MONTHYEARL-23-267, Submittal of Discharge Monitoring Report (Npdes), Permit No. PA00256152023-12-18018 December 2023 Submittal of Discharge Monitoring Report (Npdes), Permit No. PA0025615 L-23-229, Request for Additional Information Regarding the Spring 2023 Generic Letter 95-05 Voltage-Based Alternate Repair Criteria and Steam Generator F-Star Reports2023-11-29029 November 2023 Request for Additional Information Regarding the Spring 2023 Generic Letter 95-05 Voltage-Based Alternate Repair Criteria and Steam Generator F-Star Reports L-23-247, Discharge Monitoring Report (NPDES) Permit No. PA00256152023-11-17017 November 2023 Discharge Monitoring Report (NPDES) Permit No. PA0025615 L-23-227, Discharge Monitoring Report (NPDES) Permit No. PA0025615 for Third Quarter 20232023-10-20020 October 2023 Discharge Monitoring Report (NPDES) Permit No. PA0025615 for Third Quarter 2023 L-23-208, Submittal of Discharge Monitoring Report Cnpdes), Permit No. PA00256152023-09-14014 September 2023 Submittal of Discharge Monitoring Report Cnpdes), Permit No. PA0025615 L-23-167, Twenty-Third Refueling Outage Inservice Inspection Summary Report2023-09-13013 September 2023 Twenty-Third Refueling Outage Inservice Inspection Summary Report L-23-205, Supplement to Application for Order Consenting to Transfer of Licenses and Conforming License Amendments2023-09-12012 September 2023 Supplement to Application for Order Consenting to Transfer of Licenses and Conforming License Amendments L-23-172, Quality Assurance Program Manual2023-08-31031 August 2023 Quality Assurance Program Manual L-23-188, Energy Harbor Nuclear Corp., Supplement to Application for Order Consenting to Transfer of Licenses and Conforming License Amendments2023-08-0707 August 2023 Energy Harbor Nuclear Corp., Supplement to Application for Order Consenting to Transfer of Licenses and Conforming License Amendments L-23-179, Submittal of Discharge Monitoring Report, (NPDES) Permit No. PA00256152023-07-18018 July 2023 Submittal of Discharge Monitoring Report, (NPDES) Permit No. PA0025615 L-23-165, Discharge Monitoring Report (NPDES) Permit No. PA00256152023-06-26026 June 2023 Discharge Monitoring Report (NPDES) Permit No. PA0025615 L-23-139, Response to Request for Additional Information Regarding Fall 2022 180-Day Steam Generator Tube Inspection Report2023-06-13013 June 2023 Response to Request for Additional Information Regarding Fall 2022 180-Day Steam Generator Tube Inspection Report L-23-055, Submittal of the Updated Final Safety Analysis Report, Revision 342023-05-23023 May 2023 Submittal of the Updated Final Safety Analysis Report, Revision 34 L-23-065, Annual Financial Report2023-05-22022 May 2023 Annual Financial Report L-23-137, Discharge Monitoring Report (NPDES) Permit No. PA00256152023-05-18018 May 2023 Discharge Monitoring Report (NPDES) Permit No. PA0025615 L-23-125, Cycle 24 Core Operating Limits Report2023-05-17017 May 2023 Cycle 24 Core Operating Limits Report L-23-132, Response to NRC Regulatory Issue Summary 2023-01 Preparation and Scheduling of Operator Licensing Examinations2023-05-10010 May 2023 Response to NRC Regulatory Issue Summary 2023-01 Preparation and Scheduling of Operator Licensing Examinations L-23-129, Response to Request for Additional Information for 10 CFR 50.55a Request 2-TYP-4-RV-06 for Alternative Repair Methods for Reactor Pressure Vessel Head Penetrations2023-05-0505 May 2023 Response to Request for Additional Information for 10 CFR 50.55a Request 2-TYP-4-RV-06 for Alternative Repair Methods for Reactor Pressure Vessel Head Penetrations L-23-115, Submittal of 2022 Annual Radioactive Effluent Release Report, 2022 Annual Radiological Environmental Operating Report, and 2022 Annual Environmental Operating Report (Non-Radiological2023-04-27027 April 2023 Submittal of 2022 Annual Radioactive Effluent Release Report, 2022 Annual Radiological Environmental Operating Report, and 2022 Annual Environmental Operating Report (Non-Radiological L-23-126, Discharge Monitoring Report (Npdes), Permit No. PA00256152023-04-22022 April 2023 Discharge Monitoring Report (Npdes), Permit No. PA0025615 L-23-053, 2022 Annual 10 CFR 50.46 Report of Changes to or Errors in Emergency Core Cooling System Evaluation Models2023-04-14014 April 2023 2022 Annual 10 CFR 50.46 Report of Changes to or Errors in Emergency Core Cooling System Evaluation Models L-23-061, Submittal of the Decommissioning Funding Status Reports2023-03-31031 March 2023 Submittal of the Decommissioning Funding Status Reports L-23-058, 180-Day Steam Generator Tube Inspection Report2023-03-27027 March 2023 180-Day Steam Generator Tube Inspection Report L-23-066, Annual Notification of Property Insurance Coverage2023-03-21021 March 2023 Annual Notification of Property Insurance Coverage L-23-036, Report of Facility Changes, Tests and Experiments2023-03-13013 March 2023 Report of Facility Changes, Tests and Experiments L-23-086, Response to Request for Additional Information for Emergency License Amendment Request for Technical Specification 3.5.2 Regarding One-Time Action for Valve Leak Repair2023-03-0404 March 2023 Response to Request for Additional Information for Emergency License Amendment Request for Technical Specification 3.5.2 Regarding One-Time Action for Valve Leak Repair L-23-087, Supplement to Emergency License Amendment Request for Technical Specification 3.5.2 Regarding One-Time Action for Valve Leak Repair (L-2023-LLA-0027)2023-03-0404 March 2023 Supplement to Emergency License Amendment Request for Technical Specification 3.5.2 Regarding One-Time Action for Valve Leak Repair (L-2023-LLA-0027) L-23-073, Emergency License Amendment Request for Technical Specification 3.5.2 Regarding One-Time Action for Valve Leak Repair2023-03-0101 March 2023 Emergency License Amendment Request for Technical Specification 3.5.2 Regarding One-Time Action for Valve Leak Repair L-23-016, Twenty-Eighth Refueling Outage Inservice Inspection Summary Report2023-02-21021 February 2023 Twenty-Eighth Refueling Outage Inservice Inspection Summary Report L-23-064, Discharge Monitoring Report, (NPDES) Permit No. PA00256152023-02-21021 February 2023 Discharge Monitoring Report, (NPDES) Permit No. PA0025615 L-23-057, Energy Harbor Nuclear Corp Retrospective Premium Guarantee2023-02-20020 February 2023 Energy Harbor Nuclear Corp Retrospective Premium Guarantee L-22-193, Request for Exemption from Specific Provisions in 10 CFR 50 Appendix H2023-02-14014 February 2023 Request for Exemption from Specific Provisions in 10 CFR 50 Appendix H L-22-286, Supplement to Request for an Amendment to Consolidate Fuel Decay Time Technical Specifications in a New Limiting Condition for Operation Titled Decay Time2023-02-14014 February 2023 Supplement to Request for an Amendment to Consolidate Fuel Decay Time Technical Specifications in a New Limiting Condition for Operation Titled Decay Time L-23-032, Discharge Monitoring Report (NPDES) Permit No. PA0025615 for Second Half of 20222023-01-23023 January 2023 Discharge Monitoring Report (NPDES) Permit No. PA0025615 for Second Half of 2022 L-22-281, Discharge Monitoring Report (NPDES) Permit No. PA00256152022-12-16016 December 2022 Discharge Monitoring Report (NPDES) Permit No. PA0025615 L-22-246, Response to Request for Additional Information Regarding a Request to Consolidate Fuel Decay Time Technical Specifications to New LCO2022-12-0707 December 2022 Response to Request for Additional Information Regarding a Request to Consolidate Fuel Decay Time Technical Specifications to New LCO L-22-217, Submittal of Discharge Monitoring Report (NPDES) Permit No. PA00256152022-11-21021 November 2022 Submittal of Discharge Monitoring Report (NPDES) Permit No. PA0025615 L-22-226, Emergency Preparedness Plan2022-11-0404 November 2022 Emergency Preparedness Plan L-22-222, Cycle 29-1 Core Operating Limits Report2022-10-31031 October 2022 Cycle 29-1 Core Operating Limits Report L-22-228, Independent Spent Fuel Storage Installation Changes, Tests, and Experiments2022-10-26026 October 2022 Independent Spent Fuel Storage Installation Changes, Tests, and Experiments L-22-200, Response to Request for Additional Information Regarding a 180-Day Steam Generator Tube Inspection Report Fall 2021 Refueling Outage2022-10-21021 October 2022 Response to Request for Additional Information Regarding a 180-Day Steam Generator Tube Inspection Report Fall 2021 Refueling Outage L-22-232, Withdrawal of a License Amendment Request Associated with Fire Protection Program Changes2022-10-21021 October 2022 Withdrawal of a License Amendment Request Associated with Fire Protection Program Changes L-22-238, Submittal of Discharge Monitoring Report (NPDES) Permit No. PA00256152022-10-20020 October 2022 Submittal of Discharge Monitoring Report (NPDES) Permit No. PA0025615 L-22-227, Revised August 2022 Outfall 003 & 004 NPDES Discharge Monitoring Report (Dmr), Revised Daily Effluent Monitoring Report Forms for Outfalls 003 & 004 and Corrective Action Letter from Eurofins2022-10-0303 October 2022 Revised August 2022 Outfall 003 & 004 NPDES Discharge Monitoring Report (Dmr), Revised Daily Effluent Monitoring Report Forms for Outfalls 003 & 004 and Corrective Action Letter from Eurofins L-22-219, Submittal of Discharge Monitoring Report (NPDES) Permit No. PA00256152022-09-26026 September 2022 Submittal of Discharge Monitoring Report (NPDES) Permit No. PA0025615 L-22-204, Submittal of Evacuation Time Estimates2022-09-0707 September 2022 Submittal of Evacuation Time Estimates L-22-137, Request for Fire Protection Program Changes2022-09-0606 September 2022 Request for Fire Protection Program Changes L-21-238, License Amendment Request for Addition of Analytical Methodology to the Core Operating Limits Report for a Full Spectrum Loss of Coolant Accident2022-08-31031 August 2022 License Amendment Request for Addition of Analytical Methodology to the Core Operating Limits Report for a Full Spectrum Loss of Coolant Accident L-22-188, Response to Request for Additional Information Regarding Steam Generator Inspection Report- Fall 2021 Refueling Outage2022-08-22022 August 2022 Response to Request for Additional Information Regarding Steam Generator Inspection Report- Fall 2021 Refueling Outage L-22-191, Spent Fuel Storage Cask Registration2022-08-17017 August 2022 Spent Fuel Storage Cask Registration 2023-09-14
[Table view] |
Text
FENOC Beaver Valley Power Station
~P. O. Box 4 FirstEnergyNuclear OperatingCompany Shippingport, PA 15077 PaulA. Harden 724-682-5234 Site Vice President Fax: 724-643-8069 August 30, 2010 L-1 0-249 10 CFR 50.55a ATTN: Document Control Desk U. S. Nuclear Regulatory Commission Washington, DC 20555-0001
SUBJECT:
Beaver Valley Power Station, Unit Nos. 1 and 2 BV-1 Docket No. 50-334, License No. DPR-66 BV-2 Docket No. 50-412, License No. NPF-73 Proposed 10 CFR 50.55a Requests (VRR2) Associated with American Society of Mechanical Engineers (ASME) Operations and Maintenance (OM) Code Case OMN-12 In accordance with 10 CFR 50.55a, FirstEnergy Nuclear Operating Company (FENOC) requests Nuclear Regulatory Commission (NRC) approval of proposed alternatives for the Beaver Valley Power Station (BVPS) Unit No.1 fourth interval Inservice Testing Program for Pumps and Valves (IST Program) and the BVPS Unit No. 2 third interval IST Program.
Position verification testing of certain air-operated valve assemblies included in the BVPS, Unit Nos. 1 and 2 IST Programs is currently performed in accordance with the frequency described in Paragraph ISTC-3700 of the ASME OM Code-2001 Edition, "Code for Operation and Maintenance of Nuclear Power Plants," with Addenda through OMb-2003. Enclosed is the proposed alternative to perform position verification testing of these air operated valve assemblies at the diagnostic test frequency described in ASME Code Case OMN-12, "Alternate Requirements for Inservice Testing Using Risk Insights for Pneumatically-and Hydraulically-Operated Valve Assemblies in Light-Water Reactor Power Plants (OM-Code 1998, Subsection ISTC)," for BVPS, Unit Nos. 1 and 2.
In support of the spring 2012 refueling outage, FENOC requests approval of the proposed requests by September 2011.
Beaver Valley Power Station, Unit Nos. 1 and 2 L-1 0-249 Page 2 There are no regulatory commitments contained in this letter. If there are any questions or if additional information is required, please contact Mr. Thomas A. Lentz, Manager -
Fleet Licensing, at 330-761-6071.
Sincerel-Paul A. Harden
Enclosure:
Valve Relief Request 2, Proposed Alternative in Accordance with 1 OCFR50.55a(a)(3)(i) cc: NRC Region I Administrator NRC Senior Resident Inspector NRC Project Manager Director BRP/DEP Site BRP/DEP Representative
10CFR 50.55a Request Number: VRR2 Proposed Alternative in Accordance with 10 CFR 50.55a(a)(3)(i)
Page 1 of 2
--Alternative Provides Acceptable Level of Quality and Safety--
1.0 ASME Code Components Affected
Air-operated valve assemblies included in the Beaver Valley Power Station (BVPS),
Unit Nos. 1 and 2 Inservice Testing (IST) Programs for Pumps and Valves that are tested in accordance with ASME OM Code Case OMN-12, "Alternate Requirements for Inservice Testing Using Risk Insights for Pneumatically-and Hydraulically-Operated Valve Assemblies in Light-Water Reactor Power Plants (OM-Code 1998, Subsection ISTC)."
2.0 Applicable Code Edition and Addenda American Society of Mechanical Engineers (ASME) Operations and Maintenance (OM)
Code-2001, with Addenda through OMb-2003 3.0 Applicable Code Requirement ISTC-3700, "Position Indication Verification," states in part, "Valves with remote position indicators shall be observed locally at. least once every 2 years to verify that valve position is accurately indicated."
4.0 Reason for Request NUREG-1482, "Guidelines for Inservice Testing at Nuclear Power Plants," Revision 1, Section 4.2.5, "Alternatives to Stroke-Time Testing," states in part, "As an alternative to
[Air Operated Valve] AOV stroke-time testing, ASME developed Code Case OMN-12,
'Alternative Requirements for Inservice Testing Using Risk Insights for Pneumatically-and Hydraulically-Operated Valve Assemblies in Light-Water Reactor Power Plants,' to provide an alternative to the Code stroke-time testing provisions." Regulatory Guide 1.1.92, "Operation and Maintenance Code Case Acceptability, ASME OM Code," allows licensees with an applicable Code of Record to implement ASME Code Case OMN-12, Revision 0 (with certain conditions) in lieu of the Code provisions for stroke-time testing.
BVPS Unit Nos. 1 and 2 have implemented ASME OM Code Case OMN-12 for certain AOVs in lieu of the stroke-time provisions specified in ISTC-5130, "Pneumatically Operated Valves." Position verification testing for these AOVs is currently required to be performed once every two years in accordance with ISTC-3700, "Position Verification Testing," which does not coincide with the periodic test frequency of paragraph 4.2.2 under OMN-12. Performing position verification testing when maintenance personnel are at the valve locally performing diagnostic testing in accordance with OMN-12.will reduce personnel radiation exposure.
"- 1' *Page 2 of 2 5.0 Proposed Alternative and Basis for Use The AOV verification testing as described by ISTC-3700, "Position Verification Testing,"
will be performed at the AOV diagnostic test frequency specified in ASME Code Case OMN-12, Paragraph 4.2.2, "Periodic Test Requirements," in lieu of the frequency specified in ISTC-3700. ASME has determined that the diagnostic test frequency specified in OMN-12 is sufficient to ensure the capability of the valve to perform its intended function. Implementation of the ASME Code Case OMN-12 diagnostic test frequency in lieu of the frequency specified in ISTC-3700 provides an acceptable level of quality and safety for the determination of accurate valve position indication and operational readiness.
Furthermore, in accordance with ISTC-3310, "Effects of Valve Repair, Replacement, or Maintenance on Reference Values," if a maintenance activity that has the potential to affect position indication is performed between diagnostic tests, then position verification testing will be performed as a post-maintenance test regardless of the frequency determined by OMN-12.
6.0 Duration of Proposed Alternatives The proposed alternative identified in this relief request shall be utilized during the remainder of the BVPS Unit No. 1 fourth 10-Year Inservice Test Interval and the remainder of the BVPS Unit No. 2 third 10-Year Inservice Test Interval.
7.0 Precedent A similar request (VRR1) for motor operated valves (MOVs) was approved for the BVPS Unit No.1 fourth 10-Year Inservice Test Interval and the BVPS Unit No. 2 third 10-Year Inservice Test Interval to allow position verification testing to be performed at the OMN-1 diagnostic test frequency.
8.0 References U.S. Nuclear Regulatory Commission letter, Beaver Valley Power Station, Unit No. 1, Docket No. 50-334, Safety Evaluation for Valve Relief Request No. 1 (VRR1) for the Fourth 10-Year Interval for Pumps and Valves Inservice Testing Program (TAC Nos.
MD5118-MD5131), dated September 27, 2007.
U.S. Nuclear Regulatory Commission letter, Beaver Valley Power Station, Unit No. 2, Docket No. 50-412, Safety Evaluation for Valve Relief Request No. 1 (VRR1) for the Third 10-Year Interval for Pumps and Valves Inservice Testing Program (TAC Nos.
MD5595-MD5604), dated February 14, 2008.