L-20-333, November 2020 Discharge Monitoring Report (NPDES) Permit No. PA0025615

From kanterella
(Redirected from L-20-333)
Jump to navigation Jump to search
November 2020 Discharge Monitoring Report (NPDES) Permit No. PA0025615
ML20366A089
Person / Time
Site: Beaver Valley
Issue date: 12/17/2020
From: Enos M
Energy Harbor Nuclear Corp
To:
Office of Nuclear Reactor Regulation, State of PA, Dept of Environmental Protection, Bureau of Water Quality Management
References
L-20-333, NPDES Permit No. PA0025615
Download: ML20366A089 (35)


Text

t-ener gy Beaver Valley Power Station Route 168 .

PO. Box4 harb or Shippingport, PA 15077-0004 Decempe r 17, 2020 L-20-333 Department of Environmental Protection Bureau of Water Quality Manageme_nt

  • Attention_:.DMR Clerk 400 Waterfron t Drive
  • Pittsburgh, PA 15222

SUBJECT:

Beaver Valley Power Station Discharge Monitoring Report {NPDES) Permit No.

. PA00256.15 .

Enclosed is the November 2020 NPDES Discharge Monitoring Report (DMR) for Energy Harbor Nuclear Corp, Beaver Valley Power Station (BVPS) in accordance with

~e requirement set forth in the site NPDES permit. Attachment 1 to this letter is supple111ental monitoring data for Outfall 001 (diss.olyed OXYQ.en). Also enc)Qsed is the 4 th quarter 2020 stonnwater report

  • A review of the data indicates no permit parameters were exceeded during the month,

~owever the required sampling frequency at Outfall 001 was not met. BVPS NPDES Permit {PA0025615) requires _continuous, measured flow at Outfall Q01. Outfall 001 flowmeter equipment malfunction occurred ori September 8, 2020 resulting in no available flow data for the months of September through November. An internal notification was-generated for equipment repair; Repairs are in progress and are 1=1nticipated to be complete by January 8, 2021. * *

  • Included with this report are two Suppleme n~I Laboratory* Accreditation Forms for analyses performed to support permit requirements as required by*25 Pa. Code§ 252.

Should you have any questions.regarding the attached ane enclosed documents, please direct them to Amy Savage, at 724-682-7359:

  • Sincerely, Matth w J. nos General Plant Manager

Beaver Valley Power Station, Unit Nos. 1 and 2 L-20-333 Page2 Attachment(s):

1. Weekly Dissolved Oxygen Monitoring Results at Outfall 001 Enclosure(s)

A. Monthly Discharge Monitoring Report B. 4th Quarter 2020 Stormwater Report C. Supplemental Lab Accredi4ltion Forms cc: c:~~~

- - --- . ~

emt @ *'.~

  • _11_ _ :$. !;.jR!i;..,!'(N_fiE: No new US NRG commitments are contained in this Jetter.)*

1 U nvironmental Protection Agency Ms. Amanda Schmidt, PA DEP/Bureau of Water Quality Management

, ---~-

L-20-333 Discharge Monitoring Report Attachment for NPDES Permit No. PA0025615 Beaver Valley Power Station November 2020 ATTACHMENT 1 Weekly Dissolved Oxygen Monitoring Results at Outfall 001 The following supplemental dissolved oxygen monitoring data for Outfall 001 is provided as agreed.

SAMPLE DATE SAMPLE TIME VALUE UNITS 11/01/2020 09:16 AM 8.00 mg/L 11/08/2020 _08:23AM 6.00 mg/L 11/15/2020 08:06AM 6.00 mg/L 11/22/2020 07:35AM 6.00 moll 11/29/2020 09:0SAM 8.00 mg/L

- Attachment 1 END -

3800-FM-BC'\W46212/2016 pennsylvania COMMONWEALTH OF PENNSYLVAMA DEPARTMENT OF ENVIRONMENTAL PROTECTION BUREAU OF CLEAN WATER r,6Jfj

  • '1111!!1 DEPARTMENT OF ENVIRONMENTAL PROTECTION DISCHARGE MONITORING REPORT (OMR)

NAME: B'l:RGYHARSORNUCI.EARcaa>

Reporting Frequency: Monthly ADDRESS: 76 S MAIN ST, Al<RON, OH , 44308 _ _PE_ RM

_PA0025S

_rr_ l'UIBE 15

_ _ _R I

_ ... 1l -- 0IJTF

- -AI.L

- 001_N__WBER

_ --1 DMR EffeeUve From: 11/01/2020 FACUTY: FIRSTI:t.B\GYBEAVERVALLEYPOWERSTATION 1 DMR EffeeUvt To: 11/3CW2020 LOCATION: PA ROUTE 168, SHPPINGPORT, PA, 15077 MONTORN) PERIOD Permit E,cpiret: 121%7/200&

STAGE: Final Blluent YEAR MO MY YEAR MO MY Permit Application Due: Ol'3CW200&

FROM 2020 11 01 TO 2020 11 30 No Discharge:

PARAMETER QUANTITY OR LOADING QUANTITY OR CONCENTRATION VALUE SAMPLNGFREQUENCY SAMPLNG TYPE VALUE UNIT'S VALUE SAMPLE MEAS\..ff:MENT

- - 8.1 VALUE VALUE 8.5 UNIT'S pH(00400)

PERMIT REQUREt.ENT

- - 6,0

- 9,0 s.u.

1/wBek Grab Arrmonia-Ntrogen (00610)

SAA'f'LE MEAS\..ff:11.ENT PERMIT REQUREM:NT

- -- ntMn

-- 00 Meritor & Report IMAX 00 Mcritor&Report mijL 1/wBek 1/wBek Grab Grab SAMPLE MEAS\..ff:11.ENT

- AIOMo GG l:l!II/Ma,(

GG Oamrol CT-1 (04251)

PERMIT REQUREM:NT

- .034

.034 mijL See Permit 24-1-t' C,omposite SAMPLE 11.EASl.ff:II.ENT E E AVJMo Dall\lM!II(

Flow (50050)

PERMIT REQUREMENT SAA'f'LE MEASI.H:11.ENT Morita &Report AIOMo Morita & Report OallyMIID<

MGO

-- - - Qnlru,ua Meaai.nd_

<..~

TOOi! Resic;.a Oilorine (TRC) (50060)

PERMT REQUREMENT

-- -~ .18 1,~ miiL 1/wBek Grab SAMPLE MEASl.ff:11.ENT

-- A1ogMo

<..08 IMAX

.18 1/wBek QrtilUQ Grab Recorded Free A\eilable Oiorine (50064)

PERMT REQUREMENT .2 .5 mi>'L Hycrnzine (81313)

SAA'f'LE MEAS\..ff:MENT PERMT REQUREM:NT AwMo GG

.rm OalvMIID<

GG

.wr miiL QrtilUQ 1/wtek Recorded Grab A\GMo OalvMID<

Facility Comments Prtvac:y Pollc:y I Sec:urtty Pollc:y COpyrtoht (1 2016 Corrmonweelth of Ponn1ylvanl1, All Rlghtl ~ H rvod

3800-FM-BC\W46212/2016 COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF ENVIRONMENT.AL PROTECTION pennsylvania BUREAU OF CLEAN WATER

  • , ~ DEPARTMENT OF ENVIRONMENTAL

'as PROTECTION DISCHARGE MONITORING REPORT (DMR)

NAME: eaGYHARBOR NUCI.EARC<R' Monthly Reporting Frequency:

ADDRESS: 78 S MAIN ST, AKRON, OH , 44308 .,___PERMIT_

P_M_~_

eme1_s_R_-11 1-0UTF--AU.-

... 002

_~-* - .-ER-....

DMR Effec11ve From: 11/01/2020 FACL ITY: ARS19ERGYBEAVER V/IUSPOWSt STATION 1 DMR Effec11ve To: 11/30f2020 LOCATION: PA ROUTE 188, SltPPINGPORT, PA, 15077 MON'l0RNG PERICO Permit E,cplres: 12/rT/7/JOI STAGE: Flnal Blluent VEAR MO D,t\V VEAR MO DAV Pennlt Application Due: Oll(30f7/JOI FROM 20ZI) 11 01 TO 20ZI) 11 30 No Olacharge:

QUANTITY OR LOADNG QUANTITY OR CONCENTRATION PARAMETER SAMPLNGFREQUENCY SAMPLNG TYPE VALUE VALUE UNITS VALUE VALUE VALUE UNITS SAMPLE MEASI.R:MENT .006 .046 1/week Flo.v (50050)

Estimate PERMT REQUIREM:NT Mcri!or & *Repc,1t Manila' & Repc,lt MGO A-.aMo Oaiiv MaK 1/Wl!ek Estimate Facility Comments Privacy Polley I Security Pollc:y Copyrtght ~ 2016 Corrm,nwealth of Penn1ylvanl1. All Right* ReH IVtd

3800-FM-BC \W462 12/2016 COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF ENVIRONMENTAL PROTECTION pennsylvan;a BUREAU OF CLEAN WATER DEPAATMENT OF ENVIRONMENTAL PROTECTION

.J **

DISCHARGE MONITORING REPORT (OMR)

NAME: EN:RGY HARBOR tU:l.EAR CORP ADDRESS: 78 S MAIN ST, AKRON, OH, 44308 ___PE _PAOOU815

_ RM rr_ ~- -E -R

--1 I I I-- OUTF - 003

- -AU. NUW6

-- ER- -t Reporting Freq1.1tncy:

DMR Effective From:

Monthly 11/01/2020 FACLITY: F1RSTBGGYBEAVERVAI.LEYPOWERSTAT10N 1 DMR Effectiw To: 11/30i2020 LOCATlON: PA R0UT1: 188, SHPPINGPORT, PA , 15077 MONlORN3 PERIOD Permit E,cpires: UJ:zT/2008 STAGE: Final Bftuent YEAR MO DAV VEAR MO DAV Permit Application Due: _Ofl_'J0/_2008 FROM 2020 11 01 lO 2020 11 30 No Discharge:

PARAMETER QUANTITY OR LOAD NG QUANTITY OR CONCENTRATION VALUE SAMPLNG FREQUENCY SAMPLNG TYPE VALUE UNITS VALUE VALUE VALUE UNrTS SAMPLE WEAS~IVENT .13 .11¥ Aow(50050) &'WNk Metered PERMT REQUIRl;M:NT Mcnil<< & Report Moolt.Qr&Report MOO AIOMo Dailv Ma,c 2/mordh Estimate Facillty Comments .

Privacy Polley I Security Polley Copyright "2016 Corrmonweelth of Pennsylvania. All Right* Reserved

3800-FM-BC\W462 12/2016 COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF ENVIRONMENTAL PROTECTION pennsylvania BUREAU OF CLEAN WATER

  • , ~ DEPARTMENT OF ENVIRONMENTAL

- PROTECTION DISCHARGE MONITORING REPORT (DMR)

NAME: ENH;YHARSOR NUCLEAR CORP Reporting Frequency: _

Monthl

__Y_ _ _ _ _ _ _ _ _ _ __

ADDRESS: 76 S MAIN ST, AKRON, OH , 44308 ..,.__P_ERMl'T

_P_AOOUe1

_ N.MJ

__ s_eR--11 1-0UTF--

>- A-U.004

_11U,1B

__ ER_--1 DMR Effective From: 11/01/2020 FACLITY: RRSTENERGY BEAVER V/UEf POWER STATION 1 0MR Effective To:

11/30i2020 LOCATION : PA ROUTE 168, SHPPINGPORT, PA, 15077 MONTORIIIG PERIOD Permit Expires: 12/%1/2008 STAGE: Flnal Bnuent VEAR MO DAY VEAR MO MY Permit Application Due: _oe1_*_ 200a FROM 2020 11 01 TO 2020 11 30 No Discharge: ~

PARAMETER QUANTITY OR LOADNG QUANTITY OR CONCENTRATION SAMPLNG FREQUENCY SAMPLNG TYPE VALUE VALUE UNIT'S VALUE VALUE SAMPLE MEASUREMENT

- VALUE UNrT'S pH (00400)

PERMT REOOREMENT SAMPLE t.EASUREMENT

- 6.0

.i r.tMn - 9,0 IMAX s.u.

1/'NNk Grab Flow (50050)

PERMT REQURe,l;NT MQ,jtor& ~ MQmor&RepQ!t MOO SAMPLE MEASUREMENT A10Mo l'llllllvMIII(

... 1/'Nllek Measl.nld Taal Residual Oiorine (lRC) (50060)

PERMIT Rl;QUREMl;:NT Ji 1,25 119L AIGMo IMAX 1/wilek Grab SAMPLE t.EASUREMENT Free A\llilable ~Oline (50064)

Facility Comments PERMT RECUREWENT

- - - ,2 AIG .Mo

,5 OlllyMII(

nvL 1/-..k Grab Pr1vacy Polley I Security Polley Copyright ©2016 Cornnonwe alth of Pennsylvan ia. All Rights Reserved

3800-FM-BC\W462 12/2016 COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF ENVIRONMENTAL PROTECTION pennsylvania BUREAU OF CLEAN WATER

, ,,,- DEPARTMENT OF ENVIRONMENTAL

  • - , PROTECTION DISCHARGE MONITORING REPORT (DMR)

NAME: ~HARBOR PfJCI.EARCORP Reporting Frequency: Monthly ADDRESS: 78 S MAIN ST, AKRON, OH, 44308 t---PERMIT

_ P_~ _ N..MBER

_ 1_5_--1, 1 0UTF

- -AU.

- ooe

_llUIS

__ER_ - t DMR Effective From: 11/01/2020 FACR..ITY: FIRSTB&G'i BEA~VALLEYPOWERSTATION 1 DMR Effective To: 11/3Clf2020 LOCATION: PA R0UT'E 188, SHPPINGPORI', PA, 15077 MON'TORtilG PERIOD Permit E,cplres: _121_11_1_200e STAGE: Flnal Blluent VEAR DAY MO VEAR MO MY Permit Application Due: O

_ fl

_3Clf

_ 200e FROM 2020 11 01 TO 2020 11 30 No Dlteharge:

QUANTITY OR LOADING PARAMETER QUANTITY OR CONCENTRATION SAMPLNG FREQUENCY SAMPLNG TIPE VALUE VALUE UNITS SAMPLE MEASLR:MENT .002 .01e ...

VALUE VALUE VALUE UNITS Flow (50050) 1/wNk Estimate PERMIT RECIURe,ENT Morltcr&Repc,rt Morltcr-&Repc,rt MGD A\fJMo Dliilv Ma,( 1Meek Estimate Facllity Comments

~

Prfvacy Polley I Security Polley Copyr1ght /L?2016 Corm-onwealth of Pennsylvania. All Rights ~served

3800-FM-BC\W462 12/2016 COMMONVVl:ALTH OF PENNSYLVANIA DEPARTMENT OF ENVIRONMENTAL PROTECTION pennsylvania BUREAU OF CLEAN WATER DEPARTMENT OF ENVIRONMENTAL

  • PROTECTION DISCHARGE MONITORING REPORT (DMR)

NAME: e.l:RGYHARBOR NUCLEAR CORP Reporting Frequency: Monthly

_ _PERMrT_PA00258_N.M:1E_1_s_R_-11 i-l-OVTF--Al.l-""'-IIA.M3--ER---i ADDRESS: 76 S MAIN ST, Al<RON, OH, 44308 DMR Effective From: 11/01/2020 FACLITY: FIRSTBERGY BEA~ VN.J.Ef POWSl STATION 1 DMR Effective To: 11/30(2020 LOCATION: PA ROlrrE 168, SHPPINGPORT', PA, 15077 MCNTORING PERIOD Permit E,cplrea; 1'l/'ZT/'JDOe STAGE: Final Blluent YEAR I MO I DAY I I YEAR MO DAY Permit Application Due: Oll(3Clf'JDOe FROM 2020 I 11 I 01 I TO I 2020 11 30 No Oiaeharge: 0 QUANTITY OR LOADING QUANTITY OR CONCENTRATION PARAMETER SAMPLING FREQUENCY SAMPLING TYPE VALUE VALUE UNITS VALUE SAMPLE MEASUREMENT - - ...

VALUE VALUE UNITS pH (00400)

PERMT REQI.JREMl;NT

- - M

-... 9,0 s.u. 1/week Grab Acm(50050)

SAMPLE MEASUREMENT ...

JnttMn IMAX Mcntor,&Rlpolt Mclrflor&Rlpol1 MGD PERMIT REQUREt/ENT SAMPLE MEASUREM:NT ...

AIGMo lllllv"-'< 1/wNk Estimate Total ResldJal Oiorine (TRC) (50060) .5 1.25 mi;>'L PERMIT REQUREWENT 1/week Grab Ava Mo IMAX Free Alailable Q-jorine (50064)

SAMPLE MEASUREWENT PERMT REQUIREWENT ... --- .z AwMo 5

Dl!lilv Ma,c

'"l)'L 1/v.eek Grab Facility Comments Pnvacy Polley I Security Polley Copyr1ght ~2016 COrm-onweaJth of P1nn1ylv1nla. All Right* ReHNtd

3800-FM-BC\W462 12/2016 COMMONWEA LTH OF PENNSYLVANIA DEPARTMENT OF ENVIRONMENTAL PROTECTION pennsylvania BUREAU OF CLEAN WATER DEPARTMENT OF ENVIRONMENTAL

  • PROTECTION DISCHARGE MONITORING REPORT (DMR)

NAME: EH:RGY HARBOR NUCLEAR CORP Reporting Frequency: Monthly ADDRESS: 76 S MAIN ST, AKRON, OH, 44308 .,___PE_RMIT_PA00256

_ "'-JMBE_1_s_R_ --1I 1-I-0lll"F

- -ALL-ooe_N>IS

__ ER_* --I DMR Effective From: 11/01/2020 FACLITY: FIRSTBERGY BEAVER V/IUEf POVVER STATION 1 DMR Effective To: 11/30(2020 LOCATION: PA ROUT1: 188, SHPPINGPORr, PA, 15077 MCNTORfG PERIOD Permit Expires: 12/27/2008 STAGE: Final Blluent YEAR MO DAY YEAR MO DAY Permit Application Due: 11&'30(2008 FROM 2020 11 01 10 2020 11 30 No Discharge: 0 QUANTITY OR LOAD NG QUANTITY OR CONCENTRATION PARAMETER SAMPLNG FREQUENCY SAMPLNG TYPE VALUE VALUE UNITS VALUE VALUE VALUE UNITS SAMPLE MEASUREMENT pH(00400)

PERMIT REQURJ;MENT 8.0 9,0 s.u. 2/mc:rth Grab SAMPLE MEASl.f!EWENT ir.tMn IMAX Total Suspended Solids (00530)

PERMIT REQUREMENT

- ... 30.0 100.0 mi>'L SAMPLE MEAS\.R:MENT

- ... /lillJMo IWvMI,( 2/mc:rth Grab Oil and Qease (00556)

PERMIT REQUREMENT SAMPLE MEASLR:MENT

- - -... ... 15 AlllMo 20 llllilvMI,(

mi>'L 2/mc:rth Grab Flow (50050)

Facility Comments PERMIT REQUREMENT Monitor: & Report A11JMo Mcnlt<< & Report DRilvMa,c MGD

- - - 1Mtlek Estimate Privacy Polley I Security Polley Copyrtght C 2016 Cormionwealth of Pennsyfv1nl1 . All Right* Re1erved

3800-FM-BC\W462 12/2016 COMMONWEA LTH OF PENNSYLVANIA DEPARTMENT OF ENVIRONMENTAL PROTECTION pennsylvania BUREAU OF CLEAN WATER

  • -J~ PROTECTION DEPARTMENT OF ENVIRONMENTAL DISCHARGE MONITORING REPORT (DMR)

NAME: EN:RGYHARBOR l'fJCI.EARCORP ADDRESS: 76 S MAIN ST, Al<RON, OH , 44308

_ _PERMIT

_ PA002Se

_ NMBE

_ 1_5_R_-11 i l -- ouw

- -AU.- 01

_1'1v.18

_0 _ _ -ER- - Reporting Frequency:

DMR Effective From:

Monthly 11/01/2020 FACLITY: RRSTEH:RGY BEAVER VN.J.Ef POWER STATION 1 DMR Effective To: 11/3Clf2020 LOCATION: PA R0UT'E 188, SHPPINGPORT, PA, 15077 MOlll10RfllG PERIOD Permit E,cplres: 12/1:T/2/J08 STAGE: Anal Bnuent VEAR MO OAV VEAR MO OAV Permit Application Due: Oll(3Clf200S FROM 2020 11 01 10 2020 11 30 No ot, charge:

PARAMETER QUANTITY OR LOADING QUANTITY OR CONCENTRATION SAMPLNG FREQUENCY SAMPLNG TYPE uNrrs VALUE SAMPLE MEASUREMENT VALUE UNITS VALUE 1,e VALUE

... VALUE 1,9 11\wek Grab pt-1 (00400)

PERMIT REQUIREMENT 0,0 9,0 s.u. 1/week Grab lr>>tMn .

IMAX SAMPLE MEA8UREWENT GG GG Oamtrol Cf-1 (04251)

PERMT REQUIREMENT

- .034 .034 mi>'L Delly~ DlsdWIJng 24-H' eon,xisite F)c,y (50050)

SAMPLE MEASUREMENT PERMT REQUIREJJE.NT 3.46 Monitor & Report 4.32 Monitor&Report MGO A1g,Mo DailvMalc 1/week 1/week Measured SAMPLE MEA8UREM:NT A1gMo DailvMa,c

- Measured

,()6 ,()6 1/Week Grab TOOi! Resiwal Q-,laine (TRC) (50060)

PERMTREOOREM:NT

-- - .5 1.25 "9'l 1/week Grab SAMPLE MEA81.R;MENT A1g Mo

<,02 IMAX

.4 1/week Grab Free A\eilable Q-,laine (50064)

Facility Comments PERMT REQUIREMENT

- ,2 A141Mo

.5 Cl!!llv Male

'"9'l 1/week Grab Privacy Polley I Security Polley Copyright ()2016 Con-monwealth of Pennsylvania. Alf Rights Reserved

COMMONWEALTH OF PENNSYLVANIA 3800-FM-BC\W462 1212016 DEPARTMENT OF ENVIRONMENTAL PROTECTION pennsylvania BUREAU OF CLEAN WATER DEPARTMENT DF ENVIRONMENTAL

  • PROTECTION DISCHARGE MONITORING REPORT (DMR)

NAME: 8'ERGYHARSOR NUCLEAR CORP Reporting Frequency: Monthly

_ _PERMIT

_ P_A00:258

_11U48E

_ 1_s _R

_-11 - o..m::

- -AU.

- 01

_1\lM8 1_ - -

ER-. --I ADDRESS: 76 S MAIN ST, AKRON, OH, 44308 1-l DMR Effeclive From: 11/01/2020 FACLITY: RRSTBl:RGY BEA~ VN..lE( POWER STATION 1 DMR Effective To: 11/30(2020 LOCATlON: PA ROUTE 168, SHPPINGPORT, PA , 15077 MONTORNG F'ERIOO Permit Expires: 12/%7/2008 STAGE: Anal Blluent YEAR MO MY VEAR MO MY Permit Application Due: _Olll_30f_2008 FROM 2020 11 01 10 2020 11 30 No Discharge:

QUANTITY OR LOAONG QUANTITY OR CONCENTRATION PARAMETER SAMPLNG FREQUENCY SAMPLNG TIPE VALUE VALUE UNITS VALUE VALUE VALUE UNITS Flow (50050)

SAMPLE MEASUREMENT PERMIT REQURBIENT

.004

  • ~&Repoit

.004 Morflor&Repoit MGD 1/Week 1/Week Estimate Estimate A1gMo OllilvMax Facility Comments Prtvacy Polley I S curtty Polley COpyri9ht ~2016 Corrmonwealth of Pennsylvania. All Right* Re11rv1d

3800-FM-BC\W46212/2016 COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF ENVIRONMENTAL PROTECTION pennsylvania BUREAU OF CLEAN WATER

  • OEPAlmlENT OF ENVIRONMENTAL PROTECTION DISCHARGE MONITORING REPORT (DMR)

NAME: BERGY HARBOR NUCLEAR CORP Reporting Frequency: Monthly ADDRESS: 76 S MAIN ST, AKRON, OH, 44308 ...,__P_E-: -~-~ - 1_5_R_ -11 i l - - OUTF

- -ALl

- 01

_"'-W z _ .- ER- - t DMR Effective From:

FACILITY: FIRSTEtaGYB EA~ VALLEYPC7NERSTA110N 1 DMR Effective To:

11/01/2020 11/3Clf2020 LOCATION: PA ROUTE 168, SHPPINGPORT, PA, 15077 MONTORING PERIOD Permit E,cplree: 12/%7/2008 STAGE: Final Blluent YEAR MO DAV VEAR MO DAV Permit Application Due: _ot1_3Clf

_ 200e FROM 2020 11 01 TO 2020 11 30 No Dlacharge:

PARAMETER QUANTITY OR LOADING QUANTITY OR CONCENTRATION SAMPLNGFREQUENCY SAMPLNG TYPE VALUE VALUE UNIT'S VALUE VALUE VALUE SAMPLE MEASUREMENT

- -- 8.0 8.2 UNITS pH(00400) 2/month Grab PERMIT REQIJREMENT 6.0 9.0 s.u.

1/morih ntMn IMAX Grab SAMPLE l'.EASL.ff:MENT <.025 <.025 2/month C,opper, Total (01042)

PERMIT REQIJREMENT

- Mcrilor&Report Molilor&Report nv'L 2/month Grab AIOMo DlllvMIIDI Grab SAMPLE ~l.ff:MENT <.02 .02 2/month 21nc:, Total (01092) Grab PERMT REQIJREMENT 15 1.5 nv'L 2/month SAMPLE ~UREMENT .001 .001 -

AIGMo DIIIYMIIDI 1/month Grab Estimate Flow (50050)

PERMIT REQUREMENT Morfla :& Report Mritor&Report MGD

  • - - 1/month AIGMo Daily .MaK Estimate SAMPLE ~UREMENT 320 380 Total Oissd-.ed Scjids (70295)

PERMT REQIJREMENT - ... Mor;torA 'Report AIGMo Monitor & Report Calv MIIDI "l>'L 2/month 2/month Grab Grab Facility Comments Pr1vecy Pelley I S curtty Polley Cc,pyr1ght (C)2016 Co~nw 11th of Ponn,vl111nl1. All ~htl Roll"'Od

3800-l<M-BC\W462 12/Z016 COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF ENVIRONMENTAL PROTECTION pennsylvania BUREAU OF CLEAN WATER

  • , ~ DEPARTMENT OF ENVIRONMENTAL

'1111!1 PROTECTION DISCHARGE MONITORING REPORT (DMR)

NAME: ENERGY HARBOR NUCLEAR CORP Reporting Frequency: Monthly 1 01 ADDRESS: 78 S MAIN ST, AKRON, OH, 44308 _s_R

_ _P_ERM_PA00258_rr_~_ _ - 11 I--OUTF - -ALL

- - ~- .- ER DMR Effective From: 11/01/2020 FACUTY: RRSTB&G'f BEAVER V/UEf POWER STATION 1 DMF'{ Effective To: 11/3Gf2020 LOCATION: PA ROUTE 168, SHPPINGPORT, PA, 15077 MON'l'ORIIG PE~ Permit E,cplrea: 12/27/200&

STAGE: Flnel Effluent YEAR MO DAY YEAR MO DAY Permit Application Due: _ot1_30f

_ 200&

FROM 2020 11 01 TO 2020 11 30 No Discharge:

QUANTITY OR LOADING QUANTITY OR CONCENTRATION PARAMETER SAMPLNGFREQUENCY SAMPLNG TYPE SAMPLE MEASUREMENT VALUE VALUE UNITS VALUE VALUE VALUE UNITS 7.1 7.8 1/wetl< Grab pH(00400)

PERP.ff REQUREMENT - - 6.0 9.0 s.u. 1/wetl< Grab SAMPLE MEASUREIVENT - - -

Inst Mn

<.01 IMAX

<.01 2/month 24-1-t composite Cyande. Total (00720)

PERP.fT REQUREMENT SAMPLE MEASUREMENT -- -- -- Mcritor&Report A\aMo

<,001 Mmtclr'&Rlpcrt Clllv,Max

<,001 mgL 2/month 24./+Canposite 2/month 24-1-t comooslte o-4orobenzene (34301)

PERP.ff REQUREMENT SAMPLE MEASURelENT

-- M:nlQr&Report A141Mo Mcrilor&Report Clllv .Ma,(

"l>'L 2/month 24-1-t Canposlte Copper, Total (01042)

PERP.fT REQUREMENT ... - -

<,025 Mcriklf&Report c:025 Mcrilor&Rer;lclrl mgL 2/month 2/month 24./-t CM-aiaite 24./-t Canposite Aow (50050)

SAMPLE MEASUREMENT PERMT REQUREMENT

.002 Moritor & *Report A\OMo

.002 Moritor&Report Delly Max MGO A141Mo DllllvMIK

... 2/month 2/month Estimate Estimate Faclllty Comments Pnvaey Polley I Security Polley Copyright ~ 2016 Cornnonwealth of Pennsylvania . All Rights Reserved

3800-FM-BC\W462 12/2016 COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF ENVIRONMENTAL PROTECTION pennsylvania BUREAU OF CLEAN WATER

  • r~

'111118 DEPARTMENT OF ENVIRONMENTAL PROTECTION DISCHARGE MONITORING REPORT (DMR)

NAME: eaGYHARBOR NUCLEAR CORP Monthly Reporting Frequency:

ADDRESS: 76 S MAIN ST, AKRON, OH, 44308 __PERM

_ P_~- ~ -* _1_s_ER- -11 f-l- OUTF --AU.-1-~- -ER- -t 0MR Effective From: 11/0112020 FACLITY: RRSTI!NERGY BEAVER V1'L1.Ff POWBt STATION 1 DMR Effective To: 11/3Gf2020 LOCATJON: PA ROUTl: 168, SttPPINGPORT, PA , 150TT MOlll'TORING PERIOD Permit E,cplres: 1'Z/%7/2DOt STAGE: Flnal Effluent YEAR MO I o,\Y I YEAR I MO DAY Permit Application Due: _oeJ_3Gf

_ 2DOt FROM 2020 11 I 01 I TO 2020 I 11 30 No Discharge:

PARAMETER QUANTTl'Y OR LOADING QUANTTl'Y OR CONCENTRATION SAMPLING FREQUENCY SAMPLING TYPE VALUE VALUE UNITS VALUE VALUE VALUE UNITS SAMPLE MEASUREMENT pH (00400)

PERMTREQURB,ENT 8,0

- 9.0 s.u. 1Melll(

Grab lnttM.n ~

SAAf'I.E IVeASUREMENT Total Suspended Solids (00530)

PERMT REOUREMENT 30.0 100.0 nv'L SAMPLE MEASUREMENT -- - - AloMo l'Wh,MII,( 1/week ~ite OH and Grease (00556)

PERMT REQUREMENT

-- - 15 20 nv'L 1/week SAMPLE MEASUREMENT

- AIGMo Olllv Max Grab Arrmoria-Ntrogen (00610)

PERMT RECIUREMENT SAMPLE IVeASUREMENT

- - Meritor & .Rec,crt Ava Mo

~&Report Ollllv Max mi>'L 1/week Grab Aow (50050)

PERMT REQUREMENT SAMPLE MEASUREMENT Monita-&RepQ!t AIG Mo

~&Aeport Dlili, Ma,c MGD

-- - - Contif1UOU8 Measl.n.!d 1-t)'ci'azine (81313)

Facility Comments PERMT REQURelENT

- - - Monltor&Aeport AIGMo Monffor.&Rlpolt n.lv 'Ma,c nv'L 1/week Grab Privacy Polley I Security Policy Copyright ©2016 Corrrnonwealth of Pennsylvania. Alf Rights Reserved

3800-FM-BC\W462 12/2016 COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF ENVIRONMENTAL PROTECTION pennsylvania BUREAU OF CLEAN WATER rlill!rl DEPARTMENT OF ENVIRONMENTAL

  • 'llifl9 PROTECTION DISCHARGE MONITORING REPORT (DMR)

NAME: eaGY HARBOR NUCLEAR CORP Reporting Frequency: _Monthl

_ _Y_ _ _ _ _ _ _ _ _ __ _

ADDRESS: 76 S MAIN ST, AKRON, OH, 44308 _ _PERM

_ P_~_lll.MBE_1

_s_R

_ -1I i-l- ovrr:

--AU. -1

-:w

- -ER- -1 DMR Effective From: _

11_101_1_2020 FACUTY: FIRSTB&Gf BEA~ VAU.Ef POWER STATION 1 DMR Effective To: 11/30(2020 LOCATION: PA ROUTE 188, sttPPINGPORI', PA, 15077 MONTORNG PERIOD Permit Expires: _12m_I_200&

STAGE: Final Blluent YEAR MO MV YEAR MO MY Permit Application Due: _Ofl_30f_2006 FROM 2020 11 01 10 2020 11 30 No Discharge:

QUANTITY OR LOADNG QUANTTTYORCONCENTRATJON PARAMETER SAMPLNGFREQUENCY SAMPLNG TYPE SAMPLE MEASUREMENT VALUE

-- VALUE

-- UNrT'S VALUE T.8 ...

VALUE VALUE 7.11 UNrT'S 2/monlh Grab pH(00400)

PERMT REQUREMENT SM-Pl.E MEASLR:MENT - -

6.0 Inst Min *- 9.0 IMAX 7.1 s.u. 2'11101ih 2/lllOlih Grab

~ -8 Grab Tcxal Suspended Solids (00530) :l>,O 100.0 PERMTREQURB.ENT nvL 2/lllOlih Grab AIG Mo llallvMIIII SM-Pl.E ~MENT

<5 ~ 2/lllOlih Grab Oil and Grease (00556)

PERMT REQUREMENT 15 20 nvL 2/lllOlih Grab Alll ,M()

SAMPLE MEASI.R:MENT .001 .001 -

DallvMa,c 2'11101ih Estimate Flem (50050)

Facility Comments PERMT REOUREWENT Morflor&Repat A10Mo Mtntor&~

OilllvMII(

MOO

- 2/lllOlih Estimate Privacy Polley I Secur1ty Polley Copyrtght ©2016 COrnnonwealth of Pennsylvania. All Rights Reserved

3800-FM-BC\W46212/2016 COMMONWeALTH OF PENNSYLVANIA DEPARTMENT OF ENVIRONMENTAL PROTECTION pennsylvania BUREAU OF CLEAN WATER

  • '1111!!1

,~ DEPARTMENT OF ENVIRONMENTAL PROTECTION DISCHARGE MONITORING REPORT (DMR)

NAME: eaGY HARBOR NUCLEAR CORP Reporting Frequency: Monthly ADDRESS : 76 S MAIN ST, AKRON, OH, 44308 __PERMIT_PA002H_l'Uv1BE_1_s_R_-111i--OUTF--ALL-1-:w--ER--

DMR Effective From: 11/01/2020 FACUTY: FIRSTBBG Y BEAVER VN.J.Ef POWERSTATION 1 DMR Effective To: 11/30f2020 LOCATION: PA ROUTE 168, SHPPINGPORr, PA, 15077 MONTORN .; PERIOD Permit Expires: 12/%7/:ZOOS STAGE: Final Blluent VEAR MO DAV VEAR MO DAV Permit Application Due: _ot1_30f

_ :zoos FROM 2020 11 01 TO 2020 11 30 No Discharge:

PARAMETER QUANTITY OR LOADNG QUANTITY OR CONCENTRATION SAMPLNGFREQUENCY SAMPLNG TYPE SAMPLE MEASUREMENT VALUE VALUE

- UNITS VALUE VALUE VALUE UNrT"S pf-1(00400) 1,5 1,1 2/month Grab PERMIT REOUREMENT 6,0 9,0 s.u.

SAMPLE MEASUREMENT ...

lrwt'Min IMAX 2/month Grab

... <4.0 <4.0 Total Suspended Solids (00530) 2/month 24-t-t~ ite PERMT REQURE.M!:NT 30.0 100.0 lnl>'L 2/month 24-H-Composite SAMPLE MEASUREMENT .13 .196 AIGMo Dl!ilvMe,(

Flc.v(50050)

Facillty Comments PERMIT REOOREMENT Monlta&Repc,rt AIGMo MonltCJr&Repolt DlllvMa,c MGO

- - - 2/month 2/month Estimate Estimate Privacy Polley I Security Polley Copyr1ght @2016 Cornnonwealth of Pennsylvania, All Rights ReHNed

3800-FM-BC\W462 12/2016 COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF ENVIRONMENTAL PROTECTION pennsylvania BUREAU OF CLEAN WATER DEPARTMENT OF ENVIRONMENTAL

  • PROTECTION DISCHARGE MONITORING REPORT (DMR)

NAME: B£RGY HARBOR NUCLEAR CORP Reporting Frequency: Monthly 1---PERMT_PA002

_ _1\l.MBE

_511_1_s_R_ -11 1-1-0UTF

- -AU.-1_1"°"8

_1 - -ER - --i ADDRESS : 76 S MAIN ST, Al<R0N, OH, 44308 DMR Effective From: 11/01/2020 FACLITY: FIRSTlJl:RG'f BEA~ VAUEY POWER STATION 1 DMR Effective To: 11/3(1(2020 LOCATION: PA R0UT'E 168, SHPPINGPORT, PA, 15077 MONTORf,G PERIOD Permit E,cpirea: 12/:Z,/200&

STAGE: Rnal B'lluent VEAR MO DAV VEAR MO MV Permit Application Due: Oll,'3Ct(21JO&

FROM 2020 11 01 10 2020 11 30 No Discharge:

QUANTITY OR LOAONG QUANTITY OR CONCENTRATION PARAMETER SAMPLNG FREQUENCY SAMPLNG TYPE VALUE SAMPLE MEASUREMENT VALUE

... UNITS VALUE 7,7 VALUE VALUE u

UNITS 1/wNk pH (00400)

PERMT REQURa,ENT SAMPLE MEASLR:MENT ... -

-... e.o kwtMin 9.0 IMAX s.u. 1/week Grab Grab

<U 13.5 1/wNk Grab Total Suspended Solids (00530)

PERMT REQUREM:NT 30.0 100.0 "9'L 1/wNk Grab Al.rt Mo DallvMa,c

~

SAMPLE MEASUREMENT <5.1 <5.2 1/wNk Grab Oil and Grease (00556)

PERMT RECUREM:NT SAMPLE MEASLR:MENT .002

.002 15 AIOMo

~

Dllllv *Ma,c "9'L 1/wNk Grab 1/WIClk Estimate Aow(50050) Monitor,&.Report Monitor &Report MOO PERMIT REQUREM:NT 1/wNk Estimate AIOMo l:RlvMID(

Facility Comments P11vacy Polley I Security Polley Copyt19ht IC>2016 Comrronwealth of Pennsylvania. All Rights Reserved

3800-FM-BC\W46212/2016 COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF ENVIRONMENTAL PROTECTION pennsylvania BUREAU OF CLEAN WATER DEPARTMENT OF ENVJRONMENTAL

  • PROTECTION DISCHARGE MONITORING REPORT (DMR)

NAME: BIERGYHARBOR NUCLEAR CORP Reporting Frequency. _

M_onthl _Y_

PA0025815 113 _ _ __ _ _ _ _ _ __

ADDRESS: 76 S MAIN ST, AKRON, OH , 44308 DMR Effective From: _

11_101_1_2020 PERMrT~ER OUTFALi. ~ER FACUTY: FIRSTBBGY BEAVER VN.l.F( PONER STATION 1 DMR Effective To: 11/30(2020 LOCATION: PA ROUTE 188, SHPPINGPORr, PA, 15077 MONTORING PERIOD Permit E,cpires: 12'%7/2IIOI STAGE: Final Blluent VEAR MO DAY YEAR MO MV Permit Application Due: _oe1_'JOl_21101 FROM 2020 11 01 10 2020 11 30 No Discharge:

QUANTl1Y OR LOADING QUANTTTV OR CONCENTRATION PARAMETER SAMPLNGFREQUENCY SAMPLNG TYPE uNrrs uNrrs VALUE VALUE VALUE VALUE VALUE SAMPLE MEASUREMENT -

pH(00400)

PERMIT REQURWENT 6,0 9,0 s.u. 2/morth Grab ntMn IMAX SAMPLE MEASUREt.ENT Total Suspended Solids (00530)

PERMIT REQUIREMENT" 30,0 80,0 "9'L. 2/morth &-1-t Coinpoalte A\C!Mo _OllilvMax SAMPLE MEASUREt.ENT Flow (50050) .043 Moritcr&Rep:,rt MGO PERMIT REQUIREt.ENT SAMPLE MEAS~NT --

A\OMo DllllvMax 1/waek Measl.nld Total Residual 0-.orine (1RC) (50060)

PERMTREQUIREM:Nr 1.4 3.3 "9'L Fecal Coliform (74055)

SAMPLE MEASUREMENT' PERMIT REQUREP.ENr

-- -- A'41Mo 2000 IMAX No.11oom 2/morth Grab

-- -- -- GeoMeai 2/morth Grab Gabonaceous Biochemical Oxygen Demn:t SAMPLE MEAS~NT (c:BOO;) (80002) PERM'T REQUREMENT 2.5.0 50.0 "9'L 2/morth A'41 Mo Oellv Max &-1-t~ite Facility Comments Prfvacy Polley I Securtty PolJcy Copyr1ght ()2016 Conmonwealth of P1nn1ylv1nl1. All Rights ReseNed

3800-FM-BC\W462 12/2016 COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF ENVIRONMENTAL PROTECTION pennsylvania BUREAU OF CLEAN WATER DEPARTMENT OF ENVIRONMENTAL

  • PROTECTION DISCHARGE MONTORING REPORT (DMR)

NAME: eaGYHARBORNUCLEAR CCH>

Reporting Frequency: Monthly ADDRESS: 76 S MAIN ST, AKRON, OH , 44308 - -PE-: -~-t,U1BE-1

_5_R_-11 I-I- OIJTF

- -ALL

- 203

_fll.Mil

__ER _--t OMR Effective From: 11/01/2020 FACR..ITY: RRSTB&GY BEAVER V/UEf PONER STATION 1 DMR Effective To: 11/30f2020 LOCATION: PA ROUTE 168, SHPPINGPORT, PA, 15077 MON'IORNG PERICO Permit Expires: 12/%7/2008 STAGE: Anal Blluent YEAR MO DAY YEAR MO DAY Permit Application Due: CMl{30f2D08 FROM 2020 11 01 10 2020 11 30 No Discharge: el QUANTITY OR LOAONG QUANTITY OR CONCENTRATJON PARAMETER SAMPLING FREQUENCY SAMPLING TYPE VALUE VALUE UNn"S VALUE SAMPLE MEASUREII.ENT VALUE VALUE UNn"S pf-1(00400)

PERMITREQIJREMENT

- 8,0 9.0 8.U.

Total Suspended Solids (00530)

SAMPLE MEAS~NT PERMIT REQUIREMENT -- -

ntMn 30.0 IMAX 80.0 flll>'L 2/mcrth 2/month Grab Mt Composite A1gMo llllilvMax SMf'>lE MEASI.R:M=NT AC7N (50050) .OZ3 Marit<<&Repcrt MGD PERMT REOUREM=NT Total Resicllal 0"4orine (lRC) (50000)

SAMPLE MEASI.R:M=NT PERMTREOUREM=NT Av;; Mo lllillltMax

-- 1.4 3.3 llll>'L 1/'Mll!k Measl.l'8d

-- 2/mcrth Grab SMf'>lE MEAS~NT .... A-.aMo IMAX Fecal Coliform (74055)

PERMIT REQUREM=NT

- - - 200() No.11oom SAMPLE MEASI.R:M=NT - - GeoMeal 2/mcrth Grab Carbonaceous Biochemical Oxygen Demand (CB005) (80082)

Facility Comments PERMIT REQUREMENT

- - - 25.0 A1g Mo 50.0 Dl!iilvMa,c flll>'L 2/month Mt"Composlte Privacy Polley I Security Polley Copyright ~2016 Colffl"Onwealth of Penn1ylvanl11. All Rights Reserved

3800-FM-BC\W462 12/2016 COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF ENVIRONMENTAL PROTECTION pennsylvania BUREAU OF CLEAN WATER

,~ DEPARTMENT OF ENVIRONMENTAL PROTECTION DISCHARGE MONITORING REPORT (DMR)

NAME: ENRGY HARBOR NUCl.EAR C(H)

Reporting Frequency: Monthly ADDRESS: 76 S MAIN ST, AKRON, OH, 44308 t---P-ERMIT_P_A00258_N..M3E_1_5_R_-11 1-I-OUTF--ALL-21 --ER---1

_Nl.t.18_1 DMR Effective From: 11/01/2020 FACLITY: ARSTENER GYBEAVER VAU.EY~ST A110N 1 DMR Effective To: 11/3CW2020 LOCATION: PA ROUTE 168, SHPPINGPORT', PA, 15077 MONTORN:; l'ERIOO Permit E>cpire9: 12/%7/2tl06 STAGE: Final Bftuent YEAR MY MO YEAR MO DAY Permit Applic:21tfon Due: 06'.2tl06 FROM 2020 11 01 'TO 2020 11 30 No Dt1c:harge:

PARAMETER QUANTITY OR LOADNG QUANTITY OR CONCENTRATION SAMPLNG FREQUENCY SAMPLNG TYPE VALUE VALUE UNITS VALUE VALUE VALUE UNITS SAMPLE MEASUREMENT 7,5 pH (00400) 8,1 1/week Grab PERMT RECIUREMENT (5.0 9.0 s.u.

1/week Inst Mn IMAX Grab SAMPl.E MEASUREMENT <8.3 11.7 Total Suspended Solids (00530) 1/week Grab PERMT REQUREMENT 30.0 100,0 mi>'L 1/week A!aMo DallvMaK Grab SAMPl.E MEASUREMENT Oil and Q-ease (00556) l'ERMT RECIUREtJENT

<5.1 15

<5.1 20 mi>'L 1/week Grab A\G-Mo DlllvMIK 1/week Grab SAMPLE MEASUREMENT .002 .002 Flc,,v(50050) 1/week Estimate PERMT REQUREMENT Mentor & Report Morita' & Report MGO AIGMo DIIIYMaK 1/week Estimate Facility Comments Pnvacy Polley I Security Polley Copyright ©2016 Corrmonwealth of Pennsylvania . All Rights Reserved

COMMONWEALTH OF PENNSYLVANIA 3800-FM-BC\W462 12/2016 DEPARTMENT OF ENVIRONMENTAL PROTECTION pennsylvania BUREAU OF CLEAN WATER

  • rJJillll!J DEPARTMENT Of ENVIRONMENTAL

- , PROTECTION DISCHARGE MONITORING REPORT (DMR)

NAME: EN:RGY HARBOR NUCLEAR CORP Reporting Frequency: Monthly ADDRESS: 76 S MAIN ST, AKRON, OH , 44308 i----P-ERMIT

_PA0025tl

_*_* ~- 1-5 -ER- -11 1-1- 0IJTF

- -AU. -. 21

_ IIU-18

_3 __  !;R

_ -I OMR Effective From: 11/01/2020 FACILITY: ARSTBERGY BEAVER VAUEf PO'NER STATION 1 DMR Effective To: 11/30f2020 LOCATION: PA ROUTE 168, SHPPINGPORT, PA, 15077 MONTORm PE~ Permit Expires: 12/%7/2D08 STAGE: Final Bnuent YEAR MO OAY YEAR MO OAY Permit Applleallon Due: Ol/3(1(2D08 2020 11 01 TO mo 11 30 No Dl1ehsrge: ~

QUANTITY OR LOADING QUANTITY OR CONCENTRATION PARAMETER SAMPLING FREQUENCY SAMPLING TYPE SAMPLE MEASUREMENT VALUE VALUE uNrrs VALUE VALUE VALUE UNrrS pi-1(00400) 6.0 9.0 s.u.

PERMTREOUREMENT 2/monlh Grab Inst Mn IMAX Total Suspended Solids (00530)

SAMPLE MEASUREMENT PERMIT REOORB.ENT ,... ... 30,0 100.0 11'11)'L 2/monlh Grab SAMPLE MEASUREMENT - ... ... AIO:Mo l'WlvMl,i on and Q-ease (00556) PERMT,REOOREMENT 15 AIOMo ' ~MID<

20 nv'L 2/monlh Grab SAMPLE MEASUREMENT F1cM' (50050) *Mintor& ,Repat * .* Mentor & Repat MGD PERMTREOORaENT 1/\INk Estimate Total Rasia.Jal Ollorine (TRC) (50060)

SAMPLE MEASUREMENT PERMIT REQUREMElirr AIGMo

  • Ol!llvMa,i

.5 1.25 nvL 2/monlh Grab AIOMo IMAX Facility Comments Pr1vac:y Polley I Sec:ur1ty Polley Copyright IC)2016 Corrmonwealth of Pennsylvania. All Rights Reserved

3800-FM-BC\W462 12/2016 COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF ENVIRONMENTAL PROTECTION pennsylvania BUREAU OF CLEAN WATER

  • ,'1111!1

~ DEPARTMENT OF ENVIRONMENTAL PROTECTION DISCHARGE MONITORING REPORT (DMR)

NAME: ENRGY HARBOR MJClEAR CORP Reporting Frequency: Monthly ADDRESS: 76 S MAIN ST, AKRON, OH, 44308 ......_P_ERM

_P_~_Nl.fleE

_ 1_s_R _-tl 1-i- 0VTF--AU.-~

-IIU,,'

-- 8ER- - OMR Effective From: 11/01/2020 FACft..fTY: FIRSTIH:RGY BEA~ V/!IJ.J.Ff POI/VER STATION 1 OMR Effective To: 11/30i2020 LOCATION: PA ROUT'E 168, SHPPINGPORT, PA, 15077 M0N'Tt'JRt,IG l'ERIOO Permit E,cplrea: 12/27/2008 STAGE: Final Blluent YEAR MO MY VEAR MO MY Permit Application Due: Oll30f200II FROM 2020 11 01 TO 2020 11 30 No Discharge: ~

PARAMETER QUANTITY OR LOADING QUANTITY OR CONCENTRATION SAMPLNG FREQUENCY SAMPLNG TYPE VALUE Total Suspended Solids (00530)

SAMPLE MEASUREIVENT PERMT REQUIREMENT VALUE UNITS VALUE VALUE 30.0 VALUE 100.0 UNITS nvL 2/monlh AIGMo Dallv Max Grab SAMPLE MEASUREM:NT Oil and Grease (00556)

PERMIT REOUREMENT

- 15 20 r,vL 2/monlh Grab AIGMo Dlilv Max SAMPLE MEASUREM:NT Flow (50050) t.bitor&Repat Mcntor&Repat MGD PERMIT REOUREMENT 11¥,wk A141 Mo Dallv Ma Estimate Facility Comments Privacy Polley I Security Polley Copyl19ht ()2016 Corrmonweelth of Pennsytv1nl1. Alf Rights Reserved

3800-JiM-BC\W46212/2016 COMMO NWEAL TH OF PENNSYLVANIA DEPARTMENT OF ENVIRONMENTAL PROTECTION pennsylvania BUREAU OF CLEAN WATER

  • DEPARTMENT DF ENVIRONMENTAL PROTECTION DISCHARGE MONITORING REPORT (OMR)

NAME: ENERGY HARBOR NUCLEAR CORP ADDRESS: 76 S MAIN ST, Al<RON, OH, 44308 __PE_RM_PA00251115 IT_N.NS

_ _E _R_-1I I 1-- 0l/TF -. 303

- -Al.l -N..W

- -eR ----t Reporting Frequency:

DMR Effective From:

Monthly 11/01/2020 FAClJTY: FIRS'T1H:RGYBEAVERVAU.EYPOWERSTA110N 1 DMR Effective To: 11/30(2020 LOCATION:PAROUTc168, SHPPINGPORT, PA, 15077 MONTORING PERIOD Permit Expires: 12/%7/2008 STAGE: Final Blluent VEAR MO DAY YEAR MO DAY Permit Application Due: 06'30(2008 FROM 2020 11 01 10 2020 11 30 No Discharge: 0 PARAMETER QUANTITY OR LOAD NG QUANTITY OR CONCENTRATION VALUE SAMPLNGFREQUENCY SAMPLNG TYPE VALUE UNITS VALUE VALUE VALUE UNITS SAMPLE MEASUREMENT pH(00400)

PERMIT REQUREMENT

- 6.0 9.0 s.u.

JrwtM.n IMAX 1/week Grab SAMPLE MEASUREMENT Total Suspended Solids (00530)

PERMT REOUREM:NT 30.0 100.0 n-o'L

- Al(! Mo DllilvMaK 1/-.-k Grab SAMPLE MEASUREMENT Oil and Grease (00556)

PERMIT REQUREMENT

- - -- 15 20 ""9'L 1/-.-k Ao.v(50050)

SAMPLE MEASUREMENT PERMT REOUREMENT Moritor&R epat AVJMo Montor&R epcrt c.tvMex MGD A11gMo Dally Max 1/-.-k Grab Estimate Facility Comments Privacy Polley I Seturfty PolJty Copyright ©2016 ConTnOnwea~h of Pennsylvania. All Rights Reserved

3800-FM-BC\W46212/2016 COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF ENVIRONMENTAL PROTECTION pennsylvania BUREAU OF CLEAN WATER

  • OEPARTMEl'll' OF ENVIRONMEl'lTAL PROTECTION DISCHARGE MONITORING REPORT (DMR)

NAME: EHRGYHARBOR NUCLEAR CORP Reporting Frequency: Monthly ADDRESS: 76 S MAIN ST, AKRON, OH, 44308 _ _P_ERM

_PA0025e

_rr_ l(.M8£

_ 1_5_R_-11 i-l- OIJTF

- -AU..- 3_1-~ -ER---t OMR Effective From: 11/01/2020 FACR..ITY: ARSTENERGY BEAVER V/W.Ef POWER STATION 1 OMR Effective To: 11/30f2020 LOCATION: PA ROUTE 188, SHPPINGPORI', PA, 15077 MCNTORING PERIOD Permit Expires: 12/27/2008 STAGE: Flnal Bftuent YEAR MO MY YEAR MO MY Permit Application Due: _Ofl_30f_2008 FROM 2020 11 01 TO 2020 11 30 No Discharge: D PARAMETER QUANTITY OR LOADING QUANTITY OR CONCENTRATION SAMPLNG FREQUENCY SAMPLNG TYPE SAMPLE MEASUREMENT VALUE VALUE UNITS VALUE 7,1 VALUE VALUE UNITS pH(00400) 7,8 1/week Grab PERMIT REQUREMeNT AO 9,0 8.U.

SAMPLE IVEASUREt,ENT *..-. - ...... nt!Vin IMAX -- 1/week Grab Total Suspended Solids (00530)

PERMIT REQUREMENT SAMPLE MEASUREMENT "9.4 30.0 AwMo 1U 100,0 DallvMI,(

"9'L 1/W!Nlk 1/week Grab Grab QI and Qease (00556)

PERMIT REQUREMENT "5.1 1~

<5.2 20 "11J'L 1/week Grab Fl<7N (50050)

SAMPLE MEASUREMENT PERMIT REQUREMENT

.002 Mcntor&R,po rt AIGMo

.002 Mor1to,- " R,port Ml/Me,(

MGO

-- - -- Aw*Mo Dallv~ 1/week 1/week 1/week Grab Estimate Estimate Facility Comments Privacy Polley I Security Polley Copyright ©2016 Corrmonwealth of Pennsylvania. All Rights Reserved

3800-FM-BC\W46212/2016 COMMO NWEALTH OF PENNSY LVANIA DEPART MENT OF ENVIRONMENTAL PROTEC TION pennsylvania BUREAU OF CLEAN WATER

  • DEPARTMENT OF ENVIRONMENTAL PROTECTION DISCHARGE MONITORING REPORT (OMR)

NAME: ENERGY HARBOR NUCLEAR OORP Reporting Frequency: _

M_onthl_Y_ _ _ __ __ _ _ _ __

ADDRESS : 78 S MAIN ST, AKRON, OH , 44308 i---P_PA002Sf ERMIT

_ tUJBE

_ 1_s_R_-11 1-t-- 0UTF:

- -ALL

- 401

_t0,1B

__ER_--1 DMR Effective From: 1110112020 FACLITY: FIRSTBBGV BEAVER VM.ilX POWER STATION 1 DMR Effective To:

-11/3CW2020 LOCATION : PA ROUTE 168, SHPPINGPORY', PA , 15077 MON'TORtlG PERIOD Permit E,cpire11: 12/%7/7:008 STAGE: Final Blluent YEAR MO DAY YEAR MO DAY Permit Application Due: 06'3CW7:008 FROM 2020 11 01 10 2020 11 30 No Discharge:

-D ---- ---- ---- -

=--- ---- ---- ---

PARAMETER QUANTilY OR LOADING QUANTilYORCONCENTRATION VALUE SAMPLING FREQUENCY SAMPLNG TYPE SAMPLE MEASUREMEM' VALUE

... UNITS VALUE VALUE 7,6

- VALUE UNITS pH(00400)

PERMTREQ!JJEENT SAMPLE MEASUREMENT

-- -- 6,0 lnlt'Mn -

6,25 -**

8.0 MoritQrJRepolt tMX s,u, 2/'1101'(h 2/monlh Grab Grab Total Suspended Solids (00530)

PERMT REQURe.£NT ... ...  ;!0.0 7.0 100:0 mg'L 2/monlh Grab Oil and Grease (00556)

SAMPLE MEASUREMENT PERMTREQUREM!NT

- -- -- A\gMo

<5.1 15

[)ally 1\,111)(

<5.1

~ mg'L 2/month 2/monlh Grab Grab Flow (50050)

SAMPLE MEASUREt/ENT PERMT REQURe.£NT

.001 Moritor&Rlpcrl Ava Mo

,001 Morftcr&Report DlllllvMm<

MGO

-- -... A!GMo

,DlllvMID( 2/month 1/week 11wNk Grab Ettlmate Estimate Facility Comments Prtvacy Polley I Secunty Polley Copyright ~2016 Cormionwealth of Pennsyfvanla. All RJohtl Reserved

3800-FM-BC\W46212/2016 COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF ENVIRONMENTAL PRo-TECTION pennsylvania BUREAU OF CLEAN WATER

  • fillii!I

~ DEPARTMENT OF ENVIRONMENTAL PROTECTION DISCHARGE MONITORING REPORT (DMR)

NAME: at:RGYHARBOR NUCLEAR CORP Reporting Frequency. Monthly ADDRESS: 76 S MAIN ST, AKRON, OH, 44308 __PERMrT_P_A002581_NJV

__5_R BE _ __,I f-l-OUTF--ALL.-403_"' __ -JIBER

.- - t DMR Effectiw From: 11/01/2020 FACLITY: FIRSTENERGY BEAVER V/IUEf POWER STATION 1 DMR Effective To: 11/3Clf2020 LOCATION: PA ROUTE 168, SHPPINGPORT, PA, 15077 MONTORN.. PERIOD Permit Expires: 17/%1/2008 STAGE: Final Blluent YEAR MO DAV YEAR MO DAV Permit Application Due: _ot1_3Clf_200e FROM 2020 11 01 'TO 2020 11 30 No Discharge:

PARAMETER QUANTITY OR LOADING QUANTITY OR CONCENTRATION SAMPLING FREQUENCY SAMPLING TYPE VALUE VALUE UNITS VALUE VALUE VALUE UNITS SAMPLE MEASUREMENT pH(00400)

PERMT REQUIREMENT

-- 8.0 9.0 s.u.

1/Wllk ln!atMn 1.t.W< Grab SAMPLE MEASUREMENT - -*-

Total Suspended Solids (00530)

PERMT REQUIREMENT

- -- 30.0 100,0 "9'L AIGMo l'WvMa,( 1/Wllk Grab SAMPLE MEASUREMENT Oil a n d ~ (00556)

PERMT REQUIREWENT

- -- 15 20 "9'L

- AIGMo Cllllv MaK 1/WNk Grab SAMPLE MEASUREMENT Ammona-/lltrogen (00610)

PERMT REQUIREMENT

- -- Meritor & *Report Mcritor&Rapclt

....., "l>'L AIGMo 1/Mek Grab SM1PLE MEASUREP.ENT Oamtrol CT-1 (04251)

PERMT REQUIREMENT

- -- .001 .001 "VL Dally w,en Dactwglng 24-H- Car4>osite SM1PLE MEASI.R:MENT AIGMo l"WvMax Flow (50050)

PERMT REQUIREMENT SM1PLE MEASUREP.ENT Morita & Report A10Mo Mentor & Report Dl!iih/Ma,c:

MGD

-- - - 1/v,eek Estimate Total Resl<lJal a-.lorlne (1RC) (50060)

PERMIT REQUIREMENT

- - - ,5 AIGMo 1.25 IMAX "l>'L 1/Wllk Grab Privacy Polley I Security Polley COpy~ht t;>2016 Corrmonwealth of Penn1ytvanla. All ~ght1 ReHrvod

3~FM-BC\W462 12/2016 COMMONWEA LTH OF PENNSYLVANIA DEPARTMENT OF ENVIRONMENTAL PROTECTION pennsylvania BUREAU OF CLEAN WATER DEPARTMENT OF ENVIRONMENTAL

  • PROTECTION DISCHARGE MONITORING REPORT (DMR)

QUANTITY OR LOADING QUANTITY OR CONCENTRATION PARAMETER SAMPLING FREQUENCY SAMPLNG TYPE Hyctazine (81313)

SAAPI.EMEAS~M ENT PERMT REQUREMENT VALUE VALUE UNITS VALUE

-- VALUE

,001 VALUE

,001 UNITS IT1l)'L 1/\wllk Grab A1aMo .D11llvMID<

Facility Comments Plfvacy Polley I S curtty Polley Copyrtght ~2016 Corrmonwealth of Penntylvanla, All Right* Reterved

3800-FM-BC\W462 12/2016 COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF ENVIRONMENTAL PROTECTION pennsylvania BUREAU OF CLEAN WATER

  • -ratJ DEPARTMENT OF ENVIRONMENTAL PROTECTION DISCHARGE MONITORING REPORT (DMR)

NAME: e.ERGYHARBOR NUCLEAR CORP Reporting Frequency. Monthly

_ _PERMIT

_ PA00258

_ 1\U.18E

_ 1_5_R_ -II I-I- OUTF

- -AI.L

- 4_111U18

_3 __ ER_ _

ADDRESS: 76 S MAIN ST, Al<A0N, OH , 44308 OMR Effective From: 11/01/2020 FACLITY: FIRS11311RGV BEAVER V/IUEf POWER STATION 1 OMR Effective To: 11/30t'2020 LOCATION: PA R0UTc 168, SHPPINGPORT', PA , 15077 MCNTORNG PERIOD Permit Expires: 12/'ZT/'lDOa STAGE: Final Blluent YEAR MO MY VEAR MO DAY Permit Application Due: _ot1_30t'

_ 'lDOa FROM 2020 11 01 TO 2020 11 30 No Oi,eharge; PARAMETER QUANTITY OR LOAONG QUANTITY OR CONCENTRATION SAMPLNG FREQUENCY SAMPLNG TYPE VALUE VALUE UNITS VALUE VALUE VALUE UNITS SMPLE MEAS~NT pH(00400)

PERMT REQURE;J.ENT 8.0 9,0 s.u.

SAMPLE MEASUREMENT

-- -- ntMn

- IMAX 1/week Grab Total Suspended Solids (00530)

PERM'TREQUREMENT

-- 30.0 100.0 mgL 1/week

- AIOMo DallvMIK Grab SMPLE MEASUREMENT Oil and Gmase (00556)

PERM'T RECIURa,ENT SMPLE M:ASUREMENT

- -- - 15 AIOMo 20 Dallv Ml,(

mgL 1/Yieek Grab Aow(50050)

Facility Comments PERMT REQUREMENT Meritor & Report AIOMo Meritor & Report DallvMa,c MGO

- - - 2/ma1h Estimate Prtvacy Polley I Security Polley Copyrtght ©2016 Corrmonwealth of Pennsylvania, All Rights Reserved

3800-FM-BC\W462 12/2016 COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF ENVIRONMENTAL PROTECTION pennsylvania BUREAU OF CLEAN WATER

  • rJl/!j jliji!I DEPARTMENT OF ENVIRONMENTAL PROTECTION DISCHARGE MONITORING REPORT (DMR)

NAME: 91:RGYHARBOR NUCLEAR CORP Reporting Frequency: _Monthl

_ _Y_ _ _ _ _ _ _ _ _ _ __

_ __ PA0025e_

. __ 1_s_ _, ~ -- -501-- ---t ADDRESS: 76 S MAIN ST, Al<R:>N, OH , 44308 OMR Effective From:

FACLITY: RRSTeaGY BEAVER V/IL!Ef POWER STATION 1 PERMIT lllMBER . . OUTFAll "'"13ER OMR Effective To:

1110112020 11/30(2020 LOCATION: PA ROUTc 168, SHPPINGPORT, PA, 15077 MONTORING PERIOD Permit Expires: 1:l/%712006 STAGE: Final Blluent YEAR MO DAY YEAA MO DAY Permit Application Due: Olli30f200S FROM 2020 11 01 TO 2020 11  ;,o No Oi1charge:

~

QUANTITY OR LOAD NG QUANTITY OR CONCENTRATION PARAMETER SAMPLNGFREQUENCY SAMPLNG TYPE VALUE VALUE UNITS VALUE VALUE VALUE UNITS SAMPLE MEASl,ff;ME.NT Total Suspended Solids (00530) 30.0 PERMITREQUREMENT 100,0 "9'L 1/W!lllk Grab SAMPLE MEASl,ff;MENT

-- - AYJMo Dl!iif M!D(

Ac,,v (50050)

Facility Comments PERMIT RECUREMENT Morita&Repat A1gMo Mentor & Repat DailvMa,c MGD

- 1/Y.eek Estimate COMMENT DETALS I COMMENTS OPERATOR NAME OPERATOR CERTIFICATION NUMBER OPERATOR CONTACT NUMBER Privacy Polley I Security Polley Copyrtght ©2016 Corm-cnwealth of Pennsylvania, All Rights Reserved

3800-FM-BC\W462 12/2016 COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF ENVIRONMENT AL PROTECTION pennsylvania BUREAU OF CLEAN WATER

  • ,lai!f

~ DEPARTMENT OF ENVmONMENTAL PROTECTION DISCHARGE MONITORING REPORT (DMR)

NAME: ENERGY HARBOR NUCLEAR CORP ADDRESS: 76 S MAIN ST, AKRON, OH, 44308

__P_ERM_P_~_M.MBER_1_,

__ I 1-1-0VTF--AU.-001_Nl.fl8

__ER __

Reporting Frequency.

Quarterty FACILITY: RRSTel:RGY BEAVER VAU.EY POWER STATION 1 0 MR Effective From:

DMR Effective To:

10,0112020 12/31/2020 LOCATION: PA ROUTE 168, SHPPINGPORT, PA, 15077 MONTORING PERIOD Permit Exs,ires: 12/27/.2008 STAGE: Flnal Blluent VEAR MO MY YEAR MO MY Permit Application Due: CMl(30f20CIS FROM 20ZD 10 01 TO 2020 12 31 No Discharge:

~

QUANTITY OR LOAD NG QUANTITY OR CONCENTRATION PARAMETER SAMPLING FREQUENCY SAMPLNGnPE VALUE VALUE UNITS VALUE VALUE VALUE UNITS SAMPLE IVEASUREMENT Iron, Total (01045)

PERMT REQURe.ENT SAMPLE MEASu:e.ENT --

Morit0r & Report Dlilv MaK

-- nvL 1/quarter Grab 21nc, Total (01092)

Facility Comments PERMIT RECIUREMENT - - - Monitor&Repc,rt C\ilvMax - nv'L 1/~er Grab Privacy Polley I Security Polley Copyright ©2016 Cornronwealth or Pennsylvania. All Rights Reserved

3800-FM-BC\W462 12/2016 COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF ENVIRONMENTAL PROTECTION pennsylvania BUREAU OF CLEAN WATER f~

  • lliil!I OEPART1'1ENT OF ENVIRONMENTAL PROTECTION DISCHARGE MONITORING REPORT (DMR)

NAME: ENERGY HARBOR NUCLEAR CORP 11 RePortlng Frequency: Qulrwl1y ADDRESS: 78 8 MAIN ST, Al<R0N, OH , 44309 t---PERM

- "-~ - -

PU.18E

- -R- -tl 1-l- ~- -AU.

-ON_M.MJ

__ER_ --l OMR Effective From: 10(01/2020 FACLITY: flRSTBEROYBEAVERVAUEYPOWl!RSTATION 1 OMR Effective To; 12/31/2020 LOCATION: PA ROUTE 188, SHPPINOPORr, PA, 15077 MONTORN3 PERIOD Permit Expires: _121_1:T,_1_200&

STAGE: Final Blluent YEAR MO DAY VEAR MO DAV Permit Application Due: _Ofl_'JIJ/_2006 FROM 2020 10 01 'TO 2020 12 31 No Discharge:

QUANTITY OR LOAONG QUANTITY OR CONCENTRATION PARAMETER SAMPLING FREQUENCY SAMPLNG TYPE VALUE VALUE uNrrs VALUE VALUE VALUE UNrTS SAMPLE MEASLRMEIIIT'

- 3.0 1/ntJlll'hlr Grab I

Ira,, Total (01045)

PERMIT RECIUREMEIIIT'

-- -- - Mcnlcr '&Report "l>'L 1/qiater Grab Zinc, Total (01092)

SAMPLE MEASLRMEIIIT' PERMIT RECIUREMEIIIT'

-- Dlilv 'Ma,c

_740

  • Monitor&R,iport ... mi>'L 1/mater 1/qiater Grab Grab Daily MID<

Facility Comments Privacy Polley I Security Polley Copyright © 2016 Corrmonwealth of Pennsylvania. Alf Rights Reserved

3800-l<M-BC\W462 12/2016 COMMONWEA LTH OF PENNSYLVAN IA DEPARTMENT OF ENVIRONMENT AL PROTECTION pennsylvania BUREAU OF CLEAN WATER f~

  • lllii!!I DEPARTMENT OF ENVIRONMENTAL PROTECTION DISCHARGE MONITORING REPORT (DMR)

NAME: EtERGY HARBOR NUCLEAR CORP Reporting Frequency. Quarterly ADDRESS: 76 S MAIN ST, AKRON, OH, 44308 .,..__PERM

_ PA0025e

_rr_ N.WE _ 1_, _R _-il i-l- OVTF- -ALL - ooe

_l'UIS

__ER_--t DMR Effective From: 10(01/2020 FACLITY: RRS'TBBGY BEAVER VMJ..EY POWER STATION 1 DMR Effective To: 12131/2020 LOCATION: PA ROUTE 188, SHPPINGPORT', PA, 15077 MONTCRNG PERICO Permit E,cplres: 12/%7/200&

STAGE: Flnal Blluent VEAR MO DAV YEAR MO DAV Permit Application Due: 08(30(200&

FROM 2020 10 01 10 2020 12 31 No Discharge:

PARAMETER 01:'ANTITY OR LOAD NG QUANTITY OR CONCENTRATION SAMPLING FREQUENCY SAMPLNG TYPE VALUE VALUE VALUE UNrrs VALUE SAMPLE MEASUREMENT" - ,750 VALUE UNITS 1/l'IUl!lter Iron, Total (01045) Grab PERMIT REQUREMENr Mor1it<¥" & 'Report "l>'I.

SAMPLE MEASUREMENT"

-- ... OlilvMllx 1/quarter Grab

.052 1/auarter Grab Zinc, Total (01092)

Facility Comments PERMIT RECIUREMENr Moritclr&Repc,rt CallvMllx - rrg'L 1/quarter Grab

}i I COMMENT DETALS

_..;.c;_;o;.;.M;.;.M..;;E;.;.;NTS;..;...;;..._....1-_ _..;;o..;.P.;;;.E..;;RA..;.r;..;o..;.R;.;.NA;;.;;.;.M;;;;;e_ _....1.,_ _ _ _ _.;.o.;..PE;;.;RA,.;.,.;.;T.;;;.o.;..;R_c.;.E_RTI_F L..I

...te

...A_TIO,.;;_N_N..;;u..;.M.e..

e....

R_ _ _ _ _..._______ o_PE_RA_r_o_R_c_oNT_A_c_r_N_uM_e_E_R_ _ _ _ _ i:

i jl * ,

Privacy Polley I Securtty Polley Copyrtght ~2016 Cormionwealth or Pennsylvanla. All Rights R.ese,-.,ed

3800-FM-WSFR0189 1~ pennsylvan1a Rev. 3/2009 COMMONWEALTH OF PENNSYLVANIA

-

  • DEPARTMENT OF ENVIRONMENTAL PROTECTION suREAu oF wATER sTANDARDs AND FAc1urv REGULATION

~ DEPARTMENT OF ENVIRONMENTAL PROTECTION SUPPLEMENTAL LABORATORY ACCREDITATION FORM 1 Permittee Name: Energy Harbor Nuclear Operating Company Address: P.O. Box 4 Shippingport, PA 15077 Beaver Valley Power Station PERMIT NUMBER MONITORING PERIOD Year/Month/Day PA0025615 2020 I 11 I 01 I TO I 2020 I 11 I 30 PARAMETER ANALYSIS METHOD LAB NAME LAB ID NUMBER2 Zinc EPA 200.7 Rev 4.4 Test America-Pittsbur gh Lab 02-00416 Copper EPA 200.7 Rev 4.4 Test America-Pittsbur gh Lab 02-00416 Iron EPA 200.7 Rev 4.4 Test America-Pittsbur gh Lab 02-00416 Chromium EPA 200.7 Rev 4.4 Test America-Pittsbur gh Lab 02-00416 Ammonia SM 4500 NH3 F Test America-Pittsbur gh Lab 02-00416 Cyanide SM 4500-CN E Test America-Pittsbur gh Lab 02-00416 Chlorobenzene EPA 624 Test America-Pittsbur gh Lab 02-00416 Oil and Grease EPA 1664 Rev A Test America-Canton Lab 68-00340 Copper EPA200.8 Test America-Pittsbur gh Lab 02-00416 Total Dissolved Solids (TDS) SM 2450 C Test America-Pittsbur gh Lab 02-00416 Oil and Grease EPA 1664 Rev B Test America-Pittsbur gh Lab 02-00416

  • 2012 EPA Method Update Rule (MUR) no longer cites Standard Method editions I certify under penalty of law that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information , the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibly of fine and imprisonment for knowing violations.

tive Officer or Name/Title Principal Executive Officer Phone: 724-682-7773 nt Matthew J . Enos General Plant Manager Date: i'2 /'Z-"l,-/2..cft.-V 1

Submit this form with the first Discharge Monitoring Report (DMR), Annual Report or Recordkeeping e mg Form, where sample results are submitted to the Department for compliance purposes. You do not need to send this form to the Department again UNLESS there has been a change to the lab or method of analysis.

2 For parameter(s) covered under accreditation-by-rule, submit the lab's registration number in lieu of an accreditation number.

3800-FM-WSFR0189 Rev. 3/2009 COMMONWEALTH OF PENNSYLVANIA

~

I~

';ii pennsylvan1a DEPARTMENT OF ENVIRONMENTAL PROTECTION DEPARTMENT OF ENVIRONMENTAL PROTECTION BUREAU OF WATER STANDARDS AND FACILITY REGULATION SUPPLEMENTAL LABORATORY ACCREDITATION FORM 1 Permittee Name: Energ:i Harbor Nuclear Oi;1erating Comi;1an:i Address: P.O . Box4 Shii;1i;1ingi;1ort, PA 15077 Beaver Valle:i Power Station PERMIT NUMBER MONITORING PERIOD Year/Month/Day PA0025615 2020 I 11 I 01 I TO I 2020 I 11 I 30 PARAMETER ANALYSIS METHOD LAB NAME LAB ID NUMBER2 Total Residual Chlorine SM 4500-CL G [20th) Beaver Valley Power Station 04-2742 Free Available Chlorine SM 4500-CL G [20th) Beaver Valley Power Station 04-2742 pH SM 4500-H+ B [20th ) Beaver Valley Power Station 04-2742 Temperature SM 2550 B [201h] Beaver Valley Power Station 04-2742 Flow NA Beaver Valley Power Station 04-2742 Total Suspended Solids (TSS) SM 2540 D [20th] Beaver Valley Power Station 04-2742 Quaternary Amine Compounds Photometric Determination Beaver Valley Power Station 04-2742 1/2-CHM-ANA-4.23H Bentonite Detoxicant Estimated using feed rate Beaver Valley Power Station 04-2742 and discharge flow rate per NPDES Permit PA0025645 Hydrazine ASTM 01385-01 Beaver Valley Power Station 04-2742 I certify under penalty of law that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system , or those persons directly responsible for gathering the information , the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information , including the possibly of fine and imprisonment for knowing violations.

Name/Title Principal Executive Officer Signature of Principal Executive Officer or Phone: 724-682-7773 A

  • gent Matthew J. Enos General Plant Manager Date: _ _ ~_z.. /_z...t...~/'ZA_-Z...O 1 Submit this form with the first Discharge Monitoring Report (DMR) , Annual Report or Recordkeeping and R rting Form, where sample results are submitted to the Department for compliance purposes. You do not need to send this form to the Department again UNLESS there has been a change to the lab or method of analysis.

2 For parameter(s) covered under accreditation-by-rule, submit the lab's registration number in lieu of an accreditation number.