MONTHYEARML13196A0792013-07-16016 July 2013 Request for Additional Information Regarding Overall Integrated Plan for Reliable Spent Fuel Pool Instrumentation Project stage: RAI 1CAN091301, Updated Seismic Walkdown Report2013-09-30030 September 2013 Updated Seismic Walkdown Report Project stage: Request 2CAN091302, Updated Seismic Walkdown Report2013-09-30030 September 2013 Updated Seismic Walkdown Report Project stage: Request ML13336A7842013-11-26026 November 2013 Response to Request for Additional Information (RAI) Pursuent to 10 CFR 50.54(f) Regarding the Seismic Hazard Walkdowns Conducted to Verify Current Plant Compliance with the Current Licensing Basis (CLB) for Seismic Requirements Project stage: Response to RAI ML14055A0452014-01-22022 January 2014 Response to Request for Additional Information Re License Amendment Request on Revising Section 3.6.5 of the Technical Specifications, Containment Air Temperature. Project stage: Response to RAI ML14079A5222014-03-14014 March 2014 Response to Request for Additional Information Regarding License Amendment Request on Revising Section 3.6.5 of the Technical Specifications, Containment Air Temperature Project stage: Response to RAI ML14051A1882014-03-18018 March 2014 Staff Assessments of the Seismic Walkdown Report Supporting Implementation of Near-Term Task Force Recommendation 2.3 Related to Fukushima Dai-Ichi Nuclear Power Plant Accident (TAC MF0090-MF0091) Project stage: Other ML14093A0312014-03-26026 March 2014 Response to Request for Additional Information Regarding License Amendment Request on Revising Section 3.6.5 of the Technical Specifications, Containment Air Temperature Project stage: Response to RAI ML14167A0102014-06-0606 June 2014 Response to Request for Additional Information Regarding License Amendment Request on Revising Section 3.6.5 of the Technical Specifications, Containment Air Temperature Project stage: Response to RAI ML14232A3312014-08-21021 August 2014 Non-Proprietary, Correction to Amendment No. 116 Issued August 12, 2014, Revision to Technical Specification Section 3.6.5, 'Containment Air Temperature Project stage: Acceptance Review L-2015-291, Final Compliance with EA-12-051 Order Modifying Licenses with Regard to Reliable Spent Fuel Pool Instrumentation2015-12-10010 December 2015 Final Compliance with EA-12-051 Order Modifying Licenses with Regard to Reliable Spent Fuel Pool Instrumentation Project stage: Other 2014-03-14
[Table View] |
|
---|
Category:Letter type:L
MONTHYEARL-2024-010, Point Units 3 and 4, Seabrook, Duane Arnold, and Point Beach Units 1 and 2, Nuclear Property Insurance - 10 CFR 50.54(w)(3)2024-01-25025 January 2024 Point Units 3 and 4, Seabrook, Duane Arnold, and Point Beach Units 1 and 2, Nuclear Property Insurance - 10 CFR 50.54(w)(3) L-2024-004, Relief Request (RR) 7, Proposed Alternative in Accordance with 10 CFR 50.55a(z)(1) Extension of Inspection Interval for Reactor Pressure Vessel Welds from 10 to 20 Years2024-01-18018 January 2024 Relief Request (RR) 7, Proposed Alternative in Accordance with 10 CFR 50.55a(z)(1) Extension of Inspection Interval for Reactor Pressure Vessel Welds from 10 to 20 Years L-2024-002, Withdrawal of Proposed Alternative to American Society of Mechanical Engineers (ASME) Operation and Maintenance (OM) Code for the Auxiliary Feedwater (AFW) 2C Pump2024-01-0808 January 2024 Withdrawal of Proposed Alternative to American Society of Mechanical Engineers (ASME) Operation and Maintenance (OM) Code for the Auxiliary Feedwater (AFW) 2C Pump L-2023-173, Quality Assurance Topical Report (FPL-1) Revision 30 Update2023-12-15015 December 2023 Quality Assurance Topical Report (FPL-1) Revision 30 Update L-2023-179, Unusual or Important Environmental Event - Turtle Mortality2023-12-14014 December 2023 Unusual or Important Environmental Event - Turtle Mortality L-2023-168, License Amendment Request Supplement to Revision 2 for the Technical Specifications Conversion to NUREG-1432 Revision 52023-12-12012 December 2023 License Amendment Request Supplement to Revision 2 for the Technical Specifications Conversion to NUREG-1432 Revision 5 L-2023-155, Supplement to Response to Request for Additional Information, Revised NextEra Common Emergency Plan, and Revised Site-Specific Emergency Plan Annexes Regarding License Amendment Request for Common Emergency Plan Consistent with NUREG-06542023-11-28028 November 2023 Supplement to Response to Request for Additional Information, Revised NextEra Common Emergency Plan, and Revised Site-Specific Emergency Plan Annexes Regarding License Amendment Request for Common Emergency Plan Consistent with NUREG-0654, L-2023-162, Response to 50.69 2nd Round of Rals2023-11-21021 November 2023 Response to 50.69 2nd Round of Rals L-2023-131, Subsequent License Renewal Application - Second Annual Update2023-09-28028 September 2023 Subsequent License Renewal Application - Second Annual Update L-2023-136, Supplement to License Amendment Request to Adopt 10 CFR 50.69, Risk-Informed Categorization and Treatment of Structures, Systems and Components for Nuclear Power Reactors2023-09-26026 September 2023 Supplement to License Amendment Request to Adopt 10 CFR 50.69, Risk-Informed Categorization and Treatment of Structures, Systems and Components for Nuclear Power Reactors L-2023-122, Corrections to the 2022 Annual Radiological Environmental Operating Report2023-09-20020 September 2023 Corrections to the 2022 Annual Radiological Environmental Operating Report L-2023-127, Correction to the 2022 Annual Radioactive Effluent Release Report2023-09-18018 September 2023 Correction to the 2022 Annual Radioactive Effluent Release Report L-2023-113, Correction to the 2020 Annual Radiological Environmental Operating Report2023-09-14014 September 2023 Correction to the 2020 Annual Radiological Environmental Operating Report L-2023-118, Response to Request for Additional Information Regarding License Amendment Request to Adopt 10 CFR 50.69, Risk-Informed Categorization and Treatment of Structures, Systems and Components for Nuclear Power Reactors2023-09-11011 September 2023 Response to Request for Additional Information Regarding License Amendment Request to Adopt 10 CFR 50.69, Risk-Informed Categorization and Treatment of Structures, Systems and Components for Nuclear Power Reactors L-2023-108, Report of 10 CFR 50.59 Plant Changes2023-09-11011 September 2023 Report of 10 CFR 50.59 Plant Changes L-2023-112, Corrections to the 2021 Annual Radioactive Effluent Release Report2023-09-0606 September 2023 Corrections to the 2021 Annual Radioactive Effluent Release Report L-2023-107, Technical Specification Bases Control Program Periodic Report of Bases Changes TS 6.8.4.j.42023-09-0606 September 2023 Technical Specification Bases Control Program Periodic Report of Bases Changes TS 6.8.4.j.4 L-2023-114, Proposed Turkey Point Units 6 and 7; Seabrook Station; Point Beach Units 1 and 2 - Official Service List Update2023-08-17017 August 2023 Proposed Turkey Point Units 6 and 7; Seabrook Station; Point Beach Units 1 and 2 - Official Service List Update L-2023-098, and Point Beach Units 1 and 2 - Response to Request for Additional Information Regarding License Amendment Request for Common Emergency Plan Consistent with NUREG-0654, Revision 22023-08-0707 August 2023 and Point Beach Units 1 and 2 - Response to Request for Additional Information Regarding License Amendment Request for Common Emergency Plan Consistent with NUREG-0654, Revision 2 L-2023-105, Preparation and Scheduling of Operator Licensing Examinations2023-08-0303 August 2023 Preparation and Scheduling of Operator Licensing Examinations L-2023-099, Pump Relief Request 10 (PR-10), One-Time Request for an Alternative to the American Society of Mechanical Engineers (ASME) Operation and Maintenance (OM) Code for the Auxiliary Feedwater (AFW) 2C Pump2023-07-26026 July 2023 Pump Relief Request 10 (PR-10), One-Time Request for an Alternative to the American Society of Mechanical Engineers (ASME) Operation and Maintenance (OM) Code for the Auxiliary Feedwater (AFW) 2C Pump L-2023-102, Relief Request PSL2-15-RR-01, Proposed Alternative to ASME Section XI Code Examination Requirements for Reactor Vessel Bottom Area and Piping in Covered Trenches2023-07-26026 July 2023 Relief Request PSL2-15-RR-01, Proposed Alternative to ASME Section XI Code Examination Requirements for Reactor Vessel Bottom Area and Piping in Covered Trenches L-2023-097, Subsequent License Renewal Application Revision 1 - Supplement 62023-07-13013 July 2023 Subsequent License Renewal Application Revision 1 - Supplement 6 L-2023-076, In-Service Inspection Program Owner'S Activity Report (OAR-1)2023-07-11011 July 2023 In-Service Inspection Program Owner'S Activity Report (OAR-1) L-2023-087, Florida Power & Light/Nextera Energy, Results of the Safety Culture Program Effectiveness Review, March 20, 2023 (ADAMS Accession No. ML22340A452)2023-06-29029 June 2023 Florida Power & Light/Nextera Energy, Results of the Safety Culture Program Effectiveness Review, March 20, 2023 (ADAMS Accession No. ML22340A452) L-2023-082, Subsequent License Renewal Application Revision 1, Supplement 52023-06-14014 June 2023 Subsequent License Renewal Application Revision 1, Supplement 5 L-2023-074, Addendum to 2021 Decommissioning Funding Status Reports / Independent Spent Fuel Storage Installation Ctsfsi) Financial Assurance Update2023-06-0202 June 2023 Addendum to 2021 Decommissioning Funding Status Reports / Independent Spent Fuel Storage Installation Ctsfsi) Financial Assurance Update L-2023-071, NextEra Energy Quality Assurance Topical Report (FPL-1) Revision 29 and Florida Power and Light Company Quality Assurance Program Description for 10 CFR Part 52 Licenses (FPL-2) Revision 11, Annual Submittal2023-05-22022 May 2023 NextEra Energy Quality Assurance Topical Report (FPL-1) Revision 29 and Florida Power and Light Company Quality Assurance Program Description for 10 CFR Part 52 Licenses (FPL-2) Revision 11, Annual Submittal L-2023-059, Subsequent License Renewal Application - Aging Management Requests for Additional Information (RAI) Set 4 Supplemental Response2023-04-21021 April 2023 Subsequent License Renewal Application - Aging Management Requests for Additional Information (RAI) Set 4 Supplemental Response L-2023-055, 2022 Annual Environmental Operating Report2023-04-12012 April 2023 2022 Annual Environmental Operating Report L-2023-041, Annual Radiological Environmental Operating Report for Calendar Year 20222023-04-0404 April 2023 Annual Radiological Environmental Operating Report for Calendar Year 2022 L-2023-051, Report of 10 CFR 50.59 Plant Changes2023-04-0404 April 2023 Report of 10 CFR 50.59 Plant Changes L-2023-021, Units, 1 and 2, Turkey Point, Units 3 and 4, Seabrook Station and Point Beach, Units 1 and 2 - Decommissioning Funding Status Reports / Independent Spent Fuel Storage Installation (ISFSI) Financial Assurance Update2023-03-28028 March 2023 Units, 1 and 2, Turkey Point, Units 3 and 4, Seabrook Station and Point Beach, Units 1 and 2 - Decommissioning Funding Status Reports / Independent Spent Fuel Storage Installation (ISFSI) Financial Assurance Update L-2023-042, Periodic Update of Population Data within 10 and 50 Miles of the Plant2023-03-27027 March 2023 Periodic Update of Population Data within 10 and 50 Miles of the Plant L-2023-026, Subsequent License Renewal Application - Aging Management Requests for Additional Information Set 42023-03-27027 March 2023 Subsequent License Renewal Application - Aging Management Requests for Additional Information Set 4 L-2023-028, and Point Beach Units 1 and 2, 10 CFR 50.46 Annual Reporting of Changes to, or Errors in Emergency Core Cooling System Models or Applications2023-03-27027 March 2023 and Point Beach Units 1 and 2, 10 CFR 50.46 Annual Reporting of Changes to, or Errors in Emergency Core Cooling System Models or Applications L-2023-025, Fleet Relief Request (Frr) 23-01, Proposed Alternative to ASME Section XI Authorizing Implementation of ASME Code Case N-752-12023-03-15015 March 2023 Fleet Relief Request (Frr) 23-01, Proposed Alternative to ASME Section XI Authorizing Implementation of ASME Code Case N-752-1 L-2023-029, and Point Beach Units 1 and 2 Nuclear Property Insurance - 10 CFR 50.54(w)(3)2023-03-10010 March 2023 and Point Beach Units 1 and 2 Nuclear Property Insurance - 10 CFR 50.54(w)(3) L-2023-039, Cycle 27 Core Operating Limits Report2023-03-0707 March 2023 Cycle 27 Core Operating Limits Report L-2023-032, 2022 Annual Radioactive Effluent Release Report2023-02-28028 February 2023 2022 Annual Radioactive Effluent Release Report L-2023-038, 2022 Annual Operating Report2023-02-28028 February 2023 2022 Annual Operating Report L-2023-016, Radiological Emergency Plan - Revision 74 Report of Changes to Emergency Plan2023-02-15015 February 2023 Radiological Emergency Plan - Revision 74 Report of Changes to Emergency Plan L-2023-019, Annual Summary of Commitment Changes Implemented Without Prior NRC Notification for Calendar Year 20222023-02-15015 February 2023 Annual Summary of Commitment Changes Implemented Without Prior NRC Notification for Calendar Year 2022 L-2023-009, Owner'S Activity Report2023-01-31031 January 2023 Owner'S Activity Report L-2022-188, Unusual or Important Environmental Event - Turtle Mortality2022-12-19019 December 2022 Unusual or Important Environmental Event - Turtle Mortality L-2022-185, Turkey Points, Units 3 & 4; Seabrook Station; and Point Beach, Units 1 and 2 - Supplement to License Amendment Request for Common Emergency Plan Consistent with NUREG-0654, Revision 22022-12-0909 December 2022 Turkey Points, Units 3 & 4; Seabrook Station; and Point Beach, Units 1 and 2 - Supplement to License Amendment Request for Common Emergency Plan Consistent with NUREG-0654, Revision 2 L-2022-175, Application to Adopt 10 CPR 50.69, 'Risk-Informed Categorization and Treatment of Structures, Systems and Components for Nuclear Power Reactors2022-12-0202 December 2022 Application to Adopt 10 CPR 50.69, 'Risk-Informed Categorization and Treatment of Structures, Systems and Components for Nuclear Power Reactors L-2022-180, CFR 140.21 Licensee Guarantees of Payment of Deferred Premiums2022-11-0909 November 2022 CFR 140.21 Licensee Guarantees of Payment of Deferred Premiums L-2022-165, Subsequent License Renewal Application - Aging Management Request for Additional Information (RAI) 4.3.1-1a(second Round) - Class 1 Fatigue Response2022-10-26026 October 2022 Subsequent License Renewal Application - Aging Management Request for Additional Information (RAI) 4.3.1-1a(second Round) - Class 1 Fatigue Response L-2022-160, Station,, Point Beach Units 1 and 2, License Amendment Request for Common Emergency Plan Consistent with NUREG-0654, Revision 22022-10-0404 October 2022 Station,, Point Beach Units 1 and 2, License Amendment Request for Common Emergency Plan Consistent with NUREG-0654, Revision 2 2024-01-08
[Table view] Category:Status Report
MONTHYEARL-2019-046, Stations - Decommissioning Funding Status Reports / Independent Spent Fuel Storage Installation (ISFSI) Financial Assurance Update2019-03-25025 March 2019 Stations - Decommissioning Funding Status Reports / Independent Spent Fuel Storage Installation (ISFSI) Financial Assurance Update L-2017-040, Decommissioning Funding Status Reports/Independent Spent Fuel Storage Installation (ISFSI) Financial Assurance Update2017-03-30030 March 2017 Decommissioning Funding Status Reports/Independent Spent Fuel Storage Installation (ISFSI) Financial Assurance Update L-2015-297, Status of Required Actions for EA-12-049 Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events, and Submittal of Site FLEX Final Integrated Plan2015-12-10010 December 2015 Status of Required Actions for EA-12-049 Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events, and Submittal of Site FLEX Final Integrated Plan L-2015-291, Final Compliance with EA-12-051 Order Modifying Licenses with Regard to Reliable Spent Fuel Pool Instrumentation2015-12-10010 December 2015 Final Compliance with EA-12-051 Order Modifying Licenses with Regard to Reliable Spent Fuel Pool Instrumentation L-2015-215, Fifth Overall Integrated Plan Status Report in Response to March 12, 2012 Commission Order Modifying Licenses with Regard with to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events (Order EA-12-049)2015-08-20020 August 2015 Fifth Overall Integrated Plan Status Report in Response to March 12, 2012 Commission Order Modifying Licenses with Regard with to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events (Order EA-12-049) ML14064A1932014-02-28028 February 2014 Second Six Month Status Report in Response to March 12, 2012 Commission Order to Modify Licenses with Regard to Reliable Spent Fuel Pool Instrumentation (Order Number EA-12-051) L-2013-254, First Overall Integrated Plan Status Report in Response to March 12, 2012 Commission Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events (Order Number EA-12-049)2013-08-28028 August 2013 First Overall Integrated Plan Status Report in Response to March 12, 2012 Commission Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events (Order Number EA-12-049) L-2013-253, St. Lucie'S First Six-Month Status Report to the Overall Integrated Plan in Response to March 12, 2012 Commission Order to Modify Licenses2013-08-27027 August 2013 St. Lucie'S First Six-Month Status Report to the Overall Integrated Plan in Response to March 12, 2012 Commission Order to Modify Licenses L-2013-103, Decommissioning Funding Status Reports2013-03-25025 March 2013 Decommissioning Funding Status Reports ML1214500142012-05-23023 May 2012 NFPA 805 LAR Status Matrix - May 2012 ML12024A3762011-12-28028 December 2011 State-of-the-Art Reactor Consequence Analyses, Current Status and Next Steps L-2009-055, Units 1 and 2, Decommissioning Funding Status Reports2009-03-27027 March 2009 Units 1 and 2, Decommissioning Funding Status Reports L-2008-018, Transmittal of Pressurized Butt Weld Alloy Report, and Mitigation Status and Swol Inspection Results2008-02-21021 February 2008 Transmittal of Pressurized Butt Weld Alloy Report, and Mitigation Status and Swol Inspection Results ML0709305552007-03-29029 March 2007 Decommissioning Fund Status Report ML0609601312006-03-27027 March 2006 Decommissioning Fund Status Report ML0418903072004-04-18018 April 2004 Event Notification Report for April 18, 2000 ML0313206902003-02-12012 February 2003 Daily Status Report for 02/12/2003 ML0313206892003-02-0303 February 2003 Daily Status Report for 02/03/2003 ML0313206872003-01-23023 January 2003 Daily Status Report for 01/23/2003 ML0313206832003-01-0202 January 2003 Daily Status Report for 01/02/2003 ML0313206822002-12-17017 December 2002 Daily Status Report for 12/17/2002 ML0313206802002-11-22022 November 2002 Daily Status Report for 11/22/2002 ML0313205062002-10-22022 October 2002 Daily Status Report for 10/22/2002 ML0313205042002-10-20020 October 2002 Daily Status Report for 10/20/2002 ML0313205012002-09-19019 September 2002 Daily Status Report for 09/19/2002 ML0313207362002-06-0202 June 2002 Daily Status Report for 06/02/2002 ML0313207332002-05-29029 May 2002 Daily Status Report for 05/29/2002 ML0224007812002-01-18018 January 2002 E-mail from Jacob Zimmerman, Bulletin 2001-01 Status Report L-76-361, Forwards Reactor Vessel Overpressurization Issue Progress Report1976-10-18018 October 1976 Forwards Reactor Vessel Overpressurization Issue Progress Report 2019-03-25
[Table view] |
Text
0December FPLI~.. 10, 2015 L- 2015-291 10 CFR 2.202 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 RE: St. Lucie Unit 2 Docket 50-3 89 Florida Power & Light/St. Lucie Unit 2 Final Compliance with EA-12-051 Order Modifying Licenses with Regard to Reliable Spent Fuel Pool Instrumentation
References:
- 1. U.S. Nuclear Regulatory Commission, Order Number BA- 12-051, Order Modifying Licenses with Regard to Reliable Spent Fuel Pool Instrumentation (Effective Immediately),
dated March 12, 2012, Accession No. ML12056A044.
- 2. U.S. Nuclear Regulatory Commission, Interim Staff Guidance JLD-ISG-2012-03, Compliance with Order BA- 12-051, Reliable Spent Fuel Pool Instrumentation, Revision 0, dated August 29, 2012, Accession No. ML12221A339.
- 3. NEI 12-02, Revision 1, Industry Guidance for Compliance with NRC Order EA-12-051, To Modify Licenses with Regard to Reliable Spent Fuel Pool Instrumentation, dated August, 2012, Accession No. ML12240A307.
- 4. FPL Letter L-2012-384, dated October 25, 2012, Florida Power & Light (FPL)'s Initial Status Report in Response to March 12, 2012 Commission Order Modifying Licenses with Regard to Requirements for Reliable Spent Fuel Pool Instrumentation (Order Number BA- 12-051), Accession No. ML12300A420.
- 5. FPL Letter L-2013-079, dated February 28, 2013, Florida Power & Light/St. Lucie' s Overall Integrated Plan in Response to March 12, 2012 Commission Order to Modify Licenses with Regard to Reliable Spent Fuel Pool Instrumentation (Order Number EA 051), Accession No. ML13063A026.
- 6. NRC Letter to Florida Power & Light St. Lucie Nuclear Plant, Units 1 and 2 - Request for Additional Information Regarding Overall Integrated Plan for Reliable SFP Instrumentation (Order No. EA-12-051) (TAC Nos. MF00090 and MF0091), dated July 16, 2013, Accession Number ML13196A079.
- 7. FPL Letter L-2013-223, dated July 26, 2013, Florida Power & Light/St. Lucie's Response to Request for Additional Information Regarding Overall Integrated Plan in Response to Order EA-12-051, "Reliable Spent Fuel Pool Instrumentation," Accession No. ML13219A838.
- 8. FPL Letter L-2013-253, dated August 27, 2013, Florida Power & Light/St. Lucie's first Six-Month Status Report to the Overall Integrated plan in Response to March 12, 2012 Commission Order to Modify Licenses with Regard to reliable Spent fuel Pool Instrumentation (Order Number BA- 12-051), Accession No.ML13242A006.
- 9. NRC Letter to Florida Power & Light St. Lucie Nuclear Plant, Units 1 and 2 - Interim Staff Evaluation and Request for Additional Information Regarding the Overall Integrated Plan Florida Power & Light Company
- O 6501 S. Ocean Drive, Jensen Beach, FL 34957 I .I
L-2015-291 Page 2 for Implementation of Order EA- 12-051, Reliable Spent Fuel Pool Instrumentation (TAC Nos. MF0990 and MF0991) dated November 19, 2013, Accession No. ML13274A473.
- 10. FPL Letter L-2013-061, dated February 28, 2014, Florida Power & Light/St. Lucie' s Second Six-Month Status Report to the Overall Integrated plan in Response to March 12, 2012 Commission Order to Modify Licenses with Regard to reliable Spent fuel Pool Instrumentation (Order Number EA- 12-05 1), Accession No. 14064A193.
- 11. FPL Letter L-20 14-275 dated August 27, 2014, Florida Power & Light!St. Lucie Third Six Month Status Report in Response to March 12, 2012 Commission Order to Modify Licenses with Regard to Reliable Spent Fuel Pool Instrumentation (Order Number EA 051), Accession No. ML14253A185.
- 12. FPL Letter L-2015-054 dated February 23, 2015, Florida Power & Light/St. Lucie Fourth Six Month Status Report in Response to March 12, 2012 Commission Order to Modify Licenses with Regard to Reliable Spent Fuel Pool Instrumentation (Order Number EA 051), Accession No. ML15071A265.
- 13. FPL Letter L-2015-l115 dated May 12, 2015, Florida Power & Light/St. Lucie Unit 1 Final Compliance with BA- 12-051 Order Modifying Licenses with Regard to Reliable Spent Fuel Pool Instrumentation, Accession No. ML15140A393.
- 14. FPL Letter L-2015-214 dated August 25, 2015, Florida Power & Light/St. Lucie Fifth Six Month Status Report in Response to March 12, 2012 Commission Order to Modify Licenses with Regard to Reliable Spent Fuel Pool Instrumentation (Order Number EA 051), Accession No. ML15246A143.
- 15. NRC letter to All Operating Reactor Licensees and Holders of Construction Permits, "Nuclear Regulatory Commission Audits of Licensee Responses to Mitigation Strategies Order EA-12-049," dated August 28, 2013, Accession No. ML13234A503.
- 16. NRC Letter dated February 27, 2015, St. Lucie Plant, Units 1 and 2, Report for the Onsite Audit Regarding Implementation of Mitigating Strategies and Reliable Spent Fuel Instrumentation Related to Orders EA-12-049 and EA-12-051 (TAC Nos. MF0984, MF0985, M1F0990, and MF0991), Accession No. ML15035A670.
On March 12, 2012, the Nuclear Regulatory Commission (NRC) issued an order (Reference 1) to FPL. Reference 1 was immediately effective and directs FPL to install reliable spent fuel pool level instrumentation. Specific requirements are outlined in Attachment 2 of Reference 1.
Reference 1 required submission of an initial status report 60 days following issuance of the final interim staff guidance (Reference 2) and an overall integrated plan pursuant to Section IV, Condition C. Reference 2 endorses industry guidance document NEI 12-02, Revision 1 (Reference 3) with clarifications and exceptions identified in Reference 2. Reference 4 provided the FPL initial status report regarding mitigation strategies. Reference 5 provided the FPL Overall Integrated Plan.
Reference 1 requires submission of a status report at six month intervals following submittal of the Overall Integrated Plan. Reference 3 provides direction regarding the content of the status reports. The first, second, third, fourth, and fifth six month status reports were submitted in Reference 8, 10, 11, 12, and 14.
UOI1~1U~UInI1SUJ lood ion~i Tu~dS ~1q~'1~N 01 ~ M!M sosu~q ~U14Jip0IN z pu~ ssIn mowi ~s 'bo1~dsuI 1u~p!s~a ~o!u~s DNNSH II ~~O!~)1 'IOW~1S1IIWIPV 1O~~1 J~INSfl :03 IAA)J/D)D TUOPISOIJ ~0 !A Olls 0ZU~1S0D )J Joqdo1suq~
'popuuqns XjinjioodSo~1
~ ~A M7,~c~UO P04U00X~L
- OOJJOO pu~ orui si ~uio~ioJ 0M1 wq~ A.inCiodjo Xij~uod lopun ar~joop j 7tLLL9I7 (U~L) W I ~U~JIM ~UISU03VJ UPUIZ1~N ~'¶ NN 1~1U03 os~ojd 'iiodoi 5141 ~UipJ~oJ s~oiis~nb *IW ONEI4 tLOA J~ S1U0IflThIII~IIO0 XI0WJfl~OI MOU ou sui~uoo ~io~o~ su~
OJOM sjuoui~iinb~i oournldwoo Otil M0~J0 AJ~UflflflS 0111 soplAoId 10)40J S141 01 1U0UnI3~1I~ 0111 ~ 1TUfl 010fl'J lS J0J J0pJQ 0141 tiIIM 0ou~ijduioo JJflJ UT Si pu~ i~o-~T-V~iJ0 s~tiouIo~inbo~ 0141 p010ld1U00 S~q idi rrnji UOIWOIJJ1OU s0piAoJd 'o1,~oj suu~ poAorqo~ ST iopio 0141 Jo S1u0u1011nb0.I 0141 tilIM oournjduxoo IJnJ U014M UOTSSIUIIflOD 0141 01 ~podoi 01 soosuoowi ~ ponnbo~i Jopwj otpjo vc UQIlIPUOD
£ 0~J T6~-~IO~-q
L-2015-291 Attachment Page 1 of 5 FLORIDA POWER & LIGHT/ST. LUCIE UNIT 2 Final Compliance Summary with EA-12-051 Order Modifying Licenses with Regard to Reliable Spent Fuel Pool Instrumentation
L-2015-291 Attachment Page 2 of 5 St. Lucie Plant, Unit 2 Order BA- 12-051 Compliance Requirements Summary BACKGROUND The St. Lucie Plant developed an Overall Integrated Plan (OIP) (Reference 5), documenting how the requirements for reliable spent fuel pooi level instrumentation (SFPLI) would be achieved, in response to Order BA- 12-051, "Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events," (Reference 1). The St. Lucie Plant Units 1 and 20OIP was submitted to the NRC on February 28, 2013 and was supplemented by Six-Month Status Reports (References 6, 7, 10, 11, and 15), in accordance with Order BA 051 (the Order). By letter dated November 19, 2013, the NRC provided its Interim Staff Evaluation and Request for Additional Information Regarding Order EA-12-051 (Reference 12).
Each St. Lucie unit is provided with a dedicated Spent Fuel Pool (SFP). St. Lucie Unit 2 had two independent SFP level measurement channels, supplied and qualified by Westinghouse, installed in response to Reference 1.
On October 25, 2015, St. Lucie Unit 2 achieved full compliance with Order BA-12-051 and commenced reactor startup. Completion of the elements identified below for St. Lucie Unit 2, as well as References 5, 6, 7, 10, 11, and 15 constitutes full compliance with Order EA-12-051 for St. Lucie Unit 2.
The design features for thle Unit 2 spent fuel pool level instrumentation are identified in Engineering Change BC 280520. This document has previously been provided to the NRC and is available for their review.
COMPLIANCE
SUMMARY
NRC RAI, ISE and Audit Items - Status: Complete During the audit process (Reference 13), Florida Power & Light's (FPL) provided responses for the following items for St. Lucie Unit 2:
- Request for Additional Information (RAI)
- Interim Staff Evaluation (ISE) Open Items
- Licensee Identified Open Items
- Safety Evaluation Review Items The "St. Lucie Plant, Units 1 and 2 - Report for the Onsite Audit Regarding Implementation of Mitigating Strategies and Reliable Spent Fuel Pool Instrumentation Related to Orders BA- 12-049
L-2015-291 Attachment Page 3 of 5 and EA-12-05 1," (Reference 14) delineated the items reviewed during the St. Lucie onsite audit.
Reference 14 identified no open audit item(s) related to SFPLI within the Safety Evaluation.
As requested by the NRC, FPL responses, or references to the source document for the responses, to the SFPLI RA~s were provided in the St. Lucie Unit 1 SFP Order final compliance letter (Reference 16). It is FPL's position that no further actions related to the SFPLI RAls are required.
Milestone Schedule Items - Status: Complete
[St. Lucie Unit 2 Milestone * .... Completion Status Submit OIP Complete Commence Engineering and Design Complete Complete Engineering and Design Complete Complete Procurement of SFP Instruments Complete Commence Installation of SEP Instruments Complete Level Measurement System Functional Complete Identification of Levels of Required Monitoring - Status: Complete St. Lucie Plant has identified the three required levels for monitoring spent fuel pool (SFP) level in compliance with Order BA- 12-051. These levels have been integrated into the site processes for monitoring level during events and responding to loss of SFP inventory.
Instrument Designed Features - Status: Complete The design of the SFP level measurement instrumentation system installed at St. Lucie Unit 2 complies with the requirements specified in Order EA-12-051 and described in NEI 12-02 "Industry Guidance for Compliance with NRC Order EA-12-05 1." The instrumentation system has been installed in accordance with the station design control process.
The instruments have been arranged to provide reasonable protection against missiles. The instruments have been mounted to retain design configuration during and following the maximum expected ground motion. The instruments will be reliable during expected environmental and radiological conditions when the SFP is at saturation for extended periods.
The instruments are independent of each other and have separate and diverse power supplies.
The instruments will maintain their designed accuracy following a power interruption and are designed to allow for routine testing and calibration. The instrument display is readily accessible during postulated events and allows for SFP level information to be promptly available to decision makers.
L-2015-291 Attachment Page 4 of 5 Program Features - Status: Complete Training of personnel performing maintenance functions including calibration and surveillance associated with the SFP level instrument channels at St. Lucie Unit 2 has been completed in accordance with an accepted training process as recommended in NEL 12-02, Section 4.1.
Operating and maintenance procedures for the St. Lucie Unit 2 SFP level instrument channels have been developed, and integrated with existing procedures. These procedures have been verified and are available for use in accordance with the site procedure control program. Site processes have been established to ensure the instruments are maintained at their design accuracy.
REFERENCES The following references support the St. Lucie Unit 2 SFPLI Compliance Summary:
- 1. U.S. Nuclear Regulatory Commission, Order Number EA- 12-051, Order Modifying Licenses with Regard to Reliable Spent Fuel Pool Instrumentation (Effective Immediately),
dated March 12, 2012, Accession No. ML12056A044.
- 2. U.S. Nuclear Regulatory Commission, Interim Staff Guidance JLD-ISG-2012-03, Compliance with Order BA- 12-051, Reliable Spent Fuel Pool Instrumentation, Revision 0, dated August 29, 2012, Accession No. ML12221A339.
- 3. NEI 12-02, Revision 1, Industry Guidance for Compliance with NRC Order BA- 12-051, To Modify Licenses with Regard to Reliable Spent Fuel Pool Instrumentation, dated August, 2012, Accession No. ML12240A307.
- 4. FPL Letter L-2012-384, dated October 25, 2012, Florida Power & Light (FPL)'s Initial Status Report in Response to March 12, 2012 Commission Order Modifying Licenses with Regard to Requirements for Reliable Spent Fuel Pool Instrumentation (Order Number BA-12-05 1), Accession No. ML12300A420.
- 5. FPL Letter L-2013-079, dated February 28, 2013, Florida Power & Light/St. Lucie' s Overall Integrated Plan in Response to March 12, 2012 Commission Order to Modify Licenses with Regard to Reliable Spent Fuel Pool Instrumentation (Order Number EA 05 1), Accession No. M1L13063A026.
- 6. FPL Letter L-2013-253, dated August 27, 2013, Florida Power & Light/St. Lucie's First Six-Month Status Report to the Overall Integrated plan in Response to March 12, 2012 Commission Order to Modify Licenses with Regard to reliable Spent fuel Pool Instrumentation (Order Number EA- 12-05 1), Accession No.ML13242A006.
- 7. FPL Letter L-2013-061, dated February 28, 2014, Florida Power & Light/St. Lucie's Second Six-Month Status Report to the Overall Integrated plan in Response to March 12, 2012 Commission Order to Modify Licenses with Regard to reliable Spent fuel Pool Instrumentation (Order Number EA- 12-051), Accession No. 14064A 193.
- 8. NRC Letter to Florida Power and Light St. Lucie Nuclear Plant, Units 1 and 2 Request for Additional Information Regarding Overall Integrated Plan for Reliable SFP Instrumentation (Order No. EA-12-051) (TAC Nos. MF00090 and M\F0091), dated July 16, 2013, Accession Number ML13196A079.
L-2015-291 Attachment Page 5 of 5
- 9. FPL Letter L-2013-223, dated July 26, 2013, Florida Power and Light St. Lucie's Response to Request for Additional Information Regarding Overall Integrated Plan in Response to Order EA-12-051, Reliable Spent Fuel Pool Instrumentation, Accession No. ML13219A838.
- 10. FIPL Letter L-2014-275 dated August 27, 2014, Florida Power & Light!St. Lucie Third Six Month Status Report in Response to March 12, 2012 Commission Order to Modify Licenses with Regard to Reliable Spent Fuel Pool Instrumentation (Order Number EA 051), Accession No. ML14253A185.
- 11. FPL Letter L-2015-054 dated February 23, 2015, Florida Power & Light/St. Lucie Fourth Six Month Status Report in Response to March 12, 2012 Commission Order to Modify Licenses with Regard to Reliable Spent Fuel Pool Instrumentation (Order Number EA 051), Accession No. ML15071A265.
- 12. NRC Letter to Florida Power & Light St. Lucie Nuclear Plant, Units 1 and 2 - Interim Staff Evaluation and Request for Additional Information Regarding the Overall Integrated Plan for Implementation of Order BA- 12-051, Reliable Spent Fuel Pool Instrumentation (TAC Nos. MF0990 and MF0991) dated November 19, 2013, Accession No. MvL13274A473.
- 13. NRC letter to All Operating Reactor Licensees and Holders of Construction Permits, Nuclear Regulatory Commission Audits of Licensee Responses to Mitigation Strategies Order EA-12-049, dated August 28, 2013, Accession No. ML13234A503.
- 14. NRC Letter dated February 27, 2015, St. Lucie Plant, Units 1 and 2, Report for the Onsite Audit Regarding Implementation of Mitigating Strategies and Reliable Spent Fuel Instrumentation Related to Orders EA- 12-049 and EA- 12-051 (TAC Nos. M1F0984, MF0985, MF0990, and MF099 1), Accession No. ML15035A670.
- 15. FPL Letter L-2015-214 dated August 25, 2015, Florida Power & Light/St. Lucie Fifth Six Month Status Report in Response to March 12, 2012 Commission Order to Modify Licenses with Regard to Reliable Spent Fuel Pool Instrumentation (Order Number EA 05 1), Accession No. ML15246A143.
- 16. FPL Letter L-2015-1 15, dated May 12, 2015, Florida Power & Light/St. Lucie Unit 1 Final Compliance with EA-12-051 Order Modifying Licenses with Regard to Reliable Spent Fuel Pool Instrumentation, Accession No. ML15140A393.