MONTHYEARL-MT-23-042, 2023 Annual Report of Changes in Emergency Core Cooling System Evaluation Models Pursuant to 10 CFR 50.462023-12-11011 December 2023 2023 Annual Report of Changes in Emergency Core Cooling System Evaluation Models Pursuant to 10 CFR 50.46 L-MT-21-033, 2020 Annual Radioactive Effluent Release Report2021-05-13013 May 2021 2020 Annual Radioactive Effluent Release Report L-MT-20-045, 2020 Annual Report of Changes in Emergency Core Cooling System Evaluation Models Pursuant to 10 CFR 50.462020-12-16016 December 2020 2020 Annual Report of Changes in Emergency Core Cooling System Evaluation Models Pursuant to 10 CFR 50.46 L-MT-18-071, Annual Report of Changes in Emergency Core Cooling System Evaluation Models Pursuant to 10 CFR 50.462018-12-12012 December 2018 Annual Report of Changes in Emergency Core Cooling System Evaluation Models Pursuant to 10 CFR 50.46 L-MT-17-086, Annual Report of Changes in Emergency Core Cooling System Evaluation Models Pursuant to 10 CFR 50.462017-12-15015 December 2017 Annual Report of Changes in Emergency Core Cooling System Evaluation Models Pursuant to 10 CFR 50.46 L-MT-17-037, 2016 Annual Radiological Environmental Operating Report2017-05-10010 May 2017 2016 Annual Radiological Environmental Operating Report L-MT-16-071, Submittal of 2016 Annual Report of Changes in Emergency Core Cooling System Evaluation Models Pursuant to 10 CFR 50.462016-12-19019 December 2016 Submittal of 2016 Annual Report of Changes in Emergency Core Cooling System Evaluation Models Pursuant to 10 CFR 50.46 L-MT-16-027, Annual Report of Changes in Areva Emergency Core Cooling System Evaluation Models Pursuant to 10 CFR 50.462016-05-24024 May 2016 Annual Report of Changes in Areva Emergency Core Cooling System Evaluation Models Pursuant to 10 CFR 50.46 L-MT-15-091, Submittal of 2015 Annual Report of Changes in Emergency Core Cooling System Evaluation Models Pursuant to 10 CFR 50.462015-12-22022 December 2015 Submittal of 2015 Annual Report of Changes in Emergency Core Cooling System Evaluation Models Pursuant to 10 CFR 50.46 L-MT-14-101, Annual Report of Changes in Emergency Core Cooling System Evaluation Models Pursuant to 10 CFR 50.462014-12-30030 December 2014 Annual Report of Changes in Emergency Core Cooling System Evaluation Models Pursuant to 10 CFR 50.46 L-MT-13-116, 2013 Annual Report of Changes and Errors in Emergency Core Cooling System Evaluation Models2013-12-27027 December 2013 2013 Annual Report of Changes and Errors in Emergency Core Cooling System Evaluation Models L-MT-13-042, Submittal of 2012 Annual Radiological Environmental Operating Report2013-05-10010 May 2013 Submittal of 2012 Annual Radiological Environmental Operating Report L-MT-13-037, 2012 Annual Report of Individual Monitoring2013-04-18018 April 2013 2012 Annual Report of Individual Monitoring L-MT-12-106, Submission of 10CFR72.48 Report Re Changes to Spent Fuel Storage Cask Design and Any Tests, Experiments or Procedures Changes for 10/04/2011 to 10/30/20122012-11-29029 November 2012 Submission of 10CFR72.48 Report Re Changes to Spent Fuel Storage Cask Design and Any Tests, Experiments or Procedures Changes for 10/04/2011 to 10/30/2012 L-MT-12-042, Submittal of 2011 Annual Radiological Environmental Operating Report2012-05-10010 May 2012 Submittal of 2011 Annual Radiological Environmental Operating Report ML12114A0132012-04-18018 April 2012 Submittal of 2011 Annual Report of Individual Monitoring L-MT-11-020, 2010 Annual Radiological Environmental Operating Report2011-05-12012 May 2011 2010 Annual Radiological Environmental Operating Report L-MT-11-021, Submittal of 2010 Radioactive Effluent Release Report2011-05-12012 May 2011 Submittal of 2010 Radioactive Effluent Release Report L-MT-10-075, 2010 Report of Changes and Errors in ECCS Evaluation Models for July 2009 Through July 20102010-12-20020 December 2010 2010 Report of Changes and Errors in ECCS Evaluation Models for July 2009 Through July 2010 L-MT-08-081, Report of Changes and Errors in ECCS Evaluation Models2008-12-30030 December 2008 Report of Changes and Errors in ECCS Evaluation Models L-MT-04-012, Annual Report of Safety Relief Valve Failures and Challenges, January 1 Through December 31, 20032004-02-18018 February 2004 Annual Report of Safety Relief Valve Failures and Challenges, January 1 Through December 31, 2003 L-MT-03-077, 2003 Report of Changes and Errors in ECCS Evaluation Models2003-10-16016 October 2003 2003 Report of Changes and Errors in ECCS Evaluation Models M200204, Annual Radiological Environmental Operating Report2002-05-15015 May 2002 Annual Radiological Environmental Operating Report ML0214300222002-05-15015 May 2002 Part a - Monticello Nuclear Generating Plant 2001 Radioactive Effluent Release Report 2023-12-11
[Table view] Category:Letter type:L
MONTHYEARL-MT-23-054, Subsequent License Renewal Application Supplement 82024-01-11011 January 2024 Subsequent License Renewal Application Supplement 8 L-MT-23-047, License Amendment Request: Revision to the MNGP Pressure Temperature Limits Report to Change the Neutron Fluence Methodology and Incorporate New Surveillance Capsule Data2023-12-29029 December 2023 License Amendment Request: Revision to the MNGP Pressure Temperature Limits Report to Change the Neutron Fluence Methodology and Incorporate New Surveillance Capsule Data L-MT-23-056, Subsequent License Renewal Application Response to Request for Additional Information and Request for Confirmation of Information - Set 1 Part 22023-12-18018 December 2023 Subsequent License Renewal Application Response to Request for Additional Information and Request for Confirmation of Information - Set 1 Part 2 L-MT-23-042, 2023 Annual Report of Changes in Emergency Core Cooling System Evaluation Models Pursuant to 10 CFR 50.462023-12-11011 December 2023 2023 Annual Report of Changes in Emergency Core Cooling System Evaluation Models Pursuant to 10 CFR 50.46 L-MT-23-052, Subsequent License Renewal Application Supplement 72023-11-30030 November 2023 Subsequent License Renewal Application Supplement 7 L-MT-23-051, Update to the Technical Specification Bases2023-11-28028 November 2023 Update to the Technical Specification Bases L-MT-23-049, Subsequent License Renewal Application Response to Request for Additional Information and Request for Confirmation of Information - Set 12023-11-21021 November 2023 Subsequent License Renewal Application Response to Request for Additional Information and Request for Confirmation of Information - Set 1 L-MT-23-043, 10 CFR 50.55a(z)(1) Request Regarding OMN-17, Revision 1. VR-092023-11-13013 November 2023 10 CFR 50.55a(z)(1) Request Regarding OMN-17, Revision 1. VR-09 L-MT-23-038, License Amendment Request to Revise Monticello Technical Specification Surveillance Requirement 3.8.6.62023-11-10010 November 2023 License Amendment Request to Revise Monticello Technical Specification Surveillance Requirement 3.8.6.6 L-MT-23-046, Subsequent License Renewal Application Response to Request for Additional Information Round 2 - Set 12023-11-0909 November 2023 Subsequent License Renewal Application Response to Request for Additional Information Round 2 - Set 1 L-MT-23-041, Subsequent License Renewal Application Response to Request for Confirmation of Information Set 22023-10-0303 October 2023 Subsequent License Renewal Application Response to Request for Confirmation of Information Set 2 L-MT-23-037, Subsequent License Renewal Application Response to Request for Additional Information Set 32023-09-22022 September 2023 Subsequent License Renewal Application Response to Request for Additional Information Set 3 L-MT-23-036, Subsequent License Renewal Application Response to Request for Additional Information Set 2 and Supplement 62023-09-0505 September 2023 Subsequent License Renewal Application Response to Request for Additional Information Set 2 and Supplement 6 L-MT-23-035, Subsequent License Renewal Application Supplement 52023-08-28028 August 2023 Subsequent License Renewal Application Supplement 5 L-MT-23-034, Subsequent License Renewal Application Response to Request for Additional Information Set 12023-08-15015 August 2023 Subsequent License Renewal Application Response to Request for Additional Information Set 1 L-MT-23-028, 2023 Refueling Outage 90-Day Inservice Inspection (ISI) Summary Report2023-07-31031 July 2023 2023 Refueling Outage 90-Day Inservice Inspection (ISI) Summary Report L-MT-23-032, 10 CFR 50.55a(z)(2) Request Regarding MO-2397, VR-112023-07-31031 July 2023 10 CFR 50.55a(z)(2) Request Regarding MO-2397, VR-11 L-MT-23-031, Subsequent License Renewal Application Supplement 4 and Responses to Request for Confirmation of Information - Set 12023-07-18018 July 2023 Subsequent License Renewal Application Supplement 4 and Responses to Request for Confirmation of Information - Set 1 L-MT-23-030, Subsequent License Renewal Application Supplement 32023-07-0404 July 2023 Subsequent License Renewal Application Supplement 3 L-MT-23-025, Subsequent License Renewal Application Supplement 22023-06-26026 June 2023 Subsequent License Renewal Application Supplement 2 L-MT-23-019, Submittal of 2022 Annual Radiological Environmental Operating Report2023-05-10010 May 2023 Submittal of 2022 Annual Radiological Environmental Operating Report L-MT-23-020, Submittal of 2022 Annual Radioactive Effluent Release Report2023-05-10010 May 2023 Submittal of 2022 Annual Radioactive Effluent Release Report L-MT-23-021, Core Operating Limits Report (COLR) for the Monticello Nuclear Generating Plant for Cycle 322023-05-0202 May 2023 Core Operating Limits Report (COLR) for the Monticello Nuclear Generating Plant for Cycle 32 L-MT-23-017, 2022 Annual Report of Individual Monitoring for the Monticello Nuclear Generating Plant (MNGP)2023-04-18018 April 2023 2022 Annual Report of Individual Monitoring for the Monticello Nuclear Generating Plant (MNGP) L-MT-23-010, Subsequent License Renewal Application Supplement 12023-04-0303 April 2023 Subsequent License Renewal Application Supplement 1 L-MT-23-013, Core Operating Limits Report (COLR) for Cycle 31, Revision 32023-03-28028 March 2023 Core Operating Limits Report (COLR) for Cycle 31, Revision 3 L-MT-23-012, Core Operating Limits Report (COLR) for Monticello Nuclear Generating Plant Cycle 31, Revision 22023-03-17017 March 2023 Core Operating Limits Report (COLR) for Monticello Nuclear Generating Plant Cycle 31, Revision 2 L-MT-23-008, 10CFR50.55a Request to Use Later Edition of ASME Section XI for ISI Code of Record (RR-003)2023-02-0707 February 2023 10CFR50.55a Request to Use Later Edition of ASME Section XI for ISI Code of Record (RR-003) L-MT-23-004, CFR 50.55a Request RR-001, Request to Use a Provision of a Later Edition of the ASME Boiler and Pressure Vessel Code, Section XI for the Monticello Third Interval Containment Inservice Inspection Program2023-01-23023 January 2023 CFR 50.55a Request RR-001, Request to Use a Provision of a Later Edition of the ASME Boiler and Pressure Vessel Code, Section XI for the Monticello Third Interval Containment Inservice Inspection Program L-MT-23-005, Response to the NRC Request for Additional Information Regarding the 50.55a Request Pr 08, HPCI Pump Quarterly Testing (EPID Number L-2022-LLR-0088)2023-01-0606 January 2023 Response to the NRC Request for Additional Information Regarding the 50.55a Request Pr 08, HPCI Pump Quarterly Testing (EPID Number L-2022-LLR-0088) L-MT-22-049, Industry Groundwater Protection Initiative Special Report2022-12-15015 December 2022 Industry Groundwater Protection Initiative Special Report L-MT-22-052, L-MT-22-052 Monticello Nuclear Generating Plant 10 CFR 50.55a Request No. Pr 08, Request for HPCI Pump Quarterly Alternative2022-12-15015 December 2022 L-MT-22-052 Monticello Nuclear Generating Plant 10 CFR 50.55a Request No. Pr 08, Request for HPCI Pump Quarterly Alternative L-MT-22-046, 2022 Annual Report of Changes in Emergency Core Cooling System Evaluation Models Pursuant to 10 CFR 50.462022-12-13013 December 2022 2022 Annual Report of Changes in Emergency Core Cooling System Evaluation Models Pursuant to 10 CFR 50.46 L-MT-22-048, Update to the Monticello Technical Specification Bases2022-11-28028 November 2022 Update to the Monticello Technical Specification Bases L-MT-22-047, Withdrawal of Request for Relief from ASME OM Code for the Sixth Inservice Testing Interval2022-11-10010 November 2022 Withdrawal of Request for Relief from ASME OM Code for the Sixth Inservice Testing Interval L-MT-22-045, Letter Submitting Post-Exam Package2022-11-0404 November 2022 Letter Submitting Post-Exam Package L-MT-22-030, Sixth Interval Inservice Testing (1ST) Plan2022-09-0606 September 2022 Sixth Interval Inservice Testing (1ST) Plan L-MT-22-037, Supplement to 10 CFR 50.55a Request Associated with the Monticello Sixth Inservice Testing Ten-Year Interval, Alternative VR-10, Excess Flow Check Valve Testing Frequency2022-08-29029 August 2022 Supplement to 10 CFR 50.55a Request Associated with the Monticello Sixth Inservice Testing Ten-Year Interval, Alternative VR-10, Excess Flow Check Valve Testing Frequency L-MT-22-007, Response to Request for Additional Information for the Monticello Nuclear Generating Plant Alternative Request VR-08 (EPID: L-MT-22-007)2022-07-22022 July 2022 Response to Request for Additional Information for the Monticello Nuclear Generating Plant Alternative Request VR-08 (EPID: L-MT-22-007) L-MT-22-026, Changes to the Emergency Plan2022-07-19019 July 2022 Changes to the Emergency Plan L-MT-22-024, Response to a Request for Additional Information for the Monticello Nuclear Generating Plant Related to the Amendment to Adopt Advanced Framatome Methodologies2022-06-0606 June 2022 Response to a Request for Additional Information for the Monticello Nuclear Generating Plant Related to the Amendment to Adopt Advanced Framatome Methodologies L-MT-22-022, Response to a Request for Additional Information: Monticello Alternative VR-10, Excess Flow Check Valve Testing Frequency2022-05-25025 May 2022 Response to a Request for Additional Information: Monticello Alternative VR-10, Excess Flow Check Valve Testing Frequency L-MT-22-017, 2021 Annual Radiological Environmental Operating Report2022-05-11011 May 2022 2021 Annual Radiological Environmental Operating Report L-MT-22-018, 2021 Annual Radioactive Effluent Release Report2022-05-11011 May 2022 2021 Annual Radioactive Effluent Release Report L-MT-22-016, 2021 Annual Report of Individual Monitoring2022-04-28028 April 2022 2021 Annual Report of Individual Monitoring L-MT-22-019, Withdrawal of Requests for Relief from ASME OM Code for the Sixth Inservice Testing Interval2022-04-18018 April 2022 Withdrawal of Requests for Relief from ASME OM Code for the Sixth Inservice Testing Interval L-MT-22-010, License Amendment Request to Revise Technical Specification 3.6.1.8 Residual Heat Removal (RHR) Drywell Spray Header and Nozzle Surveillance Frequency2022-03-18018 March 2022 License Amendment Request to Revise Technical Specification 3.6.1.8 Residual Heat Removal (RHR) Drywell Spray Header and Nozzle Surveillance Frequency L-MT-22-012, Special Report for the Bypass of the Offgas Treatment Storage System2022-03-15015 March 2022 Special Report for the Bypass of the Offgas Treatment Storage System L-MT-22-008, 10 CFR 50.55a Request Associated with the Monticello Sixth Inservice Testing Ten-Year Interval Alternative Related to Excess Flow Check Valve Testing Frequency (L-MT-22-008)2022-03-0707 March 2022 10 CFR 50.55a Request Associated with the Monticello Sixth Inservice Testing Ten-Year Interval Alternative Related to Excess Flow Check Valve Testing Frequency (L-MT-22-008) L-MT-22-006, 10 CFR 50.55a Request Associated with the Monticello Sixth Inservice Testing Ten-Year Interval OMN-26 (L-MT-22-006)2022-02-18018 February 2022 10 CFR 50.55a Request Associated with the Monticello Sixth Inservice Testing Ten-Year Interval OMN-26 (L-MT-22-006) 2024-01-11
[Table view] |
Text
Xcel Energy Monticello Nuclear Generating Plant 2807 W County Road 75 Monticello, MN 55362 December 15, 2017 L-MT-17-086 10 CFR 50.46(a)(3)(ii)
U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 Monticello Nuclear Generating Plant*
Docket No. 50-263 Renewed Facility Operating License No. DPR-22 2017 Annual Report of Changes in Emergency Core Cooling System Evaluation Models Pursuant to 10 CFR 50.46
References:
- 1) Letter from P. Gardner (NSPM) to NRC, "2016 Annual Report of Changes in Emergency Core Cooling System Evaluation Models Pursuant to 10 CFR 50.46," (L-MT-16-071), dated December 19, 2016
- 2) Letter from P. Gardner (NSPM) to NRC, "June 2017, Thirty-Day Report of Changes in Emergency Core Cooling System Evaluation Models Pursuant to 10 CFR 50.46," (L-MT-17-045), dat-ed June 22, 2017 Pursuant to 10 CFR 50.46(a)(3)(ii), the Northern States Power Company, a Minnesota corporation (NSPM), doing business as Xcel Energy, is providing this annual report concerning changes or errors identified in the Emergency Core Cooling System (ECCS) evaluation models for the Monticello Nuclear Generating Plant (MNGP).
Provided within Enclosure 1 is a report concerning any changes or errors identified in the AREVA ECCS evaluation models for MNGP. This report is for the period between July 2016 and July 2017 for the ATRIUM 10XM fuel. During this period there was a notification of changes or errors resulting in a change to the calculated Peak Clad Temperature (PCT) of 51 oF and therefore reported in a 30-day report (Reference 2).
There have been no additional changes since that report. The previously report PCT of 2085oF for the ATRIUM 1OXM fuel since the 30-day report is unchanged.
Provided within Enclosure 2 is a report concerning any changes or errors identified in the General Electric-Hitachi (GEH) ECCS evaluation models for MNGP. This report is for the period between July 2016 and July 2017 for the General Electric (GE) GE14 fuel.
During this period no notification of any changes or errors resulting in a change to the calculated PCT were received from GEH. Therefore the PCT of less than 2170°F for the GE14 fuel and the PCT summary provided in the 2016 annual report (Reference 1) is unchanged.
Document Control Desk L-MT-17-086 Page 2 of 2 Until all the GE14 fuel is permanently discharged from the MNGP core, the annual ECCS reports will continue to be provided for the associated GEH evaluation models (GE14 fuel) and AREVA evaluation models (ATRIUM 10XM fuel).
Should you have questions regarding this letter, please contact Mr. Stephen Sollom at (763) 295-1611.
Summary of Commitments This letter proposes no new commitments and does not revise any existing commitments.
~{Zntf-
-~r C. CLtufM4.,
Christoph r urch Site Vice si ent, Monticello Nuclear Generating Plant Northern States Power Company- Minnesota Enclosures (2) cc: Administrator, Region Ill, USNRC Project Manager, Monticello, USNRC Resident Inspector, Monticello, USNRC
ENCLOSURE 1 MONTICELLO NUCLEAR GENERATING PLANT
SUMMARY
OF MONTICELLO LOCA CHANGES AND ERRORS INVOLVING CHANGES IN PEAK CLADDING TEMPERATURE (PCT) FOR ATRIUM 1 OXM FUEL (2 page follows)
L-MT-17-086 Enclosure 1 Page 1 of 2 TABLE-
SUMMARY
OF MONTICELLO LOCA CHANGES AND ERRORS INVOLVING CHANGES IN PEAK CLADDING TEMPERATURE (PCT) FOR ATRIUM 10XM FUEL Licensing Basis Applicable Analysis or Error I Change Description Ref. PCT(°F)
ATRIUM 10XM ANP-3558P Revision 0, "Monticello LOCA MAPLHGR Limits for EPU/EFWwith ATRIUM 10XM Fuel and Revised ECCS A1 2034 Parameters" (1)
MSIV Closure The impact of this MSIV closure change was estimated for the A2 +51 Monticello LOCA break spectrum and exposure-dependent MAPLHGR analyses.
Sum of absolute value of changes for the current reporting period, which 51 includes all changes since the 10 CFR 50.46 report Reference A 1.(2)
Sum of absolute value of changes since last analysis of record (AOR) 51 (Reference A 1).
Algebraic sum of changes for the current reporting period, which includes all
+51 changes since the 10 CFR 50.46 report in Reference A1.( 2)
Algebraic sum of changes since last AOR (Reference A 1). +51 Current Adjusted Peak Cladding Temperature 2085 1
( ) AREVA report ANP-3558P reflects a new LOCA analysis performed to provide a new baseline for the AREVA ATRIUM 10XM fuel at the MNGP as provided to the NRC in Reference A3.
2
( ) Since a new baseline was established during the reporting period, only the changes since the new baseline are required.
References A 1. AREVA Report ANP-3558P Revision 0, "Monticello LOCA MAPLHGR Limits for EPU/EFW with ATRIUM 1OXM Fuel and Revised ECCS Parameters," January 2017.
L-MT -17 ~086 Page 2 of 2 A2. AREVA Report FS1-0032297 Revision 1, "Monticello 10 CFR 50.46 PCT Reporting for ATRIUM 10XM Fuel Through May 2017," May 25, 2017.
A3. Letter from P. Gardner (NSPM) to NRC, "June 2017, Thirty-Day Report of Changes in Emergency Core Cooling System Evaluations Models Pursuant to 10 CFR 50.46," (L-MT-17-045) dated June 22, 2017.
ENCLOSURE 2 MONTICELLO NUCLEAR GENERATING PLANT
SUMMARY
OF MONTICELLO LOCA CHANGES AND ERRORS INVOLVING CHANGES IN PEAK CLADDING TEMPERATURE FOR (PCT) FOR GE14 FUEL (3 pages follow)
L-MT-17-086 Page 1 of 3 TABLE-
SUMMARY
OF MONTICELLO LOCA CHANGES AND ERRORS INVOLVING CHANGES IN PEAK CLADDING TEMPERATURE (PCT) FOR GE14 FUEL Licensing Basis Applicable Analysis or Error I Change Description Ref.
PCT(°F)
GE14 NEDC-33322P, Revision 3, "Safety Analysis Report for G1&
<2140 Monticello Constant Pressure Power Uprate" G2 PRIME Fuel Properties Implementation for Fuel Rod T/M Performance, replacing GESTR Fuel Properties (1 0 CFR 50.46 Notification Letter 2012-01, Revision 1)
This change is due to the application of an NRC-approved G3 +10 procedure to estimate the change in Peak Clad Temperature (PCT) due to the change in fuel properties from GESTR to PRIME primarily to address inaccuracies in fuel pellet thermal conductivity as a function of exposure.
SAFER04A E4-Maintenance Update Changes (1 0 CFR 50.46 Notification Letter 2014-01)
This change is for a new version (E4) of SAFER04A that G4 +0 resolves several accumulated observations that are code maintenance items. Sensitivity calculations show these items have an insignificant effect on calculated PCT.
SAFER04A E4-Mass Non-Conservatism (1 0 CFR 50.46 Notification Letter 2014-02)
This change is due to a logic error that occurs when upper plenum liquid mass and core spray flow rate are low. System G5 +15 mass is gradually lost due to core spray being discarded, resulting in marginally less ECCS flow credited as reaching the core.
SAFER04A E4-Minimum Core DP Model (1 0 CFR 50.46 Notification Letter 20 14-03)
This change is due to the use of a minimum ~p that could be G6 +20 non-conservative offering inappropriate steam cooling benefit above the core two-phase level.
L-MT-17-086 Page 2 of 3 TABLE-
SUMMARY
OF MONTICELLO LOCA CHANGES AND ERRORS INVOLVING CHANGES IN PEAK CLADDING TEMPERATURE (PCT) FOR GE14 FUEL Licensing Basis Applicable Analysis or Error I Change Description Ref.
PCT(°F)
GE14 SAFER04A E4-Bundle/Lower Plenum CCFL Head (1 0 CFR 50.46 Notification Letter 2014-04)
This change is due to the counter current flow limitation (CCFL) G7 -15 calculation representing the pressure head slightly different from that of the calculated water level in the bundle.
Sum of absolute value of changes for the current reporting period, which includes all changes since the 10 CFR 50.46 report. 0 Sum of absolute value of changes since last AOR (Reference G1). 60 Algebraic sum of changes for the current reporting period, which includes all changes since the 10 CFR 50.46 report in Reference G8. +0 Algebraic sum of changes since last AOR (Reference G1 ). +30 Current Adjusted Peak Cladding Temperature <2170 References G1. GE Report: NEDC-33322P Revision 3, "Safety Analysis Report for Monticello Constant Pressure Power Uprate," dated October 2008 (Enclosure 5 of NSPM (T. O'Connor) to NRC, "License Amendment Request: Extended Power Uprate (TAC MD9990)," L-MT-08-052, dated November 5, 2008, ADAMS Accession No. ML083230111 ).
G2. NSPM (M. Schimmel) to NRC, "Monticello Extended Power Uprate and Maximum Extended Load Line Limit Analysis Plus License Amendment Requests:
Supplement for Analytical Methods Used to Address Thermal Conductivity Degradation and Analytical Methods Limitations (TAC Nos. MD9990 and ME3145),"
L-MT-13-053, dated July 8, 2013 (ADAMS Accession No. ML13191A568).
G3. GEH 10 CFR 50.46 Notification Letter 2012-01, Revision 1, "PRIME Fuel Properties Implementation for Fuel Rod T/M Performance, replacing GESTR Fuel Properties,"
dated July 30, 2013.
G4. GEH 10 CFR 50.46 Notification Letter 2014-01, "SAFER04A E4-Maintenance Update Changes," dated May 21, 2014.
L-MT-17-086 Page 3 of 3 G5. GEH 10 CFR 50.46 Notification Letter 2014-02, "SAFER04A E4-Mass Non-Conservatism," dated May 21, 2014.
G6. GEH 10 CFR 50.46 Notification Letter 2014-03, "SAFER04A E4-Minimum Core DP Model," dated May 21, 2014.
G7. GEH 10 CFR 50.46 Notification Letter 2014-04, "SAFER04A E4-Bundle/Lower Plenum CCFL Head," dated May 21, 2014.
G8. L-MT-16-071, letter from P. Gardner (NSPM) to U.S. Nuclear Regulatory Commission, "2016 Annual Report of Changes in Emergency Core Cooling System Evaluation Models Pursuant to 10 CFR 50.46," December 19, 2016.