MONTHYEARL-MT-23-042, 2023 Annual Report of Changes in Emergency Core Cooling System Evaluation Models Pursuant to 10 CFR 50.462023-12-11011 December 2023 2023 Annual Report of Changes in Emergency Core Cooling System Evaluation Models Pursuant to 10 CFR 50.46 L-MT-21-033, 2020 Annual Radioactive Effluent Release Report2021-05-13013 May 2021 2020 Annual Radioactive Effluent Release Report L-MT-20-045, 2020 Annual Report of Changes in Emergency Core Cooling System Evaluation Models Pursuant to 10 CFR 50.462020-12-16016 December 2020 2020 Annual Report of Changes in Emergency Core Cooling System Evaluation Models Pursuant to 10 CFR 50.46 L-MT-18-071, Annual Report of Changes in Emergency Core Cooling System Evaluation Models Pursuant to 10 CFR 50.462018-12-12012 December 2018 Annual Report of Changes in Emergency Core Cooling System Evaluation Models Pursuant to 10 CFR 50.46 L-MT-17-086, Annual Report of Changes in Emergency Core Cooling System Evaluation Models Pursuant to 10 CFR 50.462017-12-15015 December 2017 Annual Report of Changes in Emergency Core Cooling System Evaluation Models Pursuant to 10 CFR 50.46 L-MT-17-037, 2016 Annual Radiological Environmental Operating Report2017-05-10010 May 2017 2016 Annual Radiological Environmental Operating Report L-MT-16-071, Submittal of 2016 Annual Report of Changes in Emergency Core Cooling System Evaluation Models Pursuant to 10 CFR 50.462016-12-19019 December 2016 Submittal of 2016 Annual Report of Changes in Emergency Core Cooling System Evaluation Models Pursuant to 10 CFR 50.46 L-MT-16-027, Annual Report of Changes in Areva Emergency Core Cooling System Evaluation Models Pursuant to 10 CFR 50.462016-05-24024 May 2016 Annual Report of Changes in Areva Emergency Core Cooling System Evaluation Models Pursuant to 10 CFR 50.46 L-MT-15-091, Submittal of 2015 Annual Report of Changes in Emergency Core Cooling System Evaluation Models Pursuant to 10 CFR 50.462015-12-22022 December 2015 Submittal of 2015 Annual Report of Changes in Emergency Core Cooling System Evaluation Models Pursuant to 10 CFR 50.46 L-MT-14-101, Annual Report of Changes in Emergency Core Cooling System Evaluation Models Pursuant to 10 CFR 50.462014-12-30030 December 2014 Annual Report of Changes in Emergency Core Cooling System Evaluation Models Pursuant to 10 CFR 50.46 L-MT-13-116, 2013 Annual Report of Changes and Errors in Emergency Core Cooling System Evaluation Models2013-12-27027 December 2013 2013 Annual Report of Changes and Errors in Emergency Core Cooling System Evaluation Models L-MT-13-042, Submittal of 2012 Annual Radiological Environmental Operating Report2013-05-10010 May 2013 Submittal of 2012 Annual Radiological Environmental Operating Report L-MT-13-037, 2012 Annual Report of Individual Monitoring2013-04-18018 April 2013 2012 Annual Report of Individual Monitoring L-MT-12-106, Submission of 10CFR72.48 Report Re Changes to Spent Fuel Storage Cask Design and Any Tests, Experiments or Procedures Changes for 10/04/2011 to 10/30/20122012-11-29029 November 2012 Submission of 10CFR72.48 Report Re Changes to Spent Fuel Storage Cask Design and Any Tests, Experiments or Procedures Changes for 10/04/2011 to 10/30/2012 L-MT-12-042, Submittal of 2011 Annual Radiological Environmental Operating Report2012-05-10010 May 2012 Submittal of 2011 Annual Radiological Environmental Operating Report ML12114A0132012-04-18018 April 2012 Submittal of 2011 Annual Report of Individual Monitoring L-MT-11-020, 2010 Annual Radiological Environmental Operating Report2011-05-12012 May 2011 2010 Annual Radiological Environmental Operating Report L-MT-11-021, Submittal of 2010 Radioactive Effluent Release Report2011-05-12012 May 2011 Submittal of 2010 Radioactive Effluent Release Report L-MT-10-075, 2010 Report of Changes and Errors in ECCS Evaluation Models for July 2009 Through July 20102010-12-20020 December 2010 2010 Report of Changes and Errors in ECCS Evaluation Models for July 2009 Through July 2010 L-MT-08-081, Report of Changes and Errors in ECCS Evaluation Models2008-12-30030 December 2008 Report of Changes and Errors in ECCS Evaluation Models L-MT-04-012, Annual Report of Safety Relief Valve Failures and Challenges, January 1 Through December 31, 20032004-02-18018 February 2004 Annual Report of Safety Relief Valve Failures and Challenges, January 1 Through December 31, 2003 L-MT-03-077, 2003 Report of Changes and Errors in ECCS Evaluation Models2003-10-16016 October 2003 2003 Report of Changes and Errors in ECCS Evaluation Models M200204, Annual Radiological Environmental Operating Report2002-05-15015 May 2002 Annual Radiological Environmental Operating Report ML0214300222002-05-15015 May 2002 Part a - Monticello Nuclear Generating Plant 2001 Radioactive Effluent Release Report 2023-12-11
[Table view] Category:Letter type:L
MONTHYEARL-MT-23-054, Subsequent License Renewal Application Supplement 82024-01-11011 January 2024 Subsequent License Renewal Application Supplement 8 L-MT-23-047, License Amendment Request: Revision to the MNGP Pressure Temperature Limits Report to Change the Neutron Fluence Methodology and Incorporate New Surveillance Capsule Data2023-12-29029 December 2023 License Amendment Request: Revision to the MNGP Pressure Temperature Limits Report to Change the Neutron Fluence Methodology and Incorporate New Surveillance Capsule Data L-MT-23-056, Subsequent License Renewal Application Response to Request for Additional Information and Request for Confirmation of Information - Set 1 Part 22023-12-18018 December 2023 Subsequent License Renewal Application Response to Request for Additional Information and Request for Confirmation of Information - Set 1 Part 2 L-MT-23-042, 2023 Annual Report of Changes in Emergency Core Cooling System Evaluation Models Pursuant to 10 CFR 50.462023-12-11011 December 2023 2023 Annual Report of Changes in Emergency Core Cooling System Evaluation Models Pursuant to 10 CFR 50.46 L-MT-23-052, Subsequent License Renewal Application Supplement 72023-11-30030 November 2023 Subsequent License Renewal Application Supplement 7 L-MT-23-051, Update to the Technical Specification Bases2023-11-28028 November 2023 Update to the Technical Specification Bases L-MT-23-049, Subsequent License Renewal Application Response to Request for Additional Information and Request for Confirmation of Information - Set 12023-11-21021 November 2023 Subsequent License Renewal Application Response to Request for Additional Information and Request for Confirmation of Information - Set 1 L-MT-23-043, 10 CFR 50.55a(z)(1) Request Regarding OMN-17, Revision 1. VR-092023-11-13013 November 2023 10 CFR 50.55a(z)(1) Request Regarding OMN-17, Revision 1. VR-09 L-MT-23-038, License Amendment Request to Revise Monticello Technical Specification Surveillance Requirement 3.8.6.62023-11-10010 November 2023 License Amendment Request to Revise Monticello Technical Specification Surveillance Requirement 3.8.6.6 L-MT-23-046, Subsequent License Renewal Application Response to Request for Additional Information Round 2 - Set 12023-11-0909 November 2023 Subsequent License Renewal Application Response to Request for Additional Information Round 2 - Set 1 L-MT-23-041, Subsequent License Renewal Application Response to Request for Confirmation of Information Set 22023-10-0303 October 2023 Subsequent License Renewal Application Response to Request for Confirmation of Information Set 2 L-MT-23-037, Subsequent License Renewal Application Response to Request for Additional Information Set 32023-09-22022 September 2023 Subsequent License Renewal Application Response to Request for Additional Information Set 3 L-MT-23-036, Subsequent License Renewal Application Response to Request for Additional Information Set 2 and Supplement 62023-09-0505 September 2023 Subsequent License Renewal Application Response to Request for Additional Information Set 2 and Supplement 6 L-MT-23-035, Subsequent License Renewal Application Supplement 52023-08-28028 August 2023 Subsequent License Renewal Application Supplement 5 L-MT-23-034, Subsequent License Renewal Application Response to Request for Additional Information Set 12023-08-15015 August 2023 Subsequent License Renewal Application Response to Request for Additional Information Set 1 L-MT-23-028, 2023 Refueling Outage 90-Day Inservice Inspection (ISI) Summary Report2023-07-31031 July 2023 2023 Refueling Outage 90-Day Inservice Inspection (ISI) Summary Report L-MT-23-032, 10 CFR 50.55a(z)(2) Request Regarding MO-2397, VR-112023-07-31031 July 2023 10 CFR 50.55a(z)(2) Request Regarding MO-2397, VR-11 L-MT-23-031, Subsequent License Renewal Application Supplement 4 and Responses to Request for Confirmation of Information - Set 12023-07-18018 July 2023 Subsequent License Renewal Application Supplement 4 and Responses to Request for Confirmation of Information - Set 1 L-MT-23-030, Subsequent License Renewal Application Supplement 32023-07-0404 July 2023 Subsequent License Renewal Application Supplement 3 L-MT-23-025, Subsequent License Renewal Application Supplement 22023-06-26026 June 2023 Subsequent License Renewal Application Supplement 2 L-MT-23-019, Submittal of 2022 Annual Radiological Environmental Operating Report2023-05-10010 May 2023 Submittal of 2022 Annual Radiological Environmental Operating Report L-MT-23-020, Submittal of 2022 Annual Radioactive Effluent Release Report2023-05-10010 May 2023 Submittal of 2022 Annual Radioactive Effluent Release Report L-MT-23-021, Core Operating Limits Report (COLR) for the Monticello Nuclear Generating Plant for Cycle 322023-05-0202 May 2023 Core Operating Limits Report (COLR) for the Monticello Nuclear Generating Plant for Cycle 32 L-MT-23-017, 2022 Annual Report of Individual Monitoring for the Monticello Nuclear Generating Plant (MNGP)2023-04-18018 April 2023 2022 Annual Report of Individual Monitoring for the Monticello Nuclear Generating Plant (MNGP) L-MT-23-010, Subsequent License Renewal Application Supplement 12023-04-0303 April 2023 Subsequent License Renewal Application Supplement 1 L-MT-23-013, Core Operating Limits Report (COLR) for Cycle 31, Revision 32023-03-28028 March 2023 Core Operating Limits Report (COLR) for Cycle 31, Revision 3 L-MT-23-012, Core Operating Limits Report (COLR) for Monticello Nuclear Generating Plant Cycle 31, Revision 22023-03-17017 March 2023 Core Operating Limits Report (COLR) for Monticello Nuclear Generating Plant Cycle 31, Revision 2 L-MT-23-008, 10CFR50.55a Request to Use Later Edition of ASME Section XI for ISI Code of Record (RR-003)2023-02-0707 February 2023 10CFR50.55a Request to Use Later Edition of ASME Section XI for ISI Code of Record (RR-003) L-MT-23-004, CFR 50.55a Request RR-001, Request to Use a Provision of a Later Edition of the ASME Boiler and Pressure Vessel Code, Section XI for the Monticello Third Interval Containment Inservice Inspection Program2023-01-23023 January 2023 CFR 50.55a Request RR-001, Request to Use a Provision of a Later Edition of the ASME Boiler and Pressure Vessel Code, Section XI for the Monticello Third Interval Containment Inservice Inspection Program L-MT-23-005, Response to the NRC Request for Additional Information Regarding the 50.55a Request Pr 08, HPCI Pump Quarterly Testing (EPID Number L-2022-LLR-0088)2023-01-0606 January 2023 Response to the NRC Request for Additional Information Regarding the 50.55a Request Pr 08, HPCI Pump Quarterly Testing (EPID Number L-2022-LLR-0088) L-MT-22-049, Industry Groundwater Protection Initiative Special Report2022-12-15015 December 2022 Industry Groundwater Protection Initiative Special Report L-MT-22-052, L-MT-22-052 Monticello Nuclear Generating Plant 10 CFR 50.55a Request No. Pr 08, Request for HPCI Pump Quarterly Alternative2022-12-15015 December 2022 L-MT-22-052 Monticello Nuclear Generating Plant 10 CFR 50.55a Request No. Pr 08, Request for HPCI Pump Quarterly Alternative L-MT-22-046, 2022 Annual Report of Changes in Emergency Core Cooling System Evaluation Models Pursuant to 10 CFR 50.462022-12-13013 December 2022 2022 Annual Report of Changes in Emergency Core Cooling System Evaluation Models Pursuant to 10 CFR 50.46 L-MT-22-048, Update to the Monticello Technical Specification Bases2022-11-28028 November 2022 Update to the Monticello Technical Specification Bases L-MT-22-047, Withdrawal of Request for Relief from ASME OM Code for the Sixth Inservice Testing Interval2022-11-10010 November 2022 Withdrawal of Request for Relief from ASME OM Code for the Sixth Inservice Testing Interval L-MT-22-045, Letter Submitting Post-Exam Package2022-11-0404 November 2022 Letter Submitting Post-Exam Package L-MT-22-030, Sixth Interval Inservice Testing (1ST) Plan2022-09-0606 September 2022 Sixth Interval Inservice Testing (1ST) Plan L-MT-22-037, Supplement to 10 CFR 50.55a Request Associated with the Monticello Sixth Inservice Testing Ten-Year Interval, Alternative VR-10, Excess Flow Check Valve Testing Frequency2022-08-29029 August 2022 Supplement to 10 CFR 50.55a Request Associated with the Monticello Sixth Inservice Testing Ten-Year Interval, Alternative VR-10, Excess Flow Check Valve Testing Frequency L-MT-22-007, Response to Request for Additional Information for the Monticello Nuclear Generating Plant Alternative Request VR-08 (EPID: L-MT-22-007)2022-07-22022 July 2022 Response to Request for Additional Information for the Monticello Nuclear Generating Plant Alternative Request VR-08 (EPID: L-MT-22-007) L-MT-22-026, Changes to the Emergency Plan2022-07-19019 July 2022 Changes to the Emergency Plan L-MT-22-024, Response to a Request for Additional Information for the Monticello Nuclear Generating Plant Related to the Amendment to Adopt Advanced Framatome Methodologies2022-06-0606 June 2022 Response to a Request for Additional Information for the Monticello Nuclear Generating Plant Related to the Amendment to Adopt Advanced Framatome Methodologies L-MT-22-022, Response to a Request for Additional Information: Monticello Alternative VR-10, Excess Flow Check Valve Testing Frequency2022-05-25025 May 2022 Response to a Request for Additional Information: Monticello Alternative VR-10, Excess Flow Check Valve Testing Frequency L-MT-22-017, 2021 Annual Radiological Environmental Operating Report2022-05-11011 May 2022 2021 Annual Radiological Environmental Operating Report L-MT-22-018, 2021 Annual Radioactive Effluent Release Report2022-05-11011 May 2022 2021 Annual Radioactive Effluent Release Report L-MT-22-016, 2021 Annual Report of Individual Monitoring2022-04-28028 April 2022 2021 Annual Report of Individual Monitoring L-MT-22-019, Withdrawal of Requests for Relief from ASME OM Code for the Sixth Inservice Testing Interval2022-04-18018 April 2022 Withdrawal of Requests for Relief from ASME OM Code for the Sixth Inservice Testing Interval L-MT-22-010, License Amendment Request to Revise Technical Specification 3.6.1.8 Residual Heat Removal (RHR) Drywell Spray Header and Nozzle Surveillance Frequency2022-03-18018 March 2022 License Amendment Request to Revise Technical Specification 3.6.1.8 Residual Heat Removal (RHR) Drywell Spray Header and Nozzle Surveillance Frequency L-MT-22-012, Special Report for the Bypass of the Offgas Treatment Storage System2022-03-15015 March 2022 Special Report for the Bypass of the Offgas Treatment Storage System L-MT-22-008, 10 CFR 50.55a Request Associated with the Monticello Sixth Inservice Testing Ten-Year Interval Alternative Related to Excess Flow Check Valve Testing Frequency (L-MT-22-008)2022-03-0707 March 2022 10 CFR 50.55a Request Associated with the Monticello Sixth Inservice Testing Ten-Year Interval Alternative Related to Excess Flow Check Valve Testing Frequency (L-MT-22-008) L-MT-22-006, 10 CFR 50.55a Request Associated with the Monticello Sixth Inservice Testing Ten-Year Interval OMN-26 (L-MT-22-006)2022-02-18018 February 2022 10 CFR 50.55a Request Associated with the Monticello Sixth Inservice Testing Ten-Year Interval OMN-26 (L-MT-22-006) 2024-01-11
[Table view] |
Text
Xcel Energy Monticello Nuclear Generating Plant 2807 W County Road 75 Monticello, MN 55362 December 27, 2013 L-MT-13-116 10 CFR 50.46(a)(3)(ii)
U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 Monticello Nuclear Generating Plant Docket 50-263 Renewed Facility Operating License No. DPR-22 2013 Annual Report of Changes and Errors in Emergency Core Cooling System Evaluation Models
References:
- 1) NSPM to NRC letter, "2012 Report of Changes and Errors in Emergency Core Cooling System Evaluation Models," (L-MT-12-099),
dated December 20, 2012
- 2) NRC to NSPM, "
Subject:
Monticello Nuclear Generating Plant-Issuance of Amendment No. 176 to Renewed Facility Operating License Regarding Extended Power Uprate (TAC No. MD9990)," dated December 9, 2013.
- 3) GE Report, NEDC-32514P, Revision 1, "Monticello SAFER/GESTR LOCA Loss of Coolant Accident Analysis," dated October 1997
- 4) GE Report, GE-NE-J1103878-09-02P, "Monticello ECCS-LOCA Evaluation for GE14," dated August 2001
- 5) GE Notification Letter 2012-01, Revision 1, "PRIME Fuel Properties Implementation for Fuel Rod T/M Performance, replacing GESTR Fuel Properties," dated July 30, 2013
- 6) NSPM to NRC letter, "August 2013, 10 CFR 50.46 Thirty-Day Report,"
(L-MT-13-090), dated August 27, 2013 Pursuant to 10 CFR 50.46(a)(3)(ii), the Northern States Power Company, a Minnesota corporation (NSPM), doing business as Xcel Energy, is providing the annual report of changes or errors identified in the Emergency Core Cooling System (ECCS) evaluation model for the Monticello Nuclear Generating Plant (MNGP). This report is for the period since the last annual update (Reference 1), i.e., between July 2012 and July 2013.
Document Control Desk L-MT-13-116 Page 2 of 3 An Extended Power Uprate (EPU) amendment (Amendment 176) was issued December 9, 2013 (Reference 2), but the changes related to this amendment are not included herein because they did not occur during the reporting period. A separate 10 CFR 50.46 report discussing changes and errors in EPU ECCS evaluation models is under development and is to be submitted to re-baseline this annual report with the adoption of EPU.
The MNGP Loss of Coolant Accident (LOCA) analyses of record (AORs), for the reporting period, are contained in General Electric (GE) reports performed for the MNGP rerate to the previous licensed thermal power (1775 MWt) (Reference 3) and the LOCA analysis for the GE14 fuel type comprising the MNGP core (Reference 4). These analyses were adjusted for the estimated effect of errors or changes subsequently discovered in the evaluation models or in their application.
During this reporting period, a notification of an error or change resulting in a change to the Peak Cladding Temperature (PCT) was received from General Electric Hitachi (GEH) Nuclear Energy. GEH Notification Letter 2012-01, Revision1 (Reference 5),
reflects a reduction in the change in PCT from 45°F to 10°F, when applying the PRIME fuel properties model for fuel rod thermal I mechanical (T I M) performance, which replaced the GESTR fuel properties model. This resulted in an Adjusted PCT of 2050°F. The modeling change still, however, resulted in a cumulative increase in PCT exceeding the 50°F threshold specified in 10 CFR 50.46, and was reported in a 30-day report on August 27, 2013 (Reference 6).
As prescribed by 10 CFR 50.46, a proposed reanalysis schedule or an evaluation is required to demonstrate the facility remains in compliance with the requirements of the regulation when the cumulative increase in PCT threshold is exceeded. With the adoption of the EPU amendment this reanalysis has been completed. No further reanalysis or other actions are planned.
The enclosure provides additional information on the nature of the change, and the previous changes and errors, and their effect on the prior MNGP LOCA analysis. This information is being submitted in accordance with the requirements of 10 CFR 50.46(a)(3)(ii) for the MNGP.
Document Control Desk L-MT-13-116 Page 3 of 3 If you have any questions or require additional information, please contact Mr. Richard Loeffler at (763) 295-1247.
Summary of Commitments This letter proposes no new commitments and does not revise any existing commitments.
Karen D. Fili, Site Vice-President, Monticello Nuclear Generating Plant Northern States Power Company- Minnesota Enclosure cc: Regional Administrator, Region Ill, USNRC Project Manager, Monticello Nuclear Generating Plant, USNRC Resident Inspector, Monticello Nuclear Generating Plant, USNRC
ENCLOSURE MONTICELLO NUCLEAR GENERATING PLANT TABLE 1 -
SUMMARY
OF MONTICELLO LOCA CHANGES AND ERRORS INVOLVING CHANGES IN PEAK CLADDING TEMPERATURE (PCT)
(3 Pages Follow)
L-MT-13-116 Enclosure Page 1 of 3 Table 1 -Summary of Monticello LOCA Changes and Errors Involving Changes in Peak Cladding Temperature Licensing Applicable Analysis or Error Description Ref. Basis PCT(°F)
GE14 NEDC-32514P, Revision 1, Monticello SAFER/GESTR-LOCA 1 ----
Loss of Coolant Accident Analysis GE-NE-J1103878-09-02P, Monticello ECCS-LOCA 2 < 1960 Evaluation for GE 14 Impact of SAFER LeveiNolume Table Error on [Peak Cladding Temperature] PCT (Notification Letter 2003-01) 3 - 15 Level and volume tables used by SAFER were not updated when a revised initial water level was implemented.
Impact of Top Peaked Power Shape for Small Break LOCA Analysis (Notification Letter 2006-01)
Small Break LOCA analyses had assumed a mid-peaked axial 4 + 30 power shape consistent with the DBA break analyses. It was determined that a top-peaked axial power shape can result in higher calculated PCT.
Impact of database error for heat deposition on the Peak Cladding Temperature (PCT) for 10x10 fuel bundles (Notification Letter 2011-02)
The input coefficients used to direct the deposition of gamma 5 + 60 radiation energy produced by the fuel caused the heat deposited in the fuel channel (post scram) to be over-predicted and the corresponding heat in the fuel to be under-predicted.
(continued)
L-MT-1 3-116 Enclosure Page 2 of 3 Licensing Basis Applicable Analysis or Error Description Ref.
PCT(°F)
GE14 Impact of updated formulation for gamma heat deposition to channel wall for 9x9 and 1Ox1 0 fuel bundles (Notification Letter 2011-03)
In the input formulation for SAFER, the method for the contribution of heat from gamma ray absorption by the channel had been simplified so that initially all energy was deposited in 6 +5 the fuel rods prior to the LOCA and then adjusted to the correct heat deposition after the scram. Not accounting for this small fraction of power generation outside the fuel rod tends to suppress the hot bundle power required to meet the initial operating Peak LHGR. Also, there is a small effect on the initial conditions for the rest of the core as these are set in relation to the hot bundle condition.
PRIME Fuel Properties Implementation for Fuel Rod T/M Performance, replacing GESTR Fuel Properties (Notification Letter 2012-01, Revision 1)
This change is due to the application of an NRC-approved 7 + 10 procedure to estimate the change in PCT due to the change in fuel properties from GESTR to PRIME primarily to address inaccuracies in fuel pellet thermal conductivity as a function of exposure.
Sum of absolute value of changes during the current reporting period. 10 Sum of absolute value of changes since last AOR. 120 Algebraic sum of changes during the current reporting period. + 10 Algebraic sum of changes since last A OR. + 90 Current Adjusted Peak Cladding Temperature < 2050
L-MT-13-116 Enclosure Page 3 of 3 References
- 1. GE Report: NEDC-32514P, Revision 1, "Monticello SAFER/GESTR-LOCA Loss-of-Coolant Accident Analysis," dated October 1997.
- 2. GE-NE-J11 03878-09-02P, "Monticello ECCS-LOCA Evaluation for GE14,"
dated August 2001.
- 3. 10 CFR 50.46 Notification Letter 2003-01, "Impact of SAFER LeveiNolume Table Error on the Peak Cladding Temperature (PCT)," dated May 6, 2003.
- 4. 10 CFR 50.46 Notification Letter 2006-01, "Impact of Top Peaked Power Shape for Small Break LOCA Analysis," dated July 28, 2006.
- 5. 10 CFR 50.46 Notification Letter 2011-02, "Impact of database error for heat deposition on the Peak Cladding Temperature (PCT) for 1Ox1 0 fuel bundles," dated June10,2011.
- 6. 10 CFR 50.46 Notification Letter 2011-03, "Impact of updated formulation for gamma heat deposition to channel wall for 9x9 and 1Ox1 0 fuel bundles," dated June 10, 2011.
- 7. 10 CFR 50.46 Notification Letter 2012-01, Revision 1, "PRIME Fuel Properties Implementation for Fuel Rod TIM Performance, replacing GESTR Fuel Properties,"
dated July 30, 2013.