3 Operations Department Chronological Log Unit 2 30-May-02 6422 529/2002 DAY DAVE GLISSON LARRY HARTLEe BILL CASIAS TIM SOLANDER CHARLIE PIKE NUC POWER:
94 DELTA T POWER:
94 MWE:
820 CEA GROUP :
5 POSITION:
125 T AVG:
572 BORON:
783 Xe WORTH:
-2543 MODE:
1 CALCULATED SD MARGIN: >3600 MAJOR MILESTONES OR ACTIVITIES TO BE PERFORMED DURING THE SHIFT:
25 GALS ACID OR 16 GALS OF H20 TO CHANGE RCS.1 DEGREES. BR 6.5 TO 1. COMPLETE TURBINE VALVE TE.
AND RETURN UNIT TO 100% POWER.
TIME LOG ENTRIES 6:45 CONDUCTED A BOARD WALKDOWN, TURNOVER, AND ASSUMED THE SHIFT.
8.55 I&C PERFORMING CONTROL ROOM OUTSIDE AIR INTAKE MONTHLY FUNCTIONAL AW 2-IMP-26.33.
WORKING ONE TRAIN AT A TIME BEGINNING WITH THE "A TRAIN. DECLARING A TRAIN OOS.
10:08 I&C FINISHED WITH THE "A TRAIN CROAI RAD MONITORS. DECLARED BIS. DECLARING B' TRAIN 00:
THIS TIME.
11:30 COMPLETED BRIEF FOR COMMENCING WITH THE TURBINE VALVE TEST.
11 38
.COMMENCING WITH TJRBINE VALVE TEST IAW 2-OSP-22.04. STARTING WITH #4 GOVERNOR VALVE.
11:50 SICK SEA TURTLE FOUND AT INTAKE CANAL INTRUSION NET.
IZ00 RICK HEREN OF LAND UTILIZATION NOTIFIED STATE OF FLORIDA SEA TURTLE STRANDING COORDINATOR @ 1130 OF SICK SEA TURTLE FOUND AT INTAKE CANAL INTRUSION NET. MANAGEME NOTIFICATIONS MADE.
12:35 DECLARED TURBINE GOVERNOR VALVE #4 BIS. EXITED FSAR SPEC 13.7.1.1 ACTION A FOR TURBINE OVERSPEED PROTECTION.
12:41 NOTIFIED NRC AND NDDO AND RESIDENT NRC INSPECTOR OF SICK SEA TURTLE FOUND AT INTAKE CANAL INTRUSION NET.
13:55 TURBINE VALVE TEST IAW 2-OSP-22.04 COMPLETED, SAT.
13:56 DECLARED RM-26-26 CONTAINMENT AIR MONITOR BIS FOLLOWING IC REPAIR, DECLARED RM-2625 OOS FOR MONTHLY ISC FUNCTIONAL IAW 2-IMP-26.05.
13:00 RM-26-62 CROAI MONITOR OOS DUE TO FAILED CHECK SOURCE, RM-26-66 OPERABLE, B TRAIN OUTS AIR INTAKE MONTHLY FUNCTIONAL COMPLETE.
14:10 18C PERFORMING SPENT FUEL POOL MONITOR MONTHLY FUNCTIOAL TEST lAW 2-IMP-26.35, ONE MONITOR AT A TIME.
3 NUMEER:
DATE:
SHIFT:
BOARD RCO:
DESK RCO:
NWE:
ANPS:
NPS:
US NRC ST LUCIE RESIDENT Mar 19 03 1:
47p 1
;
I Y