to Requests for Additional Information Salem Unit 2 Relief Request S2-I4R-211 LR-N22-0096, and Salem Generating Station, Units 1 and 2 - Request for Threshold Determination2023-01-0505 January 2023 and Salem Generating Station, Units 1 and 2 - Request for Threshold Determination LR-N22-0095, Loss of Coolant Accident Peak Cladding Temperature Margin Tracking - Annual Report 20222022-12-20020 December 2022 Loss of Coolant Accident Peak Cladding Temperature Margin Tracking - Annual Report 2022 LR-N22-0094, Emergency Plan Document Revisions Implemented November 21, 20222022-12-14014 December 2022 Emergency Plan Document Revisions Implemented November 21, 2022 LR-N22-0092, Response to Final Iolb Request for Additional Information for Salem LAR to Revise TS to Extend Allowed Outage Time for Inoperable EDG2022-12-0909 December 2022 Response to Final Iolb Request for Additional Information for Salem LAR to Revise TS to Extend Allowed Outage Time for Inoperable EDG LR-N22-0091, Independent Spent Fuel Storage Installation, Report of 10 CFR 72.48 Changes, Tests, and Experiments2022-12-0202 December 2022 Independent Spent Fuel Storage Installation, Report of 10 CFR 72.48 Changes, Tests, and Experiments LR-N22-0084, Response to Final Request for Additional Information for Salem LAR to Revise TS to Extend Allowed Outage Time for Inoperable EDG (EPID L- 2022-LLA-0095)2022-11-17017 November 2022 Response to Final Request for Additional Information for Salem LAR to Revise TS to Extend Allowed Outage Time for Inoperable EDG (EPID L- 2022-LLA-0095) LR-N22-0090, Supplement to Submittal of Salem Generating Station Updated FSAR, Revision 33, 10 CFR 71.106 Review Results and 10 CFR 54.37(b) Review Results for Salem2022-11-10010 November 2022 Supplement to Submittal of Salem Generating Station Updated FSAR, Revision 33, 10 CFR 71.106 Review Results and 10 CFR 54.37(b) Review Results for Salem LR-N22-0065, Submittal of Relief Request Associated with the Fourth Inservice Inspection (ISI) Interval Limited Examinations2022-09-27027 September 2022 Submittal of Relief Request Associated with the Fourth Inservice Inspection (ISI) Interval Limited Examinations LR-N22-0074, Emergency Plan Evacuation Time Estimate2022-09-15015 September 2022 Emergency Plan Evacuation Time Estimate LR-N22-0066, License Amendment Request (LAR) to Relocate Technical Specifications (TS) Requirements for Reactor Head Vents to the Technical Requirements Manual (TRM)2022-08-31031 August 2022 License Amendment Request (LAR) to Relocate Technical Specifications (TS) Requirements for Reactor Head Vents to the Technical Requirements Manual (TRM) LR-N22-0063, Spent Fuel Cask Registration2022-08-10010 August 2022 Spent Fuel Cask Registration LR-N22-0068, In-Service Inspection Activities - 90-Day Report2022-08-10010 August 2022 In-Service Inspection Activities - 90-Day Report LR-N22-0012, License Amendment Request to Amend the Technical Specifications to Revise and Relocate the Reactor Coolant System Pressure and Temperature Limits and Pressurizer Overpressure Protection System Limits to a Pressure and Temperature2022-08-0707 August 2022 License Amendment Request to Amend the Technical Specifications to Revise and Relocate the Reactor Coolant System Pressure and Temperature Limits and Pressurizer Overpressure Protection System Limits to a Pressure and Temperature LR-N22-0062, Spent Fuel Cask Registration2022-07-21021 July 2022 Spent Fuel Cask Registration LR-N22-0006, License Amendment Request (LAR) to Amend Salem Unit 1 and Unit 2 Technical Specifications (TS) to Extend the Allowed Outage Time for an Inoperable Emergency Diesel Generator from 72 Hours to 14 Days2022-06-29029 June 2022 License Amendment Request (LAR) to Amend Salem Unit 1 and Unit 2 Technical Specifications (TS) to Extend the Allowed Outage Time for an Inoperable Emergency Diesel Generator from 72 Hours to 14 Days LR-N22-0051, License Amendment Request to Relocate Technical Specification Facility/Unit Staff Qualification Requirements to Quality Assurance Topical Report2022-06-22022 June 2022 License Amendment Request to Relocate Technical Specification Facility/Unit Staff Qualification Requirements to Quality Assurance Topical Report LR-N22-0044, Emergency Plan Document Revisions Implemented November, 20212022-05-19019 May 2022 Emergency Plan Document Revisions Implemented November, 2021 LR-N22-0043, Core Operating Limits Report - Cycle 292022-05-0909 May 2022 Core Operating Limits Report - Cycle 29 LR-N22-0041, 2021 Annual Radioactive Effluent Release Report (Rerr)2022-04-28028 April 2022 2021 Annual Radioactive Effluent Release Report (Rerr) LR-N22-0040, 2021 Annual Radiological Environmental Operating Report2022-04-28028 April 2022 2021 Annual Radiological Environmental Operating Report LR-N22-0039, Emergency Plan Document Revisions Implemented March 24, 20222022-04-21021 April 2022 Emergency Plan Document Revisions Implemented March 24, 2022 LR-N21-0052, Request for Relief from ASME Code Defect Removal for Service Water Buried Piping2022-04-0707 April 2022 Request for Relief from ASME Code Defect Removal for Service Water Buried Piping LR-N22-0023, Guarantees of Payment of Deferred Premiums2022-03-21021 March 2022 Guarantees of Payment of Deferred Premiums LR-N22-0022, Response to Request for Additional Information Relief Request S1-14R-210, Alternative Examination of Welds2022-03-21021 March 2022 Response to Request for Additional Information Relief Request S1-14R-210, Alternative Examination of Welds LR-N22-0017, Submittal of 2021 Annual Report of Fitness for Duty (FFD) Performance Data2022-02-25025 February 2022 Submittal of 2021 Annual Report of Fitness for Duty (FFD) Performance Data LR-N22-0016, Radiological Survey of Site Property to Be Used for Offshore Wind Port Facility2022-02-24024 February 2022 Radiological Survey of Site Property to Be Used for Offshore Wind Port Facility LR-N22-0013, In-Service Inspection Activities - 90-Day Report2022-02-10010 February 2022 In-Service Inspection Activities - 90-Day Report LR-N22-0007, Request for Exemption from Specific Requirements of 10 CFR Part 26, Fitness for Duty Programs2022-01-0505 January 2022 Request for Exemption from Specific Requirements of 10 CFR Part 26, Fitness for Duty Programs LR-N21-0061, Annual Report of Specific Activity Analysis - TS 6.9.1.5c2021-12-0909 December 2021 Annual Report of Specific Activity Analysis - TS 6.9.1.5c LR-N21-0083, Loss of Coolant Accident Peak Cladding Temperature Margin Tracking - Annual Report 2021 & 30 Day Report for Salem Unit 2 Upflow Conversion2021-11-24024 November 2021 Loss of Coolant Accident Peak Cladding Temperature Margin Tracking - Annual Report 2021 & 30 Day Report for Salem Unit 2 Upflow Conversion LR-N21-0078, Hope and Creek Generating Station, Supplement to License Amendment Request to Revise Technical Specifications (TS) to Delete Definitions Found in 10 CFR Part 20 and Delete Figures of the Site and Surrounding Areas from TS2021-11-18018 November 2021 Hope and Creek Generating Station, Supplement to License Amendment Request to Revise Technical Specifications (TS) to Delete Definitions Found in 10 CFR Part 20 and Delete Figures of the Site and Surrounding Areas from TS LR-N21-0066, Submittal of Relief Request Associated with the Fourth Inservice Inspection (ISI) Interval Limited Examinations2021-11-10010 November 2021 Submittal of Relief Request Associated with the Fourth Inservice Inspection (ISI) Interval Limited Examinations 2023-09-08
[Table view] |
Text
PSEG Nuclear LLC P.O. Box 236, Hancocks Bridge, New Jersey 08038-0236 0 PSEG Nuclear LLC Technical Specification 6.9.1.5 Technical Specification 4.4.6.5.a AUG 2001 LR-N07-0183 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 Salem Nuclear Generating Station Unit 2 Facility Operating License No. DPR-75 NRC Docket No. 50-311
Subject:
Response to Request for Additional Information Regarding Steam Generator Tube Inspections Conducted During the Fall 2006 Refueling Outage Salem Nuclear Generating Station, Unit No. 2 Docket No. 50-311
References:
(1) PSEG Letter LR-N06-0434, "Steam Generator Tube Plugging Report," dated November 6, 2006.
(2) PSEG Letter LR-N07-0045, "2006 Steam Generator Tube ISI Summary Report," dated March 1, 2007.
.(3) NRC letter to Mr. William Levis "Request for Additional Information Regarding Steam Generator Tube Inspections Conducted During the Fall 2006 Refueling Outage Salem Nuclear Generating Station, Unit No. 2," dated July 10, 2007.
PSEG Nuclear LLC (PSEG) hereby transmits its response to the Nuclear Regulatory commission (NRC) request for additional information as documented in Reference 3. to this letter contains the NRC's questions in bolded text followed by PSEG response. The response provided is consistent with the discussion held between PSEG and NRC personnel in a teleconference held on July 3, 2007.
9 eV4L 95-2168 REV. 7/99
,AUG6 0 3 2001 Document Control Desk Page 2 LR-N07-0183 If there are any questions regarding this letter, please contact E. H. Villar at (856) 339 - 5456.
Sincerely, Robert C. Braun Site Vice President - Salem Attachments (1) cc: Mr. Samuel Collins, Administrator - Region I U. S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 U. S. Nuclear Regulatory Commission Attn: Mr. R. Ennis, Licensing Project Manager - Salem Mail Stop 08B1 Washington, DC 20555-0001 USNRC Senior Resident Inspector - Salem (X24)
Mr. P. Mulligan, Manager IV Bureau of Nuclear Engineering P.O. Box 415 Trenton, NJ 08625 Document Control Desk LR-N07-0183
- 1. Please discuss whether the growth rates for the indications due to anti-vibration bar wear and cold leg thinning (CLT) are consistent with historical experience. In addition, discuss whether these indications (particularly the CLT indications) satisfy the structural integrity performance criteria.
Anti Vibration Bars (AVB) wear and CLT growth (wear) rates observed during outage 2R15 were relatively consistent as compared to previous Salem Unit 2 experience and considering the compounding effects of Non Destructive Examination (NDE) sizing uncertainty. For example, the 9 5 th percentile AVB wear growth rate for 2R14 was estimated at approximately 4.6% Through Wall/Effective Full Power Year (TW/EFPY), as compared to approximately 2.9%
TW/EFPY for 2R1 5. A similar discussion for CLT provided an estimated growth rate for 2R14 at approximately 7% TW/EFPY (average structural depth), as compared to approximately 13% TW/EFPY (average structural depth) for 2R15.
The growth rate estimates for AVB and CLT are an overestimate of actual physical growth rate, since NDE sizing uncertainty is included. No attempt was made to remove the effects of NDE sizing uncertainty since the conservative growth rate provided an acceptable structural margin. Assessment of these indications was performed consistent with the guidance and requirements provided from NEI 97-06 "Steam Generator Program Guidelines," EPRI Tube Integrity Assessment Guidelines, EPRI Steam Generator Degradation Specific Management Flaw Handbook, and the EPRI Steam Generator In Situ Pressure Test Guidelines. All of the AVB wear and CLT indications burst pressures were calculated well above the structural integrity performance criteria burst pressure limit, and as such satisfied the structural integrity performance criteria.
1 Document Control Desk LR-N07-0183
- 2. Page 8 of Attachment I to your submittal dated March 1, 2007, states that the "total postulated accident leakage is estimated to be much less than the total allowable for all SGs (1 gpm [gallon per minute]), and any single SG (0.6 gpm)." In your Salem Unit 2 amendment request dated April 6, 2006, related to Technical Specification Task Force (TSTF) traveler TSTF-449, it appears that the only limit cited for accident-induced leakage was I gpm for all SGs. Please clarify your accident-induced leakage criteria for all design-basis accidents that are assumed to have primary-to-secondary leakage.
Copies of design-basis accident analyses supporting Salem's full implementation of alternative source term (AST) were submitted to the NRC and approved via License Amendments 271 and 252 (Ref. TAC Nos. MC3094 and MC3095).
Further clarification was also provided in response to Request for Additional Information (RAI) number 9 in LR-N06-0277. Consistent with and subsequent to response number 9 in LR-NO6-0277, PSEG revised the accident analysis calculations with limiting assumptions of 0.6 gpm primary-to-secondary (PTS) leakage in the affected Steam Generator (SG) and 1.0 gpm total PTS leakage for all SGs. Apportioned PTS leakage is used in the Main Steam Line Break and Locked Rotor Accidents. PTS leakage of 1.0 gpm in a single SG is used in the Steam Generator Tube Rupture and Control Rod Ejection (CRE) Accidents.
Therefore, the limiting accident-induced leakage criteria for all design basis accidents (DBAs) are the PTS leakage of 1.0 gpm for all SGs and 0.6 gpm in any single SG.
2 Document Control Desk LR-N07-0183
- 3. The leakage for the WEXTEX region, the top of tubesheet transition region, and from tube plugs was assessed in the letter dated March 1, 2007.
Please discuss whether any other indications detected during the outage would have leaked under postulated accident conditions. In addition, discuss the amount of leakage expected from these indications and provide the total accident-induced leakage from all sources.
No other indications detected during the outage would have leaked under postulated accident conditions. Therefore, the accident-induced leakage assessment provided in the letter dated March 1, 2007 for the WEXTEX region, the top of tubesheet transition region, and from tube plugs is the total accident-induced leakage from all sources. The total leak rate is estimated to be less than 0.36 gpm for the worst-case steam generator and total for all steam generators.
3 Document Control Desk LR-N07-0183
- 4. Please provide an assessment of the severity of the single axial indications and the single circumferential indications detected at the tube support plate elevations. Did these indications satisfy the structural integrity performance criteria?
The table below supplements the information supplied in the March 1, 2007 letter. As shown below, all the tube support plate indications are relatively short in axial/circumferential length and with maximum depth (%TVV) measured much less than through-wall. Assessment of these indications was performed consistent with the guidance and requirements provided from NEI 97-06 "Steam Generator Program Guidelines," EPRI Tube Integrity Assessment Guidelines, EPRI Steam Generator Degradation Specific Management Flaw Handbook, and the EPRI Steam Generator In Situ Pressure Test Guidelines. The calculated burst pressures for the indications are well above the structural integrity performance criteria burst pressure limit and more than half of the indications demonstrated a Plus Point voltage less than 0.5 volts (EPRI Steam Generator In Situ Pressure Test Guidelines), and as such satisfied the structural integrity performance criteria.
TSP Indications Plus Point Data Axial ARC Max SG Row Col Location Length Deg ID/OD Volts %TW Ind Inches SG21 5 38 01H 0.33 ID 0.88 44 SAI SG21 5 41 01H 0.08 ID 0.74 27 SAI SG21 6 41 01H 0.41 ID 0.65 26 SAI SG21 6 65 02H 0.19 ID 0.37 28 SAI SG21 10 12 01H 0.38 ID 0.49 21 SAI SG21 12 13 02H 0.13 ID 0.37 29 SAI SG21 19 28 01H 39 OD 0.22 38 SCI SG21 20 27 01H 0.27 OD 0.15 27 SAI SG21 21 37 03H 0.41 ID 0.81 36 SAI SG22 9 56 01H 0.38 ID 0.37 49 SAI SG24 12 4 01H 0.31 ID 0.4 29 SAI SG24 20 64 01H 0.26 ID 0.71 38 SAI SG24 20 64 01H 0.31 ID 0.72 44 SAI SG24 23 82 02H 0.18 OD 0.12 30 SAl 4
Document Control Desk LR-N07-0183
- 5. Please discuss whether the inspection data acquired for the permeability variation indications was adequate to determine whether the area may have had a significant flaw. If not, please discuss how tube integrity was assessed at these locations (i.e., in-situ testing).
Permeability Variation (PVN) is a condition where the test coil impedance changes due to a change in the tubing material's inherent willingness to conduct magnetic flux lines. PVN signals are not considered to be flaws or degradation.
Rather, the signals are considered data quality issues that require additional testing using a magnetically biased rotating coil probe to disposition. During 2R1 5, conservative changes were made relative to the identification of PVN signals based on bobbin coil response. A quantitative bobbin voltage value of equal to or greater than 5 volts was used to identify locations for supplemental magnetically biased Plus Point testing. This resulted in the identification of four areas of tubing (table below) that required follow-up testing. The results of this testing did not reveal any flaw-like response indicative of degradation in the area of interest; however, low level permeability variations were noted. PSEG made the conservative decision to preventively plug these tubes. It is expected that any flaws or degradation in the area where PVN was reported would result in a change in signal response when compared to previous inspection data. Based on review of 2R1 2 bobbin coil data (2002 timeframe), there were no observed changes in the signals.
The last location (Row 7 Column 41 in 22 SG) is routinely inspected as part of the base scope Top of the Tube Sheet (TTS) Plus Point inspection program. The bobbin coil data for this location did not reveal any data quality concerns. There was no flaw-like response observed in the magnetically biased Plus Point data; however, low level PVN was observed. Therefore, PSEG made the conservative decision to preventatively plug this tube. Based on review to 2R12, there were no changes in the Plus Point signal response at this location. In addition, the locations identified with permeability variation are in locations not typically conducive to degradation (e.g., freespan). The locations identified with permeability variation are as follows and were preventatively plugged:
SG Tube ID Bobbin Coil at Location Location 21 R12C24 PVN 03C + 14.40 21 R23C40 PVN 02C + 25.63 22 R14C9 PVN 02H + 16.88 22 R15C18 PVN 02H + 41.27 22 R7C41 NDD TSH + 1.73 With the absence of degradation at the locations listed above, tube integrity is demonstrated.