Nonconforming Structural Steel for Safety-Related UseML031180606 |
Person / Time |
---|
Site: |
Beaver Valley, Millstone, Hatch, Calvert Cliffs, Dresden, Davis Besse, Peach Bottom, Browns Ferry, Salem, Oconee, Mcguire, Nine Mile Point, Palisades, Palo Verde, Perry, Indian Point, Fermi, Kewaunee, Catawba, Harris, Wolf Creek, Saint Lucie, Point Beach, Oyster Creek, Watts Bar, Hope Creek, Grand Gulf, Cooper, Sequoyah, Byron, Pilgrim, Arkansas Nuclear, Three Mile Island, Braidwood, Susquehanna, Summer, Prairie Island, Columbia, Seabrook, Brunswick, Surry, Limerick, North Anna, Turkey Point, River Bend, Vermont Yankee, Crystal River, Haddam Neck, Ginna, Diablo Canyon, Callaway, Vogtle, Waterford, Duane Arnold, Farley, Robinson, Clinton, South Texas, San Onofre, Cook, Comanche Peak, Yankee Rowe, Maine Yankee, Quad Cities, Humboldt Bay, La Crosse, Big Rock Point, Rancho Seco, Zion, Midland, Bellefonte, Fort Calhoun, FitzPatrick, McGuire, LaSalle, 05000000, 05000262, Zimmer, Fort Saint Vrain, Shoreham, Satsop, Trojan, Atlantic Nuclear Power Plant, Skagit, Marble Hill |
---|
Issue date: |
02/22/1985 |
---|
From: |
Jordan E NRC/IE |
---|
To: |
|
---|
References |
---|
IN-85-015, NUDOCS 8502200273 |
Download: ML031180606 (5) |
|
Similar Documents at Beaver Valley, Millstone, Hatch, Calvert Cliffs, Dresden, Davis Besse, Peach Bottom, Browns Ferry, Salem, Oconee, Mcguire, Nine Mile Point, Palisades, Palo Verde, Perry, Indian Point, Fermi, Kewaunee, Catawba, Harris, Wolf Creek, Saint Lucie, Point Beach, Oyster Creek, Watts Bar, Hope Creek, Grand Gulf, Cooper, Sequoyah, Byron, Pilgrim, Arkansas Nuclear, Three Mile Island, Braidwood, Susquehanna, Summer, Prairie Island, Columbia, Seabrook, Brunswick, Surry, Limerick, North Anna, Turkey Point, River Bend, Vermont Yankee, Crystal River, Haddam Neck, Ginna, Diablo Canyon, Callaway, Vogtle, Waterford, Duane Arnold, Farley, Robinson, Clinton, South Texas, San Onofre, Cook, Comanche Peak, Yankee Rowe, Maine Yankee, Quad Cities, Humboldt Bay, La Crosse, Big Rock Point, Rancho Seco, Zion, Midland, Bellefonte, Fort Calhoun, FitzPatrick, McGuire, LaSalle, 05000000, 05000262, Zimmer, Fort Saint Vrain, Shoreham, Satsop, Trojan, Atlantic Nuclear Power Plant, Skagit, Marble Hill |
---|
Category:NRC Information Notice
MONTHYEARInformation Notice 2020-02, Flex Diesel Generator Operational Challenges2020-09-15015 September 2020 Flex Diesel Generator Operational Challenges ML20225A0322020-09-0303 September 2020 NRC Choice Letter to NAC International with Attached Safety Inspection Report, IR 0721015/2020201, February 24-27, 2020 and July 22, 2020, Inspection of NAC International in Norcross, Georgia Information Notice 2012-09, PWROG-16043-NP-A, Revision 2, PWROG Program to Address NRC Information Notice 2012-09: Irradiation Effects on Fuel Assembly Spacer Grid Crush Strength for Westinghouse and CE PWR Fuel Designs.2019-11-30030 November 2019 PWROG-16043-NP-A, Revision 2, PWROG Program to Address NRC Information Notice 2012-09: Irradiation Effects on Fuel Assembly Spacer Grid Crush Strength for Westinghouse and CE PWR Fuel Designs. Information Notice 2011-20, NRC060 - NRC Information Notice 2011-20: Concrete Degradation by Alkali-Silica Reaction (Nov. 18, 2011)2019-07-24024 July 2019 NRC060 - NRC Information Notice 2011-20: Concrete Degradation by Alkali-Silica Reaction (Nov. 18, 2011) ML19196A2452019-07-15015 July 2019 Public Notice - Sequoyah Nuclear Plant, Unit 2 - Exigent Amendment to Facility Operating License Information Notice 2019-01, Inadequate Evaluation of Temporary Alterations2019-03-12012 March 2019 Inadequate Evaluation of Temporary Alterations ML16028A3082016-04-27027 April 2016 NRC Information Notice; IN 2016-05: Operating Experience Regarding Complications From a Loss of Instrumentation Air Information Notice 2015-05, Inoperability of Auxiliary and Emergency Feedwater Auto Start Circuits on Loss of Main Feedwater Pumps2015-05-12012 May 2015 Inoperability of Auxiliary and Emergency Feedwater Auto Start Circuits on Loss of Main Feedwater Pumps Information Notice 2015-05, Inoperability Of Auxiliary And Emergency Feedwater Auto Start Circuits On Loss Of Main Feedwater Pumps2015-05-12012 May 2015 Inoperability Of Auxiliary And Emergency Feedwater Auto Start Circuits On Loss Of Main Feedwater Pumps Information Notice 2013-20, OFFICIAL EXHIBIT - NYS000538-00-BD01 - NRC Information Notice 2013-20: Steam Generator Channel Head and Tubesheet Degradation (October 3, 2013) (ML13204A143)2013-10-0303 October 2013 OFFICIAL EXHIBIT - NYS000538-00-BD01 - NRC Information Notice 2013-20: Steam Generator Channel Head and Tubesheet Degradation (October 3, 2013) (ML13204A143) Information Notice 2013-20, Official Exhibit - NYS000538-00-BD01 - NRC Information Notice 2013-20: Steam Generator Channel Head and Tubesheet Degradation (October 3, 2013) (ML13204A143)2013-10-0303 October 2013 Official Exhibit - NYS000538-00-BD01 - NRC Information Notice 2013-20: Steam Generator Channel Head and Tubesheet Degradation (October 3, 2013) (ML13204A143) Information Notice 2013-11, OFFICIAL EXHIBIT - NYS000551-00-BD01 - NRC Information Notice 2013-11: Crack-Like Indication at Dents/Dings and in the Freespan Region of Thermally Treated Alloy 600 Steam Generator Tubes (July 3, 2013)2013-07-0303 July 2013 OFFICIAL EXHIBIT - NYS000551-00-BD01 - NRC Information Notice 2013-11: Crack-Like Indication at Dents/Dings and in the Freespan Region of Thermally Treated Alloy 600 Steam Generator Tubes (July 3, 2013) Information Notice 2013-11, Official Exhibit - NYS000551-00-BD01 - NRC Information Notice 2013-11: Crack-Like Indication at Dents/Dings and in the Freespan Region of Thermally Treated Alloy 600 Steam Generator Tubes (July 3, 2013)2013-07-0303 July 2013 Official Exhibit - NYS000551-00-BD01 - NRC Information Notice 2013-11: Crack-Like Indication at Dents/Dings and in the Freespan Region of Thermally Treated Alloy 600 Steam Generator Tubes (July 3, 2013) Information Notice 2010-12, Intervenors' Fifth Motion to Amend and/or Supplement Proposed Contention No. 5 (Shield Building Cracking). Appendix VI: NRC FOIA Responses (B-51 Through B-53); Turkey Point Event Report; NRC Information Notice 2010-12: Contain2012-08-17017 August 2012 Intervenors' Fifth Motion to Amend and/or Supplement Proposed Contention No. 5 (Shield Building Cracking). Appendix VI: NRC FOIA Responses (B-51 Through B-53); Turkey Point Event Report; NRC Information Notice 2010-12: Containment Liner Cor Information Notice 2010-12, Intervenors' Fifth Motion to Amend and/or Supplement Proposed Contention No. 5 (Shield Building Cracking). Appendix VI: NRC FOIA Responses (B-51 Through B-53); Turkey Point Event Report; NRC Information Notice 2010-12: Con2012-08-17017 August 2012 Intervenors' Fifth Motion to Amend and/or Supplement Proposed Contention No. 5 (Shield Building Cracking). Appendix VI: NRC FOIA Responses (B-51 Through B-53); Turkey Point Event Report; NRC Information Notice 2010-12: Containment Liner Cor Information Notice 2010-12, Intervenors' Fifth Motion to Amend And/Or Supplement Proposed Contention No. 5 (Shield Building Cracking). Appendix VI: NRC FOIA Responses (B-51 Through B-53); Turkey Point Event Report; NRC Information Notic2012-08-17017 August 2012 Intervenors' Fifth Motion to Amend And/Or Supplement Proposed Contention No. 5 (Shield Building Cracking). Appendix VI: NRC FOIA Responses (B-51 Through B-53); Turkey Point Event Report; NRC Information Notice 2010-12: Containment Liner Cor Information Notice 2012-13, Boraflex Degradation Surveillance Programs and Corrective Actions in the Spent Fuel Pool2012-08-10010 August 2012 Boraflex Degradation Surveillance Programs and Corrective Actions in the Spent Fuel Pool Information Notice 2012-13, Boraflex Degradation Surveillance Programs And Corrective Actions In The Spent Fuel Pool2012-08-10010 August 2012 Boraflex Degradation Surveillance Programs And Corrective Actions In The Spent Fuel Pool Information Notice 2012-11, Age Related Capacitor Degradation2012-07-23023 July 2012 Age Related Capacitor Degradation ML12031A0132012-02-0606 February 2012 U.S. Nuclear Regulatory Commission Investigation Report No. 2-2010-058, Cpn International, Inc Information Notice 2011-19, Licensee Event Reports Containing Information Pertaining to Defects to Basic Components2011-09-26026 September 2011 Licensee Event Reports Containing Information Pertaining to Defects to Basic Components Information Notice 2011-15, Steel Containment Degradation and Associated License Renewal Aging Management Issues2011-08-0101 August 2011 Steel Containment Degradation and Associated License Renewal Aging Management Issues Information Notice 2011-17, Calculation Methodologies for Operability Determinations of Gas Voids in Nuclear Power Plant Piping2011-07-26026 July 2011 Calculation Methodologies for Operability Determinations of Gas Voids in Nuclear Power Plant Piping Information Notice 2011-13, Official Exhibit - NYS000329-00-BD01 - NRC Information Notice 2011-13, Control Rod Blade Cracking Resulting in Reduced Design Lifetime (Jun 29, 2011) (NRC in 2011-13)2011-06-29029 June 2011 Official Exhibit - NYS000329-00-BD01 - NRC Information Notice 2011-13, Control Rod Blade Cracking Resulting in Reduced Design Lifetime (Jun 29, 2011) (NRC in 2011-13) Information Notice 2011-13, Official Exhibit - Nys000329-00-Bd01 - NRC Information Notice 2011-13, Control Rod Blade Cracking Resulting in Reduced Design Lifetime (Jun 29, 2011) (Nrc in 2011-13)2011-06-29029 June 2011 Official Exhibit - Nys000329-00-Bd01 - NRC Information Notice 2011-13, Control Rod Blade Cracking Resulting in Reduced Design Lifetime (Jun 29, 2011) (Nrc in 2011-13) Information Notice 2011-13, OFFICIAL EXHIBIT - NYS000329-00-BD01 - NRC Information Notice 2011-13, Control Rod Blade Cracking Resulting in Reduced Design Lifetime (Jun 29, 2011) (NRC in 2011-13)2011-06-29029 June 2011 OFFICIAL EXHIBIT - NYS000329-00-BD01 - NRC Information Notice 2011-13, Control Rod Blade Cracking Resulting in Reduced Design Lifetime (Jun 29, 2011) (NRC in 2011-13) Information Notice 2011-04, IN: Contaminants and Stagnant Conditions Affecting Stress Corrosion Cracking in Stainless Steel Piping in Pressurized Water Reactors2011-02-23023 February 2011 IN: Contaminants and Stagnant Conditions Affecting Stress Corrosion Cracking in Stainless Steel Piping in Pressurized Water Reactors Information Notice 2011-04, In: Contaminants and Stagnant Conditions Affecting Stress Corrosion Cracking in Stainless Steel Piping in Pressurized Water Reactors2011-02-23023 February 2011 In: Contaminants and Stagnant Conditions Affecting Stress Corrosion Cracking in Stainless Steel Piping in Pressurized Water Reactors Information Notice 2011-04, in: Contaminants and Stagnant Conditions Affecting Stress Corrosion Cracking in Stainless Steel Piping in Pressurized Water Reactors2011-02-23023 February 2011 in: Contaminants and Stagnant Conditions Affecting Stress Corrosion Cracking in Stainless Steel Piping in Pressurized Water Reactors Information Notice 2010-26, New England Coalition'S Motion for Leave to Reply to NRC Staff'S Objection to Nec'S Notification of Information Notice 2010-26 and Entergy'S Response to the Supplement to Nec'S Petition for Commission Review of LBP-10-2010-12-30030 December 2010 New England Coalition'S Motion for Leave to Reply to NRC Staff'S Objection to Nec'S Notification of Information Notice 2010-26 and Entergy'S Response to the Supplement to Nec'S Petition for Commission Review of LBP-10-19 Information Notice 2010-26, New England Coalition'S Motion for Leave to Reply to NRC Staff'S Objection to Nec'S Notification of Information Notice 2010-26 and Entergy'S Response to the Supplement to Nec'S Petition for Commission Review2010-12-30030 December 2010 New England Coalition'S Motion for Leave to Reply to NRC Staff'S Objection to Nec'S Notification of Information Notice 2010-26 and Entergy'S Response to the Supplement to Nec'S Petition for Commission Review of LBP-10-19 Information Notice 2010-26, 2010/12/21-NRC Staff'S Objection to Nec'S Notification of Information Notice 2010-262010-12-21021 December 2010 2010/12/21-NRC Staff'S Objection to Nec'S Notification of Information Notice 2010-26 ML13066A1872009-12-16016 December 2009 Draft NRC Information Notice 2009-xx - Underestimate of Dam Failure Frequency Used in Probabilistic Risk Assessments ML1007804482009-11-23023 November 2009 Email from Peter Bamford, NRR to Pamela Cowan, Exelon on TMI Contamination Control Event Information Notice 2009-11, NSP000059-Revised Prefiled Testimony of Northard/Petersen/Peterson-NRC Information Notice 2009-112009-07-0707 July 2009 NSP000059-Revised Prefiled Testimony of Northard/Petersen/Peterson-NRC Information Notice 2009-11 Information Notice 2009-10, Official Exhibit - NYS000019-00-BD01- NRC Information Notice 2009-10, Transformers Failures - Recent Operating Experience (Jul. 7, 2009) (NRC in 2009-10)2009-07-0707 July 2009 Official Exhibit - NYS000019-00-BD01- NRC Information Notice 2009-10, Transformers Failures - Recent Operating Experience (Jul. 7, 2009) (NRC in 2009-10) Information Notice 2009-09, Improper Flow Controller Settings Renders Injection Systems Inoperable and Surveillance Did Not Identify2009-06-19019 June 2009 Improper Flow Controller Settings Renders Injection Systems Inoperable and Surveillance Did Not Identify Information Notice 2008-12, Reactor Trip Due to Off-Site Power Fluctuation2008-07-0707 July 2008 Reactor Trip Due to Off-Site Power Fluctuation Information Notice 2008-11, Service Water System Degradation at Brunswicksteam Electric Plant Unit 12008-06-18018 June 2008 Service Water System Degradation at Brunswicksteam Electric Plant Unit 1 Information Notice 2008-04, Counterfeit Parts Supplied to Nuclear Power Plants2008-04-0707 April 2008 Counterfeit Parts Supplied to Nuclear Power Plants Information Notice 1991-09, Counterfeiting of Crane Valves2007-09-25025 September 2007 Counterfeiting of Crane Valves Information Notice 2007-28, Potential Common Cause Vulnerabilities in Essential Service Water Systems Due to Inadequate Chemistry Controls2007-09-19019 September 2007 Potential Common Cause Vulnerabilities in Essential Service Water Systems Due to Inadequate Chemistry Controls Information Notice 2007-29, Temporary Scaffolding Affects Operability of Safety-Related Equipment2007-09-17017 September 2007 Temporary Scaffolding Affects Operability of Safety-Related Equipment Information Notice 2007-14, Loss of Offsite Power and Dual-Unit Trip at Catawba Nuclear Generating Station2007-03-30030 March 2007 Loss of Offsite Power and Dual-Unit Trip at Catawba Nuclear Generating Station Information Notice 2007-06, Potential Common Cause Vulnerabilities in Essential Service Water Systems2007-02-0909 February 2007 Potential Common Cause Vulnerabilities in Essential Service Water Systems Information Notice 2007-05, Vertical Deep Draft Pump Shaft and Coupling Failures2007-02-0909 February 2007 Vertical Deep Draft Pump Shaft and Coupling Failures Information Notice 2006-31, Inadequate Fault Interrupting Rating of Breakers2006-12-26026 December 2006 Inadequate Fault Interrupting Rating of Breakers Information Notice 2006-29, Potential Common Cause Failure of Motor-operated Valves as a Result of Stem Nut Wear2006-12-14014 December 2006 Potential Common Cause Failure of Motor-operated Valves as a Result of Stem Nut Wear Information Notice 2006-29, Potential Common Cause Failure of Motor-operated Valves As a Result of Stem Nut Wear2006-12-14014 December 2006 Potential Common Cause Failure of Motor-operated Valves As a Result of Stem Nut Wear Information Notice 2006-13, E-mail from M. Mclaughlin on NRC, Regarding NRC Information Notice 2006-13: Groundwater Contamination2006-07-13013 July 2006 E-mail from M. Mclaughlin on NRC, Regarding NRC Information Notice 2006-13: Groundwater Contamination 2020-09-03 The following query condition could not be considered due to this wiki's restrictions on query size or depth: <code> [[:Beaver Valley]] OR [[:Millstone]] OR [[:Hatch]] OR [[:Calvert Cliffs]] OR [[:Dresden]] OR [[:Davis Besse]] OR [[:Peach Bottom]] OR [[:Browns Ferry]] OR [[:Salem]] OR [[:Oconee]] OR [[:Mcguire]] OR [[:Nine Mile Point]] OR [[:Palisades]] OR [[:Palo Verde]] OR [[:Perry]] OR [[:Indian Point]] OR [[:Fermi]] OR [[:Kewaunee]] OR [[:Catawba]] OR [[:Harris]] OR [[:Wolf Creek]] OR [[:Saint Lucie]] OR [[:Point Beach]] OR [[:Oyster Creek]] OR [[:Watts Bar]] OR [[:Hope Creek]] OR [[:Grand Gulf]] OR [[:Cooper]] OR [[:Sequoyah]] OR [[:Byron]] OR [[:Pilgrim]] OR [[:Arkansas Nuclear]] OR [[:Three Mile Island]] OR [[:Braidwood]] OR [[:Susquehanna]] OR [[:Summer]] OR [[:Prairie Island]] OR [[:Columbia]] OR [[:Seabrook]] OR [[:Brunswick]] OR [[:Surry]] OR [[:Limerick]] OR [[:North Anna]] OR [[:Turkey Point]] OR [[:River Bend]] OR [[:Vermont Yankee]] OR [[:Crystal River]] OR [[:Haddam Neck]] OR [[:Ginna]] OR [[:Diablo Canyon]] OR [[:Callaway]] OR [[:Vogtle]] OR [[:Waterford]] OR [[:Duane Arnold]] OR [[:Farley]] OR [[:Robinson]] OR [[:Clinton]] OR [[:South Texas]] OR [[:San Onofre]] OR [[:Cook]] OR [[:Comanche Peak]] OR [[:Yankee Rowe]] OR [[:Maine Yankee]] OR [[:Quad Cities]] OR [[:Humboldt Bay]] OR [[:La Crosse]] OR [[:Big Rock Point]] OR [[:Rancho Seco]] OR [[:Zion]] OR [[:Midland]] OR [[:Bellefonte]] OR [[:Fort Calhoun]] OR [[:FitzPatrick]] OR [[:McGuire]] OR [[:LaSalle]] OR [[:05000000]] OR [[:05000262]] OR [[:Zimmer]] OR [[:Fort Saint Vrain]] OR [[:Shoreham]] OR [[:Satsop]] OR [[:Trojan]] OR [[:Atlantic Nuclear Power Plant]] OR [[:Skagit]] OR [[:Marble Hill]] </code>.
[Table view]The following query condition could not be considered due to this wiki's restrictions on query size or depth: <code> [[:Beaver Valley]] OR [[:Millstone]] OR [[:Hatch]] OR [[:Calvert Cliffs]] OR [[:Dresden]] OR [[:Davis Besse]] OR [[:Peach Bottom]] OR [[:Browns Ferry]] OR [[:Salem]] OR [[:Oconee]] OR [[:Mcguire]] OR [[:Nine Mile Point]] OR [[:Palisades]] OR [[:Palo Verde]] OR [[:Perry]] OR [[:Indian Point]] OR [[:Fermi]] OR [[:Kewaunee]] OR [[:Catawba]] OR [[:Harris]] OR [[:Wolf Creek]] OR [[:Saint Lucie]] OR [[:Point Beach]] OR [[:Oyster Creek]] OR [[:Watts Bar]] OR [[:Hope Creek]] OR [[:Grand Gulf]] OR [[:Cooper]] OR [[:Sequoyah]] OR [[:Byron]] OR [[:Pilgrim]] OR [[:Arkansas Nuclear]] OR [[:Three Mile Island]] OR [[:Braidwood]] OR [[:Susquehanna]] OR [[:Summer]] OR [[:Prairie Island]] OR [[:Columbia]] OR [[:Seabrook]] OR [[:Brunswick]] OR [[:Surry]] OR [[:Limerick]] OR [[:North Anna]] OR [[:Turkey Point]] OR [[:River Bend]] OR [[:Vermont Yankee]] OR [[:Crystal River]] OR [[:Haddam Neck]] OR [[:Ginna]] OR [[:Diablo Canyon]] OR [[:Callaway]] OR [[:Vogtle]] OR [[:Waterford]] OR [[:Duane Arnold]] OR [[:Farley]] OR [[:Robinson]] OR [[:Clinton]] OR [[:South Texas]] OR [[:San Onofre]] OR [[:Cook]] OR [[:Comanche Peak]] OR [[:Yankee Rowe]] OR [[:Maine Yankee]] OR [[:Quad Cities]] OR [[:Humboldt Bay]] OR [[:La Crosse]] OR [[:Big Rock Point]] OR [[:Rancho Seco]] OR [[:Zion]] OR [[:Midland]] OR [[:Bellefonte]] OR [[:Fort Calhoun]] OR [[:FitzPatrick]] OR [[:McGuire]] OR [[:LaSalle]] OR [[:05000000]] OR [[:05000262]] OR [[:Zimmer]] OR [[:Fort Saint Vrain]] OR [[:Shoreham]] OR [[:Satsop]] OR [[:Trojan]] OR [[:Atlantic Nuclear Power Plant]] OR [[:Skagit]] OR [[:Marble Hill]] </code>. |
SSINS No.: 6835 IN 85-15 UNITED STATES
NUCLEAR REGULATORY COMMISSION
OFFICE OF INSPECTION AND ENFORCEMENT
WASHINGTON, D.C. 20555 February 22, 1985 IE INFORMATION NOTICE NO. 85-15: NONCONFORMING STRUCTURAL STEEL FOR
SAFETY-RELATED USE
Addressees
All nuclear power reactor facilities holding an operating license (OL) or
construction permit (CP).
Purpose
This information notice is provided to alert recipients of a potentially
significant problem pertaining to the structural material provided by steel
suppliers for safety-related use, especially plate that the steel suppliers cut
into small pieces. It is expected that recipients will review the information
for applicability to their facilities and consider actions, if appropriate, to
preclude a similar problem occurring at their facilities. However, suggestions
contained in this information notice do not constitute NRC requirements;
therefore, no specific action or written response is required.
Description of Circumstances
On August 3, 1984, Illinois Power Company made notification of a potentially
reportable deficiency concerning ASTM A-36 plate material. A 1/2 x 15 x 15 in.
plate of steel did not behave as expected in a mechanical cutting operation.
Subsequent testing of this plate showed that the physical properties (yield and
tensile strength) were less than that required by the A-36 material specifica- tion. Confirmatory testing of samples from other plates having the same
identification number (the material manufacturer's heat number) by a different
laboratory also showed that the yield and tensile strengths were lower than
required. For all the samples tested with this identification number, the
lowest yield strength was 14% below the ASTM minimum and 23% below the certi- fied material test report (CMTR). The lowest tensile strength was 24% below
the ASTM minimum and 34% below the CMTR. The certified material test report, which accompanied this material, came from Phoenix Steel Corporation. The
report showed that the material met the requirements of ASTM A-36 and was
manufactured in 1980.
Subsequently, Phoenix Steel performed a chemical analysis of two other samples
with the same identification number and concluded that this material was not
made by them. Phoenix Steel makes steel from scrap and the analysis of trace
chemical elements showed a purity not possible from the remelting of scrap
material. Testing of an additional sample with the same identification by an
independent laboratory confirmed this analysis.
8502200273
IN 85-15 February 22, 1985 The Illinois Power Company began a thorough examination program and discovered
a 1/2 x 10 x 10 in. steel plate with a different identification number that
also had yield and tensile strengths lower than required by the A-36 material
specification. The certified material test report, which accompanied this
material, came from Bethlehem Steel Corporation. The report showed that the
material met the requirements of ASTM A-36 and was manufactured in the last
half of 1980. Testing of an additional sample with the same identification by
an independent laboratory also showed yield and tensile strengths lower than
required. For all the samples tested with this identification number, the
lowest yield strength was 16% below the ASTM minimum and 36% below the CMTR.
The lowest tensile strength was 25% below the ASTM minimum and 45% below the
CMTR.
Neither Bethlehem Steel nor Phoenix Steel sell steel cut into small pieces. In
both cases, an independent supplier, Interstate Steel Supply Company of Phila- delphia, Pennsylvania, provided the material to Illinois Power Company.
Interstate Steel purchases plates, shapes and rectangular tubing in large
quantities from steel mills and other suppliers. The material is usually
resold, as is, to small users, but occasionally the material is cut into
smaller sizes. Interstate Steel does not have an ASME Quality System Certifi- cate, but does supply structural steel for safety-related use. The Clinton
Power Station purchased material from Interstate Steel for safety-related pipe
supports, conduit supports, beam stiffeners, and cable pan hangers.
Tr'EbiTityM o'6fCut'M'aftera'l '
Until recently, Interstate Steel had a subcontractor perform all cutting of
plate. A review of certified material test reports, shipping invoices and
purchase orders, as well as discussions with subcontractors, indicated that
traceability was not maintained when material was sent out for cutting.
Interstate Steel was unable to show that the material' that their vendor cut to
size and shipped to Clinton was the material shown on the certified material
test report.
A comparison was made between the quantities of steel listed on the certified
material test report, identified by heat number, and the quantities of steel
received by Illinois Power Company with the same heat number. There were
several instances where the quantities of cut plate shipped by Interstate Steel
exceeded the dimensional limitations of the material supplied under the same
heat number by Bethlehem Steel to Interstate Steel. The disparities have not
been resolved.
Safety-Related ASME Code Material
A review of certified material test reports, which were supplied by Interstate
Steel for material delivered after April 1982 to Clinton, revealed that Inter- state Steel purchased material from sources that were not approved to supply
ASME material, in accordance with the requirements of Subarticle NA-3700 of
Section III of the ASME Code. The testing necessary to upgrade the material, as required by Subarticle NA-3700, was not performed.
IN 85-15 February 22, 1985 Interstate Steel maintains inventory records by size, not by heat number, and
it does not retain inventory records beyond 4 years. The records do not
provide positive identification of the customers for a specific manufacturer's
heat number.
The Illinois Power Company is locating the material that is suspected of having
lower-than-specified yield and tensile strengths and is evaluating the effect
of reduced strength on safety. Further testing of material is being performed.
Interstate Steel has provided a list (Attachment 1) of the nuclear power
reactor facilities to which they have supplied material. In two instances, only the name of the utility was furnished. The list does not contain
information about the safety significance of the material.
No specific action or written response is required by this information notice.
If you have any questions about this matter, please contact the Regional
Administrator of the appropriate NRC regional office or this office.
wDirector
Divisi of Emergency Preparedness
and Engineering Response
Office of Inspection and Enforcement
Technical Contacts: P. Cortland, IE
(301) 492-4175 E. T. Baker, IE
(301) 492-4874 Attachments:
1. List of Nuclear Power Reactor Facilities
Receiving Material from Interstate Steel
2. List of Recently Issued IE Information Notices
Attachment 1 IN 85-15 February 22, 1985 LIST OF NUCLEAR POWER REACTOR FACILITIES
RECEIVING MATERIAL FROM INTERSTATE STEEL
UTILITY FACILITY
Carolina Power & Light Company Shearon Harris Nuclear Power Plant
Consumers Power Company Unknown
Duke Power Company Unknown
Duquesne Light Company Beaver Valley Power Station
Florida Power & Light Company Turkey Point Plant
Georgia Power Company Alvin W. Vogtle Nuclear Plant
GPU Nuclear Three Mile Island - 1 GPU Nuclear Three Mile Island - 2 Gulf States Utilities River Bend Station
Illinois Power Company Clinton Power Station
Long Island Lighting Company Shoreham Nuclear Power Station
Niagara Mohawk Power Company Nine Mile Point
Northeast Utilities Millstone Nuclear Power Station Unit 3 Pennsylvania Power & Light Company Susquehanna Steam Electric Station
Philadelphia Electric Company Limerick Generating Station
Philadelphia Electric Company Peach Bottom Atomic Power Station
Power Authority of the State Indian Point Nuclear Power Plant
of New York
Public Service Company of Seabrook Station
New Hampshire
Public Service Electric & Gas Hope Creek Generating Station
Company
Public Service Electric & Gas Salem Nuclear Generating Station
Company
Virginia Electric & Power Company Surry Power Station
Attachment 2 IN 85-15 February 22, 1985 LIST OF RECENTLY ISSUED
IE INFORMATION NOTICES
Information Date of
Notice No. Subject Issue Issued to
85-14 Failure of a Heavy Control 02/22/85 All power reactor
Rod (B4C) Drive Assembly facilities holding
to Insert on a Trip Signal a CP
85-13 Consequences of Using 02/21/85 All power reactor
Soluble Dams facilities holding
a CP
85-12 Recent Fuel Handling Events 02/11/85 All power reactor
facilities holding
a CP
85-11 Licensee Programs For 2/11/85 All power reactor
Inspection Of Electrical facilities holding
Raceway And Cable Installation a CP
85-10 Posttensioned Containment 2/6/85 All power reactor
Tendon Anchor Head Failure facilities holding
an OL or CP
85-09 Isolation Transfer Switches 1/31/85 All power reactor
And Post-Fire Shutdown facilities holding
Capability an OL or CP
85-08 Industry Experience On 1/30/85 All power reactor
Certain Materials Used In facilities holding
Safety-Related Equipment an OL or CP
85-07 Contaminated Radiography 1/29/85 All NRC licensees
Source Shipments authorized to
possess industrial
radiography sources
85-06 Contamination of Breathing 1/23/85 All power reactor
Air Systems facilities holding
an OL or CP
85-05 Pipe Whip Restraints 1/23/85 All power reactor I
facilities holding
an OL or CP
OL = Operating License
CP = Construction Permit
|
---|
|
list | - Information Notice 1985-01, Continuous Supervision of Irradiators (10 January 1985, Topic: Stress corrosion cracking)
- Information Notice 1985-02, Improper Installation and Testing of Differential Pressure Transmitters (11 January 1985, Topic: Stress corrosion cracking)
- Information Notice 1985-03, Separation of Primary Reactor Coolant Pump Shaft and Impeller (15 January 1985, Topic: Stress corrosion cracking)
- Information Notice 1985-04, Inadequate Management of Security Response Drills (17 January 1985)
- Information Notice 1985-05, Pipe Whip Restraints (23 January 1985)
- Information Notice 1985-06, Contamination of Breathing Air Systems (23 January 1985)
- Information Notice 1985-07, Contaminated Radiography Source Shipments (29 January 1985)
- Information Notice 1985-08, Industry Experience on Certain Materials Used in Safety-Related Equipment (30 January 1985)
- Information Notice 1985-09, Isolation Transfer Switches and Post-Fire Shutdown Capability (31 January 1985, Topic: Safe Shutdown)
- Information Notice 1985-10, Posttensioned Containment Tendon Anchor Head Failure (6 February 1985, Topic: Stress corrosion cracking)
- Information Notice 1985-11, Licensee Programs for Inspection of Electrical Raceway and Cable Installations (11 February 1985)
- Information Notice 1985-12, Recent Fuel Handling Events (11 February 1985, Topic: Eddy Current Testing)
- Information Notice 1985-13, Consequences of Using Soluble Dams (21 February 1985, Topic: Hydrostatic)
- Information Notice 1985-14, Failure of a Heavy Control Rod (B4C) Drive Assembly to Insert on a Trip Signal (22 February 1985)
- Information Notice 1985-15, Nonconforming Structural Steel for Safety-Related Use (22 February 1985)
- Information Notice 1985-16, Time/Current Trip Curve Discrepancy of ITE/Siemens-Allis Molded Case Circuit Breaker (27 February 1985)
- Information Notice 1985-17, Possible Sticking of Asco Solenoid Valves (1 March 1985)
- Information Notice 1985-18, Failures of Undervoltage Output Circuit Boards in the Westinghouse-Designed Sold State Protection System (7 March 1985)
- Information Notice 1985-19, Alleged Falsification of Certifications and Alteration of Markings on Piping, Valves, and Fittings (11 March 1985)
- Information Notice 1985-20, Motor-Operated Valve Failures Due to Hampering Effect (12 March 1985)
- Information Notice 1985-21, Main Steam Isolation Valve Closure Logic (18 March 1985)
- Information Notice 1985-22, Failure of Limitorque Motor-Operated Valves Resulting from Incorrect Installation of Pinion Gear (21 March 1985)
- Information Notice 1985-23, Inadequate Surveillance and Postmaintenance and Postmodification System Testing (22 March 1985)
- Information Notice 1985-24, Failures of Protective Coatings in Pipes and Heat Exchangers (26 March 1985, Topic: Ultimate heat sink, Coatings)
- Information Notice 1985-25, Consideration of Thermal Conditions in the Design and Installation of Supports for Diesel Generator Exhaust Silencers (2 April 1985, Topic: Coatings)
- Information Notice 1985-26, Vacuum Relief System for Boiling Water Reactor Mark I and Mark II Containments (2 April 1985, Topic: Coatings)
- Information Notice 1985-27, Notifications to the NRC Operations Center and Reporting Events in Licensee Event Reports (3 April 1985, Topic: Coatings)
- Information Notice 1985-28, Partial Loss of AC Power and Diesel Generator Degradation (9 April 1985, Topic: Coatings, Overspeed trip)
- Information Notice 1985-30, Microbiologically Induced Corrosion of Containment Service Water System (19 April 1985, Topic: Hydrostatic, Coatings, Biofouling)
- Information Notice 1985-31, Buildup of Enriched Uranium in Ventilation Ducts and Associated Effluent Treatment Systems (19 April 1985, Topic: Coatings)
- Information Notice 1985-32, Recent Engine Failures of Emergency Diesel Generators (22 April 1985, Topic: Coatings)
- Information Notice 1985-33, Undersized Nozzle-To-Shell Welded Joints in Tanks and Heat Exchangers Constructed Under the Rules of the ASME Boiler and Pressure Vessel Code (22 April 1985)
- Information Notice 1985-34, Heat Tracing Contributes to Corrosion Failure of Stainless Steel Piping (30 April 1985, Topic: Hydrostatic)
- Information Notice 1985-35, Failure of Air Check Valves to Seat (30 April 1985)
- Information Notice 1985-35, Failure of Air Check Valves To Seat (30 April 1985)
- Information Notice 1985-37, Chemical Cleaning of Steam Generators at Millstone 2 (14 May 1985, Topic: Feedwater Heater, Eddy Current Testing)
- Information Notice 1985-38, Loose Parts Obstruct Control Rod Drive Mechanism (21 May 1985)
- Information Notice 1985-39, Auditability of Electrical Equipment Qualification Records at Licensees' Facilities (22 May 1985)
- Information Notice 1985-40, Deficiencies in Equipment Qualification Testing and Certification Process (22 May 1985)
- Information Notice 1985-43, Radiography Events at Power Reactors (30 May 1985, Topic: High Radiation Area, Scaffolding)
- Information Notice 1985-44, Emergency Communication System Monthly Test (30 May 1985, Topic: Health Physics Network)
- Information Notice 1985-46, Clarification of Several Aspects of Removable Radioactive Surface Contamination Limits for Transport Packages (10 June 1985)
- Information Notice 1985-47, Potential Effect of Line-Induced Vibration on Certain Target Rock Solenoid-Operated Valves (18 June 1985)
- Information Notice 1985-48, Respirator Users Notice: Defective Self Contained Breathing Apparatus Air Cylinders (19 June 1985, Topic: Hydrostatic)
- Information Notice 1985-49, Relay Calibration Problem (1 July 1985)
- Information Notice 1985-50, Complete Loss of Main and Auxiliary Feedwater at a PWR Designed by Babcock & Wilcox (8 July 1985, Topic: Overspeed trip)
- Information Notice 1985-51, Inadvertent Loss or Improper Actuation of Safety-Related Equipment (10 July 1985)
- Information Notice 1985-52, Errors in Dose Assessment Computer Codes and Reporting Requirements Under 10 CFR Part 21 (10 July 1985)
- Information Notice 1985-53, Performance of NRC-Licensed Individuals While on Duty (12 July 1985)
- Information Notice 1985-54, Teletherapy Unit Malfunction (15 July 1985)
... further results |
---|