IR 05000482/2022403

From kanterella
Jump to navigation Jump to search
NRC Security Baseline Inspection Report 05000482/2022403
ML22238A145
Person / Time
Site: Wolf Creek Wolf Creek Nuclear Operating Corporation icon.png
Issue date: 08/31/2022
From: Ray Kellar
NRC/RGN-IV/DRSS/PSB
To: Reasoner C
Wolf Creek
Kellar R
References
IR 2022403
Download: ML22238A145 (8)


Text

August 31, 2022

SUBJECT:

WOLF CREEK GENERATING STATION - NRC SECURITY BASELINE INSPECTION REPORT 05000482/2022403

Dear Mr. Reasoner:

On July 22, 2022, the U.S. Nuclear Regulatory Commission (NRC) completed an inspection at Wolf Creek Generating Station. After reviewing additional information provided from your staff, the results of this inspection were discussed with Mr. M. Boyce, Vice President, Engineering, and other members of your staff on August 10, 2022. The results of this inspection are documented in the enclosed report.

No findings or violations of more than minor significance were identified during this inspection.

This letter, its enclosure, and your response (if any) will be made available for public inspection and copying at http://www.nrc.gov/reading-rm/adams.html and at the NRC Public Document Room in accordance with Title 10 of the Code of Federal Regulations 2.390, Public Inspections, Exemptions, Requests for Withholding.

Sincerely, Ray L. Kellar, P.E., Chief Physical Security Branch Division of Radiological Safety and Security Docket No. 05000482 License No. NPF-42

Enclosure:

As stated

Inspection Report

Docket Number:

05000482

License Number:

NPF-42

Report Number:

05000482/2022403

Enterprise Identifier:

I-2022-403-0010

Licensee:

Wolf Creek Nuclear Operating Corp.

Facility:

Wolf Creek Nuclear Generating Station

Location:

Burlington, KS

Inspection Dates:

July 18, 2022 to August 10, 2022

Inspectors:

J. Buchanan, Physical Security Inspector

C. Jewett, Physical Security Inspector

Approved By:

Ray L. Kellar, P.E., Chief

Physical Security Branch

Division of Radiological Safety and Security

SUMMARY

The U.S. Nuclear Regulatory Commission (NRC) continued monitoring the licensees performance by conducting a security baseline inspection at Wolf Creek Nuclear Generating Station, in accordance with the Reactor Oversight Process. The Reactor Oversight Process is the NRCs program for overseeing the safe operation of commercial nuclear power reactors.

Refer to https://www.nrc.gov/reactors/operating/oversight.html for more information.

List of Findings and Violations

No findings or violations of more than minor significance were identified.

Additional Tracking Items

None.

INSPECTION SCOPES

Inspections were conducted using the appropriate portions of the inspection procedures (IPs) in effect at the beginning of the inspection unless otherwise noted. Currently approved IPs with their attached revision histories are located on the public website at http://www.nrc.gov/reading-rm/doc-collections/insp-manual/inspection-procedure/index.html. Samples were declared complete when the IP requirements most appropriate to the inspection activity were met consistent with Inspection Manual Chapter (IMC) 2201, Security Inspection Program for Commercial Nuclear Power Reactors. The inspectors reviewed selected procedures and records, observed activities, and interviewed personnel to assess licensee performance and compliance with Commission rules and regulations, license conditions, site procedures, and standards.

SAFEGUARDS

71130.04 - Equipment Performance, Testing, and Maintenance

The inspectors evaluated the security equipment testing and maintenance program. The following elements were evaluated from this IP dated [date].

Equipment Performance, Testing, and Maintenance (1 Sample)

(1) Tier I: All requirements.

Tier II: All requirements.

Tier III: All requirements.

71130.07 - Security Training

The inspectors evaluated the security training program through completion of the following

procedure elements: Security Training

(1) Tier I: All Requirements

Tier II: All Requirements

Tier III: All Requirements except 02.12 a - b

INSPECTION RESULTS

No findings were identified.

EXIT MEETINGS AND DEBRIEFS

The inspectors verified no proprietary information was retained or documented in this report.

On August 10, 2022, the inspectors presented the security baseline inspection results to Mr. M. Boyce, Vice President, Engineering, and other members of the licensee staff.

DOCUMENTS REVIEWED

Inspection

Procedure

Type

Designation

Description or Title

Revision or

Date

Corrective Action

Documents

144232,

144233,

10007572,

10008781,

10011331,

10011871,

10011892,

10012014,

10012384,

10013910,

10014215,

10014628,

10014684,

10015088,

10015257,

10015258,

10015372, and

10015374

Corrective Action

Documents

Resulting from

Inspection

10016146,

10016199,

10016200,

10016202, and

10016203

Intrusion Alarm History Report

07/21/2022

OJT Evaluator Guide, Task 08 - Conduct Security Patrols

Weekly Device Test Log

06/01/2022

thru

07/30/2022

Protected Area IDS Test Log

06/06/2022

Armorer's Inspections Desk Top Instructions

10/21/2020

71130.04

Miscellaneous

Wolf Creek Security Plan, Training and Qualification Plan,

Safeguards Contingency Plan and Independent Spent Fuel

Inspection

Procedure

Type

Designation

Description or Title

Revision or

Date

Storage Installation Security Program

Personnel Security Equipment Quarterly Inspection

22

OF1700300

Lesson Plan, Conduct Searches

AI 27-006

Safety/Security Interface

AP 27-005A

Cargo Search

AP 28A-100

Corrective Action Program

26A

SEC 01-101

Security Equipment Issue

SEC 01-108A

Security System Performance Testing

SEC 01-129

Armed Response Team Duties

6A

SEC 50-127A

Security Condition/Hostile Action

Procedures

SEC 50-130A

Compensatory Requirements

22-71130.04

03/17/2022

Self-Assessments

21-01-SC/CS

Quality Assurance Audit Report

03/17/2021

20-463923-000

Security Emergency Diesel Generator

21-469400-000

Security Emergency Diesel Generator

10/04/2021

21-470182-000

Generator, 350 KW, Diesel, Main Access Facility

10/21/2021

21-474244-000

01/10/2022

21-475548-000

Battery Cabinet #1 F UPS CQ001

03/07/2022

21-475808-000

Backup Battery for 900 MHZ Trunked Radio System, Lead

Calcium, 1.215 Spec. Gravity, 2.20 V Cell Float, 2.33 V Cell

Max, 304 LBS Cell

03/21/2022

21-475829-000

03/28/2022

21-476011-001

04/25/2022

21-476011-002

04/18/2022

21-476446-000

Battery Cabinet #1 F UPS CQ001

05/02/2022

2-477143-000

Security System Weekly PM

06/14/2022

Work Orders

2-477343-000

Security System Weekly PM

06/21/2022

71130.07

Corrective Action

Documents

00072627,

00143571,

00145186,

10002181,

10014521,

10015561,

Inspection

Procedure

Type

Designation

Description or Title

Revision or

Date

10015564,

10015741,

10015807

Corrective Action

Documents

Resulting from

Inspection

10016192,

10016204,

10016218

OF0100600

Tampering And Sabotage

005

OF1700300

Conduct Searches

016

OF1700500

CONDUCT COMMUNICATIONS

007

OF1701400

TACTICAL TRAINING

003

Miscellaneous

OF1703000

Wolf Creek Security Bearcat Program

2

AI 30E-005

Instructor Qualification Requirements

AP 15C-004

Preparation, Review, and Approval of Procedures, Inst., and

Forms

55A

AP 27-002

Security Plan and Procedures

SEC 01-400

Preparation of Security Lesson Plan

SEC 01-401

Security Personnel Critical Tasks

SEC 01-402

Security Personnel Training and Qualification

SEC 01-403

Security Personnel Medical Qualifications

31A

SEC 01-411

Tactical Drill and Force on Force Tactical Exercise Program

11A

SEC 01-411

Tactical Drill and Force on Force Tactical Exercise Program

SEC 01-412

Security On-Shift Drills

SEC 01-413

Security Training Feedback Program

SEC 01-415

Systematic Approach to Training

Procedures

SEC 50-123A

Security Off-Normal Procedure

Self-Assessments

QH-2022-2327

NRC Security Baseline Inspection Readiness Assessment

Checklist

IP 71130.07, Security Training

03/10/2022